Comparative study on the welded structure fatigue strength assessment method
NASA Astrophysics Data System (ADS)
Hu, Tao
2018-04-01
Due to the welding structure is widely applied in various industries, especially the pressure container, motorcycle, automobile, aviation, ship industry, such as large crane steel structure, so for welded structure fatigue strength evaluation is particularly important. For welded structure fatigue strength evaluation method mainly has four kinds of, the more from the use of two kinds of welded structure fatigue strength evaluation method, namely the nominal stress method and the hot spot stress evaluation method, comparing from its principle, calculation method for the process analysis and research, compare the similarities and the advantages and disadvantages, the analysis of practical engineering problems to provide the reference for every profession and trade, as well as the future welded structure fatigue strength and life evaluation method put forward outlook.
Aeroelastic loads prediction for an arrow wing. Task 1: Evaluation of R. P. White's method
NASA Technical Reports Server (NTRS)
Borland, C. J.; Manro, M. E.
1983-01-01
The separated flow method is evaluated. This method was developed for moderately swept wings with multiple, constant strength vortex systems. The flow on the highly swept wing used in this evaluation is characterized by a single vortex system of continuously varying strength.
BTC method for evaluation of remaining strength and service life of bridge cables.
DOT National Transportation Integrated Search
2011-09-01
"This report presents the BTC method; a comprehensive state-of-the-art methodology for evaluation of remaining : strength and residual life of bridge cables. The BTC method is a probability-based, proprietary, patented, and peerreviewed : methodology...
Ultrasonic evaluation of the strength of unidirectional graphite-polyimide composites
NASA Technical Reports Server (NTRS)
Vary, A.; Bowles, K. J.
1977-01-01
An acoustic-ultrasonic method is described that was successful in ranking unidirectional graphite-polyimide composite specimens according to variations in interlaminar shear strength. Using this method, a quantity termed the stress wave factor was determined. It was found that this factor increases directly with interlaminar shear strength. The key variables in this investigation were composite density, fiber weight fraction, and void content. The stress wave factor and other ultrasonic factors that were studied were found to provide a powerful means for nondestructive evaluation of mechanical strength properties.
Reliability of Hull Girder Ultimate Strength of Steel Ships
NASA Astrophysics Data System (ADS)
Da-wei, Gao; Gui-jie, Shi
2018-03-01
Hull girder ultimate strength is an evaluation index reflecting the true safety margin or structural redundancy about container ships. Especially, after the hull girder fracture accident of the MOL COMFORT, the 8,000TEU class large container ship, on June 17 2013, larger container ship safety has been paid on much more attention. In this paper, different methods of calculating hull girder ultimate strength are firstly discussed and compared with. The bending ultimate strength can be analyzed by nonlinear finite element method (NFEM) and increment-iterative method, and also the shear ultimate strength can be analyzed by NFEM and simple equations. Then, the probability distribution of hull girder wave loads and still water loads of container ship are summarized. At last, the reliability of hull girder ultimate strength under bending moment and shear forces for three container ships is analyzed by using a first order method. The conclusions can be applied to give guidance for ship design and safety evaluation.
Core strength training for patients with chronic low back pain.
Chang, Wen-Dien; Lin, Hung-Yu; Lai, Ping-Tung
2015-03-01
[Purpose] Through core strength training, patients with chronic low back pain can strengthen their deep trunk muscles. However, independent training remains challenging, despite the existence of numerous core strength training strategies. Currently, no standardized system has been established analyzing and comparing the results of core strength training and typical resistance training. Therefore, we conducted a systematic review of the results of previous studies to explore the effectiveness of various core strength training strategies for patients with chronic low back pain. [Methods] We searched for relevant studies using electronic databases. Subsequently, we evaluated their quality by analyzing the reported data. [Results] We compared four methods of evaluating core strength training: trunk balance, stabilization, segmental stabilization, and motor control exercises. According to the results of various scales and evaluation instruments, core strength training is more effective than typical resistance training for alleviating chronic low back pain. [Conclusion] All of the core strength training strategies examined in this study assist in the alleviation of chronic low back pain; however, we recommend focusing on training the deep trunk muscles to alleviate chronic low back pain.
DOT National Transportation Integrated Search
2008-01-01
This research involved a detailed laboratory study of a new test method for evaluating road base materials based on : the strength of the soil binder. In this test method, small test specimens (5.0in length and 0.75in square cross : section) of binde...
A Strengths-Based Group Intervention for Women Who Experienced Child Sexual Abuse
ERIC Educational Resources Information Center
Walker-Williams, Hayley J.; Fouché, Ansie
2017-01-01
Purpose: This study evaluated the benefits of a ''survivor to thriver'' strengths-based group intervention program to facilitate posttraumatic growth in women survivors of child sexual abuse. Method: A quasi-experimental, one group, pretest, posttest, time-delay design was employed using qualitative methods to evaluate the benefits of the…
Quantitative Ultrasonic Evaluation of Mechanical Properties of Engineering Materials
NASA Technical Reports Server (NTRS)
Vary, A.
1978-01-01
Progress in the application of ultrasonic techniques to nondestructive measurement of mechanical strength of engineering materials is reviewed. A dormant concept in nondestructive evaluation (NDE) is invoked. The availability of ultrasonic methods that can be applied to actual parts to assess their potential susceptibility to failure under design conditions is discussed. It was shown that ultrasonic methods yield measurements of elastic moduli, microstructure, hardness, fracture toughness, tensile strength, yield strength, and shear strength for a wide range of materials (including many types of metals, ceramics, and fiber composites). It was also indicated that although most of these methods were shown feasible in laboratory studies, more work is needed before they can be used on actual parts in processing, assembly, inspection, and maintenance lines.
Strength evaluation test of pressureless-sintered silicon nitride at room temperature
NASA Technical Reports Server (NTRS)
Matsusue, K.; Takahara, K.; Hashimoto, R.
1984-01-01
In order to study strength characteristics at room temperature and the strength evaluating method of ceramic materials, the following tests were conducted on pressureless sintered silicon nitride specimens: bending tests, the three tensile tests of rectangular plates, holed plates, and notched plates, and spin tests of centrally holed disks. The relationship between the mean strength of specimens and the effective volume of specimens are examined using Weibull's theory. The effect of surface grinding on the strength of specimens is discussed.
NASA Astrophysics Data System (ADS)
Masuyama, Tomoya; Inoue, Katsumi; Yamanaka, Masashi; Kitamura, Kenichi; Saito, Tomoyuki
High load capacity of carburized gears originates mainly from the hardened layer and induced residual stress. On the other hand, surface decarburization, which causes a nonmartensitic layer, and inclusions such as oxides and segregation act as latent defects which considerably reduce fatigue strength. In this connection, the authors have proposed a formula of strength evaluation by separately quantifying defect influence. However, the principal defect which limits strength of gears with several different defects remains unclarified. This study presents a method of inferential identification of principal defects based on test results of carburized gears made of SCM420 clean steel, gears with both an artificial notch and nonmartensitic layer at the tooth fillet, and so forth. It clarifies practical uses of presented methods, and strength of carburized gears can be evaluated by focusing on principal defect size.
Proceedings of the Second Annual Symposium for Nondestructive Evaluation of Bond Strength
NASA Technical Reports Server (NTRS)
Roberts, Mark J. (Compiler)
1999-01-01
Ultrasonics, microwaves, optically stimulated electron emission (OSEE), and computational chemistry approaches have shown relevance to bond strength determination. Nonlinear ultrasonic nondestructive evaluation methods, however, have shown the most effectiveness over other methods on adhesive bond analysis. Correlation to changes in higher order material properties due to microstructural changes using nonlinear ultrasonics has been shown related to bond strength. Nonlinear ultrasonic energy is an order of magnitude more sensitive than linear ultrasound to these material parameter changes and to acoustic velocity changes caused by the acoustoelastic effect when a bond is prestressed. Signal correlations between non-linear ultrasonic measurements and initialization of bond failures have been measured. This paper reviews bond strength research efforts presented by university and industry experts at the Second Annual Symposium for Nondestructive Evaluation of Bond Strength organized by the NDE Sciences Branch at NASA Langley in November 1998.
Karl Romstad
1964-01-01
Methods of obtaining strength and elastic properties of plastic laminates reinforced with unwoven glass fibers were evaluated using the criteria of the strength values obtained and the failure characteristics observed. Variables investigated were specimen configuration and the manner of supporting and loading the specimens. Results of this investigation indicate that...
Objective Evaluation of Muscle Strength in Infants with Hypotonia and Muscle Weakness
ERIC Educational Resources Information Center
Reus, Linda; van Vlimmeren, Leo A.; Staal, J. Bart; Janssen, Anjo J. W. M.; Otten, Barto J.; Pelzer, Ben J.; Nijhuis-van der Sanden, Maria W. G.
2013-01-01
The clinical evaluation of an infant with motor delay, muscle weakness, and/or hypotonia would improve considerably if muscle strength could be measured objectively and normal reference values were available. The authors developed a method to measure muscle strength in infants and tested 81 typically developing infants, 6-36 months of age, and 17…
Objective evaluation of muscle strength in infants with hypotonia and muscle weakness.
Reus, Linda; van Vlimmeren, Leo A; Staal, J Bart; Janssen, Anjo J W M; Otten, Barto J; Pelzer, Ben J; Nijhuis-van der Sanden, Maria W G
2013-04-01
The clinical evaluation of an infant with motor delay, muscle weakness, and/or hypotonia would improve considerably if muscle strength could be measured objectively and normal reference values were available. The authors developed a method to measure muscle strength in infants and tested 81 typically developing infants, 6-36 months of age, and 17 infants with Prader-Willi Syndrome (PWS) aged 24 months. The inter-rater reliability of the measurement method was good (ICC=.84) and the convergent validity was confirmed by high Pearson's correlations between muscle strength, age, height, and weight (r=.79-.85). A multiple linear regression model was developed to predict muscle strength based on age, height, and weight, explaining 73% of the variance in muscle strength. In infants with PWS, muscle strength was significantly decreased. Pearson's correlations showed that infants with PWS in which muscle strength was more severely affected also had a larger motor developmental delay (r=.75). Copyright © 2013 Elsevier Ltd. All rights reserved.
Tests for early acceptance of concrete.
DOT National Transportation Integrated Search
1985-01-01
A literature survey and limited study of laboratory concretes were conducted to evaluate various methods for predicting concrete strengths at 28 days based on procedures for accelerated strength development or measurement of strength of normally cure...
Gupta, Neeraj; Kumar, Dilip; Palla, Aparna
2017-04-01
Orthodontists are commonly faced with the decision of what to do with debonded or inaccurately positioned brackets. An economical option to this dilemma is to recycle the brackets. Many recycling methods have been proposed, but the optimal bond strength of these recycled brackets needs further evaluation. Objectives: To evaluate and compare the effect of three recycling methods: (i) Sandblasting (ii) Sandblasting / direct flaming (iii) Sandblasting /direct flaming /acid bath solution on shear bond strength (SBS) of stainless steel brackets. Eighty human premolars were bonded with premolar stainless steel brackets as per manufacturer's instructions. The teeth were divided into 4 groups (n=20): Recycling and initial debonding was not done in Control group (Group I). After initial bonding, the brackets in the rest of the three experimental groups were debonded and recycled by following methods: (i) Sandblasting (Group II) (ii) Sandblasting /direct flaming (Group III) (iii) Sandblasting /direct flaming /acid bath solution (Group IV). Further the recycled brackets were bonded. The specimens were then subjected to testing in a Universal machine. The evaluation of the variation of the shear bond strength (SBS) among test groups was done using one-way ANOVA test and inter-experimental group comparison was done by Newman-Keuls multiple post hoc procedure. Group I (8.6510±1.3943MPa) showed the highest bond strength followed by Group II (5.0185±0.9758MPa), Group IV (2.30±0.65MPa) and Group III (2.0455± 0.6196MPa). Statistically significant variations existed in the shear bond strength (SBS) in all groups analyzed except between Group III and Group IV. The following conclusions were drawn from the study: 1. Shear bond strength of new brackets is significantly higher than the recycled brackets. 2. Brackets sandblasted with 90µm aluminium oxide particle air-abrasion showed significantly higher shear bond strength compared to direct flaming/sandblasting and direct flaming/sandblasting/acid bath solution. 3. Sandblasting with 90µm aluminium oxide particle air-abrasion is the simplest, most efficient and hence, the preferred method of recycling debonded brackets. Key words: Orthodontic bracket, recycling, shear bond strength.
NASA Astrophysics Data System (ADS)
Hamada, Y.; Kitamura, M.; Yamada, Y.; Sanada, Y.; Moe, K.; Hirose, T.
2016-12-01
In-situ rock properties in/around seismogenic zone in an accretionary prism are key parameters to understand the development mechanisms of an accretionary prism, spatio-temporal variation of stress state, and so on. For the purpose of acquiring continuous-depth-profile of in-situ formation strength in an accretionary prism, here we propose the new method to evaluate the in-situ rock strength using drilling performance property. Drilling parameters are inevitably obtained by any drilling operation even in the non-coring intervals or at challenging environment where core recovery may be poor. The relationship between the rock properties and drilling parameters has been proposed by previous researches [e.g. Teale 1964]. We introduced the relationship theory of Teale [1964], and developed a converting method to estimate in-situ rock strength without depending on uncertain parameters such as weight on bit (WOB). Specifically, we first calculated equivalent specific toughness (EST) which represents gradient of the relationship between Torque energy and volume of penetration at arbitrary interval (in this study, five meters). Then the EST values were converted into strength using the drilling parameters-rock strengths correlation obtained by Karasawa et al. [2002]. This method was applied to eight drilling holes in the Site C0002 of IODP NanTroSEIZE in order to evaluate in-situ rock strength in shallow to deep accretionary prism. In the shallower part (0 - 300 mbsf), the calculated strength shows sharp increase up to 20 MPa. Then the strength has approximate constant value to 1500 mbsf without significant change even at unconformity around 1000 mbsf (boundary between forearc basin and accretionary prism). Below that depth, value of the strength gradually increases with depth up to 60 MPa at 3000 mbsf with variation between 10 and 80 MPa. Because the calculated strength is across approximately the same lithology, the increase trend can responds to the rock strength. This strength-depth curve correspond reasonably well with the strength data of core and cutting samples collected from hole C0002N and C0002P [Kitamura et al., 2016 AGU]. These results show the validity of the method evaluating in-situ strength from the drilling parameters.
ERIC Educational Resources Information Center
Miciak, Jeremy; Fletcher, Jack M.; Stuebing, Karla K.; Vaughn, Sharon; Tolar, Tammy D.
2014-01-01
Few empirical investigations have evaluated learning disabilities (LD) identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability and validity of two proposed PSW methods: the concordance/discordance method (C/DM) and cross battery assessment (XBA) method. Cognitive assessment…
ERIC Educational Resources Information Center
Londeree, Ben R.
1981-01-01
Postural deviations resulting from strength and flexibility imbalances include swayback, scoliosis, and rounded shoulders. Screening tests are one method for identifying strength problems. Tests for the evaluation of postural problems are described, and exercises are presented for the strengthening of muscles. (JN)
Philip, Jacob M; Ganapathy, Dhanraj M; Ariga, Padma
2012-07-01
This study was formulated to evaluate and estimate the influence of various denture base resin surface pre-treatments (chemical and mechanical and combinations) upon tensile bond strength between a poly vinyl acetate-based denture liner and a denture base resin. A universal testing machine was used for determining the bond strength of the liner to surface pre-treated acrylic resin blocks. The data was analyzed by one-way analysis of variance and the t-test (α =.05). This study infers that denture base surface pre-treatment can improve the adhesive tensile bond strength between the liner and denture base specimens. The results of this study infer that chemical, mechanical, and mechano-chemical pre-treatments will have different effects on the bond strength of the acrylic soft resilient liner to the denture base. Among the various methods of pre-treatment of denture base resins, it was inferred that the mechano-chemical pre-treatment method with air-borne particle abrasion followed by monomer application exhibited superior bond strength than other methods with the resilient liner. Hence, this method could be effectively used to improve bond strength between liner and denture base and thus could minimize delamination of liner from the denture base during function.
Relationship between agility and lower limb muscle strength, targeting university badminton players.
Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Yokota, Yuki; Kawagoe, Mirei; Nakayama, Yasuaki; Bito, Tsubasa; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Yoshimi, Soyoka; Aoyama, Tomoki
2018-02-01
[Purpose] Targeting university badminton players, this study investigated the relationship between agility, which is associated with performance in badminton, and lower limb muscle strength, and examined which muscles influence agility. [Subjects and Methods] A total of 23 male university badminton players were evaluated for side-shuffle test scores and lower limb strength. The relationships between agility, lower limb strength, and duration of experience playing badminton were evaluated using a correlation analysis. Moreover, the relationship between agility and lower limb strength was evaluated by partial correlation analysis, adjusting for the effects of experience of each badminton player. [Results] The agility score correlated with hip extension and ankle plantar flexion strength, with adjustment for badminton experience. [Conclusion] This study suggests that hip extension training and improvement in ankle plantar flexion strength may improve agility.
Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung
2017-10-01
To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.
2017-01-01
Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818
Kumar, Dilip; Palla, Aparna
2017-01-01
Background Orthodontists are commonly faced with the decision of what to do with debonded or inaccurately positioned brackets. An economical option to this dilemma is to recycle the brackets. Many recycling methods have been proposed, but the optimal bond strength of these recycled brackets needs further evaluation. Objectives: To evaluate and compare the effect of three recycling methods: (i) Sandblasting (ii) Sandblasting / direct flaming (iii) Sandblasting /direct flaming /acid bath solution on shear bond strength (SBS) of stainless steel brackets. Material and Methods Eighty human premolars were bonded with premolar stainless steel brackets as per manufacturer’s instructions. The teeth were divided into 4 groups (n=20): Recycling and initial debonding was not done in Control group (Group I). After initial bonding, the brackets in the rest of the three experimental groups were debonded and recycled by following methods: (i) Sandblasting (Group II) (ii) Sandblasting /direct flaming (Group III) (iii) Sandblasting /direct flaming /acid bath solution (Group IV). Further the recycled brackets were bonded. The specimens were then subjected to testing in a Universal machine. The evaluation of the variation of the shear bond strength (SBS) among test groups was done using one-way ANOVA test and inter-experimental group comparison was done by Newman-Keuls multiple post hoc procedure. Results Group I (8.6510±1.3943MPa) showed the highest bond strength followed by Group II (5.0185±0.9758MPa), Group IV (2.30±0.65MPa) and Group III (2.0455± 0.6196MPa). Statistically significant variations existed in the shear bond strength (SBS) in all groups analyzed except between Group III and Group IV. Conclusions The following conclusions were drawn from the study: 1. Shear bond strength of new brackets is significantly higher than the recycled brackets. 2. Brackets sandblasted with 90µm aluminium oxide particle air-abrasion showed significantly higher shear bond strength compared to direct flaming/sandblasting and direct flaming/sandblasting/acid bath solution. 3. Sandblasting with 90µm aluminium oxide particle air-abrasion is the simplest, most efficient and hence, the preferred method of recycling debonded brackets. Key words:Orthodontic bracket, recycling, shear bond strength. PMID:28469821
Determine the Compressive Strength of Calcium Silicate Bricks by Combined Nondestructive Method
2014-01-01
The paper deals with the application of combined nondestructive method for assessment of compressive strength of calcium silicate bricks. In this case, it is a combination of the rebound hammer method and ultrasonic pulse method. Calibration relationships for determining compressive strength of calcium silicate bricks obtained from nondestructive parameter testing for the combined method as well as for the L-type Schmidt rebound hammer and ultrasonic pulse method are quoted here. Calibration relationships are known for their close correlation and are applicable in practice. The highest correlation between parameters from nondestructive measurement and predicted compressive strength is obtained using the SonReb combined nondestructive method. Combined nondestructive SonReb method was proved applicable for determination of compressive strength of calcium silicate bricks at checking tests in a production plant and for evaluation of bricks built in existing masonry structures. PMID:25276864
Method of testing gear wheels in impact bending
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tikhonov, A.K.; Palagin, Y.M.
1995-05-01
Chemicothermal treatment processes are widely used in engineering to improve the working lives of important components, of which the most common is nitrocementation. That process has been applied at the Volga Automobile Plant mainly to sprockets in gear transmissions, which need high hardness and wear resistance in the surfaces with relatively ductile cores. Although various forms of chemicothermal treatment are widely used, there has been no universal method of evaluating the strengths of gear wheels. Standard methods of estimating strength ({sigma}{sub u}, {sigma}{sub t}, {sigma}{sub b}, and hardness) have a major shortcoming: They can determine only the characteristics of themore » cores for case-hardened materials. Here we consider a method of impact bending test, which enables one to evaluate the actual strength of gear teeth.« less
NASA Technical Reports Server (NTRS)
Madaras, E. I.; Poe, C. C.; Heyman, J. S.
1987-01-01
A model for predicting the fracture strength of homogeneous materials is proposed. Impacted FWC samples were evaluated using ultrasonic testing and an X-ray dye penetration method. The ability of the model to measure fracture strength was also examined. The relation between attenuation and velocity measurements is studied. It is observed that the X-ray method is not useful for predicting fracture strength because the dye could not penetrate the matrix. It is noted that fracture strength predictions derived from the fracture mechanical model and the ultrasonic measurements correlate well with actual measured fracture strengths.
Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations.
Teng, Jili; Wang, Hang; Liao, Yunmao; Liang, Xing
2012-06-01
The high strength and fracture toughness of zirconia have supported its extensive application in esthetic dentistry. However, the fracturing of veneering porcelains remains one of the primary causes of failure. The purpose of this study was to evaluate, with shear bond strength testing, the effect of a simple and novel surface conditioning method on the core-veneer bond strength of a zirconia ceramic system. The shear bond strength of a zirconia core ceramic to the corresponding veneering porcelain was tested by the Schmitz-Schulmeyer method. Thirty zirconia core specimens (10 × 5 × 5 mm) were layered with a veneering porcelain (5 × 3 × 3 mm). Three different surface conditioning methods were evaluated: polishing with up to 1200 grit silicon carbide paper under water cooling, airborne-particle abrasion with 110 μm alumina particles, and modification with zirconia powder coating before sintering. A metal ceramic system was used as a control group. All specimens were subjected to shear force in a universal testing machine at a crosshead speed of 0.5 mm/min. The shear bond strength values were analyzed with 1-way ANOVA and Tukey's post hoc pairwise comparisons (α=.05). The fractured specimens were examined with a scanning electron microscope to observe the failure mode. The mean (SD) shear bond strength values in MPa were 47.02 (6.4) for modified zirconia, 36.66 (8.6) for polished zirconia, 39.14 (6.5) for airborne-particle-abraded zirconia, and 46.12 (7.1) for the control group. The mean bond strength of the control (P=.028) and modified zirconia groups (P=.014) was significantly higher than that of the polished zirconia group. The airborne-particle-abraded group was not significantly different from any other group. Scanning electron microscopy evaluation showed that cohesive fracture in the veneering porcelain was the predominant failure mode of modified zirconia, while the other groups principally fractured at the interface. Modifying the zirconia surface with powder coating could significantly increase the shear bond strength of zirconia to veneering porcelain. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Montero, Manuela M Haro; Vicente, Ascensión; Alfonso-Hernández, Noelia; Jiménez-López, Manuel; Bravo-González, Luis-Alberto
2015-05-01
To evaluate in vitro the shear bond strength of brackets recycled by sandblasting with aluminum oxide particles of different sizes or reconditioned industrially after successive rebonding. Eighty brackets were bonded and debonded sequentially three times. After the first debonding, brackets were divided into four groups: (group 1) sandblasting with aluminum oxide particles of 25 μ, (group 2) 50 μ, and (group 3) 110 μ, and (group 4) industrial recycling. Bond strength and adhesive material remaining on debonded bracket bases were evaluated for each successive debond. No significant differences were detected between the four groups following the first recycle (P > .05). After the second recycle, bond strength was significantly greater for the industrially recycled group than the other groups (P < .016). When shear bond strength was compared within each recycling method, the bond strength of sandblasted brackets decreased with the increase of particle size and with each recycle; for the industrially recycled group, no significant differences were detected between the three sequences (P > .016). In the evaluation of bond material remnant, the industrially recycled group left significantly less bond material after successive recycling than the other groups did (P < .016). Within each recycling method, the adhesive remnant decreased significantly after successive debond (P < .016). Industrial recycling obtained better results than sandblasting after three successive debondings. The brackets' shear bond strength decreased as the size of the aluminum oxide particle used for sandblasting increased and as recycling was repeated.
Saito, Ken; Eishiro, Yoshinori; Nakao, Yoshihide; Sato, Hirofumi; Sakaki, Shigeyoshi
2012-03-05
The theoretical evaluation of the oscillator strength of a symmetry-forbidden d-d transition is not easy even nowadays. A new approximate method is proposed here and applied to octahedral complexes [Co(NH(3))(6)](3+) and [Rh(NH(3))(6)](3+) as an example. Our method incorporates the effects of geometry distortion induced by molecular vibration and the thermal distribution of such distorted geometries but does not need the Herzberg-Teller approximation. The calculated oscillator strengths of [Co(NH(3))(6)](3+) agree well with the experimental values in both (1)A(1g) → (1)T(1g) and (1)A(1g) → (1)T(2g) transitions. In the Rh analogue, though the calculated oscillator strengths are somewhat smaller than the experimental values, computational results reproduce well the experimental trends that the oscillator strengths of [Rh(NH(3))(6)](3+) are much larger than those of the Co analogue and the oscillator strength of the (1)A(1g) → (1)T(1g) transition is larger than that of the (1)A(1g) → (1)T(2g) transition. It is clearly shown that the oscillator strength is not negligibly small even at 0 K because the distorted geometry (or the uncertainty in geometry) by zero-point vibration contributes to the oscillator strength at 0 K. These results are discussed in terms of frequency of molecular vibration, extent of distortion induced by molecular vibration, and charge-transfer character involved in the d-d transition. The computational results clearly show that our method is useful in evaluating and discussing the oscillator strength of symmetry-forbidden d-d absorption of transition metal complex.
Intentional Forgetting Is Easier after Two "Shots" than One
ERIC Educational Resources Information Center
Sahakyan, Lili; Delaney, Peter F.; Waldum, Emily R.
2008-01-01
Three experiments evaluated whether the magnitude of the list-method directed forgetting effect is strength dependent. Throughout these studies, items were strengthened via operations thought to increase context strength (spaced presentations) or manipulations thought to increment the item strength without affecting the context strength…
Muscle strength and fatigue in newly diagnosed patients with myasthenia gravis.
Vinge, Lotte; Andersen, Henning
2016-10-01
Dynamometry is increasingly used as an objective measurement of muscle strength in neurological diseases. No study has applied dynamometry in untreated newly diagnosed patients with myasthenia gravis (MG). Isometric muscle strength at the shoulder, knee, and ankle was determined in 21 MG patients before and after initial anti-myasthenic treatment. Isometric strength was compared with MG evaluation scales. Muscle strength was reduced for knee extensors and shoulder abductors but normal for ankle extensors. Isometric muscle strength did not correlate significantly with manual muscle testing (MG Composite). Dynamometry revealed improved muscle strength of up to 50% (median 17%; range -1.8-49.8) despite no change in the MG Composite score. Dynamometry appears to be a more sensitive method of identifying changes in limb strength than MG evaluation scales. This supports the use of dynamometry in MG patients, especially for evaluation of the effect of anti-myasthenic treatment. Muscle Nerve 54: 709-714, 2016. © 2016 Wiley Periodicals, Inc.
Importance and challenges of measuring intrinsic foot muscle strength
2012-01-01
Background Intrinsic foot muscle weakness has been implicated in a range of foot deformities and disorders. However, to establish a relationship between intrinsic muscle weakness and foot pathology, an objective measure of intrinsic muscle strength is needed. The aim of this review was to provide an overview of the anatomy and role of intrinsic foot muscles, implications of intrinsic weakness and evaluate the different methods used to measure intrinsic foot muscle strength. Method Literature was sourced from database searches of MEDLINE, PubMed, SCOPUS, Cochrane Library, PEDro and CINAHL up to June 2012. Results There is no widely accepted method of measuring intrinsic foot muscle strength. Methods to estimate toe flexor muscle strength include the paper grip test, plantar pressure, toe dynamometry, and the intrinsic positive test. Hand-held dynamometry has excellent interrater and intrarater reliability and limits toe curling, which is an action hypothesised to activate extrinsic toe flexor muscles. However, it is unclear whether any method can actually isolate intrinsic muscle strength. Also most methods measure only toe flexor strength and other actions such as toe extension and abduction have not been adequately assessed. Indirect methods to investigate intrinsic muscle structure and performance include CT, ultrasonography, MRI, EMG, and muscle biopsy. Indirect methods often discriminate between intrinsic and extrinsic muscles, but lack the ability to measure muscle force. Conclusions There are many challenges to accurately measure intrinsic muscle strength in isolation. Most studies have measured toe flexor strength as a surrogate measure of intrinsic muscle strength. Hand-held dynamometry appears to be a promising method of estimating intrinsic muscle strength. However, the contribution of extrinsic muscles cannot be excluded from toe flexor strength measurement. Future research should clarify the relative contribution of intrinsic and extrinsic muscles during intrinsic foot muscle strength testing. PMID:23181771
Subgrade evaluation based on theoretical concepts.
DOT National Transportation Integrated Search
1971-01-01
Evaluations of pavement soil subgrades for the purpose of design are mostly based on empirical methods such as the CBR, California soil resistance method, etc. The need for the application of theory and the evaluation of subgrade strength in terms of...
Study on axial strength of a channel-shaped pultruded GFRP member
NASA Astrophysics Data System (ADS)
Matsumoto, Yukihiro; Satake, Chito; Nisida, Kenji
2017-10-01
Fiber reinforced polymers (FRP) are widely used in vehicle and aerospace applications because of their lightweight and high-strength characteristics. Additionally, FRPs are increasingly applied to building structures. However, the elastic modulus of glass fiber reinforced polymers (GFRPs) is lower than that of steel. Hence, the evaluating the buckling strength of GFRP members for design purpose is necessary. The buckling strength is determined by Euler buckling mode as well as local buckling. In this study investigated the compressive strength of GFRP members subjected to axial compression through experiments and theoretical calculations. The adopted GFRP member was a channel-shaped GFRP, which was molded via pultrusion, at various lengths. Although, the mechanical properties as longitudinal elastic modulus and fiber volume fraction and strength of GFRP members subjected, to axial can be easily evaluated, evaluating transverse elastic modulus and shear modulus in typical material tests is difficult in standard section. Therefore the composite law was used in this study. As a result, we confirmed that the axial strength of a GFRP member could be calculated by a theoretical evaluation method utilizing longitudinal elastic modulus and fiber volume fraction.
Evaluation of a sugar based edible adhesive utilizing a tensile strength tester
USDA-ARS?s Scientific Manuscript database
A new method to evaluate adhesives has been developed and utilized to formulate a recently patented adhesive based on sugar and citric acid. Factors affecting adhesive performance were uncovered, such as reduced strength due to improper heating time, and an optimal curing temperature of 60oC was ac...
Slab replacement maturity guidelines.
DOT National Transportation Integrated Search
2014-04-01
This study investigated the use of maturity method to determine early age strength of concrete in slab : replacement application. Specific objectives were (1) to evaluate effects of various factors on the compressive : maturity-strength relationship ...
I-SonReb: an improved NDT method to evaluate the in situ strength of carbonated concrete
NASA Astrophysics Data System (ADS)
Breccolotti, Marco; Bonfigli, Massimo F.
2015-10-01
Concrete strength evaluated in situ by means of the conventional SonReb method can be highly overestimated in presence of carbonation. This latter, in fact, is responsible for the physical and chemical alteration of the outer layer of concrete. As most of the existing concrete structures are subjected to carbonation, it is of high importance to overcome this problem. In this paper, an Improved SonReb method (I-SonReb) for carbonated concretes is proposed. It relies on the definition of a correction coefficient of the measured Rebound index as a function of the carbonated concrete cover thickness, an additional parameter to be measured during in situ testing campaigns. The usefulness of the method has been validated showing the improvement in the accuracy of concrete strength estimation from two sets of NDT experimental data collected from investigations on real structures.
Estimation of muscle strength during motion recognition using multichannel surface EMG signals.
Nagata, Kentaro; Nakano, Takemi; Magatani, Kazushige; Yamada, Masafumi
2008-01-01
The use of kinesiological electromyography is established as an evaluation tool for various kinds of applied research, and surface electromyogram (SEMG) has been widely used as a control source for human interfaces such as in a myoelectric prosthetic hand (we call them 'SEMG interfaces'). It is desirable to be able to control the SEMG interfaces with the same feeling as body movement. The existing SEMG interface mainly focuses on how to achieve accurate recognition of the intended movement. However, detecting muscular strength and reduced number of electrodes are also an important factor in controlling them. Therefore, our objective in this study is the development of and the estimation method for muscular strength that maintains the accuracy of hand motion recognition to reflect the result of measured power in a controlled object. Although the muscular strength can be evaluated by various methods, in this study a grasp force index was applied to evaluate the muscular strength. In order to achieve our objective, we directed our attention to measuring all valuable information for SEMG. This work proposes an application method of two simple linear models, and the selection method of an optimal electrode configuration to use them effectively. Our system required four SEMG measurement electrodes in which locations differed for every subject depending on the individual's characteristics, and those were selected from a 96ch multi electrode using the Monte Carlo method. From the experimental results, the performance in six normal subjects indicated that the recognition rate of four motions were perfect and the grasp force estimated result fit well with the actual measurement result.
Ultrasound transmission measurements for tensile strength evaluation of tablets.
Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko
2011-05-16
Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.
Evaluation of strength-controlling defects in paper by stress concentration analyses
John M. Considine; David W. Vahey; James W. Evans; Kevin T. Turner; Robert E. Rowlands
2011-01-01
Cellulosic webs, such as paper materials, are composed of an interwoven, bonded network of cellulose fibers. Strength-controlling parameters in these webs are influenced by constituent fibers and method of processing and manufacture. Instead of estimating the effect on tensile strength of each processing/manufacturing variable, this study modifies and compares the...
An investigation of the compressive strength of PRD-49-3/Epoxy composites
NASA Technical Reports Server (NTRS)
Kulkarni, S. V.; Rice, J. S.; Rosen, B. W.
1973-01-01
The development of unidirectional fiber composite materials is discussed. The mechanical and physical properties of the materials are described. Emphasis is placed in analyzing the compressive behavior of composite materials and developing methods for increasing compressive strength. The test program for evaluating the various procedures for improving compressive strength are reported.
Standard Methods for Bolt-Bearing Testing of Textile Composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Masters, J. E.
1995-01-01
The response of three 2-D braided materials to bolt bearing loading was evaluated using data generated by Boeing Defense and Space Group in Philadelphia, PA. Three test methods, stabilized single shear, unstabilized single shear, and double shear, were compared. In general, these textile composites were found to be sensitive to bolt bearing test methods. The stabilized single shear method yielded higher strengths than the unstabilized single shear method in all cases. The double shear test method always produced the highest strengths but these results may be somewhat misleading. It is therefore recommended that standard material comparisons be made using the stabilized single shear test method. The effects of two geometric parameters, W/D and e/D, were also studied. An evaluation of the effect of the specimen width (W) to hole diameter (D) ratio concluded that bolt bearing responses were consistent with open hole tension results. A W/D ratio of 6 or greater should be maintained. The proximity of the hole to the specimen edge significantly affected strength. In all cases, strength was improved by increasing the ratio of the distance from the hole center to the specimen edge (e) to the hole diameter (D) above 2. An e/D ratio of 3 or greater is recommended.
Effect of different aging methods on the mechanical behavior of multi-layered ceramic structures.
Borba, Márcia; de Araújo, Maico D; Fukushima, Karen A; Yoshimura, Humberto N; Griggs, Jason A; Della Bona, Álvaro; Cesar, Paulo F
2016-12-01
To evaluate the effect of two aging methods (mechanical cycling and autoclave) on the mechanical behavior of veneer and framework ceramic specimens with different configurations (monolithic, two and three-layers). Three ceramics used as framework for fixed dental prostheses (YZ-Vita In-Ceram YZ; IZ-Vita In-Ceram Zirconia; AL-Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs: monolithic, two layers (porcelain-framework) and three layers (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. Three different experimental conditions were evaluated (n=10): control; mechanical cycling (2Hz, 37°C artificial saliva); and autoclave aging (134°C, 2 bars, 5h). Bi-layered specimens were tested in both conditions: with porcelain or framework ceramic under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy. Results were statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls tests. Only for AL group, mechanical cycling and autoclave aging significantly decreased the flexural strength values in comparison to the control (p<0.01). YZ, AL, VM7 and VM9 monolithic groups showed no strength degradation. For multi-layered specimens, when the porcelain layer was tested in tension (bi and tri-layers), the aging methods evaluated also had no effect on strength (p≥0.05). Total and partial failure modes were identified. Mechanical cycling and autoclave aging protocols had no effect on the flexural strength values and failure behavior of YZ and IZ ceramic structures. Yet, AL monolithic structures showed a significant decrease in flexural strength with any of the aging methods. Copyright © 2016. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Hinoki, Tatsuya
Evaluation techniques and mechanical properties of silicon carbide composites (SiC⁄SiC composites) reinforced with highly crystalline fibers are reviewed for fusion applications. The SiC⁄SiC composites used were fabricated by means of the CVI method. The evaluation includes in-plane tensile strength by in-plane tensile test, transthickness tensile strength by transthickness tensile test and diametral compression test and shear strength by compression test using double-notched specimen. All tests were successfully conducted using small specimens for neutron irradiation experiment. As application technique, the novel tungsten(W) coating technique on SiC is reviewed. The W powder melted by high power lamp in a few seconds and formed coating on SiC. No thick reaction layers of WC and W5Si3, which are formed by the other coating methods, were formed by this method.
Li, Jieyin; Ye, Xiuhua; Li, Bohua; Liao, Juankun; Zhuang, Peilin; Ye, Jiantao
2015-08-01
There is a dearth of dental scientific literature on the effect of different oxidation heat treatments (OHTs) (as surface pretreatments) on the bonding performance of cast and milled cobalt-chromium (CoCr) alloys. The objective of this study was to evaluate the effect of different OHTs on the bond strength between a ceramic and cast and milled CoCr alloys. Cobalt-chromium metallic specimens were prepared using either a cast or a milled method. Specimens were subjected to four different OHT methods: without OHT; OHT under normal atmospheric pressure; OHT under vacuum; and OHT under vacuum followed by sandblasting. The metal-ceramic bond strength was evaluated using a three-point bending test according to ISO9693. Scanning electron microscopy and energy-dispersive spectroscopy were used to study the specimens' microstructure and elemental composition. The bond strength was not affected by the CoCr manufacturing method. Oxidation heat treatment performed under normal atmospheric pressure resulted in the highest bond strength. The concentration of oxygen on the alloy surfaces varied with the different pretreatment methods in the following order: OHT under normal atmospheric pressure > OHT under vacuum > without OHT ≈ OHT under vacuum followed by sandblasting. © 2015 Eur J Oral Sci.
ERIC Educational Resources Information Center
Miciak, Jeremy; Taylor, W. Pat; Denton, Carolyn A.; Fletcher, Jack M.
2015-01-01
Few empirical investigations have evaluated learning disabilities (LD) identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability of LD classification decisions of the concordance/discordance method (C/DM) across different psychoeducational assessment batteries. C/DM criteria were…
A comparison of analysis methods to estimate contingency strength.
Lloyd, Blair P; Staubitz, Johanna L; Tapp, Jon T
2018-05-09
To date, several data analysis methods have been used to estimate contingency strength, yet few studies have compared these methods directly. To compare the relative precision and sensitivity of four analysis methods (i.e., exhaustive event-based, nonexhaustive event-based, concurrent interval, concurrent+lag interval), we applied all methods to a simulated data set in which several response-dependent and response-independent schedules of reinforcement were programmed. We evaluated the degree to which contingency strength estimates produced from each method (a) corresponded with expected values for response-dependent schedules and (b) showed sensitivity to parametric manipulations of response-independent reinforcement. Results indicated both event-based methods produced contingency strength estimates that aligned with expected values for response-dependent schedules, but differed in sensitivity to response-independent reinforcement. The precision of interval-based methods varied by analysis method (concurrent vs. concurrent+lag) and schedule type (continuous vs. partial), and showed similar sensitivities to response-independent reinforcement. Recommendations and considerations for measuring contingencies are identified. © 2018 Society for the Experimental Analysis of Behavior.
ERIC Educational Resources Information Center
Czarniecka, Renata; Milde, Katarzyna; Tomaszewski, Pawel
2012-01-01
Study aim: To evaluate changes in strength abilities of adolescent girls that underwent a 3-year physical education curriculum. Material and methods: The research participants comprised 141 girls aged 13.3 plus or minus 0.35 years who participated in a 3-year physical education curriculum (PEC). Evaluation was based on the following EUROFIT…
The internal bond and shear strength of hardwood veneered particleboard composites
P. Chow; J.J. Janowiak; E.W. Price
1986-01-01
The effects of several accelerated aging tests and weather exposures on hardwood reconstituted structural composite panels were evaluated. The results indicated that the internal bond and shear by tension loading strength reductions of the panels were affected by the exposure test method. The ranking of the effects of various exposure tests on strength values in an...
Novel Strength Test Battery to Permit Evidence-Based Paralympic Classification
Beckman, Emma M.; Newcombe, Peter; Vanlandewijck, Yves; Connick, Mark J.; Tweedy, Sean M.
2014-01-01
Abstract Ordinal-scale strength assessment methods currently used in Paralympic athletics classification prevent the development of evidence-based classification systems. This study evaluated a battery of 7, ratio-scale, isometric tests with the aim of facilitating the development of evidence-based methods of classification. This study aimed to report sex-specific normal performance ranges, evaluate test–retest reliability, and evaluate the relationship between the measures and body mass. Body mass and strength measures were obtained from 118 participants—63 males and 55 females—ages 23.2 years ± 3.7 (mean ± SD). Seventeen participants completed the battery twice to evaluate test–retest reliability. The body mass–strength relationship was evaluated using Pearson correlations and allometric exponents. Conventional patterns of force production were observed. Reliability was acceptable (mean intraclass correlation = 0.85). Eight measures had moderate significant correlations with body size (r = 0.30–61). Allometric exponents were higher in males than in females (mean 0.99 vs 0.30). Results indicate that this comprehensive and parsimonious battery is an important methodological advance because it has psychometric properties critical for the development of evidence-based classification. Measures were interrelated with body size, indicating further research is required to determine whether raw measures require normalization in order to be validly applied in classification. PMID:25068950
Kanashiro, Lylian K; Robles-Ruíz, Julissa J; Ciamponi, Ana L; Medeiros, Igor S; Tortamano, André; Paiva, João B
2014-09-01
To determine the influence on shear bond strength and bond failure location of four cleaning methods for orthodontic bracket custom bases. In vitro laboratory study. Eighty bovine teeth were divided at random into four groups. The bracket custom bases were cleaned with different methods: group 1 with methyl methacrylate monomer, group 2 with acetone, group 3 with 50 μm aluminium oxide particles and group 4 with detergent. The brackets were indirectly bonded onto the teeth with the Sondhi Rapid-Set self-curing adhesive. The maximum required shear bond strength to debond the brackets was recorded. The bond failure location was evaluated using the Adhesive Remnant Index (ARI). One-way analysis of variance (ANOVA) analysis (P<0·05) was used to detect significant differences in the bond strength. Kaplan-Meier survival plots and log-rank test were done to compare the survival distribution between the groups. The Kruskal-Wallis test (P<0·05) was used to evaluate the differences in the ARI scores. The mean bond strengths in groups 1, 2, 3 and 4 were 23·7±5·0, 25·3±5·1, 25·6±3·7 and 25·7±4·2 MPa, respectively. There were no significant statistically differences in either the bond strength or the ARI score between the groups. The four custom base-cleaning methods presented the same efficiencies on indirect bond of the brackets; thus, practitioners can choose the method that works best for them. © 2014 British Orthodontic Society.
Using a fuzzy comprehensive evaluation method to determine product usability: A test case
Zhou, Ronggang; Chan, Alan H. S.
2016-01-01
BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942
Using a fuzzy comprehensive evaluation method to determine product usability: A test case.
Zhou, Ronggang; Chan, Alan H S
2017-01-01
In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.
Digholkar, Shruti; Madhav, V. N. V.; Palaskar, Jayant
2016-01-01
Purpose: The purpose of this study was to evaluate and compare the flexural strength and microhardness of provisional restorative materials fabricated utilizing rapid prototyping (RP), Computer Assisted Designing and Computer Assisted Milling (CAD-CAM) and conventional method. Materials and Methods: Twenty specimens of dimensions 25 mm × 2 mm × 2 mm (ADA-ANSI specification #27) were fabricated each using: (1) Three dimensional (3D) printed light-cured micro-hybrid filled composite by RP resin group, (2) a milled polymethyl methacrylate (CH) using CAD-CAM (CC resin group), and (3) a conventionally fabricated heat activated polymerized CH resin group. Flexural strength and microhardness were measured and values obtained were evaluated. Results: The measured mean flexural strength values (MegaPascals) were 79.54 (RP resin group), 104.20 (CC resin group), and 95.58 (CH resin group). The measured mean microhardness values (Knoop hardness number) were 32.77 (RP resin group), 25.33 (CC resin group), and 27.36 (CH resin group). The analysis of variance (ANOVA) test shows that there is statistically significant difference in the flexural strength values of the three groups (P < 0.05). According to the pairwise comparison of Tukey's honest significant difference (HSD) test, flexural strength values of CC resin group and CH resin group were higher and statistically significant than those of the RP resin group (P < 0.05). However, there was no significant difference between flexural strength values of CC resin and CH resin group (P = 0.64). The difference in microhardness values of the three groups was statistically significant according to ANOVA as well as the intergroup comparison done using the Tukey's HSD (post hoc) test (P < 0.05). Conclusions: CC-based CH had the highest flexural strength whereas RP-based 3D printed and light cured micro-hybrid filled composite had the highest microhardness. PMID:27746595
DOE Office of Scientific and Technical Information (OSTI.GOV)
Won, Jong-Pil, E-mail: jpwon@konkuk.ac.kr; Hwang, Un-Jong; Lee, Su-Jin
This study evaluated the performance of shotcrete using high strength C{sub 12}A{sub 7} mineral-based accelerator that has been developed to improve the durability and long-term strength. Rebound, compressive strength and flexural strength were tested in the field. Test result showed that existing C{sub 12}A{sub 7} mineral-based accelerator exhibits better early strength than the high-strength C{sub 12}A{sub 7} mineral-based accelerator until the early age, but high-strength C{sub 12}A{sub 7} mineral-based accelerator shows about 29% higher at the long-term age of 28 days. Microstructural analysis such as scanning electron microscope (SEM), X-ray diffraction (XRD) and nitrogen adsorption method was evaluated to analyzemore » long-term strength development mechanism of high strength C{sub 12}A{sub 7} mineral-based accelerator. As analysis result, it had more dense structure due to the reaction product by adding material that used to enhanced strength. It had better resistance performance in chloride ion penetration, freezing–thawing and carbonation than shotcrete that used existing C{sub 12}A{sub 7} mineral-based accelerator.« less
Muscle strength and knee range of motion after femoral lengthening.
Bhave, Anil; Shabtai, Lior; Woelber, Erik; Apelyan, Arman; Paley, Dror; Herzenberg, John E
2017-04-01
Background and purpose - Femoral lengthening may result in decrease in knee range of motion (ROM) and quadriceps and hamstring muscle weakness. We evaluated preoperative and postoperative knee ROM, hamstring muscle strength, and quadriceps muscle strength in a diverse group of patients undergoing femoral lengthening. We hypothesized that lengthening would not result in a significant change in knee ROM or muscle strength. Patients and methods - This prospective study of 48 patients (mean age 27 (9-60) years) compared ROM and muscle strength before and after femoral lengthening. Patient age, amount of lengthening, percent lengthening, level of osteotomy, fixation time, and method of lengthening were also evaluated regarding knee ROM and strength. The average length of follow-up was 2.9 (2.0-4.7) years. Results - Mean amount of lengthening was 5.2 (2.4-11.0) cm. The difference between preoperative and final knee flexion ROM was 2° for the overall group. Congenital shortening cases lost an average of 5% or 6° of terminal knee flexion, developmental cases lost an average of 3% or 4°, and posttraumatic cases regained all motion. The difference in quadriceps strength at 45° preoperatively and after lengthening was not statistically or clinically significant (2.7 Nm; p = 0.06). Age, amount of lengthening, percent lengthening, osteotomy level, fixation time, and lengthening method had no statistically significant influence on knee ROM or quadriceps strength at final follow-up. Interpretation - Most variables had no effect on ROM or strength, and higher age did not appear to be a limiting factor for femoral lengthening. Patients with congenital causes were most affected in terms of knee flexion.
B.Z. Yang; R.D. Seale; R. Shmulsky; J. Dahlen; X. Wang
2017-01-01
The identification of strength-reducing characteristics that impact modulus of rupture (MOR) is a key differentiation between lumber grades. Because global design values for MOR are at the fifth percentile level and in-grade lumber can be highly variable, it is important that nondestructive evaluation technology be used to better discern the potential wood strength. In...
Santos, Kelli Maria Souza; de Cerqueira Neto, Manoel Luiz; Carvalho, Vitor Oliveira; de Santana Filho, Valter Joviniano; da Silva Junior, Walderi Monteiro; Araújo Filho, Amaro Afrânio; Cerqueira, Telma Cristina Fontes; Cacau, Lucas de Assis Pereira
2014-01-01
Introduction Peripheral muscle strength has been little explored in the literature in the context of cardiac rehabilitation. Objective To evaluate the peripheral muscle strength of patients undergoing elective cardiac surgery. Methods This was a longitudinal observational study. The peripheral muscle strength was measured using isometric dynamometry lower limb (knee extensors and flexors) at three different times: preoperatively (M1), the day of discharge (M2) and hospital discharge (M3). Participants received physiotherapy pre and postoperatively during the days of hospitalization during the morning and afternoon. Results Twenty-two patients were evaluated. The values of peripheral muscle strength of knee extensors preoperative found were about 50% lower than those predicted for the healthy population. When comparing muscle strength prior (M1), with the remaining evaluation, found himself in a fall of 29% for the movement of knee extension and 25% for knee flexion in M2 and a decrease of 10% movement for knee extension and 13% for knee flexion in M3 when comparing with M1. Conclusion The values of peripheral muscle strength prior of the study patients were lower than predicted for the healthy population of the same age. After the surgical event this reduction is even more remarkable, being reestablished until the time of discharge, to values close to baseline. PMID:25372909
Yasuda, Tomohiro; Fukumura, Kazuya; Nakajima, Toshiaki
2017-04-01
[Purpose] To examine if the SPPB is higher with healthy subjects than outpatients, which was higher than inpatients and if the SPPB can be validated assessment tool for strength tests and lower extremity morphological evaluation in cardiovascular disease patients. [Subjects and Methods] Twenty-four middle aged and older adults with cardiovascular disease were recruited from inpatient and outpatient facilities and assigned to separate experimental groups. Twelve age-matched healthy volunteers were assigned to a control group. SPPB test was used to assess balance and functional motilities. The test outcomes were compared with level of care (inpatient vs. outpatient), physical characteristics, strength and lower extremity morphology. [Results] Total SPPB scores, strength tests (knee extensor muscle strength), and lower extremity morphological evaluation (muscle thickness of anterior and posterior mid-thigh and posterior lower-leg) were greater in healthy subjects and outpatients groups compared with inpatients. To predict total Short Physical Performance Battery scores, the predicted knee extension and anterior mid-thigh muscle thickness were calculated. [Conclusion] The SPPB is an effective tool as the strength tests and lower extremity morphological evaluation for middle-aged and older adult cardiovascular disease patients. Notably, high knee extensor muscle strength and quadriceps femoris muscle thickness are positively associated with high SPPB scores.
Wang, Yue; Gregory, Cherry; Minor, Mark A
2018-06-01
Molded silicone rubbers are common in manufacturing of soft robotic parts, but they are often prone to tears, punctures, and tensile failures when strained. In this article, we present a fabric compositing method for improving the mechanical properties of soft robotic parts by creating a fabric/rubber composite that increases the strength and durability of the molded rubber. Comprehensive ASTM material tests evaluating the strength, tear resistance, and puncture resistance are conducted on multiple composites embedded with different fabrics, including polyester, nylon, silk, cotton, rayon, and several blended fabrics. Results show that strong fabrics increase the strength and durability of the composite, valuable in pneumatic soft robotic applications, while elastic fabrics maintain elasticity and enhance tear strength, suitable for robotic skins or soft strain sensors. Two case studies then validate the proposed benefits of the fabric compositing for soft robotic pressure vessel applications and soft strain sensor applications. Evaluations of the fabric/rubber composite samples and devices indicate that such methods are effective for improving mechanical properties of soft robotic parts, resulting in parts that can have customized stiffness, strength, and vastly improved durability.
Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.
Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph
2018-06-01
There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.
NASA Technical Reports Server (NTRS)
Pohlchuck, Bobby; Zeller, Mary V.
1992-01-01
The adhesive bond between ceramic cement and a titanium matrix composite substrate to be used in the National Aerospace Plane program is evaluated. Two commercially available adhesion testers, the Sebastian Adherence Tester and the CSEM REVETEST Scratch Tester, are evaluated to determine their suitability for quantitatively measuring adhesion strength. Various thicknesses of cements are applied to several substrates, and bond strengths are determined with both testers. The Sabastian Adherence Tester has provided limited data due to an interference from the sample mounting procedure, and has been shown to be incapable of distinguishing adhesion strength from tensile and shear properties of the cement itself. The data from the scratch tester has been found to be difficult to interpret due to the porosity and hardness of the cement. Recommendations are proposed for a more reliable adhesion test method.
A simulation-based evaluation of methods for inferring linear barriers to gene flow
Christopher Blair; Dana E. Weigel; Matthew Balazik; Annika T. H. Keeley; Faith M. Walker; Erin Landguth; Sam Cushman; Melanie Murphy; Lisette Waits; Niko Balkenhol
2012-01-01
Different analytical techniques used on the same data set may lead to different conclusions about the existence and strength of genetic structure. Therefore, reliable interpretation of the results from different methods depends on the efficacy and reliability of different statistical methods. In this paper, we evaluated the performance of multiple analytical methods to...
NASA Astrophysics Data System (ADS)
Ducousso, M.; Bardy, S.; Rouchausse, Y.; Bergara, T.; Jenson, F.; Berthe, L.; Videau, L.; Cuvillier, N.
2018-03-01
Intense acoustic shock waves were applied to evaluate the mechanical strength of structural epoxy bonds between a TA6V4 titanium alloy and a 3D woven carbon/epoxy composite material. Two bond types with different mechanical strengths were obtained from two different adhesive reticulations, at 50% and 90% of conversion, resulting in longitudinal static strengths of 10 and 39 MPa and transverse strengths of 15 and 35 MPa, respectively. The GPa shock waves were generated using ns-scale intense laser pulses and reaction principles to a confined plasma expansion. Simulations taking into account the laser-matter interaction, plasma relaxation, and non-linear shock wave propagation were conducted to aid interpretation of the experiments. Good correlations were obtained between the experiments and the simulation and between different measurement methods of the mechanical strength (normalized tests vs laser-generated shock waves). Such results open the door toward certification of structural bonding.
Probability techniques for reliability analysis of composite materials
NASA Technical Reports Server (NTRS)
Wetherhold, Robert C.; Ucci, Anthony M.
1994-01-01
Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.
FTIR spectra and mechanical strength analysis of some selected rubber derivatives.
Gunasekaran, S; Natarajan, R K; Kala, A
2007-10-01
Rubber materials have wide range of commercial applications such as, infant diapers, famine hygiene products, drug delivery devices and incontinency products such as rubber tubes, tyres, etc. In the present work, studies on mechanical properties of some selected rubber materials viz., natural rubber (NR), styrene butadiene rubber (SBR), nitrile butadiene rubber (NBR) and ethylene propylene diene monomer (EPDM) have been carried out in three states viz., raw, vulcanized and reinforced. To enhance the quality of rubber elastomers, an attempt is made to prepare new elastomers called polyblends. In the present study an attempt is made to blend NR with NBR and with EPDM. We here report, a novel approach for the evaluation of various physico-mechanical properties such as mechanical strength, tensile strength, elongation and hardness. The method is simple, direct and fast and involves infrared spectral measurements for the evaluation of these properties. With the applications of modern infrared spectroscopy, the mechanical strength of these rubber materials have been analyzed by calculating the internal standards among the methyl and methylene group vibrational frequencies obtained from FTIR spectroscopy. Also the tensile strength measurements carried out by universal testing machine. The results pertaining physico-mechanical properties of the rubber derivatives undertaken in the present study obtained by IR-based method are in good agreement with data resulted from the standard methods.
FTIR spectra and mechanical strength analysis of some selected rubber derivatives
NASA Astrophysics Data System (ADS)
Gunasekaran, S.; Natarajan, R. K.; Kala, A.
2007-10-01
Rubber materials have wide range of commercial applications such as, infant diapers, famine hygiene products, drug delivery devices and incontinency products such as rubber tubes, tyres, etc. In the present work, studies on mechanical properties of some selected rubber materials viz., natural rubber (NR), styrene butadiene rubber (SBR), nitrile butadiene rubber (NBR) and ethylene propylene diene monomer (EPDM) have been carried out in three states viz., raw, vulcanized and reinforced. To enhance the quality of rubber elastomers, an attempt is made to prepare new elastomers called polyblends. In the present study an attempt is made to blend NR with NBR and with EPDM. We here report, a novel approach for the evaluation of various physico-mechanical properties such as mechanical strength, tensile strength, elongation and hardness. The method is simple, direct and fast and involves infrared spectral measurements for the evaluation of these properties. With the applications of modern infrared spectroscopy, the mechanical strength of these rubber materials have been analyzed by calculating the internal standards among the methyl and methylene group vibrational frequencies obtained from FTIR spectroscopy. Also the tensile strength measurements carried out by universal testing machine. The results pertaining physico-mechanical properties of the rubber derivatives undertaken in the present study obtained by IR-based method are in good agreement with data resulted from the standard methods.
NASA Astrophysics Data System (ADS)
Li, Xiaozhao; Qi, Chengzhi; Shao, Zhushan; Ma, Chao
2018-02-01
Natural brittle rock contains numerous randomly distributed microcracks. Crack initiation, growth, and coalescence play a predominant role in evaluation for the strength and failure of brittle rocks. A new analytical method is proposed to predict the strength and failure of brittle rocks containing initial microcracks. The formulation of this method is based on an improved wing crack model and a suggested micro-macro relation. In this improved wing crack model, the parameter of crack angle is especially introduced as a variable, and the analytical stress-crack relation considering crack angle effect is obtained. Coupling the proposed stress-crack relation and the suggested micro-macro relation describing the relation between crack growth and axial strain, the stress-strain constitutive relation is obtained to predict the rock strength and failure. Considering different initial microcrack sizes, friction coefficients and confining pressures, effects of crack angle on tensile wedge force acting on initial crack interface are studied, and effects of crack angle on stress-strain constitutive relation of rocks are also analyzed. The strength and crack initiation stress under different crack angles are discussed, and the value of most disadvantaged angle triggering crack initiation and rock failure is founded. The analytical results are similar to the published study results. Rationality of this proposed analytical method is verified.
Evaluation of the adhesion on the nano-scaled polymeric film systems.
Park, Tae Sung; Park, Ik Keun; Yoshida, Sanichiro
2017-04-01
We applied scanning acoustic microscopy known as the V(z) curve technique to photoresist thin-film systems for the evaluation of the adhesive strength at the film-substrate interface. Through the measurement of the SAW (Surface Acoustic Wave) velocity, the V(z) curve analysis allows us to quantify the stiffness of the film-substrate interface. In addition, we conducted a nano-scratch test to quantify the ultimate strength of the adhesion through the evaluation of the critical load. To vary the adhesive conditions, we prepared thin-film specimens with three different types of pre-coating surface treatments, i.e., oxygen-plasma bombardment, HMDS (Hexametyldisilazane) treatment and untreated. The magnitudes of the quantified stiffness and ultimate strength are found consistent with each other for all the specimens tested, indicating that the pre-coating surface treatment can strengthen both the stiffness and ultimate strength of the adhesion. The results of this study demonstrate the usefulness of the V(Z) analysis as a nondestructive method to evaluate the adhesion strength of nano-structured thin-film systems. Copyright © 2017 Elsevier B.V. All rights reserved.
A method to determine shear adhesive strength of fibrin sealants.
Sierra, D H; Feldman, D S; Saltz, R; Huang, S
1992-01-01
The adhesive strength of fibrin sealants has not been rigorously evaluated to date. The adhesive strength of six different concentrations of cryoprecipitated fibrinogen as well as the commercially available fibrin tissue adhesive Tissucol was tested under controlled conditions utilizing split-thickness skin grafts as the test adherand. This test configuration permitted the modeling of bonding strength for attachment of skin grafts as well as incorporate established engineering test standards for adhesives. An increase in fibrin concentration corresponded with an increase in shear adhesive strength. No significant increases in adhesive strength were attained after 5 min of bonding for all tested concentrations, except for the commercial adhesive, which attained the adhesive strength of an equivalent concentration of cryoprecipitated adhesive after 90 min. The adhesive strength, however, was an order of magnitude less than reported values of the tensile strength of fibrin material for similar concentrations. Therefore, it is important that the surgeon use a sufficiently high fibrinogen concentration for the specific clinical indication. The method of fibrin sealant preparation and/or the compounding adjuncts appear to have an effect on the development of adhesive strength.
