Sample records for strength test stand

  1. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain: What are the Clinical Implications of Pain During Testing?

    PubMed

    Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian

    2016-05-01

    To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.

  2. ROBERT BOBO AND MIKE NICHOLS AT TEST STAND 4693

    NASA Image and Video Library

    2016-12-14

    ROBERT BOBO, LEFT, AND MIKE NICHOLS TALK BENEATH THE 221-FOOT-TALL TEST STAND 4693, THE LARGEST OF TWO NEW SPACE LAUNCH SYSTEM TEST STANDS AT MSFC. BOBO MANAGES SLS STRUCTURAL STRENGTH TESTING, AND NICHOLS IS LEAD TEST ENGINEER FOR THE SLS LIQUID HYDROGEN TANK.

  3. Integrative Examination of Motor Abilities in Dialysis Patients and Selection of Tests for a Standardized Physical Function Assessment.

    PubMed

    Bučar Pajek, Maja; Leskošek, Bojan; Vivoda, Tjaša; Svilan, Katarina; Čuk, Ivan; Pajek, Jernej

    2016-06-01

    To reduce the need for a large number of executed physical function tests we examined inter-relations and determined predictive power for daily physical activity of the following tests: 6-min walk, 10 repetition sit-to-stand, time up-and-go, Storke balance, handgrip strength, upper limb tapping and sitting forward bend tests. In 90 dialysis and 140 healthy control subjects we found high correlations between all tests, especially those engaging lower extremities. Sit-to-stand, forward bend and handgrip strength were selected for the test battery and composite motor performance score. Sit-to-stand test was superior in terms of sensitivity to uremia effects and association with daily physical function in adjusted analyses. There was no incremental value in calculating the composite performance score. We propose to standardize the physical function assessment of dialysis patients for cross-sectional and longitudinal observations with three simple, cheap, well-accessible and easily performed test tools: sit-to-stand test, handgrip strength and Human Activity Profile questionnaire. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  4. Effect of Lower Limb Strength on Falls and Balance of the Elderly

    PubMed Central

    Cho, Kang Hee; Bok, Soo Kyung; Hwang, Seon Lyul

    2012-01-01

    Objective To assess the effect of lower limb strength on falls and balance in community-dwelling elderly persons by a health status questionnaire, evaluation of lower limb strength and balance. Method A total of 86 subjects (age 69.8±5.3) were categorized into one of two groups, "Fallers" and "Non-fallers". Thirty one participants who had reported the experience of having fallen unexpectedly at least once in the past year were assigned into the group "Fallers", and the remaining 55 subjects having no fall history in the past year, "Non-fallers". A self-assessment questionnaire was taken. Lower limb strength was measured by a "Chair stand test". Balance was measured by the stability index of the fall risk test protocol of Balance System SD® (Biodex, New York, USA). The differences between the two groups were compared and the correlation between lower limb strength and balance were analyzed. Results The questionnaire demonstrated no significant differences between two groups. The "Chair stand test" showed a significantly less for the "Fallers" (p<0.05). The stability index was significantly greater in the "Fallers" group (p<0.05). There was a moderate negative correlation between the "Chair stand test" and the "Stability index" (R=-0.576, p<0.01). Conclusion This study suggests that the "Chair stand test" is a useful screening process for lower limb strength which correlates to risk for falls and balance in the elderly. PMID:22837975

  5. Relationship between strength, power and balance performance in seniors.

    PubMed

    Muehlbauer, Thomas; Besemer, Carmen; Wehrle, Anja; Gollhofer, Albert; Granacher, Urs

    2012-01-01

    Deficits in strength, power and balance represent important intrinsic risk factors for falls in seniors. The purpose of this study was to investigate the relationship between variables of lower extremity muscle strength/power and balance, assessed under various task conditions. Twenty-four healthy and physically active older adults (mean age: 70 ± 5 years) were tested for their isometric strength (i.e. maximal isometric force of the leg extensors) and muscle power (i.e. countermovement jump height and power) as well as for their steady-state (i.e. unperturbed standing, 10-meter walk), proactive (i.e. Timed Up & Go test, Functional Reach Test) and reactive (i.e. perturbed standing) balance. Balance tests were conducted under single (i.e. standing or walking alone) and dual task conditions (i.e. standing or walking plus cognitive and motor interference task). Significant positive correlations were found between measures of isometric strength and muscle power of the lower extremities (r values ranged between 0.608 and 0.720, p < 0.01). Hardly any significant associations were found between variables of strength, power and balance (i.e. no significant association in 20 out of 21 cases). Additionally, no significant correlations were found between measures of steady-state, proactive and reactive balance or balance tests performed under single and dual task conditions (all p > 0.05). The predominately nonsignificant correlations between different types of balance imply that balance performance is task specific in healthy and physically active seniors. Further, strength, power and balance as well as balance under single and dual task conditions seem to be independent of each other and may have to be tested and trained complementarily. Copyright © 2012 S. Karger AG, Basel.

  6. Associations of knee extensor strength and standing balance with physical function in knee osteoarthritis.

    PubMed

    Pua, Yong-Hao; Liang, Zhiqi; Ong, Peck-Hoon; Bryant, Adam L; Lo, Ngai-Nung; Clark, Ross A

    2011-12-01

    Knee extensor strength is an important correlate of physical function in patients with knee osteoarthritis; however, it remains unclear whether standing balance is also a correlate. The purpose of this study was to evaluate the cross-sectional associations of knee extensor strength, standing balance, and their interaction with physical function. One hundred four older adults with end-stage knee osteoarthritis awaiting a total knee replacement (mean ± SD age 67 ± 8 years) participated. Isometric knee extensor strength was measured using an isokinetic dynamometer. Standing balance performance was measured by the center of pressure displacement during quiet standing on a balance board. Physical function was measured by the self-report Short Form 36 (SF-36) questionnaire and by the 10-meter fast-pace gait speed test. After adjustment for demographic and knee pain variables, we detected significant knee strength by standing balance interaction terms for both SF-36 physical function and fast-pace gait speed. Interrogation of the interaction revealed that standing balance in the anteroposterior plane was positively related to physical function among patients with lower knee extensor strength. Conversely, among patients with higher knee extensor strength, the standing balance-physical function associations were, or tended to be, negative. These findings suggest that although standing balance was related to physical function in patients with knee osteoarthritis, this relationship was complex and dependent on knee extensor strength level. These results are of importance in developing intervention strategies and refining theoretical models, but they call for further study. Copyright © 2011 by the American College of Rheumatology.

  7. Measuring Quadriceps strength in adults with severe or moderate intellectual and visual disabilities: Feasibility and reliability.

    PubMed

    Dijkhuizen, Annemarie; Douma, Rob K; Krijnen, Wim P; van der Schans, Cees P; Waninge, Aly

    2018-05-30

    A feasible and reliable instrument to measure strength in persons with severe intellectual and visual disabilities (SIVD) is lacking. The aim of our study was to determine feasibility, learning period and reliability of three strength tests. Twenty-nine participants with SIVD performed the Minimum Sit-to-Stand Height test (MSST), the Leg Extension test (LE) and the 30 seconds Chair-Stand test (30sCS), once per week for 5 weeks. Feasibility was determined by the percentage of successful measurements; learning effect by using paired t test between two consecutive measurements; test-retest reliability by intraclass correlation coefficient and Limits of Agreement and, correlations by Pearson correlations. A sufficient feasibility and learning period of the tests was shown. The methods had sufficient test-retest reliability and moderate-to-sufficient correlations. The MSST, the LE, and the 30sCS are feasible tests for measuring muscle strength in persons with SIVD, having sufficient test re-test reliability. © 2018 John Wiley & Sons Ltd.

  8. Contributions to lateral balance control in ambulatory older adults.

    PubMed

    Sparto, Patrick J; Newman, A B; Simonsick, E M; Caserotti, P; Strotmeyer, E S; Kritchevsky, S B; Yaffe, K; Rosano, C

    2018-06-01

    In older adults, impaired control of standing balance in the lateral direction is associated with the increased risk of falling. Assessing the factors that contribute to impaired standing balance control may identify areas to address to reduce falls risk. To investigate the contributions of physiological factors to standing lateral balance control. Two hundred twenty-two participants from the Pittsburgh site of the Health, Aging and Body Composition Study had lateral balance control assessed using a clinical sensory integration balance test (standing on level and foam surface with eyes open and closed) and a lateral center of pressure tracking test using visual feedback. The center of pressure was recorded from a force platform. Multiple linear regression models examined contributors of lateral control of balance performance, including concurrently measured tests of lower extremity sensation, knee extensor strength, executive function, and clinical balance tests. Models were adjusted for age, body mass index, and sex. Larger lateral sway during the sensory integration test performed on foam was associated with longer repeated chair stands time. During the lateral center of pressure tracking task, the error in tracking increased at higher frequencies; greater error was associated with worse executive function. The relationship between sway performance and physical and cognitive function differed between women and men. Contributors to control of lateral balance were task-dependent. Lateral standing performance on an unstable surface may be more dependent upon general lower extremity strength, whereas visual tracking performance may be more dependent upon cognitive factors. Lateral balance control in ambulatory older adults is associated with deficits in strength and executive function.

  9. Impact of pain reported during isometric quadriceps muscle strength testing in people with knee pain: data from the osteoarthritis initiative.

    PubMed

    Riddle, Daniel L; Stratford, Paul W

    2011-10-01

    Muscle force testing is one of the more common categories of diagnostic tests used in clinical practice. Clinicians have little evidence to guide interpretations of muscle force tests when pain is elicited during testing. The purpose of this study was to examine the construct validity of isometric quadriceps muscle strength tests by determining whether the relationship between maximal isometric quadriceps muscle strength and functional status was influenced by pain during isometric testing. A cross-sectional design was used. Data from the Osteoarthritis Initiative were used to identify 1,344 people with unilateral knee pain and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale scores of 1 or higher on the involved side. Measurements of maximal isometric quadriceps strength and ratings of pain during isometric testing were collected. Outcome variables were WOMAC physical function subscale, 20-m walk test, 400-m walk test, and a repeated chair stand test. Multiple regression models were used to determine whether pain during testing modified or confounded the relationship between strength and functional status. Pearson r correlations among the isometric quadriceps strength measures and the 4 outcome measures ranged from -.36 (95% confidence interval=-.41, -.31) for repeated chair stands to .36 (95% confidence interval=.31, .41) for the 20-m walk test. In the final analyses, neither effect modification nor confounding was found for the repeated chair stand test, the 20-m walk test, the 400-m walk test, or the WOMAC physical function subscale. Moderate or severe pain during testing was weakly associated with reduced strength, but mild pain was not. The disease spectrum was skewed toward mild or moderate symptoms, and the pain measurement scale used during muscle force testing was not ideal. Given that the spectrum of the sample was skewed toward mild or moderate symptoms and disease, the data suggest that isometric quadriceps muscle strength tests maintain their relationship with self-report or performance-based disability measures even when pain is elicited during testing.

  10. Impact of Pain Reported During Isometric Quadriceps Muscle Strength Testing in People With Knee Pain: Data From the Osteoarthritis Initiative

    PubMed Central

    Stratford, Paul W.

    2011-01-01

    Background Muscle force testing is one of the more common categories of diagnostic tests used in clinical practice. Clinicians have little evidence to guide interpretations of muscle force tests when pain is elicited during testing. Objective The purpose of this study was to examine the construct validity of isometric quadriceps muscle strength tests by determining whether the relationship between maximal isometric quadriceps muscle strength and functional status was influenced by pain during isometric testing. Design A cross-sectional design was used. Methods Data from the Osteoarthritis Initiative were used to identify 1,344 people with unilateral knee pain and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale scores of 1 or higher on the involved side. Measurements of maximal isometric quadriceps strength and ratings of pain during isometric testing were collected. Outcome variables were WOMAC physical function subscale, 20-m walk test, 400-m walk test, and a repeated chair stand test. Multiple regression models were used to determine whether pain during testing modified or confounded the relationship between strength and functional status. Results Pearson r correlations among the isometric quadriceps strength measures and the 4 outcome measures ranged from −.36 (95% confidence interval=−.41, −.31) for repeated chair stands to .36 (95% confidence interval=.31, .41) for the 20-m walk test. In the final analyses, neither effect modification nor confounding was found for the repeated chair stand test, the 20-m walk test, the 400-m walk test, or the WOMAC physical function subscale. Moderate or severe pain during testing was weakly associated with reduced strength, but mild pain was not. Limitations The disease spectrum was skewed toward mild or moderate symptoms, and the pain measurement scale used during muscle force testing was not ideal. Conclusions Given that the spectrum of the sample was skewed toward mild or moderate symptoms and disease, the data suggest that isometric quadriceps muscle strength tests maintain their relationship with self-report or performance-based disability measures even when pain is elicited during testing. PMID:21835892

  11. Effects of core strength training using stable versus unstable surfaces on physical fitness in adolescents: a randomized controlled trial.

    PubMed

    Granacher, Urs; Schellbach, Jörg; Klein, Katja; Prieske, Olaf; Baeyens, Jean-Pierre; Muehlbauer, Thomas

    2014-01-01

    It has been demonstrated that core strength training is an effective means to enhance trunk muscle strength (TMS) and proxies of physical fitness in youth. Of note, cross-sectional studies revealed that the inclusion of unstable elements in core strengthening exercises produced increases in trunk muscle activity and thus provide potential extra training stimuli for performance enhancement. Thus, utilizing unstable surfaces during core strength training may even produce larger performance gains. However, the effects of core strength training using unstable surfaces are unresolved in youth. This randomized controlled study specifically investigated the effects of core strength training performed on stable surfaces (CSTS) compared to unstable surfaces (CSTU) on physical fitness in school-aged children. Twenty-seven (14 girls, 13 boys) healthy subjects (mean age: 14 ± 1 years, age range: 13-15 years) were randomly assigned to a CSTS (n = 13) or a CSTU (n = 14) group. Both training programs lasted 6 weeks (2 sessions/week) and included frontal, dorsal, and lateral core exercises. During CSTU, these exercises were conducted on unstable surfaces (e.g., TOGU© DYNAIR CUSSIONS, THERA-BAND© STABILITY TRAINER). Significant main effects of Time (pre vs. post) were observed for the TMS tests (8-22%, f = 0.47-0.76), the jumping sideways test (4-5%, f = 1.07), and the Y balance test (2-3%, f = 0.46-0.49). Trends towards significance were found for the standing long jump test (1-3%, f = 0.39) and the stand-and-reach test (0-2%, f = 0.39). We could not detect any significant main effects of Group. Significant Time x Group interactions were detected for the stand-and-reach test in favour of the CSTU group (2%, f = 0.54). Core strength training resulted in significant increases in proxies of physical fitness in adolescents. However, CSTU as compared to CSTS had only limited additional effects (i.e., stand-and-reach test). Consequently, if the goal of training is to enhance physical fitness, then CSTU has limited advantages over CSTS. ClinicalTrials.gov Identifier: NCT02290457 Registered 13 November 2014.

  12. Is handgrip strength normalized to body weight a useful tool to identify dynapenia and functional incapacity in post-menopausal women?

    PubMed

    Dulac, Maude; Boutros, Guy El Hajj; Pion, Charlotte; Barbat-Artigas, Sébastien; Gouspillou, Gilles; Aubertin-Leheudre, Mylène

    2016-01-01

    To investigate whether handgrip strength normalized to body weight could be a useful clinical tool to identify dynapenia and assess functional capacity in post-menopausal women. A total of 136 postmenopausal women were recruited. Body composition (Dual Energy X-ray Absorptiometry [DEXA], Bio-electrical Impedence Analysis [BIA]), grip strength (dynamometer) and functional capacity (senior fitness tests) were evaluated. Dynapenia was established according to a handgrip strength index (handgrip strength divided by body weight (BW) in Kg/KgBW) obtained from a reference population of young women: Type I dynapenic (<0.44 kg/KgBW) and type II dynapenic (<0.35 kg/KgBW). The results show a positive correlation between handgrip strength index (in kg/KgBW) and alternate-step test (r=0.30, p<0.001), chair-stand test (r=0.25, p<0.005) and one-leg stance test (r=0.335, p<0.001). The results also showed a significant difference in non-dynapenic compared to type I dynapenic and type II dynapenic for the chair-stand test (Non-dynapenic: 12.0±3.0; Type I: 11.7±2.5; Type II: 10.3±3.0) (p=0.037 and p=0.005, respectively) and the one-leg stance test (Non-dynapenic: 54.2±14.2; Type I: 43.8±21.4; Type II: 35.0±21.8) (p=0.030 and p=0.004, respectively). Finally, a significant difference was observed between type II dynapenic and non-dynapenic for the chair-stand test (p=0.032), but not with type I dynapenic. The results showed that handgrip strength was positively correlated with functional capacity. In addition, non-dynapenic women displayed a better functional status when compared to type I and type II dynapenic women. Thus, the determination of the handgrip strength thresholds could be an accessible and affordable clinical tool to identify people at risk of autonomy loss.

  13. The association of ACE, ACTN3 and PPARA gene variants with strength phenotypes in middle school-age children.

    PubMed

    Ahmetov, Ildus I; Gavrilov, Dmitry N; Astratenkova, Irina V; Druzhevskaya, Anastasiya M; Malinin, Alexandr V; Romanova, Elena E; Rogozkin, Victor A

    2013-01-01

    The aim of the study was to determine the association between ACE I/D, ACTN3 R577X and PPARA intron 7 G/C gene polymorphisms and strength-related traits in 457 middle school-age children (219 boys and 238 girls; aged 11 ± 0.4 years). The assessment of different phenotypes was conducted with a number of performance tests. Gene polymorphisms were determined by PCR. The ACE D allele was associated with high results of standing long-jump test in boys [II 148.3 (16.3) cm, ID 152.6 (19.6) cm, DD 158.2 (19.1) cm; P = 0.037]. The ACTN3 R allele was associated with high results of performance tests in males only in combination with other genes (standing long-jump test: P = 0.021; handgrip strength test: P < 0.0001). Furthermore, the male carriers of the PPARA gene C allele demonstrated the best results of handgrip strength testing than GG homozygotes [GG 14.6 (4.0) kg, GC/CC 15.7 (4.3) kg; P = 0.048]. Thus, the ACE, ACTN3 and PPARA gene variants are associated with strength-related traits in physically active middle school-age boys.

  14. Assessment of Isometric Trunk Strength - The Relevance of Body Position and Relationship between Planes of Movement.

    PubMed

    Kocjan, Andrej; Sarabon, Nejc

    2014-05-01

    The aim of the study was to assess the differences in maximal isometric trunk extension and flexion strength during standing, sitting and kneeling. Additionally, we were interested in correlations between the maximal strength in sagittal, frontal and transverse plane, measured in the sitting position. Sixty healthy subjects (24 male, 36 female; age 41.3 ± 15.1 yrs; body height 1.70 ± 0.09 m; body mass 72.7 ± 13.3 kg) performed maximal voluntary isometric contractions of the trunk flexor and extensor muscles in standing, sitting and kneeling position. The subjects also performed lateral flexions and rotations in the sitting position. Each task was repeated three times and average of maximal forces was used for data analysis. RANOVA with post-hoc testing was applied to the flexion and extension data. The level of statistical significance was set to p < 0.05. Overall, in both genders together, the highest average force for trunk extension was recorded in sitting posture (910.5 ± 271.5 N), followed by kneeling (834.3 ± 242.9 N) and standing (504.0 ± 165.4 N), compared with flexion, where we observed the opposite trend (508.5 ± 213.0 N, 450.9 ± 165.7 N and 443.4 ± 153.1 N, respectively). Post-hoc tests showed significant differences in all extension positions (p < 0.0001) and between sitting/standing (p = 0.018) and kneeling/standing (p = 0.033) flexion exertions. The extension/flexion ratio for sitting was 2.1 ± 0.4, for kneeling 1.9 ± 0.4, followed by standing, where motion forward approximately equals motion backward (1.1 ± 0.6). Trunk sagittal-transverse strength showed the strongest correlation, followed by frontal-transverse and sagittal-frontal plane correlation pairs (R(2) = 0.830, 0.712 and 0.657). The baseline trunk isometric strength data provided by this study should help further strength diagnostics, more precisely, the prevention of low back disorders. Key pointsMaximal voluntary isometric force of the trunk extensors increased with the angle at the hips (highest in sitting, medium in kneeling and lowest in upright standing).The opposite trend was true for isometric MVC force of trunk flexors (both genders together and men only).In the sitting position, the strongest correlation between MVC forces was found between sagittal (average flexion/extension) and transverse plane (average left/right rotation).IN ORDER TO INCREASE THE VALIDITY OF TRUNK STRENGTH TESTING THE LETTER SHOULD INCLUDE: specific warm-up, good pelvic fixation and visual feedback.

  15. Assessment of Isometric Trunk Strength – The Relevance of Body Position and Relationship between Planes of Movement

    PubMed Central

    Kocjan, Andrej; Sarabon, Nejc

    2014-01-01

    The aim of the study was to assess the differences in maximal isometric trunk extension and flexion strength during standing, sitting and kneeling. Additionally, we were interested in correlations between the maximal strength in sagittal, frontal and transverse plane, measured in the sitting position. Sixty healthy subjects (24 male, 36 female; age 41.3 ± 15.1 yrs; body height 1.70 ± 0.09 m; body mass 72.7 ± 13.3 kg) performed maximal voluntary isometric contractions of the trunk flexor and extensor muscles in standing, sitting and kneeling position. The subjects also performed lateral flexions and rotations in the sitting position. Each task was repeated three times and average of maximal forces was used for data analysis. RANOVA with post-hoc testing was applied to the flexion and extension data. The level of statistical significance was set to p < 0.05. Overall, in both genders together, the highest average force for trunk extension was recorded in sitting posture (910.5 ± 271.5 N), followed by kneeling (834.3 ± 242.9 N) and standing (504.0 ± 165.4 N), compared with flexion, where we observed the opposite trend (508.5 ± 213.0 N, 450.9 ± 165.7 N and 443.4 ± 153.1 N, respectively). Post-hoc tests showed significant differences in all extension positions (p < 0.0001) and between sitting/standing (p = 0.018) and kneeling/standing (p = 0.033) flexion exertions. The extension/flexion ratio for sitting was 2.1 ± 0.4, for kneeling 1.9 ± 0.4, followed by standing, where motion forward approximately equals motion backward (1.1 ± 0.6). Trunk sagittal-transverse strength showed the strongest correlation, followed by frontal-transverse and sagittal-frontal plane correlation pairs (R2 = 0.830, 0.712 and 0.657). The baseline trunk isometric strength data provided by this study should help further strength diagnostics, more precisely, the prevention of low back disorders. Key points Maximal voluntary isometric force of the trunk extensors increased with the angle at the hips (highest in sitting, medium in kneeling and lowest in upright standing). The opposite trend was true for isometric MVC force of trunk flexors (both genders together and men only). In the sitting position, the strongest correlation between MVC forces was found between sagittal (average flexion/extension) and transverse plane (average left/right rotation). In order to increase the validity of trunk strength testing the letter should include: specific warm-up, good pelvic fixation and visual feedback. PMID:24790491

  16. The effects of combined elastic- and free-weight tension vs. free-weight tension on one-repetition maximum strength in the bench press.

    PubMed

    Bellar, David M; Muller, Matthew D; Barkley, Jacob E; Kim, Chul-Ho; Ida, Keisuke; Ryan, Edward J; Bliss, Mathew V; Glickman, Ellen L

    2011-02-01

    The present study investigated the effects of training combining elastic tension, free weights, and the bench press. Eleven college-aged men (untrained) in the bench press participated in the 13-week study. The participants were first given instructions and then practiced the bench press, followed by a one-repetition maximum (1RM) test of baseline strength. Subjects were then trained in the bench press for 3 weeks to allow for the beginning of neural adaptation. After another 1RM test, participants were assigned to 1 of 2 conditions for the next 3 weeks of training: 85% Free-Weight Tension, 15% Elastic Tension (BAND), or 100% Free-Weight Tension (STAND). After 3 weeks of training and a third 1RM max test, participants switched treatments, under which they completed the final 3 weeks of training and the fourth 1RM test. Analysis via analysis of covariance revealed a significant (p ≤ 0.05) main effect for time and interaction effect for Treatment (BAND vs. STAND). Subsequent analysis via paired-samples t-test revealed the BAND condition was significantly better (p = 0.05) at producing raw gains in 1RM strength. (BAND 9.95 ± 3.7 kg vs. STAND 7.56 ± 2.8 kg). These results suggest that the addition of elastic tension to the bench press may be an effective method of increasing strength.

  17. Relationship between performance variables and baseball ability in youth baseball players.

    PubMed

    Nakata, Hiroki; Nagami, Tomoyuki; Higuchi, Takatoshi; Sakamoto, Kiwako; Kanosue, Kazuyuki

    2013-10-01

    The present study investigated the relationship of performance variables and anthropometric measurements on baseball ability in 164 youth baseball players (age: 6.4-15.7 years). To evaluate their baseball performance, ball speeds in pitching and batting were recorded and kinetic energies of the pitched and hit balls were calculated. To record anthropometric and physical fitness characteristics, height and weight were measured and a battery of physical fitness tests covering standing long jump, side steps, sit-ups, 10-m sprint, trunk flexion, back strength, and grip strengths of both hands were conducted. The results of a multiple regression analysis revealed several significant predictors: age, body mass index (BMI), standing long jump, 10-m sprint, and grip strength for pitched ball kinetic energy and age, BMI, standing long jump, and back strength for hit ball kinetic energy. This study provides scientific evidence that relates certain specific physical performance tests and body characteristics with high achievement in the actual performance of pitching and batting. Youth players, their parents, coaches, and trainers would benefit by addressing these characteristics when planning training programs to improve the baseball performance of youth players.

  18. Association between leg strength and muscle cross-sectional area of the quadriceps femoris with the physical activity level in octogenarians.

    PubMed

    Latorre-Román, Pedro Á; Arévalo-Arévalo, Juan Manuel; García-Pinillos, Felipe

    2016-06-03

    Aging is a complex physiological process whose main feature is the progressive loss of functionality, which may be delayed or attenuated by improving physical fitness.  To determine the association between leg strength and the muscle cross-sectional area of the quadriceps femoris in relation to physical activity level in the elderly.  Thirty-two functionally autonomous people over 80 years (men: 82.80±2.09 years; women: 83.77±4.09 years) participated in this study. The Barthel Index, the Yale Physical Activity Survey and the Chair Stand Test were the instruments used.  There were significant differences between sexes in muscle area (p<0.001) in the Chair Stand Test (p=0.028) and the walk index (p=0.029), with higher values in men. The muscle area and the Chair Stand Test correlated significantly with the walk index (r=0.445, p<0.005, and r=0.522, p<0.001, respectively) and the total weekly activity index (r=0.430, p<0.005, and r=0.519, p<0.001, respectively). In the multiple linear regression models for the total weekly activity index, muscle area and the Chair Stand Test, only the latter behaved as a predictor variable.  Muscle strength and muscle mass of quadriceps showed a significant association with the physical activity level in older people. Leg muscle strength was useful to reveal muscle mass and physical activity level in older people, which is relevant as a clinical practice indicator.

  19. Association of physical activity with muscular strength and fat-free mass in adolescents: the HELENA study.

    PubMed

    Moliner-Urdiales, Diego; Ortega, Francisco B; Vicente-Rodriguez, Germán; Rey-Lopez, Juan P; Gracia-Marco, Luis; Widhalm, Kurt; Sjöström, Michael; Moreno, Luis A; Castillo, Manuel J; Ruiz, Jonatan R

    2010-08-01

    The objective of this study is to analyse the association of objectively assessed physical activity (PA) with muscular strength and fat-free mass in adolescents, and to determine whether meeting the current PA recommendations is associated with higher levels of muscular strength and fat-free mass. The present cross-sectional study comprised 363 Spanish adolescents (180 females) aged 12.5-17.5 years. PA was assessed by accelerometry and expressed as average PA (counts/min), and min/day of inactive, light, moderate, vigorous and moderate to vigorous PA (MVPA). MVPA was dichotomized into < 60 min/day and > or = 60. Upper body muscular strength was measured with the handgrip strength test, and lower body muscular strength was measured with the standing broad jump, squat jump, counter movement jump and Abalakov tests. Fat-free mass was measured by DXA. We observed positive associations between vigorous PA and all the lower body muscular strength tests except for the counter movement jump in males. PA was not associated with fat-free mass in both males and females. Male adolescents engaged in at least 60 min/day MVPA performed better in the standing broad jump test. In conclusion, the findings of the present study suggest that only vigorous PA is associated with muscular strength, particularly lower-body muscular strength in male adolescents.

  20. [The effect of 24 weeks of moderate-to-high intensity strength training on the elderly].

    PubMed

    Solà Serrabou, Marta; López del Amo, José Luis; Valero, Oliver

    2014-01-01

    Strength programs have been seen to be useful in minimizing the effects of sarcopenia, although intervention protocols may vary in their content and characteristics. The aim of this study was to demonstrate the influence of a particular strength protocol for the elderly. A total of 35 individuals took part in the study, with 18 in the exercise group (4 men and 14 women), and 17 in the control group (4 men and 13 women). The average age was 73. The exercise group carried out a strength training program at moderate to high intensity over 24 weeks. Strength was evaluated using the chair stand test, 2-minute step and 2 vertical jumps-squat jump (SJ), and countermovement jump (CMJ). Falls in both groups were also compared before and after the intervention, as well as their relationship with the chair stand variable. A tendency towards improvement was observed in all tests, with the exception of CMJ; while the control group showed a tendency in the opposite direction. Contrast between the two groups at the end of the intervention was notable in all the tests. An inverse relationship between the chair stand strength variable and the number of falls was evident. According to the results achieved, the training was perceived to exercise a positive influence on both the strength of the elderly people and a reduction of the number of falls. The gap between the two groups widened towards the end of the intervention. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  1. Is handgrip strength normalized to body weight a useful tool to identify dynapenia and functional incapacity in post-menopausal women?

    PubMed Central

    Dulac, Maude; Boutros, Guy El Hajj; Pion, Charlotte; Barbat-Artigas, Sébastien; Gouspillou, Gilles; Aubertin-Leheudre, Mylène

    2016-01-01

    ABSTRACT Objective To investigate whether handgrip strength normalized to body weight could be a useful clinical tool to identify dynapenia and assess functional capacity in post-menopausal women. Method A total of 136 postmenopausal women were recruited. Body composition (Dual Energy X-ray Absorptiometry [DEXA], Bio-electrical Impedence Analysis [BIA]), grip strength (dynamometer) and functional capacity (senior fitness tests) were evaluated. Dynapenia was established according to a handgrip strength index (handgrip strength divided by body weight (BW) in Kg/KgBW) obtained from a reference population of young women: Type I dynapenic (<0.44 kg/KgBW) and type II dynapenic (<0.35 kg/KgBW). Results The results show a positive correlation between handgrip strength index (in kg/KgBW) and alternate-step test (r=0.30, p<0.001), chair-stand test (r=0.25, p<0.005) and one-leg stance test (r=0.335, p<0.001). The results also showed a significant difference in non-dynapenic compared to type I dynapenic and type II dynapenic for the chair-stand test (Non-dynapenic: 12.0±3.0; Type I: 11.7±2.5; Type II: 10.3±3.0) (p=0.037 and p=0.005, respectively) and the one-leg stance test (Non-dynapenic: 54.2±14.2; Type I: 43.8±21.4; Type II: 35.0±21.8) (p=0.030 and p=0.004, respectively). Finally, a significant difference was observed between type II dynapenic and non-dynapenic for the chair-stand test (p=0.032), but not with type I dynapenic. Conclusion The results showed that handgrip strength was positively correlated with functional capacity. In addition, non-dynapenic women displayed a better functional status when compared to type I and type II dynapenic women. Thus, the determination of the handgrip strength thresholds could be an accessible and affordable clinical tool to identify people at risk of autonomy loss. PMID:27683834

  2. Effect of low-cost resistance training on lower-limb strength and balance in institutionalized seniors.

    PubMed

    Motalebi, Seyedeh Ameneh; Cheong, Loke Seng; Iranagh, Jamileh Amirzadeh; Mohammadi, Fatemeh

    2018-01-01

    Background/Study Context: Given the rapid increase in the aging population worldwide, fall prevention is of utmost importance. It is essential to establish an efficient, simple, safe, and low-cost intervention method for reducing the risk of falls. This study examined the effect of 12 weeks of progressive elastic resistance training on lower-limb muscle strength and balance in seniors living in the Rumah Seri Kenangan, social welfare home in Cheras, Malaysia. A total of 51 subjects qualified to take part in this quasi-experimental study. They were assigned to either the resistance exercise group (n = 26) or control group (n = 25). The mean age of the 45 participants who completed the program was 70.7 (SD = 6.6). The exercise group met twice per week and performing one to three sets of 8 to 10 repetitions for each of nine lower-limb elastic resistance exercises. All exercises were conducted at low to moderate intensities in sitting or standing positions. The subjects were tested at baseline and 6 and 12 weeks into the program. The results showed statistically significant improvements in lower-limb muscle strength as measured by five times sit-to-stand test (%Δ = 22.6) and dynamic balance quantified by the timed up-and-go test (%Δ = 18.7), four-square step test (%Δ = 14.67), and step test for the right (%Δ = 18.36) and left (%Δ = 18.80) legs. No significant changes were observed in static balance as measured using the tandem stand test (%Δ = 3.25), and one-leg stand test with eyes opened (%Δ = 9.58) and eyes closed (%Δ = -0.61) after completion of the program. The findings support the feasibility and efficacy of a simple and inexpensive resistance training program to improve lower-limb muscle strength and dynamic balance among the institutionalized older adults.

