Sample records for storage unit mixed

  1. Red cell storage in E-Sol 5 and Adsol additive solutions: paired comparison using mixed and non-mixed study designs.

    PubMed

    Radwanski, K; Thill, M; Min, K

    2014-05-01

    If transfusion of older stored red cells is found to negatively affect clinical outcome, one possible alternative to shortened outdate is the use of new additive solutions (AS) that ameliorate the storage lesion. Erythro-Sol (E-Sol), a previously developed next-generation AS, has been reformulated into E-Sol 5, which is compatible with current anticoagulants and AS volumes. The effect of E-Sol 5 on red cells during storage compared to current AS has not been reported. Paired, ABO-matched whole-blood units were collected into CPD anticoagulant, pooled, split and processed into plasma and red cell units with either 110 ml of Adsol or 105 ml of E-Sol 5 within 8 h of collection. In Study 1, paired units in E-Sol 5 and Adsol were sampled on Day 0 and every 7 days up to Day 42 (n = 10). In Study 2, paired units in E-Sol 5 and Adsol were sampled only on Day 0 and Day 42 (n = 10). In Study 1, 2,3 DPG levels were maintained until Day 28 in E-Sol 5 units and Day 14 in Adsol units. ATP levels were higher in E-Sol 5 units until Day 21, after which they were comparable between the two groups. In both studies, metabolic activity was greater in E-Sol 5 units with respect to glucose consumption and lactate production. Morphology scores were higher, and haemolysis and microparticles generated were lower in E-Sol 5 vs. Adsol units. Weekly mixing of units lowered haemolysis and microparticle levels and increased potassium content on Day 42 in both additive solutions. Regardless of whether units are mixed weekly or are stored non-mixed, E-Sol 5 slows the progression of the red cell storage lesion and improves the overall in vitro quality of RBC throughout storage. © 2013 International Society of Blood Transfusion.

  2. SSH2S: Hydrogen storage in complex hydrides for an auxiliary power unit based on high temperature proton exchange membrane fuel cells

    NASA Astrophysics Data System (ADS)

    Baricco, Marcello; Bang, Mads; Fichtner, Maximilian; Hauback, Bjorn; Linder, Marc; Luetto, Carlo; Moretto, Pietro; Sgroi, Mauro

    2017-02-01

    The main objective of the SSH2S (Fuel Cell Coupled Solid State Hydrogen Storage Tank) project was to develop a solid state hydrogen storage tank based on complex hydrides and to fully integrate it with a High Temperature Proton Exchange Membrane (HT-PEM) fuel cell stack. A mixed lithium amide/magnesium hydride system was used as the main storage material for the tank, due to its high gravimetric storage capacity and relatively low hydrogen desorption temperature. The mixed lithium amide/magnesium hydride system was coupled with a standard intermetallic compound to take advantage of its capability to release hydrogen at ambient temperature and to ensure a fast start-up of the system. The hydrogen storage tank was designed to feed a 1 kW HT-PEM stack for 2 h to be used for an Auxiliary Power Unit (APU). A full thermal integration was possible thanks to the high operation temperature of the fuel cell and to the relative low temperature (170 °C) for hydrogen release from the mixed lithium amide/magnesium hydride system.

  3. Hydrogen storage and integrated fuel cell assembly

    DOEpatents

    Gross, Karl J.

    2010-08-24

    Hydrogen is stored in materials that absorb and desorb hydrogen with temperature dependent rates. A housing is provided that allows for the storage of one or more types of hydrogen-storage materials in close thermal proximity to a fuel cell stack. This arrangement, which includes alternating fuel cell stack and hydrogen-storage units, allows for close thermal matching of the hydrogen storage material and the fuel cell stack. Also, the present invention allows for tailoring of the hydrogen delivery by mixing different materials in one unit. Thermal insulation alternatively allows for a highly efficient unit. Individual power modules including one fuel cell stack surrounded by a pair of hydrogen-storage units allows for distribution of power throughout a vehicle or other electric power consuming devices.

  4. Method and apparatus for operating an improved thermocline storage unit

    DOEpatents

    Copeland, R.J.

    1982-09-30

    A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer there between. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.

  5. Method and apparatus for operating an improved thermocline storage unit

    DOEpatents

    Copeland, Robert J.

    1985-01-01

    A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer therebetween. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.

  6. Associate Directorate Environmental Management Infrastructure Plan for Area G and Area L Domes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, Patrice Ann; Baumer, Andrew Ronald

    Technical Area 54, at Los Alamos National Laboratory (LANL) is situated in the east-central portion of the Laboratory on the Mesita del Buey between Pajarito Canyon to the south and Cañada del Buey to the north. TA-54 includes four MDAs designated as G, H, J, and L; a waste characterization, container storage, and transfer facility; active TRU waste and MLLW waste storage and low-level waste (LLW) disposal operations at Area G; active hazardous and mixed low-level (MLLW) waste storage operations at Area L; and administrative and support areas. MDA J has previously under-gone closure. Area G is a waste managementmore » and disposal area, used for the disposal and storage of radioactive wastes since 1957. Since August 2015, Area G has been in warm standby and provides minimal operations to support safety, compliance, and nitrate salt remediation. Located within Area G, MDA G covers 63-acres. MDA G contains 334 active and inactive waste management units, which include 36 pits, 294 shafts, and 4 trenches. In 1971, Area G began use for the retrievable storage of TRU waste. There are two pits, four trenches and 60 shafts that contain retrievable TRU waste. Thirty-three of the shafts contain TRU waste that may present unique problems for retrieval. In 1986, segregation of MLLW was initiated at Area G for treatment and temporary storage or for off-site disposal. Area G is the only active LLW disposal facility at the Laboratory. Current operations at Area G include storage and characterization of TRU and mixed TRU waste destined for off-site disposal at the Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico and the storage of MLLW destined for off-site treatment and/or disposal. Several above-ground container storage units (CSUs) are currently used for storage of containerized MLLW and/or mixed TRU wastes. These consist of asphalt pads and associated fabric domes or other structures. As defined by the Consent Order, MDA G contains 229 of the 334 subsurface waste management units at Area G. These MDA G disposal units include 32 pits, 193 shafts, and 4 trenches and contain LLW, MLLW and TRU waste. The remaining 105 solid waste management units (SWMUs) include RCRA-regulated landfill and storage units and DOE-regulated LLW disposal units. The TA-54 closure project must ensure that continuing waste operations at Area G and their transition to an interim or enduring facility are coordinated with closure activities.« less

  7. Waste Encapsulation and Storage Facility (WESF) Dangerous Waste Training Plan (DWTP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SIMMONS, F.M.

    2000-03-29

    This Waste Encapsulation Storage Facility (WESF) Dangerous Waste Training Plan (DWTP) applies to personnel who perform work at, or in support of WESF. The plan, along with the names of personnel, may be given to a regulatory agency inspector upon request. General workers, subcontractors, or visiting personnel who have not been trained in the management of dangerous wastes must be accompanied by an individual who meets the requirements of this training plan. Dangerous waste management includes handling, treatment, storage, and/or disposal of dangerous and/or mixed waste. Dangerous waste management units covered by this plan include: less-than-90-day accumulation area(s); pool cellsmore » 1-8 and 12 storage units; and process cells A-G storage units. This training plan describes general requirements, worker categories, and provides course descriptions for operation of the WESF permitted miscellaneous storage units and the Less-than-90-Day Accumulation Areas.« less

  8. Fixed-speed and Variable-speed Pumped Storage Dispatch Model in Power Systems with High Renewable Penetration

    NASA Astrophysics Data System (ADS)

    Yuan, Bo; Zong, Jin; Xu, Zhicheng

    2018-06-01

    According to different operating characteristics of pumped storage fixed speed unit and variable speed unit, a joint dispatching model of pumped storage unit and other types of units based on mixed integer linear optimization is constructed. The model takes into account the operating conditions, reservoir capacity, cycle type and other pumped storage unit constraints, but also consider the frequent start and stop and the stability of the operation of the unit caused by the loss. Using the Cplex solver to solve the model, the empirical example of the provincial power grid shows that the model can effectively arrange the pumping storage speed and the dispatching operation of the variable speed unit under the precondition of economic life of the unit, and give full play to the function of peak shaving and accommodating new energy. Because of its more flexible regulation characteristics of power generation and pumping conditions, the variable speed unit can better improve the operating conditions of other units in the system and promote the new energy dissipation.

  9. Magma volumes and storage in the middle crust

    NASA Astrophysics Data System (ADS)

    Memeti, V.; Barnes, C. G.; Paterson, S. R.

    2015-12-01

    Quantifying magma volumes in magma plumbing systems is mostly done through geophysical means or based on volcanic eruptions. Detailed studies of plutons, however, are useful in revealing depths and evolving volumes of stored magmas over variable lifetimes of magma systems. Knowledge of the location, volume, and longevity of stored magma is critical for understanding where in the crust magmas attain their chemical signature, how these systems physically behave and how source, storage levels, and volcanoes are connected. Detailed field mapping, combined with single mineral geochemistry and geochronology of plutons, allow estimates of size and longevity of melt-interconnected magma batches that existed during the construction of magma storage sites. The Tuolumne intrusive complex (TIC) recorded a 10 myr magmatic history. Detailed maps of the major units in different parts of the TIC indicate overall smaller scale (cm- to <1 km) compositional variation in the oldest, outer Kuna Crest unit and mainly larger scale (>10 km) changes in the younger Half Dome and Cathedral Peak units. Mineral-scale trace element data from hornblende of granodiorites to gabbros from the Kuna Crest lobe show distinct hornblende compositions and zoning patterns. Mixed hornblende populations occur only at the transition to the main TIC. This compositional heterogeneity in the first 1-2 myr points to low volume magmatism resulting in smaller, discrete and not chemically interacting magma bodies. Trace element and Sr- and Pb-isotope data from growth zones of K-feldspar phenocrysts from the two younger granodiorites indicate complex mineral zoning, but general isotopic overlap, suggesting in-situ, inter-unit mixing and fractionation. This is supported by hybrid zones between units, mixing of zircon, hornblende, and K-feldspar populations and late leucogranites. Thus, magma body sizes increased later resulting in overall more homogeneous, but complexly mixing magma mushes that fractionated locally.

  10. Storage dynamics in hydropedological units control hillslope connectivity, runoff generation, and the evolution of catchment transit time distributions

    PubMed Central

    Tetzlaff, D; Birkel, C; Dick, J; Geris, J; Soulsby, C

    2014-01-01

    We examined the storage dynamics and isotopic composition of soil water over 12 months in three hydropedological units in order to understand runoff generation in a montane catchment. The units form classic catena sequences from freely draining podzols on steep upper hillslopes through peaty gleys in shallower lower slopes to deeper peats in the riparian zone. The peaty gleys and peats remained saturated throughout the year, while the podzols showed distinct wetting and drying cycles. In this region, most precipitation events are <10 mm in magnitude, and storm runoff is mainly generated from the peats and peaty gleys, with runoff coefficients (RCs) typically <10%. In larger events the podzolic soils become strongly connected to the saturated areas, and RCs can exceed 40%. Isotopic variations in precipitation are significantly damped in the organic-rich soil surface horizons due to mixing with larger volumes of stored water. This damping is accentuated in the deeper soil profile and groundwater. Consequently, the isotopic composition of stream water is also damped, but the dynamics strongly reflect those of the near-surface waters in the riparian peats. “pre-event” water typically accounts for >80% of flow, even in large events, reflecting the displacement of water from the riparian soils that has been stored in the catchment for >2 years. These riparian areas are the key zone where different source waters mix. Our study is novel in showing that they act as “isostats,” not only regulating the isotopic composition of stream water, but also integrating the transit time distribution for the catchment. Key Points Hillslope connectivity is controlled by small storage changes in soil units Different catchment source waters mix in large riparian wetland storage Isotopes show riparian wetlands set the catchment transit time distribution PMID:25506098

  11. Storage dynamics in hydropedological units control hillslope connectivity, runoff generation, and the evolution of catchment transit time distributions.

    PubMed

    Tetzlaff, D; Birkel, C; Dick, J; Geris, J; Soulsby, C

    2014-02-01

    We examined the storage dynamics and isotopic composition of soil water over 12 months in three hydropedological units in order to understand runoff generation in a montane catchment. The units form classic catena sequences from freely draining podzols on steep upper hillslopes through peaty gleys in shallower lower slopes to deeper peats in the riparian zone. The peaty gleys and peats remained saturated throughout the year, while the podzols showed distinct wetting and drying cycles. In this region, most precipitation events are <10 mm in magnitude, and storm runoff is mainly generated from the peats and peaty gleys, with runoff coefficients (RCs) typically <10%. In larger events the podzolic soils become strongly connected to the saturated areas, and RCs can exceed 40%. Isotopic variations in precipitation are significantly damped in the organic-rich soil surface horizons due to mixing with larger volumes of stored water. This damping is accentuated in the deeper soil profile and groundwater. Consequently, the isotopic composition of stream water is also damped, but the dynamics strongly reflect those of the near-surface waters in the riparian peats. "pre-event" water typically accounts for >80% of flow, even in large events, reflecting the displacement of water from the riparian soils that has been stored in the catchment for >2 years. These riparian areas are the key zone where different source waters mix. Our study is novel in showing that they act as "isostats," not only regulating the isotopic composition of stream water, but also integrating the transit time distribution for the catchment. Hillslope connectivity is controlled by small storage changes in soil unitsDifferent catchment source waters mix in large riparian wetland storageIsotopes show riparian wetlands set the catchment transit time distribution.

  12. The impact of biopreservatives and storage temperature in the quality and safety of minimally processed mixed vegetables for soup.

    PubMed

    Alvarez, María V; Ponce, Alejandra G; Mazzucotelli, Cintia A; Moreira, María R

    2015-03-30

    The combined effects of bioactive agents (tea tree essential oil, propolis extract and gallic acid) and storage temperature on the microbiological and sensory quality of fresh-cut mixed vegetables for soup (celery, leek and butternut squash) were studied with the objective of preserving its quality and safety. Refrigeration temperature was confirmed as the main factor to limit the growth of spoilage and pathogenic microorganisms. Biopreservatives applied on mixed vegetables were effective only when combined with optimal refrigeration temperature (5 °C). Bioactive compounds showed slight effectiveness in controlling the microbiota present in mixed vegetables, although coliforms were greatly reduced by gallic acid and propolis treatments, achieving 0.5-2 log unit reductions during storage. Also, these agents showed antimicrobial activity against endogenous Escherichia coli and inoculated E. coli O157:H7, exerting a bacteriostatic effect and reducing population counts by 0.9-1.2 log CFU g(-1) at 10 days of refrigerated storage. The combination of propolis treatment with refrigerated storage conditions effectively preserved the sensory quality and prolonged the sensory shelf life of fresh-cut mixed vegetables by 3 days. The use of natural agents such as propolis extract to preserve the quality and safety of mixed vegetables for soup might be an interesting option to address the concerns of the consumer about the use of synthetic chemical antimicrobials potentially harmful to health. © 2014 Society of Chemical Industry.

  13. 1998 report on Hanford Site land disposal restrictions for mixed waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, D.G.

    1998-04-10

    This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-01H. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility. The US Department of Energy, its predecessors, and contractors on the Hanford Facility were involved in the production and purification of nuclear defense materials from the early 1940s to the late 1980s. These production activities have generated large quantities of liquid and solid mixed waste. This waste is regulated under authority of bothmore » the Resource Conservation and Recovery Act of l976 and the Atomic Energy Act of 1954. This report covers only mixed waste. The Washington State Department of Ecology, US Environmental Protection Agency, and US Department of Energy have entered into the Tri-Party Agreement to bring the Hanford Facility operations into compliance with dangerous waste regulations. The Tri-Party Agreement required development of the original land disposal restrictions (LDR) plan and its annual updates to comply with LDR requirements for mixed waste. This report is the eighth update of the plan first issued in 1990. The Tri-Party Agreement requires and the baseline plan and annual update reports provide the following information: (1) Waste Characterization Information -- Provides information about characterizing each LDR mixed waste stream. The sampling and analysis methods and protocols, past characterization results, and, where available, a schedule for providing the characterization information are discussed. (2) Storage Data -- Identifies and describes the mixed waste on the Hanford Facility. Storage data include the Resource Conservation and Recovery Act of 1976 dangerous waste codes, generator process knowledge needed to identify the waste and to make LDR determinations, quantities stored, generation rates, location and method of storage, an assessment of storage-unit compliance status, storage capacity, and the bases and assumptions used in making the estimates.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Management

    The proposed Mixed Waste Storage Unit (MWSU) will be located within the Area 5 Radioactive Waste Management Complex (RWMC). Existing facilities at the RWMC will be used to store low-level mixed waste (LLMW). Storage is required to accommodate offsite-generated LLMW shipped to the Nevada Test Site (NTS) for disposal in the new Mixed Waste Disposal Unit (MWDU) currently in the design/build stage. LLMW generated at the NTS (onsite) is currently stored on the Transuranic (TRU) Pad (TP) in Area 5 under a Mutual Consent Agreement (MCA) with the Nevada Division of Environmental Protection, Bureau of Federal Facilities (NDEP/BFF). When themore » proposed MWSU is permitted, the U.S. Department of Energy (DOE) will ask that NDEP revoke the MCA and onsite-generated LLMW will fall under the MWSU permit terms and conditions. The unit will also store polychlorinated biphenyl (PCB) waste and friable and non-friable asbestos waste that meets the acceptance criteria in the Waste Analysis Plan (Exhibit 2) for disposal in the MWDU. In addition to Resource Conservation and Recovery Act (RCRA) requirements, the proposed MWSU will also be subject to Department of Energy (DOE) orders and other applicable state and federal regulations. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational RCRA units at the NTS and their respective regulatory status.« less

  15. The mixed low-level waste problem in BE/NWN capsule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, D.C.

    1999-07-01

    The Boh Environmental, LLC (BE) and Northwest Nuclear, LLC (NWN) program addresses the problem of diminishing capacity in the United States to store mixed waste. A lack of an alternative program has caused the US Department of Energy (DOE) to indefinitely store all of its mixed waste in Resource Conservation and Recovery Act (RCRA) compliant storage facilities. Unfortunately, this capacity is fast approaching the administrative control limit. The combination of unique BE encapsulation and NWN waste characterization technologies provides an effective solution to DOE's mixed-waste dilemma. The BE ARROW-PAK technique encapsulates mixed low-level waste (MLLW) in extra-high molecular weight, high-densitymore » polyethylene, pipe-grade resin cylinders. ARROW-PAK applications include waste treatment, disposal, transportation (per 49 CFR 173), vault encasement, and interim/long-term storage for 100 to 300 yr. One of the first demonstrations of this treatment/storage technique successfully treated 880 mixed-waste debris drums at the DOE Hanford Site in 1997. NWN, deploying the APNea neutron assay technology, provides the screening and characterization capability necessary to ensure that radioactive waste is correctly categorized as either transuranic (TRU) or LLW. MLLW resulting from D and D activities conducted at the Oak Ridge East Tennessee Technology Park will be placed into ARROW-PAK containers following comprehensive characterization of the waste by NWN. The characterized and encapsulated waste will then be shipped to a commercial disposal facility, where the shipments meet all waste acceptance criteria of the disposal facility including treatment criteria.« less

  16. Characterization of 618-11 solid waste burial ground, disposed waste, and description of the waste generating facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hladek, K.L.

    1997-10-07

    The 618-11 (Wye or 318-11) burial ground received transuranic (TRTJ) and mixed fission solid waste from March 9, 1962, through October 2, 1962. It was then closed for 11 months so additional burial facilities could be added. The burial ground was reopened on September 16, 1963, and continued operating until it was closed permanently on December 31, 1967. The burial ground received wastes from all of the 300 Area radioactive material handling facilities. The purpose of this document is to characterize the 618-11 solid waste burial ground by describing the site, burial practices, the disposed wastes, and the waste generatingmore » facilities. This document provides information showing that kilogram quantities of plutonium were disposed to the drum storage units and caissons, making them transuranic (TRU). Also, kilogram quantities of plutonium and other TRU wastes were disposed to the three trenches, which were previously thought to contain non-TRU wastes. The site burial facilities (trenches, caissons, and drum storage units) should be classified as TRU and the site plutonium inventory maintained at five kilograms. Other fissile wastes were also disposed to the site. Additionally, thousands of curies of mixed fission products were also disposed to the trenches, caissons, and drum storage units. Most of the fission products have decayed over several half-lives, and are at more tolerable levels. Of greater concern, because of their release potential, are TRU radionuclides, Pu-238, Pu-240, and Np-237. TRU radionuclides also included slightly enriched 0.95 and 1.25% U-231 from N-Reactor fuel, which add to the fissile content. The 618-11 burial ground is located approximately 100 meters due west of Washington Nuclear Plant No. 2. The burial ground consists of three trenches, approximately 900 feet long, 25 feet deep, and 50 feet wide, running east-west. The trenches constitute 75% of the site area. There are 50 drum storage units (five 55-gallon steel drums welded together) buried in three rows in the northeast comer. In addition, five eight-foot diameter caissons are located at the west end of the center row of the drum storage units. Initially, wastes disposed to the caissons and drum storage units were from the 325 and 327 building hot cells. Later, a small amount of remote-handled (RH) waste from the 309 building Plutonium Recycle Test Reactor (PRTR) cells, and the newly built 324 building hot cells, was disposed at the site.« less

  17. Capillary Trapping of CO2 in Oil Reservoirs: Observations in a Mixed-Wet Carbonate Rock.

    PubMed

    Al-Menhali, Ali S; Krevor, Samuel

    2016-03-01

    Early deployment of carbon dioxide storage is likely to focus on injection into mature oil reservoirs, most of which occur in carbonate rock units. Observations and modeling have shown how capillary trapping leads to the immobilization of CO2 in saline aquifers, enhancing the security and capacity of storage. There are, however, no observations of trapping in rocks with a mixed-wet-state characteristic of hydrocarbon-bearing carbonate reservoirs. Here, we found that residual trapping of supercritical CO2 in a limestone altered to a mixed-wet state with oil was significantly less than trapping in the unaltered rock. In unaltered samples, the trapping of CO2 and N2 were indistinguishable, with a maximum residual saturation of 24%. After the alteration of the wetting state, the trapping of N2 was reduced, with a maximum residual saturation of 19%. The trapping of CO2 was reduced even further, with a maximum residual saturation of 15%. Best-fit Land-model constants shifted from C = 1.73 in the water-wet rock to C = 2.82 for N2 and C = 4.11 for the CO2 in the mixed-wet rock. The results indicate that plume migration will be less constrained by capillary trapping for CO2 storage projects using oil fields compared with those for saline aquifers.

  18. Short-term bulk energy storage system scheduling for load leveling in unit commitment: modeling, optimization, and sensitivity analysis

    PubMed Central

    Hemmati, Reza; Saboori, Hedayat

    2016-01-01

    Energy storage systems (ESSs) have experienced a very rapid growth in recent years and are expected to be a promising tool in order to improving power system reliability and being economically efficient. The ESSs possess many potential benefits in various areas in the electric power systems. One of the main benefits of an ESS, especially a bulk unit, relies on smoothing the load pattern by decreasing on-peak and increasing off-peak loads, known as load leveling. These devices require new methods and tools in order to model and optimize their effects in the power system studies. In this respect, this paper will model bulk ESSs based on the several technical characteristics, introduce the proposed model in the thermal unit commitment (UC) problem, and analyze it with respect to the various sensitive parameters. The technical limitations of the thermal units and transmission network constraints are also considered in the model. The proposed model is a Mixed Integer Linear Programming (MILP) which can be easily solved by strong commercial solvers (for instance CPLEX) and it is appropriate to be used in the practical large scale networks. The results of implementing the proposed model on a test system reveal that proper load leveling through optimum storage scheduling leads to considerable operation cost reduction with respect to the storage system characteristics. PMID:27222741

  19. Short-term bulk energy storage system scheduling for load leveling in unit commitment: modeling, optimization, and sensitivity analysis.

    PubMed

    Hemmati, Reza; Saboori, Hedayat

    2016-05-01

    Energy storage systems (ESSs) have experienced a very rapid growth in recent years and are expected to be a promising tool in order to improving power system reliability and being economically efficient. The ESSs possess many potential benefits in various areas in the electric power systems. One of the main benefits of an ESS, especially a bulk unit, relies on smoothing the load pattern by decreasing on-peak and increasing off-peak loads, known as load leveling. These devices require new methods and tools in order to model and optimize their effects in the power system studies. In this respect, this paper will model bulk ESSs based on the several technical characteristics, introduce the proposed model in the thermal unit commitment (UC) problem, and analyze it with respect to the various sensitive parameters. The technical limitations of the thermal units and transmission network constraints are also considered in the model. The proposed model is a Mixed Integer Linear Programming (MILP) which can be easily solved by strong commercial solvers (for instance CPLEX) and it is appropriate to be used in the practical large scale networks. The results of implementing the proposed model on a test system reveal that proper load leveling through optimum storage scheduling leads to considerable operation cost reduction with respect to the storage system characteristics.

  20. 303-K Storage Facility closure plan. Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-12-15

    Recyclable scrap uranium with zircaloy-2 and copper silicon alloy, uranium-titanium alloy, beryllium/zircaloy-2 alloy, and zircaloy-2 chips and fines were secured in concrete billets (7.5-gallon containers) in the 303-K Storage Facility, located in the 300 Area. The beryllium/zircaloy-2 alloy and zircaloy-2 chips and fines are designated as mixed waste with the characteristic of ignitability. The concretion process reduced the ignitability of the fines and chips for safe storage and shipment. This process has been discontinued and the 303-K Storage Facility is now undergoing closure as defined in the Resource Conservation and Recovery Act (RCRA) of 1976 and the Washington Administrative Codemore » (WAC) Dangerous Waste Regulations, WAC 173-303-040. This closure plan presents a description of the 303-K Storage Facility, the history of materials and waste managed, and the procedures that will be followed to close the 303-K Storage Facility. The 303-K Storage Facility is located within the 300-FF-3 (source) and 300-FF-5 (groundwater) operable units, as designated in the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) (Ecology et al. 1992). Contamination in the operable units 300-FF-3 and 300-FF-5 is scheduled to be addressed through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 remedial action process. Therefore, all soil remedial action at the 304 Facility will be conducted as part of the CERCLA remedial action of operable units 300-FF-3 and 300-FF-5.« less

  1. Preeruption conditions and timing of dacite-andesite magma mixing in the 2.2 ka eruption at Mount Rainier

    NASA Astrophysics Data System (ADS)

    Venezky, D. Y.; Rutherford, M. J.

    1997-01-01

    Analytical, field, and experimental evidence demonstrate that the Mount Rainier tephra layer C (2.2 ka) preserves a magma mixing event between an andesitic magma (whole rock SiO2 content of 57-60 wt %) and a dacitic magma (whole rock SiO2 content of 65±1 wt %). The end-member andesite (a mix of an injected and chamber andesite) and dacite can be characterized on the basis of the homogeneity of the matrix glass and phenocryst rim compositions. Many pumices, however, contain mixtures of the end-members. The end-member dacite contains a microlite-free matrix glass with 74-77 wt % SiO2, orthopyroxene rims of Mg57-64, clinopyroxene rims of Mg66-74, and plagioclase rim anorthite contents of An45-65. The temperature and oxygen fugacity, from Fe-Ti oxide compositions, are 930±10°C and 0.5-0.75 log units above NNO. The mixed andesite contains Mg73-84 orthopyroxene rims, Mg73-78 clinopyroxene rims, An78-84 plagioclase rims, and Mg67-74 amphibole rims. The temperature from Fe-Ti oxides, hornblendeplagioclase, and two-pyroxene geothermometry is 1060±15°C, and the oxygen fugacity is approximately one log unit above NNO for the injected andesite. The chamber andesite is estimated to be a magma with a ˜64-65 wt % SiO2 melt at 980°C and a NNO oxygen fugacity. We conclude that the andesitic and dacitic magmas are from separate magma storage regions (at >7 km and ˜2.4 km) due to differences in the bimodal whole rock, matrix glass, and phenocryst compositions and the presence or absence of stable hornblende. The time involved from the mixing event through the eruption is limited to a period of 4-5 days based on Fe-Ti oxide reequilibration, phenocryst growth rates, and hornblende breakdown. The eruption sequence is interpreted as having been initiated by an injection of the 1060±15°C andesitic magma into the ˜980°C (>7 km) andesite storage region. The mixed andesitic magma then intersected a shallow, ˜2.4 km, dacitic storage system on its way toward the surface. The eruption became more dacitic over time, and the final products some show evidence of partial reequilibration between the andesite and dacite.

  2. Mixing and residence times of stormwater runoff in a detection system

    USGS Publications Warehouse

    Martin, Edward H.

    1989-01-01

    Five tracer runs were performed on a detention pond and wetlands system to determine mixing and residence times in the system. The data indicate that at low discharges and with large amounts of storage, the pond is moderately mixed with residence times not much less than the theoretical maximum possible under complete mixing. At higher discharges and with less storage in the pond, short-circuiting occurs, reducing the amount of mixing in the pond and appreciably reducing the residence times. The time between pond outlet peak concentrations and wetlands outlet peak concentrations indicate that in the wetlands, mixing increases with decreasing discharge and increasing storage.

  3. Prehospital Use of Plasma for Traumatic Hemorrhage

    DTIC Science & Technology

    2014-06-01

    known reagent B- cells o Mix o Spin in centrifuge for 15 seconds o Read for agglutination macroscopically o If agglutination is present, the unit...of days in the hospital, number of days on a ventilator, number of operations, number of infections, and cumulative utilization of blood products...procedure development and the items to be accomplished follow: GOALS:  Safe and adequate delivery, storage, and handover of plasma from Blood

  4. Red blood cell transfusion and increased length of storage are not associated with deep vein thrombosis in medical and surgical critically ill patients: a prospective observational cohort study

    PubMed Central

    2011-01-01

    Introduction With prolonged storage times, cell membranes of red blood cells (RBCs) undergo morphologic and biochemical changes, termed 'RBC storage lesions'. Storage lesions may promote inflammation and thrombophilia when transfused. In trauma patients, RBC transfusion was an independent risk factor for deep vein thrombosis (DVT), specifically when RBC units were stored > 21 days or when 5 or more units were transfused. The objective of this study was to determine if RBC transfusions or RBC storage age predicts incident DVT in medical or surgical intensive care unit (ICU) patients. Methods Using a database which prospectively enrolled 261 patients over the course of 1 year with an ICU stay of at least 3 days, we analyzed DVT and RBC transfusions using Cox proportional hazards regression. Transfusions were analyzed with 4 thresholds, and storage age using 3 thresholds. DVTs were identified by twice-weekly proximal leg ultrasounds. Multivariable analyses were adjusted for 4 significant DVT predictors in this population (venous thrombosis history, chronic dialysis, platelet transfusion and inotropes). Results Of 261 patients, 126 (48.3%) had at least 1 RBC transfusion; 46.8% of those transfused had ≥ 5 units in ICU. Patients receiving RBCs were older (68.8 vs 64.1 years), more likely to be female (47.0 vs 30.7), sicker (APACHEII 26.8 vs 24.4), and more likely to be surgical (21.4 vs 8.9) (P < 0.05). The total number of RBCs per patient was 1-64, mean was 6.3 (SD 7.5), median was 4 (IQR 2,8). In univariate analyses, there was no association between DVT and RBC exposure (1 day earlier, 3 days earlier, 7 days earlier, or ever) or RBC storage (≤ 7 or > 7 days, ≤ 14 or > 14 days, ≤ 21 or > 21 days). Among patients transfused, no multivariable analyses showed that RBC transfusion or storage age predicted DVT. Trends were counter to the hypothesis (e.g., RBC storage for ≤ 7 days suggested a higher DVT risk compared to > 7 days (HR 5.3; 95% CI 1.3-22.1). Conclusions We were unable to detect any association between RBC transfusions or prolonged red cell storage and increased risk of DVT in medical or surgical ICU patients. Alternate explanations include a lack of sufficient events or patients' interaction, between patient groups, a mixing of red cell storage times creating differential effects on DVT risk, and unmeasured confounders. PMID:22044745

  5. Secondary Waste Form Development and Optimization—Cast Stone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundaram, S. K.; Parker, Kent E.; Valenta, Michelle M.

    2011-07-14

    Washington River Protection Services is considering the design and construction of a Solidification Treatment Unit (STU) for the Effluent Treatment Facility (ETF) at Hanford. The ETF is a Resource Conservation and Recovery Act-permitted, multi-waste, treatment and storage unit and can accept dangerous, low-level, and mixed wastewaters for treatment. The STU needs to be operational by 2018 to receive secondary liquid wastes generated during operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The STU to ETF will provide the additional capacity needed for ETF to process the increased volume of secondary wastes expected to be produced by WTP.

  6. Crystallization of Nanocomposite Glasses Made by the SSG Process

    DTIC Science & Technology

    1993-01-12

    thermogravimetric analysis (TGA). The role of glass structure and composition in the thermochemical stability will be discussed. 37 II. EXPERIMENTAL PROCEDLRES The...applications in the materials field. tion and r-plot analysis of this porous nanocomposite showed Because of the nanoscale mixing of inorganic and organic a... nanoparticles in There is a need for substrates with very low relative permit- magnetic recording media can lead to smaller storage units tivitv 1ɛ) in %ery

  7. Experimental Investigation of Jet-Induced Mixing of a Large Liquid Hydrogen Storage Tank

    NASA Technical Reports Server (NTRS)

    Lin, C. S.; Hasan, M. M.; Vandresar, N. T.

    1994-01-01

    Experiments have been conducted to investigate the effect of fluid mixing on the depressurization of a large liquid hydrogen storage tank. The test tank is approximately ellipsoidal, having a volume of 4.89 m(exp 3) and an average wall heat flux of 4.2 W/m(exp 2) due to external heat input. A mixer unit was installed near the bottom of the tank to generate an upward directed axial jet flow normal to the liquid-vapor interface. Mixing tests were initiated after achieving thermally stratified conditions in the tank either by the introduction of hydrogen gas into the tank or by self-pressurization due to ambient heat leak through the tank wall. The subcooled liquid jet directed towards the liquid-vapor interface by the mixer induced vapor condensation and caused a reduction in tank pressure. Tests were conducted at two jet submergence depths for jet Reynolds numbers from 80,000 to 495,000 and Richardson numbers from 0.014 to 0.52. Results show that the rate of tank pressure change is controlled by the competing effects of subcooled jet flow and the free convection boundary layer flow due to external tank wall heating. It is shown that existing correlations for mixing time and vapor condensation rate based on small scale tanks may not be applicable to large scale liquid hydrogen systems.

  8. Survival of Lactobacillus acidophilus and Bifidobacterium bifidum in ice cream for use as a probiotic food.

    PubMed

    Hekmat, S; McMahon, D J

    1992-06-01

    Probiotic ice cream was made by fermenting a standard ice cream mix with Lactobacillus acidophilus and Bifidobacterium bifidum cultures and then freezing the mix in a batch freezer. Survival of the L. acidophilus and B. bifidum, as well as beta-galactosidase activity, was monitored during 17 wk of frozen storage at -29 degrees C. After freezing of the fermented mix, bacterial counts were 1.5 x 10(8) cfu/ml for L. acidophilus and 2.5 x 10(8) cfu/ml for B. bifidum. Seventeen weeks after freezing, these counts had decreased to 4 x 10(6) and 1 x 10(7) cfu/ml, respectively. During the same period, beta-galactosidase activity decreased from 1800 to 1300 units/ml. Probiotic ice cream was prepared at pH 5.0, 5.5, and 6.0 to determine consumer preferences and was compared with standard Utah State University "Aggie" ice cream. All samples were strawberry-flavored and were evaluated by 88 judges. The preferred pH of probiotic ice cream, based on overall acceptance, was pH 5.5. We demonstrated that probiotic ice cream is a suitable vehicle for delivering beneficial microorganisms such as L. acidophilus and B. bifidum to consumers. The bacteria can be grown to high numbers in ice cream mix and remain viable during frozen storage.

  9. Quantification of Changes in Oxygen Release from Red Blood Cells as a Function of Age Based on Magnetic Susceptibility Measurements

    PubMed Central

    Jin, Xiaoxia; Yazer, Mark H.; Chalmers, Jeffrey J.; Zborowski, Maciej

    2013-01-01

    This study extends the in vitro understanding of the RBC storage lesion by serially analyzing the RBC’s magneophoretic mobility, a property dependent on the content and oxygenation or oxidation state of hemoglobin (Hb) iron, during storage. Four prestorage leukoreduced, AS-5 preserved RBC units were stored between 1–6°C for 42 days. Weekly starting on storage day 7, each unit was sampled, the aliquot divided into 3 portions and subjected to different reactions: one portion was exposed to room air to produce oxyhemoglobin (oxyHb), another portion was mixed with sodium nitrite to produce methemoglobin (metHb), while the third portion was desaturated of oxygen (deoxyhemoglobin, deoxyHb) using nitrogen gas. These portions were placed into a cell tracking velocimetry (CTV) apparatus which measured both the settling velocity (us) of the RBCs as well as their magnetically induced velocity (um). The um/us ratio depends on the oxygenation or oxidation state and quantity of iron within the RBC. RBC density was measured by percoll centrifugation. There was a significant reduction in the um/us ratio for the deoxyHb RBC portion as storage time elapsed, with a smaller but still significant reduction in the um/us ratio for the metHb portion. The average RBC density decreased very slightly during storage, as determined by percoll centrifugation technique, although the average settling velocity (another measure of cell density) seemed to fluctuate during storage. The decrease in magnetophoretic mobility of the deoxyHb portion, presented as the ratio of um/us, is explicable either by Hb’s increased affinity for oxygen during storage, or a loss of iron from the cells. PMID:21647486

  10. Assessment and Use of Optical Oxygen Sensors as Tools to Assist in Optimal Product Component Selection for the Development of Packs of Ready-to-Eat Mixed Salads and for the Non-Destructive Monitoring of in-Pack Oxygen Levels Using Chilled Storage.

    PubMed

    Hempel, Andreas W; O'Sullivan, Maurice G; Papkovsky, Dmitri B; Kerry, Joseph P

    2013-05-22

    Optical oxygen sensors were used to ascertain the level of oxygen consumed by individual salad leaves for optimised packaging of ready-to-eat (RTE) Italian salad mixes during refrigerated storage. Seven commonly found leaves in Italian salad mixes were individually assessed for oxygen utilisation in packs. Each leaf showed varying levels of respiration throughout storage. Using the information obtained, an experimental salad mix was formulated (termed Mix 3) which consisted of the four slowest respiring salad leaves-Escarole, Frisee, Red Batavia, Lollo Rosso. Mix 3 was then compared against two commercially available Italian salads; Mix 1 (Escarole, Frisee, Radicchio, Lollo Rosso) and Mix 2 (Cos, Frisee, Radicchio, Lollo Rosso). Optical sensors were used to non-destructively monitor oxygen usage in all mixes throughout storage. In addition to oxygen consumption, all three salad mixes were quality assessed in terms of microbial load and sensorial acceptability. In conclusion, Mix 3 was found to consume the least amount of oxygen over time, had the lowest microbial load and was most sensorially preferred ( p < 0.05) in terms of overall appearance and acceptability. This study clearly shows the potential that oxygen sensors possess in terms of assisting in the optimised development of commercial RTE salad products.

  11. 78 FR 48468 - Hewlett Packard Company, Hewlett Packard Enterprise Business Unit, EG HP Storage, Enterprise...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ..., Hewlett Packard Enterprise Business Unit, EG HP Storage, Enterprise Storage, Servers and Networking Storage, APP Management, Research and Development Group, Andover, Massachusetts; Notice of Investigation... Enterprise Business Unit, EG HP Storage, Enterprise Storage, Servers and Networking Storage Division, APP...

  12. Changes in ocean circulation and carbon storage are decoupled from air-sea CO2 fluxes

    NASA Astrophysics Data System (ADS)

    Marinov, I.; Gnanadesikan, A.

    2011-02-01

    The spatial distribution of the air-sea flux of carbon dioxide is a poor indicator of the underlying ocean circulation and of ocean carbon storage. The weak dependence on circulation arises because mixing-driven changes in solubility-driven and biologically-driven air-sea fluxes largely cancel out. This cancellation occurs because mixing driven increases in the poleward residual mean circulation result in more transport of both remineralized nutrients and heat from low to high latitudes. By contrast, increasing vertical mixing decreases the storage associated with both the biological and solubility pumps, as it decreases remineralized carbon storage in the deep ocean and warms the ocean as a whole.

  13. Changes in ocean circulation and carbon storage are decoupled from air-sea CO2 fluxes

    NASA Astrophysics Data System (ADS)

    Marinov, I.; Gnanadesikan, A.

    2010-11-01

    The spatial distribution of the air-sea flux of carbon dioxide is a poor indicator of the underlying ocean circulation and of ocean carbon storage. The weak dependence on circulation arises because mixing-driven changes in solubility-driven and biologically-driven air-sea fluxes largely cancel out. This cancellation occurs because mixing driven increases in the poleward residual mean circulation results in more transport of both remineralized nutrients and heat from low to high latitudes. By contrast, increasing vertical mixing decreases the storage associated with both the biological and solubility pumps, as it decreases remineralized carbon storage in the deep ocean and warms the ocean as a whole.

  14. Experimental and thermodynamic study of Co-Fe and Mn-Fe based mixed metal oxides for thermochemical energy storage application

    NASA Astrophysics Data System (ADS)

    André, Laurie; Abanades, Stéphane; Cassayre, Laurent

    2017-06-01

    Metal oxides are potential materials for thermochemical heat storage, and among them, cobalt oxide and manganese oxide are attracting attention. Furthermore, studies on mixed oxides are ongoing, as the synthesis of mixed oxides could be a way to answer the drawbacks of pure metal oxides, such as slow reaction kinetics, loss-in-capacity over cycles or sintering, selected for thermochemical heat storage application. The addition of iron oxide is under investigation and the obtained results are presented. This work proposes a comparison of thermodynamic modelling with experimental data in order to identify the impact of iron oxide addition to cobalt oxide and manganese oxide. Fe addition decreased the redox activity and energy storage capacity of Co3O4, whereas the cycling stability of Mn2O3 was significantly improved with added Fe amounts above 20 mol% while the energy storage capacity was unchanged. The thermodynamic modelling method to predict the behavior of the Mn-Fe-O and Co-Fe-O systems was validated, and the possibility to identify other mixed oxides becomes conceivable, by enabling the selection of transition metals additives for metal oxides destined for thermochemical energy storage applications.

  15. The potential of kiwifruit puree as a clean label ingredient to stabilize high pressure pasteurized cloudy apple juice during storage.

    PubMed

    Yi, Junjie; Kebede, Biniam; Kristiani, Kristiani; Buvé, Carolien; Van Loey, Ann; Grauwet, Tara; Hendrickx, Marc

    2018-07-30

    In the fruit juice industry, high pressure (HP) processing has become a commercial success. However, enzymatic browning, cloud loss, and flavor changes during storage remain challenges. The aim of this study is to combine kiwifruit puree and HP pasteurization (600 MPa/3 min) to stabilize cloudy apple juice during storage at 4 °C. A wide range of targeted and untargeted quality characteristics was evaluated using a multivariate approach. Due to high ascorbic acid content and high viscosity, kiwifruit puree allowed to prevent enzymatic browning and phase separation of an apple-kiwifruit mixed juice. Besides, no clear changes in organic acids, viscosity, and particle size distribution were detected in mixed juice during storage. Sucrose of apple and mixed juices decreased with glucose and fructose increasing during storage. The volatile changes of both juices behaved similar, mainly esters being degraded. Sensory evaluation demonstrated consumer preferred the aroma of mixed juice compared to apple juice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Comparative study of modified bitumen binder properties collected from mixing plant and quarry.

    NASA Astrophysics Data System (ADS)

    Mustafa Kamal, M.; Abu Bakar, R.; Hadithon, K. A.

    2017-11-01

    Quality control and assurance are essential in pavement construction. In general, the properties of bitumen change as it ages in bulk storage, transport, and storage on site. The minimization of bituminous hardening during storing, transportation and mixing depends on careful control of binder temperature. Hence therefore, bitumen should always be stored and handled at the lowest temperature possible, consistent with efficient use. The objective of the work is to monitor the quality of bitumen samples collected from mixing plant and quarry. Results showed that, samples modified bitumen which collected from quarry showed some adverse effects on rheological properties and physical properties after subjecting to high temperature storage within a period of time. The dynamic stiffness, elastic properties and other common binder properties were deteriorated too. The chemical changes that occurred during storage were analysed using Fourier transform infra-red spectroscopy (FTIR). Thus studies developed an understanding of bitumen ageing in storage.

  17. Diagnosis and treatment of male patients with lower urinary tract symptoms in Spain - The MERCURY Study. Do urologists follow the recommendations of the European guidelines?

    PubMed

    Errando-Smet, C; Müller-Arteaga, C; Hernández, M; Roset, M

    2018-02-07

    To explore the management of lower urinary tract symptoms (LUTS) in men in Spain and assess the compliance with recommendations established in the European Association of Urology (EAU) guidelines. MERCURY was an epidemiological and cross-sectional study which involved 227 Urology Units across Spain assessing adult male patients with mixed LUTS and persisting storage symptoms. Sociodemographic, clinical and resource use data for the 6 months prior to study inclusion were collected. Additionally, through a theoretical clinical case, clinicians described their attitude toward the diagnostic and therapeutic management of males with mixed LUTS and persisting storage symptoms during the first and second visits. Answer options given to clinicians about LUTS management were aligned with those recommended by EAU guidelines. 610 patients included in the study were evaluated. 87.7% of them consumed some health resource mainly due to: urologist visits (79.7%), PSA determination (76.6%) and treatment with alpha-blockers (37.5%) and alpha-blockers plus antimuscarinics (37.2%). According to the theoretical clinical case, urologists preference toward diagnostic tools and pharmacological treatment in first visit were mainly PSA determination (97.7%), digital rectal examination (91.4%) and treatment with alphablockers as monotherapy (56.6%), whereas in the second visit uroflowmetry (48.9%), voiding diary (40.3%) and treatment with alpha-blockers plus antimuscarinics (70.6%) were mainly preferred. Urologists attitude toward management of male patients with mixed LUTS and persisting storage symptoms is aligned with that recommended in the EAU guidelines. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Biogasification products of water hyacinth wastewater reclamation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chynoweth, D.P.; Biljetina, R.; Srivastava, V.J.

    1984-01-01

    This paper describes the results of research in progress to evaluate the use of water hyacinth for wastewater treatment and subsequent conversion of hyacinth and sludge to methane by anaerobic digestion. Laboratory studies have been directed toward evaluating advanced biogasification concepts and establishing a data base for the design and operation of an experimental test unit (ETU) located at the water hyacinth wastewater treatment facility at Walt Disney World (WDW) located in Kissimmee, Florida. Laboratory-scale kinetic experiments have been conducted using continuously-stirred tank reactors (CSTR) and a novel non-mixed upflow solids reactor (USR) receiving a hyacinth/sludge blend at retention timesmore » of 15 down to 2.1 days. The data suggest that best performance is achieved in the USR which has longer solids and organism retention. A larger-scale ETU (160 cu ft) was designed and installed at WDW in 1983 and started up in 1984. The purpose of this unit is to validate laboratory experiments and to evaluate larger-scale equipment used for chopping, slurry preparation, mixing, and effluent dewatering. The ETU includes a front end designed for multiple feed processing and storage, a fully instrumented USR digester, and tanks for effluent and gas storage. The ETU is currently being operated on a 2:1 blend (dry wt basis) of water hyacinth and primary sludge. Performance is good without major operational problems. Results of laboratory studies and start-up and operation of the ETU will be presented. 7 references, 4 figures, 1 table.« less

  19. Effects of thinning intensities on soil infiltration and water storage capacity in a Chinese pine-oak mixed forest.

    PubMed

    Chen, Lili; Yuan, Zhiyou; Shao, Hongbo; Wang, Dexiang; Mu, Xingmin

    2014-01-01

    Thinning is a crucial practice in the forest ecosystem management. The soil infiltration rate and water storage capacity of pine-oak mixed forest under three different thinning intensity treatments (15%, 30%, and 60%) were studied in Qinling Mountains of China. The thinning operations had a significant influence on soil infiltration rate and water storage capacity. The soil infiltration rate and water storage capacity in different thinning treatments followed the order of control (nonthinning): <60%, <15%, and <30%. It demonstrated that thinning operation with 30% intensity can substantially improve soil infiltration rate and water storage capacity of pine-oak mixed forest in Qinling Mountains. The soil initial infiltration rate, stable infiltration rate, and average infiltration rate in thinning 30% treatment were significantly increased by 21.1%, 104.6%, and 60.9%, compared with the control. The soil maximal water storage capacity and noncapillary water storage capacity in thinning 30% treatment were significantly improved by 20.1% and 34.3% in contrast to the control. The soil infiltration rate and water storage capacity were significantly higher in the surface layer (0~20 cm) than in the deep layers (20~40 cm and 40~60 cm). We found that the soil property was closely related to soil infiltration rate and water storage capacity.

  20. SCALE-MODEL STUDIES OF MIXING IN DRINKING WATER STORAGE TANKS

    EPA Science Inventory

    Storage tanks and reservoirs are commonly used in drinking water distribution systems to equalize pumping requirements and operating pressures, and to provide emergency water for fire-fighting and pumping outages. Poor mixing in these structures can create pockets of older water...

  1. Blood Preservation Study.

    DTIC Science & Technology

    1983-10-01

    red cells during storage. We discovered that periodic mixing during storage increases the levels of 2,3- diphosphoglycerate , and probably as a...214. 21. Wood, L.A. and Beutler, E. 1973. The effect of periodic mixing on the preservation of 2,3- diphosphoglycerate (2,3- dpg) levels in stored blood...determine the rate of depletion of 2,3- diphosphoglycerate from stored red cells, to determine the effect of different storage conditions on the rate

  2. Geohydrology of Storage Unit III and a combined flow model of the Santa Barbara and foothill ground-water basins, Santa Barbara County, California

    USGS Publications Warehouse

    Freckleton, John R.; Martin, Peter; Nishikawa, Tracy

    1998-01-01

    The city of Santa Barbara pumps most of its ground water from the Santa Barbara and Foothill ground-water basins. The Santa Barbara basin is subdivided into two storage units: Storage Unit I and Storage Unit III. The Foothill basin and Storage Unit I of the Santa Barbara basin have been studied extensively and ground-water flow models have been developed for them. In this report, the geohydrology of the Santa Barbara ground- water basin is described with a special emphasis on Storage Unit III in the southwestern part of the basin. The purposes of this study were to summarize and evaluate the geohydrology of Storage Unit III and to develop an areawide model of the Santa Barbara and Foothill basins that includes the previously unmodeled Storage Unit III. Storage Unit III is in the southwestern part of the city of Santa Barbara. It is approximately 3.5 miles long and varies in width from about 2,000 feet in the southeast to 4,000 feet in the north-west. Storage Unit III is composed of the Santa Barbara Formation and overlying alluvium. The Santa Barbara Formation (the principal aquifer) consists of Pleistocene and Pliocene(?) unconsolidated marine sand, silt, and clay, and it has a maximum saturated thickness of about 160 feet. The alluvium that overlies the Santa Barbara Formation has a maximum saturated thickness of about 140 feet. The storage unit is bounded areally by faults and low-permeability deposits and is underlain by rocks of Tertiary age. The main sources of recharge to Storage Unit III are seepage from Arroyo Burro and infiltration of precipitation. Most of the recharge occurs in the northwest part of the storage unit, and ground water flows toward the southeast along the unit's long axis. Lesser amounts of recharge may occur as subsurface flow from the Hope Ranch subbasin and as upwelling from the underlying Tertiary rocks. Discharge from Storage Unit III occurs as pumpage, flow to underground drains, underflow through alluvium in the vicinity of Arroyo Burro across the Lavigia Fault, evapotranspiration, and underflow to the Pacific Ocean. The faults that bound Storage Unit III generally are considered to be effective barriers to the flow of ground water. Interbasin ground-water flow occurs where deposits of younger alluvium along stream channels cross faults. Ground-water quality in Storage Unit III deposits varies with location and depth. Upward leakage of poor-quality water from the underlying Tertiary rocks occurs in the storage unit, and such leakage can be influenced by poor well construction or by heavy localized pumping. The highest dissolved-solids concentration (4,710 milligrams per liter) in ground water resulting from this upward leakage is found in the coastal part of the storage unit. The ground-water system was modeled as two horizontal layers. In the Foothill basin and Storage Unit I the layers are separated by a confining bed. The upper layer represents the upper producing zone and the shallow zone near the coast. The lower layer represents the lower producing zone. In general, the faults in the study area were assumed to be no-flow boundaries, except for the offshore fault that forms the southeast boundary; the southeast boundary was simulated as a general-head boundary. The Storage Unit III model was combined with the preexisting Storage Unit I and Foothill basin models, using horizontal flow barriers, to form an areawide model. The areawide model was calibrated by simulating steady-state predevelopment conditions and transient conditions for 1978-92. The nonpumping steady- state simulation was used to verify that the calibrated model yielded physically reasonable results for predevelopment conditions. The calibrated areawide model calculates water levels in Storage Unit III that are within 10 feet of measured water levels at all sites of comparison. In addition, the model adequately simulates water levels in the Storage Unit I and Foothill basin areas. A total of 33,430 acre-feet of water was pum

  3. Resource Conservation and Recovery Act (RCRA) Part B permit application for tank storage units at the Oak Ridge Y-12 Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-05-01

    In compliance with the Resource Conservation and Recovery Act (RCRA), this report discusses information relating to permit applications for three tank storage units at Y-12. The storage units are: Building 9811-1 RCRA Tank Storage Unit (OD-7); Waste Oil/Solvent Storage Unit (OD-9); and Liquid Organic Solvent Storage Unit (OD-10). Numerous sections discuss the following: Facility description; waste characteristics; process information; groundwater monitoring; procedures to prevent hazards; contingency plan; personnel training; closure plan, post closure plan, and financial requirements; record keeping; other federal laws; organic air emissions; solid waste management units; and certification. Sixteen appendices contain such items as maps, waste analysesmore » and forms, inspection logs, equipment identification, etc.« less

  4. 44. GLAZE STORAGE AND MIXING AREA, GROUND FLOOR, EAST WING. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. GLAZE STORAGE AND MIXING AREA, GROUND FLOOR, EAST WING. TILES ARE DIPPED IN GLAZE AT THE COUNTER AGAINST THE FAR WALL. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA

  5. Dynamics of transit times and StorAge Selection functions in four forested catchments from stable isotope data

    NASA Astrophysics Data System (ADS)

    Rodriguez, Nicolas B.; McGuire, Kevin J.; Klaus, Julian

    2017-04-01

    Transit time distributions, residence time distributions and StorAge Selection functions are fundamental integrated descriptors of water storage, mixing, and release in catchments. In this contribution, we determined these time-variant functions in four neighboring forested catchments in H.J. Andrews Experimental Forest, Oregon, USA by employing a two year time series of 18O in precipitation and discharge. Previous studies in these catchments assumed stationary, exponentially distributed transit times, and complete mixing/random sampling to explore the influence of various catchment properties on the mean transit time. Here we relaxed such assumptions to relate transit time dynamics and the variability of StoreAge Selection functions to catchment characteristics, catchment storage, and meteorological forcing seasonality. Conceptual models of the catchments, consisting of two reservoirs combined in series-parallel, were calibrated to discharge and stable isotope tracer data. We assumed randomly sampled/fully mixed conditions for each reservoir, which resulted in an incompletely mixed system overall. Based on the results we solved the Master Equation, which describes the dynamics of water ages in storage and in catchment outflows Consistent between all catchments, we found that transit times were generally shorter during wet periods, indicating the contribution of shallow storage (soil, saprolite) to discharge. During extended dry periods, transit times increased significantly indicating the contribution of deeper storage (bedrock) to discharge. Our work indicated that the strong seasonality of precipitation impacted transit times by leading to a dynamic selection of stored water ages, whereas catchment size was not a control on transit times. In general this work showed the usefulness of using time-variant transit times with conceptual models and confirmed the existence of the catchment age mixing behaviors emerging from other similar studies.

  6. Kinetics of changes in shelf life parameters during storage of pearl millet based kheer mix and development of a shelf life prediction model.

    PubMed

    Bunkar, Durga Shankar; Jha, Alok; Mahajan, Ankur; Unnikrishnan, V S

    2014-12-01

    Pearl millet, dairy whitener and sugar powder were blended for preparing pearl millet kheer mix. Pearl millet based kheer mix samples were stored at 8, 25, 37 and 45 °C under nitrogen flushing environment. Changes in HMF and TBA formation in the dry mix and sensory changes in reconstituted kheer were studied upto 180 days. In fresh dry mix, the average value of HMF recorded was 4.87 μmol/g which increased to 11.23, 13.67, 18.13, and 21.43 μmol/g at 8, 25, 37 and 45 °C, respectively after 180 days of storage. From an initial value of 0.067, the TBA value increased to 0.219, 0.311, 0.432 and 0.613 at 532 nm at 8, 25, 37 and 45 °C, respectively after 180 days of storage. Data generated from the chemical kinetics of HMF and TBA development that progressed during storage of pearl millet kheer mix were modeled using Arrhenius equations to predict the shelf life of the product. Changes in HMF and TBA followed first order reaction kinetics. It was found that the potential shelf life of the pearl millet based kheer mix was 396 days at 8 and 288 days at 25 °C, respectively.

  7. Fraction-storage unit for drug-identification system

    NASA Technical Reports Server (NTRS)

    Campen, C. F.; Stuart, J. L.

    1976-01-01

    Device, connecting outputs of all gas chromatographs to single, relatively inexpensive IR spectrometer, reduces costs of system. Storage unit provides buffer storage of samples until infrared spectrometer is ready to accept them. Storage unit can be used to separate overlapping peaks.

  8. National Assessment of Geologic Carbon Dioxide Storage Resources -- Trends and Interpretations

    NASA Astrophysics Data System (ADS)

    Buursink, M. L.; Blondes, M. S.; Brennan, S.; Drake, R., II; Merrill, M. D.; Roberts-Ashby, T. L.; Slucher, E. R.; Warwick, P.

    2013-12-01

    In 2012, the U.S. Geological Survey (USGS) completed an assessment of the technically accessible storage resource (TASR) for carbon dioxide (CO2) in geologic formations underlying the onshore and State waters area of the United States. The formations assessed are at least 3,000 feet (914 meters) below the ground surface. The TASR is an estimate of the CO2 storage resource that may be available for CO2 injection and storage that is based on present-day geologic and hydrologic knowledge of the subsurface and current engineering practices. Individual storage assessment units (SAUs) for 36 basins or study areas were defined on the basis of geologic and hydrologic characteristics outlined in the USGS assessment methodology. The mean national TASR is approximately 3,000 metric gigatons. To augment the release of the assessment, this study reviews input estimates and output results as a part of the resource calculation. Included in this study are a collection of both cross-plots and maps to demonstrate our trends and interpretations. Alongside the assessment, the input estimates were examined for consistency between SAUs and cross-plotted to verify expected trends, such as decreasing storage formation porosity with increasing SAU depth, for instance, and to show a positive correlation between storage formation porosity and permeability estimates. Following the assessment, the output results were examined for correlation with selected input estimates. For example, there exists a positive correlation between CO2 density and the TASR, and between storage formation porosity and the TASR, as expected. These correlations, in part, serve to verify our estimates for the geologic variables. The USGS assessment concluded that the Coastal Plains Region of the eastern and southeastern United States contains the largest storage resource. Within the Coastal Plains Region, the storage resources from the U.S. Gulf Coast study area represent 59 percent of the national CO2 storage capacity. As part of this follow up study, additional maps were generated to show the geographic distribution of the input estimates and the output results across the U.S. For example, the distribution of the SAUs with fresh, saline or mixed formation water quality is shown. Also mapped is the variation in CO2 density as related to basin location and to related properties such as subsurface temperature and pressure. Furthermore, variation in the estimated SAU depth and resulting TASR are shown across the assessment study areas, and these depend on the geologic basin size and filling history. Ultimately, multiple map displays are possible with the complete data set of input estimates and range of reported results. The findings from this study show the effectiveness of the USGS methodology and the robustness of the assessment.