NASA Astrophysics Data System (ADS)
Mahedi, Masrur
Aggregates derived from natural sources have been used traditionally as the pavement base materials. But in recent times, the extraction of these natural aggregates has become more labor intensive and costly due to resource depletion and environmental concerns. Thus, the uses of recycled aggregates as the supplementary of natural aggregates are increasing considerably in pavement construction. Use of recycled aggregates such as recycled crushed concrete (RCA) and recycled asphalt pavement (RAP) reduces the rate of natural resource depletion, construction debris and cost. Although recycled aggregates could be used as a viable alternative of conventional base materials, strength characteristics and product variability limit their utility to a great extent. Hence, their applicability is needed to be evaluated extensively based on strength, stiffness and cost factors. But for extensive evaluation, traditionally practiced test methods are proven to be unreasonable in terms of time, cost, reliability and applicability. On the other hand, rapid non-destructive methods have the potential to be less time consuming and inexpensive along with the low variability of test results; therefore improving the reliability of estimated performance of the pavement. In this research work, the experimental program was designed to assess the potential application of stress wave velocity method as a non-destructive test in evaluating recycled base materials. Different combinations of cement treated recycled concrete aggregate (RAP) and recycled crushed concrete (RCA) were used to evaluate the applicability of stress wave velocity method. It was found that, stress wave velocity method is excellent in characterizing the strength and stiffness properties of cement treated base materials. Statistical models, based on P-wave velocity were derived for predicting the modulus of elasticity and compressive strength of different combinations of cement treated RAP, Grade-1 and Grade-2 materials. Two, three and four parameter modeling were also done for characterizing the resilient modulus response. It is anticipated that, derived correlations can be useful in estimating the strength and stiffness response of cement treated base materials with satisfactory level of confidence, if the P-wave velocity remains within the range of 500 ft/sec to 1500 ft/sec.
NASA Technical Reports Server (NTRS)
Stephens, J. R.; Witzke, W. R.
1978-01-01
Thermomechanical processing (TMP) was evaluated as a method of strengthening normally tough iron-12-nickel-reactive metal alloys at cryogenic temperatures. Five iron-12 nickel alloys with reactive metal additions of aluminum, niobium, titanium, vanadium, and aluminum plus niobium were investigated. Primary evaluation was based on the yield strength and fracture toughness of the thermomechanically processed alloys at -196 C.
Scholtes, Vanessa A; Dallmeijer, Annet J; Rameckers, Eugene A; Verschuren, Olaf; Tempelaars, Els; Hensen, Maartje; Becher, Jules G
2008-01-01
Background Until recently, strength training in children with cerebral palsy (CP) was considered to be inappropriate, because it could lead to increased spasticity or abnormal movement patterns. However, the results of recent studies suggest that progressive strength training can lead to increased strength and improved function, but low methodological quality and incomplete reporting on the training protocols hampers adequate interpretation of the results. This paper describes the design and training protocol of a randomized controlled trial to assess the effects of a school-based progressive functional strength training program for children with CP. Methods/Results Fifty-one children with Gross Motor Function Classification Systems levels I to III, aged of 6 to 13 years, were recruited. Using stratified randomization, each child was assigned to an intervention group (strength training) or a control group (usual care). The strength training was given in groups of 4–5 children, 3 times a week, for a period of 12 weeks. Each training session focussed on four exercises out of a 5-exercise circuit. The training load was gradually increased based on the child's maximum level of strength, as determined by the 8 Repetition Maximum (8 RM). To evaluate the effectiveness of the training, all children were evaluated before, during, directly after, and 6 weeks after the intervention period. Primary outcomes in this study were gross motor function (measured with the Gross Motor Function Measure and functional muscle strength tests) and walking ability (measured with the 10-meter, the 1-minute and the timed stair test). Secondary outcomes were lower limb muscle strength (measured with a 6 RM test, isometric strength tests, and a sprint capacity test), mobility (measured with a mobility questionnaire), and sport activities (measured with the Children's Assessment of Participation and Enjoyment). Spasticity and range of motion were assessed to evaluate any adverse events. Conclusion Randomized clinical trials are considered to present the highest level of evidence. Nevertheless, it is of utmost importance to report on the design, the applied evaluation methods, and all elements of the intervention, to ensure adequate interpretation of the results and to facilitate implementation of the intervention in clinical practice if the results are positive. Trial Registration Trial Register NTR1403 PMID:18842125
SBS vs Inhouse Recycling Methods-An Invitro Evaluation
Verma, Jaya Krishanan; Arun; Sundari, Shanta; Chandrasekhar, Shyamala; Kumar, Aravind
2015-01-01
Introduction In today’s world of economic crisis it is not feasible for an orthodontist to replace each and every debonded bracket with a new bracket- quest for an alternative thrives Orthodontist. The concept of recycling bracket for its reuse has evolved over a period of time. Orthodontist can send the brackets to various commercial recycling companies for recycling, but it’s impractical as these are complex procedures and require time and usage of a new bracket would seem more feasible. Thereby, in-house methods have been developed. The aim of the study was to determine the SBS (Shear Bond Strength) and to compare, evaluate the efficiency of in house recycling methods with that of the SBS of new brackets. Materials and Methods Five in–house-recycling procedures-Adhesive Grinding Method, Sandblasting Method, Thermal Flaming Method, Buchman method and Acid Bath Method were used in the present study. Initial part of the study included the use of UV/Vis spectrophotometer where in the absorption level of base of new stainless steel bracket is compared with the base of a recycled bracket. The difference seen in the UV absorbance can be attributed to the presence of adhesive remnant. For each recycling procedure the difference in UV absorption is calculated. New stainless steel brackets and recycled brackets were tested for its shear bond strength with Instron testing machine. Comparisons were made between shear bond strength of new brackets with that of recycled brackets. The last part of the study involved correlating the findings of UV/Vis spectrophotometer with the shear bond strength for each recycling procedure. Results Among the recycled brackets the Sandblasting technique showed the highest shear bond strength (19.789MPa) and the least was shown by the Adhesive Grinding method (13.809MPa). Conclusion The study concludes that sand blasting can be an effective choice among the 5 in house methods of recycling methods. PMID:26501002
Normative Measurements of Grip and Pinch Strengths of 21st Century Korean Population
Shim, Jin Hee; Kim, Jin Soo; Lee, Dong Chul; Ki, Sae Hwi; Yang, Jae Won; Jeon, Man Kyung; Lee, Sang Myung
2013-01-01
Background Measuring grip and pinch strength is an important part of hand injury evaluation. Currently, there are no standardized values of normal grip and pinch strength among the Korean population, and lack of such data prevents objective evaluation of post-surgical recovery in strength. This study was designed to establish the normal values of grip and pinch strength among the healthy Korean population and to identify any dependent variables affecting grip and pinch strength. Methods A cross-sectional study was carried out. The inclusion criterion was being a healthy Korean person without a previous history of hand trauma. The grip strength was measured using a Jamar dynamometer. Pulp and key pinch strength were measured with a hydraulic pinch gauge. Intra-individual and inter-individual variations in these variables were analyzed in a standardized statistical manner. Results There were a total of 336 healthy participants between 13 and 77 years of age. As would be expected in any given population, the mean grip and pinch strength was greater in the right hand than the left. Male participants (137) showed mean strengths greater than female participants (199) when adjusted for age. Among the male participants, anthropometric variables correlated positively with grip strength, but no such correlations were identifiable in female participants in a statistically significant way. Conclusions Objective measurements of hand strength are an important component of hand injury evaluation, and population-specific normative data are essential for clinical and research purposes. This study reports updated normative hand strengths of the South Korean population in the 21st century. PMID:23362480
Proposed test method for and evaluation of wheelchair seating system (WCSS) crashworthiness.
van Roosmalen, L; Bertocci, G; Ha, D R; Karg, P; Szobota, S
2000-01-01
Safety of motor vehicle seats is of great importance in providing crash protection to the occupant. An increasing number of wheelchair users use their wheelchairs as motor vehicle seats when traveling. A voluntary standard requires that compliant wheelchairs be dynamically sled impact tested. However, testing to evaluate the crashworthiness of add-on wheelchair seating systems (WCSS) independent of their wheelchair frame is not addressed by this standard. To address this need, this study developed a method to evaluate the crash-worthiness of WCSS with independent frames. Federal Motor Vehicle Safety Standards (FMVSS) 207 test protocols, used to test the strength of motor vehicle seats, were modified and used to test the strength of three WCSS. Forward and rearward loads were applied at the WCSS center of gravity (CGSS), and a moment was applied at the uppermost point of the seat back. Each of the three tested WCSS met the strength requirements of FMVSS 207. Wheelchair seat-back stiffness was also investigated and compared to motor vehicle seat-back stiffness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellen M. Rabenberg; Brian J. Jaques; Bulent H. Sencer
The mechanical properties of AISI 304 stainless steel irradiated for over a decade in the Experimental Breeder Reactor (EBR-II) were measured using miniature mechanical testing methods. The shear punch method was used to evaluate the shear strengths of the neutron-irradiated steel and a correlation factor was empirically determined to predict its tensile strength. The strength of the stainless steel slightly decreased with increasing irradiation temperature, and significantly increased with increasing dose until it saturated above approximately 5 dpa. Ferromagnetic measurements were used to observe and deduce the effects of the stress-induced austenite to martensite transformation as a result of shearmore » punch testing.« less
ERIC Educational Resources Information Center
Stuebing, Karla K.; Fletcher, Jack M.; Branum-Martin, Lee; Francis, David J.
2012-01-01
This study used simulation techniques to evaluate the technical adequacy of three methods for the identification of specific learning disabilities via patterns of strengths and weaknesses in cognitive processing. Latent and observed data were generated and the decision-making process of each method was applied to assess concordance in…
Complex strength performance in patients with haemophilia A. Method development and testing.
Runkel, B; Kappelhoff, M; Hilberg, T
2015-01-01
The aim of this study was to develop a complex strength measurement method and to apply this new method for the first time in patients with haemophilia (PwH). 20 PwH with severe haemophilia A and 20 controls were included into the study. All subjects completed ten measurements of maximum isometric strength. Furthermore, the 20 control subjects completed re-test-measurements to evaluate the method. As a result, the method showed a high reliability (ICC 0.764 to 0.934). Between the two groups significant reductions in PwH between -(19-35%) were detected, regarding the relative force of the M. triceps brachii (-19%; p = 0.008), M. biceps brachii (-19%; p = 0.031), M. latissimus dorsi (-17%; p = 0.019), M. biceps femoris right (-20%; p = 0.036) and M. quadriceps femoris (right: -29%; p = 0.004; left: -35%; p = 0.002). No differences were found for M. rectus abdominis and in the hand strength. Thus, there is no general deficit in the muscle strength in PwH. The most obvious deficits exist in the upper and lower extremities and in the back muscles. PwH should carry out complex muscle strength training and integrate it early into a comprehensive treatment concept.
Kim, Jae-Hoon; Chae, Soyeon; Lee, Yunhee; Han, Geum-Jun; Cho, Byeong-Hoon
2014-11-01
This study compared the sensitivity of three shear test methods for measuring the shear bond strength (SBS) of resin cement to zirconia ceramic and evaluated the effects of surface treatment methods on the bonding. Polished zirconia ceramic (Cercon base, DeguDent) discs were randomly divided into four surface treatment groups: no treatment (C), airborne-particle abrasion (A), conditioning with Alloy primer (Kuraray Medical Co.) (P) and conditioning with Alloy primer after airborne-particle abrasion (AP). The bond strengths of the resin cement (Multilink N, Ivoclar Vivadent) to the zirconia specimens of each surface treatment group were determined by three SBS test methods: the conventional SBS test with direct filling of the mold (Ø 4 mm × 3 mm) with resin cement (Method 1), the conventional SBS test with cementation of composite cylinders (Ø 4 mm × 3 mm) using resin cement (Method 2) and the microshear bond strength (μSBS) test with cementation of composite cylinders (Ø 0.8 mm × 1 mm) using resin cement (Method 3). Both the test method and the surface treatment significantly influenced the SBS values. In Method 3, as the SBS values increased, the coefficients of variation decreased and the Weibull parameters increased. The AP groups showed the highest SBS in all of the test methods. Only in Method 3 did the P group show a higher SBS than the A group. The μSBS test was more sensitive to differentiating the effects of surface treatment methods than the conventional SBS tests. Primer conditioning was a stronger contributing factor for the resin bond to zirconia ceramic than was airborne-particle abrasion.
Effect of Low-Level Laser Therapy and Strength Training Protocol on Hand Grip by Dynamometry
Barbosa, Rafael; Marcolino, Alexandre; Souza, Vitor; Bertolino, Guilherme; Fonseca, Marisa; Guirro, Rinaldo
2017-01-01
Introduction: The purpose of this study was to investigate the effect of low-level laser therapy (LLLT) – 660 nm and 904 nm - before grip strength protocol in healthy subjects. Methods: The study included 45 healthy volunteers with an average age of 22.7 (±1.4) years, subdivided into the following groups, control group: grip strength training associated with placebo LLLT; 660 nm group: LLLT (660 nm, 20 J/cm2, power of 30 mW, and beam area of 0.06 cm2, continuous, energy 1.2 J, and exposure time 40 seconds per point) before grip strength training and 904 nm group: LLLT (904 nm, 10 J/cm2, peak power of 70 W and 0.13 cm2 beam area, with pulsed beam 9.500 Hz and 30 seconds of exposure time per point and emitted energy 1.2 J) before grip strength training. The LLLT was timed to contact 10 points located in the region of the superficial and deep flexor muscles of the fingers, with a total energy of 12.0 J per session. For the strength training protocol, the volunteer exercised their fingers with the dominant hand on a small table, elbow flexed at 90°, forearm in neutral, using a light extension handle. The Oxford protocol was performed during four weeks. The grip strength was assessed using a dynamometer (Jamar™). The data were evaluated by the analysis of variance (ANOVA) statistical method. Results: In the comparison of intragroup evaluation, only the 904 nm group showed a difference compared to the baseline assessment after 4 weeks (P < 0.05), in the final intergroup evaluation, a difference was observed in the comparison between the control and 904 nm groups Conclusion: In conclusion, LLLT (904 nm) applied before resistance training was effective in gaining grip strength when compared to LLLT (660 nm) and isolated strength training after 4 weeks. PMID:29123629
NASA Astrophysics Data System (ADS)
Manikandan, P.; Balaji, S.; Sukumar, S.; Sivakumar, M.
2017-06-01
This paper presents the strength and behaviour of web stiffened cold formed steel channel column with various types of edge stiffener under axial compression. An accurate finite element model is developed to simulate the tests results of the proposed section. The finite element model is verified by the test results and good correlation is achieved. The failure modes local, distortional, flexural buckling as well as the interaction between these modes is found in this study. The column strength predicted from the parametric study is compared with the nominal strength calculated by using the direct strength method for cold formed steel members. The reliability of this method is evaluated and suitable modification factor is proposed.
Success in the TACP Training Program An Objective Method for Selecting Battlefield Airmen
2009-12-23
rationale and evaluation of the physical training doctrine. J Strength Cond Res. 2009 Jul;23(4):1353-62. Interventions used to improve retention...week training programs on military physical performance. J Strength Cond Res. 2008 Mar;22(2):524-34. Muza SR. Military applications of hypoxic...1 Success in the TACP Training Program An Objective Method for Selecting Battlefield Airmen FINAL REPORT December 23, 2009
Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover
2012-06-01
The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.
Pramodh, N R; Kumar, C N Vijay; Pradeep, M R; Naik, Ravi; Mahesh, C S; Kumari, Manju R
2017-12-01
The aim of this study was to evaluate the tensile strength of die stone incorporated with sodium and calcium hypochlorite as disinfectants. Two commercially available type IV die stone (Kalrock: Kalabhai Karson Pvt., Ltd and Pearlstone: Asian Chemicals) and two commercially available disinfectant solutions (sodium hypochlorite and calcium hypochlorite: Beachem Laboratory Chemical Private Limited, Chennai and Leo Chem Private Limited, Bengaluru) were used in this study, and the tensile strength was measured using Lloyd's Universal Testing Machine. The results show that incorporating the disinfecting solutions decreases the tensile strength of both products. The effect of decreasing tensile strength on type IV gypsum product is seen more in calcium hypochlorite when compared with sodium hypochlorite disinfecting solution, and the tensile strength of Kalrock specimens is higher than Pearlstone specimens after disinfecting with sodium hypochlorite and calcium hypochlorite solution. The statistical results also show significant results in all the groups when compared with the control group. The incorporation of sodium and calcium hypochlorite disinfecting solutions is not an encouraging method for both die materials as it reduces the tensile strength of type IV gypsum product. Tensile strength of Kalstone® die material is superior than Pearlstone® die material after mixing with sodium hypochlorite and calcium hypochlorite. According to the recommendations of Americans with Disability Act (ADA) and the Centers for Disease Control and Prevention, disinfecting the whole cast without or minimal changes in physical and mechanical properties was the motto of the study. The tensile strength in type IV gypsum product plays a most important role in retrieval of cast from impression, especially in narrow tooth preparation. This study reveals that incorporating method of disinfecting solutions is not recommended as it reduces the tensile strength.
Kapoor, Saumya; Balakrishnan, Dhanasekar
2017-01-01
Background For success of any indirect metal restoration, a strong bond between cement and the intaglio surface of metal is imperative. The aim of this study is to evaluate and compare the effect of different surface treatment on the tensile and shear bond strength of different cements with nickel–chromium alloy. Material and Methods 120 premolars were sectioned horizontally parallel to the occlusal surface to expose the dentin. Wax patterns were fabricated for individual tooth followed by casting them in nickel chromium alloy. 60 samples were tested for tensile bond strength, and the remaining 60 for shear bond strength. The samples were divided into three groups (of 20 samples each) as per the following surface treatment: oxidation only, oxidation and sandblasting, or oxidation, sandblasting followed by application of alloy primer. Each group was subdivided into 2 subgroups of 10 samples each, according to the bonding cement i.e RM-GIC and resin cement. Samples were subjected to thermocycling procedure followed by evaluation of bond strength. Results Two-way analyses of variance (ANOVA) was performed to compare the means of tensile and shear bond strength across type of surface treatment and cement, followed by post hoc parametric analysis. For all tests ‘p’ value of less than 0.05 was considered statistically significant. Conclusions The surface treatment of oxidation and sandblasting followed by application of alloy primer offered the maximum tensile and shear bond strength for both RM GIC and resin cement. Resin cement exhibited greater tensile and shear bond strength than RM-GIC for all the three surface treatment methods. Key words:Resin cement, resin modified glass ionomer cement, oxidation, sandblasting, alloy primer, tensile bond strength, shear bond strength, universal testing machine. PMID:28828160
Probabilistic and Possibilistic Analyses of the Strength of a Bonded Joint
NASA Technical Reports Server (NTRS)
Stroud, W. Jefferson; Krishnamurthy, T.; Smith, Steven A.
2001-01-01
The effects of uncertainties on the strength of a single lap shear joint are explained. Probabilistic and possibilistic methods are used to account for uncertainties. Linear and geometrically nonlinear finite element analyses are used in the studies. To evaluate the strength of the joint, fracture in the adhesive and material strength failure in the strap are considered. The study shows that linear analyses yield conservative predictions for failure loads. The possibilistic approach for treating uncertainties appears to be viable for preliminary design, but with several qualifications.
Jerrold E. Winandy; Douglas Herdman
2003-01-01
The purpose of this work was to evaluate the effects of a new boron-nitrogen, phosphate-free fire-rerardant (FR) formulation on the initial strength of No. 1 southern pine 2 by 4 lumber and its potential for in-service thermal degradation. The lumber was evaluated according to Method C of the D 5664 standard test method. The results indicated that for lumber exposed at...
ERIC Educational Resources Information Center
Lakes, Kimberley D.; Swanson, James M.; Riggs, Matt
2012-01-01
Objective: To evaluate the reliability and validity of the English and Spanish versions of the Strengths and Weaknesses of ADHD-symptom and Normal-behavior (SWAN) rating scale. Method: Parents of preschoolers completed both a SWAN and the well-established Strengths and Difficulties Questionnaire (SDQ) on two separate occasions over a span of 3…
Biomechanical monitoring of healing bone based on acoustic emission technology.
Hirasawa, Yasusuke; Takai, Shinro; Kim, Wook-Cheol; Takenaka, Nobuyuki; Yoshino, Nobuyuki; Watanabe, Yoshinobu
2002-09-01
Acoustic emission testing is a well-established method for assessment of the mechanical integrity of general construction projects. The purpose of the current study was to investigate the usefulness of acoustic emission technology in monitoring the yield strength of healing callus during external fixation. Thirty-five patients with 39 long bones treated with external fixation were evaluated for fracture healing by monitoring load for the initiation of acoustic emission signal (yield strength) under axial loading. The major criteria for functional bone union based on acoustic emission testing were (1) no acoustic emission signal on full weightbearing, and (2) a higher estimated strength than body weight. The yield strength monitored by acoustic emission testing increased with the time of healing. The external fixator could be removed safely and successfully in 97% of the patients. Thus, the acoustic emission method has good potential as a reliable method for monitoring the mechanical status of healing bone.
DOT National Transportation Integrated Search
2005-01-01
This report describes work to develop non-destructive testing methods for concrete pavements. Two methods, for pavement thickness and in-place strength estimation, respectively, were developed and evaluated. The thickness estimation method is based o...
Evaluating the Strength of School Tobacco Policies: The Development of a Practical Rating System
ERIC Educational Resources Information Center
Boyce, Jennifer C.; Mueller, Nancy B.; Hogan-Watts, Melissa; Luke, Douglas A.
2009-01-01
Background: School tobacco control policies vary widely in their strength, extensiveness, and enforcement. Currently, no standardized method exists to assess the comprehensiveness of school tobacco policies. The purpose of this study was to develop a new practical rating system for school tobacco policies, assess its reliability, and present…
Spray automated balancing of rotors: Methods and materials
NASA Technical Reports Server (NTRS)
Smalley, Anthony J.; Baldwin, Richard M.; Schick, Wilbur R.
1988-01-01
The work described consists of two parts. In the first part, a survey is performed to assess the state of the art in rotor balancing technology as it applies to Army gas turbine engines and associated power transmission hardware. The second part evaluates thermal spray processes for balancing weight addition in an automated balancing procedure. The industry survey reveals that: (1) computerized balancing equipment is valuable to reduce errors, improve balance quality, and provide documentation; (2) slow-speed balancing is used exclusively, with no forseeable need for production high-speed balancing; (3) automated procedures are desired; and (4) thermal spray balancing is viewed with cautious optimism whereas laser balancing is viewed with concern for flight propulsion hardware. The FARE method (Fuel/Air Repetitive Explosion) was selected for experimental evaluation of bond strength and fatigue strength. Material combinations tested were tungsten carbide on stainless steel (17-4), Inconel 718 on Inconel 718, and Triballoy 800 on Inconel 718. Bond strengths were entirely adequate for use in balancing. Material combinations have been identified for use in hot and cold sections of an engine, with fatigue strengths equivalent to those for hand-ground materials.
NASA Astrophysics Data System (ADS)
El-Tarfawy, S. Y.
2017-10-01
There are various methods to evaluate knitted fabric’s properties; the yarn pulling force is a suitable experimental method to investigate the properties of single jersey knitted fabric.In this study, a frame is attached to the electronic tensile strength tester to fix different single jersey knitted fabrics with different dimensional properties. A hook is connected to the upper load cell in the tensile tester to ravel the first upper course then records the values of the yarn pulling force. In addition to that, the effect of the loop length, yarn count, and raw material on yarn pulling force and specific fabric bursting strength are studied. It is concluded that yarn pulling force has a significant relation with specific fabric bursting strength.
NASA Astrophysics Data System (ADS)
Deni, Glar Donia; Dhaningtyas, Shalihat Afifah; Fajar, Ibnu; Sudarno
2015-12-01
The characterization and evaluation of biodegradable plastic composed of a mixture PVA - carrageenan - chitosan was conducted in this study. Obtained data were then compared to commercial biodegradable plastic. Characteristic of plastic was mechanical tested such as tensile - strength and elongation. Plastic degradation was studied using composting method for 7 days and 14 days. The results showed that the increase carrageenan will decrease tensile-strength and elongation plastic composite. In addition, increase carrageenan would increase the degraded plastics composite.
Yokoo, Takeshi; Serai, Suraj D; Pirasteh, Ali; Bashir, Mustafa R; Hamilton, Gavin; Hernando, Diego; Hu, Houchun H; Hetterich, Holger; Kühn, Jens-Peter; Kukuk, Guido M; Loomba, Rohit; Middleton, Michael S; Obuchowski, Nancy A; Song, Ji Soo; Tang, An; Wu, Xinhuai; Reeder, Scott B; Sirlin, Claude B
2018-02-01
Purpose To determine the linearity, bias, and precision of hepatic proton density fat fraction (PDFF) measurements by using magnetic resonance (MR) imaging across different field strengths, imager manufacturers, and reconstruction methods. Materials and Methods This meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic literature search identified studies that evaluated the linearity and/or bias of hepatic PDFF measurements by using MR imaging (hereafter, MR imaging-PDFF) against PDFF measurements by using colocalized MR spectroscopy (hereafter, MR spectroscopy-PDFF) or the precision of MR imaging-PDFF. The quality of each study was evaluated by using the Quality Assessment of Studies of Diagnostic Accuracy 2 tool. De-identified original data sets from the selected studies were pooled. Linearity was evaluated by using linear regression between MR imaging-PDFF and MR spectroscopy-PDFF measurements. Bias, defined as the mean difference between MR imaging-PDFF and MR spectroscopy-PDFF measurements, was evaluated by using Bland-Altman analysis. Precision, defined as the agreement between repeated MR imaging-PDFF measurements, was evaluated by using a linear mixed-effects model, with field strength, imager manufacturer, reconstruction method, and region of interest as random effects. Results Twenty-three studies (1679 participants) were selected for linearity and bias analyses and 11 studies (425 participants) were selected for precision analyses. MR imaging-PDFF was linear with MR spectroscopy-PDFF (R 2 = 0.96). Regression slope (0.97; P < .001) and mean Bland-Altman bias (-0.13%; 95% limits of agreement: -3.95%, 3.40%) indicated minimal underestimation by using MR imaging-PDFF. MR imaging-PDFF was precise at the region-of-interest level, with repeatability and reproducibility coefficients of 2.99% and 4.12%, respectively. Field strength, imager manufacturer, and reconstruction method each had minimal effects on reproducibility. Conclusion MR imaging-PDFF has excellent linearity, bias, and precision across different field strengths, imager manufacturers, and reconstruction methods. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 2, 2017.
Evaluation of Silicon Nitride for Brayton Turbine Wheel Application
NASA Technical Reports Server (NTRS)
Freedman, Marc R.
2008-01-01
Silicon nitride (Si3N4) is being evaluated as a risk-reduction alternative for a Jupiter Icy Moons Orbiter Brayton turbine wheel in the event that the Prometheus program design requirements exceed the creep strength of the baseline metallic superalloys. Five Si3N4 ceramics, each processed by a different method, were screened based on the Weibull distribution of bend strength at 1700 F (927 C). Three of the Si3N4 ceramics, Honeywell AS800, Kyocera SN282, and Saint-Gobain NT154, had bend strengths in excess of 87 ksi (600 MPa) at 1700 F (927 C). These were chosen for further assessment and consideration for future subcomponent and component fabrication and testing.
NASA Astrophysics Data System (ADS)
Lee, Byung Jun; Kim, Min Gun
2003-04-01
To develop a method of accelerating the strength evaluation of hard tissue replacement materials (Ti-6Al-4V alloy) with an electrochemical approach in the short term, corrosion tests were carried out on Ti-6Al-4V alloy) by means of applying a uniform current to a simulated physiological environment and the potental difference was scanned to check the variations in the resistance of the specimens. As a result, the corrosion behavior was monitored by scanning the potential difference and an empirical formula for controlling the corrosion behavior of the Ti-6Al-4V alloy in the simulated physiological environment was proposed.
Lamarca, F; Carrero, J J; Rodrigues, J C D; Bigogno, F G; Fetter, R L; Avesani, C M
2014-07-01
The prevalence of sarcopenia on elderly maintenance hemodialysis (MHD) has been scarcely investigated. To investigate the prevalence of decreased muscle mass and strength alone or combined (true sarcopenia) in elderly patients on MHD according to different methods and cutoff limits. Additionally, we evaluated the agreement between dual energy x-ray absorptiometry (DXA) and surrogate methods for the assessment of muscle mass. Observational and cross-sectional study. Non-institutionalized 102 elderly (age > 60 years) patients on MHD. Sarcopenia was considered when the patient fit one criteria for low muscle mass assessed by DXA, bioelectrical impedance (BIA), sum of skinfold thicknesses (SKF), calf circumference and mid-arm muscle circumference (MAMC) and one for low muscle strength evaluated by handgrip dynamometer. Decreased muscle strength was found in 85% of the patients. The prevalence of decreased muscle mass varied from 4 to 73.5% and of sarcopenia (decreased muscle mass and strength combined) from 4 to 63%, depending on the method and cutoff limit applied. A small percentage of patients (2 to 15%) were classified as sarcopenic by more than one diagnostic criteria. The agreement between DXA and the surrogate methods to assess muscle mass showed better kappa coefficients with BIA (r=0.36; P<0.01) and SKF (r=0.40; P<0.01). A wide prevalence of sarcopenia is observed depending on the method and cutoff limit applied. This may limit extrapolate on to clinical practice. BIA and SKF were the surrogate methods to assess muscle mass with the best concordance with DXA in elderly MHD patients.
ERIC Educational Resources Information Center
Seguin, Rebecca A.; Heidkamp-Young, Eleanor; Kuder, Julia; Nelson, Miriam E.
2012-01-01
Background: Strength training (ST) is an important health behavior for aging women; it helps maintain strength and function and reduces risk for chronic diseases. This study assessed change in physical fitness following participation in a ST program implemented and evaluated by community leaders. Method: The StrongWomen Program is a nationally…
ERIC Educational Resources Information Center
Lin, Jie
2006-01-01
The Bookmark standard-setting procedure was developed to address the perceived problems with the most popular method for setting cut-scores: the Angoff procedure (Angoff, 1971). The purposes of this article are to review the Bookmark procedure and evaluate it in terms of Berk's (1986) criteria for evaluating cut-score setting methods. The…
In vitro analysis of shear bond strength and adhesive remnant index of different metal brackets
Henkin, Fernanda de Souza; de Macêdo, Érika de Oliveira Dias; Santos, Karoline da Silva; Schwarzbach, Marília; Samuel, Susana Maria Werner; Mundstock, Karina Santos
2016-01-01
ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface. PMID:28125142
Method, apparatus and system to compensate for drift by physically unclonable function circuitry
Hamlet, Jason
2016-11-22
Techniques and mechanisms to detect and compensate for drift by a physically uncloneable function (PUF) circuit. In an embodiment, first state information is registered as reference information to be made available for subsequent evaluation of whether drift by PUF circuitry has occurred. The first state information is associated with a first error correction strength. The first state information is generated based on a first PUF value output by the PUF circuitry. In another embodiment, second state information is determined based on a second PUF value that is output by the PUF circuitry. An evaluation of whether drift has occurred is performed based on the first state information and the second state information, the evaluation including determining whether a threshold error correction strength is exceeded concurrent with a magnitude of error being less than the first error correction strength.
Michie, Susan; West, Robert; Sheals, Kate; Godinho, Cristina A
2018-03-01
Behavior change interventions typically contain multiple potentially active components: behavior change techniques (BCTs). Identifying which specific BCTs or BCT combinations have the potential to be effective for a given behavior in a given context presents a major challenge. The aim of this study was to review the methods that have been used to identify effective BCTs for given behaviors in given contexts and evaluate their strengths and limitations. A scoping review was conducted of studies that had sought to identify effective BCTs. Articles referring to "behavio(u)r change technique(s)" in the abstract/text were located, and ones that involved identification of effective BCTs were selected. The methods reported were coded. The methods were analyzed in general terms using "PASS" criteria: Practicability (facility to apply the method appropriately), Applicability (facility to generalize from findings to contexts and populations of interest), Sensitivity (facility to identify effective BCTs), and Specificity (facility to rule out ineffective BCTs). A sample of 10% of the studies reviewed was then evaluated using these criteria to assess how far the strengths and limitations identified in principle were borne out in practice. One hundred and thirty-five studies were identified. The methods used in those studies were experimental manipulation of BCTs, observational studies comparing outcomes in the presence or absence of BCTs, meta-analyses of BCT comparisons, meta-regressions evaluating effect sizes with and without specific BCTs, reviews of BCTs found in effective interventions, and meta-classification and regression trees. The limitations of each method meant that only weak conclusions could be drawn regarding the effectiveness of specific BCTs or BCT combinations. Methods for identifying effective BCTs linked to target behavior and context all have important inherent limitations. A strategy needs to be developed that can systematically combine the strengths of the different methods and that can link these constructs in an ontology of behavior change interventions.
Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo
2017-12-01
Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.
Dielectric breakdown of additively manufactured polymeric materials
Monzel, W. Jacob; Hoff, Brad W.; Maestas, Sabrina S.; ...
2016-01-11
Dielectric strength testing of selected Polyjet-printed polymer plastics was performed in accordance with ASTM D149. This dielectric strength data is compared to manufacturer-provided dielectric strength data for selected plastics printed using the stereolithography (SLA), fused deposition modeling (FDM), and selective laser sintering (SLS) methods. Tested Polyjet samples demonstrated dielectric strengths as high as 47.5 kV/mm for a 0.5 mm thick sample and 32.1 kV/mm for a 1.0 mm sample. As a result, the dielectric strength of the additively manufactured plastics evaluated as part of this study was lower than the majority of non-printed plastics by at least 15% (with themore » exception of polycarbonate).« less
Dielectric breakdown of additively manufactured polymeric materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monzel, W. Jacob; Hoff, Brad W.; Maestas, Sabrina S.
Dielectric strength testing of selected Polyjet-printed polymer plastics was performed in accordance with ASTM D149. This dielectric strength data is compared to manufacturer-provided dielectric strength data for selected plastics printed using the stereolithography (SLA), fused deposition modeling (FDM), and selective laser sintering (SLS) methods. Tested Polyjet samples demonstrated dielectric strengths as high as 47.5 kV/mm for a 0.5 mm thick sample and 32.1 kV/mm for a 1.0 mm sample. As a result, the dielectric strength of the additively manufactured plastics evaluated as part of this study was lower than the majority of non-printed plastics by at least 15% (with themore » exception of polycarbonate).« less
Assessing Vowel Centralization in Dysarthria: A Comparison of Methods
ERIC Educational Resources Information Center
Fletcher, Annalise R.; McAuliffe, Megan J.; Lansford, Kaitlin L.; Liss, Julie M.
2017-01-01
Purpose: The strength of the relationship between vowel centralization measures and perceptual ratings of dysarthria severity has varied considerably across reports. This article evaluates methods of acoustic-perceptual analysis to determine whether procedural changes can strengthen the association between these measures. Method: Sixty-one…
Skills Methods to Prevent Smoking.
ERIC Educational Resources Information Center
Schinke, Steven Paul; And Others
1986-01-01
Describes an evaluation of the added value of skills methods for preventing smoking with sixth-grade students from two schools. Skills conditions subjects learned problem-solving, self-instruction, and interpersonal communication methods. The article discusses the strengths, limits, and implications of the study for other smoking prevention…
Porosimetric, Thermal and Strength Tests of Aerated and Nonaerated Concretes
NASA Astrophysics Data System (ADS)
Strzałkowski, Jarosław; Garbalińska, Halina
2017-10-01
The paper presents the results of porosimetry tests of lightweight concretes, obtained with three research methods. Impact of different porosity structures on the basic thermal and strength properties was also evaluated. Tests were performed, using the pressure gauge method on fresh concrete mixes, as well as using the mercury porosimetry test and optic RapidAir method on specimens prepared from mature composites. The study was conducted on lightweight concretes, based on expanded clay aggregate and fly ash aggregate, in two variants: with non-aerated and aerated cement matrix. In addition, two reference concretes, based on normal aggregate, were prepared, also in two variants of matrix aeration. Changes in thermal conductivity λ and volumetric specific heat cv throughout the first three months of curing of the concretes were examined. Additionally, tests for compressive strength on cubic samples were performed during the first three months of curing. It was found that the pressure gauge method, performed on a fresh mix, gave lowered values of porosity, compared to the other methods. The mercury porosity tests showed high sensitivity in evaluation of pores smaller than 30μm. Unfortunately, this technique is not suitable for analysing pores greater than 300μm. On the other hand, the optical method proves good in evaluation of large pores, greater than 300μm. The paper also presents results of correlation of individual methods of porosity testing. A consolidated graph of the pore structure, derived from both mercury and optical methods, was presented, too. For the all of six tested concretes, differential graphs of porosity, prepared with both methods, show a very broad convergence. The thermal test results indicate usefulness of aeration of the cement matrix of the composites based on lightweight aggregates for the further reduction of the thermal conductivity coefficient λ of the materials. The lowest values of the λ coefficient were obtained for the aerated concretes based of fly ash aggregate. A diminishing influence of aeration on the volumetric heat capacity cv is clearly seen. Simultaneous aeration of the matrix and use of lightweight aggregates brought about also a significant decrease in the average compressive strength fcm of the tested composites.
Evaluation of rotator cuff muscle strength in healthy individuals
Cortez, Paulo José Oliveira; Tomazini, José Elias
2015-01-01
OBJECTIVE: To compare the strength generated by the rotator muscles of the shoulder joint between the right upper limb and left upper limb among healthy individuals. METHODS: To evaluate the muscle strength of upper limbs from isometric contractions in the horizontal direction (rotation) an isometric dynamometer was used, equipped with transducers, signal conditioning, a data acquisition board, and finally, a computer. Study participants were 22 male military subjects, aged between 18 and 19 years old, body mass between 57.7 and 93.0 kg (71.8 ± 9.45 kg) and height between 1.67 and 1.90 m (1.75 ± 0.06 m), healthy and without clinical diseases or any type of orthopedic injury in the muscle skeletal system. RESULTS: The internal rotation in the right upper limb (RUL) was higher than the average strength of internal rotation in the left upper limb (LUL) (p = 0.723). The external rotation strength in RUL was lower than the average strength of external rotation in the LUL (p=0.788). No statistical difference was observed by comparing the strength values of all isometric strength tests. CONCLUSION: For the sample and methodology used to assess muscle strength, there was no statistical difference between the strength generated by the muscles of the rotator cuff of the right and left upper limbs. Experimental Study. PMID:26207091
Ozkir, Serhat Emre; Yilmaz, Burak; Unal, Server Mutluay; Culhaoglu, Ahmet; Kurkcuoglu, Isin
2018-01-01
Objective: The objective of this study is the effect of different heat polymerization conditions on the strength of polymethyl methacrylate (PMMA) resin base is unknown. Distinguishing one method that provides improved mechanical properties may be beneficial to the clinical success of complete and partial dentures and overdentures. The purpose of this study was to evaluate the effect of different polymerization methods on the flexural strength of a dental PMMA resin. Materials and Methods: Forty PMMA specimens (64 mm × 10 mm × 4 mm) were prepared with 4 different polymerization methods (n = 10); heat polymerization at 74°C for 9 h, at 100°C for 40 min, and with 620 kPa pressure at 100°C for 20 min. The remaining group of specimens was microwave polymerized at 180 W for 6 min. All specimens were thermocycled at 5°C and 55°C for 5000 times. Three-point flexure test was used to measure the flexural strength of specimens. One-way ANOVA and Tukey Honestly Significant Difference were applied to analyze the differences in flexural strengths (α = 0.05). Results: The flexural strength of heat-polymerized groups was similar. The flexural strength of microwave polymerized group was significantly different and lower than the other groups (P < 0.05). Conclusion: Polymerizing conventional heat-polymerizing PMMA resin with microwave energy resulted in a significant decrease in flexural strength. The results of this study suggest that clinicians may benefit from using heat polymerization when processing PMMA denture bases instead of microvawe polymerization when tested brand is used. PMID:29657535
Samadi, Firoza; Jaiswal, JN; Saha, Sonali
2014-01-01
ABSTRACT% Aim: To compare the effect of different chemical solvents on glass fiber reinforced posts and to study the effect of these solvents on the shear bond strength of glass fiber reinforced post to core material. Materials and methods: This study was conducted to evaluate the effect of three chemical solvents, i.e. silane coupling agent, 6% H2O2 and 37% phosphoric acid on the shear bond strength of glass fiber post to a composite resin restorative material. The changes in post surface characteristics after different treatments were also observed, using scanning electron microscopy (SEM) and shear bond strength was analyzed using universal testing machine (UTM). Results: Surface treatment with hydrogen peroxide had greatest impact on the post surface followed by 37% phosphoric acid and silane. On evaluation of the shear bond strength, 6% H2O2 exhibited the maximum shear bond strength followed in descending order by 37% phosphoric acid and silane respectively. Conclusion: The surface treatment of glass fiber post enhances the adhesion between the post and composite resin which is used as core material. Failure of a fiber post and composite resin core often occurs at the junction between the two materials. This failure process requires better characterization. How to cite this article: Sharma A, Samadi F, Jaiswal JN, Saha S. A Comparative Evaluation of Effect of Different Chemical Solvents on the Shear Bond Strength of Glass Fiber Reinforced Post to Core Material. Int J Clin Pediatr Dent 2014;7(3):192-196. PMID:25709300
Kargarfard, Mehdi; Dehghadani, Mehdi; Ghias, Reza
2013-01-01
This study was to evaluate the effect of a period of aquatic exercise therapy on muscle strength and joints range of motion in hemophilia patients. This was a semiexperimental, pretest, post-test study with a control group. This semi-experimental study comprised twenty men suffering moderate hemophilia were selected by convenience sampling method from patients of a referral hospital. They were randomly assigned to intervention and control groups of equal number. The hemophilia patients who were referred to Sayedo-Shohada Hospital enrolled in this study. Twenty men suffering moderate hemophilia were selected using convenience sampling method and then divided randomly into intervention and control groups (10 patients in each group). Subjects of aquatic exercise therapy group underwent activity in water in three sessions (45-60 minutes) per week for 8 weeks, while the control group was only under follow-up and during this period did not experience any effective physical activity. The patients' muscle strength and joint range of motion were evaluated through standard laboratory tools, using an isokinetic dynamometer (Biodex, Systems III) and a standard goniometer in the beginning and at end of the study. Finally, data was analyzed using analysis of covariance (ANCOVA). The strength of the muscles around the knee joint (to perform extension and flexion movements) increased significantly in the case group while the control group experienced a significant reduction of strength in left leg, but in right leg remarkable change was observed. Range of motion in all joints was improved in the case group, while the control group did not improve significantly. The results showed that aquatic exercise therapy can be a useful method to improve joints' strength and range of motion in hemophilia patients in order to improve their daily functioning and quality of life.
Prananingrum, Widyasri; Tomotake, Yoritoki; Naito, Yoshihito; Bae, Jiyoung; Sekine, Kazumitsu; Hamada, Kenichi; Ichikawa, Tetsuo
2016-08-01
The prosthetic applications of titanium have been challenging because titanium does not possess suitable properties for the conventional casting method using the lost wax technique. We have developed a production method for biomedical application of porous titanium using a moldless process. This study aimed to evaluate the physical and mechanical properties of porous titanium using various particle sizes, shapes, and mixing ratio of titanium powder to wax binder for use in prosthesis production. CP Ti powders with different particle sizes, shapes, and mixing ratios were divided into five groups. A 90:10wt% mixture of titanium powder and wax binder was prepared manually at 70°C. After debinding at 380°C, the specimen was sintered in Ar at 1100°C without a mold for 1h. The linear shrinkage ratio of sintered specimens ranged from 2.5% to 14.2%. The linear shrinkage ratio increased with decreasing particle size. While the linear shrinkage ratio of Groups 3, 4, and 5 were approximately 2%, Group 1 showed the highest shrinkage of all. The bending strength ranged from 106 to 428MPa under the influence of porosity. Groups 1 and 2 presented low porosity followed by higher strength. The shear bond strength ranged from 32 to 100MPa. The shear bond strength was also particle-size dependent. The decrease in the porosity increased the linear shrinkage ratio and bending strength. Shrinkage and mechanical strength required for prostheses were dependent on the particle size and shape of titanium powders. These findings suggested that this production method can be applied to the prosthetic framework by selecting the material design. Copyright © 2016 Elsevier Ltd. All rights reserved.
Computer Aided Evaluation of Higher Education Tutors' Performance
ERIC Educational Resources Information Center
Xenos, Michalis; Papadopoulos, Thanos
2007-01-01
This article presents a method for computer-aided tutor evaluation: Bayesian Networks are used for organizing the collected data about tutors and for enabling accurate estimations and predictions about future tutor behavior. The model provides indications about each tutor's strengths and weaknesses, which enables the evaluator to exploit strengths…
NASA Astrophysics Data System (ADS)
Soni, Sourabh Kumar; Thomas, Benedict
2018-04-01
The term "weldability" has been used to describe a wide variety of characteristics when a material is subjected to welding. In our analysis we perform experimental investigation to estimate the tensile strength of welded joint strength and then optimization of welding process parameters by using taguchi method and Artificial Neural Network (ANN) tool in MINITAB and MATLAB software respectively. The study reveals the influence on weldability of steel by varying composition of steel by mechanical characterization. At first we prepare the samples of different grades of steel (EN8, EN 19, EN 24). The samples were welded together by metal inert gas welding process and then tensile testing on Universal testing machine (UTM) was conducted for the same to evaluate the tensile strength of the welded steel specimens. Further comparative study was performed to find the effects of welding parameter on quality of weld strength by employing Taguchi method and Neural Network tool. Finally we concluded that taguchi method and Neural Network Tool is much efficient technique for optimization.
Wnuk, Marcin
2017-01-01
This study verifies the psychometric properties of the Santa Clara Strength of Religious Faith Questionnaire (SCSORFQ). This measure consists of 10 items regarding strength of religious faith, regardless of religious denomination or affiliation. Participants were 177 students from Chile and 393 students from Poland. The SCSORFQ method is a reliable measure with good internal consistency evaluated by the α-Cronbach coefficient. Factor analysis statistically confirmed the unidimensional structure of the SCSORFQ. The strength of religious faith in both student groups was moderate to strong correlated with public or private aspects of religiousness and strong correlated with spiritual experiences. It was weakly correlated with the cognitive indicator of well-being as satisfaction with life as well as with existential variables like hope and meaning of life. The results confirm that the SCSORFQ is psychometrically sound and is therefore recommended for use by researchers studying the construct of religiousness.
Repeat work bouts increase thermal strain for Australian firefighters working in the heat
Walker, Anthony; Argus, Christos; Driller, Matthew; Rattray, Ben
2015-01-01
Background: Firefighters regularly re-enter fire scenes during long duration emergency events with limited rest between work bouts. It is unclear whether this practice is impacting on the safety of firefighters. Objectives:To evaluate the effects of multiple work bouts on firefighter physiology, strength, and cognitive performance when working in the heat. Methods: Seventy-seven urban firefighters completed two 20-minute simulated search and rescue tasks in a heat chamber (105 ± 5°C), separated by a 10-minute passive recovery. Core and skin temperature, rate of perceived exertion (RPE), thermal sensation (TS), grip strength, and cognitive changes between simulations were evaluated. Results: Significant increases in core temperature and perceptual responses along with declines in strength were observed following the second simulation. No differences for other measures were observed. Conclusions: A significant increase in thermal strain was observed when firefighters re-entered a hot working environment. We recommend that longer recovery periods or active cooling methods be employed prior to re-entry. PMID:25849044
ERIC Educational Resources Information Center
Glennen, Sharon
2015-01-01
Purpose: This study aimed to determine the relative strengths and weaknesses in language and verbal short-term memory abilities of school-age children who were adopted from Eastern Europe. Method: Children adopted between 1;0 and 4;11 (years;months) of age were assessed with the Clinical Evaluation of Language Fundamentals-Preschool, Second…
ERIC Educational Resources Information Center
Ishida, Junichi
1997-01-01
Examines the effects of a teaching strategy in which fifth-grade students evaluated the strengths or weaknesses of solution methods to pattern finding problems, including an experimental and control group each consisting of 34 elementary students, in Japan. The experimental group showed a significantly better performance on the retention test…
Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu
2016-07-01
[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.
Quantitative ultrasonic evaluation of engineering properties in metals, composites and ceramics
NASA Technical Reports Server (NTRS)
Vary, A.
1980-01-01
Ultrasonic technology from the perspective of nondestructive evaluation approaches to material strength prediction and property verification is reviewed. Emergent advanced technology involving quantitative ultrasonic techniques for materials characterization is described. Ultrasonic methods are particularly useful in this area because they involve mechanical elastic waves that are strongly modulated by the same morphological factors that govern mechanical strength and dynamic failure processes. It is emphasized that the technology is in its infancy and that much effort is still required before all the available techniques can be transferred from laboratory to industrial environments.
Kargarfard, Mehdi; Dehghadani, Mehdi; Ghias, Reza
2013-01-01
Background: This study was to evaluate the effect of a period of aquatic exercise therapy on muscle strength and joints range of motion in hemophilia patients. Methods: This was a semiexperimental, pretest, post-test study with a control group. This semi-experimental study comprised twenty men suffering moderate hemophilia were selected by convenience sampling method from patients of a referral hospital. They were randomly assigned to intervention and control groups of equal number. The hemophilia patients who were referred to Sayedo-Shohada Hospital enrolled in this study. Twenty men suffering moderate hemophilia were selected using convenience sampling method and then divided randomly into intervention and control groups (10 patients in each group). Subjects of aquatic exercise therapy group underwent activity in water in three sessions (45-60 minutes) per week for 8 weeks, while the control group was only under follow-up and during this period did not experience any effective physical activity. The patients’ muscle strength and joint range of motion were evaluated through standard laboratory tools, using an isokinetic dynamometer (Biodex, Systems III) and a standard goniometer in the beginning and at end of the study. Finally, data was analyzed using analysis of covariance (ANCOVA). Results: The strength of the muscles around the knee joint (to perform extension and flexion movements) increased significantly in the case group while the control group experienced a significant reduction of strength in left leg, but in right leg remarkable change was observed. Range of motion in all joints was improved in the case group, while the control group did not improve significantly. Conclusion: The results showed that aquatic exercise therapy can be a useful method to improve joints’ strength and range of motion in hemophilia patients in order to improve their daily functioning and quality of life. PMID:23412736
NASA Technical Reports Server (NTRS)
Sanchez, Christopher M.
2011-01-01
NASA White Sands Test Facility (WSTF) is leading an evaluation effort in advanced destructive and nondestructive testing of composite pressure vessels and structures. WSTF is using progressive finite element analysis methods for test design and for confirmation of composite pressure vessel performance. Using composite finite element analysis models and failure theories tested in the World-Wide Failure Exercise, WSTF is able to estimate the static strength of composite pressure vessels. Additionally, test and evaluation on composites that have been impact damaged is in progress so that models can be developed to estimate damage tolerance and the degradation in static strength.
Standard methods for filled hole tension testing of textile composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Masters, J. E.
1995-01-01
The effects of two test specimen geometry parameters, the specimen width and W/D ratio, on filled-hole tensile strength were determined for textile composite materials. Test data generated by Boeing and Lockheed on 2-D and 3-D braids, and 3-D weaves were used to make these evaluations. The investigation indicated that filled-hole tensile-strength showed little sensitivity to either parameter. Test specimen configurations used in open-hole tension tests, such as those suggested by ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates or those proposed by MIL-HDBK-17-lD should provide adequate results for material comparisons studies. Comparisons of the materials' open-hole and filled-hole tensile strengths indicated that the latter were generally lower than the former. The 3-D braids were the exception; their filled-hole strengths were unexpected larger than their open-hole strengths. However, these increases were small compared to the scatter in the data. Thus, filled hole tension may be a critical design consideration for textile composite materials.
Zhang, Na; Liu, Xiaoming; Sun, Henghu; Li, Longtu
2011-01-15
Red mud is generated from alumina production, and its disposal is currently a worldwide problem. In China, large quantities of red mud derived from bauxite calcination method are being discharged annually, and its utilization has been an urgent topic. This experimental research was to evaluate the feasibility of blends red mud derived from bauxite calcination method with other industrial wastes for use as a cementitious material. The developed cementitious material containing 30% of the bauxite-calcination-method red mud possessed compressive strength properties at a level similar to normal Portland cement, in the range of 45.3-49.5 MPa. Best compressive strength values were demonstrated by the specimen RSFC2 containing 30% bauxite-calcination-method red mud, 21% blast-furnace slag, 10% fly ash, 30% clinker, 8% gypsum and 1% compound agent. The mechanical and physical properties confirm the usefulness of RSFC2. The hydration characteristics of RSFC2 were characterized by XRD, FTIR, (27)Al MAS-NMR and SEM. As predominant hydration products, ettringite and amorphous C-S-H gel are principally responsible for the strength development of RSFC2. Comparing with the traditional production for ordinary Portland cement, this green technology is easier to be implemented and energy saving. This paper provides a key solution to effectively utilize bauxite-calcination-method red mud. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zenkov, E. V.
2018-01-01
Two methods are given in the article by considering the type of stressed-Deformed state (SDS) based on equations limit condition and analyzing the results of laboratory tests of special specimens for mechanical testing, focus having destruction thereof in the same view of SDS as in focus possible destruction of the structural member. The considered limited use of these methods in terms of considering physically consistent strength criterion type Pisarenko-Lebedev. A revised design-experimental procedure for determining the strength of the material of the structure, combining therein the elements of these two methods, consisting in determining the strength parameters of construction material, entering criterion equation Pisarenko-Lebedev, considering the actual appearance of the region-of-interest SDS structure. The implementation of the procedure is performed on the basis of the selection of the respective experimental laboratory specimens for mechanical testing, plan SDS in working zone coinciding with a SDS: structure whose strength is evaluated. The refinement process limit state equations demonstrated in determining 50CrV4 steel strength parameters, being in a state of biaxial stretching. Design-experimentally determined by, that steel for a given voltage limit value is almost a quarter of its value is reduced compared to the conventional tensile strength. value is reduced compared to the conventional tensile strength.
Microsurgical Versus Conventional Skin Closure in the Laboratory Rat (Rattus norvegicus)
microscope using 6/0 monocryl. Wound strength was measured using a published method. A harvested incision was suspended with forceps and water was slowly...evaluated histologically using published methods to examine vascularization, fibroblast proliferation, inflammation and epithelialization. Results
A method to screen and evaluate tissue adhesives for joint repair applications
2012-01-01
Background Tissue adhesives are useful means for various medical procedures. Since varying requirements cause that a single adhesive cannot meet all needs, bond strength testing remains one of the key applications used to screen for new products and study the influence of experimental variables. This study was conducted to develop an easy to use method to screen and evaluate tissue adhesives for tissue engineering applications. Method Tissue grips were designed to facilitate the reproducible production of substrate tissue and adhesive strength measurements in universal testing machines. Porcine femoral condyles were used to generate osteochondral test tissue cylinders (substrates) of different shapes. Viability of substrates was tested using PI/FDA staining. Self-bonding properties were determined to examine reusability of substrates (n = 3). Serial measurements (n = 5) in different operation modes (OM) were performed to analyze the bonding strength of tissue adhesives in bone (OM-1) and cartilage tissue either in isolation (OM-2) or under specific requirements in joint repair such as filling cartilage defects with clinical applied fibrin/PLGA-cell-transplants (OM-3) or tissues (OM-4). The efficiency of the method was determined on the basis of adhesive properties of fibrin glue for different assembly times (30 s, 60 s). Seven randomly generated collagen formulations were analyzed to examine the potential of method to identify new tissue adhesives. Results Viability analysis of test tissue cylinders revealed vital cells (>80%) in cartilage components even 48 h post preparation. Reuse (n = 10) of test substrate did not significantly change adhesive characteristics. Adhesive strength of fibrin varied in different test settings (OM-1: 7.1 kPa, OM-2: 2.6 kPa, OM-3: 32.7 kPa, OM-4: 30.1 kPa) and was increasing with assembly time on average (2.4-fold). The screening of the different collagen formulations revealed a substance with significant higher adhesive strength on cartilage (14.8 kPa) and bone tissue (11.8 kPa) compared to fibrin and also considerable adhesive properties when filling defects with cartilage tissue (23.2 kPa). Conclusion The method confirmed adhesive properties of fibrin and demonstrated the dependence of adhesive properties and applied settings. Furthermore the method was suitable to screen for potential adhesives and to identify a promising candidate for cartilage and bone applications. The method can offer simple, replicable and efficient evaluation of adhesive properties in ex vivo specimens and may be a useful supplement to existing methods in clinical relevant settings. PMID:22984926
Kusakabe, Shusuke; Rawls, H Ralph; Hotta, Masato
2016-03-01
To evaluate thin-film bond strength between a bonding agent and human dentin, using a scratch test, and the characteristics and accuracy of measurement. One-step bonding agents (BeautiBond; Bond Force; Adper Easy Bond; Clearfil tri-S Bond) and two-step bonding agents (Cleafil SE Bond; FL-Bond II) were investigated in this study. Flat dentin surfaces were prepared for extracted human molars. The dentin surfaces were ground and bonding agents were applied and light cured. The thin-film bond strength test of the specimens was evaluated by the critical load at which the coated bonding agent failed and dentin appeared. The scratch mark sections were then observed under a scanning electron microscope. Indentation hardness was evaluated by the variation in depth under an applied load of 10gf. Data were compared by one-way ANOVA with the Scheffé's post hoc multiple comparison test (p<0.05). In addition, thin-film bond strength and indentation hardness were analyzed using analysis of correlation and covariance. The thin-film bond strength of two-step bonding agents were found to be significantly higher than that of one-step bonding agents with small standard deviations. Scratch marks consistently showed adhesive failure in the vicinity of the bonding agent/dentin interface. The indentation hardness showed a trend that two-step bonding agents have greater hardness than one-step bonding agents. A moderately significant correlation (r(2)=0.31) was found between thin-film bond strength and indentation hardness. Thin-film bond strength test is a valid and reliable means of evaluating bond strength in the vicinity of the adhesive interface and is more accurate than other methods currently in use. Further, the thin-film bond strength is influenced by the hardness of the cued bonding agent. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jong, H.L.
1988-01-01
The first objective was to perform a critical evaluation of the recently proposed steady-state analysis methodology for evaluation of post-liquefaction stability of potentially liquefiable soils. This analysis procedure is based on direct comparison between the in-situ undrained residual (steady state) strength of soils in an embankment or foundation, and the driving shear stresses in these soils. A laboratory investigation was performed to investigate factors affecting steady-state strengths, and also to evaluate the validity of assumptions involved in correcting the results of laboratory steady-state strength tests on undisturbed samples for effects of sampling disturbance in order to estimate in-situ strengths. Next,more » a field case study was performed using the steady-state analysis and testing methodologies to analyze Lower San Fernando Dam, which suffered a liquefaction-induced slope failure as a results of a 1971 earthquake. This leads to the second objective which was to extend the Lower San Fernando Dam case study to consideration of analysis methods used to evaluate the likelihood of triggering liquefaction during an earthquake. Finally, a number of the high quality undisturbed samples were subjected to undrained cyclic testing in order to repeat an earlier (1973) study of the use of cyclic tests data to predict liquefaction behavior at Lower San Fernando Dam.« less
NDI method for quantification of weak bonding strength of composite structures. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R.F.
This Phase 1 Final Report is for a Small Business Innovation Research program conducted for the Navy under Federal Contract N00189-96-M-JT09. The purpose was to investigate ways to determine the overall strength of a composite structure by using a nondestructive evaluative (NDE) optical technique, shearography. The purpose of the research was to determine if there is an effective way to assess the strength of composite components on in-service aircraft rather than in the front end of the composite manufacturing process. The goal was to determine the overall feasibility of such an NDE method, and to investigate various means of probingmore » the material under test.« less
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.
Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa
2017-01-01
Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635
Distal radius geometry and skeletal strength indices after peripubertal artistic gymnastics
Scerpella, T. A.