  3. Health-related physical fitness assessment in a community-based cancer rehabilitation setting.

    PubMed

    Kirkham, Amy A; Neil-Sztramko, Sarah E; Morgan, Joanne; Hodson, Sara; Weller, Sarah; McRae, Tasha; Campbell, Kristin L

    2015-09-01

    Assessment of physical fitness is important in order to set goals, appropriately prescribe exercise, and monitor change over time. This study aimed to determine the utility of a standardized physical fitness assessment for use in cancer-specific, community-based exercise programs. Tests anticipated to be feasible and suitable for a community setting and a wide range of ages and physical function were chosen to measure body composition, aerobic fitness, strength, flexibility, and balance. Cancer Exercise Trainers/Specialists at cancer-specific, community-based exercise programs assessed new clients (n = 60) at enrollment, designed individualized exercise programs, and then performed a re-assessment 3-6 months later (n = 34). Resting heart rate, blood pressure, body mass index, waist circumference, handgrip strength, chair stands, sit-and-reach, back scratch, single-leg standing, and timed up-and-go tests were considered suitable and feasible tests/measures, as they were performed in most (≥88 %) participants. The ability to capture change was also noted for resting blood pressure (-7/-5 mmHg, p = 0.02), chair stands (+4, p < 0.01), handgrip strength (+2 kg, p < 0.01), and sit-and-reach (+3 cm, p = 0.03). While the submaximal treadmill test captured a meaningful improvement in aerobic fitness (+62 s, p = 0.17), it was not completed in 33 % of participants. Change in mobility, using the timed up-and-go was nominal and was not performed in 27 %. Submaximal treadmill testing, handgrip dynamometry, chair stands, and sit-and-reach tests were feasible, suitable, and provided meaningful physical fitness information in a cancer-specific, community-based, exercise program setting. However, a shorter treadmill protocol and more sensitive balance and upper body flexibility tests should be investigated.

  4. 76 FR 13580 - Bus Testing; Calculation of Average Passenger Weight and Test Vehicle Weight

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... occupied per standing passenger from 1.5 to 1.75 square feet, and updating the Structural Strength and... standing passenger from 1.5 square feet of free floor space to 1.75 square feet of free floor space to... (assumed to be each 1.75 square foot of free floor space). * * * * * 3. Amend Appendix A to part 665 by...

  5. A study of the relationship between depression symptom and physical performance in elderly women.

    PubMed

    Lee, Yang Chool

    2015-12-01

    Depression is a general public health problem; there is an association between regular exercise or vigorous physical activity and depression. Physical activity has positive physical, mental, and emotional effects. The purpose of this study was to examine the relationship between depression symptom and physical performance in elderly women. A total of 173 elderly women aged 65 to 80 participated in this study. We evaluated elderly women using the 6-min walk, grip-strength, 30-sec arm curl, 30-sec chair stand, 8-foot up and go, back scratch, and chair sit and reach, and unipedal stance, measured the body mass index (BMI), and depression symptom assessed using Korean version of the Geriatric Depression Scale (GDS-K). The collected data were analyzed using descriptive statistics, correlation analysis, paired t-tests, and simple linear regression using IBM SPSS Statistics ver. 21.0. There were significant correlations between GDS-K and the 6-min walk, 30-sec chair stand, 30-sec arm curl, chair sit and reach, 8-foot up and go, and grip strength tests (P<0.05), but not BMI, back strength, and unipedal stance. When divided into two groups (GDS-K score≥14 and GDS-K score<14), there was a difference between the two groups in the 6-min walk, 30-sec chair stand, 30-sec arm curl test, chair sit and reach, 8-foot up and go test, and grip strength test performances. Physical performance factors were strongly associated with depression symptom, suggesting that physical performance improvements may play an important role in preventing depression.

  6. A study of the relationship between depression symptom and physical performance in elderly women

    PubMed Central

    Lee, Yang Chool

    2015-01-01

    Depression is a general public health problem; there is an association between regular exercise or vigorous physical activity and depression. Physical activity has positive physical, mental, and emotional effects. The purpose of this study was to examine the relationship between depression symptom and physical performance in elderly women. A total of 173 elderly women aged 65 to 80 participated in this study. We evaluated elderly women using the 6-min walk, grip-strength, 30-sec arm curl, 30-sec chair stand, 8-foot up and go, back scratch, and chair sit and reach, and unipedal stance, measured the body mass index (BMI), and depression symptom assessed using Korean version of the Geriatric Depression Scale (GDS-K). The collected data were analyzed using descriptive statistics, correlation analysis, paired t-tests, and simple linear regression using IBM SPSS Statistics ver. 21.0. There were significant correlations between GDS-K and the 6-min walk, 30-sec chair stand, 30-sec arm curl, chair sit and reach, 8-foot up and go, and grip strength tests (P<0.05), but not BMI, back strength, and unipedal stance. When divided into two groups (GDS-K score≥14 and GDS-K score<14), there was a difference between the two groups in the 6-min walk, 30-sec chair stand, 30-sec arm curl test, chair sit and reach, 8-foot up and go test, and grip strength test performances. Physical performance factors were strongly associated with depression symptom, suggesting that physical performance improvements may play an important role in preventing depression. PMID:26730389

  7. EFFECTS OF STRENGTH TRAINING ON PHYSICAL FUNCTION: INFLUENCE OF POWER, STRENGTH, AND BODY COMPOSITION

    PubMed Central

    Hanson, Erik D.; Srivatsan, Sindhu R.; Agrawal, Siddhartha; Menon, Kalapurakkal S.; Delmonico, Matthew J.; Wang, Min Q.; Hurley, Ben F.

    2010-01-01

    The purpose of this study was to determine (a) the effects of strength training (ST) on physical function and (b) the influence of strength, power, muscle volume (MV), and body composition on physical function. Healthy, inactive adults (n = 50) aged 65 years and older underwent strength, power, total body composition (% fat and fat free mass [FFM]), and physical function testing before and after 22 weeks of ST. Physical function testing consisted of tasks designed to mimic common physical activities of daily living (ADL). To improve internal validity of the assessment of mid-thigh intermuscular fat, subcutaneous fat, and knee extensors MV, a 10-week unilateral ST program using the untrained leg as an internal control preceded 12 weeks of whole-body ST. Strength, power, and FFM increased significantly with ST (all p < 0.05), whereas rapid walk, 5 chair stands, and get up and go time decreased significantly with ST in the overall group (all p < 0.05). Women improved significantly in both walking test times (both p < 0.05) but not in the stair climb test, whereas men improved in the stair climb test (p < 0.05) but not in walking test times. Multiple regression analysis revealed the highest R2 (0.28) for the change in chair stands time, followed by stair climb and usual walk at 0.27 and 0.21, respectively. ST improves performance in functional tasks important for ADLs. Changes in strength, power, and FFM are predictors of ST-induced improvements in these tasks. PMID:19910811

  8. Low Physical Fitness Levels in Older Adults with ID: Results of the HA-ID Study

    ERIC Educational Resources Information Center

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Physical fitness is as important to aging adults with ID as in the general population, but to date, the physical fitness levels of this group are unknown. Comfortable walking speed, muscle strength (grip strength), muscle endurance (30 s Chair stand) and cardiorespiratory endurance (10 m incremental shuttle walking test) were tested in a sample of…

  9. Two pilot studies of the effect of bicycling on balance and leg strength among older adults.

    PubMed

    Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna

    2013-01-01

    Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Study 1: a cross-sectional survey of 43 adults aged 44-79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49-72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Cycling by healthy older adults appears promising for improving risk factors for falls.

  10. Two Pilot Studies of the Effect of Bicycling on Balance and Leg Strength among Older Adults

    PubMed Central

    Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna

    2013-01-01

    Objectives. Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Methods. Study 1: a cross-sectional survey of 43 adults aged 44–79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49–72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Results. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Conclusions. Cycling by healthy older adults appears promising for improving risk factors for falls. PMID:23690805

  11. Strength, Fracture Toughness, Fatigue, and Standardization Issues of Free-standing Thermal Barrier Coatings

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Zhu, Dong-Ming; Miller, Robert A.

    2003-01-01

    Strength, fracture toughness and fatigue behavior of free-standing thick thermal barrier coatings of plasma-sprayed ZrO2-8wt % Y2O3 were determined at ambient and elevated temperatures in an attempt to establish a database for design. Strength, in conjunction with deformation (stress-strain behavior), was evaluated in tension (uniaxial and trans-thickness), compression, and uniaxial and biaxial flexure; fracture toughness was determined in various load conditions including mode I, mode II, and mixed modes I and II; fatigue or slow crack growth behavior was estimated in cyclic tension and dynamic flexure loading. Effect of sintering was quantified through approaches using strength, fracture toughness, and modulus (constitutive relations) measurements. Standardization issues on test methodology also was presented with a special regard to material's unique constitutive relations.

  12. Age and gender differences regarding physical performance in the elderly from Barbados and Cuba.

    PubMed

    Rodrigues-Barbosa, Aline; de Miranda, Leticia Miranda; Vieira-Guimarães, Alexsander; Xavier-Corseuil, Herton; Weber-Corseuil, Marui

    2011-02-01

    Presenting physical performance tests' (PPTs) descriptive reference values and prevalence according to gender and age-group regarding a representative sample of non-institutionalised older adults (aged 60 and over) living in Bridgetown (Barbados) and Havana (Cuba). This was a cross-sectional, population-based household survey. In Bridgetown and Havana, respectively, 1,508 and 1,905 subjects were examined who had been selected by probabilistic sampling. PPTs included handgrip strength, standing balance, timed repeated "chair stand" and "pick up a pen." The results from Bridgetown and Havana showed that values (mean ± standard deviations and percentiles) for men were greater than women in handgrip strength and "chair stand" tests (p≤0.01). Increasing age led to both genders having reduced (p≤0.001) prevalence of people having better results for each test (based on chi-square). Men had proportionately better scores than women in the four tests. The data suggested that younger people and men had better physical performance. Men and women in both countries had differences regarding the prevalence of people unable to perform the tests and better test results, according to the test and age-group. The data provided information about the range of performance that can be expected from people in different ages and helped understand usual rates of change in age-groups.

  13. Testing biomechanical models of human lumbar lordosis variability.

    PubMed

    Castillo, Eric R; Hsu, Connie; Mair, Ross W; Lieberman, Daniel E

    2017-05-01

    Lumbar lordosis (LL) is a key adaptation for bipedalism, but factors underlying curvature variations remain unclear. This study tests three biomechanical models to explain LL variability. Thirty adults (15 male, 15 female) were scanned using magnetic resonance imaging (MRI), a standing posture analysis was conducted, and lumbar range of motion (ROM) was assessed. Three measures of LL were compared. The trunk's center of mass was estimated from external markers to calculate hip moments (M hip ) and lumbar flexion moments. Cross-sectional areas of lumbar vertebral bodies and trunk muscles were measured from scans. Regression models tested associations between LL and the M hip moment arm, a beam bending model, and an interaction between relative trunk strength (RTS) and ROM. Hip moments were not associated with LL. Beam bending was moderately predictive of standing but not supine LL (R 2  = 0.25). Stronger backs and increased ROM were associated with greater LL, especially when standing (R 2  = 0.65). The strength-flexibility model demonstrates the differential influence of RTS depending on ROM: individuals with high ROM exhibited the most LL variation with RTS, while those with low ROM showed reduced LL regardless of RTS. Hip moments appear constrained suggesting the possibility of selection, and the beam model explains some LL variability due to variations in trunk geometry. The strength-flexibility interaction best predicted LL, suggesting a tradeoff in which ROM limits the effects of back strength on LL. The strength-flexibility model may have clinical relevance for spinal alignment and pathology. This model may also suggest that straight-backed Neanderthals had reduced lumbar mobility. © 2017 Wiley Periodicals, Inc.

  14. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  15. Digit ratio (2D:4D) and physical fitness (Eurofit test battery) in school children.

    PubMed

    Ranson, R; Stratton, G; Taylor, S R

    2015-05-01

    The relative lengths of the index finger to the ring finger (2D:4D) is sexually dimorphic and is thought to be a correlate of prenatal sex steroids (low 2D:4D=high prenatal testosterone and low prenatal oestrogen). In adults there have been reports that low 2D:4D is consistently associated with high sports performance. To investigate correlations between 2D:4D and fitness levels in children. Right 2D:4D and body size were measured, in addition to flexibility, speed, endurance and strength (Eurofit tests). 922 boys and 835 girls (mean ages (years): 10.8 ± 1.01 and 10.07 ± 1.00 respectively). height, mass, BMI, triceps and subscapular skinfolds, 20 m shuttle run, sit and reach, standing broad jump, hand grip strength, 10 × 5m sprint, and the sit and reach test. Boys significantly outperformed the girls in the 10 × 5m sprints, the 20 m shuttle run, standing broad jump, and hand grip strength. In boys but not girls, 2D:4D was significantly negatively correlated with scores in all these tests except the standing broad jump. In girls but not boys, 2D:4D was significantly positively correlated to stature, mass, BMI and waist circumference. It is suggested that high prenatal testosterone and low prenatal oestrogen (low 2D:4D) is implicated in high sprinting speed, endurance and hand grip strength in boys. In girls low prenatal testosterone and high prenatal oestrogen is associated with large body size. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Influence of Isokinetic Strength Training of Unilateral Ankle on Ipsilateral One-legged Standing Balance of Adults

    PubMed Central

    Son, Sung Min; Kang, Kyung Woo; Lee, Na Kyung; Nam, Seok Hyun; Kwon, Jung Won; Kim, Kyoung

    2013-01-01

    [Purpose] The purpose of the current study was to investigate the changes in one-legged standing balance of the ipsilateral lower limb following unilateral isokinetic strength training. [Subjects and Methods] Thirty healthy adult volunteers were randomly assigned to either a training group or a control group, so that each group included 15 subjects. Subjects in the training group performed unilateral ankle isokinetic exercises of the dominant leg using the Biodex 3 PRO System for a period of four weeks. Ipsilateral one-legged standing balance was evaluated before and after the intervention with three stability indexes of balance using the Biodex System: Anterior-Posterior Stability Index (APSI), Medial-Lateral Stability Index (MLSI), and Overall Stability Index (OSI). [Results] Comparison of pre- and post-test data revealed significant improvements in strength values (dorsiflexion, plantarflexion, eversion, and inversion) and stability indexes (APSI, MLSI, OSI). [Conclusion] These results suggest that ankle strengthening exercise can be considered as a form of exercise that may assist individuals with improvement of balance. PMID:24259783

  17. Threshold values of physical performance tests for locomotive syndrome.

    PubMed

    Muramoto, Akio; Imagama, Shiro; Ito, Zenya; Hirano, Kenichi; Tauchi, Ryoji; Ishiguro, Naoki; Hasegawa, Yukiharu

    2013-07-01

    Our previous study determined which physical performance tests were the most useful for evaluating locomotive syndrome. Our current study establishes reference values for these major physical performance tests with regards to diagnosing and assessing risk of locomotive syndrome (LS). We measured timed-up-and-go test, one-leg standing time, back muscle strength, grip strength, 10-m gait time and maximum stride in 406 individuals (167 men, 239 women) between the ages of 60-88 years (mean 68.8 ± 6.7 years) during Yakumo Study 2011-12. The LS was defined as having a score of >16 points on the 25-Question Geriatric Locomotive Function Scale (GLFS-25). The reference value of each physical test was determined using receiver operating characteristics analysis. Women had a significantly higher prevalence of LS than men did and also scored significantly higher on the GLFS-25: women, 9.2 ± 10.3 pts; men, 6.7 ± 8.0 pts. Both genders in the non-LS group performed significantly better in all physical performance test gender except for back muscle strength in men and grip strength in both genders than those in the LS group, even after adjusting for age. The results of all the physical performance tests correlated significantly with the GLFS-25 scores of both genders even after adjusting for age except for grip strength. Reference values for TUG, one-leg standing time, back muscle strength, 10-m gait time, maximum stride and grip strength in men were 6.7 s, 21 s, 78 kg, 5.5 s and, 119 cm and 34 kg, respectively, and those for women were 7.5 s, 15 s, 40 kg, 6.2 s, 104 cm, and 22 kg, respectively. We established reference values for major physical performance tests used when assessing locomotive syndrome as defined by the GLFS-25. Our results can be used to characterize physical function and to help tailor an anti-LS training program for each individual.

  18. Relationship between built environment attributes and physical function in Japanese community-dwelling older adults.

    PubMed

    Soma, Yuki; Tsunoda, Kenji; Kitano, Naruki; Jindo, Takashi; Tsuji, Taishi; Saghazadeh, Mahshid; Okura, Tomohiro

    2017-03-01

    To explore the relationships between the built environment and older adults' physical function. The present cross-sectional study carried out in 2010-2012 used data drawn from 509 community-dwelling older adults aged 65-86 years living in Kasama City, a Japanese rural region. We evaluated physical function with the following performance tests: grip strength, sit-to-stand, timed up & go and walking speed. Using geographic information systems, we measured population density and the number of destinations related to daily life, community centers, medical facilities and recreational facilities within participants' neighborhoods. After adjusting for potential confounders, we found lower population density was related to poor performance of sit-to-stand and walking speed in both sexes, and grip strength in women (trend P < 0.05). A lower number of daily life-related destinations was related to poor performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. Similarly, the number of community centers was related to walking speed in both sexes. The number of medical and recreational facilities was also related to some physical performance in both sexes. A lower land use mix score, calculated by principal component analysis, was related to lower performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. The present study suggests that, although there are some sex differences, low population density, land use mix, and fewer daily life-related destinations, community centers, medical facilities and recreational facilities are negative determinants of physical function. Geriatr Gerontol Int 2017; 17: 382-390. © 2016 Japan Geriatrics Society.

  19. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    PubMed

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  20. Elastic and fracture properties of free-standing amorphous ALD Al2O3 thin films measured with bulge test

    NASA Astrophysics Data System (ADS)

    Rontu, Ville; Nolvi, Anton; Hokkanen, Ari; Haeggström, Edward; Kassamakov, Ivan; Franssila, Sami

    2018-04-01

    We have investigated elastic and fracture properties of amorphous Al2O3 thin films deposited by atomic layer deposition (ALD) with bulge test technique using a free-standing thin film membrane and extended applicability of bulge test technique. Elastic modulus was determined to be 115 GPa for a 50 nm thick film and 170 GPa for a 15 nm thick film. Residual stress was 142 MPa in the 50 nm Al2O3 film while it was 116 MPa in the 15 nm Al2O3 film. Density was 3.11 g cm‑3 for the 50 nm film and 3.28 g cm‑3 for the 15 nm film. Fracture strength at 100 hPa s‑1 pressure ramp rate was 1.72 GPa for the 50 nm film while for the 15 nm film it was 4.21 GPa, almost 2.5-fold. Fracture strength was observed to be positively strain-rate dependent. Weibull moduli of these films were very high being around 50. The effective volume of a circular film in bulge test was determined from a FEM model enabling future comparison of fracture strength data between different techniques.

  1. Functional heterogeneity and outcomes in community-dwelling women with osteoporosis, with and without a history of falls.

    PubMed

    Pua, Yong-Hao; Ong, Peck-Hoon; Lim, Edwin Choon-Wyn; Huang, Katherin Shilin; Clark, Ross A; Chandran, Manju

    2014-03-01

    Falls leading to osteoporotic fracture is a substantial issue clinically. By inference from the literature, women with osteoporosis who are classified as having a history of falls may not represent a distinct homogeneous population. However, studies exploring the potential heterogeneity within fallers in women with osteoporosis are scarce. The objective of this study was to better understand the physical function characteristics of women with osteoporosis, with and without a previous history of falls, by further stratifying them based on their single-leg stance (SLS) performance. Eighty-seven consecutive, community-dwelling women with osteoporosis were recruited from the Endocrinology Clinic at Singapore General Hospital. Laboratory-based and clinic-based standing balance tests, a lower limb strength test, and the 6-min walk test (6MWT) were measured. Fallers and non-fallers did not differ in standing balance, lower limb strength nor the 6MWT (P's>0.08). SLS performance was an independent predictor of the various functional measures, after adjusting for age and body mass index. Specifically, an increase in SLS time was associated with lower standing center-of-pressure velocities, greater lower limb strength, and greater 6-min walking distance. When the two groups were stratified based on their recent history of falls and clinic-based standing balance performance (SLS time), fallers with good SLS time (>30 s) showed better functional outcomes than did non-fallers with poor SLS time (≤30 s) (P's<0.08) and comparable functional outcomes with non-fallers with good SLS time (P's>0.11). The results indicate an important heterogeneity within fallers and non-fallers with osteoporosis and they argue for a individualized approach to rehabilitation. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A Study of relationship between frailty and physical performance in elderly women.

    PubMed

    Jeoung, Bog Ja; Lee, Yang Chool

    2015-08-01

    Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty.

  3. The ACTN3 R577X genotype is associated with muscle function in a Japanese population.

    PubMed

    Kikuchi, Naoki; Yoshida, Shou; Min, Seok-ki; Lee, Kihyuk; Sakamaki-Sunaga, Mikako; Okamoto, Takanobu; Nakazato, Koichi

    2015-04-01

    Homozygosity for the common nonsense polymorphism R577X in the α-actinin-3 gene (ACTN3) causes complete α-actinin-3 deficiency in fast-twitch skeletal muscle fibers. This study investigated whether the ACTN3 R577X polymorphism affects fitness status using a battery of tests in a large Japanese cohort. In the present study, 1227 subjects (age: 25-85 years) were genotyped for the ACTN3 R577X polymorphism (rs1815739) using a TaqMan SNP genotyping assay (Applied Biosystems). All subjects were divided into 2 groups based on their age (<55 years and ≥55 years). All subjects completed a questionnaire about exercise habits and were subjected to a battery of tests to assess their fitness status (including grip strength test, chair stand test, and 8-foot walking test). A significant association between the ACTN3 R577X genotype and chair stand test performance was observed in the group of men ≥55 using ANCOVA adjusted for age and exercise habits (p = 0.036). The ACTN3 R577X genotype accounted for 2.5% of the variability in the results of the chair stand test among men in the ≥55 age group. Moreover, for the ≥55 age group, performance in the chair stand test was lower among those with the XX genotype than among those with the RR genotype (p = 0.024) or RX genotype (p = 0.005), unlike results for the <55 age group. No significant difference was noted for hand grip strength or 8-foot walking time. Thus, our results suggest that the ACTN3 R577X genotype is associated with lower-extremity muscle function in the Japanese population.

  4. A New Approach to Improve Cognition, Muscle Strength, and Postural Balance in Community-Dwelling Elderly with a 3-D Virtual Reality Kayak Program.

    PubMed

    Park, Junhyuck; Yim, JongEun

    2016-01-01

    Aging is usually accompanied with deterioration of physical abilities, such as muscular strength, sensory sensitivity, and functional capacity. Recently, intervention methods with virtual reality have been introduced, providing an enjoyable therapy for elderly. The aim of this study was to investigate whether a 3-D virtual reality kayak program could improve the cognitive function, muscle strength, and balance of community-dwelling elderly. Importantly, kayaking involves most of the upper body musculature and needs the balance control. Seventy-two participants were randomly allocated into the kayak program group (n = 36) and the control group (n = 36). The two groups were well matched with respect to general characteristics at baseline. The participants in both groups performed a conventional exercise program for 30 min, and then the 3-D virtual reality kayak program was performed in the kayak program group for 20 min, two times a week for 6 weeks. Cognitive function was measured using the Montreal Cognitive Assessment. Muscle strength was measured using the arm curl and handgrip strength tests. Standing and sitting balance was measured using the Good Balance system. The post-test was performed in the same manner as the pre-test; the overall outcomes such as cognitive function (p < 0.05), muscle strength (p < 0.05), and balance (standing and sitting balance, p < 0.05) were significantly improved in kayak program group compared to the control group. We propose that the 3-D virtual reality kayak program is a promising intervention method for improving the cognitive function, muscle strength, and balance of elderly.

  5. A comparison of respiratory and peripheral muscle strength, functional exercise capacity, activities of daily living and physical fitness in patients with cystic fibrosis and healthy subjects.

    PubMed

    Arikan, Hulya; Yatar, İlker; Calik-Kutukcu, Ebru; Aribas, Zeynep; Saglam, Melda; Vardar-Yagli, Naciye; Savci, Sema; Inal-Ince, Deniz; Ozcelik, Ugur; Kiper, Nural

    2015-01-01

    There are limited reports that compare muscle strength, functional exercise capacity, activities of daily living (ADL) and parameters of physical fitness of cystic fibrosis (CF) patients with healthy peers in the literature. The purpose of this study was to assess and compare respiratory and peripheral muscle strength, functional exercise capacity, ADL and physical fitness in patients with CF and healthy subjects. Nineteen patients with CF (mean forced expiratory volume in one second-FEV1: 86.56±18.36%) and 20 healthy subjects were included in this study. Respiratory (maximal inspiratory pressure-MIP and maximal expiratory pressure-MEP) and peripheral muscle strength (quadriceps, shoulder abductors and hand grip strength) were evaluated. Functional exercise capacity was determined with 6min walk test (6MWT). ADL was assessed with Glittre ADL test and physical fitness was assessed with Munich fitness test (MFT). There were not any statistically significant difference in MIP, %MIP, MEP and %MEP values between two groups (p>0.05). %Peripheral muscle strength (% quadriceps and shoulder abductors strength), 6MWT distance and %6MWT distance were significantly lower in patients with CF than those of healthy subjects (p<0.05). Glittre ADL-test time was significantly longer in patients with CF than healthy subjects (p<0.05). According to Munich fitness test, the number of bouncing a ball, hanging score, distance of standing vertical jumping and standing vertical jumping score were significantly lower in patients with CF than those of healthy subjects (p<0.05). Peripheral muscle strength, functional exercise capacity, ADL performance and speed, coordination, endurance and power components of physical fitness are adversely affected in mild-severe patients with CF compared to healthy peers. Evaluations must be done in comprehensive manner in patients with CF with all stages. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Factors predicting weight-bearing asymmetry 1month after unilateral total knee arthroplasty: a cross-sectional study.

    PubMed

    Christiansen, Cory L; Bade, Michael J; Weitzenkamp, David A; Stevens-Lapsley, Jennifer E

    2013-03-01

    Factors predicting weight-bearing asymmetry (WBA) after unilateral total knee arthroplasty (TKA) are not known. However, identifying modifiable and non-modifiable predictors of WBA is needed to optimize rehabilitation, especially since WBA is negatively correlated to poor functional performance. The purpose of this study was to identify factors predictive of WBA during sit-stand transitions for people 1month following unilateral TKA. Fifty-nine people were tested preoperatively and 1month following unilateral TKA for WBA using average vertical ground reaction force under each foot during the Five Times Sit-to-Stand Test. Candidate variables tested in the regression analysis represented physical impairments (strength, muscle activation, pain, and motion), demographics, anthropometrics, and movement compensations. WBA, measured as the ratio of surgical/non-surgical limb vertical ground reaction force, was 0.69 (0.18) (mean (SD)) 1month after TKA. Regression analysis identified preoperative WBA (β=0.40), quadriceps strength ratio (β=0.31), and hamstrings strength ratio (β=0.19) as factors predictive of WBA 1month after TKA (R(2)=0.30). Greater amounts of WBA 1month after TKA are predicted by modifiable factors including habitual movement pattern and asymmetry in quadriceps and hamstrings strength. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Reliability and feasibility of physical fitness tests in female fibromyalgia patients.

    PubMed

    Carbonell-Baeza, A; Álvarez-Gallardo, I C; Segura-Jiménez, V; Castro-Piñero, J; Ruiz, J R; Delgado-Fernández, M; Aparicio, V A

    2015-02-01

    The aim of the present study was to determine the reliability and feasibility of physical fitness tests in female fibromyalgia patients. 100 female fibromyalgia patients (aged 50.6±8.6 years) performed the following tests twice (7 days interval test-retest): chair sit and reach, back scratch, handgrip strength, arm curl, chair stand, 8 feet up and go, and 6-min walk. Significant differences between test and retest were found in the arm curl (mean difference: 1.25±2.16 repetitions, Cohen d=0.251), chair stand (0.99±1.7 repetitions, Cohen d=0.254) and 8 feet up and go (-0.38±1.09 s, Cohen d=0.111) tests. Intraclass correlation coefficients (ICC) range from 0.92 in the arm curl test to 0.96 in the back scratch test. The feasibility of the tests (patients able to complete the test) ranged from 89% in the arm curl test to 100% in the handgrip strength test. Therefore, the reliability and feasibility of the physical fitness tests examined is acceptable for female fibromyalgia patients. © Georg Thieme Verlag KG Stuttgart · New York.

  8. The Short Physical Performance Battery is a discriminative tool for identifying patients with COPD at risk of disability.

    PubMed

    Bernabeu-Mora, Roberto; Medina-Mirapeix, Françesc; Llamazares-Herrán, Eduardo; García-Guillamón, Gloria; Giménez-Giménez, Luz María; Sánchez-Nieto, Juan Miguel

    2015-01-01

    Limited mobility is a risk factor for developing chronic obstructive pulmonary disease (COPD)-related disabilities. Little is known about the validity of the Short Physical Performance Battery (SPPB) for identifying mobility limitations in patients with COPD. To determine the clinical validity of the SPPB summary score and its three components (standing balance, 4-meter gait speed, and five-repetition sit-to-stand) for identifying mobility limitations in patients with COPD. This cross-sectional study included 137 patients with COPD, recruited from a hospital in Spain. Muscle strength tests and SPPB were measured; then, patients were surveyed for self-reported mobility limitations. The validity of SPPB scores was analyzed by developing receiver operating characteristic curves to analyze the sensitivity and specificity for identifying patients with mobility limitations; by examining group differences in SPPB scores across categories of mobility activities; and by correlating SPPB scores to strength tests. Only the SPPB summary score and the five-repetition sit-to-stand components showed good discriminative capabilities; both showed areas under the receiver operating characteristic curves greater than 0.7. Patients with limitations had significantly lower SPPB scores than patients without limitations in nine different mobility activities. SPPB scores were moderately correlated with the quadriceps test (r>0.40), and less correlated with the handgrip test (r<0.30), which reinforced convergent and divergent validities. A SPPB summary score cutoff of 10 provided the best accuracy for identifying mobility limitations. This study provided evidence for the validity of the SPPB summary score and the five-repetition sit-to-stand test for assessing mobility in patients with COPD. These tests also showed potential as a screening test for identifying patients with COPD that have mobility limitations.

  9. The Short Physical Performance Battery is a discriminative tool for identifying patients with COPD at risk of disability

    PubMed Central

    Bernabeu-Mora, Roberto; Medina-Mirapeix, Françesc; Llamazares-Herrán, Eduardo; García-Guillamón, Gloria; Giménez-Giménez, Luz María; Sánchez-Nieto, Juan Miguel

    2015-01-01

    Background Limited mobility is a risk factor for developing chronic obstructive pulmonary disease (COPD)-related disabilities. Little is known about the validity of the Short Physical Performance Battery (SPPB) for identifying mobility limitations in patients with COPD. Objective To determine the clinical validity of the SPPB summary score and its three components (standing balance, 4-meter gait speed, and five-repetition sit-to-stand) for identifying mobility limitations in patients with COPD. Methods This cross-sectional study included 137 patients with COPD, recruited from a hospital in Spain. Muscle strength tests and SPPB were measured; then, patients were surveyed for self-reported mobility limitations. The validity of SPPB scores was analyzed by developing receiver operating characteristic curves to analyze the sensitivity and specificity for identifying patients with mobility limitations; by examining group differences in SPPB scores across categories of mobility activities; and by correlating SPPB scores to strength tests. Results Only the SPPB summary score and the five-repetition sit-to-stand components showed good discriminative capabilities; both showed areas under the receiver operating characteristic curves greater than 0.7. Patients with limitations had significantly lower SPPB scores than patients without limitations in nine different mobility activities. SPPB scores were moderately correlated with the quadriceps test (r>0.40), and less correlated with the handgrip test (r<0.30), which reinforced convergent and divergent validities. A SPPB summary score cutoff of 10 provided the best accuracy for identifying mobility limitations. Conclusion This study provided evidence for the validity of the SPPB summary score and the five-repetition sit-to-stand test for assessing mobility in patients with COPD. These tests also showed potential as a screening test for identifying patients with COPD that have mobility limitations. PMID:26664110

  10. Effects of strength training on body composition, physical functioning, and quality of life in prostate cancer patients during androgen deprivation therapy.

    PubMed

    Nilsen, Tormod S; Raastad, Truls; Skovlund, Eva; Courneya, Kerry S; Langberg, Carl W; Lilleby, Wolfgang; Fosså, Sophie D; Thorsen, Lene

    2015-11-01

    Androgen deprivation therapy (ADT) increases survival rates in prostate cancer (PCa) patients with locally advanced disease, but is associated with side effects that may impair daily function. Strength training may counteract several side effects of ADT, such as changes in body composition and physical functioning, which in turn may affect health-related quality of life (HRQOL). However, additional randomised controlled trials are needed to expand this knowledge. Fifty-eight PCa patients on ADT were randomised to either 16 weeks of high-load strength training (n = 28) or usual care (n = 30). The primary outcome was change in total lean body mass (LBM) assessed by dual x-ray absorptiometry (DXA). Secondary outcomes were changes in regional LBM, fat mass, and areal bone mineral density (aBMD) measured by DXA; physical functioning assessed by 1-repetition maximum (1RM) tests, sit-to-stand test, stair climbing test and Shuttle walk test; and HRQOL as measured by the European Organization for the Research and Treatment of Cancer Quality of Life Questionnaire Core 30. No statistically significant effect of high-load strength training was demonstrated on total LBM (p = 0.16), but significant effects were found on LBM in the lower and upper extremities (0.49 kg, p < 0.01 and 0.15 kg, p < 0.05, respectively). Compared to usual care, high-load strength training showed no effect on fat mass, aBMD or HRQOL, but beneficial effects were observed in all 1RM tests, sit-to-stand test and stair climbing tests. Adherence to the training program was 88% for lower body exercises and 84% for upper body exercises. In summary, high-load strength training improved LBM in extremities and physical functioning, but had no effect on fat mass, aBMD, or HRQOL in PCa patients on ADT.

  11. Around Marshall

    NASA Image and Video Library

    1963-09-18

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. This photograph taken September 18, 1963 shows a spherical hydrogen tank being constructed next to the S-IC test stand.