  9. Demonstration of Isothermal Compressed Air Energy Storage to Support Renewable Energy Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bollinger, Benjamin

    This project develops and demonstrates a megawatt (MW)-scale Energy Storage System that employs compressed air as the storage medium. An isothermal compressed air energy storage (ICAES TM) system rated for 1 MW or more will be demonstrated in a full-scale prototype unit. Breakthrough cost-effectiveness will be achieved through the use of proprietary methods for isothermal gas cycling and staged gas expansion implemented using industrially mature, readily-available components.The ICAES approach uses an electrically driven mechanical system to raise air to high pressure for storage in low-cost pressure vessels, pipeline, or lined-rock cavern (LRC). This air is later expanded through the samemore » mechanical system to drive the electric motor as a generator. The approach incorporates two key efficiency-enhancing innovations: (1) isothermal (constant temperature) gas cycling, which is achieved by mixing liquid with air (via spray or foam) to exchange heat with air undergoing compression or expansion; and (2) a novel, staged gas-expansion scheme that allows the drivetrain to operate at constant power while still allowing the stored gas to work over its entire pressure range. The ICAES system will be scalable, non-toxic, and cost-effective, making it suitable for firming renewables and for other grid applications.« less

  10. Favorable Decision Upholding Radioactive/Hazardous Mixed Waste Storage Civil Enforcement Policy

    EPA Pesticide Factsheets

    This page contains a copy of the U.S. Court of Appeals (District of Columbia Circuit) decision in Edison Electric Institute, et al. v. EPA, No. 91-1586, which upheld the EPA's August 29, 1991, radioactive/hazardous 'mixed waste' storage civil enforcement policy

  11. Transient analysis of a thermal storage unit involving a phase change material

    NASA Technical Reports Server (NTRS)

    Griggs, E. I.; Pitts, D. R.; Humphries, W. R.

    1974-01-01

    The transient response of a single cell of a typical phase change material type thermal capacitor has been modeled using numerical conductive heat transfer techniques. The cell consists of a base plate, an insulated top, and two vertical walls (fins) forming a two-dimensional cavity filled with a phase change material. Both explicit and implicit numerical formulations are outlined. A mixed explicit-implicit scheme which treats the fin implicity while treating the phase change material explicitly is discussed. A band algorithmic scheme is used to reduce computer storage requirements for the implicit approach while retaining a relatively fine grid. All formulations are presented in dimensionless form thereby enabling application to geometrically similar problems. Typical parametric results are graphically presented for the case of melting with constant heat input to the base of the cell.

  12. Solar heating and cooling diode module

    DOEpatents

    Maloney, Timothy J.

    1986-01-01

    A high efficiency solar heating system comprising a plurality of hollow modular units each for receiving a thermal storage mass, the units being arranged in stacked relation in the exterior frame of a building, each of the units including a port for filling the unit with the mass, a collector region and a storage region, each region having inner and outer walls, the outer wall of the collector region being oriented for exposure to sunlight for heating the thermal storage mass; the storage region having an opening therein and the collector region having a corresponding opening, the openings being joined for communicating the thermal storage mass between the storage and collector regions by thermosiphoning; the collector region being disposed substantially below and in parallel relation to the storage region in the modular unit; and the inner wall of the collector region of each successive modular unit in the stacked relation extending over the outer wall of the storage region of the next lower modular unit in the stacked relation for reducing heat loss from the system. Various modifications and alternatives are disclosed for both heating and cooling applications.

  13. Effects of Thinning Intensities on Soil Infiltration and Water Storage Capacity in a Chinese Pine-Oak Mixed Forest

    PubMed Central

    Chen, Lili; Yuan, Zhiyou; Shao, Hongbo; Wang, Dexiang; Mu, Xingmin

    2014-01-01

    Thinning is a crucial practice in the forest ecosystem management. The soil infiltration rate and water storage capacity of pine-oak mixed forest under three different thinning intensity treatments (15%, 30%, and 60%) were studied in Qinling Mountains of China. The thinning operations had a significant influence on soil infiltration rate and water storage capacity. The soil infiltration rate and water storage capacity in different thinning treatments followed the order of control (nonthinning): <60%, <15%, and <30%. It demonstrated that thinning operation with 30% intensity can substantially improve soil infiltration rate and water storage capacity of pine-oak mixed forest in Qinling Mountains. The soil initial infiltration rate, stable infiltration rate, and average infiltration rate in thinning 30% treatment were significantly increased by 21.1%, 104.6%, and 60.9%, compared with the control. The soil maximal water storage capacity and noncapillary water storage capacity in thinning 30% treatment were significantly improved by 20.1% and 34.3% in contrast to the control. The soil infiltration rate and water storage capacity were significantly higher in the surface layer (0~20 cm) than in the deep layers (20~40 cm and 40~60 cm). We found that the soil property was closely related to soil infiltration rate and water storage capacity. PMID:24883372

  14. 40 CFR 266.220 - What does a storage and treatment conditional exemption do?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Conditional Exemption for Low-Level Mixed Waste Storage... exemption exempts your low-level mixed waste from the regulatory definition of hazardous waste in 40 CFR 261...

  15. 21 CFR 1271.260 - Storage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Storage. 1271.260 Section 1271.260 Food and Drugs... TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.260 Storage. (a) Control of storage areas. You must control your storage areas and stock rooms to prevent: (1) Mix-ups, contamination, and cross...

  16. 21 CFR 1271.260 - Storage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Storage. 1271.260 Section 1271.260 Food and Drugs... TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.260 Storage. (a) Control of storage areas. You must control your storage areas and stock rooms to prevent: (1) Mix-ups, contamination, and cross...

  17. 21 CFR 1271.260 - Storage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Storage. 1271.260 Section 1271.260 Food and Drugs... TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.260 Storage. (a) Control of storage areas. You must control your storage areas and stock rooms to prevent: (1) Mix-ups, contamination, and cross...

  18. 21 CFR 1271.260 - Storage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Storage. 1271.260 Section 1271.260 Food and Drugs... TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.260 Storage. (a) Control of storage areas. You must control your storage areas and stock rooms to prevent: (1) Mix-ups, contamination, and cross...

  19. Mixed feed and its ingredients electron beam decontamination

    NASA Astrophysics Data System (ADS)

    Bezuglov, V. V.; Bryazgin, A. A.; Vlasov, A. Yu; Voronin, L. A.; Ites, Yu V.; Korobeynikov, M. V.; Leonov, S. V.; Leonova, M. A.; Tkachenko, V. O.; Shtarklev, E. A.; Yuskov, Yu G.

    2017-01-01

    Electron beam treatment is used for food processing for decades to prevent or minimize food losses and prolong storage time. This process is also named cold pasteurization. Mixed feed ingredients supplied in Russia regularly occur to be contaminated. To reduce contamination level the contaminated mixed feed ingredients samples were treated by electron beam with doses from 2 to 12 kGy. The contamination levels were decreased to the level that ensuring storage time up to 1 year.

  20. Benefits of tree mixes in carbon plantings

    NASA Astrophysics Data System (ADS)

    Hulvey, Kristin B.; Hobbs, Richard J.; Standish, Rachel J.; Lindenmayer, David B.; Lach, Lori; Perring, Michael P.

    2013-10-01

    Increasingly governments and the private sector are using planted forests to offset carbon emissions. Few studies, however, examine how tree diversity -- defined here as species richness and/or stand composition -- affects carbon storage in these plantings. Using aboveground tree biomass as a proxy for carbon storage, we used meta-analysis to compare carbon storage in tree mixtures with monoculture plantings. Tree mixes stored at least as much carbon as monocultures consisting of the mixture's most productive species and at times outperformed monoculture plantings. In mixed-species stands, individual species, and in particular nitrogen-fixing trees, increased stand biomass. Further motivations for incorporating tree richness into planted forests include the contribution of diversity to total forest carbon-pool development, carbon-pool stability and the provision of extra ecosystem services. Our findings suggest a two-pronged strategy for designing carbon plantings including: (1) increased tree species richness; and (2) the addition of species that contribute to carbon storage and other target functions.

  1. Water vapor diffusion membrane development

    NASA Technical Reports Server (NTRS)

    Tan, M. K.

    1977-01-01

    An application of the water vapor diffusion technique is examined whereby the permeated water vapor is vented to space vacuum to alleviate on-board waste storage and provide supplemental cooling. The work reported herein deals primarily with the vapor diffusion-heat rejection (VD-HR) as it applies to the Space Shuttle. A stack configuration was selected, designed and fabricated. An asymmetric cellulose acetate membrane, used in reverse osmosis application was selected and a special spacer was designed to enhance mixing and promote mass transfer. A skid-mount unit was assembled from components used in the bench unit although no attempt was made to render it flight-suitable. The operating conditions of the VD-HR were examined and defined and a 60-day continuous test was carried out. The membranes performed very well throughout the test; no membrane rupture and no unusual flux decay was observed. In addition, a tentative design for a flight-suitable VD-HR unit was made.

  2. Impact of Wind and Solar on the Value of Energy Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul; Jorgenson, Jennie; Hummon, Marissa

    2013-11-01

    This analysis evaluates how the value of energy storage changes when adding variable generation (VG) renewable energy resources to the grid. A series of VG energy penetration scenarios from 16% to 55% were generated for a utility system in the western United States. This operational value of storage (measured by its ability to reduce system production costs) was estimated in each VG scenario, considering provision of different services and with several sensitivities to fuel price and generation mix. Overall, the results found that the presence of VG increases the value of energy storage by lowering off-peak energy prices more thanmore » on-peak prices, leading to a greater opportunity to arbitrage this price difference. However, significant charging from renewables, and consequently a net reduction in carbon emissions, did not occur until VG penetration was in the range of 40%-50%. Increased penetration of VG also increases the potential value of storage when providing reserves, mainly by increasing the amount of reserves required by the system. Despite this increase in value, storage may face challenges in capturing the full benefits it provides. Due to suppression of on-/off-peak price differentials, reserve prices, and incomplete capture of certain system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit (reduction in production costs) provided to the system. Furthermore, it is unclear how storage will actually incentivize large-scale deployment of renewables needed to substantially increase VG penetration. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.« less

  3. Advantages from Mixed Storage of Ammunition

    DTIC Science & Technology

    1983-07-01

    A^dN^MM ADy^->6y 7<^ TECHNICAL REPORT ARBRL-TR-02506 ADVANTAGES FROM MIXED STORAGE OF AMMUNITION Ona R. Lyman July 1983 US ARMY ARMAMENT...that "weigh out." Benefits can be derived from mixing an ammunition that "weighs out" with ammunition that "cubes out." In principle, it is...accessible. Below is listed a step-by-step procedure for determining benefits to be derived. Step 1. Select a munition that "weighs out" and note if more

  4. High-temperature thermochemical energy storage based on redox reactions using Co-Fe and Mn-Fe mixed metal oxides

    NASA Astrophysics Data System (ADS)

    André, Laurie; Abanades, Stéphane; Cassayre, Laurent

    2017-09-01

    Metal oxides are potential materials for thermochemical heat storage via reversible endothermal/exothermal redox reactions, and among them, cobalt oxide and manganese oxide are attracting attention. The synthesis of mixed oxides is considered as a way to answer the drawbacks of pure metal oxides, such as slow reaction kinetics, loss-in-capacity over cycles or sintering issues, and the materials potential for thermochemical heat storage application needs to be assessed. This work proposes a study combining thermodynamic calculations and experimental measurements by simultaneous thermogravimetric analysis and calorimetry, in order to identify the impact of iron oxide addition to Co and Mn-based oxides. Fe addition decreased the redox activity and energy storage capacity of Co3O4/CoO, whereas the reaction rate, reversibility and cycling stability of Mn2O3/Mn3O4 was significantly enhanced with added Fe amounts above 15 mol%, and the energy storage capacity was slightly improved. The formation of a reactive cubic spinel explained the improved re-oxidation yield of Mn-based oxides that could be cycled between bixbyite and cubic spinel phases, whereas a low reactive tetragonal spinel phase showing poor re-oxidation was formed below 15 mol% Fe. Thermodynamic equilibrium calculations predict accurately the behavior of both systems. The possibility to identify other suitable mixed oxides becomes conceivable, by enabling the selection of transition metal additives for tuning the redox properties of mixed metal oxides destined for thermochemical energy storage applications.

  5. Initial substrate moisture content and storage temperature affects chemical properties of bagged substrates containing controlled release fertilizer at two different temperatures

    USDA-ARS?s Scientific Manuscript database

    Bagged potting mixes can be stored for weeks or months before being used by consumers. Some bagged potting mixes are amended with controlled release fertilizers (CRF). The objective of this research was to observe how initial substrate moisture content and storage temperature affect the chemical p...

  6. Amylose-potassium oleate inclusion complex in plain set-style yogurt.

    PubMed

    Singh, Mukti; Byars, Jeffrey A; Kenar, James A

    2014-05-01

    Health and wellness aspirations of U.S. consumers continue to drive the demand for lower fat from inherently beneficial foods such as yogurt. Removing fat from yogurt negatively affects the gel strength, texture, syneresis, and storage of yogurt. Amylose-potassium oleate inclusion complexes (AIC) were used to replace skim milk solids to improve the quality of nonfat yogurt. The effect of AIC on fermentation of yogurt mix and strength of yogurt gel was studied and compared to full-fat samples. Texture, storage modulus, and syneresis of yogurt were observed over 4 weeks of storage at 4 °C. Yogurt mixes having the skim milk solids partially replaced by AIC fermented at a similar rate as yogurt samples with no milk solids replaced and full-fat milk. Initial viscosity was higher for yogurt mixes with AIC. The presence of 3% AIC strengthened the yogurt gel as indicated by texture and rheology measurements. Yogurt samples with 3% AIC maintained the gel strength during storage and resulted in low syneresis after storage for 4 wk. © 2014 Institute of Food Technologists®

  7. Battery management system with distributed wireless sensors

    DOEpatents

    Farmer, Joseph C.; Bandhauer, Todd M.

    2016-02-23

    A system for monitoring parameters of an energy storage system having a multiplicity of individual energy storage cells. A radio frequency identification and sensor unit is connected to each of the individual energy storage cells. The radio frequency identification and sensor unit operates to sense the parameter of each individual energy storage cell and provides radio frequency transmission of the parameters of each individual energy storage cell. A management system monitors the radio frequency transmissions from the radio frequency identification and sensor units for monitoring the parameters of the energy storage system.

  8. Controls on Water Storage, Mixing and Release in a Nested Catchment Set-up with Clean and Mixed Physiographic Characteristics

    NASA Astrophysics Data System (ADS)

    Pfister, L.; McDonnell, J.; Hissler, C.; Martínez-Carreras, N.; Klaus, J.

    2015-12-01

    With catchment water storage being only rarely determined, storage dynamics remain largely unknown to date. However, storage bears considerable potential for catchment inter-comparison exercises, as well as it is likely to have an important role in regulating catchment functions. Catchment comparisons across a wide range of environments and scales will help to increase our understanding of relationships between storage dynamics and catchment processes. With respect to the potential of catchment storage for bringing new momentum to catchment classification and catchment processes understanding we currently investigate spatial and temporal variability of dynamic storage in a nested catchment set-up (16 catchments) of the Alzette River basin (Luxembourg, Europe), covering a wide range of geological settings, catchment areas, contrasted landuse, and hydro-meteorological and tracer series. We define catchment storage as the total amount of water stored in a control volume, delimited by the catchment's topographical boundaries and depth of saturated and unsaturated zones. Complementary storage assessments (via input-output dynamics of natural tracers, geographical sounding, groundwater level measurements, soil moisture measurements, hydrometry) are carried out for comparison purposes. In our nested catchment set-up we have (1) assessed dependencies between geology, catchment permeability and winter runoff coefficients, (2) calculated water balance derived catchment storage and mixing potential and quantified how dynamic storage differs between catchments and scales, and (3) examined how stream baseflow dD (as a proxy for baseflow transit time) and integrated flow measures (like the flow duration curve) relate to bedrock geology. Catchments with higher bedrock permeability exhibited larger storage capacities and eventually lower average winter runoff coefficients. Over a time-span of 11 years, all catchments re-produced the same winter runoff coefficients year after year, regardless of their bedrock geology, permeability and winter season storage filling ratios. Ultimately, catchment organisation in our area of interest (i.e. geology, permeability, flowpath length) appeared to have a strong control on winter runoff coefficients, catchment storage and subsequently baseflow dD.

  9. System for operating solid oxide fuel cell generator on diesel fuel

    NASA Technical Reports Server (NTRS)

    Singh, Prabhu (Inventor); George, Raymond A. (Inventor)

    1997-01-01

    A system is provided for operating a solid oxide fuel cell generator on diesel fuel. The system includes a hydrodesulfurizer which reduces the sulfur content of commercial and military grade diesel fuel to an acceptable level. Hydrogen which has been previously separated from the process stream is mixed with diesel fuel at low pressure. The diesel/hydrogen mixture is then pressurized and introduced into the hydrodesulfurizer. The hydrodesulfurizer comprises a metal oxide such as ZnO which reacts with hydrogen sulfide in the presence of a metal catalyst to form a metal sulfide and water. After desulfurization, the diesel fuel is reformed and delivered to a hydrogen separator which removes most of the hydrogen from the reformed fuel prior to introduction into a solid oxide fuel cell generator. The separated hydrogen is then selectively delivered to the diesel/hydrogen mixer or to a hydrogen storage unit. The hydrogen storage unit preferably comprises a metal hydride which stores hydrogen in solid form at low pressure. Hydrogen may be discharged from the metal hydride to the diesel/hydrogen mixture at low pressure upon demand, particularly during start-up and shut-down of the system.

  10. Nutritive value and fermentation characteristics of alfalfa-mixed grass forage wrapped with minimal stretch film layers and stored for different lengths of time.

    PubMed

    Coblentz, W K; Ogden, R K; Akins, M S; Chow, E A

    2017-07-01

    A key aspect of managing baled silages is to quickly achieve and then rigorously maintain anaerobic conditions within the silage mass. The concept of inserting an O 2 -limiting barrier (OB) into plastic commercial silage wraps has been evaluated previously, yielding mixed or inconclusive results. Our objective for this study was to maximize the challenge to a commercial polyethylene bale wrap, or the identical wrap containing an OB, by using minimal plastic (4 layers), and then extending storage periods as long as 357 d. Forty-eight 1.2 × 1.2-m large-round bales of alfalfa (Medicago sativa L.) and mixed grass forage (66.3 ± 8.66% alfalfa; DM basis) were made at 2 moisture concentrations [47.5 (ideal) or 36.1% (dry)], wrapped with 4 layers of plastic containing an OB or no OB, and then stored for 99, 243, or 357 d. After storage, yeast counts within the 0.15-m deep surface layer were not affected by treatment (mean = 5.85 log 10 cfu/g); mold counts could not be analyzed statistically because 26 bales were nondetectable at a 3.00 log 10 cfu/g detection limit, but means among detectable counts were numerically similar for OB (4.74 log 10 cfu/g) and no OB (4.77 log 10 cfu/g). Fermentation characteristics were most affected by initial bale moisture, resulting in a more acidic final pH for ideal compared with dry bales (5.52 vs. 6.00). This was facilitated by greater concentrations of total fermentation acids (3.80 vs. 1.45% of dry matter), lactic acid (2.24 vs. 0.71% of dry matter), and acetic acid (1.07 vs. 0.64% of dry matter) within ideal compared with dry silages. Plastic wrap type had no effect on final concentrations of any fermentation product. During fermentation and storage, we noted greater change in concentrations of fiber components and whole-plant ash within the 0.15-m deep surface layer than in the bale core, and these changes always differed statistically from 0 (no change) based on pre-ensiled baseline concentrations. Overall, concentrations of water-soluble carbohydrates were reduced (mean = 2.3 percentage units) during fermentation and storage, which resulted (indirectly) in increased concentrations of fiber components and crude protein, as well as an overall energy cost of 2.2 percentage units of total digestible nutrient. It remains unclear under what conditions an OB plastic wrap will consistently benefit the fermentation and preservation of baled silages. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Resource Conservation and Recovery Act (RCRA) Part B Permit Application for Production Associated Units at the Oak Ridge Y-12 Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This is the RCRA required permit application for Radioactive and Hazardous Waste Management at the Oak Ridge Y-12 Plant for the following units: Building 9206 Container Storage Unit; Building 9212 Container Storage Unit; Building 9720-12 Container Storage Unit; Cyanide Treatment Unit. All four of these units are associated with the recovery of enriched uranium and other metals from wastes generated during the processing of nuclear materials.

  12. Risk assessment of CST-7 proposed waste treatment and storage facilities Volume I: Limited-scope probabilistic risk assessment (PRA) of proposed CST-7 waste treatment & storage facilities. Volume II: Preliminary hazards analysis of proposed CST-7 waste storage & treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasser, K.

    1994-06-01

    In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less

  13. Distributed trace using central performance counter memory

    DOEpatents

    Satterfield, David L; Sexton, James C

    2013-10-22

    A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.

  14. Distributed trace using central performance counter memory

    DOEpatents

    Satterfield, David L.; Sexton, James C.

    2013-01-22

    A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.

  15. Studies of Phase Change Materials and a Latent Heat Storage Unit Used for a Natural Circulation Cooling/Latent Heat Storage System

    NASA Astrophysics Data System (ADS)

    Sakitani, Katsumi; Honda, Hiroshi

    Experiments were performed to investigate feasibility of using organic materials as a PCM for a latent heat storage unit of a natural circulation cooling/latent heat storage system. This system was designed to cool a shelter accommodating telecommunication equipment located in subtropical deserts or similar regions without using a power source. Taking into account practical considerations and the results of various experiments regarding the thermodynamic properties, thermal degradation, and corrosiveness to metals, lauric acid and iron was selected for the PCM and the latent heat storage unit material, respectively. Cyclic heating and cooling of the latent heat storage unit undergoing solid-liquid phase change was repeated for more than 430 days. The results showed that the heating-cooling curve was almost unchanged between the early stage and the 1,870th cycle. It was concluded that the latent heat storage unit could be used safely for more than ten years as a component of the cooling system.

  16. RCRA Refresher Self-Study, Course 28582

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, Lewis Edward

    Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.

  17. RCRA Personnel Training, Course 7488

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, Lewis Edward

    Federal and state regulations require hazardous and mixed waste facility workers at treatment and storage facilities (TSFs) and <90-day accumulation areas to be trained in hazardous and mixed waste management. This course will refamiliarize and update <90-day accumulation area workers, TSF workers, and supervisors of TSF workers regarding waste identification, pollution prevention, storage area requirements, emergency response procedures, and record-keeping requirements.

  18. Storage peak gas-turbine power unit

    NASA Technical Reports Server (NTRS)

    Tsinkotski, B.

    1980-01-01

    A storage gas-turbine power plant using a two-cylinder compressor with intermediate cooling is studied. On the basis of measured characteristics of a .25 Mw compressor computer calculations of the parameters of the loading process of a constant capacity storage unit (05.3 million cu m) were carried out. The required compressor power as a function of time with and without final cooling was computed. Parameters of maximum loading and discharging of the storage unit were calculated, and it was found that for the complete loading of a fully unloaded storage unit, a capacity of 1 to 1.5 million cubic meters is required, depending on the final cooling.

  19. Corrective action investigation plan for Corrective Action Unit 340, Pesticide Release Sites, Nevada Test Site, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This Correction Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense. As required by the FFACO (1996), this document provides or references all of the specific information for planning investigation activities associated with three Corrective Action Sites (CASs) located at the Nevada Test Site (NTS). These CASs are collectively known as Corrective Action Unit (CAU) 340, Pesticide Release Sites. According to themore » FFACO, CASs are sites that may require corrective action(s) and may include solid waste management units or individual disposal or release sites. These sites are CAS 23-21-01, Area 23 Quonset Hut 800 (Q800) Pesticide Release Ditch; CAS 23-18-03, Area 23 Skid Huts Pesticide Storage; and CAS 15-18-02, Area 15 Quonset Hut 15-11 Pesticide Storage (Q15-11). The purpose of this CAIP for CAU 340 is to direct and guide the investigation for the evaluation of the nature and extent of pesticides, herbicides, and other contaminants of potential concern (COPCs) that were stored, mixed, and/or disposed of at each of the CASs.« less

  20. 30 CFR 57.6960 - Mixing of explosive material.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...

  1. 30 CFR 57.6960 - Mixing of explosive material.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...

  2. 30 CFR 57.6960 - Mixing of explosive material.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...

  3. 30 CFR 57.6960 - Mixing of explosive material.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...

  4. 30 CFR 57.6960 - Mixing of explosive material.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...

  5. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing†

    PubMed Central

    Jensen, Erik C.; Stockton, Amanda M.; Chiesl, Thomas N.; Kim, Jungkyu; Bera, Abhisek; Mathies, Richard A.

    2013-01-01

    A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (µL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>26 unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses. PMID:23172232

  6. Presentation of the 2007 Richard S. Hodes, M.D. Honor Lecture Award

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNamara, L.

    Perma-Fix Environmental Services, Inc. Chief Operating Officer Larry McNamara is the 2007 recipient of the distinguished Richard S. Hodes, M.D. Honor Lecture Award from the Southeast Compact Commission for Low-Level Radioactive Waste Management. This award recognizes Mr. McNamara's innovation in the commercialization of mixed waste treatment processes for the nuclear industry, and the significant role that these innovations have played solving low-level radioactive waste (LLRW) management problems in the United States with specific emphasis on low-level mixed wastes. Low-level mixed wastes (LLMW) have historically been the most difficult wastes to treat because of the specialized equipment, permits and experience neededmore » to deal with a large variety of hazardous constituents. Prior to innovations in the mixed waste treatment industry championed by Mr. McNamara, wastes were stored at generator sites around the country in regulated storage areas, at great cost, and in many cases for decades. In this paper, Mr. McNamara shares lessons he has learned over the past seven years in developing and implementing innovative waste management solutions that have helped solve one of the nation's biggest challenges. He also describes the future challenges facing the industry. (authors)« less

  7. Role of Pumped Storage Hydro Resources in Electricity Markets and System Operation: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ela, E.; Kirby, B.; Botterud, A.

    2013-05-01

    The most common form of utility- sized energy storage system is the pumped storage hydro system. Originally, these types of storage systems were economically viable simply because they displace more expensive generating units. However, over time, as those expensive units became more efficient and costs declined, pumped hydro storage units no longer have the operational edge. As a result, in the current electricity market environment, pumped storage hydro plants are struggling. To offset this phenomenon, certain market modifications should be addressed. This paper will introduce some of the challenges faced by pumped storage hydro plants in today's markets and purposemore » some solutions to those problems.« less

  8. Properties of zirconia after plasma treatment

    NASA Astrophysics Data System (ADS)

    Alekseenko, V. P.; Kulkov, S. N.

    2017-09-01

    The influence of high-frequency plasma treatment on the properties of zirconia powder is shown in the work. The powder was produced by a plasma-chemical method. The powders had a foamy form with the size of agglomerates of 5-10 μm and crystallites of 20-50 nm. The powders were treated by the pulse plasma unit with dielectric barrier discharge generator. It was shown that the plasma processing changes the acidity of water-powder suspensions from 8.1 to 4.3 pH, which signifies the powders' wettability improvement. It was revealed that more intensive mixing using ultrasound influences the acidity level, reducing it in comparison with mixing by paddle-type agitator. It was shown that these changes of surface properties have relaxation by 4% per day and extrapolation of this dependence shows that the powder will have initial properties after 400 hours storage at room conditions.

  9. Evapotranspiration response to multi-year dry periods in the semi-arid western United States

    NASA Astrophysics Data System (ADS)

    Rungee, J. P., II; Bales, R. C.

    2017-12-01

    Analysis of measured evapotranspiration shows multi-year regolith water storage can support evapotranspiration for years into a multi-year dry period. Measurements at 25 flux-tower sites in the semi-arid western United States, distributed across five primary land-cover types, show both resilience and vulnerability to multi-year dry periods. Average evapotranspiration ranged from about 700+200 mm per water year (October-September) in evergreen needleleaf forests to 350+150 mm per water year in grasslands and open shrublands. On average, in California's Mediterranean climate almost half of the water-year evapotranspiration is supported by seasonal and/or multi-year regolith water storage, compared to a characteristic 20 to 30 percent value of energy-limited and inland sites. Below 35oN latitude, water-year evapotranspiration exceeded estimated precipitation in over half of the years on record. For non-energy-limited sites, water-year evapotranspiration increased with precipitation up to a maximum water-year evapotranspiration value of about 900, 750, 600, 425 and 300 mm per water year for evergreen needleleaf forests, mixed forests, woody savannas, grasslands and open shrublands, respectively. There were 15 multi-year dry periods on record that exhibited either an attenuation in evapotranspiration, defined as an annual value below 80% of the wet-year average, or withdrawal from multi-year storage. A multi-year dry period was defined as three or more consecutive water years in which all water-year precipitation values and the mean period value were in the lower 50 and 35 percent of the historical record, respectively. For sites exhibiting evapotranspiration attenuation, resistance to multi-year dry periods ranged from 9 to 49 months, drafting as much as 444 mm of regolith storage. At some mountain sites regolith storage provided up to 678 mm, almost the equivalent of the average water-year evapotranspiration for these sites, over the extent of the multi-year dry period.

  10. Do storage dynamics in hydropedological units control hydrological connectivity? (Invited)

    NASA Astrophysics Data System (ADS)

    Tetzlaff, D.; Birkel, C.; Dick, J.; Geris, J.; Soulsby, C.

    2013-12-01

    In many northern landscapes, peat-dominated riparian wetlands often characterise the zone of connection between terrestrial drainage and the river network. In order to understand the relationship between connectivity and stream flow generation in a montane headwater catchment, we examined the storage dynamics and isotopic composition of soil water in major hydropedological units. These formed a classic catena sequence for northern catchments from free-draining podzols on steep upper hillslopes through to peaty gleysols in lower receiving slopes to deeper peats (Histosols) in the riparian zone. The peaty gleys and peats remained saturated throughout the year, whilst the podzols showed distinct wetting and drying cycles. In this climatic region, most precipitation events are less than 10mm in magnitude, storm runoff is mainly generated from the Histosols and Gleysols, with runoff coefficients (RCs) typically <10%. In larger events the podzolic soils become strongly connected to the saturated areas and RCs can exceed 40%. Isotopic variations in precipitation are significantly damped in the organic-rich surface horizons of the soils due to mixing with larger volumes of stored water. This damping is accentuated in the deeper soil profile and groundwater. Consequently, the isotopic composition of stream water is also damped, but the strongly reflects that of the near surface waters in the riparian peats. Old 'pre-event' water generally accounts for >80% of flow, even in large events, mainly reflecting the displacement of water stored in the riparian peats and peaty gleys. These riparian areas appear to be the dominant zone where different catchment source waters mix; acting as an 'isostat' that regulates the isotopic composition of stream waters and integrates the Transit Time Distribution (TTD) for the catchment.

  11. Evaporative cooling enhanced cold storage system

    DOEpatents

    Carr, Peter

    1991-01-01

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.

  12. Evaporative cooling enhanced cold storage system

    DOEpatents

    Carr, P.

    1991-10-15

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

  13. Long-Term Effects on Graphene Supercapacitors of Using a Zirconia Bowl and Zirconia Balls for Ball-Mill mixing of Active Materials

    NASA Astrophysics Data System (ADS)

    Song, Dae-Hoon; Kim, Jin-Young; Kahng, Yung Ho; Cho, Hoonsung; Kim, Eung-Sam

    2018-04-01

    Improving the energy storage performance of supercapacitor electrodes based on reduced graphene oxide (RGO) is one of the main subjects in this research field. However, when a zirconia bowl and zirconia balls were used for ball-mill mixing of the active materials for RGO supercapacitors, the energy storage performance deteriorated over time. Our study revealed that the source of the problem was the inclusion of zirconia bits from abrasion of the bowl and the balls during the ballmill mixing, which increased during a period of 1 year. We probed two solutions to this problem: 1) hydrofluoric (HF) acid treatment of the RGO supercapacitors and 2) use of a tempered steel bowl and tempered steel balls for the mixing. For both cases, the energy storage performance was restored to near the initial level, showing a specific capacitance ( C sp ) of 200 F/g. Our results should lead to progress in research on RGO supercapacitors.

  14. Timescales of mixing and storage for Keanakāko`i Tephra magmas (1500-1820 C.E.), Kīlauea Volcano, Hawai`i

    NASA Astrophysics Data System (ADS)

    Lynn, Kendra J.; Garcia, Michael O.; Shea, Thomas; Costa, Fidel; Swanson, Donald A.

    2017-09-01

    The last 2500 years of activity at Kīlauea Volcano (Hawai`i) have been characterized by centuries-long periods dominated by either effusive or explosive eruptions. The most recent period of explosive activity produced the Keanakāko`i Tephra (KT; ca. 1500-1820 C.E.) and occurred after the collapse of the summit caldera (1470-1510 C.E.). Previous studies suggest that KT magmas may have ascended rapidly to the surface, bypassing storage in crustal reservoirs. The storage conditions and rapid ascent hypothesis are tested here using chemical zoning in olivine crystals and thermodynamic modeling. Forsterite contents (Fo; [Mg/(Mg + Fe) × 100]) of olivine core and rim populations are used to identify melt components in Kīlauea's prehistoric (i.e., pre-1823) plumbing system. Primitive (≥Fo88) cores occur throughout the 300+ years of the KT period; they originated from mantle-derived magmas that were first mixed and stored in a deep crustal reservoir. Bimodal olivine populations (≥Fo88 and Fo83-84) record repeated mixing of primitive magmas and more differentiated reservoir components shallower in the system, producing a hybrid composition (Fo85-87). Phase equilibria modeling using MELTS shows that liquidus olivine is not stable at depths >17 km. Thus, calculated timescales likely record mixing and storage within the crust. Modeling of Fe-Mg and Ni zoning patterns (normal, reverse, complex) reveal that KT magmas were mixed and stored for a few weeks to several years before eruption, illustrating a more complex storage history than direct and rapid ascent from the mantle as previously inferred for KT magmas. Complexly zoned crystals also have smoothed compositional reversals in the outer 5-20 µm rims that are out of Fe-Mg equilibrium with surrounding glasses. Diffusion models suggest that these rims formed within a few hours to a few days, indicating that at least one additional, late-stage mixing event may have occurred shortly prior to eruption. Our study illustrates that the lifetimes of KT magmas are more complex than previously proposed, and that most KT magmas did not rise rapidly from the mantle without modification during shallow crustal storage.

  15. Is the whole the sum of its parts? Agent-based modelling of wastewater treatment systems.

    PubMed

    Schuler, A J; Majed, N; Bucci, V; Hellweger, F L; Tu, Y; Gu, A Z

    2011-01-01

    Agent-based models (ABMS) simulate individual units within a system, such as the bacteria in a biological wastewater treatment system. This paper outlines past, current and potential future applications of ABMs to wastewater treatment. ABMs track heterogeneities within microbial populations, and this has been demonstrated to yield different predictions of bulk behaviors than the conventional, "lumped" approaches for enhanced biological phosphorus removal (EBPR) completely mixed reactors systems. Current work included the application of the ABM approach to bacterial adaptation/evolution, using the model system of individual EBPR bacteria that are allowed to evolve a kinetic parameter (maximum glycogen storage) in a competitive environment. The ABM approach was successfully implemented to a simple anaerobic-aerobic system and it was found the differing initial states converged to the same optimal solution under uncertain hydraulic residence times associated with completely mixed hydraulics. In another study, an ABM was developed and applied to simulate the heterogeneity in intracellular polymer storage compounds, including polyphosphate (PP), in functional microbial populations in enhanced biological phosphorus removal (EBPR) process. The simulation results were compared to the experimental measurements of single-cell abundance of PP in polyphosphate accumulating organisms (PAOs), performed using Raman microscopy. The model-predicted heterogeneity was generally consistent with observations, and it was used to investigate the relative contribution of external (different life histories) and internal (biological) mechanisms leading to heterogeneity. In the future, ABMs could be combined with computational fluid dynamics (CFD) models to understand incomplete mixing, more intracellular states and mechanisms can be incorporated, and additional experimental verification is needed.

  16. Wildfire and drought dynamics destabilize carbon stores of fire-suppressed forests.

    PubMed

    Earles, J Mason; North, Malcolm P; Hurteau, Matthew D

    2014-06-01

    Widespread fire suppression and thinning have altered the structure and composition of many forests in the western United States, making them more susceptible to the synergy of large-scale drought and fire events. We examine how these changes affect carbon storage and stability compared to historic fire-adapted conditions. We modeled carbon dynamics under possible drought and fire conditions over a 300-year simulation period in two mixed-conifer conditions common in the western United States: (1) pine-dominated with an active fire regime and (2) fir-dominated, fire suppressed forests. Fir-dominated stands, with higher live- and dead-wood density, had much lower carbon stability as drought and fire frequency increased compared to pine-dominated forest. Carbon instability resulted from species (i.e., fir's greater susceptibility to drought and fire) and stand (i.e., high density of smaller trees) conditions that develop in the absence of active management. Our modeling suggests restoring historic species composition and active fire regimes can significantly increase carbon stability in fire-suppressed, mixed-conifer forests. Long-term management of forest carbon should consider the relative resilience of stand structure and composition to possible increases in disturbance frequency and intensity under changing climate.

  17. Solar applications analysis for energy storage

    NASA Technical Reports Server (NTRS)

    Blanchard, T.

    1980-01-01

    The role of energy storage as it relates to solar energy systems is considered. Storage technologies to support solar energy applications, the status of storage technologies, requirements and specifications for storage technologies, and the adequacy of the current storage research and development program to meet these requirements are among the factors discussed. Emphasis is placed on identification of where the greatest potential exists for energy storage in support of those solar energy systems which could have a significant impact on the U.S. energy mix.

  18. An improved red blood cell additive solution maintains 2,3-diphosphoglycerate and adenosine triphosphate levels by an enhancing effect on phosphofructokinase activity during cold storage.

    PubMed

    Burger, Patrick; Korsten, Herbert; De Korte, Dirk; Rombout, Eva; Van Bruggen, Robin; Verhoeven, Arthur J

    2010-11-01

    Current additive solutions (ASs) for red blood cells (RBCs) do not maintain constant 2,3-diphosphoglycerate (DPG) and adenosine triphosphate (ATP) levels during cold storage. We have previously shown that with a new AS called phosphate-adenine-glucose-guanosine-gluconate-mannitol (PAGGGM), both 2,3-DPG and ATP could be maintained throughout storage for 35 days. In this study, the mechanism underlying the effect of PAGGGM on RBC storage was studied in more detail. By using double-erythrocytapheresis units (leukoreduced), a direct comparison could be made between the current AS saline-adenine-glucose-mannitol (SAGM) and the experimental solution PAGGGM. During cold storage, several in vitro characteristics were analyzed. In agreement with our previous findings with single RBCs, PAGGGM maintained 2,3-DPG and ATP levels for 35 days of cold storage. Furthermore, glucose consumption and lactate production were higher in PAGGGM units during the first 21 days of cold storage. Fructose-1,6-diphophate and dihydroxyacetone phosphate levels were also increased during the first 21 days of storage in PAGGGM units. These results indicate that it is likely that phosphofructokinase (PFK) activity is enhanced in PAGGGM units relative to SAGM units. After 21 days, PFK activity also decreases in PAGGGM units, but sufficient metabolic reserve in these units prevents depletion of 2,3-DPG and ATP. © 2010 American Association of Blood Banks.

  19. 24 CFR 3286.11 - Temporary storage of units.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...

  20. 24 CFR 3286.11 - Temporary storage of units.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...

  1. 24 CFR 3286.11 - Temporary storage of units.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...

  2. [Carbon storage of forest vegetation and allocation for main forest types in the east of Da-xing'an Mountains based on additive biomass model].

    PubMed

    Peng, Wei; Dong, Li Hu; Li, Feng Ri

    2016-12-01

    Based on the biomass investigation data of main forest types in the east of Daxing'an Mountains, the additive biomass models of 3 main tree species were developed and the changes of carbon storage and allocation of forest community of tree layer, shrub layer, herb layer and litter layer from different forest types were discussed. The results showed that the carbon storage of tree layer, shrub layer, herb layer and litter layer for Rhododendron dauricum-Larix gmelinii forest was 71.00, 0.34, 0.05 and 11.97 t·hm -2 , respectively. Similarly, the carbon storage of the four layers of Ledum palustre-L. gmelinii forest was 47.82, 0.88, 0, 5.04 t·hm -2 , 56.56, 0.44, 0.04, 8.72 t·hm -2 for R. dauricum-mixed forest of L. gmelinii-Betula platyphylla, 46.21, 0.66, 0.07, 6.16 t·hm -2 for L. palustre-mixed forest of L. gmelinii-B. platyphylla, 40.90, 1.37, 0.04, 3.67 t·hm -2 for R. dauricum-B. platyphylla forest, 36.28, 1.12, 0.18, 4.35 t·hm -2 for L. palustre-B. platyphylla forest. The carbon storage of forest community for the understory vegetation of R. dauricum was higher than that of the forest with L. palustre. In the condition of similar circumstances for the understory, the order of carbon storage for forest community was L. gmelinii forest > the mixed forest of L. gmelinii-B. platyphylla > B. platyphylla forest. The carbon storage of different forest types was different with the order of R. dauricum-L. gmelinii forest (83.36 t·hm -2 )> R. dauricum-mixed forest of L. gmelinii-B. platyphylla (65.76 t·hm -2 ) > L. palustre-L. gmelinii forest (53.74 t·hm -2 )> L. palustre-mixed forest of L. gmelinii-B. platyphylla (53.10 t·hm -2 )> R. dauricum-B. platyphylla forest (45.98 t·hm -2 ) > L. palustre-B. platyphylla forest (41.93 t·hm -2 ). The order of carbon storage for the vertical distribution in forest communities with diffe-rent forest types was the tree layer (85.2%-89.0%) > litter layer (8.0%-14.4%) > shrub layer (0.4%-2.7%) > herb layer (0-0.4%).

  3. Variation in temperature and mechanical properties of asphaltic concrete due to storage in surge bins.

    DOT National Transportation Integrated Search

    1973-03-01

    The Louisiana Department of Highways specifications on asphaltic concrete allow the contractors to use silos or surge bins for storage of asphaltic concrete mixtures. However, the maximum allowable storage time of the hot mix, if the contractor elect...

  4. 40 CFR 63.1360 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... process unit. If the greatest input to and/or output from a shared storage vessel is the same for two or... not have an intervening storage vessel. If two or more PAI process units have the same input to or... process unit that sends the most material to or receives the most material from the storage vessel. If two...

  5. Effects of Storage Time on Glycolysis in Donated Human Blood Units

    PubMed Central

    Qi, Zhen; Roback, John D.; Voit, Eberhard O.

    2017-01-01

    Background: Donated blood is typically stored before transfusions. During storage, the metabolism of red blood cells changes, possibly causing storage lesions. The changes are storage time dependent and exhibit donor-specific variations. It is necessary to uncover and characterize the responsible molecular mechanisms accounting for such biochemical changes, qualitatively and quantitatively; Study Design and Methods: Based on the integration of metabolic time series data, kinetic models, and a stoichiometric model of the glycolytic pathway, a customized inference method was developed and used to quantify the dynamic changes in glycolytic fluxes during the storage of donated blood units. The method provides a proof of principle for the feasibility of inferences regarding flux characteristics from metabolomics data; Results: Several glycolytic reaction steps change substantially during storage time and vary among different fluxes and donors. The quantification of these storage time effects, which are possibly irreversible, allows for predictions of the transfusion outcome of individual blood units; Conclusion: The improved mechanistic understanding of blood storage, obtained from this computational study, may aid the identification of blood units that age quickly or more slowly during storage, and may ultimately improve transfusion management in clinics. PMID:28353627

  6. Effects of Storage Time on Glycolysis in Donated Human Blood Units.

    PubMed

    Qi, Zhen; Roback, John D; Voit, Eberhard O

    2017-03-29

    Background : Donated blood is typically stored before transfusions. During storage, the metabolism of red blood cells changes, possibly causing storage lesions. The changes are storage time dependent and exhibit donor-specific variations. It is necessary to uncover and characterize the responsible molecular mechanisms accounting for such biochemical changes, qualitatively and quantitatively; Study Design and Methods : Based on the integration of metabolic time series data, kinetic models, and a stoichiometric model of the glycolytic pathway, a customized inference method was developed and used to quantify the dynamic changes in glycolytic fluxes during the storage of donated blood units. The method provides a proof of principle for the feasibility of inferences regarding flux characteristics from metabolomics data; Results : Several glycolytic reaction steps change substantially during storage time and vary among different fluxes and donors. The quantification of these storage time effects, which are possibly irreversible, allows for predictions of the transfusion outcome of individual blood units; Conclusion : The improved mechanistic understanding of blood storage, obtained from this computational study, may aid the identification of blood units that age quickly or more slowly during storage, and may ultimately improve transfusion management in clinics.

  7. Hydrologic and Geochemical Evaluation of Aquifer Storage Recovery in the Santee Limestone/Black Mingo Aquifer, Charleston, South Carolina, 1998-2002

    USGS Publications Warehouse

    Petkewich, Matthew D.; Parkhurst, David L.; Conlon, Kevin J.; Campbell, Bruce G.; Mirecki, June E.

    2004-01-01

    The hydrologic and geochemical effects of aquifer storage recovery were evaluated to determine the potential for supplying the city of Charleston, South Carolina, with large quantities of potable water during emergencies, such as earthquakes, hurricanes, or hard freezes. An aquifer storage recovery system, including a production well and three observation wells, was installed at a site located on the Charleston peninsula. The focus of this study was the 23.2-meter thick Tertiary-age carbonate and sand aquifer of the Santee Limestone and the Black Mingo Group, the northernmost equivalent of the Floridan aquifer system. Four cycles of injection, storage, and recovery were conducted between October 1999 and February 2002. Each cycle consisted of injecting between 6.90 and 7.19 million liters of water for storage periods of 1, 3, or 6 months. The volume of recovered water that did not exceed the U.S. Environmental Protection Agency secondary standard for chloride (250 milligrams per liter) varied from 1.48 to 2.46 million liters, which is equivalent to 21 and 34 percent of the total volume injected for the individual tests. Aquifer storage recovery testing occurred within two productive zones of the brackish Santee Limestone/Black Mingo aquifer. The individual productive zones were determined to be approximately 2 to 4 meters thick, based on borehole geophysical logs, electromagnetic flow-meter testing, and specific-conductance profiles collected within the observation wells. A transmissivity and storage coefficient of 37 meters squared per day and 3 x 10-5, respectively, were determined for the Santee Limestone/Black Mingo aquifer. Water-quality and sediment samples collected during this investigation documented baseline aquifer and injected water quality, aquifer matrix composition, and changes in injected/aquifer water quality during injection, storage, and recovery. A total of 193 water-quality samples were collected and analyzed for physical properties, major and minor ions, and nutrients. The aquifer and treated surface water were sodiumchloride and calcium/sodium-bicarbonate water types, respectively. Forty-five samples were collected and analyzed for total trihalomethane. Total trihalomethane data collected during aquifer storage recovery cycle 4 indicated that this constituent would not restrict the use of recovered water for drinking-water purposes. Analysis of six sediment samples collected from a cored well located near the aquifer storage recovery site showed that quartz and calcite were the dominant minerals in the Santee Limestone/Black Mingo aquifer. Estimated cation exchange capacity ranged from 12 to 36 milliequivalents per 100 grams in the lower section of the aquifer. A reactive transport model was developed that included two 2-meter thick layers to describe each of the production zones. The four layers composing the production zones were assigned porosities ranging from 0.1 to 0.3 and hydraulic conductivities ranging from 1 to 8.4 meters per day. Specific storage of the aquifer and confining units was estimated to be 1.5 x 10-5 meter-1. Longitudinal dispersivity of all layers was specified to be 0.5 meter. Leakage through the confining unit was estimated to be minimal and, therefore, not used in the reactive transport modeling. Inverse geochemical modeling indicates that mixing, cation exchange, and calcite dissolution are the dominant reactions that occur during aquifer storage recovery testing in the Santee Limestone/Black Mingo aquifer. Potable water injected into the Santee Limestone/Black Mingo aquifer evolved chemically by mixing with brackish background water and reaction with calcite and cation exchangers in the sediment. Reactive-transport model simulations indicated that the calcite and exchange reactions could be treated as equilibrium processes. Simulations with the calibrated reactive transport model indicated that approximately one-fourth of the total volume of water injected into

  8. Numerical analysis of single tank thermocline thermal storage system for concentrated solar power plant

    NASA Astrophysics Data System (ADS)

    Afrin, Samia

    The overall efficiency of a Concentrating Solar Power (CSP) plant depends on the effectiveness of Thermal Energy Storage (TES) system. A Single tank TES system has potential to provide effective solution. In a single tank TES system, a thermocline region, which produces the temperature gradient between hot and cold storage fluid by density difference, is used. Preservation of this thermocline region in the tank during charging and discharging cycles depends on the uniformity of the velocity profile at any horizontal plane. One of the major challenges for the single tank thermocline is actually maintaining the thermocline region in the tank, so that it does not spread out to occupy the entire tank. Since the thermocline is a horizontal surface, the hot and cold fluid must be introduce in such a way that it does not disturb the thermocline. If the fluid is introduced in a jet stream, it will disturb the thermocline and mix the hot and cold fluids into a homogeneous medium. So the objective of this thesis is to preserve the thermocline region by maximizing the uniformity of the velocity distribution. An ideal distributor will minimize the thermocline spreading and hence maximize the useable form of thermal energy storage in a single tank system. The performance of two different types of distributors: pipe flow distributor and honeycomb distributor, were checked. The effectiveness of the pipe flow distributor was checked by varying the dimension of the geometry i.e. number of holes, distance between the holes, position of the holes and number of distributor pipes. Thermal energy storage system from solar power relies on high temperature thermal storage units for continuous operation. The storage units should have facilitated with high thermal conductivity and heat capacity storage fluid. Hence it is necessary to find a better performing heat transfer fluid at higher operating temperature. Novel materials such as nanomaterial additives can become cost effective and can increase the operating range of the storage facilities to higher range of temperatures. In this work HitecRTM molten salt is considered as the heat transfer fluid (HTF). The operating temperature of this HTF is 300-500°C. So to increase the thermal properties of this HTF nanomaterial has been added. The effective thermal conductivity and specific heat capacity of the nanofluid were calculated and the thermal effect of this nanofluid was observed from the simulation result.

  9. Effects of Formation Heterogeneity in Semi-Confining Shale Layers in Enhancing Mixing and Storage of Dissolved CO2

    NASA Astrophysics Data System (ADS)

    Illangasekare, T. H.; Agartan Karacaer, E.; Vargas-Johnson, J.; Cihan, A.; Birkholzer, J. T.

    2017-12-01

    It is expected that heterogeneity of the deep geologic formation to play a key role in both trapping of supercritical CO2 and its mixing in the formation brine. In previously reported research by the authors, a set of laboratory experiments and field-scale simulations were used to show that convective mixing and diffusion controlled trapping are two important mechanisms that contribute to the dissolution trapping in multilayered systems with homogeneous low-permeability zones such as shale. However, these low-permeability layers (e.g. shale) are not always homogeneous due to their composition and texture variations in addition to the presence of faults, fractures and fissures. In this study, we investigated the potential outcomes of heterogeneity present within these semi-confining low-permeability layers in regards to mixing and storage of dissolved CO2. An intermediate-scale laboratory experiment was designed to investigate the contribution of convective mixing, diffusion controlled trapping and back diffusion to long-term storage of dissolved CO2 in multilayered formations with heterogeneous low-permeability layers. The experiment was performed using a surrogate fluid combination to represent dissolved CO2 and brine under ambient pressure and temperature conditions. After verifying the numerical model with the experimental results, different distributions of the same low-permeability materials having similar volume ratios with the experimentally studied scenario were tested numerically. The experiment and modeling results showed that connectivity of higher permeability material within the semi-confining low-permeability layers contributes to mixing through brine leakage between upper and lower aquifers, storage through diffusion, and in the long term, back diffusion of stored mass due to reversed concentration gradient.

  10. Effects of Formic or Acetic Acid on the Storage Quality
 of Mixed Air-Dried Corn Stover and Cabbage Waste,
and Microbial Community Analysis.

    PubMed

    Ren, Haiwei; Wang, Cong; Fan, Wenguang; Zhang, Bingyun; Li, Zhizhong; Li, Dong

    2018-03-01

    A mixture of air-dried corn stover and cabbage waste was ensiled to preserve lignocellulosic biomass for use as biofuel. Furthermore, the effects of different fresh mass fractions (0.3 and 0.6%) of formic or acetic acid on the mixed silage quality were evaluated to guarantee its quality. The application of formic or acetic acid prior to mixing the silage led to higher water-soluble carbohydrate fractions than the negative control, indicating that both acids contributed to preservation of water-soluble carbohydrates during storage for 170 days. The dry matter content was also increased after storage from 90 to 170 days. It was found that the content of neutral and acid detergent fibre, cellulose and holocellulose (the sum of cellulose and hemicellulose) in mixed silage treated with formic or acetic acid was significantly lower than that obtained in the negative control. The pH and the ratio of ammoniacal nitrogen to total nitrogen in mixed silage treated with acetic acid also significantly decreased. Furthermore, the addition of formic or acetic acid significantly weakened the fermentation intensity of lactic acid, depending on the ratio of lactic to acetic acid, as well as the ratio of lactic acid to total organic acids. The number of bacterial species and their relative abundance shifted during silage mixing, wherein microbial communities at phylum level mainly consisted of Proteobacteria and Firmicutes. The dominant bacteria were also observed to shift from Lactobacillus and Enterobacter in presilage biomass to Lactobacillus and Paralactobacillus . Specifically, Enterobacter disappeared after 130 days of storage. In conclusion, the addition of a low dose of acetic acid to fresh mass (0.3%) could effectively improve the fermentation quality and is conducive to the preservation of the organic components.

  11. MIXING IN DISTRIBUTION SYSTEM STORAGE TANKS: ITS EFFECT ON WATER QUALITY

    EPA Science Inventory

    Nearly all distribution systems in the US include storage tanks and reservoirs. They are the most visible components of a wate distribution system but are generally the least understood in terms of their impact on water quality. Long residence times in storage tanks can have nega...

  12. Shelving Maximizes Storage and Productivity.

    ERIC Educational Resources Information Center

    School Business Affairs, 1984

    1984-01-01

    Describes specialized units that increase storage capacity. One involves two stationary units at either end of a track, with three or more movable units and one aisle; the other is an inclined rack. (MLF)

  13. FY 17 Q1 Commercial integrated heat pump with thermal storage milestone report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abu-Heiba, Ahmad; Baxter, Van D.; Shen, Bo

    2017-01-01

    The commercial integrated heat pump with thermal storage (AS-IHP) offers significant energy saving over a baseline heat pump with electric water heater. The saving potential is maximized when the AS-IHP serves coincident high water heating and high space cooling demands. A previous energy performance analysis showed that the AS-IHP provides the highest benefit in the hot-humid and hot-dry/mixed dry climate regions. Analysis of technical potential energy savings for these climate zones based on the BTO Market calculator indicated that the following commercial building market segments had the highest water heating loads relative to space cooling and heating loads education, foodmore » service, health care, lodging, and mercantile/service. In this study, we focused on these building types to conservatively estimate the market potential of the AS-IHP. Our analysis estimates maximum annual shipments of ~522,000 units assuming 100% of the total market is captured. An early replacement market based on replacement of systems in target buildings between 15 and 35 years old was estimated at ~136,000 units. Technical potential energy savings are estimated at ~0.27 quad based on the maximum market estimate, equivalent to ~13.9 MM Ton CO2 emissions reduction.« less

  14. Red blood cell storage duration and long-term mortality in patients undergoing cardiac intervention: a Danish register study.

    PubMed

    Dencker, D; Pedersen, F; Engstrøm, T; Schroeder, T V; Lönn, L; Johansson, P I; De Backer, O

    2017-08-01

    To study the effect of red blood cell (RBC) storage duration on long-term mortality in patients undergoing cardiac intervention. RBCs undergo numerous structural and functional changes during storage. Observational studies have assessed the association between RBC storage duration and patient outcomes with conflicting results. Between January 2006 and December 2014, 82 408 patients underwent coronary angiography. Of these, 1856 patients received one to four RBC units within 30 days after this procedure. Patients were allocated according to length of RBC storage duration: short-term (≤11 days), intermediate (IM)-term (12-23 days) and long-term (≥24 days). The study endpoints were 30-day and long-term all-cause mortality. A total of 4168 RBC units were given to 1856 patients. The mean RBC storage duration was 8.5 ± 2.1, 17.7 ± 3.4 and 29.9 ± 3.4 days in the short-term, IM-term and long-term storage groups, respectively. There was no difference in baseline characteristics between the groups. The long-term storage group received significantly more units (2.4 ± 1.0 units) as compared to the short-term (2.0 ± 1.0 units; P < 0.001) and IM-term storage group (2.2 ± 1.0 units; P < 0.01). In the survival analysis, there was no significant difference in all-cause mortality between the groups (log-rank: 0.509 for 30-days mortality; 0.493 for 5-year mortality). Additional stratified analysis demonstrated no association between RBC storage duration and long-term mortality. This study did not find an association between RBC storage duration and 30-days or long-term mortality in patients undergoing cardiac intervention. © 2017 British Blood Transfusion Society.

  15. Performance analysis of phase-change material storage unit for both heating and cooling of buildings

    NASA Astrophysics Data System (ADS)

    Waqas, Adeel; Ali, Majid; Ud Din, Zia

    2017-04-01

    Utilisation of solar energy and the night ambient (cool) temperatures are the passive ways of heating and cooling of buildings. Intermittent and time-dependent nature of these sources makes thermal energy storage vital for efficient and continuous operation of these heating and cooling techniques. Latent heat thermal energy storage by phase-change materials (PCMs) is preferred over other storage techniques due to its high-energy storage density and isothermal storage process. The current study was aimed to evaluate the performance of the air-based PCM storage unit utilising solar energy and cool ambient night temperatures for comfort heating and cooling of a building in dry-cold and dry-hot climates. The performance of the studied PCM storage unit was maximised when the melting point of the PCM was ∼29°C in summer and 21°C during winter season. The appropriate melting point was ∼27.5°C for all-the-year-round performance. At lower melting points than 27.5°C, declination in the cooling capacity of the storage unit was more profound as compared to the improvement in the heating capacity. Also, it was concluded that the melting point of the PCM that provided maximum cooling during summer season could be used for winter heating also but not vice versa.