2011-01-01
Summary Development of optimal skeletal strength should decrease adult bone fragility. Nongymnasts (NON) were compared with girls exposed to gymnastics during growth (EX/GYM), using peripheral quantitative computed tomography (pQCT) to evaluate postmenarcheal bone geometry, density, and strength. Pre- and perimenarcheal gymnastic loading yields advantages in indices of postmenarcheal bone geometry and skeletal strength. Introduction Two prior studies using pQCT have reported bone density and size advantages in Tanner I/II gymnasts, but none describe gymnasts’ bone properties later in adolescence. The current study used pQCT to evaluate whether girls exposed to gymnastics during late childhood growth and perimenarcheal growth exhibited greater indices of distal radius geometry, density, and skeletal strength. Methods Postmenarcheal subjects underwent 4% and 33% distal radius pQCT scans, yielding: 1) vBMD and cross-sectional areas (CSA) (total bone, compartments); 2) polar strength-strain index; 3) index of structural strength in axial compression. Output was compared for EX/GYM vs. NON, adjusting for gynecological age and stature (maturity and body size), reporting means, standard errors, and significance. Results Sixteen postmenarcheal EX/GYM (age 16.7 years; gynecological age 3.4 years) and 13 NON (age 16.2 years; gynecological age 3.6 years) were evaluated. At both diaphysis and metaphysis, EX/GYM exhibited greater CSA and bone strength indices than NON; EX/GYM exhibited 79% larger intramedullary CSA than NON (p<0.05). EX/GYM had significantly higher 4% trabecular vBMD; differences were not detected for 4% total vBMD and 33% cortical vBMD. Conclusions Following pre-/perimenarcheal gymnastic exposure, relative to nongymnasts, postmenarcheal EX/GYM demonstrated greater indices of distal radius geometry and skeletal strength (metaphysis and diaphysis) with greater metaphyseal trabecular vBMD; larger intramedullary cavity size was particularly striking. PMID:20419293
NASA Astrophysics Data System (ADS)
Shibataki, Takuya; Takahashi, Yasuhito; Fujiwara, Koji
2018-04-01
This paper discusses a measurement method for saturation magnetizations of iron core materials using an electromagnet, which can apply an extremely large magnetic field strength to a specimen. It is said that electrical steel sheets are completely saturated at such a large magnetic field strength over about 100 kA/m. The saturation magnetization can be obtained by assuming that the completely saturated specimen shows a linear change of the flux density with the magnetic field strength because the saturation magnetization is constant. In order to accurately evaluate the flux density in the specimen, an air flux between the specimen and a winding of B-coil for detecting the flux density is compensated by utilizing an ideal condition that the incremental permeability of saturated specimen is equal to the permeability of vacuum. An error of magnetic field strength caused by setting a sensor does not affect the measurement accuracy of saturation magnetization. The error is conveniently cancelled because the saturation magnetization is a function of a ratio of the magnetic field strength to its increment. It may be concluded that the saturation magnetization can be easily measured with high accuracy by using the proposed method.
Murakami, H; Yoneyama, T; Nakajima, K; Kobayashi, M
2001-03-23
The objectives of this study were to prepare the lactose granules by various granulation methods using polyethylene glycol 6000 (PEG 6000) as a binder and to evaluate the effects of granulation methods on the compressibility and compactibility of granules in tabletting. Lactose was granulated by seven granulation methods -- four wet granulations including wet massing granulation, wet high-speed mixer granulation, wet fluidized bed granulation and wet tumbling fluidized bed granulation; and three melt granulations including melt high-speed mixer granulation, melt fluidized bed granulation and melt tumbling fluidized bed granulation. The loose density, angle of repose, granule size distribution, mean diameter of granules, and the tensile strength and porosity of tablets were evaluated. The compactibilities of granules were varied by the granulation methods. However, the difference in compactibility of granules could not be explained due to the difference in compressibility, since there was no difference in Heckel plots due to granulation methods. Among their granule properties, the loose density of granules seemed to have a correlation with the tablet strength regardless of the granulation methods.
Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study
Ranganath, V.; Nichani, Ashish Sham
2013-01-01
Purpose The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-є-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10. PMID:23837127
A PFI mill can be used to predict biomechanical pulp strength properties
Gary F. Leatham; Gary C. Myers
1990-01-01
Recently, we showed that a biomechanical pulping process in which aspen chips are pretreated with a white-rot fungus can give energy savings and can increase paper sheet strength. To optimize this process, we need more efficient ways to evaluate the fungal treatments. Here, we examine a method that consists of treating coarse refiner mechanical pulp, refining in a PFI...
Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Takahashi, Kazuhisa
2014-11-01
Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.
Ethical case deliberation on the ward. A comparison of four methods.
Steinkamp, Norbert; Gordijn, Bert
2003-01-01
The objective of this article is to analyse and compare four methods of ethical case deliberation. These include Clinical Pragmatism, The Nijmegen Method of ethical case deliberation, Hermeneutic dialogue, and Socratic dialogue. The origin of each method will be briefly sketched. Furthermore, the methods as well as the related protocols will be presented. Each method will then be evaluated against the background of those situations in which it is being used. The article aims to show that there is not one ideal method of ethical case deliberation, which fits to all possible kinds of moral problems. Rather, as each of the methods highlights a limited number of morally relevant aspects, each method has its strengths and weaknesses as well. These strengths and weaknesses should be evaluated in relation to different types of situations, for instance moral problems in treatment decisions, moral uneasiness and residue, and the like. The suggestion arrived at on the basis of the findings of this paper is a reasonable methodological plurality. This means that a method can be chosen depending on the type of moral problem to be deliberated upon. At the same time it means, that by means of a method, deliberation should be facilitated.
Concentrated autologous plasma protein: a biochemically neutral solder for tissue welding.
Stewart, R B; Bleustein, C B; Petratos, P B; Chin, K C; Poppas, D P; Kung, R T
2001-01-01
Xenographic or allographic serum protein solders used for laser welding may have immunologic and/or pathogenic complications. The objective of these studies was to develop a safe, autologous solder. Five methods of preparing concentrated autologous plasma protein solder (CAPPS) were evaluated. Next, the CAPPS was evaluated via (1) thermal denaturation studies using differential scanning calorimetry, (2) tissue welding studies to characterize both acute and healing properties. The optimal concentration method to produce CAPPS rapidly was a dialysis method using chemical (osmotic) forces. The CAPPS showed similar denaturation profiles to serum albumin (SA) solders. Acutely, CAPPS provided comparable breaking strengths to SA solders. At 7 days, there was no significant difference in breaking strength or histology between 50% human SA solder and CAPPS (using a porcine skin model). These studies demonstrate that the CAPPS system provides acceptable acute and chronic properties for laser welding. Copyright 2001 Wiley-Liss, Inc.
Tabari, Kasra; Hosseinpour, Sepanta; Mohammad-Rahimi, Hossein
2017-01-01
Introduction: In recent years, the use of ceramic base zirconia is considered in dentistry for all ceramic restorations because of its chemical stability, biocompatibility, and good compressive as well as flexural strength. However, due to its chemical stability, there is a challenge with dental bonding. Several studies have been done to improve zirconia bonding but they are not reliable. The purpose of this research is to study the effect of plasma treatment on bonding strength of zirconia. Methods: In this in vitro study, 180 zirconia discs' (thickness was 0.85-0.9 mm) surfaces were processed with plasma of oxygen, argon, air and oxygen-argon combination with 90-10 and 80-20 ratio (n=30 for each group) after being polished by sandblast. Surface modifications were assessed by measuring the contact angle, surface roughness, and topographical evaluations. Cylindrical Panavia f2 resin-cement and Diafill were used for microshear strength bond measurements. The data analysis was performed by SPSS 20.0 software and one-way analysis of variance (ANOVA) and Tukey test as the post hoc. Results: Plasma treatment in all groups significantly reduces contact angle compare with control ( P =0.001). Topographic evaluations revealed coarseness promotion occurred in all plasma treated groups which was significant when compared to control ( P <0.05), except argon plasma treated group that significantly decreased surface roughness ( P <0.05). In all treated groups, microshear bond strength increased, except oxygen treated plasma group which decreased this strength. Air and argon-oxygen combination (both groups) significantly increased microshear bond strength ( P <0.05). Conclusion: According to this research, plasmatic processing with dielectric barrier method in atmospheric pressure can increase zirconia bonding strength.
Delayed Ego Strength Development in Opioid Dependent Adolescents and Young Adults.
Abramoff, Benjamin A; Lange, Hannah L H; Matson, Steven C; Cottrill, Casey B; Bridge, Jeffrey A; Abdel-Rasoul, Mahmoud; Bonny, Andrea E
2015-01-01
Objective. To evaluate ego strengths, in the context of Erikson's framework, among adolescents and young adults diagnosed with opioid dependence as compared to non-drug using youth. Methods. Opioid dependent (n = 51) and non-drug using control (n = 31) youth completed the self-administered Psychosocial Inventory of Ego Strengths (PIES). The PIES assesses development in the framework of Erikson's ego strength stages. Multivariate linear regression modeling assessed the independent association of the primary covariate (opioid dependent versus control) as well as potential confounding variables (e.g., psychiatric comorbidities, intelligence) with total PIES score. Results. Mean total PIES score was significantly lower in opioid dependent youth (231.65 ± 30.39 opioid dependent versus 270.67 ± 30.06 control; p < 0.01). Evaluation of the PIES subscores found significant (p < 0.05) delays in all ego strength areas (hope, will, purpose, competence, fidelity, love, care, and wisdom). When adjusting for potential confounders, opioid dependence remained a significant (p < 0.001) independent predictor of total PIES score. Conclusion. Adolescents with opioid dependence demonstrated significant delays in ego strength development. A treatment approach acknowledging this delay may be needed in the counseling and treatment of adolescents with opioid dependence.
Delayed Ego Strength Development in Opioid Dependent Adolescents and Young Adults
Abramoff, Benjamin A.; Lange, Hannah L. H.; Matson, Steven C.; Cottrill, Casey B.; Bridge, Jeffrey A.; Abdel-Rasoul, Mahmoud; Bonny, Andrea E.
2015-01-01
Objective. To evaluate ego strengths, in the context of Erikson's framework, among adolescents and young adults diagnosed with opioid dependence as compared to non-drug using youth. Methods. Opioid dependent (n = 51) and non-drug using control (n = 31) youth completed the self-administered Psychosocial Inventory of Ego Strengths (PIES). The PIES assesses development in the framework of Erikson's ego strength stages. Multivariate linear regression modeling assessed the independent association of the primary covariate (opioid dependent versus control) as well as potential confounding variables (e.g., psychiatric comorbidities, intelligence) with total PIES score. Results. Mean total PIES score was significantly lower in opioid dependent youth (231.65 ± 30.39 opioid dependent versus 270.67 ± 30.06 control; p < 0.01). Evaluation of the PIES subscores found significant (p < 0.05) delays in all ego strength areas (hope, will, purpose, competence, fidelity, love, care, and wisdom). When adjusting for potential confounders, opioid dependence remained a significant (p < 0.001) independent predictor of total PIES score. Conclusion. Adolescents with opioid dependence demonstrated significant delays in ego strength development. A treatment approach acknowledging this delay may be needed in the counseling and treatment of adolescents with opioid dependence. PMID:26664819
Development and Evaluation of Stitched Sandwich Panels
NASA Technical Reports Server (NTRS)
Stanley, Larry E.; Adams, Daniel O.; Reeder, James R. (Technical Monitor)
2001-01-01
This study explored the feasibility and potential benefits provided by the addition of through-the-thickness reinforcement to sandwich structures. Through-the-thickness stitching is proposed to increase the interlaminar strength and damage tolerance of composite sandwich structures. A low-cost, out-of-autoclave processing method was developed to produce composite sandwich panels with carbon fiber face sheets, a closed-cell foam core, and through-the-thickness Kevlar stitching. The sandwich panels were stitched in a dry preform state, vacuum bagged, and infiltrated using Vacuum Assisted Resin Transfer Molding (VARTM) processing. For comparison purposes, unstitched sandwich panels were produced using the same materials and manufacturing methodology. Test panels were produced initially at the University of Utah and later at NASA Langley Research Center. Four types of mechanical tests were performed: flexural testing, flatwise tensile testing, core shear testing, and edgewise compression testing. Drop-weight impact testing followed by specimen sectioning was performed to characterize the damage resistance of stitched sandwich panels. Compression after impact (CAI) testing was performed to evaluate the damage tolerance of the sandwich panels. Results show significant increases in the flexural stiffness and strength, out-of-plane tensile strength, core shear strength, edgewise compression strength, and compression-after-impact strength of stitched sandwich structures.
Comparing Methods for UAV-Based Autonomous Surveillance
NASA Technical Reports Server (NTRS)
Freed, Michael; Harris, Robert; Shafto, Michael
2004-01-01
We describe an approach to evaluating algorithmic and human performance in directing UAV-based surveillance. Its key elements are a decision-theoretic framework for measuring the utility of a surveillance schedule and an evaluation testbed consisting of 243 scenarios covering a well-defined space of possible missions. We apply this approach to two example UAV-based surveillance methods, a TSP-based algorithm and a human-directed approach, then compare them to identify general strengths, and weaknesses of each method.
A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance.
Berman, A T; Parks, B G
1990-01-01
The mechanical properties of five synthetic fiberglass casting materials were evaluated and compared with the properties of plaster of Paris. Two of the tests were designed to bear clinical relevance and the third to determine intrinsic material properties. The effect of water on strength degradation was also evaluated. It was found that the synthetics as a group are far superior to plaster of Paris in all methods of testing and that, among the synthetics, KCast Tack Free, Deltalite "S", and KCast Improved were the stronger materials. Clinically, the most important results are that the synthetics attain their relatively high strength in a much shorter time frame than does plaster of Paris, and retain 70-90% of their strength after being immersed in water and allowed to dry.
BIOMECHANICAL DIFFERENCES IN BRAZILIAN JIU-JITSU ATHLETES: THE ROLE OF COMBAT STYLE
Lima, Alane Almeida; Coelho, Anita Camila Sampaio; Lima, Yuri Lopes; Almeida, Gabriel Peixoto Leão; Bezerra, Márcio Almeida; de Oliveira, Rodrigo Ribeiro
2017-01-01
Background Brazilian Jiu-Jitsu (BJJ) athletes can be divided into two combat styles: pass fighters (PFs) and guard fighters (GFs). Flexibility of the posterior chain muscles is highly necessary in these athletes, especially in GFs. On the other hand, isometric strength of the trunk extensors is required in PFs. Handgrip strength is important in holding the kimono of the opponent, and symmetrical lower-limb strength is important for the prevention of injuries due to the overload caused by training. Purpose The aim of this study was to compare the biomechanical profiles of BJJ athletes with different combat styles using the following outcome measures: flexibility, trunk extensor isometric endurance, postural balance, handgrip isometric endurance and lower-limb muscle strength. Methods A cross-sectional study was conducted using 19 GFs and 19 PFs. The sit-and-reach test was used to evaluate the flexibility of the posterior chain muscles. The Biodex Balance System® was used to evaluate balance. A handgrip dynamometer and a dorsal dynamometer were used to evaluate handgrip and trunk extensor endurance, respectively. Quadriceps and hamstring strength were evaluated with an isokinetic dynamometer at 60 °/s. Results No differences were observed between groups in terms of flexibility, balance, handgrip isometric endurance or quadriceps and hamstring strength; however, PFs (81.33) showed more isometric trunk extension endurance than GFs (68.85) (p = 0.02). Both groups had low values for hamstring/quadriceps ratio. Conclusion No significant biomechanical differences were observed between PFs and GFs. Level of Evidence 2b PMID:28217417
Toodehzaeim, Mohammad Hossein; Zandi, Hengameh; Meshkani, Hamidreza; Hosseinzadeh Firouzabadi, Azadeh
2018-01-01
Statement of the Problem: Orthodontic appliances facilitate microbial plaque accumulation and increase the chance of white spot lesions. There is a need for new plaque control methods independent of patient's cooperation. Purpose: The aim of this study was to determine the effects of incorporating copper oxide (CuO) nanoparticles on antimicrobial properties and bond strength of orthodontic adhesive. Materials and Method: CuO nanoparticles were added to the composite transbond XT at concentrations of 0.01, 0.5 and 1 wt.%. To evaluate the antimicrobial properties of composites containing nanoparticles, the disk agar diffusion test was used. For this purpose, 10 discs from each concentration of nano-composites (totally 30 discs) and 10 discs from conventional composite (as the control group) were prepared. Then the diameter of streptococcus mutans growth inhibition around each disc was determined in blood agar medium. To evaluate the shear bond strength, with each concentration of nano-composites as well as the control group (conventional composite), 10 metal brackets were bonded to the human premolars and shear bond strength was determined using a universal testing machine. Results: Nano-composites in all three concentrations showed significant antimicrobial effect compared to the control group (p< 0.001). With increasing concentration of nanoparticles, antimicrobial effect showed an upward trend, although statistically was not significant. There was no significant difference between the shear bond strength of nano-composites compared to control group (p= 0.695). Conclusion: Incorporating CuO nanoparticles into adhesive in all three studied concentrations added antimicrobial effects to the adhesive with no adverse effects on shear bond strength. PMID:29492409
Study of the Peak Shear Strength of a Cement-Filled Hard Rock Joint
NASA Astrophysics Data System (ADS)
She, Cheng-Xue; Sun, Fu-Ting
2018-03-01
The peak shear strength of a cement-filled hard rock joint is studied by theoretical analysis and laboratory testing. Based on the concept of the shear resistance angle, by combining the statistical method and fractal theory, three new parameters are proposed to characterize the three-dimensional joint morphology, reflecting the effects of the average roughness, multi-scale asperities and the dispersion degree of the roughness distribution. These factors are independent of the measurement scale, and they reflect the anisotropy of the joint roughness. Compressive shear tests are conducted on cement-filled joints. Because joints without cement can be considered special cement-filled joints in which the filling degree of cement is zero, they are also tested. The cement-filled granite joint fails primarily along the granite-cement interfaces. The filling degree of cement controls the joint failure and affects its mechanical behaviour. With a decrease in the filling degree of cement, the joint cohesion decreases; however, the dilatancy angle and the basic friction angle of the interface increase. As the filling degree approaches zero, the cohesion approaches zero, while the dilatancy angle and the basic friction angle increase to those of the joint without cement. A set of formulas is proposed to evaluate the peak shear strength of the joints with and without cement. The formulas are shown to be reasonable by comparison with the tested peak shear strength, and they reflect the anisotropy of the strength. This research deepens the understanding of cement-filled joints and provides a method to evaluate their peak shear strength.
An acoustic method for predicting relative strengths of cohesive sediment deposits
NASA Astrophysics Data System (ADS)
Reed, A. H.; Sanders, W. M.
2017-12-01
Cohesive sediment dynamics are fundamentally determined by sediment mineralogy, organic matter composition, ionic strength of water, and currents. These factors work to bind the cohesive sediments and to determine depositional rates. Once deposited the sediments exhibit a nonlinear response to stress and they develop increases in shear strength. Shear strength is critically important in resuspension, transport, creep, and failure predictions. Typically, shear strength is determined by point measurements, both indirectly from free-fall penetrometers or directly on cores with a shear vane. These values are then used to interpolate over larger areas. However, the remote determination of these properties would provide continuos coverage, yet it has proven difficult with sonar systems. Recently, findings from an acoustic study on cohesive sediments in a laboratory setting suggests that cohesive sediments may be differentiated using parametric acoustics; this method pulses two primary frequencies into the sediment and the resultant difference frequency is used to determine the degree of acoustic nonlinearity within the sediment. In this study, two marine clay species, kaolinite and montmorillonite, and two biopolymers, guar gum and xanthan gum were mixed to make nine different samples. The samples were evaluated in a parametric acoustic measurement tank. From the parametric acoustic measurements, the quadratic nonlinearity coefficient (beta) was determined. beta was correlated with the cation exchange capacity (CEC), an indicator of shear strength. The results indicate that increased acoustic nonlinearity correlates with increased CEC. From this work, laboratory measurements indicate that this correlation may be used evaluate geotechnical properties of cohesive sediments and may provide a means to predict sediment weakness in subaqueous environments.
NASA Astrophysics Data System (ADS)
Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan
2012-01-01
Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.
Evaluation and prediction of long-term environmental effects of nonmetallic materials
NASA Technical Reports Server (NTRS)
Papazian, H.
1985-01-01
The properties of a number of nonmetallic materials were evaluated experimentally in simulated space environments in order to develop models for accelerated test methods useful for predicting such behavioral changes. Graphite-epoxy composites were exposed to thermal cycling. Adhesive foam tapes were subjected to a vacuum environment. Metal-matrix composites were tested for baseline data. Predictive modeling designed to include strength and aging effects on composites, polymeric films, and metals under such space conditions (including the atomic oxygen environment) is discussed. The Korel 8031-00 high strength adhesive foam tape was shown to be superior to the other two tested.
Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi
2016-01-01
[Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were evaluated at the beginning of the study and after 12 weeks. Abdominal ultrasonography measurements in transverse and longitudinal planes, the PERFECT scheme, perineometric evaluation, the stop test, the stress test, and the pad test were used to assess pelvic floor muscle strength in all cases. [Results] After training, the PERFECT, perineometry and transabdominal ultrasonography measurements were found to be significantly improved, and the stop test and pad test results were significantly decreased in the pelvic floor muscle training group, whereas no difference was observed in the control group. There was a positive correlation between the PERFECT force measurement scale and ultrasonography force measurement scale before and after the intervention in the control and pelvic floor muscle training groups (r=0.632 and r=0.642, respectively). [Conclusion] Ultrasonography can be used as a noninvasive method to identify the change in pelvic floor muscle strength with exercise training. PMID:27065519
Yoosefinejad, Amin Kordi; Ghaffarinejad, Farahnaz; Hemati, Mahbubeh; Jamshidi, Narges
2018-05-21
Hyperkyphosis is a common postural defect with high prevalence in the 20 to 50 year old population. It appears to compromise proximal scapular stability. Grip and pinch strength are used to evaluate general upper extremity function. The aim of this study was to compare pinch and grip strength between young women with and without hyperkyphosis. Thirty young women (18-40 years old) with hyperkyphosis and 30 healthy women matched for age and body mass index participated in the study. Hyperkyphosis was confirmed by measuring the kyphosis angle with a flexible ruler. Grip strength was measured with the Waisa method and a dynamometer. Pinch strength was assessed with a pinch meter. Grip (P= 0.03) and pinch strength (P= 0.04) were significantly lower in women with hyperkyphosis compared to the control group. Kyphosis angle correlated weakly with grip (r= 0.26) and pinch strength (r= 0.23). Hyperkyphotic posture has led to decreased grip and pinch strength compared to people without hyperkyphosis.
Koodaryan, Roodabeh; Hafezeqoran, Ali
2016-12-01
Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (α=.05). The bond strength values of A and S were significantly higher than those of N ( P <.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG ( P <.001). The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.
Differences in maximal strength and endurance of the tongue according to region in healthy adults
Oh, Dong-Hwan; Park, Ji-Su; Kim, Won-Jin
2017-01-01
[Purpose] The purpose of this study was to identify differences in maximal strength and endurance of the tongue among healthy adults. [Subjects and Methods] A total of 60 healthy volunteers (30 men; 30 women; age range, 20–26 years) were recruited and evaluated for maximal strength and endurance of the anterior and posterior regions of the tongue using the Iowa Oral Performance Instrument. [Results] Tongue strength in the anterior region was greater than that in the posterior region. In contrast, tongue endurance in the posterior region was greater than that in the anterior region. [Conclusion] In conclusion, these results confirm that the anterior region of the tongue exhibits greater strength, whereas the posterior region exhibits greater endurance. PMID:29184299
Effect of surface treatments on the bond strengths of facing composite resins to zirconia copings.
Tsumita, M; Kokubo, Y; Kano, T
2012-09-01
The present study evaluated and compared the bond strength between zirconia and facing composite resin using different surface conditioning methods before and after thermocycling. Four primers, three opaque resins, and two facing composite resins were used, and 10 surface treatment procedures were conducted. The bond strength was measured before and after 4,000 cycles of thermocycling. The mean values of each group were statistically analyzed using one-way analysis of variance (ANOVA). The bond strengths of facing composite resins to zirconia after various treatments varied depending on the primers, opaque resins, body resins, and thermocycling. The application of primers and opaque resins to the zirconia surface after sandblasting is expected to yield strong bond strength of the facing composite resin (Estenia CG&B) even after thermocycling.
Kim, Moon-Hwan; Oh, Jae-Seop
2015-01-01
[Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.
NASA Astrophysics Data System (ADS)
Simiele, E.; Kapsch, R.-P.; Ankerhold, U.; Culberson, W.; DeWerd, L.
2018-04-01
The purpose of this work was to characterize intensity and spectral response changes in a plastic scintillation detector (PSD) as a function of magnetic field strength. Spectra measurements as a function of magnetic field strength were performed using an optical spectrometer. The response of both a PSD and PMMA fiber were investigated to isolate the changes in response from the scintillator and the noise signal as a function of magnetic field strength. All irradiations were performed in water at a photon beam energy of 6 MV. Magnetic field strengths of (0, ±0.35, ±0.70, ±1.05, and ±1.40) T were investigated. Four noise subtraction techniques were investigated to evaluate the impact on the resulting noise-subtracted scintillator response with magnetic field strength. The noise subtraction methods included direct spectral subtraction, the spectral method, and variants thereof. The PMMA fiber exhibited changes in response of up to 50% with magnetic field strength due to the directional light emission from \\breve{C} erenkov radiation. The PSD showed increases in response of up to 10% when not corrected for the noise signal, which agrees with previous investigations of scintillator response in magnetic fields. Decreases in the \\breve{C} erenkov light ratio with negative field strength were observed with a maximum change at ‑1.40 T of 3.2% compared to 0 T. The change in the noise-subtracted PSD response as a function of magnetic field strength varied with the noise subtraction technique used. Even after noise subtraction, the PSD exhibited changes in response of up to 5.5% over the four noise subtraction methods investigated.
Composite bonding to stainless steel crowns using a new universal bonding and single-bottle systems.
Hattan, Mohammad Ali; Pani, Sharat Chandra; Alomari, Mohammad
2013-01-01
Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80) stainless steel crowns (SSCs) were divided into four groups (20 each). Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group), Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany), and Group C and Group D using two different brands of single-bottle adhesive systems. Shear bond strengths were calculated and the types of failure also were recorded. Results. The shear strength of Group B was significantly greater than that of other groups. No significant differences were found between the shear bond strengths of Groups C and D. The control group had significantly lower shear bond strength (P < 0.05) to composite than the groups that utilized bonding agents. Conclusion. Composites bonding to stainless steel crowns using the new universal bonding agent (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany) show significantly greater shear bond strengths and fewer adhesive failures when compared to traditional single-bottle systems.
Simplified Design Method for Tension Fasteners
NASA Astrophysics Data System (ADS)
Olmstead, Jim; Barker, Paul; Vandersluis, Jonathan
2012-07-01
Tension fastened joints design has traditionally been an iterative tradeoff between separation and strength requirements. This paper presents equations for the maximum external load that a fastened joint can support and the optimal preload to achieve this load. The equations, based on linear joint theory, account for separation and strength safety factors and variations in joint geometry, materials, preload, load-plane factor and thermal loading. The strength-normalized versions of the equations are applicable to any fastener and can be plotted to create a "Fastener Design Space", FDS. Any combination of preload and tension that falls within the FDS represents a safe joint design. The equation for the FDS apex represents the optimal preload and load capacity of a set of joints. The method can be used for preliminary design or to evaluate multiple pre-existing joints.
Mechanical response tissue analyzer for estimating bone strength
NASA Technical Reports Server (NTRS)
Arnaud, Sara B.; Steele, Charles; Mauriello, Anthony
1991-01-01
One of the major concerns for extended space flight is weakness of the long bones of the legs, composed primarily of cortical bone, that functions to provide mechanical support. The strength of cortical bone is due to its complex structure, described simplistically as cylinders of parallel osteons composed of layers of mineralized collagen. The reduced mechanical stresses during space flight or immobilization of bone on Earth reduces the mineral content, and changes the components of its matrix and structure so that its strength is reduced. Currently, the established clinical measures of bone strength are indirect. The measures are based on determinations of mineral density by means of radiography, photon absorptiometry, and quantitative computer tomography. While the mineral content of bone is essential to its strength, there is growing awareness of the limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially osteoporosis. Other experimental methods in clinical trials that more directly evaluate the physical properties of bone, and do not require exposure to radiation, include ultrasound, acoustic emission, and low-frequency mechanical vibration. The last method can be considered a direct measure of the functional capacity of a long bone since it quantifies the mechanical response to a stimulus delivered directly to the bone. A low frequency vibration induces a response (impedance) curve with a minimum at the resonant frequency, that a few investigators use for the evaluation of the bone. An alternative approach, the method under consideration, is to use the response curve as the basis for determination of the bone bending stiffness EI (E is the intrinsic material property and I is the cross-sectional moment of inertia) and mass, fundamental mechanical properties of bone.
Muzíková, J; Hájková, P; Vinklarová, S
2004-07-01
The paper studied the strength of compacts of dry binders consisting of powdered cellulose and directly compressible lactose. The powdered cellulose employed was Arbocel A300, the directly compressible lactose, Pharmatosa DCL 21. The first step of the evaluation comprised the tensile strength of compacts and sensitivity of dry binders alone to an addition of magnesium stearate. The same method of evaluation was then used for mixed dry binders from Arbocel A300 and Pharmatosa DCL 21 in ratios of 3:1, 1:1 and 1:3. The tested concentrations of magnesium stearate were 0.4 and 0.8%. Sensitivity of dry binders to an addition of the lubricant was evaluated by means of lubricant sensitivity ratio (LSR) values. The compacts with the highest strength and at the same time the lowest sensitivity to an addition of magnesium stearate were produced using a mixture of Arbocel A300 and Pharmatosa DCL 21 in a ratio of 1:3. The evaluation also included the commercially produced mixed dry binder Cellactosa 80, in which higher sensitivity to an addition of stearate than in a mixture of Arbocel A300 and Pharmatosa DCL 21 in a ratio of 1:3 was found.
Parallel algorithms for simulating continuous time Markov chains
NASA Technical Reports Server (NTRS)
Nicol, David M.; Heidelberger, Philip
1992-01-01
We have previously shown that the mathematical technique of uniformization can serve as the basis of synchronization for the parallel simulation of continuous-time Markov chains. This paper reviews the basic method and compares five different methods based on uniformization, evaluating their strengths and weaknesses as a function of problem characteristics. The methods vary in their use of optimism, logical aggregation, communication management, and adaptivity. Performance evaluation is conducted on the Intel Touchstone Delta multiprocessor, using up to 256 processors.
Student Perspectives: Evaluating a Higher Education Administration Program
ERIC Educational Resources Information Center
Roberts, Jalynn; Gentry, Debra; Townsend, Amy
2011-01-01
The purpose of this mixed-method study was to evaluate a Higher Education Administration doctoral program, to understand student perceptions of program quality, to improve both student satisfaction and retention to degree completion, and to plan for the future. Findings from survey data and focus group interviews indicated program strengths to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. A. Smith; D. L. Cottle; B. H. Rabin
2013-09-01
This report summarizes work conducted to-date on the implementation of new laser-based capabilities for characterization of bond strength in nuclear fuel plates, and presents preliminary results obtained from fresh fuel studies on as-fabricated monolithic fuel consisting of uranium-10 wt.% molybdenum alloys clad in 6061 aluminum by hot isostatic pressing. Characterization involves application of two complementary experimental methods, laser-shock testing and laser-ultrasonic imaging, collectively referred to as the Laser Shockwave Technique (LST), that allows the integrity, physical properties and interfacial bond strength in fuel plates to be evaluated. Example characterization results are provided, including measurement of layer thicknesses, elastic properties ofmore » the constituents, and the location and nature of generated debonds (including kissing bonds). LST provides spatially localized, non-contacting measurements with minimum specimen preparation, and is ideally suited for applications involving radioactive materials, including irradiated materials. The theoretical principles and experimental approaches employed in characterizing nuclear fuel plates are described, and preliminary bond strength measurement results are discussed, with emphasis on demonstrating the capabilities and limitations of these methods. These preliminary results demonstrate the ability to distinguish bond strength variations between different fuel plates. Although additional development work is necessary to validate and qualify the test methods, these results suggest LST is viable as a method to meet fuel qualification requirements to demonstrate acceptable bonding integrity.« less
ETV Program Report: Coatings for Wastewater Collection ...
The Standard Cement Materials, Inc. Standard Epoxy Coating 4553™ (SEC 4553) epoxy coating used for wastewater collection system rehabilitation was evaluated by EPA’s Environmental Technology Verification Program under laboratory conditions at the Center for Innovative Grouting Material and Technology (CIGMAT) Laboratory at the University of Houston. Testing was conducted over a period of six months to evaluate the coating’s (1) chemical resistance and (2) bonding strength for infrastructure applications. For chemical resistance, coated concrete and clay bricks with holidays (holes created in the coating) were used to evaluate the chemical resistance of the coating/substrate bond under a corrosive environment. Twenty coated concrete (dry and wet) and 20 coated clay brick (dry and wet) specimens were exposed to DI water and sulfuric acid solution (pH=1), and the specimens were visually inspected and weight changes measured. Evaluation of the coating-to-substrate bonding strength was determined using two modified ASTM test methods – one to determine bond strength of the coating with two specimens sandwiched together using the coating, and the second to determine the bond strength by applying a tensile load to the coating applied to specimens of each substrate. Forty-eight bonding tests were performed over the six month evaluation. The tests resulted in the following conclusions about Standard Cement’s SEC 4553 coating: • After the six-month chemi
Free-form reticulated shell structures searched for maximum buckling strength
NASA Astrophysics Data System (ADS)
Takiuchi, Yuji; Kato, Shiro; Nakazawa, Shoji
2017-10-01
In this paper, a scheme of shape optimization is proposed for maximum buckling strength of free-form steel reticulated shells. In order to discuss the effectiveness of objective functions with respect to maximizing buckling strength, several different optimizations are applied to shallow steel single layer reticulated shells targeting rigidly jointed tubular members. The objective functions to be compared are linear buckling load, strain energy, initial yield load, and elasto-plastic buckling strength evaluated based on Modified Dunkerley Formula. With respect to obtained free-forms based on the four optimization schemes, both of their elastic buckling and elasto-plastic buckling behaviour are investigated and compared considering geometrical imperfections. As a result, it is concluded that the first and fourth optimization methods are effective from a viewpoint of buckling strength. And the relation between generalized slenderness ratio and appropriate objective function applied in buckling strength maximization is made clear.
NASA Astrophysics Data System (ADS)
Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti
2017-12-01
This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.
Cho, S D; Rajitrangson, P; Matis, B A; Platt, J A
2013-01-01
Aged resin composites have a limited number of carbon-carbon double bonds to adhere to a new layer of resin. Study objectives were to 1) evaluate various surface treatments on repaired shear bond strength between aged and new resin composites and 2) to assess the influence of a silane coupling agent after surface treatments. Eighty disk-shape resin composite specimens were fabricated and thermocycled 5000 times prior to surface treatment. Specimens were randomly assigned to one of the three surface treatment groups (n=20): 1) air abrasion with 50-μm aluminum oxide, 2) tribochemical silica coating (CoJet), or 3) Er,Cr:YSGG (erbium, chromium: yttrium-scandium-gallium-garnet) laser or to a no-treatment control group (n=20). Specimens were etched with 35% phosphoric acid, rinsed, and dried. Each group was divided into two subgroups (n=10): A) no silanization and B) with silanization. The adhesive agent was applied and new resin composite was bonded to each conditioned surface. Shear bond strength was evaluated and data analyzed using two-way analysis of variance (ANOVA). Air abrasion with 50-μm aluminum oxide showed significantly higher repair bond strength than the Er,Cr:YSGG laser and control groups. Air abrasion with 50-μm aluminum oxide was not significantly different from tribochemical silica coating. Tribochemical silica coating had significantly higher repair bond strength than Er,Cr:YSGG laser and the control. Er,Cr:YSGG laser and the control did not have significantly different repair bond strengths. Silanization had no influence on repair bond strength for any of the surface treatment methods. Air abrasion with 50-μm aluminum oxide and tribochemical silica followed by the application of bonding agent provided the highest repair shear bond strength values, suggesting that they might be adequate methods to improve the quality of repairs of resin composites.
Measures of Muscular Strength in U.S. Children and Adolescents, 2012
... errors of the percentages were estimated using Taylor series linearization, a method that incorporates the sample weights and sample design. Differences between groups were evaluated using a t ...
Dundar, Mine; Gungor, Mehmet Ali; Cal, Ebru; Darcan, Alev; Erdem, Adalet
2007-01-01
Because adherence of base metal alloys is important for the long-term clinical success of adhesive fixed partial dentures, it has been necessary to improve adhesion to metal substrate by using different surface treatments. This study used different surface conditioning methods and two different luting resins to evaluate the shear bond strength of base metal alloys to dentin and enamel. Sixty noncarious freshly extracted human teeth were mounted in a plastic holder filled with autopolymerized acrylic resin. After the roots were removed and 30 flat enamel and 30 flat dentin surfaces were exposed, the specimens were divided randomly into two main luting cement groups. Sixty nickel chromium (NiCr) metal specimens were fabricated and subjected to three different surface conditioning procedures: sandblasting with 50 microm aluminum oxide, tribochemical silica coating, and a combination of the two. Scanning electron mircoscopy (SEM) evaluations revealed mainly cohesive failures. Self-cure adhesive resulted in higher bond strengths to dental substrates. Higher bond strengths were achieved through a combination of sandblasting and tribochemical silica coating; however, further clinical research is required. A surface treatment that combines sandblasting with tribochemical silica coating can achieve a more effective bond for adhesive restorations with metal substrates.
Adhesive and Cohesive Strength in FeB/Fe2B Systems
NASA Astrophysics Data System (ADS)
Meneses-Amador, A.; Blancas-Pérez, D.; Corpus-Mejía, R.; Rodríguez-Castro, G. A.; Martínez-Trinidad, J.; Jiménez-Tinoco, L. F.
2018-05-01
In this work, FeB/Fe2B systems were evaluated by the scratch test. The powder-pack boriding process was performed on the surface of AISI M2 steel. The mechanical parameters, such as yield stress and Young's modulus of the boride layer, were obtained by the instrumented indentation technique. Residual stresses produced on the boride layer were estimated by using the x-ray diffraction (XRD) technique. The scratch test was performed in order to evaluate the cohesive/adhesive strength of the FeB/Fe2B coating. In addition, a numerical evaluation of the scratch test on boride layers was performed by the finite element method. Maximum principal stresses were related to the failure mechanisms observed by the experimental scratch test. Shear stresses at the interfaces of the FeB/Fe2B/substrate system were also evaluated. Finally, the results obtained provide essential information about the effect of the layer thickness, the residual stresses, and the resilience modulus on the cohesive/adhesive strength in FeB/Fe2B systems.
Reconstruction of the first web space in symbrachydactyly using the reverse radial forearm flap.
Gülgönen, Ayan; Güdemez, Eftal
2007-02-01
To present a new approach for the reconstruction of severe first web contractures using a distally based reverse radial forearm flap in symbrachydactyly patients. This study included 6 hands in 5 patients. Subjective evaluation included appearance, parent satisfaction (and patient satisfaction when appropriate), and ability to perform daily activities such as thumb-index grasp and pinch at follow-up evaluations. We measured the angle between the first and second rays using a goniometer at maximum radial abduction, and pinch and grasp strengths were evaluated as an objective assessment. The average follow-up period was 2 years. All parents and patients were happy with the aesthetic appearance. They were completely satisfied in their daily living activities. The average first web angle measurement was 56 degrees . An average of 39 degrees of improvement of web measurement was achieved. For the unilateral 4 patients, the average pinch strength measurement was 80% of the normal contralateral hand and the grip strength was 75% of the normal contralateral hand. The reverse radial forearm flap was found to be a safe and simple method in the reconstruction of severe first web contractures in symbrachydactyly patients. This method provided good coverage of appropriate thickness and skin quality, and supple soft tissue that filled the first web space. Therapeutic IV.
Cui, Dong; Pu, Weiting; Liu, Jing; Bian, Zhijie; Li, Qiuli; Wang, Lei; Gu, Guanghua
2016-10-01
Synchronization is an important mechanism for understanding information processing in normal or abnormal brains. In this paper, we propose a new method called normalized weighted-permutation mutual information (NWPMI) for double variable signal synchronization analysis and combine NWPMI with S-estimator measure to generate a new method named S-estimator based normalized weighted-permutation mutual information (SNWPMI) for analyzing multi-channel electroencephalographic (EEG) synchronization strength. The performances including the effects of time delay, embedding dimension, coupling coefficients, signal to noise ratios (SNRs) and data length of the NWPMI are evaluated by using Coupled Henon mapping model. The results show that the NWPMI is superior in describing the synchronization compared with the normalized permutation mutual information (NPMI). Furthermore, the proposed SNWPMI method is applied to analyze scalp EEG data from 26 amnestic mild cognitive impairment (aMCI) subjects and 20 age-matched controls with normal cognitive function, who both suffer from type 2 diabetes mellitus (T2DM). The proposed methods NWPMI and SNWPMI are suggested to be an effective index to estimate the synchronization strength. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tanış, Merve Çakırbay; Akçaboy, Cihan
2015-01-01
Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group III surface microcracks connecting each other were observed. Tribochemical silica coating is an effective method for achieving an acceptable bond between zirconia and resin cement. Use of a MDP monomer containing resin cement increases the bond strength of sandblasted zirconia.
NASA Astrophysics Data System (ADS)
Dabiri, M.; Ghafouri, M.; Rohani Raftar, H. R.; Björk, T.
2018-03-01
Methods to estimate the strain-life curve, which were divided into three categories: simple approximations, artificial neural network-based approaches and continuum damage mechanics models, were examined, and their accuracy was assessed in strain-life evaluation of a direct-quenched high-strength steel. All the prediction methods claim to be able to perform low-cycle fatigue analysis using available or easily obtainable material properties, thus eliminating the need for costly and time-consuming fatigue tests. Simple approximations were able to estimate the strain-life curve with satisfactory accuracy using only monotonic properties. The tested neural network-based model, although yielding acceptable results for the material in question, was found to be overly sensitive to the data sets used for training and showed an inconsistency in estimation of the fatigue life and fatigue properties. The studied continuum damage-based model was able to produce a curve detecting early stages of crack initiation. This model requires more experimental data for calibration than approaches using simple approximations. As a result of the different theories underlying the analyzed methods, the different approaches have different strengths and weaknesses. However, it was found that the group of parametric equations categorized as simple approximations are the easiest for practical use, with their applicability having already been verified for a broad range of materials.
Zani, Fabiana Vieira Breijão; Aguilar-Nascimento, José Eduardo; Nascimento, Diana Borges Dock; da Silva, Ageo Mário Cândido; Caporossi, Fernanda Stephan; Caporossi, Cervantes
2015-01-01
ABSTRACT Objective: To evaluate the change in respiratory function and functional capacity according to the type of preoperative fasting. Methods: Randomized prospective clinical trial, with 92 female patients undergoing cholecystectomy by laparotomy with conventional or 2 hours shortened fasting. The variables measured were the peak expiratory flow, forced expiratory volume in the first second, forced vital capacity, dominant handgrip strength, and non-dominant handgrip strength. Evaluations were performed 2 hours before induction of anesthesia and 24 hours after the operation. Results: The two groups were similar in preoperative evaluations regarding demographic and clinical characteristics, as well as for all variables. However, postoperatively the group with shortened fasting had higher values than the group with conventional fasting for lung function tests peak expiratory flow (128.7±62.5 versus 115.7±59.9; p=0.040), forced expiratory volume in the first second (1.5±0.6 versus 1.2±0.5; p=0.040), forced vital capacity (2.3±1.1 versus 1.8±0.9; p=0.021), and for muscle function tests dominant handgrip strength (24.9±6.8 versus 18.4±7.7; p=0.001) and non-dominant handgrip strength (22.9±6.3 versus 17.0±7.8; p=0.0002). In the intragroup evaluation, there was a decrease in preoperative compared with postoperative values, except for dominant handgrip strength (25.2±6.7 versus 24.9±6.8; p=0.692), in the shortened fasting group. Conclusion: Abbreviation of preoperative fasting time with ingestion of maltodextrin solution is beneficial to pulmonary function and preserves dominant handgrip strength. PMID:26154547
Patil, Suneel G; Sajjan, MC Suresh; Patil, Rekha
2015-01-01
Background: The luting cements must withstand masticatory and parafunctional stresses in the warm and wet oral environment. Mouth temperature and the temperature of the ingested foods may induce thermal variation and plastic deformation within the cements and might affect the strength properties. The objectives of this study were to evaluate the effect of temperature on the compressive and diametral tensile strengths of two polycarboxylate, a conventional glass ionomer and a resin modified glass ionomer luting cements and, to compare the compressive strength and the diametral tensile strength of the selected luting cements at varying temperatures. Materials and Methods: In this study, standardized specimens were prepared. The temperature of the specimens was regulated prior to testing them using a universal testing machine at a crosshead speed of 1 mm/min. Six specimens each were tested at 23°C, 37°C and 50°C for both the compressive and diametral tensile strengths, for all the luting cements. Results: All the luting cements showed a marginal reduction in their compressive and diametral tensile strengths at raised temperatures. Fuji Plus was strongest in compression, followed by Fuji I > Poly F > Liv Carbo. Fuji Plus had the highest diametral tensile strength values, followed by Poly F = Fuji I = Liv Carbo, at all temperatures. Conclusion: An increase in the temperature caused no significant reduction in the compressive and diametral tensile strengths of the cements evaluated. The compressive strength of the luting cements differed significantly from one another at all temperatures. The diametral tensile strength of resin modified glass ionomers differed considerably from the other cements, whereas there was no significant difference between the other cements, at all the temperatures. PMID:25859100
Klosa, Karsten; Wolfart, Stefan; Lehmann, Frank; Wenz, Hans-Jürgen; Kern, Matthias
2009-04-01
The purpose of this in-vitro study was to evaluate the resin bond strength to pre-etched lithium disilicate ceramic using different cleaning methods after two contamination modes (saliva or saliva and silicone). Plexiglas tubes filled with composite resin (MultiCore Flow) were bonded to etched and silanized ceramic disks made of lithium disilicate ceramic (IPS e.max Press) using a luting resin (Multilink Automix). Either etched or unetched ceramic surfaces were contaminated with saliva or with saliva followed by a disclosing silicone. Groups of 16 specimens each were bonded after pretreatment using 4 surface cleaning agents (37% phosphoric acid, 5% hydrofluoric acid, 96% isopropanol, air polishing device with sodium bicarbonate) in different combinations. Before measuring tensile bond strength, specimens were stored for 3 or 150 days with thermocycling. After 150 days of storage, etching of saliva-contaminated surfaces with 5% hydrofluoric acid and/or 37% phosphoric acid provided statistically significantly higher bond strengths (37.9 to 49.5 MPa) than the other cleaning methods (1.7 to 15.5 MPa). After saliva and silicone contamination, etching with 5% hydrofluoric acid provided statistically significantly higher bond strengths (44.5 to 50.3 MPa) than all other cleaning methods (0.3 to 13.5 MPa). Ceramic cleaning methods after try-in procedures have a significant influence on the resin bond strength and are dependent on the type of contamination. Re-etching lithium disilicate ceramic with 5% hydrofluoric acid is most effective in removing contamination with saliva and/or a silicone disclosing medium.
Push-off tests and strength evaluation of joints combining shrink fitting with bonding
NASA Astrophysics Data System (ADS)
Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi
1997-03-01
Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.
Martinho, Natalia M.; Silva, Valéria R.; Marques, Joseane; Carvalho, Leonardo C.; Iunes, Denise H.; Botelho, Simone
2016-01-01
ABSTRACT Objective To evaluate the effectiveness of abdominopelvic training by virtual reality compared to pelvic floor muscle training (PFMT) using a gym ball (a previously tested and efficient protocol) on postmenopausal women’s pelvic floor muscle (PFM) strength. Method A randomized controlled trial was conducted with 60 postmenopausal women, randomly allocated into two groups: Abdominopelvic training by virtual reality – APT_VR (n=30) and PFMT using a gym ball – PFMT_GB (n=30). Both types of training were supervised by the same physical therapist, during 10 sessions each, for 30 minutes. The participants’ PFM strength was evaluated by digital palpation and vaginal dynamometry, considering three different parameters: maximum strength, average strength and endurance. An intention-to-treat approach was used to analyze the participants according to original groups. Results No significant between-group differences were observed in most analyzed parameters. The outcome endurance was higher in the APT_VR group (p=0.003; effect size=0.89; mean difference=1.37; 95% CI=0.46 to 2.28). Conclusion Both protocols have improved the overall PFM strength, suggesting that both are equally beneficial and can be used in clinical practice. Muscle endurance was higher in patients who trained using virtual reality. PMID:27437716
A process-oriented measure of habit strength for moderate-to-vigorous physical activity
Grove, J. Robert; Zillich, Irja; Medic, Nikola
2014-01-01
Purpose: Habitual action is an important aspect of health behaviour, but the relevance of various habit strength indicators continues to be debated. This study focused specifically on moderate-to-vigorous physical activity (MVPA) and evaluated the construct validity of a framework emphasizing patterned action, stimulus-response bonding, automaticity, and negative consequences for nonperformance as indicators of habit strength for this form of exercise. Methods: Upper-level undergraduates (N = 124) provided demographic information and responded to questionnaire items assessing historical MVPA involvement, current MVPA involvement, and the four proposed habit strength dimensions. Factor analyses were used to examine the latent structure of the habit strength indicators, and the model's construct validity was evaluated via an examination of relationships with repetition history and current behaviour. Results: At a measurement level, findings indicated that the proposed four-component model possessed psychometric integrity as a coherent set of factors. Criterion-related validity was also demonstrated via significant changes in three of the four factors as a function of past involvement in MVPA and significant correlations with the frequency, duration, and intensity of current MVPA. Conclusions: These findings support the construct validity of this exercise habit strength model and suggest that it could provide a template for future research on how MVPA habits are developed and maintained. PMID:25750789
Hamada, Yohei; Kitamura, Manami; Yamada, Yasuhiro; Sanada, Yoshinori; Sugihara, Takamitsu; Saito, Saneatsu; Moe, Kyaw; Hirose, Takehiro
2018-02-14
A new method for evaluating the in situ rock strength beneath the seafloor is proposed and applied to the Nankai Trough accretionary prism. The depth-continuous in situ rock strength is a critical parameter for numerous studies in earth science, particularly for seismology and tectonics at plate convergence zones; yet, measurements are limited owing to a lack of drilled cores. Here, we propose a new indicator of strength, the equivalent strength (EST), which is determined only by drilling performance parameters such as drill string rotational torque, bit depth, and string rotational speed. A continuous depth profile of EST was drawn from 0 to 3000 m below the seafloor (mbsf) across the forearc basin and accretionary prism in the Nankai Trough. The EST did not show a significant increase around the forearc basin-accretionary prism boundary, but it did show a clear increase within the prism, ca. below 1500 mbsf. This result may indicate that even the shallow accretionary prism has been strengthened by horizontal compression derived from plate subduction. The EST is a potential parameter to continuously evaluate the in situ rock strength during drilling, and its accuracy of the absolute value can be improved by combining with laboratory drilling experiments.
Niwa, Masahiro; Hiraishi, Yasuhiro
2014-01-30
Tablets are the most common form of solid oral dosage produced by pharmaceutical industries. There are several challenges to successful and consistent tablet manufacturing. One well-known quality issue is visible surface defects, which generally occur due to insufficient physical strength, causing breakage or abrasion during processing, packaging, or shipping. Techniques that allow quantitative evaluation of surface strength and the risk of surface defect would greatly aid in quality control. Here terahertz pulsed imaging (TPI) was employed to evaluate the surface properties of core tablets with visible surface defects of varying severity after film coating. Other analytical methods, such as tensile strength measurements, friability testing, and scanning electron microscopy (SEM), were used to validate TPI results. Tensile strength and friability provided no information on visible surface defect risk, whereas the TPI-derived unique parameter terahertz electric field peak strength (TEFPS) provided spatial distribution of surface density/roughness information on core tablets, which helped in estimating tablet abrasion risk prior to film coating and predicting the location of the defects. TPI also revealed the relationship between surface strength and blending condition and is a nondestructive, quantitative approach to aid formulation development and quality control that can reduce visible surface defect risk in tablets. Copyright © 2013 Elsevier B.V. All rights reserved.
A process-oriented measure of habit strength for moderate-to-vigorous physical activity.
Grove, J Robert; Zillich, Irja; Medic, Nikola
2014-01-01
Purpose : Habitual action is an important aspect of health behaviour, but the relevance of various habit strength indicators continues to be debated. This study focused specifically on moderate-to-vigorous physical activity (MVPA) and evaluated the construct validity of a framework emphasizing patterned action, stimulus-response bonding, automaticity, and negative consequences for nonperformance as indicators of habit strength for this form of exercise. Methods : Upper-level undergraduates ( N = 124) provided demographic information and responded to questionnaire items assessing historical MVPA involvement, current MVPA involvement, and the four proposed habit strength dimensions. Factor analyses were used to examine the latent structure of the habit strength indicators, and the model's construct validity was evaluated via an examination of relationships with repetition history and current behaviour. Results : At a measurement level, findings indicated that the proposed four-component model possessed psychometric integrity as a coherent set of factors. Criterion-related validity was also demonstrated via significant changes in three of the four factors as a function of past involvement in MVPA and significant correlations with the frequency, duration, and intensity of current MVPA. Conclusions : These findings support the construct validity of this exercise habit strength model and suggest that it could provide a template for future research on how MVPA habits are developed and maintained.
Ethnographic methods for process evaluations of complex health behaviour interventions.
Morgan-Trimmer, Sarah; Wood, Fiona
2016-05-04
This article outlines the contribution that ethnography could make to process evaluations for trials of complex health-behaviour interventions. Process evaluations are increasingly used to examine how health-behaviour interventions operate to produce outcomes and often employ qualitative methods to do this. Ethnography shares commonalities with the qualitative methods currently used in health-behaviour evaluations but has a distinctive approach over and above these methods. It is an overlooked methodology in trials of complex health-behaviour interventions that has much to contribute to the understanding of how interventions work. These benefits are discussed here with respect to three strengths of ethnographic methodology: (1) producing valid data, (2) understanding data within social contexts, and (3) building theory productively. The limitations of ethnography within the context of process evaluations are also discussed.
Venugopal, L; Lakshmi, M Narasimha; Babu, Devatha Ashok; Kiran, V Ravi
2014-01-01
Background: To test and compare the impact strength of fragment bonded teeth with that of intact teeth by using impact testing machine (pendulum type) as a mode of load. Materials and Methods: Forty extracted, maxillary, central incisors selected for this study (20 control group and 20 experimental group). In experimental group, teeth crowns were fractured with a microtome at 2.5 mm from mesioincisal angle cervically, fractured portion is attached to original crown portion with 3 M single bond dentin bonding agent and 3 M Z ‘100’, composite resin. Impact strength of fragment bonded teeth and intact teeth tested with impact testing machine and compared. Results: Mean impact strength of fragment bonded teeth (30.76 KJ/M2 ) is not statistically significant deferent from mean impact strength of intact teeth (31.11 KJ/M2 ). Conclusion: Mean impact strength of fragment bonded teeth is not statistically different with that of intact teeth. Hence, after fracture of teeth if it is restored with fragment reattachment by using 3 M single bond dentin bonding agent and 3 M Z ‘100’ composite resin is having impact strength like that of intact teeth. How to cite the article: Venugopal L, Lakshmi MN, Babu DA, Kiran VR. Comparative evaluation of impact strength of fragment bonded teeth and intact teeth: An in vitro study. J Int Oral Health 2014;6(3):73-6. PMID:25083037
A Study of Three Intrinsic Problems of the Classic Discrete Element Method Using Flat-Joint Model
NASA Astrophysics Data System (ADS)
Wu, Shunchuan; Xu, Xueliang
2016-05-01
Discrete element methods have been proven to offer a new avenue for obtaining the mechanics of geo-materials. The standard bonded-particle model (BPM), a classic discrete element method, has been applied to a wide range of problems related to rock and soil. However, three intrinsic problems are associated with using the standard BPM: (1) an unrealistically low unconfined compressive strength to tensile strength (UCS/TS) ratio, (2) an excessively low internal friction angle, and (3) a linear strength envelope, i.e., a low Hoek-Brown (HB) strength parameter m i . After summarizing the underlying reasons of these problems through analyzing previous researchers' work, flat-joint model (FJM) is used to calibrate Jinping marble and is found to closely match its macro-properties. A parametric study is carried out to systematically evaluate the micro-parameters' effect on these three macro-properties. The results indicate that (1) the UCS/TS ratio increases with the increasing average coordination number (CN) and bond cohesion to tensile strength ratio, but it first decreases and then increases with the increasing crack density (CD); (2) the HB strength parameter m i has positive relationships to the crack density (CD), bond cohesion to tensile strength ratio, and local friction angle, but a negative relationship to the average coordination number (CN); (3) the internal friction angle increases as the crack density (CD), bond cohesion to tensile strength ratio, and local friction angle increase; (4) the residual friction angle has little effect on these three macro-properties and mainly influences post-peak behavior. Finally, a new calibration procedure is developed, which not only addresses these three problems, but also considers the post-peak behavior.
ERIC Educational Resources Information Center
Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A.
2013-01-01
Objective: To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. Methods" A systematic literature review…
Evaluating an Adaptive Equity-Oriented Pedagogy: A Study of Its Impacts in Higher Education
ERIC Educational Resources Information Center
Phuong, Andrew Estrada; Nguyen, Judy; Marie, Dena
2017-01-01
This study examines whether and how an adaptive equity-oriented pedagogy can address diverse college students' needs and preferred modes of learning. Using a mixed-methods approach, we evaluated this pedagogical intervention that synthesizes democratic, assessment-driven, strengths-based, multimodal, and game-based instructional strategies. This…
Lee, Jung-Jin; Choi, Jung-Yun; Seo, Jae-Min
2017-04-01
The purpose of this study was to evaluate the effect of nano-structured alumina surface coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements. A total of 90 disk-shaped zirconia specimens (HASS CO., Gangneung, Korea) were divided into three groups by surface treatment method: (1) airborne particle abrasion, (2) tribochemicalsilica coating, and (3) nano-structured alumina coating. Each group was categorized into three subgroups of ten specimens and bonded with three different types of dual-cured resin cements. After thermocycling, shear bond strength was measured and failure modes were observed through FE-SEM. Two-way ANOVA and the Tukey's HSD test were performed to determine the effects of surface treatment method and type of cement on bond strength ( P <.05). To confirm the correlation of surface treatment and failure mode, the Chi-square test was used. Groups treated with the nanostructured alumina coating showed significantly higher shear bond strength compared to other groups treated with airborne particle abrasion or tribochemical silica coating. Clearfil SA Luting showed a significantly higher shear bond strength compared to RelyX ARC and RelyX Unicem. The cohesive failure mode was observed to be dominant in the groups treated with nano-structured alumina coating, while the adhesive failure mode was prevalent in the groups treated with either airborne particle abrasion or tribochemical silica coating. Nano-structured alumina coating is an effective zirconia surface treatment method for enhancing the bond strength between Y-TZP ceramic and various dual-cured resin cements.
Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A
2017-11-01
Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.
Zhang, Zhe-Chen; Qian, Yu-Fen; Yang, Yi-Ming; Feng, Qi-Ping; Shen, Gang
2016-09-01
The purpose of this work was to evaluate the effects of several surface treatment methods on the shear bond strengths of metal brackets bonded to a silica-based ceramic with a light-cured adhesive. Silica-based ceramic (IPS Classic(®)) with glazed surfaces was cut into discs that were used as substrates. A total of 80 specimens were randomly divided into four groups according to the method used: 9.6 % hydrofluoric acid (group 1), 9.6 % hydrofluoric acid (HF) + silane coupling agent (group 2), sandblasting (aluminum trioxide, 50 μm) + silane (group 3), and tribochemical silica coating (CoJet™ sand, 30 μm) + silane (group 4). Brackets were bonded to the treated specimens with a light-cure adhesive (Transbond XT, 3 M Unitek). Shear bond strength was tested after bracket bonding, and the Adhesive Remnant Index (ARI) scores were quantified after debonding. Group 4 showed the highest bond strength (12.3 ± 1.0 MPa), which was not significantly different from that of group 3 (11.6 ± 1.2 MPa, P > 0.05); however, the bond strength of group 4 was substantially higher than that of group 2 (9.4 ± 1.1 MPa, P < 0.05). The shear bond strength of group 1 (3.1 ± 0.6 MPa, P< 0.05) was significantly lower than that of the other groups. Shear bond strengths exceeded the optimal range of ideal bond strength for clinical practice, except for the isolated HF group. HF acid etching followed by silane was the best suited method for bonding on IPS Classic(®). Failure modes in the sandblasting and silica-coating groups revealed signs of damaged ceramic surfaces.
Tanış, Merve Çakırbay; Akçaboy, Cihan
2015-01-01
Introduction: Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. Methods: 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Results: Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group III surface microcracks connecting each other were observed. Conclusion: Tribochemical silica coating is an effective method for achieving an acceptable bond between zirconia and resin cement. Use of a MDP monomer containing resin cement increases the bond strength of sandblasted zirconia. PMID:26705464
Rani, Sapna; Verma, Mahesh; Gill, Shubhra; Gupta, Rekha
2016-01-01
Background/Purpose: The aim of this study was to compare the shear bond strength of computer aided design/computer aided machined ceramic (CAD/CAM), pressable ceramic, and milled metal implant copings on abutment and the effect of surface conditioning on bonding strength. Materials and Methods: A total of 90 test samples were fabricated on three titanium abutments. Among 90 test samples, 30 copings were fabricated by CAD/CAM, 30 by pressable, and 30 by milling of titanium metal. These 30 test samples in each group were further subdivided equally for surface treatment. Fifteen out of 30 test samples in each group were surface conditioned with airborne particle abrasion. All the 90 test samples were luted on abutment with glass ionomer cement. Bonding strength was evaluated for all the samples using universal testing machine at a crosshead speed of 5 mm/min. The results obtained were compared and evaluated using one-way ANOVA with post-hoc and unpaired t-test at a significance level of 0.05. Results: The mean difference for CAD/CAM surface conditioned subgroup was 1.28 ± 0.12, for nonconditioned subgroup was 1.20 ± 0.11. The mean difference for pressable surface conditioned subgroup was 1.18 ± 0.04, and for nonconditioned subgroup was 0.75 ± 0.28. The mean difference for milled metal surface conditioned subgroup was 2.57 ± 0.58, and for nonconditioned subgroup was 1.49 ± 0.15. Conclusions: On comparison of bonding strength, milled metal copings had an edge over the other two materials, and surface conditioning increased the bond strength. PMID:27141163
Reference values for muscle strength: a systematic review with a descriptive meta-analysis.