  12. Effects of a recreational ice skating program on the functional mobility of a child with cerebral palsy.

    PubMed

    Walsh, Sharon Fleming; Scharf, Michael G

    2014-04-01

    The purpose of this study was to describe the effects of an ice skating program on the ambulation, strength, posture and balance of a child with cerebral palsy (CP). The subject was a five-year-old female with a diagnosis of CP and a Gross Motor Classification System level of III. The subject was a slow and labored household ambulator on level surfaces with bilateral forearm crutches and bilateral ankle foot orthoses. She was unable to transfer to and from the floor to stand independently, stand unsupported or take steps independently. Until the initiation of this study she was receiving physical therapy services 2×/week. For the purpose of this study she participated in a 1 h/week local ice skating program for people with disabilities for a period of four months. The subject displayed clinically significant improvements in functional mobility including: improved standing posture; independent transfer to and from the floor to stand; maintenance of independent standing for 3 min; independent walking for 10 feet; increased ability to isolate extremity musculature; increased strength; improved Gross Motor Function Measure-88 scores and increased endurance. A subsequent testing session four months after the ice skating program had ended displayed declines but not to pre-intervention levels in muscle strength; ability to transfer to and from the floor to stand; functional mobility and standing balance. The results appear to suggest that the participation in an ice skating program clinically improved this child's functional mobility. Further research needs to be done with regard to physical recreational programs and the benefit they can have on the function of children with activity limitations.

  13. Around Marshall

    NASA Image and Video Library

    1962-07-03

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of July 3, 1963. All four of its tower legs are well underway.

  14. Around Marshall

    NASA Image and Video Library

    1963-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 5, 1963.

  15. n/a

    NASA Image and Video Library

    1962-10-26

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken October 26, 1962, depicts the excavation process of the single engine F-1 stand.

  16. Around Marshall

    NASA Image and Video Library

    1963-09-30

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of September 30, 1963.

  17. Around Marshall

    NASA Image and Video Library

    1963-06-24

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of June 24, 1963. Two if its four tower legs are underway.

  18. n/a

    NASA Image and Video Library

    1962-11-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were built during this time. Built to the north of the massive S-IC test stand, was the F-1 Engine test stand. The F-1 test stand, a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken November 15, 1962, depicts the excavation process of the single engine F-1 stand site.

  19. Around Marshall

    NASA Image and Video Library

    1963-10-22

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Northeast of the massive S-IC test stand, the F-1 Engine test stand was built. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the fuel tanks that housed kerosene and just beyond those is the F-1 test stand.

  20. Somatotype is More Interactive with Strength than Fat Mass and Physical Activity in Peripubertal Children

    PubMed Central

    Marta, Carlos; Marinho, Daniel A.; Costa, Aldo M.; Barbosa, Tiago M.; Marques, Mário C.

    2011-01-01

    The purpose of this study was to analyse the interaction between somatotype, body fat and physical activity in prepubescent children. This was a cross-sectional study design involving 312 children (160 girls, 152 boys) aged between 10 and 11.5 years old (10.8 ± 0.4 years old). Evaluation of body composition was done determining body mass index and body fat by means of skin-fold measurements, using the method described by Slaughter. Somatotype was computed according to the Carter’s method. Physical activity was assessed with the Baecke questionnaire. The physical activity assessment employed sets of curl-ups, push-ups, standing broad jump, medicine ball throw, handgrip strength and Margaria-Kalamen power stair. There were negative associations for body fat, endomorphy and mesomorphy with curl-ups, push-ups and broad jump tests and positive associations with ball throw, handgrip strength and Margaria-Kalamen power tests. The associations for ectomorphy were the inverse of those for endomorphy and mesomorphy. Non obese children presented higher values for curl-ups, push-ups and standing broad jump. In medicine ball throw, handgrip strength and Margaria-Kalamen power test obese children presented higher scores, followed by children who were overweight. The mesoectomorphic boys and ectomesomorphic girls performed higher in all tests. The morphological typology presented more interactions with strength than % of body fat and physical activity. These data seem to suggest that the presence/absence of certain physical characteristics is crucial in the levels of motor provision in prepubescent children. PMID:23486278

  1. Around Marshall

    NASA Image and Video Library

    1963-11-20

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo shows the progress of the F-1 Test Stand as of November 20, 1963.

  2. Around Marshall

    NASA Image and Video Library

    1963-04-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 4, 1963 depicts the construction of the F-1 test stand foundation walls.

  3. Around Marshall

    NASA Image and Video Library

    1963-04-17

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken April 17, 1963 depicts the construction of the F-1 test stand foundation walls.

  4. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults.

    PubMed

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. A Study of relationship between frailty and physical performance in elderly women

    PubMed Central

    Jeoung, Bog Ja; Lee, Yang Chool

    2015-01-01

    Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty. PMID:26331137

  6. Around Marshall

    NASA Image and Video Library

    1962-10-26

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken October 26, 1962, depicts a view of the Block House tunnel opening.

  7. Around Marshall

    NASA Image and Video Library

    1962-08-17

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo taken August 17, 1962 depicts a back side view of the Block House.

  8. Around Marshall

    NASA Image and Video Library

    1962-11-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken November 15, 1962, depicts a view of the Block House.

  9. Around Marshall

    NASA Image and Video Library

    1962-01-23

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photo, taken January 23, 1962, shows the excavation of the Block House site.

  10. Around Marshall

    NASA Image and Video Library

    1962-06-13

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. Construction of the tunnel is depicted in this photo taken June 13, 1962.

  11. Around Marshall

    NASA Image and Video Library

    1962-02-02

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photo, taken February 2, 1962, shows the excavation of the Block House site.

  12. Relationship between lower extremity isometric muscle strength and standing balance in patients with multiple sclerosis.

    PubMed

    Citaker, Seyit; Guclu-Gunduz, Arzu; Yazici, Gokhan; Bayraktar, Deniz; Nazliel, Bijen; Irkec, Ceyla

    2013-01-01

    Muscle strength and standing balance decrease in patients with Multiple Sclerosis (MS). The aim of the present study was to investigate the relationship between the lower extremity isometric muscle strength and standing balance in patients with MS. Forty-seven patients with MS and 10 healthy volunteers were included. Neurological disability level was assessed using Expanded Disability Status Scale (EDSS). Isometric strength of seven lower extremity muscles (hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor) was assessed using hand-held dynamometer. Duration of static one-leg standing balance was measured using digital chronometer. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength, and duration of one-leg standing balance were decreased in patients with MS when compared with controls (p < 0.05). All assessed lower extremity isometric muscle strength and EDSS level was related duration of one-leg standing balance in patients with MS. All assessed lower extremity isometric muscle strength (except ankle dorsal flexor) was related with EDSS. Hip flexor-extensor-abductor-adductor, knee flexor-extensor, and ankle dorsal flexor isometric muscle strength decreases in ambulatory MS patients. Lower extremity muscle weakness and neurological disability level are related with imbalance in MS population. Hip and knee region muscles weakness increases the neurological disability level. For the better balance and decrease neurological disability level whole lower extremity muscle strengthening should be included in rehabilitation programs.

  13. Around Marshall

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. Looking North, this aerial taken January 15, 1963, gives a closer view of the deep hole for the F-1 test stand site in the forefront. The S-IC test stand with towers prominent is to the right of center, and the Block House is seen left of center.

  14. Health-related physical fitness is associated with total and central body fat in preschool children aged 3 to 5 years.

    PubMed

    Martinez-Tellez, B; Sanchez-Delgado, G; Cadenas-Sanchez, C; Mora-Gonzalez, J; Martín-Matillas, M; Löf, M; Ortega, F B; Ruiz, J R

    2016-12-01

    To investigate whether health-related physical fitness is associated with total and central body fat in preschool children. A total of 403 Spanish children aged 3-5 years (57.8% boys) participated in the study. Health-related physical fitness was measured by the PREFIT battery: the handgrip strength and the standing long-jump tests (muscular strength), the 4 × 10 m shuttle run (speed-agility), the one-leg stance tests (balance) and the PREFIT-20 m shuttle run test (cardiorespiratory fitness). Body mass index and waist circumference were used as markers of total and central body fat, respectively. There were significant associations between all health-related physical fitness tests and body mass index (β = 0.280 ± 0.054, β = -0.020 ± 0.006, β = 0.154 ± 0.065 and β = -0.034 ± 0.011 for the handgrip strength, standing long jump, 4 × 10 m shuttle run and PREFIT-20 m shuttle run tests, respectively, all P ≤ 0.019) after adjusting for sex and age. Similarly, there was significant associations of standing long jump (β = -0.072 ± 0.014), 4 × 10 m shuttle run (β = 0.652 ± 0.150) and PREFIT-20 m shuttle run tests (β = -0.102 ± 0.025) with waist circumference (all P ≤ 0.001), except for handgrip strength (β = 0.254 ± 0.145, P = 0.081) and one-leg stance (β = -0.012 ± 0.009, P = 0.156). The present study extends previous findings in older youth. Fitness assessment should be introduced in future epidemiological and intervention studies in preschool children because it seems to be an important factor determining health. © 2015 World Obesity Federation.

  15. Around Marshall

    NASA Image and Video Library

    1961-08-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the test stand as of August 14, 1961.

  16. Around Marshall

    NASA Image and Video Library

    1961-08-18

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the test stand as of August 18, 1961.

  17. Around Marshall

    NASA Image and Video Library

    1963-04-17

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph taken April 17, 1963, gives a look at the four tower legs of the S-IC test stand at their completed height.

  18. Around Marshall

    NASA Image and Video Library

    1961-07-21

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 21, 1961, a worker can be seen inside the test stand work area with a jack hammer.

  19. Around Marshall

    NASA Image and Video Library

    1963-11-20

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of November 20, 1963.

  20. Around Marshall

    NASA Image and Video Library

    1963-06-24

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken June 24, 1963, the four tower legs of the test stand can be seen at their maximum height.

  1. Around Marshall

    NASA Image and Video Library

    1961-07-31

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 31, 1961, work is continued in the clearing of the test stand site.

  2. Around Marshall

    NASA Image and Video Library

    1963-02-25

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph taken February 25, 1963, gives a close up look at two of the ever-growing four towers of the S-IC Test Stand.

  3. Around Marshall

    NASA Image and Video Library

    1961-08-11

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the test stand as of August 11, 1961.

  4. Around Marshall

    NASA Image and Video Library

    1963-05-07

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken from ground level on May 7, 1963, gives a close look at one of the four towers legs of the S-IC test stand nearing its completed height.

  5. Around Marshall

    NASA Image and Video Library

    1963-05-07

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken May 7, 1963, gives a close look at the four concrete tower legs of the S-IC test stand at their completed height.

  6. Around Marshall

    NASA Image and Video Library

    1961-07-21

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 21, 1961, workers can be seen inside the test stand work area clearing the site.

  7. Around Marshall

    NASA Image and Video Library

    1963-10-10

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of October 10, 1963. Kerosene storage tanks can be seen to the left.

  8. Around Marshall

    NASA Image and Video Library

    1961-09-07

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the S-IC test stand as of September 7, 1961.

  9. Construction Progress of the S-IC Test Stand-Steel Reinforcements

    NASA Technical Reports Server (NTRS)

    1961-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 15, 1961, shows the installation of the reinforcing steel prior to the pouring of the concrete foundation walls.

  10. Around Marshall

    NASA Image and Video Library

    1961-07-10

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 10, 1961, actual ground breaking has occurred for the S-IC test stand site.

  11. Around Marshall

    NASA Image and Video Library

    1961-06-30

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this early construction photo, taken June 30, 1961, workers are involved in the survey and site preparation for the test stand.

  12. What is the role of "nonorganic somatic components" in functional capacity evaluations in patients with chronic nonspecific low back pain undergoing fitness for work evaluation?

    PubMed

    Oesch, Peter; Meyer, Kathrin; Jansen, Beatrice; Mowinckel, Petter; Bachmann, Stefan; Hagen, Kare Birger

    2012-02-15

    Analytical cross-sectional study. To assess the association of "nonorganic somatic components" together with physical and other psychosocial factors on functional capacity evaluation (FCE) in patients with chronic nonspecific low back pain (NSLBP) undergoing fitness-for-work evaluation. Functional capacity evaluation is increasingly used for physical fitness-for-work evaluation in patients with chronic NSLBP, but results seem to be influenced by physical as well as psychosocial factors. The influence of nonorganic somatic components together with physical and other psychosocial factors on FCE performance has not yet been investigated. One hundred twenty-six patients with chronic NSLBP referred for physical fitness-for-work evaluation were included. The 4 FCE tests were lifting from floor to waist, forward bend standing, grip strength, and 6-minute walking. Nonorganic somatic components were assessed with the 8 nonorganic somatic signs as defined by Waddell and were adjusted for age, sex, days off work, salary in the previous occupation, pain intensity, fear avoidance belief, and perceived functional ability in multivariate regression analyses. Between 42% and 58% of the variation in the FCE tests was explained in the final multivariate regression models. Nonorganic somatic components were consistent independent predictors for all tests. Their influence was most important on forward bend standing and walking distance, and less on grip strength and lifting performance. The physical factors of age and/or sex were strongly associated with grip strength and lifting, less with walking distance, and not at all with forward bend standing. The influence of at least 1 other psychosocial factor was observed in all FCE tests, having the highest proportion in the 6-minute walking test. Nonorganic somatic components seem to be consistent independent predictors in FCE testing and should be considered for interpretation of test results.

  13. Design and fabrication of a micron scale free-standing specimen for uniaxial micro-tensile tests

    NASA Astrophysics Data System (ADS)

    Tang, Jun; Wang, Hong; Li, Shi Chen; Liu, Rui; Mao, Sheng Ping; Li, Xue Ping; Zhang, Cong Chun; Ding, Guifu

    2009-10-01

    This paper presents a novel design and fabrication of test chips with a nickel free-standing specimen for the micro uniaxial tensile test. To fabricate test chips on the quartz substrate significantly reduces the fabrication time, minimizes the number of steps and eliminates the effect of the wet anisotropic etching process on mechanical properties. The test chip can be gripped tightly to the test machine and aligned accurately in the pulling direction; furthermore, the approximately straight design of the specimen rather than the traditional dog-bone structure enables the strain be directly measured by a displacement sensor. Both finite-element method (FEM) analysis and experimental results indicate the reliability of the new design. The test chip can also be extended to other materials. The experimental measured Young's modulus of a thin nickel film and the ultimate tensile strength are approximately 94.5 Gpa and 1.76 Gpa, respectively. The results were substantially supported by the experiment on larger gauge specimens by a commercial dynamic mechanical analysis (DMA) instrument. These specimens were electroplated under the same conditions. The low Young's modulus and the high ultimate tensile strength might be explained by the fine grain in the electroplated structure.

  14. Around Marshall

    NASA Image and Video Library

    1963-01-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC test stand, related facilities were constructed during this time frame. Built just north of the massive S-IC test stand was the F-1 Engine test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo, taken January 14, 1963 depicts the F-1 test stand site with hoses pumping excess water from the site.

  15. Factors that Explain the Cancer-Related Insomnia.

    PubMed

    Galiano-Castillo, Noelia; Arroyo-Morales, Manuel; Ariza-Garcia, Angélica; Fernández-Lao, Carolina; Fernández-Fernández, Andrés J; Cantarero-Villanueva, Irene

    2017-07-01

    A better understanding of cancer related insomnia and its relationship with other associated factors is necessary to improve its management. To clarify the relationship between insomnia and treatment related variables, sociodemographic data, health related fitness, pain, anxiety, and depression in breast cancer patients. One hundred twenty-three patients participated in this cross-sectional study. As a primary variable was insomnia using The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 version. Other variables included: stage of treatment, type of treatment, multiple sit to stand test, trunk curl test, 6-min walk test, back muscle strength test, the Brief Pain Inventory short form and the Hospital Anxiety and Depression Scale. Insomnia was negatively associated with the treatment stage (p = 0.01), the 6-min walk test (p = 0.01) and the back muscle strength test (p = 0.01), while it was positively associated with the type of treatment (p = 0.01) and the multiple sit-to-stand test (p = 0.05). In addition, higher levels of insomnia were associated with higher scores on the Brief Pain Inventory short form (p = 0.01) and the Hospital Anxiety and Depression Scale (p = 0.01). Anxiety, type of treatment, back muscle strength, pain severity and stage of treatment were predictors of insomnia, and when they were combined they explained 51.2% of insomnia in our sample. The variability in insomnia related breast cancer is explained by anxiety, type of treatment, pain, treatment stage, and back muscle strength. Clinicians should take these results into account when generating cancer care programs to control pain and health-related-fitness (Registration of Trials NCT01801527). © 2017 Wiley Periodicals, Inc.

  16. Sequencing Effects of Balance and Plyometric Training on Physical Performance in Youth Soccer Athletes.

    PubMed

    Hammami, Raouf; Granacher, Urs; Makhlouf, Issam; Behm, David G; Chaouachi, Anis

    2016-12-01

    Hammami, R, Granacher, U, Makhlouf, I, Behm, DG, and Chaouachi, A. Sequencing effects of balance and plyometric training on physical performance in youth soccer athletes. J Strength Cond Res 30(12): 3278-3289, 2016-Balance training may have a preconditioning effect on subsequent power training with youth. There are no studies examining whether the sequencing of balance and plyometric training has additional training benefits. The objective was to examine the effect of sequencing balance and plyometric training on the performance of 12- to 13-year-old athletes. Twenty-four young elite soccer players trained twice per week for 8 weeks either with an initial 4 weeks of balance training followed by 4 weeks of plyometric training (BPT) or 4 weeks of plyometric training proceeded by 4 weeks of balance training (PBT). Testing was conducted pre- and posttraining and included medicine ball throw; horizontal and vertical jumps; reactive strength; leg stiffness; agility; 10-, 20-, and 30-m sprints; Standing Stork balance test; and Y-Balance test. Results indicated that BPT provided significantly greater improvements with reactive strength index, absolute and relative leg stiffness, triple hop test, and a trend for the Y-Balance test (p = 0.054) compared with PBT. Although all other measures had similar changes for both groups, the average relative improvement for the BPT was 22.4% (d = 1.5) vs. 15.0% (d = 1.1) for the PBT. BPT effect sizes were greater with 8 of 13 measures. In conclusion, although either sequence of BPT or PBT improved jumping, hopping, sprint acceleration, and Standing Stork and Y-Balance, BPT initiated greater training improvements in reactive strength index, absolute and relative leg stiffness, triple hop test, and the Y-Balance test. BPT may provide either similar or superior performance enhancements compared with PBT.

  17. Physical performance and daily walking duration: associations in 1271 women and men aged 65-90 years.

    PubMed

    Rapp, Kilian; Klenk, Jochen; Benzinger, Petra; Franke, Sebastian; Denkinger, Michael D; Peter, Richard

    2012-10-01

    Several tests of physical performance like gait speed or standing balance are part of the geriatric assessment. Measures of physical activity like daily walking duration are more difficult to assess but may be of higher relevance for daily requirements. It is therefore of interest to what extent physical performance measures are associated with physical activity. In a cohort study, baseline screening was performed in 1271 community-living people aged 65-90 years from Ulm, Germany. Average daily walking duration was assessed in all participants by accelerometers over a one-week period. Habitual gait speed, 5-Chair-Rise test, standing balance and handgrip strength served as measures of physical performance. The association between measures of physical performance and physical activity was calculated by linear regression analysis. The mean daily walking duration was 104.8 minutes in men and 103.0 minutes in women. A positive relationship between gait speed and walking duration was observed in men and women with low gait speed (≤0.8 m/s) but not in participants above this threshold. Standing balance and hand grip strength were positively and 5-Chair-Rise test inversely related with average daily walking duration. A relationship between hand grip strength and walking duration was only observed in women aged 75 years and more. Physical performance measures and objectively measured walking duration are related with each other but only a small percentage of the variance of daily walking duration was explained by physical performance measures. Therefore, factors other than physical performance seem to influence daily walking duration to a great extent.

  18. Testing the Hip Abductor Muscle Strength of Older Persons Using a Handheld Dynamometer.

    PubMed

    Awwad, Daniel H; Buckley, Jonathan D; Thomson, Rebecca L; O'Connor, Matthew; Carbone, Tania A; Chehade, Mellick J

    2017-09-01

    To investigate the reliability of a clinically applicable method of dynamometry to assess and monitor hip abductor muscle strength in older persons. Bilateral isometric hip abductor muscle strength measured with a handheld dynamometer, patients supine with the contralateral hip positioned directly against a wall for stabilization. Reliability determined by comparing intra-assessor and inter-assessor results and comparison to a criterion standard (stabilized dynamometer with patients in the standing position). UniSA Nutritional Physiology Research Centre. Twenty-one patients older than 65 years were recruited from the Royal Adelaide Hospital. Intraclass correlation coefficients (ICCs), bias, and limits of agreement calculated to determine reliability. Intra-assessor and inter-assessor ICCs were high (0.94 and 0.92-0.94, respectively). There was no intra-assessor bias and narrow limits of agreement (±2.4%). There was a small inter-assessor bias but narrow limits of agreement (0.6%-0.9% and ± 2.3%, respectively). There was a wide variation comparing results to the criterion standard (±5.0%-5.2% limits of agreement), highlighting problems attributed to difficulties that the test population had with the standing position used in the criterion standard test. Testing older persons' hip abductor muscle strength while in the supine position with optimal pelvic stabilization using a handheld dynamometer is highly reliable. While further studies must be done to assess patients with specific pathologies, this test has potential application to monitor and evaluate the effects of surgical interventions and/or rehabilitation protocols for a variety of conditions affecting hip abductor function such as hip fractures and arthritis.

  19. n/a

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963, gives a close overall view of the newly developed test complex. Depicted in the forefront center is the S-IC test stand with towers prominent, the Block House is seen in the center just above the S-IC test stand, and the large hole to the left, located midway between the two is the F-1 test stand site.

  20. Inflammation and nutritional status as predictors of physical performance and strength loss during hospitalization.

    PubMed

    Rossi, A P; Zanandrea, V; Zoico, E; Zanardo, M; Caliari, C; Confente, S; Gabriele, S; Mazzali, G; Fantin, F; Zamboni, M

    2016-12-01

    The aim of this study was to examine changes in physical performance and handgrip strength during hospitalization as well as to evaluate their interrelationship with inflammatory and nutritional status. Data were available on 302 elderly patients with a mean age of 80.83±7.14 years. Handgrip strength, gait speed and chair-stand test were assessed at admission and before discharge. In all subjects, serum CRP values and Mini Nutritional Assessment scores were also evaluated. The risk of worsening in chair-stand test performance was 4.2 (95% confidence interval (CI): 1.574-11.310) for subjects with simultaneous presence of malnutrition and CRP⩾50 and 3.3 mg/dl (95% CI: 1.127-9.423) for subjects with CRP⩾50 mg/l not malnourished in comparison with subjects with Mini Nutritional Assessment (MNA)⩾24 and CRP⩽10 mg/l. The risk of handgrip strength loss was 8.8 (95% CI: 3.545-21.662) in subjects with simultaneous presence of malnutrition and CRP⩾50 and 2.9  mg/dl (95% CI: 1.223-6.783) in subjects with CRP⩾50 mg/l not malnourished in comparison with subjects with MNA⩾24 and CRP⩽10 mg/l. Simultaneous presence of high CRP values and malnutrition determines an additive effect on muscle strength loss and physical performance.

  1. Around Marshall

    NASA Image and Video Library

    1963-02-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This photograph taken February 4, 1963, gives an impressive look at the Block House looking directly through the ever-growing four towers of the S-IC Test Stand.

  2. Around Marshall

    NASA Image and Video Library

    1963-08-13

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. North of the massive S-IC test stand, the F-1 Engine test stand was built. Designed to assist in the development of the F-1 Engine, the F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base. Capability was provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This photo depicts the construction of the F-1 test stand as of August 13, 1963. All four of its tower legs are well underway into the skyline.

  3. n/a

    NASA Image and Video Library

    1963-01-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. The F-1 Engine test stand was built north of the massive S-IC test stand. The F-1 test stand is a vertical engine firing test stand, 239 feet in elevation and 4,600 square feet in area at the base, and was designed to assist in the development of the F-1 Engine. Capability is provided for static firing of 1.5 million pounds of thrust using liquid oxygen and kerosene. Like the S-IC stand, the foundation of the F-1 stand is keyed into the bedrock approximately 40 feet below grade. This aerial photograph, taken January 15, 1963 gives an overall view of the construction progress of the newly developed test complex. The large white building located in the center is the Block House. Just below and to the right of it is the S-IC test stand. The large hole to the left of the S-IC stand is the F-1 test stand site.

  4. Around Marshall

    NASA Image and Video Library

    1963-01-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, depicts the progress of the stand as of January 14, 1963, with its four towers prominently rising.

  5. Comparison of performance-based measures among native Japanese, Japanese-Americans in Hawaii and Caucasian women in the United States, ages 65 years and over: a cross-sectional study

    PubMed Central

    Aoyagi, Kiyoshi; Ross, Philip D; Nevitt, Michael C; Davis, James W; Wasnich, Richard D; Hayashi, Takuo; Takemoto, Tai-ichiro

    2001-01-01

    Background Japanese (both in Japan and Hawaii) have a lower incidence of falls and of hip fracture than North American and European Caucasians, but the reasons for these differences are not clear. Subjects and Methods A cross-sectional study. We compared neuromuscular risk factors for falls using performance-based measures (chair stand time, usual and rapid walking speed, and grip strength) among 163 Japanese women in Japan, 681 Japanese-American women in Hawaii and 9403 Caucasian women in the United States aged 65 years and over. Results After adjusting for age, the Caucasian women required about 40% more time to complete 5 chair stands than either group of Japanese. Walking speed was about 10% slower among Caucasians than native Japanese, whereas Japanese-American women in Hawaii walked about 11% faster than native Japanese. Grip strength was greatest in Japan, which may reflect the rural farming district that this sample was drawn from. Additional adjustment for height, weight or body mass index increased the adjusted means of chair stand time and grip strength among Japanese, but the differences remained significant. Conclusions Both native Japanese and Japanese-American women in Hawaii performed better than Caucasians on chair stand time and walking speed tests, and native Japanese had greater grip strength than Japanese in Hawaii and Caucasians. The biological implications of these differences in performance are uncertain, but may be useful in planning future comparisons between populations. PMID:11696243

  6. Effects of resistance training, detraining, and retraining on strength and functional capacity in elderly.

    PubMed

    Sakugawa, Raphael Luiz; Moura, Bruno Monteiro; Orssatto, Lucas Bet da Rosa; Bezerra, Ewertton de Souza; Cadore, Eduardo Lusa; Diefenthaeler, Fernando

    2018-05-17

    The interruption of training (detraining) results in loss of the gains acquired. Partial retention could occur after detraining, and variation in training stimuli may optimize retraining adaptations. To evaluate the effect of a resistance-retraining program on strength and functional capacity performance after a detraining period. Ten elderly men and women (63-68 years) completed 12 weeks of training, 16 weeks of detraining, and 8 weeks of retraining. One-repetition maximum (1-RM) at 45° leg press, maximum isometric knee extension torque, rate of torque development (RTD), 30-s sit-to-stand, timed up and go, and stair ascent and descent tests were assessed. The 1-RM increased after training (p < 0.01) and remained higher after a detraining period when compared to pre-training (p < 0.01). Post-retraining values were not different from post-training period (p > 0.05). For RTD and 30-s sit-to-stand, there was an increase after retraining when compared to pre-training values (p < 0.05). For timed up and go and stair ascent and descent, reductions were observed between pre-training and post-training periods (p < 0.05), only timed up and go increased after the detraining period (p < 0.01). After 16 weeks of detraining, the maximum strength did not return to baseline levels, and a retraining with explosive strength exercise sessions can recover maximum strength gains, RTD, and functional capacity at the same level obtained after a detraining period. The inclusion of an explosive strength session in retraining period improves RTD and 30-s sit-to-stand performance and can accelerate the recovery of strength after a detraining period.

  7. Around Marshall

    NASA Image and Video Library

    1962-10-08

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo, taken October 8, 1962, depicts a front view of the Block House nearing completion.

  8. Construction Progress of the S-IC Test Stand Complex Bunker House

    NASA Technical Reports Server (NTRS)

    1963-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the S-IC stand, additional related facilities were built during this time frame. Built to the east of the S-IC stand, the block house served as the control room. To the south of the blockhouse was a newly constructed pump house used for delivering water to the S-IC stand during testing. North of the massive test stand, the F-1 Engine test stand was built for testing a single F-1 engine. Just southeast of the S-IC stand a concrete bunker house was constructed. The bunker housed an emergency crew clad in fire proof gear, who were close at hand should any emergencies arise during testing. This photo of the completed bunker house was taken on May 7, 1963.

  9. Effectiveness of virtual reality using video gaming technology in elderly adults with diabetes mellitus.

    PubMed

    Lee, Sunwoo; Shin, Sungrae

    2013-06-01

    Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. Fifty-five subjects with diabetes mellitus over 65 years of age were randomly assigned to a VRE group (VREG) (n=27) and a control group (CG) (n=28). The VREG received the VRE program and diabetes education, whereas the CG received only the diabetes education. The VRE program used video gaming (PlayStation(®) 2; Sony, Tokyo, Japan) and was conducted for 50 min twice a week for 10 weeks. Balance, muscle strength, gait, and falls efficacy were measured at baseline and after intervention. Measurements were taken using a clinical tests (the one-leg-standing test, the Berg Balance Scale, the functional reach test, the timed up-and-go test, and the sit-to-stand test), and gait analysis. A self-administered questionnaire was used to measure falls efficacy. After training, the VREG showed significantly improved balance, decreased sit-to-stand times, and increased gait speed, cadence, and falls efficacy. The VRE program was to maximize the effects of exercise by triggering players was to be fully immersed into the games and enhanced major influential factors on the falls of subject. This study suggests VRE programs are feasible and effective for reduced the risk of falls in elderly adults with type 2 diabetes.

  10. Physical performance tests after stroke: reliability and validity.

    PubMed

    Maeda, A; Yuasa, T; Nakamura, K; Higuchi, S; Motohashi, Y

    2000-01-01

    To evaluate the reliability and validity of the modified physical performance tests for stroke survivors who live in a community. The subjects included 40 stroke survivors and 40 apparently healthy independent elderly persons. The physical performance tests for the stroke survivors comprised two physical capacity evaluation tasks that represented physical abilities necessary to perform the main activities of daily living, e.g., standing-up ability (time needed to stand up from bed rest) and walking ability (time needed to walk 10 m). Regarding the reliability of tests, significant correlations were confirmed between test and retest of physical performance tests with both short and long intervals in individuals after stroke. Regarding the validity of tests, the authors studied the significant correlations between the maximum isometric strength of the quardriceps muscle and the time needed to walk 10 m, centimeters reached while sitting and reaching, and the time needed to stand up from bed rest. The authors confirmed that there were significant correlations between the instrumental activity of daily living and the time needed to stand up from bed rest, along with the time needed to walk 10 m for the stroke survivors. These physical performance tests are useful guides for evaluating a level of activity of daily living and physical frailty of stroke survivors living in a community.

  11. Around Marshall

    NASA Image and Video Library

    1963-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. In the center portion of this photograph, taken September 5, 1963, the spherical hydrogen storage tanks are being constructed. One of the massive tower legs of the S-IC test stand is visible to the far right.

  12. Yoga leads to multiple physical improvements after stroke, a pilot study.

    PubMed

    Schmid, Arlene A; Miller, Kristine K; Van Puymbroeck, Marieke; DeBaun-Sprague, Erin

    2014-12-01

    To assess change in physical functioning (pain, range of motion (ROM), strength, and endurance) after 8 weeks of therapeutic-yoga. Planned analyses of data from a randomized pilot study of yoga after stroke. University-based research laboratory. People with chronic stroke (N=47) randomized to therapeutic-yoga (n=37) or wait-list control (n=10). 16 sessions of therapeutic yoga (twice a week/8 weeks). Yoga was delivered in a standardized and progressive format with postures, breathing, and meditation, and relaxation in sitting, standing, and supine. Pain was assessed with the PEG, a 3-item functional measure of the interference of pain. ROM included neck and hip active and passive ROM measurements). Upper and lower extremity strength were assessed with the arm curl test and chair-to-stand test, respectively. Endurance was assessed with the 6-minute walk and modified 2-min step test. After a Bonferroni Correction, pain, neck ROM, hip passive ROM, upper extremity strength, and the 6-min walk scores all significantly improved after 8 weeks of engaging in yoga. No changes occurred in the wait-list control group. A group therapeutic-yoga intervention may improve multiple aspects of physical functioning after stroke. Such an intervention may be complementary to traditional rehabilitation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Factors predicting dynamic balance and quality of life in home-dwelling elderly women.

    PubMed

    Karinkanta, S; Heinonen, A; Sievanen, H; Uusi-Rasi, K; Kannus, P

    2005-01-01

    Proper balance seems to be a critical factor in terms of fall prevention among the elderly. The purpose of this cross-sectional study was to examine factors that are associated with dynamic balance and health-related quality of life in home-dwelling elderly women. One hundred and fifty-three healthy postmenopausal women (mean age: 72 years, height: 159 cm, weight: 72 kg) were examined. General health and physical activity were assessed by a questionnaire. Quality of life was measured using a health-related quality of life questionnaire (Rand 36-Item Health Survey 1.0). Dynamic balance (agility) was tested by a figure-of-eight running test. Static balance (postural sway) was tested on an unstable platform. Maximal isometric strength of the leg extensors was measured with a leg press dynamometer. Dynamic muscle strength of lower limbs was tested by measuring ground reaction forces with a force platform during common daily activities (sit-to-stand and step-on-a-stair tests). Concerning physical activity, 33% of the subjects reported brisk exercise (walking, Nordic walking, cross-country skiing, swimming and aquatic exercises) at least twice a week, and 22% some kind of brisk activity once a week in addition to lighter physical exercise. The remaining 45% did not exercise regularly and were classified as sedentary. The correlations of step-on-a-stair and sit-to-stand ground reaction forces, and leg extensor strength to dynamic balance were from -0.32 to -0.43 (the better the strength, the better the balance). In the regression analysis with backward elimination, step-on-a-stair and sit-to-stand ground reaction forces, and leg extensor strength, age, brisk physical activity, number of diseases and dynamic postural stability explained 42% of the variance in the dynamic balance. Similarly, dynamic balance (figure-of-eight running time), number of diseases and walking more than 3 km per day explained 14% of the variance in the quality of life score. Of these, figure-of-eight running time was the strongest predictor of the quality of life score, explaining 9% of its variance. This study emphasizes the concept that in home-dwelling elderly women good muscle strength in lower limbs is crucial for proper body balance and that dynamic balance is an independent predictor of a standardized quality of life estimate. The results provide important and useful information when planning meaningful contents for studies related to fall prevention and quality of life and interventions in elderly women. Copyright (c) 2005 S. Karger AG, Basel.