  16. A highly reliable cryogenic mixing pump with no mechanical moving parts

    NASA Astrophysics Data System (ADS)

    Chen, W.; Niblick, A. L.

    2017-12-01

    This paper presents the design and preliminary test results of a novel cryogenic mixing pump based on magnetocaloric effect. The mixing pump is developed to enable long-term cryogenic propellant storage in space by preventing thermal stratification of cryogens in storage tanks. The mixing pump uses an innovative thermodynamic process to generate fluid jets to promote fluid mixing, eliminating the need for mechanical pumps. Its innovative mechanism uses a solid magnetocaloric material to alternately vaporize and condense the cryogen in the pumping chamber, and thus control the volume of the fluid inside the pumping chamber to produce pumping action. The pump is capable of self-priming and can generate a high-pressure rise. This paper discusses operating mechanism and design consideration of the pump, introduces the configuration of a brassboard cryogenic pump, and presents the preliminary test results of the pump with liquid nitrogen.

  17. Mixed Oxidant Process for Control of Biological Growth in Cooling Towers

    DTIC Science & Technology

    2010-02-01

    Concentration is < 1% (vs. 12.5% for bulk bleach ) • Will not form chlorine gas • No transport or storage of hazardous chemicals • Uses only salt as...Eliminates purchase, transport, and storage of hazardous biocide compounds such as hypochlorite or chlorine gas • Provides a constant dosage level of...patented MIOX equipment design • Chemical and biocidal properties are more effective than conventional chlorine Bulk Bleach On-Site Hypo Mixed Oxidants E

  18. Hysteresis and parent-metabolite analyses unravel characteristic pesticide transport mechanisms in a mixed land use catchment.

    PubMed

    Tang, Ting; Stamm, Christian; van Griensven, Ann; Seuntjens, Piet; Bronders, Jan

    2017-11-01

    To properly estimate and manage pesticide occurrence in urban rivers, it is essential, but often highly challenging, to identify the key pesticide transport pathways in association to the main sources. This study examined the concentration-discharge hysteresis behaviour (hysteresis analysis) for three pesticides and the parent-metabolite concentration dynamics for two metabolites at sites with different levels of urban influence in a mixed land use catchment (25 km 2 ) within the Swiss Greifensee area, aiming to identify the dominant pesticide transport pathways. Combining an adapted hysteresis classification framework with prior knowledge of the field conditions and pesticide usage, we demonstrated the possibility of using hysteresis analysis to qualitatively infer the dominant pesticide transport pathway in mixed land-use catchments. The analysis showed that hysteresis types, and therefore the dominant transport pathway, vary among pesticides, sites and rainfall events. Hysteresis loops mostly correspond to dominant transport by flow components with intermediate response time, although pesticide sources indicate that fast transport pathways are responsible in most cases (e.g. urban runoff and combined sewer overflows). The discrepancy suggests the fast transport pathways can be slowed down due to catchment storages, such as topographic depressions in agricultural areas, a wastewater treatment plant (WWTP) and other artificial storage units (e.g. retention basins) in urban areas. Moreover, the WWTP was identified as an important factor modifying the parent-metabolite concentration dynamics during rainfall events. To properly predict and manage pesticide occurrence in catchments of mixed land uses, the hydrological delaying effect and chemical processes within the artificial structures need to be accounted for, in addition to the catchment hydrology and the diversity of pesticide sources. This study demonstrates that in catchments with diverse pesticide sources and complex transport mechanisms, the adapted hysteresis analysis can help to improve our understanding on pesticide transport behaviours and provide a basis for effective management strategies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Comparative geomorphic analysis of surficial deposits at three central Appalachian watersheds: Implications for controls on sediment-transport efficiency

    NASA Astrophysics Data System (ADS)

    Taylor, Stephen B.; Steven Kite, J.

    2006-08-01

    Factors that control the routing and storage of sediments in the Appalachian region are poorly understood. This study involves a comparative geomorphic analysis of three watersheds underlain by sandstones and shales of the Acadian clastic wedge. These areas include the Fernow Experimental Forest, Tucker County, West Virginia; the North Fork basin, Pocahontas County, West Virginia; and the Little River basin, Augusta County, Virginia. GIS-based analyses of surficial map units allow first-order approximation of sediment-storage volumes in valley bottoms. Estimates of volumes are examined in tandem with morphometric analyses and the distribution of bedrock channels to make inferences regarding controls on sediment-transport efficiency in the central Appalachians. The Fernow and North Fork areas are characterized by V-shaped valleys with mixed reaches of alluvial-bedrock channels distributed throughout the drainage network. In contrast, the Little River valley is notably wider and gravelly alluvial fill is abundant. Comparator watershed parameters for the Fernow, North Fork and Little River areas include, respectively: (1) basin area = 15.2 km 2, 49.3 km 2, 41.5 km 2; (2) basin relief = 0.586 km, 0.533 km, 0.828 km; (3) drainage density = 4.2 km - 1 , 3.3 km - 1 , 4.7 km - 1 ; (4) ruggedness = 2.5, 1.7, 3.9; (5) Shreve magnitude = 139, 287, 380; (6) total valley-bottom area (km 2) = 0.76 km 2, 1.86 km 2, 3.09 km 2; (7) average hillslope gradients = 17.2°, 18.4°, 22.1°; (8) total debris-fan surface area = 0.113 km 2, 0.165 km 2, 0.486 km 2; and (9) debris-fan frequency = 2.0 km - 2 , 1.0 km - 2 , 2.8 km - 2 . The storage volumes in valley bottoms were estimated using map polygon areas and surface heights above channel grade. The Little River contains significantly higher sediment volumes in floodplain, terrace and fan storage compartments; total volumes of the valley bottoms are approximately twice that of the Fernow and North Fork areas combined. Unit storage volumes for the Fernow, North Fork and Little River are 5.2 × 10 4 m 3 km - 2 , 5.5 × 10 4 m 3 km - 2 and 1.6 × 10 5 m 3 km - 2 , respectively. A conceptual model postulates that valley-width morphometry and style of delivery from hillslopes are the primary factors controlling the efficiency of sediment transport. Steep, debris-flow-prone hillslopes at the Little River deliver high volumes of gravelly sediment at magnitudes greater than transport capacity of the channel. Patterns of stream power are complex, as low-order tributaries are under capacity and high-order tributaries over capacity with respect to sediment load. Aggraded alluvial fill insulates valley-floor bedrock from vertical erosion and valley widening dominates. Expansion of the valley width creates a positive response via increased storage capacity and lower unit stream power. Conversely, the Fernow and North Fork are characterized by diffusive mass movement on hillslopes with incremental bedload transport to higher-order tributaries. Rates of hillslope delivery are balanced by the rate of channel export. Mixed alluvial-bedrock reaches provide the optimal channel configuration for active incision of the valley floor. Low expansion of valley width promotes high unit stream power and processes of vertical erosion. The model implies that the Fernow and North Fork have been more effective at sediment transport during the Late Quaternary. Given similar climatic and tectonic settings, variation in bedrock lithofacies is likely the primary factor modulating the efficiency of sediment transport.

  20. Hanford facility dangerous waste permit application, PUREX storage tunnels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haas, C. R.

    1997-09-08

    The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to Part B permit application documentation submitted for individual, `operating` treatment, storage, and/or disposal units, such as the PUREX Storage Tunnels (this document, DOE/RL-90-24).

  1. An Isotope-Powered Thermal Storage unit for space applications

    NASA Technical Reports Server (NTRS)

    Lisano, Michael E.; Rose, M. F.

    1991-01-01

    An Isotope-Powered Thermal Storage Unit (ITSU), that would store and utilize heat energy in a 'pulsed' fashion in space operations, is described. Properties of various radioisotopes are considered in conjunction with characteristics of thermal energy storage materials, to evaluate possible implementation of such a device. The utility of the unit is discussed in light of various space applications, including rocket propulsion, power generation, and spacecraft thermal management.

  2. Timing of gamma irradiation and blood donor sex influences in vitro characteristics of red blood cells.

    PubMed

    de Korte, Dirk; Thibault, Louis; Handke, Wiebke; Harm, Sarah K; Morrison, Alex; Fitzpatrick, Aine; Marks, Denese C; Yi, Qi-Long; Acker, Jason P

    2018-04-01

    There are few studies investigating the effect of irradiation on red blood cells (RBCs) during storage. This study analyzed changes in in vitro quality of RBCs irradiated at several points during storage with the aim of providing evidence to support current maximum pre- and postirradiation storage limits. Each of seven participating centers produced four pools of 7 standard RBC units (SAGM, AS-3, or PAGGSM), which were then split back into 7 units. All units in a pool were from sex-matched blood donors. Every week during 6 weeks of refrigerated storage, 1 unit was irradiated, while 1 unit was not irradiated (control). Units were tested weekly for biochemical variables, morphology, and mechanical fragility. The earlier during storage that units were irradiated, the higher the hemolysis and K + at end of storage. Irrespective of the timing of irradiation, there was a rapid increase in extracellular K + , followed by a more gradual increase in hemolysis. ATP levels decreased faster in irradiated units and were reduced below accepted values if irradiated early. Irradiated female RBCs had an absolute lower hemolysis and K + level compared to male RBCs at all time points. The method of blood component manufacturing determined the absolute levels of hemolysis and potassium in irradiated and nonirradiated units, but did not influence the effect that timing of irradiation had on the in vitro quality characteristics. This study provides support for the current Council of Europe guidelines on the time limitations for the irradiation of RBCs. © 2017 AABB.

  3. Centrifugal microfluidic platforms: advanced unit operations and applications.

    PubMed

    Strohmeier, O; Keller, M; Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N

    2015-10-07

    Centrifugal microfluidics has evolved into a mature technology. Several major diagnostic companies either have products on the market or are currently evaluating centrifugal microfluidics for product development. The fields of application are widespread and include clinical chemistry, immunodiagnostics and protein analysis, cell handling, molecular diagnostics, as well as food, water, and soil analysis. Nevertheless, new fluidic functions and applications that expand the possibilities of centrifugal microfluidics are being introduced at a high pace. In this review, we first present an up-to-date comprehensive overview of centrifugal microfluidic unit operations. Then, we introduce the term "process chain" to review how these unit operations can be combined for the automation of laboratory workflows. Such aggregation of basic functionalities enables efficient fluidic design at a higher level of integration. Furthermore, we analyze how novel, ground-breaking unit operations may foster the integration of more complex applications. Among these are the storage of pneumatic energy to realize complex switching sequences or to pump liquids radially inward, as well as the complete pre-storage and release of reagents. In this context, centrifugal microfluidics provides major advantages over other microfluidic actuation principles: the pulse-free inertial liquid propulsion provided by centrifugal microfluidics allows for closed fluidic systems that are free of any interfaces to external pumps. Processed volumes are easily scalable from nanoliters to milliliters. Volume forces can be adjusted by rotation and thus, even for very small volumes, surface forces may easily be overcome in the centrifugal gravity field which enables the efficient separation of nanoliter volumes from channels, chambers or sensor matrixes as well as the removal of any disturbing bubbles. In summary, centrifugal microfluidics takes advantage of a comprehensive set of fluidic unit operations such as liquid transport, metering, mixing and valving. The available unit operations cover the entire range of automated liquid handling requirements and enable efficient miniaturization, parallelization, and integration of assays.

  4. Mixing-induced fluid destratification and ullage condensation

    NASA Technical Reports Server (NTRS)

    Meserole, Jere S.; Jones, Ogden S.; Fortini, Anthony F.

    1987-01-01

    In many applications, on-orbit storage and transfer of cryogens will require forced mixing to control tank pressure without direct venting to space. During a no-vent transfer or during operation of a thermodynamic vent system in a cryogen storage tank, pressure control is achieved by circulating cool liquid to the liquid-vapor interface to condense some of the ullage vapor. To measure the pressure and temperature response rates in mixing-induced condensation, an experiment has been developed using Freon 11 to simulate the two-phase behavior of a cryogen. A thin layer at the liquid surface is heated to raise the tank pressure, and then a jet mixer is turned on to circulate the liquid, cool the surface, and reduce the pressure. Many nozzle configurations and flow rates are used. Tank pressure and the temperature profiles in the ullage and the liquid are measured. Initial data from this ground test are shown correlated with normal-gravity and drop-tower dye-mixing data. Pressure collapse times are comparable to the dye-mixing times, whereas the times needed for complete thermal mixing are much longer than the dye-mixing times.

  5. Parametric design studies of toroidal magnetic energy storage units

    NASA Astrophysics Data System (ADS)

    Herring, J. Stephen

    Superconducting magnetic energy storage (SMES) units have a number of advantages as storage devices. Electrical current is the input, output and stored medium, allowing for completely solid-state energy conversion. The magnets themselves have no moving parts. The round trip efficiency is higher than those for batteries, compressed air or pumped hydro. Output power can be very high, allowing complete discharge of the unit within a few seconds. Finally, the unit can be designed for a very large number of cycles, limited basically by fatigue in the structural components. A small systems code was written to produce and evaluate self-consistent designs for toroidal superconducting energy storage units. The units can use either low temperature or high temperature superconductors. The coils have D shape where the conductor and its stabilizer/structure is loaded only in tension and the centering forces are borne by a bucking cylinder. The coils are convectively cooled from a cryogenic reservoir in the bore of the coils. The coils are suspended in a cylindrical metal shell which protects the magnet during rail, automotive or shipboard use. It is important to note that the storage unit does not rely on its surroundings for structural support, other than normal gravity and inertial loads. Designs are presented for toroidal energy storage units produced by the systems code. A wide range of several parameters have been considered, resulting in units storing from 1 MJ to 72 GJ. Maximum fields range from 5 T to 20 T. The masses and volumes of the coils, bucking cylinder, coolant, insulation and outer shell are calculated. For unattended use, the allowable operating time using only the boiloff of the cryogenic fluid for refrigeration is calculated. For larger units, the coils were divided into modules suitable for normal truck or rail transport.

  6. Comparability of the effect of storage time and temperature on serum anti-Müllerian hormone measurement between original and modified enzyme-linked immunosorbent assay.

    PubMed

    Yue, Chao-Yan; Ying, Chun-Mei

    2017-01-01

    To explore the effect of modified enzyme-linked immunosorbent assay on the AMH results is increased or decreased, and to investigate the effect of storage time and temperature on AMH measurements with and without sample premixing assay buffer using the Kangrun ELISA method. Serum AMH concentration were measured by ELISA, consistency between two kits, and comparability between original and the modified assay under different stored conditions were analyzed by Passing-Bablok regression analysis and Bland-Altman bias evaluation. There was a strong consistency between AMH concentrations measured in Kangrun ELISA and Ansh Labs ultra-sensitive AMH ELISA. Pre-mixing serum specimens with assay buffer gave consistent results compared with original assay. Modified protocol can reduce the amplitude of increase affected by sample aged and give the most consistent results regardless of storage conditions. Pre-mixing protocol did not influence the results of fresh serum or frozen serum incubation <3days at 4°C and -80°C, but when specimens detected after collection and stored in other storage conditions, should be pre-mixed with assay buffer to insure its accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Methane Storage in Biosilica-Supported Semiclathrates at Ambient Temperature and Pressure

    NASA Astrophysics Data System (ADS)

    Li, Liang; Wang, Suying; Wang, Weixing

    2018-01-01

    Two key issues regarding the use of clathrates and semiclathrates for practical gas storage and transport is the pressure-temperature stability of the material and very low formation kinetics. For many practical applications, the avoidance of cooling, gas overpressure, and mechanical mixing would be very desirable. Here, we show that biosilica supports from rice husks greatly enhance gases uptake kinetics in tetra-iso-amyl ammonium bromide semiclathrates without introducing complex mixing technologies. These systems show excellent thermal stability and good recyclability.

  8. 40 CFR 75.64 - Quarterly reports.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...

  9. 40 CFR 75.64 - Quarterly reports.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...

  10. 40 CFR 75.64 - Quarterly reports.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...

  11. 40 CFR 75.64 - Quarterly reports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...

  12. Stored grain pack factors for wheat: comparison of three methods to field measurements

    USDA-ARS?s Scientific Manuscript database

    Storing grain in bulk storage units results in grain packing from overbearing pressure, which increases grain bulk density and storage-unit capacity. This study compared pack factors of hard red winter (HRW) wheat in vertical storage bins using different methods: the existing packing model (WPACKING...

  13. ANALYTICAL EQUATIONS OF STORAGE RESERVOIR WATER QUALITY

    EPA Science Inventory

    Distribution system water quality protection is an integral aspect of public water supply management. Effective regulatory compliance requires a thorough understanding of the transport and mixing processes in storage reservoirs and their impacts on effluent water quality. This ...

  14. Something old, something new: Why models need a multi-pool representation of storage reserves

    NASA Astrophysics Data System (ADS)

    Richardson, Andrew; Carbone, Mariah

    2015-04-01

    We know surprisingly little about processes regulating the allocation of photosynthetic assimilates to growth, storage, and other metabolic functions. Storage of nonstructural carbon (NSC, principally sugars and starch) is critically important for woody plants, because these reserves enable sessile, long-lived organisms to tolerate biotic and abiotic stress, including pests, disturbance, and drought. But, critical questions about the size and turnover of these reserves remain unanswered. Labeling studies have generally shown rapid use of new (labeled) NSC and inferred fast mixing between old and new NSC, both of which suggest quick turnover of storage reserves. However, recent studies have shown that some of the reserves stored in stem and root tissue are not only a decade old, but also still available to support new tissue growth following catastrophic disturbance. We characterized the distribution of NSC in the stemwood, branches, and roots of two temperate trees, and we used the continuous label offered by the radiocarbon (14C) bomb spike to estimate the mean age of NSC in different tissues of two temperate trees. NSC in branches and outermost stemwood growth rings had the 14C signature of the current growing season. However, NSC in older above- and below-ground tissues was enriched in 14C, indicating that it was produced from older assimilates. Radial patterns of 14C in stemwood NSC showed strong mixing of NSC across the youngest growth rings, with limited "mixing in" of younger NSC to older rings. Sugars in the outermost 5 growth rings, accounting for two-thirds of the stemwood pool, had a mean age < 1 y, whereas sugars in older growth rings had a mean age > 5 y. Thus, there is not a single, well-mixed "storage pool," and indeed "young" and "old" storage compounds appear to be physically isolated from each other. We will discuss the implications of these results for improving model representation of NSC storage and consumption by forest trees. We will suggest that there are conceptual similarities between modeling NSC pools and modeling soil C pools. We will propose future directions for modeling NSCs and also identify key questions that still need to be answered with new experimental work.

  15. Predicting new multicomponent materials for hydrogen storage using first-principles calculations

    NASA Astrophysics Data System (ADS)

    Aidhy, Dilpuneet; Wolverton, Chris

    2010-03-01

    Wide research has unraveled some very promising hydrogen storage materials such as metal borohydrides, amides and alanates. However, all of these materials are limited either thermodynamically or kinetically. The recent observation of mixing in these systems (e.g., borohydride-amide mixing in Li4(BH4)(NH2)3 [1] and metal mixing in NaZn2(BH4)3) [2] has demonstrated the possibility of forming new multicomponent ordered compounds that may have desirable hydrogen storage properties. However, these multicomponent systems are largely unexplored. Here, we use density functional theory (DFT) along with Monte Carlo-based crystal structure prediction methods to search for new multicomponent hydrides. We find evidence for stable compounds in the Mg(BH4)2/Mg(NH2)2 system, which have not yet been observed. In addition, we also study a wide range of mixed metal borohydride systems, and find evidence of ordered stable structures such as Li2Na(BH4)3. 1. F. E. Pinkerton, M. S. Meyer, G. P. Meisner and M. P. Balogh, J. Phys. Chem. B 110, 7967 (2006). 2. D. Ravnsbeak, Y. Filinchuk, Y. Cerenius, H. J. Jakobsen, F. Besenbacher, J. Skibsted and T. R. Jensen, Angew. Chem. 48, 6659 (2009).

  16. Mixed noble gas effect on cut green peppers

    NASA Astrophysics Data System (ADS)

    Raymond, L. V.; Zhang, M.; Karangwa, E.; Chesereka, M. J.

    2013-01-01

    Increasing attempts at using gas which leads to hydrate formation as a preservative tool in fresh-cut fruits and vegetables have been reported. In this study, changes in some physical and biochemical properties of fresh-cut green peppers under compressed noble gas treatments were examined. Mixed argonkrypton and argon treatments were performed before cold storage at 5°C for 15 days. Mass loss and cell membrane permeability were found to be the lowest in mixed argon-krypton samples. Besides, a lower CO2 concentration and vitamin C loss were detected in gastreated samples compared to untreated samples (control). While the total phenol degradation was moderately reduced, the effect of the treatment on polyphenoloxidase activity was better at the beginning of the storage period. The minimum changes in quality observed in cut peppers resulted from both mixed and gas treatment alone.

  17. Environmental assessment, finding of no significant impact, and response to comments. Radioactive waste storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Department of Energy`s (DOE) Rocky Flats Environmental Technology Site (the Site), formerly known as the Rocky Flats Plant, has generated radioactive, hazardous, and mixed waste (waste with both radioactive and hazardous constituents) since it began operations in 1952. Such wastes were the byproducts of the Site`s original mission to produce nuclear weapons components. Since 1989, when weapons component production ceased, waste has been generated as a result of the Site`s new mission of environmental restoration and deactivation, decontamination and decommissioning (D&D) of buildings. It is anticipated that the existing onsite waste storage capacity, which meets the criteria for low-levelmore » waste (LL), low-level mixed waste (LLM), transuranic (TRU) waste, and TRU mixed waste (TRUM) would be completely filled in early 1997. At that time, either waste generating activities must cease, waste must be shipped offsite, or new waste storage capacity must be developed.« less

  18. Hanford facility dangerous waste permit application, general information portion. Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sonnichsen, J.C.

    1997-08-21

    For purposes of the Hanford facility dangerous waste permit application, the US Department of Energy`s contractors are identified as ``co-operators`` and sign in that capacity (refer to Condition I.A.2. of the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit). Any identification of these contractors as an ``operator`` elsewhere in the application is not meant to conflict with the contractors` designation as co-operators but rather is based on the contractors` contractual status with the U.S. Department of Energy, Richland Operations Office. The Dangerous Waste Portion of the initial Hanford Facility Resource Conservation and Recovery Act Permit,more » which incorporated five treatment, storage, and/or disposal units, was based on information submitted in the Hanford Facility Dangerous Waste Permit Application and in closure plan and closure/postclosure plan documentation. During 1995, the Dangerous Waste Portion was modified twice to incorporate another eight treatment, storage, and/or disposal units; during 1996, the Dangerous Waste Portion was modified once to incorporate another five treatment, storage, and/or disposal units. The permit modification process will be used at least annually to incorporate additional treatment, storage, and/or disposal units as permitting documentation for these units is finalized. The units to be included in annual modifications are specified in a schedule contained in the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit. Treatment, storage, and/or disposal units will remain in interim status until incorporated into the Permit. The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to individual operating treatment, storage, and/or disposal units for which Part B permit application documentation has been, or is anticipated to be, submitted. Documentation for treatment, storage, and/or disposal units undergoing closure, or for units that are, or are anticipated to be, dispositioned through other options, will continue to be submitted by the Permittees in accordance with the provisions of the Hanford Federal Facility Agreement and Consent Order. However, the scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the contents of the Part B permit application guidance documentation prepared by the Washington State Department of Ecology and the U.S. Environmental Protection Agency, with additional information needs defined by revisions of Washington Administrative Code 173-303 and by the Hazardous and Solid Waste Amendments. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (i.e., either operating units, units undergoing closure, or units being dispositioned through other options).« less

  19. Storage related changes of cell wall based dietary fiber components of broccoli (Brassica oleracea var. italica) stems.

    PubMed

    Schäfer, Judith; Stanojlovic, Luisa; Trierweiler, Bernhard; Bunzel, Mirko

    2017-03-01

    Storage related changes in the cell wall composition potentially affect the texture of plant-based foods and the physiological effects of cell wall based dietary fiber components. Therefore, a detailed characterization of cell wall polysaccharides and lignins from broccoli stems was performed. Freshly harvested broccoli and broccoli stored at 20°C and 1°C for different periods of time were analyzed. Effects on dietary fiber contents, polysaccharide composition, and on lignin contents/composition were much more pronounced during storage at 20°C than at 1°C. During storage, insoluble dietary fiber contents of broccoli stems increased up to 13%. Storage related polysaccharide modifications include an increase of the portions of cellulose, xylans, and homogalacturonans and a decrease of the neutral pectic side-chains arabinans and galactans. Broccoli stem lignins are generally rich in guaiacyl units. Lignins from freshly harvested broccoli stems contain slightly larger amounts of p-hydroxyphenyl units than syringyl units. Syringyl units are predominantly incorporated into the lignin polymers during storage, resulting in increased acetyl bromide soluble lignin contents. NMR-based analysis of the interunit linkage types of broccoli stem lignins revealed comparably large portions of resinol structures for a guaiacyl rich lignin. Incorporation of syringyl units into the polymers over storage predominantly occurs through β-O-4-linkages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Effect of Mixing Time and Storage Condition on Characterization of Heparinoid Admixtures with Corticosteroids.

    PubMed

    Sugiyama, Ikumi; Takahashi, Namiki; Sadzuka, Yasuyuki

    2016-01-01

    In dermatologic therapy, several external preparations formulated as ointments or creams are prescribed. And they are often admixture to improve patient compliance. In this study, we prepared admixtures of moisturizer with steroids and examined their usability and the amount of principal agent in formulations, particularly focusing on the moisturizer content. Four heparinoid semisolid formulations were selected: Hirudoid ® soft ointment 0.3% (Formulation A) and 3 generic agents [(Besoften ® oil-based cream 0.3% (Formulation B), Kuradoido ® ointment 0.3% (Formulation C), and Hepadaerm ointment 0.3% (Formulation D)], and Antebate ® ointment 0.05% (Formulation E) were used as steroids. Formulation A and B are water-in-oil emulsions, and Formulation C and D are oil-in-water emulsions. Admixtures looked like to be mixed uniformly by visual observation. In the examination of heparinoid amount, admixture A+E and B+E were mixed uniformly. On the other hand, admixture C+E was remarkable un-uniformly. It was speculated that the emulsification of formulation C was broken. The phenomenon was supported by the result of malleability. After 8 weeks storage, the heparinoid ratio in each formulation could be expressed as follows: Admixture B≥Admixture A>Admixture C=Admixture D. A suitable storage temperature was 4°C. The results of physicochemical data analysis reveal the formulations composed of water-in-oil cream, i.e., Formulation A and Formulation B, to be the optimal choices for mixing with steroid ointments. Mixing time and storage conditions may be optimized to solve pharmaceutical problems. Moreover, understanding the emulsion type and character of semisolid formulations can expand the range of formulation options.

  1. Effects of Microbial Transglutaminase on Physicochemical, Microbial and Sensorial Properties of Kefir Produced by Using Mixture Cow’s and Soymilk

    PubMed Central

    2017-01-01

    The objective of this research was to investigate the effects microbial transglutaminase (m-TGs) on the physicochemical, microbial and sensory properties of kefir produced by using mix cow and soymilk. Kefir batches were prepared using 0, 0.5, 1 and 1.5 Units m-TGs for per g of milk protein. Adding m-TGs to milk caused an increase in the pH and viscosity and caused a decrease in titratable acidity and syneresis in the kefir samples. Total bacteria, lactobacilli and streptococci counts decreased, while yeast counts increased in all the samples during storage. Alcohols and acids compounds have increased in all the samples except in the control samples, while carbonyl compounds have decreased in all the samples during storage (1-30 d). The differences in the percentage of alcohols, carbonyl compounds and acids in total volatiles on the 1st and the 30th d of storage were observed at 8.47-23.52%, 6.94-25.46% and 59.64-63.69%, respectively. The consumer evaluation of the kefir samples showed that greater levels of acceptability were found for samples which had been added 1.5 U m-TGs for per g of milk protein. PMID:28943774

  2. Effects of Microbial Transglutaminase on Physicochemical, Microbial and Sensorial Properties of Kefir Produced by Using Mixture Cow's and Soymilk.

    PubMed

    Temiz, Hasan; Dağyıldız, Kübra

    2017-01-01

    The objective of this research was to investigate the effects microbial transglutaminase (m-TGs) on the physicochemical, microbial and sensory properties of kefir produced by using mix cow and soymilk. Kefir batches were prepared using 0, 0.5, 1 and 1.5 Units m-TGs for per g of milk protein. Adding m-TGs to milk caused an increase in the pH and viscosity and caused a decrease in titratable acidity and syneresis in the kefir samples. Total bacteria, lactobacilli and streptococci counts decreased, while yeast counts increased in all the samples during storage. Alcohols and acids compounds have increased in all the samples except in the control samples, while carbonyl compounds have decreased in all the samples during storage (1-30 d). The differences in the percentage of alcohols, carbonyl compounds and acids in total volatiles on the 1st and the 30th d of storage were observed at 8.47-23.52%, 6.94-25.46% and 59.64-63.69%, respectively. The consumer evaluation of the kefir samples showed that greater levels of acceptability were found for samples which had been added 1.5 U m-TGs for per g of milk protein.

  3. Geologic framework for the national assessment of carbon dioxide storage resources: Powder River Basin, Wyoming, Montana, South Dakota, and Nebraska: Chapter B in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Craddock, William H.; Drake II, Ronald M.; Mars, John L.; Merrill, Matthew D.; Warwick, Peter D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Cahan, Steven A.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.

    2012-01-01

    This report presents ten storage assessment units (SAUs) within the Powder River Basin of Wyoming, Montana, South Dakota, and Nebraska. The Powder River Basin contains a thick succession of sedimentary rocks that accumulated steadily throughout much of the Phanerozoic, and at least three stratigraphic packages contain strata that are suitable for CO2 storage. Pennsylvanian through Triassic siliciclastic strata contain two potential storage units: the Pennsylvanian and Permian Tensleep Sandstone and Minnelusa Formation, and the Triassic Crow Mountain Sandstone. Jurassic siliciclastic strata contain one potential storage unit: the lower part of the Sundance Formation. Cretaceous siliciclastic strata contain seven potential storage units: (1) the Fall River and Lakota Formations, (2) the Muddy Sandstone, (3) the Frontier Sandstone and Turner Sandy Member of the Carlile Shale, (4) the Sussex and Shannon Sandstone Members of Cody Shale, and (5) the Parkman, (6) Teapot, and (7) Teckla Sandstone Members of the Mesaverde Formation. For each SAU, we discuss the areal distribution of suitable CO2 reservoir rock. We also characterize the overlying sealing unit and describe the geologic characteristics that influence the potential CO2 storage volume and reservoir performance. These characteristics include reservoir depth, gross thickness, net thickness, porosity, permeability, and groundwater salinity. Case-by-case strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are presented. Although assessment results are not contained in this report, the geologic information included herein will be employed to calculate the potential storage space in the various SAUs.

  4. An optimization model for carbon capture & storage/utilization vs. carbon trading: A case study of fossil-fired power plants in Turkey.

    PubMed

    Ağralı, Semra; Üçtuğ, Fehmi Görkem; Türkmen, Burçin Atılgan

    2018-06-01

    We consider fossil-fired power plants that operate in an environment where a cap and trade system is in operation. These plants need to choose between carbon capture and storage (CCS), carbon capture and utilization (CCU), or carbon trading in order to obey emissions limits enforced by the government. We develop a mixed-integer programming model that decides on the capacities of carbon capture units, if it is optimal to install them, the transportation network that needs to be built for transporting the carbon captured, and the locations of storage sites, if they are decided to be built. Main restrictions on the system are the minimum and maximum capacities of the different parts of the pipeline network, the amount of carbon that can be sold to companies for utilization, and the capacities on the storage sites. Under these restrictions, the model aims to minimize the net present value of the sum of the costs associated with installation and operation of the carbon capture unit and the transportation of carbon, the storage cost in case of CCS, the cost (or revenue) that results from the emissions trading system, and finally the negative revenue of selling the carbon to other entities for utilization. We implement the model on General Algebraic Modeling System (GAMS) by using data associated with two coal-fired power plants located in different regions of Turkey. We choose enhanced oil recovery (EOR) as the process in which carbon would be utilized. The results show that CCU is preferable to CCS as long as there is sufficient demand in the EOR market. The distance between the location of emission and location of utilization/storage, and the capacity limits on the pipes are an important factor in deciding between carbon capture and carbon trading. At carbon prices over $15/ton, carbon capture becomes preferable to carbon trading. These results show that as far as Turkey is concerned, CCU should be prioritized as a means of reducing nation-wide carbon emissions in an environmentally and economically rewarding manner. The model developed in this study is generic, and it can be applied to any industry at any location, as long as the required inputs are available. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer.

    PubMed

    Hatamleh, Muhanad M; Polyzois, Gregory L; Silikas, Nick; Watts, David C

    2011-08-01

    The purpose of this study was to investigate the effect of extraoral human and environmental conditions on the mechanical properties (tensile strength and modulus, elongation, tear strength hardness) of maxillofacial silicone elastomer. Specimens were fabricated using TechSil-S25 silicone elastomer (Technovent Ltd, Leeds, UK). Eight groups were prepared (21 specimens in each group; eight tensile, eight tear, five hardness) and conditioned differently as follows (groups 1 through 8): Dry storage for 24 hours; dry storage in dark for 6 months; storage in simulated sebum solution for 6 months; storage in simulated acidic perspiration for 6 months; accelerated artificial daylight aging under controlled moisture for 360 hours; outdoor weathering for 6 months; storage in antimicrobial silicone-cleaning solution for 30 hours; and mixed conditioning of sebum storage and light aging for 360 hours. The conditioning period selected simulated a prosthesis being in service for up to 12 months. Tensile and tear test specimens were fabricated and tested according to the International Standards Organization (ISO) standards no. 37 and 34, respectively. Shore A hardness test specimens were fabricated and tested according to the American Standards for Testing and Materials (ASTM) D 2240. Data were analyzed with one-way ANOVA, Bonferroni, and Dunnett's T3 post hoc tests (p < 0.05). Weibull analysis was also used for tensile strength and tear strength. Statistically significant differences were evident among all properties tested. Mixed conditioning of simulated sebum storage under accelerated artificial daylight aging significantly degraded mechanical properties of the silicone (p < 0.05). Mechanical properties of maxillofacial elastomers are adversely affected by human and environmental factors. Mixed aging of storage in simulated sebum under accelerated daylight aging was the most degrading regime. Accelerated aging of silicone specimens in simulated sebum under artificial daylight for 12 months of simulated clinical service greatly affected functional properties of silicone elastomer; however, in real practice, the effect is modest, since sebum concentration is lower, and daylight is less concentrated. © 2011 by The American College of Prosthodontists.

  6. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Wesley J.; Frew, Bethany A.; Gagnon, Pieter J.

    In this report we summarize the implications, impacts, and deployment potential of reaching the SunShot 2030 targets for the electricity system in the contiguous United States. We model 25 scenarios of the U.S. power sector using the Regional Energy Deployment Systems (ReEDS) and Distributed Generation (dGen) capacity expansion models. The scenarios cover a wide range of sensitivities to capture future uncertainties relating to fuel prices, retirements, renewable energy capital costs, and load growth. We give special attention to the potential for storage costs to also rapidly decline due to its large synergies with low-cost solar. The ReEDS and dGen modelsmore » project utility- and distributed-scale power sector evolution, respectively, for the United States. Both models have been designed with special emphasis on capturing the unique traits of renewable energy, including variability and grid integration requirements. Across the suite of scenarios modeled, we find that reaching the SunShot 2030 target has the potential to lead to significant capacity additions of PV in the United States. By 2050, PV penetration levels are projected to reach 28-46 percent of total generation. If storage also sees significant reductions in cost, then the 2050 solar penetration levels could reach 41-64 percent. PV deployment is projected to occur in all of the lower 48 states, though the specific deployment level is scenario dependent. The growth in PV is projected to be dominated by utility-scale systems, but the actual mix between utility and distributed systems could ultimately vary depending on how policies, system costs, and rate structures evolve.« less

  7. The effect of pre-storage cooling on 2,3-DPG levels in red cells stored in SAG-M.

    PubMed

    Llohn, Abid Hussain; Vetlesen, Annette; Fagerhol, Magne Kristoffer; Kjeldsen-Kragh, Jens

    2005-10-01

    The concentration of red cell 2,3-DPG (2,3-diphosphoglycerate) rapidly decreases during storage. A favourable effect on red cell 2,3-DPG has been demonstrated by rapid cooling of whole blood prior to storage. In our study we have investigated how different methods of cooling whole blood immediately after donation effect 2,3-DPG levels during storage. Thirty-six whole blood units (in 6 groups) of 450 ml were collected in 63 ml CPD. SAG-M was used as preservative solution for red cell concentrates (RCC). The units in one group were cooled down at ambient temperature, while units in the other groups were cooled down rapidly by different ways immediately after bleeding. Samples from the whole blood units were collected at various days during storage for 2,3-DPG measurements. The decline in 2,3-DPG during the first two weeks of storage was significantly slower in the groups which were cooled down rapidly to 17-18 degrees C within 1h after bleeding (all p

  8. Film processing investigation. [improved chemical mixing system

    NASA Technical Reports Server (NTRS)

    Kelly, J. L.

    1972-01-01

    The present operational chemical mixing system for the Photographic Technology Division is evaluated, and the limitations are defined in terms of meeting the present and programmed chemical supply and delivery requirements. A major redesign of the entire chemical mixing, storage, analysis, and supply system is recommended. Other requirements for immediate and future implementations are presented.

  9. Freestanding two-dimensional Ni(OH)2 thin sheets assembled by 3D nanoflake array as basic building units for supercapacitor electrode materials.

    PubMed

    Song, Dianmei; Zhu, Jikui; Xuan, Liying; Zhao, Chenglan; Xie, Li; Chen, Lingyun

    2018-01-01

    Freestanding two dimensional (2D) porous nanostructures have great potential in electrical energy storage. In the present work, we reported the first synthesis of two-dimensional (2D) β-Ni(OH) 2 thin sheets (CQU-Chen-Ni-O-H-1) assembled by 3D nanoflake array as basic building units under acid condition by direct hydrothermal decomposition of the mixed solution of nickel nitrate (Ni(NO 3 ) 2 ) and acetic acid (CH 3 COOH, AA). The unique 3D nanoflake array assembled mesoporous 2D structures endow the thin sheets with a high specific capacitance of 1.78Fcm -2 (1747.5Fg -1 ) at the current density of 1.02mAcm -2 and good rate capability of 67.4% retain from 1.02 to 10.2mAcm -2 . The corresponding assembled asymmetric supercapacitor (ASC) achieves (CQU-Chen-Ni-O-H-1//active carbon (AC)) a high voltage of 1.8V and an energy density of 23.45Whkg -1 with a maximum power density of 9kWkg -1 , as well as cycability with 93.6% capacitance retention after 10,000 cycles. These results show the mesoporous thin sheets have great potential for SCs and other energy storage devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Quality changes of chicken meat jerky with different sweeteners during storage.

    PubMed

    Wongwiwat, Pirinya; Wattanachant, Saowakon

    2015-12-01

    Chicken meat jerky with high sugar content is popular intermediate-moisture meat product in Asia. Different types of sugar, sucrose and mixed sugar (sucrose: fructose: sorbitol 70: 15: 15), were evaluated to improve the quality of product. Quality changes of chicken meat jerky stored in vacuum and aerobic (33 and 75 %relative humidity, %RH) conditions were studied for suitable condition to extend shelf-life of product. The samples were determined the physical and chemical characteristics, as well as sensory evaluation during storage at room temperature. The moisture content and water activity (aw) of samples stored in 33 %RH conditions was continuously diminished during storage that related to harder texture and unacceptable quality in sensory evaluation. All samples stored in vacuum and 75 %RH condition demonstrated the lower shear force value than that stored in 33%RH condition (p < 0.05). Samples stored in vacuum condition had the lowest lipid oxidation (p < 0.05.) which corresponding to the highest scores in less rancidity and overall acceptance attributes. All samples stored in vacuum condition also had the highest acceptability in all sensory attributes (taste, rancidity, color and overall acceptance) followed by 75 %RH storage condition (p < 0.05). Samples prepared with mixed sugar could improve color and retard rancidity in chicken jerky meat product. Sample prepared with mixed sugar kept in vacuum condition had the lowest lipid oxidation and highest sensory score in overall acceptance attributes along the extended storage.

  11. MODELING DISINFECTANT RESIDUALS IN DRINKING-WATER STORAGE TANKS

    EPA Science Inventory

    The factors leading to the loss of disinfectant residual in well-mixed drinking-water storage tanks are studied. Equations relating disinfectant residual to the disinfectant's reation rate, the tank volume, and the fill and drain rates are presented. An analytical solution for ...

  12. Effects of Juice Matrix and Pasteurization on Stability of Black Currant Anthocyanins during Storage.

    PubMed

    Dobson, Gary; McDougall, Gordon J; Stewart, Derek; Cubero, Miguel Ángel; Karjalainen, Reijo O

    2017-01-01

    The effects of juice matrix and pasteurization on the stability of total phenols and especially total and individual anthocyanins were examined in black currant (BC) juice and mixtures with apple, persimmon, and peach juices at 4 °C and 20 °C. Total phenol content decreased in all juices at both temperatures but there was a trend to lower levels in unpasteurized over pasteurized juices. Differences in the decline of total anthocyanins between pasteurized and unpasteurized juices varied according to the juice type and the storage temperature. At 4 °C storage, anthocyanins declined in all juices according to pseudo 1st-order kinetics and there were only small differences in the rates between pasteurized and unpasteurized juices. However, at 20 °C, although pasteurized and unpasteurized BC juices and pasteurized mixed juices followed pseudo 1st-order kinetics, there was a different pattern in unpasteurized mixed juices; a rapid initial decline was followed by a slowing down. The effect of the added juice on anthocyanin decline was also different at either temperature. At 4 °C, the anthocyanins decreased faster in mixed juices than BC juice alone, but at 20 °C, at least in pasteurized mixed juices, the decline was similar or even slower than in BC juice; there were only small differences among the 3 mixed juices. At 20 °C, in pasteurized and unpasteurized BC juices, the rate of decrease was essentially the same for all 4 individual anthocyanins but in the mixed juices the 2 glucosides decreased significantly faster than the 2 rutinosides. © 2016 Institute of Food Technologists®.

  13. Environmental Control Unit with Integral Thermal Storage

    DTIC Science & Technology

    2014-06-12

    integrated PCM Heat Exchanger (PHX) to provide thermal energy storage . By storing thermal energy during the hottest part of the day and rejecting this stored...Environmental Control Unit (ECU) that uses an integrated PCM Heat Exchanger (PHX) to provide thermal energy storage . To aid in the development of the PHX...Thermal Storage 5a. CONTRACT NUMBER W911QX-14-C-0014 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Michael C. Ellis Ryan McDevitt 5d

  14. Effect of sand and method of mixing on molten salt properties for an open direct absorption solar receiver/storage system

    NASA Astrophysics Data System (ADS)

    AlQaydi, Muna; Delclos, Thomas; AlMheiri, Saif; Calvet, Nicolas

    2017-06-01

    The concept of CSPonD Demo project is based on a single and open molten salt tank as a thermal solar receiver and storage unit. Therefore, the effect of external environment such as sand and air on the thermophysical properties of nitrate salt (60 wt. % sodium nitrate, 40 wt. % potassium nitrate) has been investigated in this work. Differential Scanning Calorimeter (DSC) was used to determine the melting, solidification temperatures while the thermal stability and mass loss measurements were carried on Thermal Gravimetric Analysis (TGA). Measurements under nitrogen indicate that the adding 2% (w/w) sand has negative impact by increasing the solidification temperature, mass loss percentage and decreasing the stability limit. While the melting temperature was not affected by the sand and by the preparation method. On the other hand, measurement under air showed an increase of the stability limit and decrease of the mass loss percentage. Furthermore, the measurements for the mass loss under air did not reach a stable value, which required further investigation.

  15. Metal-free supercapacitor with aqueous electrolyte and low-cost carbon materials

    NASA Astrophysics Data System (ADS)

    Blomquist, Nicklas; Wells, Thomas; Andres, Britta; Bäckström, Joakim; Forsberg, Sven; Olin, Håkan

    2017-01-01

    Electric double-layer capacitors (EDLCs) or supercapacitors (SCs) are fast energy storage devices with high pulse efficiency and superior cyclability, which makes them useful in various applications including electronics, vehicles and grids. Aqueous SCs are considered to be more environmentally friendly than those based on organic electrolytes. Because of the corrosive nature of the aqueous environment, however, expensive electrochemically stable materials are needed for the current collectors and electrodes in aqueous SCs. This results in high costs for a given energy-storage capacity. To address this, we developed a novel low-cost aqueous SC using graphite foil as the current collector and a mix of graphene, nanographite, simple water-purification carbons and nanocellulose as electrodes. The electrodes were coated directly onto the graphite foil by using casting frames and the SCs were assembled in a pouch cell design. With this approach, we achieved a material cost reduction of greater than 90% while maintaining approximately one-half of the specific capacitance of a commercial unit, thus demonstrating that the proposed SC can be an environmentally friendly, low-cost alternative to conventional SCs.

  16. Optimal Operation System of the Integrated District Heating System with Multiple Regional Branches

    NASA Astrophysics Data System (ADS)

    Kim, Ui Sik; Park, Tae Chang; Kim, Lae-Hyun; Yeo, Yeong Koo

    This paper presents an optimal production and distribution management for structural and operational optimization of the integrated district heating system (DHS) with multiple regional branches. A DHS consists of energy suppliers and consumers, district heating pipelines network and heat storage facilities in the covered region. In the optimal management system, production of heat and electric power, regional heat demand, electric power bidding and sales, transport and storage of heat at each regional DHS are taken into account. The optimal management system is formulated as a mixed integer linear programming (MILP) where the objectives is to minimize the overall cost of the integrated DHS while satisfying the operation constraints of heat units and networks as well as fulfilling heating demands from consumers. Piecewise linear formulation of the production cost function and stairwise formulation of the start-up cost function are used to compute nonlinear cost function approximately. Evaluation of the total overall cost is based on weekly operations at each district heat branches. Numerical simulations show the increase of energy efficiency due to the introduction of the present optimal management system.

  17. Mixed Integer Programming Model and Incremental Optimization for Delivery and Storage Planning Using Truck Terminals

    NASA Astrophysics Data System (ADS)

    Sakakibara, Kazutoshi; Tian, Yajie; Nishikawa, Ikuko

    We discuss the planning of transportation by trucks over a multi-day period. Each truck collects loads from suppliers and delivers them to assembly plants or a truck terminal. By exploiting the truck terminal as a temporal storage, we aim to increase the load ratio of each truck and to minimize the lead time for transportation. In this paper, we show a mixed integer programming model which represents each product explicitly, and discuss the decomposition of the problem into a problem of delivery and storage, and a problem of vehicle routing. Based on this model, we propose a relax-and-fix type heuristic in which decision variables are fixed one by one by mathematical programming techniques such as branch-and-bound methods.

  18. Modernisation Issues of Diesel-Electric Shunting Locomotive Power Units

    NASA Astrophysics Data System (ADS)

    Hoimoja, Hardi; Jalakas, Tanel; Rosin, Argo; Rassylkin, Anton

    2010-01-01

    The research concentrates on the modernisation issues of inefficient diesel-electric shunting locomotives, produced in the former Soviet Union. The existing diesel-generator unit, serving as an onboard power plant can be replaced by hybridised units, with an energy storage unit acting as a peaking power source for dynamic modes. By integrating an energy storage unit into the power plant, the locomotive traction drive becomes hybridised, consuming less fuel during transients and idling.

  19. Numerical modeling of gas mixing and bio-chemical transformations during underground hydrogen storage within the project H2STORE

    NASA Astrophysics Data System (ADS)

    Hagemann, B.; Feldmann, F.; Panfilov, M.; Ganzer, L.

    2015-12-01

    The change from fossil to renewable energy sources is demanding an increasing amount of storage capacities for electrical energy. A promising technological solution is the storage of hydrogen in the subsurface. Hydrogen can be produced by electrolysis using excessive electrical energy and subsequently converted back into electricity by fuel cells or engine generators. The development of this technology starts with adding small amounts of hydrogen to the high pressure natural gas grid and continues with the creation of pure underground hydrogen storages. The feasibility of hydrogen storage in depleted gas reservoirs is investigated in the lighthouse project H2STORE financed by the German Ministry for Education and Research. The joint research project has project members from the University of Jena, the Clausthal University of Technology, the GFZ Potsdam and the French National Center for Scientic Research in Nancy. The six sub projects are based on laboratory experiments, numerical simulations and analytical work which cover the investigation of mineralogical, geochemical, physio-chemical, sedimentological, microbiological and gas mixing processes in reservoir and cap rocks. The focus in this presentation is on the numerical modeling of underground hydrogen storage. A mathematical model was developed which describes the involved coupled hydrodynamic and microbiological effects. Thereby, the bio-chemical reaction rates depend on the kinetics of microbial growth which is induced by the injection of hydrogen. The model has been numerically implemented on the basis of the open source code DuMuX. A field case study based on a real German gas reservoir was performed to investigate the mixing of hydrogen with residual gases and to discover the consequences of bio-chemical reactions.

  20. Bypass apparatus and method for series connected energy storage devices

    DOEpatents

    Rouillard, Jean; Comte, Christophe; Daigle, Dominik

    2000-01-01

    A bypass apparatus and method for series connected energy storage devices. Each of the energy storage devices coupled to a common series connection has an associated bypass unit connected thereto in parallel. A current bypass unit includes a sensor which is coupled in parallel with an associated energy storage device or cell and senses an energy parameter indicative of an energy state of the cell, such as cell voltage. A bypass switch is coupled in parallel with the energy storage cell and operable between a non-activated state and an activated state. The bypass switch, when in the non-activated state, is substantially non-conductive with respect to current passing through the energy storage cell and, when in the activated state, provides a bypass current path for passing current to the series connection so as to bypass the associated cell. A controller controls activation of the bypass switch in response to the voltage of the cell deviating from a pre-established voltage setpoint. The controller may be included within the bypass unit or be disposed on a control platform external to the bypass unit. The bypass switch may, when activated, establish a permanent or a temporary bypass current path.

  1. Incompletely Mixed Surface Transient Storage Zones at River Restoration Structures: Modeling Implications

    NASA Astrophysics Data System (ADS)

    Endreny, T. A.; Robinson, J.

    2012-12-01

    River restoration structures, also known as river steering deflectors, are designed to reduce bank shear stress by generating wake zones between the bank and the constricted conveyance region. There is interest in characterizing the surface transient storage (STS) and associated biogeochemical processing in the STS zones around these structures to quantify the ecosystem benefits of river restoration. This research explored how the hydraulics around river restoration structures prohibits application of transient storage models designed for homogenous, completely mixed STS zones. We used slug and constant rate injections of a conservative tracer in a 3rd order river in Onondaga County, NY over the course of five experiments at varying flow regimes. Recovered breakthrough curves spanned a transect including the main channel and wake zone at a j-hook restoration structure. We noted divergent patterns of peak solute concentration and times within the wake zone regardless of transect location within the structure. Analysis reveals an inhomogeneous STS zone which is frequently still loading tracer after the main channel has peaked. The breakthrough curve loading patterns at the restoration structure violated the assumptions of simplified "random walk" 2 zone transient storage models which seek to identify representative STS zones and zone locations. Use of structure-scale Weiner filter based multi-rate mass transfer models to characterize STS zones residence times are similarly dependent on a representative zone location. Each 2 zone model assumes 1 zone is a completely mixed STS zone and the other a completely mixed main channel. Our research reveals limits to simple application of the recently developed 2 zone models, and raises important questions about the measurement scale necessary to identify critical STS properties at restoration sites. An explanation for the incompletely mixed STS zone may be the distinct hydraulics at restoration sites, including a constrained high velocity conveyance region closely abutting a wake zone that receives periodic disruption from the upstream structure shearing vortices.igure 1. River restoration j-hook with blue dye revealing main channel and edge of wake zone with multiple surface transient storage zones.

  2. 21. Detail of typical refrigeration unit in the southwest corner ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Detail of typical refrigeration unit in the southwest corner of the fruit and vegetable storage room - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  3. U.S. DOE methodology for the development of geologic storage potential for carbon dioxide at the national and regional scale

    USGS Publications Warehouse

    Goodman, Angela; Hakala, J. Alexandra; Bromhal, Grant; Deel, Dawn; Rodosta, Traci; Frailey, Scott; Small, Michael; Allen, Doug; Romanov, Vyacheslav; Fazio, Jim; Huerta, Nicolas; McIntyre, Dustin; Kutchko, Barbara; Guthrie, George

    2011-01-01

    A detailed description of the United States Department of Energy (US-DOE) methodology for estimating CO2 storage potential for oil and gas reservoirs, saline formations, and unmineable coal seams is provided. The oil and gas reservoirs are assessed at the field level, while saline formations and unmineable coal seams are assessed at the basin level. The US-DOE methodology is intended for external users such as the Regional Carbon Sequestration Partnerships (RCSPs), future project developers, and governmental entities to produce high-level CO2 resource assessments of potential CO2 storage reservoirs in the United States and Canada at the regional and national scale; however, this methodology is general enough that it could be applied globally. The purpose of the US-DOE CO2 storage methodology, definitions of storage terms, and a CO2 storage classification are provided. Methodology for CO2 storage resource estimate calculation is outlined. The Log Odds Method when applied with Monte Carlo Sampling is presented in detail for estimation of CO2 storage efficiency needed for CO2 storage resource estimates at the regional and national scale. CO2 storage potential reported in the US-DOE's assessment are intended to be distributed online by a geographic information system in NatCarb and made available as hard-copy in the Carbon Sequestration Atlas of the United States and Canada. US-DOE's methodology will be continuously refined, incorporating results of the Development Phase projects conducted by the RCSPs from 2008 to 2018. Estimates will be formally updated every two years in subsequent versions of the Carbon Sequestration Atlas of the United States and Canada.

  4. Baseline extracellular potassium level as an indicator of the rate of increase of the same on further storage in CPDA-1 whole blood units: a potential approach to complement FIFO system for prioritisation of blood bags for release from blood-banks.

    PubMed

    Baliarsingh, S; Jaiswal, M

    2014-02-01

    Potassium levels in stored blood bags increases as they age. Hyperkalemia in transfused blood has undesirable cardiac effects. Within a 19-month period, baseline and weekly samples from 15 CPDA-1 whole blood bags were collected till 28 days of storage and analysed for potassium, sodium, uric acid, albumin and whole blood haemoglobin. One unit increase in baseline (0 day) potassium in extracellular fluid of blood units was associated with the following increases in potassium levels on later days of storage: around two unit increase at 1 week (r2 = 0·50, P < 0·01) of storage; four units increase at 2 weeks (r2 = 0·64, P < 0·001) and 3 weeks (r2 = 0·51, P < 0·01) of storage; six units at 4 weeks (r2 = 0·53, P < 0·01) of storage. Baseline whole blood haemoglobin showed a moderate association with baseline potassium (r2 = 0·36, P < 0·05) and 2-week potassium (r2 = 0·35, P < 0·05) values. For CPDA-1 blood bags (i) low baseline potassium blood bags might be preferred for transfusion in cases demanding a low potassium load and (ii) coordinating the ‘first-in-first-out’ (FIFO) policy with ‘early release of blood-bags with high initial potassium’ might be helpful in improving the release of suitable blood units from blood-banks.

  5. Case study - Dynamic pressure-limited capacity and costs of CO2 storage in the Mount Simon sandstone

    USGS Publications Warehouse

    Anderson, Steven T.; Jahediesfanjani, Hossein

    2017-01-01

    Widespread deployment of carbon capture and storage (CCS) is likely necessary to be able to satisfy baseload electricity demand, to maintain diversity in the energy mix, and to achieve climate and other objectives at the lowest cost. If all of the carbon dioxide (CO2) emissions from stationary sources (such as fossil-fuel burning power plants, and other industrial plants) in the United States needed to be captured and stored, it could be possible to store only a small fraction of this CO2 in oil and natural gas reservoirs, including as a result of CO2 utilization for enhanced oil recovery. The vast majority would have to be stored in saline-filled reservoirs (Dahowski et al., 2005). Given a lack of long-term commercial-scale CCS projects, there is considerable uncertainty in the risks, dynamic capacity, and their cost implications for geologic storage of CO2. Pressure buildup in the storage reservoir is expected to be a primary source of risk associated with CO2 storage, and could severely limit CO2 injection rates (dynamic storage capacities). Most cost estimates for commercial-scale deployment of CCS estimate CO2 storage costs under assumed availability of a theoretical capacity to store tens, hundreds, or even thousands of gigatons of CO2, without considering geologic heterogeneities, pressure limitations, or the time dimension. This could lead to underestimation of the costs of CO2 storage (Anderson, 2017). This paper considers the impacts of pressure limitations and geologic heterogeneity on the dynamic CO2 storage capacity and storage (injection) costs. In the U.S. Geological Survey (USGS)’s National Assessment of Geologic CO2 Storage Resources (USGS, 2013), the mean estimate of the theoretical storage capacity in the Mount Simon Sandstone was about 94 billion metric tons of CO2. However, our results suggest that the pressure-limited capacity after 50 years of injection could be only about 4% of the theoretical geologic storage capacity in this formation. Because this is far less than emissions of CO2 from stationary sources in the region around the Mount Simon Sandstone, the costs to accommodate the potential annual demand for CO2 storage in this formation could be significantly greater than current estimates. Our results could have implications for how long and to what extent decision makers can expect to be able to deploy CCS before transitioning to other low- or zero-carbon energy technologies.

  6. Integrated strategic and tactical biomass-biofuel supply chain optimization.

    PubMed

    Lin, Tao; Rodríguez, Luis F; Shastri, Yogendra N; Hansen, Alan C; Ting, K C

    2014-03-01

    To ensure effective biomass feedstock provision for large-scale biofuel production, an integrated biomass supply chain optimization model was developed to minimize annual biomass-ethanol production costs by optimizing both strategic and tactical planning decisions simultaneously. The mixed integer linear programming model optimizes the activities range from biomass harvesting, packing, in-field transportation, stacking, transportation, preprocessing, and storage, to ethanol production and distribution. The numbers, locations, and capacities of facilities as well as biomass and ethanol distribution patterns are key strategic decisions; while biomass production, delivery, and operating schedules and inventory monitoring are key tactical decisions. The model was implemented to study Miscanthus-ethanol supply chain in Illinois. The base case results showed unit Miscanthus-ethanol production costs were $0.72L(-1) of ethanol. Biorefinery related costs accounts for 62% of the total costs, followed by biomass procurement costs. Sensitivity analysis showed that a 50% reduction in biomass yield would increase unit production costs by 11%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Underground storage of imported water in the San Gorgonio Pass area, southern California

    USGS Publications Warehouse

    Bloyd, Richard M.