Benfica, Poliana do Amaral; Aguiar, Larissa Tavares; Brito, Sherindan Ayessa Ferreira de; Bernardino, Luane Helena Nunes; Teixeira-Salmela, Luci Fuscaldi; Faria, Christina Danielli Coelho de Morais
2018-05-03
Muscle strength is an important component of health. To describe and evaluate the studies which have established the reference values for muscle strength on healthy individuals and to synthesize these values with a descriptive meta-analysis approach. A systematic review was performed in MEDLINE, LILACS, and SciELO databases. Studies that investigated the reference values for muscle strength of two or more appendicular/axial muscle groups of health individuals were included. Methodological quality, including risk of bias was assessed by the QUADAS-2. Data extracted included: country of the study, sample size, population characteristics, equipment/method used, and muscle groups evaluated. Of the 414 studies identified, 46 were included. Most of the studies had adequate methodological quality. Included studies evaluated: appendicular (80.4%) and axial (36.9%) muscles; adults (78.3%), elderly (58.7%), adolescents (43.5%), children (23.9%); isometric (91.3%) and isokinetic (17.4%) strength. Six studies (13%) with similar procedures were synthesized with meta-analysis. Generally, the coefficient of variation values that resulted from the meta-analysis ranged from 20.1% to 30% and were similar to those reported by the original studies. The meta-analysis synthesized the reference values of isometric strength of 14 muscle groups of the dominant/non-dominant sides of the upper/lower limbs of adults/elderly from developed countries, using dynamometers/myometer. Most of the included studies had adequate methodological quality. The meta-analysis provided reference values for the isometric strength of 14 appendicular muscle groups of the dominant/non-dominant sides, measured with dynamometers/myometers, of men/women, of adults/elderly. These data may be used to interpret the results of the evaluations and establish appropriate treatment goals. Copyright © 2018 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Demirtas, Hatice Kubra; Akin, Mehmet; Ileri, Zehra; Basciftci, Faruk Ayhan
2015-01-01
The aim of this study was to evaluate the effects of different surface preparation methods on the shear bond strength (SBS) of orthodontic metal brackets to aged nano-hybrid resin composite surfaces in vitro. A total of 100 restorative composite resin discs, 6 mm in diameter and 3 mm thick, were obtained and treated with an ageing procedure. After ageing, the samples were randomly divided as follows according to surface preparation methods: (1)Control, (2)37% phosphoric acid gel, (3)Sandblasting, (4)Diamond bur, (5)Air-flow and 20 central incisor teeth were used for the control etched group. SBS test were applied on bonded metal brackets to all samples. SBS values and residual adhesives were evaluated. Analysis of variance showed a significant difference (p<0.001) between the groups. Sandblasted group had the highest SBS value (12.85 MPa) in experimental groups. The sandblasting surface treatment is recommended as an effective method of bonding orthodontic metal brackets to nano-hybrid composite resin surfaces.
NASA Astrophysics Data System (ADS)
Song, Jun Hee; Kim, Hak Kun; Kim, Sam Yeon
2014-07-01
Laminated fiber-reinforced composites can be applied to an insulating structure of a nuclear fusion device. It is necessary to investigate the interlaminar fracture characteristics of the laminated composites for the assurance of design and structural integrity. The three methods used to prepare the glass fiber reinforced plastic composites tested in this study were vacuum pressure impregnation, high pressure laminate (HPL), and prepreg laminate. We discuss the design criteria for safe application of composites and the shear-compressive test methods for evaluating mechanical properties of the material. Shear-compressive tests could be performed successfully using series-type test jigs that were inclined 0°, 30°, 45°, 60°, and 75° to the normal axis. Shear strength depends strongly on the applied compressive stress. The design range of allowable shear stress was extended by use of the appropriate composite fabrication method. HPL had the largest design range, and the allowable interlaminar shear stress was 0.254 times the compressive stress.
Effect of sintering process and additives on the properties of cordierite based ceramics
NASA Astrophysics Data System (ADS)
Rundans, M.; Sperberga, I.; Sedmale, G.; Stinkulis, G.
2013-12-01
It is possible to obtain cordierite ceramics with high temperature synthesis using both synthetic and raw natural materials. This paper discusses the possibilities to obtain cordierite ceramics, replacing part of required oxides with raw materials from various Latvian deposits of dolomite and clay. The obtained raw cordierite powders were ground in two modes (3 and 12 hours) and fired at 1200 °C. Ceramic samples were characterized by hydrostatic weighting method; crystalline phase composition was studied by XRD. Obtained samples were evaluated by their mechanical (compressive) strength and linear coefficient of thermal expansion (CTE). Thermal shock resistance was tested using water quenching method and afterwards evaluated by using ultrasonic method to test changes in Young's modulus of elasticity. Results show that increase in grinding time causes samples to densify and promote formation of cordierite crystalline phase which corresponds to increase in total compressive strength and decrease of CTE values. CTE values of samples ground for 12 hours conform to that of obtained in other researches.
Yildirim, T; Ayar, M K; Yesilyurt, C; Kilic, S
2016-01-01
The aim of the present study was to compare two different bond strength test methods (tensile and microtensile) in investing the influence of erbium, chromium: yttrium-scandium-gallium-garnet (Er, Cr: YSGG) laser pulse frequency on resin-enamel bonding. One-hundred and twenty-five bovine incisors were used in the present study. Two test methods were used: Tensile bond strength (TBS; n = 20) and micro-TBS (μTBS; n = 5). Those two groups were further split into three subgroups according to Er, Cr: YSGG laser frequency (20, 35, and 50 Hz). Following adhesive procedures, microhybrid composite was placed in a custom-made bonding jig for TBS testing and incrementally for μTBS testing. TBS and μTBS tests were carried out using a universal testing machine and a microtensile tester, respectively. Analysis of TBS results showed that means were not significantly different. For μTBS, the Laser-50 Hz group showed the highest bond strength (P < 0.05), and increasing frequency significantly increased bond strength (P < 0.05). Comparing the two tests, the μTBS results showed higher means and lower standard deviations. It was demonstrated that increasing μTBS pulse frequency significantly improved immediate bond strength while TBS showed no significant effect. It can, therefore, be concluded that test method may play a significant role in determining optimum laser parameters for resin bonding.
Lanying Lin; Sheng He; Feng Fu; Xiping Wang
2015-01-01
Wood failure percentage (WFP) is an important index for evaluating the bond strength of plywood. Currently, the method used for detecting WFP is visual inspection, which lacks efficiency. In order to improve it, image processing methods are applied to wood failure detection. The present study used thresholding and K-means clustering algorithms in wood failure detection...
NASA Astrophysics Data System (ADS)
Matsumoto, Yu; Takai, Kenichi
2018-02-01
A stress application method in delayed fracture susceptibility tests was investigated using 1450 MPa class tempered martensitic steel. Its fracture mode under hydrogen charging was mainly intergranular because of its relatively small Si content of 0.21 mass pct. The conditions for consistency in fracture strength between tensile tests and constant load tests (CLTs) were clarified: first, to conduct hydrogen precharging before stress application; and second, to choose a sufficiently low crosshead speed in tensile tests. When hydrogen precharging was not conducted before CLTs, the fracture strength was higher than the values in CLTs with hydrogen charging and in tensile tests. If the crosshead speed was too high, the fracture strength obtained was higher than the values in CLTs. The dependence of the fracture strength on crosshead speed was seen for both notched and smooth bar specimens. These results suggested that plastic deformation, i.e., dislocation motion, was related to intergranular fracture with a tear pattern as well as to quasi-cleavage fracture. In addition, cathodic electrolysis in an alkaline solution containing NaOH should be used as the hydrogen charging method to avoid the effects of corrosion.
NASA Technical Reports Server (NTRS)
Kautz, Harold E.; Bhatt, Ramakrishna T.
1991-01-01
A technique for measuring ultrasonic velocity was used to monitor changes that occur during processing and heat treatment of a SiC/RBSM composite. Results indicated that correlations exist between the ultrasonic velocity data and elastic modulus and interfacial shear strength data determined from mechanical tests. The ultrasonic velocity data can differentiate strength. The advantages and potential of this nondestructive evaluation method for fiber reinforced ceramic matrix composite applications are discussed.
NASA Technical Reports Server (NTRS)
Reid, Christopher; Harvill, Lauren; England, Scott; Young, Karen; Norcross, Jason; Rajulu, Sudhakar
2014-01-01
The objective of this project was to assess the performance differences between a nominally sized Extravehicular Mobility Unit (EMU) space suit and a nominal +1 (plus) sized EMU. Method: This study evaluated suit size conditions by using metabolic cost, arm mobility, and arm strength as performance metrics. Results: Differences between the suit sizes were found only in shoulder extension strength being 15.8% greater for the plus size. Discussion: While this study was able to identify motions and activities that were considered to be practically or statistically different, it does not signify that use of a plus sized suit should be prohibited. Further testing would be required that either pertained to a particular mission critical task or better simulates a microgravity environment that the EMU suit was designed to work in.
Durability evaluation of ceramic components using CARES/LIFE
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
1994-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Application of this design methodology is demonstrated using experimental data from alumina bar and disk flexure specimens which exhibit SCG when exposed to water.
Durability evaluation of ceramic components using CARES/LIFE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nemeth, N.N.; Janosik, L.A.; Gyekenyesi, J.P.
1996-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength andmore » fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Application of this design methodology is demonstrated using experimental data from alumina bar and disk flexure specimens, which exhibit SCG when exposed to water.« less
Lifetime Reliability Evaluation of Structural Ceramic Parts with the CARES/LIFE Computer Program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
1993-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker equation. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), Weibull's normal stress averaging method (NSA), or Batdorf's theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Two example problems demonstrating cyclic fatigue parameter estimation and component reliability analysis with proof testing are included.
Experimental study on beam for composite CES structural system
NASA Astrophysics Data System (ADS)
Matsui, Tomoya
2017-10-01
Development study on Concrete Encase Steel (CES) composite structure system has been continuously conducted toward the practical use. CES structure is composed of steel and fiber reinforced concrete. In previous study, it was found that CES structure has good seismic performance from experimental study of columns, beam - column joints, shear walls and a two story two span frame. However, as fundamental study on CES beam could be lacking, it is necessary to understand the structural performance of CES beam. In this study, static loading tests of CES beams were conducted with experimental valuable of steel size, the presence or absence of slab and thickness of slab. And restoring characteristics, failure behavior, deformation behavior, and strength evaluation method of CES beam were investigated. As the results, it was found that CES beam showed stable hysteresis behavior. Furthermore it was found that the flexural strength of the CES beam could be evaluated by superposition strength theory.
Morita, Yusuke; Yamasaki, Kenichi; Hattori, Koji
2010-10-01
It is difficult to quantitatively evaluate adhesive strength between an implant and the neighboring bone using animal experiments, because the degree of fixation of an implant depends on differences between individuals and the clearance between the material and the bone resulting from surgical technique. A system was designed in which rat bone marrow cells were used to quantitatively evaluate the adhesion between titanium alloy plates and bone plates in vitro. Three kinds of surface treatment were used: a sand-blasted surface, a titanium-sprayed surface and a titanium-sprayed surface coated with hydroxyapatite. Bone marrow cells obtained from rat femora were seeded on the titanium alloy plates, and the cells were cultured between the titanium alloy plates and the bone plates sliced from porcine ilium for 2 weeks. After cultivation, adhesive strength was measured using a tensile test, after which DNA amount and Alkaline phosphatase activity were measured. The seeded cells accelerated adhesion of the titanium alloy plate to the bone plate. Adhesive strength of the titanium-sprayed surface was lower than that of the sand-blasted surface because of lower initial contact area, although there was no difference in Alkaline phosphatase activity between two surface treatments. A hydroxyapatite coating enhanced adhesive strength between the titanium alloy palate and the bone plate, as well as enhancing osteogenic differentiation of bone marrow cells. It is believed that this novel experimental method can be used to simultaneously evaluate the osteogenic differentiation and the adhesive strength of an implant during in vitro cultivation. 2010 Elsevier Ltd. All rights reserved.
Low-temperature poly(oxymethylene) direct bonding via self-assembled monolayer
NASA Astrophysics Data System (ADS)
Fu, Weixin; Ma, Bo; Kuwae, Hiroyuki; Shoji, Shuichi; Mizuno, Jun
2018-02-01
A direct bonding of poly(oxymethylene) (POM) was feasible at 100 °C by using self-assembled monolayer (SAM) as a surface modification method. (3-aminopropyl)triethoxysilane (APTES) and (3-glycidyloxypropyl)trimethoxysilane (GOPTS) were used in our work. X-ray photoelectron spectroscopy showed that both APTES and GOPTS modified the POM surface successfully. Bonding strength evaluation revealed that surface modification was affected by pretreatment (VUV/O3) process time. In addition, the bonding condition with highest strength had an average strength of 372 kPa. This technology is expected to be used in packaging for micro-/nano-electromechanical systems, such as biomedical devices.
Influence of the processing route of porcelain/Ti-6Al-4V interfaces on shear bond strength.
Toptan, Fatih; Alves, Alexandra C; Henriques, Bruno; Souza, Júlio C M; Coelho, Rui; Silva, Filipe S; Rocha, Luís A; Ariza, Edith
2013-04-01
This study aims at evaluating the two-fold effect of initial surface conditions and dental porcelain-to-Ti-6Al-4V alloy joining processing route on the shear bond strength. Porcelain-to-Ti-6Al-4V samples were processed by conventional furnace firing (porcelain-fused-to-metal) and hot pressing. Prior to the processing, Ti-6Al-4V cylinders were prepared by three different surface treatments: polishing, alumina or silica blasting. Within the firing process, polished and alumina blasted samples were subjected to two different cooling rates: air cooling and a slower cooling rate (65°C/min). Metal/porcelain bond strength was evaluated by shear bond test. The data were analyzed using one-way ANOVA followed by Tuckey's test (p<0.05). Before and after shear bond tests, metallic surfaces and metal/ceramic interfaces were examined by Field Emission Gun Scanning Electron Microscope (FEG-SEM) equipped with Energy Dispersive X-Ray Spectroscopy (EDS). Shear bond strength values of the porcelain-to-Ti-6Al-4V alloy interfaces ranged from 27.1±8.9MPa for porcelain fused to polished samples up to 134.0±43.4MPa for porcelain fused to alumina blasted samples. According to the statistical analysis, no significant difference were found on the shear bond strength values for different cooling rates. Processing method was statistically significant only for the polished samples, and airborne particle abrasion was statistically significant only for the fired samples. The type of the blasting material did not cause a statistically significant difference on the shear bond strength values. Shear bond strength of dental porcelain to Ti-6Al-4V alloys can be significantly improved from controlled conditions of surface treatments and processing methods. Copyright © 2013 Elsevier Ltd. All rights reserved.
Control of embankment settlement field verification on PCPT prediction methods.
DOT National Transportation Integrated Search
2011-07-01
Piezocone penetration tests (PCPT) have been widely used by geotechnical engineers for subsurface investigation and evaluation of different soil properties such as strength and deformation characteristics of the soil. This report focuses on the verif...
Control of embankment settlement field verification on PCPT prediction methods.
DOT National Transportation Integrated Search
2011-07-01
Piezocone penetration tests (PCPT) have been widely used by geotechnical engineers for subsurface : investigation and evaluation of different soil properties such as strength and deformation characteristics of the : soil. This report focuses on the v...
Injection repair of carbon fiber/bismaleimide composite panels with bisphenol E cyanate ester resin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thunga, Mahendra; Bauer, Amy; Obusek, Kristine
2014-08-01
Resin injection of bisphenol E cyanate ester, a low viscosity resin that cures into a high temperature thermoset polymer, is investigated as a reliable repair method to restore strength and stiffness in delaminated carbon fiber/bismaleimide composites used in aircraft panels. The influence of temperature on the viscosity of the uncured resin was measured to optimize the injection conditions for high resin infiltration into the delaminations. The repair efficiency of the resin was evaluated by varying the panel thickness and the method by which the delamination damage was created in the composite specimens. Ultrasonic scanning (C-scan), flash thermography images, and cross-sectionmore » analysis of repaired panels revealed excellent resin infiltration into the damaged region. Evaluation of mechanical repair efficiency using both bending stiffness and in-plain compressive strength of the composite panels as the repair metrics showed values exceeding 100%.« less
Farokh Gisovar, Elham; Hedayati, Nassim; Shadman, Niloofar; Shafiee, Leila
2015-01-01
Background: CPP-ACP (Phosphopeptide-Amorphous Calcium Phosphate) has an important role in caries prevention in pediatric patients. This study was done, because of the great use of CPP-ACP and the need for restoration for teeth treated with CPP-ACP as well as the importance of shear bond strength of adhesives in the success of restorations. Objectives: This study aimed to evaluate the effect of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) on shear bond strength of dental adhesives to enamel of primary teeth molars. Materials and Methods: This in vitro study was conducted on 180 extracted primary molars. They were randomly divided into 6 groups and each group was divided into 2 subgroups (treated with CPP-ACP and untreated). In subgroups with CPP-ACP, enamel was treated with CPP-ACP paste 1 h/d for 5 days. Types of adhesives that were evaluated in this study were Tetric N-Bond, AdheSE, AdheSE One F, single Bond 2, SE Bond, and Adper Prompt L-Pop. Shear bond strength was tested with a universal testing machine and mode of failure was evaluated under stereomicroscope. Data were analyzed by T test, 2-way analysis of variance (ANOVA), Tukey and Fisher exact test using SPSS18. P < 0.05 was considered as significance level. Results: Shear bond strengths of different adhesive systems to enamel of primary teeth treated and untreated with CPP-ACP showed no significant difference (P > 0.05). Mode of failure in all groups regardless of CPP-ACP administration was mainly adhesive type. Our results indicated that CPP-ACP did not affect shear bond strength of studied adhesives to primary teeth enamel. Conclusions: To have a successful and durable composite restoration, having a high strength bonding is essential. Considering the wide use of CPP-ACP in preventing tooth decay and the role of adhesive shear bond strength (SBS) in success of composite restoration, we conducted the present study to evaluate the effect of CPP-ACP on the SBS of adhesives to primary teeth enamel. PMID:25793113
Composite impact strength improvement through a fiber/matrix interphase
NASA Technical Reports Server (NTRS)
Cavano, P. J.; Winters, W. E.
1975-01-01
Research was conducted to improve the impact strength and toughness of fiber/resin composites by means of a fiber coating interphase. Graphite fiber/epoxy resin composites were fabricated with four different fiber coating systems introduced in a matrix-fiber interphase. Two graphite fibers, a high strength and a high modulus type, were studied with the following coating systems: chemical vapor deposited boron, electroless nickel, a polyamide-imide resin and a thermoplastic polysulfone resin. Evaluation methods included the following tests: Izod, flexure, shear fracture toughness, longitudinal and transverse tensile, and transverse and longitudinal compression. No desirable changes could be effected with the high strength fiber, but significant improvements in impact performance were observed with the polyamide-imide resin coated high modulus fiber with no loss in composite modulus.
Gotti, Valeria Bisinoto; Feitosa, Victor Pinheiro; Sauro, Salvatore; Correr-Sobrinho, Lourenço; Correr, Americo Bortolazzo
2014-10-01
To evaluate the effects of an electric current-assisted application on the bond strength and interfacial morphology of self-adhesive resin cements bonded to dentin. Indirect resin composite build-ups were luted to prepared dentin surfaces using two self-adhesive resin cements (RelyX Unicem and BisCem) and an ElectroBond device under 0, 20, or 40 μA electrical current. All specimens were submitted to microtensile bond strength test and to interfacial SEM analysis. The electric current-assisted application induced no change (P > 0.05) on the overall bond strength, although RelyX Unicem showed significantly higher bond strength (P < 0.05) than BisCem. Similarly, no differences were observed in terms of interfacial integrity when using the electrical current applicator.
Nondestructive evaluation of standing trees with a stress wave method.
Xiping Wang; Robert J. Ross; Michael McClellan; R. James Barbour; John R. Erickson; John W. Forsman; Gary D. McGinnis
2001-01-01
The primary objective of this study was to investigate the usefulness of a stress wave technique for evaluating wood strength and stiffness of young-growth western hemlock and Sitka spruce in standing trees. A secondary objective was to determine if the effects of silvicultural practices on wood quality can be identified using this technique. Stress wave measurements...
Comparative study of mechanical properties of direct core build-up materials
Kumar, Girish; Shivrayan, Amit
2015-01-01
Background and Objectives: The strength greatly influences the selection of core material because core must withstand forces due to mastication and para-function for many years. This study was conducted to evaluate certain mechanical properties of commonly used materials for direct core build-up, including visible light cured composite, polyacid modified composite, resin modified glass ionomer, high copper amalgam, and silver cermet cement. Materials and Methods: All the materials were manipulated according to the manufacturer's recommendations and standard test specimens were prepared. A universal testing machine at different cross-head speed was used to determine all the four mechanical properties. Mean compressive strength, diametral tensile strength, flexural strength, and elastic modulus with standard deviations were calculated. Multiple comparisons of the materials were also done. Results: Considerable differences in compressive strength, diametral tensile strength, and flexural strength were observed. Visible light cured composite showed relatively high compressive strength, diametral tensile strength, and flexural strength compared with the other tested materials. Amalgam showed the highest value for elastic modulus. Silver cermet showed less value for all the properties except for elastic modulus. Conclusions: Strength is one of the most important criteria for selection of a core material. Stronger materials better resist deformation and fracture provide more equitable stress distribution, greater stability, and greater probability of clinical success. PMID:25684905
Respiratory Muscle Strength Predicts Decline in Mobility in Older Persons
Buchman, A.S.; Boyle, P.A.; Wilson, R.S.; Leurgans, S.; Shah, R.C.; Bennett, D.A.
2008-01-01
Objectives To test the hypothesis that respiratory muscle strength is associated with the rate of change in mobility even after controlling for leg strength and physical activity. Methods Prospective study of 890 ambulatory older persons without dementia who underwent annual clinical evaluations to examine change in the rate of mobility over time. Results In a linear mixed-effect model adjusted for age, sex, and education, mobility declined about 0.12 unit/year, and higher levels of respiratory muscle strength were associated with a slower rate of mobility decline (estimate 0.043, SE 0.012, p < 0.001). Respiratory muscle strength remained associated with the rate of change in mobility even after controlling for lower extremity strength (estimate 0.036, SE 0.012, p = 0.004). In a model that included terms for respiratory muscle strength, lower extremity strength and physical activity together, all three were independent predictors of mobility decline in older persons. These associations remained significant even after controlling for body composition, global cognition, the development of dementia, parkinsonian signs, possible pulmonary disease, smoking, joint pain and chronic diseases. Conclusion Respiratory muscle strength is associated with mobility decline in older persons independent of lower extremity strength and physical activity. Clinical interventions to improve respiratory muscle strength may decrease the burden of mobility impairment in the elderly. PMID:18784416
NASA Astrophysics Data System (ADS)
Du, Yicheng
Natural fibers have the potential to replace glass fibers in fiber-reinforced composite applications. However, the natural fibers' intrinsic properties cause these issues: (1) the mechanical property variation; (2) moisture uptake by natural fibers and their composites; (3) lack of sound, cost-effective, environment-friendly fiber-matrix compounding processes; (4) incompatibility between natural fibers and polymer matrices; and (5) low heat-resistance of natural fibers and their composites. This dissertation systematically studied the use of kenaf bast fiber bundles, obtained via a mechanical retting method, as a light-weight reinforcement material for fiber-reinforced thermoset polymer composites for automotive applications. Kenaf bast fiber bundle tensile properties were tested, and the effects of locations in the kenaf plant, loading rates, retting methods, and high temperature treatments and their durations on kenaf bast fiber bundle tensile properties were evaluated. A process has been developed for fabricating high fiber loading kenaf bast fiber bundle-reinforced unsaturated polyester composites. The generated composites possessed high elastic moduli and their tensile strengths were close to specification requirements for glass fiber-reinforced sheet molding compounds. Effects of fiber loadings and lengths on resultant composite's tensile properties were evaluated. Fiber loadings were very important for composite tensile modulus. Both fiber loadings and fiber lengths were important for composite tensile strengths. The distributions of composite tensile, flexural and impact strengths were analyzed. The 2-parameter Weibull model was found to be the most appropriate for describing the composite strength distributions and provided the most conservative design values. Kenaf-reinforced unsaturated polyester composites were also proved to be more cost-effective than glass fiber-reinforced SMCs at high fiber loadings. Kenaf bast fiber bundle-reinforced composite's water absorption properties were tested. Surface-coating and edge-sealing significantly reduced composite water resistance properties. Encapsulation was a practical method to improve composite water resistance properties. The molding pressure and styrene concentrations on composite and matrix properties were evaluated. Laser and plasma treatment improved fiber-to-matrix adhesion.
Formulation and evaluation of atenolol floating bioadhesive system using optimized polymer blends
Siddam, Haritha; Kotla, Niranjan G.; Maddiboyina, Balaji; Singh, Sima; Sunnapu, Omprakash; Kumar, Anil; Sharma, Dinesh
2016-01-01
Introduction: Oral sustained release gastro retentive dosage forms offer several advantages for drugs having absorption from the upper gastrointestinal tract to improve the bioavailability of medications which have narrow absorption window. The aim of the study was to develop a floating bioadhesive drug delivery system exhibiting a unique combination of floatation and bioadhesion to prolong the residence in the stomach using atenolol as a model drug. Methods: Prior to compression, polymeric blend(s) were evaluated for flow properties. The tablets were prepared by direct compression method using bioadhesive polymer like Carbopol 934P and hydrophilic polymers like HPMC K4M, HPMC K15M, and HPMC K100M. The prepared tablets were evaluated for physical characteristics, bioadhesive strength, buoyancy lag time, swelling index and in vitro drug release studies. Results: The mean bioadhesive strength was found to be in the range of 16.2 to 52.1 gm. The optimized blend (F11) showed 92.3% drug releases after 24 hrs. Whilst, increase in concentration of carbopol 934P, bioadhesive strength and swelling index was increased with slow release. The n values of optimized formulations were found in the range of 0.631-0.719 indicating non-fickian anomalous type transport mechanism. Conclusion: The study aided in developing an ideal once-a-day gastro retentive floating drug delivery system with improved floating, swelling and bioadhesive characteristics with better bioavailability. PMID:27051631
A Group Action Method for Construction of Strong Substitution Box
NASA Astrophysics Data System (ADS)
Jamal, Sajjad Shaukat; Shah, Tariq; Attaullah, Atta
2017-06-01
In this paper, the method to develop cryptographically strong substitution box is presented which can be used in multimedia security and data hiding techniques. The algorithm of construction depends on the action of a projective general linear group over the set of units of the finite commutative ring. The strength of substitution box and ability to create confusion is assessed with different available analyses. Moreover, the ability of resistance against malicious attacks is also evaluated. The substitution box is examined by bit independent criterion, strict avalanche criterion, nonlinearity test, linear approximation probability test and differential approximation probability test. This substitution box is equated with well-recognized substitution boxes such as AES, Gray, APA, S8, prime of residue, Xyi and Skipjack. The comparison shows encouraging results about the strength of the proposed box. The majority logic criterion is also calculated to analyze the strength and its practical implementation.
Olsen, M E; Bishara, S E; Damon, P; Jakobsen, J R
1997-05-01
Damage to the enamel surface during bonding and debonding of orthodontic brackets is a clinical concern. Alternative bonding methods that minimize enamel surface damage while maintaining a clinically useful bond strength is an aim of current research. The purpose of this study was to compare the effects on bond strength and bracket failure location of two adhesives (System 1+ and Scotchbond Multipurpose, 3M Dental Products Division) and two enamel conditioners (37% phosphoric acid and 10% maleic acid). Forty-eight freshly extracted human premolars were pumiced and divided into four groups of 12 teeth, and metal orthodontic brackets were attached to the enamel surface by one of four protocols: (1) System 1+ and phosphoric acid, (2) Scotchbond and phosphoric acid, (3) System 1+ and maleic acid, and (4) Scotchbond and maleic acid. After bracket attachment, the teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 72 hours. A Zwick universal testing machine (Zwick GmbH & Co.) was used to determine shear bond strengths. The residual adhesive on the enamel surface was evaluated with the Adhesive Remnant Index. The analysis of variance was used to compare the four groups. Significance was predetermined at p < or = 0.05. The results indicated that there were no significant differences in bond strength among the four groups (p = 0.386). The results of the Chi square test, evaluating the residual adhesives on the enamel surfaces, revealed significant differences among the four groups (mean 2 = 0.005). A Duncan multiple range test revealed the difference occurred between the phosphoric acid and maleic acid groups, with maleic acid having bond failures at the enamel-adhesive interface. In conclusion, the use of Scotchbond Multipurpose and/or maleic acid does not significantly effect bond strength, however, the use of maleic acid resulted in an unfavorable bond failure location.
CARES/LIFE Ceramics Analysis and Reliability Evaluation of Structures Life Prediction Program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Powers, Lynn M.; Janosik, Lesley A.; Gyekenyesi, John P.
2003-01-01
This manual describes the Ceramics Analysis and Reliability Evaluation of Structures Life Prediction (CARES/LIFE) computer program. The program calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. CARES/LIFE is an extension of the CARES (Ceramic Analysis and Reliability Evaluation of Structures) computer program. The program uses results from MSC/NASTRAN, ABAQUS, and ANSYS finite element analysis programs to evaluate component reliability due to inherent surface and/or volume type flaws. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing the power law, Paris law, or Walker law. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled by using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. The probabilistic time-dependent theories used in CARES/LIFE, along with the input and output for CARES/LIFE, are described. Example problems to demonstrate various features of the program are also included.
X-ray computed tomography using curvelet sparse regularization.
Wieczorek, Matthias; Frikel, Jürgen; Vogel, Jakob; Eggl, Elena; Kopp, Felix; Noël, Peter B; Pfeiffer, Franz; Demaret, Laurent; Lasser, Tobias
2015-04-01
Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method's strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.
Evaluation of Rhenium Joining Methods
NASA Technical Reports Server (NTRS)
Reed, Brian D.; Morren, Sybil H.
1995-01-01
Coupons of rhenium-to-Cl03 flat plate joints, formed by explosive and diffusion bonding, were evaluated in a series of shear tests. Shear testing was conducted on as-received, thermally-cycled (100 cycles, from 21 to 1100 C), and thermally-aged (3 and 6 hrs at 1100 C) joint coupons. Shear tests were also conducted on joint coupons with rhenium and/or Cl03 electron beam welded tabs to simulate the joint's incorporation into a structure. Ultimate shear strength was used as a figure of merit to assess the effects of the thermal treatment and the electron beam welding of tabs on the joint coupons. All of the coupons survived thermal testing intact and without any visible degradation. Two different lots of as-received, explosively-bonded joint coupons had ultimate shear strengths of 281 and 310 MPa and 162 and 223 MPa, respectively. As-received, diffusion-bonded coupons had ultimate shear strengths of 199 and 348 MPa. For the most part, the thermally-treated and rhenium weld tab coupons had shear strengths slightly reduced or within the range of the as-received values. Coupons with Cl03 weld tabs experienced a significant reduction in shear strength. The degradation of strength appeared to be the result of a poor heat sink provided during the electron beam welding. The Cl03 base material could not dissipate heat as effectively as rhenium, leading to the formation of a brittle rhenium-niobium intermetallic.
Use of metal conditioner on reinforcement wires to improve denture repair strengths.
Shimizu, Hiroshi; Mori, Nobuaki; Takahashi, Yutaka
2008-03-01
The purpose of this study was to evaluate the transverse strength of denture base resin repaired with autopolymerizing resin and metal wire using a metal conditioner, along with the synergistic effect of a surface preparation for denture base resin. It was found that the use of Co-Cr-Ni wires air abraded with 50 microm alumina, followed by treatment with a metal conditioner and dichloromethane for denture base resin, was the most effective method for repairing fractured denture base resin.
NASA Astrophysics Data System (ADS)
Maisuradze, M. V.; Ryzhkov, M. A.; Yudin, Yu. V.; Kuklina, A. A.
2017-11-01
Special features of the transformations of supercooled austenite occurring under continuous cooling of a promising high-strength steel grade not standardized in the Russian Federation are determined. A method for evaluating the volume fractions of structure constituents formed in the steel as a result of cooling from 925°C at various constant rates within 0.025 - 75 K/sec is proposed and tested. The results are generalized in the form of a thermokinetic diagram of transformations of supercooled austenite.
Kurtulmus-Yilmaz, Sevcan; Aktore, Huseyin
2018-05-01
To evaluate the effects of airborne-particle abrasion (APA) and Er,Cr:YSGG laser irradiation on 4-point-flexural strength, phase transformation and morphologic changes of zirconia ceramics treated at pre-sintered or post-sintered stage. Three hundred and forty-two bar shaped zirconia specimens were milled with different sizes according to the flexural strength test (n = 10), X-ray diffraction (XRD) (n = 4) and field emission scanning electron microscope (FE-SEM) (n = 4) analyses. For each test protocol, specimens were divided into 4 main groups whether the surface treatments applied before or after sintering and whether the specimens received heat treatment or not as pre-sintered, post-sintered no-heat and post-sintered heat-treated groups, and a group was served as control. Main groups were further divided into 6 equal subgroups according to surface treatment method applied (2 W-, 3 W-, 4 W-, 5 W-, 6 W-laser irradiations and APA). Surface treatments were applied to pre-sintered groups before sintering and to post-sintered groups after sintering. Post-sintered heat-treated groups were subjected to veneer ceramic firing simulation after surface treatments. Flexural strength and flexural modulus values were statistically analysed and monoclinic phase content was calculated. Weibull analysis was used to evaluate strength reliability and fractographic analysis was conducted. Highest flexural strength values were detected at post-sintered no-heat APA and 4W-laser groups (P < 0.05). Pre-sintered groups showed statistically lower flexural strength values. Heat treatment decreased the strength of the specimens. Monoclinic phase content was only detected at post-sintered no-heat groups and the highest amount was detected at APA group. Rougher surfaces and deeper irregularities were detected at FE-SEM images pre-sintered groups. Application of surface treatments at pre-sintered stage may be detrimental for zirconia ceramics in terms of flexural strength. Treating the surface of zirconia ceramic before sintering process is not recommended due to significant decrease in flexural strength values. 2 W-4 W Er,Cr:YSGG laser irradiations can be regarded as alternative surface treatment methods when zirconia restoration would be subjected to veneer ceramic firing procedures. Copyright © 2018 Elsevier Ltd. All rights reserved.
Brogårdh, Christina; Flansbjer, Ulla-Britt; Carlsson, Håkan; Lexell, Jan
2015-10-01
Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. To evaluate the intra-rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. A test-retest design. A university hospital outpatient clinic. Twenty-eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra-class correlation coefficient, the mean difference between the test sessions (d¯), together with the 95% confidence intervals for d¯ , the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland-Altman graphs. A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP-it) was used to measure grip strength. Intra-rater reliability was high, with intra-class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%-24% for all strength measurements, and the SRD%, representing the smallest change for an individual person, ranged from 20%-67%. Muscle strength in the upper limbs can be reliably measured in persons with late effects of polio. However, the measurement errors indicate that the method is more suitable to detect changes in muscle strength for a group of persons than for an individual person. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Deasy, Margaret; Leahy, Edmund; Semciw, Adam Ivan
2016-08-01
Study Design Systematic review with meta-analysis. Background A complete understanding of impairments associated with knee osteoarthritis would optimize exercise interventions for people with knee osteoarthritis. Our current understanding of hip strength deficits in this population is based on studies with conflicting findings and small samples. There is a need to systematically review and pool current evidence. Objectives To determine whether hip strength deficits exist in people with symptomatic knee osteoarthritis. Methods Electronic databases (MEDLINE, CINAHL, Embase, the Cochrane Library, and PsycINFO) were searched through February 2016. Studies comparing hip strength in people diagnosed with symptomatic knee osteoarthritis to healthy control participants were included in the review. A meta-analysis with random effects was applied to relevant data from included studies and a modified Grading of Recommendations Assessment, Development and Evaluation approach was used to evaluate the quality of evidence for each pooled analysis. Results Five studies were included in the review. Meta-analysis revealed moderate-quality evidence of weaker isometric and isokinetic hip abduction strength in people with knee osteoarthritis (moderate difference: 7% to 24% weaker) and very low-quality evidence of no difference in isometric hip adduction strength. There was very low- to moderate-quality evidence of weaker isokinetic hip strength in the remaining planes of motion (moderate to large differences: 14% to 55% weaker). Conclusion Significant hip strength deficits exist in people with knee osteoarthritis. Hip strength assessment should be considered in clinical practice and may assist with directing targeted management strategies. Level of Evidence Symptom prevalence, level 1a-. J Orthop Sports PhysTher 2016;46(8):629-639. Epub3 Jul 2016. doi:10.2519/jospt.2016.6618.
Kılınç, Muhammed; Yıldırım, Sibel A.; Tan, Ersin
2015-01-01
Objective: To evaluate and compare the effects of exercise therapy and electrical stimulation on muscle strength and functional activities in patients with limb-girdle muscular dystrophy (LGMD). Methods: This controlled clinical trial included 24 subjects who were diagnosed with LGMD by the Neurology Department of the Hacettepe University Hospital, Ankara, Turkey and were referred to the Physical Therapy Department between May 2013 and December 2014. Subjects were enrolled into an electrical stimulation (11 patients) group, or an exercise therapy (13 patients) group. Results: The mean age of patients was 31.62 years in the electrical stimulation group, and 30.14 years in the exercise therapy group. The most important results in this controlled clinical study were that the muscle strength in both groups was significantly decreased and post-treatment evaluation results indicated that muscle strength of the Deltoideus was higher in the electrical stimulation group, and the difference between the groups was maintained in the follow-up period (p<0.05). However, the muscle strength of quadriceps was similar in both groups, according to the post-treatment and follow-up evaluation results (p>0.05). Additionally, the electrical stimulation group presented more obvious overall improvements than the exercise therapy group according to muscle strength, endurance, and timed performance tests. Conclusions: Since no definitive treatments currently exist for patients with LGMD, these results provide important information on the role of exercise therapy and electrical stimulation for clinicians working in rehabilitation. PMID:26166595
Chang, Rong; Little, Todd D
2018-06-01
In this article, we review three innovative methods: multiform protocols, visual analog scaling, and the retrospective pretest-posttest design that can be used in evaluation research. These three techniques have been proposed for decades, but unfortunately, they are still not utilized readily in evaluation research. Our goal is to familiarize researchers with these underutilized research techniques that could reduce personnel effort and costs for data collection while producing better inferences for a study. We begin by discussing their applications and special unique features. We then discuss each technique's strengths and limitations and offer practical tips on how to better implement these methods in evaluation research. We then showcase two recent empirical studies that implement these methods in real-world evaluation research applications.
Evaluation of Tack Coat Bond Strength Tests
DOT National Transportation Integrated Search
2018-05-01
Poor bonding between asphalt pavement overlays and the substrate pavement layer can greatly influence the long term performance of hot mix asphalt (HMA) in the form of premature cracking and fatigue. The primary method to achieve bonding between laye...
Evaluation of FRP repair method for cracked bridge members.
DOT National Transportation Integrated Search
2005-01-01
This research program was undertaken to investigate the effects Carbon Fiber Reinforced Polymers (CFRP) have on the shear strength on under-reinforced, lab-scale prestressed concrete (PC) bridge girders. Many bridges in the states of Missouri and Kan...
Effects of various final irrigants on the shear bond strength of resin-based sealer to dentin
Kandaswamy, Deivanayagam; Venkateshbabu, Nagendrababu; Arathi, Ganesh; Roohi, Riaz; Anand, Suresh
2011-01-01
Aim: This study has been designed to evaluate the effect of strong (MTAD) or soft (1- hydroxyethylidene – 1, 1-bisphosphonate (HEBP) final irrigating solution on the shear bond strength of AH plus sealer to coronal dentin. 17% EDTA was used as the reference. Materials and Methods: Forty freshly extracted human maxillary first premolars were prepared using different irrigation protocols (n=10). All the test groups had 1.3% NaOCl as initial rinse and followed by specific final rinse for each group: G1 – distilled water(control), G2 – 17% EDTA, G3- 18% HEBP and G4 – MTAD. Sections of polyethylene tubes that are 3mm long were filled with freshly mixed sealer and placed on the dentin surfaces. The bonding between the sealer and dentine surface was evaluated using shear bond testing. The values were statistically evaluated using one-way ANOVA followed by Tukey's test. Result: Significant difference was found among the irrigating regimes. EDTA showed highest bond strength followed by HEBP and MTAD PMID:21691504
Li, Hui; Yang, Jin; Li, Pan; Lan, Tianqing; Peng, Lincai
2017-03-15
We proposed a green and facile method to fabricate superhydrophobic paper in this study, which is layer-by-layer (LBL) deposition of TiO 2 nanoparticles/sodium alginate (ALG) multilayers on paper surface followed by an adsorption treatment of colloidal carnauba wax. The formation of TiO 2 /ALG multilayers on paper surface was characterized by X-ray photoelectron spectroscopy (XPS), zeta potential measurement, scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. The wetting property of modified paper was investigated by water contact angle (WCA) measurement. Moreover, the modified paper tensile strength has been evaluated. The results showed that WCA of paper modified with a wax-treated (TiO 2 /ALG) 3.5 multilayer reached up to 151.5°, and this obtained superhydrophobic paper exhibited improved tensile strength (increased by 4.1% compared to the pristine paper), excellent moisture-proofing property and high strength stability under high relative humidity condition, which might has a great potential for use in the liquid paper packaging and moisture-proof paper packaging. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Bowles, Kenneth J.
1992-01-01
To date, the effect of thermo-oxidative aging on unidirectional composite mechanical properties has been monitored by the measurement of interlaminar shear strength (ILSS) and either three or four point longitudinal flexural strength (LFS) of the composites being tested. Both results are affected by the fiber-to-matrix bonding, the former being dependent on the shear resistance of the interface and the latter on the degree of load sharing by the fibers through the fiber/matrix interface. Recently, fiber/matrix interfacial bond strengths have been monitored using a transverse flexural strength (TFS) test method. This test method was used to evaluate the effect of fiber surface treatment on the fiber/matrix bond. The interface bonding was varied in these tests using Hercules A-fibers with three-types of surfaces that produce bonds of poor, better, and good quality. The TFS was found not only to be sensitive to the bonding, but also to the aging time of unidirectional A-fiber/PMR-15 composites. This relationship reflects the mechanism by which the PMR-15 degrades during thermal aging.
Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics
Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan
2015-01-01
Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646
Kaleli, Necati; Saraç, Duygu
2017-07-01
Most studies evaluating dental laser sintering systems have focused on the marginal accuracy of the restorations. However, the bond strength at the metal-ceramic interface is another important factor that affects the survival of restorations, and currently, few studies focus on this aspect. The purpose of this in vitro study was to compare the porcelain bond strength of cobalt-chromium (Co-Cr) metal frameworks prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and laser cusing, a direct process powder-bed system. A total of 96 metal frameworks (n=24 in each group) were prepared by using conventional lost-wax (group C), milling (group M), DMLS (group LS), and direct process powder-bed (group LC) methods according to International Organization for Standardization standard ISO 9693-1. After porcelain application, a 3-point bend test was applied to each specimen by using a universal testing machine. Data were statistically analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Failure types at the metal-ceramic interfaces were examined using stereomicroscopy. Additionally, 1 specimen from each group was prepared for scanning electron microscopy analysis to evaluate the surface topography of metal frameworks. The mean bond strength was 38.08 ±3.82 MPa for group C, 39.29 ±3.51 MPa for group M, 40.73 ±3.58 MPa for group LS, and 41.24 ±3.75 MPa for group LC. Statistically significant differences were observed among the 4 groups (P=.016). All groups, except for LS, exhibited adhesive and mixed type bond failure. Both of the laser sintering methods were found to be successful in terms of metal-ceramic bond strength. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Arash, Valiollah; Anoush, Keivan; Rabiee, Sayed Mahmood; Rahmatei, Manuchehr; Tavanafar, Saeid
2015-01-01
Aims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth. In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method. Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy. The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.019 × 0.025-in stainless steel [SS], 0.018-in stainless steel [SS], 0.018-in Nickel-Titanium [Ni-Ti]) and compared with 15 uncoated steel brackets. In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets. Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets. SPSS 18 was used for data analysis with t-test. SEM and AFM results showed deposition of a uniform layer of silver, measuring 8-10 μm in thickness on bracket surfaces. Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.019 × 0.025-in SS and 0.018-in Ni-Ti, but it did not change the shear bond strength significantly. Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics. © Wiley Periodicals, Inc.
Kim, Beom-Su; Kang, Hyo Jin; Lee, Jun
2013-10-01
Cuttlefish bones (CBs) have emerged as attractive biomaterials because of their porous structure and components that can be converted into hydroxyapatite (HAp) via a hydrothermal reaction. However, their brittleness and low strength restrict their application in bone tissue engineering. Therefore, to improve the compressive strength of the scaffold following hydrothermal conversion to a HAp form of CB (CB-HAp), the scaffold was coated using a polycaprolactone (PCL) polymer at various concentrations. In this study, raw CB was successfully converted into HAp via a hydrothermal reaction. We then evaluated their surface properties and composition by scanning electron microscopy and X-ray diffraction analysis. The CB-HAp coated with PCL showed improved compressive performance and retained a microporous structure. The compressive strength was significantly increased upon coating with 5 and 10% PCL, by 2.09- and 3.30-fold, respectively, as compared with uncoated CB-HAp. However, coating with 10% PCL resulted in a reduction in porosity. Furthermore, an in vitro biological evaluation demonstrated that MG-63 cells adhered well, proliferated and were able to be differentiated on the PCL-coated CB-HAp scaffold, which was noncytotoxic. These results suggest that a simple coating method is useful to improve the compressive strength of CB-HAp for bone tissue engineering applications. Copyright © 2013 Wiley Periodicals, Inc.
Adabo, Gelson Luis; dos Santos Cruz, Carlos Alberto; Fonseca, Renata Garcia; Vaz, Luís Geraldo
2003-07-01
To evaluate the content of inorganic particles and the flexural strength of new condensable composites for posterior teeth in comparison to hybrid conventional composites. The determination of the content of inorganic particles was performed by mass weighing of a polymerized composite before and after the elimination of the organic phase. The volumetric particle content was determined by a practical method based on Archimedes' principle, which calculates the volume of the composite and their particles by differential mass measured in the air and in water. The flexural strength of three points was evaluated according to the norm ISO 4049:1988. The results showed the following filler content: Alert, 67.26%; Z-100, 65.27%; Filtek P 60, 62.34%; Ariston pHc, 64.07%; Tetric Ceram, 57.22%; Definite, 54.42%; Solitaire, 47.76%. In the flexural strength test, the materials presented the following decreasing order of resistance: Filtek P 60 (170.02 MPa)>Z-100 (151.34 MPa)>Tetric Ceram (126.14 MPa)=Alert (124.89 MPa)>Ariston pHc (102.00 MPa)=Definite (93.63 MPa)>Solitaire (56.71 MPa). New condensable composites for posterior teeth present a concentration of inorganic particles similar to those of hybrid composites but do not necessarily present higher flexural strength.
NASA Astrophysics Data System (ADS)
Luo, Xiaotao; Smith, Gregory M.; Sampath, Sanjay
2018-02-01
Adhesion of thermal spray (TS) coatings is an important system level property in coating design and application. Adhesive-based pull testing (ASTM C633) has long been used to evaluate coating/substrate bonding. However, this approach is not always suitable for high velocity spray coatings, for example, where adhesion strengths are routinely greater than the strength of the adhesive bonding agent used in the testing. In this work, a new approach has been proposed to evaluate the adhesion of TS coatings. A systematic investigation of the effects of substrate roughness on both the uniaxial tensile yield strength and traditional bond pull adhesive strength of HVOF Ni and Ni-5wt.%Al, as well as cold-sprayed Ni-coated laminates revealed a strong correlation between these two test methodologies for the respective materials and processes. This approach allows measurement of the adhesion response even where the adhesive method is not applicable, overcoming many of the issues in the traditional ASTM C633. Analysis of cracking patterns of the coatings after 10.5% strain was used to assess the adhesion and cohesion properties. The mechanisms which determine the load transfer between the substrate and the coating are also briefly discussed.
Shear bond strength of indirect composite material to monolithic zirconia
2016-01-01
PURPOSE This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (α=.05). RESULTS Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia. PMID:27555895
Stella, João Paulo Fragomeni; Oliveira, Andrea Becker; Nojima, Lincoln Issamu; Marquezan, Mariana
2015-01-01
OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding. METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%). RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased. CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface. PMID:26352845
Analysis of Shear Bond Strength and Morphology of Er:YAG Laser-Recycled Ceramic Orthodontic Brackets
Han, Ruo-qiao; Ji, Ling-fei; Ling, Chen
2016-01-01
Objective. The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. Materials and Methods. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Results. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Conclusion. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods. PMID:27047964
Prediction and Estimation of Scaffold Strength with different pore size
NASA Astrophysics Data System (ADS)
Muthu, P.; Mishra, Shubhanvit; Sri Sai Shilpa, R.; Veerendranath, B.; Latha, S.
2018-04-01
This paper emphasizes the significance of prediction and estimation of the mechanical strength of 3D functional scaffolds before the manufacturing process. Prior evaluation of the mechanical strength and structural properties of the scaffold will reduce the cost fabrication and in fact ease up the designing process. Detailed analysis and investigation of various mechanical properties including shear stress equivalence have helped to estimate the effect of porosity and pore size on the functionality of the scaffold. The influence of variation in porosity was examined by computational approach via finite element analysis (FEA) and ANSYS application software. The results designate the adequate perspective of the evolutionary method for the regulation and optimization of the intricate engineering design process.
NASA Astrophysics Data System (ADS)
Ferasat, Keyvan; Aashuri, Hossein; Kokabi, Amir Hossein; Shafizadeh, Mahdi; Nikzad, Siamak
2015-12-01
Semisolid stir joining has been under deliberation as a possible method for joining of copper alloys. In this study, the effect of temperature and rotational speed of stirrer on macrostructure evaluation and mechanical properties of samples were investigated. Optical microscopy and X-ray diffraction were performed for macro and microstructural analysis. A uniform micro-hardness profile was attained by semisolid stir joining method. The ultimate shear strength and bending strength of welded samples were improved in comparison with the cast sample. There is also lower area porosity in welded samples than the cast metal. The mechanical properties were improved by increasing temperature and rotational speed of the joining process.
Evaluation of Fiber Reinforced Cement Using Digital Image Correlation
Melenka, Garrett W.; Carey, Jason P.
2015-01-01
The effect of short fiber reinforcements on the mechanical properties of cement has been examined using a splitting tensile – digital image correlation (DIC) measurement method. Three short fiber reinforcement materials have been used in this study: fiberglass, nylon, and polypropylene. The method outlined provides a simple experimental setup that can be used to evaluate the ultimate tensile strength of brittle materials as well as measure the full field strain across the surface of the splitting tensile test cylindrical specimen. Since the DIC measurement technique is a contact free measurement this method can be used to assess sample failure. PMID:26039590
Damage detection and repair methods for GFRP bridge decks.
DOT National Transportation Integrated Search
2011-12-01
Glass fiber-reinforced polymer (GFRP) decks are being considered for use as a replacement for worn steel grid bridge : decks due to their high strength-to-weight ratio and fast installation time. In this research, two nondestructive evaluation : tech...
34 CFR 663.21 - What criteria does the Secretary use to evaluate an application for a fellowship?
Code of Federal Regulations, 2012 CFR
2012-07-01
... research methods to be used; (2) The relationship of the research to the literature on the topic and to... Secretary considers— (1) The overall strength of applicant's academic record (teaching, research...
34 CFR 663.21 - What criteria does the Secretary use to evaluate an application for a fellowship?
Code of Federal Regulations, 2010 CFR
2010-07-01
... research methods to be used; (2) The relationship of the research to the literature on the topic and to... Secretary considers— (1) The overall strength of applicant's academic record (teaching, research...
34 CFR 663.21 - What criteria does the Secretary use to evaluate an application for a fellowship?
Code of Federal Regulations, 2011 CFR
2011-07-01
... research methods to be used; (2) The relationship of the research to the literature on the topic and to... Secretary considers— (1) The overall strength of applicant's academic record (teaching, research...
34 CFR 663.21 - What criteria does the Secretary use to evaluate an application for a fellowship?
Code of Federal Regulations, 2014 CFR
2014-07-01
... research methods to be used; (2) The relationship of the research to the literature on the topic and to... Secretary considers— (1) The overall strength of applicant's academic record (teaching, research...
34 CFR 663.21 - What criteria does the Secretary use to evaluate an application for a fellowship?
Code of Federal Regulations, 2013 CFR
2013-07-01
... research methods to be used; (2) The relationship of the research to the literature on the topic and to... Secretary considers— (1) The overall strength of applicant's academic record (teaching, research...
Statistical methods for the quality control of steam cured concrete : final report.
DOT National Transportation Integrated Search
1971-01-01
Concrete strength test results from three prestressing plants utilizing steam curing were evaluated statistically in terms of the concrete as received and the effectiveness of the plants' steaming procedures. Control charts were prepared to show tren...
Ahn, Joonghee; Jung, Kyoung-Hwa; Son, Sung-Ae; Hur, Bock; Kwon, Yong-Hoon
2015-01-01
Objectives This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. Materials and Methods Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncan's post hoc test. Results In GB, XV and SE (pH ≤ 2), the bond strength was decreased significantly when the dentin was etched (p < 0.05). In BB, AE and SU (pH 2.4 - 2.7), additional etching did not affect the bond strength (p > 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. Conclusions The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin. PMID:25671215
Wasike, Chrilukovian B; Magothe, Thomas M; Kahi, Alexander K; Peters, Kurt J
2011-01-01
Animal recording in Kenya is characterised by erratic producer participation and high drop-out rates from the national recording scheme. This study evaluates factors influencing efficiency of beef and dairy cattle recording system. Factors influencing efficiency of animal identification and registration, pedigree and performance recording, and genetic evaluation and information utilisation were generated using qualitative and participatory methods. Pairwise comparison of factors was done by strengths, weaknesses, opportunities and threats-analytical hierarchical process analysis and priority scores to determine their relative importance to the system calculated using Eigenvalue method. For identification and registration, and evaluation and information utilisation, external factors had high priority scores. For pedigree and performance recording, threats and weaknesses had the highest priority scores. Strengths factors could not sustain the required efficiency of the system. Weaknesses of the system predisposed it to threats. Available opportunities could be explored as interventions to restore efficiency in the system. Defensive strategies such as reorienting the system to offer utility benefits to recording, forming symbiotic and binding collaboration between recording organisations and NARS, and development of institutions to support recording were feasible.
Mechanics aspects of NDE by sound and ultrasound
NASA Technical Reports Server (NTRS)
Fu, L. S.
1982-01-01
Nondestructive evaluation (NDE) is considered as a means to detect the energy release mechanism of defects and the interaction of microstructures within materials with sound waves and/or ultrasonic waves. Ultrasonic inspection involves the frequency range 20 kHz-1 GHz with amplitudes depending on the sensitivity of the test instrumentation. Pulse echo systems are most frequently used in NDE. Information is extracted from the signals through measurements of the signal velocity, attenuation, the acoustic emission when stress is applied, and calculation of the acoustoelastic coefficients. Fracture properties, tensile and shear strengths, the interlaminar shear strength, the cohesive strength, yield and impact strengths, the hardness, and the residual stress can be assayed by ultrasonic methods. Finally, attention is given to analytical treatment of the derived data, with mention given to transition matrix, integral equation, and eigenstrain approaches.
Solidification/stabilization of dredged marine sediments for road construction.
Wang, Dong Xing; Abriak, Nor Edine; Zentar, Rachid; Xu, WeiYa
2012-01-01
Cement/lime-based solidification is an environmentally sound solution for the management of dredged marine sediments, instead of traditional solutions such as immersion. Based on the mineralogical composition and physical characteristics of Dunkirk sediments, the effects of cement and lime are assessed through Atterberg limits, modified Proctor compaction, unconfined compressive strength and indirect tensile strength tests. The variation of Atterberg limits and the improvement in strength are discussed at different binder contents. The potential of sediments solidified with cement or lime for road construction is evaluated through a proposed methodology from two aspects: I-CBR value and material classification. The test results show the feasibility of solidified dredged sediments for beneficial use as a material in road construction. Cement is superior to lime in terms of strength improvement, and adding 6% cement is an economic and reasonable method to stabilize fine sediments.
Brindha, M.; Kumaran, N. Kurunji; Rajasigamani, K.
2014-01-01
Aim: The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Materials and Methods: Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. Result: The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Conclusion: Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys. PMID:25210383
Improving degradation resistance of sisal fiber in concrete through fiber surface treatment
NASA Astrophysics Data System (ADS)
Wei, Jianqiang; Meyer, Christian
2014-01-01
As part of an ongoing effort to improve the sustainability of reinforced concrete, recycled concrete aggregate is being considered together with natural fibers such as sisal fiber as replacement of synthetic reinforcement. Since natural fibers are known to undergo potential deterioration in the alkaline cement matrix especially in outdoor erosive environment, they need to be treated to improve their durability. This paper describes two such methods (thermal and Na2CO3 treatment) and evaluates their effects on the degradation resistance of sisal fiber and durability of sisal fiber-reinforced concrete with recycled concrete aggregate. Concrete specimens were subjected to cycles of wetting and drying to accelerate aging. The microstructure, tensile strength and Young's modulus of sisal fiber as well as the weight loss of the composite were evaluated. Of primary interest were the effects on compressive and splitting tensile strength of sisal fiber-reinforced concrete. Thermal treatment and Na2CO3 surface treatment were shown to improve the durability of the composite as measured by splitting tensile strength by 36.5% and 46.2% and the compressive strength by 31.1% and 45.4%, respectively. The mechanisms of these two treatment methods were also analyzed. The thermal treatment achieved improvement of cellulose's crystallization, which ensured the initial strength and improved durability of sisal fiber. A layer consisting of calcium carbonate sediments, which protects the internals of a fiber from the strong alkali solution formed in the cement hydration process, was formed and filled in pits and cavities on the Na2CO3 treated sisal fiber's surface to improve their corrosion resistance and durability and reduced the detrimental effects of Na+ ions on concrete.
A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation.
Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf
2017-07-01
This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes' inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of the evidence for a trace specimen, e.g. a fingermark, and a reference specimen, e.g. a fingerprint, to originate from common or different sources. Some theoretical aspects of probabilities necessary for this Guideline were discussed prior to its elaboration, which started after a workshop of forensic researchers and practitioners involved in this topic. In the workshop, the following questions were addressed: "which aspects of a forensic evaluation scenario need to be validated?", "what is the role of the LR as part of a decision process?" and "how to deal with uncertainty in the LR calculation?". The questions: "what to validate?" focuses on the validation methods and criteria and "how to validate?" deals with the implementation of the validation protocol. Answers to these questions were deemed necessary with several objectives. First, concepts typical for validation standards [1], such as performance characteristics, performance metrics and validation criteria, will be adapted or applied by analogy to the LR framework. Second, a validation strategy will be defined. Third, validation methods will be described. Finally, a validation protocol and an example of validation report will be proposed, which can be applied to the forensic fields developing and validating LR methods for the evaluation of the strength of evidence at source level under the following propositions. Copyright © 2016. Published by Elsevier B.V.
Gaddala, Naresh; Veeramachineni, Chandrasekhar
2015-01-01
Background Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. Aim The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Materials and Methods Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Results Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Conclusion Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear. PMID:26155568
Han, Ruo-qiao; Yang, Kai; Ji, Ling-fei; Ling, Chen
2016-01-01
The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p < 0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods.
Kajbafzadeh, Abdol-Mohammad; Khorramirouz, Reza; Kameli, Seyede Maryam; Hashemi, Javad; Bagheri, Amin
2017-01-01
This study undertook to create small-diameter vascular grafts and assess their structure and mechanical properties to withstand arterial implantation. Twenty samples of intact human internal mammary arteries (IMAs) were collected and decellularized using detergent-based methods. To evaluate residual cellular and extracellular matrix (ECM) components, histological analysis was performed. Moreover, collagen typing and ECM structure were analyzed by Picrosirius red and Movat's pentachrome staining. Scanning electron microscopy was also applied to assess microarchitecture of both endothelial and adventitial surfaces of native and decellularized arterial samples. Furthermore, mechanical tests were performed to evaluate the rigidity and suture strength of the arteries. Human IMAs were completely decellularized in all three segments (proximal, middle, and distal). ECM proteins such as collagen and elastic fibers were efficiently preserved and no structural distortion in intima, media, and adventitial surfaces was observed. The parameters of the mechanical tests revealed no significant differences in the mechanical properties of decellularized arteries in comparison to native arteries with considerable strength, suture retention, and stress relaxation (Young's modulus [MPa] = 0.22 ± 0.023 [native] and 0.22 ± 0.015 [acellular]; and suture strength 0.56 ± 0.19 [native] vs. 0.56 ± 0.12 [acellular], respectively). Decellularized IMA represents a potential arterial scaffold as an alternative to autologous grafts for future arterial bypass surgeries. By this technique, microarchitecture and mechanical integrity of decellularized arteries were considerably similar to native arteries. The goal of this study was to introduce an efficient method for complete decellularization of human IMA and evaluate the ECM and biomechanical properties.