  14. Effects of high-intensity resistance training on strength, mobility, balance, and fatigue in individuals with multiple sclerosis: a randomized controlled trial.

    PubMed

    Hayes, Heather A; Gappmaier, Eduard; LaStayo, Paul C

    2011-03-01

    Resistance exercise via negative, eccentrically induced work (RENEW) has been shown to be associated with improvements in strength, mobility, and balance in multiple clinical populations. However, RENEW has not been reported for individuals with multiple sclerosis (MS). Nineteen individuals with MS (8 men, 11 women; age mean = 49 ± 11 years; Expanded Disability Status Scale [EDSS] mean = 5.2 ± 0.9) were randomized into either standard exercise (STAND) or standard exercise and RENEW training (RENEW) for 3×/week for 12 weeks. Outcome measures were lower extremity strength (hip/knee flexion and extension, ankle plantar and dorsiflexion, and the sum of these individual values [sum strength]); Timed Up and Go (TUG), 10-m walk, self-selected pace (TMWSS) and maximal-pace (TMWMP), stair ascent (S-A) and descent (S-D) and 6-Minute Walk Test (6MWT), Berg Balance Scale (BBS), Fatigue Severity Scale (FSS). No significant time effects or interactions were observed for strength, TUG, TMWSS, TMWMP, or 6MWT. However, the mean difference in sum strength in the RENEW group was 38.60 (representing a 15% increase) compared to the sum strength observed in the STAND group with a mean difference of 5.58 (a 2% increase). A significant interaction was observed for S-A, S-D, and BBS as the STAND group improved whereas the RENEW group did not improve in these measures. Contrary to results in other populations, the addition of eccentric training to standard exercises did not result in significantly greater lower extremity strength gains in this group of individuals with MS. Further this training was not as effective as standard exercise alone in improving balance or the ability to ascend and descend stairs. Following data collection, reassessment of required sample size indicates we were likely underpowered to detect strength differences between groups.

  15. Pilates improves lower limbs strength and postural control during quite standing in a child with hemiparetic cerebral palsy: A case report study.

    PubMed

    Dos Santos, Adriana Neves; Serikawa, Simoni Sayuri; Rocha, Nelci Adriana Cicuto Ferreira

    2016-08-01

    To verify the effect of Pilates exercises in a child with cerebral palsy (CP) with mild functional impairment. We evaluated average peak torque of ankle and knee extensors/flexors using a Biodex System, using concentric active-assisted test. We also evaluated amplitude of anterior-posterior and of medial-lateral displacement of the CoP and area of oscillation during quite standing with a BERTEC platform. We applied Pilates exercises for eight weeks. Peak torque/body weight of ankle and knee extensors/flexors of both affected and unaffected limbs increased after Pilates. Also, all kinetic variables decreased after Pilates' intervention. After one-month follow-up, isokinetic variable values were higher while kinetic variable values were lower than baseline values. Pilates may be an important rehabilitation technique for children with CP that present mild deficits in motor structures and high functional level, especially when the aims are to improve muscle strength and postural control during quite standing.

  16. Relationship between physical activity, disability, and physical fitness profile in sedentary Latina breast cancer survivors.

    PubMed

    Ortiz, Alexis; Tirado, Maribel; Hughes, Daniel C; Gonzalez, Velda; Song, JaeJoon; Mama, Scherezade K; Basen-Engquist, Karen

    2018-10-01

    To report baseline data from a physical activity (PA) intervention for Latina breast cancer survivors, and assess the relationship between PA, fitness, and disability. Eighty-nine Latina breast cancer survivors from San Juan, PR and Houston, TX (age: 55.4 ± 9.9 years; BMI: 29.87 ± 5.62 kg/m 2 ; ≥ 3 months post-treatment) participated in this study. At baseline participants completed fitness testing (six-minute walk test [6MWT], 30-second sit-stand; grip strength, lower and upper extremity and low back strength, shoulder range of motion, balance testing), and assessment of physical activity (PA) and disability. PA was assessed using the International Physical Activity Questionnaire (IPAQ). A subsample (n = 27) received an accelerometer to compare objective versus self-reported PA. Participants exhibited low PA (M = 76.5 MET·minutes/week; SD = 183.4), poor fitness (6MWT M = 436.4 meters, SD = 99.1; 30s sit-stand, M = 11.6 stands, SD = 3.1), and no detectable disability. In an adjusted model lower extremity fitness was associated with PA, with a one repetition increase in sit-to-stand associated with 49 additional minutes of self-reported PA plus walking per week. The correlation between IPAQ moderate-vigorous PA and accelerometer was 0.38 (p = 0.047). Latina breast cancer survivors have low physical activity and fitness levels that increase their risk of disability, cardiometabolic comorbidities, and potential cancer recurrence.

  17. Do functional tests predict low back pain?

    PubMed

    Takala, E P; Viikari-Juntura, E

    2000-08-15

    A cohort of 307 nonsymptomatic workers and another cohort of 123 workers with previous episodes of low back pain were followed up for 2 years. The outcomes were measured by symptoms, medical consultations, and sick leaves due to low back disorders. To study the predictive value of a set of tests measuring the physical performance of the back in a working population. The hypothesis was that subjects with poor functional capacity are liable to back disorders. Reduced functional performance has been associated with back pain. There are few data to show whether reduced functional capacity is a cause or a consequence of pain. Mobility of the trunk in forward and side bending, maximal isokinetic trunk extension, flexion and lifting strength, and static endurance of back extension were measured. Standing balance and foot reaction time were recorded with a force plate. Clinical tests for the provocation of back or leg pain were performed. Gender, workload, age, and anthropometrics were managed as potential confounders in the analysis. Marked overlapping was seen in the measures of the subjects with different outcomes. Among the nonsymptomatic subjects, low performance in tests of mobility and standing balance was associated with future back disorders. Among workers with previous episodes of back pain, low isokinetic extension strength, poor standing balance, and positive clinical signs predicted future pain. Some associations were found between the functional tests and future low back pain. The wide variation in the results questions the value of the tests in health examinations (e.g., in screening or surveillance of low back disorders).

  18. Around Marshall

    NASA Image and Video Library

    1962-07-03

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow access tunnel which housed the cables for the controls. This construction photo taken July 3, 1962 depicts the Block House with a portion of its concrete walls poured and exposed while many are still in the forms stage.

  19. Locomotive syndrome is associated not only with physical capacity but also degree of depression.

    PubMed

    Ikemoto, Tatsunori; Inoue, Masayuki; Nakata, Masatoshi; Miyagawa, Hirofumi; Shimo, Kazuhiro; Wakabayashi, Toshiko; Arai, Young-Chang P; Ushida, Takahiro

    2016-05-01

    Reports of locomotive syndrome (LS) have recently been increasing. Although physical performance measures for LS have been well investigated to date, studies including psychiatric assessment are still scarce. Hence, the aim of this study was to investigate both physical and mental parameters in relation to presence and severity of LS using a 25-question geriatric locomotive function scale (GLFS-25) questionnaire. 150 elderly people aged over 60 years who were members of our physical-fitness center and displayed well-being were enrolled in this study. Firstly, using the previously determined GLFS-25 cutoff value (=16 points), subjects were divided into two groups accordingly: an LS and non-LS group in order to compare each parameter (age, grip strength, timed-up-and-go test (TUG), one-leg standing with eye open, back muscle and leg muscle strength, degree of depression and cognitive impairment) between the groups using the Mann-Whitney U-test followed by multiple logistic regression analysis. Secondly, a multiple linear regression was conducted to determine which variables showed the strongest correlation with severity of LS. We confirmed 110 people for non-LS (73%) and 40 people for LS using the GLFS-25 cutoff value. Comparative analysis between LS and non-LS revealed significant differences in parameters in age, grip strength, TUG, one-leg standing, back muscle strength and degree of depression (p < 0.006, after Bonferroni correction). Multiple logistic regression revealed that functional decline in grip strength, TUG and one-leg standing and degree of depression were significantly associated with LS. On the other hand, we observed that the significant contributors towards the GLFS-25 score were TUG and degree of depression in multiple linear regression analysis. The results indicate that LS is associated with not only the capacity of physical performance but also the degree of depression although most participants fell under the criteria of LS. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  20. Effects of semi-rigid arch-support orthotics: an investigation with potential ergonomic implications.

    PubMed

    Kelaher, D; Mirka, G A; Dudziak, K Q

    2000-10-01

    For many years, arch-support orthotics have been prescribed for individuals with discomfort and/or abnormal skeletal alignments in the structures of the lower extremity. Recently there has been an increased interest in promoting semi-rigid orthotics as an ergonomic aid for asymptomatic workers who must stand all day at their workplace. A laboratory study was performed to assess the biomechanical impact of prefabricated semi-rigid orthotics on asymptomatic individuals. Ten subjects wore semi-rigid arch-support orthotics (experimental condition) for two months and flexible polyurethane/Sorbothane shoe inserts (control condition) for two months. Throughout this 18-week testing period, the subjects returned to the lab to perform a battery of assessment tests at regularly scheduled intervals. These tests examined subject strength, standing posture, stability, fatigue effects, and body part discomfort. The results of this study showed no significant changes in the strength, posture, or stability as a function of insert type. The subjects reported a reduction in low-back discomfort along with an increase in foot discomfort during a fatiguing exertion task while wearing the semi-rigid orthotics as compared to the control condition.

  1. Around Marshall

    NASA Image and Video Library

    1963-09-25

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built to the northeast of the stand was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton flame deflector at the rate of 320,000 gallons per minute. This photograph, taken September 25, 1963, depicts the construction progress of the Pump House and massive round water tanks on the right.

  2. Around Marshall

    NASA Image and Video Library

    1961-09-29

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 29, 1961, shows the progress of the concrete walls for the stand’s foundation. Some of the walls have been poured and some of the concrete forms have been removed.

  3. Around Marshall

    NASA Image and Video Library

    1961-09-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 15, 1961, shows the installation of the reinforcing steel prior to the pouring of the concrete foundation walls.

  4. Around Marshall

    NASA Image and Video Library

    1961-09-22

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 22, 1961, shows the progress of the concrete walls for the stand’s foundation. Some of the walls have been poured and some of the concrete forms have been removed.

  5. Around Marshall

    NASA Image and Video Library

    1961-09-07

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the forms for the concrete foundation walls as of September 7, 1961.

  6. Around Marshall

    NASA Image and Video Library

    1962-03-31

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built directly east of the test stand was the Block House, which served as the control center for the test stand. The two were connected by a narrow tunnel which housed the cables for the controls. Again to the east, just south of the Block House, was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton water deflector at the rate of 320,000 gallons per minute. In this photo, taken March 20, 1962, construction of the Pump House area is well underway.

  7. Around Marshall

    NASA Image and Video Library

    1963-08-12

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In addition to the stand itself, related facilities were constructed during this time. Built to the east was a newly constructed Pump House. Its function was to provide water to the stand to prevent melting damage during testing. The water was sprayed through small holes in the stand’s 1900 ton flame deflector at the rate of 320,000 gallons per minute. In this photo, taken August 12, 1963, the S-IC stand has received some of its internal components. Directly in the center is the framework that houses the flame deflector. The F-1 test stand, designed and built to test a single F-1 engine, can be seen on the left side of the photo.

  8. A Comparison of the Effects of Short-Term Plyometric and Resistance Training on Lower Body Muscular Performance.

    PubMed

    Whitehead, Malcolm T; Scheett, Timothy P; McGuigan, Michael R; Auckland, N Z; Martin, Angel V

    2017-11-01

    The purpose of this study was to compare effects of short-term plyometric and resistance training on lower body muscular performance. A convenience sample of thirty males aged 21.3 ± 1.8 years, height 177.3 ± 9.4 cm, mass 80.0 ± 2.6 kg, body fat 16.1 ± 1.2 % participated in this investigation. Participants were grouped and participated in progressive plyometric (PLT) or resistance training (SRT) twice per week for eight consecutive weeks or a control (CNT) group that did not participate in any training. Performance tests were administered prior to and following the training period and included measures of high-speed muscular strength (standing long jump, vertical jump), low-speed muscular strength (one-repetition maximal back squat), running speed (20-meter sprint) and running agility (505 agility test agility test-Test). Analysis of variance followed by post hoc analyses was performed to determine significant differences between the groups. Significance set at p ≤ 0.05 for all analyses. Significant improvements were observed in the PLT group for standing long jump, vertical jump, and one-repetition maximal back squat compared to the CNT group, and for vertical jump as compared to the SRT group. Significant improvements were observed in the SRT group one-repetition maximal back squat compared to the CNT group. There were no differences observed between any of the groups for the 20-meter sprint or the 505 agility test following the training. These data indicate eight weeks of progressive plyometric training results in improvements in parameters of high and low-speed muscular strength with no appreciable change in speed or agility. Additionally, the improvement in low-speed muscular strength observed from 8-weeks of progressive plyometric training was comparable to the results observed from 8-weeks of progressive strength training.

  9. Relationship of Sit-to-Stand Lower-Body Power With Functional Fitness Measures Among Older Adults With and Without Sarcopenia.

    PubMed

    Glenn, Jordan M; Gray, Michelle; Binns, Ashley

    When evaluating health in older adults, batteries of tests are typically utilized to assess functional fitness. Unfortunately, physician's visits are time-sensitive, and it may be important to develop faster methods to assess functional fitness that can be utilized in professional or clinical settings. Therefore, the purpose of this investigation was to examine the relationship of sit-to-stand (STS) power generated through the STS task with previously established measures of functional fitness, specifically strength, endurance, speed, agility, and flexibility in older adults with and without sarcopenia. This study consisted of 57 community-dwelling older adults (n = 16 males; n = 41 females). Functional fitness was assessed using the Short Physical Performance Battery (SPPB), Senior Fitness Test, handgrip, gait speed (habitual and maximal), balance, and STS power generated via the Tendo Weightlifting Analyzer. On the basis of data distribution, second-degree polynomial (quadratic) curvilinear models (lines of best fit) were applied for the relationships of 5-time STS time with average and peak power. Zero-order correlations were evaluated between STS power and all other functional fitness measures. Older adults with sarcopenia were also identified (n = 15), and relationships were reevaluated within this subset. STS power (average and peak) was significantly (P ≤ .01) correlated with physical performance measured via previously established assessments. For average power, this was observed during the senior fitness test (6-minute walk [r = 0.39], 8-ft up-and-go [r = -0.46], arm curl [r = 0.46], and chair stand [r = 0.55]), SPPB (5-time STS time [r = -0.63] and 8-ft walk [r = -0.32]), and other independent functional fitness measures (grip strength [r = 0.65] and maximal gait speed [r = -0.31]). Similar results were observed for peak power during the senior fitness test (6-minute walk [r = 0.39], 8-ft up-and-go [r = -0.46], arm curl [r = 0.45], chair stand [r = 0.52], and sit-and-reach [r = -0.27]), SPPB (5-time STS time [r = -0.60] and 8-ft walk [r = -0.33]), and other independent functional fitness measures (grip strength [r = 0.70] and maximal gait speed [r = -0.32]). Within the sarcopenic subset, for average and peak power, respectively, significant relationships were still retained for handgrip strength (r = 0.57 and r = 0.57), 6-minute walk (r = 0.55 and r = 0.61), chair stand (r = 0.76 and r = 0.81), and 5-time STS time (r = -0.76 and r = -0.80) tests. STS power generated via the STS task significantly relates to commonly administered functional fitness measures. These relationships also appear to exist when evaluating these relationships in older adults with sarcopenia. STS power may be utilized as an independent measure of functional fitness that is feasible to incorporate in clinical settings where time and space are often limiting factors.

  10. Around Marshall

    NASA Image and Video Library

    1963-10-22

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the progress of the S-IC test stand as of October 22, 1963. Spherical liquid hydrogen tanks can be seen to the left. Just to the lower front of those are the cylindrical liquid oxygen (LOX) tanks.

  11. Around Marshall

    NASA Image and Video Library

    1961-06-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 13, 1961, progress is being made with the excavation of the S-IC test stand site. During the digging, a natural spring was disturbed which caused a constant flooding problem. Pumps were used to remove the water all through the construction process and the site is still pumped today.

  12. Around Marshall

    NASA Image and Video Library

    1963-03-29

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In the early stages of excavation, a natural spring was disturbed that caused a water problem which required constant pumping from the site and is even pumped to this day. Behind this reservoir of pumped water is the S-IC test stand boasting its ever-growing four towers as of March 29, 1963.

  13. Around Marshall

    NASA Image and Video Library

    1961-08-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photograph taken on August 5th, 1961, a back hoe is nearly submerged in water in the test stand site. During the initial digging, the disturbance of a natural spring contributed to constant water problems during the construction process. It was necessary to pump the water from the site on a daily basis and is still pumped from the site today.

  14. Around Marshall

    NASA Image and Video Library

    1961-08-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo shows the construction progress of the test stand as of August 14, 1961. Water gushing in from the disturbance of a natural spring contributed to constant water problems during the construction process. It was necessary to pump water from the site on a daily basis and is still pumped from the site today. The equipment is partially submerged in the water emerging from the spring.

  15. Construction Progress of the S-IC Test Stand-Pumps

    NASA Technical Reports Server (NTRS)

    1962-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken April 4, 1961, shows the S-IC test stand dry once again when workers resumed construction after a 6 month delay due to booster size reconfiguration back in September of 1961. The disturbance of a natural spring during the excavation of the site required water to be pumped from the site continuously. The site was completely flooded after the pumps were shut down during the construction delay.

  16. Around Marshall

    NASA Image and Video Library

    1961-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 5, 1961, shows the construction of forms which became the concrete foundation for the massive stand. The lower right hand corner reveals a pump used for extracting water emerging from a disturbed natural spring that occurred during excavation of the site. The pumping became a daily ritual and the site is still pumped today.

  17. Isometric muscle strength and mobility capacity in children with cerebral palsy.

    PubMed

    Dallmeijer, Annet J; Rameckers, Eugene A; Houdijk, Han; de Groot, Sonja; Scholtes, Vanessa A; Becher, Jules G

    2017-01-01

    To determine the relationship between isometric leg muscle strength and mobility capacity in children with cerebral palsy (CP) compared to typically developing (TD) peers. Participants were 62 children with CP (6-13 years), able to walk with (n = 10) or without (n = 52) walking aids, and 47 TD children. Isometric muscle strength of five muscle groups of the leg was measured using hand-held dynamometry. Mobility capacity was assessed with the 1-min walk, the 10-m walk, sit-to-stand, lateral-step-up and timed-stair tests. Isometric strength of children with CP was reduced to 36-82% of TD. When adjusted for age and height, the percentage of variance in mobility capacity that was explained by isometric strength of the leg muscles was 21-24% (walking speed), 25% (sit-to-stand), 28% (lateral-step-up) and 35% (timed-stair) in children with CP. Hip abductors and knee flexors had the largest contribution to the explained variance, while knee extensors showed the weakest correlation. Weak or no associations were found between strength and mobility capacity in TD children. Isometric strength, especially hip abductor and knee flexor strength, is moderately related to mobility capacity in children with CP, but not in TD children. To what extent training of these muscle groups will lead to better mobility capacity needs further study. Implications for Rehabilitation Strength training in children with cerebral palsy (CP) may be targeted more specifically at hip abductors and knee flexors. The moderate associations imply that large improvements in mobility capacity may not be expected when strength increases.

  18. Is one trial enough for repeated testing? Same-day assessments of walking, mobility and fine hand use in people with myotonic dystrophy type 1.

    PubMed

    Kierkegaard, Marie; Petitclerc, Emilie; Hébert, Luc J; Gagnon, Cynthia

    2017-02-01

    Performance-based assessments of physical function are essential in people with myotonic dystrophy type 1 (DM1) to monitor disease progression and evaluate interventions. Commonly used are the six-minute walk test, the 10 m-walk test, the timed up-and-go test, the timed-stands test, grip strength tests and the nine-hole peg test. The number of trials needed on a same-day test occasion and whether the first, best or average of trials should be reported as result is unknown. Thus, the aim was to describe and explore differences between trials in these measures of walking, mobility and fine hand use in 70 adults with DM1. Three trials were performed for each test except for the six-minute walk test where two trials were allowed. There were statistical significant differences over trials in all tests except for the 10 m-walk test and grip strength tests. Pair-wise comparisons showed that the second and third trials were in general better than the first, although effect sizes were small. At which trial the individuals performed their best differed between individuals and tests. People with severe muscular impairment had difficulties to perform repeated trials. Intraclass correlation coefficients were all high in analyses exploring how to report results. The conclusion and clinical implication is that, for a same-day test occasion, one trial is sufficient for the 10 m-walk test and grip strength tests, and that repeated trials should be allowed in the timed up-and-go test, timed-stands test and nine-hole peg tests. We recommend that two trials are performed for these latter tests as such a protocol could accommodate people with various levels of impairments and physical limitations. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Maintenance of exercise training benefits is associated with adequate milk and dairy products intake in elderly hypertensive subjects following detraining.

    PubMed

    Moraes, Wilson Max Almeida Monteiro de; Santos, Neucilane Silveira Dos; Aguiar, Larissa Pereira; Sousa, Luís Gustavo Oliveira de

    2017-01-01

    To investigate whether maintenance of exercise training benefits is associated with adequate milk and dairy products intake in hypertensive elderly subjects after detraining. Twenty-eight elderly hypertensive patients with optimal clinical treatment underwent 16 weeks of multicomponent exercise training program followed by 6 weeks of detraining, and were classified according to milk and dairy products intake as low milk (<3 servings) and high milk (≥3 servings) groups. After exercise training, there was a significant reduction (p<0.001) in body weight, systolic, diastolic and mean blood pressure, an increase in lower and upper limb strength (chair-stand test and elbow flexor test) as well as in aerobic capacity (stationary gait test) and functional capacity (sit down, stand up, and move around the house) in both groups. However, in the Low Milk Intake Group significant changes were observed: body weight (+0.5%), systolic, diastolic and mean blood pressure (+0.9%,+1.4% and +1.1%, respectively), lower extremity strength (-7.0%), aerobic capacity (-3.9%) and functional capacity (+5.4) after detraining. These parameters showed no significant differences between post-detraining and post-training period in High Milk Intake Group. Maintenance of exercise training benefits related to pressure levels, lower extremity strength and aerobic capacity, is associated with adequate milk and dairy products intake in hypertensive elderly subjects following 6 weeks of detraining.

  20. How fit are children and adolescents with haemophilia in Germany? Results of a prospective study assessing the sport-specific motor performance by means of modern test procedures of sports science.

    PubMed

    Seuser, A; Boehm, P; Ochs, S; Trunz-Carlisi, E; Halimeh, S; Klamroth, R

    2015-07-01

    There are a lot of publications on the physical fitness of patients with haemophilia (PWH), however, most studies only reflect individual sport-specific motor capacities or focus on a single fitness ability. They involve small patient populations. In this respect principal objective of this study was to compare the physical fitness in all respects and the body composition of young PWH to healthy peers based on the most valid data we could get. Twenty-one German haemophilia treatment centres were visited from 2002 to 2009. PWH between 8 and 25 years were included. They performed a five-stage fitness test covering the sport-specific motor capacities for coordination, measured by one leg stand, strength, aerobic fitness and mobility as well as body composition. The patients' results were compared with age- and gender-specific reference values of healthy subjects. Two hundred and eighty-five PWH (mean age 13.2 ± 4.5 years, 164 PWH with severe disease) were included prospectively in the study. PWH are significantly below the reference values of healthy subjects in the one-leg stand test, the mobility of the lower extremity, the strength ratio of chest and back muscles and the endurance test. In body composition, the back strength and the mobility of the upper extremity PWH are significantly above the reference values. There are no significant differences in abdominal strength. In conclusion we found specific differences in different fitness abilities between PWH and healthy subjects. Knowing this, we are able to work out exercise programmes to compensate the diminished fitness abilities for our PWH. © 2015 John Wiley & Sons Ltd.

  1. Effect of isokinetic training on strength, functionality and proprioception in athletes with functional ankle instability.

    PubMed

    Sekir, Ufuk; Yildiz, Yavuz; Hazneci, Bulent; Ors, Fatih; Aydin, Taner

    2007-05-01

    The purpose of this study was to investigate the effects of isokinetic exercise on strength, joint position sense and functionality in recreational athletes with functional ankle instability (FAI). Strength, proprioception and balance of 24 recreational athletes with unilateral FAI were evaluated by using isokinetic muscle strength measurement, ankle joint position sense and one leg standing test. The functional ability was evaluated using five different tests. These were; single limb hopping course (SLHC), one legged and triple legged hop for distance (OLHD-TLHD), and six and cross six meter hop for time (SMHT-CSMHT). Isokinetic peak torque of the ankle invertor and evertor muscles were assessed eccentrically and concentrically at test speeds of 120 degrees /s. Isokinetic exercise protocol was carried out at an angular velocity of 120 degrees /s. The exercise session was repeated three times a week and lasted after 6 weeks. At baseline, concentric invertor strength was found to be significantly lower in the functionally unstable ankles compared to the opposite healthy ankles (p < 0.001). This difference was not present after executing the 6 weeks exercise sessions (p > 0.05). Ankle joint position sense in the injured ankles declined significantly from 2.35 +/- 1.16 to 1.33 +/- 0.62 degrees for 10 degrees of inversion angle (p < 0.001) and from 3.10 +/- 2.16 to 2.19 +/- 0.98 degrees for 20 degrees of inversion angle (p < 0.05) following the isokinetic exercise. One leg standing test score decreased significantly from 15.17 +/- 8.50 to 11.79 +/- 7.81 in the injured ankles (p < 0.001). Following the isokinetic exercise protocol, all of the worsened functional test scores in the injured ankles as compared to the opposite healthy ankles displayed a significant improvement (p < 0.01 for OLHD and CSMHT, p < 0.001 for SLHC, TLHD, and SMHT). These results substantiate the deficits of strength, proprioception, balance and functionality in recreational athletes with FAI. The isokinetic exercise program used in this study had a positive effect on these parameters.

  2. Around Marshall

    NASA Image and Video Library

    1962-03-31

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September 1961 as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction about to resume, portable, floating pump stations were placed in the site to drain the flood waters caused by a disturbed natural spring months prior during excavation. In this March 31, 1962 photo, the foundation walls can once again be seen.

  3. Around Marshall

    NASA Image and Video Library

    1961-12-22

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 22, 1961, shows danger signs posted around the abandoned site with floods nearing the top. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  4. Around Marshall

    NASA Image and Video Library

    1962-03-15

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken March 15, 1962, shows danger signs posted around the abandoned, flooded site. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  5. Around Marshall

    NASA Image and Video Library

    1962-03-20

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction about to resume, portable floating pump stations were placed in the site, as seen in this March 20, 1962 photo, to drain the flood waters caused by a disturbed natural spring months prior during excavation.

  6. Around Marshall

    NASA Image and Video Library

    1961-12-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 4, 1961, shows the abandoned site with floods at the 11 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  7. Around Marshall

    NASA Image and Video Library

    1961-12-18

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 18, 1961, shows the abandoned site entirely flooded. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  8. Around Marshall

    NASA Image and Video Library

    1961-12-11

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 11, 1961, shows the abandoned site with floods above the 18 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  9. Around Marshall

    NASA Image and Video Library

    1961-12-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 1, 1961, shows the abandoned site with floods at the 6 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  10. n/a

    NASA Image and Video Library

    1961-12-11

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 11, 1961, shows the abandoned site with floods above the 18 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  11. Around Marshall

    NASA Image and Video Library

    1961-12-08

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 8, 1961, shows the abandoned site with floods at the 16 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  12. Around Marshall

    NASA Image and Video Library

    1961-12-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand would have to be modified. With construction delayed, and pumps turned off, this photo, taken December 4, 1961, shows the abandoned site with floods at the 11 ft mark. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  13. Around Marshall

    NASA Image and Video Library

    1961-12-14

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken December 14, 1961, shows the abandoned site entirely flooded. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  14. Around Marshall

    NASA Image and Video Library

    1962-02-02

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. Construction of the S-IC test stand came to a halt at the end of September as the determination was made that the Saturn booster size had to be increased. As a result, the stand had to be modified. With construction delayed, and pumps turned off, this photo, taken February 2, 1962, shows the abandoned flooded site. The flooding was caused by the disturbance of a natural spring months prior during the excavation of the site.

  15. Early reduction in toe flexor strength is associated with physical activity in elderly men.

    PubMed

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi

    2016-05-01

    [Purpose] To compare the toe flexor, hand grip and knee extensor strengths of young and elderly men, and to examine the association between toe flexor strength and physical activity or inactivity levels. [Subjects and Methods] Young (n=155, 18-23 years) and elderly (n=60, 65-88 years) men participated in this study. Toe flexor, hand grip, and knee extensor strength were measured. Physical activity (time spent standing/walking per day) and inactivity (time spent sitting per day) were assessed using a self-administered questionnaire. [Results] Toe flexor, hand grip, and knee extensor strength of the elderly men were significantly lower than those of the young men. Standing/walking and sitting times of the elderly men were lower than those of the young men. Toe flexor strength correlated with hand grip and knee extensor strength in both groups. In elderly men, toe flexor strength correlated with standing/walking time. In comparison to the young men's mean values, toe flexor strength was significantly lower than knee extensor and hand grip strength in the elderly group. [Conclusion] The results suggest that age-related reduction in toe flexor strength is greater than those of hand grip and knee extensor strengths. An early loss of toe flexor strength is likely associated with reduced physical activity in elderly men.

  16. Back muscle strength, lifting, and stooped working postures.

    PubMed

    Poulsen, E; Jørgensen, K

    1971-09-01

    When lifting loads and working in a forward stooped position, the muscles of the back rather than the ligaments and bony structures of the spine should overcome the gravitational forces. Formulae, based on measurements of back muscle strength, for prediction of maximal loads to be lifted, and for the ability to sustain work in a stooped position, have been worked out and tested in practical situations. From tests with 50 male and female subjects the simplest prediction formulae for maximum loads were: max. load = 1.10 x isometric back muscle strength for men; and max. load = 0.95 x isometric back muscle strength - 8 kg for women. Some standard values for maximum lifts and permissible single and repeated lifts have been calculated for men and women separately and are given in Table 1. From tests with 65 rehabilitees it was found that the maximum isometric strength of the back muscles measured at shoulder height should exceed 2/3 of the body weight, if fatigue and/or pain in the back muscles is to be avoided during work in a standing stooped position.

  17. Dynamic balance ability in young elite soccer players: implication of isometric strength.

    PubMed

    Chtara, Moktar; Rouissi, Mehdi; Bragazzi, Nicola L; Owen, Adam L; Haddad, Monoem; Chamari, Karim

    2018-04-01

    Soccer requires maintaining unilateral balance when executing movement with the contralateral leg. Despite the fact that balance requires standing with maintaining isometric posture with the support leg, currently there is a lack of studies regarding the implication of isometric strength on dynamic balance's performance among young soccer players. Therefore, the aim of this study was to examine the relationship between the Y-Balance Test and 12 lower limbs isometric strength tests. Twenty-six right footed soccer players (mean±SD, age=16.2±1.6 years, height=175±4.2 cm, body mass=68.8±6.1 kg) performed a dynamic balance test (star excursion balance-test with dominant- (DL) and nondominant-legs (NDL). Furthermore, maximal isometric contraction tests of 12 lower limb muscle groups were assessed in DL and NDL. Correlations analysis reported a significant positive relationship between some of isometric strength tests (with DL and NDL) and the Y-Balance Test. Furthermore, stepwise multiple regression analysis showed that maximal isometric strength explained between 21.9% and 49.4% of the variance of the Y-Balance Test. Moreover, maximal isometric strength was dependent upon the reaching angle of the Y-Balance Test and the leg used to support body weight. This study showed a significant implication of maximal isometric strength of the lower limb and the Y-Balance Test. Moreover, the present investigation suggests the implementation of specific lower limb strengthening exercises depending on players' deficit in each reaching direction and leg. This result suggests that further studies should experiment if increasing lower limbs isometric strength could improve dynamic balance ability among young soccer players.

  18. Construct validity of functional capacity tests in healthy workers

    PubMed Central

    2013-01-01

    Background Functional Capacity (FC) is a multidimensional construct within the activity domain of the International Classification of Functioning, Disability and Health framework (ICF). Functional capacity evaluations (FCEs) are assessments of work-related FC. The extent to which these work-related FC tests are associated to bio-, psycho-, or social factors is unknown. The aims of this study were to test relationships between FC tests and other ICF factors in a sample of healthy workers, and to determine the amount of statistical variance in FC tests that can be explained by these factors. Methods A cross sectional study. The sample was comprised of 403 healthy workers who completed material handling FC tests (lifting low, overhead lifting, and carrying) and static work FC tests (overhead working and standing forward bend). The explainable variables were; six muscle strength tests; aerobic capacity test; and questionnaires regarding personal factors (age, gender, body height, body weight, and education), psychological factors (mental health, vitality, and general health perceptions), and social factors (perception of work, physical workloads, sport-, leisure time-, and work-index). A priori construct validity hypotheses were formulated and analyzed by means of correlation coefficients and regression analyses. Results Moderate correlations were detected between material handling FC tests and muscle strength, gender, body weight, and body height. As for static work FC tests; overhead working correlated fair with aerobic capacity and handgrip strength, and low with the sport-index and perception of work. For standing forward bend FC test, all hypotheses were rejected. The regression model revealed that 61% to 62% of material handling FC tests were explained by physical factors. Five to 15% of static work FC tests were explained by physical and social factors. Conclusions The current study revealed that, in a sample of healthy workers, material handling FC tests were related to physical factors but not to the psychosocial factors measured in this study. The construct of static work FC tests remained largely unexplained. PMID:23758870

  19. Saturn Apollo Program

    NASA Image and Video Library

    1965-04-16

    This photograph depicts a dramatic view of the first test firing of all five F-1 engines for the Saturn V S-IC stage at the Marshall Space Flight Center. The testing lasted a full duration of 6.5 seconds. It also marked the first test performed in the new S-IC static test stand and the first test using the new control blockhouse. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. Required to hold down the brute force of a 7,500,000-pound thrust, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900 ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minute.