    1971-01-01

    The San Gorgonio Pass ground-water basin is divided into the Beaumont, Banning, Cabazon, San Timoteo, South Beaumont, Banning Bench, and Singleton storage units. The Beaumont storage unit, centrally located in the agency area, is the largest in volume of the storage units. Estimated long-term average annual precipitation in the San Gorgonio Pass Water Agency drainage area is 332,000 acre-feet, and estimated average annual recoverable water is 24,000 acre-feet, less than 10 percent of the total precipitation. Estimated average annual surface outflow is 1,700 acre-feet, and estimated average annual ground-water recharge is 22,000 acre-feet. Projecting tack to probable steady-state conditions, of the 22.000 acre-feet of recharge, 16,003 acre-feet per year became subsurface outflow into Coachella Valley, 6,000 acre-feet into the Redlands area, and 220 acre-feet into Potrero Canyon. After extensive development, estimated subsurface outflow from the area in 1967 was 6,000 acre-feet into the Redlands area, 220 acre-feet into Potrero Canyon, and 800 acre-feet into the fault systems south of the Banning storage unit, unwatered during construction of a tunnel. Subsurface outflow into Coachella Valley in 1967 is probably less than 50 percent of the steady-state flow. An anticipated 17,000 .acre-feet of water per year will be imported by 1980. Information developed in this study indicates it is technically feasible to store imported water in the eastern part of the Beaumont storage unit without causing waterlogging in the storage area and without losing any significant quantity of stored water.

  8. Optimal mix of renewable power generation in the MENA region as a basis for an efficient electricity supply to europe

    NASA Astrophysics Data System (ADS)

    Alhamwi, Alaa; Kleinhans, David; Weitemeyer, Stefan; Vogt, Thomas

    2014-12-01

    Renewable Energy sources are gaining importance in the Middle East and North Africa (MENA) region. The purpose of this study is to quantify the optimal mix of renewable power generation in the MENA region, taking Morocco as a case study. Based on hourly meteorological data and load data, a 100% solar-plus-wind only scenario for Morocco is investigated. For the optimal mix analyses, a mismatch energy modelling approach is adopted with the objective to minimise the required storage capacities. For a hypothetical Moroccan energy supply system which is entirely based on renewable energy sources, our results show that the minimum storage capacity is achieved at a share of 63% solar and 37% wind power generations.

  9. Assessment of changes in plasma hemoglobin and potassium levels in red cell units during processing and storage.

    PubMed

    Saini, Nishant; Basu, Sabita; Kaur, Ravneet; Kaur, Jasbinder

    2015-06-01

    Red cell units undergo changes during storage and processing. The study was planned to assess plasma potassium, plasma hemoglobin, percentage hemolysis during storage and to determine the effects of outdoor blood collection and processing on those parameters. Blood collection in three types of blood storage bags was done - single CPDA bag (40 outdoor and 40 in-house collection), triple CPD + SAGM bag (40 in-house collection) and quadruple CPD + SAGM bag with integral leukoreduction filter (40 in-house collection). All bags were sampled on day 0 (day of collection), day 1 (after processing), day 7, day 14 and day 28 for measurement of percentage hemolysis and potassium levels in the plasma of bag contents. There was significant increase in percentage hemolysis, plasma hemoglobin and plasma potassium level in all the groups during storage (p < 0.001). No significant difference was found between any parameter analyzed for outdoor and in-house collected single CPDA red cell units. There was significant lower percentage hemolysis (p < 0.001) and potassium (day 7 to day 14 - p < 0.05 and day 14 to day 28 - p < 0.001) in red cell units from day 7 onward until day 28 of storage in the leukoreduced quadruple bag as compared to the triple bag. The in-house single CPDA red cell units showed significantly more hemolysis (p < 0.001) as compared to the triple bags with SAGM additive solution after 28 days of storage. There is gradual increase in plasma hemoglobin and plasma potassium levels during the storage of red blood cells. Blood collection can be safely undertaken in outdoor blood donation camps even in hot summer months in monitored blood transport boxes. SAGM additive solution decreases the red cell hemolysis and allows extended storage of red cells. Prestorage leukoreduction decreases the red cell hemolysis and improves the quality of blood. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. European transition to a low carbon electricity system using a mix of variable renewable energies: carbon saving trajectories as functions of production and storage capacity.

    NASA Astrophysics Data System (ADS)

    Francois, Baptiste; Creutin, Jean-Dominique

    2016-04-01

    Today, most of the produced energy is generated from fossil energy sources (i.e. coal, petroleum). As a result, the energy sector is still the main source of greenhouse gas in the atmosphere. For limiting greenhouse gas emission, a transition from fossil to renewable energy is required, increasing gradually the fraction energy coming from variable renewable energy (i.e. solar power, wind power and run-of-the river hydropower, hereafter denoted as VRE). VRE penetration, i.e. the percentage of demand satisfied by variable renewables assuming no storage capacity, is hampered by their variable and un-controllable features. Many studies show that combining different VRE over space smoothes their variability and increases their global penetration by a better match of demand fluctuations. When the demand is not fully supplied by the VRE generation, backup generation is required from stored energy (mostly from dams) or fossil sources, the latter being associated with high greenhouse gas emission. Thus the VRE penetration is a direct indicator of carbon savings and basically depends on the VRE installed capacity, its mix features, and on the installed storage capacity. In this study we analyze the European transition to a low carbon electricity system. Over a selection of representative regions we analyze carbon saving trajectories as functions of VRE production and storage capacities for different scenarios mixing one to three VRE with non-renewables. We show substantial differences between trajectories when the mix of sources is far from the local optimums, when the storage capacity evolves. We bring new elements of reflection about the effect of transport grid features from local independent systems to a European "copper plate". This work is part of the FP7 project COMPLEX (Knowledge based climate mitigation systems for a low carbon economy; Project FP7-ENV-2012 number: 308601; http://www.complex.ac.uk/).

  11. USING COMPUTER MODELS TO DETERMINE THE EFFECT OF STORAGE ON WATER QUALITY

    EPA Science Inventory

    Studies have indicated that water quality is degraded as a result of long residence times in storage tanks, highlighting the importance of tank design, location, and operation. Computer models, developed to explain some of the mixing and distrribution issues associated with tank...

  12. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    NASA Technical Reports Server (NTRS)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  13. Development of criteria for the use of asphalt-rubber as a Stress-Absorbing Membrane Interlayer (SAMI)

    NASA Astrophysics Data System (ADS)

    Newcomb, D. E.; McKeen, R. G.

    1983-12-01

    This report documents over 2 years of research efforts to characterize asphalt-rubber mixtures to be used in Stress-Absorbing Membrane Interlayers (SAMI). The purpose of these SAMIs is to retard or prevent reflection cracking in asphalt-concrete overlays. Several laboratory experiments and one field trial were conducted to define significant test methods and parameters for incorporation into construction design and specification documents. Test methods used in this study included a modified softening point test, force-ductility, and Schweyer viscosity. Variables investigated included (1) Laboratory-mixing temperature; (2) Rubber type; (3) Laboratory storage time; (4) Laboratory storage condition; (5) Laboratory batch replication; (6) Laboratory mixing time; (7) Field mixing time; (8) Laboratory test temperature; (9) Force-Ductility elongation rates; and (10) Asphalt grade. It was found that mixing temperature, mixing time, rubber type, and asphalt grade all have significant effects upon the behavior of asphalt-rubber mixtures. Significant variability was also noticed in different laboratory batch replications. Varying laboratory test temperature and force-ductility elongation rate revealed further differences in asphalt-rubber mixtures.

  14. 49 CFR 174.102 - Forbidden mixed loading and storage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...

  15. 49 CFR 174.102 - Forbidden mixed loading and storage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...

  16. 49 CFR 174.102 - Forbidden mixed loading and storage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...

  17. EFFECTS OF MIXING AND AGING ON WATER QUALITY IN DISTRIBUTION SYSTEM STORAGE FACILITIES

    EPA Science Inventory

    Aging of water in distribution system storage facilities can lead to deterioration of the water quality due to loss of disinfectant residual and bacterial regrowth. Facilities should be operated to insure that the age of the water is not excessive taking into account the quality...

  18. 49 CFR 174.102 - Forbidden mixed loading and storage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...

  19. 49 CFR 174.102 - Forbidden mixed loading and storage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...

  20. 9 CFR 354.34 - Application for inspection service in official plants; approval.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... sewer, cesspool, sedimentation tank, etc. (13) Approximate rate of production—indicate hourly rate of..., if so, specify such uses. (10) Hot water facilities—specify facilities such as boilers, storage tanks, mixing valves, etc., and indicate the size and number of boilers and storage tanks. (11) Specify number...

  1. Dynamic-RAM Data Storage Unit

    NASA Technical Reports Server (NTRS)

    Sturman, J. C.

    1985-01-01

    Dynamic random-access-memory (RAM) data delay and storage unit developed to insure data received from satellite is stored and not lost when satellite is not within range of ground station. Stores 256K of serial data, with independent read and write capability.

  2. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 204: STORAGE BUNKERS, NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Corrective Action Unit (CAU) 330 consists of four Corrective Action Sites (CASs) located in Areas 6, 22, and 23 of the Nevada Test Site (NTS). The unit is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) as CAU 330: Areas 6, 22, and 23 Tanks and Spill Sites. CAU 330 consists of the following CASs: CAS 06-02-04, Underground Storage Tank (UST) and Piping CAS 22-99-06, Fuel Spill CAS 23-01-02, Large Aboveground Storage Tank (AST) Farm CAS 23-25-05, Asphalt Oil Spill/Tar Release

  3. Effect of dietary adipic acid and corn dried distillers grains with solubles on laying hen performance and nitrogen loss from stored excreta with or without sodium bisulfate.

    PubMed

    Romero, C; Abdallh, M E; Powers, W; Angel, R; Applegate, T J

    2012-05-01

    Effects of dietary adipic acid (0 vs. 1%) and corn dried distillers grains with solubles (DDGS; 0 vs. 20%) were evaluated on hen performance and egg characteristics from 26 to 34 wk of age. Four isocaloric and isonitrogenous diets were randomly assigned to blocks of 6 consecutive cages (36 cages per diet; 2 hens per cage). On wk 2 and 7 of the experiment, excreta were collected by cage block, mixed, and equally split into 2 containers. Sodium bisulfate (SBS) was spread (8.8 kg/100 m(2)) on the top surface of half of the containers. All containers were stored uncovered for 14 d at room temperature. Excreta pH, DM, and N content were measured on d 0, 7, and 14 of storage. Feed intake (112 g/d per hen), egg production (96.1%), and egg specific gravity (1.079 g/g) were not affected by diet. On excreta collection day, a synergy (P = 0.014) between dietary adipic acid and DDGS was detected, as the lowest excreta pH was obtained with the diet including both adipic acid and DDGS. On d 7 of storage, excreta pH was still reduced by dietary adipic acid (P = 0.046) and DDGS (P < 0.001), but a week later, only dietary DDGS decreased excreta pH (8.91 vs. 9.21; P < 0.001). Whereas dietary adipic acid had no influence on excreta N loss, excreta from hens fed 20% DDGS lost 19.7% more N (P = 0.039) during storage than hens not eating DDGS. Surface amendment of excreta with SBS increased excreta DM content, with the effect being even more marked on d 14 of storage (increase of 6.7 percentage units; P < 0.001), consistently decreased excreta pH during storage (P < 0.001) and reduced N loss by 26.1% for the 14 d of storage period.

  4. Geologic framework for the national assessment of carbon dioxide storage resources─South Florida Basin: Chapter L in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Roberts-Ashby, Tina L.; Brennan, Sean T.; Merrill, Matthew D.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.

    2015-08-26

    This report presents five storage assessment units (SAUs) that have been identified as potentially suitable for geologic carbon dioxide sequestration within a 35,075-square-mile area that includes the entire onshore and State-water portions of the South Florida Basin. Platform-wide, thick successions of laterally extensive carbonates and evaporites deposited in highly cyclic depositional environments in the South Florida Basin provide several massive, porous carbonate reservoirs that are separated by evaporite seals. For each storage assessment unit identified within the basin, the areal distribution of the reservoir-seal couplet identified as suitable for geologic Carbon dioxide sequestration is presented, along with a description of the geologic characteristics that influence the potential carbon dioxide storage volume and reservoir performance. On a case-by-case basis, strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are also discussed. Geologic information presented in this report has been employed to calculate potential storage capacities for carbon dioxide sequestration in the storage assessment units assessed herein, although complete assessment results are not contained in this report.

  5. Mixed finite-element formulations in piezoelectricity and flexoelectricity

    PubMed Central

    2016-01-01

    Flexoelectricity, the linear coupling of strain gradient and electric polarization, is inherently a size-dependent phenomenon. The energy storage function for a flexoelectric material depends not only on polarization and strain, but also strain-gradient. Thus, conventional finite-element methods formulated solely on displacement are inadequate to treat flexoelectric solids since gradients raise the order of the governing differential equations. Here, we introduce a computational framework based on a mixed formulation developed previously by one of the present authors and a colleague. This formulation uses displacement and displacement-gradient as separate variables which are constrained in a ‘weighted integral sense’ to enforce their known relation. We derive a variational formulation for boundary-value problems for piezo- and/or flexoelectric solids. We validate this computational framework against available exact solutions. Our new computational method is applied to more complex problems, including a plate with an elliptical hole, stationary cracks, as well as tension and shear of solids with a repeating unit cell. Our results address several issues of theoretical interest, generate predictions of experimental merit and reveal interesting flexoelectric phenomena with potential for application. PMID:27436967

  6. Mixed finite-element formulations in piezoelectricity and flexoelectricity.

    PubMed

    Mao, Sheng; Purohit, Prashant K; Aravas, Nikolaos

    2016-06-01

    Flexoelectricity, the linear coupling of strain gradient and electric polarization, is inherently a size-dependent phenomenon. The energy storage function for a flexoelectric material depends not only on polarization and strain, but also strain-gradient. Thus, conventional finite-element methods formulated solely on displacement are inadequate to treat flexoelectric solids since gradients raise the order of the governing differential equations. Here, we introduce a computational framework based on a mixed formulation developed previously by one of the present authors and a colleague. This formulation uses displacement and displacement-gradient as separate variables which are constrained in a 'weighted integral sense' to enforce their known relation. We derive a variational formulation for boundary-value problems for piezo- and/or flexoelectric solids. We validate this computational framework against available exact solutions. Our new computational method is applied to more complex problems, including a plate with an elliptical hole, stationary cracks, as well as tension and shear of solids with a repeating unit cell. Our results address several issues of theoretical interest, generate predictions of experimental merit and reveal interesting flexoelectric phenomena with potential for application.

  7. Phosphonitrilic Fluoroelastomer Coated Fabrics for Collapsible Fuel Storage Tanks

    DTIC Science & Technology

    1979-07-01

    Coated F,,brics .*.... *• .. ...... ..... •---*..,- *... 97 36. Stabilizer Masterbatch Formulations R21960 and -601. 58 37- Banbury "BR" Mixes of P®FO...minutes total mix time. The mix is then dumped. Curing agent is then added to the masterbatch banded on a mill. Ambient temperature mills were generally...maximum flow. 0 minutes-load polymer. speed: slow (77 rpm) 2 minutes-add fillers 7 minutes-add stabilizer masterbatch 15 minutevk-dunip mix To obtain as

  8. 40 CFR 63.703 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gaseous HAP emitted from each solvent storage tank, piece of mix preparation equipment, coating operation..., piece of mix preparation equipment, coating operation, waste handling device, and condenser vent in... of this method is sufficient to meet the requirements of paragraph (c)(1) or (2) of this section. (4...

  9. Estimating the value of electricity storage in PJM: Arbitrage and some welfare effects

    DOE PAGES

    Sioshansi, Ramteen; Denholm, Paul; Jenkin, Thomas; ...

    2008-10-31

    Here, significant increases in prices and price volatility of natural gas and electricity have raised interest in the potential economic opportunities for electricity storage. In this paper, we analyze the arbitrage value of a price-taking storage device in PJM during the six-year period from 2002 to 2007, to understand the impact of fuel prices, transmission constraints, efficiency, storage capacity, and fuel mix. The impact of load-shifting for larger amounts of storage, where reductions in arbitrage are offset by shifts in consumer and producer surplus as well as increases in social welfare from a variety of sources, is also considered.

  10. Improved solar heating systems

    DOEpatents

    Schreyer, J.M.; Dorsey, G.F.

    1980-05-16

    An improved solar heating system is described in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75 to 180/sup 0/F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing ad releasing heat for distribution.

  11. Solar heating system

    DOEpatents

    Schreyer, James M.; Dorsey, George F.

    1982-01-01

    An improved solar heating system in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75.degree. to 180.degree. F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing and releasing heat for distribution.

  12. Enhancing uniformity and overall quality of red cell concentrate with anaerobic storage

    PubMed Central

    Yoshida, Tatsuro; Blair, Abbejane; D'Alessandro, Angelo; Nemkov, Travis; Dioguardi, Michael; Silliman, Christopher C.; Dunham, Andrew

    2017-01-01

    Background Recent research focused on understanding stored red blood cell (RBC) quality has demonstrated high variability in measures of RBC function and health across units. Studies have historically linked this high variability to variations in processing, storage method, and age. More recently, a large number of studies have focused on differences in donor demographics, donor iron sufficiency, and genetic predisposition of the donor to poor storage, particularly through mechanisms of accelerated oxidative damage. A study was undertaken to evaluate a potential additional source of unit to unit variation in stored RBC: the role of variable percent oxygen saturation (%SO2) levels on blood quality parameters during storage. Materials and methods %SO2 data from 492 LR-RBC/AS-3 units used for internal and external collaborative research was included in the analysis. Whole blood units were processed into red blood cells, AS-3 added, leucocyte reduced, in compliance with American Association of Blood Banks guidelines. LR-RBC/AS-3 products were subsequently analysed for %SO2 levels within 3–24 hours of phlebotomy using a co-oximeter. Separately, to evaluate the impact of pre-storage as well as increasing levels of %SO2 during storage, a pool-and-split study was performed. Four units of LR-RBC/AS-3 were split 6 ways; “as is” (control), hyperoxygenated to more than 90%, and four levels of pre-storage %SO2. The units were periodically sampled up to 42 days and analysed for %SO2, pCO2, methaemoglobin, ATP, 2,3-BPG as well as with the metabolomics workflow. Results The measured mean %SO2 in LR-RBC/AS-3 within 24 hours of collection was 45.9±17.5% with (32.7–61.0 IQR). %SO2 in all products increased to approximately 95–100% in three weeks. Measured blood quality parameters including ATP, % haemolysis, methaemoglobin, oxidised lipids, and GSH/GSSG indicated suppressed cellular metabolism and increased red cell degradation in response to higher %SO2 levels. Discussion The surprisingly high variability in starting %SO2 levels, coupled with negative impacts of high oxygen saturation on red blood cell quality indicates that oxygen levels may be an important and under-appreciated source of unit-to-unit variability in RBC quality. PMID:28263176

  13. Enhancing uniformity and overall quality of red cell concentrate with anaerobic storage.

    PubMed

    Yoshida, Tatsuro; Blair, Abbejane; D'alessandro, Angelo; Nemkov, Travis; Dioguardi, Michael; Silliman, Christopher C; Dunham, Andrew

    2017-03-01

    Recent research focused on understanding stored red blood cell (RBC) quality has demonstrated high variability in measures of RBC function and health across units. Studies have historically linked this high variability to variations in processing, storage method, and age. More recently, a large number of studies have focused on differences in donor demographics, donor iron sufficiency, and genetic predisposition of the donor to poor storage, particularly through mechanisms of accelerated oxidative damage. A study was undertaken to evaluate a potential additional source of unit to unit variation in stored RBC: the role of variable percent oxygen saturation (%SO 2 ) levels on blood quality parameters during storage. %SO 2 data from 492 LR-RBC/AS-3 units used for internal and external collaborative research was included in the analysis. Whole blood units were processed into red blood cells, AS-3 added, leucocyte reduced, in compliance with American Association of Blood Banks guidelines. LR-RBC/AS-3 products were subsequently analysed for %SO 2 levels within 3-24 hours of phlebotomy using a co-oximeter. Separately, to evaluate the impact of pre-storage as well as increasing levels of %SO 2 during storage, a pool-and-split study was performed. Four units of LR-RBC/AS-3 were split 6 ways; "as is" (control), hyperoxygenated to more than 90%, and four levels of pre-storage %SO 2 . The units were periodically sampled up to 42 days and analysed for %SO 2 , pCO 2 , methaemoglobin, ATP, 2,3-BPG as well as with the metabolomics workflow. The measured mean %SO 2 in LR-RBC/AS-3 within 24 hours of collection was 45.9±17.5% with (32.7-61.0 IQR). %SO 2 in all products increased to approximately 95-100% in three weeks. Measured blood quality parameters including ATP, % haemolysis, methaemoglobin, oxidised lipids, and GSH/GSSG indicated suppressed cellular metabolism and increased red cell degradation in response to higher %SO 2 levels. The surprisingly high variability in starting %SO 2 levels, coupled with negative impacts of high oxygen saturation on red blood cell quality indicates that oxygen levels may be an important and under-appreciated source of unit-to-unit variability in RBC quality.

  14. 7 CFR 810.804 - Grades and grade requirements for mixed grain.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false Grades and grade requirements for mixed grain. 810.804... OFFICIAL UNITED STATES STANDARDS FOR GRAIN United States Standards for Mixed Grain Grades and Grade Requirements § 810.804 Grades and grade requirements for mixed grain. (a) U.S. Mixed Grain (grade). Mixed grain...

  15. 7 CFR 810.804 - Grades and grade requirements for mixed grain.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Grades and grade requirements for mixed grain. 810.804... OFFICIAL UNITED STATES STANDARDS FOR GRAIN United States Standards for Mixed Grain Grades and Grade Requirements § 810.804 Grades and grade requirements for mixed grain. (a) U.S. Mixed Grain (grade). Mixed grain...

  16. 7 CFR 810.804 - Grades and grade requirements for mixed grain.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 7 2012-01-01 2012-01-01 false Grades and grade requirements for mixed grain. 810.804... OFFICIAL UNITED STATES STANDARDS FOR GRAIN United States Standards for Mixed Grain Grades and Grade Requirements § 810.804 Grades and grade requirements for mixed grain. (a) U.S. Mixed Grain (grade). Mixed grain...

  17. 7 CFR 810.804 - Grades and grade requirements for mixed grain.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 7 2013-01-01 2013-01-01 false Grades and grade requirements for mixed grain. 810.804... OFFICIAL UNITED STATES STANDARDS FOR GRAIN United States Standards for Mixed Grain Grades and Grade Requirements § 810.804 Grades and grade requirements for mixed grain. (a) U.S. Mixed Grain (grade). Mixed grain...

  18. 7 CFR 810.804 - Grades and grade requirements for mixed grain.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Grades and grade requirements for mixed grain. 810.804... OFFICIAL UNITED STATES STANDARDS FOR GRAIN United States Standards for Mixed Grain Grades and Grade Requirements § 810.804 Grades and grade requirements for mixed grain. (a) U.S. Mixed Grain (grade). Mixed grain...

  19. Capital Provision for University Libraries in the United Kingdom--Comments on the Atkinson Report

    ERIC Educational Resources Information Center

    Taylor, Colin R.

    1977-01-01

    United Kingdom norms for libraries are reviewed and the effect they would have on Australian university libraries is examined. Focus is on book storage, future growth provision, reader places, administration, reserve storage, and special collections. (LBH)

  20. Kitchen Units for the Classroom.

    ERIC Educational Resources Information Center

    Illinois Univ., Urbana. Agricultural Experiment Station.

    This study is concerned with functional standards for storage of equipment, use of space, and arrangement of work centers in kitchen units for four students within a high school foods laboratory. Lists of equipment and measurements for storage areas are given for each work center. (FS)

  1. Red blood cell storage time and transfusion: current practice, concerns and future perspectives

    PubMed Central

    García-Roa, María; del Carmen Vicente-Ayuso, María; Bobes, Alejandro M.; Pedraza, Alexandra C.; González-Fernández, Ataúlfo; Martín, María Paz; Sáez, Isabel; Seghatchian, Jerard; Gutiérrez, Laura

    2017-01-01

    Red blood cells (RBCs) units are the most requested transfusion product worldwide. Indications for transfusion include symptomatic anaemia, acute sickle cell crisis, and acute blood loss of more than 30% of the blood volume, with the aim of restoring tissue oxygen delivery. However, stored RBCs from donors are not a qualitative equal product, and, in many ways, this is a matter of concern in the transfusion practice. Besides donor-to-donor variation, the storage time influences the RBC unit at the qualitative level, as RBCs age in the storage bag and are exposed to the so-called storage lesion. Several studies have shown that the storage lesion leads to post-transfusion enhanced clearance, plasma transferrin saturation, nitric oxide scavenging and/or immunomodulation with potential unwanted transfusion-related clinical outcomes, such as acute lung injury or higher mortality rate. While, to date, several studies have claimed the risk or deleterious effects of “old” vs “young” RBC transfusion regimes, it is still a matter of debate, and consideration should be taken of the clinical context. Transfusion-dependent patients may benefit from transfusion with “young” RBC units, as it assures longer inter-transfusion periods, while transfusion with “old” RBC units is not itself harmful. Unbiased Omics approaches are being applied to the characterisation of RBC through storage, to better understand the (patho)physiological role of microparticles (MPs) that are found naturally, and also on stored RBC units. Perhaps RBC storage time is not an accurate surrogate for RBC quality and there is a need to establish which parameters do indeed reflect optimal efficacy and safety. A better Omics characterisation of components of “young” and “old” RBC units, including MPs, donor and recipient, might lead to the development of new therapies, including the use of engineered RBCs or MPs as cell-based drug delivering tools, or cost-effective personalised transfusion strategies. PMID:28518049

  2. 41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...

  3. 41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...

  4. 41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...

  5. Storage Time and Urine Biomarker Levels in the ASSESS-AKI Study

    PubMed Central

    Liu, Kathleen D.; Siew, Edward D.; Reeves, W. Brian; Himmelfarb, Jonathan; Go, Alan S.; Hsu, Chi-yuan; Bennett, Michael R.; Devarajan, Prasad; Ikizler, T. Alp; Kaufman, James S.; Kimmel, Paul L.; Chinchilli, Vernon M.; Parikh, Chirag R.

    2016-01-01

    Background Although stored urine samples are often used in biomarker studies focused on acute and chronic kidney disease, how storage time impacts biomarker levels is not well understood. Methods 866 subjects enrolled in the NIDDK-sponsored ASsessment, Serial Evaluation, and Subsequent Sequelae in Acute Kidney Injury (ASSESS-AKI) Study were included. Samples were processed under standard conditions and stored at -70°C until analyzed. Kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL), interleukin-18 (IL-18), and liver fatty acid binding protein (L-FABP) were measured in urine samples collected during the index hospitalization or an outpatient visit 3 months later. Mixed effects models were used to determine the effect of storage time on biomarker levels and stratified by visit. Results Median storage was 17.8 months (25–75% IQR 10.6–23.7) for samples from the index hospitalization and 14.6 months (IQR 7.3–20.4) for outpatient samples. In the mixed effects models, the only significant association between storage time and biomarker concentration was for KIM-1 in outpatient samples, where each month of storage was associated with a 1.7% decrease (95% CI -3% to -0.3%). There was no relationship between storage time and KIM-1 levels in samples from the index hospitalization. Conclusion There was no significant impact of storage time over a median of 18 months on urine KIM-1, NGAL, IL-18 or L-FABP in hospitalized samples; a statistically significant effect towards a decrease over time was noted for KIM-1 in outpatient samples. Additional studies are needed to determine whether longer periods of storage at -70°C systematically impact levels of these analytes. PMID:27788160

  6. Storage Time and Urine Biomarker Levels in the ASSESS-AKI Study.

    PubMed

    Liu, Kathleen D; Siew, Edward D; Reeves, W Brian; Himmelfarb, Jonathan; Go, Alan S; Hsu, Chi-Yuan; Bennett, Michael R; Devarajan, Prasad; Ikizler, T Alp; Kaufman, James S; Kimmel, Paul L; Chinchilli, Vernon M; Parikh, Chirag R

    2016-01-01

    Although stored urine samples are often used in biomarker studies focused on acute and chronic kidney disease, how storage time impacts biomarker levels is not well understood. 866 subjects enrolled in the NIDDK-sponsored ASsessment, Serial Evaluation, and Subsequent Sequelae in Acute Kidney Injury (ASSESS-AKI) Study were included. Samples were processed under standard conditions and stored at -70°C until analyzed. Kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL), interleukin-18 (IL-18), and liver fatty acid binding protein (L-FABP) were measured in urine samples collected during the index hospitalization or an outpatient visit 3 months later. Mixed effects models were used to determine the effect of storage time on biomarker levels and stratified by visit. Median storage was 17.8 months (25-75% IQR 10.6-23.7) for samples from the index hospitalization and 14.6 months (IQR 7.3-20.4) for outpatient samples. In the mixed effects models, the only significant association between storage time and biomarker concentration was for KIM-1 in outpatient samples, where each month of storage was associated with a 1.7% decrease (95% CI -3% to -0.3%). There was no relationship between storage time and KIM-1 levels in samples from the index hospitalization. There was no significant impact of storage time over a median of 18 months on urine KIM-1, NGAL, IL-18 or L-FABP in hospitalized samples; a statistically significant effect towards a decrease over time was noted for KIM-1 in outpatient samples. Additional studies are needed to determine whether longer periods of storage at -70°C systematically impact levels of these analytes.

  7. A spatial emergy model for Alachua County, Florida

    NASA Astrophysics Data System (ADS)

    Lambert, James David

    A spatial model of the distribution of energy flows and storages in Alachua County, Florida, was created and used to analyze spatial patterns of energy transformation hierarchy in relation to spatial patterns of human settlement. Emergy, the available energy of one kind previously required directly or indirectly to make a product or service, was used as a measure of the quality of the different forms of energy flows and storages. Emergy provides a common unit of measure for comparing the productive contributions of natural processes with those of economic and social processes---it is an alternative to using money for measuring value. A geographic information system was used to create a spatial model and make maps that show the distribution and magnitude of different types of energy and emergy flows and storages occurring in one-hectare land units. Energy transformities were used to convert individual energy flows and storages into emergy units. Maps of transformities were created that reveal a clear spatial pattern of energy transformation hierarchy. The maps display patterns of widely-dispersed areas with lower transformity energy flows and storages, and smaller, centrally-located areas with higher transformities. Energy signature graphs and spatial unit transformities were used to characterize and compare the types and amounts of energy being consumed and stored according to land use classification, planning unit, and neighborhood categories. Emergy ratio maps and spatial unit ratios were created by dividing the values for specific emergy flows or storages by the values for other emergy flows or storages. Spatial context analysis was used to analyze the spatial distribution patterns of mean and maximum values for emergy flows and storages. The modeling method developed for this study is general and applicable to all types of landscapes and could be applied at any scale. An advantage of this general approach is that the results of other studies using this method will be directly comparable with the results of this study. The results and conclusions of this study reinforce the hypothesis that an urban landscape will develop a predictable spatial pattern that can be described in terms of a universal energy transformation hierarchy.

  8. Risk, liability, and economic issues with long-term CO2 storage—A review

    USGS Publications Warehouse

    Anderson, Steven T.

    2017-01-01

    Given a scarcity of commercial-scale carbon capture and storage (CCS) projects, there is a great deal of uncertainty in the risks, liability, and their cost implications for geologic storage of carbon dioxide (CO2). The probabilities of leakage and the risk of induced seismicity could be remote, but the volume of geologic CO2 storage (GCS) projected to be necessary to have a significant impact on increasing CO2 concentrations in the atmosphere is far greater than the volumes of CO2 injected thus far. National-level estimates of the technically accessible CO2storage resource (TASR) onshore in the United States are on the order of thousands of gigatons of CO2 storage capacity, but such estimates generally assume away any pressure management issues. Pressure buildup in the storage reservoir is expected to be a primary source of risk associated with CO2 storage, and only a fraction of the theoretical TASR could be available unless the storage operator extracts the saltwater brines or other formation fluids that are already present in the geologic pore space targeted for CO2 storage. Institutions, legislation, and processes to manage the risk, liability, and economic issues with CO2 storage in the United States are beginning to emerge, but will need to progress further in order to allow a commercial-scale CO2 storage industry to develop in the country. The combination of economic tradeoffs, property rights definitions, liability issues, and risk considerations suggests that CO2 storage offshore of the United States may be more feasible than onshore, especially during the current (early) stages of industry development.

  9. Specific storage volumes: A useful tool for CO2 storage capacity assessment

    USGS Publications Warehouse

    Brennan, S.T.; Burruss, R.C.

    2006-01-01

    Subsurface geologic strata have the potential to store billions of tons of anthropogenic CO2; therefore, geologic carbon sequestration can be an effective mitigation tool used to slow the rate at which levels of atmospheric CO2 are increasing. Oil and gas reservoirs, coal beds, and saline reservoirs can be used for CO2 storage; however, it is difficult to assess and compare the relative storage capacities of these different settings. Typically, CO2 emissions are reported in units of mass, which are not directly applicable to comparing the CO2 storage capacities of the various storage targets. However, if the emission values are recalculated to volumes per unit mass (specific volume) then the volumes of geologic reservoirs necessary to store CO2 emissions from large point sources can be estimated. The factors necessary to convert the mass of CO2 emissions to geologic storage volume (referred to here as Specific Storage Volume or 'SSV') can be reported in units of cubic meters, cubic feet, and petroleum barrels. The SSVs can be used to estimate the reservoir volume needed to store CO2 produced over the lifetime of an individual point source, and to identify CO2 storage targets of sufficient size to meet the demand from that given point source. These storage volumes also can then be projected onto the land surface to outline a representative "footprint," which marks the areal extent of storage. This footprint can be compared with the terrestrial carbon sequestration capacity of the same land area. The overall utility of this application is that the total storage capacity of any given parcel of land (from surface to basement) can be determined, and may assist in making land management decisions. ?? Springer Science+Business Media, LLC 2006.

  10. Requirements to the procedure and stages of innovative fuel development

    NASA Astrophysics Data System (ADS)

    Troyanov, V.; Zabudko, L.; Grachyov, A.; Zhdanova, O.

    2016-04-01

    According to the accepted current understanding under the nuclear fuel we will consider the assembled active zone unit (Fuel assembly) with its structural elements, fuel rods, pellet column, structural materials of fuel rods and fuel assemblies. The licensing process includes justification of safe application of the proposed modifications, including design-basis and experimental justification of the modified items under normal operating conditions and in violation of normal conditions, including accidents as well. Besides the justification of modified units itself, it is required to show the influence of modifications on the performance and safety of the other Reactor Unit’ and Nuclear Plant’ elements (e.g. burst can detection system, transportation and processing operations during fuel handling), as well as to justify the new standards of fuel storage etc. Finally, the modified fuel should comply with the applicable regulations, which often becomes a very difficult task, if only because those regulations, such as the NP-082-07, are not covered modification issues. Making amendments into regulations can be considered as the only solution, but the process is complicated and requires deep grounds for amendments. Some aspects of licensing new nuclear fuel are considered the example of mixed nitride uranium -plutonium fuel application for the BREST reactor unit.

  11. 15 CFR 2008.14 - Storage.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...

  12. 15 CFR 2008.14 - Storage.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...

  13. 15 CFR 2008.14 - Storage.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...

  14. 15 CFR 2008.14 - Storage.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...

  15. 15 CFR 2008.14 - Storage.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...

  16. Thermodynamic analysis of a thermal storage unit under the influence of nano-particles added to the phase change material and/or the working fluid

    NASA Astrophysics Data System (ADS)

    Abolghasemi, Mehran; Keshavarz, Ali; Mehrabian, Mozaffar Ali

    2012-11-01

    The thermal storage unit consists of two concentric cylinders where the working fluid flows through the internal cylinder and the annulus is filled with a phase change material. The system carries out a cyclic operation; each cycle consists of two processes. In the charging process the hot working fluid enters the internal cylinder and transfers heat to the phase change material. In the discharging process the cold working fluid enters the internal cylinder and absorbs heat from the phase change material. The differential equations governing the heat transfer between the two media are solved numerically. The numerical results are compared with the experimental results available in the literature. The performance of an energy storage unit is directly related to the thermal conductivity of nano-particles. The energy consumption of a residential unit whose energy is supplied by a thermal storage system can be reduced by 43 % when using nano-particles.

  17. Unitized Regenerative Fuel Cell System Gas Dryer/Humidifier Analytical Model Development

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian

    2004-01-01

    A lightweight Unitized Regenerative Fuel Cell (URFC) Energy Storage System concept is being developed at the NASA Glenn Research Center (GRC). This Unitized Regenerative Fuel Cell System (URFCS) is unique in that it uses Regenerative Gas Dryers/Humidifiers (RGD/H) that are mounted on the surface of the gas storage tanks that act as the radiators for thermal control of the Unitized Regenerative Fuel Cell System (URFCS). As the gas storage tanks cool down during URFCS charging the RGD/H dry the hydrogen and oxygen gases produced by electrolysis. As the gas storage tanks heat up during URFCS discharging, the RGD/H humidify the hydrogen and oxygen gases used by the fuel cell. An analytical model was developed to simulate the URFCS RGD/H. The model is in the form of a Microsoft (registered trademark of Microsoft Corporation) Excel worksheet that allows the investigation of the RGD/H performance. Finite Element Analysis (FEA) modeling of the RGD/H and the gas storage tank wall was also done to analyze spatial temperature distribution within the RGD/H and the localized tank wall. Test results obtained from the testing of the RGD/H in a thermal vacuum environment were used to corroborate the analyses.

  18. Failure analysis of storage tank component in LNG regasification unit using fault tree analysis method (FTA)

    NASA Astrophysics Data System (ADS)

    Mulyana, Cukup; Muhammad, Fajar; Saad, Aswad H.; Mariah, Riveli, Nowo

    2017-03-01

    Storage tank component is the most critical component in LNG regasification terminal. It has the risk of failure and accident which impacts to human health and environment. Risk assessment is conducted to detect and reduce the risk of failure in storage tank. The aim of this research is determining and calculating the probability of failure in regasification unit of LNG. In this case, the failure is caused by Boiling Liquid Expanding Vapor Explosion (BLEVE) and jet fire in LNG storage tank component. The failure probability can be determined by using Fault Tree Analysis (FTA). Besides that, the impact of heat radiation which is generated is calculated. Fault tree for BLEVE and jet fire on storage tank component has been determined and obtained with the value of failure probability for BLEVE of 5.63 × 10-19 and for jet fire of 9.57 × 10-3. The value of failure probability for jet fire is high enough and need to be reduced by customizing PID scheme of regasification LNG unit in pipeline number 1312 and unit 1. The value of failure probability after customization has been obtained of 4.22 × 10-6.

  19. Maintenance of platelet in vitro properties during 7-day storage in M-sol with a 30-hour interruption of agitation.

    PubMed

    Wagner, Stephen J; Myrup, Andrew; Awatefe, Helen; Thompson-Montgomery, Dedeene; Hirayama, Junichi; Skripchenko, Andrey

    2008-12-01

    Extensive periods without agitation can occasionally occur during platelet (PLT) shipment and can affect PLT quality during 5- to 7-day storage. The use of buffer-containing PLT additive solutions (ASs) may better preserve PLT quality during storage by maintaining PLT pH and other in vitro variables. A newly described bicarbonate-containing AS, M-sol, was compared to plasma for preservation of whole blood-derived PLT concentrates in which a 30-hour interruption of agitation was included. ABO-identical PLT-rich plasma intermediate products were pooled in sets of four, split, and centrifuged with subsequent plasma expression (n = 12). Two units were resuspended with M-sol AS to produce a 70 percent solution/30 percent plasma PLT concentrate; 2 units were resuspended in 100 percent plasma. One M-sol resuspended unit and 1 plasma unit were held on a laboratory bench in a standard shipping box for 30 hours between Day 2 and Day 3, while the other M-sol and plasma unit were continuously agitated. Standard in vitro testing for PLT quality variables on each set of 4 units was performed during storage (n = 12). Interrupting agitation of PLTs suspended in M-sol resulted in less of a pH decrement during storage than that of PLTs suspended in 100 percent plasma. On Days 5 and 7, the pH differences between M-sol and plasma units were 0.56 and 0.75 pH units, respectively (p < 0.0003). In addition, PLTs suspended in M-sol and subjected to an interruption of agitation had lesser Day 7 CD62+ cells, glucose utilization, and lactate production and greater hypotonic stress response, morphology, swirling, and aggregation response than those suspended in plasma (p

  20. Effect of ensiling process of total mixed ration on fermentation profile, nutrient loss and in situ ruminal degradation characteristics of diet.

    PubMed

    Miyaji, Makoto; Matsuyama, Hiroki; Nonaka, Kazuhisa

    2017-01-01

    This experiment aimed to determine the changes in chemical composition, fermentation profile, in situ disappearance characteristics, and nutrient losses of ensiled total mixed ration (TMR) containing steam-flaked corn or brown rice (BR) during storage. TMRs for dairy cows, containing either steam-flaked corn or BR at 31.9% with 15.2% rye silage, 40.5% alfalfa silage, 5.0% beet pulp and 7.0% soybean meal, were prepared (dry matter (DM) basis). Each TMR was placed in a plastic drum silo, stored at 23°C in an air-conditioned room and sampled 0, 7, 14, 30, 90 and 210 days after preparation. In both grain sources, the fermentation products increased, while DM and starch storage losses increased and starch content greatly decreased during storage. The rapidly degradable fraction and effective ruminal degradability of DM, crude protein and starch increased during storage. These changes of dietary characteristics were large during 30 days of storage, but small after 90 days of storage. Replacing corn with BR led to increased fermentation products, starch loss and effective ruminal degradability of the ensiled TMR. These results indicate that the ensiling process of TMR changes the dietary characteristics and replacing corn with BR in TMR had a large impact on these dietary characteristics. © 2016 Japanese Society of Animal Science.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Electric utilities operating nuclear power plants have found themselves in a regulatory Catch-22; extremely limited treatment and disposal capacity is available for their mixed wastes, yet EPA has interpreted RCRA in such a way that long-term storage of the wastes is prohibited. A group of utilities received no relief from this predicament when a court recently rejected their petition for review of EPA`s interpretation of the RCRA mixed-waste storage prohibition. The decision was rendered by the U.S. Court of Appeals for the District of Columbia Circuit on June 18, 1993 (Edison Electric Institute et al. v. U.S. EPA, Docket Number:more » 91-1586).« less

  2. 77 FR 3766 - Southwestern Gas Storage Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-25

    ... Storage Technical Conference Notice of Public Conference On December 13, 2011, the Secretary issued formal... related to natural gas storage development in the southwestern United States, to be held at the Radisson... to speak from numerous individuals representing diverse interests associated with storage development...

  3. The North American Energy System: Overview of the 3rd Chapter of SOCCR-2

    NASA Astrophysics Data System (ADS)

    Marcotullio, P. J.

    2016-12-01

    North America, including Canada, Mexico and the United States, has a large and complex energy system, which includes the extraction and conversion of primary energy sources and their storage, transmission, distribution and ultimate end use in the building, transportation and industrial sectors. The chapter overviews this system focusing on our understanding of the energy trends and system feedback dynamics, key drivers of change, and subsequent carbon emissions and the basis for carbon management. We also put the carbon emissions from the North American system in global context. Highlights include the changes to the system (sources, fuel mix, drivers, infrastructure, etc.,) over the past decade, and a review of scenarios that provide glimpses into future emissions levels and meeting the requirements for decarbonization in the medium and longer term.

  4. Environmental Assessment for the Operation of the Glass Melter Thermal Treatment Unit at the US Department of Energy`s Mound Plant, Miamisburg, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-06-01

    The glass melter would thermally treat mixed waste (hazardous waste contaminated with radioactive constituents largely tritium, Pu-238, and/or Th-230) that was generated at the Mound Plant and is now in storage, by stabilizing the waste in glass blocks. Depending on the radiation level of the waste, the glass melter may operate for 1 to 6 years. Two onsite alternatives and seven offsite alternatives were considered. This environmental assessment indicates that the proposed action does not constitute a major Federal action significantly affecting the human environment according to NEPA, and therefore the finding of no significant impact is made, obviating themore » need for an environmental impact statement.« less

  5. Storage of platelets: effects associated with high platelet content in platelet storage containers.

    PubMed

    Gulliksson, Hans; Sandgren, Per; Sjödin, Agneta; Hultenby, Kjell

    2012-04-01

    A major problem associated with platelet storage containers is that some platelet units show a dramatic fall in pH, especially above certain platelet contents. The aim of this study was a detailed investigation of the different in vitro effects occurring when the maximum storage capacity of a platelet container is exceeded as compared to normal storage. Buffy coats were combined in large-volume containers to create primary pools to be split into two equal aliquots for the preparation of platelets (450-520×10(9) platelets/unit) in SSP+ for 7-day storage in two containers (test and reference) with different platelet storage capacity (n=8). Exceeding the maximum storage capacity of the test platelet storage container resulted in immediate negative effects on platelet metabolism and energy supply, but also delayed effects on platelet function, activation and disintegration. Our study gives a very clear indication of the effects in different phases associated with exceeding the maximum storage capacity of platelet containers but throw little additional light on the mechanism initiating those negative effects. The problem appears to be complex and further studies in different media using different storage containers will be needed to understand the mechanisms involved.

  6. Lifetime of carbon capture and storage as a climate-change mitigation technology

    PubMed Central

    Szulczewski, Michael L.; MacMinn, Christopher W.; Herzog, Howard J.; Juanes, Ruben

    2012-01-01

    In carbon capture and storage (CCS), CO2 is captured at power plants and then injected underground into reservoirs like deep saline aquifers for long-term storage. While CCS may be critical for the continued use of fossil fuels in a carbon-constrained world, the deployment of CCS has been hindered by uncertainty in geologic storage capacities and sustainable injection rates, which has contributed to the absence of concerted government policy. Here, we clarify the potential of CCS to mitigate emissions in the United States by developing a storage-capacity supply curve that, unlike current large-scale capacity estimates, is derived from the fluid mechanics of CO2 injection and trapping and incorporates injection-rate constraints. We show that storage supply is a dynamic quantity that grows with the duration of CCS, and we interpret the lifetime of CCS as the time for which the storage supply curve exceeds the storage demand curve from CO2 production. We show that in the United States, if CO2 production from power generation continues to rise at recent rates, then CCS can store enough CO2 to stabilize emissions at current levels for at least 100 y. This result suggests that the large-scale implementation of CCS is a geologically viable climate-change mitigation option in the United States over the next century. PMID:22431639

  7. 41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...

  8. 41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...

  9. 41 CFR 302-8.106 - May I change from temporary to extended storage?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...

  10. 41 CFR 302-8.106 - May I change from temporary to extended storage?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...

  11. 41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...

  12. 41 CFR 302-8.106 - May I change from temporary to extended storage?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...

  13. A New Heat Supply System of Cogeneration for the Local Community

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Hideki; Hisazumi, Yoshinori; Asano, Hitoshi; Morita, Hikaru; Hori, Toshihiro; Matsumoto, Toshiki; Abiko, Tetsuo

    In order for economically viable distributed generation systems for local communities to be widely accepted, it is essential to develop an efficient and low-cost heat supply system. For this purpose, we propose a new heat supply system which we already presented at the ICOPE-05 Chicago. The key technology for the system is to connect compact heat supply units with a heat storage function installed in all the households of the local community, such as condominiums, by a single-loop of hot water pipe. A phase change material was used for the heat supply unit as the heat storage material. However, for easier handling and reducing the cost of the unit, we have developed a new heat supply unit whose heat storage tank is made of plastic. Hot water for space heating is used as the heat storage material. Further we constructed a heat supply system for 7 lived-in households with a 5 kW gas engine and a 42 kW boiler as the heat sources. Some experiments with a heat supply unit and a heat supply system, such as for heat storage and heat supply for peak demand were conducted. Additionally, dynamic simulations of heat demand by 50 households and a COP evaluation of a new CO2 heat pump system using low-temperature exhaust gas from the gas engine were also conducted.

  14. Thermal energy storage evaluation and life testing

    NASA Astrophysics Data System (ADS)

    Richter, R.

    1983-01-01

    Two thermal energy storage (TES) units which were built under a previous contract were tested with a Hi-Cap Vuilleumier cryogenic cooler in the facility of the Hughes Aircraft Corporation. The objective of the program was the evaluation of the behavior of the TES units as well as the determination of the temperature history of the three cold stages of the Vuilleumier cryogenic cooler during cyclic charging and discharging of the TES units. The test results have confirmed that thermal energy storage can provide the necessary thermal power to the hot cylinders of the Vuilleumier cryogenic cooler at the required operating temperatures. Thereby the continuous cooling capability of the cooler during an eclipse when no electrical power is available is being assured. The cold stage temperature amplitudes during a complete charge discharge cycle of the TES units were only about 10% of the amplitudes which were observed when the Hi-Cap Vuilleumier cryogenic cooler was operating without thermal energy storage backup in a simulated orbit of 54 minutes sun exposure and 18 minutes eclipse time. The themal conductivity of the molten thermal energy storage salt was apparently only a fraction of the thermal conductivity which had been assumed for the prediction of the upper heater temperatures. A redesign of the heater temperatures below 1480 degrees F which is now required for full charging of the TES units within 54 minutes with the present heater design.

  15. The failure analysis, redesign, and final preparation of the Brilliant Eyes Thermal Storage Unit for flight testing

    NASA Astrophysics Data System (ADS)

    Lamkin, T.; Whitney, Brian

    1995-09-01

    This paper describes the engineering thought process behind the failure analysis, redesign, and rework of the flight hardware for the Brilliant Eyes Thermal Storage Unit (BETSU) experiment. This experiment was designed to study the zero-g performance of 2-methylpentane as a suitable phase change material. This hydrocarbon served as the cryogenic storage medium for the BETSU experiment which was flown 04 Mar 94 on board Shuttle STS-62. Ground testing had indicated satisfactory performance of the BETSU at the 120 Kelvin design temperature. However, questions remained as to the micro-gravity performance of this unit; potential deviations in ground (1 g) versus space flight (0 g) performance, and how the unit would operate in a realistic space environment undergoing cyclical operation. The preparations and rework performed on the BETSU unit, which failed initial flight qualification, give insight and lessons learned to successfully develop and qualify a space flight experiment.

  16. Using a physically-based water flow model to explore the dynamics of transit times and mixing in a small agricultural catchment

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Heidbüchel, Ingo; Musolff, Andreas; Fleckenstein, Jan H.

    2017-04-01

    Catchment-scale transit time distributions (TTDs) for discharge and residence time distributions of the water in storage (RTDs) are promising tools to characterize the discharge and mixing behavior of a catchment and can help to interpret the associated solute loads to the stream in a spatially implicit way. TTDs and RTDs are dynamic in time, influenced by dynamic rainfall and evapotranspiration forcing, and changing groundwater storage in the catchment. In order to understand the links between the dynamics of TTDs and groundwater mixing in the small agricultural catchment Schäfertal, in central Germany, a 3D hydrological model was set up for the catchment using the fully coupled surface-subsurface numerical model HydroGeoSphere (HGS). The model is calibrated using discharge and groundwater level measurements, and runs transiently for a period of 10 years from 1997 to 2007. A particle tracking tool was implemented in HGS to track the movement of water parcels in the subsurface, outputting TTDs of channel discharge and RTDs of groundwater storage at daily intervals. Results show that the mean age of the discharge water is significantly younger than that of the water in storage, indicating a poorly mixed subsurface. Discharge preferentially samples faster flowing younger water originating from the more conductive top parts of the aquifer. Spatial variations of the age of water in storage are observed, highly influenced by aquifer heterogeneity. Computed StorAge Selection (SAS) functions [Rinaldo et al. 2015] show clear shifts in the discharge sampling preferences between wet and dry states: during wet states in winter and spring, discharge has a preference for younger water because the shallow flow paths are active due to high groundwater levels and low evapotranspiration. Conversely, during dry states in summer and autumn, discharge has a preference for older water because the shallow flow paths are inactive due to low groundwater levels and stronger evapotranspiration. Measured nitrate (NO3) loads in discharge, mainly originating from fertilizer in shallow soils, decrease significantly with decreasing wetness of the catchment. This trend confirms the shifts of discharge sampling preferences between wet and dry states. Reference: Rinaldo, A., P. Benettin, C. J. Harman, M. Hrachowitz, K. J. McGuire, Y. van der Velde, E. Bertuzzo, and G. Botter (2015), Storage selection functions: A coherent framework for quantifying how catchments store and release water and solutes, Water Resour. Res., 51, 4840-4847, doi:10.1002/2015WR017273.

  17. Robotics for mixed waste operations, demonstration description

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, C.R.

    The Department of Energy (DOE) Office of Technology Development (OTD) is developing technology to aid in the cleanup of DOE sites. Included in the OTD program are the Robotics Technology Development Program and the Mixed Waste Integrated Program. These two programs are working together to provide technology for the cleanup of mixed waste, which is waste that has both radioactive and hazardous constituents. There are over 240,000 cubic meters of mixed low level waste accumulated at DOE sites and the cleanup is expected to generate about 900,000 cubic meters of mixed low level waste over the next five years. Thismore » waste must be monitored during storage and then treated and disposed of in a cost effective manner acceptable to regulators and the states involved. The Robotics Technology Development Program is developing robotics technology to make these tasks safer, better, faster and cheaper through the Mixed Waste Operations team. This technology will also apply to treatment of transuranic waste. The demonstration at the Savannah River Site on November 2-4, 1993, showed the progress of this technology by DOE, universities and industry over the previous year. Robotics technology for the handling, characterization and treatment of mixed waste as well robotics technology for monitoring of stored waste was demonstrated. It was shown that robotics technology can make future waste storage and waste treatment facilities better, faster, safer and cheaper.« less

  18. Bulk energy storage increases United States electricity system emissions.

    PubMed

    Hittinger, Eric S; Azevedo, Inês M L

    2015-03-03

    Bulk energy storage is generally considered an important contributor for the transition toward a more flexible and sustainable electricity system. Although economically valuable, storage is not fundamentally a "green" technology, leading to reductions in emissions. We model the economic and emissions effects of bulk energy storage providing an energy arbitrage service. We calculate the profits under two scenarios (perfect and imperfect information about future electricity prices), and estimate the effect of bulk storage on net emissions of CO2, SO2, and NOx for 20 eGRID subregions in the United States. We find that net system CO2 emissions resulting from storage operation are nontrivial when compared to the emissions from electricity generation, ranging from 104 to 407 kg/MWh of delivered energy depending on location, storage operation mode, and assumptions regarding carbon intensity. Net NOx emissions range from -0.16 (i.e., producing net savings) to 0.49 kg/MWh, and are generally small when compared to average generation-related emissions. Net SO2 emissions from storage operation range from -0.01 to 1.7 kg/MWh, depending on location and storage operation mode.

  19. Hydrogen storage materials and method of making by dry homogenation

    DOEpatents

    Jensen, Craig M.; Zidan, Ragaiy A.

    2002-01-01

    Dry homogenized metal hydrides, in particular aluminum hydride compounds, as a material for reversible hydrogen storage is provided. The reversible hydrogen storage material comprises a dry homogenized material having transition metal catalytic sites on a metal aluminum hydride compound, or mixtures of metal aluminum hydride compounds. A method of making such reversible hydrogen storage materials by dry doping is also provided and comprises the steps of dry homogenizing metal hydrides by mechanical mixing, such as be crushing or ball milling a powder, of a metal aluminum hydride with a transition metal catalyst. In another aspect of the invention, a method of powering a vehicle apparatus with the reversible hydrogen storage material is provided.

  20. Development of a Probabilistic Assessment Methodology for Evaluation of Carbon Dioxide Storage

    USGS Publications Warehouse

    Burruss, Robert A.; Brennan, Sean T.; Freeman, P.A.; Merrill, Matthew D.; Ruppert, Leslie F.; Becker, Mark F.; Herkelrath, William N.; Kharaka, Yousif K.; Neuzil, Christopher E.; Swanson, Sharon M.; Cook, Troy A.; Klett, Timothy R.; Nelson, Philip H.; Schenk, Christopher J.

    2009-01-01

    This report describes a probabilistic assessment methodology developed by the U.S. Geological Survey (USGS) for evaluation of the resource potential for storage of carbon dioxide (CO2) in the subsurface of the United States as authorized by the Energy Independence and Security Act (Public Law 110-140, 2007). The methodology is based on USGS assessment methodologies for oil and gas resources created and refined over the last 30 years. The resource that is evaluated is the volume of pore space in the subsurface in the depth range of 3,000 to 13,000 feet that can be described within a geologically defined storage assessment unit consisting of a storage formation and an enclosing seal formation. Storage assessment units are divided into physical traps (PTs), which in most cases are oil and gas reservoirs, and the surrounding saline formation (SF), which encompasses the remainder of the storage formation. The storage resource is determined separately for these two types of storage. Monte Carlo simulation methods are used to calculate a distribution of the potential storage size for individual PTs and the SF. To estimate the aggregate storage resource of all PTs, a second Monte Carlo simulation step is used to sample the size and number of PTs. The probability of successful storage for individual PTs or the entire SF, defined in this methodology by the likelihood that the amount of CO2 stored will be greater than a prescribed minimum, is based on an estimate of the probability of containment using present-day geologic knowledge. The report concludes with a brief discussion of needed research data that could be used to refine assessment methodologies for CO2 sequestration.

  1. Carbon storage and sequestration by trees in urban and community areas of the United States

    Treesearch

    David J. Nowak; Eric J. Greenfield; Robert E. Hoehn; Elizabeth Lapoint

    2013-01-01

    Carbon storage and sequestration by urban trees in the United States was quantified to assess the magnitude and role of urban forests in relation to climate change. Urban tree field data from 28 cities and 6 states were used to determine the average carbon density per unit of tree cover. These data were applied to statewide urban tree cover measurements to determine...

  2. 7 CFR 51.309 - Condition after storage or transit.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...

  3. 7 CFR 51.309 - Condition after storage or transit.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...

  4. 7 CFR 51.309 - Condition after storage or transit.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...

  5. View from east to west of PAR site storage building; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View from east to west of PAR site storage building; formerly PAR dispensary - Stanley R. Mickelsen Safeguard Complex, Storage Building, Across street from Family Housing Units 110 & 111, Nekoma, Cavalier County, ND

  6. 40 CFR 265.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...

  7. 40 CFR 265.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...

  8. 40 CFR 265.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...

  9. 40 CFR 265.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...

  10. Modelling surface-water depression storage in a Prairie Pothole Region

    USGS Publications Warehouse

    Hay, Lauren E.; Norton, Parker A.; Viger, Roland; Markstrom, Steven; Regan, R. Steven; Vanderhoof, Melanie

    2018-01-01

    In this study, the Precipitation-Runoff Modelling System (PRMS) was used to simulate changes in surface-water depression storage in the 1,126-km2 Upper Pipestem Creek basin located within the Prairie Pothole Region of North Dakota, USA. The Prairie Pothole Region is characterized by millions of small water bodies (or surface-water depressions) that provide numerous ecosystem services and are considered an important contribution to the hydrologic cycle. The Upper Pipestem PRMS model was extracted from the U.S. Geological Survey's (USGS) National Hydrologic Model (NHM), developed to support consistent hydrologic modelling across the conterminous United States. The Geospatial Fabric database, created for the USGS NHM, contains hydrologic model parameter values derived from datasets that characterize the physical features of the entire conterminous United States for 109,951 hydrologic response units. Each hydrologic response unit in the Geospatial Fabric was parameterized using aggregated surface-water depression area derived from the National Hydrography Dataset Plus, an integrated suite of application-ready geospatial datasets. This paper presents a calibration strategy for the Upper Pipestem PRMS model that uses normalized lake elevation measurements to calibrate the parameters influencing simulated fractional surface-water depression storage. Results indicate that inclusion of measurements that give an indication of the change in surface-water depression storage in the calibration procedure resulted in accurate changes in surface-water depression storage in the water balance. Regionalized parameterization of the USGS NHM will require a proxy for change in surface-storage to accurately parameterize surface-water depression storage within the USGS NHM.