Two Decades of WRF/CMAQ simulations over the continental ...
Confidence in the application of models for forecasting and regulatory assessments is furthered by conducting four types of model evaluation: operational, dynamic, diagnostic, and probabilistic. Operational model evaluation alone does not reveal the confidence limits that can be associated with modeled air quality concentrations. This paper presents novel approaches for performing dynamic model evaluation and for evaluating the confidence limits of ozone exceedances using the WRF/CMAQ model simulations over the continental United States for the period from 1990 to 2010. The methodology presented here entails spectral decomposition of ozone time series using the KZ filter to assess the variations in the strengths of the synoptic (i.e., weather-induced variation) and baseline (i.e., long-term variation attributable to emissions, policy, and trends) forcings embedded in the modeled and observed concentrations. A method is presented where the future year observations are estimated based on the changes in the concentrations predicted by the model applied to the current year observations. The proposed method can provide confidence limits for ozone exceedances for a given emission reduction scenario. We present and discuss these new approaches to identify the strengths of the model in representing the changes in simulated O3 air quality over the 21-year period. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates
NASA Astrophysics Data System (ADS)
Rasia, Rodolfo J.; Rasia-Valverde, Juana R.; Stoltz, Jean F.
1996-01-01
Laser backscattering is an excellent tool to investigate size and concentration of suspended particles. It was successfully applied to the analysis of erythrocyte aggregation. A method is proposed that applies laser backscattering to the evaluation of the strength of the immunologic erythrocyte agglutination by approaching the energy required for the mechanical dissociation of agglutinates. Mills and Snabre have proposed a theory of laser backscattering for erythrocyte aggregation analysis. It is applied here to analyze the dissociation process of erythrocyte agglutinates performed by imposing a constant shear rate to the agglutinate suspension in a couette viscometer until a dispersion of isolated red cells is attained. Experimental verifications of the method were performed on the erythrocytes of the ABO group reacting against an anti-A test serum in twofold series dilutions. Spent energy is approached by a numerical process carried out on the backscattered intensity data registered during mechanical dissociation. Velocities of agglutination and dissociation lead to the calculation of dissociation parameters These values are used to evaluate the strength of the immunological reaction and to discriminate weak subgroups of ABO system.
Schellenberg, Florian; Oberhofer, Katja; Taylor, William R.
2015-01-01
Background. Knowledge of the musculoskeletal loading conditions during strength training is essential for performance monitoring, injury prevention, rehabilitation, and training design. However, measuring muscle forces during exercise performance as a primary determinant of training efficacy and safety has remained challenging. Methods. In this paper we review existing computational techniques to determine muscle forces in the lower limbs during strength exercises in vivo and discuss their potential for uptake into sports training and rehabilitation. Results. Muscle forces during exercise performance have almost exclusively been analysed using so-called forward dynamics simulations, inverse dynamics techniques, or alternative methods. Musculoskeletal models based on forward dynamics analyses have led to considerable new insights into muscular coordination, strength, and power during dynamic ballistic movement activities, resulting in, for example, improved techniques for optimal performance of the squat jump, while quasi-static inverse dynamics optimisation and EMG-driven modelling have helped to provide an understanding of low-speed exercises. Conclusion. The present review introduces the different computational techniques and outlines their advantages and disadvantages for the informed usage by nonexperts. With sufficient validation and widespread application, muscle force calculations during strength exercises in vivo are expected to provide biomechanically based evidence for clinicians and therapists to evaluate and improve training guidelines. PMID:26417378
Razavi, Sonia M; Callegari, Gerardo; Drazer, German; Cuitiño, Alberto M
2016-06-30
An ultrasound measurement system was employed as a non-destructive method to evaluate its reliability in predicting the tensile strength of tablets and investigate the benefits of incorporating it in a continuous line, manufacturing solid dosage forms. Tablets containing lactose, acetaminophen, and magnesium stearate were manufactured continuously and in batches. The effect of two processing parameters, compaction force and level of shear strain were examined. Young's modulus and tensile strength of tablets were obtained by ultrasound and diametrical mechanical testing, respectively. It was found that as the blend was exposed to increasing levels of shear strain, the speed of sound in the tablets decreased and the tablets became both softer and mechanically weaker. Moreover, the results indicate that two separate tablet material properties (e.g., relative density and Young's modulus) are necessary in order to predict tensile strength. A strategy for hardness prediction is proposed that uses the existing models for Young's modulus and tensile strength of porous materials. Ultrasound testing was found to be very sensitive in differentiating tablets with similar formulation but produced under different processing conditions (e.g., different level of shear strain), thus, providing a fast, and non-destructive method for hardness prediction that could be incorporated to a continuous manufacturing process. Copyright © 2016 Elsevier B.V. All rights reserved.
Uncertainties in obtaining high reliability from stress-strength models
NASA Technical Reports Server (NTRS)
Neal, Donald M.; Matthews, William T.; Vangel, Mark G.
1992-01-01
There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.
Kömürcü, Erkam; Yüksel, Halil Yalçın; Ersöz, Murat; Aktekin, Cem Nuri; Hapa, Onur; Çelebi, Levent; Akbal, Ayla; Biçimoğlu, Ali
2014-12-01
The aim of this study was to evaluate the effect of knee position during wound closure (flexed vs. extended) in total knee arthroplasty on knee strength and function, as determined by knee society scores and isokinetic testing of extensor and flexor muscle groups. In a prospective, randomized, double-blind trial, 29 patients were divided in two groups: for Group 1 patients, surgical closing was performed with the knee extended, and for Group 2 patients, the knee flexed at 90°. All the patients were treated with the same anaesthesia method, surgical team, surgical technique, prosthesis type, and rehabilitation process. American Knee Society Score values and knee flexion degrees were recorded. Isokinetic muscle strength measurements of both knees in flexion and extension were taken using 60° and 180°/s angular velocity. The peak torque and total work values, isokinetic muscle strength differences, and total work difference values were calculated for surgically repaired and healthy knees. No significant difference in the mean American Knee Society Score values and knee flexion degrees was observed between the two groups. However, using isokinetic evaluation, a significant difference was found in the isokinetic muscle strength differences and total work difference of the flexor muscle between the two groups when patients were tested at 180°/s. Less loss of strength was detected in the isokinetic muscle strength differences of the flexor muscle in Group 2 (-4.2%) than in Group 1 (-23.1%). For patients undergoing total knee arthroplasty, post-operative flexor muscle strength is improved if the knee is flexed during wound closure. II.
Sutil, Bruna Gabrielle da Silva; Susin, Alexandre Henrique
2017-01-01
Abstract Objectives: To evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Material and Methods: Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and etch-and-rinse (ER) mode, adhesive temperature (20°C or 37°C) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm2 were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using two-way ANOVA and Tukey's test (α=5%). Results: Interaction between treatment and temperature was statistically significant for SbU applied in self-etch technique. Both dentin treatments showed higher bond strength for ER mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE technique. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Conclusions: Dentin surface treatment with sodium bicarbonate air abrasion improves bond strength of SbU, irrespective of adhesive application mode, which makes this approach an alternative to increase adhesive performance of Scotchbond Universal Adhesive to dentin. PMID:29069151
NASA Astrophysics Data System (ADS)
Kitauchi, H.; Nozaki, K.; Ito, H.; Kondo, T.; Tsuchiya, S.; Imamura, K.; Nagatsuma, T.; Ishii, M.
2014-12-01
We present our recent efforts on an evaluation of the numerical prediction method of electric field strength for ionospheric propagation of low frequency (LF) radio waves based on a wave-hop propagation theory described in Section 2.4 of Recommendation ITU-R P.684-6 (2012), "Prediction of field strength at frequencies below about 150 kHz," made by International Telecommunication Union Radiocommunication Sector (ITU-R). As part of the Japanese Antarctic Research Expedition (JARE), we conduct on-board measurements of the electric field strengths and phases of LF 40 kHz and 60 kHz of radio signals (call sign JJY) continuously along both the ways between Tokyo, Japan and Syowa Station, the Japanese Antarctic station, at 69° 00' S, 39° 35' E on East Ongul Island, Lützow-Holm Bay, East Antarctica. The measurements are made by a newly developed, highly sensitive receiving system installed on board the Japanese Antarctic research vessel (RV) Shirase. We obtained new data sets of the electric field strength up to approximately 13,000-14,000 km propagation of LF JJY 40 kHz and 60 kHz radio waves by utilizing a newly developed, highly sensitive receiving system, comprised of an orthogonally crossed double-loop antenna and digital-signal-processing lock-in amplifiers, on board RV Shirase during the 55th JARE from November 2013 to April 2014. We have made comparisons between those on-board measurements and the numerical predictions of field strength for long-range propagation of low frequency radio waves based on a wave-hop propagation theory described in Section 2.4 of Recommendation ITU-R P.684-6 (2012) to show that our results qualitatively support the recommended wave-hop theory for the great-circle paths approximately 7,000-8,000 km and 13,000-14,000 km propagations.
Monitoring the Softening of Aluminum-Alloy V95ochT2 Shapes by a Nondestructive Method
NASA Astrophysics Data System (ADS)
Shigapov, A. I.; Klimova, T. A.; Il'inkova, T. A.
2015-09-01
Correlation relations between the strength and the electrical conductivity of aluminum shapes are determined. The properties of alloy V95ochT2 are studied after different temperature-and-time actions. It is shown that the "dark spots" appearing on the surface of such shapes can be evaluated by a nondestructive eddy-current method.
Sumpter, Colin; McGill, Elizabeth; Dickie, Esther; Champo, Enes; Romeri, Ester; Egan, Matt
2016-05-26
Reducing the Strength is an increasingly popular intervention in which local authorities ask retailers to stop selling 'super-strength' beers and ciders. The intervention cannot affect alcohol availability, nor consumption, unless retailers participate. In this paper, we ask whether and why retailers choose or refuse to self-impose restrictions on alcohol sales in this way. Mixed method assessment of retailers' participation in Reducing the Strength in two London (UK) local authorities. Compliance rates and the cheapest available unit of alcohol at each store were assessed. Qualitative interviews with retailer managers and staff (n = 39) explored attitudes towards the intervention and perceptions of its impacts. Shops selling super-strength across both areas fell from 78 to 25 (18 % of all off-licences). The median price of the cheapest unit of alcohol available across all retailers increased from £0.29 to £0.33 and in shops that participated in Reducing the Strength it rose from £0.33 to £0.43. The project received a mixed response from retailers. Retailers said they participated to deter disruptive customers, reduce neighbourhood disruptions and to maintain a good relationship with the local authority. Reducing the Strength participants and non-participants expressed concern about its perceived financial impact due to customers shopping elsewhere for super-strength. Some felt that customers' ability to circumvent the intervention would limit its effectiveness and that a larger scale compulsory approach would be more effective. Reducing the Strength can achieve high rates of voluntary compliance, reduce availability of super-strength and raise the price of the cheapest available unit of alcohol in participating shops. Questions remain over the extent to which voluntary interventions of this type can achieve wider social or health goals if non-participating shops attract customers from those who participate.
Evaluation of Explosive Strength for Young and Adult Athletes
ERIC Educational Resources Information Center
Viitasalo, Jukka T.
1988-01-01
The reliability of new electrical measurements of vertical jumping height and of throwing velocity was tested. These results were compared to traditional measurement techniques. The new method was found to give reliable results from children to adults. Methodology is discussed. (Author/JL)
Methodologies in determining mechanical properties of thin films using nanoindentation
NASA Astrophysics Data System (ADS)
Han, Seung Min Jane
Thin films are critical components of microelectronic and MEMS devices, and evaluating their mechanical properties is of current interest. As the dimensions of the devices become smaller and smaller, however, understanding the mechanical properties of materials at sub-micron length scales becomes more challenging. The conventional methods for evaluating strengths of materials in bulk form cannot be applied, and new methodologies are required for accurately evaluating mechanical properties of thin films. In this work, development of methodologies using the nanoindenter was pursued in three parts: (1) creation of a new method for extracting thin film hardness, (2) use of combinatorial methods for determining compositions with desired mechanical properties, and (3) use of microcompression testing of sub-micron sized pillars to understand plasticity in Al-Sc multilayers. The existing nanoindentation hardness model by Oliver & Pharr is unable to accurately determine the hardness of thin films on substrates with an elastic mismatch. Thus, a new method of analysis for extracting thin film hardness from film/substrate systems, that eliminates the effect of elastic mismatch of the underlying substrate, surface roughness, and also pile-up/sink-in, is needed. Such a method was developed in the first part of this study. The feasibility of using the nanoindentation hardness together with combinatorial methods to efficiently scan through mechanical properties of Ti-Al metallic alloys was examined in the second part of this study. The combinatorial approach provides an efficient method that can be used to determine alloy compositions that might merit further exploration and development as bulk materials. Finally, the mechanical properties of Al-Al3Sc multilayers with bilayer periods ranging from 6-100 nm were examined using microcompression. The sub-micron sized pillars were prepared using the focused ion beam (FIB) and compression tested with the flat tip of the nanoindenter. The measured yield strengths show the trend of increasing strength with decreasing bilayer period, and agree with the nanoindentation hardness results using the suitable Tabor correction factor. Strain softening was observed at large strains, and a new model for the true stress and true strain was developed to account for the inhomogeneous deformation geometry.
Teaching community diagnosis to medical students: evaluation of a case study approach.
Bair, C W
1980-01-01
A unique case study approach to training medical students in community diagnosis techniques was initiated at the Medical College of Ohio at Toledo. This paper describes the five elements of this teaching method: preliminary specification of target community and data base; group problem-solving requirement; specification of desired output; defined performance objectives; and regularly scheduled time for analysis. Experience with the case study method over two years was evaluated to identify specific strengths and weaknesses. The identified strengths include use of limited educational time to introduce community health problems, development of experience in a collegial team work setting, and specific awareness of the types of data useful to the analysis of community health service problems. Negative evaluations suggested that the method was not conducive to the development of skills in three areas: ability to establish the relative importance of health problems in communities; ability to identify an appropriate health system response to a community health problem from feasible alternatives; and ability to anticipate the community impact of health program modifications or improvements. Potential explanations for these deficiencies include: need for increased didactic support in the classroom for particular skill areas; need to establish a direct field experience in community diagnosis; inappropriateness of the data base used for evaluation of particular skills; and the probability that quantitative analysis, as used in this evaluation, may not be sufficient in and of itself to measure the outcome of a community diagnosis experience.
Evaluation of in-place concrete strength by core testing.
DOT National Transportation Integrated Search
2016-11-01
The overall objective of the work contained in this report is to develop an ALDOT procedure to evaluate core strength results obtained under various conditions. Since there are many factors that influence the apparent strength of cores, strength corr...
Evaluating the evaluation of cancer driver genes
Tokheim, Collin J.; Papadopoulos, Nickolas; Kinzler, Kenneth W.; Vogelstein, Bert; Karchin, Rachel
2016-01-01
Sequencing has identified millions of somatic mutations in human cancers, but distinguishing cancer driver genes remains a major challenge. Numerous methods have been developed to identify driver genes, but evaluation of the performance of these methods is hindered by the lack of a gold standard, that is, bona fide driver gene mutations. Here, we establish an evaluation framework that can be applied to driver gene prediction methods. We used this framework to compare the performance of eight such methods. One of these methods, described here, incorporated a machine-learning–based ratiometric approach. We show that the driver genes predicted by each of the eight methods vary widely. Moreover, the P values reported by several of the methods were inconsistent with the uniform values expected, thus calling into question the assumptions that were used to generate them. Finally, we evaluated the potential effects of unexplained variability in mutation rates on false-positive driver gene predictions. Our analysis points to the strengths and weaknesses of each of the currently available methods and offers guidance for improving them in the future. PMID:27911828
Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability
NASA Astrophysics Data System (ADS)
Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop
2018-02-01
We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.
Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability
NASA Astrophysics Data System (ADS)
Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop
2018-06-01
We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.
Evaluation the pozzolanic reactivity of sonochemically fabricated nano natural pozzolan.
Askarinejad, Azadeh; Pourkhorshidi, Ali Reza; Parhizkar, Tayebeh
2012-01-01
Natural pozzolans are appropriate supplementary cementitious materials in cement and concrete industry. A simple sonochemical method was developed to synthesize nanostructures of natural pozzolan. Chemical composition, crystallinity, morphology and reactivity of the natural pozzolan samples were compared before and after the sonochemical process, by using powder X-ray diffraction (XRD), Scanning Electron Microscopy (SEM), Thermal Gravimetry and Differential Thermal Analysis (TG/DTA). Compressive strength tests were performed to evaluate the properties of blended cements incorporating nano natural pozzolan. Under optimized conditions, the nano natural pozzolans showed a superior reactivity as compared with the bulk natural pozzolan. Also higher compressive strength was obtained for the cement specimen incorporating nano natural pozzolan. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-12-31
This Assessment was conducted to improve the National Earthquake Hazards Reduction Program (NEHRP) by providing NEHRP agencies with information that supports their user-oriented setting of crosscutting priorities in the NEHRP strategic planning process. The primary objective of this Assessment was to take a ``snapshot`` evaluation of the needs of selected users throughout the major program elements of NEHRP. Secondary objectives were to conduct an assessment of the knowledge that exists (or is being developed by NEHRP) to support earthquake risk reduction, and to begin a process of evaluating how NEHRP is meeting user needs. An identification of NEHRP`s strengths alsomore » resulted from the effort, since those strengths demonstrate successful methods that may be useful to NEHRP in the future. These strengths are identified in the text, and many of them represent important achievements since the Earthquake Hazards Reduction Act was passed in 1977.« less
Repeat work bouts increase thermal strain for Australian firefighters working in the heat.
Walker, Anthony; Argus, Christos; Driller, Matthew; Rattray, Ben
2015-01-01
Firefighters regularly re-enter fire scenes during long duration emergency events with limited rest between work bouts. It is unclear whether this practice is impacting on the safety of firefighters. To evaluate the effects of multiple work bouts on firefighter physiology, strength, and cognitive performance when working in the heat. Seventy-seven urban firefighters completed two 20-minute simulated search and rescue tasks in a heat chamber (105 ± 5°C), separated by a 10-minute passive recovery. Core and skin temperature, rate of perceived exertion (RPE), thermal sensation (TS), grip strength, and cognitive changes between simulations were evaluated. Significant increases in core temperature and perceptual responses along with declines in strength were observed following the second simulation. No differences for other measures were observed. A significant increase in thermal strain was observed when firefighters re-entered a hot working environment. We recommend that longer recovery periods or active cooling methods be employed prior to re-entry.
Alves, Christiano Robles Rodrigues; Merege Filho, Carlos Alberto Abujabra; Benatti, Fabiana Braga; Brucki, Sonia; Pereira, Rosa Maria R.; de Sá Pinto, Ana Lucia; Lima, Fernanda Rodrigues; Roschel, Hamilton; Gualano, Bruno
2013-01-01
Purpose To assess the effects of creatine supplementation, associated or not with strength training, upon emotional and cognitive measures in older woman. Methods This is a 24-week, parallel-group, double-blind, randomized, placebo-controlled trial. The individuals were randomly allocated into one of the following groups (n=14 each): 1) placebo, 2) creatine supplementation, 3) placebo associated with strength training or 4) creatine supplementation associated with strength training. According to their allocation, the participants were given creatine (4 x 5 g/d for 5 days followed by 5 g/d) or placebo (dextrose at the same dosage) and were strength trained or not. Cognitive function, assessed by a comprehensive battery of tests involving memory, selective attention, and inhibitory control, and emotional measures, assessed by the Geriatric Depression Scale, were evaluated at baseline, after 12 and 24 weeks of the intervention. Muscle strength and food intake were evaluated at baseline and after 24 weeks. Results After the 24-week intervention, both training groups (ingesting creatine supplementation and placebo) had significant reductions on the Geriatric Depression Scale scores when compared with the non-trained placebo group (p = 0.001 and p = 0.01, respectively) and the non-trained creatine group (p < 0.001 for both comparison). However, no significant differences were observed between the non-trained placebo and creatine (p = 0.60) groups, or between the trained placebo and creatine groups (p = 0.83). Both trained groups, irrespective of creatine supplementation, had better muscle strength performance than the non-trained groups. Neither strength training nor creatine supplementation altered any parameter of cognitive performance. Food intake remained unchanged. Conclusion Creatine supplementation did not promote any significant change in cognitive function and emotional parameters in apparently healthy older individuals. In addition, strength training per se improved emotional state and muscle strength, but not cognition, with no additive effects of creatine supplementation. Trial Registration Clinicaltrials.gov NCT01164020 PMID:24098469
Deeken, Corey R.; Matthews, Brent D.
2013-01-01
Purpose. Poly-4-hydroxybutyrate (P4HB) is a naturally derived, absorbable polymer. P4HB has been manufactured into PHASIX Mesh and P4HB Plug designs for soft tissue repair. The objective of this study was to evaluate mechanical strength, resorption properties, and histologic characteristics in a porcine model. Methods. Bilateral defects were created in the abdominal wall of n = 20 Yucatan minipigs and repaired in a bridged fashion with PHASIX Mesh or P4HB Plug fixated with SorbaFix or permanent suture, respectively. Mechanical strength, resorption properties, and histologic characteristics were evaluated at 6, 12, 26, and 52 weeks (n = 5 each). Results. PHASIX Mesh and P4HB Plug repairs exhibited similar burst strength, stiffness, and molecular weight at all time points, with no significant differences detected between the two devices (P > 0.05). PHASIX Mesh and P4HB Plug repairs also demonstrated significantly greater burst strength and stiffness than native abdominal wall at all time points (P < 0.05), and material resorption increased significantly over time (P < 0.001). Inflammatory infiltrates were mononuclear, and both devices exhibited mild to moderate granulation tissue/vascularization. Conclusions. PHASIX Mesh and P4HB Plug demonstrated significant mechanical strength compared to native abdominal wall, despite significant material resorption over time. Histological assessment revealed a comparable mild inflammatory response and mild to moderate granulation tissue/vascularization. PMID:23781348
Nasseri, Ehsan Baradaran; Majidinia, Sara; Sharbaf, Davood Aghasizadeh
2017-01-01
Background Based on the frequent application of composite resins as tooth-colored fillings, this method is considered a viable alternative to dental amalgam. However, this method has the low bond strength of the composite to dentin. To solve this issue, various dental adhesive systems with different characteristics have been developed by dentistry experts. Aim To assess the effect of an additional layer of unfilled resin in self-etch and total-etch dentin adhesives on the shear bond strength (SBS) of composite to dentin. Moreover, we assessed the effects of sample storage in artificial saliva on the SBS of composite to dentin. Methods Methods: This experimental study was conducted on 160 freshly extracted human first or second premolar teeth, which were randomly divided into 16 groups. The teeth were prepared from Mashhad University of Medical Sciences, Mashhad, Iran (2008–2009). Scotchbond Multi-purpose (SBMP), single bond (SB), Clearfil SE Bond, and Clearfil S3 Bond were applied to dentin surface with or without the placement of hydrophobic resin (Margin Bond) in accordance with the instructions of the manufacturers. To expose the coronal dentin, the teeth were abraded with 600 grit SiC paper. Immediately after restoration, half of the samples were tested in terms of SBS, while the other samples were evaluated in terms of SBS after three months of storage in artificial saliva. SBS rates of dental composites evaluated by universal testing machine and samples were studied by optical stereomicroscopy to verify the failure type. Data analysis was performed in SPSS V.16 using Kolmogorov-Smirnov test, independent-samples t-test, ANOVA, and Duncan’s logistic regression test. Results In this study, a significant reduction was observed in the SBS rates of SB and S3 bond adhesive systems after storage with and without hydrophobic resin (p>0.000). Without storage in normal saline, a significant increase was observed in the SBS rate of the SE bond (p=0.013). In addition, SBS rate of SBMP significantly increased after storage with hydrophobic resin (p=0.001). Finally, the highest and lowest rates of SBS were observed in the SE and S3 bonds in all the experimental groups, respectively. Conclusion The effects of using a hydrophobic resin layer on shear bond strength values seem to be effective. The mild self-etch adhesive exhibited the best resin-dentine bond strength after aging PMID:28713512
NASA Astrophysics Data System (ADS)
Nomoto, Yohei; Yamashita, Kazuhiko; Ohya, Tetsuya; Koyama, Hironori; Kawasumi, Masashi
There is the increasing concern of the society to prevent the fall of the aged. The improvement in aged people's the muscular strength of the lower-limb, postural control and walking ability are important for quality of life and fall prevention. The aim of this study was to develop multiple evaluation methods in order to advise for improvement and maintenance of lower limb function between aged and young. The subjects were 16 healthy young volunteers (mean ± S.D: 19.9 ± 0.6 years) and 10 healthy aged volunteers (mean ± S.D: 80.6 ± 6.1 years). Measurement items related to lower limb function were selected from the items which we have ever used. Selected measurement items of function of lower are distance of extroversion of the toe, angle of flexion of the toe, maximum width of step, knee elevation, moving distance of greater trochanter, walking balance, toe-gap force and rotation range of ankle joint. Measurement items summarized by the principal component analysis into lower ability evaluation methods including walking ability and muscle strength of lower limb and flexibility of ankle. The young group demonstrated the factor of 1.6 greater the assessment score of walking ability compared with the aged group. The young group demonstrated the factor of 1.4 greater the assessment score of muscle strength of lower limb compared with the aged group. The young group demonstrated the factor of 1.2 greater the assessment score of flexibility of ankle compared with the aged group. The results suggested that it was possible to assess the lower limb function of aged and young numerically and to advise on their foot function.
A simulator for evaluating methods for the detection of lesion-deficit associations
NASA Technical Reports Server (NTRS)
Megalooikonomou, V.; Davatzikos, C.; Herskovits, E. H.
2000-01-01
Although much has been learned about the functional organization of the human brain through lesion-deficit analysis, the variety of statistical and image-processing methods developed for this purpose precludes a closed-form analysis of the statistical power of these systems. Therefore, we developed a lesion-deficit simulator (LDS), which generates artificial subjects, each of which consists of a set of functional deficits, and a brain image with lesions; the deficits and lesions conform to predefined distributions. We used probability distributions to model the number, sizes, and spatial distribution of lesions, to model the structure-function associations, and to model registration error. We used the LDS to evaluate, as examples, the effects of the complexities and strengths of lesion-deficit associations, and of registration error, on the power of lesion-deficit analysis. We measured the numbers of recovered associations from these simulated data, as a function of the number of subjects analyzed, the strengths and number of associations in the statistical model, the number of structures associated with a particular function, and the prior probabilities of structures being abnormal. The number of subjects required to recover the simulated lesion-deficit associations was found to have an inverse relationship to the strength of associations, and to the smallest probability in the structure-function model. The number of structures associated with a particular function (i.e., the complexity of associations) had a much greater effect on the performance of the analysis method than did the total number of associations. We also found that registration error of 5 mm or less reduces the number of associations discovered by approximately 13% compared to perfect registration. The LDS provides a flexible framework for evaluating many aspects of lesion-deficit analysis.
Roemers, P; Mazzola, P N; De Deyn, P P; Bossers, W J; van Heuvelen, M J G; van der Zee, E A
2018-04-15
Voluntary strength training methods for rodents are necessary to investigate the effects of strength training on cognition and the brain. However, few voluntary methods are available. The current study tested functional and muscular effects of two novel voluntary strength training methods, burrowing (digging a substrate out of a tube) and unloaded tower climbing, in male C57Bl6 mice. To compare these two novel methods with existing exercise methods, resistance running and (non-resistance) running were included. Motor coordination, grip strength and muscle fatigue were measured at baseline, halfway through and near the end of a fourteen week exercise intervention. Endurance was measured by an incremental treadmill test after twelve weeks. Both burrowing and resistance running improved forelimb grip strength as compared to controls. Running and resistance running increased endurance in the treadmill test and improved motor skills as measured by the balance beam test. Post-mortem tissue analyses revealed that running and resistance running induced Soleus muscle hypertrophy and reduced epididymal fat mass. Tower climbing elicited no functional or muscular changes. As a voluntary strength exercise method, burrowing avoids the confounding effects of stress and positive reinforcers elicited in forced strength exercise methods. Compared to voluntary resistance running, burrowing likely reduces the contribution of aerobic exercise components. Burrowing qualifies as a suitable voluntary strength training method in mice. Furthermore, resistance running shares features of strength training and endurance (aerobic) exercise and should be considered a multi-modal aerobic-strength exercise method in mice. Copyright © 2017 Elsevier B.V. All rights reserved.
Moreno, Santiago G; Sutton, Alex J; Ades, A E; Cooper, Nicola J; Abrams, Keith R
2011-11-01
To extend, apply, and evaluate a regression-based approach to adjusting meta-analysis for publication and related biases. The approach uses related meta-analyses to improve estimation by borrowing strength on the degree of bias. The proposed adjustment approach is described. Adjustments are applied both independently and by borrowing strength across journal-extracted data on the effectiveness of 12 antidepressant drugs from placebo-controlled trials. The methods are also applied to Food and Drug Administration (FDA) data obtained on the same 12 drugs. Results are compared, viewing the FDA observed data as gold standard. Estimates adjusted for publication biases made independently for each drug were very uncertain using both the journal and FDA data. Adjusted estimates were much more precise when borrowing strength across meta-analyses. Reassuringly, adjustments in this way made to the journal data agreed closely with the observed estimates from the FDA data, while the adjusted FDA results changed only minimally from those observed from the FDA data. The method worked well in the case study considered and therefore further evaluation is encouraged. It is suggested that this approach may be especially useful when adjusting several meta-analyses on similar interventions and outcomes, particularly when there are small numbers of studies. Copyright © 2011 Elsevier Inc. All rights reserved.
In vitro evaluation of an alternative method to bond molar tubes
PINZAN-VERCELINO, Célia Regina Maio; PINZAN, Arnaldo; GURGEL, Júlio de Araújo; BRAMANTE, Fausto Silva; PINZAN, Luciana Maio
2011-01-01
Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. Objective The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. Material and methods Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey’s test (α=0.05). Results Group 1 had a significantly higher (p<0.05) shear bond strength compared to groups 2 and 3. No difference was detected between groups 2 and 3 (p>0.05). Conclusions The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes. PMID:21437468
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, J.L.; Krieger, M.J.
This paper is about the economic evaluation of diagnostic procedures. The issue of economic evaluation is explored in the context of four common diagnostic X-ray procedures: the chest X-ray, the skull X-ray, the barium enema study, and the excretory urogram. The paper is divided into two parts. The first part summarizes the different evaluative models underlying studies of the four diagnostic X-ray procedures and to lay out the strengths and weaknesses of each method. The second part contains four separate chapters summarizing what is known about the utilization, costs, risks, and benefits of each procedure, with particular emphasis on themore » evaluative methods employed.« less
Evaluation of composite adhesive bonds using digital image correlation
NASA Astrophysics Data System (ADS)
Shrestha, Shashi Shekhar
Advanced composite materials are widely used for many structural applications in the aerospace/aircraft industries today. Joining of composite structures using adhesive bonding offers several advantages over traditional fastening methods. However, this technique is not yet employed for fastening the primary structures of aircrafts or space vehicles. There are several reasons for this: There are not any reliable non-destructive evaluation (NDE) methods that can quantify the strength of the bonds, and there are no certifications of quality assurance for inspecting the bond quality. Therefore, there is a significant need for an effective, reliable, easy to use NDE method for the analysis of composite adhesive joints. This research aimed to investigate an adhesively bonded composite-aluminum joints of variable bond strength using digital image correlation (DIC). There are many future possibilities in continuing this research work. As the application of composite materials and adhesive bond are increasing rapidly, the reliability of the composite structures using adhesive bond should quantified. Hence a lot of similar research using various adhesive bonds and materials can be conducted for characterizing the behavior of adhesive bond. The results obtained from this research will set the foundation for the development of ultrasonic DIC as a nondestructive approach for the evaluation of adhesive bond line.
Brazed Joints Design and Allowables: Discuss Margins of Safety in Critical Brazed Structures
NASA Technical Reports Server (NTRS)
FLom, Yury
2009-01-01
This slide presentation tutorial discusses margins of safety in critical brazed structures. It reviews: (1) the present situation (2) definition of strength (3) margins of safety (4) design allowables (5) mechanical testing (6) failure criteria (7) design flowchart (8) braze gap (9) residual stresses and (10) delayed failures. This presentation addresses the strength of the brazed joints, the methods of mechanical testing, and our ability to evaluate the margins of safety of the brazed joints as it applies to the design of critical and expensive brazed assemblies.
Udhayakumar, Ganesan; Sujatha, Chinnaswamy Manoharan; Ramakrishnan, Swaminathan
2013-01-01
Analysis of bone strength in radiographic images is an important component of estimation of bone quality in diseases such as osteoporosis. Conventional radiographic femur bone images are used to analyze its architecture using bi-dimensional empirical mode decomposition method. Surface interpolation of local maxima and minima points of an image is a crucial part of bi-dimensional empirical mode decomposition method and the choice of appropriate interpolation depends on specific structure of the problem. In this work, two interpolation methods of bi-dimensional empirical mode decomposition are analyzed to characterize the trabecular femur bone architecture of radiographic images. The trabecular bone regions of normal and osteoporotic femur bone images (N = 40) recorded under standard condition are used for this study. The compressive and tensile strength regions of the images are delineated using pre-processing procedures. The delineated images are decomposed into their corresponding intrinsic mode functions using interpolation methods such as Radial basis function multiquadratic and hierarchical b-spline techniques. Results show that bi-dimensional empirical mode decomposition analyses using both interpolations are able to represent architectural variations of femur bone radiographic images. As the strength of the bone depends on architectural variation in addition to bone mass, this study seems to be clinically useful.
A novel dentin bond strength measurement technique using a composite disk in diametral compression.
Huang, Shih-Hao; Lin, Lian-Shan; Rudney, Joel; Jones, Rob; Aparicio, Conrado; Lin, Chun-Pin; Fok, Alex
2012-04-01
New methods are needed that can predict the clinical failure of dental restorations that primarily rely on dentin bonding. Existing methods have shortcomings, e.g. severe deviation in the actual stress distribution from theory and a large standard deviation in the measured bond strength. We introduce here a novel test specimen by examining an endodontic model for dentin bonding. Specifically, we evaluated the feasibility of using the modified Brazilian disk test to measure the post-dentin interfacial bond strength. Four groups of resin composite disks which contained a slice of dentin with or without an intracanal post in the center were tested under diametral compression until fracture. Advanced nondestructive examination and imaging techniques in the form of acoustic emission (AE) and digital image correlation (DIC) were used innovatively to capture the fracture process in real time. DIC showed strain concentration first appearing at one of the lateral sides of the post-dentin interface. The appearance of the interfacial strain concentration also coincided with the first AE signal detected. Utilizing both the experimental data and finite-element analysis, the bond/tensile strengths were calculated to be: 11.2 MPa (fiber posts), 12.9 MPa (metal posts), 8.9 MPa (direct resin fillings) and 82.6 MPa for dentin. We have thus established the feasibility of using the composite disk in diametral compression to measure the bond strength between intracanal posts and dentin. The new method has the advantages of simpler specimen preparation, no premature failure, more consistent failure mode and smaller variations in the calculated bond strength. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Need to Identify Parameters of Concrete in the Weakest Zone of the Industrial Floor
NASA Astrophysics Data System (ADS)
Stawiski, Bohdan; Radzik, Łukasz
2017-10-01
The ways in which industrial floors are exploited leads to the requirement for the highest strength of their upper zone. Physical phenomena occurring during the compaction and hardening of the concrete cause different strength distributions. In the top zone of industrial floors, the strength is significantly lower (over a dozen MPa) than the strength in the bottom zone (several dozen MPa). Standard tests of control samples do not detect this fact. Processes for the application and finishing of embedded mineral-aggregate hardeners (dry shakes) can be regarded as uncontrolled. The effects of the use of dry shakes are not evaluated. In combination with the phenomenon of bleeding, they often fail by delamination. This paper presents the results of industrial floor testing. The ultrasonic pulse velocity method with dry point contact transducers was used. The results show how upper layer strength was reduced, and how dry shakes application affected the strength of the floor. The strength distribution in hardened concrete, which delaminated from the rest of the floor was presented as well. The extension of compulsory control tests of concrete samples was proposed. In the authors’ opinion, particular attention should be paid to 3 centimetres of the upper layer.
Effect of interaction strength on robustness of controlling edge dynamics in complex networks
NASA Astrophysics Data System (ADS)
Pang, Shao-Peng; Hao, Fei
2018-05-01
Robustness plays a critical role in the controllability of complex networks to withstand failures and perturbations. Recent advances in the edge controllability show that the interaction strength among edges plays a more important role than network structure. Therefore, we focus on the effect of interaction strength on the robustness of edge controllability. Using three categories of all edges to quantify the robustness, we develop a universal framework to evaluate and analyze the robustness in complex networks with arbitrary structures and interaction strengths. Applying our framework to a large number of model and real-world networks, we find that the interaction strength is a dominant factor for the robustness in undirected networks. Meanwhile, the strongest robustness and the optimal edge controllability in undirected networks can be achieved simultaneously. Different from the case of undirected networks, the robustness in directed networks is determined jointly by the interaction strength and the network's degree distribution. Moreover, a stronger robustness is usually associated with a larger number of driver nodes required to maintain full control in directed networks. This prompts us to provide an optimization method by adjusting the interaction strength to optimize the robustness of edge controllability.
Evaluation of bolted connections in wood-plastic composites
NASA Astrophysics Data System (ADS)
Arnandha, Yudhi; Satyarno, Iman; Awaludin, Ali; Irawati, Inggar Septia; Ihsan, Muhamad; Wijanarko, Felyx Biondy; William, Mahdinur, Fardhani, Arfiati
2017-03-01
Wood-plastic composite (WPC) is a relatively new material that consists of sawdust and plastic polymer using the extrusion process. Due to its attributes such as low water content, low maintenance, UV durability and being fungi and termite resistant. Nowadays, WPC has already been produced in Indonesia using sawdust from local wood such as Albizia (Paraserianthes falcataria) and Teak (Tectona grandis). Moreover preliminary studies about the physical and mechanical WPC board from Albizia sawdust and HDPE plastic have been carried out. Based on these studies, WPC has a high shear strength around 25-30 MPa higher than its original wood shear strength. This paper was a part of the research in evaluating WPC as potential sheathing in a shear wall system. Since still little is known about connection behavior in WPC using Indonesian local wood, this study evaluated the connection for both of these two types of wood-plastic composite. WPC board from Albizia sawdust will be projected as shear wall sheathing and WPC stud from Teak sawdust projected to be shear wall frame. For this study, the embedding strength for both WPC was determined according to ASTM D 5764 standard, using two types of bolts (stainless bolt and standard bolt) with several diameters as variation (6 mm, 8 mm, 10 and 12 mm). Hence, dowel-bearing test under fastened condition conducted accordance to ASTM D5652, hereby the yield strength then compared with the prediction yield strength from European Yield Model (EYM). According to both single and double shear connection, it can be concluded that yield strength from the EYM method tended to under-predict the 5% diameter offset yield than the actual yield strength from the test. The yield strength itself increase with the increase of bolt diameter. For single shear connection, the highest yield strength was 12 mm standard bolt around 9732 N, slightly higher than stainless bolt around 9393 N. Whereby for double shear connection, the highest yield strength was 12 mm standard bolt around 12009 N, slightly higher than stainless bolt around 12009 N. Using statistical approach ANOVA, the different type of bolt between stainless bolt and standard bolt gave an insignificant result. Both type of bolt can be used as structural connection, moreover it was recommended using a stainless bolt for outdoor purpose to reduce corrosion.
Quantifying Bone–relevant Activity and its Relation to Bone Strength in Girls
Farr, Joshua N.; Lee, Vinson R.; Blew, Robert M.; Lohman, Timothy G.; Going, Scott B.
2011-01-01
Physical activity (PA) is critical for maximizing bone development during growth. However, there is no consensus on how well existing PA measurement tools predict bone strength. PURPOSE Compare four methods of quantifying physical activity (PA) (pedometer, 3-day physical activity recall (3DPAR), bone-specific physical activity questionnaire (BPAQ), and past year physical activity questionnaire (PYPAQ)), in young girls and evaluate their ability to predict indices of bone strength. METHODS 329 girls aged 8–13 years completed a pedometer assessment, the 3DPAR, the BPAQ, and a modified PYPAQ. Peripheral quantitative computed tomography (pQCT) was used to assess bone strength index (BSI) at metaphyseal (4% distal femur and tibia) sites and strength-strain index (SSI) at diaphyseal (femur = 20%, tibia = 66%) sites of the non-dominant leg. Correlations and hierarchical multiple regression were used to assess relationships among PA measures and indices of bone strength. RESULTS After adjustment for maturity, correlations between PA measures and indices of bone strength were positive, although low (r = 0.01–0.20). Regression models that included covariates (maturity, body mass, leg length, and ethnicity) and PA variables showed that PYPAQ score was significantly (P < 0.05) associated with BSI and SSI at all sites and explained more variance in BSI and SSI than any other PA measure. Pedometer steps were significantly (P < 0.05) associated with metaphyseal femur and tibia BSI and 3DPAR score was significantly (P < 0.05) associated with metaphyseal femur BSI. BPAQ score was not significantly (P > 0.05) associated with BSI or SSI at any sites. CONCLUSION A modified PYPAQ that accounts for the duration, frequency, and load of PA predicted indices of bone strength better than other PA measures. PMID:20631644
Eliasson, Sigfus Thor; Dahl, Jon E.
2017-01-01
Abstract Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer’s instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly (p < 0.001) tensile strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength (p < 0.001). Conclusions: Application of freshly made silane and a thin bonding layer, rendered higher tensile bond strength. Not curing the adhesive before composite placement increased the tensile bond strength. PMID:28642928
Dynamic Breaking Tests of Airplane Parts
NASA Technical Reports Server (NTRS)
Hertel, Heinrich
1933-01-01
The static stresses of airplane parts, the magnitude of which can be determined with the aid of static load assumptions, are mostly superposed by dynamic stresses, the magnitude of which has been but little explored. The object of the present investigation is to show how the strength of airplane parts can best be tested with respect to dynamic stresses with and without superposed static loading, and to what extent the dynamic strength of the parts depends on their structural design. Experimental apparatus and evaluation methods were developed and tried for the execution of vibration-strength tests with entire structural parts both with and without superposed static loading. Altogether ten metal spars and spar pieces and two wooden spars were subjected to vibration breaking tests.
NASA Astrophysics Data System (ADS)
Song, Won-Seok; Kim, Seung-Gyu; Kim, Young-Cheon; Kwon, Dongil
2015-03-01
In this paper we propose a novel method, spherical indentation, for evaluation of the plastic properties of combined structures. Three-dimensional (3D) printed products, for example gradient metal alloys consisting of different kinds of material, contain interfaces that can act as weak points and threaten the mechanical reliability of products. Combined structures containing an interface between Cu alloy and Ag were prepared for testing. Samples were heat-treated at 100°C and 200°C for 3 h to optimize processing conditions. The indentation tensile properties of the samples were estimated by analyzing multiple loading-unloading curves obtained by use of the representative stress and strain method. A continuous increase in both yield strength and tensile strength was observed for the Cu alloy and the Cu/Ag interface after heat treatment at up to 200°C, because of precipitation hardening. These experimental results show that mechanical characterization of combined structures by spherical indentation is highly useful on the nano and micro scales.
Oscillator strengths and branching fractions of 4d75p-4d75s Rh II transitions
NASA Astrophysics Data System (ADS)
Bouazza, Safa
2017-01-01
This work reports semi-empirical determination of oscillator strengths, transition probabilities and branching fractions for Rh II 4d75p-4d75s transitions in a wide wavelength range. The angular coefficients of the transition matrix, beforehand obtained in pure SL coupling with help of Racah algebra are transformed into intermediate coupling using eigenvector amplitudes of these two configuration levels determined for this purpose; The transition integral was treated as free parameter in the least squares fit to experimental oscillator strength (gf) values found in literature. The extracted value: <4d75s|r1|4d75p> =2.7426 ± 0.0007 is slightly smaller than that computed by means of ab-initio method. Subsequently to oscillator strength evaluations, transition probabilities and branching fractions were deduced and compared to those obtained experimentally or through another approach like pseudo-relativistic Hartree-Fock model including core-polarization effects.
A new silica-infiltrated Y-TZP obtained by the sol-gel method.
Campos, T M B; Ramos, N C; Machado, J P B; Bottino, M A; Souza, R O A; Melo, R M
2016-05-01
The aim of this study was to evaluate silica infiltration into dental zirconia (VITA In-Ceram 2000 YZ, Vita Zahnfabrik) and its effects on zirconia's surface characteristics, structural homogeneity and bonding to a resin cement. Infiltration was performed by immersion of the pre-sintered zirconia specimens in silica sols for five days (ZIn). Negative (pure zirconia specimens, ZCon-) and positive controls (specimens kept in water for 5 days, ZCon+) were also performed. After sintering, the groups were evaluated by X-ray diffraction (XRD), grazing angle X-ray diffraction (DRXR), scanning electron microscopy (SEM), contact angle measurements, optical profilometry, biaxial flexural test and shear bonding test. Weibull analysis was used to determine the Weibull modulus (m) and characteristic strength (σ0) of all groups. There were no major changes in strength for the infiltrated group, and homogeneity (m) was also increased. A layer of ZrSiO4 was formed on the surface. The bond strength to resin cement was improved after zirconia infiltration, acid conditioning and the use of an MDP primer. The sol-gel method is an efficient and simple method to increase the homogeneity of zirconia. Infiltration also improved bonding to resin cement. The performance of a zirconia infiltrated by silica gel improved in at least two ways: structural homogeneity and bonding to resin cement. The infiltration is simple to perform and can be easily managed in a prosthesis laboratory. Copyright © 2016 Elsevier Ltd. All rights reserved.
Marion, Jeffrey L.; Dvorak, Robert G.; Manning, Robert E.
2008-01-01
Opportunities to view and interact with wildlife are often an important part of high quality recreational experiences. Such interactions frequently include wildlife feeding, resulting in food-conditioned behaviors that may cause harm to both wildlife and visitors. This study developed and applied efficient protocols for simultaneously evaluating wildlife feeding-related behaviors of visitors and related foraging behaviors of chipmunks along a trail in Zion National Park. Unobtrusive observation protocols permitted an evaluation of educational messages delivered, and documentation of wildlife success in obtaining human food and the strength of their food attraction behavior. Significant improvements were documented for some targeted visitor behaviors and human food available to chipmunks, with minor differences between treatments. Replication of these protocols as part of a long-term monitoring program can help protected area managers evaluate and improve the efficacy of their interventions and monitor the strength of food attraction behavior in wildlife.
Qualitative Analysis of Written Reflections during a Teaching Certificate Program
Castleberry, Ashley N.; Payakachat, Nalin; Ashby, Sarah; Nolen, Amanda; Carle, Martha; Neill, Kathryn K.
2016-01-01
Objective. To evaluate the success of a teaching certificate program by qualitatively evaluating the content and extent of participants’ reflections. Methods. Two investigators independently identified themes within midpoint and final reflection essays across six program years. Each essay was evaluated to determine the extent of reflection in prompted teaching-related topic areas (strengths, weaknesses, assessment, feedback). Results. Twenty-eight themes were identified within 132 essays. Common themes encompassed content delivery, student assessment, personal successes, and challenges encountered. Deep reflection was exhibited, with 48% of essays achieving the highest level of critical reflection. Extent of reflection trended higher from midpoint to final essays, with significant increases in the strengths and feedback areas. Conclusion. The teaching certificate program fostered critical reflection and self-reported positive behavior change in teaching, thus providing a high-quality professional development opportunity. Such programs should strongly consider emphasizing critical reflection through required reflective exercises at multiple points within program curricula. PMID:26941436
Evaluation of a water-soluble bioadhesive patch for photodynamic therapy of vulval lesions.
McCarron, Paul A; Donnelly, Ryan F; Zawislak, Agnieszka; Woolfson, A David; Price, John H; McClelland, Raymond
2005-04-11
An innovative bioadhesive patch intended primarily as a vulval drug delivery system and, specifically, as a means to deliver photosensitisers, or their prodrugs, for photodynamic purposes is described. The patch was formulated with a copolymer of methyl vinyl ether and maleic anhydride (PMVE/MA) as a bioadhesive matrix and poly(vinyl chloride) as a drug-impervious backing layer. Adhesive strength to neonate porcine skin, as a model substrate, was evaluated using peel and tensile testing measurements. Acceptabilities of non-drug loaded patches were appraised using human volunteers and visual-analogue scoring devices. An optimal formulation, with water uptake and peel strengths appropriate for vulval drug delivery, was cast from a 20% (w/w) PMVE/MA solution and adhered with a strength of approximately 1.7 Ncm(-2). Patient evaluation demonstrated comfort and firm attachment for up to 4h in mobile patients. Aminolevulinic acid, a commonly used photosensitiser, was formulated into the candidate formulation and applied to vulval intraepithelial neoplastic lesions. Fluorescence under ultraviolet illumination revealed protoporphyrin synthesis. The patch achieves the extended application times obligatory in topical photodynamic therapy of vulval lesions, thereby contributing to potential methods for the eradication of neoplastic lesions in the lower female reproductive tract.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breder, K.; Tennery, V.J.
1994-09-01
Two monolithic silicon carbides, NT230 siliconized SiC from Norton Saint Gobain and sintered {beta}-SiC from Coors, and a silicon carbide particulate reinforced alumina ceramic composite from Lanxide, which all are candidate materials for pressurized heat exchangers in coal-fired power plants have been evaluated. The fast fracture flexure strength was measured as a function of temperature. All candidate materials retained a sufficient strength level up to 1400C. The susceptibility to slow crack growth (SCG) was evaluated by the dynamic fatigue method at 1100C and 1400C. None of the materials exhibited SCG at 1100C. At 1400C the siliconized SiC ceramic showed limitedmore » SCG and the composite ceramic exhibited creep damage when stressed to 50% of fast fracture strength at the intermediate and slow stressing rates. This prevented the evaluation of the SCG properties of this material at 1400C. Fractography supported the mechanical observations and with the exception of the specimens which exhibited creep damage, only the siliconized SiC showed a small SCG damage zone at long times at 1400C.« less
Cloaking data in optical networks
NASA Astrophysics Data System (ADS)
Klein, Avi; Shahal, Shir; Masri, Gilad; Duadi, Hamootal; Fridman, Moti
2018-01-01
Modern networks implement multi-layer encryption architecture to increase network security, stability, and robustness. We developed a new paradigm for optical encryption based on the strengths of optics over electronics and according to temporal optics principles. We developed a highly efficient all-optical encryption scheme for modern networks. Our temporal encryption scheme exploits the strength of optics over electronics. Specifically, we utilize dispersion together with nonlinear interaction for mixing neighboring bits with a private key. Our system encrypts the entire network traffic without any latency, encrypt the signal itself, exploit only one non- linear interaction, it is energetically efficient with low ecologic footprint, and can be added to current networks without replacing the hardware such as the lasers, the transmitters, the routers, the amplifiers or the receivers. Our method can replace current slow encryption methods or can be added to increase the security of existing systems. In this paper, we elaborate on the theoretical models of the system and how we evaluate the encryption strength with this numerical tools.
Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea
2017-01-01
Summary Background Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. Objective The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Methods Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. Results All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. Conclusions The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Level of evidence Ib. PMID:29264344
Kyaw Oo, May; Mandal, Uttam K; Chatterjee, Bappaditya
2017-02-01
High melting point polymeric carrier without plasticizer is unacceptable for solid dispersion (SD) by melting method. Combined polymer-plasticizer carrier significantly affects drug solubility and tableting property of SD. To evaluate and optimize the combined effect of a binary carrier consisting PVP K30 and poloxamer 188, on nisoldipine solubility and tensile strength of amorphous SD compact (SD compact ) by experimental design. SD of nisoldpine (SD nisol ) was prepared by melt mixing with different PVP K30 and poloxamer amount. A 3 2 factorial design was employed using nisoldipine solubility and tensile strength of SD compact as response variables. Statistical optimization by design expert software, and SD nisol characterization using ATR FTIR, DSC and microscopy were done. PVP K30:poloxamer, at a ratio of 3.73:6.63, was selected as the optimized combination of binary polymeric carrier resulting nisoldipine solubility of 115 μg/mL and tensile strength of 1.19 N/m 2 . PVP K30 had significant positive effect on both responses. Increase in poloxamer concentration after a certain level decreased nisoldipine solubility and tensile strength of SD compact . An optimized PVP K30-poloxamer binary composition for SD carrier was developed. Tensile strength of SD compact can be considered as a response for experimental design to optimize SD.
The relationships of waist and mid-thigh circumference with performance of college golfers
Son, Seungbum; Han, Kunho; So, Wi-Young
2016-01-01
[Purpose] Our aim was to evaluate the relationships between waist and mid-thigh circumference, used as proxy measures of trunk and lower limb strengths, respectively, and selected parameters of driver and putting performance in Korean college golfers. [Subjects and Methods] The participants were 103 college golfers (81 male, 20 to 27 years old). Measurements of body composition, waist and mid-thigh circumference, and grip strength, as well as assessment of golf performance, including driver distance, driver swing speed, putting accuracy, and putting consistency, were performed at the golf performance laboratory at Konkuk University in Chungju-si, Republic of Korea. Average round score was obtained from 10 rounds of golf completed during the study period. The relationships between strength measures and golf performance were evaluated by partial correlation analysis, with adjustment for age, golf experience, and body mass index. [Results] Waist circumference did not correlate with any of the performance variables in both males and females. Mid-thigh circumference correlated with putting consistency (r = 0.364) in males and with putting consistency (r = 0.490) and accuracy (r = 0.547) in females. No other significant correlations between waist and mid-thigh circumference and golf performance were identified. [Conclusion] Lower limb strength may be an important component of putting performance. Further studies are needed to fully characterize the contributions of trunk strength to performance. PMID:27134346
Hashmi, Syed W.; Rao, Yogesh; Garg, Akanksha
2015-01-01
Background Dental casting alloys play a prominent role in the restoration of the partial dentition. Casting alloys have to survive long term in the mouth and also have the combination of structure, molecules, wear resistance and biologic compatibility. According to ADA system casting alloys were divided into three groups (wt%); high noble, Noble and predominantly base metal alloys. Aim To evaluate the mechanical properties such as tensile strength and surface roughness of the new and recast base metal (nickel-chromium) alloys. Materials and Methods Recasting of the base metal alloys derived from sprue and button, to make it reusable has been done. A total of 200 test specimens were fabricated using specially fabricated jig of metal and divided into two groups- 100 specimens of new alloy and 100 specimens of recast alloys, which were tested for tensile strength on universal testing machine and surface roughness on surface roughness tester. Results Tensile strength of new alloy showed no statistically significant difference (p-value>0.05) from recast alloy whereas new alloy had statistically significant surface roughness (Maximum and Average surface roughness) difference (p-value<0.01) as compared to recast alloy. Conclusion Within the limitations of the study it is concluded that the tensile strength will not be affected by recasting of nickel-chromium alloy whereas surface roughness increases markedly. PMID:26393194
NASA Astrophysics Data System (ADS)
Murakami, Hiroki; Watanabe, Tsuneo; Fukuoka, Daisuke; Terabayashi, Nobuo; Hara, Takeshi; Muramatsu, Chisako; Fujita, Hiroshi
2016-04-01
The word "Locomotive syndrome" has been proposed to describe the state of requiring care by musculoskeletal disorders and its high-risk condition. Reduction of the knee extension strength is cited as one of the risk factors, and the accurate measurement of the strength is needed for the evaluation. The measurement of knee extension strength using a dynamometer is one of the most direct and quantitative methods. This study aims to develop a system for measuring the knee extension strength using the ultrasound images of the rectus femoris muscles obtained with non-invasive ultrasonic diagnostic equipment. First, we extract the muscle area from the ultrasound images and determine the image features, such as the thickness of the muscle. We combine these features and physical features, such as the patient's height, and build a regression model of the knee extension strength from training data. We have developed a system for estimating the knee extension strength by applying the regression model to the features obtained from test data. Using the test data of 168 cases, correlation coefficient value between the measured values and estimated values was 0.82. This result suggests that this system can estimate knee extension strength with high accuracy.
Owens, Douglas K; Lohr, Kathleen N; Atkins, David; Treadwell, Jonathan R; Reston, James T; Bass, Eric B; Chang, Stephanie; Helfand, Mark
2010-05-01
To establish guidance on grading strength of evidence for the Evidence-based Practice Center (EPC) program of the U.S. Agency for Healthcare Research and Quality. Authors reviewed authoritative systems for grading strength of evidence, identified domains and methods that should be considered when grading bodies of evidence in systematic reviews, considered public comments on an earlier draft, and discussed the approach with representatives of the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) working group. The EPC approach is conceptually similar to the GRADE system of evidence rating; it requires assessment of four domains: risk of bias, consistency, directness, and precision. Additional domains to be used when appropriate include dose-response association, presence of confounders that would diminish an observed effect, strength of association, and publication bias. Strength of evidence receives a single grade: high, moderate, low, or insufficient. We give definitions, examples, mechanisms for scoring domains, and an approach for assigning strength of evidence. EPCs should grade strength of evidence separately for each major outcome and, for comparative effectiveness reviews, all major comparisons. We will collaborate with the GRADE group to address ongoing challenges in assessing the strength of evidence.
Seuba, Jordi; Deville, Sylvain; Guizard, Christian; Stevenson, Adam J
2016-01-01
Macroporous ceramics exhibit an intrinsic strength variability caused by the random distribution of defects in their structure. However, the precise role of microstructural features, other than pore volume, on reliability is still unknown. Here, we analyze the applicability of the Weibull analysis to unidirectional macroporous yttria-stabilized-zirconia (YSZ) prepared by ice-templating. First, we performed crush tests on samples with controlled microstructural features with the loading direction parallel to the porosity. The compressive strength data were fitted using two different fitting techniques, ordinary least squares and Bayesian Markov Chain Monte Carlo, to evaluate whether Weibull statistics are an adequate descriptor of the strength distribution. The statistical descriptors indicated that the strength data are well described by the Weibull statistical approach, for both fitting methods used. Furthermore, we assess the effect of different microstructural features (volume, size, densification of the walls, and morphology) on Weibull modulus and strength. We found that the key microstructural parameter controlling reliability is wall thickness. In contrast, pore volume is the main parameter controlling the strength. The highest Weibull modulus ([Formula: see text]) and mean strength (198.2 MPa) were obtained for the samples with the smallest and narrowest wall thickness distribution (3.1 [Formula: see text]m) and lower pore volume (54.5%).
NASA Astrophysics Data System (ADS)
Seuba, Jordi; Deville, Sylvain; Guizard, Christian; Stevenson, Adam J.
2016-01-01
Macroporous ceramics exhibit an intrinsic strength variability caused by the random distribution of defects in their structure. However, the precise role of microstructural features, other than pore volume, on reliability is still unknown. Here, we analyze the applicability of the Weibull analysis to unidirectional macroporous yttria-stabilized-zirconia (YSZ) prepared by ice-templating. First, we performed crush tests on samples with controlled microstructural features with the loading direction parallel to the porosity. The compressive strength data were fitted using two different fitting techniques, ordinary least squares and Bayesian Markov Chain Monte Carlo, to evaluate whether Weibull statistics are an adequate descriptor of the strength distribution. The statistical descriptors indicated that the strength data are well described by the Weibull statistical approach, for both fitting methods used. Furthermore, we assess the effect of different microstructural features (volume, size, densification of the walls, and morphology) on Weibull modulus and strength. We found that the key microstructural parameter controlling reliability is wall thickness. In contrast, pore volume is the main parameter controlling the strength. The highest Weibull modulus (?) and mean strength (198.2 MPa) were obtained for the samples with the smallest and narrowest wall thickness distribution (3.1 ?m) and lower pore volume (54.5%).
Preliminary study of tin slag concrete mixture
NASA Astrophysics Data System (ADS)
Hashim, Mohd Jamil; Mansor, Ishak; Pauzi Ismail, Mohamad; Sani, Suhairy; Azmi, Azhar; Sayuti, Shaharudin; Zaidi Ibrahim, Mohd; Adli Anuar, Abul; Rahim, Abdul Adha Abdul
2018-01-01
The study focuses on practices to facilitate tin smelting industry to reduce radioactive waste product (Tin Slag) by diluting its radioactivity to a safe level and turning it to a safer infrastructural building product. In the process the concrete mix which include Portland cement, sand, tin slag, water and plasticizer are used to produce interlocking brick pavements, piles and other infrastructural products. The mixing method follows DOE (UK) standard method of mixing targeted at in selected compressive strength suitable for its function and durability. A batching machine is used in the mixing and six test cubes are produced for the test. The testing equipment used are a compressional machine, ultrasonic measurement and a Geiger Muller counter to evaluate of the concrete mix to find the lowest emission of radiation surface dose without compromising the strength of concrete mix. The result obtained indicated the radioactivity of tin slag in the mixing process has reduced to background level that is 0.5μSv/h while the strength and workability of the concrete has not been severely affected. In conclusion, the concrete mix with tin slag has shown the potential it can be turned into a safe beneficial infrastructural product with good strength.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M
2012-01-01
A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.