  20. Pain and functional capacity in female fibromyalgia patients.

    PubMed

    Carbonell-Baeza, Ana; Aparicio, Virginia A; Sjöström, Michael; Ruiz, Jonatan R; Delgado-Fernández, Manuel

    2011-11-01

    To examine the association between pain and functional capacity levels. [corrected] Cross-sectional study. University of Granada. One hundred twenty-three women with fibromyalgia (51.7 ± 7.2 years). We measured weight and height, and body mass index (BMI) was calculated. We assessed tender points by pressure pain and functional capacity by means of the 30-second chair stand, handgrip strength, chair sit and reach, back scratch, blind flamingo, 8-ft up and go and 6-minute walk tests. We observed an association of tender points count with the chair stand and 6-minute walk tests (r = -0.273, P = 0.004 and r = -0.183, P = 0.046, respectively). These associations became nonsignificant once the analyses were adjusted by weight or BMI. We observed an association of algometer score with the back scratch, chair stand, and 6-minute walk tests (r = 0.238, P = 0.009; r = 0.363, P < 0.001; and r = 0.186, P = 0.043, respectively), which remained after adjusting for weight or BMI, except the association between algometer score and the 6-minute walk test that became nonsignificant once the analyses were adjusted by weight. Prevalence of overweight and obesity was 39.2 and 33.3%, respectively. There is an inverse association of tender points count with the chair stand and distance walked in the 6-minute walk tests, and a positive association of algometer score with the chair stand, distance walked in the 6-minute walk and back scratch tests, yet, weight status seems to play a role in these associations. Wiley Periodicals, Inc.

  1. Validity and reliability of an iPhone App to assess time, velocity and leg power during a sit-to-stand functional performance test.

    PubMed

    Ruiz-Cárdenas, Juan Diego; Rodríguez-Juan, Juan José; Smart, Rowan R; Jakobi, Jennifer M; Jones, Gareth R

    2018-01-01

    The purposes of this study were: (i) Analyze the concurrent validity and reliability of an iPhone App for measuring time, velocity and power during a single sit-to-stand (STS) test compared with measurements recorded from a force plate; and (ii) Evaluate the relationship between the iPhone App measures with age and functional performance. Forty-eight healthy individuals (age range: 26-81 years) were recruited. All participants completed a STS test on a force plate with the movement recorded on an iPhone 6 at 240 frames-per-second. Functional ability was also measured using isometric handgrip strength and self-paced walking time tests. Intraclass correlation coefficients (ICC), Pearson's correlation coefficient, Cronbach's alpha (α) and Bland-Altman plots with 95% confidence intervals (CI) were used to test validity and reliability between instruments. The results showed a good agreement between all STS measurement variables; time (ICC=0.864, 95%CI=0.77-0.92; α=0.926), velocity (ICC=0.912, 95%CI=0.85-0.95; α=0.953) and power (ICC=0.846, 95%CI=0.74-0.91; α=0.917) with no systematic bias between instruments for any variable analyzed. STS time, velocity and power derived from the iPhone App show moderate to strong associations with age (|r|=0.63-0.83) and handgrip strength (|r|=0.4-0.64) but not the walking test. The results of this study identify that this iPhone App is reliable for measuring STS and the derived values of time, velocity and power shows strong associations with age and handgrip strength. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Early reduction in toe flexor strength is associated with physical activity in elderly men

    PubMed Central

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi

    2016-01-01

    [Purpose] To compare the toe flexor, hand grip and knee extensor strengths of young and elderly men, and to examine the association between toe flexor strength and physical activity or inactivity levels. [Subjects and Methods] Young (n=155, 18–23 years) and elderly (n=60, 65–88 years) men participated in this study. Toe flexor, hand grip, and knee extensor strength were measured. Physical activity (time spent standing/walking per day) and inactivity (time spent sitting per day) were assessed using a self-administered questionnaire. [Results] Toe flexor, hand grip, and knee extensor strength of the elderly men were significantly lower than those of the young men. Standing/walking and sitting times of the elderly men were lower than those of the young men. Toe flexor strength correlated with hand grip and knee extensor strength in both groups. In elderly men, toe flexor strength correlated with standing/walking time. In comparison to the young men’s mean values, toe flexor strength was significantly lower than knee extensor and hand grip strength in the elderly group. [Conclusion] The results suggest that age-related reduction in toe flexor strength is greater than those of hand grip and knee extensor strengths. An early loss of toe flexor strength is likely associated with reduced physical activity in elderly men. PMID:27313353

  3. A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Evans, Kurt B.; Schiffman, Robert L.; Deweese, C. Darrell; Prince, Michael E.

    1995-01-01

    Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

  4. Normal Bone Microstructure and Density But Worse Physical Function in Older Women Treated with Selective Serotonin Reuptake Inhibitors, a Cross-Sectional Population-Based Study.

    PubMed

    Larsson, Berit; Mellström, Dan; Johansson, Lisa; Nilsson, Anna G; Lorentzon, Mattias; Sundh, Daniel

    2018-05-05

    Depression in the elderly is today often treated with selective serotonin reuptake inhibitors (SSRIs) because of their favorable adverse effect profile. However, treatment with SSRIs is associated with increased risk of fractures. Whether this increased risk depends on reduced bone strength or increased fall risk due to reduced physical function is not certain. The aim was therefore to investigate if treatment with SSRIs is associated with impaired bone microstructure, bone density, or physical function in older women. From an ongoing population-based study, 1057 women (77.7 ± 1.5 years) were included. Validated questionnaires were used to assess information regarding medical history, medications, smoking, mental and physical health, and physical activity. Physical function was measured using clinically used tests: timed up and go, walking speed, grip strength, chair stand test, and one leg standing. Bone mineral density (BMD) was measured at the hip and spine with dual-energy X-ray absorptiometry (Hologic Discovery A). Bone geometry and microstructure were measured at the ultradistal and distal (14%) site of radius and tibia using high-resolution peripheral quantitative computed tomography (HR-pQCT; XtremeCT). Treatment with SSRIs was associated with higher BMD at the femoral neck, total hip, and lumbar spine, whereas no associations were found for any HR-pQCT-derived measurements. The use of SSRIs was associated with lower grip strength, walking speed, and fewer chair stand rises. These associations were valid also after adjustments for known risk factors for falls. Treatment with SSRIs was, independently of covariates, associated with worse physical function without any signs of inferior bone geometry and microstructure.

  5. Around Marshall

    NASA Image and Video Library

    1962-04-16

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. After a 6 month delay in construction due to size reconfiguration of the Saturn booster, the site was revisited for modifications. The original foundation walls built in the prior year had to be torn down and re-poured to accommodate the larger booster. The demolition can be seen in this photograph taken on April 16, 1962.

  6. Around Marshall

    NASA Image and Video Library

    1962-06-13

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. After a six month delay in construction due to size reconfiguration of the Saturn booster, the site was revisited for modifications in March 1962. The original foundation walls built in the prior year were torn down and re-poured to accommodate the larger boosters. This photo depicts that modification progress as of June 13,1962.

  7. Around Marshall

    NASA Image and Video Library

    1962-05-21

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. After a 6 month delay in construction due to size reconfiguration of the Saturn booster, the site was revisited for modifications. The original foundation walls built in the prior year had to be torn down and re-poured to accommodate the larger booster. The demolition can be seen in this photograph taken on May 21, 1962.

  8. Around Marshall

    NASA Image and Video Library

    1961-09-05

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken September 5, 1961, shows pumps used for extracting water emerging form a disturbed natural spring that occurred during the excavation of the site. The pumping became a daily ritual and the site is still pumped today.

  9. Around Marshall

    NASA Image and Video Library

    1962-04-04

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army’s Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photo, taken April 4, 1961, shows the S-IC test stand dry once again when workers resumed construction after a 6 month delay due to booster size reconfiguration back in September of 1961. The disturbance of a natural spring during the excavation of the site required water to be pumped from the site continuously. The site was completely flooded after the pumps were shut down during the construction delay.

  10. Low-noise, high-strength, spiral-bevel gears for helicopter transmissions

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.; Handschuh, Robert F.; Henry, Zachary S.; Litvin, Faydor L.

    1993-01-01

    Improvements in spiral-bevel gear design were investigated to support the Army/NASA Advanced Rotorcraft Transmission program. Program objectives were to reduce weight by 25 percent, reduce noise by 10 dB, and increase life to 5000 hr mean-time-between-removal. To help meet these goals, advanced-design spiral-bevel gears were tested in an OH-58D helicopter transmission using the NASA 500-hp Helicopter Transmission Test Stand. Three different gear designs tested included: (1) the current design of the OH-58D transmission except gear material X-53 instead of AISI 9310; (2) a higher-strength design the same as the current but with a full fillet radius to reduce gear tooth bending stress (and thus, weight); and (3) a lower-noise design the same as the high-strength but with modified tooth geometry to reduce transmission error and noise. Noise, vibration, and tooth strain tests were performed and significant gear stress and noise reductions were achieved.

  11. Effect of whole-body vibration exercise on mobility, balance ability and general health status in frail elderly patients: a pilot randomized controlled trial.

    PubMed

    Zhang, Li; Weng, Changshui; Liu, Miao; Wang, Qiuhua; Liu, Liming; He, Yao

    2014-01-01

    To study the effects of whole-body vibration exercises on the mobility function, balance and general health status, and its feasibility as an intervention in frail elderly patients. Pilot randomized controlled trial. Forty-four frail older persons (85.27 ± 3.63 years) meeting the Fried Frailty Criteria. All eligible subjects were randomly assigned to the experimental group, who received a whole-body vibration exercise alone (vibration amplitude: 1-3 mm; frequency: 6-26 Hz; 4-5 bouts × 60 seconds; 3-5 times weekly), or a control group, who received usual care and exercises for eight weeks. The Timed Up and Go Test, 30-second chair stand test, lower extremities muscle strength, balance function, balance confidence and General Health Status were assessed at the beginning of the study, after four weeks and eight weeks of the intervention. Whole-body vibration exercise reduced the time of the Timed Up and Go Test (40.47 ± 15.94 s to 21.34 ± 4.42 s), improved the bilateral knees extensor strength (6.96 ± 1.70 kg to 11.26 ± 2.08 kg), the posture stability (surface area ellipse: 404.58 ± 177.05 to 255.95 ± 107.28) and General Health Status (Short-form Health Survey score: 24.51 ± 10.69 and 49.63 ± 9.85 to 45.03 ± 11.15 and 65.23 ± 9.39, respectively). The repeated-measures ANOVA showed that there were significant differences in the Timed Up and Go Test, 30-second chair stand test, bilateral knees extensor strength, activities-specific balance confidence score and general health status between the two groups (P < 0.05). No side-effects were observed during the training. Whole-body vibration exercise is a safe and effective method that can improve the mobility, knee extensor strength, balance and the general health status in the frail elderly.

  12. Effect of a Mat Pilates Program with TheraBand on Dynamic Balance in Patients with Parkinson's Disease: Feasibility Study and Randomized Controlled Trial.

    PubMed

    Mollinedo-Cardalda, Irimia; Cancela-Carral, José María; Vila-Suárez, María Helena

    2018-01-24

    The aim of this study was to assess the effect of a physical exercise program based on Mat Pilates (MP) with TheraBand ® on the dynamic balance of a sample population diagnosed with Parkinson's disease (PD). After random selection, 26 participants were allocated to a MP group or a control group where they performed calisthenics exercises. Both interventions lasted 12 weeks and involved 2 weekly sessions of 60 minutes. Assessments took place at baseline, 12 weeks after the intervention started and 4 weeks after the intervention was completed using the body mass index (BMI), the Timed Up and Go (TUG) test with Wiva ® sensors, the 30 Second Chair Stand test, and the Five Times Sit to Stand test. The group that completed the MP program presented significant improvements in BMI (F 1,21  = 3.986; p = 0.038), the 30 Second Chair Stand test (F 1,21  = 6.716; p = 0.014), the Five Times Sit to Stand test (F 1,21  = 5.213; p = 0.032), and the time required to complete the TUG dynamic balance test (F 1,21  = 5.035; p = 0.035). The MP program performed by a sample population with PD led to improvements in dynamic balance, and participants in the MP group showed increased strength in the lower limbs, but such improvements were not permanent after the activity ceased.

  13. Exercise training program based on minimum weekly frequencies: effects on blood pressure and physical fitness in elderly hypertensive patients.

    PubMed

    Moraes, Wilson M De; Souza, Pamella R M; Pinheiro, Mônica H N P; Irigoyen, Maria C; Medeiros, Alessandra; Koike, Marcia K

    2012-04-01

    Exercise training (ET) can reduce blood pressure (BP) and prevent functional disability. However, the effects of low volumes of training have been poorly studied, especially in elderly hypertensive patients. To investigate the effects of a multi-component ET program (aerobic training, strength, flexibility, and balance) on BP, physical fitness, and functional ability of elderly hypertensive patients. Thirty-six elderly hypertensive patients with optimal clinical treatment underwent a multi-component ET program: two 60-minute sessions a week for 12 weeks at a Basic Health Unit. Compared to pre-training values, systolic and diastolic BP were reduced by 3.6% and 1.2%, respectively (p<0.001), body mass index was reduced by 1.1% (p<0.001), and peripheral blood glucose was reduced by 2.5% (p=0.002). There were improvements in all physical fitness domains: muscle strength (chair-stand test and elbow flexor test; p<0.001), static balance test (unipedal stance test; p<0.029), aerobic capacity (stationary gait test; p<0.001), except for flexibility (sit and reach test). Moreover, there was a reduction in the time required to perform two functional ability tests: "put on sock" and "sit down, stand up, and move around the house" (p<0.001). Lower volumes of ET improved BP, metabolic parameters, and physical fitness and reflected in the functional ability of elderly hypertensive patients. Trial Registration RBR-2xgjh3.

  14. Association of plasma 25-hydroxyvitamin D with physical performance in physically active children.

    PubMed

    Bezrati, Ikram; Hammami, Raouf; Ben Fradj, Mohamed Kacem; Martone, Domenico; Padulo, Johnny; Feki, Moncef; Chaouachi, Anis; Kaabachi, Naziha

    2016-11-01

    Vitamin D is thought to regulate skeletal muscle function and boost physical performance. The aim of this study was to assess the relationship between vitamin D and physical performance in physically active children. This cross-sectional study included 125 children who practice football as a leisure activity. Plasma 25-hydroxyvitamin D (25-OHD) was assessed using a chemiluminescence immunoassay method. Vitamin D inadequacy was defined as 25-OHD < 20 ng/mL. Physical performance testing included measurements of muscle strength (maximal isometric contraction), jumping ability (vertical jump, standing broad jump, triple hop test), linear sprint (10 m and 20 m), and agility (9 × 4-m shuttle run). Plasma 25-OHD concentrations were positively correlated with muscle strength (r = 0.539; p < 0.001), vertical jump (r = 0.528; p < 0.001), and standing broad jump (r = 0.492; p < 0.001) but inversely correlated with sprint performance (r = -0.539; p < 0.001). In multivariate analysis models, plasma 25-OHD concentrations were associated with each physical performance parameter independently of age, maturity status, body mass index, fat mass, and protein and calcium intakes. In conclusion, a low plasma 25-OHD level was associated with decreased muscle strength, agility, and jumping and sprinting abilities in physically active children. Vitamin D inadequacy may limit exercise performance. Further research should verify whether correction of vitamin D deficiency enhances physical performance.

  15. Impact of visual and somatosensory deprivation on dynamic balance in adolescent idiopathic scoliosis.

    PubMed

    Kuo, Fang-Chuan; Wang, Nai-Hwei; Hong, Chang-Zern

    2010-11-01

    A cross-sectional study of balance control in adolescents with idiopathic scoliosis (AIS). To investigate the impact of visual and somatosensory deprivation on the dynamic balance in AIS patients and to discuss electromyographic (EMG) and posture sway findings. Most studies focus on posture sway in quiet standing controls with little effort on examining muscle-activated patterns in dynamic standing controls. Twenty-two AIS patients and 22 age-matched normal subjects were studied. To understand how visual and somatosensory information could modulate standing balance, balance tests with the Biodex stability system were performed on a moving platform under 3 conditions: visual feedback provided (VF), eyes closed (EC), and standing on a sponge pad with visual feedback provided (SV). Muscular activities of bilateral lumbar multifidi, gluteus medii, and gastrocnemii muscles were recorded with a telemetry EMG system. AIS patients had normal balance index and amplitude and duration of EMG similar to those of normal subjects in the balance test. However, the onset latency of right gastrocnemius was earlier in AIS patients than in normal subjects. In addition, body-side asymmetry was noted on muscle strength and onset latency in AIS subjects. Under EC condition, lumbar multifidi, and gluteus medii activities were higher than those under SV and VF conditions (P < 0.05). Under SV condition, the medial-lateral tilting angle was less than that under VF and EC conditions. In addition, the active duration of right gluteus medius was shorter under SV condition (P < 0.05). The dynamic balance control is particularly disruptive under visual deprivation with increasing lumbar multifidi and gluteus medii activities for compensation. Sponge pad can cause decrease in frontal plane tilting and gluteus medii effort. The asymmetric muscle strength and onset timing are attributed to anatomic deformation as opposed to neurologic etiological factors.

  16. Postural strategy and trunk muscle activation during prolonged standing in chronic low back pain patients.

    PubMed

    Ringheim, Inge; Austein, Helene; Indahl, Aage; Roeleveld, Karin

    2015-10-01

    Prolonged standing has been associated with development and aggravation of low back pain (LBP). However, the underlying mechanisms are not well known. The aim of the present study was to investigate postural control and muscle activation during and as a result of prolonged standing in chronic LBP (cLBP) patients compared to healthy controls (HCs). Body weight shifts and trunk and hip muscle activity was measured during 15 min standing. Prior and after the standing trial, strength, postural sway, reposition error (RE), flexion relaxation ratio (FRR), and pain were assessed and after the prolonged standing, ratings of perceived exertion. During prolonged standing, the cLBP patients performed significantly more body weight shifts (p<.01) with more activated back and abdominal muscles (p=.01) and similar temporal variability in muscle activation compared to HCs, while the cLBP patients reported more pain and perceived exertion at the end of prolonged standing. Moreover, both groups had a similar change in strength, postural sway, RE and FRR from before to after prolonged standing, where changes in HC were towards pre-standing values of cLBP patients. Thus, despite a more variable postural strategy, the cLBP patients did not have higher muscle activation variability, but a general increased muscle activation level. This may indicate a reduced ability to individually deactivate trunk muscles. Plausibly, due to the increased variable postural strategy, the cLBP patients could compensate for the relatively high muscle activation level, resulting in normal variation in muscle activation and normal reduction in strength, RE and FRR after prolonged standing. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Associations Between Balance and Muscle Strength, Power Performance in Male Youth Athletes of Different Maturity Status.

    PubMed

    Hammami, Raouf; Chaouachi, Anis; Makhlouf, Issam; Granacher, Urs; Behm, David G

    2016-11-01

    Balance, strength and power relationships may contain important information at various maturational stages to determine training priorities. The objective was to examine maturity-specific relationships of static/dynamic balance with strength and power measures in young male athletes. Soccer players (N = 130) aged 10-16 were assessed with the Stork and Y balance (YBT) tests. Strength/power measures included back extensor muscle strength, standing long jump (SLJ), countermovement jump (CMJ), and 3-hop jump tests. Associations between balance with strength/power variables were calculated according to peak-height-velocity (PHV). There were significant medium-large sized correlations between all balance measures with back extensor strength (r = .486-.791) and large associations with power (r = .511-.827). These correlation coefficients were significantly different between pre-PHV and circa PHV as well as pre-PHV and post-PHV with larger associations in the more mature groups. Irrespective of maturity-status, SLJ was the best strength/power predictor with the highest proportion of variance (12-47%) for balance (i.e., Stork eyes opened) and the YBT was the best balance predictor with the highest proportion of variance (43-78%) for all strength/power variables. The associations between balance and muscle strength/power measures in youth athletes that increase with maturity may imply transfer effects from balance to strength/power training and vice versa in youth athletes.

  18. Sexual health in patients with rheumatoid arthritis and the association between physical fitness and sexual function: a cross-sectional study.

    PubMed

    Dorner, Thomas Ernst; Berner, Carolin; Haider, Sandra; Grabovac, Igor; Lamprecht, Thomas; Fenzl, Karl Heinrich; Erlacher, Ludwig

    2018-06-01

    The aim of this study was to examine sexual health in patients with rheumatoid arthritis (RA), and to analyse factors associated with sexual health with a focus on physical fitness. One hundred RA patients aged between 18 and 65 years were included in a cross-sectional study. Handgrip strength and knee extensor strength were measured with a dynamometer, and physical performance with the Short Physical Performance Battery (SPPB). Fifty-four patients, mean age 47.8 (SD 10.6) years, 61% female, answered a questionnaire about sexual health. Fifty-seven percent reported, at least, sometimes having difficulty with sexual intercourse (27.8% due to joint stiffness, 24.1% due to fatigue, 18.5% due to pain). Handgrip strength and knee extensor strength significantly correlated with the desire to engage in sexual intercourse, frequency of sexual contact and satisfaction with overall sex life. The SPPB total score correlated with satisfaction with overall sex life, and the SPPB repeated chair stands test with the desire to have sexual intercourse and satisfaction with overall sex life. After adjusting for age, gender, disease activity, comorbidity, co-medication and pain intensity, the repeated chair stands test remained significantly associated with the frequency of sexual contact (0.53; 0.01-1.05) and with satisfaction with overall sex life (1.39; 0.28-2.51). The results of this study show that problems with sexual health are highly prevalent in patients with RA. The ability to rise from a chair is associated with sexual function, independent of disease activity and pain intensity.

  19. Effect of an eccentrically biased hamstring strengthening home program on knee flexor strength and the length-tension relationship.

    PubMed

    Orishimo, Karl F; McHugh, Malachy P

    2015-03-01

    The purposes of this study were to document relative activation intensities of the hamstrings and gluteus maximus during 4 eccentric hamstring strengthening exercises and to assess the effects of a short-term strengthening program comprised of these exercises on knee flexor strength and the length-tension relationship. Twelve healthy subjects participated in this study. Electromyographic (EMG) activities from the biceps femoris, semitendinosus, and gluteus maximus were recorded as subjects performed (a) standing hip extension with elastic resistance, (b) trunk flexion in single limb stance (diver), (c) standing split (glider), and (d) supine sliding bridge (slider). Baseline isometric knee flexor strength was measured at 90, 70, 50, and 30° of flexion at the knee with the subject seated and the hip flexed to 50° from horizontal. After completing the 4-week training program, strength tests were repeated. Repeated-measures analysis of variance were used to compare EMG activity between muscles and to assess angle-specific strength improvements. Hamstring activity exceeded gluteus maximus activity for resisted hip extension, glider, and slider exercises (p < 0.001) but not for the diver (p = 0.087). Hamstring activation was greatest during the slider and resisted hip extension and lowest during the glider and the diver. Knee flexor strength improved by 9.0% (p = 0.005) but was not angle specific (training by angle p = 0.874). The short-term home training program effectively targeted the hamstrings and resulted in strength gains that were similar at short and long muscle lengths. These data demonstrate that hamstring strength can be improved using eccentrically biased unilateral exercises without the use of weights or other equipments.

  20. Effect of 3-Day Bed Rest on the Basal Sympathetic Activity and Responsiveness of this System to Physiological Stimuli In Athletes and Sedentary Subjects

    NASA Technical Reports Server (NTRS)

    Smorawinski, Jerzy; Adrian, Jacek; Kaciuba-Uscilko, Hanna; Nazar, Krystyna; Greenleaf, John E.; Dalton, P. Bonnie (Technical Monitor)

    2002-01-01

    The aims of this study were: (1) to examine the effect of three days of bed rest (BR) on basal plasma epinephrine [E] and norepinephrine [NE] and the catecholamine responses to various physiological stimuli, and (2) to find out whether previous physical activity modifies effects of BR. In the first series, 29 young men (11 sedentary students, 8 endurance and 10 strength trained athletes) were submitted to oral glucose tolerance test in supine position and to active orthostatic test before and after 3 days of BR. Plasma [E] and [NE] were measured after overnight fast (basal condition), at 60, 120 and 180 min after glucose ingestion (70 a), and at the 8th min of unsupported standing. In the second series, other 22 subjects (12 sedentary students, 10 endurance and 10 strength trained athletes) were submitted to 2 min cold pressor test (CPT) and exercise. Plasma E and NE were determined in the supine position after overnight fast and at 60th and 120th s of hand cooling. Then, after breakfast followed by 2-3 hour sitting, the subjects performed cycle ergometer exercise with workload increasing until volitional exhaustion. Plasma [E] and [NE] were determined at the end of each load. Plasma catecholamines were determined made radioenzymatically. After BR, basal plasma [NE] was decreased in endurance and strength athletes (p<0.01) but not in sedentary subjects. In neither group BR affected the basal [E]. Responses of both catecholamines to glucose load were diminished after BR in all three groups (p<0.05) but the effect was most pronounced in the endurance athletes. All subjects tolerated well 8-min standing although their heart rate response was increased after BR. Plasma catecholamine responses standing were not significantly affected by BR in either group but the plasma [NE] and [E] during standing were lowered after BR in endurance athletes (p<0.01). BR did not affect blood pressure and catecholamine responses to CPT. The pre- and post-exercise plasma catecholamines were similar before and after BR although the subjects achieved lower maximal loads after BR. In endurance athletes the threshold for plasma NA rise occurred at lower work intensity after than before BR (p<0.05).

  1. Comparison of 2 Different Exercise Approaches: Tai Chi Versus Otago, in Community-Dwelling Older Women.

    PubMed

    Son, Nam-Kuk; Ryu, Young Uk; Jeong, Hye-Won; Jang, Young-Hwan; Kim, Hyeong-Dong

    2016-01-01

    Regular exercise can delay age-related risk factors and can maintain or improve physical health and activity in older adults leading to a decrease in fall risk. The purpose of this study was to compare 2 different interventions for fall prevention, tai chi (TC) and Otago, by examining lower extremity strength, balance, and spatiotemporal gait parameters in community-dwelling older women. We performed a randomized trial in which subjects were assigned to 1 of 2 groups: the TC group (n = 21; age, 72.8 ± 4.7 years, range: 65-83 years), which participated in a modified Sun-style TC exercise program; and the Otago group (n = 24; age, 71.5 ± 3.6 years, range: 65-79 years), which participated in the Otago exercise program. The Timed Up and Go (TUG) test, functional reach (FR) test, one-leg standing (OLS) test, 5 times sit-to-stand test (5×STS), 30-second sit-to-stand (30s STS) test, and gait parameters (gait velocity, step length, step width, stride time, and cadence) were measured before and after the intervention. Both groups showed statistically significant improvements in balance (TUG and OLS tests), lower extremity strength (5×STS and 30s STS tests), and spatiotemporal gait parameters, except for step width and step length (P < .05). The Otago group showed a significantly improved FR, whereas the TC group showed a significantly improved step length after the intervention (P < .05). Furthermore, the Otago group exhibited greater improvements in the TUG (P < .001), FR (P < .001), 5×CST (P < .01), and 30-second CST (P < .01) tests: a faster cadence (P < .001) and shorter stride time (P < .001) when compared with the TC group. The TC group showed greater improvements in the OLS test, step length, and step width (P < .01) and faster gait velocity (P < .05) than the Otago group. The findings from this study support the efficacy of the TC and Otago exercise programs in improving mobility in this sample of subjects. Furthermore, the Otago group showed greater improvement in lower extremity strength, whereas the TC group showed greater improvement in balance (OLS test). Also, the TC group showed a greater improvement in gait velocity after TC training program compared with the Otago exercise program. However, this study does not elucidate which exercise program is a more effective intervention method with older women for fall prevention.

  2. The effects of water-based exercise in combination with blood flow restriction on strength and functional capacity in post-menopausal women.

    PubMed

    Araújo, Joamira P; Neto, Gabriel R; Loenneke, Jeremy P; Bemben, Michael G; Laurentino, Gilberto C; Batista, Gilmário; Silva, Júlio C G; Freitas, Eduardo D S; Sousa, Maria S C

    2015-12-01

    Water-based exercise and low-intensity exercise in combination with blood flow restriction (BFR) are two methods that have independently been shown to improve muscle strength in those of advancing age. The objective of this study was to assess the long-term effect of water-based exercise in combination with BFR on maximum dynamic strength and functional capacity in post-menopausal women. Twenty-eight women underwent an 8-week water-based exercise program. The participants were randomly allocated to one of the three groups: (a) water exercise only, (b) water exercise + BFR, or (c) a non-exercise control group. Functional capacity (chair stand test, timed up and go test, gait speed, and dynamic balance) and strength testing were tested before and after the 8-week aquatic exercise program. The main findings were as follows: (1) water-based exercise in combination with BFR significantly increased the lower limb maximum strength which was not observed with water-based exercise alone and (2) water-based exercise, regardless of the application of BFR, increased functional performance measured by the timed up and go test over a control group. Although we used a healthy population in the current study, these findings may have important implications for those who may be contraindicated to using traditional resistance exercise. Future research should explore this promising modality in these clinical populations.

  3. Body composition explains sex differential in physical performance among older adults.

    PubMed

    Tseng, Lisa A; Delmonico, Matthew J; Visser, Marjolein; Boudreau, Robert M; Goodpaster, Bret H; Schwartz, Ann V; Simonsick, Eleanor M; Satterfield, Suzanne; Harris, Tamara; Newman, Anne B

    2014-01-01

    Older women have higher percent body fat, poorer physical function, lower strength, and higher rates of nonfatal chronic conditions than men. We sought to determine whether these differences explained physical performance differences between men and women. Physical performance was assessed in the Health, Aging and Body Composition study in 2,863 men and women aged 70-79 with a composite 0-4 point score consisting of chair stands, standing balance including one-leg stand, and 6-m usual and narrow walk tests. Total body composition was measured by dual x-ray absorptiometry, thigh composition by computed tomography, and knee extensor strength by isokinetic dynamometer. Analysis of covariance estimated least square mean performance scores for men and women. Men had higher performance scores than women (least square means: 2.33±0.02 vs 2.03±0.02, p < .0001), adjusted for race, study site, age, and height. Body composition measures (total body fat and thigh muscle area, muscle density, subcutaneous fat, and intermuscular fat) accounted for differences between men and women (least square means: 2.15±0.02 vs 2.17±0.02, p = .53). Higher strength in men partly explained the sex difference (least square means: 2.28±0.02 vs 2.12±0.02, p < .0001). Strength attenuated the association of thigh muscle mass with performance. Chronic health conditions did not explain the sex difference. In a well-functioning cohort, poorer physical function in women compared with men can be explained predominantly by their higher fat mass, but also by other body composition differences. The higher proportion of body fat in women may put them at significant biomechanical disadvantage for greater disability in old age.

  4. Coupled effects of wind-storms and drought on tree mortality across 115 forest stands from the Western Alps and the Jura mountains.

    PubMed

    Csilléry, Katalin; Kunstler, Georges; Courbaud, Benoît; Allard, Denis; Lassègues, Pierre; Haslinger, Klaus; Gardiner, Barry

    2017-12-01

    Damage due to wind-storms and droughts is increasing in many temperate forests, yet little is known about the long-term roles of these key climatic factors in forest dynamics and in the carbon budget. The objective of this study was to estimate individual and coupled effects of droughts and wind-storms on adult tree mortality across a 31-year period in 115 managed, mixed coniferous forest stands from the Western Alps and the Jura mountains. For each stand, yearly mortality was inferred from management records, yearly drought from interpolated fields of monthly temperature, precipitation and soil water holding capacity, and wind-storms from interpolated fields of daily maximum wind speed. We performed a thorough model selection based on a leave-one-out cross-validation of the time series. We compared different critical wind speeds (CWSs) for damage, wind-storm, and stand variables and statistical models. We found that a model including stand characteristics, drought, and storm strength using a CWS of 25 ms -1 performed the best across most stands. Using this best model, we found that drought increased damage risk only in the most southerly forests, and its effect is generally maintained for up to 2 years. Storm strength increased damage risk in all forests in a relatively uniform way. In some stands, we found positive interaction between drought and storm strength most likely because drought weakens trees, and they became more prone to stem breakage under wind-loading. In other stands, we found negative interaction between drought and storm strength, where excessive rain likely leads to soil water saturation making trees more susceptible to overturning in a wind-storm. Our results stress that temporal data are essential to make valid inferences about ecological impacts of disturbance events, and that making inferences about disturbance agents separately can be of limited validity. Under projected future climatic conditions, the direction and strength of these ecological interactions could also change. © 2017 John Wiley & Sons Ltd.

  5. Motor performance in Prader-Willi syndrome patients and its potential influence on caregiver's quality of life.

    PubMed

    Chiu, Valeria Jia-Yi; Tsai, Li-Ping; Wei, Jang-Ting; Tzeng, I-Shiang; Wu, Hsin-Chi

    2017-01-01

    Prader-Willi syndrome (PWS) is a complex, multisystem genetic disorder characterized by a variety of physical, cognitive, and behavioral impairments. PWS is a unique sarcopenia model characterized by an abnormal increase in body fat mass and a decrease in muscle mass that predisposes patients to reduced physical activity, functional limitations, and disability. These manifestations may require both symptomatic and supportive management, thus negatively influencing their lifelong family caregiver's quality of life. The aim of this study was to examine the functional motor performance of adults with PWS in Taiwan and to measure the quality of life of their primary family caregivers. The functional motor tests consisted of the following: (1) 30-s sit-to-stand test, (2) timed up-and-go test, (3) hand grip and lateral pinch strength tests, and (4) Berg Balance Scale. The World Health Organization Quality of Life-short form (WHOQOL-BREF) and the Short-Form 36 Health Survey Questionnaire (SF-36) were used to evaluate health-related quality of life, and the parenting stress index was used to assess the magnitude of stress within the parent-child system. The participants included seven adults (two females and five males) with genetically confirmed PWS and their respective main caregivers. The mean age of the adults with PWS was 25.28 years; range 18-31 years, SD 5.10; the mean BMI was 29.2 kg/m 2 , SD 6.43. All adults with PWS showed lower hand grip and lateral pinch strengths, fewer sit-to-stand cycles during the 30-s chair stand test, and greater average time during the timed up-and-go test when compared to the normative data on healthy adults. Balance was negatively correlated with the caregiver's health concepts of social functioning ( r s -0.879, P  = 0.009) and with role limitations due to physical problems ( r s -0.899, P  = 0.006) and emotional problems ( r s -0.794, P  = 0.033); hand grip strength was negatively correlated with bodily pain ( r s -0.800, P  = 0.031), as assessed using the SF-36 questionnaire. The timed up-and-go test was positively correlated with the social relationship domain ( r s 0.831, P  = 0.021), as assessed using the WHOQOL-BREF questionnaire. The parenting stress index showed no association with the PWS patient's physical activities. All adults with PWS showed decreased upper and lower limb strength and functional mobility when compared to healthy adults. Some of their motor performance might have negative effects on their primary family members in terms of social participation and physical and emotional role limitations. Future research should explore the relationship between physical performances, psychological difficulties of PWS and caregiver's QOL.