  11. Benchmarking organic mixed conductors for transistors.

    PubMed

    Inal, Sahika; Malliaras, George G; Rivnay, Jonathan

    2017-11-24

    Organic mixed conductors have garnered significant attention in applications from bioelectronics to energy storage/generation. Their implementation in organic transistors has led to enhanced biosensing, neuromorphic function, and specialized circuits. While a narrow class of conducting polymers continues to excel in these new applications, materials design efforts have accelerated as researchers target new functionality, processability, and improved performance/stability. Materials for organic electrochemical transistors (OECTs) require both efficient electronic transport and facile ion injection in order to sustain high capacity. In this work, we show that the product of the electronic mobility and volumetric charge storage capacity (µC*) is the materials/system figure of merit; we use this framework to benchmark and compare the steady-state OECT performance of ten previously reported materials. This product can be independently verified and decoupled to guide materials design and processing. OECTs can therefore be used as a tool for understanding and designing new organic mixed conductors.

  12. Storage and retrieval of light pulse in coupled quantum wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jibing, E-mail: liu0328@foxmail.com; Liu, Na; Shan, Chuanjia

    In this paper, we propose an effective scheme to create a frequency entangled states based on bound-to-bound inter-subband transitions in an asymmetric three-coupled quantum well structure. A four-subband cascade configuration quantum well structure is illuminated with a pulsed probe field and two continuous wave control laser fields to generate a mixing field. By properly adjusting the frequency detunings and the intensity of coupling fields, the conversion efficiency can reach 100%. A maximum entangled state can be achieved by selecting a proper length of the sample. We also numerically investigate the propagation dynamics of the probe pulse and mixing pulse, themore » results show that two frequency components are able to exchange energy through a four-wave mixing process. Moreover, by considering special coupling fields, the storage and retrieval of the probe pulse is also numerically simulated.« less

  13. Method of encapsulating solid radioactive waste material for storage

    DOEpatents

    Bunnell, Lee Roy; Bates, J. Lambert

    1976-01-01

    High-level radioactive wastes are encapsulated in vitreous carbon for long-term storage by mixing the wastes as finely divided solids with a suitable resin, formed into an appropriate shape and cured. The cured resin is carbonized by heating under a vacuum to form vitreous carbon. The vitreous carbon shapes may be further protected for storage by encasement in a canister containing a low melting temperature matrix material such as aluminum to increase impact resistance and improve heat dissipation.

  14. Method for storage of solid waste

    DOEpatents

    Mecham, William J.

    1976-01-01

    Metal canisters for long-term storage of calcined highlevel radioactive wastes can be made self-sealing against a breach in the canister wall by the addition of powdered cement to the canister with the calcine before it is sealed for storage. Any breach in the canister wall will permit entry of water which will mix with the cement and harden to form a concrete patch, thus sealing the opening in the wall of the canister and preventing the release of radioactive material to the cooling water or atmosphere.

  15. Space Station thermal storage/refrigeration system research and development

    NASA Astrophysics Data System (ADS)

    Dean, W. G.; Karu, Z. S.

    1993-02-01

    Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).

  16. Space Station thermal storage/refrigeration system research and development

    NASA Technical Reports Server (NTRS)

    Dean, W. G.; Karu, Z. S.

    1993-01-01

    Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).

  17. Velocity Model for CO2 Sequestration in the Southeastern United States Atlantic Continental Margin

    NASA Astrophysics Data System (ADS)

    Ollmann, J.; Knapp, C. C.; Almutairi, K.; Almayahi, D.; Knapp, J. H.

    2017-12-01

    The sequestration of carbon dioxide (CO2) is emerging as a major player in offsetting anthropogenic greenhouse gas emissions. With 40% of the United States' anthropogenic CO2 emissions originating in the southeast, characterizing potential CO2 sequestration sites is vital to reducing the United States' emissions. The goal of this research project, funded by the Department of Energy (DOE), is to estimate the CO2 storage potential for the Southeastern United States Atlantic Continental Margin. Previous studies find storage potential in the Atlantic continental margin. Up to 16 Gt and 175 Gt of storage potential are estimated for the Upper Cretaceous and Lower Cretaceous formations, respectively. Considering 2.12 Mt of CO2 are emitted per year by the United States, substantial storage potential is present in the Southeastern United States Atlantic Continental Margin. In order to produce a time-depth relationship, a velocity model must be constructed. This velocity model is created using previously collected seismic reflection, refraction, and well data in the study area. Seismic reflection horizons were extrapolated using well log data from the COST GE-1 well. An interpolated seismic section was created using these seismic horizons. A velocity model will be made using P-wave velocities from seismic reflection data. Once the time-depth conversion is complete, the depths of stratigraphic units in the seismic refraction data will be compared to the newly assigned depths of the seismic horizons. With a lack of well control in the study area, the addition of stratigraphic unit depths from 171 seismic refraction recording stations provides adequate data to tie to the depths of picked seismic horizons. Using this velocity model, the seismic reflection data can be presented in depth in order to estimate the thickness and storage potential of CO2 reservoirs in the Southeastern United States Atlantic Continental Margin.

  18. Toroidal constant-tension superconducting magnetic energy storage units

    DOEpatents

    Herring, J. Stephen

    1992-01-01

    A superconducting magnetic energy storage unit is provided in which the magnet is wound in a toroidal fashion such that the magnetic field produced is contained only within the bore of the magnet, and thus producing a very low external field. The superconducting magnet includes a coolant channel disposed through the wire. The bore of the magnet comprises a storage volume in which cryogenic coolant is stored, and this volume supplies the coolant to be delivered to the coolant channel in the magnet.

  19. Toroidal constant-tension superconducting magnetic energy storage units

    DOEpatents

    Herring, J.S.

    1992-11-03

    A superconducting magnetic energy storage unit is provided in which the magnet is wound in a toroidal fashion such that the magnetic field produced is contained only within the bore of the magnet, and thus producing a very low external field. The superconducting magnet includes a coolant channel disposed through the wire. The bore of the magnet comprises a storage volume in which cryogenic coolant is stored, and this volume supplies the coolant to be delivered to the coolant channel in the magnet. 6 figs.

  20. Identifying Potential Markets for Behind-the-Meter Battery Energy Storage: A Survey of U.S. Demand Charges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaren, Joyce A; Gagnon, Pieter J; Mullendore, Seth

    This paper presents the first publicly available comprehensive survey of the magnitude of demand charges for commercial customers across the United States -- a key predictor of the financial performance of behind-the-meter battery storage systems. Notably, the analysis estimates that there are nearly 5 million commercial customers in the United States who can subscribe to retail electricity tariffs that have demand charges in excess of $15 per kilowatt (kW), over a quarter of the 18 million commercial customers in total in the United States. While the economic viability of installing battery energy storage must be determined on a case-by-case basis,more » high demand charges are often cited as a critical factor in battery project economics. Increasing use of demand charges in utility tariffs and anticipated future declines in storage costs will only serve to unlock additional markets and strengthen existing ones.« less

  1. Complementing hydropower with PV and wind: optimal energy mix in a fully renewable Switzerland

    NASA Astrophysics Data System (ADS)

    Dujardin, Jérôme; Kahl, Annelen; Kruyt, Bert; Lehning, Michael

    2017-04-01

    Like several other countries, Switzerland plans to phase out its nuclear power production and will replace most or all of it by renewables. Switzerland has the chance to benefit from a large hydropower potential and has already exploited almost all of it. Currently about 60% of the Swiss electricity consumption is covered by hydropower, which will eventually leave a gap of about 40% to the other renewables mainly composed of photovoltaics (PV) and wind. With its high flexibility, storage hydropower will play a major role in the future energy mix, providing valuable power and energy balance. Our work focuses on the interplay between PV, wind and storage hydropower, to analyze the dynamics of this complex system and to identify the best PV-wind mixing ratio. Given the current electricity consumption and the currently installed pumping capacity of the storage hydropower plants, it appears that the Swiss hydropower system can completely alleviate the intermittency of PV and wind. However, some seasonal mismatch between production and demand will remain, but we show that oversizing the production from PV and wind or enlarging the reservoir capacity can be a solution to keep it to an acceptable level or even eliminate it. We found that PV, wind and hydropower performs the best together when the share of PV in the solar - wind mix is between 20 and 60%. These findings are quantitatively specific for Switzerland but qualitatively transferable to similar mountainous environments with abundant hydropower resources.

  2. 40 CFR Appendix E to Part 63 - Monitoring Procedure for Nonthoroughly Mixed Open Biological Treatment Systems at Kraft Pulp...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... II. Definitions Biological treatment unit = wastewater treatment unit designed and operated to... last zone in the series and ending with the first zone. B. Data Collection Requirements This method is based upon modeling the nonthoroughly mixed open biological treatment unit as a series of well-mixed...

  3. The Need for Integrating the Back End of the Nuclear Fuel Cycle in the United States of America

    DOE PAGES

    Bonano, Evaristo J.; Kalinina, Elena A.; Swift, Peter N.

    2018-02-26

    Current practice for commercial spent nuclear fuel management in the United States of America (US) includes storage of spent fuel in both pools and dry storage cask systems at nuclear power plants. Most storage pools are filled to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler fuel from pools into dry storage. In the absence of a repository that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 134,000 metric tons of spent fuel in dry storage by mid-centurymore » when the last plants in the current reactor fleet are decommissioned. Current designs for storage systems rely on large dual-purpose (storage and transportation) canisters that are not optimized for disposal. Various options exist in the US for improving integration of management practices across the entire back end of the nuclear fuel cycle.« less

  4. The Need for Integrating the Back End of the Nuclear Fuel Cycle in the United States of America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonano, Evaristo J.; Kalinina, Elena A.; Swift, Peter N.

    Current practice for commercial spent nuclear fuel management in the United States of America (US) includes storage of spent fuel in both pools and dry storage cask systems at nuclear power plants. Most storage pools are filled to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler fuel from pools into dry storage. In the absence of a repository that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 134,000 metric tons of spent fuel in dry storage by mid-centurymore » when the last plants in the current reactor fleet are decommissioned. Current designs for storage systems rely on large dual-purpose (storage and transportation) canisters that are not optimized for disposal. Various options exist in the US for improving integration of management practices across the entire back end of the nuclear fuel cycle.« less

  5. Onboard System Evaluation of Rotors Vibration, Engines (OBSERVE) monitoring System

    DTIC Science & Technology

    1992-07-01

    consists of a Data Acquisiiton Unit (DAU), Control and Display Unit ( CADU ), Universal Tracking Devices (UTD), Remote Cockpit Display (RCD) and a PC...and Display Unit ( CADU ) - The CADU provides data storage and a graphical user interface neccesary to display both the measured data and diagnostic...information. The CADU has an interface to a Credit Card Memory (CCM) which operates similar to a disk drive, allowing the storage of data and programs. The

  6. Storage of Medical Unit Prepositioned War Reserve Materiel

    DTIC Science & Technology

    1978-01-01

    PROJECT REPORT JANUARY 1978 DARCOM 5-77 STORAGE OF MEDICAL UNIT PREPOSITIONED m WAR RESERVE MATERIEL DTIC I 1is dcurtent hais lbe-i approved J JU N...ERIZATION CENTER 8030 TOITHANNA ARMY BEPOT 8030 1 OITNANNA, PENNSYLVANIA 11466 81 6 03 048 ABSTRACT .Army Medical Department (AMEDD) war reserve stocks are...presently commingled with mission stocks throughout the world . In case of mobilization, these stocks must be selected, assembled into units, and

  7. Progress in preliminary studies at Ottana Solar Facility

    NASA Astrophysics Data System (ADS)

    Demontis, V.; Camerada, M.; Cau, G.; Cocco, D.; Damiano, A.; Melis, T.; Musio, M.

    2016-05-01

    The fast increasing share of distributed generation from non-programmable renewable energy sources, such as the strong penetration of photovoltaic technology in the distribution networks, has generated several problems for the management and security of the whole power grid. In order to meet the challenge of a significant share of solar energy in the electricity mix, several actions aimed at increasing the grid flexibility and its hosting capacity, as well as at improving the generation programmability, need to be investigated. This paper focuses on the ongoing preliminary studies at the Ottana Solar Facility, a new experimental power plant located in Sardinia (Italy) currently under construction, which will offer the possibility to progress in the study of solar plants integration in the power grid. The facility integrates a concentrating solar power (CSP) plant, including a thermal energy storage system and an organic Rankine cycle (ORC) unit, with a concentrating photovoltaic (CPV) plant and an electrical energy storage system. The facility has the main goal to assess in real operating conditions the small scale concentrating solar power technology and to study the integration of the two technologies and the storage systems to produce programmable and controllable power profiles. A model for the CSP plant yield was developed to assess different operational strategies that significantly influence the plant yearly yield and its global economic effectiveness. In particular, precise assumptions for the ORC module start-up operation behavior, based on discussions with the manufacturers and technical datasheets, will be described. Finally, the results of the analysis of the: "solar driven", "weather forecasts" and "combined storage state of charge (SOC)/ weather forecasts" operational strategies will be presented.

  8. 1999 Report on Hanford Site land disposal restriction for mixed waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BLACK, D.G.

    This report was submitted to meet the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-26-011. This milestone requires the preparation of an annual report that covers characterization, treatment, storage, minimization, and other aspects of managing land-disposal-restricted mixed waste at the Hanford Facility.

  9. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects

    PubMed Central

    Kriebardis, Anastasios G.; Antonelou, Marianna H.; Georgatzakou, Hara T.; Tzounakas, Vassilis L.; Stamoulis, Konstantinos E.; Papassideri, Issidora S.

    2016-01-01

    Background Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Materials and methods Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors’ haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Results Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. Discussion The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles. PMID:27136430

  10. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.

    PubMed

    Kriebardis, Anastasios G; Antonelou, Marianna H; Georgatzakou, Hara T; Tzounakas, Vassilis L; Stamoulis, Konstantinos E; Papassideri, Issidora S

    2016-05-01

    Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors' haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles.

  11. 40 CFR 63.1360 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...

  12. 40 CFR 63.1360 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...

  13. 40 CFR 63.1360 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...

  14. 40 CFR 63.1360 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...

  15. 76 FR 70957 - Foreign-Trade Zone 277-Western Maricopa County, AZ; Application for Manufacturing Authority, Sub...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ..., and wine storage units for export and the domestic market. Components and materials sourced from... entry procedures that applies to refrigerators, freezers, and wine storage units (duty rate--free) for... realize logistical benefits through the use of weekly customs entry procedures. Customs duties also could...

  16. Duration of storage influences the hemoglobin rising effect of red blood cells in patients undergoing major abdominal surgery.

    PubMed

    Hunsicker, Oliver; Hessler, Katarina; Krannich, Alexander; Boemke, Willehad; Braicu, Ioana; Sehouli, Jalid; Meyer, Oliver; Pruß, Axel; Spies, Claudia; Feldheiser, Aarne

    2018-04-17

    After transfusion of senescent red blood cells (RBCs) a considerable fraction is rapidly cleared from the recipients' circulation. Thus, transfusion of senescent RBCs may be less effective in terms of increasing hemoglobin concentration (cHb) after transfusion. Data were retrospectively obtained in patients who underwent major abdominal surgery between 2006 and 2012. Patients were eligible if they received RBCs during surgery and had at least two arterial blood gas analyses performed. The primary endpoint was the increase of recipients' cHb related to the transfusion of 1 unit of RBCs with respect to different storage periods. Four storage periods were defined according to the distribution of RBC storage of the study population. General estimating equation was used for calculation of the primary endpoint and to adjust for confounding variables. A total of 598 arterial blood gas samples from 120 patients, receiving 429 RBC units, were analyzed. Mean (±SD) RBC storage was 21 (±9) days. RBC storage duration and the increase in recipients' cHb were inversely and gradually related; that is, the older the RBCs, the lower the increase in the recipients' cHb after transfusion (storage < 12 days, ΔcHb per unit RBCs +0.82 [95% confidence interval, 0.42-1.21] g/dL, p < 0.01; storage 12-20 days, +0.66 [0.46-0.86] g/dL, p < 0.01; storage 21-29 days, +0.56 [0.33-0.79] g/dL, p < 0.01; storage ≥30 days, +0.39 [0.07 to 0.71] g/dL, p = 0.02). Transfusion of senescent RBCs increased cHb less effectively than transfusion of fresher RBCs. © 2018 AABB.

  17. Impact of blood manufacturing and donor characteristics on membrane water permeability and in vitro quality parameters during hypothermic storage of red blood cells.

    PubMed

    Alshalani, Abdulrahman; Howell, Anita; Acker, Jason P

    2018-02-01

    Several factors have been proposed to influence the red blood cell storage lesion including storage duration, blood component manufacturing methodology, and donor characteristics [1,18]. The objectives of this study were to determine the impact of manufacturing method and donor characteristics on water permeability and membrane quality parameters. Red blood cell units were obtained from volunteer blood donors and grouped according to the manufacturing method and donor characteristics of sex and age. Membrane water permeability and membrane quality parameters, including deformability, hemolysis, osmotic fragility, hematologic indices, supernatant potassium, and supernatant sodium, were determined on day 5 ± 2, day 21, and day 42. Regression analysis was applied to evaluate the contribution of storage duration, manufacturing method, and donor characteristics on storage lesion. This study found that units processed using a whole blood filtration manufacturing method exhibited significantly higher membrane water permeability throughout storage compared to units manufactured using red cell filtration. Additionally, significant differences in hemolysis, supernatant potassium, and supernatant sodium were seen between manufacturing methods, however there were no significance differences between donor age and sex groups. Findings of this study suggest that the membrane-related storage lesion is initiated prior to the first day of storage with contributions by both blood manufacturing process and donor variability. The findings of this work highlight the importance of characterizing membrane water permeability during storage as it can be a predictor of the biophysical and chemical changes that affect the quality of stored red blood cells during hypothermic storage. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Hydrological analysis of single and dual storage systems for stormwater harvesting.

    PubMed

    Brodie, I M

    2008-01-01

    As stormwater flows are intermittent, the requirement to store urban runoff is important to the design of a stormwater re-use scheme. In many urban areas, the space available to provide storage is limited and thus the need to optimise the storage volume becomes critical. This paper will highlight the advantages and disadvantages of two different approaches of providing storage: 1) a single shallow storage (0.5 m depth) in which stormwater capture and a balanced release to supply users is provided by the one unit; and 2) a dual system in which the functions of stormwater capture and supply release are provided by two separate deeper storage units (2 m depth). The comparison between the two strategies is supported by water balance modelling assessing the supply reliability and storage volume requirements for both options. Above a critical volumetric capacity, the supply yield of a dual storage system is higher than that from a single storage of equal volume mainly because of a smaller assumed footprint. The single storage exhibited greater evaporation loss and is more susceptible to algae blooms due to long water residence times. Results of the comparison provide guidance to the design of more efficient storages associated with stormwater harvesting systems. Copyright IWA Publishing 2008.

  19. 40 CFR 63.8985 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... production facility includes all HCl storage tanks that contain liquid HCl product that is produced in the... service used to transfer liquid HCl product from the HCl production unit to the HCl storage tanks and/or... site via pipeline. (2) Storage tanks that are dedicated feedstock tanks for another process and storage...

  20. 32 CFR 855.16 - Parking and storage.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...

  1. 32 CFR 855.16 - Parking and storage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...

  2. 32 CFR 855.16 - Parking and storage.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...

  3. Blood banking-induced alteration of red blood cell oxygen release ability

    PubMed Central

    Li, Yaojin; Xiong, Yanlian; Wang, Ruofeng; Tang, Fuzhou; Wang, Xiang

    2016-01-01

    Background Current blood banking procedures may not fully preserve red blood cell (RBC) function during storage, contributing to the decrease of RBC oxygen release ability. This study was undertaken to evaluate the impact of routine cold storage on RBC oxygen release ability. Materials and methods RBC units were collected from healthy donors and each unit was split into two parts (whole blood and suspended RBC) to exclude possible donor variability. Oxygen dissociation measurements were performed on blood units stored at 4 °C during a 5-week period. 2,3-diphosphoglycerate levels and fluorescent micrographs of erythrocyte band 3 were also analysed. Results P50 and oxygen release capacity decreased rapidly during the first 3 weeks, and then did not change significantly. In contrast, the kinetic properties (PO2-t curve and T*50) of oxygen release changed slowly during the first 3 weeks of storage, but then decreased significantly in the last 2 weeks. 2,3-diphosphoglycerate decreased quickly during the first 3 weeks of storage to almost undetectable levels. Band 3 aggregated significantly during the last 2 weeks of storage. Discussion RBC oxygen release ability appears to be sensitive to routine cold storage. The thermodynamic characteristics of RBC oxygen release ability changed mainly in the first 3 weeks of storage, due to the decrease of 2,3-diphosphoglycerate, whereas the kinetic characteristics of RBC oxygen release ability decreased significantly at the end of storage, probably affected by alterations of band 3. PMID:26674824

  4. Blood banking-induced alteration of red blood cell oxygen release ability.

    PubMed

    Li, Yaojin; Xiong, Yanlian; Wang, Ruofeng; Tang, Fuzhou; Wang, Xiang

    2016-05-01

    Current blood banking procedures may not fully preserve red blood cell (RBC) function during storage, contributing to the decrease of RBC oxygen release ability. This study was undertaken to evaluate the impact of routine cold storage on RBC oxygen release ability. RBC units were collected from healthy donors and each unit was split into two parts (whole blood and suspended RBC) to exclude possible donor variability. Oxygen dissociation measurements were performed on blood units stored at 4 °C during a 5-week period. 2,3-diphosphoglycerate levels and fluorescent micrographs of erythrocyte band 3 were also analysed. P50 and oxygen release capacity decreased rapidly during the first 3 weeks, and then did not change significantly. In contrast, the kinetic properties (PO2-t curve and T*50) of oxygen release changed slowly during the first 3 weeks of storage, but then decreased significantly in the last 2 weeks. 2,3-diphosphoglycerate decreased quickly during the first 3 weeks of storage to almost undetectable levels. Band 3 aggregated significantly during the last 2 weeks of storage. RBC oxygen release ability appears to be sensitive to routine cold storage. The thermodynamic characteristics of RBC oxygen release ability changed mainly in the first 3 weeks of storage, due to the decrease of 2,3-diphosphoglycerate, whereas the kinetic characteristics of RBC oxygen release ability decreased significantly at the end of storage, probably affected by alterations of band 3.

  5. High temperature thermal energy storage in steel and sand

    NASA Technical Reports Server (NTRS)

    Turner, R. H.

    1979-01-01

    The technical and economic potential for high temperature (343 C, 650 F) thermal energy storage in hollow steel ingots, pipes embedded in concrete, and for pipes buried in sand was evaluated. Because it was determined that concrete would separate from pipes due to thermal stresses, concrete was replaced by sand, which is free from thermal stresses. Variations of the steel ingot concept were not cost effective compared to the sand-pipe approach, therefore, the sand-pipe thermal storage unit (TSU) was evaluated in depth to assess the approximate tube spacing requirements consistent with different system performance characteristics and also attendant system costs. For large TSUs which do not require fast response times, the sand-pipe approach offers attractive possibilities. A pipe diameter about 9 cm (3.5 in) and pipe spacing of approximately 25 cm (10 in), with sand filling the interspaces, appears appropriate. Such a TSU system designed for 8 hours charge/discharge cycle has an energy unit storage cost (CE) of $2.63/kWhr-t and a power unit storage cost (Cp) of $42/kW-t (in 1977 dollars).

  6. Using Emergent and Internal Catchment Data to Elucidate the Influence of Landscape Structure and Storage State on Hydrologic Response in a Piedmont Watershed

    NASA Astrophysics Data System (ADS)

    Putnam, S. M.; Harman, C. J.

    2017-12-01

    Many studies have sought to unravel the influence of landscape structure and catchment state on the quantity and composition of water at the catchment outlet. These studies run into issues of equifinality where multiple conceptualizations of flow pathways or storage states cannot be discriminated against on the basis of the quantity and composition of water alone. Here we aim to parse out the influence of landscape structure, flow pathways, and storage on both the observed catchment hydrograph and chemograph, using hydrometric and water isotope data collected from multiple locations within Pond Branch, a 37-hectare Piedmont catchment of the eastern US. This data is used to infer the quantity and age distribution of water stored and released by individual hydrogeomorphic units, and the catchment as a whole, in order to test hypotheses relating landscape structure, flow pathways, and catchment storage to the hydrograph and chemograph. Initial hypotheses relating internal catchment properties or processes to the hydrograph or chemograph are formed at the catchment scale. Data from Pond Branch include spring and catchment discharge measurements, well water levels, and soil moisture, as well as three years of high frequency precipitation and surface water stable water isotope data. The catchment hydrograph is deconstructed using hydrograph separation and the quantity of water associated with each time-scale of response is compared to the quantity of discharge that could be produced from hillslope and riparian hydrogeomorphic units. Storage is estimated for each hydrogeomorphic unit as well as the vadose zone, in order to construct a continuous time series of total storage, broken down by landscape unit. Rank StorAge Selection (rSAS) functions are parameterized for each hydrogeomorphic unit as well as the catchment as a whole, and the relative importance of changing proportions of discharge from each unit as well as storage in controlling the variability in the catchment chemograph is explored. The results suggest that the quantity of quickflow can be accounted for by direct precipitation onto < 5.2% of the catchment area, representing a zero-order swale plus the riparian area. rSAS modeling suggests that quickflow is largely composed of pre-event, stored water, generated through a process such as groundwater ridging.

  7. A practical approach for calculating the settlement and storage capacity of landfills based on the space and time discretization of the landfilling process.

    PubMed

    Gao, Wu; Xu, Wenjie; Bian, Xuecheng; Chen, Yunmin

    2017-11-01

    The settlement of any position of the municipal solid waste (MSW) body during the landfilling process and after its closure has effects on the integrity of the internal structure and storage capacity of the landfill. This paper proposes a practical approach for calculating the settlement and storage capacity of landfills based on the space and time discretization of the landfilling process. The MSW body in the landfill was divided into independent column units, and the filling process of each column unit was determined by a simplified complete landfilling process. The settlement of a position in the landfill was calculated with the compression of each MSW layer in every column unit. Then, the simultaneous settlement of all the column units was integrated to obtain the settlement of the landfill and storage capacity of all the column units; this allowed to obtain the storage capacity of the landfill based on the layer-wise summation method. When the compression of each MSW layer was calculated, the effects of the fluctuation of the main leachate level and variation in the unit weight of the MSW on the overburdened effective stress were taken into consideration by introducing the main leachate level's proportion and the unit weight and buried depth curve. This approach is especially significant for MSW with a high kitchen waste content and landfills in developing countries. The stress-biodegradation compression model was used to calculate the compression of each MSW layer. A software program, Settlement and Storage Capacity Calculation System for Landfills, was developed by integrating the space and time discretization of the landfilling process and the settlement and storage capacity algorithms. The landfilling process of the phase IV of Shanghai Laogang Landfill was simulated using this software. The maximum geometric volume of the landfill error between the calculated and measured values is only 2.02%, and the accumulated filling weight error between the calculated value and measured value is less than 5%. These results show that this approach is practical for satisfactorily and reliably calculating the settlement and storage capacity. In addition, the development of the elevation lines in the landfill sections created with the software demonstrates that the optimization of the design of the structures should be based on the settlement of the landfill. Since this practical approach can reasonably calculate the storage capacity of landfills and efficiently provide the development of the settlement of each landfilling stage, it can be used for the optimizations of landfilling schemes and structural designs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Carbon storage in old-growth forests of the Mid-Atlantic: toward better understanding the eastern forest carbon sink.

    PubMed

    McGarvey, Jennifer C; Thompson, Jonathan R; Epstein, Howard E; Shugart, Herman H

    2015-02-01

    Few old-growth stands remain in the matrix of secondary forests that dominates the eastern North American landscape. These remnant stands offer insight on the potential carbon (C) storage capacity of now-recovering secondary forests. We surveyed the remaining old-growth forests on sites characteristic of the general Mid-Atlantic United States and estimated the size of multiple components of forest C storage. Within and between old-growth stands, variability in C density is high and related to overstory tree species composition. The sites contain 219 ± 46 Mg C/ha (mean ± SD), including live and dead aboveground biomass, leaf litter, and the soil O horizon, with over 20% stored in downed wood and snags. Stands dominated by tulip poplar (Liriodendron tulipifera) store the most live biomass, while the mixed oak (Quercus spp.) stands overall store more dead wood. Total C density is 30% higher (154 Mg C/ha), and dead wood C density is 1800% higher (46 Mg C/ha) in the old-growth forests than in the surrounding younger forests (120 and 5 Mg C/ha, respectively). The high density of dead wood in old growth relative to secondary forests reflects a stark difference in historical land use and, possibly, the legacy of the local disturbance (e.g., disease) history. Our results demonstrate the potential for dead wood to maintain the sink capacity of secondary forests for many decades to come.

  9. Reticulocyte count in red-blood-cell units stored in AS-1.

    PubMed

    Urbina, A; Palomino, F

    2013-05-01

    Previous data that showed maintenance of reticulocyte percentage in whole blood stored in CPDA-1 have led to the assumption that reticulocyte maturation becomes arrested during refrigerated storage. However, reticulocyte behaviour in red-blood-cell units stored in additive solutions has not yet been studied. This study was thus aimed at determining reticulocyte count and reticulocyte subtypes in red-blood-cells units stored in AS-1. Reticulocyte percentage and subtypes were determined by flow cytometry with thiazole orange in six red-blood-cells units stored in AS-1. Reticulocyte count was 26.8 ± 4.6 × 10(9) /l at week 0.5 and 8.2 ± 2.9 × 10(9) /l at week 6. Total haemolysis during storage was 0.19 ± 0.08%. High-fluorescence reticulocytes were 2.0 ± 3.2 × 10(9) /l at week 0.5 and decreased by weeks 2, 4 and 6. Low-fluorescence reticulocytes were 22.1 ± 3.1 × 10(9) /l at week 0.5 and decreased by weeks 4 and 6. A significant decrease in reticulocytes occurred during red-blood-cells units' storage in AS-1. Even if it were assumed that all of haemolysed cells during storage were reticulocytes, there are a number of them whose disappearance cannot be explained by this mechanism. Changes observed in reticulocyte subtypes suggest that they mature during storage. © 2013 The Author(s) Vox Sanguinis © 2013 International Society of Blood Transfusion.

  10. Systems and methods for distributing power using photovoltaic resources and a shifting battery system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mammoli, Andrea A.; Lavrova, Olga; Arellano, Brian

    The present invention is an apparatus and method for delivering energy using a renewable resource. The method includes providing a photovoltaic energy source and applying energy storage to the photovoltaic energy source via a battery storage unit. The energy output from the photovoltaic energy source and the battery system is controlled using a battery control system. The battery control system predicts peak load, develops a schedule that includes when to begin discharging power and when to stop discharging power, shifts power to the battery storage unit when excess power is available, and prioritizes the functionality of the battery storage unitmore » and the photovoltaic energy source.« less

  11. In vitro storage characteristics of platelet concentrates suspended in 70% SSP+(TM) additive solution versus plasma over a 14-day storage period.

    PubMed

    Saunders, C; Rowe, G; Wilkins, K; Holme, S; Collins, P

    2011-08-01

    The non-paired two-arm study compared the in vitro storage characteristics of platelets suspended as concentrates in either 100% plasma or a mixture of additive solution (SSP+™, MacoPharma, Mouveaux, France) and autologous plasma in a 70:30 ratio over a 14-day storage period. The buffy coat-derived pooled platelet concentrates were sampled on days 1, 2, 3, 6, 8, 10 and 14 and tests performed to determine platelet morphology, function, metabolism, activation and apoptosis-like activity. Swirling remained strong (score=3) in SSP+™, whilst scores of 1 and 0 were noted for plasma units by end of storage. In contrast to units in plasma, pH levels remained above seven in SSP+™ units, increasing after day 10. Percent positive expression of CD62P was similar in both groups on day 1 (median of 54% and 56% for plasma (n=13) and SSP+™ (n=12), respectively), with SSP+™ units showing a more moderate increase in activation after day 10. A progressive decrease in mitochondrial membrane potential was evident in both groups from day 1, whilst annexin V binding was relatively stable from days 1 to 3, with median values remaining below 6%. Subsequent to this, the percentage of platelets binding annexin V increased to approximately 30% by day 14. Platelets suspended in a medium of 70:30 SSP+™ to plasma ratio performed at least as well as platelets in 100% autologous plasma for up to 10 days of storage. Further, results are suggestive of an apoptosis-like process being involved in the platelet storage lesion. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.

  12. A comparative study of kinetic and connectionist modeling for shelf-life prediction of Basundi mix.

    PubMed

    Ruhil, A P; Singh, R R B; Jain, D K; Patel, A A; Patil, G R

    2011-04-01

    A ready-to-reconstitute formulation of Basundi, a popular Indian dairy dessert was subjected to storage at various temperatures (10, 25 and 40 °C) and deteriorative changes in the Basundi mix were monitored using quality indices like pH, hydroxyl methyl furfural (HMF), bulk density (BD) and insolubility index (II). The multiple regression equations and the Arrhenius functions that describe the parameters' dependence on temperature for the four physico-chemical parameters were integrated to develop mathematical models for predicting sensory quality of Basundi mix. Connectionist model using multilayer feed forward neural network with back propagation algorithm was also developed for predicting the storage life of the product employing artificial neural network (ANN) tool box of MATLAB software. The quality indices served as the input parameters whereas the output parameters were the sensorily evaluated flavour and total sensory score. A total of 140 observations were used and the prediction performance was judged on the basis of per cent root mean square error. The results obtained from the two approaches were compared. Relatively lower magnitudes of percent root mean square error for both the sensory parameters indicated that the connectionist models were better fitted than kinetic models for predicting storage life.

  13. Synergistic effect of high hydrostatic pressure and natural antimicrobials on inactivation kinetics of Bacillus cereus in a liquid whole egg and skim milk mixed beverage.

    PubMed

    Pina-Pérez, Maria Consuelo; Silva-Angulo, Angela B; Muguerza-Marquínez, Begoña; Aliaga, D Rodrigo; López, Antonio Martínez

    2009-01-01

    An in-depth study was conducted in order to extend the storage life of a liquid whole egg-skim milk (LWE-SM) mixed beverage to enhance its safety and the safety of related beverages. Bacillus cereus vegetative cells (1 x 10(8) colony-forming units [CFU]/mL) were inoculated in LWE-SM beverages with or without natural antimicrobial supplements: flavonol rich-cocoa powder (cocoanOX 12%, CCX) (700 ppm), vanillin (700 ppm), anise (700 ppm), and cinnamon (700 ppm). B. cereus cells were maintained at 10 degrees C for 10 days in the different beverages to test the bacteriostatic or inhibitory effect of the aforementioned ingredients. Beverages were treated with high hydrostatic pressure (HHP) technology and stored at 10 degrees C for 15 days after treatment. All natural antimicrobials reduced the micro(max) values and increased the lag phase time of B. cereus, and Gompertz growth curves showed different inhibitory effects depending on the substance. The maximum inhibitory effect (1.330 log cycle reduction) was achieved in LWE-SM-cinnamon-supplemented beverage. The maximum inactivation achieved by HHP in LWE-SM beverage was a reduction of around 3.89 +/- 0.25 log cycles at 300 MPa for 12 minutes. When supplemented beverages were treated under the same conditions, enhanced inactivation levels were achieved. This increased inactivation can be attributed to a synergistic effect when the LWE-SM was supplemented with flavonol-rich cocoa powder, cinnamon, and vanillin. The maximum synergistic effect was observed in LWE-SM-CCX-supplemented beverage. During the refrigerated storage of B. cereus HHP-treated cells in beverages to which antimicrobials had been added, the inhibitory effect was dependent on the previously applied pressure level.

  14. Inert matrix fuel neutronic, thermal-hydraulic, and transient behavior in a light water reactor

    NASA Astrophysics Data System (ADS)

    Carmack, W. J.; Todosow, M.; Meyer, M. K.; Pasamehmetoglu, K. O.

    2006-06-01

    Currently, commercial power reactors in the United States operate on a once-through or open cycle, with the spent nuclear fuel eventually destined for long-term storage in a geologic repository. Since the fissile and transuranic (TRU) elements in the spent nuclear fuel present a proliferation risk, limit the repository capacity, and are the major contributors to the long-term toxicity and dose from the repository, methods and systems are needed to reduce the amount of TRU that will eventually require long-term storage. An option to achieve a reduction in the amount, and modify the isotopic composition of TRU requiring geological disposal is 'burning' the TRU in commercial light water reactors (LWRs) and/or fast reactors. Fuel forms under consideration for TRU destruction in light water reactors (LWRs) include mixed-oxide (MOX), advanced mixed-oxide, and inert matrix fuels. Fertile-free inert matrix fuel (IMF) has been proposed for use in many forms and studied by several researchers. IMF offers several advantages relative to MOX, principally it provides a means for reducing the TRU in the fuel cycle by burning the fissile isotopes and transmuting the minor actinides while producing no new TRU elements from fertile isotopes. This paper will present and discuss the results of a four-bundle, neutronic, thermal-hydraulic, and transient analyses of proposed inert matrix materials in comparison with the results of similar analyses for reference UOX fuel bundles. The results of this work are to be used for screening purposes to identify the general feasibility of utilizing specific inert matrix fuel compositions in existing and future light water reactors. Compositions identified as feasible using the results of these analyses still require further detailed neutronic, thermal-hydraulic, and transient analysis study coupled with rigorous experimental testing and qualification.

  15. Gas hydrate cool storage system

    DOEpatents

    Ternes, Mark P.; Kedl, Robert J.

    1985-01-01

    This invention is a process for formation of a gas hydrate to be used as a cool storage medium using a refrigerant in water. Mixing of the immiscible refrigerant and water is effected by addition of a surfactant and agitation. The difficult problem of subcooling during the process is overcome by using the surfactant and agitation and performance of the process significantly improves and approaches ideal.

  16. Post-fire management regimes affect carbon sequestration and storage in a Sierra Nevada mixed conifer forest

    Treesearch

    Elizabeth M. Powers; John D. Marshall; Jianwei Zhang; Liang Wei

    2013-01-01

    Forests mitigate climate change by sequestering CO2 from the atmosphere and accumulating it in biomass storage pools. However, in dry conifer forests, fire occasionally returns large quantities of CO2 to the atmosphere. Both the total amount of carbon stored and its susceptibility to loss may be altered by post-fire land...

  17. Effects of inulin and oligofructose on the rheological characteristics and probiotic culture survival in low-fat probiotic ice cream.

    PubMed

    Akalin, A S; Erişir, D

    2008-05-01

    The effects of supplementation of oligofructose or inulin on the rheological characteristics and survival of Lactobacillus acidophilus La-5 and Bifidobacterium animalis Bb-12 in low-fat ice cream stored at -18 degrees C for 90 d were studied. Addition of oligofructose or inulin to ice cream mix significantly increased apparent viscosity and overrun and developed the melting properties in ice cream during storage (P < 0.05). However, the highest increase in firmness, the lowest change in melting properties, and the longest 1st dripping time were obtained in probiotic ice cream containing inulin (P < 0.05). Some textural properties have also improved especially by the end of storage. Freezing process caused a significant decrease in the viability of Lactobacillus acidophilus La-5 and Bifidobacterium animalis Bb-12 (P < 0.05). Oligofructose significantly improved the viability of L. acidophilus La-5 and B. animalis Bb-12 in ice cream mix (P < 0.05). Although the viable numbers for both bacteria decreased throughout the storage, the minimum level of 10(6) CFU/g was maintained for B. animalis Bb-12 in only ice cream with oligofructose during storage.

  18. Slotting optimization of automated storage and retrieval system (AS/RS) for efficient delivery of parts in an assembly shop using genetic algorithm: A case Study

    NASA Astrophysics Data System (ADS)

    Yue, L.; Guan, Z.; He, C.; Luo, D.; Saif, U.

    2017-06-01

    In recent years, the competitive pressure on manufacturing companies shifted them from mass production to mass customization to produce large variety of products. It is a great challenge for companies nowadays to produce customized mixed flow mode of production to meet customized demand on time. Due to large variety of products, the storage system to deliver variety of products to production lines influences on the timely production of variety of products, as investigated from by simulation study of an inefficient storage system of a real Company, in the current research. Therefore, current research proposed a slotting optimization model with mixed model sequence to assemble in consideration of the final flow lines to optimize whole automated storage and retrieval system (AS/RS) and distribution system in the case company. Current research is aimed to minimize vertical height of centre of gravity of AS/RS and total time spent for taking the materials out from the AS/RS simultaneously. Genetic algorithm is adopted to solve the proposed problem and computational result shows significant improvement in stability and efficiency of AS/RS as compared to the existing method used in the case company.

  19. Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System

    DOE PAGES

    Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias

    2018-01-03

    While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less

  20. Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias

    While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less

  1. Geology, ground-water hydrology, geochemistry, and ground-water simulation of the Beaumont and Banning Storage Units, San Gorgonio Pass area, Riverside County, California

    USGS Publications Warehouse

    Rewis, Diane L.; Christensen, Allen H.; Matti, Jonathan; Hevesi, Joseph A.; Nishikawa, Tracy; Martin, Peter

    2006-01-01

    Ground water has been the only source of potable water supply for residential, industrial, and agricultural users in the Beaumont and Banning storage units of the San Gorgonio Pass area, Riverside County, California. Ground-water levels in the Beaumont area have declined as much as 100 feet between the early 1920s and early 2000s, and numerous natural springs have stopped flowing. In 1961, the San Gorgonio Pass Water Agency (SGPWA) entered into a contract with the California State Department of Water Resources to receive 17,300 acre-feet per year of water to be delivered by the California State Water Project (SWP) to supplement natural recharge. Currently (2005), a pipeline is delivering SWP water into the area, and the SGPWA is artificially recharging the ground-water system using recharge ponds located along Little San Gorgonio Creek in Cherry Valley with the SWP water. In addition to artificial recharge, SGPWA is considering the direct delivery of SWP water for the irrigation of local golf courses and for agricultural supply in lieu of ground-water pumpage. To better understand the potential hydrologic effects of different water-management alternatives on ground-water levels and movement in the Beaumont and Banning storage units, existing geohydrologic and geochemical data were compiled, new data from a basin-wide ground-water level and water-quality monitoring network were collected, monitoring wells were installed near the Little San Gorgonio Creek recharge ponds, geohydrologic and geochemical analyses were completed, and a ground-water flow simulation model was developed. The San Gorgonio Pass area was divided into several storage units on the basis of mapped or inferred faults. This study addresses primarily the Beaumont and Banning storage units. The geologic units in the study area were generalized into crystalline basement rocks and sedimentary deposits. The younger sedimentary deposits and the surficial deposits are the main water-bearing deposits in the San Gorgonio Pass area. The water-bearing deposits were divided into three aquifers: (1) the perched aquifer, (2) the upper aquifer, and (3) the lower aquifer based on lithologic and downhole geophysical logs. Natural recharge in the San Gorgonio Pass area was estimated using INFILv3, a deterministic distributed- parameter precipitation-runoff model. The INFILv3 model simulated that the potential recharge of precipitation and runoff in the Beaumont and Banning storage units was about 3,710 acre-feet per year and that the potential recharge in 28 sub-drainage basins upstream of the storage units was about 6,180 acre-feet per year. The water supply for the Beaumont and Banning storage units is supplied by pumping ground water from wells in the Canyon (Edgar and Banning Canyons), Banning Bench, Beaumont, and Banning storage units. Total annual pumpage from the Beaumont and Banning storage units ranged from about 1,630 acre-feet in 1936 to about 20,000 acre-feet in 2003. Ground-water levels declined by as much as 100 feet in the Beaumont storage unit from 1926-2003 in response to ground-water pumping of about 450,160 acre-feet during this period. Since ground-water development began in the San Gorgonio Pass area, there have been several sources of artificial recharge to the basin including return flow from applied water on crops, golf courses, and landscape; septic-tank seepage; and infiltration of storm runoff diversions and imported water into recharge ponds. Return flow from applied water and septic-tank seepage was estimated to reach a maximum of about 8,100 acre-feet per year in 2003. Owing to the great depth of water in much of study area (in excess of 150 feet), the return flow and septic-tank seepage takes years to decades to reach the water table. Stable-isotope data indicate that the source of ground-water recharge was precipitation from storms passing through the San Gorgonio Pass as opposed to runoff from the higher altitudes of the San Bernar

  2. 78 FR 12050 - S. Martinez Livestock, Inc.; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-21

    ... traditional turbine-generator facility. The pumped storage facility would consist of: (1) A new upper... storage facility would be 86,430 megawatt hours. The turbine-generator facility would consist of: (1) an... turbine-generator unit. The estimated annual generation of the turbine generator unit would be 17,286...

  3. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Hoeschele, E. Weitzel, C. Backman

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit withmore » lower storage volume and reduced gas input requirements.« less

  4. Biochars impact on soil moisture storage in an Ultisol and two Aridisols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Novak, Jeffrey M.; Busscher, Warren J.; Watts, Don W.

    2012-05-31

    Biochar additions to soils can improve soil water storage capability, however, there is sparse information identifying feedstocks and pyrolysis conditions that maximize this improvement. Nine biochars were pyrolyzed from five feedstocks at two temperatures and their physical and chemical properties were characterized. Biochars were mixed at 2% wt w{sup -1} into a Norfolk loamy sand (Fine-loamy, kaolinitic, thermic Typic Kandiudult), a Declo silt loam (Coarse-loamy, mixed, superactive, mesic xeric Haplocalcid), or a Warden silt loam (Coarse-silty, mixed, superactive, mesic xeric Haplocambid). Untreated soils served as controls. Soils were laboratory incubated in pots for 127 days and were leached about everymore » 30 days with deionized water. Soil bulk densities were measured before each leaching event. For six days thereafter, pot holding capacities (PHC) for water were determined gravimetrically and were used as a surrogate for soil moisture contents. Water tension curves were also measured on the biochar treated and untreated Norfolk soil. Biochar surface area, surface tension, ash, C, and Si contents, in general, increased when produced under higher pyrolytic temperatures ({ge}500 C). Both switchgrass biochars caused the most significant water PHC improvements in the Norfolk, Declo and Warden soils compared to the controls. Norfolk soil water tension results at 5 and 60 kPa corroborated that biochar from switchgrass caused the most significant moisture storage improvements. Significant correlation occurred between the PHC for water with soil bulk densities. In general, biochar amendments enhanced the moisture storage capacity of Ultisols and Aridisols, but the effect varied with feedstock selection and pyrolysis temperature.« less

  5. Effects of increasing forest plantation area and management practices on carbon storage and water use in the United States

    NASA Astrophysics Data System (ADS)

    Chen, G.; Hayes, D. J.; Tian, H.

    2013-12-01

    Planted forest area in the United States gradually increased during the last half century, and by 2007 accounted for about 20% of the total forest area in the southern United States and about 13% in the entire country. Intensive plantation management activities - such as slash burning, thinning, weed control, fertilization and the use of genetically improved seedlings - are routinely applied during the forest rotation. However, no comprehensive assessments have been made to examine the impacts of this increased forest plantation area and associated management practices on ecosystem function. In this study, we integrated field measurement data and process-based modeling to quantitatively estimate the changes in carbon storage, nitrogen cycling and water use as influenced by forest plantations in the United States from 1925 to 2007. The results indicated that forest plantations and management practices greatly increased forest productivity, vegetation carbon, and wood product carbon storage in the United States, but slightly reduce soil carbon storage at some areas; however, the carbon sink induced by forest plantations was at the expense of more water use as represented by higher evapotranspiration. Stronger nitrogen and water limitations were found for forest plantations as compared to natural or naturally-regenerated forests.

  6. Modeling the Hydrologic Processes of a Permeable Pavement ...

    EPA Pesticide Factsheets

    A permeable pavement system can capture stormwater to reduce runoff volume and flow rate, improve onsite groundwater recharge, and enhance pollutant controls within the site. A new unit process model for evaluating the hydrologic performance of a permeable pavement system has been developed in this study. The developed model can continuously simulate infiltration through the permeable pavement surface, exfiltration from the storage to the surrounding in situ soils, and clogging impacts on infiltration/exfiltration capacity at the pavement surface and the bottom of the subsurface storage unit. The exfiltration modeling component simulates vertical and horizontal exfiltration independently based on Darcy’s formula with the Green-Ampt approximation. The developed model can be arranged with physically-based modeling parameters, such as hydraulic conductivity, Manning’s friction flow parameters, saturated and field capacity volumetric water contents, porosity, density, etc. The developed model was calibrated using high-frequency observed data. The modeled water depths are well matched with the observed values (R2 = 0.90). The modeling results show that horizontal exfiltration through the side walls of the subsurface storage unit is a prevailing factor in determining the hydrologic performance of the system, especially where the storage unit is developed in a long, narrow shape; or with a high risk of bottom compaction and clogging. This paper presents unit

  7. Plant extract enhances the viability of Lactobacillus delbrueckii subsp. bulgaricus and Lactobacillus acidophilus in probiotic nonfat yogurt.

    PubMed

    Michael, Minto; Phebus, Randall K; Schmidt, Karen A

    2015-01-01

    A commercial plant extract (prepared from olive, garlic, onion and citrus extracts with sodium acetate (SA) as a carrier) was evaluated to extend the viability of yogurt starter and probiotic bacteria as a means to enhance the shelf life of live and active culture, probiotic nonfat yogurt. Yogurts prepared from three different formulas (0.5* plant extract, 0.25* SA, or no supplement) and cultures (yogurt starter plus Bifidobacterium animalis,Lactobacillus acidophilus, or both probiotics) were assessed weekly during 29 days of storage at 5°C. Supplemented yogurt mixes had greater buffering capacities than non-supplemented yogurt mixes. At the end of storage, Lactobacillus bulgaricus and L. acidophilus counts in supplemented yogurts were greater compared with non-supplemented yogurts. Supplementation did not affect Streptococcus thermophilus and B. animalis counts. Hence the greater buffering capacity of yogurt containing plant extract could enhance the longevity of the probiotics, L. bulgaricus and L. acidophilus, during storage.

  8. Plant extract enhances the viability of Lactobacillus delbrueckii subsp. bulgaricus and Lactobacillus acidophilus in probiotic nonfat yogurt

    PubMed Central

    Michael, Minto; Phebus, Randall K; Schmidt, Karen A

    2015-01-01

    A commercial plant extract (prepared from olive, garlic, onion and citrus extracts with sodium acetate (SA) as a carrier) was evaluated to extend the viability of yogurt starter and probiotic bacteria as a means to enhance the shelf life of live and active culture, probiotic nonfat yogurt. Yogurts prepared from three different formulas (0.5* plant extract, 0.25* SA, or no supplement) and cultures (yogurt starter plus Bifidobacterium animalis,Lactobacillus acidophilus, or both probiotics) were assessed weekly during 29 days of storage at 5°C. Supplemented yogurt mixes had greater buffering capacities than non-supplemented yogurt mixes. At the end of storage, Lactobacillus bulgaricus and L. acidophilus counts in supplemented yogurts were greater compared with non-supplemented yogurts. Supplementation did not affect Streptococcus thermophilus and B. animalis counts. Hence the greater buffering capacity of yogurt containing plant extract could enhance the longevity of the probiotics, L. bulgaricus and L. acidophilus, during storage. PMID:25650127

  9. A self-sustaining high-strength wastewater treatment system using solar-bio-hybrid power generation.

    PubMed

    Bustamante, Mauricio; Liao, Wei

    2017-06-01

    This study focuses on system analysis of a self-sustaining high-strength wastewater treatment concept combining solar technologies, anaerobic digestion, and aerobic treatment to reclaim water. A solar bio-hybrid power generation unit was adopted to power the wastewater treatment. Concentrated solar power (CSP) and photovoltaics (PV) were combined with biogas energy from anaerobic digestion. Biogas is also used to store the extra energy generated by the hybrid power unit and ensure stable and continuous wastewater treatment. It was determined from the energy balance analysis that the PV-bio hybrid power unit is the preferred energy unit to realize the self-sustaining high-strength wastewater treatment. With short-term solar energy storage, the PV-bio-hybrid power unit in Phoenix, AZ requires solar collection area (4032m 2 ) and biogas storage (35m 3 ), while the same unit in Lansing, MI needs bigger solar collection area and biogas storage (5821m 2 and 105m 3 , respectively) due to the cold climate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Stability of polymorphic forms of ranitidine hydrochloride.

    PubMed

    Wu, V; Rades, T; Saville, D J

    2000-07-01

    Ranitidine-HCl can exist in two different polymorphic forms: form I (m.p. 134-140 degrees C) and form II (m.p. 140-144 degrees C). In the present study the stability of form I of ranitidine-HCl to a selection of powder pretreatments, to reflect conditions which might occur in manufacturing procedures, and also to a limited range of storage conditions was investigated. The original samples of form I and form II used were characterised by X-ray powder diffraction (XRPD), hot stage microscopy (HSM) and differential scanning calorimetry (DSC). A quantitative XRPD method for determining the fraction of form II in the presence of form I was used. XRPD data were analysed using regression techniques and artificial neural networks (ANN). The quantitative XRPD technique was then used to monitor the relative proportion of form II in each treated sample. Pretreatments of form I included (i) mixing with form II or with common excipients (ii) compression and grinding (iii) contact with solvents (followed by drying) before storage. Storage conditions involved three temperatures (20 degrees C, 30 degrees C, 42 degrees C) and three relative humidities (45% RH; 55% RH; 75% RH). Samples were stored for a period of 6 months. A limited factorial design was used. No increase in the form II:form I ratio was observed in the following pretreatment processes: introduction of form II nuclei into form I; introduction of excipients to form I; compression of form I powder at 5 and 15 tons; normal mixing and grinding processes; addition of isopropanol (IPA) or water/IPA mix followed by drying. In the pretreatment process where water was added to form I powder (with most or all of the powder dissolving), drying of the liquefied mass led to a mix of form I and form II. On storage at room temperature (20-30 degrees C), low relative humidity (45-55% RH), and in an air-tight container there was no increase in the form II:form I ratio. Storage of form I/form II mixes, particularly at high humidity, resulted in a preferential loss of form II (compared to form I). Loss was greater at 30 degrees C/75% RH than at 20 degrees C/75% RH. Form II was also preferentially lost under low humidity conditions created by a saturated solution of potassium carbonate (45% RH) at the elevated temperature of 42 degrees C. This environment was shown to be acidic.

  11. 21 CFR 606.160 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...

  12. 21 CFR 606.160 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...

  13. 21 CFR 606.160 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...

  14. 21 CFR 606.160 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...

  15. 21 CFR 606.160 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...

  16. Validity of Monod kinetics at different sludge ages--peptone biodegradation under aerobic conditions.

    PubMed

    Orhon, Derin; Cokgor, Emine Ubay; Insel, Guclu; Karahan, Ozlem; Katipoglu, Tugce

    2009-12-01

    The study presented an evaluation of the effect of culture history (sludge age) on the growth kinetics of a mixed culture grown under aerobic conditions. It involved an experimental setup where a lab-scale sequencing batch reactor was operated at steady-state at two different sludge ages (theta(X)) of 2 and 10 days. The system sustained a mixed culture fed with a synthetic substrate mainly consisting of peptone. The initial concentration of substrate COD was selected around 500 mg COD/L. Polyhydroxyalkanoate (PHA) storage occurred to a limited extent, around 30 mg COD/L for theta(X)=10 days and 15 mg COD/L for theta(X)=2 days. Evaluation of the experimental data based on calibration of two different models provided consistent and reliable evidence for a variable Monod kinetics where the maximum specific growth rate, was assessed as 6.1/day for theta(X)=2 days and 4.1/day for theta(X)=10 days. A similar variability was also applicable for the hydrolysis and storage kinetics. The rate of storage was significantly lower than the levels reported in the literature, exhibiting the ability of the microorganisms to regulate their metabolic mechanisms for adjusting the rate of microbial growth and storage competing for the same substrate. This adjustment evidently resulted in case-specific, variable kinetics both for microbial growth and substrate storage.

  17. Apparatus and method for continuous production of materials

    DOEpatents

    Chang, Chih-hung; Jin, Hyungdae

    2014-08-12

    Embodiments of a continuous-flow injection reactor and a method for continuous material synthesis are disclosed. The reactor includes a mixing zone unit and a residence time unit removably coupled to the mixing zone unit. The mixing zone unit includes at least one top inlet, a side inlet, and a bottom outlet. An injection tube, or plurality of injection tubes, is inserted through the top inlet and extends past the side inlet while terminating above the bottom outlet. A first reactant solution flows in through the side inlet, and a second reactant solution flows in through the injection tube(s). With reference to nanoparticle synthesis, the reactant solutions combine in a mixing zone and form nucleated nanoparticles. The nucleated nanoparticles flow through the residence time unit. The residence time unit may be a single conduit, or it may include an outer housing and a plurality of inner tubes within the outer housing.

  18. The Collyhurst Sandstone as a secondary storage unit for CCS in the East Irish Sea Basin (UK)

    NASA Astrophysics Data System (ADS)

    Gamboa, D.; Williams, J. D. O.; Kirk, K.; Gent, C. M. A.; Bentham, M.; Schofield, D. I.

    2016-12-01

    Carbon Capture and Storage (CCS) is key technology for low-carbon energy and industry. The UK hosts a large CO2 storage potential offshore with an estimated capacity of 78 Gt. The East Irish Sea Basin (EISB) is the key area for CCS in the western UK, with a CO2 storage potential of 1.7 Gt in hydrocarbon fields and in saline aquifers within the Triassic Sherwood Sandstone Formation. However, this theoretical storage capacity does not consider the secondary storage potential in the lower Permian Collyhurst Sandstone Formation. 3D seismic data were used to characterise the Collyhurst Sandstone Formation in the EISB. On the southern basin domain, numerous fault-bound blocks limit the lateral continuity of the sandstone strata, while on the northern domain the sandstones are intersected by less faults. The caprock for the Collyhurst sandstones is variable. The Manchester Marls predominate in the south, transitioning to the St. Bees evaporites towards the north. The evaporites in the EISB cause overburden faults to terminate or detach along Upper Permian strata, limiting the deformation of the underlying reservoir units. Five main storage closures have been identified in the Permian strata. In the southern and central area these are predominantly fault bounded, occurring at depths over 1000m. Despite the higher Collyhurst sandstone thickness in the southern IESB, the dolomitic nature of the caprock constitutes a storage risk in this area. Closures in the northern area are deeper (around 2000-2500m) and wider, reaching areas of 34Km2, and are overlain by evaporitic caprocks. The larger Collyhurst closures to the north underlie large Triassic fields with high storage potential. The spatial overlap favours storage plans including secondary storage units in the EISB. The results of this work also expand the understanding of prospective areas for CO2 sequestration in the East Irish Sea Basin in locations where the primary Sherwood Sandstone Formation is either too shallow, discontinuous or eroded.

  19. CO2 storage capacity estimates from fluid dynamics (Invited)

    NASA Astrophysics Data System (ADS)

    Juanes, R.; MacMinn, C. W.; Szulczewski, M.