Keum, Eun-Cheol
2013-01-01
PURPOSE This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive cementation. MATERIALS AND METHODS Forty implant fixture analogues and abutments were embedded in resin blocks. Forty cast crowns were fabricated and divided into 4 groups each containing 10 implants. Group A was cemented directly with the definitive cement (Cem-Implant). The remainder were cemented with provisional cement (Temp-Bond NE), and classified according to the method for cleaning the abutments. Group B used a plastic curette and wet gauze, Group C used a rubber cup and pumice, and Group D used an airborne particle abrasion technique. The abutments were observed using a stereomicroscope after removing the provisional cement. The tensile bond strength was measured after the definitive cementation. Statistical analysis was performed using one-way analysis of variance test (α=.05). RESULTS Group B clearly showed provisional cement remaining, whereas the other groups showed almost no cement. Groups A and B showed a relatively smooth surface. More roughness was observed in Group C, and apparent roughness was noted in Group D. The tensile bond strength tests revealed Group D to have significantly the highest tensile bond strength followed in order by Groups C, A and B. CONCLUSION A plastic curette and wet gauze alone cannot effectively remove the residual provisional cement on the abutment. The definitive retention increased when the abutments were treated with rubber cup/pumice or airborne particle abraded to remove the provisional cement. PMID:24049563
NASA Technical Reports Server (NTRS)
1985-01-01
Advanced testing of structural materials was developed by Lewis Research Center and Langley Research Center working with the American Society for Testing and Materials (ASTM). Under contract, Aluminum Company of America (Alcoa) conducted a study for evaluating stress corrosion cracking, and recommended the "breaking load" method which determines fracture strengths as well as measuring environmental degradation. Alcoa and Langley plan to submit the procedure to ASTM as a new testing method.
The influence of the compression interface on the failure behavior and size effect of concrete
NASA Astrophysics Data System (ADS)
Kampmann, Raphael
The failure behavior of concrete materials is not completely understood because conventional test methods fail to assess the material response independent of the sample size and shape. To study the influence of strength and strain affecting test conditions, four typical concrete sample types were experimentally evaluated in uniaxial compression and analyzed for strength, deformational behavior, crack initiation/propagation, and fracture patterns under varying boundary conditions. Both low friction and conventional compression interfaces were assessed. High-speed video technology was used to monitor macrocracking. Inferential data analysis proved reliably lower strength results for reduced surface friction at the compression interfaces, regardless of sample shape. Reciprocal comparisons revealed statistically significant strength differences between most sample shapes. Crack initiation and propagation was found to differ for dissimilar compression interfaces. The principal stress and strain distributions were analyzed, and the strain domain was found to resemble the experimental results, whereas the stress analysis failed to explain failure for reduced end confinement. Neither stresses nor strains indicated strength reductions due to reduced friction, and therefore, buckling effects were considered. The high-speed video analysis revealed localize buckling phenomena, regardless of end confinement. Slender elements were the result of low friction, and stocky fragments developed under conventional confinement. The critical buckling load increased accordingly. The research showed that current test methods do not reflect the "true'' compressive strength and that concrete failure is strain driven. Ultimate collapse results from buckling preceded by unstable cracking.
Mechanical and bond strength properties of light-cured and chemically cured glass ionomer cements.
McCarthy, M F; Hondrum, S O
1994-02-01
The purpose of this study was to evaluate the mechanical and bond strength properties of a commercially available light-cured glass ionomer cement and of a chemically cured glass ionomer cement. Sixty recently extracted human molars were randomly divided into six equal groups, and the bond strengths of the two cement types were evaluated at 1 hour, 24 hours, and 7 days. Stainless steel lingual buttons were bonded to prepared enamel surfaces, and the samples were placed in a water bath at 37 degrees C until testing. The shear bond strength of each sample was determined with a universal testing instrument. The mechanical strength properties of the two cements were then evaluated. The transverse flexural strength, compressive strength, rigidity, and diametral tensile strength were tested for each cement at 1 hour, 24 hours, and 7 days. The results of the mechanical property strength tests were then compared with the results of the bond strength tests.(ABSTRACT TRUNCATED AT 250 WORDS)
Hall, William; Smith, Neale; Mitton, Craig; Urquhart, Bonnie; Bryan, Stirling
2018-01-01
Background: In order to meet the challenges presented by increasing demand and scarcity of resources, healthcare organizations are faced with difficult decisions related to resource allocation. Tools to facilitate evaluation and improvement of these processes could enable greater transparency and more optimal distribution of resources. Methods: The Resource Allocation Performance Assessment Tool (RAPAT) was implemented in a healthcare organization in British Columbia, Canada. Recommendations for improvement were delivered, and a follow up evaluation exercise was conducted to assess the trajectory of the organization’s priority setting and resource allocation (PSRA) process 2 years post the original evaluation. Results: Implementation of RAPAT in the pilot organization identified strengths and weaknesses of the organization’s PSRA process at the time of the original evaluation. Strengths included the use of criteria and evidence, an ability to reallocate resources, and the involvement of frontline staff in the process. Weaknesses included training, communication, and lack of program budgeting. Although the follow up revealed a regression from a more formal PSRA process, a legacy of explicit resource allocation was reported to be providing ongoing benefit for the organization. Conclusion: While past studies have taken a cross-sectional approach, this paper introduces the first longitudinal evaluation of PSRA in a healthcare organization. By including the strengths, weaknesses, and evolution of one organization’s journey, the authors’ intend that this paper will assist other healthcare leaders in meeting the challenges of allocating scarce resources. PMID:29626400
Miciak, Jeremy; Fletcher, Jack M.; Stuebing, Karla; Vaughn, Sharon; Tolar, Tammy D.
2014-01-01
Purpose Few empirical investigations have evaluated LD identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability and validity of two proposed PSW methods: the concordance/discordance method (C/DM) and cross battery assessment (XBA) method. Methods Cognitive assessment data for 139 adolescents demonstrating inadequate response to intervention was utilized to empirically classify participants as meeting or not meeting PSW LD identification criteria using the two approaches, permitting an analysis of: (1) LD identification rates; (2) agreement between methods; and (3) external validity. Results LD identification rates varied between the two methods depending upon the cut point for low achievement, with low agreement for LD identification decisions. Comparisons of groups that met and did not meet LD identification criteria on external academic variables were largely null, raising questions of external validity. Conclusions This study found low agreement and little evidence of validity for LD identification decisions based on PSW methods. An alternative may be to use multiple measures of academic achievement to guide intervention. PMID:24274155
Gunnarsson, U; Johansson, M; Strigård, K
2011-08-01
The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit. Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength. One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004. Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.
Drumond, Nélio; Stegemann, Sven
2018-06-01
Predicting the potential for unintended adhesion of solid oral dosage forms (SODF) to mucosal tissue is an important aspect that should be considered during drug product development. Previous investigations into low strength mucoadhesion based on particle interactions methods provided evidence that rheological measurements could be used to obtain valid predictions for the development of SODF coatings that can be safely swallowed. The aim of this second work was to estimate the low mucoadhesive strength properties of different polymers using in vitro methods based on mechanical forces and to identify which methods are more precise when measuring reduced mucoadhesion. Another aim was to compare the obtained results to the ones achieved with in vitro particle interaction methods in order to evaluate which methodology can provide stronger predictions. The combined results correlate between particle interaction methods and mechanical force measurements. The polyethylene glycol grades (PEG) and carnauba wax showed the lowest adhesive potential and are predicted to support safe swallowing. Hydroxypropyl methylcellulose (HPMC) along with high molecular grades of polyvinylpyrrolidone (PVP) and polyvinyl alcohol (PVA) exhibited strong in vitro mucoadhesive strength. The combination of rheological and force tensiometer measurements should be considered when assessing the reduced mucoadhesion of polymer coatings to support safe swallowing of SODF. Copyright © 2018 Elsevier B.V. All rights reserved.
Maximum Power Training and Plyometrics for Cross-Country Running.
ERIC Educational Resources Information Center
Ebben, William P.
2001-01-01
Provides a rationale for maximum power training and plyometrics as conditioning strategies for cross-country runners, examining: an evaluation of training methods (strength training and maximum power training and plyometrics); biomechanic and velocity specificity (role in preventing injury); and practical application of maximum power training and…
QUANTITATIVE DECISION TOOLS AND MANAGEMENT DEVELOPMENT PROGRAMS.
ERIC Educational Resources Information Center
BYARS, LLOYD L.; NUNN, GEOFFREY E.
THIS ARTICLE OUTLINED THE CURRENT STATUS OF QUANTITATIVE METHODS AND OPERATIONS RESEARCH (OR), SKETCHED THE STRENGTHS OF TRAINING EFFORTS AND ISOLATED WEAKNESSES, AND FORMULATED WORKABLE CRITERIA FOR EVALUATING SUCCESS OF OPERATIONS RESEARCH TRAINING PROGRAMS. A SURVEY OF 105 COMPANIES REVEALED THAT PERT, INVENTORY CONTROL THEORY AND LINEAR…
Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar
2017-05-01
OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.
Bahnasi, Faisal I; Abd-Rahman, Aida Na; Abu-Hassan, Mohame I
2013-10-01
1) to assess different methods of recycling orthodontic brackets, 2) to evaluate Shear Bond Strength (SBS) of (a) new, (b) recycled and (c) repeated recycled stainless steel brackets (i) with and (ii) without bracket base primer. A total of 180 extracted human premolar teeth and 180 premolar stainless steel brackets were used. One hundred teeth and 100 brackets were divided into five groups of 20-teeth each. Four methods of recycling orthodontic brackets were used in each of the first four groups while the last one (group V) was used as the control. Groups (I-V) were subjected to shear force within half an hour until the brackets debond. SBS was measured and the method showing the highest SBS was selected. A New group (VI) was recycled twice with the selected method. Six subgroups (1-6) were established; the primer was applied for three sub-groups, and the composite was applied for all brackets. Brackets were subjected to the same shear force, and SBS was measured for all sub-groups. There was a significant difference between the mean SBS of the sandblasting method and the means of SBS of each of the other three methods. There was however, no significant difference between the mean SBS of the new bracket and the mean SBS of recycled bracket using sandblasting. The mean SBS of all sub-groups were more than that recommended by Reynolds (17) in 1975. Brackets with primer showed slightly higher SBS compared to those of brackets without bonding agent. To decrease cost, sandblasted recycled orthodontic brackets can be used as an alternative to new brackets. It is recommended to apply a bonding agent on the bracket base to provide greater bond strength. Key words:Recycled bracket, shear bond strength, sandblasting, stainless steel orthodontic bracket.
NASA Astrophysics Data System (ADS)
Lawrenz, Frances; McCreath, Heather
Qualitative and quantitative evaluation procedures were used to compare two physical-science teacher inservice training programs. The two programs followed the master teacher training model espoused by NSF but used different types of master teachers and types of activities. The two evaluation procedures produced different results and together they provided a much clearer picture of the strengths and weaknesses of the two programs. Using only one approach or the other would have substantially altered the conclusions.
NASA Astrophysics Data System (ADS)
Wu, Yi; Wang, Chunlin; Sun, Hao; Rong, Mingzhe; Murphy, Anthony Bruce; Li, Tianwei; Zhong, Jianying; Chen, Zhexin; Yang, Fei; Niu, Chunpin
2017-09-01
C5-PFK (C5-perfluoroketone, C5F10O) is under wide consideration as an environmentally-friendly alternative gas to SF6 in high-voltage applications, because of its superior insulation performance. The aim of this work is to study theoretically the arc extinguishing performance and electric strength of C5-PFK. The arc extinguishing performance of C5-PFK was evaluated by analyzing and comparing the thermophysical properties of C5-PFK, SF6, CF4, CO2 and N2 plasmas. It was difficult to obtain the species formed in C5-PFK plasmas because of the complex C5-PFK molecular decomposition process. In this work, the decomposition process of C5-PFK and the related species were analyzed by the bond energy analysis method. For the species for which parameters such as the partition function and the enthalpy of formation were not available, computational chemistry methods were used to obtain the required data. The collision integrals were calculated using the phenomenological potential model. Using these results, the local thermodynamic equilibrium composition at temperatures from 300 to 30 000 K at 1-10 atm of pure C5-PFK was calculated by the method of minimization of the Gibbs free energy, and the corresponding transport coefficients were calculated by Chapman-Enskog method. Through the comparison of the thermophysical properties, it was found that C5-PFK had similar characteristics to SF6, with large peaks in specific heat below 4500 K, indicating potentially good thermal interruption capability. However, the specific heat peak at 7000 K corresponding to CO decomposition may detract from the thermal interruption capability. Specific heat peaks at higher temperatures are associated with the breaking of double or triple bonds, and should be avoided if possible in the new alternative gases. The electric strength of C5-PFK was assessed using the molecular electrostatic potential, which can be accurately calculated or measured, and gives strong insights into important characteristics of the molecule. Based on the analysis of the molecular surface electrostatic potential and electric strength of C5-PFK, SF6, CF4, CO2, and N2, it is found that the positive potential area of the molecular surface has a strong correlation with the electric strength and is expected to be one of the predictors of electric strength. To verify this phenomenon, 36 kinds of particles were used for the correlation analysis. The correlation coefficient between the positive potential area and electric strength is up to 0.9 which means strong correlation.
Flexural Properties of PLA Components Under Various Test Condition Manufactured by 3D Printer
NASA Astrophysics Data System (ADS)
Jaya Christiyan, K. G.; Chandrasekhar, U.; Venkateswarlu, K.
2018-06-01
Rapid Prototyping (RP) technologies have emerged as a fabrication method to obtain engineering components in the resent past. Desktop 3D printing, also referred as an additive layer manufacturing technology is a powerful method of RP technique that can fabricate 3 dimensional engineering components. In this method, 3D digital data is converted into real product. In the present investigation, Polylactic Acid (PLA) was considered as a starting material. Flexural strength of PLA material was evaluated using 3-point bend test, as per ASTM D790 standard. Specimens with flat (0°) and vertical (90°) orientation were considered. Moreover, layer thicknesses of 0.2, 0.25, and 0.3 mm were considered. To fabricate these specimens, printing speed of 38 and 52 mm/s was maintained. Nozzle diameter of 0.4 mm with 40 % of infill density were used. Based on the experimental results, it was observed that 0° orientation, 38 mm/s printing speed, and 0.2 mm layer thickness resulted maximum flexural strength, as compared to all other specimens. The improved flexural strength was due to the lower layer thickness (0.2 mm) specimens, as compared with other specimens made of 0.25 and 0.30 mm layer thicknesses. It was concluded that flexural strength properties were greatly influenced by lower the layer thickness, printing speed, and orientation.
Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets.
Sohrabi, Aydin; Jafari, Sanaz; Kimyai, Soodabeh; Rikhtehgaran, Sahand
2016-10-01
Since there is no standard method for rebonding loose ceramic brackets, the aim of this study was to evaluate the possibility of using Er,Cr:YSGG laser to eliminate the remaining composite materials from the base of ceramic brackets and to compare the bond strength of rebonded brackets with the new ones. Sixty-two extracted human premolars were mounted in acrylic cylinders. Thirty-one ceramic brackets were bonded, and shear bond strength was tested using Hounsfield testing machine. The remnants of the bonding material were removed from the bases of brackets using Er,Cr:YSGG laser. These brackets were rebonded to 31 fresh teeth and again shear bond strength was measured. Pattern of debonding was assessed in both cases under a stereomicroscope and graded according to ARI index. Data were analyzed with independent t-test and Fisher's exact test. Mean shear bond strength of the bond and rebond groups was 12.29 ± 5.46 and 10.58 ± 5.16 MPa, respectively. There were no significant differences between the two groups (p = 0.21). Pattern of bond failure was not statistically different between the two groups. Er,Cr:YSGG laser was effective in removing the remnants of bonding material from the base of ceramic brackets without any interference with the ceramic base itself, demonstrating that it might be a suitable method for rebonding ceramic brackets.
Fatigue Properties of the Ultra-High Strength Steel TM210A
Kang, Xia; Zhao, Gui-ping
2017-01-01
This paper presents the results of an experiment to investigate the high cycle fatigue properties of the ultra-high strength steel TM210A. A constant amplitude rotating bending fatigue experiment was performed at room temperature at stress ratio R = −1. In order to evaluate the notch effect, the fatigue experiment was carried out upon two sets of specimens, smooth and notched, respectively. In the experiment, the rotating bending fatigue life was tested using the group method, and the rotating bending fatigue limit was tested using the staircase method at 1 × 107 cycles. A double weighted least square method was then used to fit the stress-life (S–N) curve. The S–N curves of the two sets of specimens were obtained and the morphologies of the fractures of the two sets of specimens were observed with scanning electron microscopy (SEM). The results showed that the fatigue limit of the smooth specimen for rotating bending fatigue was 615 MPa; the ratio of the fatigue limit to tensile strength was 0.29, and the cracks initiated at the surface of the smooth specimen; while the fatigue limit of the notched specimen for rotating bending fatigue was 363 MPa, and the cracks initiated at the edge of the notch. The fatigue notch sensitivity index of the ultra-high strength maraging steel TM210A was 0.69. PMID:28891934
Yi, Seong; Rim, Dae-Cheol; Park, Seoung Woo; Murovic, Judith A; Lim, Jesse; Park, Jon
2015-06-01
In vertebrae with low bone mineral densities pull out strength is often poor, thus various substances have been used to fill screw holes before screw placement for corrective spine surgery. We performed biomechanical cadaveric studies to compare nonaugmented pedicle screws versus hydroxyapatite, calcium phosphate, or polymethylmethacrylate augmented pedicle screws for screw tightening torques and pull out strengths in spine procedures requiring bone screw insertion. Seven human cadaveric T10-L1 spines with 28 vertebral bodies were examined by x-ray to exclude bony abnormalities. Dual-energy x-ray absorptiometry scans evaluated bone mineral densities. Twenty of 28 vertebrae underwent ipsilateral fluoroscopic placement of 6-mm holes augmented with hydroxyapatite, calcium phosphate, or polymethylmethacrylate, followed by transpedicular screw placements. Controls were pedicle screw placements in the contralateral hemivertebrae without augmentation. All groups were evaluated for axial pull out strength using a biomechanical loading frame. Mean pedicle screw axial pull out strength compared with controls increased by 12.5% in hydroxyapatite augmented hemivertebrae (P = 0.600) and by 14.9% in calcium phosphate augmented hemivertebrae (P = 0.234), but the increase was not significant for either method. Pull out strength of polymethylmethacrylate versus hydroxyapatite augmented pedicle screws was 60.8% higher (P = 0.028). Hydroxyapatite and calcium phosphate augmentation in osteoporotic vertebrae showed a trend toward increased pedicle screw pull out strength versus controls. Pedicle screw pull out force of polymethylmethacrylate in the insertion stage was higher than that of hydroxyapatite. However, hydroxyapatite is likely a better clinical alternative to polymethylmethacrylate, as hydroxyapatite augmentation, unlike polymethylmethacrylate augmentation, stimulates bone growth and can be revised. Copyright © 2015 Elsevier Inc. All rights reserved.
de Figueiredo, Viviane Maria Gonçalves; Pereira, Sarina Maciel Braga; Bressiani, Eduardo; Valera, Márcia Carneiro; Bottino, Marco Antônio; Zhang, Yu; de Melo, Renata Marques
2017-01-01
Abstract Objective: This study evaluated the influence of porcelain (VM9, VITA Zahnfabrik, Germany) thickness on the flexural strength and crack propagation in bilayered zirconia systems (YZ, VITA Zahnfabrik, Germany). Material and Methods: Thirty zirconia bars (20.0x4.0x1.0 mm) and six zirconia blocks (12.0x7.5x1.2 mm) were prepared and veneered with porcelain with different thickness: 1 mm, 2 mm, or 3 mm. The bars of each experimental group (n=10) were subjected to four-point flexural strength testing. In each ceramic block, a Vickers indentation was created under a load of 10 kgf for 10 seconds, for the propagation of cracks. Results: The results of flexural strength were evaluated by One-way ANOVA and Tukey's test, with a significance level of 5%. The factor “thickness of the porcelain” was statistically significant (p=0.001) and the l-mm group presented the highest values of flexural strength. The cracks were predominant among the bending specimens with 1 and 2 mm of porcelain, and catastrophic failures were found in 50% of 3-mm-thick porcelain. After the indentation of blocks, the most severe defects were observed in blocks with 3-mm-thick porcelain. Conclusion: The smallest (1 mm) thickness of porcelain on the zirconia infrastructure presented higher values of flexural strength. Better resistance to defect propagation was observed near the porcelain/ zirconia interface for all groups. Higher flexural strength was found for a thinner porcelain layer in a bilayered zirconia system. The damage caused by a Vickers indentation near and far the interface with the zirconia shows that the stress profiles are different. PMID:29069155
Guo, Jing; Zhu, Jia; Liu, Hon-Guang; Zhu, Hong-Shui
2017-02-01
To evaluate the effect of bond strength between 3mol% yttrium-stabilized tetragonal zirconium polycrystal (3Y-TZP) zirconia framework after modified wet particle erosion and veneering porcelain. A total of 174 [8 mm× 8 mm× 3 mm (±0.02)] specimens were prepared and then randomly divided into different groups according to different particle size, sandblasting pressure, sandblasting time through conventional sandblasting (experimental groups); specimens in the control group were not sandblasted. The bond strength between 3Y-TZP zirconia framework and veneering porcelain was measured using a universal testing machine. Statistical analysis was performed using SPSS17.0 software package. The bond strength of specimens treated by two methods-conventional sandblasting and modified wet particle erosion under the same condition (150 μm, 0.6 MPa, 30 s) were acquired, while the surface was analyzed microscopically before the specimens were veneered with the veneering ceramic under scanning electronic microscope (SEM). The bond strength of conventional sandblasting group under the condition (110 μm, 0.4 MPa,30 s) was maximal, and significantly higher than the control group (P<0.05). The bond strength of modified wet particle erosion group was significantly higher than the conventional sandblasting group and control group (P<0.01); SEM showed that the surface of specimen with modified wet particle erosion was homogeneously rough; the surface specimen with conventional sandblasting was heterogeneously rough, some microcracks were seen in some areas. Sandblasting can slightly enhance the bond strength between 3Y-TZP zirconia framework and veneering porcelain, modified wet particle erosion is recommended for 3Y-TZP zirconia framework surface treatment.
Shi, Brendan Y; Diaz, Miguel; Belkoff, Stephen M; Srikumaran, Uma
2017-12-01
Obtaining strong fixation in low-density bone is increasingly critical in surgical repair of rotator cuff tears because of the aging population. To evaluate two new methods of improving pullout strength of transosseous rotator cuff repair in low-density bone, we analyzed the effects of 1) using 2-mm suture tape instead of no. 2 suture and 2) augmenting the lateral tunnel with cement. Eleven pairs of osteopenic or osteoporotic cadaveric humeri were identified by dual-energy x-ray absorptiometry. One bone tunnel and one suture were placed in the heads of 22 specimens. Five randomly selected pairs were repaired with no. 2 suture; the other six pairs were repaired with 2-mm suture tape. One side of each pair received lateral tunnel cement augmentation. Specimens were tested to suture pullout. Data were fitted to multivariate models that accounted for bone mineral density and other specimen characteristics. Two specimens were excluded because of knot-slipping during testing. Use of suture tape versus no. 2 suture conferred a 75-N increase (95% CI: 37, 113) in pullout strength (P<0.001). Cement augmentation conferred a 42-N improvement (95% CI: 10, 75; P=0.011). Other significant predictors of pullout strength were age, sex, and bone mineral density. We show two methods of improving the fixation strength of transosseous rotator cuff repairs in low-density bone: using 2-mm suture tape instead of no. 2 suture and augmenting the lateral tunnel with cement. These methods may improve the feasibility of transosseous repairs in an aging patient population. Copyright © 2017 Elsevier Ltd. All rights reserved.
Notched Strength Allowables and Inplane Shear Strength of AS4/VRM-34 Textile Laminates
NASA Technical Reports Server (NTRS)
Grenoble, Ray W.; Johnston, William M.
2013-01-01
Notched and unnotched strength allowables were developed for a textile composite to provide input data to analytical structural models based on the Pultruded Rod Stiffened Efficient Unitized Structure (PRSEUS) concept. Filled-hole tensile strength, filled-hole compressive strength, and inplane shear strength along stitch lines have been measured. The material system evaluated in this study is based on warp-knitted preforms of AS4 carbon fibers and VRM-34 epoxy resin, which have been processed via resin infusion and oven curing. All specimens were tested in as-fabricated (dry) condition. Filled-hole strengths were evaluated with and without through-thickness stitching. The effects of scaling on filled-hole tensile strength were evaluated by testing specimens in two widths, but with identical width / hole-diameter ratios. Inplane shear specimens were stitched in two configurations, and two specimen thicknesses were tested for each stitch configuration.
Advanced Technology Composite Fuselage-Structural Performance
NASA Technical Reports Server (NTRS)
Walker, T. H.; Minguet, P. J.; Flynn, B. W.; Carbery, D. J.; Swanson, G. D.; Ilcewicz, L. B.
1997-01-01
Boeing is studying the technologies associated with the application of composite materials to commercial transport fuselage structure under the NASA-sponsored contracts for Advanced Technology Composite Aircraft Structures (ATCAS) and Materials Development Omnibus Contract (MDOC). This report addresses the program activities related to structural performance of the selected concepts, including both the design development and subsequent detailed evaluation. Design criteria were developed to ensure compliance with regulatory requirements and typical company objectives. Accurate analysis methods were selected and/or developed where practical, and conservative approaches were used where significant approximations were necessary. Design sizing activities supported subsequent development by providing representative design configurations for structural evaluation and by identifying the critical performance issues. Significant program efforts were directed towards assessing structural performance predictive capability. The structural database collected to perform this assessment was intimately linked to the manufacturing scale-up activities to ensure inclusion of manufacturing-induced performance traits. Mechanical tests were conducted to support the development and critical evaluation of analysis methods addressing internal loads, stability, ultimate strength, attachment and splice strength, and damage tolerance. Unresolved aspects of these performance issues were identified as part of the assessments, providing direction for future development.
Nguyen, Trang T; Miller, Arthur; Orellana, Maria F
2011-07-01
(1) To quantitatively characterize human enamel porosity and surface area in vitro before and after etching for variable etching times; and (2) to evaluate shear bond strength after variable etching times. Specifically, our goal was to identify the presence of any correlation between enamel porosity and shear bond strength. Pore surface area, pore volume, and pore size of enamel from extracted human teeth were analyzed by Brunauer-Emmett-Teller (BET) gas adsorption before and after etching for 15, 30, and 60 seconds with 37% phosphoric acid. Orthodontic brackets were bonded with Transbond to the samples with variable etch times and were subsequently applied to a single-plane lap shear testing system. Pore volume and surface area increased after etching for 15 and 30 seconds. At 60 seconds, this increase was less pronounced. On the contrary, pore size appears to decrease after etching. No correlation was found between variable etching times and shear strength. Samples etched for 15, 30, and 60 seconds all demonstrated clinically viable shear strength values. The BET adsorption method could be a valuable tool in enhancing our understanding of enamel characteristics. Our findings indicate that distinct quantitative changes in enamel pore architecture are evident after etching. Further testing with a larger sample size would have to be carried out for more definitive conclusions to be made.
Wang, Zhi-Yu; Wang, Qing-Yuan; Liu, Yong-Jie
2015-01-01
Corrugated steel web with inherent high out-of-plane stiffness has a promising application in configuring large span highway bridge girders. Due to the irregularity of the configuration details, the local stress concentration poses a major fatigue problem for the welded flange plates of high strength low alloy structural steels. In this work, the methods of applying CFRP laminate and shot peening onto the surfaces of the tension flanges were employed with the purpose of improving the fatigue strength of such configuration details. The effectiveness of this method in the improvement of fatigue strength has been examined experimentally. Test results show that the shot peening significantly increases hardness and roughness in contrast to these without treatment. Also, it has beneficial effects on the fatigue strength enhancement when compared against the test data of the joints with CFRP strengthening. The stiffness degradation during the loading progress is compared with each treatment. Incorporating the stress acting on the constituent parts of the CFRP laminates, a discussion is made regarding the mechanism of the retrofit and related influencing factors such as corrosion and economic cost. This work could enhance the understanding of the CFRP and shot peening in repairing such welded details and shed light on the reinforcement design of welded joints between corrugated steel webs and flange plates. PMID:28793509
NASA Astrophysics Data System (ADS)
Long, Nicholas James
This thesis serves to develop a preliminary foundational methodology for evaluating the static complexity of future lunar oxygen production systems when extensive information is not yet available about the various systems under consideration. Evaluating static complexity, as part of a overall system complexity analysis, is an important consideration in ultimately selecting a process to be used in a lunar base. When system complexity is higher, there is generally an overall increase in risk which could impact the safety of astronauts and the economic performance of the mission. To evaluate static complexity in lunar oxygen production, static complexity is simplified and defined into its essential components. First, three essential dimensions of static complexity are investigated, including interconnective complexity, strength of connections, and complexity in variety. Then a set of methods is developed upon which to separately evaluate each dimension. Q-connectivity analysis is proposed as a means to evaluate interconnective complexity and strength of connections. The law of requisite variety originating from cybernetic theory is suggested to interpret complexity in variety. Secondly, a means to aggregate the results of each analysis is proposed to create holistic measurement for static complexity using the Single Multi-Attribute Ranking Technique (SMART). Each method of static complexity analysis and the aggregation technique is demonstrated using notional data for four lunar oxygen production processes.
Medina, L; Acosta-Pérez, E; Velez, C; Martínez, G; Rivera, M; Sardiñas, L; Pattatucci, A
2015-10-01
This article describes the use of Success Case Method (Brinkerhoff, 2003) to evaluate health promotion and public health training programs. The goal of the Office Community Research and Engagement (OCRE) of the Puerto Rico Clinical and Translational Research Consortium (PRCTRC) is to establish a stable and sustainable translational research capacity. Early efforts toward achieving this goal included sponsoring two independent research training programs. A description of the implementation of the five step Success Case Method is presented. Results reveal that SCM would deem both trainings as highly successful, based upon the overall impact of a low number of success cases. However, a traditional summative evaluation would consider this disappointing. Strengths of SCM are discussed. It was concluded that the Success Case Method is a useful and valuable evaluative method for measuring the success of health promotion and public health training initiatives and provides sufficient information for decision-making processes. Copyright © 2015 Elsevier Ltd. All rights reserved.
46 CFR 160.076-11 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following methods: (1) Method 5100, Strength and Elongation, Breaking of Woven Cloth; Grab Method, 160.076-25; (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, 160.076-25; (3) Method 5134, Strength of Cloth, Tearing; Tongue Method, 160.076-25. Underwriters Laboratories (UL) Underwriters...
Zhou, Ronggang; Chan, Alan H S
2017-01-01
In order to compare existing usability data to ideal goals or to that for other products, usability practitioners have tried to develop a framework for deriving an integrated metric. However, most current usability methods with this aim rely heavily on human judgment about the various attributes of a product, but often fail to take into account of the inherent uncertainties in these judgments in the evaluation process. This paper presents a universal method of usability evaluation by combining the analytic hierarchical process (AHP) and the fuzzy evaluation method. By integrating multiple sources of uncertain information during product usability evaluation, the method proposed here aims to derive an index that is structured hierarchically in terms of the three usability components of effectiveness, efficiency, and user satisfaction of a product. With consideration of the theoretical basis of fuzzy evaluation, a two-layer comprehensive evaluation index was first constructed. After the membership functions were determined by an expert panel, the evaluation appraisals were computed by using the fuzzy comprehensive evaluation technique model to characterize fuzzy human judgments. Then with the use of AHP, the weights of usability components were elicited from these experts. Compared to traditional usability evaluation methods, the major strength of the fuzzy method is that it captures the fuzziness and uncertainties in human judgments and provides an integrated framework that combines the vague judgments from multiple stages of a product evaluation process.
Ellmann, Stephan; Kammerer, Ferdinand; Brand, Michael; Allmendinger, Thomas; May, Matthias S; Uder, Michael; Lell, Michael M; Kramer, Manuel
2016-05-01
The aim of this study was to determine the dose reduction potential of iterative reconstruction (IR) algorithms in computed tomography angiography (CTA) of the circle of Willis using a novel method of evaluating the quality of radiation dose-reduced images. This study relied on ReconCT, a proprietary reconstruction software that allows simulating CT scans acquired with reduced radiation dose based on the raw data of true scans. To evaluate the performance of ReconCT in this regard, a phantom study was performed to compare the image noise of true and simulated scans within simulated vessels of a head phantom. That followed, 10 patients scheduled for CTA of the circle of Willis were scanned according to our institute's standard protocol (100 kV, 145 reference mAs). Subsequently, CTA images of these patients were reconstructed as either a full-dose weighted filtered back projection or with radiation dose reductions down to 10% of the full-dose level and Sinogram-Affirmed Iterative Reconstruction (SAFIRE) with either strength 3 or 5. Images were marked with arrows pointing on vessels of different sizes, and image pairs were presented to observers. Five readers assessed image quality with 2-alternative forced choice comparisons. In the phantom study, no significant differences were observed between the noise levels of simulated and true scans in filtered back projection, SAFIRE 3, and SAFIRE 5 reconstructions.The dose reduction potential for patient scans showed a strong dependence on IR strength as well as on the size of the vessel of interest. Thus, the potential radiation dose reductions ranged from 84.4% for the evaluation of great vessels reconstructed with SAFIRE 5 to 40.9% for the evaluation of small vessels reconstructed with SAFIRE 3. This study provides a novel image quality evaluation method based on 2-alternative forced choice comparisons. In CTA of the circle of Willis, higher IR strengths and greater vessel sizes allowed higher degrees of radiation dose reduction.
Toodehzaeim, Mohammad Hossein; Zandi, Hengameh; Meshkani, Hamidreza; Hosseinzadeh Firouzabadi, Azadeh
2018-03-01
Orthodontic appliances facilitate microbial plaque accumulation and increase the chance of white spot lesions. There is a need for new plaque control methods independent of patient's cooperation. The aim of this study was to determine the effects of incorporating copper oxide (CuO) nanoparticles on antimicrobial properties and bond strength of orthodontic adhesive. CuO nanoparticles were added to the composite transbond XT at concentrations of 0.01, 0.5 and 1 wt.%. To evaluate the antimicrobial properties of composites containing nanoparticles, the disk agar diffusion test was used. For this purpose, 10 discs from each concentration of nano-composites (totally 30 discs) and 10 discs from conventional composite (as the control group) were prepared. Then the diameter of streptococcus mutans growth inhibition around each disc was determined in blood agar medium. To evaluate the shear bond strength, with each concentration of nano-composites as well as the control group (conventional composite), 10 metal brackets were bonded to the human premolars and shear bond strength was determined using a universal testing machine. Nano-composites in all three concentrations showed significant antimicrobial effect compared to the control group ( p < 0.001). With increasing concentration of nanoparticles, antimicrobial effect showed an upward trend, although statistically was not significant. There was no significant difference between the shear bond strength of nano-composites compared to control group ( p = 0.695). Incorporating CuO nanoparticles into adhesive in all three studied concentrations added antimicrobial effects to the adhesive with no adverse effects on shear bond strength.
Kamble, Suresh S; Kandasamy, Baburajan; Thillaigovindan, Ranjani; Goyal, Nitin Kumar; Talukdar, Pratim; Seal, Mukut
2015-05-01
Newer dentin bonding agents were developed to improve the quality of composite restoration and to reduce time consumption in its application. The aim of the present study was to evaluate tensile bond strength of 6(th), 7(th) and 8(th) generation bonding agents by in vitro method. Selected 60 permanent teeth were assigned into 20 in each group (Group I: 6(th) generation bonding agent-Adper SE plus 3M ESPE, Group II: 7(th) generation bonding agent-G-Bond GC Corp Japan and Group III: 8(th) generation dentin adhesives-FuturaBond, DC, Voco, Germany). With high-speed diamond disc, coronal dentin was exposed, and selected dentin bonding agents were applied, followed by composite restoration. All samples were saved in saline for 24 h and tensile bond strength testing was done using a universal testing machine. The obtained data were tabulated and statistically analyzed using ANOVA test. The tensile bond strength readings for 6(th) generation bonding agent was 32.2465, for 7(th) generation was 31.6734, and for 8(th)-generation dentine bonding agent was 34.74431. The highest tensile bond strength was seen in 8(th) generation bonding agent compared to 6(th) and 7(th) generation bonding agents. From the present study it can be conclude that 8(th) generation dentine adhesive (Futura DC, Voco, Germany) resulted in highest tensile bond strength compared to 6(th) (Adper SE plus, 3M ESPE) and 7(th) generation (G-Bond) dentin bonding agents.
NASA Astrophysics Data System (ADS)
Heravi, Farzin; Bagheri, Hossein; Rangrazi, Abdolrasoul; Mojtaba Zebarjad, Seyed
2016-12-01
Caries and white spot lesions around orthodontic bands are well known occurrences in fixed orthodontic treatment. There are several methods to overcome these problems. One of these includes modification of the band cement with remineralizing agents such as casein phosphopeptide-amorphous calcium phosphate (CPP-ACP). However, it should be evaluated that the cement modification has no significant negative effects on the retentive strength of the cemented orthodontic bands. In a continuation of our previous studies on the effects of the addition of CPP-ACP on the mechanical properties of luting and lining glass ionomer cement (GIC), this study aimed to investigate the retentive strength of orthodontic bands cemented with CPP-ACP containing GIC. Sixty extracted human pre molars teeth were embedded in acrylic resin and randomly divided into two groups of 30 specimens. In group 1, bands were cemented to the tooth with a GIC. In group 2, CPP-ACP (1.56% w/w) was added to the GIC before cementation. The retentive strength of each groups was determined with a universal testing machine. Further, the amount of cement remaining on the tooth surface was evaluated under a stereomicroscope, and the adhesive remnant index (ARI) score was determined. Results of this study showed that there were no significant differences between the groups in retentive strength and ARI score. In conclusion, modification of GIC with 1.56% w/w CPP-ACP had no negative effects on the retentive strength of the bands so can be used during fixed orthodontic treatment.
Dynapenic Obesity and Prevalence of Type 2 Diabetes in Middle-Aged Japanese Men
Kawakami, Ryoko; Sawada, Susumu S.; Lee, I-Min; Matsushita, Munehiro; Gando, Yuko; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko; Blair, Steven N.
2015-01-01
Background The independent and combined associations of muscle strength and obesity on the prevalence of type 2 diabetes in Japanese men remain unclear. Methods Hand grip strength was cross-sectionally evaluated between 2011 and 2013 to assess muscle strength in 5039 male workers aged 40 to 64 years. Weight and height were measured, and overweight/obesity was defined as a body mass index ≥25 kg/m2. The prevalence of type 2 diabetes, defined as fasting plasma glucose ≥126 mg/dL and/or hemoglobin A1c ≥6.5% and/or self-reported physician-diagnosed diabetes, was evaluated. Odds ratios (OR) and 95% confidence intervals (95% CI) for the prevalence of type 2 diabetes were obtained using a logistic regression model. Results In total, 611 participants had type 2 diabetes, and 1763 participants were overweight/obese. After adjustment for covariates, we found an inverse association between muscle strength and the prevalence of type 2 diabetes (P for trend <0.01). In addition, when the analyses were stratified by obesity status, the multivariable-adjusted OR per 2-standard-deviation increase in muscle strength was 0.64 (95% CI, 0.49–0.83) in the overweight/obese group, compared to a weaker relationship in the normal-weight group (OR 0.79 per 2-standard-deviation increase; 95% CI, 0.60–1.06). Conclusions Dynapenia, an age-related decrease in muscle strength, is associated with increased prevalence of type 2 diabetes, and this relationship is stronger in overweight/obese middle-aged Japanese men than in normal-weight men. PMID:26256772
Fan, Jun; Qiu, Xin; Niu, Xiaodong; Tian, Zheng; Sun, Wei; Liu, Xiaojuan; Li, Yangde; Li, Weirong; Meng, Jian
2013-05-01
Mg-1.5Y-1.2Zn-0.44Zr alloys were newly developed as degradable metallic biomaterials. A comprehensive investigation of the microstructure, mechanical properties, in vitro degradation assessments and in vitro cytotoxicity evaluations of the as-cast state, as-heat treated state and as-extruded state alloys was done. The microstructure observations show that the Mg-1.5Y-1.2Zn-0.44Zr alloys are mainly composed of the matrix α-Mg phases and the Mg12ZnY secondary phases (LPS structure). The hot extrusion method significantly refined the grains and eliminated the defects of both as-cast and heat treated alloys and thereby contributed to the better mechanical properties and biodegradation resistance. The values of tensile strength and tensile yield strength of the alloy in the as-extruded condition are about 236 and 178 MPa respectively, with an excellent elongation of 28%. Meanwhile, the value of compressive strength is about 471 MPa and the value of bending strength is about 501 MPa. The superior bending strength further demonstrates the excellent ductility of the hot extruded alloys. The results of immersion tests and electrochemical measurements in the SBF indicate that a protective film precipitated on the alloy's surface with the extension of degradation. The protective film contains Mg(OH)2 and hydroxyapatite (HA) which can reinforce osteoblast activity and promote good biocompatibility. No significant cytotoxicity towards L-929 cells was detected and the immersion extracts of alloy samples could enhance the cell proliferation with time in the cytotoxicity evaluations, implying that the Mg-1.5Y-1.2Zn-0.44Zr alloys have the potential to be used for biomedical applications. Copyright © 2013 Elsevier B.V. All rights reserved.
Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires.
Albuquerque, Cibele Gonçalves de; Correr, Américo Bortolazzo; Venezian, Giovana Cherubini; Santamaria, Milton; Tubel, Carlos Alberto; Vedovello, Silvia Amélia Scudeler
2017-01-01
The aim was to evaluate the flexural strength and the effects of deflection on the surface roughness of esthetic orthodontic wires. The sample consisted of 70 archwire 0.014-inch: polytetrafluorethylene (PTFE)-coated Nickel-Titanium (Niti) archwires (Titanol Cosmetic-TC, Flexy Super Elastic Esthetic-FSE, esthetic Nickel Titanium Wire-ANT); epoxy resin-coated Niti archwires (Spectra-S, Niticosmetic-TEC); gold and rhodium coated Niti (Sentalloy-STC) and a control group (superelastic Niti (Nitinol-NS). The initial roughness was evaluated with a rugosimeter. After that, the wires were submitted to flexural test in an universal testing machine. Each wire was deflected up to 2 mm at a speed of 1 mm/min. After flexural test, the roughness of the wires was evaluted on the same surface as that used for the initial evaluation. The data of roughness and flexural strength were analyzed by one-way ANOVA and Tukey's test (a=0.05). Student t-test compared roughness before and after deflection (a =0.05). The roughness of S and ANT (epoxy resin and PTFE-coated wires, respectively), before and after deflection, was significantly higher than the other groups (p<0.05). Wire deflection significantly increased the roughness of the wires S and STC (p<0.05). The flexural strength of groups FSE and NS (PTFE and uncoated) was higher compared with that of the other groups (p<0.05). We concluded that the roughness and flexural strength of the orthodontic wires does not depend on the type of the esthetic coating, but it is influenced by the method of application of this coating. The deflection can increase the roughness of the esthetic orthodontic wires.
78 FR 60301 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... Evaluation Program (HSEEP) After Action Report (AAR) Improvement Plan (IP). DATES: Comments must be submitted...) Improvement Plan (IP) provides a standardized method for reporting the results of preparedness exercises and identifying, correcting and sharing as appropriate strengths and areas for improvement. Thus, the HSEEP AAR/IP...
Iowa Case Management for Rural Drug Abuse
ERIC Educational Resources Information Center
Hall, James A.; Vaughan Sarrazin, Mary S.; Huber, Diane L.; Vaughn, Thomas; Block, Robert I.; Reedy, Amanda R.; Jang, MiJin
2009-01-01
Objective: The purpose of this research was to evaluate the effectiveness of a comprehensive, strengths-based model of case management for clients in drug abuse treatment. Method: 503 volunteers from residential or intensive outpatient treatment were randomly assigned to one of three conditions of Iowa Case Management (ICM) plus treatment as usual…
Social Capital: Strengthening Mexican-American Families through Parenting Education
ERIC Educational Resources Information Center
Montanez, Marcel; Devall, Esther; VanLeeuwen, Dawn M.
2010-01-01
Development of social capital was explored from a scientific evaluation of adult and teen parents (N = 102) who voluntarily participated in a parenting program. Most were unmarried, young, low-income, and Mexican-American. A strengths-based, culturally specific method was utilized to recruit and retain participants. After training, parents had…
Logistics Enterprise Evaluation Model Based On Fuzzy Clustering Analysis
NASA Astrophysics Data System (ADS)
Fu, Pei-hua; Yin, Hong-bo
In this thesis, we introduced an evaluation model based on fuzzy cluster algorithm of logistics enterprises. First of all,we present the evaluation index system which contains basic information, management level, technical strength, transport capacity,informatization level, market competition and customer service. We decided the index weight according to the grades, and evaluated integrate ability of the logistics enterprises using fuzzy cluster analysis method. In this thesis, we introduced the system evaluation module and cluster analysis module in detail and described how we achieved these two modules. At last, we gave the result of the system.
Magnusen, Marshall J
2010-06-01
Leader behaviors have been found to vary by competitive level (6,9,11,26). Similar differences based on the competitive environment have been reported with strength coaches and their training emphases (15,28) but not their leadership style behaviors. This latter area is important to explore because strength coach leader behaviors may result in enhanced cooperation, improved communication, and improved athlete psychological and emotional well-being (14,23,25,27). Accordingly, the purpose of this study was to examine the differences in self-perceived leadership styles of National Basketball Association, Division I-A (DI-A) men's basketball, and Division II (DII) men's basketball strength and conditioning coaches. The self-perceived leadership styles of 145 men's basketball strength coaches (National Basketball Association [NBA]=22, DI-A=92, and DII=31) were obtained using the Revised Leadership Scale for Sport (26,41). Frequency data about demographics and training methods were also collected. No significant differences were reported for positive feedback. Otherwise, NBA strength coaches reported more democratic leadership style behaviors than DI-A strength coaches. Division I-A strength coaches were found to be more autocratic than NBA or DII strength coaches. Both NBA and DI-A strength coaches indicated a higher level of training and instruction than did DII strength coaches. National Basketball Association strength coaches also reported engaging in more situational and socially supportive leader behaviors than DI-A and DII strength coaches. Leader behaviors can positively and negatively impact an athlete (23); thus, strength coaches need to evaluate their competitive environment and reflect on the impact of their behaviors and how their approach to leading athletes may need to vary based on the situation.
Ruhdorfer, Anja; Wirth, Wolfgang; Eckstein, Felix
2016-01-01
Objective To cross-sectionally determine the quantitative relationship of age-adjusted, sex-specific isometric knee extensor and flexor strength to patient-reported knee pain. Methods Difference of thigh muscle strength by age, and that of age-adjusted strength per unit increase on the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) knee pain scale, was estimated from linear regression analysis of 4553 Osteoarthritis Initiative participants (58% women). Strata encompassing the minimal clinically important difference (MCID) in knee pain were compared to evaluate a potentially non-linear relationship between WOMAC pain levels and muscle strength. Results In Osteoarthritis Initiative participants without pain, the age-related difference in isometric knee extensor strength was −9.0%/−8.2% (women/men) per decade, and that of flexor strength was −11%/−6.9%. Differences in age-adjusted strength values for each unit of WOMAC pain (1/20) amounted to −1.9%/−1.6% for extensor and −2.5%/−1.7% for flexor strength. Differences in torque/weight for each unit of WOMAC pain ranged from −3.3 to − 2.1%. There was no indication of a non-linear relationship between pain and strength across the range of observed WOMAC values, and similar results were observed in women and men. Conclusion Each increase by 1/20 units in WOMAC pain was associated with a ~2% lower age-adjusted isometric extensor and flexor strength in either sex. As a reduction in muscle strength is known to prospectively increase symptoms in knee osteoarthritis and as pain appears to reduce thigh muscle strength, adequate therapy of pain and muscle strength is required in knee osteoarthritis patients to avoid a vicious circle of self-sustaining clinical deterioration. PMID:27836675
Oscillator strengths, first-order properties, and nuclear gradients for local ADC(2).
Schütz, Martin
2015-06-07
We describe theory and implementation of oscillator strengths, orbital-relaxed first-order properties, and nuclear gradients for the local algebraic diagrammatic construction scheme through second order. The formalism is derived via time-dependent linear response theory based on a second-order unitary coupled cluster model. The implementation presented here is a modification of our previously developed algorithms for Laplace transform based local time-dependent coupled cluster linear response (CC2LR); the local approximations thus are state specific and adaptive. The symmetry of the Jacobian leads to considerable simplifications relative to the local CC2LR method; as a result, a gradient evaluation is about four times less expensive. Test calculations show that in geometry optimizations, usually very similar geometries are obtained as with the local CC2LR method (provided that a second-order method is applicable). As an exemplary application, we performed geometry optimizations on the low-lying singlet states of chlorophyllide a.
Laboratory test for ice adhesion strength using commercial instrumentation.
Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J
2014-01-21
A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.
Tofthagen, Cindy; Visovsky, Constance; Berry, Donna L
2012-09-01
To evaluate the evidence for strength- and balance-training programs in patients at high risk for falls, discuss how results of existing studies might guide clinical practice, and discuss directions for additional research. A search of PubMed and CINAHL® databases was conducted in June 2011 using the terms strength, balance training, falls, elderly, and neuropathy. Only clinical trials conducted using specific strength- or balance-training exercises that included community-dwelling adults and examined falls, fall risk, balance, and/or strength as outcome measures were included in this review. One matched case-control study and two randomized, controlled studies evaluating strength and balance training in patients with diabetes-related peripheral neuropathy were identified. Eleven studies evaluating strength and balance programs in community-dwelling adults at high risk for falls were identified. The findings from the reviewed studies provide substantial evidence to support the use of strength and balance training for older adults at risk for falls, and detail early evidence to support strength and balance training for individuals with peripheral neuropathy. The evidence demonstrates that strength and balance training is safe and effective at reducing falls and improving lower extremity strength and balance in adults aged 50 years and older at high risk for falls, including patients with diabetic peripheral neuropathy. Future studies should evaluate the effects of strength and balance training in patients with cancer, particularly individuals with chemotherapy-induced peripheral neuropathy.
Marketing the dental practice: eight steps toward success.
McGuigan, Patrick J; Eisner, Alan B
2006-10-01
The authors provide a suggested framework for completing a comprehensive evaluation of practice processes and routines. Their approach focuses on improving the professional image of dentists and the methods they use to market themselves. A practice can benefit by implementing a program to understand the strengths and weaknesses of the practice and how these strengths and weaknesses affect patients' experiences. A word-of-mouth marketing campaign relies on the cultivation of opinion leaders, but opinion leaders cannot be cultivated until they have been identified. Dental practice marketing campaigns cannot be based on assumptions; they must be based on facts. Practice Implications. Improving relationships with patients will lead to increased patient retention, reduced marketing costs and greater personal satisfaction. By focusing on strengths, clinicians will improve patients' experiences in the dental office.
Time-dependent reliability analysis of ceramic engine components
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.
1993-01-01
The computer program CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program. CARES/LIFE accounts for the phenomenon of subcritical crack growth (SCG) by utilizing either the power or Paris law relations. The two-parameter Weibull cumulative distribution function is used to characterize the variation in component strength. The effects of multiaxial stresses are modeled using either the principle of independent action (PIA), the Weibull normal stress averaging method (NSA), or the Batdorf theory. Inert strength and fatigue parameters are estimated from rupture strength data of naturally flawed specimens loaded in static, dynamic, or cyclic fatigue. Two example problems demonstrating proof testing and fatigue parameter estimation are given.
Robustness analysis of elastoplastic structure subjected to double impulse
NASA Astrophysics Data System (ADS)
Kanno, Yoshihiro; Takewaki, Izuru
2016-11-01
The double impulse has extensively been used to evaluate the critical response of an elastoplastic structure against a pulse-type input, including near-fault earthquake ground motions. In this paper, we propose a robustness assessment method for elastoplastic single-degree-of-freedom structures subjected to the double impulse input. Uncertainties in the initial velocity of the input, as well as the natural frequency and the strength of the structure, are considered. As fundamental properties of the structural robustness, we show monotonicity of the robustness measure with respect to the natural frequency. In contrast, we show that robustness is not necessarily improved even if the structural strength is increased. Moreover, the robustness preference between two structures with different values of structural strength can possibly reverse when the performance requirement is changed.
Weiqi Leng; John F. Hunt; Mehdi Tajvidi
2017-01-01
Wet-formed particleboard bonded with cellulose nanofibrils (CNF) was prepared in this work. The effects of density, CNF addition ratio, pressing method, and particle size on the bending strength were evaluated. The results showed that density had the most important effect on the modulus of elasticity (MOE), while the CNF addition ratio had the most important effect on...
The Use of Land Power to Counter the Iranian Nuclear Proliferation Challenge
2007-06-15
US actions by regional and global opponents (al Qaeda, Russia, etc) to an invasion. Specifically, I will not address the potential for the con spread...facilities will not neutralize the facilities in the long-term, and air attacks will inspire Iranian nationalism against pro -US change. It may not be...thesis committee. Other evaluation methods considered included the strengths-weaknesses-opportunities-threats ( SWOT ) method, and the diplomacy
Comparison of Provider Types Who Performed Prehospital Lifesaving Interventions: A Prospective Study
2014-12-01
In less than 2 hours, 15 critically ill children were triaged and admitted to the PICU or surge spaces. Conclusions:Identified strengths included...details increasing telemedicine uti - lization during a 4 year period and outlines program structural changes that improved utilization. Methods: The study...population survival. CSC ICU resource- allocation algorithms (ALGs) exist for adults. Our goal was to evaluate a CSC pandemic ALG for children . Methods
Miciak, Jeremy; Taylor, Pat; Denton, Carolyn A.; Fletcher, Jack M.
2014-01-01
Purpose Few empirical investigations have evaluated learning disabilities (LD) identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability of LD classification decisions of the concordance/discordance method (C/DM) across different psychoeducational assessment batteries. Methods C/DM criteria were applied to assessment data from 177 second grade students based on two psychoeducational assessment batteries. The achievement tests were different, but were highly correlated and measured the same latent construct. Resulting LD identifications were then evaluated for agreement across batteries on LD status and the academic domain of eligibility. Results The two batteries identified a similar number of participants as having LD (80 and 74). However, indices of agreement for classification decisions were low (kappa = .29), especially for percent positive agreement (62%). The two batteries demonstrated agreement on the academic domain of eligibility for only 25 participants. Conclusions Cognitive discrepancy frameworks for LD identification are inherently unstable because of imperfect reliability and validity at the observed level. Methods premised on identifying a PSW profile may never achieve high reliability because of these underlying psychometric factors. An alternative is to directly assess academic skills to identify students in need of intervention. PMID:25243467
Jaidka, Shipra; Somani, Rani; Singh, Deepti J; Shafat, Shazia
2016-04-01
To comparatively evaluate the compressive strength, diametral tensile strength, and shear bond strength of glass ionomer cement type IX, chlorhexidine-incorporated glass ionomer cement, and triclosan-incorporated glass ionomer cement. In this study, glass ionomer cement type IX was used as a control. Chlorhexidine diacetate, and triclosan were added to glass ionomer cement type IX powder, respectively, in order to obtain 0.5, 1.25, and 2.5% concentrations of the respective experimental groups. Compressive strength, diametral tensile strength, and shear bond strength were evaluated after 24 h using Instron Universal Testing Machine. The results obtained were statistically analyzed using the independent t-test, Dunnett test, and Tukey test. There was no statistical difference in the compressive strength, diametral tensile strength, and shear bond strength of glass ionomer cement type IX (control), 0.5% triclosan-glass ionomer cement, and 0.5% chlorhexidine-glass ionomer cement. The present study suggests that the compressive strength, diametral tensile strength, and shear bond strength of 0.5% triclosan-glass ionomer cement and 0.5% chlorhexidine-glass ionomer cement were similar to those of the glass ionomer cement type IX, discernibly signifying that these can be considered as viable options for use in pediatric dentistry with the additional value of antimicrobial property along with physical properties within the higher acceptable range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dittrich, Timothy M.; Richmann, Michael K.; Reed, Donald T.
2015-10-30
The degree of conservatism in the estimated sorption partition coefficients (K ds) used in a performance assessment model is being evaluated based on a complementary batch and column method. The main focus of this work is to investigate the role of ionic strength, solution chemistry, and oxidation state (III-VI) in actinide sorption to dolomite rock. Based on redox conditions and solution chemistry expected at the WIPP, possible actinide species include Pu(III), Pu(IV), U(IV), U(VI), Np(IV), Np(V), Am(III), and Th(IV).
Detection and Phenotypic Characterization of Adult Neurogenesis
Kuhn, H. Georg; Eisch, Amelia J.; Spalding, Kirsty; Peterson, Daniel A.
2016-01-01
Studies of adult neurogenesis have greatly expanded in the last decade, largely as a result of improved tools for detecting and quantifying neurogenesis. In this review, we summarize and critically evaluate detection methods for neurogenesis in mammalian and human brain tissue. Besides thymidine analog labeling, cell-cycle markers are discussed, as well as cell stage and lineage commitment markers. Use of these histological tools is critically evaluated in terms of their strengths and limitations, as well as possible artifacts. Finally, we discuss the method of radiocarbon dating for determining cell and tissue turnover in humans. PMID:26931327
RNA-Puzzles: A CASP-like evaluation of RNA three-dimensional structure prediction
Cruz, José Almeida; Blanchet, Marc-Frédérick; Boniecki, Michal; Bujnicki, Janusz M.; Chen, Shi-Jie; Cao, Song; Das, Rhiju; Ding, Feng; Dokholyan, Nikolay V.; Flores, Samuel Coulbourn; Huang, Lili; Lavender, Christopher A.; Lisi, Véronique; Major, François; Mikolajczak, Katarzyna; Patel, Dinshaw J.; Philips, Anna; Puton, Tomasz; Santalucia, John; Sijenyi, Fredrick; Hermann, Thomas; Rother, Kristian; Rother, Magdalena; Serganov, Alexander; Skorupski, Marcin; Soltysinski, Tomasz; Sripakdeevong, Parin; Tuszynska, Irina; Weeks, Kevin M.; Waldsich, Christina; Wildauer, Michael; Leontis, Neocles B.; Westhof, Eric
2012-01-01
We report the results of a first, collective, blind experiment in RNA three-dimensional (3D) structure prediction, encompassing three prediction puzzles. The goals are to assess the leading edge of RNA structure prediction techniques; compare existing methods and tools; and evaluate their relative strengths, weaknesses, and limitations in terms of sequence length and structural complexity. The results should give potential users insight into the suitability of available methods for different applications and facilitate efforts in the RNA structure prediction community in ongoing efforts to improve prediction tools. We also report the creation of an automated evaluation pipeline to facilitate the analysis of future RNA structure prediction exercises. PMID:22361291
NASA Technical Reports Server (NTRS)
Manro, M. E.
1983-01-01
Two separated flow computer programs and a semiempirical method for incorporating the experimentally measured separated flow effects into a linear aeroelastic analysis were evaluated. The three dimensional leading edge vortex (LEV) code is evaluated. This code is an improved panel method for three dimensional inviscid flow over a wing with leading edge vortex separation. The governing equations are the linear flow differential equation with nonlinear boundary conditions. The solution is iterative; the position as well as the strength of the vortex is determined. Cases for both full and partial span vortices were executed. The predicted pressures are good and adequately reflect changes in configuration.
García-Sanz, Verónica; Bellot-Arcís, Carlos; Mendoza-Yero, Omel; Doñate-Buendía, Carlos; Montero, Javier; Albaladejo, Alberto
2017-01-01
Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond laser-treated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irradiation. Each group was divided into 2 subgroups (metallic vs ceramic brackets). SBS was evaluated using a universal testing machine. The adhesive remnant index (ARI) was registered and surfaces were observed under SEM. Surface treatment and bracket type significantly affected the bracket-zirconia bond strength. SBS was significantly higher (p<0.001) for ceramic brackets in all groups (APA+FS > APA > FS > SC > control) than metallic brackets (APA+FS > FS > SC > APA > control). For metallic brackets, groups SC (5.99 ± 1.86 MPa), FS (6.72 ± 2.30 MPa) and APA+FS (7.22 ± 2.73 MPa) reported significantly higher bond strengths than other groups (p < 0.05). For ceramic brackets, the highest bond strength values were obtained in groups APA (25.01 ± 4.45 MPa), FS (23.18 ± 6.51 MPa) and APA+FS (29.22 ± 8.20 MPa).Femtosecond laser enhances bond strength of ceramic and metallic brackets to zirconia. Ceramic brackets provide significantly stronger adhesion than metallic brackets regardless of the surface treatment method. PMID:29049418
The Gap in Big Data: Getting to Wellbeing, Strengths, and a Whole-person Perspective
Peters, Judith; Schlesner, Sara; Vanderboom, Catherine E.; Holland, Diane E.