  6. The assessment of preschool children's motor skills after familiarization with motor tests.

    PubMed

    Tomac, Zvonimir; Hraski, Zeljko; Sporis, Goran

    2012-07-01

    This research study was conducted to establish the influence of familiarization on the information component of movement in a motor task for the assessment of preschool children's motor skills. The sample included 50 children whose mean age was 5.9 years (71.5 months). The experimental group consisted of 27 children who were 5.9 years (71.5 months) old, and the control group consisted of 23 children who were 5.9 years (71.5 months) old. The examinees performed 2 motor tasks, standing long jump (SJ, explosive strength) and standing on 1 leg on a beam "flamingo test" (FT, balance). The experimental group underwent a period of familiarization with the motor task in 3 sessions with 5 trials every 3 days. The results indicate statistically significant differences in the final testing between both groups of examinees; the experimental group mean was 112.73 cm, and the control group mean was 100.62 in the SJ test (p = 0.00), and the experimental group mean was 27.10 seconds and the control group mean was 15.01 seconds in the FT (for balance) (p = 0.00). The results obtained in this research indicate that children significantly improved the results in the motor test of strength and balance, being influenced by familiarization. It was confirmed that it was necessary for preschool children to be familiar with the test and it is not justified to use testing and assessment protocols and standards for adults. Physical educators and coaches, when testing preschool children, should introduce children to tests to obtain the best result.

  7. Investigating innovative means of prompting activity uptake in older adults with type 2 diabetes: a feasibility study of exergaming.

    PubMed

    Senior, Hugh; Henwood, Tim; DE Souza, Daniel; Mitchell, Geoffrey

    2016-10-01

    Physical activity is effective in improving glycemic control in diabetes mellitus. Yet only 40% of people meet the recommended level of physical activity. Nintendo Wii tennis has an energy expenditure of moderate intensity, and may be a viable part of a physical activity programme. Eleven older people with diabetes who were sedentary participated in a pre-post-test designed study to examine physical activity levels, muscle strength, and physical performance after 4 weeks of group Nintendo Wii training. Significant effects occurred on moderate physical activity time, total physical activity, dominant handgrip strength, non-dominant handgrip strength, 30 second chair stand and 400m walk test. No effect was observed for BMI, quality of life, or balance. This study provided preliminary evidence of the effectiveness of group-based active video game programme on physical activity levels.

  8. Correlation between compressive strength and ultrasonic pulse velocity of high strength concrete incorporating chopped basalt fibre

    NASA Astrophysics Data System (ADS)

    Shafiq, Nasir; Fadhilnuruddin, Muhd; Elshekh, Ali Elheber Ahmed; Fathi, Ahmed

    2015-07-01

    Ultrasonic pulse velocity (UPV), is considered as the most important test for non-destructive techniques that are used to evaluate the mechanical characteristics of high strength concrete (HSC). The relationship between the compressive strength of HSC containing chopped basalt fibre stands (CBSF) and UPV was investigated. The concrete specimens were prepared using a different ratio of CBSF as internal strengthening materials. The compressive strength measurements were conducted at the sample ages of 3, 7, 28, 56 and 90 days; whilst, the ultrasonic pulse velocity was measured at 28 days. The result of HSC's compressive strength with the chopped basalt fibre did not show any improvement; instead, it was decreased. The UPV of the chopped basalt fibre reinforced concrete has been found to be less than that of the control mix for each addition ratio of the basalt fibre. A relationship plot is gained between the cube compressive strength for HSC and UPV with various amounts of chopped basalt fibres.

  9. Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test.

    PubMed

    Doheny, Emer P; Walsh, Cathal; Foran, Timothy; Greene, Barry R; Fan, Chie Wei; Cunningham, Clodagh; Kenny, Rose Anne

    2013-09-01

    The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 with a history of falls, performed four repetitions of the FTSS in their homes. A tri-axial accelerometer was attached to the lateral thigh and used to identify each sit-stand-sit phase and sit-stand and stand-sit transitions. A second tri-axial accelerometer, attached to the sternum, captured torso acceleration. The mean and variation of the root-mean-squared amplitude, jerk and spectral edge frequency of the acceleration during each section of the assessment were examined. The test-retest reliability of each feature was examined using intra-class correlation analysis, ICC(2,k). A model was developed to classify participants according to falls status. Only features with ICC>0.7 were considered during feature selection. Sequential forward feature selection within leave-one-out cross-validation resulted in a model including four reliable accelerometer-derived features, providing 74.4% classification accuracy, 80.0% specificity and 68.7% sensitivity. An alternative model using FTSS time alone resulted in significantly reduced classification performance. Results suggest that the described methodology could provide a robust and accurate falls risk assessment. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Physical fitness of overweight and underweight preschool children from southern Poland.

    PubMed

    Kryst, Łukasz; Woronkowicz, Agnieszka; Jankowicz-Szymańska, Agnieszka; Pociecha, Mariusz; Kowal, Małgorzata; Sobiecki, Jan; Brudecki, Janusz; Żarów, Ryszard

    The main aim of this study was to assess differences in the level of physical fitness between children of preschool age with different BMI, as overweight and obesity are an increasing problem even in this age group. The study group consisted of 3,945 children aged 4 to 6 years living in southern Poland. Analysis included the results of body height and weight measurements (from which BMI was calculated) and motor skills tests: sit-and-reach test, standing broad jump and handgrip strength. Children were grouped according to the Obesity Task Force categories. Significant differences in body height were visible (i) between overweight and normal children and (ii) between overweight and underweight children. In terms of body weight and BMI, significant differences existed between all groups. With regard to fitness tests, the greatest differences were observed for handgrip strength and standing broad jump. The sit-and-reach test did not reveal any differences between the groups. The results showed that overall physical fitness was negatively correlated with relative weight; general fitness in overweight children was lower than in normal or underweight children. As it is obvious that physical activity is indispensable even for preschool children, any increase in physical activity could at least partially alleviate the problem of excessive weight and improve the general fitness of children. In the future this would reduce the incidence of diseases related to obesity and a lack of exercise.

  11. Elasticity Modulus and Flexural Strength Assessment of Foam Concrete Layer of Poroflow

    NASA Astrophysics Data System (ADS)

    Hajek, Matej; Decky, Martin; Drusa, Marian; Orininová, Lucia; Scherfel, Walter

    2016-10-01

    Nowadays, it is necessary to develop new building materials, which are in accordance to the principles of the following provisions of the Roads Act: The design of road is a subject that follows national technical standards, technical regulations and objectively established results of research and development for road infrastructure. Foam concrete, as a type of lightweight concrete, offers advantages such as low bulk density, thermal insulation and disadvantages that will be reduced by future development. The contribution focuses on identifying the major material characteristics of foam concrete named Poroflow 17-5, in order to replace cement-bound granular mixtures. The experimental measurements performed on test specimens were the subject of diploma thesis in 2015 and continuously of the dissertation thesis and grant research project. At the beginning of the contribution, an overview of the current use of foam concrete abroad is elaborated. Moreover, it aims to determine the flexural strength of test specimens Poroflow 17-5 in combination with various basis weights of the underlying geotextile. Another part of the article is devoted to back-calculation of indicative design modulus of Poroflow based layers based on the results of static plate load tests provided at in situ experimental stand of Faculty of Civil Engineering, University of Žilina (FCE Uniza). Testing stand has been created in order to solve problems related to research of road and railway structures. Concern to building construction presents a physical homomorphic model that is identical with the corresponding theory in all structural features. Based on the achieved material characteristics, the tensile strength in bending of previously used road construction materials was compared with innovative alternative of foam concrete and the suitability for the base layers of pavement roads was determined.

  12. The Effect of Aerobic or Aerobic-Strength Exercise on Body Composition and Functional Capacity in Patients with BMI ≥35 after Bariatric Surgery: a Randomized Control Trial.

    PubMed

    Hassannejad, Alireza; Khalaj, Alireza; Mansournia, Mohammad Ali; Rajabian Tabesh, Mastaneh; Alizadeh, Zahra

    2017-11-01

    Although previous studies suggested that bariatric surgery is the most effective and sustainable treatment method for morbid obesity in long term, but without changing in lifestyle, maintaining optimal weight loss is almost impossible. Sixty morbid obese patients (BMI ≥ 35) were evaluated before and after 12 weeks of bariatric surgery in order to compare the impact of two different exercise programs on body composition and functional capacity outcomes. Participants were divided into three groups: aerobic (A), aerobic-strength (AS), and control (C) group. Aerobic capacity was assessed with 12-min walk-run test (12MWRT). One-repetition maximum (1RM) test was performed to evaluation upper limb muscle strength. Lower extremity functional capacity was assessed by sit-to-stand test. Weight, percent body fat (PBF), and fat mass (FM) reduced greater in the trial groups in comparison to the C group (P < 0.05). In the AS group, the reduction of fat-free mass (FFM) was significantly lower than that in the other groups. Mean changes in 12MWRT increased significantly in the intervention groups. The mean change in the sit-to-stand scores was not statistically significant between the three groups. Comparing the intervention groups showed that mean changes in 1RM variables increased in AS group (P = 0.03). The data suggests a positive effect of exercise on weight and PBF decrease after surgery, and it leads to significant improvement on aerobic capacity. Moreover, doing resisted exercise caused greater preserving of lean mass.

  13. Microhardness Testing of Aluminum Alloy Welds

    NASA Technical Reports Server (NTRS)

    Bohanon, Catherine

    2009-01-01

    A weld is made when two pieces of metal are united or fused together using heat or pressure, and sometimes both. There are several different types of welds, each having their own unique properties and microstructure. Strength is a property normally used in deciding which kind of weld is suitable for a certain metal or joint. Depending on the weld process used and the heat required for that process, the weld and the heat-affected zone undergo microstructural changes resulting in stronger or weaker areas. The heat-affected zone (HAZ) is the region that has experienced enough heat to cause solid-state microstructural changes, but not enough to melt the material. This area is located between the parent material and the weld, with the grain structure growing as it progresses respectively. The optimal weld would have a short HAZ and a small fluctuation in strength from parent metal to weld. To determine the strength of the weld and decide whether it is suitable for the specific joint certain properties are looked at, among these are ultimate tensile strength, 0.2% offset yield strength and hardness. Ultimate tensile strength gives the maximum load the metal can stand while the offset yield strength gives the amount of stress the metal can take before it is 0.2% longer than it was originally. Both of these are good tests, but they both require breaking or deforming the sample in some way. Hardness testing, however, provides an objective evaluation of weld strengths, and also the difference or variation in strength across the weld and HAZ which is difficult to do with tensile testing. Hardness is the resistance to permanent or plastic deformation and can be taken at any desired point on the specimen. With hardness testing, it is possible to test from parent metal to weld and see the difference in strength as you progress from parent material to weld. Hardness around grain boundaries and flaws in the material will show how these affect the strength of the metal while still retaining the sample. This makes hardness testing a good test for identifying grain size and microstructure.

  14. Reliability and validity of selected measures associated with increased fall risk in females over the age of 45 years with distal radius fracture - A pilot study.

    PubMed

    Mehta, Saurabh P; MacDermid, Joy C; Richardson, Julie; MacIntyre, Norma J; Grewal, Ruby

    2015-01-01

    Clinical measurement. This study examined test-retest reliability and convergent/divergent construct validity of selected tests and measures that assess balance impairment, fear of falling (FOF), impaired physical activity (PA), and lower extremity muscle strength (LEMS) in females >45 years of age after the distal radius fracture (DRF) population. Twenty one female participants with DRF were assessed on two occasions. Timed Up and Go, Functional Reach, and One Leg Standing tests assessed balance impairment. Shortened Falls Efficacy Scale, Activity-specific Balance Confidence scale, and Fall Risk Perception Questionnaire assessed FOF. International Physical Activity Questionnaire and Rapid Assessment of Physical Activity were administered to assess PA level. Chair stand test and isometric muscle strength testing for hip and knee assessed LEMS. Intraclass correlation coefficients (ICC) examined the test-retest reliability of the measures. Pearson correlation coefficients (r) examined concurrent relationships between the measures. The results demonstrated fair to excellent test-retest reliability (ICC between 0.50 and 0.96) and low to moderate concordance between the measures (low if r ≤ 0.4; moderate if r = 0.4-0.7). The results provide preliminary estimates of test-retest reliability and convergent/divergent construct validity of selected measures associated with increased risk for falling in the females >45 years of age after DRF. Further research directions to advance knowledge regarding fall risk assessment in DRF population have been identified. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  15. Effects Of Silvicultural Practice And Veneer Lay Upon Some Mechanical Properties Of Loblolly Pine Plywood

    Treesearch

    Todd F. Shupe; Chung Y. Hse; George A. Grozdits; Elvin T. Choong

    1997-01-01

    Loblolly pine three-ply plywood was manufactured from veneer obtained from silviculturally different stands. Panels from each site were assembled with four different veneer grade arrangements and tested in wet and dry conditions. Stiffness properties in both the wet and dry conditions and strength properties in the dry condition were all significantly affected by...

  16. Effects of silviculture practice and veneer layup on some mechanical properties of loblolly pine plywood

    Treesearch

    Todd E. Shupe; Chung Y. Hse; George A. Grozdits; Elvin T. Choong

    1997-01-01

    Loblolly pine three-ply plywood was manufactured from veneer obtained from silviculturally different stands. Panels from each site were assembled with four different veneer grade arrangements and tested in wet and dry conditions. Stiffness properties in both the wet and dry conditions and strength properties in the dry condition were all significantly affected by...

  17. The Relationship Between Maximum Unilateral Squat Strength and Balance in Young Adult Men and Women

    PubMed Central

    McCurdy, Kevin; Langford, George

    2006-01-01

    The purpose of this study was to determine the relationship between unilateral squat strength and measures of static balance to compare balance performance between the dominant and non-dominant leg. Seventeen apparently healthy men (mean mass 90.5 ± 20.9 kg and age 21.7 ± 1.8 yrs) and 25 women (mean mass 62.2 ± 14.5 kg and age 21.9 ± 1.3 yrs) completed the study. Weight bearing unilateral strength was measured with a 1RM modified unilateral squat on the dominant and non-dominant leg. The students completed the stork stand and wobble board tests to determine static balance on the dominant and non-dominant leg. Maximum time maintained in the stork stand position, on the ball of the foot with the uninvolved foot against the involved knee with hands on the hips, was recorded. Balance was measured with a 15 second wobble board test. No significant correlations were found between the measurements of unilateral balance and strength (r values ranged between -0.05 to 0.2) for the men and women. Time off balance was not significantly different between the subjects’ dominant (men 1.1 ± 0.4 s; women 0.3 ± 0.1 s) and non-dominant (men 0.9 ± 0.3 s; women 0.3 ± 0.1 s) leg for the wobble board. Similar results were found for the time balanced during the stork stand test on the dominant (men 26.4 ± 6.3 s; women 24.1 ± 5.6 s) and non-dominant (men 26.0 ± 5.7 s; women 21.3 ± 4.1 s) leg. The data indicate that static balance and strength is unrelated in young adult men and women and gains made in one variable after training may not be associated with a change in performance of the other variable. These results also suggest that differences in static balance performance between legs can not be determined by leg dominance. Similar research is needed to compare contralateral leg balance in populations who participate in work or sport activities requiring repetitive asymmetrical use. A better understanding of contralateral balance performance will help practitioners make evaluative decisions during the rehabilitation process. Key Points 1RM unilateral squat strength is unrelated to measures of unilateral static balance in young adult men and women Static balance is similar between the dominant and non-dominant leg in young adult men and women Side-to-side differences in balance warrant assessment and training to correct imbalances prior to participation in activities that present a high risk for injury. PMID:24260001

  18. An ergonomics prototype of adjustable chin stands aid for visual mechanical inspection at electronic manufacturing-based company in Kuantan, Malaysia

    NASA Astrophysics Data System (ADS)

    Elias, Nurainaa; Mat Yahya, Nafrizuan

    2018-04-01

    Chin stands aid is a device designed to reduce fatigue on the chin during the Visual Mechanical Inspection (VMI) task for operators in TT Electronic Sdn Bhd, Kuantan, Malaysia. It is also used to reduce cycle time and also improve employee well-being in terms of comfort. In this project, a 3D model of chin stands aid with an ergonomics approach is created using SOLIDWORKS software. Two different concepts were designed and the best one is chosen based on the Pugh concept selection method, concept screening and also concept scoring. After the selection of concepts is done, a prototype of chin stands aid will be developed and a simulation of the prototype is performed. The simulation has been executed by using Workbench ANSYS software as a tool. Stress analysis, deformation analysis, and fatigue analysis have been done to know the strength and lifespan of the product. The prototype also has been tested to know the functionality and also comfortability for the user to use the chin stands aid.

  19. A community-based aquatic exercise program to improve endurance and mobility in adults with mild to moderate intellectual disability.

    PubMed

    Hakim, Renée M; Ross, Michael D; Runco, Wendy; Kane, Michael T

    2017-02-01

    The purpose of this study was to investigate the impact of a community-based aquatic exercise program on physical performance among adults with mild to moderate intellectual disability (ID). Twenty-two community-dwelling adults with mild to moderate ID volunteered to participate in this study. Participants completed an 8-week aquatic exercise program (2 days/wk, 1 hr/session). Measures of physical performance, which were assessed prior to and following the completion of the aquatic exercise program, included the timed-up-and-go test, 6-min walk test, 30-sec chair stand test, 10-m timed walk test, hand grip strength, and the static plank test. When comparing participants' measures of physical performance prior to and following the 8-week aquatic exercise program, improvements were seen in all measures, but the change in scores for the 6-min walk test, 30-sec chair stand test, and the static plank test achieved statistical significance ( P <0.05). An 8-week group aquatic exercise program for adults with ID may promote improvements in endurance and balance/mobility.

  20. Coimpairments: strength and balance as predictors of severe walking disability.

    PubMed

    Rantanen, T; Guralnik, J M; Ferrucci, L; Leveille, S; Fried, L P

    1999-04-01

    Little information is available on the joint effects of multiple impairments (coimpairments) on the risk of disability. Our aim was to study the joint effects of strength and balance impairments on severe walking disability. The data are from the baseline of the Women's Health and Aging Study (WHAS), a study of moderately to severely disabled women. A total of 1,002 women aged 65 and older participated in the tests, which took place in their homes. Severe walking disability was defined as self-reported inability to walk one-quarter mile and customary walking speed in a 4-meter test of < or =0.4 m/s. Balance was measured as an ability to hold progressively more difficult stands (feet side-by-side, semitandem and tandem stands). Maximal knee extension strength was measured using a hand-held dynamometer. There were 129 women who were severely walking disabled but able to walk at least minimally. In logistic regression analysis, balance and knee extension strength were independent predictors of severe walking disability. To study the combined effects, nine groups were formed on the basis of strength tertiles by balance categories in the entire population. In the best balance category, the crude prevalences of severe walking disability were 1.2%, 4.9%, and 14.3% in the highest to lowest strength tertiles. In the middle balance category, the rates were 2.9%, 10.0%, and 45.4.1%, and in the poorest balance category 4.9%, 22.1%, and 42.6%, correspondingly. The age, body weight, and height-adjusted odds ratios (OR) showed that the risk of severe walking disability in the subgroup with best balance and strength was less than 5% of the risk in the subgroup with poorest balance and strength (OR .034, 95% confidence interval [CI] .007-.166). Correspondingly, in the subgroups with poorest strength and best balance (OR .097, 95% CI .025-.38) or poorest balance and best strength (OR .102, 95% CI .012-.866) the risk was about 10%. The age-specific estimates of prevalence of severe walking disability in women were: 2.0% for ages 65-74 years, 3.4% for ages 75-84 years, and 9.1% for ages 85 years and older. The burden of coimpairments seems to be greater than the sum of single impairments involved. An effective way to reduce severe disabilities could be prevention of coimpairments.

  1. Ageing influence in the evolution of strength and muscle mass in women with fibromyalgia: the al-Ándalus project.

    PubMed

    Latorre-Román, Pedro Ángel; Segura-Jiménez, Víctor; Aparicio, Virginia A; Santos E Campos, María Aparecida; García-Pinillos, Felipe; Herrador-Colmenero, Manuel; Álvarez-Gallardo, Inmaculada C; Delgado-Fernández, Manuel

    2015-07-01

    Fibromyalgia is associated with physical disabilities in daily activities. Moreover, patients with fibromyalgia present similar levels of functional capacity and physical condition than elderly people. The aim of this study was to analyse the evolution of strength and muscle mass in women with fibromyalgia along ageing. A total sample of 492 fibromyalgia patients and 279 healthy control women were included in the study. Participants in each group were further divided into four age subgroups: subgroup 1: 30-39 years old, subgroup 2: 40-49 years old, subgroup 3: 50-59 years old and subgroup 4: 60-69 years old. Standardized field-based fitness tests were used to assess muscle strength (30-s chair stand, handgrip strength and arm curl tests). Fibromyalgia patients did not show impairment on muscle mass along ageing, without values of skeletal muscle mass index below 6.76 kg/m(2) in any group. However, in all variables of muscle strength, the fibromyalgia group showed less strength than the healthy group (p < 0.05) for all age groups. As expected, handgrip strength test showed differences along ageing only in the fibromyalgia group (p < 0.001). Age was inversely associated with skeletal muscle mass (r = -0.155, p < 0.01) and handgrip strength (r = -0.230, p < 0.001) in the FM group. Women with fibromyalgia showed a reduction in muscle strength along ageing process, with significantly lower scores than healthy women for each age group, representing a risk of dynapenia.

  2. Saturn Apollo Program

    NASA Image and Video Library

    1967-07-28

    This photograph depicts a view of the test firing of all five F-1 engines for the Saturn V S-IC test stage at the Marshall Space Flight Center. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. The S-IC Static Test Stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level, and was required to hold down the brute force of the 7,500,000-pound thrust. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900-ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minutes

  3. Saturn Apollo Program

    NASA Image and Video Library

    1965-05-01

    This photograph depicts a view of the test firing of all five F-1 engines for the Saturn V S-IC test stage at the Marshall Space Flight Center. The S-IC stage is the first stage, or booster, of a 364-foot long rocket that ultimately took astronauts to the Moon. Operating at maximum power, all five of the engines produced 7,500,000 pounds of thrust. The S-IC Static Test Stand was designed and constructed with the strength of hundreds of tons of steel and cement, planted down to bedrock 40 feet below ground level, and was required to hold down the brute force of the 7,500,000-pound thrust. The structure was topped by a crane with a 135-foot boom. With the boom in the up position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. When the Saturn V S-IC first stage was placed upright in the stand , the five F-1 engine nozzles pointed downward on a 1,900-ton, water-cooled deflector. To prevent melting damage, water was sprayed through small holes in the deflector at the rate 320,000 gallons per minutes.

  4. Effects of a Pilates exercise program on muscle strength, postural control and body composition: results from a pilot study in a group of post-menopausal women.

    PubMed

    Bergamin, M; Gobbo, S; Bullo, V; Zanotto, T; Vendramin, B; Duregon, F; Cugusi, L; Camozzi, V; Zaccaria, M; Neunhaeuserer, D; Ermolao, A

    2015-12-01

    Participation in exercise programs is heartily recommended for older adults since the level of physical fitness directly influences functional independence. The aim of this present study was to investigate the effects of supervised Pilates exercise training on the physical function, hypothesizing that a period of Pilates exercise training (PET) can increase overall muscle strength, body composition, and balance, during single and dual-task conditions, in a group of post-menopausal women. Twenty-five subjects, aged 59 to 66 years old, were recruited. Eligible participants were assessed prior and after 3 months of PET performed twice per week. Muscular strength was evaluated with handgrip strength (HGS) test, 30-s chair sit-to-stand test (30CST), and abdominal strength (AST) test. Postural control and dual-task performance were measured through a stabilometric platform while dynamic balance with 8 ft up and go test. Finally, body composition was assessed by means of dual-energy X-ray absorptiometry. Statistically significant improvements were detected on HGS (+8.22%), 30CST (+23.41%), 8 ft up and go test (-5.95%), AST (+30.81%), medio-lateral oscillations in open eyes and dual-task condition (-22.03% and -10.37%). Pilates was effective in increasing upper body, lower body, and abdominal muscle strength. No changes on body composition were detected. Results on this investigation indicated also that 12-week of mat Pilates is not sufficient to determine a clinical meaningful improvement on static balance in single and dual-task conditions.

  5. Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

    PubMed

    Jung, Hungu; Yamasaki, Masahiro

    2016-12-08

    Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.

  6. Impact of a community-based exercise programme on physical fitness in middle-aged and older patients with type 2 diabetes.

    PubMed

    Mendes, Romeu; Sousa, Nelson; Themudo-Barata, José; Reis, Victor

    2016-01-01

    Physical fitness is related to all-cause mortality, quality of life and risk of falls in patients with type 2 diabetes. This study aimed to analyse the impact of a long-term community-based combined exercise program (aerobic+resistance+agility/balance+flexibility) developed with minimum and low-cost material resources on physical fitness in middle-aged and older patients with type 2 diabetes. This was a non-experimental pre-post evaluation study. Participants (N=43; 62.92±5.92 years old) were engaged in a community-based supervised exercise programme (consisting of combined aerobic, resistance, agility/balance and flexibility exercises; three sessions per week; 70min per session) of 9 months' duration. Aerobic fitness (6-Minute Walk Test), muscle strength (30-Second Chair Stand Test), agility/balance (Timed Up and Go Test) and flexibility (Chair Sit and Reach Test) were assessed before (baseline) and after the exercise intervention. Significant improvements in the performance of the 6-Minute Walk Test (Δ=8.20%, p<0.001), 30-Second Chair Stand Test (Δ=28.84%, p<0.001), Timed Up and Go Test (Δ=14.31%, p<0.001), and Chair Sit and Reach Test (Δ=102.90%, p<0.001) were identified between baseline and end-exercise intervention time points. A long-term community-based combined exercise programme, developed with low-cost exercise strategies, produced significant benefits in physical fitness in middle-aged and older patients with type 2 diabetes. This supervised group exercise programme significantly improved aerobic fitness, muscle strength, agility/balance and flexibility, assessed with field tests in community settings. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  7. Worse self-reported outcomes but no limitations in performance-based measures in patients with long-standing hip and groin pain compared with healthy controls.

    PubMed

    Wörner, Tobias; Sigurðsson, Haraldur B; Pålsson, Anders; Kostogiannis, Ioannis; Ageberg, Eva

    2017-01-01

    This study aimed to evaluate patient-reported outcomes as well as lower extremity and trunk muscle function in patients with long-standing hip and groin pain, in comparison with matched, healthy controls. It was hypothesized that patients with long-standing hip and groin pain would report more deficiency on the Copenhagen Hip and Groin Outcome Score (HAGOS) and have worse outcomes on performance-based measures than healthy controls. Nineteen patients with long-standing hip and groin pain and 19 healthy, activity level-, age-, gender-, and weight-matched controls were assessed with the HAGOS for self-reported outcomes, and a parallel squat (w/kg), single-leg triple jump (cm), single-leg rise (n), barbell roll-out (% of height), and plank test (s) for performance-based measures. Independent sample t test was performed to assess between-group differences. The paired t test was used to analyse between-limb differences in unilateral performance tasks. The patients had worse scores than the controls in all HAGOS subscales (p ≤ 0.001), while no statistically significant differences were observed for any performance measure between groups or between symptomatic and non-symptomatic limbs. Despite significant self-reported functional limitations on the HAGOS, there were no significant differences between groups in performance-based strength or power measures. The results of this study highlight the need to identify performance-based measures, sensitive to functional deficiencies in patients with long-standing hip and groin pain in order to complement the clinical picture obtained by patient-reported outcomes such as the HAGOS. III.

  8. Surface soil root distribution and possible interaction with site factors in a young longleaf pine stand

    Treesearch

    Mary Anne Sword Sayer

    2013-01-01

    Interaction between soil bulk density and low soil water content may create root growth-limiting soil strengths. In a Louisiana longleaf pine (Pinus palustris Mill.) stand, soil strength at the zero- to 20.0-cm depth was assessed in response to no fire or biennial fires in May. At the 5.0- to 20.0-cm depth, one-half of the measurements were...

  9. The Effect of Therapeutic Exercise on Long-Standing Adductor-Related Groin Pain in Athletes: Modified Hölmich Protocol

    PubMed Central

    Yousefzadeh, Abbas; Olyaei, Gholam Reza; Naseri, Nasrin; Khazaeipour, Zahra

    2018-01-01

    Objective The Hölmich protocol in therapeutic exercise is the most appropriate method for the treatment of long-standing adductor-related groin pain (LSAGP). Herein, we evaluated a modified Hölmich protocol to resolve the possible limitations intrinsic to the Hölmich protocol in terms of the rate of return to sport and the recovery period for athletes with LSAGP. Design The study followed a single-blind, before/after study design, where 15 athletes with LSAGP (mean age = 26.13 years; SD = 4.48) performed a 10-week modified Hölmich therapeutic exercise protocol. Results Outcome scores related to pain, hip adductor and abductor muscle strengths, and the ratio of maximum isometric and eccentric hip adduction to abduction strength increased significantly. Likewise, hip abduction and internal rotation ROM improved significantly compared to that at baseline. Furthermore, functional records (t-test, Edgren Side Step Test, and Triple Hop Test) showed significant improvement after treatment. Finally, 13 athletes (86.6% of the participants) successfully returned to sports activity in a mean time of 12.06 weeks (SD = 3.41). Conclusion The findings of this study objectively show that the modified Hölmich protocol may be safer and more effective than the Hölmich protocol in athletes with LSAGP in promoting their return to sports activity. This trial is registered with  IRCT2016080829269N1. PMID:29721339

  10. Assessment of a model of forest dynamics under contrasting climate and disturbance regimes in the Pacific Northwest [FORCLIM

    USGS Publications Warehouse

    Busing, Richard T.; Solomon, Allen M.

    2005-01-01

    An individual-based model of forest dynamics (FORCLIM) was tested for its ability to simulate forest composition and structure in the Pacific Northwest region of North America. Simulation results across gradients of climate and disturbance were compared to forest survey data from several vegetation zones in western Oregon. Modelled patterns of tree species composition, total basal area and stand height across climate gradients matched those in the forest survey data. However, the density of small stems (<50 cm DBH) was underestimated by the model. Thus actual size-class structure and other density-based parameters of stand structure were not simulated with high accuracy. The addition of partial-stand disturbances at moderate frequencies (<0.01 yr-1) often improved agreement between simulated and actual results. Strengths and weaknesses of the FORCLIM model in simulating forest dynamics and structure in the Pacific Northwest are discussed.

  11. The physical capabilities underlying timed "Up and Go" test are time-dependent in community-dwelling older women.

    PubMed

    Coelho-Junior, Hélio José; Rodrigues, Bruno; Gonçalves, Ivan de Oliveira; Asano, Ricardo Yukio; Uchida, Marco Carlos; Marzetti, Emanuele

    2018-04-01

    Timed 'Up and Go' (TUG) has been widely used in research and clinical practice to evaluate physical function and mobility in older adults. However, the physical capabilities underlying TUG performance are not well elucidated. Therefore, the present study aimed at investigating a selection of physical capacities underlying TUG performance in community-dwelling older women. Four hundred and sixty-eight apparently healthy older women independent to perform the activities of daily living (mean age: 65.8 ± 6.0 years) were recruited from two specialized healthcare centers for older adults to participate in the study. Volunteers had their medical books reviewed and underwent evaluations of anthropometric data as well as physical and functional capacities. Pearson's correlation results indicate that TUG performance was significantly associated with upper (i.e., handgrip strength) and lower (i.e., sit-to-stand) limb muscle strength, balance (i.e., one-leg stand), lower limb muscle power (i.e., countermovement jump), aerobic capacity (i.e., 6-minute walk test), and mobility (i.e., usual and maximal walking speeds). When the analyses were performed based on TUG quartiles, a larger number of physical capabilities were associated with TUG >75% in comparison with TUG <25%. Multiple linear regression results indicate that the variability in TUG (~20%) was explained by lower limb muscle strength (13%) and power (1%), balance (4%), mobility (2%), and aerobic capacity (<1%), even after adjusted by age and age plus body mass index (BMI). However, when TUG results were added as quartiles, a decrease in the impact of physical capacities on TUG performance was determined. As a whole, our findings indicate that the contribution of physical capabilities to TUG performance is altered according to the time taken to perform the test, so that older women in the lower quartiles - indicating a higher performance - have an important contribution of lower limb muscle strength, while volunteers in the highest quartile demonstrate a decreased dependence on lower limb muscle strength and an increased contribution of other physical capabilities, such as lower limb muscle power and balance. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Randomized controlled trial of web-based multimodal therapy for children with acquired brain injury to improve gross motor capacity and performance.

    PubMed

    Baque, Emmah; Barber, Lee; Sakzewski, Leanne; Boyd, Roslyn N

    2017-06-01

    To compare efficacy of a web-based multimodal training programme, 'Move it to improve it' (Mitii TM ), to usual care on gross motor capacity and performance for children with an acquired brain injury. Randomized waitlist controlled trial. Home environment. A total of 60 independently ambulant children (30 in each group), minimum 12 months post-acquired brain injury were recruited and randomly allocated to receive either 20 weeks of Mitii TM training (30 minutes/day, six days/week, total 60 hours) immediately, or waitlisted (usual care control group) for 20 weeks. A total of 58 children completed baseline assessments (32 males; age 11 years 11 months ± 2 years 6 months; Gross Motor Function Classification System equivalent I = 29, II = 29). The Mitii TM program comprised of gross motor, upper limb and visual perception/cognitive activities. The primary outcome was 30-second, repetition maximum functional strength tests for the lower limb (sit-to-stand, step-ups, half-kneel to stand). Secondary outcomes were the 6-minute walk test, High-level Mobility Assessment Tool, Timed Up and Go Test and habitual physical activity as captured by four-day accelerometry. Groups were equivalent at baseline on demographic and clinical measures. The Mitii TM group demonstrated significantly greater improvements on combined score of functional strength tests (mean difference 10.19 repetitions; 95% confidence interval, 3.26-17.11; p = 0.006) compared with the control group. There were no other between-group differences on secondary outcomes. Although the Mitii TM programme demonstrated statistically significant improvements in the functional strength tests of the lower limb, results did not exceed the minimum detectable change and cannot be considered clinically relevant for children with an acquired brain injury. Australian New Zealand Clinical Trials Registration Number, ANZCTR12613000403730.