    2009-12-01

    We study a sharp-interface mathematical model for the post-injection migration of a plume of CO2 in a deep saline aquifer under the influence of natural groundwater flow, aquifer slope, gravity override, and capillary trapping. The model leads to a nonlinear advection-diffusion equation, where the diffusive term describes the upward spreading of the CO2 against the caprock. We find that the advective terms dominate the flow dynamics even for moderate gravity override. We solve the model analytically in the hyperbolic limit, accounting rigorously for the injection period—using the true end-of-injection plume shape as an initial condition. We extend the model by incorporating the effect of CO2 dissolution into the brine, which—we find—is dominated by convective mixing. This mechanism enters the model as a nonlinear sink term. From a linear stability analysis, we propose a simple estimate of the convective dissolution flux. We then obtain semi-analytic estimates of the maximum plume migration distance and migration time for complete trapping. Our analytical model can be used to estimate the storage capacity (from capillary and dissolution trapping) at the geologic basin scale, and we apply the model to various target formations in the United States. Schematic of the migration of a CO2 plume at the geologic basin scale. During injection, the CO2 forms a plume that is subject to gravity override. At the end of the injection, all the CO2 is mobile. During the post-injection period, the CO2 migrates updip and also driven by regional groundwater flow. At the back end of the plume, where water displaces CO2, the plume leaves a wake or residual CO2 due to capillary trapping. At the bottom of the moving plume, CO2 dissolves into the brine—a process dominated by convective mixing. These two mechanisms—capillary trapping and convective dissolution—reduce the size of the mobile plume as it migrates. In this communication, we present an analytical model that predicts the migration distance and time for complete trapping. This is used to estimate storage capacity of geologic formations at the basin scale.

  20. Carbon dioxide emissions effects of grid-scale electricity storage in a decarbonizing power system

    NASA Astrophysics Data System (ADS)

    Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias

    2018-01-01

    While grid-scale electricity storage (hereafter ‘storage’) could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO2 emissions, we quantify the effect of storage on operational CO2 emissions as a power system decarbonizes under a moderate and strong CO2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. We conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO2 emissions with and without storage. We find that storage would increase CO2 emissions in the current ERCOT system, but would decrease CO2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO2 emissions.

  1. Molecular solar thermal energy storage in photoswitch oligomers increases energy densities and storage times.

    PubMed

    Mansø, Mads; Petersen, Anne Ugleholdt; Wang, Zhihang; Erhart, Paul; Nielsen, Mogens Brøndsted; Moth-Poulsen, Kasper

    2018-05-16

    Molecular photoswitches can be used for solar thermal energy storage by photoisomerization into high-energy, meta-stable isomers; we present a molecular design strategy leading to photoswitches with high energy densities and long storage times. High measured energy densities of up to 559 kJ kg -1 (155 Wh kg -1 ), long storage lifetimes up to 48.5 days, and high quantum yields of conversion of up to 94% per subunit are demonstrated in norbornadiene/quadricyclane (NBD/QC) photo-/thermoswitch couples incorporated into dimeric and trimeric structures. By changing the linker unit between the NBD units, we can at the same time fine-tune light-harvesting and energy densities of the dimers and trimers so that they exceed those of their monomeric analogs. These new oligomers thereby meet several of the criteria to be met for an optimum molecule to ultimately enter actual devices being able to undergo closed cycles of solar light-harvesting, energy storage, and heat release.

  2. Association between length of storage of red blood cell units and outcome of critically ill children: a prospective observational study

    PubMed Central

    2010-01-01

    Introduction Transfusion is a common treatment in pediatric intensive care units (PICUs). Studies in adults suggest that prolonged storage of red blood cell units is associated with worse clinical outcome. No prospective study has been conducted in children. Our objectives were to assess the clinical impact of the length of storage of red blood cell units on clinical outcome of critically ill children. Methods Prospective, observational study conducted in 30 North American centers, in consecutive patients aged <18 years with a stay ≥ 48 hours in a PICU. The primary outcome measure was the incidence of multiple organ dysfunction syndrome after transfusion. The secondary outcomes were 28-day mortality and PICU length of stay. Odds ratios were adjusted for gender, age, number of organ dysfunctions at admission, total number of transfusions, and total dose of transfusion, using a multiple logistic regression model. Results The median length of storage was 14 days in 296 patients with documented length of storage. For patients receiving blood stored ≥ 14 days, the adjusted odds ratio for an increased incidence of multiple organ dysfunction syndrome was 1.87 (95% CI 1.04;3.27, P = 0.03). There was also a significant difference in the total PICU length of stay (adjusted median difference +3.7 days, P < 0.001) and no significant change in mortality. Conclusions In critically ill children, transfusion of red blood cell units stored for ≥ 14 days is independently associated with an increased occurrence of multiple organ dysfunction syndrome and prolonged PICU stay. PMID:20377853

  3. Development of thermal energy storage units for spacecraft cryogenic coolers

    NASA Technical Reports Server (NTRS)

    Richter, R.; Mahefkey, E. T.

    1980-01-01

    Thermal Energy Storage Units were developed for storing thermal energy required for operating Vuilleumier cryogenic space coolers. In the course of the development work the thermal characteristics of thermal energy storage material was investigated. By three distinctly different methods it was established that ternary salts did not release fusion energy as determined by ideality at the melting point of the eutectic salt. Phase change energy was released over a relatively wide range of temperature with a large change in volume. This strongly affects the amount of thermal energy that is available to the Vuilleumier cryogenic cooler at its operating temperature range and the amount of thermal energy that can be stored and released during a single storage cycle.

  4. Mixed Traffic Information Collection System based on Pressure Sensor

    NASA Astrophysics Data System (ADS)

    Liao, Wenzhe; Liu, Mingsheng; Meng, Qingli

    The traffic information collection is the base of Intelligent Traffic.At present, there exist mixed traffic situation in urban road in China. This paper researched and implemented a system through collecting the vehicle and bicycle mixed traffic flow parameters based on pressure sensor. According to information collection requirements, we selected pressure sensor, designed the data collection, storage and other hardware circuitries and information processing software. The experiment shows that the system can meet the demand of traffic information collection in the actual.

  5. Extravehicular mobility unit subcritical liquid oxygen storage and supply system

    NASA Technical Reports Server (NTRS)

    Anderson, John; Martin, Timothy; Hodgson, ED

    1992-01-01

    The storage of life support oxygen in the Extravehicular Mobility Unit in the liquid state offers some advantages over the current method of storing the oxygen as a high pressure gas. Storage volume is reduced because of the increased density associated with liquid. The lower storage and operating pressures also reduce the potential for leakage or bursting of the storage tank. The potential for combustion resulting from adiabatic combustion of the gas within lines and components is substantially reduced. Design constraints on components are also relaxed due to the lower system pressures. A design study was performed to determine the requirements for a liquid storage system and prepare a conceptual design. The study involved four tasks. The first was to identify system operating requirements that influence or direct the design of the system. The second was to define candidate storage system concepts that could possibly satisfy the requirements. An evaluation and comparison of the candidate concepts was conducted in the third task. The fourth task was devoted to preparing a conceptual design of the recommended storage system and to evaluate concerns with integration of the concept into the EMU. The results are presented.

  6. Monolithic Gyroidal Mesoporous Mixed Titanium–Niobium Nitrides

    PubMed Central

    2015-01-01

    Mesoporous transition metal nitrides are interesting materials for energy conversion and storage applications due to their conductivity and durability. We present ordered mixed titanium–niobium (8:2, 1:1) nitrides with gyroidal network structures synthesized from triblock terpolymer structure-directed mixed oxides. The materials retain both macroscopic integrity and mesoscale ordering despite heat treatment up to 600 °C, without a rigid carbon framework as a support. Furthermore, the gyroidal lattice parameters were varied by changing polymer molar mass. This synthesis strategy may prove useful in generating a variety of monolithic ordered mesoporous mixed oxides and nitrides for electrode and catalyst materials. PMID:25122534

  7. Contribution of Increasing CO2 and Climate to Carbon Storage by Ecosystems in the United States

    Treesearch

    David Schimel; Jerry Melillo; Hanqin Tian; A. David McGuire; David Kicklighter; Timothy Kittel; Nan Rosenbloom; Steven Running; Peter Thorton; Dennis Ojima; William Parton; Robin Kelly; Martin Sykes; Ron Neilson; Brian Rizzo

    2000-01-01

    The effects of increasing carbon dioxide (CO2) and climate on net carbon storage in terrestrial ecosystems of the conterminous United States for the period 1895-1993 were modeled with new, detailed historical climate information. For the period 1980-1993, results from an ensemble of three models agree within 25%, simulating a land carbon sink...

  8. Effects of forest regrowth and urbanization on ecosystem carbon storage in a rural–urban gradient in the Southeastern United States

    Treesearch

    Chi Zhang; Hanqin Tian; Shufen Pan; Mingliang Liu; Graeme Lockaby; Erik B. Schilling; John Stanturf

    2008-01-01

    Forest regrowth after cropland abandonment and urban sprawl are two counteracting processes that have influenced carbon (C) sequestration in the southeastern United States in recent decades. In this study, we examined patterns of land-use/landcover change and their effect on ecosystem C storage in three west Georgia counties (Muscogee,...

  9. Effects of stand and inter-specific stocking on maximizing standing tree carbon stocks in the eastern United States

    Treesearch

    Christopher W. Woodall; Anthony W. D' Amato; John B. Bradford; Andrew O. Finley

    2011-01-01

    There is expanding interest in management strategies that maximize forest carbon (C) storage to mitigate increased atmospheric carbon dioxide. The tremendous tree species diversity and range of stand stocking found across the eastern United States presents a challenge for determining optimal combinations for the maximization of standing tree C storage. Using a...

  10. Breast Milk Collection and Storage in the Neonatal Intensive Care Unit: Nurses' Knowledge, Practice, and Perceived Barriers.

    PubMed

    Gharaibeh, Huda Falah; Al-Sheyab, Nihaya; Malkawi, Shefa Yousef

    2016-12-01

    Temporary storage of human milk under appropriate conditions encourages prolonged breast-feeding. This study aimed to assess neonatal nurses' knowledge and practice, as well as barriers, related to breast milk collection and storage and to investigate the association between nurses' knowledge and practice and other variables. A cross-sectional design was used. Consecutive samplings of 75 nurses were recruited. The questions were based on a literature review of guidelines for collecting and storing breast milk from various sources, such as the Centers for Disease Control and Prevention and the Academy of Breastfeeding Medicine. Nurses' knowledge and practice of breast milk collection and storage were adequate in general, but inadequate in relation to issues such as discarding breast milk, the thawing process, and storage temperatures. Poor practices related to absence of required equipment and unit policy. Barriers were increased workload, inappropriate milk room (i.e., a small room with uncomfortable chairs and no privacy), inactive policy, and inadequate time. Nurses should be orientated to the guidelines and a unit policy to enhance evidence-based practice. J Contin Educ Nurs. 2016;47(12):551-557. Copyright 2016, SLACK Incorporated.

  11. A basic study on Thermosyphon-type thermal storage unit (TSU) using Nanofluid as the heat transfer medium

    NASA Astrophysics Data System (ADS)

    Li, Shuang-Fei; Wang, Ping-Yang; Liu, Zhen-hua

    2018-05-01

    This study proposed a novel thermosyphon-type thermal storage unit using water-based CuO nanofluid as the phase-change heat transfer medium. Seven tubular canisters containing solid-liquid phase-change material (PCM) with peak melting temperature of 100 °C were placed vertically into the center of the TSU which is a vertical cylindrical vessel made of stainless steel. Coat formed by depositing nanoparticles during the phase-change process was adopted to increase the wettability of the heat transfer surfaces of the canisters. We investigated the phase-change heat transfer, as well as the heat-storage and heat-release properties, of the TSU through experimental and computational analysis. Our results demonstrate that this thermal storage unit construction can propose good heat transfer and heat-storage/heat-release performance. The coating of nanoparticles onto the heat transfer surfaces increases the surface wettability and improves both the evaporation and condensation heat transfer. The main thermal resistance in the TSU results from the conductive heat transfer inside of the PCM. All phase-change thermal resistance of liquid film in charging and discharging processes can be ignored in this TSU.

  12. Effectiveness of purging on preventing gas emission buildup in wood pellet storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yazdanpanah, Fahimeh; Sokhansanj, Shahab; Lim, Choon Jim

    Storage of wood pellets has resulted in deadly accidents in connection with off-gassing and self-heating. A forced ventilation system should be in place to sweep the off-gases and control the thermal conditions. In this study, multiple purging tests were conducted in a pilot scale silo to evaluate the effectiveness of a purging system and quantify the time and volume of the gas needed to sweep the off-gases. To identify the degree of mixing, residence time distribution of the tracer gas was also studied experimentally. Large deviations from plug flow suggested strong gas mixing for all superficial velocities. As the velocitymore » increased, the system dispersion number became smaller, which indicated less degree of mixing with increased volume of the purging gas. Finally, one-dimensional modelling and numerical simulation of the off-gas concentration profile gave the best agreement with the measured gas concentration at the bottom and middle of the silo.« less

  13. Effectiveness of purging on preventing gas emission buildup in wood pellet storage

    DOE PAGES

    Yazdanpanah, Fahimeh; Sokhansanj, Shahab; Lim, Choon Jim; ...

    2015-04-24

    Storage of wood pellets has resulted in deadly accidents in connection with off-gassing and self-heating. A forced ventilation system should be in place to sweep the off-gases and control the thermal conditions. In this study, multiple purging tests were conducted in a pilot scale silo to evaluate the effectiveness of a purging system and quantify the time and volume of the gas needed to sweep the off-gases. To identify the degree of mixing, residence time distribution of the tracer gas was also studied experimentally. Large deviations from plug flow suggested strong gas mixing for all superficial velocities. As the velocitymore » increased, the system dispersion number became smaller, which indicated less degree of mixing with increased volume of the purging gas. Finally, one-dimensional modelling and numerical simulation of the off-gas concentration profile gave the best agreement with the measured gas concentration at the bottom and middle of the silo.« less

  14. Nutrient Losses during Winter and Summer Storage of Separated and Unseparated Digested Cattle Slurry.

    PubMed

    Perazzolo, Francesca; Mattachini, Gabriele; Riva, Elisabetta; Provolo, Giorgio

    2017-07-01

    Management factors affect nutrient loss during animal manure slurry storage in different ways. We conducted a pilot-scale study to evaluate carbon (C) and nitrogen (N) losses from unseparated and digested dairy slurry during winter and summer storage. In addition to season, treatments included mechanical separation of digestate into liquid and solid fractions and bimonthly mixing. Chemical analyses were performed every 2 wk for the mixed materials and at the start and end of storage for unmixed materials. The parameters examined allowed us to estimate C and N losses and examine the factors that determine these losses as well as emission patterns. Gas measurements were done every 2 wk to determine the main forms in which gaseous losses occurred. To evaluate the effect of separation, measured losses and emissions of separated liquid and solid fractions were mathematically combined using the mass separation efficiency of the mechanical separator. Nutrient losses were mainly affected by climatic conditions. Losses of C (up to 23%) from unseparated, unmixed digestate and of N (38% from combined separated fractions and from unseparated digestate) were much greater in summer than in winter, when C and N losses were <7%. Mixing tended to significantly increase N losses ( < 0.1) only in winter. Mechanical separation resulted in lower GHG emissions from combined separated fractions than from unseparated digestate. Results indicate that to maximize the fertilizer value of digested slurry, dairy farmers must carefully choose management practices, especially in summer. For separated digestates, practices should focus on storage of the liquid fraction, the major contributor of C and N losses (up to 64 and 90% of total losses, respectively) in summer. Moreover, management practices should limit NH, the main form of N losses (up to 99.5%). Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  15. Flexible operation of batteries in power system scheduling with renewable energy

    DOE PAGES

    Li, Nan; Uckun, Canan; Constantinescu, Emil M.; ...

    2015-12-17

    The fast growing expansion of renewable energy increases the complexities in balancing generation and demand in the power system. The energy-shifting and fast-ramping capability of energy storage has led to increasing interests in batteries to facilitate the integration of renewable resources. In this paper, we present a two-step framework to evaluate the potential value of energy storage in power systems with renewable generation. First, we formulate a stochastic unit commitment approach with wind power forecast uncertainty and energy storage. Second, the solution from the stochastic unit commitment is used to derive a flexible schedule for energy storage in economic dispatchmore » where the look-ahead horizon is limited. Here, analysis is conducted on the IEEE 24-bus system to demonstrate the benefits of battery storage in systems with renewable resources and the effectiveness of the proposed battery operation strategy.« less

  16. Jet mixing in low gravity - Results of the Tank Pressure Control Experiment

    NASA Technical Reports Server (NTRS)

    Bentz, M. D.; Meserole, J. S.; Knoll, R. H.

    1992-01-01

    The Tank Pressure Control Experiment (TPCE) is discussed with attention given to the results for controlling storage-tank pressures by forced-convective mixing in microgravitational environments. The fluid dynamics of cryogenic fluids in space is simulated with freon-113 during axial-jet-induced mixing. The experimental flow-pattern data are found to confirm previous data as well as existing mixing correlations. Thermal nonuniformities and tank pressure can be reduced by employing low-energy mixing jets which are useful for enhancing heat/mass transfer between phases. It is found that space cryogenic systems based on the principle of active mixing can be more reliable and predictable than other methods, and continuous or periodic mixing can be accomplished with only minor energy addition to the fluid.

  17. ISO New England Dual Fuel Capabilities to Limit Natural Gas and Electricity Interdependencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adder, Justin M.

    Since 2000, natural gas has seen tremendous growth as a fuel source for electricity generation in the United States (U.S.) with annual installations exceeding 20 GW in all but four years. It also accounts for an increasingly significant share of the nation’s electricity generation, growing from around 15 percent in the early part of the 2000s to between 26 and 29 percent in the last three years. (1) Increasing reliance on natural gas has led to concerns that an extreme weather event – which may cause curtailments in gas delivery – or a natural gas infrastructure failure could lead tomore » local or regional electric reliability issues. (2) These concerns stem from differences in delivery methods of natural gas to electric generating units (EGUs) contrasted with the fuel delivery and storage methods for traditional baseload power systems (i.e. coal and nuclear units).1 (3) Although it seems that there is an abundance of natural gas in a post-shale gas world, infrastructure limitations and differences in electric and natural gas markets persist that differentiate natural gas-fired generators from traditional baseload power generators. Such concerns can be partially mitigated by modifying natural gas EGUs for operation on secondary fuels and installing on-site fuel storage for the secondary fuel, thus ensuring continuity of operation in the case of a gas delivery problem.2 This report examines technical, regulatory, and market issues associated with operating power plants primarily fueled with natural gas, on a secondary fuel, such as fuel oil or liquefied natural gas (LNG). In addition, a regional case study was completed to identify the current and near-term potential for dual fuel operation in New England, along with a market impact analysis of potential cost savings during an extreme weather event. The New England Independent System Operator (ISO-NE) was selected as the study area based on a preponderance of natural gas-fired generators contributing to the regional generating capacity mix (nearly 50 percent natural gas), limited natural gas supply infrastructure, and the potential for natural gas delivery disruptions due to cold weather events, exacerbated by the lack of bulk natural gas storage in the region.« less

  18. Extending Your Reach.

    ERIC Educational Resources Information Center

    Batterman, Christopher T.

    2002-01-01

    High-density mobile storage (storage units mounted on carriages and rails which move and compact to utilize wasted space) can double the capacity of an existing school library facility. This article describes the benefits of going mobile and looks at the advantages of powered, programmable mobile storage systems. A sidebar describes Michigan…

  19. EFFECTS OF STORAGE ON STABILITY AND PATHOGEN REDUCTION IN BIOSOLIDS

    EPA Science Inventory

    Storage can be an effective means of stabilizing small quantities of wastewater sludge. This paper summarizes the performance of two laboratory-scale sludge storage units and that of four full-scale tanks sampled at four treatment facilities in eastern Nebraska. The bench-scale u...

  20. National assessment of geologic carbon dioxide storage resources: summary

    USGS Publications Warehouse

    ,

    2013-01-01

    The U.S. Geological Survey (USGS) recently completed an evaluation of the technically accessible storage resource (TASR) for carbon dioxide (CO2) for 36 sedimentary basins in the onshore areas and State waters of the United States. The TASR is an estimate of the geologic storage resource that may be available for CO2 injection and storage and is based on current geologic and hydrologic knowledge of the subsurface and current engineering practices. By using a geology-based probabilistic assessment methodology, the USGS assessment team members obtained a mean estimate of approximately 3,000 metric gigatons (Gt) of subsurface CO2 storage capacity that is technically accessible below onshore areas and State waters; this amount is more than 500 times the 2011 annual U.S. energy-related CO2 emissions of 5.5 Gt (U.S. Energy Information Administration, 2012, http://www.eia.gov/environment/emissions/carbon/). In 2007, the Energy Independence and Security Act (Public Law 110–140) directed the U.S. Geological Survey to conduct a national assessment of geologic storage resources for CO2 in consultation with the U.S. Environmental Protection Agency, the U.S. Department of Energy, and State geological surveys. The USGS developed a methodology to estimate storage resource potential in geologic formations in the United States (Burruss and others, 2009, USGS Open-File Report (OFR) 2009–1035; Brennan and others, 2010, USGS OFR 2010–1127; Blondes, Brennan, and others, 2013, USGS OFR 2013–1055). In 2012, the USGS completed the assessment, and the results are summarized in this Fact Sheet and are provided in more detail in companion reports (U.S. Geological Survey Geologic Carbon Dioxide Storage Resources Assessment Team, 2013a,b; see related reports at right). The goal of this project was to conduct an initial assessment of storage capacity on a regional basis, and results are not intended for use in the evaluation of specific sites for potential CO2 storage. The national assessment was a geology-based examination of all sedimentary basins in the onshore and State waters area of the United States that contain storage assessment units (SAUs) that could be defined according to geologic and hydrologic characteristics. Although geologic storage of CO2 may be possible in some areas not assessed by the USGS, the SAUs identified in this assessment represent those areas within sedimentary basins that met the assessment criteria. A geologic description of each SAU was prepared; descriptions for SAUs in several basins are in Warwick and Corum (2012, USGS OFR 2012–1024).

  1. Simulation of the Interaction Between Flywheel Energy Storage and Battery Energy Storage on the International Space Station

    NASA Technical Reports Server (NTRS)

    Trouong, Long V.; Wolff, Frederic J.; Dravid, Narayan V.; Li, Ponlee

    2000-01-01

    Replacement of one module of the battery charge discharge unit (BCDU) of the International Space Station (ISS) by a flywheel energy storage unit (FESU) is under consideration. Integration of these two dissimilar systems is likely to surface difficulties in areas of system stability and fault protection. Other issues that need to be addressed include flywheel charge and discharge profiles and their effect on the ISS power system as well as filter sizing for power Ability purposes. This paper describes a SABER based simulation to study these issues.

  2. Development of a COTS Mass Storage Unit for the Space Readiness Coherent Lidar Experiment

    NASA Technical Reports Server (NTRS)

    Liggin, Karl; Clark, Porter

    1999-01-01

    The technology to develop a Mass Storage Unit (MSU) using commercial-off-the-shelf (COTS) hard drives is an on-going challenge to meet the Space Readiness Coherent Lidar Experiment (SPARCLE) program requirements. A conceptual view of SPARCLE's laser collecting atmospheric data from the shuttle is shown in Figure 1. The determination to develop this technology required several in depth studies before an actual COTS hard drive was selected to continue this effort. Continuing the development of the MSU can, and will, serve future NASA programs that require larger data storage and more on-board processing.

  3. Development of fuel oil management system software: Phase 1, Tank management module. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lange, H.B.; Baker, J.P.; Allen, D.

    1992-01-01

    The Fuel Oil Management System (FOMS) is a micro-computer based software system being developed to assist electric utilities that use residual fuel oils with oil purchase and end-use decisions. The Tank Management Module (TMM) is the first FOMS module to be produced. TMM enables the user to follow the mixing status of oils contained in a number of oil storage tanks. The software contains a computational model of residual fuel oil mixing which addresses mixing that occurs as one oil is added to another in a storage tank and also purposeful mixing of the tank by propellers, recirculation or convection.Themore » model also addresses the potential for sludge formation due to incompatibility of oils being mixed. Part 1 of the report presents a technical description of the mixing model and a description of its development. Steps followed in developing the mixing model included: (1) definition of ranges of oil properties and tank design factors used by utilities; (2) review and adaption of prior applicable work; (3) laboratory development; and (4) field verification. Also, a brief laboratory program was devoted to exploring the suitability of suggested methods for predicting viscosities, flash points and pour points of oil mixtures. Part 2 of the report presents a functional description of the TMM software and a description of its development. The software development program consisted of the following steps: (1) on-site interviews at utilities to prioritize needs and characterize user environments; (2) construction of the user interface; and (3) field testing the software.« less

  4. Development of fuel oil management system software: Phase 1, Tank management module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lange, H.B.; Baker, J.P.; Allen, D.

    1992-01-01

    The Fuel Oil Management System (FOMS) is a micro-computer based software system being developed to assist electric utilities that use residual fuel oils with oil purchase and end-use decisions. The Tank Management Module (TMM) is the first FOMS module to be produced. TMM enables the user to follow the mixing status of oils contained in a number of oil storage tanks. The software contains a computational model of residual fuel oil mixing which addresses mixing that occurs as one oil is added to another in a storage tank and also purposeful mixing of the tank by propellers, recirculation or convection.Themore » model also addresses the potential for sludge formation due to incompatibility of oils being mixed. Part 1 of the report presents a technical description of the mixing model and a description of its development. Steps followed in developing the mixing model included: (1) definition of ranges of oil properties and tank design factors used by utilities; (2) review and adaption of prior applicable work; (3) laboratory development; and (4) field verification. Also, a brief laboratory program was devoted to exploring the suitability of suggested methods for predicting viscosities, flash points and pour points of oil mixtures. Part 2 of the report presents a functional description of the TMM software and a description of its development. The software development program consisted of the following steps: (1) on-site interviews at utilities to prioritize needs and characterize user environments; (2) construction of the user interface; and (3) field testing the software.« less

  5. GENERAL VIEW LOOKING NORTHEAST FROM ATOP A STORAGE TANK, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW LOOKING NORTHEAST FROM ATOP A STORAGE TANK, LOOKING AT THE CATALYZER BUILDINGS. NOTE CIRCULAR FOUNDATION FOR AMMONIA STORAGE TANK AND THE LIQUID AIR BUILDING IN THE UPPPER RIGHT CORNER OF PHOTO. - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL

  6. 46 CFR 108.451 - CO2 storage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...

  7. 46 CFR 108.451 - CO2 storage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...

  8. 46 CFR 108.451 - CO2 storage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...

  9. 46 CFR 108.451 - CO2 storage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...

  10. 46 CFR 108.451 - CO2 storage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...

  11. Storage-stable foamable polyurethane is activated by heat

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Polyurethane foamable mixture remains inert in storage unit activated to produce a rapid foaming reaction. The storage-stable foamable composition is spread as a paste on the surface of an expandable structure and, when heated, yields a rigid open-cell polyurethane foam that is self-bondable to the substrate.

  12. Ecosystem carbon storage and flux in upland/peatland watersheds in northern Minnesota. Chapter 9.

    Treesearch

    David F. Grigal; Peter C. Bates; Randall K. Kolka

    2011-01-01

    Carbon (C) storage and fluxes (inputs and outputs of C per unit time) are central issues in global change. Spatial patterns of C storage on the landscape, both that in soil and in biomass, are important from an inventory perspective and for understanding the biophysical processes that affect C fluxes. Regional and national estimates of C storage are uncertain because...

  13. Physiochemical and antioxidant properties of roselle-mango juice blends; effects of packaging material, storage temperature and time

    PubMed Central

    Mgaya-Kilima, Beatrice; Remberg, Siv Fagertun; Chove, Bernard Elias; Wicklund, Trude

    2015-01-01

    A study was conducted to determine the effects of packaging materials, seasonality, storage temperature and time on physiochemical and antioxidant properties of roselle-mango juice blends. Roselle extract (20%, 40%, 60%, and 80%) was mixed with mango juice and stored in glass and plastic bottles at 4°C and 28°C. Total soluble solids, pH, titratable acidity, reducing sugar, color, vitamin C, total monomeric anthocyanins, total phenols, and antioxidant activity (FRAP) were evaluated in freshly prepared juice, and after, 2, 4, and 6 months of storage. The results showed that total soluble solids, reducing sugars, and pH increased with storage times under different storage time, irrespective of packaging materials. The acidity, color, total monomeric anthocyanin, vitamin C, total phenols, and antioxidant activity decreased during storage irrespective of storage temperature and packaging material. Loss of anthocyanins, total phenols, and vitamin C content were higher in blends stored at 28°C than 4°C. PMID:25838888

  14. Redox Flow Batteries, Hydrogen and Distributed Storage.

    PubMed

    Dennison, C R; Vrubel, Heron; Amstutz, Véronique; Peljo, Pekka; Toghill, Kathryn E; Girault, Hubert H

    2015-01-01

    Social, economic, and political pressures are causing a shift in the global energy mix, with a preference toward renewable energy sources. In order to realize widespread implementation of these resources, large-scale storage of renewable energy is needed. Among the proposed energy storage technologies, redox flow batteries offer many unique advantages. The primary limitation of these systems, however, is their limited energy density which necessitates very large installations. In order to enhance the energy storage capacity of these systems, we have developed a unique dual-circuit architecture which enables two levels of energy storage; first in the conventional electrolyte, and then through the formation of hydrogen. Moreover, we have begun a pilot-scale demonstration project to investigate the scalability and technical readiness of this approach. This combination of conventional energy storage and hydrogen production is well aligned with the current trajectory of modern energy and mobility infrastructure. The combination of these two means of energy storage enables the possibility of an energy economy dominated by renewable resources.

  15. Quantifying the role of urban forests in removing atmospheric carbon dioxide

    Treesearch

    Rowan A. Rowntree; David J. Nowak

    1991-01-01

    Urban land in the United States currently occupies about 69 million acres with an estimated average crown cover of 28% and an estimated tree biomass of about 27 tons/acre. This structure suggests that the current total urban forest carbon storage in the United States is approximately 800 million tons with an estimated annual net carbon storage of around 6.5 million...

  16. Analysis and optimisation of a mixed fluid cascade (MFC) process

    NASA Astrophysics Data System (ADS)

    Ding, He; Sun, Heng; Sun, Shoujun; Chen, Cheng

    2017-04-01

    A mixed fluid cascade (MFC) process that comprises three refrigeration cycles has great capacity for large-scale LNG production, which consumes a great amount of energy. Therefore, any performance enhancement of the liquefaction process will significantly reduce the energy consumption. The MFC process is simulated and analysed by use of proprietary software, Aspen HYSYS. The effect of feed gas pressure, LNG storage pressure, water-cooler outlet temperature, different pre-cooling regimes, liquefaction, and sub-cooling refrigerant composition on MFC performance are investigated and presented. The characteristics of its excellent numerical calculation ability and the user-friendly interface of MATLAB™ and powerful thermo-physical property package of Aspen HYSYS are combined. A genetic algorithm is then invoked to optimise the MFC process globally. After optimisation, the unit power consumption can be reduced to 4.655 kW h/kmol, or 4.366 kW h/kmol on condition that the compressor adiabatic efficiency is 80%, or 85%, respectively. Additionally, to improve the process further, with regards its thermodynamic efficiency, configuration optimisation is conducted for the MFC process and several configurations are established. By analysing heat transfer and thermodynamic performances, the configuration entailing a pre-cooling cycle with three pressure levels, liquefaction, and a sub-cooling cycle with one pressure level is identified as the most efficient and thus optimal: its unit power consumption is 4.205 kW h/kmol. Additionally, the mechanism responsible for the weak performance of the suggested liquefaction cycle configuration lies in the unbalanced distribution of cold energy in the liquefaction temperature range.

  17. Response of cellular stoichiometry and phosphorus storage of the cyanobacteria Aphanizomenon flos-aquae to small-scale turbulence

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Xiao, Yan; Yang, Jixiang; Li, Chao; Gao, Xia; Guo, Jinsong

    2017-11-01

    Turbulent mixing, in particular on a small scale, affects the growth of microalgae by changing diffusive sublayers and regulating nutrient fluxes of cells. We tested the nutrient flux hypothesis by evaluating the cellular stoichiometry and phosphorus storage of microalgae under different turbulent mixing conditions. Aphanizomenon flos-aquae were cultivated in different stirring batch reactors with turbulent dissipation rates ranging from 0.001 51 m2/s3 to 0.050 58 m2/s3, the latter being the highest range observed in natural aquatic systems. Samples were taken in the exponential growth phase and compared with samples taken when the reactor was completely stagnant. Results indicate that, within a certain range, turbulent mixing stimulates the growth of A. flos-aquae. An inhibitory effect on growth rate was observed at the higher range. Photosynthesis activity, in terms of maximum effective quantum yield of PSII (the ratio of F v/ F m) and cellular chlorophyll a, did not change significantly in response to turbulence. However, Chl a/C mass ratio and C/N molar ratio, showed a unimodal response under a gradient of turbulent mixing, similar to growth rate. Moreover, we found that increases in turbulent mixing might stimulate respiration rates, which might lead to the use of polyphosphate for the synthesis of cellular constituents. More research is required to test and verify the hypothesis that turbulent mixing changes the diffusive sublayer, regulating the nutrient flux of cells.

  18. Studies on processing, consumer survey and storage stability of a ready-to-reconstitute fish cutlet mix.

    PubMed

    Shaviklo, G Reza; Thorkelsson, Gudjon; Sveinsdottir, Kolbrun; Pourreza, Fatemeh

    2013-10-01

    A convenience ready-to-reconstitute cutlet mix containing 30% fish protein powder was developed to improve the nutritional quality of the product. Consumer survey was based on the home use test (HUT) method. The acceptance of the fish cutlet mix (FCM) was studied using a 9-point hedonic scale ranging from 1 (extremely dislike) to 9 (extremely like). Product's characteristics and stability were studied during 6 months of storage at 27 ± 2 °C. The FCM packed in a polyethylene bag and cardboard box was stable during the storage period. There were no changes in colour, moisture gain and water activity, and TBARS values remained low. The FCM was accepted by the consumers in the study (n = 85). The average liking was high (7.5 ± 1.3) and it was influenced by frequency of fish and chicken consumption, educational level and household size. People who ate fish once a week liked the product more than other consumers. Also those with higher educational level and bigger household size. The results in this paper are important information for companies planning to develop ready-to-eat products fortified with fish proteins. The products could be means of increasing fish consumption in countries/areas where there is no tradition of consuming fresh or frozen fish.

  19. Impact of Firearm Availability and Gun Regulation on State Suicide Rates.

    PubMed

    Kposowa, Augustine; Hamilton, David; Wang, Katy

    2016-12-01

    Past studies on suicide have investigated the association of firearm ownership and suicide risk in the United States. The aim of the present study was to build on previous work by examining the impact of firearm storage practices and the strictness of firearm regulation on suicide rates at the state level. Data were compiled from primarily three sources. Suicide and firearm ownership information was obtained from the Centers for Disease Control and Prevention. Strictness of handgun regulation was derived from figures available at the Law Center to Prevent Violence, and controls were taken from the US Bureau of the Census. Mixed models were fitted to the data. Household firearm ownership was strongly associated with both suicide by all mechanisms, and firearm suicide. Storage practices had especially elevated consequences on suicide rates. Percent with loaded guns and gun readiness increased suicide rates, and strictness of gun regulation reduced suicide rates. Ready access to firearms can make a difference between life and death. Loaded and unlocked firearms within reach become risk factors for fatal outcomes from suicidal behavior. Future research might want to examine ways of obtaining more recent data on individual firearm ownership. This study proposes several policy recommendations for suicide prevention. © 2016 The American Association of Suicidology.

  20. First-Principles Study of Chemical Mixtures of CaCl2 and MgCl2 Hydrates for Optimized Seasonal Heat Storage

    PubMed Central

    2017-01-01

    Chloride-based salt hydrates form a promising class of thermochemical materials (TCMs), having high storage capacity and fast kinetics. In the charging cycles of these hydrates however hydrolysis might appear along with dehydration. The HCl produced during the hydrolysis degrades and corrodes the storage system. Our GGA-DFT results show that the enthalpy charge during proton formation (an important step in hydrolysis) is much higher for CaCl2·2H2O (33.75 kcal/mol) than for MgCl2·2H2O (19.55 kcal/mol). This is a strong indicator that hydrolysis can be minimized by appropriate chemical mixing of CaCl2 and Mg Cl2 hydrates, which is also confirmed by recent experimental studies. GGA-DFT calculations were performed to obtain and analyze the optimized structures, charge distributions, bonding indicators and harmonic frequencies of various chemical mixtures hydrates and compared them to their elementary salts hydrates. We have further assessed the equilibrium products concentration of dehydration/hydrolysis of the chemical mixtures under a wide range of operating conditions. We observed that chemical mixing leads to an increase of the onset hydrolysis temperature with a maximum value of 79 K, thus increasing the resistance against hydrolysis with respect to the elementary salt hydrates. We also found that the chemical mixing of CaCl2 and MgCl2 hydrates widens the operating dehydration temperature range by a maximum value of 182 K (CaMg2Cl6·2H2O) and lowers the binding enthalpy with respect to the physical mixture by ≈65 kcal/mol for TCM based heat storage systems. PMID:28983386

  1. Langley Air Force Base Marina Repair Environmental Assessment

    DTIC Science & Technology

    2004-08-16

    of human perception for extended periods of time; cosmetic or structural damage could occur to buildings. Table 3-8 presents the minimum distance at...Hazardous Waste Storage Areas (HWSA) where they are stored until disposal is economically practicable or before 90 days has expired , whichever comes...Shop, where paintss paint thinners, ·paint mixing, and cleansing of paint equipment took place between 1950 md 1991. The other is the gasoline storage

  2. The Optimization dispatching of Micro Grid Considering Load Control

    NASA Astrophysics Data System (ADS)

    Zhang, Pengfei; Xie, Jiqiang; Yang, Xiu; He, Hongli

    2018-01-01

    This paper proposes an optimization control of micro-grid system economy operation model. It coordinates the new energy and storage operation with diesel generator output, so as to achieve the economic operation purpose of micro-grid. In this paper, the micro-grid network economic operation model is transformed into mixed integer programming problem, which is solved by the mature commercial software, and the new model is proved to be economical, and the load control strategy can reduce the charge and discharge times of energy storage devices, and extend the service life of the energy storage device to a certain extent.

  3. Tree- Rings Link Climate and Carbon Storage in a Northern Mixed Hardwood Forest

    NASA Astrophysics Data System (ADS)

    Chiriboga, A.

    2007-12-01

    The terrestrial biosphere is a variable sink for atmospheric carbon dioxide. It is important to understand how carbon storage in trees is affected by natural climate variability to better characterize the sink. Quantifying the sensitivity of forest carbon storage to climate will improve carbon budgets and have implications for forest management practices. Here we explore how climate variability affects the ability of a northern mixed hardwood forest in Michigan to sequester atmospheric carbon dioxide in woody tissues. This site is ideal for studies of carbon sequestration; The University of Michigan Biological Station is an Ameriflux site, and has detailed meteorological and biometric records, as well as CO2 flux data. We have produced an 82- year aspen (Populus grandidentata) tree-ring chronology for this site, and measured ring widths at several heights up the bole. These measurements were used to estimate annual wood volume, which represents carbon allocated to aboveground carbon stores. Standard dendroclimatological techniques are used to identify environmental factors (e.g. temperature or precipitation) that drive tree-ring increment variability in the past century, and therefore annual carbon storage in this forest. Preliminary results show that marker years within the tree- ring chronology correspond with years that have cold spring temperatures. This suggests that trees at this site are temperature sensitive.

  4. A fuel cell energy storage system concept for the Space Station Freedom Extravehicular Mobility Unit

    NASA Technical Reports Server (NTRS)

    Adlhart, Otto J.; Rosso, Matthew J., Jr.; Marmolejo, Jose

    1989-01-01

    An update is given on work to design and build a Fuel Cell Energy Storage System (FCESS) bench-tested unit for the Space Station Freedom Extravehicular Mobility Unit (EMU). Fueled by oxygen and hydride-stored hydrogen, the FCESS is being considered as an alternative to the EMU zinc-silver oxide battery. Superior cycle life and quick recharge are the main attributes of FCESS. The design and performance of a nonventing, 28 V, 34 Ahr system with 7 amp rating are discussed.

  5. A fuel cell energy storage system concept for the Space Station Freedom Extravehicular Mobility Unit

    NASA Astrophysics Data System (ADS)

    Adlhart, Otto J.; Rosso, Matthew J., Jr.; Marmolejo, Jose

    1989-03-01

    An update is given on work to design and build a Fuel Cell Energy Storage System (FCESS) bench-tested unit for the Space Station Freedom Extravehicular Mobility Unit (EMU). Fueled by oxygen and hydride-stored hydrogen, the FCESS is being considered as an alternative to the EMU zinc-silver oxide battery. Superior cycle life and quick recharge are the main attributes of FCESS. The design and performance of a nonventing, 28 V, 34 Ahr system with 7 amp rating are discussed.

  6. 7 CFR 3560.152 - Tenant eligibility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... agreement that does not restrict occupancy by income. (c) Requirements for elderly housing, elderly units in... this section, the following occupancy requirements apply to elderly housing, elderly units in mixed housing, and congregate housing or group homes: (1) For elderly housing, elderly units in mixed housing...

  7. 7 CFR 3560.152 - Tenant eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... agreement that does not restrict occupancy by income. (c) Requirements for elderly housing, elderly units in... this section, the following occupancy requirements apply to elderly housing, elderly units in mixed housing, and congregate housing or group homes: (1) For elderly housing, elderly units in mixed housing...

  8. Detail, Unit 4, Worthington MixFlo Pump, Harrison, New Jersey, USA. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, Unit 4, Worthington Mix-Flo Pump, Harrison, New Jersey, USA. All six pump units are of the same size, make, and model - Wellton-Mohawk Irrigation System, Pumping Plant No. 1, Bounded by Gila River & Union Pacific Railroad, Wellton, Yuma County, AZ

  9. Carbon Uptake and Storage in Old-Growth and Second-Growth Forests in Central Vermont

    NASA Astrophysics Data System (ADS)

    Lloyd, A. H.; Weisser, O.

    2013-12-01

    Managing forests towards the goal of maximizing carbon uptake and storage provides an important tool for climate change mitigation. There is significant spatial and temporal variation among forests, even within an ecosystem type, in annual uptake and storage of carbon. Understanding the causes for that variation is important in refining management practices and restoration goals that promote carbon storage. We explore the variation in carbon storage and uptake among forests differing in age in central Vermont, comparing young, intermediate-aged, and old-growth forests. We generally expected that younger forests would have a higher annual uptake of carbon than older forests. Significant uncertainty exists, however, about the temporal trajectory from a young, rapidly growing forest to an old-growth forest that may be in a steady-state, with no net uptake of carbon. Within each forest, we compare differences among functional groups of species (e.g., hardwoods versus softwoods) in contribution to overall forest carbon uptake and storage. Our study sites include an old-growth hemlock/mixed hardwood forest that has not been directly affected by human activities, and which contains trees upwards of 350 years old; a 130-year-old mixed hardwood forest that has recolonized former pasture land; and a 90-year-old mixed hardwood forest on formerly agricultural floodplain land. Carbon storage in live and dead biomass pools was estimated from allometric equations, based on repeated measurements of tree diameters in permanently marked study plots. Historical patterns of carbon storage in living biomass were estimated by reconstructing tree diameter from measured increment cores, and then estimating the living biomass in each year. As expected, the old-growth forest stored almost twice the C in live biomass as the two second-growth forests, which stored equivalent amounts of carbon, despite the difference in age. Dead biomass was a larger pool of C in the old-growth forest than in the two second-growth forests, but still contained only a quarter of the C of the live biomass pool. Both repeated measurements of tree diameters and tree-ring reconstructions of historical patterns of C accumulation suggested that all three forests were continuing to accumulate C in biomass, but the rate differed substantially among sites, with the lowest rates of accumulation occurring in the old-growth forest. Within the old-growth forest, the fastest rates of biomass accumulation occurred in younger hardwoods, which appear to have colonized old canopy gaps in the mid-1800s. Together, these results are consistent with prior research suggesting that C continues to accumulate in temperate forests for hundreds of years. Both species differences and forest age, however, have a significant effect on C uptake and storage.

  10. Geological controls on isotopic signatures of streamflow: results from a nested catchment experiment in Luxembourg (Europe)

    NASA Astrophysics Data System (ADS)

    Pfister, Laurent; McDonnell, Jeffrey J.; Hissler, Christophe; Martinez-Carreras, Nuria; Gourdol, Laurent; Klaus, Julian; François Iffly, Jean; Barnich, François; Stewart, Mike K.

    2014-05-01

    Controls of geology and topography on hydrological metrics, like summer low flow (Grant and Tague, 2004) or dynamic storage (Sayama et al., 2011), have been identified in nested catchment experiments. However, most tracer-based studies on streamflow generation have been carried out in small (10 km2) homogenous catchments (Klaus and McDonnell, 2013). The controlling effects of catchment physiography on how catchments store and release water, and how this eventually controls stream isotope behaviour over a large range of scale are poorly understood. Here, we present results from a nested catchment analysis in the Alzette River basin (Luxembourg, Europe). Our hydro-climatological network consists of 16 recording streamgauges and 21 pluviographs. Catchment areas range from 0.47 to 285 km2, with clean and mixed combinations of distinct geologies ranging from schists to marls, sandstone, dolomite and limestone. Our objective was to identify geological controls on (i) winter runoff ratios, (ii) maximum storage and (iii) isotopic signatures in streamflow. For each catchment we determined average runoff ratios from winter season precipitation-discharge double-mass curves. Maximum catchment storage was based on the dynamic storage change approach of Sayama et al. (2011). Changes in isotopic signatures of streamflow were documented along individual catchment flow duration curves. We found strong correlations between average winter runoff ratios, maximum storage and the prevailing geological settings. Catchments with impermeable bedrock (e.g. marls or schists) were characterised by small storage potential and high average filling ratios. As a consequence, these catchments also exhibited the highest average runoff ratios. In catchments underlain by permeable bedrock (e.g. sandstone), storage potential was significantly higher and runoff ratios were considerably smaller. The isotopic signatures of streamflow showed large differences between catchments. In catchments dominated by permeable bedrock, isotopic signatures of streamflow remained stable throughout the entire flow duration curve consistent with a large storage and mixing potential. On less permeable bedrock substrate, we have observed that isotopic signatures in streamflow were much more variable, due to reduced storage volume and comparatively smaller mixing potential. Other metrics such as catchment size and flowpath length exerted a smaller secondary control on isotopic signatures of streamflow in the Alzette River sub-basins. Tague, C., Grant, G.E., 2004. A geological framework for interpreting the low-flow regimes of Cascade streams, Willamette River Basin, Oregon. Water Resources Research, 40(4), doi:10.1029/2003WR002629 Sayama, T., McDonnell, J.J., Dhakal, A., Sullivan, K., 2011. How much water can a watershed store ? Hydrological Processes 25, 3899-3908. Klaus, J., McDonnell, J.J., 2013. Hydrograph separation using stable isotopes: Review and evaluation. Journal of Hydrology 505, 47-64.

  11. Effect of a commercial housing system on egg quality during extended storage.

    PubMed

    Jones, D R; Karcher, D M; Abdo, Z

    2014-05-01

    Egg producers in the United States are utilizing a variety of commercial egg production systems to provide consumer choice and meet legislative requirements. Consumer egg grades in the United States were developed for conventional cage production, and it is unclear what effect alternative production systems might have on egg quality during retail and consumer home storage. The current study was undertaken to determine what changes in egg quality characteristics occur during extended cold storage for commercially produced conventional cage, enriched colony cage, and cage-free aviary eggs. During 12 wk of cold storage, egg weight, albumen height, Haugh unit, static compression shell strength, vitelline membrane strength and deformation, yolk index, shell dynamic stiffness, and whole egg total solids were monitored. Overall, aviary and enriched eggs were significantly (P < 0.05) heavier than conventional cage. Albumen height and Haugh unit (P < 0.05) were significantly greater for conventional cage than enriched eggs. Static compression shell strength was greatest (P < 0.05) for enriched eggs compared with aviary. No overall housing system effects for yolk measurements, shell dynamic stiffness, or whole egg total solids were observed. Albumen height, Haugh unit, and yolk quality measurements were all greatest at 0 and lowest at 12 wk of storage (P < 0.05). The rate of quality change among the housing systems for each measured attribute at 4, 6, and 12 wk was determined. Other than differences in the change of egg weight at 4 wk, no significant differences in the rate of quality decline were found among the housing systems. The results of the current study indicate that current US egg quality standards should effectively define quality for commercially produced conventional cage, enriched colony cage, and cage-free aviary eggs.

  12. Comparison of Temperature and Additives Affecting the Stability of the Probiotic Weissella cibaria

    PubMed Central

    Kang, Mi-Sun; Kim, Youn-Shin; Lee, Hyun-Chul; Lim, Hoi-Soon

    2012-01-01

    Daily use of probiotic chewing gum might have a beneficial effect on oral health, and it is important that the viability of the probiotics be maintained in this food product. In this study, we examined the stability of probiotic chewing gum containing Weissella cibaria. We evaluated the effects of various factors, including temperature and additives, on the survival of freeze-dried probiotic W. cibaria powder. No changes in viability were detected during storage at 4℃ for 5 months, whereas the viability of bacteria stored at 20℃ decreased. The stability of probiotic chewing gum decreased steadily during storage at 20℃ for 4 weeks. The viability of the freeze-dried W. cibaria mixed with various additives, such as xylitol, sorbitol, menthol, sugar ester, magnesium stearate, and vitamin C, was determined over a 4-week storage period at 20℃. Most of the freeze-dried bacteria except for those mixed with menthol and vitamin C were generally stable during a 3-week storage period. Overall, our study showed that W. cibaria was more stable at 4℃ than that at 20℃. In addition, menthol and vitamin C had a detrimental effect on the storage stability of W. cibaria. This is the first study to examine the effects of various chewing gum additives on the stability of W. cibaria. Further studies will be needed to improve the stability of probiotic bacteria for developing a novel probiotic W. cibaria gum. PMID:23323221

  13. Geologic framework for the national assessment of carbon dioxide storage resources: Greater Green River Basin, Wyoming, Colorado, and Utah, and Wyoming-Idaho-Utah Thrust Belt: Chapter E in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Buursink, Marc L.; Slucher, Ernie R.; Brennan, Sean T.; Doolan, Colin A.; Drake II, Ronald M.; Merrill, Matthew D.; Warwick, Peter D.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.

    2014-01-01

    The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows up on previous USGS work. The methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of 14 storage assessment units (SAUs) in Ordovician to Upper Cretaceous sedimentary rocks within the Greater Green River Basin (GGRB) of Wyoming, Colorado, and Utah, and eight SAUs in Ordovician to Upper Cretaceous sedimentary rocks within the Wyoming-Idaho-Utah Thrust Belt (WIUTB). The GGRB and WIUTB are contiguous with nearly identical geologic units; however, the GGRB is larger in size, whereas the WIUTB is more structurally complex. This report focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in the SAUs. Specific descriptions of the SAU boundaries, as well as their sealing and reservoir units, are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are typically provided to illustrate geologic factors critical to the assessment. This geologic information was employed, as specified in the USGS methodology, to calculate a probabilistic distribution of potential storage resources in each SAU. Figures in this report show SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one square mile and are derived from interpretations of variably attributed well data and a digital compilation that is known not to include all drilling.

  14. Case mix management education in a Canadian hospital.

    PubMed

    Moffat, M; Prociw, M

    1992-01-01

    The Sunnybrook Health Science Centre's matrix organization model includes a traditional departmental structure, a strategic program-based structure and a case management-based structure--the Clinical Unit structure. The Clinical Unit structure allows the centre to give responsibility for the management of case mix and volume to decentralized Clinical Unit teams, each of which manages its own budget. To train physicians and nurses in their respective roles of Medical Unit directors and Nursing Unit directors, Sunnybrook designed unique short courses on financial management and budgeting, and case-costing and case mix management. This paper discusses how these courses were organized, details their contents and explains how they fit into Sunnybrook's program of decentralized management.

  15. Maximising platelet availability by delaying cold storage.

    PubMed

    Wood, B; Johnson, L; Hyland, R A; Marks, D C

    2018-04-06

    Cold-stored platelets may be an alternative to conventional room temperature (RT) storage. However, cold-stored platelets are cleared more rapidly from circulation, reducing their suitability for prophylactic transfusion. To minimise wastage, it may be beneficial to store platelets conventionally until near expiry (4 days) for prophylactic use, transferring them to refrigerated storage to facilitate an extended shelf life, reserving the platelets for the treatment of acute bleeding. Two ABO-matched buffy-coat-derived platelets (30% plasma/70% SSP+) were pooled and split to produce matched pairs (n = 8 pairs). One unit was stored at 2-6°C without agitation (day 1 postcollection; cold); the second unit was stored at 20-24°C with constant agitation until day 4 then stored at 2-6°C thereafter (delayed-cold). All units were tested for in vitro quality periodically over 21 days. During storage, cold and delayed-cold platelets maintained a similar platelet count. While pH and HSR were significantly higher in delayed-cold platelets, other metabolic markers, including lactate production and glucose consumption, did not differ significantly. Furthermore, surface expression of phosphatidylserine and CD62P, release of soluble CD62P and microparticles were not significantly different, suggesting similar activation profiles. Aggregation responses of delayed-cold platelets followed the same trend as cold platelets once transferred to cold storage, gradually declining over the storage period. The metabolic and activation profile of delayed-cold platelets was similar to cold-stored platelets. These data suggest that transferring platelets to refrigerated storage when near expiry may be a viable option for maximising platelet inventories. © 2018 International Society of Blood Transfusion.

  16. [Influence of fire disturbance on aboveground deadwood debris carbon storage in Huzhong forest region of Great Xing'an Mountains, Northeast China].

    PubMed

    Yang, Da; He, Hong-shi; Wu, Zhi-wei; Liang, Yu; Huang, Chao; Luo, Xu; Xiao, Jiang-tao; Zhang, Qing-long

    2015-02-01

    Based on the field inventory data, the aboveground deadwood debris carbon storage under different fire severities was analyzed in Huzhong forest region of Great Xing' an Mountains. The results showed that the fire severity had a significant effect on aboveground deadwood debris carbon storage. The deadwood debris carbon storage was in the order of high-severity > low-severity > unburned in Larix gmelinii stands, and mixed conifer-broadleaf stands ( L. gmelinii and Betula platyphylla), and in the order of high severity > unburned > low-severity in B. platyphylla stands. Fire disturbance significantly changed the component percentage of the deadwood debris carbon storage. The component percentage of snags increased and litter decreased with the increasing fire severity. Logs and stumps did not change significantly with the increasing fire severity. The spatial variation of deadwood debris carbon storage in forests burned with low-severity fire was higher than that in unburned forests. The spatial variation of deadwood debris carbon storage with high-severity fires was lowest. This spatial variation needed to be accounted when calculating forest deadwood debris carbon storage.

  17. Three essays on the effect of wind generation on power system planning and operations

    NASA Astrophysics Data System (ADS)

    Davis, Clay Duane

    While the benefits of wind generation are well known, some drawbacks are still being understood as wind power is integrated into the power grid at increasing levels. The primary difference between wind generation and other forms of generation is the intermittent, and somewhat unpredictable, aspect of this resource. The somewhat uncontrollable aspect of wind generation makes it important to consider the relationship between this resource and load, and also how the operation of other non-wind generation resources may be affected. The three essays that comprise this dissertation focus on these and other important issues related to wind generation; leading to an improved understanding of how to better plan for and utilize this resource. The first essay addresses the cost of increased levels of installed wind capacity from both a capacity planning and economic dispatch perspective to arrive at the total system cost of installing a unit of wind capacity. This total includes not only the cost of the wind turbine and associated infrastructure, but also the cost impact an additional unit of wind capacity has on the optimal mix and operation of other generating units in the electricity supply portfolio. The results of the model showed that for all wind expansion scenarios, wind capacity is not cost-effective regardless of the level of the wind production tax credit and carbon prices that were considered. Larger levels of installed wind capacity result in reduced variable cost, but this reduction is not able to offset increases in capital cost, as a unit of installed wind capacity does not result in an equal reduction in other non-wind capacity needs. The second essay develops a methodology to better handle unexpected short term fluctuations in wind generation within the existing power system. The methodology developed in this essay leads to lower expected costs by anticipating and planning for fluctuations in wind generation by focusing on key constraints in the system. The modified methodology achieves expected costs for the UC-ED problem that are as low as the full stochastic model and markedly lower than the deterministic model. The final essay focuses on valuing energy storage located at a wind site through multiple revenue streams, where energy storage is valued from the perspective of a profit maximizing investor. Given the current state of battery storage technology, a battery capacity of zero is optimal in the setting considered in this essay. The results presented in this essay are dependent on a technological breakthrough that substantially reduces battery cost and conclude that allowing battery storage to simultaneously participate in multiple wholesale markets is optimal relative to participating in any one market alone. Also, co-locating battery storage and wind provides value by altering the optimal transmission line capacity to the battery and wind site. This dissertation considers problems of wind integration from an economic perspective and builds on existing work in this area. The economics of wind integration and utilization are important because wind generation levels are already significant and will likely become more so in the future. While this dissertation adds to the existing literature, additional work is needed in this area to ensure wind generation adds as much value to the overall system as possible.

  18. Oxygen and carbon isotope compositions of carbonates in a prominent lithologically mixed unit in the central South Norwegian Caledonides

    NASA Astrophysics Data System (ADS)

    Jakob, Johannes; Boulvais, Philippe; Andersen, Torgeir B.

    2018-06-01

    A prominent pre-Scandian lithologically mixed unit in the central South Norwegian Caledonides contains more than 100 partly carbonated and hydrated metaperidotite bodies and locally fossiliferous detrital serpentinites. The lateral consistency of this mixed unit was not fully appreciated in the past. Therefore, parts of the mixed unit along strike were interpreted to belong to several different tectonostratigraphic levels. Here, we present new carbonate stable isotope data that suggest that the carbonates of the mixed unit between Bergen and Otta (re-)equilibrated at unit-wide similar peak metamorphic conditions. The isotope compositions are characteristic for this unit and indicate that it represented one single tectonic unit during the Scandian Orogeny. The carbonates in the mélange are characterized by a narrow range of δ18O (SMOW) values between + 11 and + 15.5‰ and three groups of δ13C (PDB) values: (I) + 1.6 to + 0.3‰, (II) - 1.8 to - 3.9‰, and (III) - 6 to - 8.6‰. Carbonates of group III probably were affected by decarbonation or by a fluid containing organic carbon, whereas carbonates of group I and II overlap with δ13C values typical for Ediacaran-Silurian marine carbonates and may have retained their initial δ13C imprint. We suggest that the δ18O values (re-)equilibrated with unit-wide released metamorphic fluids during Scandian metamorphism. An outcrop-scale homogenisation of the δ13C values reflects the local carbon isotope signature of the released metamorphic fluids that circulated channelized through the mélange unit.

  19. Oxygen and carbon isotope compositions of carbonates in a prominent lithologically mixed unit in the central South Norwegian Caledonides

    NASA Astrophysics Data System (ADS)

    Jakob, Johannes; Boulvais, Philippe; Andersen, Torgeir B.