2015-01-01
Background: Electronic health records (EHRs) provide a clinical view of patient health. EHR data are becoming available in large data sets and enabling research that will transform the landscape of healthcare research. Methods are needed to incorporate wellbeing dimensions and strengths in large data sets. The purpose of this study was to examine the potential alignment of the Wellbeing Model with a clinical interface terminology standard, the Omaha System, for documenting wellbeing assessments. Objective: To map the Omaha System and Wellbeing Model for use in a clinical EHR wellbeing assessment and to evaluate the feasibility of describing strengths and needs of seniors generated through this assessment. Methods: The Wellbeing Model and Omaha System were mapped using concept mapping techniques. Based on this mapping, a wellbeing assessment was developed and implemented within a clinical EHR. Strengths indicators and signs/symptoms data for 5 seniors living in a residential community were abstracted from wellbeing assessments and analyzed using standard descriptive statistics and pattern visualization techniques. Results: Initial mapping agreement was 93.5%, with differences resolved by consensus. Wellbeing data analysis showed seniors had an average of 34.8 (range=22-49) strengths indicators for 22.8 concepts. They had an average of 6.4 (range=4-8) signs/symptoms for an average of 3.2 (range=2-5) concepts. The ratio of strengths indicators to signs/symptoms was 6:1 (range 2.8-9.6). Problem concepts with more signs/symptoms had fewer strengths. Conclusion: Together, the Wellbeing Model and the Omaha System have potential to enable a whole-person perspective and enhance the potential for a wellbeing perspective in big data research in healthcare. PMID:25984416
The effect of denture base surface pretreatments on bond strengths of two long term resilient liners
Parkhedkar, Rambhau
2011-01-01
PURPOSE Purpose of this study was to evaluate effect of two surface treatments, sandblasting and monomer treatment, on tensile bond strength between two long term resilient liners and poly (methyl methacrylate) denture base resin. MATERIALS AND METHODS Two resilient liners Super-Soft and Molloplast-B were selected.Sixty acrylic resin (Trevalon) specimens with cross sectional area of 10×10 mm were prepared and divided into two groups of 30 specimens each. Each group was surface treated (n = 10) by sandblasting (250 µ alumina particles), monomer treatment (for 180 sec) and control (no surface treatment). Resilient liners were processed between 2 poly(methyl methacrylate) surfaces, in the dimensions of 10×10×3 mm. Tensile strength was determined with Instron Universal testing machine, at a crosshead speed of 5 mm/min; and the modes of failure (adhesive, cohesive or mixed) were recorded. The data were analyzed using one-way ANOVA, followed by Tukey HSD test (α = 0.05). RESULTS Monomer pretreatment of acrylic resin produced significantly higher bond strengths when compared to sandblasting and control for both resilient liners (P < .001). Sandblasting significantly decreased the bond strength for both the liners when compared to monomer pretreatment and control (P < .001). Mean bond strength of Super-Soft lined specimens was significantly higher than Molloplast-B in various surface treatment groups (P < .05). CONCLUSION Surface pretreatment of the acrylic resin with monomer prior to resilient liner application is an effective method to increase bond strength between the base and soft liner. Sandblasting, on the contrary, is not recommended as it weakens the bond between the two. PMID:21503188
García-Sanz, Verónica; Paredes-Gallardo, Vanessa; Bellot-Arcís, Carlos; Mendoza-Yero, Omel; Doñate-Buendía, Carlos; Montero, Javier; Albaladejo, Alberto
2017-01-01
Femtosecond laser has been proposed as a method for conditioning zirconia surfaces to boost bond strength. However, metallic or ceramic bracket bonding to femtosecond laser-treated zirconia surfaces has not been tested. This study compared the effects of four conditioning techniques, including femtosecond laser irradiation, on shear bond strength (SBS) of metallic and ceramic brackets to zirconia.Three hundred zirconia plates were divided into five groups: 1) control (C); 2) sandblasting (APA); 3) silica coating and silane (SC); 4) femtosecond laser (FS); 5) sandblasting followed by femtosecond laser (APA+SC). A thermal imaging camera measured temperature changes in the zirconia during irradiation. Each group was divided into 2 subgroups (metallic vs ceramic brackets). SBS was evaluated using a universal testing machine. The adhesive remnant index (ARI) was registered and surfaces were observed under SEM. Surface treatment and bracket type significantly affected the bracket-zirconia bond strength. SBS was significantly higher (p<0.001) for ceramic brackets in all groups (APA+FS > APA > FS > SC > control) than metallic brackets (APA+FS > FS > SC > APA > control). For metallic brackets, groups SC (5.99 ± 1.86 MPa), FS (6.72 ± 2.30 MPa) and APA+FS (7.22 ± 2.73 MPa) reported significantly higher bond strengths than other groups (p < 0.05). For ceramic brackets, the highest bond strength values were obtained in groups APA (25.01 ± 4.45 MPa), FS (23.18 ± 6.51 MPa) and APA+FS (29.22 ± 8.20 MPa).Femtosecond laser enhances bond strength of ceramic and metallic brackets to zirconia. Ceramic brackets provide significantly stronger adhesion than metallic brackets regardless of the surface treatment method.
Electric field strength determination in filamentary DBDs by CARS-based four-wave mixing
NASA Astrophysics Data System (ADS)
Boehm, Patrick; Kettlitz, Manfred; Brandenburg, Ronny; Hoeft, Hans; Czarnetzki, Uwe
2016-09-01
The electric field strength is a basic parameter of non-thermal plasmas. Therefore, a profound knowledge of the electric field distribution is crucial. In this contribution a four wave mixing technique based on Coherent Anti-Stokes Raman spectroscopy (CARS) is used to measure electric field strengths in filamentary dielectric barrier discharges (DBDs). The discharges are operated with a pulsed voltage in nitrogen at atmospheric pressure. Small amounts hydrogen (10 vol%) are admixed as tracer gas to evaluate the electric field strength in the 1 mm discharge gap. Absolute values of the electric field strength are determined by calibration of the CARS setup with high voltage amplitudes below the ignition threshold of the arrangement. Alteration of the electric field strength has been observed during the internal polarity reversal and the breakdown process. In this case the major advantage over emission based methods is that this technique can be used independently from emission, e.g. in the pre-phase and in between two consecutive, opposite discharge pulses where no emission occurs at all. This work was supported by the Deutsche Forschungsgemeinschaft, Forschergruppe FOR 1123 and Sonderforschungsbereich TRR 24 ``Fundamentals of complex plasmas''.
The ACTN3 R577X variant in sprint and strength performance
Kim, Hyeoijin; Song, Keon-Hyoung; Kim, Chul-Hyun
2014-01-01
[Purpose] The aim of this study is to examine the association between the distribution of ACTN3 genotypes and alleles in power, speed, and strength-oriented athletics. [Methods] ACTN3 genotyping was carried out for a total of 975 Korean participants: top-level sprinters (n = 58), top-level strength athletes (n = 63), and healthy controls (n = 854). [Results] Genetic associations were evaluated by chi-squire test or Fisher’s exact test. In the power-oriented group composed of sprinters and strength athletes, the frequency of the XX genotype was significantly underrepresented (11.6%) in comparison to its representation in the control group (11.6% versus 19.1%, P < 0.05). When the power-oriented group was divided into strength-oriented and speed-oriented groups, no significant difference in the ACTN3 XX genotype was found between the strength-oriented athletes and the controls (15.9% versus 19.1%, P < 0.262). Only the speed-oriented athletes showed significant differences in the frequency distributions of the ACTN3 XX genotype (6.9% versus 19.1%, P < 0.05) from that of the controls. [Conclusion] The ACTN3 genotype seems to mainly affect sports performance and especially speed. PMID:25671201
Blasted copper slag as fine aggregate in Portland cement concrete.
Dos Anjos, M A G; Sales, A T C; Andrade, N
2017-07-01
The present work focuses on assessing the viability of applying blasted copper slag, produced during abrasive blasting, as fine aggregate for Portland cement concrete manufacturing, resulting in an alternative and safe disposal method. Leaching assays showed no toxicity for this material. Concrete mixtures were produced, with high aggregate replacement ratios, varying from 0% to 100%. Axial compressive strength, diametrical compressive strength, elastic modulus, physical indexes and durability were evaluated. Assays showed a significant improvement in workability, with the increase in substitution of fine aggregate. With 80% of replacement, the concrete presented lower levels of water absorption capacity. Axial compressive strength and diametrical compressive strength decreased, with the increase of residue replacement content. The greatest reductions of compressive strength were found when the replacement was over 40%. For tensile strength by diametrical compression, the greatest reduction occurred for the concrete with 80% of replacement. After the accelerated aging, results of mechanic properties showed a small reduction of the concrete with blasted copper slag performance, when compared with the reference mixture. Results indicated that the blasted copper slag is a technically viable material for application as fine aggregate for concrete mixtures. Copyright © 2017 Elsevier Ltd. All rights reserved.
2013-01-01
Background Knee extensor strength and knee extension range of motion (ROM) are important predictors of physical function in patients with a total knee arthroplasty (TKA). However, the relationship between the two knee measures remains unclear. The purpose of this study was to examine whether changes in knee extensor strength mediate the association between changes in knee extension ROM and self-report physical function. Methods Data from 441 patients with a TKA were collected preoperatively and 6 months postoperatively. Self-report measure of physical function was assessed by the Short Form 36 (SF-36) questionnaire. Knee extensor strength was measured by handheld dynamometry and knee extension ROM by goniometry. A bootstrapped cross product of coefficients approach was used to evaluate mediation effects. Results Mediation analyses, adjusted for clinicodemographic measures, revealed that the association between changes in knee extension ROM and SF-36 physical function was mediated by changes in knee extensor strength. Conclusions In patients with TKA, knee extensor strength mediated the influence of knee extension ROM on physical function. These results suggest that interventions to improve the range of knee extension may be useful in improving knee extensor performance. PMID:23332039
Damage characterization in dimension limestone cladding using noncollinear ultrasonic wave mixing
NASA Astrophysics Data System (ADS)
McGovern, Megan; Reis, Henrique
2016-01-01
A method capable of characterizing artificial weathering damage in dimension stone cladding using access to one side only is presented. Dolomitic limestone test samples with increasing levels of damage were created artificially by exposing undamaged samples to increasing temperature levels of 100°C, 200°C, 300°C, 400°C, 500°C, 600°C, and 700°C for a 90 min period of time. Using access to one side only, these test samples were nondestructively evaluated using a nonlinear approach based upon noncollinear wave mixing, which involves mixing two critically refracted dilatational ultrasonic waves. Criteria were used to assure that the detected scattered wave originated via wave interaction in the limestone and not from nonlinearities in the testing equipment. Bending tests were used to evaluate the flexure strength of beam samples extracted from the artificially weathered samples. It was observed that the percentage of strength reduction is linearly correlated (R2=98) with the temperature to which the specimens were exposed; it was noted that samples exposed to 400°C and 600°C had a strength reduction of 60% and 90%, respectively. It was also observed that results from the noncollinear wave mixing approach correlated well (R2=0.98) with the destructively obtained percentage of strength reduction.
Low agreement between the fitnessgram criterion references for adolescents
Coledam, Diogo Henrique Constantino; Batista, João Pedro; Glaner, Maria Fátima
2015-01-01
OBJECTIVE: To analyze the association and agreement of fitnessgram reference criteria (RC) for cardiorespiratory fitness, body mass index (BMI) and strength in youth. METHODS: The study included 781 youth, 386 females, aged 10 to 18 years of Londrina-PR. It were performed cardiorespiratory fitness and muscular strength tests and was calculated body mass index. The association between the tests was analyzed using Poisson regression to obtain prevalence ratio (PR) and confidence intervals of 95%, while agreement of the reference criteria was tested by Kappa index. RESULTS: Significant associations were found between cardiorespiratory fitness and BMI (PR=1,49, 1,27-1,75), muscle strength and BMI (PR=1,55, 1,17-2,08), cardiorespiratory fitness and muscle strength (PR=1,81, 1,47-2,24). The agreement between reference criteria ranged from weak to fair, 48.8% (k=0.05, p=0.10) for cardiorespiratory fitness and BMI, 52.9% (k=0.09, p=0.001) for muscle strength and BMI and 38.4% (k=0.22, p<0.001) for cardiorespiratory fitness and muscle strength. CONCLUSIONS: Although RC for cardiorespiratory fitness, muscle strength and BMI are associated, the agreement between them ranged from weak to fair. To evaluate health related physical fitness it is suggest the execution of all tests, since each test has specific characteristics. PMID:25649383
Zhang, Bin; Haines, Morgan B.; Kelchner, Lisa N.
2017-01-01
Purpose This systematic review summarizes the effects of isometric lingual strength training on lingual strength and swallow function in adult populations. Furthermore, it evaluates the designs of the reviewed studies and identifies areas of future research in isometric lingual strength training for dysphagia remediation. Method A comprehensive literature search of 3 databases and additional backward citation search identified 10 studies for inclusion in the review. The review reports and discusses the isometric-exercise intervention protocols, pre- and postintervention lingual-pressure data (maximum peak pressures and lingual-palatal pressures during swallowing), and oropharyngeal swallowing measures such as penetration-aspiration scales, oropharyngeal residue and duration, lingual volumes, and quality-of-life assessments. Results Studies reported gains in maximum peak lingual pressures following isometric lingual strength training for both healthy adults and select groups of individuals with dysphagia. However, due to the variability in study designs, it remains unclear whether strength gains generalize to swallow function. Conclusion Although isometric lingual strength training is a promising intervention for oropharyngeal dysphagia, the current literature is too variable to confidently report specific therapeutic benefits. Future investigations should target homogenous patient populations and use randomized controlled trials to determine the efficacy of this treatment for individuals with dysphagia. PMID:28282484
Strength training, but not endurance training, reduces motor unit discharge rate variability.
Vila-Chã, Carolina; Falla, Deborah
2016-02-01
This study evaluates and compares the effects of strength and endurance training on motor unit discharge rate variability and force steadiness of knee extensor muscles. Thirty sedentary healthy men (age, 26.0±3.8yrs) were randomly assigned to strength training, endurance training or a control group. Conventional endurance and strength training was performed 3days per week, over a period of 6weeks. Maximum voluntary contraction (MVC), time to task failure (at 30% MVC), coefficient of variation (CoV) of force and of the discharges rates of motor units from the vastus medialis obliquus and vastus lateralis were determined as subjects performed 20% and 30% MVC knee extension contractions before and after training. CoV of motor unit discharges rates was significantly reduced for both muscles following strength training (P<0.001), but did not change in the endurance (P=0.875) or control group (P=0.995). CoV of force was reduced after the strength training intervention only (P<0.01). Strength training, but not endurance training, reduces motor unit discharge rate variability and enhances force steadiness of the knee extensors. These results provide new insights into the neuromuscular adaptations that occur with different training methods. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effect of dropped plies on the strength of graphite-epoxy laminates
NASA Technical Reports Server (NTRS)
Curry, James M.; Johnson, Eric R.; Starnes, James H., Jr.
1987-01-01
The reduction in the compressive and tensile strengths of graphite-epoxy laminates with thickness discontinuities due to dropped plies was studied by experiment and analysis. The specimens were fabricated with all the dropped plies lumped together in the center of a sixteen-ply quasi-isotropic layup, such that one surface was flat and the slope of the opposite surface changed abruptly at the dropped ply location to accommodate the thickness change. Even though the thick and thin sections are symmetrically laminated, there exists bending-extension coupling due to the geometric eccentricity of the middle planes of the thick and thin sections. Experiments were conducted on fifty-four specimens that differed in the configuration of the dropped plies only. The strength of a laminate with dropped plies is less than the strength of its thin section, and the compressive strength of a laminate with dropped plies is less than its tensile strength. The reduction in strength is directly related to the axial stiffness change between the thick and thin sections. To examine the mechanism of failure, the three-dimensional state of stress in the dropped ply region was evaluated by the finite element method. A tensile interlaminar criterion predicted the correct location of failure, but underestimated the failure load.
Raji, S. Hamid; Ghorbanipour, Reza; Majdzade, Fateme
2011-01-01
Background: The aim of this study was to evaluate the shear bond strength of an antimicrobial and fluoride-releasing self-etch primer (clearfil protect bond) and compare it with transbond plus self-etch primer and conventional acid etching and priming system. Materials and Methods: Forty-eight extracted human premolars were divided randomly to three groups. In group 1, the teeth were bonded with conventional acid etching and priming method. In group 2, the teeth were bonded with clearfil protect bond self-etch primer, and transbond plus self-etch primer was used to bond the teeth in group 3. The samples were stored in 37°C distilled water and thermocycled. Then, the SBS of the sample was evaluated with Zwick testing machine. Descriptive statistics and the analysis of variances (ANOVA) and Tukey's test and Kruskal-Wallis were used to analyze the data. Results: The results of the ANOVA showed that the mean of group 3 was significantly lower than that of other groups. Most of the sample showed a pattern of failure within the adhesive resin. Conclusion: The shear bond strength of clearfil protect bond and transbond plus self-etch primer was enough for bonding the orthodontic brackets. The mode of failure of bonded brackets with these two self-etch primers is safe for enamel. PMID:23372605
Lee, Soo Jung; Kim, Hyun Joo; Cho, Eun Jin; Song, Younho; Bae, Hyeun-Jong
2015-01-01
Lignin was isolated from the residue of bioethanol production with oak wood via alkaline and catalyzed organosolv treatments at ambient temperature to improve the purity of lignin for the materials application. The isolated lignins were analyzed for their chemical composition by nitrobenzene oxidation method and their functionality was characterized via wet chemistry method, element analysis, (1)H NMR, GPC and FTIR-ATR. The isolated lignin by acid catalyzed organosolv treatment (Acid-OSL) contained a higher lignin content, aromatic proton, phenolic hydroxyl group and a lower nitrogen content that is more reactive towards chemical modification. The lignin-based adhesives were prepared and the bond strength was measured to evaluate the enhanced reactivity of lignin by the isolation. Two steps of phenolation and methylolation were applied for the modification of the isolated lignins and their tensile strengths were evaluated for the use as an adhesive. The acid catalyzed organosolv lignin-based adhesives had comparable bond strength to phenol-formaldehyde adhesives. The analysis of lignin-based adhesives by FTIR-ATR and TGA showed structural similarity to phenol adhesive. The results demonstrate that the reactivity of lignin was enhanced by isolation from hardwood bioethanol production residues at ambient temperature and it could be used in a value-added application to produce lignin-based adhesives. Copyright © 2014 Elsevier B.V. All rights reserved.
Spintzyk, Sebastian; Yamaguchi, Kikue; Sawada, Tomofumi; Schille, Christine; Schweizer, Ernst; Ozeki, Masahiko; Geis-Gerstorfer, Jürgen
2016-01-01
This study evaluated the bond strength of veneering porcelain with an experimental conditioner-coated zirconia. Pre-sintered Y-TZP specimens (n = 44) were divided in two groups based on conditioning type. After sintering, all sample surfaces were sandblasted and layered with veneering porcelain. Additionally, half of the specimens in each group underwent thermal cycling (10,000 cycles, 5–55 °C), and all shear bond strengths were measured. After testing, the failure mode of each fractured specimen was determined. Differences were tested by parametric and Fisher’s exact tests (α = 0.05). The differences in bond strength were not statistically significant. Adhesive fractures were dominantly observed for the non-thermal cycled specimens. After thermal cycling, the conditioner-coated group showed cohesive and mixed fractures (p = 0.0021), whereas the uncoated group showed more adhesive fractures (p = 0.0021). Conditioning of the pre-sintered Y-TZP did not change the shear bond strength of the veneering porcelain, but did improve the failure mode after thermal cycling. PMID:28773885
Development program to produce mullite fiber insulation
NASA Technical Reports Server (NTRS)
Long, W. G.
1975-01-01
Processing methods were utilized to form a mullite fiber-Kaowool felt. The formation of a blended felt using the Rotoformer wet-laying method was successful. Felt products were evaluated for tensile strength, thermal stability, thermal conductivity and structural integrity at 1259 C and 1371 C. Textile processing methods failed in an attempt to form a yarn from staple and multifilament mullite fiber due to fiber damage through mechanical handling. The refractoriness of pure Kaowool ceramic fiber is improved with additions of 30% or greater mullite fiber.
NASA Astrophysics Data System (ADS)
Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.
2017-09-01
The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.
NASA Astrophysics Data System (ADS)
Zheng, Y.; Chen, J.
2017-09-01
A modified multi-objective particle swarm optimization method is proposed for obtaining Pareto-optimal solutions effectively. Different from traditional multi-objective particle swarm optimization methods, Kriging meta-models and the trapezoid index are introduced and integrated with the traditional one. Kriging meta-models are built to match expensive or black-box functions. By applying Kriging meta-models, function evaluation numbers are decreased and the boundary Pareto-optimal solutions are identified rapidly. For bi-objective optimization problems, the trapezoid index is calculated as the sum of the trapezoid's area formed by the Pareto-optimal solutions and one objective axis. It can serve as a measure whether the Pareto-optimal solutions converge to the Pareto front. Illustrative examples indicate that to obtain Pareto-optimal solutions, the method proposed needs fewer function evaluations than the traditional multi-objective particle swarm optimization method and the non-dominated sorting genetic algorithm II method, and both the accuracy and the computational efficiency are improved. The proposed method is also applied to the design of a deepwater composite riser example in which the structural performances are calculated by numerical analysis. The design aim was to enhance the tension strength and minimize the cost. Under the buckling constraint, the optimal trade-off of tensile strength and material volume is obtained. The results demonstrated that the proposed method can effectively deal with multi-objective optimizations with black-box functions.
Jäger, Jessica
2013-07-01
This article reports on a follow-up study exploring the use of play-based evaluation methods to facilitate children's views of therapy. The development and piloting of these techniques, with 12 children in the author's own practice, was previously reported in this journal. It was argued that play-based evaluation methods reduce the power imbalance inherent in adult researcher/interviewer-child relationships and provide children with meaningful ways to share their views. In this article, follow-up research into play-based evaluations with 20 children and 7 different play therapists is drawn upon to explore in greater depth the strengths and weaknesses of these techniques. The study shows that play-based evaluation techniques are important and flexible methods for facilitating children's views of child therapy. It is argued that those play therapists who incorporate their therapeutic skills effectively, maintain flexibility and sensitively attune to the child during the evaluation session, enable the child to explore their views most fully.
Practical approach to subject-specific estimation of knee joint contact force.
Knarr, Brian A; Higginson, Jill S
2015-08-20
Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data; however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models' predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. Copyright © 2015 Elsevier Ltd. All rights reserved.
Practical approach to subject-specific estimation of knee joint contact force
Knarr, Brian A.; Higginson, Jill S.
2015-01-01
Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data, however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models’ predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. PMID:25952546
NASA Astrophysics Data System (ADS)
Yin, Zhifu; Sun, Lei; Zou, Helin; Cheng, E.
2015-05-01
A method for obtaining a low-cost and high-replication precision two-dimensional (2D) nanofluidic device with a polymethyl methacrylate (PMMA) sheet is proposed. To improve the replication precision of the 2D PMMA nanochannels during the hot embossing process, the deformation of the PMMA sheet was analyzed by a numerical simulation method. The constants of the generalized Maxwell model used in the numerical simulation were calculated by experimental compressive creep curves based on previously established fitting formula. With optimized process parameters, 176 nm-wide and 180 nm-deep nanochannels were successfully replicated into the PMMA sheet with a replication precision of 98.2%. To thermal bond the 2D PMMA nanochannels with high bonding strength and low dimensional loss, the parameters of the oxygen plasma treatment and thermal bonding process were optimized. In order to measure the dimensional loss of 2D nanochannels after thermal bonding, a dimension loss evaluating method based on the nanoindentation experiments was proposed. According to the dimension loss evaluating method, the total dimensional loss of 2D nanochannels was 6 nm and 21 nm in width and depth, respectively. The tensile bonding strength of the 2D PMMA nanofluidic device was 0.57 MPa. The fluorescence images demonstrate that there was no blocking or leakage over the entire microchannels and nanochannels.
NASA Technical Reports Server (NTRS)
Malone, G. A.; Vecchies, L.; Wood, R.
1974-01-01
The capabilities and limitations of nondestructive evaluation methods were studied to detect and locate bond deficiencies in regeneratively cooled thrust chambers for rocket engines. Flat test panels and a cylinder were produced to simulate regeneratively cooled thrust chamber walls. Planned defects with various bond integrities were produced in the panels to evaluate the sensitivity, accuracy, and limitations of nondestructive methods to define and locate bond anomalies. Holography, acoustic emission, and ultrasonic scan were found to yield sufficient data to discern bond quality when used in combination and in selected sequences. Bonding techniques included electroforming and brazing. Materials of construction included electroformed nickel bonded to Nickel 200 and OFHC copper, electroformed copper bonded to OFHC copper, and 300 series stainless steel brazed to OFHC copper. Variations in outer wall strength, wall thickness, and defect size were evaluated for nondestructive test response.
Zhou, Ronggang; Chan, Alan H. S.
2016-01-01
BACKGROUND: In order to compare existing usability data to ideal goals or to that for other products, usability practitioners have tried to develop a framework for deriving an integrated metric. However, most current usability methods with this aim rely heavily on human judgment about the various attributes of a product, but often fail to take into account of the inherent uncertainties in these judgments in the evaluation process. OBJECTIVE: This paper presents a universal method of usability evaluation by combining the analytic hierarchical process (AHP) and the fuzzy evaluation method. By integrating multiple sources of uncertain information during product usability evaluation, the method proposed here aims to derive an index that is structured hierarchically in terms of the three usability components of effectiveness, efficiency, and user satisfaction of a product. METHODS: With consideration of the theoretical basis of fuzzy evaluation, a two-layer comprehensive evaluation index was first constructed. After the membership functions were determined by an expert panel, the evaluation appraisals were computed by using the fuzzy comprehensive evaluation technique model to characterize fuzzy human judgments. Then with the use of AHP, the weights of usability components were elicited from these experts. RESULTS AND CONCLUSIONS: Compared to traditional usability evaluation methods, the major strength of the fuzzy method is that it captures the fuzziness and uncertainties in human judgments and provides an integrated framework that combines the vague judgments from multiple stages of a product evaluation process. PMID:28035943
Compressive Strength Evaluation in Brazed ZrO2/Ti6Al4V Joints Using Finite Element Analysis
NASA Astrophysics Data System (ADS)
Sharma, Ashutosh; Kee, Se Ho; Jung, Flora; Heo, Yongku; Jung, Jae Pil
2016-05-01
This study aims to synthesize and evaluate the compressive strength of the ZrO2/Ti-6Al-4V joint brazed using an active metal filler Ag-Cu-Sn-Ti, and its application to dental implants assuring its reliability to resist the compressive failure in the actual oral environment. The brazing was performed at a temperature of 750 °C for 30 min in a vacuum furnace under 5 × 10-6 Torr atmosphere. The microstructure of the brazed joint showed the presence of an Ag-rich matrix and a Cu-rich phase, and Cu-Ti intermetallic compounds were observed along the Ti-6Al-4V bonded interface. The compressive strength of the brazed ZrO2/Ti-6Al-4V joint was measured by EN ISO 14801 standard test method. The measured compressive strength of the joint was ~1477 MPa—a value almost five times that of existing dental cements. Finite element analysis also confirmed the high von Mises stress values. The compressive strains in the samples were found concentrated near the Ti-6Al-4V position, matching with the position of the real fractured sample. These results suggest extremely significant compressive strength in ZrO2/Ti-6Al-4V joints using the Ag-Cu-Sn-Ti filler. It is believed that a highly reliable dental implant can be processed and designed using the results of this study.
Electroencephalogram–Electromyography Coupling Analysis in Stroke Based on Symbolic Transfer Entropy
Gao, Yunyuan; Ren, Leilei; Li, Rihui; Zhang, Yingchun
2018-01-01
The coupling strength between electroencephalogram (EEG) and electromyography (EMG) signals during motion control reflects the interaction between the cerebral motor cortex and muscles. Therefore, neuromuscular coupling characterization is instructive in assessing motor function. In this study, to overcome the limitation of losing the characteristics of signals in conventional time series symbolization methods, a variable scale symbolic transfer entropy (VS-STE) analysis approach was proposed for corticomuscular coupling evaluation. Post-stroke patients (n = 5) and healthy volunteers (n = 7) were recruited and participated in various tasks (left and right hand gripping, elbow bending). The proposed VS-STE was employed to evaluate the corticomuscular coupling strength between the EEG signal measured from the motor cortex and EMG signal measured from the upper limb in both the time-domain and frequency-domain. Results showed a greater strength of the bi-directional (EEG-to-EMG and EMG-to-EEG) VS-STE in post-stroke patients compared to healthy controls. In addition, the strongest EEG–EMG coupling strength was observed in the beta frequency band (15–35 Hz) during the upper limb movement. The predefined coupling strength of EMG-to-EEG in the affected side of the patient was larger than that of EEG-to-EMG. In conclusion, the results suggested that the corticomuscular coupling is bi-directional, and the proposed VS-STE can be used to quantitatively characterize the non-linear synchronization characteristics and information interaction between the primary motor cortex and muscles. PMID:29354091
Kim, Beom-Su; Yang, Sun-Sik; Park, Ho; Lee, Se-Hwan; Cho, Young-Sam; Lee, Jun
2017-09-01
Powder-based three-dimensional (3D) printing is an excellent method to fabricate complex-shaped scaffolds for tissue engineering. However, their lower mechanical strength restricts their application in bone tissue engineering. Here, we created a 3D-printed scaffold coated with a ε-polycaprolactone (PCL) polymer solution (5 and 10 w/v %) to improve the mechanical strength of the scaffold. The 3D scaffold was fabricated from calcium sulfate hemihydrate powder (CaSO 4 -1/2 H 2 O), transformed into hydroxyapatite (HAp) by treatment with a hydrothermal reaction in an NH 4 H 2 PO 4 solution. The surface properties and composition of the scaffold were evaluated using scanning electron microscopy and X-ray diffraction analysis. We demonstrated that the 3D scaffold coated with PCL had an improved mechanical modulus. Coating with 5 and 10% PCL increased the compressive strength significantly, by about 2-fold and 4-fold, respectively, compared with that of uncoated scaffolds. However, the porosity was reduced significantly by coating with 10% PCL. In vitro biological evaluation demonstrated that MG-63 cells adhered well and proliferated on the 3D scaffold coated with PCL, and the scaffold was not cytotoxic. In addition, alkaline phosphatase activity and real time polymerase chain reaction demonstrated that osteoblast differentiation also improved in the PCL-coated 3D scaffolds. These results indicated that PCL polymer coating could improve the compressive strength and biocompatibility of 3D HAp scaffolds for bone tissue engineering applications.
Bhatia, Hind P; Sood, Shveta; Sharma, Naresh
2017-01-01
Aim To evaluate and compare the sorption, solubility, and compressive strength of three different glass ionomer cements in artificial saliva - type IX glass ionomer cement, silver-reinforced glass ionomer cement, and zirconia-reinforced glass ionomer cement, so as to determine the material of choice for stress-bearing areas. Materials and methods A total of 90 cylindrical specimens (4 mm diameter and 6 mm height) were prepared for each material following the manufacturer’s instructions. After subjecting the specimens to thermocycling, 45 specimens were immersed in artificial saliva for 24 hours for compressive strength testing under a universal testing machine, and the other 45 were evaluated for sorption and solubility, by first weighing them by a precision weighing scale (W1), then immersing them in artificial saliva for 28 days and weighing them (W2), and finally dehydrating in an oven for 24 hours and weighing them (W3). Results Group III (zirconomer) shows the highest compressive strength followed by group II (Miracle Mix) and least compressive strength is seen in group I (glass ionomer cement type IX-Extra) with statistically significant differences between the groups. The sorption and solubility values in artificial saliva were highest for glass ionomer cement type IX - Extra-GC (group I) followed by zirconomer-Shofu (group III), and the least value was seen for Miracle Mix-GC (group II). Conclusion Zirconia-reinforced glass ionomer cement is a promising dental material and can be used as a restoration in stress-bearing areas due to its high strength and low solubility and sorption rate. It may be a substitute for silver-reinforced glass ionomer cement due to the added advantage of esthetics. Clinical significance This study provides vital information to pediatric dental surgeons on relatively new restorative materials as physical and mechanical properties of the new material are compared with conventional materials to determine the best suited material in terms of durability, strength and dimensional stability. This study will boost confidence among dental surgeons in terms of handling characteristics, cost effectiveness and success rate. This study will help clinically and scientifically; pediatric dental surgeons to use this material in stress-bearing areas in pediatric patients. How to cite this article Bhatia HP, Singh S, Sood S, Sharma N. A Comparative Evaluation of Sorption, Solubility, and Com-pressive Strength of Three Different Glass Ionomer Cements in Artificial Saliva: An in vitro Study. Int J Clin Pediatr Dent 2017;10(1):49-54. PMID:28377656
Lech, Osvandré; Piluski, Paulo; Tambani, Renato; Castro, Nero; Pimentel, Gilnei
2015-01-01
Objective: To evaluate the integrity of the subscapularis tendon by strength, function and magnetic resonance imaging after deltopectoralis access for anterior shoulder instability. Methods: 20 patients with anterior shoulder instability have been evaluated. Minimum follow-up was 12 months, with a mean of 40 months. Only male patients were included, with a mean of age of 29 years (20 − 42 years). The patients have been submitted to physical examinations of mobility, muscular strength, Belly Test and Gerber Test. The isokinetic strength in internal and external rotation, in angular speeds of 600/s and 1800/s, for both shoulders was measured using a dynamometer. In 15 patients magnetic resonance imaging (MRI) was carried out on both shoulders for evaluating the thickness, cross-sectional area and atrophy of the subscapularis muscle. Results: A significant difference was found between torque peaks at the speed of 600/s for internal (p=0.036) and external (p=0.008) rotation. However, at 1800/s the opposite happens (internal rotation: p=0.133; external rotation: p=0.393). Subscapularis muscle thickness and area are significantly smaller than the normal side, with a deficit of 19% and 23%, respectively. According to Rowe and UCLA scores, we find excellent and good results for the majority of patients, with a mean of 88 and 31.6 points, respectively. Conclusion: Despite of the good functional results, open surgery can limit strength and reduce the thickness and the cross-sectional area of subscapularis muscle. However, the best results were found in the patients who had the dominant side operated. PMID:27004190
A new evaluation tool to obtain practice-based evidence of worksite health promotion programs.
Dunet, Diane O; Sparling, Phillip B; Hersey, James; Williams-Piehota, Pamela; Hill, Mary D; Hanssen, Carl; Lawrenz, Frances; Reyes, Michele
2008-10-01
The Centers for Disease Control and Prevention developed the Swift Worksite Assessment and Translation (SWAT) evaluation method to identify promising practices in worksite health promotion programs. The new method complements research studies and evaluation studies of evidence-based practices that promote healthy weight in working adults. We used nationally recognized program evaluation standards of utility, feasibility, accuracy, and propriety as the foundation for our 5-step method: 1) site identification and selection, 2) site visit, 3) post-visit evaluation of promising practices, 4) evaluation capacity building, and 5) translation and dissemination. An independent, outside evaluation team conducted process and summative evaluations of SWAT to determine its efficacy in providing accurate, useful information and its compliance with evaluation standards. The SWAT evaluation approach is feasible in small and medium-sized workplace settings. The independent evaluation team judged SWAT favorably as an evaluation method, noting among its strengths its systematic and detailed procedures and service orientation. Experts in worksite health promotion evaluation concluded that the data obtained by using this evaluation method were sufficient to allow them to make judgments about promising practices. SWAT is a useful, business-friendly approach to systematic, yet rapid, evaluation that comports with program evaluation standards. The method provides a new tool to obtain practice-based evidence of worksite health promotion programs that help prevent obesity and, more broadly, may advance public health goals for chronic disease prevention and health promotion.
Nasseri, Ehsan Baradaran; Majidinia, Sara; Sharbaf, Davood Aghasizadeh
2017-05-01
Based on the frequent application of composite resins as tooth-colored fillings, this method is considered a viable alternative to dental amalgam. However, this method has the low bond strength of the composite to dentin. To solve this issue, various dental adhesive systems with different characteristics have been developed by dentistry experts. To assess the effect of an additional layer of unfilled resin in self-etch and total-etch dentin adhesives on the shear bond strength (SBS) of composite to dentin. Moreover, we assessed the effects of sample storage in artificial saliva on the SBS of composite to dentin. Methods: This experimental study was conducted on 160 freshly extracted human first or second premolar teeth, which were randomly divided into 16 groups. The teeth were prepared from Mashhad University of Medical Sciences, Mashhad, Iran (2008-2009). Scotchbond Multi-purpose (SBMP), single bond (SB), Clearfil SE Bond, and Clearfil S3 Bond were applied to dentin surface with or without the placement of hydrophobic resin (Margin Bond) in accordance with the instructions of the manufacturers. To expose the coronal dentin, the teeth were abraded with 600 grit SiC paper. Immediately after restoration, half of the samples were tested in terms of SBS, while the other samples were evaluated in terms of SBS after three months of storage in artificial saliva. SBS rates of dental composites evaluated by universal testing machine and samples were studied by optical stereomicroscopy to verify the failure type. Data analysis was performed in SPSS V.16 using Kolmogorov-Smirnov test, independent-samples t-test, ANOVA, and Duncan's logistic regression test. In this study, a significant reduction was observed in the SBS rates of SB and S3 bond adhesive systems after storage with and without hydrophobic resin (p>0.000). Without storage in normal saline, a significant increase was observed in the SBS rate of the SE bond (p=0.013). In addition, SBS rate of SBMP significantly increased after storage with hydrophobic resin (p=0.001). Finally, the highest and lowest rates of SBS were observed in the SE and S3 bonds in all the experimental groups, respectively. The effects of using a hydrophobic resin layer on shear bond strength values seem to be effective. The mild self-etch adhesive exhibited the best resin-dentine bond strength after aging.
Using the reactive strength index modified to evaluate plyometric performance.
Ebben, William P; Petushek, Erich J
2010-08-01
The ability to develop force quickly is a requisite ability in most sports. The reactive strength index (RSI) has been developed as a measure of explosive strength and is derived by evaluating jump height divided by ground contact time during the depth jump (DJ). At present, the RSI is typically used to evaluate DJ performance, because it is the only plyometric exercise with an identifiable ground contact time. The purpose of this study was to introduce a modification of the RSI (RSImod) that can be used to evaluate the explosive power of any vertical plyometric exercise. This study will also assess the reliability of the RSImod, evaluate the RSImod of a variety of plyometric exercises, and examine gender differences. Twenty-six men and 23 women served as subjects. Subjects performed 3 repetitions for each of 5 plyometric exercises including the countermovement jump (CMJ), tuck jump, single-leg jump, squat jump, and dumbbell CMJ. Data were analyzed using a 2-way analysis of variance to evaluate differences in RSImod between the plyometric exercise and the interaction between plyometric exercise RSImod and gender. The analysis of RSImod revealed significant main effects for plyometric exercise type (p
Effect of recycling protocol on mechanical strength of used mini-implants.
Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira
2014-01-01
Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.
Integrative rehabilitation of elderly stroke survivors: The design and evaluation of the BrightArm™
Rabin, Bryan A.; Burdea, Grigore C.; Roll, Doru T.; Hundal, Jasdeep S.; Damiani, Frank; Pollack, Simcha
2011-01-01
Purpose To describe the development of the BrightArm upper extremity rehabilitation system, and to determine its clinical feasibility with older hemiplegic patients. Method The BrightArm adjusted arm gravity loading through table tilting. Patients wore an arm support that sensed grasp strength and communicated wirelessly with a personal computer. Games were written to improve cognitive, psychosocial and the upper extremity motor function and adapted automatically to each patient. The system underwent feasibility trials spanning 6 weeks. Participants were evaluated pre-therapy, post-therapy, and at 6 weeks follow-up using standardized clinical measures. Computerized measures of supported arm reach and game performance were stored on a remote server. Results Five participants had clinically significant improvements in their active range of shoulder movement, shoulder strength, grasp strength, and their ability to focus. Several participants demonstrated substantially higher arm function (measured with the Fugl-Meyer test) and two were less-depressed (measured with the Becks Depression Inventory, Second Edition). The BrightArm technology was well-accepted by the participants, who gave it an overall subjective rating of 4.1 on a 5 point Likert scale. Conclusions Given these preliminary findings, it will be beneficial to evaluate the BrightArm through controlled clinical trials and to investigate its application to other clinical populations. PMID:22107353
Evaluating Sleep Disturbance: A Review of Methods
NASA Technical Reports Server (NTRS)
Smith, Roy M.; Oyung, R.; Gregory, K.; Miller, D.; Rosekind, M.; Rosekind, Mark R. (Technical Monitor)
1996-01-01
There are three general approaches to evaluating sleep disturbance in regards to noise: subjective, behavioral, and physiological. Subjective methods range from standardized questionnaires and scales to self-report measures designed for specific research questions. There are two behavioral methods that provide useful sleep disturbance data. One behavioral method is actigraphy, a motion detector that provides an empirical estimate of sleep quantity and quality. An actigraph, worn on the non-dominant wrist, provides a 24-hr estimate of the rest/activity cycle. The other method involves a behavioral response, either to a specific probe or stimuli or subject initiated (e.g., indicating wakefulness). The classic, gold standard for evaluating sleep disturbance is continuous physiological monitoring of brain, eye, and muscle activity. This allows detailed distinctions of the states and stages of sleep, awakenings, and sleep continuity. Physiological delta can be obtained in controlled laboratory settings and in natural environments. Current ambulatory physiological recording equipment allows evaluation in home and work settings. These approaches will be described and the relative strengths and limitations of each method will be discussed.
Investigation of Mechanical Properties and Fracture Simulation of Solution-Treated AA 5754
NASA Astrophysics Data System (ADS)
Kumar, Pankaj; Singh, Akhilendra
2017-10-01
In this work, mechanical properties and fracture toughness of as-received and solution-treated aluminum alloy 5754 (AA 5754) are experimentally evaluated. Solution heat treatment of the alloy is performed at 530 °C for 2 h, and then, quenching is done in water. Yield strength, ultimate tensile strength, impact toughness, hardness, fatigue life, brittle fracture toughness (K_{Ic} ) and ductile fracture toughness (J_{Ic} ) are evaluated for as-received and solution-treated alloy. Extended finite element method has been used for the simulation of tensile and fracture behavior of material. Heaviside function and asymptotic crack tip enrichment functions are used for modelling of the crack in the geometry. Ramberg-Osgood material model coupled with fracture energy is used to simulate the crack propagation. Fracture surfaces obtained from various mechanical tests are characterized by scanning electron microscopy.
The improvement of adhesive properties of PEEK through different pre-treatments
NASA Astrophysics Data System (ADS)
Hallmann, Lubica; Mehl, Albert; Sereno, Nuno; Hämmerle, Christoph H. F.
2012-07-01
The purpose of this in vitro study was the evaluation of the bond strength of the adhesives/composite resin to Poly Ether Ether Ketone (PEEK) based dental polymer after using different surface conditioning methods. PEEK blanks were cut into discs. All disc specimens were polished with 800 grit SiC paper and divided into 6 main groups. Main groups were divided into 2 subgroups. The main groups of 32 specimens each were treated as follow: (1) control specimens (no treatment), (2) piranha solution etching, (3) abraded with 50 μm alumina particles and chemical etching, (4) abraded with 110 μm alumina particles and chemical etching, (5) abraded with 30 μm silica-coated alumina particles and chemical etching, (6) abraded with 110 μm silica-coated alumina particles and chemical etching. Plexiglas tubes filled with a composite resin (RelyX Unicem) were bonded to the specimens. The adhesives used were Heliobond and Clearfil Ceramic Primer. Each specimen was stored in distilled water (37 °C) for 3 days. Tensile bond strength was measured in a universal testing machine and failure methods were evaluated. Abraded surface with 50 μm alumina particles followed by etching with piranha solution lead to the highest bond strength of 21.4 MPa when Heliobond like adhesive was used. Tribochemical silica coated/etched PEEK surfaces did not have an effect on the bond strength. Non-treated PEEK surface was not able to establish a bond with composite resin. The proper choice of adhesive/composite resin system leads to a strong bond. ConclusionAirborne particle abrasion in combination with piranha solution etching improves the adhesive properties of PEEK.
Analysis of local warm forming of high strength steel using near infrared ray energy
NASA Astrophysics Data System (ADS)
Yang, W. H.; Lee, K.; Lee, E. H.; Yang, D. Y.
2013-12-01
The automotive industry has been pressed to satisfy more rigorous fuel efficiency requirements to promote energy conservation, safety features and cost containment. To satisfy this need, high strength steel has been developed and used for many different vehicle parts. The use of high strength steels, however, requires careful analysis and creativity in order to accommodate its relatively high springback behavior. An innovative method, called local warm forming with near infrared ray, has been developed to help promote the use of high strength steels in sheet metal forming. For this method, local regions of the work piece are heated using infrared ray energy, thereby promoting the reduction of springback behavior. In this research, a V-bend test is conducted with DP980. After springback, the bend angles for specimens without local heating are compared to those with local heating. Numerical analysis has been performed using the commercial program, DEFORM-2D. This analysis is carried out with the purpose of understanding how changes to the local stress distribution will affect the springback during the unloading process. The results between experimental and computational approaches are evaluated to assure the accuracy of the simulation. Subsequent numerical simulation studies are performed to explore best practices with respect to thermal boundary conditions, timing, and applicability to the production environment.
The effect of silica-coating by sol-gel process on resin-zirconia bonding.
Lung, Christie Ying Kei; Kukk, Edwin; Matinlinna, Jukka Pekka
2013-01-01
The effect of silica-coating by sol-gel process on the bond strength of resin composite to zirconia was evaluated and compared against the sandblasting method. Four groups of zirconia samples were silica-coated by sol-gel process under varied reagent ratios of ethanol, water, ammonia and tetraethyl orthosilicate and for different deposition times. One control group of zirconia samples were treated with sandblasting. Within each of these five groups, one subgroup of samples was kept in dry storage while another subgroup was aged by thermocycling for 6,000 times. Besides shear bond testing, the surface topography and surface elemental composition of silica-coated zirconia samples were also examined using scanning electron microscopy and X-ray photoelectron spectroscopy. Comparison of silica coating methods revealed significant differences in bond strength among the Dry groups (p<0.001) and Thermocycled groups (p<0.001). Comparison of sol-gel deposition times also revealed significant differences in bond strength among the Dry groups (p<0.01) and Thermocycled groups (p<0.001). Highest bond strengths were obtained after 141-h deposition: Dry (7.97±3.72 MPa); Thermocycled (2.33±0.79 MPa). It was concluded that silica-coating of zirconia by sol-gel process resulted in weaker resin bonding than by sandblasting.
Friction Stir Weld Restart+Reweld Repair Allowables
NASA Technical Reports Server (NTRS)
Clifton, Andrew
2008-01-01
A friction stir weld (FSW) repair method has been developed and successfully implemented on Al 2195 plate material for the Space Shuttle External Fuel Tank (ET). The method includes restarting the friction stir weld in the termination hole of the original weld followed by two reweld passes. Room temperature and cryogenic temperature mechanical properties exceeded minimum FSW design strength and compared well with the development data. Simulated service test results also compared closely to historical data for initial FSW, confirming no change to the critical flaw size or inspection requirements for the repaired weld. Testing of VPPA fusion/FSW intersection weld specimens exhibited acceptable strength and exceeded the minimum design value. Porosity, when present at the intersection was on the root side toe of the fusion weld, the "worst case" being 0.7 inch long. While such porosity may be removed by sanding, this "worst case" porosity condition was tested "as is" and demonstrated that porosity did not negatively affect the strength of the intersection weld. Large, 15-inch "wide panels" FSW repair welds were tested to demonstrate strength and evaluate residual stresses using photo stress analysis. All results exceeded design minimums, and photo stress analysis showed no significant stress gradients due to the presence of the restart and multi-pass FSW repair weld.
[Application of sintered Ti powder to dental prostheses].
Hikosaka, Tatsuya; Tanaka, Yoshinobu; Hoshiai, Kazumoto; Kanazawa, Takeshi; Nakamura, Yoshinori; Tsuda, Kenji; Ohasi, Hideya
2005-04-01
Powder metallurgy is a metal processing technology. Porous titanium produced from powder is widely used. The method is applied to titanium, which is not easy to cast as it sinters under melting point. In prosthetic dentistry, powder metallurgy can be applied to high fusing metal that is biocompatible. In this study, we examined the mechanical characteristics of the Ti sheet produced by sintering and discussed its application to dental prosthesis manufacturing. Ti sheets of 1-mm thickness, in which a binder was added to spherical Ti powder, were produced with the Doctor Blade Method. The sintering was carried out between 900-1150 degrees C at 6 temperatures. The sintered compact was evaluated by dimensional change rate, hardness test, bending strength, tensile strength and SEM observation. Another compact was sintered on the refractory cast. Mechanical strength significantly increased with sintering temperature. In addition, excellent mechanical strength was acquired by adding crushed powder and performing the de-binder process. In the sintering on the refractory cast, pre-baking for more than 100 minutes and sintering at over 1050 degrees C was needed for practical application. It thus seems possible to apply sintered titanium to dental prostheses. However, it will be necessary to examine the control of the shrinkage of the sintered compact in the future too.
Bonding between oxide ceramics and adhesive cement systems: a systematic review.
Papia, Evaggelia; Larsson, Christel; du Toit, Madeleine; Vult von Steyern, Per
2014-02-01
The following aims were set for this systematic literature review: (a) to make an inventory of existing methods to achieve bondable surfaces on oxide ceramics and (b) to evaluate which methods might provide sufficient bond strength. Current literature of in vitro studies regarding bond strength achieved using different surface treatments on oxide ceramics in combination with adhesive cement systems was selected from PubMed and systematically analyzed and completed with reference tracking. The total number of publications included for aim a was 127 studies, 23 of which were used for aim b. The surface treatments are divided into seven main groups: as-produced, grinding/polishing, airborne particle abrasion, surface coating, laser treatment, acid treatment, and primer treatment. There are large variations, making comparison of the studies difficult. An as-produced surface of oxide ceramic needs to be surface treated to achieve durable bond strength. Abrasive surface treatment and/or silica-coating treatment with the use of primer treatment can provide sufficient bond strength for bonding oxide ceramics. This conclusion, however, needs to be confirmed by clinical studies. There is no universal surface treatment. Consideration should be given to the specific materials to be cemented and to the adhesive cement system to be used. Copyright © 2013 Wiley Periodicals, Inc.
Experimental study of assistant aids and new nursing method in nursing care work.
Motegi, Nobuyuki; Matsuda, Fumiko; Takeuchi, Yuriko; Misawa, Tetsuo
2012-01-01
This study seeks to evaluate the effect of regular and new nursing methods in nursing care work. Nursing care work often causes low back pain in nursing care worker. The principle of not lifting when transferring patients has been proposed as one way to prevent low back pain. This principle incorporates the use of the patient's strength and assistant aids. A sliding seats and transfer boards have been proposed as assistant aids for the transferring patients. It is necessary to evaluate the effectiveness of these assistant aids in preventing low back pain. Ten subjects performed two tasks in this experiment. Five were nursing experienced persons and five were the inexperienced. EMG results indicated that the new nursing method was less stressful than the methods. A questionnaire revealed that the new method was evaluated more highly than the regular method. Based on these results, we propose that a sliding seats and transfer boards be used in nursing care work.
NASA Astrophysics Data System (ADS)
Kang, Chao; Shi, Yaoyao; He, Xiaodong; Yu, Tao; Deng, Bo; Zhang, Hongji; Sun, Pengcheng; Zhang, Wenbin
2017-09-01
This study investigates the multi-objective optimization of quality characteristics for a T300/epoxy prepreg tape-wound cylinder. The method integrates the Taguchi method, grey relational analysis (GRA) and response surface methodology, and is adopted to improve tensile strength and reduce residual stress. In the winding process, the main process parameters involving winding tension, pressure, temperature and speed are selected to evaluate the parametric influences on tensile strength and residual stress. Experiments are conducted using the Box-Behnken design. Based on principal component analysis, the grey relational grades are properly established to convert multi-responses into an individual objective problem. Then the response surface method is used to build a second-order model of grey relational grade and predict the optimum parameters. The predictive accuracy of the developed model is proved by two test experiments with a low prediction error of less than 7%. The following process parameters, namely winding tension 124.29 N, pressure 2000 N, temperature 40 °C and speed 10.65 rpm, have the highest grey relational grade and give better quality characteristics in terms of tensile strength and residual stress. The confirmation experiment shows that better results are obtained with GRA improved by the proposed method than with ordinary GRA. The proposed method is proved to be feasible and can be applied to optimize the multi-objective problem in the filament winding process.
NASA Astrophysics Data System (ADS)
Sumiya, H.; Hamaki, K.; Harano, K.
2018-05-01
Ultra-hard and high-strength spherical indenters with high precision and sphericity were successfully prepared from nanopolycrystalline diamond (NPD) synthesized by direct conversion sintering from graphite under high pressure and high temperature. It was shown that highly accurate and stable microfracture strength tests can be performed on various super-hard diamond materials by using the NPD spherical indenters. It was also verified that this technique enables quantitative evaluation of the strength characteristics of single crystal diamonds and NPDs which have been quite difficult to evaluate.
Bond Strength of Composite CFRP Reinforcing Bars in Timber
Corradi, Marco; Righetti, Luca; Borri, Antonio
2015-01-01
The use of near-surface mounted (NSM) fibre-reinforced polymer (FRP) bars is an interesting method for increasing the shear and flexural strength of existing timber members. This article examines the behaviour of carbon FRP (CFRP) bars in timber under direct pull-out conditions. The objective of this experimental program is to investigate the bond strength between composite bars and timber: bars were epoxied into small notches made into chestnut and fir wood members using a commercially-available epoxy system. Bonded lengths varied from 150 to 300 mm. Failure modes, stress and strain distributions and the bond strength of CFRP bars have been evaluated and discussed. The pull-out capacity in NSM CFRP bars at the onset of debonding increased with bonded length up to a length of 250 mm. While CFRP bar’s pull-out was achieved only for specimens with bonded lengths of 150 and 200 mm, bar tensile failure was mainly recorded for bonded lengths of 250 and 300 mm. PMID:28793423
Strength and fatigue properties of three-step sintered dense nanocrystal hydroxyapatite bioceramics
NASA Astrophysics Data System (ADS)
Guo, Wen-Guang; Qiu, Zhi-Ye; Cui, Han; Wang, Chang-Ming; Zhang, Xiao-Jun; Lee, In-Seop; Dong, Yu-Qi; Cui, Fu-Zhai
2013-06-01
Dense hydroxyapatite (HA) ceramic is a promising material for hard tissue repair due to its unique physical properties and biologic properties. However, the brittleness and low compressive strength of traditional HA ceramics limited their applications, because previous sintering methods produced HA ceramics with crystal sizes greater than nanometer range. In this study, nano-sized HA powder was employed to fabricate dense nanocrystal HA ceramic by high pressure molding, and followed by a three-step sintering process. The phase composition, microstructure, crystal dimension and crystal shape of the sintered ceramic were examined by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Mechanical properties of the HA ceramic were tested, and cytocompatibility was evaluated. The phase of the sintered ceramic was pure HA, and the crystal size was about 200 nm. The compressive strength and elastic modulus of the HA ceramic were comparable to human cortical bone, especially the good fatigue strength overcame brittleness of traditional sintered HA ceramics. Cell attachment experiment also demonstrated that the ceramics had a good cytocompatibility.
Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori
2015-01-01
In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.
Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint
Lee, Sang-Yeob
2010-01-01
PURPOSE The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm. PMID:21264189
An Annotated Bibliography of Isotonic Weight-Training Methods.
ERIC Educational Resources Information Center
Wysong, John V.
This literature study was conducted to compare and evaluate various types and techniques of weight lifting so that a weight lifting program could be selected or devised for a secondary school. Annotations of 32 research reports, journal articles, and monographs on isotonic strength training are presented. The literature in the first part of the…
Basic Movement Activities. Perceptual Motor Development. Book 1.
ERIC Educational Resources Information Center
Capon, Jack J.
This textbook on basic movement activities for children in the primary grades is divided into two sections. The first section presents methods of evaluating the physical strengths and weaknesses of individual children. The seven tests outlined and illustrated provide the teacher with the means for assessing each child's abilities and potential for…
ERIC Educational Resources Information Center
Educational Products Information Exchange Inst., Stony Brook, NY.
Learner Verification and Revision (LVR) Process of Instructional Materials is an ongoing effort for the improvement of instructional materials based on systematic feedback from learners who have used the materials. This evaluation gives publishers a method of identifying instructional strengths and weaknesses of a product and provides an…
Molecular Docking of Enzyme Inhibitors: A Computational Tool for Structure-Based Drug Design
ERIC Educational Resources Information Center
Rudnitskaya, Aleksandra; Torok, Bela; Torok, Marianna
2010-01-01
Molecular docking is a frequently used method in structure-based rational drug design. It is used for evaluating the complex formation of small ligands with large biomolecules, predicting the strength of the bonding forces and finding the best geometrical arrangements. The major goal of this advanced undergraduate biochemistry laboratory exercise…
Durability of adhesives in plywood
Robert H. Gillespie; Bryan H. River
1976-01-01
Seven different adhesives were evaluated for durability as plywood adhesives by exposing panels and shear-test specimens to weathering at the Madison exposure site for nearly 8 years. Wet-strength loss and wood-failure changes were measured as a function of exposure time. The method of exposure accelerated the degradation that would have resulted from exposure in most...
A case study of multi-seam coal mine entry stability analysis with strength reduction method
Tulu, Ihsan Berk; Esterhuizen, Gabriel S; Klemetti, Ted; Murphy, Michael M.; Sumner, James; Sloan, Michael
2017-01-01
In this paper, the advantage of using numerical models with the strength reduction method (SRM) to evaluate entry stability in complex multiple-seam conditions is demonstrated. A coal mine under variable topography from the Central Appalachian region is used as a case study. At this mine, unexpected roof conditions were encountered during development below previously mined panels. Stress mapping and observation of ground conditions were used to quantify the success of entry support systems in three room-and-pillar panels. Numerical model analyses were initially conducted to estimate the stresses induced by the multiple-seam mining at the locations of the affected entries. The SRM was used to quantify the stability factor of the supported roof of the entries at selected locations. The SRM-calculated stability factors were compared with observations made during the site visits, and the results demonstrate that the SRM adequately identifies the unexpected roof conditions in this complex case. It is concluded that the SRM can be used to effectively evaluate the likely success of roof supports and the stability condition of entries in coal mines. PMID:28239503
A case study of multi-seam coal mine entry stability analysis with strength reduction method.
Tulu, Ihsan Berk; Esterhuizen, Gabriel S; Klemetti, Ted; Murphy, Michael M; Sumner, James; Sloan, Michael
2016-03-01
In this paper, the advantage of using numerical models with the strength reduction method (SRM) to evaluate entry stability in complex multiple-seam conditions is demonstrated. A coal mine under variable topography from the Central Appalachian region is used as a case study. At this mine, unexpected roof conditions were encountered during development below previously mined panels. Stress mapping and observation of ground conditions were used to quantify the success of entry support systems in three room-and-pillar panels. Numerical model analyses were initially conducted to estimate the stresses induced by the multiple-seam mining at the locations of the affected entries. The SRM was used to quantify the stability factor of the supported roof of the entries at selected locations. The SRM-calculated stability factors were compared with observations made during the site visits, and the results demonstrate that the SRM adequately identifies the unexpected roof conditions in this complex case. It is concluded that the SRM can be used to effectively evaluate the likely success of roof supports and the stability condition of entries in coal mines.
A SWOT analysis of the organization and financing of the Danish health care system.
Christiansen, Terkel
2002-02-01
The organization and financing of the Danish health care system was evaluated within a framework of a SWOT analysis (analysis of Strengths, Weaknesses, Opportunities and Threats) by a panel of five members with a background in health economics. The present paper describes the methods and materials used for the evaluation: selection of panel members, structure of the evaluation task according to the health care triangle model, selection of background material consisting of documents and literature on the Danish health care system, and a 1-week study visit.
Functional modules by relating protein interaction networks and gene expression.
Tornow, Sabine; Mewes, H W
2003-11-01
Genes and proteins are organized on the basis of their particular mutual relations or according to their interactions in cellular and genetic networks. These include metabolic or signaling pathways and protein interaction, regulatory or co-expression networks. Integrating the information from the different types of networks may lead to the notion of a functional network and functional modules. To find these modules, we propose a new technique which is based on collective, multi-body correlations in a genetic network. We calculated the correlation strength of a group of genes (e.g. in the co-expression network) which were identified as members of a module in a different network (e.g. in the protein interaction network) and estimated the probability that this correlation strength was found by chance. Groups of genes with a significant correlation strength in different networks have a high probability that they perform the same function. Here, we propose evaluating the multi-body correlations by applying the superparamagnetic approach. We compare our method to the presently applied mean Pearson correlations and show that our method is more sensitive in revealing functional relationships.
Functional modules by relating protein interaction networks and gene expression
Tornow, Sabine; Mewes, H. W.