  13. Motor performance in Prader-Willi syndrome patients and its potential influence on caregiver’s quality of life

    PubMed Central

    Chiu, Valeria Jia-Yi; Tsai, Li-Ping; Wei, Jang-Ting; Tzeng, I-Shiang

    2017-01-01

    Background Prader-Willi syndrome (PWS) is a complex, multisystem genetic disorder characterized by a variety of physical, cognitive, and behavioral impairments. PWS is a unique sarcopenia model characterized by an abnormal increase in body fat mass and a decrease in muscle mass that predisposes patients to reduced physical activity, functional limitations, and disability. These manifestations may require both symptomatic and supportive management, thus negatively influencing their lifelong family caregiver’s quality of life. The aim of this study was to examine the functional motor performance of adults with PWS in Taiwan and to measure the quality of life of their primary family caregivers. Methods The functional motor tests consisted of the following: (1) 30-s sit-to-stand test, (2) timed up-and-go test, (3) hand grip and lateral pinch strength tests, and (4) Berg Balance Scale. The World Health Organization Quality of Life-short form (WHOQOL-BREF) and the Short-Form 36 Health Survey Questionnaire (SF-36) were used to evaluate health-related quality of life, and the parenting stress index was used to assess the magnitude of stress within the parent-child system. Results The participants included seven adults (two females and five males) with genetically confirmed PWS and their respective main caregivers. The mean age of the adults with PWS was 25.28 years; range 18–31 years, SD 5.10; the mean BMI was 29.2 kg/m2, SD 6.43. All adults with PWS showed lower hand grip and lateral pinch strengths, fewer sit-to-stand cycles during the 30-s chair stand test, and greater average time during the timed up-and-go test when compared to the normative data on healthy adults. Balance was negatively correlated with the caregiver’s health concepts of social functioning (rs −0.879, P = 0.009) and with role limitations due to physical problems (rs −0.899, P = 0.006) and emotional problems (rs −0.794, P = 0.033); hand grip strength was negatively correlated with bodily pain (rs −0.800, P = 0.031), as assessed using the SF-36 questionnaire. The timed up-and-go test was positively correlated with the social relationship domain (rs 0.831, P = 0.021), as assessed using the WHOQOL-BREF questionnaire. The parenting stress index showed no association with the PWS patient’s physical activities. Conclusions All adults with PWS showed decreased upper and lower limb strength and functional mobility when compared to healthy adults. Some of their motor performance might have negative effects on their primary family members in terms of social participation and physical and emotional role limitations. Future research should explore the relationship between physical performances, psychological difficulties of PWS and caregiver’s QOL. PMID:29255649

  14. Effect of strength training on orthostatic hypotension in older adults.

    PubMed

    Brilla, L R; Stephens, A B; Knutzen, K M; Caine, D

    1998-01-01

    This preliminary study attempted to identify the frequency of orthostatic hypotension (OH) in community dwelling older adults who volunteered to participate in an 8-week, heavy-resistance, strength-training program. It also assessed the effect of the strength-training program on OH. From a larger study (n = 53) on high-resistance strength training in older adults (mean age 71.4 +/- 6.6 years), a subset of subjects (n = 24), mean age 71.0 +/- 5.8 years, was evaluated who met at least one criterion for OH. All subjects were tested for resting blood pressures (BP) and heart rates (HR) in the supine, sitting, and standing positions. Also noted was their response to orthostatism in rising from a cot after 10 minutes and rising from a chair after 5 minutes. The subset was not different from the overall group in gender ratio, age, or effect of medication on BP. The treatment was an 8-week strength-training program at 80% of their one repetition maximum. Significant changes (P < 0.05) were shown in supine diastolic BP (+3.2 mm Hg), sitting systolic BP (-3.9), and standing HR (+4.9 beats per minute). In response to the orthostatic challenge, significant (P < 0.05) improvements were shown in systolic BP (+9.7 mm Hg), diastolic BP (+4.7), and HR (+3.2 beats per minute) for the rise from chair, and in diastolic BP (+6.7 mm Hg) rise from the cot. These data show that OH is not uncommon (45%) in community dwelling older adults. A strength training program in older adults has little effect on resting BP, but elicits a positive adaptation to an orthostatic challenge.

  15. Validity and test–retest reliability of a novel simple back extensor muscle strength test

    PubMed Central

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    Objectives: To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Methods: Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations (r). Test–retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. Results: A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry (r = 0.824, p < 0.001). For the novel back extensor strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971–0.990), p < 0.001 and intraclass correlation coefficient = 0.901 (95% confidence interval, 0.833–0.943), p < 0.001, respectively). Limits of agreement for short-term repeated back extensor strength measures with the novel back extensor strength protocol were −6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density (p < 0.05) and 9% of lumbar spine index of bone structural strength (p < 0.05). Conclusion: Our novel hand-held dynamometer method to determine back extensor muscle strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site. PMID:28255442

  16. Psychological correlates of performance in female athletes during a 12-week off-season strength and conditioning program.

    PubMed

    Jones, Margaret T; Matthews, Tracey D; Murray, Mimi; Van Raalte, Judy; Jensen, Barbara E

    2010-03-01

    Examination of the relationship between performance testing and psychological measures before and after a 12-week strength and conditioning program was the study's purpose. Female NCAA Division-III soccer (n = 28), field hockey (n = 28), and softball (n = 19) athletes completed pre- and post-testing held 12 weeks apart. On day 1, athletes completed informed consent, 3 psychological measures (Profile of Mood States [POMS], Physical Self Perception Profile [PSPP], and Athlete's Self Perception of Physical Abilities [ASPPA]), and 2 strength tests (1 repetition maximum [1RM] bench, 1RM back squat). Day 2 consisted of the 30-yd sprint, pro agility run (PRO), vertical jump (VJ), and standing long jump (SLJ). All sports improved (p < 0.01) in 1RM bench and squat and reported increases in perceived Physical Strength on the PSPP (p < 0.01). Soccer athletes improved (p < 0.01) in VJ, SLJ, and PRO (p < 0.05). No differences were found in POMS scores. The POMS scores indicated that the athletes were not overtrained or experiencing staleness. A series of correlations showed relationships between physical and psychological measures. Specifically, Physical Strength was correlated with 1RM upper-body (r = 0.49, p < 0.01) and lower-body (r = 0.42, p < 0.01) strength. The PSPP Physical Strength was correlated with ASPPA ratings of upper-body (r = 0.68, p < 0.01) and lower-body (r = 0.57, p < 0.01) strength. The PSPP Sport Competence correlated with ASPPA ratings of power (r = 0.45, p < 0.01) and PRO (r = 0.38, p < 0.05). The study's results highlight the benefits of strength and conditioning. Furthermore, these results demonstrate how physical changes are related to athletes' physical self-perceptions and self-assessment of ability within their teams.

  17. Muscle strength and physical activity are associated with self-rated health in an adult Danish population.

    PubMed

    Hansen, Andreas W; Beyer, Nina; Flensborg-Madsen, Trine; Grønbæk, Morten; Helge, Jørn W

    2013-12-01

    To describe associations of muscle strength, physical activity and self-rated health. Isometric muscle strength by maximal handgrip strength (HGS) or muscle strength by 30s repeated chair stand test (30s-CS) was combined with leisure time physical activity. Using logistic regression odds ratio was calculated for good self-rated health according to the combined associations among 16,539 participants (59.7% women), mean age 51.9 (SD: 13.8) years, from a cross-sectional study in Denmark 2007-2008. Good self-rated health was positively associated with higher levels of physical activity and greater muscle strength. Regarding HGS the highest OR for good self-rated health was in the moderate/vigorous physically active participants with high HGS (OR=6.84, 95% CI: 4.85-9.65 and OR=7.34, 95% CI: 5.42-9.96 for men and women, respectively). Similarly the highest OR for good self-rated health was in the moderate/vigorous physically active participants with high scores in the 30s-CS test (6.06, 95% CI: 4.32-8.50 and 13.38, 95% CI: 9.59-18.67 for men and women, respectively). The reference groups were sedentary participants with low strength (HGS or 30s-CS). The combined score for physical activity level with either HGS or 30s-CS was strongly positively associated with self-related health. © 2013.

  18. Fitness as a determinant of arterial stiffness in healthy adult men: a cross-sectional study.

    PubMed

    Chung, Jinwook; Kim, Milyang; Jin, Youngsoo; Kim, Yonghwan; Hong, Jeeyoung

    2018-01-01

    Fitness is known to influence arterial stiffness. This study aimed to assess differences in cardiorespiratory endurance, muscular strength, and flexibility according to arterial stiffness, based on sex and age. We enrolled 1590 healthy adults (men: 1242, women: 348) who were free of metabolic syndrome. We measured cardiorespiratory endurance in an exercise stress test on a treadmill, muscular strength by a grip test, and flexibility by upper body forward-bends from a standing position. The brachial-ankle pulse wave velocity test was performed to measure arterial stiffness before the fitness test. Cluster analysis was performed to divide the patients into groups with low (Cluster 1) and high (Cluster 2) arterial stiffness. According to the k-cluster analysis results, Cluster 1 included 624 men and 180 women, and Cluster 2 included 618 men and 168 women. Men in the middle-aged group with low arterial stiffness demonstrated higher cardiorespiratory endurance, muscular strength, and flexibility than those with high arterial stiffness. Similarly, among men in the old-aged group, the cardiorespiratory endurance and muscular strength, but not flexibility, differed significantly according to arterial stiffness. Women in both clusters showed similar cardiorespiratory endurance, muscular strength, and flexibility regardless of their arterial stiffness. Among healthy adults, arterial stiffness was inversely associated with fitness in men but not in women. Therefore, fitness seems to be a determinant for arterial stiffness in men. Additionally, regular exercise should be recommended for middle-aged men to prevent arterial stiffness.

  19. Correlation of Menopausal Symptoms and Quality of Life with Physical Performance in Middle-Aged Women.

    PubMed

    Silva, Rívea Trindade da; Câmara, Saionara Maria Aires da; Moreira, Mayle Andrade; Nascimento, Rafaela Andrade do; Vieira, Mariana Carmem Apolinário; Morais, Maria Socorro Medeiros de; Maciel, Álvaro Campos Cavalcanti

    2016-06-01

    Introduction Some studies have investigated the influence of hormonal deficits and menopausal status in muscle disorders of women. However, it has not been investigated the relationship of both climacteric symptoms and the perception of quality of life with physical performance. Objective To evaluate the correlation of menopausal symptoms and quality of life with physical performance in middle-aged women. Methods This cross-sectional study was performed from April to November 2013 in the municipality of Parnamirim, in the Brazilian state, Rio Grande do Norte. The sample was composed of 497 women aged 40-65 years. The Menopause Rating Scale (MRS) and the Utian Quality of Life (UQOL) questionnaire were used to evaluate menopausal symptoms and quality of life respectively. Measures of physical performance included handgrip strength, knee extensor and flexor strengths (using an isometric dynamometer), gait speed, and chair stand test. The correlation between menopausal symptoms and quality of life with physical performance was assessed by Pearson's correlation coefficient with significance set at p < 0.05 and a confidence interval of 95%. Results There was a significant negative correlation between handgrip strength and somatic MRS score (p = 0.002) and total MRS score (p = 0.03). There was a significant correlation between knee flexor strength and sit-to-stand time and all menopausal symptom areas (p < 0.05), except psychological symptoms. There was a positive correlation between physical performance of the knee flexors and quality of life items including occupational (p = 0.001), emotional (p = 0.005), and total UQOL (p = 0.01), but a negative correlation with sit-to-stand time and all quality of life domains (p < 0.05). Conclusion A greater intensity of menopausal symptoms and worse quality of life were related with worse physical performance. Thus, preventive measures should be implemented to avoid adverse effects on physical performance at more advanced ages. Thieme Publicações Ltda Rio de Janeiro, Brazil.

  20. Root strength of tropical plants - An investigation in the Western Ghats of Kerala, India

    NASA Astrophysics Data System (ADS)

    Lukose Kuriakose, S.; van Beek, L. P. H.; van Westen, C. J.

    2009-04-01

    Earlier research on debris flows in the Tikovil River basin of the Western Ghats concluded that root cohesion is significant in maintaining the overall stability of the region. In this paper we present the most recent results (December 2008) of root tensile strength tests conducted on nine species of plants that are commonly found in the region. They are 1) Rubber (Hevea Brasiliensis), 2) Coconut Palm (Cocos nucifera), 3) Jackfruit trees (Artocarpus heterophyllus), 4) Teak (Tectona grandis), 5) Mango trees (Mangifera indica), 6) Lemon grass (Cymbopogon citratus), 7) A variety of Tamarind (Garcinia gummigutta), 8) Coffee (Coffea Arabica) and Tea (Camellia sinensis). About 1500 samples were collected of which only 380 could be tested (in the laboratory) due to breakage of roots during the tests. In the successful tests roots failed in tension. Roots having diameters between 2 mm and 12 mm were tested. Each sample tested has a length of 15 cm. Results indicate that the roots of Coffee, Tamarind, Lemon grass and Jackfruit are the strongest of the nine plant types tested whereas Tea and Teak plants had the most fragile roots. Coconut roots behaved atypical to the others, as the bark of the roots was crushed and slipped from the clamp when tested whereas its internal fiber was the strongest of all tested. Root tensile strength decreases with increasing diameters, Rubber showing more ductile behaviour than Coffee and Tamarind that behaved more brittle, root tensile strength increasing exponentially for finer roots. Teak and Tea showed almost a constant root tensile strength over the range of diameters tested and little variability. Jack fruit and mango trees showed the largest variability, which may be explained by the presence of root nodules, preventing the derivation of an unequivocal relationship between root diameters and tensile strength. This results in uncertainty of root strength estimates that are applicable. These results provide important information to quantify the upper limit of the root cohesion at the stand level in combination with land use maps. This is an indispensable component in the evaluation of slope stability in the region.

  1. Association of Physical Performance and Pain With Fear of Falling Among Community—Dwelling Japanese Women Aged 65 Years and Older

    PubMed Central

    Tomita, Yoshihito; Arima, Kazuhiko; Kanagae, Mitsuo; Okabe, Takuhiro; Mizukami, Satoshi; Nishimura, Takayuki; Abe, Yasuyo; Goto, Hisashi; Horiguchi, Itsuko; Aoyagi, Kiyoshi

    2015-01-01

    Abstract Our aim was to explore the association of physical performance and pain with fear of falling among community-dwelling Japanese women. The subjects were 278 women aged 65 years and over. We collected information on fear of falling, painful joints, comorbidities, falls in the previous year, and cataracts. Walking time (distance of 6 m), chair stand time (5 times), grip strength, the timed up and go test (TUG), and functional reach were measured. The prevalence of fear of falling was 36.3%, and it increased with age, but it was not significant (P = 0.081). Multivariate logistic regression analysis showed that poor physical performance (longer walking time, longer chair stand time, weaker grip strength, and longer TUG) and pain (low back, and upper and lower extremity pain) were significantly associated with fear of falling after adjusting for age, body mass index, comorbidities, falls in the previous year, and cataracts. Maintaining physical functioning and managing pain may be important for elderly women with fear of falling. PMID:26334906

  2. Association of Physical Performance and Pain With Fear of Falling Among Community-Dwelling Japanese Women Aged 65 Years and Older.

    PubMed

    Tomita, Yoshihito; Arima, Kazuhiko; Kanagae, Mitsuo; Okabe, Takuhiro; Mizukami, Satoshi; Nishimura, Takayuki; Abe, Yasuyo; Goto, Hisashi; Horiguchi, Itsuko; Aoyagi, Kiyoshi

    2015-09-01

    Our aim was to explore the association of physical performance and pain with fear of falling among community-dwelling Japanese women.The subjects were 278 women aged 65 years and over. We collected information on fear of falling, painful joints, comorbidities, falls in the previous year, and cataracts. Walking time (distance of 6 m), chair stand time (5 times), grip strength, the timed up and go test (TUG), and functional reach were measured.The prevalence of fear of falling was 36.3%, and it increased with age, but it was not significant (P = 0.081). Multivariate logistic regression analysis showed that poor physical performance (longer walking time, longer chair stand time, weaker grip strength, and longer TUG) and pain (low back, and upper and lower extremity pain) were significantly associated with fear of falling after adjusting for age, body mass index, comorbidities, falls in the previous year, and cataracts.Maintaining physical functioning and managing pain may be important for elderly women with fear of falling.

  3. Identification of the Parameters of Menétrey -Willam Failure Surface of Calcium Silicate Units

    NASA Astrophysics Data System (ADS)

    Radosław, Jasiński

    2017-10-01

    The identification of parameters of Menétrey-Willamsurface made of concrete, masonry or autoclaved aerated concrete is not complicated. It is much more difficult to identify failure parameters of masonry units with cavities. This paper describes the concept of identifying the parameters of Menétrey-Willam failure surface (M-W-3) with reference to masonry units with vertical cavities. The M-W-3 surface is defined by uniaxial compressive strength fc, uniaxial tensile strength ft and eccentricity of elliptical function e. A test stand was built to identify surface parameters. It was used to test behaviour of masonry units under triaxial stress and conduct tests on whole masonry units in the uniaxial state. Results from tests on tens of silicate masonry units are presented in the Haigh-Westergaard (H-W) space. Statistical analyses were used to identify the shape of surface meridian, and then to determine eccentricity of the elliptical function.

  4. The study of fix composite panel and steel plates on testing stand

    NASA Astrophysics Data System (ADS)

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  5. Performance-Based Measures Associate With Frailty in Patients With End-Stage Liver Disease.

    PubMed

    Lai, Jennifer C; Volk, Michael L; Strasburg, Debra; Alexander, Neil

    2016-12-01

    Physical frailty, as measured by the Fried Frailty Index, is increasingly recognized as a critical determinant of outcomes in patients with cirrhosis. However, its utility is limited by the inclusion of self-reported components. We aimed to identify performance-based measures associated with frailty in patients with cirrhosis. Patients with cirrhosis, aged 50 years or older, underwent: 6-minute walk test (cardiopulmonary endurance), chair stands in 30 seconds (muscle endurance), isometric knee extension (lower extremity strength), unipedal stance time (static balance), and maximal step length (dynamic balance/coordination). Linear regression associated each physical performance test with frailty. Principal components exploratory factor analysis evaluated the interrelatedness of frailty and the 5 physical performance tests. Of 40 patients with cirrhosis, with a median age of 64 years and Model for End-stage Liver Disease (MELD) MELD of 12.10 (25%) were frail by Fried Frailty Index ≥3. Frail patients with cirrhosis had poorer performance in 6-minute walk test distance (231 vs 338 m), 30-second chair stands (7 vs 10), isometric knee extension (86 vs 122 Newton meters), and maximal step length (22 vs 27 in. (P ≤ 0.02 for each). Each physical performance test was significantly associated with frailty (P < 0.01), even after adjustment for MELD or hepatic encephalopathy. Principal component factor analysis demonstrated substantial, but unique, clustering of each physical performance test to a single factor-frailty. Frailty in cirrhosis is a multidimensional construct that is distinct from liver dysfunction and incorporates endurance, strength, and balance. Our data provide specific targets for prehabilitation interventions aimed at reducing frailty in patients with cirrhosis in preparation for liver transplantation.

  6. Association between Physical Fitness and Successful Aging in Taiwanese Older Adults.

    PubMed

    Lin, Pay-Shin; Hsieh, Chih-Chin; Cheng, Huey-Shinn; Tseng, Tsai-Jou; Su, Shin-Chang

    2016-01-01

    Population aging is escalating in numerous countries worldwide; among them is Taiwan, which will soon become an aged society. Thus, aging successfully is an increasing concern. One of the factors for achieving successful aging (SA) is maintaining high physical function. The purpose of this study was to determine the physical fitness factors associated with SA in Taiwanese older adults (OAs), because these factors are intervenable. Community-dwelling OAs aged more than 65 years and residing in Northern Taiwan were recruited in this study. They received a comprehensive geriatric assessment, which includes sociodemographic data, health conditions and behaviors, activities of daily living (ADL) and instrumental ADL (IADL) function, cognitive and depressive status, and quality of life. Physical fitness tests included the grip strength (GS), 30-second sit-to-stand (30s STS), timed up-and-go (TUG), functional reach (FR), one-leg standing, chair sit-and-reach, and reaction time (drop ruler) tests as well as the 6-minute walk test (6MWT). SA status was defined as follows: complete independence in performing ADL and IADL, satisfactory cognitive status (Mini-Mental State Examination ≥ 24), no depression (Geriatric Depression Scale < 5), and favorable social function (SF subscale ≥ 80 in SF-36). Adjusted multiple logistic regression analyses were performed. Among the total recruited OAs (n = 378), 100 (26.5%) met the aforementioned SA criteria. After adjustment for sociodemographic characteristics and health condition and behaviors, some physical fitness tests, namely GS, 30s STS, 6MWT, TUG, and FR tests, were significantly associated with SA individually, but not in the multivariate model. Among the physical fitness variables tested, cardiopulmonary endurance, mobility, muscle strength, and balance were significantly associated with SA in Taiwanese OAs. Early detection of deterioration in the identified functions and corresponding intervention is essential to ensuring SA.

  7. Association between Physical Fitness and Successful Aging in Taiwanese Older Adults

    PubMed Central

    Cheng, Huey-Shinn; Tseng, Tsai-Jou; Su, Shin-Chang

    2016-01-01

    Population aging is escalating in numerous countries worldwide; among them is Taiwan, which will soon become an aged society. Thus, aging successfully is an increasing concern. One of the factors for achieving successful aging (SA) is maintaining high physical function. The purpose of this study was to determine the physical fitness factors associated with SA in Taiwanese older adults (OAs), because these factors are intervenable. Community-dwelling OAs aged more than 65 years and residing in Northern Taiwan were recruited in this study. They received a comprehensive geriatric assessment, which includes sociodemographic data, health conditions and behaviors, activities of daily living (ADL) and instrumental ADL (IADL) function, cognitive and depressive status, and quality of life. Physical fitness tests included the grip strength (GS), 30-second sit-to-stand (30s STS), timed up-and-go (TUG), functional reach (FR), one-leg standing, chair sit-and-reach, and reaction time (drop ruler) tests as well as the 6-minute walk test (6MWT). SA status was defined as follows: complete independence in performing ADL and IADL, satisfactory cognitive status (Mini-Mental State Examination ≥ 24), no depression (Geriatric Depression Scale < 5), and favorable social function (SF subscale ≥ 80 in SF-36). Adjusted multiple logistic regression analyses were performed. Among the total recruited OAs (n = 378), 100 (26.5%) met the aforementioned SA criteria. After adjustment for sociodemographic characteristics and health condition and behaviors, some physical fitness tests, namely GS, 30s STS, 6MWT, TUG, and FR tests, were significantly associated with SA individually, but not in the multivariate model. Among the physical fitness variables tested, cardiopulmonary endurance, mobility, muscle strength, and balance were significantly associated with SA in Taiwanese OAs. Early detection of deterioration in the identified functions and corresponding intervention is essential to ensuring SA. PMID:26963614

  8. Associations of Walking Speed, Grip Strength, and Standing Balance With Total and Cause-Specific Mortality in a General Population of Japanese Elders.

    PubMed

    Nofuji, Yu; Shinkai, Shoji; Taniguchi, Yu; Amano, Hidenori; Nishi, Mariko; Murayama, Hiroshi; Fujiwara, Yoshinori; Suzuki, Takao

    2016-02-01

    Walking speed, grip strength, and standing balance are key components of physical performance in older people. The present study aimed to evaluate (1) associations of these physical performance measures with cause-specific mortality, (2) independent associations of individual physical performance measures with mortality, and (3) the added value of combined use of the 3 physical performance measures in predicting all-cause and cause-specific mortality. Prospective cohort study with a follow-up of 10.5 years. Tokyo Metropolitan Institute of Gerontology Longitudinal Interdisciplinary Study on Aging (TMIG-LISA), Japan. A total of 1085 initially nondisabled older Japanese aged 65 to 89 years. Usual walking speed, grip strength, and standing balance were measured at baseline survey. During follow-up, 324 deaths occurred (122 of cardiovascular disease, 75 of cancer, 115 of other causes, and 12 of unknown causes). All 3 physical performance measures were significantly associated with all-cause, cardiovascular, and other-cause mortality, but not with cancer mortality, independent of potential confounders. When all 3 physical performance measures were simultaneously entered into the model, each was significantly independently associated with all-cause and cardiovascular mortality. The C statistics for all-cause and cardiovascular mortality were significantly increased by adding grip strength and standing balance to walking speed (P < .01), and the net reclassification improvement for them was estimated at 18.7% and 7.5%, respectively. Slow walking speed, weak grip strength, and poor standing balance predicted all-cause, cardiovascular, and other-cause mortality, but not cancer mortality, independent of covariates. Moreover, these 3 components of physical performance were independently associated with all-cause and cardiovascular mortality and their combined use increased prognostic power. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  9. Occupational Physical Activity Habits of UK Office Workers: Cross-Sectional Data from the Active Buildings Study.

    PubMed

    Smith, Lee; Sawyer, Alexia; Gardner, Benjamin; Seppala, Katri; Ucci, Marcella; Marmot, Alexi; Lally, Pippa; Fisher, Abi

    2018-06-09

    Habitual behaviours are learned responses that are triggered automatically by associated environmental cues. The unvarying nature of most workplace settings makes workplace physical activity a prime candidate for a habitual behaviour, yet the role of habit strength in occupational physical activity has not been investigated. Aims of the present study were to: (i) document occupational physical activity habit strength; and (ii) investigate associations between occupational activity habit strength and occupational physical activity levels. A sample of UK office-based workers ( n = 116; 53% female, median age 40 years, SD 10.52) was fitted with activPAL accelerometers worn for 24 h on five consecutive days, providing an objective measure of occupational step counts, stepping time, sitting time, standing time and sit-to-stand transitions. A self-report index measured the automaticity of two occupational physical activities (“being active” (e.g., walking to printers and coffee machines) and “stair climbing”). Adjusted linear regression models investigated the association between occupational activity habit strength and objectively-measured occupational step counts, stepping time, sitting time, standing time and sit-to-stand transitions. Eighty-one per cent of the sample reported habits for “being active”, and 62% reported habits for “stair climbing”. In adjusted models, reported habit strength for “being active” were positively associated with average occupational sit-to-stand transitions per hour (B = 0.340, 95% CI: 0.053 to 0.627, p = 0.021). “Stair climbing” habit strength was unexpectedly negatively associated with average hourly stepping time (B = −0.01, 95% CI: −0.01 to −0.00, p = 0.006) and average hourly occupational step count (B = −38.34, 95% CI: −72.81 to −3.88, p = 0.030), which may reflect that people with stronger stair-climbing habits compensate by walking fewer steps overall. Results suggest that stair-climbing and office-based occupational activity can be habitual. Interventions might fruitfully promote habitual workplace activity, although, in light of potential compensation effects, such interventions should perhaps focus on promoting moderate-intensity activity.

  10. Anthropometric and physiological profiles of active blind Malaysian males.

    PubMed

    Singh, R; Singh, H J

    1993-12-01

    Cardiopulmonary capacities of twelve adults (aged between 14 to 44 years) with varying degrees of blindness engaged in regular recreational activities were compared with twelve age-matched normal sighted healthy males (control group) who were also involved in regular recreational activities. Maximum oxygen consumption (VO2max) was measured directly during exhaustive exercise test on a cycle ergometer. Forced vital capacity, leg strength and power were determined by spirometry, standing long jump and vertical jump respectively. No significant differences in VO2max, forced vital capacity and leg strength and power were observed between the blind and the control groups. No anthropometric differences were evident between the two groups. The results show therefore that the visually handicapped who are active can have a similar level of physical fitness, lung function and explosive leg strength as those of their active sighted counterparts.

  11. Weld Metallurgy and Mechanical Properties of High Manganese Ultra-high Strength Steel Dissimilar Welds

    NASA Astrophysics Data System (ADS)

    Dahmen, Martin; Lindner, Stefan; Monfort, Damien; Petring, Dirk

    The increasing demand for ultra-high strength steels in vehicle manufacturing leads to the application of new alloys. This poses a challenge on joining especially by fusion welding. A stainless high manganese steel sheet with excellent strength and deformation properties stands in the centre of the development. Similar and dissimilar welds with a metastable austenitic steel and a hot formed martensitic stainless steel were performed. An investigation of the mixing effects on the local microstructure and the hardness delivers the metallurgical features of the welds. Despite of carbon contents above 0.4 wt.% none of the welds have shown cracks. Mechanical properties drawn from tensile tests deliver high breaking forces enabling a high stiffness of the joints. The results show the potential for the application of laser beam welding for joining in assembly of structural parts.

  12. Influence of physical fitness on cardio-metabolic risk factors in European children. The IDEFICS study.

    PubMed

    Zaqout, M; Michels, N; Bammann, K; Ahrens, W; Sprengeler, O; Molnar, D; Hadjigeorgiou, C; Eiben, G; Konstabel, K; Russo, P; Jiménez-Pavón, D; Moreno, L A; De Henauw, S

    2016-07-01

    The aim of the study was to assess the associations of individual and combined physical fitness components with single and clustering of cardio-metabolic risk factors in children. This 2-year longitudinal study included a total of 1635 European children aged 6-11 years. The test battery included cardio-respiratory fitness (20-m shuttle run test), upper-limb strength (handgrip test), lower-limb strength (standing long jump test), balance (flamingo test), flexibility (back-saver sit-and-reach) and speed (40-m sprint test). Metabolic risk was assessed through z-score standardization using four components: waist circumference, blood pressure (systolic and diastolic), blood lipids (triglycerides and high-density lipoprotein) and insulin resistance (homeostasis model assessment). Mixed model regression analyses were adjusted for sex, age, parental education, sugar and fat intake, and body mass index. Physical fitness was inversely associated with clustered metabolic risk (P<0.001). All coefficients showed a higher clustered metabolic risk with lower physical fitness, except for upper-limb strength (β=0.057; P=0.002) where the opposite association was found. Cardio-respiratory fitness (β=-0.124; P<0.001) and lower-limb strength (β=-0.076; P=0.002) were the most important longitudinal determinants. The effects of cardio-respiratory fitness were even independent of the amount of vigorous-to-moderate activity (β=-0.059; P=0.029). Among all the metabolic risk components, blood pressure seemed not well predicted by physical fitness, while waist circumference, blood lipids and insulin resistance all seemed significantly predicted by physical fitness. Poor physical fitness in children is associated with the development of cardio-metabolic risk factors. Based on our results, this risk might be modified by improving mainly cardio-respiratory fitness and lower-limb muscular strength.

  13. Sitting and standing postures are corrected by adjustable furniture with lowered muscle tension in high-school students.

    PubMed

    Koskelo, R; Vuorikari, K; Hänninen, O

    2007-10-01

    This study compared the effect of 24 months of adjustable school desks and chairs usage (the intervention) and traditional non-adjustable usage (the control condition) on sitting and standing postures, muscle strength, classroom muscle tension, pain and learning in 15 (8 female and 7 male) high-school students and 15 anthropometrically and gender matched control students from neighbouring schools. It was assessed whether any responses took place after growth cessation. In comparison with controls, the intervention group of students' sitting postures standing kyphosis, scoliosis and lordosis became significantly better, both before and after growth cessation. Trunk muscle strength increased in the intervention students whose muscle tension during classes fell significantly in the trapezius and lumbar muscles, whereas in control students' lumbar tension increased. Headache and low-back pain correlated with neck-shoulder pain and trapezius muscle tension. Intervention students reported that they experienced benefits from the adjustable tables and chairs. They also received significantly better overall marks than the controls at the end of high school. It is concluded that the adjustable school desks and chairs promoted better sitting and standing postures, increased muscle strength, alleviated pain and appeared to be associated with better overall academic marks.

  14. Evaluation of a Low-Noise Formate Spiral-Bevel Gear Set

    NASA Technical Reports Server (NTRS)

    Lewicki, David g.; Woods, Ron L.; Litvin, Faydor L.; Fuentes, Alfonso

    2007-01-01

    Studies to evaluate low-noise Formate spiral-bevel gears were performed. Experimental tests were performed on the OH-58D helicopter main-rotor transmission in the NASA Glenn 500-hp Helicopter Transmission Test Stand. Low-noise Formate spiral-bevel gears were compared to the baseline OH-58D spiral-bevel gear design, a high-strength design, and previously tested low-noise designs (including an original low-noise design and an improved-bearing-contact low-noise design). Noise, vibration, and tooth strain tests were performed. The Formate design showed a decrease in noise and vibration compared to the baseline OH-58D design, and was similar to that of the previously tested improved-bearing contact low-noise design. The pinion tooth stresses for the Formate design significantly decreased in comparison to the baseline OH-58D design. Also similar to that of the improved bearing-contact low-noise design, the maximum stresses of the Formate design shifted toward the heel, compared to the center of the face width for the baseline, high-strength, and previously tested low-noise designs.

  15. A SIMPLE FRAILTY QUESTIONNAIRE (FRAIL) PREDICTS OUTCOMES IN MIDDLE AGED AFRICAN AMERICANS

    PubMed Central

    MORLEY, J.E.; MALMSTROM, T.K.; MILLER, D.K.