    2017-11-01

    A prominent pre-Scandian lithologically mixed unit in the central South Norwegian Caledonides contains more than 100 partly carbonated and hydrated metaperidotite bodies and locally fossiliferous detrital serpentinites. The lateral consistency of this mixed unit was not fully appreciated in the past. Therefore, parts of the mixed unit along strike were interpreted to belong to several different tectonostratigraphic levels. Here, we present new carbonate stable isotope data that suggest that the carbonates of the mixed unit between Bergen and Otta (re-)equilibrated at unit-wide similar peak metamorphic conditions. The isotope compositions are characteristic for this unit and indicate that it represented one single tectonic unit during the Scandian Orogeny. The carbonates in the mélange are characterized by a narrow range of δ18O (SMOW) values between + 11 and + 15.5‰ and three groups of δ13C (PDB) values: (I) + 1.6 to + 0.3‰, (II) - 1.8 to - 3.9‰, and (III) - 6 to - 8.6‰. Carbonates of group III probably were affected by decarbonation or by a fluid containing organic carbon, whereas carbonates of group I and II overlap with δ13C values typical for Ediacaran-Silurian marine carbonates and may have retained their initial δ13C imprint. We suggest that the δ18O values (re-)equilibrated with unit-wide released metamorphic fluids during Scandian metamorphism. An outcrop-scale homogenisation of the δ13C values reflects the local carbon isotope signature of the released metamorphic fluids that circulated channelized through the mélange unit.

  20. Natural Gas Storage in the United States in 2001: A Current Assessment and Near-Term Outlook

    EIA Publications

    2001-01-01

    This report examines the large decline of underground natural gas storage inventories during the 2000-2001 heating season and the concern that the nation might run out of working gas in storage prior to the close of the heating season on March 31, 2001. This analysis also looks at the current profile and capabilities of the U.S. natural gas underground storage sector.

  1. Design considerations for divers' breathing gas systems

    NASA Technical Reports Server (NTRS)

    Hansen, O. R.

    1972-01-01

    Some of the design methods used to establish the gas storage, mixing, and transfer requirements for existing deep dive systems are discussed. Gas mixing systems appear essential to provide the low oxygen concentration mixtures within the converging tolerance range dictated by applications to increasing depths. Time related use of gas together with the performance of the gas transfer system insures a reasonable time frame for systems application.

  2. National assessment of geologic carbon dioxide storage resources: results

    USGS Publications Warehouse

    ,

    2013-01-01

    In 2012, the U.S. Geological Survey (USGS) completed an assessment of the technically accessible storage resources (TASR) for carbon dioxide (CO2) in geologic formations underlying the onshore and State waters area of the United States. The formations assessed are at least 3,000 feet (914 meters) below the ground surface. The TASR is an estimate of the CO2 storage resource that may be available for CO2 injection and storage that is based on present-day geologic and hydrologic knowledge of the subsurface and current engineering practices. Individual storage assessment units (SAUs) for 36 basins were defined on the basis of geologic and hydrologic characteristics outlined in the assessment methodology of Brennan and others (2010, USGS Open-File Report 2010–1127) and the subsequent methodology modification and implementation documentation of Blondes, Brennan, and others (2013, USGS Open-File Report 2013–1055). The mean national TASR is approximately 3,000 metric gigatons (Gt). The estimate of the TASR includes buoyant trapping storage resources (BSR), where CO2 can be trapped in structural or stratigraphic closures, and residual trapping storage resources, where CO2 can be held in place by capillary pore pressures in areas outside of buoyant traps. The mean total national BSR is 44 Gt. The residual storage resource consists of three injectivity classes based on reservoir permeability: residual trapping class 1 storage resource (R1SR) represents storage in rocks with permeability greater than 1 darcy (D); residual trapping class 2 storage resource (R2SR) represents storage in rocks with moderate permeability, defined as permeability between 1 millidarcy (mD) and 1 D; and residual trapping class 3 storage resource (R3SR) represents storage in rocks with low permeability, defined as permeability less than 1 mD. The mean national storage resources for rocks in residual trapping classes 1, 2, and 3 are 140 Gt, 2,700 Gt, and 130 Gt, respectively. The known recovery replacement storage resource (KRRSR) is a conservative estimate that represents only the amount of CO2 at subsurface conditions that could replace the volume of known hydrocarbon production. The mean national KRRSR, determined from production volumes rather than the geologic model of buoyant and residual traps that make up TASR, is 13 Gt. The estimated storage resources are dominated by residual trapping class 2, which accounts for 89 percent of the total resources. The Coastal Plains Region of the United States contains the largest storage resource of any region. Within the Coastal Plains Region, the resources from the U.S. Gulf Coast area represent 59 percent of the national CO2 storage capacity.

  3. An Evaluation of Energy Storage Options for Nuclear Power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Justin L.; Bragg-Sitton, Shannon M.; Dufek, Eric J.

    Energy supply, distribution, and demand are continuing to evolve as new generation sources come online and new appliances are installed. A larger percentage of the United States (U.S.) energy mix is provided by variable energy sources such as wind and solar each year, and distributed generation is becoming more common. In parallel, an evolution in consumer products such as electrical vehicles, information technology devices for residential and industrial applications, and appliances is changing how energy is consumed. As a result of these trends, nuclear power plants (NPPs) are being called upon to operate more flexibly than ever before. Furthermore, advancedmore » nuclear power plants (A-NPPs) might operate as part of an electricity system that looks very different than when the current NPP fleet was constructed. A-NPPs face the possibility that they will need to operate in an environment where flexibility (e.g., fast ramping) is more highly valued than stability (e.g., baseload generation for conventional demand curves). The current fleet of NPPs is struggling to remain economical in competitive markets in an era of historically low natural gas prices and renewable sources with very low marginal costs. These factors, overlaid with an ambiguous national policy related to nuclear energy and a decision-making context that struggles with multi-decade capital investments, raise key questions and present significant challenges to the economics of nuclear power in the evolving grid. Multiple factors could improve the economics of A-NPPs, including: (1) minimizing the need for active safety systems, (2) minimizing adoption of one-off reactor designs, (3) establishing policies that credit low carbon emitting technologies, and (4) integrating energy storage technologies that increase revenue and reduce costs through a combination of ancillary services, market hedging, and reduced costs via stable operation. This report focuses on Item (4), containing an overview, synthesis, and examination of energy storage options that could be integrated with nuclear generation. Figure 1 provides an overview of the 2015 energy mix by sector, which shows that NPPs are currently used exclusively for electricity generation that is ultimately consumed in the residential, commercial, and industrial sectors. Some areas for NPP energy growth in the future include power generation for electrified transportation and thermal generation for storage and industrial applications. Currently, most industrial thermal energy users combust fossil resources (i.e., coal or natural gas) to meet the energy needs of the processes, but heat from nuclear operations could also be used in certain specific applications.« less

  4. Conjunctive management of multi-reservoir network system and groundwater system

    NASA Astrophysics Data System (ADS)

    Mani, A.; Tsai, F. T. C.

    2015-12-01

    This study develops a successive mixed-integer linear fractional programming (successive MILFP) method to conjunctively manage water resources provided by a multi-reservoir network system and a groundwater system. The conjunctive management objectives are to maximize groundwater withdrawals and maximize reservoir storages while satisfying water demands and raising groundwater level to a target level. The decision variables in the management problem are reservoir releases and spills, network flows and groundwater pumping rates. Using the fractional programming approach, the objective function is defined as a ratio of total groundwater withdraws to total reservoir storage deficits from the maximum storages. Maximizing this ratio function tends to maximizing groundwater use and minimizing surface water use. This study introduces a conditional constraint on groundwater head in order to sustain aquifers from overpumping: if current groundwater level is less than a target level, groundwater head at the next time period has to be raised; otherwise, it is allowed to decrease up to a certain extent. This conditional constraint is formulated into a set of mixed binary nonlinear constraints and results in a mixed-integer nonlinear fractional programming (MINLFP) problem. To solve the MINLFP problem, we first use the response matrix approach to linearize groundwater head with respect to pumping rate and reduce the problem to an MILFP problem. Using the Charnes-Cooper transformation, the MILFP is transformed to an equivalent mixed-integer linear programming (MILP). The solution of the MILP is successively updated by updating the response matrix in every iteration. The study uses IBM CPLEX to solve the MILP problem. The methodology is applied to water resources management in northern Louisiana. This conjunctive management approach aims to recover the declining groundwater level of the stressed Sparta aquifer by using surface water from a network of four reservoirs as an alternative source of supply.

  5. Storage of Buffy-coat-derived platelets in additive solutions: in vitro effects on platelets prepared by the novel TACSI system and stored in plastic containers with different gas permeability.

    PubMed

    Sandgren, P; Hild, M; Sjödin, A; Gulliksson, H

    2010-11-01

    The novel TACSI system is designed for automated preparation of platelets (PLTs) from pooled buffy coats (BCs). One TACSI device will handle 6 units at the same time. The aim of our in vitro study is to investigate the effects of using this automated equipment with subsequent storage in two different plastic containers and to compare these results with PLTs prepared by the OrbiSac system. Buffy-coat-derived PLTs (n=8) were prepared by using the TACSI system, including storage in polyvinyl chloride (PVC)-based plastic containers with di, n-decyl phthalate (DnDP) (TACSI R) and BTHC (TACSI T)-based plasticizers. As a reference, the OrbiSac System was used to prepare PLTs (n=8) with subsequent storage in a PVC plastic container with a citrate-based plasticizer (BTHC). In total, 16 TACSI and eight reference units, supplied by approximately 30% plasma and 70% SSP+, were analysed for various in vitro variables during the 7-day storage period. No significant difference in PLT counts, LDH, mean platelet volume (MPV) and adenosine triphosphate between the groups was detected. Glucose was lower (P<0·05) and lactate was higher (P<0·05) in TACSI R vs. OrbiSac. With exception of day 7 (P<0·05 TACSI R vs. OrbiSac), HSR reactivity were not different between groups. Extent of shape change was lower and CD62P higher in TACSI T when compared with TACSI R and OrbiSac units (P<0·05). pH was maintained at >6·8 (day 7) and swirling remained at the highest level (score=2) for all units throughout storage. Platelets prepared by the TACSI system with subsequent storage in two different PVC-based plastic containers were equivalent to reference PLTs with regard to in vitro characteristics during 7 days of storage. © 2010 The Author(s). Vox Sanguinis © 2010 International Society of Blood Transfusion.

  6. Design and demonstration of a storage assisted air conditioning system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-04-01

    One phase-change material, sodium sulfate decahydrate, has generated considerable interest for thermal storage. A form of this material containing salts to adjust the transition point to approximately 55/sup 0/F and a gelling agent to prevent segregation of the salts has been developed. This material is packaged in the form of a CHUB, (a cylinder two inches in diameter and twenty inches long) having a weight of 3.25 pounds and a thermal storage capability of 50 Btu per pound. Under this project, a storage-assisted (partial storage) air conditioning system was designed, installed, monitored and evaluated in a typical residential application. Thismore » feasibility demonstration was conducted under the direction of the Long Island Lighting Company in a single family residence in Melville, Long Island, New York. The demonstration system consisted of a CHUB thermal storage system utilized in conjunction with a one and one-half ton air conditioning unit to cool a house that would normally require a two and one half ton air conditioning unit.« less

  7. Geologic framework for the national assessment of carbon dioxide storage resources: Denver Basin, Colorado, Wyoming, and Nebraska: Chapter G in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Drake II, Ronald M.; Brennan, Sean T.; Covault, Jacob A.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.

    2014-01-01

    This is a report about the geologic characteristics of five storage assessment units (SAUs) within the Denver Basin of Colorado, Wyoming, and Nebraska. These SAUs are Cretaceous in age and include (1) the Plainview and Lytle Formations, (2) the Muddy Sandstone, (3) the Greenhorn Limestone, (4) the Niobrara Formation and Codell Sandstone, and (5) the Terry and Hygiene Sandstone Members. The described characteristics, as specified in the methodology, affect the potential carbon dioxide storage resource in the SAUs. The specific geologic and petrophysical properties of interest include depth to the top of the storage formation, average thickness, net-porous thickness, porosity, permeability, groundwater quality, and the area of structural reservoir traps. Descriptions of the SAU boundaries and the overlying sealing units are also included. Assessment results are not contained in this report; however, the geologic information included here will be used to calculate a statistical Monte Carlo-based distribution of potential storage volume in the SAUs.

  8. Salt-stressed fresh cut leek accelerates CO₂ and C₂H₄ production and enhances the development of quality characteristics of traditional Greek sausages during storage.

    PubMed

    Madentzidou, Eleftheria; Gerasopoulos, Dimitrios; Siomos, Anastasios; Bloukas, Ioannis

    2012-12-01

    Fresh cut leek was mixed with salt for 0.5 (IM) and 5 (LM) min or remained untreated (control) and stored alone or mixed with minced meat and seasonings, cased and stored at 15 °C for 7 days. The fresh cut leek and sausage metabolics and sausage microbiological and physicochemical traits were measured during storage. Sausages with LM leek had significantly higher counts of lactic acid bacteria, faster rates of pH drop and dehydration and increased red color compared with the other treatments. Sausage to fresh cut leek peaks of CO₂ or C₂H₄ production was 5 or 2 fold higher in LM than the other treatments indicating that the sausage flora was the source of both. The use of salt-stressed fresh cut leek before manufacture of sausages enhances microbial activity as well as its stability and shortens the necessary storage time needed for the development of the quality characteristics of Greek traditional sausages. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Assessment of Energy Storage Technologies for Army Facilities.

    DTIC Science & Technology

    1986-05-01

    units, and the other on tandem units with separate multistage pump and Pelton impulse turbine . The third scheme was a double-drop type based on the...used to drive the turbine /generator. Exhaust gas from the low-pressure turbine may be used to preheat inlet air to the high-pressure turbine . Storage...for firing CAES plant turbines . A Battelle publication summarizes reservoir stability criteria and research directed toward minimizing or eliminating

  10. Variable electronic shutter in CMOS imager with improved anti smearing techniques

    NASA Technical Reports Server (NTRS)

    Pain, Bedabrata (Inventor)

    2005-01-01

    A leakage compensated snapshot imager provides a number of different aspects to prevent smear and other problems in a snapshot imager. The area where the imager is formed may be biased in a way that prevents photo carriers including electrons and holes from reaching a storage area. In addition, a number of different aspects may improve the efficiency. The capacitance per unit area of the storage area may be one, two or more orders of magnitude greater than the capacitance per-unit area of the photodiode. In addition, a ratio between photodiode capacitance and storage area capacitance is maintained larger than 0.7.

  11. Increasing hemoglobin oxygen saturation levels in sickle trait donor whole blood prevents hemoglobin S polymerization and allows effective white blood cell reduction by filtration.

    PubMed

    Stroncek, David F; Byrne, Karen M; Noguchi, Constance T; Schechter, Alan N; Leitman, Susan F

    2004-09-01

    BACKGROUND Red blood cell (RBC) components from donors with sickle cell trait (Hb AS) often occlude white blood cell (WBC) reduction filters. Techniques were investigated to successfully filter Hb AS donor blood by increasing the Hb oxygen saturation with storage bags and conditions suitable for transfusion products. Oxygenation kinetics were measured over 3 days in whole-blood units stored in standard-sized 600-mL polyvinylchloride (PVC) bags and whole-blood units divided into three equal parts and stored in standard-sized blood bags made from PVC, tri-2-(ethylhexyl)trimellitate (CLX) plastic, or Teflon. The filterability of Hb AS blood stored for 3 days was tested with whole-blood filters. Oxygen saturation levels did not increase in full whole-blood units from donors without sickle cell trait during 3 days of storage in 600-mL PVC bags. In divided Hb AS whole-blood units stored for 3 days, oxygen saturation levels increased from baseline levels of 45 to 56, 66, and 94 percent after storage in 600-mL PVC, CLX, and Teflon bags, respectively (n = 5, p < 0.02), and all components filtered completely. When full Hb AS whole-blood units from eight donors were stored for 3 days in 1.5-L CLX bags, all units filtered completely, but one had a high residual WBC count. Storage of Hb AS whole blood in large-capacity oxygen-permeable bags increases oxygen tension and allows more effective WBC reduction by filtration.

  12. Strategic use of the underground for an energy mix plan, synergies among CO2 and CH4 Geological Storage and Geothermal Energy: Italian Energy review and Latium case study

    NASA Astrophysics Data System (ADS)

    Procesi, M.; Cantucci, B.; Buttinelli, M.; Armezzani, G.; Quattrocchi, F.

    2012-04-01

    Since the world-wide energy demand has been growing so much in the last years, it is necessary to develop a strategic mix-energy plan to supply low GHG (GreenHouseGas) emissions energy and solve the problem of CO2 emission increasing. A recent study published by European Commission shows that, if existing trends continue, by 2050 CO2 emissions will be unsustainably high: 900-1000 parts per million by volume. The European Commission in 2007 underline the necessity to elaborate, at European level, a Strategic Energy Technology Plan focused on non-carbon or reduced-carbon sources of energy, as renewable energies, CO2 capture and storage technologies, smart energy networks and energy efficiency and savings. Future scenarios for 2030 elaborated by the International Energy Agency (IEA) shows as a mix energy plan could reduce the global CO2 emissions from 27Gt to 23 Gt (about 15%). A strategic use of the underground in terms of: - development of CCS (Carbon dioxide Capture and Storage) associated to fossil fuel combustion; - increase of CH4 geological storage sites; - use of renewable energies as geothermic for power generation; could open a new energy scenario, according to the climate models published by IPCC. Nowadays CCS market is mainly developed in USA and Canada, but still not much accounted in Europe. In Italy there aren't active CCS projects, even if potential areas have been already identified. Many CH4 storage sites are located in Northern America, while other are present in Europe and Italy, but the number of sites is limited despite the huge underground potentiality. In Italy the power generation from geothermal energy comes exclusively from Tuscany (Larderello-Travale and Mt. Amiata geothermal fields) despite the huge potentiality of other regions as Latium, Campania and Sicily (Central and South Italy). The energy deficit and the relevant CO2 emissions represent a common status for many Italian regions, especially for the Latium Region. This suggests that a new energy plan to improve the efficiency and the environmental sustainability is necessary. The evaluations of potential areas suitable for CO2 and/or CH4 geological storage and geothermal energy in the Latium region, have been done through a revisiting of public data such as well composite logs and maps. For the selection has been taken in account too, exclusion criteria sites as well as presence of geological risks and natural protected areas. Then the storage capacity and geothermal potentiality have been estimated for the selected areas. Finally, considering the hypothesized energy mix plan, an evaluation of the potential CO2 emissions decrease has been done. Preliminary results are encouraging to extent this evaluation also in other regions to improve a National Energy Plan.

  13. Hydro pumped storage, international experience: An overview of ASCE task committee report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarechian, A.H.; Rummel, G.

    1995-12-31

    This paper presents an overview of a report that is being prepared by ASCE Task Committee on Pumped Storage, International Experience. The reader is referred to the committee report that will be available in 1996. Many pumped storage projects in Europe, but particularly in Japan are becoming an indispensable resource in management of loads and resources on the electrical system. They serve to enhance reliability of the system and to provide for efficient utilization of thermal resources. Pumped storage is increasingly being used as a system management tool. To serve such purposes and to function in this key role, pumpedmore » storage projects are designed for very fast loading and unloading, for very fast mode reversals from pumping to generating and visa versa, for synchronous generation, and more importantly for load ramping during the pumping mode. This is achieved by use of variable-speed pump turbine units. The use of variable-speed units has proven so successful in Japan that many older projects are retrofitted with this new feature. Other interesting equipment applications are discussed including utilization of multi-stage unregulated pump turbines for very high heads (up to 1,250 m), and continued extension of the experience for high head reversible Francis unit, currently in excess of 750 m.« less

  14. Geohydrology of the High Energy Laser System Test Facility site, White Sands Missile Range, Tularosa Basin, south-central New Mexico

    USGS Publications Warehouse

    Basabilvazo, G.T.; Nickerson, E.L.; Myers, R.G.

    1994-01-01

    The Yesum-HoHoman and Gypsum land (hummocky) soils at the High Energy Laser System Test Facility (HELSTF) represent wind deposits from recently desiccated lacustrine deposits and deposits from the ancestral Lake Otero. The upper 15-20 feet of the subsurface consists of varved gypsiferous clay and silt. Below these surfidai deposits the lithology consists of interbedded clay units, silty-clay units, and fine- to medium-grained quartz arenite units in continuous and discontinuous horizons. Clay horizons can cause perched water above the water table. Analyses of selected clay samples indicate that clay units are composed chiefly of kaolinire and mixed-layer illite/ smectite. The main aquifer is representative of a leaky-confined aquifer. Estimated aquifer properties are: transmissivity (T) = 780 feet squared per day, storage coefficient (S) = 3.1 x 10-3, and hydraulic conductivity (K) = 6.0 feet per day. Ground water flows south and southwest; the estimated hydraulic gradient is 5.3 feet per mile. Analyses of water samples indicate that ground water at the HELSTF site is brackish to slightly saline at the top of the main aquifer. Dissolved-solids concentration near the top of the main aquifer ranges from 5,940 to 11,800 milligrams per liter. Predominant ions are sodium and sulfate. At 815 feet below land surface, the largest dissolved-solids concentration measured is 111,000 milligrams per liter, which indicates increasing salinity with depth. Predominant ions are sodium and chloride.

  15. Method of preparing nuclear wastes for tansportation and interim storage

    DOEpatents

    Bandyopadhyay, Gautam; Galvin, Thomas M.

    1984-01-01

    Nuclear waste is formed into a substantially water-insoluble solid for temporary storage and transportation by mixing the calcined waste with at least 10 weight percent powdered anhydrous sodium silicate to form a mixture and subjecting the mixture to a high humidity environment for a period of time sufficient to form cementitious bonds by chemical reaction. The method is suitable for preparing an interim waste form from dried high level radioactive wastes.

  16. 40 CFR 266.345 - Whom must you notify?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... FACILITIES Conditional Exemption for Low-Level Mixed Waste Storage, Treatment, Transportation and Disposal....340 prior to disposal in order for the waste to remain exempt under the transportation and disposal...

  17. 7 CFR 51.309 - Condition after storage or transit.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (INSPECTION, CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Condition After... which may have developed on apples after they have been in storage or transit shall be considered as...

  18. 7 CFR 51.309 - Condition after storage or transit.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (INSPECTION, CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Condition After... which may have developed on apples after they have been in storage or transit shall be considered as...

  19. Indiscriminate Friendliness in Children Adopted from China to the United States: A Mixed Methods Study

    ERIC Educational Resources Information Center

    Liu, Yanhong; Li, Dan; Xu, Yanqing

    2017-01-01

    Indiscriminate friendliness (IF) is a prominent issue with children adopted from China to the United States. Through a mixed methods design, the authors explored four Chinese adoptees' experiences of IF within their real-life context, investigated potential factors associated with IF, and examined the IF-attachment relationship. This mixed methods…

  20. Do Multiracial Subjects Really Challenge Race?: Mixed-Race Asians in the United States and the Caribbean.

    ERIC Educational Resources Information Center

    Ropp, Steven Masami

    1997-01-01

    Draws on the experiences of people of Asian descent in the United States and the Caribbean to argue that the biological fact of being of mixed race does not reduce the social significance of race. The assumption that racial mixing leads to a raceless society is inaccurate. (SLD)

  1. Geomechanical behavior of the reservoir and caprock system at the In Salah CO2 storage project.

    PubMed

    White, Joshua A; Chiaramonte, Laura; Ezzedine, Souheil; Foxall, William; Hao, Yue; Ramirez, Abelardo; McNab, Walt

    2014-06-17

    Almost 4 million metric tons of CO2 were injected at the In Salah CO2 storage site between 2004 and 2011. Storage integrity at the site is provided by a 950-m-thick caprock that sits above the injection interval. This caprock consists of a number of low-permeability units that work together to limit vertical fluid migration. These are grouped into main caprock units, providing the primary seal, and lower caprock units, providing an additional buffer and some secondary storage capacity. Monitoring observations at the site indirectly suggest that pressure, and probably CO2, have migrated upward into the lower portion of the caprock. Although there are no indications that the overall storage integrity has been compromised, these observations raise interesting questions about the geomechanical behavior of the system. Several hypotheses have been put forward to explain the measured pressure, seismic, and surface deformation behavior. These include fault leakage, flow through preexisting fractures, and the possibility that injection pressures induced hydraulic fractures. This work evaluates these hypotheses in light of the available data. We suggest that the simplest and most likely explanation for the observations is that a portion of the lower caprock was hydrofractured, although interaction with preexisting fractures may have played a significant role. There are no indications, however, that the overall storage complex has been compromised, and several independent data sets demonstrate that CO2 is contained in the confinement zone.

  2. Essays on pricing electricity and electricity derivatives in deregulated markets

    NASA Astrophysics Data System (ADS)

    Popova, Julia

    2008-10-01

    This dissertation is composed of four essays on the behavior of wholesale electricity prices and their derivatives. The first essay provides an empirical model that takes into account the spatial features of a transmission network on the electricity market. The spatial structure of the transmission grid plays a key role in determining electricity prices, but it has not been incorporated into previous empirical models. The econometric model in this essay incorporates a simple representation of the transmission system into a spatial panel data model of electricity prices, and also accounts for the effect of dynamic transmission system constraints on electricity market integration. Empirical results using PJM data confirm the existence of spatial patterns in electricity prices and show that spatial correlation diminishes as transmission lines become more congested. The second essay develops and empirically tests a model of the influence of natural gas storage inventories on the electricity forward premium. I link a model of the effect of gas storage constraints on the higher moments of the distribution of electricity prices to a model of the effect of those moments on the forward premium. Empirical results using PJM data support the model's predictions that gas storage inventories sharply reduce the electricity forward premium when demand for electricity is high and space-heating demand for gas is low. The third essay examines the efficiency of PJM electricity markets. A market is efficient if prices reflect all relevant information, so that prices follow a random walk. The hypothesis of random walk is examined using empirical tests, including the Portmanteau, Augmented Dickey-Fuller, KPSS, and multiple variance ratio tests. The results are mixed though evidence of some level of market efficiency is found. The last essay investigates the possibility that previous researchers have drawn spurious conclusions based on classical unit root tests incorrectly applied to wholesale electricity prices. It is well known that electricity prices exhibit both cyclicity and high volatility which varies through time. Results indicate that heterogeneity in unconditional variance---which is not detected by classical unit root tests---may contribute to the appearance of non-stationarity.

  3. Accelerator-driven Transmutation of Waste

    NASA Astrophysics Data System (ADS)

    Venneri, Francesco

    1998-04-01

    Nuclear waste from commercial power plants contains large quantities of plutonium, other fissionable actinides, and long-lived fission products that are potential proliferation concerns and create challenges for the long-term storage. Different strategies for dealing with nuclear waste are being followed by various countries because of their geologic situations and their views on nuclear energy, reprocessing and non-proliferation. The current United States policy is to store unprocessed spent reactor fuel in a geologic repository. Other countries are opting for treatment of nuclear waste, including partial utilization of the fissile material contained in the spent fuel, prior to geologic storage. Long-term uncertainties are hampering the acceptability and eventual licensing of a geologic repository for nuclear spent fuel in the US, and driving up its cost. The greatest concerns are with the potential for radiation release and exposure from the spent fuel for tens of thousands of years and the possible diversion and use of the actinides contained in the waste for weapons construction. Taking advantage of the recent breakthroughs in accelerator technology and of the natural flexibility of subcritical systems, the Accelerator-driven Transmutation of Waste (ATW) concept offers the United States and other countries the possibility to greatly reduce plutonium, higher actinides and environmentally hazardous fission products from the waste stream destined for permanent storage. ATW does not eliminate the need for, but instead enhances the viability of permanent waste repositories. Far from being limited to waste destruction, the ATW concept also brings to the table new technologies that could be relevant for next-generation power producing reactors. In the ATW concept, spent fuel would be shipped to the ATW site where the plutonium, transuranics and selected long-lived fission products would be destroyed by fission or transmutation in their first and only pass through the facility, using an accelerator-driven subcritical burner cooled by liquid lead/bismuth and limited pyrochemical treatment of the spent fuel and residual waste. This approach contrasts with the present-day practices of aqueous reprocessing (Europe and Japan), in which high purity plutonium is produced and used in the fabrication of fresh mixed oxide fuel (MOX) that is shipped off-site for use in light water reactors.

  4. Potential for a Danish power system using wind energy generators, solar cells and storage

    NASA Astrophysics Data System (ADS)

    Blegaa, S.; Christiansen, G.

    1981-10-01

    Performance characteristics of a combined solar/wind power system equipped with storage and an unspecified back-up power source are studied on the basis of meteorological data in Denmark from 1959-1972. A model for annual production and storage from wind/solar installations is presented, assuming 12% efficiency for the solar cells and various power coefficients of the windmills, in addition to long and short-term storage. Noting that no correlation between wind and solar energy availability was found, and a constant ratio of 60% wind/40% solar was determined to be the optimum mix for large scale power production without taking into consideration the variations among years. It is concluded that 80-90% of the total Danish electrical load can be covered by solar/wind systems, and 100% may be possible with the addition of pumped hydroelectric storage.

  5. Experimental simulation of latent heat thermal energy storage and heat pipe thermal transport for dish concentrator solar receiver

    NASA Technical Reports Server (NTRS)

    Narayanan, R.; Zimmerman, W. F.; Poon, P. T. Y.

    1981-01-01

    Test results on a modular simulation of the thermal transport and heat storage characteristics of a heat pipe solar receiver (HPSR) with thermal energy storage (TES) are presented. The HPSR features a 15-25 kWe Stirling engine power conversion system at the focal point of a parabolic dish concentrator operating at 827 C. The system collects and retrieves solar heat with sodium pipes and stores the heat in NaF-MgF2 latent heat storage material. The trials were run with a single full scale heat pipe, three full scale TES containers, and an air-cooled heat extraction coil to replace the Stirling engine heat exchanger. Charging and discharging, constant temperature operation, mixed mode operation, thermal inertial, etc. were studied. The heat pipe performance was verified, as were the thermal energy storage and discharge rates and isothermal discharges.

  6. Hot Thermal Storage in a Variable Power, Renewable Energy System

    DTIC Science & Technology

    2014-06-01

    vehicle PV photovoltaic SCES super capacitors energy storage SPIDERS Smart Power Infrastructure Demonstration for Energy Reliability TE thermoelectric ...4  Figure 3.  Photovoltaic solar resources of the United States, from [24]. ...........................9  Figure 4.  Annual...collectors, solar photovoltaic collectors and small wind turbines coupled with facility suitable thermal storage systems. D. LITERATURE REVIEW The

  7. 32 CFR Table 4 to Part 855 - Parking and Storage Fees

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Parking and Storage Fees 4 Table 4 to Part 855 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Pt. 855, Table 4 Table 4 to Part 855—Parking and Storage Fees...

  8. 32 CFR Table 4 to Part 855 - Parking and Storage Fees

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Parking and Storage Fees 4 Table 4 to Part 855 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Pt. 855, Table 4 Table 4 to Part 855—Parking and Storage Fees...

  9. 32 CFR Table 4 to Part 855 - Parking and Storage Fees

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Parking and Storage Fees 4 Table 4 to Part 855 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Pt. 855, Table 4 Table 4 to Part 855—Parking and Storage Fees...

  10. 76 FR 24015 - Ryckman Creek Resources, LLC; Notice of Availability of the Environmental Assessment for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... a central gas/liquids separation and storage facility (Ryckman Plant) where all of the pipelines meet, containing oil, water and gas handling, and natural gas liquids (NGL) storage equipment; and it... as the Ryckman Creek (Nugget Unit), into a new interstate natural gas storage field. The Project is...

  11. Triboelectric generators and sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhong Lin; Wang, Sihong; Zhu, Guang

    2017-10-17

    A triboelectric power system includes a triboelectric generator, a rechargeable energy storage unit and a power management circuit. The rechargeable energy storage unit is associated to the triboelectric generator. The power management circuit is configured to receive an input current from the triboelectric generator and to deliver an output current corresponding to the input current to the rechargeable battery so that the output current has a current direction and a voltage that will recharge the rechargeable battery.

  12. Hydrogen-Oxygen PEM Regenerative Fuel Cell Energy Storage System

    NASA Technical Reports Server (NTRS)

    Bents, David J.; Scullin, Vincent J.; Chang, Bei-Jiann; Johnson, Donald W.; Garcia, Christopher P.

    2005-01-01

    An introduction to the closed cycle hydrogen-oxygen polymer electrolyte membrane (PEM) regenerative fuel cell (RFC), recently constructed at NASA Glenn Research Center, is presented. Illustrated with explanatory graphics and figures, this report outlines the engineering motivations for the RFC as a solar energy storage device, the system requirements, layout and hardware detail of the RFC unit at NASA Glenn, the construction history, and test experience accumulated to date with this unit.

  13. Silicon Nanowire/Polymer Hybrid Solar Cell-Supercapacitor: A Self-Charging Power Unit with a Total Efficiency of 10.5.

    PubMed

    Liu, Ruiyuan; Wang, Jie; Sun, Teng; Wang, Mingjun; Wu, Changsheng; Zou, Haiyang; Song, Tao; Zhang, Xiaohong; Lee, Shuit-Tong; Wang, Zhong Lin; Sun, Baoquan

    2017-07-12

    An integrated self-charging power unit, combining a hybrid silicon nanowire/polymer heterojunction solar cell with a polypyrrole-based supercapacitor, has been demonstrated to simultaneously harvest solar energy and store it. By efficiency enhancement of the hybrid nanowire solar cells and a dual-functional titanium film serving as conjunct electrode of the solar cell and supercapacitor, the integrated system is able to yield a total photoelectric conversion to storage efficiency of 10.5%, which is the record value in all the integrated solar energy conversion and storage system. This system may not only serve as a buffer that diminishes the solar power fluctuations from light intensity, but also pave its way toward cost-effective high efficiency self-charging power unit. Finally, an integrated device based on ultrathin Si substrate is demonstrated to expand its feasibility and potential application in flexible energy conversion and storage devices.

  14. Modeling nurses' attitude toward using automated unit-based medication storage and distribution systems: an extension of the technology acceptance model.

    PubMed

    Escobar-Rodríguez, Tomás; Romero-Alonso, María Mercedes

    2013-05-01

    This article analyzes the attitude of nurses toward the use of automated unit-based medication storage and distribution systems and identifies influencing factors. Understanding these factors provides an opportunity to explore actions that might be taken to boost adoption by potential users. The theoretical grounding for this research is the Technology Acceptance Model. The Technology Acceptance Model specifies the causal relationships between perceived usefulness, perceived ease of use, attitude toward using, and actual usage behavior. The research model has six constructs, and nine hypotheses were generated from connections between these six constructs. These constructs include perceived risks, experience level, and training. The findings indicate that these three external variables are related to the perceived ease of use and perceived usefulness of automated unit-based medication storage and distribution systems, and therefore, they have a significant influence on attitude toward the use of these systems.

  15. Research on Power System Scheduling Improving Wind Power Accommodation Considering Thermal Energy Storage and Flexible Load

    NASA Astrophysics Data System (ADS)

    Zou, Chenlu; Cui, Xue; Wang, Heng; Zhou, Bin; Liu, Yang

    2018-01-01

    In the case of rapid development of wind power and heavy wind curtailment, the study of wind power accommodation of combined heat and power system has become the focus of attention. A two-stage scheduling model contains of wind power, thermal energy storage, CHP unit and flexible load were constructed. This model with the objective function of minimizing wind curtailment and the operation cost of units while taking into account of the total coal consumption of units, constraint of thermal energy storage and electricity-heat characteristic of CHP. This paper uses MICA to solve the problem of too many constraints and make the solution more feasible. A numerical example showed that the two stage decision scheduling model can consume more wind power, and it could provide a reference for combined heat and power system short-term operation

  16. The Gothic shale of the Pennsylvanian Paradox Formation Greater Aneth Field (Aneth Unit) Southeastern Utah U.S.A.: Seal for Hydrocarbons and Carbon Dioxide Storage.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heath, Jason E.; Dewers, Thomas; Chidsey, Thomas C.

    Greater Aneth oil field, Utah’s largest oil producer, was discovered in 1956 and has produced over 483 million barrels of oil. Located in the Paradox Basin of southeastern Utah, Greater Aneth is a stratigraphic trap producing from the Pennsylvanian (Desmoinesian) Paradox Formation. Because Greater Aneth is a mature, major oil field in the western U.S., and has a large carbonate reservoir, it was selected to demonstrate combined enhanced oil recovery and carbon dioxide storage. The Aneth Unit in the northwestern part of the field has produced over 160 million barrels of the estimated 386 million barrels of original oil inmore » place—a 42% recovery rate. The large amount of remaining oil made the Aneth Unit ideal to enhance oil recovery by carbon dioxide flooding and demonstrate carbon dioxide storage capacity.« less

  17. Optical storage with electromagnetically induced transparency in cold atoms at a high optical depth

    NASA Astrophysics Data System (ADS)

    Zhang, Shanchao; Zhou, Shuyu; Liu, Chang; Chen, J. F.; Wen, Jianming; Loy, M. M. T.; Wong, G. K. L.; Du, Shengwang

    2012-06-01

    We report experimental demonstration of efficient optical storage with electromagnetically induced transparency (EIT) in a dense cold ^85Rb atomic ensemble trapped in a two-dimensional magneto-optical trap. By varying the optical depth (OD) from 0 to 140, we observe that the optimal storage efficiency for coherent optical pulses has a saturation value of 50% as OD > 50. Our result is consistent with that obtained from hot vapor cell experiments which suggest that a four-wave mixing nonlinear process degrades the EIT storage coherence and efficiency. We apply this EIT quantum memory for narrow-band single photons with controllable waveforms, and obtain an optimal storage efficiency of 49±3% for single-photon wave packets. This is the highest single-photon storage efficiency reported up to today and brings the EIT atomic quantum memory close to practical application because an efficiency of above 50% is necessary to operate the memory within non-cloning regime and beat the classical limit.

  18. Red cell concentrate storage and transport temperature.

    PubMed

    Hancock, V; Cardigan, R; Thomas, S

    2011-10-01

    This study investigated the current U.K. guidelines for storage and transport of red cell concentrates (RCC) in saline, adenine, glucose and mannitol (SAGM). The guidelines stipulate storage at 2-6 °C but allow exposure to between 1-10 °C core temperature in a single occurrence of less than 5 h and a surface temperature of 2-10 °C for no more than 12 h during transportation. Twenty RCC units in SAGM were selected on the day of blood collection (day 0) and in vitro quality was tested pre- and post-temperature deviation at 10 °C and up to day 42 of storage. Each group of 10 RCC units was incubated for either 12 h or for both 5 and 12 h. Haemolysis was below the 0·8% U.K. limit at day 42 in all units, although there was an unexpected trend towards lower haemolysis in packs incubated for 5 and 12 h rather than just 12 h alone. Supernatant potassium was significantly higher than reference data on day 35 (P < 0·05) with a maximum of 58 mmol L(-1) and day 42 (P < 0·001). All units incubated at 10 °C had comparable levels of adenosine triphosphate and, 2,3-diphosphoglycerate to reference data from previous studies, throughout storage. These results suggest that exposure to 10 °C for 12 h or for 5 and 12 h did not adversely affect in vitro red cell quality for the remainder of the components shelf life. © 2011 The Authors. Transfusion Medicine © 2011 British Blood Transfusion Society.

  19. Bioremediation of storage tank bottom sludge by using a two-stage composting system: Effect of mixing ratio and nutrients addition.

    PubMed

    Koolivand, Ali; Rajaei, Mohammad Sadegh; Ghanadzadeh, Mohammad Javad; Saeedi, Reza; Abtahi, Hamid; Godini, Kazem

    2017-07-01

    The effect of mixing ratio and nutrients addition on the efficiency of a two-stage composting system in removal of total petroleum hydrocarbons (TPH) from storage tank bottom sludge (STBS) was investigated. The system consisted of ten windrow piles as primary composting (PC) followed by four in-vessel reactors as secondary composting (SC). Various initial C/N/P and mixing ratios of STBS to immature compost (IC) were examined in the PC and SC for 12 and 6weeks, respectively. The removal rates of TPH in the two-stage system (93.72-95.24%) were higher than those in the single-stage one. Depending on the experiments, TPH biodegradation fitted to the first- and second-order kinetics with the rate constants of 0.051-0.334d -1 and 0.002-0.165gkg -1 d -1 , respectively. The bacteria identified were Pseudomonas sp., Bacillus sp., Klebsiella sp., Staphylococcus sp., and Proteus sp. The study verified that a two-stage composting system is effective in treating the STBS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. New-concept Batteries Based on Aqueous Li+/Na+ Mixed-ion Electrolytes

    PubMed Central

    Chen, Liang; Gu, Qingwen; Zhou, Xufeng; Lee, Saixi; Xia, Yonggao; Liu, Zhaoping

    2013-01-01

    Rechargeable batteries made from low-cost and abundant materials operating in safe aqueous electrolytes are attractive for large-scale energy storage. Sodium-ion battery is considered as a potential alternative of current lithium-ion battery. As sodium-intercalation compounds suitable for aqueous batteries are limited, we adopt a novel concept of Li+/Na+ mixed-ion electrolytes to create two batteries (LiMn2O4/Na0.22MnO2 and Na0.44MnO2/TiP2O7), which relies on two electrochemical processes. One involves Li+ insertion/extraction reaction, and the other mainly relates to Na+ extraction/insertion reaction. Two batteries exhibit specific energy of 17 Wh kg−1 and 25 Wh kg−1 based on the total weight of active electrode materials, respectively. As well, aqueous LiMn2O4/Na0.22MnO2 battery is capable of separating Li+ and Na+ due to its specific mechanism unlike the traditional “rocking-chair” lithium-ion batteries. Hence, the Li+/Na+ mixed-ion batteries offer promising applications in energy storage and Li+/Na+ separation. PMID:23736113

  1. Synergetic Effect of Yolk-Shell Structure and Uniform Mixing of SnS-MoS₂ Nanocrystals for Improved Na-Ion Storage Capabilities.

    PubMed

    Choi, Seung Ho; Kang, Yun Chan

    2015-11-11

    Mixed metal sulfide composite microspheres with a yolk-shell structure for sodium-ion batteries are studied. Tin-molybdenum oxide yolk-shell microspheres prepared by a one-pot spray pyrolysis process transform into yolk-shell SnS-MoS2 composite microspheres. The discharge capacities of the yolk-shell and dense-structured SnS-MoS2 composite microspheres for the 100th cycle are 396 and 207 mA h g(-1), and their capacity retentions measured from the second cycle are 89 and 47%, respectively. The yolk-shell SnS-MoS2 composite microspheres with high structural stability during repeated sodium insertion and desertion processes have low charge-transfer resistance even after long-term cycling. The synergetic effect of the yolk-shell structure and uniform mixing of the SnS and MoS2 nanocrystals result in the excellent sodium-ion storage properties of the yolk-shell SnS-MoS2 composite microspheres by improving their structural stability during cycling.

  2. Tank Pressure Control Experiment on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The tank pressure control experiment is a demonstration of NASA intent to develop new technology for low-gravity management of the cryogenic fluids that will be required for future space systems. The experiment will use freon as the test fluid to measure the effects of jet-induced fluid mixing on storage tank pressure and will produce data on low-gravity mixing processes critical to the design of on-orbit cryogenic storage and resupply systems. Basic data on fluid motion and thermodynamics in low gravity is limited, but such data is critical to the development of space transfer vehicles and spacecraft resupply facilities. An in-space experiment is needed to obtain reliable data on fluid mixing and pressure control because none of the available microgravity test facilities provide a low enough gravity level for a sufficient duration to duplicate in-space flow patterns and thermal processes. Normal gravity tests do not represent the fluid behavior properly; drop-tower tests are limited in length of time available; aircraft low-gravity tests cannot provide the steady near-zero gravity level and long duration needed to study the subtle processes expected in space.

  3. A preliminary study of the deterioration of alder and Douglas-fir chips in outdoor piles.

    Treesearch

    Ernest. Wright

    1954-01-01

    In the fall of 1952, E. E. Matson of the Pacific Northwest Forest and Range Experiment Station learned that the Fir-Tex Insulating Board Company bf St. Helens, Oregon was considering mixing alder with Douglas-fir chips for outside storage. Since alder heartwood i s more susceptible to decay than that of Douglas-fir, the question arose whether mixing the two might...

  4. Goddard Conference on Mass Storage Systems and Technologies, volume 2

    NASA Technical Reports Server (NTRS)

    Kobler, Ben (Editor); Hariharan, P. C. (Editor)

    1993-01-01

    Papers and viewgraphs from the conference are presented. Discussion topics include the IEEE Mass Storage System Reference Model, data archiving standards, high-performance storage devices, magnetic and magneto-optic storage systems, magnetic and optical recording technologies, high-performance helical scan recording systems, and low end helical scan tape drives. Additional discussion topics addressed the evolution of the identifiable unit for processing (file, granule, data set, or some similar object) as data ingestion rates increase dramatically, and the present state of the art in mass storage technology.

  5. Investigating Vertical Mixing Between Two Carbonate Aquifers Using a Multiport Well, Central Texas

    NASA Astrophysics Data System (ADS)

    Kromann, J.; Wong, C. I.; Hunt, B.; Smith, B.; Banner, J. L.

    2011-12-01

    Determining the occurrence and extent of mixing between vertically-adjacent aquifers is critical to dual-aquifer management. This can be challenging due to variable well depths and uncertainty as to hydrostratigraphic sources of groundwater. This study uses a multiport monitor well to investigate the degree of aquifer mixing between the overlying Edwards aquifer and underlying Trinity aquifer in central Texas. The results will inform dual-aquifer management as the Trinity aquifer is being developed as an alternative water source to the Edwards aquifer due to pumping limits and projections of increasing water demand. Water levels from isolated hydrostratigraphic units (n = 19) were measured monthly in the well as climate conditions transitioned from wet to dry (Sept 2010 to May 2011). Groundwater was sampled over a two-week interval in May to June 2011. At the start of the monitoring interval, water levels were high in the Edwards and the uppermost units of the Trinity relative to the rest of the Trinity units. Water levels decreased to lower elevations, from about 635 to 585 ft-msl, under dry conditions. Water levels in the lowermost Trinity declined less, from about 630 to 620 ft-msl, under dry conditions. Two zones separating the Edwards and lowermost Trinity showed almost no head change during this period. The water-level variations between the two aquifers suggest that: i) vertical flow potential from the Edwards to the Trinity occurs during dry conditions, ii) the uppermost stratigraphic units of the Trinity and Edwards are mixing, and iii) portions of the Trinity behave as an aquitard, providing hydrologic separation between the Edwards and lowermost Trinity units. Groundwater samples indicate the presence of three distinct hydrochemical facies: Ca-HCO3 (Edwards), Ca-HCO3-SO4 (lowermost Trinity), and Ca-SO4 (Trinity-Glen Rose Fm), suggesting little vertical flow and mixing. Covariation between groundwater 87Sr/86Sr values and SO4 concentrations from units of the Edwards and lowermost Trinity units can be accounted for by a two-end-member fluid mixing model, which uses a unit from the Edwards and lowermost Trinity as end members. This may indicate that 87Sr/86Sr values and SO4 concentrations are controlled by varying extents of mixing between the two units. Groundwater from units in the Glen Rose Formation (between the Edwards and lowermost Trinity units) cannot be accounted for by this mixing process due to elevated SO4 concentrations likely associated with dissolution of evaporites. 87Sr/86Sr values of evaporites recovered from the well are consistent with 87Sr/86Sr values of groundwater from these Glen Rose units. Although the geochemical model results suggest possible mixing between the Edwards and Trinity aquifers, water-level variations and the presence of distinct hydrochemical facies indicate that vertical flow between the Edwards and Trinity is limited to the uppermost units of the Trinity. This study suggests that the Edwards aquifer and lowermost Trinity units are not likely in hydrologic communication and independent management may be possible.

  6. Experimental study on effects of geologic heterogeneity in enhancing dissolution trapping of supercritical CO2

    NASA Astrophysics Data System (ADS)

    Agartan, Elif; Trevisan, Luca; Cihan, Abdullah; Birkholzer, Jens; Zhou, Quanlin; Illangasekare, Tissa H.

    2015-03-01

    Dissolution trapping is one of the primary mechanisms that enhance the storage security of supercritical carbon dioxide (scCO2) in saline geologic formations. When scCO2 dissolves in formation brine produces an aqueous solution that is denser than formation brine, which leads to convective mixing driven by gravitational instabilities. Convective mixing can enhance the dissolution of CO2 and thus it can contribute to stable trapping of dissolved CO2. However, in the presence of geologic heterogeneities, diffusive mixing may also contribute to dissolution trapping. The effects of heterogeneity on mixing and its contribution to stable trapping are not well understood. The goal of this experimental study is to investigate the effects of geologic heterogeneity on mixing and stable trapping of dissolved CO2. Homogeneous and heterogeneous media experiments were conducted in a two-dimensional test tank with various packing configurations using surrogates for scCO2 (water) and brine (propylene glycol) under ambient pressure and temperature conditions. The results show that the density-driven flow in heterogeneous formations may not always cause significant convective mixing especially in layered systems containing low-permeability zones. In homogeneous formations, density-driven fingering enhances both storage in the deeper parts of the formation and contact between the host rock and dissolved CO2 for the potential mineralization. On the other hand, for layered systems, dissolved CO2 becomes immobilized in low-permeability zones with low-diffusion rates, which reduces the risk of leakage through any fault or fracture. Both cases contribute to the permanence of the dissolved plume in the formation.

  7. Energy Storage Analysis of a Mixed R161/MOF-5 Nanoparticle Nanofluid Based on Molecular Simulations

    PubMed Central

    Wang, Qiang; Tang, Shengli; Li, Leilei

    2018-01-01

    The thermal properties of refrigerants can be modified by adding porous nanoparticles into them. Here, molecular simulations, including molecular dynamics and grand canonical Monte Carlo, were employed to study the thermal energy storage properties of an R161/MOF-5 nanofluid. The results show that the thermodynamic energy change of MOF-5 nanoparticles is linear to the temperature. The adsorption heat calculated by grand canonical Monte Carlo is close to that calculated by the Clausius–Clapeyron equation. Additionally, a negative enhancement of the thermal energy storage capacity of the R161/MOF-5 nanofluid is found near the phase transition area. PMID:29783773

  8. Energy Storage Analysis of a Mixed R161/MOF-5 Nanoparticle Nanofluid Based on Molecular Simulations.

    PubMed

    Wang, Qiang; Tang, Shengli; Li, Leilei

    2018-05-20

    The thermal properties of refrigerants can be modified by adding porous nanoparticles into them. Here, molecular simulations, including molecular dynamics and grand canonical Monte Carlo, were employed to study the thermal energy storage properties of an R161/MOF-5 nanofluid. The results show that the thermodynamic energy change of MOF-5 nanoparticles is linear to the temperature. The adsorption heat calculated by grand canonical Monte Carlo is close to that calculated by the Clausius⁻Clapeyron equation. Additionally, a negative enhancement of the thermal energy storage capacity of the R161/MOF-5 nanofluid is found near the phase transition area.

  9. NREL Screens Universities for Solar and Battery Storage Potential

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    In support of the U.S. Department of Energy's SunShot initiative, NREL provided solar photovoltaic (PV) screenings in 2016 for eight universities seeking to go solar. NREL conducted an initial technoeconomic assessment of PV and storage feasibility at the selected universities using the REopt model, an energy planning platform that can be used to evaluate RE options, estimate costs, and suggest a mix of RE technologies to meet defined assumptions and constraints. NREL provided each university with customized results, including the cost-effectiveness of PV and storage, recommended system size, estimated capital cost to implement the technology, and estimated life cycle costmore » savings.« less

  10. 29 CFR 1926.151 - Fire prevention.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hazardous locations. (5) The nozzle of air, inert gas, and steam lines or hoses, when used in the cleaning... nearest unit shall not exceed 100 feet. (d) Indoor storage. (1) Storage shall not obstruct, or adversely...

  11. 40 CFR 264.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... FACILITIES Hazardous Waste Munitions and Explosives Storage § 264.1202 Closure and post-closure care. (a) At... it remains in service as a munitions or explosives magazine or storage unit. (b) If, after removing...

  12. 40 CFR 264.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... FACILITIES Hazardous Waste Munitions and Explosives Storage § 264.1202 Closure and post-closure care. (a) At... it remains in service as a munitions or explosives magazine or storage unit. (b) If, after removing...

  13. 40 CFR 264.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... FACILITIES Hazardous Waste Munitions and Explosives Storage § 264.1202 Closure and post-closure care. (a) At... it remains in service as a munitions or explosives magazine or storage unit. (b) If, after removing...

  14. 40 CFR 264.1202 - Closure and post-closure care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... FACILITIES Hazardous Waste Munitions and Explosives Storage § 264.1202 Closure and post-closure care. (a) At... it remains in service as a munitions or explosives magazine or storage unit. (b) If, after removing...

  15. Enzyme potentiated desensitisation in treatment of seasonal allergic rhinitis: double blind randomised controlled study.

    PubMed

    Radcliffe, Michael J; Lewith, George T; Turner, Richard G; Prescott, Philip; Church, Martin K; Holgate, Stephen T

    2003-08-02

    To assess the efficacy of enzyme potentiated desensitisation in the treatment of severe summer hay fever poorly controlled by pharmacotherapy. Double blind randomised placebo controlled parallel group study. Hospital in Hampshire. 183 participants aged between 18 and 64 with a history of severe summer hay fever for at least two years; all were skin prick test positive to timothy grass pollen. 90 randomised to active treatment; 93 randomised to placebo. Active treatment: two injections of enzyme potentiated desensitisation, given between eight and 11 weeks apart, each comprising 200 Fishman units of beta glucuronidase, 50 pg 1,3-cyclohexanediol, 50 ng protamine sulphate, and a mixed inhaled allergen extract (pollen mixes for trees, grasses, and weeds; allergenic fungal spores; cat and dog danders; dust and storage mites) in a total volume of 0.05 ml of buffered saline. Placebo: two injections of 0.05 ml buffered saline solution. Proportion of problem-free days; global rhinoconjunctivitis quality of life scores assessed weekly during pollen season. The active treatment group and the placebo group did not differ in the proportion of problem-free days, quality of life scores, symptom severity scores, change in quantitative skin prick provocation threshold, or change in conjunctival provocation threshold. No clinically significant adverse reactions occurred. Enzyme potentiated desensitisation showed no treatment effect in this study.

  16. Development of a prototype thermoelectric space cooling system using phase change material to improve the performance

    NASA Astrophysics Data System (ADS)

    Zhao, Dongliang

    The thermoelectric cooling system has advantages over conventional vapor compression cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no refrigerant, being powered by direct current, and easily switching between cooling and heating modes. However, it has been long suffering from its relatively high cost and low energy efficiency, which has restricted its usage to niche applications, such as space missions, portable cooling devices, scientific and medical equipment, where coefficient of performance (COP) is not as important as reliability, energy availability, and quiet operation environment. Enhancement of thermoelectric cooling system performance generally relies on two methods: improving thermoelectric material efficiency and through thermoelectric cooling system thermal design. This research has been focused on the latter one. A prototype thermoelectric cooling system integrated with phase change material (PCM) thermal energy storage unit for space cooling has been developed. The PCM thermal storage unit used for cold storage at night, functions as the thermoelectric cooling system's heat sink during daytime's cooling period and provides relatively lower hot side temperature for the thermoelectric cooling system. The experimental test of the prototype system in a reduced-scale chamber has realized an average cooling COP of 0.87, with the maximum value of 1.22. Another comparison test for efficacy of PCM thermal storage unit shows that 35.3% electrical energy has been saved from using PCM for the thermoelectric cooling system. In general, PCM faces difficulty of poor thermal conductivity at both solid and liquid phases. This system implemented a finned inner tube to increase heat transfer during PCM charging (melting) process that directly impacts thermoelectric system's performance. A simulation tool for the entire system has been developed including mathematical models for a single thermoelectric module, for the thermoelectric cooling unit, for the PCM thermal storage unit, and for the outdoor air-water heat exchanger. When modeling PCM thermal storage unit, the enthalpy method has been adopted. Since natural convection has been observed in experiments playing a key effect on heat transfer in PCM, a staged effective thermal conductivity (ke) concept and modified Rayleigh (Ra) number formula have been developed to better capture natural convection's variable effects during the PCM charging process. Therefore, a modeling-based design procedure for thermoelectric cooling system integrating with PCM has been proposed. A case study has been completed for a model office room to demonstrate the qualitative and quantitative evaluations to the major system components. Results of this research can be extended to other applications in relevant areas. For instance, the proposed PCM thermal storage unit can be applied to integration with water-cooled conventional air-conditioning devices. Instead of using water cooling, a case study of using the proposed PCM unit for a water-cooled air-conditioner shows a COP increase of more than 25.6%.

  17. Joint physical and numerical modeling of water distribution networks.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmerman, Adam; O'Hern, Timothy John; Orear, Leslie Jr.

    2009-01-01

    This report summarizes the experimental and modeling effort undertaken to understand solute mixing in a water distribution network conducted during the last year of a 3-year project. The experimental effort involves measurement of extent of mixing within different configurations of pipe networks, measurement of dynamic mixing in a single mixing tank, and measurement of dynamic solute mixing in a combined network-tank configuration. High resolution analysis of turbulence mixing is carried out via high speed photography as well as 3D finite-volume based Large Eddy Simulation turbulence models. Macroscopic mixing rules based on flow momentum balance are also explored, and in somemore » cases, implemented in EPANET. A new version EPANET code was developed to yield better mixing predictions. The impact of a storage tank on pipe mixing in a combined pipe-tank network during diurnal fill-and-drain cycles is assessed. Preliminary comparison between dynamic pilot data and EPANET-BAM is also reported.« less

  18. Geologic framework for the national assessment of carbon dioxide storage resources: Hanna, Laramie, and Shirley Basins, Wyoming: Chapter C in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Merrill, Matthew D.; Covault, Jacob A.; Craddock, William H.; Slucher, Ernie R.; Warwick, Peter D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Cahan, Steven M.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.

    2012-01-01

    The 2007 Energy Independence and Security Act (Public Law 110-140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used for the national CO2 assessment is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of twelve storage assessment units (SAUs) in six separate packages of sedimentary rock within the Hanna, Laramie, and Shirley Basins of Wyoming. It focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included herein will be employed, as specified in the methodology, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data in a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.

  19. Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Warwick, Peter D.; Corum, Margo D.

    2012-01-01

    The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2) and to consult with other Federal and State agencies to locate the pertinent geological data needed for the assessment. The geologic sequestration of CO2 is one possible way to mitigate its effects on climate change. The methodology used for the national CO2 assessment (Open-File Report 2010-1127; http://pubs.usgs.gov/of/2010/1127/) is based on previous USGS probabilistic oil and gas assessment methodologies. The methodology is non-economic and intended to be used at regional to subbasinal scales. The operational unit of the assessment is a storage assessment unit (SAU), composed of a porous storage formation with fluid flow and an overlying sealing unit with low permeability. Assessments are conducted at the SAU level and are aggregated to basinal and regional results. This report identifies and contains geologic descriptions of SAUs in separate packages of sedimentary rocks within the assessed basin and focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included here will be employed, as specified in the methodology, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Wells sharing the same well borehole are treated as a single penetration. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.