2003-01-01
Genes and proteins are organized on the basis of their particular mutual relations or according to their interactions in cellular and genetic networks. These include metabolic or signaling pathways and protein interaction, regulatory or co-expression networks. Integrating the information from the different types of networks may lead to the notion of a functional network and functional modules. To find these modules, we propose a new technique which is based on collective, multi-body correlations in a genetic network. We calculated the correlation strength of a group of genes (e.g. in the co-expression network) which were identified as members of a module in a different network (e.g. in the protein interaction network) and estimated the probability that this correlation strength was found by chance. Groups of genes with a significant correlation strength in different networks have a high probability that they perform the same function. Here, we propose evaluating the multi-body correlations by applying the superparamagnetic approach. We compare our method to the presently applied mean Pearson correlations and show that our method is more sensitive in revealing functional relationships. PMID:14576317
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorynin, I.V.; Filatov, V.M.; Ignatov, V.A.
1986-07-01
The authors examine data on the effect of defects on the fracture resistance of high-pressure vessels and their models obtained within the framework of the HSST program. Results of internal-pressure tests of two types of vessels with a wall thickness of 152 mm made from forgings of steels SA508 and SA533, as well as small vessels with a wall thickness of 11.5 and 23mm made of steel SA533 are shown. The authors state that testing thick-walled welded high-pressure vessels and thin-walled vessels with surface defects of different sizes has demonstrated that there are substantial static-strength reserves in structures designed bymore » existing domestic and foreign standards on the strength of power-plant equipment. A correction was proposed for the presently used method of calculating the resistance of highpressure vessels to brittle fracture that allows for the dimensions of the defects in relation to the type of vessel, the manufacturing technology, and the method of inspection.« less
Humidity effects on wire insulation breakdown strength.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Appelhans, Leah
2013-08-01
Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layermore » Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.« less
Kaith, B S; Jindal, R; Jana, A K; Maiti, M
2010-09-01
In this paper, corn starch based green composites reinforced with graft copolymers of Saccharum spontaneum L. (Ss) fiber and methyl methacrylates (MMA) and its mixture with acrylamide (AAm), acrylonitrile (AN), acrylic acid (AA) were prepared. Resorcinol-formaldehyde (Rf) was used as the cross-linking agent in corn starch matrix and different physico-chemical, thermal and mechanical properties were evaluated. The matrix and composites were found to be thermally more stable than the natural corn starch backbone. Further the matrix and composites were subjected for biodegradation studies through soil composting method. Different stages of biodegradation were evaluated through FT-IR and scanning electron microscopic (SEM) techniques. S. spontaneum L fiber-reinforced composites were found to exhibit better tensile strength. On the other hand Ss-g-poly (MMA) reinforced composites showed maximum compressive strength and wear resistance than other graft copolymers reinforced composite and the basic matrix. (c) 2010 Elsevier Ltd. All rights reserved.
Navimipour, Elmira Jafari; Oskoee, Siavash Savadi; Oskoee, Parnian Alizadeh; Bahari, Mahmoud; Rikhtegaran, Sahand; Ghojazadeh, Morteza
2012-03-01
Success in sandwich technique procedures can be achieved through an acceptable bond between the materials. The aim of this study was to compare the effect of 35% phosphoric acid and Er,Cr:YSGG laser on shear bond strength of conventional glass-ionomer cement (GIC) and resin-modified glass-ionomer cement (RMGIC) to composite resin in sandwich technique. Sixty-six specimens were prepared from each type of glass-ionomer cements and divided into three treatment groups as follows: without pretreatment, acid etching by 35% phosphoric acid for 15 s, and 1-W Er,Cr:YSGG laser treatment for 15 s with a 600-μm-diameter tip aligned perpendicular to the target area at a distance of 1 mm from the surface. Energy density of laser irradiation was 17.7 J/cm(2). Two specimens in each group were prepared for evaluation under a scanning electron microscope (SEM) after surface treatment and the remainder underwent bonding procedure with a bonding agent and composite resin. Then the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Two-factor analysis of variance and post-hoc Tukey test showed that the cement type, surface treatment method, and the interaction of these two factors significantly affect the shear bond strength between glass-ionomer cements and composite resin (p < 0.05). Surface treatment with phosphoric acid or Er,Cr:YSGG laser increased the shear bond strength of GIC to composite resin; however, in RMGIC only laser etching resulted in significantly higher bond strength. These findings were supported by SEM results. The fracture mode was evaluated under a stereomicroscope at ×20.
Tension fracture of laminates for transport fuselage. Part 2: Large notches
NASA Technical Reports Server (NTRS)
Walker, Tom H.; Ilcewicz, Larry B.; Polland, D. R.; Poe, C. C., Jr.
1993-01-01
Tests were conducted on over 200 center-crack specimens to evaluate: (a) the tension-fracture performance of candidate materials and laminates for commercial fuselage applications; and (b) the accuracy of several failure criteria in predicting response. Crack lengths of up to 12 inches were considered. Other variables included fiber/matrix combination, layup, lamination manufacturing process, and intraply hybridization. Laminates fabricated using the automated tow-placement process provided significantly higher tension-fracture strengths than nominally identical tape laminates. This confirmed earlier findings for other layups, and possibly relates to a reduced stress concentration resulting from a larger scale of repeatable material inhomogeneity in the tow-placed laminates. Changes in material and layup result in a trade-off between small-notch and large-notch strengths. Toughened resins and 0 deg-dominate layups result in higher small-notch strengths but lower large-notch strengths than brittle resins, 90 deg and 45 deg dominated layups, and intraply S2-glass hybrid material forms. Test results indicate that strength-prediction methods that allow for a reduced order singularity of the crack-tip stress field are more successful at predicting failure over a range of notch sizes than those relying on the classical square-root singularity. The order of singularity required to accurately predict large-notch strength from small-notch data was affected by both material and layup. Measured crack-tip strain distributions were generally higher than those predicted using classical methods. Traditional methods of correcting for finite specimen width were found to be lacking, confirming earlier findings with other specimen geometries. Fracture tests of two stiffened panels, identical except for differing materials, with severed central stiffeners resulted in nearly identical damage progression and failure sequences. Strain-softening laws implemented within finite element models appear attractive to account for load redistribution in configured structure due to damage-induced crack tip softening
Jerrold E. Winandy; Douglas Herdman
2003-01-01
The objective of this work was to evaluate the effects of a new boron-nitrogen, phosphate-free fire-retardant (FR) formulation on several mechanical properties of FR-treated wood and to assess the potential of this treatment for in-service thermal-induced strength loss resulting from exposure to high temperature. Fire-retardant-treated and untreated small clear...
Jerrold E. Winandy; Michael J. Richards
2003-01-01
The objective of this work was to evaluate (a) the effects of a new boronâ nitrogen, phosphate-free fire-retardant (FR) formulation on the initial strength of Douglas-fir AB-grade plywood and (b) the potential of this FR treatment to experience subsequent thermal degradation In-service when exposed to elevated temperatures. Test Method ASTM D 5516 was generally...
NDE detectability of fatigue type cracks in high strength alloys
NASA Technical Reports Server (NTRS)
Christner, B. K.; Rummel, W. D.
1983-01-01
Specimens suitable for investigating the reliability of production nondestructive evaluation (NDE) to detect tightly closed fatigue cracks in high strength alloys representative of those materials used in spacecraft engine/booster construction were produced. Inconel 718 was selected as representative of nickel base alloys and Haynes 188 was selected as representative of cobalt base alloys used in this application. Cleaning procedures were developed to insure the reusability of the test specimens and a flaw detection reliability assessment of the fluorescent penetrant inspection method was performed using the test specimens produced to characterize their use for future reliability assessments and to provide additional NDE flaw detection reliability data for high strength alloys. The statistical analysis of the fluorescent penetrant inspection data was performed to determine the detection reliabilities for each inspection at a 90% probability/95% confidence level.
Enhancing the compressive strength of landfill soil using cement and bagasse ash
NASA Astrophysics Data System (ADS)
Azim, M. A. M.; Azhar, A. T. S.; Tarmizi, A. K. A.; Shahidan, S.; Nabila, A. T. A.
2017-11-01
The stabilisation of contaminated soil with cement and agricultural waste is a widely applied method which contributes to the sustainability of the environment. Soil may be stabilised to increase strength and durability or to prevent erosion and other geotechnical failure. This study was carried out to evaluate the compressive strength of ex-landfill soil when cement and bagasse ash (BA) are added to it. Different proportions of cement (5%, 10%, 15% and 20%) was added to sample weights without BA. On the other hand, the cement in a different batch of sample weights was replaced by 2.5%, 5%, 7.5% and 10% of BA. All samples were allowed to harden and were cured at room temperature for 7, 14 and 28 days respectively. The strength of the contaminated soil was assessed using an unconfined compressive strength test (UCS). The laboratory tests also included the index properties of soil, cement and bagasse ash in raw form. The results indicated that the samples with cement achieved the highest compressive strength measuring 4.39 MPa. However, this study revealed that the use of bagasse ash produced low quality products with a reduction in strength. For example, when 5% of cement was replaced with 5% ash, the compressive strength decreased by about 54% from 0.72 MPa to 0.33 MPa. Similarly, the compressive strength of each sample after a curing period of 28 days was higher compared to samples cured for 7 and 14 days respectively. This is proved that a longer curing period is needed to increase the compressive strength of the samples.
NASA Astrophysics Data System (ADS)
Saito, S.; Lin, W.
2014-12-01
Core-log integration has been applied for rock mechanics studies in scientific ocean drilling since 2007 in plate subduction margins such as Nankai Trough, Costa Rica margin, and Japan Trench. State of stress in subduction wedge is essential for controlling dynamics of plate boundary fault. One of the common methods to estimate stress state is analysis of borehole breakouts (drilling induced borehole wall compressive failures) recorded in borehole image logs to determine the maximum horizontal principal stress orientation. Borehole breakouts can also yield possible range of stress magnitude based on a rock compressive strength criterion. In this study, we constrained the stress magnitudes based on two different rock failure criteria, the Mohr-Coulomb (MC) criteria and the modified Wiebols-Cook (mWC) criteria. As the MC criterion is the same as that under unconfined compression state, only one rock parameter, unconfined compressive strength (UCS) is needed to constrain stress magnitudes. The mWC criterion needs the UCS, Poisson's ratio and internal frictional coefficient determined by triaxial compression experiments to take the intermediate principal stress effects on rock strength into consideration. We conducted various strength experiments on samples taken during IODP Expeditions 334/344 (Costa Rica Seismogenesis Project) to evaluate reliable method to estimate stress magnitudes. Our results show that the effects of the intermediate principal stress on the rock compressive failure occurred on a borehole wall is not negligible.
Evaluation of punching shear strength of flat slabs supported on rectangular columns
NASA Astrophysics Data System (ADS)
Filatov, Valery
2018-03-01
The article presents the methodology and results of an analytical study of structural parameters influence on the value of punching force for the joint of columns and flat reinforced concrete slab. This design solution is typical for monolithic reinforced concrete girderless frames, which have a wide application in the construction of high-rise buildings. As the results of earlier studies show the punching shear strength of slabs at rectangular columns can be lower than at square columns with a similar length of the control perimeter. The influence of two structural parameters on the punching strength of the plate is investigated - the ratio of the side of the column cross-section to the effective depth of slab C/d and the ratio of the sides of the rectangular column Cmax/Cmin. According to the results of the study, graphs of reduction the control perimeter depending on the structural parameters are presented for columns square and rectangular cross-sections. Comparison of results obtained by proposed approach and MC2010 simplified method are shown, that proposed approach gives a more conservative estimate of the influence of the structural parameters. A significant influence of the considered structural parameters on punching shear strength of reinforced concrete slabs is confirmed by the results of experimental studies. The results of the study confirm the necessity of taking into account the considered structural parameters when calculating the punching shear strength of flat reinforced concrete slabs and further development of code design methods.
Odendaal, Willem; Atkins, Salla; Lewin, Simon
2016-12-15
Formative programme evaluations assess intervention implementation processes, and are seen widely as a way of unlocking the 'black box' of any programme in order to explore and understand why a programme functions as it does. However, few critical assessments of the methods used in such evaluations are available, and there are especially few that reflect on how well the evaluation achieved its objectives. This paper describes a formative evaluation of a community-based lay health worker programme for TB and HIV/AIDS clients across three low-income communities in South Africa. It assesses each of the methods used in relation to the evaluation objectives, and offers suggestions on ways of optimising the use of multiple, mixed-methods within formative evaluations of complex health system interventions. The evaluation's qualitative methods comprised interviews, focus groups, observations and diary keeping. Quantitative methods included a time-and-motion study of the lay health workers' scope of practice and a client survey. The authors conceptualised and conducted the evaluation, and through iterative discussions, assessed the methods used and their results. Overall, the evaluation highlighted programme issues and insights beyond the reach of traditional single methods evaluations. The strengths of the multiple, mixed-methods in this evaluation included a detailed description and nuanced understanding of the programme and its implementation, and triangulation of the perspectives and experiences of clients, lay health workers, and programme managers. However, the use of multiple methods needs to be carefully planned and implemented as this approach can overstretch the logistic and analytic resources of an evaluation. For complex interventions, formative evaluation designs including multiple qualitative and quantitative methods hold distinct advantages over single method evaluations. However, their value is not in the number of methods used, but in how each method matches the evaluation questions and the scientific integrity with which the methods are selected and implemented.
Waterson, Patrick; Robertson, Michelle M; Cooke, Nancy J; Militello, Laura; Roth, Emilie; Stanton, Neville A
2015-01-01
An important part of the application of sociotechnical systems theory (STS) is the development of methods, tools and techniques to assess human factors and ergonomics workplace requirements. We focus in this paper on describing and evaluating current STS methods for workplace safety, as well as outlining a set of six case studies covering the application of these methods to a range of safety contexts. We also describe an evaluation of the methods in terms of ratings of their ability to address a set of theoretical and practical questions (e.g. the degree to which methods capture static/dynamic aspects of tasks and interactions between system levels). The outcomes from the evaluation highlight a set of gaps relating to the coverage and applicability of current methods for STS and safety (e.g. coverage of external influences on system functioning; method usability). The final sections of the paper describe a set of future challenges, as well as some practical suggestions for tackling these. We provide an up-to-date review of STS methods, a set of case studies illustrating their use and an evaluation of their strengths and weaknesses. The paper concludes with a 'roadmap' for future work.
A novel tensile test method to assess texture and gaping in salmon fillets.
Ashton, Thomas J; Michie, Ian; Johnston, Ian A
2010-05-01
A new tensile strength method was developed to quantify the force required to tear a standardized block of Atlantic salmon muscle with the aim of identifying those samples more prone to factory downgrading as a result of softness and fillet gaping. The new method effectively overcomes problems of sample attachment encountered with previous tensile strength tests. The repeatability and sensitivity and predictability of the new technique were evaluated against other common instrumental texture measurement methods. The relationship between sensory assessments of firmness and parameters from the instrumental texture methods was also determined. Data from the new method were shown to have the strongest correlations with gaping severity (r =-0.514, P < 0.001) and the highest level of repeatability of data when analyzing cold-smoked samples. The Warner Bratzler shear method gave the most repeatable data from fresh samples and had the highest correlations between fresh and smoked product from the same fish (r = 0.811, P < 0.001). A hierarchical cluster analysis placed the tensile test in the top cluster, alongside the Warner Bratzler method, demonstrating that it also yields adequate data with respect to these tests. None of the tested sensory analysis attributes showed significant relationships to mechanical tests except fillet firmness, with correlations (r) of 0.42 for cylinder probe maximum force (P = 0.005) and 0.31 for tensile work (P = 0.04). It was concluded that the tensile test method developed provides an important addition to the available tools for mechanical analysis of salmon quality, particularly with respect to the prediction of gaping during factory processing, which is a serious commercial problem. A novel, reliable method of measuring flesh tensile strength in salmon, provides data of relevance to gaping.
Development of impact resistant boron/aluminum composites for turbojet engine fan blades
NASA Technical Reports Server (NTRS)
Melnyk, P.; Toth, I. J.
1975-01-01
Composite fabrication was performed by vacuum press diffusion bonding by both the foil-filament array and preconsolidated monotape methods. The effect of matrix material, fiber diameter, matrix enhancement, fiber volume reinforcement, test temperature, angle-plying, notch, impact orientation, processing variables and fabrication methods on tensile strength and Charpy impact resistance are evaluated. Root attachment concepts, were evaluated by room and elevated temperature tensile testing, as well as by pendulum-Izod and ballistic impact testing. Composite resistance to foreign object damage was also evaluated by ballistic impacting of panels using projectiles of gelatin, RTV rubber and steel at various velocities, and impingement angles. A significant improvement in the pendulum impact resistance of B-Al composites was achieved.
A laser-induced pulsed water jet for layer-selective submucosal dissection of the esophagus
Sato, C; Yamada, M; Nakagawa, A; Yamamoto, H; Fujishima, F; Tominaga, T; Satomi, S; Ohuchi, N
2016-01-01
Background and aims: Conventional water jet devices have been used for injecting fluid to lift up lesions during endoscopic submucosal dissection or endoscopic mucosal resection procedures. However, these devices cannot dissect the submucosal layer effectively. Here we aim to elucidate the dissection capability of a laser-induced pulsed water jet and to clarify the mechanism of dissection with layer selectivity. Materials (Subjects) and methods: Pulsed water jets were ejected from a stainless nozzle by accelerating saline using the energy of a pulsed holmium: yttrium-aluminum-garnet laser. The impact force (strength) of the jet was evaluated using a force meter. Injection of the pulsed jet into the submucosal layer was documented by high-speed imaging. The physical properties of the swine esophagus were evaluated by measuring the breaking strength. Submucosal dissection of the swine esophagus was performed and the resection bed was evaluated histologically. Results: Submucosal dissection of the esophagus was accomplished at an impact force of 1.11–1.47 N/pulse (laser energy: 1.1–1.5 J/pulse; standoff distance: 60 mm). Histological specimens showed clear dissection at the submucosal layer without thermal injury. The mean static breaking strength of the submucosa (0.11 ± 0.04 MPa) was significantly lower than that of the mucosa (1.32 ± 0.18 MPa), and propria muscle (1.45 ± 0.16 MPa). Conclusions: The pulsed water jet device showed potential for achieving selective submucosal dissection. It could achieve mucosal, submucosal, and muscle layer selectivity owing to the varied breaking strengths. PMID:27853343
Sharafeddin, Farahnaz; Shoale, Soodabe
2018-01-01
Statement of the Problem: The clinical success of ceramic depends on the quality of the bond between the zirconia and resin cement. Purpose: In the present study, the effects of universal and conventional MDP-containing primers were evaluated on the shear bond strength of zirconia ceramic and nanofilled composite resin. Materials and Method: Thirty blocks of zirconia ceramic (6mm×2mm) were prepared. Then the inner surfaces were air-abraded and divided into three groups (n= 10) as follows: untreated with primer (control group, I); All- Bond Universal (group II) and Z-Prime Plus (group III). The specimens in each group were bonded with Variolink N cement to cylinders of composite resin Z350XT. After 24 hour water storage, the shear bond strength test was performed with a universal testing machine at a crosshead speed of 1mm/ min and bond strength values (MPa) were calculated and analyzed with one-way ANOVA and post hoc Tukey tests (p< 0.05). The failure mode of each specimen was evaluated under a stereomicroscope and representative specimens were analyzed by scanning electron microscopy (SEM). Results: The mean shear bond strength values (MPa) were 7.58±1.62, 17.51±1.34 and 22.45±3.60 in groups I, II and III, respectively. These results indicated that the shear bond strength were significantly higher in groups II and III compared to the control group (p< 0.001). Chemical pre-treatment of zirconia with Z- Prime Plus revealed significantly higher bond strength than the All-Bond Universal adhesive (p< 0.002). All the failure modes were adhesive in the control group (I) and when using primer treatment, mixed failures occurred in 40% and 50% of specimens in groups II and III, respectively. Conclusion: Treatment with both primers resulted in higher bond strength values compared to the control group. The use of Z-Prime Plus treatment in combination with air-abrasion procedure resulted in the highest bond strength. PMID:29492416
Laser Shockwave Technique For Characterization Of Nuclear Fuel Plate Interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
James A. Smith; Barry H. Rabin; Mathieu Perton
2012-07-01
The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process.more » Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.« less
Laser shockwave technique for characterization of nuclear fuel plate interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perton, M.; Levesque, D.; Monchalin, J.-P.
2013-01-25
The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process.more » Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.« less
Fixation strength analysis of cup to bone material using finite element simulation
NASA Astrophysics Data System (ADS)
Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; van der Heide, Emile
2016-04-01
Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw inside of cup is effective; however, it has little effect in whole fixation. Therefore, an acetabular cup with good fixation, easy manufacture and easy installation is required. This paper is aiming at evaluating and proposing a new cup fixation design. To prove the strength of the present cup fixation design, the finite element simulation of three dimensional cup with new fixation design was performed. The present cup design was examined with twist axial and radial rotation. Results showed that the proposed cup design was better than the general version.
Nonlinear Fatigue Damage Model Based on the Residual Strength Degradation Law
NASA Astrophysics Data System (ADS)
Yongyi, Gao; Zhixiao, Su
In this paper, a logarithmic expression to describe the residual strength degradation process is developed in order to fatigue test results for normalized carbon steel. The definition and expression of fatigue damage due to symmetrical stress with a constant amplitude are also given. The expression of fatigue damage can also explain the nonlinear properties of fatigue damage. Furthermore, the fatigue damage of structures under random stress is analyzed, and an iterative formula to describe the fatigue damage process is deduced. Finally, an approximate method for evaluating the fatigue life of structures under repeated random stress blocking is presented through various calculation examples.
FEAMAC/CARES Stochastic-Strength-Based Damage Simulation Tool for Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Nemeth, Noel; Bednarcyk, Brett; Pineda, Evan; Arnold, Steven; Mital, Subodh; Murthy, Pappu; Bhatt, Ramakrishna
2016-01-01
Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MAC/GMC (Micromechanics Analysis Code/ Generalized Method of Cells) composite material analysis code. The resulting code is called FEAMAC/CARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMAC/CARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMAC/CARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.
Stochastic-Strength-Based Damage Simulation Tool for Ceramic Matrix Composite
NASA Technical Reports Server (NTRS)
Nemeth, Noel; Bednarcyk, Brett; Pineda, Evan; Arnold, Steven; Mital, Subodh; Murthy, Pappu
2015-01-01
Reported here is a coupling of two NASA developed codes: CARES (Ceramics Analysis and Reliability Evaluation of Structures) with the MAC/GMC (Micromechanics Analysis Code/ Generalized Method of Cells) composite material analysis code. The resulting code is called FEAMAC/CARES and is constructed as an Abaqus finite element analysis UMAT (user defined material). Here we describe the FEAMAC/CARES code and an example problem (taken from the open literature) of a laminated CMC in off-axis loading is shown. FEAMAC/CARES performs stochastic-strength-based damage simulation response of a CMC under multiaxial loading using elastic stiffness reduction of the failed elements.
Concepts and techniques for ultrasonic evaluation of material mechanical properties
NASA Technical Reports Server (NTRS)
Vary, A.
1980-01-01
Ultrasonic methods that can be used for material strength are reviewed. Emergency technology involving advanced ultrasonic techniques and associated measurements is described. It is shown that ultrasonic NDE is particularly useful in this area because it involves mechanical elastic waves that are strongly modulated by morphological factors that govern mechanical strength and also dynamic failure modes. These aspects of ultrasonic NDE are described in conjunction with advanced approaches and theoretical concepts for signal acquisition and analysis for materials characterization. It is emphasized that the technology is in its infancy and that much effort is still required before the techniques and concepts can be transferred from laboratory to field conditions.
Justification of indirect methods of bending stresses polyethylene pipes evaluation
NASA Astrophysics Data System (ADS)
Serebrennikov, A. A.; Serebrennikov, D. A.; Hakimov, Z. R.
2017-10-01
The world and Russian companies have a long experience of the polyethylene pipeline installation and operation. At the same time, the significant attention is paid to the improvement of the relevant machines and the production technology. The polyethylene pipeline installation experience proves that its operation properties (reliability and durability) depend on physical and mechanical characteristics of polyethylene, which should be saved during its installation. Defects can occur, including in cases when the pipe is subjected to the significant bending stresses during installation. To evaluate these stresses, including when exposed to cold weather conditions, an indirect method based on the relationship between strength characteristics and occurred deformations is proposed.
A novel surgical technique for a rat subcutaneous implantation of a tissue engineered scaffold
Khorramirouz, Reza; Go, Jason L.; Noble, Christopher; Jana, Soumen; Maxson, Eva; Lerman, Amir; Young, Melissa D.
2018-01-01
Objectives Subcutaneous implantations in small animal models are currently required for preclinical studies of acellular tissue to evaluate biocompatibility, including host recellularization and immunogenic reactivity. Methods Three rat subcutaneous implantation methods were evaluated in six Sprague Dawley rats. An acellular xenograft made from porcine pericardium was used as the tissue-scaffold. Three implantation methods were performed; 1) Suture method is where a tissue-scaffold was implanted by suturing its border to the external oblique muscle, 2) Control method is where a tissue-scaffold was implanted without any suturing or support, 3) Frame method is where a tissue-scaffold was attached to a circular frame composed of polycaprolactone (PCL) biomaterial and placed subcutaneously. After 1 and 4 weeks, tissue-scaffolds were explanted and evaluated by hematoxylin and eosin (H&E), Masson’s trichrome, Picrosirius Red, transmission electron microscopy (TEM), immunohistochemistry, and mechanical testing. Results Macroscopically, tissue-scaffold degradation with the suture method and tissue-scaffold folding with the control method were observed after 4 weeks. In comparison, the frame method demonstrated intact tissue scaffolds after 4 weeks. H&E staining showed progressive cell repopulation over the course of the experiment in all groups with acute and chronic inflammation observed in suture and control methods throughout the duration of the study. Immunohistochemistry quantification of CD3, CD 31, CD 34, CD 163, and αSMA showed a statistically significant differences between the suture, control and frame methods (P < 0.05) at both time points. The average tensile strength was 4.03 ± 0.49, 7.45 ± 0.49 and 5.72 ± 1.34 (MPa) after 1 week and 0.55 ± 0.26, 0.12 ± 0.03 and 0.41 ± 0.32 (MPa) after 4 weeks in the suture, control, and frame methods; respectively. TEM analysis showed an increase in inflammatory cells in both suture and control methods following implantation. Conclusion Rat subcutaneous implantation with the frame method was performed with success and ease. The surgical approach used for the frame technique was found to be the best methodology for in vivo evaluation of tissue engineered acellular scaffolds, where the frame method did not compromise mechanical strength, but it reduced inflammation significantly. PMID:29519681
Evaluation of the tensile strength of the human ureter - Preliminary results.
Shilo, Yaniv; Pichamuthu, Joseph E; Averch, Timothy D; Vorp, David A
2014-09-15
Introduction: Ureteral injuries such as avulsion are directly related to mechanical damage of the ureter. Understanding the tensile strength of this tissue may assist in prevention of iatrogenic injuries. Few published studies have looked at the mechanical properties of the animal ureter, and of those none have determined the tensile strength of the human ureter. Therefore, the purpose of this work was to determine the tensile strength of the human ureter. Materials and Methods: We harvested 11 human proximal ureters from patients who were undergoing nephrectomy for either kidney tumors or non-functioning kidney. The specimens were then cut into multiple circumferentially and longitudinally-oriented tissue strips for tensile testing. Strips were uniaxially stretched to failure in a tensile testing machine. The corresponding force and displacement were recorded. Finally, stress at failure was noted as the tensile strength of the sample. Circumferential tensile strength was also compared in the proximal and distal regions of the specimens. Results: The tensile strength of the ureter in circumferential and longitudinal orientations was found to be 457.52±33.74 Ncm-2 and 902.43±122.08 Ncm-2, respectively (p<0.001). The circumferential strength in the proximal portion of the ureter was 409.89±35.13 Ncm-2 in comparison to 502.89±55.85 Ncm-2 in the distal portion (p=0.08). Conclusions: The circumferential tensile strength of the ureter was found to be significantly lower than the longitudinal strength. Circumferential tensile strength was also lower with more proximal parts of the ureter. This information may be important for the design of "intelligent" devices and simulators in order to prevent complications.
Risk Factors for Physical Impairment after Acute Lung Injury in a National, Multicenter Study
Wozniak, Amy W.; Hough, Catherine L.; Morris, Peter E.; Dinglas, Victor D.; Jackson, James C.; Mendez-Tellez, Pedro A.; Shanholtz, Carl; Ely, E. Wesley; Colantuoni, Elizabeth
2014-01-01
Rationale: Existing studies of risk factors for physical impairments in acute lung injury (ALI) survivors were potentially limited by single-center design or relatively small sample size. Objectives: To evaluate risk factors for three measures of physical impairments commonly experienced by survivors of ALI in the first year after hospitalization. Methods: A prospective, longitudinal study of 6- and 12-month physical outcomes (muscle strength, 6-minute-walk distance, and Short Form [SF]-36 Physical Function score) for 203 survivors of ALI enrolled from 12 hospitals participating in the ARDS Network randomized trials. Multivariable regression analyses evaluated the independent association of critical illness–related variables and intensive care interventions with impairments in each physical outcome measure, after adjusting for patient demographics, comorbidities, and baseline functional status. Measurements and Main Results: At 6 and 12 months, respectively, mean (± SD) values for strength (presented as proportion of maximum strength score evaluated using manual muscle testing) was 92% (± 8%) and 93% (± 9%), 6-minute-walk distance (as percent-predicted) was 64% (± 22%) and 67% (± 26%), and SF-36 Physical Function score (as percent-predicted) was 61% (± 36%) and 67% (± 37%). After accounting for patient baseline status, there was significant association and statistical interaction of mean daily dose of corticosteroids and intensive care unit length of stay with impairments in physical outcomes. Conclusions: Patients had substantial impairments, from predicted values, for 6-minute-walk distance and SF-36 Physical Function outcome measures. Minimizing corticosteroid dose and implementing existing evidence-based methods to reduce duration of intensive care unit stay and associated patient immobilization may be important interventions for improving ALI survivors’ physical outcomes. PMID:24716641
NASA Astrophysics Data System (ADS)
Srirengan, Kanthikannan
The overall objective of this research was to develop the finite element code required to efficiently predict the strength of plain weave composite structures. Towards which, three-dimensional conventional progressive damage analysis was implemented to predict the strength of plain weave composites subjected to periodic boundary conditions. Also, modal technique for three-dimensional global/local stress analysis was developed to predict the failure initiation in plain weave composite structures. The progressive damage analysis was used to study the effect of quadrature order, mesh refinement and degradation models on the predicted damage and strength of plain weave composites subjected to uniaxial tension in the warp tow direction. A 1/32sp{nd} part of the representative volume element of a symmetrically stacked configuration was analyzed. The tow geometry was assumed to be sinusoidal. Graphite/Epoxy system was used. Maximum stress criteria and combined stress criteria were used to predict failure in the tows and maximum principal stress criterion was used to predict failure in the matrix. Degradation models based on logical reasoning, micromechanics idealization and experimental comparisons were used to calculate the effective material properties with of damage. Modified Newton-Raphson method was used to determine the incremental solution for each applied strain level. Using a refined mesh and the discount method based on experimental comparisons, the progressive damage and the strength of plain weave composites of waviness ratios 1/3 and 1/6 subjected to uniaxial tension in the warp direction have been characterized. Plain weave composites exhibit a brittle response in uniaxial tension. The strength decreases significantly with the increase in waviness ratio. Damage initiation and collapse were caused dominantly due to intra-tow cracking and inter-tow debonding respectively. The predicted strength of plain weave composites of racetrack geometry and waviness ratio 1/25.7 was compared with analytical predictions and experimental findings and was found to match well. To evaluate the performance of the modal technique, failure initiation in a short woven composite cantilevered plate subjected to end moment and transverse end load was predicted. The global/local predictions were found to reasonably match well with the conventional finite element predictions.
Ekren, Orhun; Ozkomur, Ahmet; Ucar, Yurdanur
2018-03-01
Direct metal laser sintering (DMLS) and direct metal laser melting (DMLM) have become popular for fabricating the metal frameworks of metal-ceramic restorations. How the type of layered manufacturing device, layer thickness, and alloy powder may affect the bond strength of ceramic to metal substructure is unclear. The purpose of this in vitro study was to evaluate the bond strength of dental porcelain to metal frameworks fabricated using different layered manufacturing techniques (DMLS and DMLM), Co-Cr alloy powders, and layer thicknesses and to evaluate whether a correlation exists between the bond strength and the number of ceramic remnants on the metal surface. A total of 75 bar-shaped metal specimens (n=15) were fabricated using either DMLS or DMLM. The powder alloys used were Keramit NP-S and EOS-Cobalt-Chrome SP-2 with layer thicknesses of 20 μm and 30 μm. After ceramic application, the metal-ceramic bond strength was evaluated with a 3-point-bend test. Three-way ANOVA followed by the Tukey honest significance difference test were used for statistical analysis (α=.05). De-bonding surface microstructure was observed with scanning electron microscopy. Energy dispersive spectroscopy analysis was conducted to evaluate the correlation between ceramic remnants on the metal surface and bond strength values. The mean bond strength value of DMLS was significantly higher than that of DMLM. While no statistically significant difference was found between layer thicknesses, alloy powders closely affected bond strength. Statistical comparisons revealed that the highest bond strength could be achieved with DMLS-Cobalt-Chrome SP2-20μm, and the lowest bond strength was observed in DMLS-Keramit NP-S-20μm (P≤.05). No correlation was found between porcelain remnants on the metal surface and bond strength values. The layered manufacturing device and the alloy powders evaluated in the current study closely affected the bond strength of dental porcelain to a metal framework. However, layer thickness did not affect the bond strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
In Vitro Evaluation of Shear Bond Strength of Nanocomposites to Dentin
Vellanki, Vinay Kumar; Shetty, Vikram K; Kushwah, Sudhanshu; Goyal, Geeta; Chandra, S.M. Sharath
2015-01-01
Aims: To compare the shear bond strength of nanocomposites to dentin using three different types of adhesive systems; and to test few specimens under Scanning Electron Microscope (SEM) for analysing whether the bond failure is adhesive or cohesive. Materials and Methods: Sixty human premolar teeth were selected and were randomly grouped, with 20 specimens in each group: group 1 - fluoride releasing dentin bonding agent; group 2 - antibacterial containing dentin bonding agent; and group 3 - one step conventional self etch adhesive. Each group was treated with its respective bonding agents, composite resin build up was done, and shear bond strengths were tested using Instron Universal testing machine. Few of the specimens were tested under SEM. Results: The results were statistically analysed using One-way ANOVA and paired t-test. It was observed that group 3 has the highest shear bond strength followed by group 2, and then group 1. Adhesive failures and mixed failures were most frequent types of failures as seen under SEM. Conclusion: Addition of antimicrobial agent decreases the bond strength of dentin bonding agent and addition of fluoride further decreases the bond strength. From SEM results it can be concluded that the zone of failure could not be defined and also that the failure mode was independent of the dentin bonding agent used. PMID:25738077
Mathew, Vinod Babu; Ramachandran, S; Indira, R; Shankar, P
2011-01-01
Background: Dental amalgam is the primary direct posterior restorative material used worldwide, but it have certain shortcomings due to the lack of adhesiveness to the cavity. The introduction of the concept of bonded amalgam helped improve the use of amalgam as a restorative material. Aim: Evaluation of the comparative push-out shear bond strength of four types of conventional glass ionomers used to bond amalgam to tooth in simulated class I situations. Materials and Methods: Four chemical cure glass ionomers are used: GC Fuji I, GC Fuji II, GC Fuji III and GC Fuji VII, and are compared with unbonded amalgam. The push-out bond strength was tested using the Instron Universal Testing Machine at a crosshead speed of 0.5 mm/min. Statistical Analysis: One-way ANOVA and post hoc Bonferroni tests were used to analyze the data. Results: The results showed that the use of glass ionomer to bond amalgam resulted in an increase in the bond strength of amalgam. The Type VII glass ionomer showed the highest bond strength in comparison with the other glass ionomers. Conclusions: Conventional glass ionomer bonds to amalgam and shows a beneficial increase in the bond strength of the restoration in comparison with unbonded amalgam. PMID:22144798
The impact of artificially caries-affected dentin on bond strength of multi-mode adhesives
Follak, Andressa Cargnelutti; Miotti, Leonardo Lamberti; Lenzi, Tathiane Larissa; Rocha, Rachel de Oliveira; Maxnuck Soares, Fabio Zovico
2018-01-01
Aim: The aim of this study is to evaluate the impact of dentin condition on bond strength of multi-mode adhesive systems (MMAS) to sound and artificially induced caries-affected dentin (CAD). Methods: Flat dentin surfaces of 112 bovine incisors were assigned to 16 subgroups (n = 7) according to the substrate condition (sound and CAD– pH-cycling for 14 days); adhesive systems (Scotchbond Universal, All-Bond Universal, Prime and Bond Elect, Adper Single Bond Plus and Clearfil SE Bond) and etching strategy (etch-and-rinse and self-etch). All systems were applied according to the manufacturer's instructions, and resin composite restorations were built. After 24 h of water storage, specimens were sectioned (0.8 mm2) and submitted to the microtensile test. Statistical Analysis: Data (MPa) were analyzed using three-way analysis of variance and Tukey's test (α = 0.05). Results: MMAS presented similar bond strength values, regardless etching strategy in each substrate condition. Bond strength values were lower when MMAS were applied to CAD in the etch-and-rinse strategy. Conclusion: The etching strategy did not influence the bond strength of MMAS to sound or CAD, considering each substrate separately. However, CAD impact negatively on bond strength of MMAS in etch-and rinse mode. PMID:29674813
Cervical isometric strength and range of motion of elite rugby union players: a cohort study
2014-01-01
Background Head and neck injury is relatively common in Rugby Union. Despite this, strength and range-of-motion characteristics of the cervical spine are poorly characterised. The aim of this study was to provide data on the strength and range-of-motion of the cervical spine of professional rugby players to guide clinical rehabilitation. Methods A cohort study was performed evaluating 27 players from a single UK professional rugby club. Cervical isometric strength and range-of-motion were assessed in 3 planes of reference. Anthropometric data was collected and multivariate regression modelling performed with a view to predicting cervical isometric strength. Results Largest forces were generated in extension, with broadly equal isometric side flexion forces at around 90% of extension values. The forwards generated significantly more force than the backline in all parameters bar flexion. The forwards had substantially reduced cervical range-of-motion and larger body mass, with differences observed in height, weight, neck circumference and chest circumference (p < 0.002). Neck circumference was the sole predictor of isometric extension (adjusted R2 = 30.34). Conclusion Rehabilitative training programs aim to restore individuals to pre-injury status. This work provides reference ranges for the strength and range of motion of the cervical spine of current elite level rugby players. PMID:25120916
Isometric Shoulder Strength Reference Values for Physically Active Collegiate Males and Females
Westrick, Richard B.; Duffey, Michele L.; Cameron, Kenneth L.; Gerber, J. Parry; Owens, Brett D.
2013-01-01
Background: It is common clinical practice to assess muscle strength during examination of patients following shoulder injury or surgery. Strength comparisons are often made between the patient’s injured and uninjured shoulders, with the uninjured side used as a reference without regard to upper extremity dominance. Despite the importance of strength measurements, little is known about expected normal baselines of the uninjured shoulder. The purpose of this study was to report normative values for isometric shoulder strength for physically active college-age men and women without history of shoulder injury. Methods: University students—546 males (18.8 ± 1.0 years, 75.3 ± 12.2 kg) and 73 females (18.7 ± 0.9 years, 62.6 ± 7.0 kg)—underwent thorough shoulder evaluations by an orthopaedic surgeon and completed bilateral isometric strength measurements with a handheld dynamometer. Variables measured included internal rotation, external rotation, abduction, supine internal rotation and external rotation at 45°, and lower trapezius in prone flexion. Results: Significant differences were found between the dominant and nondominant shoulder for internal rotation, internal rotation at 45°, abduction, and prone flexion in males and in internal rotation at 45° and prone flexion for females (P ≤ 0.01). PMID:24381696
Ghavamnasiri, Marjaneh; Eslami, Samaneh; Ameri, Hamide; Chasteen, Joseph E.; Majidinia, Sara; Moghadam, Fatemeh Velayaty
2015-01-01
Objectives: To evaluate the effect of amalgam corrosion products in non-discolored dentin on the bond strength of replaced composite resin. Materials and Methods: One hundred and sixty-one Class I cavities were prepared on extracted premolars and divided into seven groups. Group 1: Light-cured composite; Groups 2, 3, and 4: Amalgam stored in 37°C normal saline for respectively 1, 3, and 6 months and then replaced with composite leaving the cavity walls intact. Groups 5, 6, and 7: Identical to Groups 2, 3, and 4, except the cavity walls were extended 0.5 mm after amalgam removal. Eighteen specimens from each group were selected for shear bond strength testing, while on remaining five samples, elemental microanalysis was conducted. Data were analyzed using Mann-Whitney and Freidman (α = 0.05). Results: There was a significant difference between Groups 1 and 4 and also between Group 1 and Groups 5, 6, and 7. However, Groups 1, 2, and 3 showed no significant difference regarding bond strength. Bond strengths of Group 4 was significantly less than Groups 2 and 3. However, Groups 5, 6, and 7 showed similar bond strength. There was no difference among all groups in terms of metal elements at any storage times. PMID:25657522
Yoo, H M; Oh, T S; Pereira, P N R
2006-01-01
This study evaluated the effect of saliva contamination and decontamination methods on the dentin bond strength of one-step self-etching adhesive systems. Three commercially available "all-in-one" adhesives (One Up Bond F, Xeno III and Adper Prompt) and one resin composite (Filtek Z-250) were used. Third molars stored in distilled water with 0.5% thymol at 4 degrees C were ground with #600 SiC paper under running water to produce a standardized smear layer. The specimens were randomly divided into groups according to contamination methods: no contamination, which was the control (C); contamination of the adhesive surface with fresh saliva before light curing (A) and contamination of the adhesive surface with fresh saliva after light curing (B). Each contamination group was further subdivided into three subgroups according to the decontamination method: A1-Saliva was removed by a gentle air blast and the adhesive was light-cured; A2-Saliva was rinsed for 10 seconds, gently air-dried and the was adhesive light-cured; A3-Saliva was rinsed and dried as in A2, then the adhesive was re-applied to the dentin surface and light-cured; B1-Saliva was removed with a gentle air blast; B2-Saliva was rinsed and dried; B3-Saliva was rinsed, dried and the adhesive was re-applied and light cured. Tygon tubes filled with resin composite were placed on each surface and light cured. All specimens were stored in distilled water at 37 degrees C for 24 hours. Microshear bond strength was measured using a universal testing machine (EZ test), and data were analyzed by one-way ANOVA followed by the Duncan test to make comparisons among the groups (p<0.05). After debonding, five specimens were selected and examined in a scanning electron microscope to evaluate the modes of fracture. The A2 subgroup resulted in the lowest bond strength. For One Up Bond F and Adper Prompt, there was no significant difference between subgroup A1 and the control, and subgroup A3 and the control (p>0.05). Bond strengths of all B groups were significantly lower compared to the controls (p<0.05). For Xeno III, A1 subgroup showed the greatest decrease in bond strength as compared to the control (p<0.05). On the other hand, it showed more resistance to salivary contamination after adhesive curing. There was no statistically significant difference among the control groups (p>0.05).
Uncertainty during breast diagnostic evaluation: state of the science.
Montgomery, Mariann
2010-01-01
To present the state of the science on uncertainty in relationship to the experiences of women undergoing diagnostic evaluation for suspected breast cancer. Published articles from Medline, CINAHL, PubMED, and PsycINFO from 1983-2008 using the following key words: breast biopsy, mammography, uncertainty, reframing, inner strength, and disruption. Fifty research studies were examined with all reporting the presence of anxiety persisting throughout the diagnostic evaluation until certitude is achieved through the establishment of a definitive diagnosis. Indirect determinants of uncertainty for women undergoing breast diagnostic evaluation include measures of anxiety, depression, social support, emotional responses, defense mechanisms, and the psychological impact of events. Understanding and influencing the uncertainty experience have been suggested to be key in relieving psychosocial distress and positively influencing future screening behaviors. Several studies examine correlational relationships among anxiety, selection of coping methods, and demographic factors that influence uncertainty. A gap exists in the literature with regard to the relationship of inner strength and uncertainty. Nurses can be invaluable in assisting women in coping with the uncertainty experience by providing positive communication and support. Nursing interventions should be designed and tested for their effects on uncertainty experienced by women undergoing a breast diagnostic evaluation.
Singh, Shipra; Nagpal, Rajni; Tyagi, Shashi Prabha; Manuja, Naveen
2015-01-01
Objective. This study evaluated the effect of ethylenediaminetetraacetic acid (EDTA) conditioning and carbodiimide (EDC) pretreatment on the shear bond strength of two all-in-one self-etch adhesives to dentin. Methods. Flat coronal dentin surfaces were prepared on one hundred and sixty extracted human molars. Teeth were randomly divided into eight groups according to two different self-etch adhesives used [G-Bond and OptiBond-All-In-One] and four different surface pretreatments: (a) adhesive applied following manufacturer's instructions; (b) dentin conditioning with 24% EDTA gel prior to application of adhesive; (c) EDC pretreatment followed by application of adhesive; (d) application of EDC on EDTA conditioned dentin surface followed by application of adhesive. Composite restorations were placed in all the samples. Ten samples from each group were subjected to immediate and delayed (6-month storage in artificial saliva) shear bond strength evaluation. Data collected was subjected to statistical analysis using three-way ANOVA and post hoc Tukey's test at a significance level of p < 0.05. Results and Conclusion. EDTA preconditioning as well as EDC pretreatment alone had no significant effect on the immediate and delayed bond strengths of either of the adhesives. However, EDC pretreatment on EDTA conditioned dentin surface resulted in preservation of resin-dentin bond strength of both adhesives with no significant fall over six months. PMID:26557850
NASA Astrophysics Data System (ADS)
Khalifa, H. E.; Deck, C. P.; Gutierrez, O.; Jacobsen, G. M.; Back, C. A.
2015-02-01
The use of silicon carbide (SiC) composites as structural materials in nuclear applications necessitates the development of a viable joining method. One critical application for nuclear-grade joining is the sealing of fuel within a cylindrical cladding. This paper demonstrates cylindrical joint feasibility using a low activation nuclear-grade joint material comprised entirely of β-SiC. While many papers have considered joining material, this paper takes into consideration the joint geometry and component form factor, as well as the material performance. Work focused specifically on characterizing the strength and permeability performance of joints between cylindrical SiC-SiC composites and monolithic SiC endplugs. The effects of environment and neutron irradiation were not evaluated in this study. Joint test specimens of different geometries were evaluated in their as-fabricated state, as well as after being subjected to thermal cycling and partial mechanical loading. A butted scarf geometry supplied the best combination of high strength and low permeability. A leak rate performance of 2 × 10-9 mbar l s-1 was maintained after thermal cycling and partial mechanical loading and sustained applied force of 3.4 kN, or an apparent strength of 77 MPa. This work shows that a cylindrical SiC-SiC composite tube sealed with a butted scarf endplug provides out-of-pile strength and permeability performance that meets light water reactor design requirements.
The Effect of Remin Pro and MI Paste Plus on Bleached Enamel Surface Roughness
Ahmad Akhoundi, Mohammad Sadegh; Aghajani, Farzaneh; Chalipa, Javad; Sadrhaghighi, Amir Hooman
2014-01-01
Objective Increased number of adult patients requesting orthodontic treatment result in bonding bracket to ceramic restorations more than before. The aim of this study was to evaluate and compare the shear bond strength of orthodontic brackets bonded to two types of ceramic bases with conventional orthodontic bonding resin and a new nano-filled composite resin. Materials and Methods: Twenty four feldespathic porcelain and 24 lithium disilicate ceramic disks were fabricated. All of the samples were conditioned by sandblasting, hydrofluoric acid and silane. Maxillary incisor metal brackets were bonded to half of the disks in each group by conventional orthodontic bonding resin and the other half bonded with a nano-filled composite. The samples then were thermocycled for 2000 cycle between 5–55° C. Shear bond strength was measured and the mode of failure was examined. Randomly selected samples were also evaluated by SEM. Results: The lowest bond strength value was found infeldespathic ceramic bonded by nano-filled composite (p<0.05). There was not any statistically significant difference between other groups regarding bond strength. The mode of failure in the all groups except group 1 was cohesive and porcelain damages were detected. Conclusion: Since less damages to feldspathic porcelain was observed when the nano-filled composite was used to bond brackets, the use of nano-filled composite resins can be suggested for bonding brackets to feldspathic porcelain restorations. PMID:24910698
Parisay, Iman; Khazaei, Yegane
2018-01-01
Background: Stainless steel crown (SSC) is the most reliable restoration for primary teeth with extensive caries. Retention is of great importance for a successful restoration and is provided by various factors such as luting cements. The aim of this study was to evaluate the retentive strength of SSC cemented with four different luting cements. Materials and Methods: In this in vitro study, A total of 55 extracted primary first molars were selected. Following crown selection and cementation (one with no cement and four groups cemented with resin, glass ionomer, zinc phosphate, and polycarboxylate), all the specimens were incubated and thermocycled in 5°C–55°C. Retentive properties of SSCs were tested with a mechanical test machine. First dislodgement of each specimen and full crown removal were recorded. One-way ANOVA test followed by least significant difference test and Kruskal–Wallis test was used for retentive strength comparison at the level of significance of P < 0.05. Results: The results of the study showed that the specimens cemented with zinc phosphate exhibited higher retentive strength as compared to glass ionomer and polycarboxylate (P < 0.001 and P = 0.023, respectively). Conclusion: Zinc phosphate cement showed the most promising results; thus, it can be preferably used for cementation of the teeth with no grossly broken down crowns. PMID:29922339
Lip, Ryan W T; Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Guo, X
2015-03-01
[Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation.
Lip, Ryan W.T.; Fong, Shirley S.M.; Ng, Shamay S.M.; Liu, Karen P.Y.; Guo, X.
2015-01-01
[Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation. PMID:25931704
Guidelines for Design and Analysis of Large, Brittle Spacecraft Components
NASA Technical Reports Server (NTRS)
Robinson, E. Y.
1993-01-01
There were two related parts to this work. The first, conducted at The Aerospace Corporation was to develop and define methods for integrating the statistical theory of brittle strength with conventional finite element stress analysis, and to carry out a limited laboratory test program to illustrate the methods. The second part, separately funded at Aerojet Electronic Systems Division, was to create the finite element postprocessing program for integrating the statistical strength analysis with the structural analysis. The second part was monitored by Capt. Jeff McCann of USAF/SMC, as Special Study No.11, which authorized Aerojet to support Aerospace on this work requested by NASA. This second part is documented in Appendix A. The activity at Aerojet was guided by the Aerospace methods developed in the first part of this work. This joint work of Aerospace and Aerojet stemmed from prior related work for the Defense Support Program (DSP) Program Office, to qualify the DSP sensor main mirror and corrector lens for flight as part of a shuttle payload. These large brittle components of the DSP sensor are provided by Aerojet. This document defines rational methods for addressing the structural integrity and safety of large, brittle, payload components, which have low and variable tensile strength and can suddenly break or shatter. The methods are applicable to the evaluation and validation of such components, which, because of size and configuration restrictions, cannot be validated by direct proof test.
Asakawa, Yuya; Takahashi, Hidekazu; Kobayashi, Masahiro; Iwasaki, Naohiko
2013-10-01
The aim of this study was to clarify the effect of the components and surface treatments of fiber-reinforced composite (FRC) posts on the durable bonding to core build-up resin evaluated using the pull-out and microtensile tests. Four types of experimental FRC posts, combinations of two types of matrix resins (polymethyl methacrylate and urethane dimethacrylate) and two types of fiberglass (E-glass and zirconia-containing glass) were examined. The FRC posts were subjected to one of three surface treatments (cleaned with ethanol, dichloromethane, or sandblasting). The bond strength between the FRC posts and core build-up resin were measured using the pull-out and microtensile tests before and after thermal cycling. The bond strengths obtained by each test before and after thermal cycling were statistically analyzed by three-way ANOVA and Tukey's multiple comparisons test (p<0.05). The bond strengths except for UDMA by the pull-out test decreased after thermal cycling. Regardless the test method and thermal cycling, matrix resins, the surface treatment and their interaction were statistically significant, but fiberglass did not. Dichloromethane treatment was effective for the PMMA-based FRC posts by the pull-out test, but not by the microtensile test. Sandblasting was effective for both PMMA- and UDMA-based FRC posts, regardless of the test method. The bond strengths were influenced by the matrix resin of the FRC post and the surface treatment. The bond strengths of the pull-out test showed a similar tendency of those of the microtensile test, but the value obtained by these test were different. Copyright © 2013 Elsevier Ltd. All rights reserved.
Marta, Carlos C; Marinho, Daniel A; Barbosa, Tiago M; Carneiro, André L; Izquierdo, Mikel; Marques, Mário C
2013-12-01
The purpose of this study was to analyze the influence of body fat and somatotype on explosive strength and aerobic capacity trainability in the prepubertal growth spurt, marked by rapid changes in body size, shape, and composition, all of which are sexually dimorphic. One hundred twenty-five healthy children (58 boys, 67 girls), aged 10-11 years (10.8 ± 0.4 years), who were self-assessed in Tanner stages 1-2, were randomly assigned into 2 experimental groups to train twice a week for 8 weeks: strength training group (19 boys, 22 girls), endurance training group (21 boys, 24 girls), and a control group (18 boys, 21 girls). Evaluation of body fat was carried out using the method described by Slaughter. Somatotype was computed according to the Heath-Carter method. Increased endomorphy reduced the likelihood of vertical jump height improvement (odds ratio [OR], 0.10; 95% confidence interval [CI], 0.01-0.85), increased mesomorphy (OR, 6.15; 95% CI, 1.52-24.88) and ectomorphy (OR, 6.52; 95% CI, 1.71-24.91) increased the likelihood of sprint performance, and increased ectomorphy (OR, 3.84; 95% CI, 1.20-12.27) increased the likelihood of aerobic fitness gains. Sex did not affect the training-induced changes in strength or aerobic fitness. These data suggest that somatotype has an effect on explosive strength and aerobic capacity trainability, which should not be disregarded. The effect of adiposity on explosive strength, musculoskeletal magnitude on running speed, and relative linearity on running speed and aerobic capacity seem to be crucial factors related to training-induced gains in prepubescent boys and girls.
Zorba, Yahya Orcun; Ilday, Nurcan Ozakar; Bayındır, Yusuf Ziya; Demirbuga, Sezer
2013-01-01
Objective: The aim of this study was to test the null hypothesis that different surface conditioning (etch and rinse and self-etch) and curing techniques (light cure/dual cure) had no effect on the shear bond strength of direct and indirect composite inlays. Materials and Methods: A total of 112 extracted human molar teeth were horizontally sectioned and randomly divided into two groups according to restoration technique (direct and indirect restorations). Each group was further subdivided into seven subgroups (n = 8) according to bonding agent (etch and rinse adhesives Scotchbond multi-purpose plus, All-Bond 3, Adper Single Bond and Prime Bond NT; and self-etch adhesives Clearfil Liner Bond, Futurabond DC and G bond). Indirect composites were cemented to dentin surfaces using dual-curing luting cement. Shear bond strength of specimens was tested using a Universal Testing Machine. Two samples from each subgroup were evaluated under Scanning electron microscopy to see the failing modes. Data was analyzed using independent sample t-tests and Tukey's tests. Results: Surface conditioning and curing of bonding agents were all found to have significant effects on shear bond strength (P < 0.05) of both direct and indirect composite inlays. With direct restoration, etch and rinse systems and dual-cured bonding agents yielded higher bond strengths than indirect restoration, self-etch systems and light-cured bonding agents. Conclusions: The results of the present study indicated that direct restoration to be a more reliable method than indirect restoration. Although etch and rinse bonding systems showed higher shear bond strength to dentin than self-etch systems, both systems can be safely used for the adhesion of direct as well as indirect restorations. PMID:24932118
Type-2 fuzzy set extension of DEMATEL method combined with perceptual computing for decision making
NASA Astrophysics Data System (ADS)
Hosseini, Mitra Bokaei; Tarokh, Mohammad Jafar
2013-05-01
Most decision making methods used to evaluate a system or demonstrate the weak and strength points are based on fuzzy sets and evaluate the criteria with words that are modeled with fuzzy sets. The ambiguity and vagueness of the words and different perceptions of a word are not considered in these methods. For this reason, the decision making methods that consider the perceptions of decision makers are desirable. Perceptual computing is a subjective judgment method that considers that words mean different things to different people. This method models words with interval type-2 fuzzy sets that consider the uncertainty of the words. Also, there are interrelations and dependency between the decision making criteria in the real world; therefore, using decision making methods that cannot consider these relations is not feasible in some situations. The Decision-Making Trail and Evaluation Laboratory (DEMATEL) method considers the interrelations between decision making criteria. The current study used the combination of DEMATEL and perceptual computing in order to improve the decision making methods. For this reason, the fuzzy DEMATEL method was extended into type-2 fuzzy sets in order to obtain the weights of dependent criteria based on the words. The application of the proposed method is presented for knowledge management evaluation criteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaguchi, Nobuyoshi; Nakao, Masato; Murakami, Masahide
2008-07-08
For seismic design, ductility-related force modification factors are named R factor in Uniform Building Code of U.S, q factor in Euro Code 8 and Ds (inverse of R) factor in Japanese Building Code. These ductility-related force modification factors for each type of shear elements are appeared in those codes. Some constructions use various types of shear walls that have different ductility, especially for their retrofit or re-strengthening. In these cases, engineers puzzle the decision of force modification factors of the constructions. Solving this problem, new method to calculate lateral strengths of stories for simple shear wall systems is proposed andmore » named 'Stiffness--Potential Energy Addition Method' in this paper. This method uses two design lateral strengths for each type of shear walls in damage limit state and safety limit state. Two lateral strengths of stories in both limit states are calculated from these two design lateral strengths for each type of shear walls in both limit states. Calculated strengths have the same quality as values obtained by strength addition method using many steps of load-deformation data of shear walls. The new method to calculate ductility factors is also proposed in this paper. This method is based on the new method to calculate lateral strengths of stories. This method can solve the problem to obtain ductility factors of stories with shear walls of different ductility.« less
Shear Strength of Remoulding Clay Samples Using Different Methods of Moulding
NASA Astrophysics Data System (ADS)
Norhaliza, W.; Ismail, B.; Azhar, A. T. S.; Nurul, N. J.
2016-07-01
Shear strength for clay soil was required to determine the soil stability. Clay was known as a soil with complex natural formations and very difficult to obtain undisturbed samples at the site. The aim of this paper was to determine the unconfined shear strength of remoulded clay on different methods in moulding samples which were proctor compaction, hand operated soil compacter and miniature mould methods. All the samples were remoulded with the same optimum moisture content (OMC) and density that were 18% and 1880 kg/m3 respectively. The unconfined shear strength results of remoulding clay soils for proctor compaction method was 289.56kPa with the strain 4.8%, hand operated method was 261.66kPa with the strain 4.4% and miniature mould method was 247.52kPa with the strain 3.9%. Based on the proctor compaction method, the reduction percentage of unconfined shear strength of remoulded clay soil of hand operated method was 9.66%, and for miniature mould method was 14.52%. Thus, because there was no significant difference of reduction percentage of unconfined shear strength between three different methods, so it can be concluded that remoulding clay by hand operated method and miniature mould method were accepted and suggested to perform remoulding clay samples by other future researcher. However for comparison, the hand operated method was more suitable to form remoulded clay sample in term of easiness, saving time and less energy for unconfined shear strength determination purposes.
[Evaluation of the capacity of work using upper limbs after radical latero-cervical surgery].
Capodaglio, P; Strada, M R; Grilli, C; Lodola, E; Panigazzi, M; Bernardo, G; Bazzini, G
1998-01-01
Evaluation of arm work capacity after radical neck surgery. The aim of this paper is to describe an approach for the assessment of work capacity in patients who underwent radical neck surgery, including those treated with radiation therapy. Nine male patients, who underwent radical neck surgery 2 months before being referred to our Unit, participated in the study. In addition to manual muscle strength test, we performed the following functional evaluations: 0-100 Constant scale for shoulder function; maximal shoulder strength in adduction/abduction and intrarotation/extrarotation; instrumental. We measured maximal isokinetic strength (10 repetitions) with a computerized dynamometer (Lido WorkSET) set at 100 degrees/sec. During the rehabilitation phase, the patients' mechanical parameters, the perception of effort, pain or discomfort, and the range of movement were monitored while performing daily/occupational task individually chosen on the simulator (Lido WorkSET) under isotonic conditions. On this basis, patients were encouraged to return to levels of daily physical activities compatible with the individual tolerable work load. The second evaluation at 2 month confirmed that the integrated rehabilitation protocol successfully increased patients' capacities and "trust" in their physical capacity. According to the literature, the use of isokinetic and isotonic exercise programs appears to decrease shoulder rehabilitation time. In our experience an excellent compliance has been noted. One of the advantages of the method proposed is to provide quantitative reports of the functional capacity and therefore to facilitate return-to-work of patients who underwent radical neck surgery.