  20. Energy Storage Systems

    NASA Astrophysics Data System (ADS)

    Elliott, David

    2017-07-01

    As renewable energy use expands there will be a need to develop ways to balance its variability. Storage is one of the options. Presently the main emphasis is for systems storing electrical power in advanced batteries (many of them derivatives of parallel developments in the electric vehicle field), as well as via liquid air storage, compressed air storage, super-capacitors and flywheels, and, the leader so far, pumped hydro reservoirs. In addition, new systems are emerging for hydrogen generation and storage, feeding fuel cell power production. Heat (and cold) is also a storage medium and some systems exploit thermal effects as part of wider energy management activity. Some of the more exotic ones even try to use gravity on a large scale. This short book looks at all the options, their potentials and their limits. There are no clear winners, with some being suited to short-term balancing and others to longer-term storage. The eventual mix adopted will be shaped by the pattern of development of other balancing measures, including smart-grid demand management and super-grid imports and exports.

  1. Twelve Principles for Green Energy Storage in Grid Applications.

    PubMed

    Arbabzadeh, Maryam; Johnson, Jeremiah X; Keoleian, Gregory A; Rasmussen, Paul G; Thompson, Levi T

    2016-01-19

    The introduction of energy storage technologies to the grid could enable greater integration of renewables, improve system resilience and reliability, and offer cost effective alternatives to transmission and distribution upgrades. The integration of energy storage systems into the electrical grid can lead to different environmental outcomes based on the grid application, the existing generation mix, and the demand. Given this complexity, a framework is needed to systematically inform design and technology selection about the environmental impacts that emerge when considering energy storage options to improve sustainability performance of the grid. To achieve this, 12 fundamental principles specific to the design and grid application of energy storage systems are developed to inform policy makers, designers, and operators. The principles are grouped into three categories: (1) system integration for grid applications, (2) the maintenance and operation of energy storage, and (3) the design of energy storage systems. We illustrate the application of each principle through examples published in the academic literature, illustrative calculations, and a case study with an off-grid application of vanadium redox flow batteries (VRFBs). In addition, trade-offs that can emerge between principles are highlighted.

  2. EFFECTS OF RADIATION ON ESTABLISHED FORENSIC EVIDENCE CONTAINMENT METHODS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferguson, C.; Duff, M.; Clark, E.

    2010-11-29

    The Federal Bureau of Investigation (FBI) Laboratory is currently exploring needs and protocols for the storage of evidentiary items contaminated with radioactive material. While a large body of knowledge on the behavior of storage polymers in radiation fields exists, this knowledge has not been applied to the field of forensics and maintaining evidentiary integrity. The focus of this research was to evaluate the behavior of several traditional evidentiary containment polymers when exposed to significant alpha, beta, gamma, neutron and mixed radiation sources. Doses were designed to simulate exposures possible during storage of materials. Several products were found to be poorlymore » suited for use in this specific application based on standardized mechanical testing results. Remaining products were determined to warrant further investigation for the storage of radiologically contaminated evidence.« less

  3. Electricity Storage and the Hydrogen-Chlorine Fuel Cell

    NASA Astrophysics Data System (ADS)

    Rugolo, Jason Steven

    Electricity storage is an essential component of the transforming energy marketplace. Its absence at any significant scale requires that electricity producers sit ready to respond to every flick of a switch, constantly adjusting power production to meet demand. The dispatchable electricity production technologies that currently enable this type of market are growing unpopular because of their carbon emissions. Popular methods to move away from fossil fuels are wind and solar power. These sources also happen to be the least dispatchable. Electricity storage can solve that problem. By overproducing during sunlight to store energy for evening use, or storing during windy periods for delivery in future calm ones, electricity storage has the potential to allow intermittent renewable sources to constitute a large portion of our electricity mix. I investigate the variability of wind in Chapter 2, and show that the variability is not significantly reduced by geographically distributing power production over the entire country of the Netherlands. In Chapter 3, I calculate the required characteristics of a linear-response, constant activity storage technology to map wind and solar production scenarios onto several different supply scenarios for a range of specified system efficiencies. I show that solid electrode batteries have two orders of magnitude too little energy per unit power to be well suited for renewable balancing and emphasize the value of the modular separation between the power and energy components of regenerative fuel cell technologies. In Chapter 4 I introduce the regenerative hydrogen-chlorine fuel cell (rHCFC), which is a specific technology that shows promise for the above applications. In collaboration with Sustainable Innovations, we have made and tested 6 different rHCFCs. In order to understand the relative importance of the different inefficiencies in the rHCFC, Chapter 5 introduces a complex temperature and concentration dependent model of the rHCFC cell potential versus current density. The model identifies the chlorine electrode overpotential as the most important loss for high efficiency operation. In Chapter 6 I develop improved materials for the chlorine electrode and report the discovery of promising conducting metal oxide alloy electrodes, which display high catalytic activity with a small precious metal content.

  4. Effect of Al substitution on the microstructure and lithium storage performance of nickel hydroxide

    NASA Astrophysics Data System (ADS)

    Li, Yanwei; Pan, Guanlin; Xu, Wenqiang; Yao, Jinhuan; Zhang, Lingzhi

    2016-03-01

    Al-substituted Ni(OH)2 samples with Al3+/Ni2+ mole ratio of 0%, 10% and 20% have been prepared by a very facile chemical co-precipitation method. The microstructure of the prepared samples are analyzed by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), thermo-gravimetric analysis (TGA), and Field emission scanning electron microscopy (FESEM). The results reveal that the pure Ni(OH)2 sample is β-Ni(OH)2 with nanosheets hierarchical structure; the sample with 10% Al is mixed phase α/β-Ni(OH)2 with hybrid nanosheets/nanoparticles hierarchical structure; the sample with 20% Al is α-Ni(OH)2 with irregular nanoparticles hierarchical structure. The lithium storage performances of the prepared samples are characterized by cyclic voltammograms (CV), electrochemical impedance spectroscopy (EIS), and charge-discharge tests. The results demonstrate that Al substitution could improve the lithium storage performances of nickel hydroxide. In particular, the mixed phase α/β-Ni(OH)2 with 10% Al exhibited the highest electrochemical activity, the best rate performance, and superior cycling stability. For example, after 30 charge/discharge cycles under a current density of 200 mA g-1, the mixed phase α/β-Ni(OH)2 with 10% Al can still deliver a specific discharge capacity of 964 mAh g-1, much higher than of for the α-Ni(OH)2 with 20% Al (681 mAh g-1) and the pure Ni(OH)2 (419 mAh g-1).

  5. Economic Evaluation of Energy Storage Systems and their Impact on Electricity Markets in a Smart-grid Context

    NASA Astrophysics Data System (ADS)

    Metz, Dennis

    Generation from renewable energy sources has been rising worldwide and is set to grow further, as many countries are implementing and enforcing initiatives to reduce greenhouse gas emission to curb climate change. However, this change in the generation mix is increasingly challenging to handle for the grid operators, as the residual load becomes more volatile and difficult to predict. In order to ensure the continuous balance between supply and demand and minimize the amount of curtailed energy from renewable resources, a range of flexibility options exists. At the consumer end, the flexibility of the load can be increased by demand-side management. Alternatively, by increasing the interconnection capacity, surplus generation can be exchanged with neighboring grid zones. Furthermore, existing generation resources like cogeneration units can be refitted and operated in a more flexible way. Storage, as another flexibility option, has the advantage of being able to act on both demand and supply sides as well as providing a wide range of system services. Hence, during periods with surplus generation from renewable resources, excess supply can be absorbed by storage systems. Contrary, during times with low contribution from renewable generation, the deficit can be compensated by discharging the storage device. However, while storage is well suited from a technological point of view to fill the gap, it remains unclear how the application of a storage device can be monetized. Furthermore, investors are struggling to evaluate potential projects due to their complexity. As a result, current implementations of new storage installations remain behind expectations. In addition, high uncertainty about future developments causes many investors to delay investment decisions. In this context, this work identifies and defines several business cases regarding the integration of storage in power systems. Depending on the intended usage of the storage device, benefits might accrue which cannot be internalized by a private agent. Therefore, only commercial applications for energy storage will be considered. In the following, storage dispatch algorithms and an evaluation framework are developed. This allows defining the benefits that a storage device can provide, including barriers and drivers to its deployment. In order to consider uncertainty in the evaluation process, several assessment methodologies are introduced and adapted to the respective context. Furthermore, the impact of storage systems on the electric grid as well as on electricity markets is analyzed. The results of this research do not only provide a better understanding about potential business cases and related income streams of storage devices to investors, but also provide deep insights into the associated risks of such an investment. Furthermore, the results allow policy makers to identify the relevant parameters for promoting storage in order to facilitate the integration of additional renewable generation capacity. Last, this document gives traditional power producers as well as grid operators a better understanding about the impact of storage installations on generation and demand patterns as well as on the possible impacts on electricity markets. None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tranter, P.

    Tender-assisted drilling (TAD) involves the use of tender support vessel (TSV) during the drilling phase of platform development to provide drilling utilities to the platform-mounted drilling package. The TSV provides facilities such as mud mixing, storage, pumping, bulk storage, hotel accommodations, and power. Thus, the platform topsides and jacket weight and size can be smaller and less expensive. The paper discusses the advantages and disadvantages of TAD, then describes the TAD vessel, semisubmersible, platform cost savings, accommodations, drilling and workovers, and field experience.

  7. Heater-mixer for stored fluids

    NASA Technical Reports Server (NTRS)

    Canning, T. N. (Inventor)

    1974-01-01

    A fluid storage vessel for containing cryogenic fluids is described. The storage vessel contains an auxiliary chamber which is connected to the main container by a jet nozzle. The wall of the auxiliary vessel is heat cycled to produce a corresponding expansion and contraction of the fluid within the auxiliary chamber. This action causes heating and mixing of the stored fluid by means of jetting the expanded fluid to and from relative to the stored fluid contents of the vessel.

  8. Carbon fluxes, storage and harvest removals through 60 years of stand development in red pine plantations and mixed hardwood stands in Northern Michigan, USA

    Treesearch

    Adam Gahagan; Christian P. Giardina; John S. King; Dan Binkley; Kurt S. Pregitzer; Andrew J. Burton

    2015-01-01

    The storage and flow of carbon (C) into and out of forests can differ under the influence of dominant tree species because of species-based variation in C production, decomposition, retention, and harvest-based export. Following abandonment of agricultural activities in the first half of the 20th century, many landscapes of the Great Lakes region (USA) were planted to...

  9. Data Encoding using Periodic Nano-Optical Features

    NASA Astrophysics Data System (ADS)

    Vosoogh-Grayli, Siamack

    Successful trials have been made through a designed algorithm to quantize, compress and optically encode unsigned 8 bit integer values in the form of images using Nano optical features. The periodicity of the Nano-scale features (Nano-gratings) have been designed and investigated both theoretically and experimentally to create distinct states of variation (three on states and one off state). The use of easy to manufacture and machine readable encoded data in secured authentication media has been employed previously in bar-codes for bi-state (binary) models and in color barcodes for multiple state models. This work has focused on implementing 4 states of variation for unit information through periodic Nano-optical structures that separate an incident wavelength into distinct colors (variation states) in order to create an encoding system. Compared to barcodes and magnetic stripes in secured finite length storage media the proposed system encodes and stores more data. The benefits of multiple states of variation in an encoding unit are 1) increased numerically representable range 2) increased storage density and 3) decreased number of typical set elements for any ergodic or semi-ergodic source that emits these encoding units. A thorough investigation has targeted the effects of the use of multi-varied state Nano-optical features on data storage density and consequent data transmission rates. The results show that use of Nano-optical features for encoding data yields a data storage density of circa 800 Kbits/in2 via the implementation of commercially available high resolution flatbed scanner systems for readout. Such storage density is far greater than commercial finite length secured storage media such as Barcode family with maximum practical density of 1kbits/in2 and highest density magnetic stripe cards with maximum density circa 3 Kbits/in2. The numerically representable range of the proposed encoding unit for 4 states of variation is [0 255]. The number of typical set elements for an ergodic source emitting the optical encoding units compared to a bi-state encoding unit (bit) shows a 36 orders of magnitude decrease for the error probability interval of [0 0.01]. The algorithms for the proposed encoding system have been implemented in MATLAB and the Nano-optical structures have been fabricated using Electron Beam Lithography on optical medium.

  10. Improved quality of a vitamin B12-fortified 'ready to blend' fresh-cut mix salad with chitosan.

    PubMed

    Artés-Hernández, Francisco; Formica-Oliveira, Anna Carolina; Artés, Francisco; Martínez-Hernández, Ginés Benito

    2017-09-01

    A vitamin B12-fortified (0.25 mg L -1 ) chitosan (10 g L -1 ) coating was applied to a ready-to-blend fresh-cut salad including melon, pineapple and carrot, which was stored at 5 ℃ up to nine days. Uncoated samples were used as control while the vitamin B12 effect was compared to non-fortified chitosan-coated samples. Beverages were prepared on blending days 0, 4, 7 and 9 with subsequent storage at 5 ℃ for 0, 24 and 48 h. Physicochemical quality of fresh blended beverages was well preserved throughout storage. The chitosan coating highly reduced epiphytic microflora growth and polyphenoloxidase/peroxidase activities. No relevant variations of total phenolic contents were observed between different fresh blended beverages. However, its total antioxidant capacity reported after blending was lower as storage time of ready-to-blend samples increased. Fortified samples showed a vitamin B12 content of 8.6 µg kg -1 on processing day, ensuring 200 mL of such beverage the recommended daily intake of this vitamin. In conclusion, a ready-to-blend fruit/vegetable mix, fortified with vitamin B12, was developed with a shelf life of nine days at 5 ℃ showing the prepared beverages good quality during subsequent storage for 48 h at 5 ℃.

  11. Evaluation of the Effectiveness of Wet Blast Cleaning Methods of Surface Preparation

    DTIC Science & Technology

    1985-06-01

    for Air Abrasive Wet Blast: Complete System Water Abrasive Mixing Chamber in Slurry Blast Unit Schematic of unit Control Unit Slurry Blast — Air/Water...this discussion we present some general. user guidelines regarding what to look for in con- sidering the use or purchase of wet blasting equipment...These units use compressed air as the medium to propel the eroding material. They differ from air abrasive wet blast units in that the abrasive is mixed

  12. Low-level radwaste storage facility at Hope Creek and Salem Generating Stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oyen, L.C.; Lee, K.; Bravo, R.

    Following the January 1, 1993, closure of the radwaste disposal facilities at Beatty, Nevada, and Richland, Washington (to waste generators outside the compact), only Barnwell, South Carolina, is open to waste generators in most states. Barnwell is scheduled to stay open to waste generators outside the Southeast Compact until June 30, 1994. Continued delays in opening regional radwaste disposal facilities have forced most nuclear utilities to consider on-site storage of low-level radwaste. Public Service Electric and Gas Company (PSE G) considered several different radwaste storage options before selecting the design based on the steel-frame and metal-siding building design described inmore » the Electric Power Research Institute's (EPRI's) TR-100298 Vol. 2, Project 3800 report. The storage facility will accommodate waste generated by Salem units 1 and 2 and Hope Creek unit 1 for a 5-yr period and will be located within their common protected area.« less

  13. Unitized regenerative fuel cell system

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A. (Inventor)

    2008-01-01

    A Unitized Regenerative Fuel Cell system uses heat pipes to convey waste heat from the fuel cell stack to the reactant storage tanks. The storage tanks act as heat sinks/sources and as passive radiators of the waste heat from the fuel cell stack. During charge up, i.e., the electrolytic process, gases are conveyed to the reactant storage tanks by way of tubes that include dryers. Reactant gases moving through the dryers give up energy to the cold tanks, causing water vapor in with the gases to condense and freeze on the internal surfaces of the dryer. During operation in its fuel cell mode, the heat pipes convey waste heat from the fuel cell stack to the respective reactant storage tanks, thereby heating them such that the reactant gases, as they pass though the respective dryers on their way to the fuel cell stacks retrieve the water previously removed.

  14. Multiobjective assessment of distributed energy storage location in electricity networks

    NASA Astrophysics Data System (ADS)

    Ribeiro Gonçalves, José António; Neves, Luís Pires; Martins, António Gomes

    2017-07-01

    This paper presents a methodology to provide information to a decision maker on the associated impacts, both of economic and technical nature, of possible management schemes of storage units for choosing the best location of distributed storage devices, with a multiobjective optimisation approach based on genetic algorithms. The methodology was applied to a case study, a known distribution network model in which the installation of distributed storage units was tested, using lithium-ion batteries. The obtained results show a significant influence of the charging/discharging profile of batteries on the choice of their best location, as well as the relevance that these choices may have for the different network management objectives, for example, for reducing network energy losses or minimising voltage deviations. Results also show a difficult cost-effectiveness of an energy-only service, with the tested systems, both due to capital cost and due to the efficiency of conversion.

  15. Material handling robot system for flow-through storage applications

    NASA Astrophysics Data System (ADS)

    Dill, James F.; Candiloro, Brian; Downer, James; Wiesman, Richard; Fallin, Larry; Smith, Ron

    1999-01-01

    This paper describes the design, development and planned implementation of a system of mobile robots for use in flow through storage applications. The robots are being designed with on-board embedded controls so that they can perform their tasks as semi-autonomous workers distributed within a centrally controlled network. On the storage input side, boxes will be identified by bar-codes and placed into preassigned flow through bins. On the shipping side, orders will be forwarded to the robots from a central order processing station and boxes will be picked from designated storage bins following proper sequencing to permit direct loading into trucks for shipping. Because of the need to maintain high system availability, a distributed control strategy has been selected. When completed, the system will permit robots to be dynamically reassigned responsibilities if an individual unit fails. On-board health diagnostics and condition monitoring will be used to maintain high reliability of the units.

  16. Hydrogeologic framework and geologic structure of the Floridan aquifer system and intermediate confining unit in the Lake Okeechobee area, Florida

    USGS Publications Warehouse

    Reese, Ronald S.

    2014-01-01

    The successful implementation of aquifer storage and recovery (ASR) as a water-management tool requires detailed information on the hydrologic and hydraulic properties of the potential water storage zones. This report presents stratigraphic and hydrogeologic sections of the upper part of the Floridan aquifer system and the overlying confining unit or aquifer system in the Lake Okeechobee area, and contour maps of the upper contacts of the Ocala Limestone and the Arcadia Formation, which are represented in the sections. The sections and maps illustrate hydrogeologic factors such as confinement of potential storage zones, the distribution of permeability within the zones, and geologic features that may control the efficiency of injection, storage, and recovery of water, and thus may influence decisions on ASR activities in areas of interest to the Comprehensive Everglades Restoration Plan.

  17. A technique for estimating time of concentration and storage coefficient values for Illinois streams

    USGS Publications Warehouse

    Graf, Julia B.; Garklavs, George; Oberg, Kevin A.

    1982-01-01

    Values of the unit hydrograph parameters time of concentration (TC) and storage coefficient (R) can be estimated for streams in Illinois by a two-step technique developed from data for 98 gaged basins in the State. The sum of TC and R is related to stream length (L) and main channel slope (S) by the relation (TC + R)e = 35.2L0.39S-0.78. The variable R/(TC + R) is not significantly correlated with drainage area, slope, or length, but does exhibit a regional trend. Regional values of R/(TC + R) are used with the computed values of (TC + R)e to solve for estimated values of time of concentration (TCe) and storage coefficient (Re). The use of the variable R/(TC + R) is thought to account for variations in unit hydrograph parameters caused by physiographic variables such as basin topography, flood-plain development, and basin storage characteristics. (USGS)

  18. Ionic liquids, electrolyte solutions including the ionic liquids, and energy storage devices including the ionic liquids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gering, Kevin L.; Harrup, Mason K.; Rollins, Harry W.

    2015-12-08

    An ionic liquid including a phosphazene compound that has a plurality of phosphorus-nitrogen units and at least one pendant group bonded to each phosphorus atom of the plurality of phosphorus-nitrogen units. One pendant group of the at least one pendant group comprises a positively charged pendant group. Additional embodiments of ionic liquids are disclosed, as are electrolyte solutions and energy storage devices including the embodiments of the ionic liquid.

  19. Seasonal Solar Thermal Absorption Energy Storage Development.

    PubMed

    Daguenet-Frick, Xavier; Gantenbein, Paul; Rommel, Mathias; Fumey, Benjamin; Weber, Robert; Gooneseker, Kanishka; Williamson, Tommy

    2015-01-01

    This article describes a thermochemical seasonal storage with emphasis on the development of a reaction zone for an absorption/desorption unit. The heat and mass exchanges are modelled and the design of a suitable reaction zone is explained. A tube bundle concept is retained for the heat and mass exchangers and the units are manufactured and commissioned. Furthermore, experimental results of both absorption and desorption processes are presented and the exchanged power is compared to the results of the simulations.

  20. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit withmore » lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.« less

  1. Stratigraphy of Zambian copperbelt orebodies

    NASA Astrophysics Data System (ADS)

    Binda, Pier L.

    1994-11-01

    The subdivision of the Roan Supergroup in three informal units instead of the traditional Lower Roan/Upper Roan allows a better understanding of facies relationships. The lower division (Siliciclastic Unit) consists of a variable thickness of continental conglomerates and erenites. The middle division (Mixed Unit) consists of a wedge of carbonate and siliciclastic lithologies tapering to the south-west and deposited in a shallow sea. The upper division (Carbonate Unit or Upper Roan s.s.) is a thick succession of dolostones, subordinate argillites and breccias that directly overlies, but is probably in tectonic contact with, the Siliciclastic Unit in the south-western part of the Copperbelt. Reference boundaries for the Mixed and Siliciclastic Units are given for all mining localities of the Zambian Copperbelt. The basal part of the Mixed Unit, host to the most important CuCo orebodies, was deposited during a major marine transgression which, proceeding from SW-NE, swiftly inundated the whole Copperbelt basin. Thus, the Mufulira Ore Formation can be considered as the near-shore facies of the basinal ore shale. The transition from the Mufulira arenites to the Chambishi silty, ore shale has been effaced by erosional or tectonic stripping of the Roan sediments on the Kafue anticline, whereas the transition from silty to carbonaceous ore shale is well documented in the southern part of the Chambishi-Nkana basin. Concomitant with the NE-SW lithofacies changes within the basal Mixed Unit, there is marked decrease in Cu grade and content from the Mufulira wacke and arenite to the silty ore shale of the northern Chambishi basin and the carbonaceous and pyritic ore shale of the southern Chambishi basin. Cobalt is virtually absent in the Mufulira Ore Formation, reaches ore grade in the silty ore shale and occurs in trace amounts in the carbonaceous ore shale. Thus, the correlation of the basal Mixed Unit reveals a hitherto undetected regional metal zoning akin to that noted in parts of individual Copperbelt basin. The middle portion of the Mixed Unit contains at least one laterally continuous Cu mineralization in the arkosic arenite with minor occurrences of local significance. The Siliciclastic Unit contains Cu concentrations at several stratigraphical levels, but precise correlation of footwall orebodies is precluded by the heterogeneity of the clastic wedges of local provenance. The Mixed Unit of the Zambian Copperbelt can be correlated lithostratigraphically with the Serie des Mines of Shaba. A bed-by-bed correlation of the Kamoto (Zaire) and Mindola (Zambia) Ore Formations is proposed. The southern provenance of the Shaba nappes is supported.

  2. Logistics Handbook for Strategic Mobility Planning

    DTIC Science & Technology

    1994-04-01

    tion 83 E. Flatrack Characteristics 85 F. Seashed Characteristics 88 G. Equipment Deployment and Storage Systems (EDSS) 88 H. Palletized Load...Equipment Deployment and Storage Systems (EDSS) 94 41 Containerizable Unit Equipment 97 42 Mobilization Station to Inland Waterway Dock Mileage 101...passengers worldwide, and the DOD Worldwide Personal Property Movement and Storage Program. 15 MTMC also provides interface between military shippers

  3. Identifying Critical Factors in the Cost-Effectiveness of Solar and Battery Storage in Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaren, Joyce A.; Anderson, Katherine H.; Laws, Nicholas D.

    This analysis elucidates the emerging market for distributed solar paired with battery energy storage in commercial buildings across the United States. It provides insight into the near-term and future solar and solar-plus-storage market opportunities as well as the variables that impact the expected savings from installing behind-the-meter systems.

  4. Economic impact of off-line PC viewer for private folder management

    NASA Astrophysics Data System (ADS)

    Song, Koun-Sik; Shin, Myung J.; Lee, Joo Hee; Auh, Yong H.

    1999-07-01

    We developed a PC-based clinical workstation and implemented at Asan Medical Center in Seoul, Korea, Hardwares used were Pentium-II, 8M video memory, 64-128 MB RAM, 19 inch color monitor, and 10/100Mbps network adaptor. One of the unique features of this workstation is management tool for folders reside both in PACS short-term storage unit and local hard disk. Users can copy the entire study or part of the study to local hard disk, removable storages, or CD recorder. Even the images in private folders in PACS short-term storage can be copied to local storage devices. All images are saved as DICOM 3.0 file format with 2:1 lossless compression. We compared the prices of copy films and storage medias considering the possible savings of expensive PACS short- term storage and network traffic. Price savings of copy film is most remarkable in MR exam. Price savings arising from minimal use of short-term unit was 50,000 dollars. It as hard to calculate the price savings arising from the network usage. Off-line PC viewer is a cost-effective way of handling private folder management under the PACS environment.

  5. Proposal for massively parallel data storage system

    NASA Technical Reports Server (NTRS)

    Mansuripur, M.

    1992-01-01

    An architecture for integrating large numbers of data storage units (drives) to form a distributed mass storage system is proposed. The network of interconnected units consists of nodes and links. At each node there resides a controller board, a data storage unit and, possibly, a local/remote user-terminal. The links (twisted-pair wires, coax cables, or fiber-optic channels) provide the communications backbone of the network. There is no central controller for the system as a whole; all decisions regarding allocation of resources, routing of messages and data-blocks, creation and distribution of redundant data-blocks throughout the system (for protection against possible failures), frequency of backup operations, etc., are made locally at individual nodes. The system can handle as many user-terminals as there are nodes in the network. Various users compete for resources by sending their requests to the local controller-board and receiving allocations of time and storage space. In principle, each user can have access to the entire system, and all drives can be running in parallel to service the requests for one or more users. The system is expandable up to a maximum number of nodes, determined by the number of routing-buffers built into the controller boards. Additional drives, controller-boards, user-terminals, and links can be simply plugged into an existing system in order to expand its capacity.

  6. Co-Optimization of CO 2-EOR and Storage Processes in Mature Oil Reservoirs

    DOE PAGES

    Ampomah, William; Balch, Robert S.; Grigg, Reid B.; ...

    2016-08-02

    This article presents an optimization methodology for CO 2 enhanced oil recovery in partially depleted reservoirs. A field-scale compositional reservoir flow model was developed for assessing the performance history of an active CO 2 flood and for optimizing both oil production and CO 2 storage in the Farnsworth Unit (FWU), Ochiltree County, Texas. A geological framework model constructed from geophysical, geological, and engineering data acquired from the FWU was the basis for all reservoir simulations and the optimization method. An equation of state was calibrated with laboratory fluid analyses and subsequently used to predict the thermodynamic minimum miscible pressure (MMP).more » Initial history calibrations of primary, secondary and tertiary recovery were conducted as the basis for the study. After a good match was achieved, an optimization approach consisting of a proxy or surrogate model was constructed with a polynomial response surface method (PRSM). The PRSM utilized an objective function that maximized both oil recovery and CO 2 storage. Experimental design was used to link uncertain parameters to the objective function. Control variables considered in this study included: water alternating gas cycle and ratio, production rates and bottom-hole pressure of injectors and producers. Other key parameters considered in the modeling process were CO 2 purchase, gas recycle and addition of infill wells and/or patterns. The PRSM proxy model was ‘trained’ or calibrated with a series of training simulations. This involved an iterative process until the surrogate model reached a specific validation criterion. A sensitivity analysis was first conducted to ascertain which of these control variables to retain in the surrogate model. A genetic algorithm with a mixed-integer capability optimization approach was employed to determine the optimum developmental strategy to maximize both oil recovery and CO 2 storage. The proxy model reduced the computational cost significantly. The validation criteria of the reduced order model ensured accuracy in the dynamic modeling results. The prediction outcome suggested robustness and reliability of the genetic algorithm for optimizing both oil recovery and CO 2 storage. The reservoir modeling approach used in this study illustrates an improved approach to optimizing oil production and CO 2 storage within partially depleted oil reservoirs such as FWU. Lastly, this study may serve as a benchmark for potential CO 2–EOR projects in the Anadarko basin and/or geologically similar basins throughout the world.« less

  7. Co-Optimization of CO 2-EOR and Storage Processes in Mature Oil Reservoirs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ampomah, William; Balch, Robert S.; Grigg, Reid B.

    This article presents an optimization methodology for CO 2 enhanced oil recovery in partially depleted reservoirs. A field-scale compositional reservoir flow model was developed for assessing the performance history of an active CO 2 flood and for optimizing both oil production and CO 2 storage in the Farnsworth Unit (FWU), Ochiltree County, Texas. A geological framework model constructed from geophysical, geological, and engineering data acquired from the FWU was the basis for all reservoir simulations and the optimization method. An equation of state was calibrated with laboratory fluid analyses and subsequently used to predict the thermodynamic minimum miscible pressure (MMP).more » Initial history calibrations of primary, secondary and tertiary recovery were conducted as the basis for the study. After a good match was achieved, an optimization approach consisting of a proxy or surrogate model was constructed with a polynomial response surface method (PRSM). The PRSM utilized an objective function that maximized both oil recovery and CO 2 storage. Experimental design was used to link uncertain parameters to the objective function. Control variables considered in this study included: water alternating gas cycle and ratio, production rates and bottom-hole pressure of injectors and producers. Other key parameters considered in the modeling process were CO 2 purchase, gas recycle and addition of infill wells and/or patterns. The PRSM proxy model was ‘trained’ or calibrated with a series of training simulations. This involved an iterative process until the surrogate model reached a specific validation criterion. A sensitivity analysis was first conducted to ascertain which of these control variables to retain in the surrogate model. A genetic algorithm with a mixed-integer capability optimization approach was employed to determine the optimum developmental strategy to maximize both oil recovery and CO 2 storage. The proxy model reduced the computational cost significantly. The validation criteria of the reduced order model ensured accuracy in the dynamic modeling results. The prediction outcome suggested robustness and reliability of the genetic algorithm for optimizing both oil recovery and CO 2 storage. The reservoir modeling approach used in this study illustrates an improved approach to optimizing oil production and CO 2 storage within partially depleted oil reservoirs such as FWU. Lastly, this study may serve as a benchmark for potential CO 2–EOR projects in the Anadarko basin and/or geologically similar basins throughout the world.« less

  8. Effects of different storage time on hatching results and some egg quality characteristics of rock partridge (A. graeca) (management and production).

    PubMed

    Günhan, S; Kirikçi, K

    2017-06-01

    In this research, partridge eggs were stored during zero to 7, 8 to 14, 15 to 21, 22 to 28, 29 to 35 and 36 to 42 d, respectively. The effect of different egg storage periods on egg protein and moisture rates, mineral contents, and some egg quality and hatching characteristics were investigated. The extension of egg storage times didn't affect the external quality features like shell weight, shell thickness, and albumen rate, but it affected the yolk weight, yolk index, albumen index, and Haugh unit (P < 0.05). Yolk weight was increased and yolk index, albumen index, and Haugh unit values were decreased with the extension of storage time. Different storage times of partridge eggs did not have important effects on the protein rates. Protein and humidity rate of the eggs were 14.21 and 67.64%, respectively. There were some elements such as S, P, Na, K, and Ca, but Al, Cd, Co, Mo, and Pb could not be found in the partridge eggs. There is no effect of the storage time on the mineral content of the egg. Storage time had negative effect on fertility and hatchability after 21 d of storage d, but no effect on hatchability of fertile eggs. As this study showed, partridge eggs are resistant to long storage times, as partridge egg proteins can resist degradation in the optimum storage times. To determine egg degradation, the study should be focused on partridge eggshell features, which are responsible for degradation. As a result of this research, partridge eggs can be stored for 21 d under optimum storage conditions without any negative hatchability results. © 2017 Poultry Science Association Inc.

  9. Predicting storage-dependent damage to red blood cells using nitrite oxidation kinetics, peroxiredoxin-2 oxidation, and hemoglobin and free heme measurements.

    PubMed

    Oh, Joo-Yeun; Stapley, Ryan; Harper, Victoria; Marques, Marisa B; Patel, Rakesh P

    2015-12-01

    Storage-dependent damage to red blood cells (RBCs) varies significantly. Identifying RBC units that will undergo higher levels of hemolysis during storage may allow for more efficient inventory management decision-making. Oxidative-stress mediates storage-dependent damage to RBCs and will depend on the oxidant:antioxidant balance. We reasoned that this balance or redox tone will serve as a determinant of how a given RBC unit stores and that its assessment in "young" RBCs will predict storage-dependent hemolysis. RBCs were sampled from bags and segments stored for 7 to 42 days. Redox tone was assessed by nitrite oxidation kinetics and peroxiredoxin-2 (Prx-2) oxidation. In parallel, hemolysis was assessed by measuring cell-free hemoglobin (Hb) and free heme (hemin). Correlation analyses were performed to determine if Day 7 measurements predicted either the level of hemolysis at Day 35 or the increase in hemolysis during storage. Higher Day 7 Prx-2 oxidation was associated with higher Day 35 Prx-2 oxidation, suggesting that early assessment of this variable may identify RBCs that will incur the most oxidative damage during storage. RBCs that oxidized nitrite faster on Day 7 were associated with the greatest levels of storage-dependent hemolysis and increases in Prx-2 oxidation. An inverse relationship between storage-dependent changes in oxyhemoglobin and free heme was observed underscoring an unappreciated reciprocity between these molecular species. Moreover, free heme was higher in the bag compared to paired segments, with opposite trends observed for free Hb. Measurement of Prx-2 oxidation and nitrite oxidation kinetics early during RBC storage may predict storage-dependent damage to RBC including hemolysis-dependent formation of free Hb and heme. © 2015 AABB.

  10. Growth of Escherichia coli O157:H7 and Listeria monocytogenes in packaged fresh-cut romaine mix at fluctuating temperatures during commercial transport, retail storage, and display.

    PubMed

    Zeng, Wenting; Vorst, Keith; Brown, Wyatt; Marks, Bradley P; Jeong, Sanghyup; Pérez-Rodríguez, Fernando; Ryser, Elliot T

    2014-02-01

    Temperature abuse during commercial transport and retail sale of leafy greens negatively impacts both microbial safety and product quality. Consequently, the effect of fluctuating temperatures on Escherichia coli O157:H7 and Listeria monocytogenes growth in commercially-bagged salad greens was assessed during transport, retail storage, and display. Over a 16-month period, a series of time-temperature profiles for bagged salads were obtained from five transportation routes covering four geographic regions (432 profiles), as well as during retail storage (4,867 profiles) and display (3,799 profiles). Five different time-temperature profiles collected during 2 to 3 days of transport, 1 and 3 days of retail storage, and 3 days of retail display were then duplicated in a programmable incubator to assess E. coli O157:H7 and L. monocytogenes growth in commercial bags of romaine lettuce mix. Microbial growth predictions using the Koseki-Isobe and McKellar-Delaquis models were validated by comparing the root mean square error (RMSE), bias, and the acceptable prediction zone between the laboratory growth data and model predictions. Monte Carlo simulations were performed to calculate the probability distribution of microbial growth from 8,122,127,472 scenarios during transport, cold room storage, and retail display. Using inoculated bags of retail salad, E. coli O157:H7 and L. monocytogenes populations increased a maximum of 3.1 and 3.0 log CFU/g at retail storage. Both models yielded acceptable RMSEs and biases within the acceptable prediction zone for E. coli O157:H7. Based on the simulation, both pathogens generally increased <2 log CFU/g during transport, storage, and display. However, retail storage duration can significantly impact pathogen growth. This large-scale U.S. study-the first using commercial time/temperature profiles to assess the microbial risk of leafy greens-should be useful in filling some of the data gaps in current risk assessments for leafy greens.

  11. Laminated microchannel devices, mixing units and method of making same

    DOEpatents

    Bennett, Wendy D [Kennewick, WA; Hammerstrom, Donald J [West Richland, WA; Martin, Peter M [Kennewick, WA; Matson, Dean W [Kennewick, WA

    2002-10-17

    A laminated microchannel device is described in which there is a unit operation process layer that has longitudinal channel. The longitudinal channel is cut completely through the layer in which the unit process operation resides. Both the device structure and method of making the device provide significant advantages in terms of simplicity and efficiency. A static mixing unit that can be incorporated in the laminated microchannel device is also described.

  12. A transceiver module of the Mu radar

    NASA Technical Reports Server (NTRS)

    Kato, S.; Ogawa, T.; Tsuda, T.; Sato, T.; Kimura, I.; Fukao, S.

    1983-01-01

    The transceiver (TR) module of a middle and upper atmospheric radar is described. The TR module used in the radar is mainly composed of two units: a mixer (MIX unit) and a power amplifier (PA unit). The former generates the RF wave for transmission and converts the received echo to the IF signal. A 41.5-MHz local signal fed to mixers passes through a digitally controlled 8-bit phase shifter which can change its value up to 1,000 times in a second, so that the MU radar has the ability to steer its antenna direction quickly and flexibly. The MIX unit also contains a buffer amplifier and a gate for the transmitting signal and preamplifier for the received one whose noise figure is less than 5 dB. The PA unit amplifies the RF signal supplied from the MIX unit up to 63.7 dBm (2350 W), and feeds it to the crossed Yagi antenna.

  13. Microbiological and chemical characteristics of Brazilian kefir during fermentation and storage processes.

    PubMed

    Leite, A M O; Leite, D C A; Del Aguila, E M; Alvares, T S; Peixoto, R S; Miguel, M A L; Silva, J T; Paschoalin, V M F

    2013-07-01

    The microbial community composition and chemical characteristics of a Brazilian milk kefir sample produced during its manufacturing and refrigerated storage were investigated by culture-dependent and -independent methods and HPLC. Lactococcus lactis ssp. cremoris and ssp. lactis, Leuconostoc mesenteroides, Acetobacter lovaniensis, and Saccharomyces cerevisiae were isolated, whereas the detected bands on denaturing gel gradient electrophoresis corresponded to Lactobacillus kefiranofaciens, Lactobacillus kefiri, Lactobacillus parakefiri, and S. cerevisiae. After fermentation, lactic acid bacteria were present at levels of 10 log units, whereas acetic acid bacteria and yeast were present at levels of 7.8 and 6 log units, respectively. The lactic acid bacteria and yeast counts remained constant, whereas acetic acid bacteria counts decreased to 7.2 log units during storage. From fermentation to final storage, the pH, lactose content and citric acid of the kefir beverage decreased, followed by an increase in the concentrations of glucose, galactose, ethanol, and lactic, acetic, butyric, and propionic acids. These microbiological and chemical characteristics contribute to the unique taste and aroma of kefir. This research may serve as a basis for the future industrial production of this beverage in Brazil. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Analysis of superconducting magnetic energy storage applications at a proposed wind farm site near Browning, Montana

    NASA Astrophysics Data System (ADS)

    Gaustad, K. L.; Desteese, J. G.

    1993-07-01

    A computer program was developed to analyze the viability of integrating superconducting magnetic energy storage (SMES) with proposed wind farm scenarios at a site near Browning, Montana. The program simulated an hour-by-hour account of the charge/discharge history of a SMES unit for a representative wind-speed year. Effects of power output, storage capacity, and power conditioning capability on SMES performance characteristics were analyzed on a seasonal, diurnal, and hourly basis. The SMES unit was assumed to be charged during periods when power output of the wind resource exceeded its average value. Energy was discharged from the SMES unit into the grid during periods of low wind speed to compensate for below-average output of the wind resource. The option of using SMES to provide power continuity for a wind farm supplemented by combustion turbines was also investigated. Levelizing the annual output of large wind energy systems operating in the Blackfeet area of Montana was found to require a storage capacity too large to be economically viable. However, it appears that intermediate-sized SMES economically levelize the wind energy output on a seasonal basis.

  15. Geologic framework for the national assessment of carbon dioxide storage resources: Bighorn Basin, Wyoming and Montana: Chapter A in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Covault, Jacob A.; Buursink, Mark L.; Craddock, William H.; Merrill, Matthew D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Warwick, Peter D.; Corum, Margo D.

    2012-01-01

    This report identifies and contains geologic descriptions of twelve storage assessment units (SAUs) in six separate packages of sedimentary rocks within the Bighorn Basin of Wyoming and Montana and focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included here will be employed, as specified in the methodology of earlier work, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Wells sharing the same well borehole are treated as a single penetration. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.

  16. Geologic framework for the national assessment of carbon dioxide storage resources: Columbia Basin of Oregon, Washington, and Idaho, and the Western Oregon-Washington basins: Chapter D in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Covault, Jacob A.; Blondes, Madalyn S.; Cahan, Steven M.; DeVera, Christina A.; Freeman, P.A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.

    2013-01-01

    The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows that of previous USGS work. The methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of three storage assessment units (SAUs) in Eocene and Oligocene sedimentary rocks within the Columbia, Puget, Willapa, Astoria, Nehalem, and Willamette Basins of Oregon, Washington, and Idaho, and focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are provided to illustrate geologic factors critical to the assessment. The designated sealing unit in the Columbia Basin is tentatively chosen to be the ubiquitous and thick Miocene Columbia River Basalt Group. As a result of uncertainties regarding the seal integrity of the Columbia River Basalt Group, the SAUs were not quantitatively assessed. Figures in this report show SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on the cell maps.

  17. 40 CFR 264.603 - Post-closure care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES... treatment or storage unit has contaminated soils or ground water that cannot be completely removed or...

  18. 4 CFR 83.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...

  19. 4 CFR 83.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...

  20. 4 CFR 83.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...

  1. RCRA/UST, superfund, and EPCRA hotline training module. Introduction to: Treatment, storage, and disposal facilities (40 CFR parts 264/265, subparts A-E) updated as of July 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-11-01

    The module presents an overview of the general treatment, storage, and disposal facility (TSDF) standards found in 40 CFR parts 264/265, subparts A through E. It identifies and explains each exclusion from parts 264/265, and provides definitions of excluded units, such as wastewater treatment unit and elementary neutralization unit. It locates and describes the requirements for waste analysis and personnel training. It also describes the purpose of a contingency plan and lists the emergency notification procedures. It describes manifest procedures and responsibilities, and lists the unmanifested waste reporting requirements.

  2. Geologic framework for the national assessment of carbon dioxide storage resources: Arkoma Basin, Kansas Basins, and Midcontinent Rift Basin study areas: Chapter F in Geologic framework for the national assessment of carbon dioxide storage resources

    USGS Publications Warehouse

    Buursink, Marc L.; Craddock, William H.; Blondes, Madalyn S.; Freeman, Phillip A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.

    2013-01-01

    2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows that of previous USGS work. This methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of three storage assessment units (SAUs) in Upper Cambrian to Mississippian sedimentary rocks within the Arkoma Basin study area, and two SAUs in Upper Cambrian to Mississippian sedimentary rocks within the Kansas Basins study area. The Arkoma Basin and Kansas Basins are adjacent with very similar geologic units; although the Kansas Basins area is larger, the Arkoma Basin is more structurally complex. The report focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in the SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are usually provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information herein was employed, as specified in the USGS methodology, to calculate a probabilistic distribution of potential storage resources in each SAU. The Midcontinent Rift Basin study area was not assessed, because no suitable storage formations meeting our size, depth, reservoir quality, and regional seal guidelines were found. Figures in this report show study area boundaries along with the SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one-square mile and are derived from interpretations of incompletely attributed well data and from a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on the cell maps.

  3. Telemetry data storage systems technology for the Space Station Freedom era

    NASA Technical Reports Server (NTRS)

    Dalton, John T.

    1989-01-01

    This paper examines the requirements and functions of the telemetry-data recording and storage systems, and the data-storage-system technology projected for the Space Station, with particular attention given to the Space Optical Disk Recorder, an on-board storage subsystem based on 160 gigabit erasable optical disk units each capable of operating at 300 M bits per second. Consideration is also given to storage systems for ground transport recording, which include systems for data capture, buffering, processing, and delivery on the ground. These can be categorized as the first in-first out storage, the fast random-access storage, and the slow access with staging. Based on projected mission manifests and data rates, the worst case requirements were developed for these three storage architecture functions. The results of the analysis are presented.

  4. How much electrical energy storage do we need? A synthesis for the U.S., Europe, and Germany

    DOE PAGES

    Cebulla, Felix; Haas, Jannik; Eichman, Josh; ...

    2018-02-03

    Electrical energy storage (EES) is a promising flexibility source for prospective low-carbon energy systems. In the last couple of years, many studies for EES capacity planning have been produced. However, these resulted in a very broad range of power and energy capacity requirements for storage, making it difficult for policymakers to identify clear storage planning recommendations. Therefore, we studied 17 recent storage expansion studies pertinent to the U.S., Europe, and Germany. We then systemized the storage requirement per variable renewable energy (VRE) share and generation technology. Our synthesis reveals that with increasing VRE shares, the EES power capacity increases linearly;more » and the energy capacity, exponentially. Further, by analyzing the outliers, the EES energy requirements can be at least halved. It becomes clear that grids dominated by photovoltaic energy call for more EES, while large shares of wind rely more on transmission capacity. Taking into account the energy mix clarifies - to a large degree - the apparent conflict of the storage requirements between the existing studies. Finally, there might exist a negative bias towards storage because transmission costs are frequently optimistic (by neglecting execution delays and social opposition) and storage can cope with uncertainties, but these issues are rarely acknowledged in the planning process.« less

  5. How much electrical energy storage do we need? A synthesis for the U.S., Europe, and Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cebulla, Felix; Haas, Jannik; Eichman, Josh

    Electrical energy storage (EES) is a promising flexibility source for prospective low-carbon energy systems. In the last couple of years, many studies for EES capacity planning have been produced. However, these resulted in a very broad range of power and energy capacity requirements for storage, making it difficult for policymakers to identify clear storage planning recommendations. Therefore, we studied 17 recent storage expansion studies pertinent to the U.S., Europe, and Germany. We then systemized the storage requirement per variable renewable energy (VRE) share and generation technology. Our synthesis reveals that with increasing VRE shares, the EES power capacity increases linearly;more » and the energy capacity, exponentially. Further, by analyzing the outliers, the EES energy requirements can be at least halved. It becomes clear that grids dominated by photovoltaic energy call for more EES, while large shares of wind rely more on transmission capacity. Taking into account the energy mix clarifies - to a large degree - the apparent conflict of the storage requirements between the existing studies. Finally, there might exist a negative bias towards storage because transmission costs are frequently optimistic (by neglecting execution delays and social opposition) and storage can cope with uncertainties, but these issues are rarely acknowledged in the planning process.« less

  6. THERMOCHEMICAL HEAT STORAGE FOR CONCENTRATED SOLAR POWER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PROJECT STAFF

    2011-10-31

    Thermal energy storage (TES) is an integral part of a concentrated solar power (CSP) system. It enables plant operators to generate electricity beyond on sun hours and supply power to the grid to meet peak demand. Current CSP sensible heat storage systems employ molten salts as both the heat transfer fluid and the heat storage media. These systems have an upper operating temperature limit of around 400 C. Future TES systems are expected to operate at temperatures between 600 C to 1000 C for higher thermal efficiencies which should result in lower electricity cost. To meet future operating temperature andmore » electricity cost requirements, a TES concept utilizing thermochemical cycles (TCs) based on multivalent solid oxides was proposed. The system employs a pair of reduction and oxidation (REDOX) reactions to store and release heat. In the storage step, hot air from the solar receiver is used to reduce the oxidation state of an oxide cation, e.g. Fe3+ to Fe2+. Heat energy is thus stored as chemical bonds and the oxide is charged. To discharge the stored energy, the reduced oxide is re-oxidized in air and heat is released. Air is used as both the heat transfer fluid and reactant and no storage of fluid is needed. This project investigated the engineering and economic feasibility of this proposed TES concept. The DOE storage cost and LCOE targets are $15/kWh and $0.09/kWh respectively. Sixteen pure oxide cycles were identified through thermodynamic calculations and literature information. Data showed the kinetics of re-oxidation of the various oxides to be a key barrier to implementing the proposed concept. A down selection was carried out based on operating temperature, materials costs and preliminary laboratory measurements. Cobalt oxide, manganese oxide and barium oxide were selected for developmental studies to improve their REDOX reaction kinetics. A novel approach utilizing mixed oxides to improve the REDOX kinetics of the selected oxides was proposed. It partially replaces some of the primary oxide cations with selected secondary cations. This causes a lattice charge imbalance and increases the anion vacancy density. Such vacancies enhance the ionic mass transport and lead to faster re-oxidation. Reoxidation fractions of Mn3O4 to Mn2O3 and CoO to Co3O4 were improved by up to 16 fold through the addition of a secondary oxide. However, no improvement was obtained in barium based mixed oxides. In addition to enhancing the short term re-oxidation kinetics, it was found that the use of mixed oxides also help to stabilize or even improve the TES properties after long term thermal cycling. Part of this improvement could be attributed to a reduced grain size in the mixed oxides. Based on the measurement results, manganese-iron, cobalt-aluminum and cobalt iron mixed oxides have been proposed for future engineering scale demonstration. Using the cobalt and manganese mixed oxides, we were able to demonstrate charge and discharge of the TES media in both a bench top fixed bed and a rotary kiln-moving bed reactor. Operations of the fixed bed configuration are straight forward but require a large mass flow rate and higher fluid temperature for charging. The rotary kiln makes direct solar irradiation possible and provides significantly better heat transfer, but designs to transport the TES oxide in and out of the reactor will need to be defined. The final reactor and system design will have to be based on the economics of the CSP plant. A materials compatibility study was also conducted and it identified Inconel 625 as a suitable high temperature engineering material to construct a reactor holding either cobalt or manganese mixed oxides. To assess the economics of such a CSP plant, a packed bed reactor model was established as a baseline. Measured cobalt-aluminum oxide reaction kinetics were applied to the model and the influences of bed properties and process parameters on the overall system design were investigated. The optimal TES system design was found to be a network of eight fixed bed reactors at 18.75 MWth each with charge and discharge temperatures between 1200 C and 600 C, which provides a constant output temperature of 900 C. The charge and discharge time are 8 hours each respectively. This design was integrated into a process flowsheet of a CSP plant and the system's economics were determined using AspenPlus and NREL's Solar Advisory Model. Storage cost is very sensitive to materials cost and was calculated to be based around $40/kWh for cobalt based mixed oxide. It can potentially decrease to $10/kWh based on reduced materials cost on a bulk scale. The corresponding calculated LCOE was between $0.22 and 0.30/kW-h. The high LCOE is a result of the high charging temperature required in this first design and the cost of cobalt oxide. It is expected that a moving bed reactor using manganese oxide will significantly improve the economics of the proposed concept.« less

  7. Mixing soil samples across experimental units ignores uncertainty and generates falsely precise estimates of soil biota effects on plants

    USDA-ARS?s Scientific Manuscript database

    A number of recent soil biota studies have deviated from the standard experimental approach of generating a distinct data value for each experimental unit (e.g. Yang et al., 2013; Gundale et al., 2014). Instead, these studies have mixed together soils from multiple experimental units (i.e. sites wi...

  8. Effect of sodium lactate as cryostabilizer on physico-chemical attributes of croaker (Johnius gangeticus) muscle protein.

    PubMed

    Dey, S S; Dora, K C

    2010-08-01

    Effect of sodium lactate as cryostabilizer on physico-chemical attributes of croaker (Johnius gangeticus) fish muscle protein was studied during freezing and frozen (-20 ± 2°C) storage for 3 months. Minced meat was mixed with 4% sucrose, 4% sorbitol, and 0.3% sodium tri poly phosphate (STPP) (T1), minced meat was mixed with 6% (w/v) sodium lactate and 0.3% STPP (T2) and control (C) was without any additive. The decreasing rate of Ca(2+) ATPase activity, thaw drip, water holding capacity and relative viscosity in T1 and T2 samples from that of C was significantly lower, indicating higher protective effect of additives. In case of cryoprotectant treated samples, the degradation of myosin heavy chain was much lower than that of C which prevents the aggregation and subsequent insolubilization of myosin during frozen storage. The sodium lactate prevented Ca(2+)ATPase activity more than that of sucrose/sorbitol during isothermal storage at -20 ± 2°C for 3 months. This inferred that sodium lactate can effectively be used as an alternative cryostabilizer to sucrose/sorbitol for stabilization of croaker muscle protein native structure.

  9. Project Themis Supercritical Cold Flow Facility, Experiment Design and Modeling for the Study of Fluid Mixing

    DTIC Science & Technology

    2012-06-01

    AFRL facility was well suited for the Themis cold flow experiment. A test cell was selected that contained an insulated cryogenic oxygen tank that...could be used for the LN2 supply. Adjacent to the test cell is a cryogenic storage bunker that contained a helium supply tank with existing high...venturi to the fuel bunker tank was very low (less than 25 psi) while the helium pressure drop from the cryogenic storage bunker was almost 2000 psi

  10. Granulated lead oxides with teflon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nilsson, O.

    An improvement in the production of tube electrodes for lead storage batteries comprising mixing a small amount (0.1 to 3 weight percent) of polytetrafluoroethylene (Ptfe) with lead powder, the mixture is heated and shear stresses are applied thereto sufficient to convert substantially all of the ptfe in the mixture to fibrous form and to form a non-powdery dough. The dough is then granulated and the doughy granules about 100 mu to 500 mu in major dimension are used for filling tube elctrodes a lead-acid storage battery.

  11. Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Qin; Martinez-Anido, Carlo Brancucci; Wu, Hongyu

    Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economicmore » dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.« less

  12. Through-Space Intervalence Charge Transfer as a Mechanism for Charge Delocalisation in Metal-Organic Frameworks.

    PubMed

    Hua, Carol; Doheny, Patrick William; Ding, Bowen; Chan, Bun; Yu, Michelle; Kepert, Cameron J; D'Alessandro, Deanna M

    2018-05-04

    Understanding the nature of charge transfer mechanisms in 3-dimensional Metal-Organic Frameworks (MOFs) is an important goal owing to the possibility of harnessing this knowledge to design conductive frameworks. These materials have been implicated as the basis for the next generation of technological devices for applications in energy storage and conversion, including electrochromic devices, electrocatalysts, and battery materials. After nearly two decades of intense research into MOFs, the mechanisms of charge transfer remain relatively poorly understood, and new strategies to achieve charge mobility remain elusive and challenging to experimentally explore, validate and model. We now demonstrate that aromatic stacking interactions in Zn(II) frameworks containing cofacial thiazolo[5,4-d]thiazole units lead to a mixed-valence state upon electrochemical or chemical reduction. This through-space Intervalence Charge Transfer (IVCT) phenomenon represents a new mechanism for charge delocalisation in MOFs. Computational modelling of the optical data combined with application of Marcus-Hush theory to the IVCT bands for the mixed-valence framework has enabled quantification of the degree of delocalisation using both in situ and ex situ electro- and spectro-electrochemical methods. A distance dependence for the through-space electron transfer has also been identified on the basis of experimental studies and computational calculations. This work provides a new window into electron transfer phenomena in 3-dimensional coordination space, of relevance to electroactive MOFs where new mechanisms for charge transfer are highly sought after, and to understanding biological light harvesting systems where through-space mixed-valence interactions are operative.

  13. 40 CFR 63.1275 - Glycol dehydration unit process vent standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...

  14. 40 CFR 63.1275 - Glycol dehydration unit process vent standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...

  15. Manned maneuvering unit technology survey

    NASA Technical Reports Server (NTRS)

    Cook, G. V. O. (Editor)

    1975-01-01

    The preliminary design of the manned maneuvering unit (MMU) for the shuttle is investigated, and the current state of the art in certain technology areas that may find application on the operational EVA shuttle MMU is examined. Three broad areas of technology, namely: (1) mechanical energy storage - i.e., the practicality of utilizing the energy storage capability of either a reaction wheel or a control moment gyro, (2) numerical and alphanumerical displays, and (3) recent electronics developments such as microprocessors and integrated injection logic, were covered.

  16. Cryogenic Propellant Storage and Transfer Engineering Development Unit Hydrogen Tank

    NASA Technical Reports Server (NTRS)

    Werkheiser, Arthur

    2015-01-01

    The Cryogenic Propellant Storage and Transfer (CPST) project has been a long-running program in the Space Technology Mission Directorate to enhance the knowledge and technology related to handling cryogenic propellants, specifically liquid hydrogen. This particular effort, the CPST engineering development unit (EDU), was a proof of manufacturability effort in support of a flight article. The EDU was built to find and overcome issues related to manufacturability and collect data to anchor the thermal models for use on the flight design.

  17. Conception and construction of an LPG tank using a composite membrane technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuvel, P.; Claude, J.

    TECHNIGAZ and TOTAL C.F.P. have developed a new LPG storage technology derived from the membrane concept used for LNG storage and transportation. This technology called GMS uses a composite membrane as primary barrier. A 2 000 m/sup 3/ storage pilot unit, based on that concept, is under construction in TOTAL's refinery at DUNKIRK (France) since September 1983.

  18. Silver Nanoparticle Storage Stability in Aqueous and Biological Media

    DTIC Science & Technology

    2015-06-22

    silver nanoparticle stability from the point of synthesis to the point of testing. The recommended conditions of water storage at 4°C protected from... silver nanoparticle formulation for fabrication. (Report No. 2014-73). 13 Métraux, G. S. & Mirkin, C. A. Rapid thermal synthesis of silver ...NAVAL MEDICAL RESEARCH UNIT SAN ANTONIO SILVER NANOPARTICLE STORAGE STABILITY IN AQUEOUS AND BIOLOGICAL MEDIA NATALIE A

  19. Justification of Estimates for Fiscal Year 1983 Submitted to Congress.

    DTIC Science & Technology

    1982-02-01

    hierarchies to aid software production; completion of the components of an adaptive suspension vehicle including a storage energy unit, hydraulics, laser...and corrosion (long storage times), and radiation-induced breakdown. Solid- lubricated main engine bearings for cruise missile engines would offer...environments will cause "soft error" (computational and memory storage errors) in advanced microelectronic circuits. Research on high-speed, low-power

  20. Functional mixed effects spectral analysis

    PubMed Central

    KRAFTY, ROBERT T.; HALL, MARTICA; GUO, WENSHENG

    2011-01-01

    SUMMARY In many experiments, time series data can be collected from multiple units and multiple time series segments can be collected from the same unit. This article introduces a mixed effects Cramér spectral representation which can be used to model the effects of design covariates on the second-order power spectrum while accounting for potential correlations among the time series segments collected from the same unit. The transfer function is composed of a deterministic component to account for the population-average effects and a random component to account for the unit-specific deviations. The resulting log-spectrum has a functional mixed effects representation where both the fixed effects and random effects are functions in the frequency domain. It is shown that, when the replicate-specific spectra are smooth, the log-periodograms converge to a functional mixed effects model. A data-driven iterative estimation procedure is offered for the periodic smoothing spline estimation of the fixed effects, penalized estimation of the functional covariance of the random effects, and unit-specific random effects prediction via the best linear unbiased predictor. PMID:26855437

Top