    2015-01-01

    Objective To validate the FRAIL scale. Design Longitudinal study. Setting Community. Participants Representative sample of African Americans age 49 to 65 years at onset of study. Measurements The 5-item FRAIL scale (Fatigue, Resistance, Ambulation, Illnesses, & Loss of Weight), at baseline and activities of daily living (ADLs), instrumental activities of daily living (IADLs), mortality, short physical performance battery (SPPB), gait speed, one-leg stand, grip strength and injurious falls at baseline and 9 years. Blood tests for CRP, SIL6R, STNFR1, STNFR2 and 25 (OH) vitamin D at baseline. Results Cross-sectionally the FRAIL scale correlated significantly with IADL difficulties, SPPB, grip strength and one-leg stand among participants with no baseline ADL difficulties (N=703) and those outcomes plus gait speed in those with no baseline ADL dependencies (N=883). TNFR1 was increased in pre-frail and frail subjects and CRP in some subgroups. Longitudinally (N=423 with no baseline ADL difficulties or N=528 with no baseline ADL dependencies), and adjusted for the baseline value for each outcome, being pre-frail at baseline significantly predicted future ADL difficulties, worse one-leg stand scores, and mortality in both groups, plus IADL difficulties in the dependence-excluded group. Being frail at baseline significantly predicted future ADL difficulties, IADL difficulties, and mortality in both groups, plus worse SPPB in the dependence-excluded group. Conclusion This study has validated the FRAIL scale in a late middle-aged African American population. This simple 5-question scale is an excellent screening test for clinicians to identify frail persons at risk of developing disability as well as decline in health functioning and mortality. PMID:22836700

  16. Effects of a Supervised versus an Unsupervised Combined Balance and Strength Training Program on Balance and Muscle Power in Healthy Older Adults: A Randomized Controlled Trial.

    PubMed

    Lacroix, André; Kressig, Reto W; Muehlbauer, Thomas; Gschwind, Yves J; Pfenninger, Barbara; Bruegger, Othmar; Granacher, Urs

    2016-01-01

    Losses in lower extremity muscle strength/power, muscle mass and deficits in static and particularly dynamic balance due to aging are associated with impaired functional performance and an increased fall risk. It has been shown that the combination of balance and strength training (BST) mitigates these age-related deficits. However, it is unresolved whether supervised versus unsupervised BST is equally effective in improving muscle power and balance in older adults. This study examined the impact of a 12-week BST program followed by 12 weeks of detraining on measures of balance and muscle power in healthy older adults enrolled in supervised (SUP) or unsupervised (UNSUP) training. Sixty-six older adults (men: 25, women: 41; age 73 ± 4 years) were randomly assigned to a SUP group (2/week supervised training, 1/week unsupervised training; n = 22), an UNSUP group (3/week unsupervised training; n = 22) or a passive control group (CON; n = 22). Static (i.e., Romberg Test) and dynamic (i.e., 10-meter walk test) steady-state, proactive (i.e., Timed Up and Go Test, Functional Reach Test), and reactive balance (e.g., Push and Release Test), as well as lower extremity muscle power (i.e., Chair Stand Test; Stair Ascent and Descent Test) were tested before and after the active training phase as well as after detraining. Adherence rates to training were 92% for SUP and 97% for UNSUP. BST resulted in significant group × time interactions. Post hoc analyses showed, among others, significant training-related improvements for the Romberg Test, stride velocity, Timed Up and Go Test, and Chair Stand Test in favor of the SUP group. Following detraining, significantly enhanced performances (compared to baseline) were still present in 13 variables for the SUP group and in 10 variables for the UNSUP group. Twelve weeks of BST proved to be safe (no training-related injuries) and feasible (high attendance rates of >90%). Deficits of balance and lower extremity muscle power can be mitigated by BST in healthy older adults. Additionally, supervised as compared to unsupervised BST was more effective. Thus, it is recommended to counteract intrinsic fall risk factors by applying supervised BST programs for older adults. © 2015 The Author(s) Published by S. Karger AG, Basel.

  17. [Electrical acupoint stimulation increases athletes' rapid strength].

    PubMed

    Yang, Hua-yuan; Liu, Tang-yi; Kuai, Le; Gao, Ming

    2006-05-01

    To search for a stimulation method for increasing athletes' performance. One hundred and fifty athletes were randomly divided into a trial group and a control group, 75 athletes in each group. Acupoints were stimulated with audio frequency pulse modulated wave and multi-blind method were used to investigate effects of the electric stimulation of acupoints on 30-meter running, standing long jumping and Cybex isokinetic testing index. The acupoint electric stimulation method could significantly increase athlete's performance (P < 0.05), and the biomechanical indexes, maximal peak moment of force (P < 0.05), force moment accelerating energy (P < 0.05) and average power (P < 0.05). Electrical acupoint stimulation can enhance athlete's rapid strength.

  18. Clinical history and biologic age predicted falls better than objective functional tests.

    PubMed

    Gerdhem, Paul; Ringsberg, Karin A M; Akesson, Kristina; Obrant, Karl J

    2005-03-01

    Fall risk assessment is important because the consequences, such as a fracture, may be devastating. The objective of this study was to find the test or tests that best predicted falls in a population-based sample of elderly women. The fall-predictive ability of a questionnaire, a subjective estimate of biologic age and objective functional tests (gait, balance [Romberg and sway test], thigh muscle strength, and visual acuity) were compared in 984 randomly selected women, all 75 years of age. A recalled fall was the most important predictor for future falls. Only recalled falls and intake of psycho-active drugs independently predicted future falls. Women with at least five of the most important fall predictors (previous falls, conditions affecting the balance, tendency to fall, intake of psychoactive medication, inability to stand on one leg, high biologic age) had an odds ratio of 11.27 (95% confidence interval 4.61-27.60) for a fall (sensitivity 70%, specificity 79%). The more time-consuming objective functional tests were of limited importance for fall prediction. A simple clinical history, the inability to stand on one leg, and a subjective estimate of biologic age were more important as part of the fall risk assessment.

  19. Greater association of peak neuromuscular performance with cortical bone geometry, bone mass and bone strength than bone density: A study in 417 older women.

    PubMed

    Belavý, Daniel L; Armbrecht, Gabriele; Blenk, Tilo; Bock, Oliver; Börst, Hendrikje; Kocakaya, Emine; Luhn, Franziska; Rantalainen, Timo; Rawer, Rainer; Tomasius, Frederike; Willnecker, Johannes; Felsenberg, Dieter

    2016-02-01

    We evaluated which aspects of neuromuscular performance are associated with bone mass, density, strength and geometry. 417 women aged 60-94years were examined. Countermovement jump, sit-to-stand test, grip strength, forearm and calf muscle cross-sectional area, areal bone mineral content and density (aBMC and aBMD) at the hip and lumbar spine via dual X-ray absorptiometry, and measures of volumetric vBMC and vBMD, bone geometry and section modulus at 4% and 66% of radius length and 4%, 38% and 66% of tibia length via peripheral quantitative computed tomography were performed. The first principal component of the neuromuscular variables was calculated to generate a summary neuromuscular variable. Percentage of total variance in bone parameters explained by the neuromuscular parameters was calculated. Step-wise regression was also performed. At all pQCT bone sites (radius, ulna, tibia, fibula), a greater percentage of total variance in measures of bone mass, cortical geometry and/or bone strength was explained by peak neuromuscular performance than for vBMD. Sit-to-stand performance did not relate strongly to bone parameters. No obvious differential in the explanatory power of neuromuscular performance was seen for DXA aBMC versus aBMD. In step-wise regression, bone mass, cortical morphology, and/or strength remained significant in relation to the first principal component of the neuromuscular variables. In no case was vBMD positively related to neuromuscular performance in the final step-wise regression models. Peak neuromuscular performance has a stronger relationship with leg and forearm bone mass and cortical geometry as well as proximal forearm section modulus than with vBMD. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Efficacy and feasibility of a novel tri-modal robust exercise prescription in a retirement community: a randomized, controlled trial.

    PubMed

    Baker, Michael K; Kennedy, David J; Bohle, Philip L; Campbell, Deena S; Knapman, Leona; Grady, Jodie; Wiltshire, James; McNamara, Maria; Evans, William J; Atlantis, Evan; Fiatarone Singh, Maria A

    2007-01-01

    To test the feasibility and efficacy of current guidelines for multimodal exercise programs in older adults. Randomized, controlled trial. Retirement village. Thirty-eight subjects (14 men and 24 women) aged 76.6 +/- 6.1. A wait list control or 10 weeks of supervised exercise consisting of high-intensity (80% of one-repetition maximum (1RM)) progressive resistance training (PRT) 3 days per week, moderate-intensity (rating of perceived exertion 11 to 14/20) aerobic training 2 days per week, and progressive balance training 1 day per week. Blinded assessments of dynamic muscle strength (1RM), balance, 6-minute walk, gait velocity, chair stand, stair climb, depressive symptoms, self-efficacy, and habitual physical activity level. Higher baseline strength and psychological well-being were associated with better functional performance. Strength gains over 10 weeks averaged 39+/-31% in exercise, versus 21+/-24% in controls (P=.10), with greater improvements in hip flexion (P=.01), hip abduction (P=.02), and chest press (P=.04) in the exercise group. Strength adaptations were greatest in exercises in which the intended continuous progressive overload was achieved. Stair climb power (12.3+/-15%, P=.002) and chair stand time (-7.1+/-15%, P=.006) improved significantly and similarly in both groups. Reduction in depressive symptoms was significantly related to compliance (attendance rate r=-0.568, P=.009, PRT progression in loading r=-0.587, P=.02, and total volume of aerobic training r=-0.541, P=.01), as well as improvements in muscle strength (r=-0.498, P=.002). Robust physical and psychological adaptations to exercise are linked, although volumes and intensities of multiple exercise modalities sufficient to cause significant adaptation appear difficult to prescribe and adhere to simultaneously in older adults.

  1. Low dynamic muscle strength and its associations with fatigue, functional performance, and quality of life in premenopausal patients with systemic lupus erythematosus and low disease activity: a case–control study

    PubMed Central

    2013-01-01

    Background The purpose of the present study was to compare dynamic muscle strength, functional performance, fatigue, and quality of life in premenopausal systemic lupus erythematosus (SLE) patients with low disease activity versus matched-healthy controls and to determine the association of dynamic muscle strength with fatigue, functional performance, and quality of life in SLE patients. Methods We evaluated premenopausal (18–45 years) SLE patients with low disease activity (Systemic lupus erythematosus disease activity index [SLEDAI]: mean 1.5 ± 1.2). The control (n = 25) and patient (n = 25) groups were matched by age, physical characteristics, and the level of physical activities in daily life (International Physical Activity Questionnaire IPAQ). Both groups had not participated in regular exercise programs for at least six months prior to the study. Dynamic muscle strength was assessed by one-repetition maximum (1-RM) tests. Functional performance was assessed by the Timed Up and Go (TUG), in 30-s test a chair stand and arm curl using a 2-kg dumbbell and balance test, handgrip strength and a sit-and-reach flexibility test. Quality of life (SF-36) and fatigue were also measured. Results The SLE patients showed significantly lower dynamic muscle strength in all exercises (leg press 25.63%, leg extension 11.19%, leg curl 15.71%, chest press 18.33%, lat pulldown 13.56%, 1-RM total load 18.12%, P < 0.001-0.02) compared to the controls. The SLE patients also had lower functional performance, greater fatigue and poorer quality of life. In addition, fatigue, SF-36 and functional performance accounted for 52% of the variance in dynamic muscle strength in the SLE patients. Conclusions Premenopausal SLE patients with low disease activity showed lower dynamic muscle strength, along with increased fatigue, reduced functional performance, and poorer quality of life when compared to matched controls. PMID:24011222

  2. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  3. Effectiveness of locomotion training in a home visit preventive care project: one-group pre-intervention versus post-intervention design study.

    PubMed

    Ito, Shinya; Hashimoto, Mari; Aduma, Saori; Yasumura, Seiji

    2015-11-01

    Locomotion training in a home visit-type preventive-care program has been reported elsewhere. However, continuation of appropriate exercises in a home setting is difficult, and few reports are available on locomotion training in a home setting. The objective of this study was to evaluate the effectiveness of locomotion training over 3 months in a home visit-type preventive-care program for improvement of motor function among elderly people. Nine hundred and fifty-eight elderly people in Tendo City in Japan who were not currently attending any preventive-care program were invited to participate in the study, and 87 were enrolled. In the pre-intervention and post-intervention assessments, we administered an interview survey (the Kihon Checklist), the timed one-leg standing test with eyes open and the sit-to-stand test, at the participants' homes. The intervention involved one set of training exercises with the participants standing on each leg for 1 min and squatting five or six times. The participants were asked to repeat one set of the exercises three times a day at home. In addition, the participants were regularly asked over the telephone about their performance of the exercises. Physical strength, cognitive function, and total scores of the Kihon Checklist were significantly lower after the intervention than before. In addition, the one-leg standing test time was significantly longer after the intervention (mean ± SD, 23.9 ± 35.4) than before (15.7 ± 20.5), and the sit-to-stand test time was significantly shorter after the intervention (13.0 ± 6.2) than before (14.8 ± 8.3). Locomotion training in a home-visit preventive-care program with telephone support effectively improved the motor function of elderly people who were not currently attending any preventive-care program organized by the long-term care insurance system.

  4. Performance-based measures associate with frailty in patients with end-stage liver disease

    PubMed Central

    Lai, Jennifer C.; Volk, Michael L; Strasburg, Debra; Alexander, Neil

    2016-01-01

    Background Physical frailty, as measured by the Fried Frailty Index, is increasingly recognized as a critical determinant of outcomes in cirrhotics. However, its utility is limited by the inclusion of self-reported components. We aimed to identify performance-based measures associated with frailty in patients with cirrhosis. Methods Cirrhotics ≥50 years underwent: 6-minute walk test (6MWT, cardiopulmonary endurance), chair stands in 30 seconds (muscle endurance), isometric knee extension (lower extremity strength), unipedal stance time (static balance), and maximal step length (dynamic balance/coordination). Linear regression associated each physical performance test with frailty. Principal components exploratory factor analysis evaluated the inter-relatedness of frailty and the 5 physical performance tests. Results Of forty cirrhotics, with a median age of 64 years and Model for End-stage Liver Disease (MELD) MELD of 12,10 (25%) were frail by Fried Frailty Index ≥3. Frail cirrhotics had poorer performance in 6MWT distance (231 vs. 338 meters), 30 second chair stands (7 vs. 10), isometric knee extension (86 vs. 122 Newton meters), and maximal step length (22 vs. 27 inches) [p≤0.02 for each]. Each physical performance test was significantly associated with frailty (p<0.01), even after adjustment for MELD or hepatic encephalopathy. Principal component factor analysis demonstrated substantial, but unique, clustering of each physical performance test to a single factor – frailty. Conclusion Frailty in cirrhosis is a multi-dimensional construct that is distinct from liver dysfunction and incorporates endurance, strength, and balance. Our data provide specific targets for prehabilitation interventions aimed at reducing frailty in cirrhotics in preparation for liver transplantation. PMID:27495749

  5. Motor and cognitive development: the role of karate.

    PubMed

    Alesi, Marianha; Bianco, Antonino; Padulo, Johnny; Vella, Francesco Paolo; Petrucci, Marco; Paoli, Antonio; Palma, Antonio; Pepi, Annamaria

    2014-04-01

    regular physical activity has an effect on biological responses in both muscles and organs that, in turn, alter the structure and functions of the brain. Therefore, this study aims at comparing motor (sprint, coordination ability and explosive legs strength skills) and cognitive abilities (working memory, attention, executive functioning) in children. 39 children with average chronological age of 9 years were divided in: Karatekas (n=19) and Sedentary (n=20) groups. Their abilities were measured by motor and cognitive tests. Motor skills were assessed through a battery composed by the 20 mt Sprint test, the Agility test and the Standing board jump Test. Cognitive profile was assessed by a battery of tests derived from BVN 5-11, "Batteria di Valutazione Neuropsicologica per l'Et à Evolutiva": Visual discrimination test, Reaction time test, Forwards and Backwards Digit Span Tests, Corsi Block-Tapping test and Tower of London. our results reveal significant differences between two groups (p < 0.05). Karate children show better speed times, explosive legs strength and coordination skills. They scored better on working memory, visual selective attention and executive functions. karate exercise training shows global benefits resulting in physiological and psychological gains in children.

  6. Motor and cognitive development: the role of karate

    PubMed Central

    Alesi, Marianha; Bianco, Antonino; Padulo, Johnny; Vella, Francesco Paolo; Petrucci, Marco; Paoli, Antonio; Palma, Antonio; Pepi, Annamaria

    2014-01-01

    Summary Background: regular physical activity has an effect on biological responses in both muscles and organs that, in turn, alter the structure and functions of the brain. Therefore, this study aims at comparing motor (sprint, coordination ability and explosive legs strength skills) and cognitive abilities (working memory, attention, executive functioning) in children. Methods: 39 children with average chronological age of 9 years were divided in: Karatekas (n=19) and Sedentary (n=20) groups. Their abilities were measured by motor and cognitive tests. Motor skills were assessed through a battery composed by the 20 mt Sprint test, the Agility test and the Standing board jump Test. Cognitive profile was assessed by a battery of tests derived from BVN 5–11, “Batteria di Valutazione Neuropsicologica per l’Et à Evolutiva”: Visual discrimination test, Reaction time test, Forwards and Backwards Digit Span Tests, Corsi Block-Tapping test and Tower of London. Results: our results reveal significant differences between two groups (p < 0.05). Karate children show better speed times, explosive legs strength and coordination skills. They scored better on working memory, visual selective attention and executive functions. Conclusion: karate exercise training shows global benefits resulting in physiological and psychological gains in children. PMID:25332920

  7. Cardiorespiratory Fitness and Muscular Strength as Mediators of the Influence of Fatness on Academic Achievement.

    PubMed

    García-Hermoso, Antonio; Esteban-Cornejo, Irene; Olloquequi, Jordi; Ramírez-Vélez, Robinson

    2017-08-01

    To examine the combined association of fatness and physical fitness components (cardiorespiratory fitness [CRF] and muscular strength) with academic achievement, and to determine whether CRF and muscular strength are mediators of the association between fatness and academic achievement in a nationally representative sample of adolescents from Chile. Data were obtained for a sample of 36 870 adolescents (mean age, 13.8 years; 55.2% boys) from the Chilean System for the Assessment of Educational Quality test for eighth grade in 2011, 2013, and 2014. Physical fitness tests included CRF (20-m shuttle run) and muscular strength (standing long jump). Weight, height, and waist circumference were assessed, and body mass index and waist circumference-to-height ratio were calculated. Academic achievement in language and mathematics was assessed using standardized tests. The PROCESS script developed by Hayes was used for mediation analysis. Compared with unfit and high-fatness adolescents, fit and low-fatness adolescents had significantly higher odds for attaining high academic achievement in language and mathematics. However, in language, unfit and low-fatness adolescents did not have significantly higher odds for obtaining high academic achievement. Those with high fatness had higher academic achievement (both language and mathematics) if they were fit. Linear regression models suggest a partial or full mediation of physical fitness in the association of fatness variables with academic achievement. CRF and muscular strength may attenuate or even counteract the adverse influence of fatness on academic achievement in adolescents. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Reference values for developing responsive functional outcome measures across the lifespan.

    PubMed

    McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Burns, Joshua

    2017-04-18

    To generate a reference dataset of commonly performed functional outcome measures in 1,000 children and adults and investigate the influence of demographic, anthropometric, strength, and flexibility characteristics. Twelve functional outcome measures were collected from 1,000 healthy individuals aged 3-101 years: 6-minute walk test, 30-second chair stand test, timed stairs test, long jump, vertical jump, choice stepping reaction time, balance (Star Excursion Balance Test, tandem stance eyes open and closed, single-leg stance eyes closed), and dexterity (9-hole peg test, Functional Dexterity Test). Correlation and multiple regression analyses were performed to identify factors independently associated with each measure. Age- and sex-stratified reference values for functional outcome measures were generated. Functional performance increased through childhood and adolescence, plateaued during adulthood, and declined in older adulthood. While balance did not differ between the sexes, male participants generally performed better at gross motor tasks while female participants performed better at dexterous tasks. Height was the most consistent correlate of functional performance in children, while lower limb muscle strength was a major determinant in adolescents and adults. In older adults, age, lower limb strength, and joint flexibility explained up to 63% of the variance in functional measures. These normative reference values provide a framework to accurately track functional decline associated with neuromuscular disorders and assist development and validation of responsive outcome measures for therapeutic trials. © 2017 American Academy of Neurology.

  9. Enhancing of women functional status with metabolic syndrome by cardioprotective and anti-inflammatory effects of combined aerobic and resistance training.

    PubMed

    Tibana, Ramires Alsamir; Nascimento, Dahan da Cunha; de Sousa, Nuno Manuel Frade; de Souza, Vinicius Carolino; Durigan, João; Vieira, Amilton; Bottaro, Martim; Nóbrega, Otávio de Toledo; de Almeida, Jeeser Alves; Navalta, James Wilfred; Franco, Octavio Luiz; Prestes, Jonato

    2014-01-01

    These data describe the effects of combined aerobic plus resistance training (CT) with regards to risk factors of metabolic syndrome (MetS), quality of life, functional capacity, and pro- and anti-inflammatory cytokines in women with MetS. In this context, thirteen women (35.4 ± 6.2 yr) completed 10 weeks of CT consisting of three weekly sessions of ~60 min aerobic training (treadmill at 65-70% of reserve heart rate, 30 min) and resistance training (3 sets of 8-12 repetitions maximum for main muscle groups). Dependent variables were maximum chest press strength; isometric hand-grip strength; 30 s chair stand test; six minute walk test; body mass; body mass index; body adiposity index; waist circumference; systolic (SBP), diastolic and mean blood pressure (MBP); blood glucose; HDL-C; triglycerides; interleukins (IL) 6, 10 and 12, osteoprotegerin (OPG) and serum nitric oxide metabolite (NOx); quality of life (SF-36) and Z-Score of MetS. There was an improvement in muscle strength on chest press (p = 0.009), isometric hand-grip strength (p = 0.03) and 30 s chair stand (p = 0.007). There was a decrease in SBP (p = 0.049), MBP (p = 0.041), Z-Score of MetS (p = 0.046), OPG (0.42 ± 0.26 to 0.38 ± 0.19 ng/mL, p<0.05) and NOx (13.3 ± 2.3 µmol/L to 9.1 ± 2.3 µmol/L; p<0.0005). IL-10 displayed an increase (13.6 ± 7.5 to 17.2 ± 12.3 pg/mL, p < 0.05) after 10 weeks of training. Combined training also increased the perception of physical capacity (p = 0.011). This study endorses CT as an efficient tool to improve blood pressure, functional capacity, quality of life and reduce blood markers of inflammation, which has a clinical relevance in the prevention and treatment of MetS.

  10. Fitness testing as a discriminative tool for the diagnosis and monitoring of fibromyalgia.

    PubMed

    Aparicio, V A; Carbonell-Baeza, A; Ruiz, J R; Aranda, P; Tercedor, P; Delgado-Fernández, M; Ortega, F B

    2013-08-01

    We aimed to determine the ability of a set of physical fitness tests to discriminate between presence/absence of fibromyalgia (FM) and moderate/severe FM. The sample comprised 94 female FM patients (52 ± 8 years) and 66 healthy women (54 ± 6 years). We assessed physical fitness by means of the 30-s chair stand, handgrip strength, chair sit and reach, back scratch, blind flamingo, 8-feet up and go, and 6-min walking tests. Patients were classified as having moderate FM if the score in the Fibromyalgia Impact Questionnaire (FIQ) was <70 and as having severe FM if the FIQ was ≥70. FM patients and patients with severe FM performed worse in most of the fitness tests studied (P < 0.001). Except the back scratch test, all the tests were able to discriminate between presence and absence of FM [area under the curve (AUC) = 0.66 to 0.92; P ≤ 0.001], and four tests also discriminated FM severity (AUC = 0.62 to 0.66; P ≤ 0.05). The 30-s chair stand test showed the highest ability to discriminate FM presence and severity (AUC = 0.92, P < 0.001; and AUC = 0.66, P = 0.008, respectively), being the corresponding discriminating cutoffs 9 and 6 repetitions, respectively. Physical fitness in general, and particularly the 30-s chair stand test, is able to discriminate between women with FM from those without FM, as well as between those with moderate FM from their peers with severe FM. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Steel shear strength of anchors with stand-off base plates.

    DOT National Transportation Integrated Search

    2013-09-01

    Sign and signal structures are often connected to concrete foundations through a stand-off annular base plate with a double-nut anchor bolt connection, which leaves exposed anchor bolt lengths below leveling nuts used in these connections. Cantilever...

  12. Health-related physical fitness measures: reference values and reference equations for use in clinical practice.

    PubMed

    Tveter, Anne Therese; Dagfinrud, Hanne; Moseng, Tuva; Holm, Inger

    2014-07-01

    To provide reference values and reference equations for frequently used clinical field tests of health-related physical fitness for use in clinical practice. Cross-sectional design. General community. Convenience sample of volunteers (N=370) between 18 and 90 years of age were recruited from a wide range of settings (ie, work sites, schools, community centers for older adults) and different geographic locations (ie, urban, suburban, rural) in southeastern Norway. Not applicable. The participants conducted 5 clinical field tests (6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, fingertip-to-floor test). The results of the field tests showed that performance remained unchanged until approximately 50 years of age; after that, performance deteriorated with increasing age. Grip strength (79%), meters walked in 6 minutes (60%), and seconds used on the stair test (59%) could be well predicted by age, sex, height, and weight in participants ≥50 years of age, whereas the performance on all tests was less well predicted in participants <50 years of age. The reference values and reference equations provided in this study may increase the applicability and interpretability of the 6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, and fingertip-to-floor test in clinical practice. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Can chronic multimorbidity explain the age-related differences in strength, speed and balance in older adults?

    PubMed

    Welmer, Anna-Karin; Kåreholt, Ingemar; Angleman, Sara; Rydwik, Elisabeth; Fratiglioni, Laura

    2012-10-01

    It is known that physical performance declines with age in general, however there remains much to be understood in terms of age-related differences amongst older adults across a variety of physical components (such as speed, strength and balance), and particularly in terms of the role played by multimorbidity of chronic diseases. We aimed to detect the age-related differences across four components of physical performance and to explore to what extent chronic diseases and multimorbidity may explain such differences. We analyzed cross-sectional data from a population-based sample of 3323 people, aged 60 years and older from the SNAC-K study, Stockholm, Sweden. Physical performance was assessed by trained nurses using several tests (grip strength, walking speed, balance and chair stands). Clinical diagnoses were made by the examining physician based on clinical history and examination. Censored normal regression analyses showed that the 72-90+ year-old persons had 17-40% worse grip strength, 44-86% worse balance, 30-86% worse chair stand score, and 21-59% worse walking speed, compared with the 60-66 year-old persons. Chronic diseases were strongly associated with physical impairment, and this association was particularly strong among the younger men. However, chronic diseases explained only some of the age-related differences in physical performance. When controlling for chronic diseases in the analyses, the age-related differences in physical performance changed 1-11%. In spite of the strong association between multimorbidity and physical impairment, chronic morbidities explained only a small part of the age-related differences in physical performance.

  14. Associations between bone mineral density, grip strength, and lead body burden in older men.

    PubMed

    Khalil, Naila; Faulkner, Kimberly A; Greenspan, Susan L; Cauley, Jane A

    2014-01-01

    To study the association between blood lead concentration (BPb) and bone mineral density (BMD), physical function, and cognitive function in noninstitutionalized community-dwelling older men. Cross-sectional study. University of Pittsburgh clinic, Pittsburgh, Pennsylvania. Non-Hispanic Caucasian men aged 65 and older (N = 445) recruited as a subset of a prospective cohort for the Osteoporotic Fractures in Men Study. BPb was measured in 2007/08. From 2007 to 2009, BMD (g/cm(2)) was measured using dual-energy X-ray absorptiometry. At the same time, physical performance was measured using five tests: grip strength, leg extension power, walking speed, narrow-walk pace, and chair stands. Cognitive performance was assessed using the modified Mini-Mental State Examination and the Trail-Making Test Part B. Participants were categorized into quartiles of BPb. Multivariate regression analysis was used to evaluate the independent relationship between BPb, BMD, and cognitive and physical function. Mean BPb ± standard deviation was 2.25 ± 1.20 μg/dL (median 2 μg/dL, range 1-10 μg/dL). In multivariate-adjusted models, men in higher BPb quartiles had lower BMD at femoral neck and total hip (P-trend < .001 for both). Men with higher BPb had lower age-adjusted score for grip strength (P-trend < .001), although this association was not significant in multivariate-adjusted models (P-trend < .15). BPb was not associated with lumbar spine BMD, cognition, leg extension power, walking speed, narrow-walk pace, or chair stands. Environmental lead exposure may adversely affect bone health in older men. These findings support consideration of environmental exposure in age-associated bone fragility. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  15. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    PubMed

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  16. Average Stand Age from Forest Inventory Plots Does Not Describe Historical Fire Regimes in Ponderosa Pine and Mixed-Conifer Forests of Western North America.

    PubMed

    Stevens, Jens T; Safford, Hugh D; North, Malcolm P; Fried, Jeremy S; Gray, Andrew N; Brown, Peter M; Dolanc, Christopher R; Dobrowski, Solomon Z; Falk, Donald A; Farris, Calvin A; Franklin, Jerry F; Fulé, Peter Z; Hagmann, R Keala; Knapp, Eric E; Miller, Jay D; Smith, Douglas F; Swetnam, Thomas W; Taylor, Alan H

    Quantifying historical fire regimes provides important information for managing contemporary forests. Historical fire frequency and severity can be estimated using several methods; each method has strengths and weaknesses and presents challenges for interpretation and verification. Recent efforts to quantify the timing of historical high-severity fire events in forests of western North America have assumed that the "stand age" variable from the US Forest Service Forest Inventory and Analysis (FIA) program reflects the timing of historical high-severity (i.e. stand-replacing) fire in ponderosa pine and mixed-conifer forests. To test this assumption, we re-analyze the dataset used in a previous analysis, and compare information from fire history records with information from co-located FIA plots. We demonstrate that 1) the FIA stand age variable does not reflect the large range of individual tree ages in the FIA plots: older trees comprised more than 10% of pre-stand age basal area in 58% of plots analyzed and more than 30% of pre-stand age basal area in 32% of plots, and 2) recruitment events are not necessarily related to high-severity fire occurrence. Because the FIA stand age variable is estimated from a sample of tree ages within the tree size class containing a plurality of canopy trees in the plot, it does not necessarily include the oldest trees, especially in uneven-aged stands. Thus, the FIA stand age variable does not indicate whether the trees in the predominant size class established in response to severe fire, or established during the absence of fire. FIA stand age was not designed to measure the time since a stand-replacing disturbance. Quantification of historical "mixed-severity" fire regimes must be explicit about the spatial scale of high-severity fire effects, which is not possible using FIA stand age data.

  17. Average Stand Age from Forest Inventory Plots Does Not Describe Historical Fire Regimes in Ponderosa Pine and Mixed-Conifer Forests of Western North America

    PubMed Central

    Stevens, Jens T.; Safford, Hugh D.; North, Malcolm P.; Fried, Jeremy S.; Gray, Andrew N.; Brown, Peter M.; Dolanc, Christopher R.; Dobrowski, Solomon Z.; Falk, Donald A.; Farris, Calvin A.; Franklin, Jerry F.; Fulé, Peter Z.; Hagmann, R. Keala; Knapp, Eric E.; Miller, Jay D.; Smith, Douglas F.; Swetnam, Thomas W.; Taylor, Alan H.

    2016-01-01

    Quantifying historical fire regimes provides important information for managing contemporary forests. Historical fire frequency and severity can be estimated using several methods; each method has strengths and weaknesses and presents challenges for interpretation and verification. Recent efforts to quantify the timing of historical high-severity fire events in forests of western North America have assumed that the “stand age” variable from the US Forest Service Forest Inventory and Analysis (FIA) program reflects the timing of historical high-severity (i.e. stand-replacing) fire in ponderosa pine and mixed-conifer forests. To test this assumption, we re-analyze the dataset used in a previous analysis, and compare information from fire history records with information from co-located FIA plots. We demonstrate that 1) the FIA stand age variable does not reflect the large range of individual tree ages in the FIA plots: older trees comprised more than 10% of pre-stand age basal area in 58% of plots analyzed and more than 30% of pre-stand age basal area in 32% of plots, and 2) recruitment events are not necessarily related to high-severity fire occurrence. Because the FIA stand age variable is estimated from a sample of tree ages within the tree size class containing a plurality of canopy trees in the plot, it does not necessarily include the oldest trees, especially in uneven-aged stands. Thus, the FIA stand age variable does not indicate whether the trees in the predominant size class established in response to severe fire, or established during the absence of fire. FIA stand age was not designed to measure the time since a stand-replacing disturbance. Quantification of historical “mixed-severity” fire regimes must be explicit about the spatial scale of high-severity fire effects, which is not possible using FIA stand age data. PMID:27196621

  18. Resistance training-induced gains in muscle strength, body composition, and functional capacity are attenuated in elderly women with sarcopenic obesity

    PubMed Central

    de Oliveira Silva, Alessandro; Dutra, Maurílio Tiradentes; de Moraes, Wilson Max Almeida Monteiro; Funghetto, Silvana Schwerz; Lopes de Farias, Darlan; dos Santos, Paulo Henrique Fernandes; Vieira, Denis Cesar Leite; Nascimento, Dahan da Cunha; Orsano, Vânia Silva Macedo; Schoenfeld, Brad J; Prestes, Jonato

    2018-01-01

    Objectives The purpose of this study was to compare the effects of resistance training (RT) on body composition, muscle strength, and functional capacity in elderly women with and without sarcopenic obesity (SO). Methods A total of 49 women (aged ≥60 years) were divided in two groups: without SO (non-SO, n=41) and with SO (n=8). Both groups performed a periodized RT program consisting of two weekly sessions for 16 weeks. All measures were assessed at baseline and postintervention, including anthropometry and body composition (dual-energy X-ray absorptiometry), muscle strength (one repetition maximum) for chest press and 45° leg press, and functional capacity (stand up, elbow flexion, timed “up and go”). Results After the intervention, only the non-SO group presented significant reductions in percentage body fat (−2.2%; P=0.006), waist circumference (−2.7%; P=0.01), waist-to-hip ratio (−2.3; P=0.02), and neck circumference (−1.8%; P=0.03) as compared with baseline. Muscle strength in the chest press and biceps curl increased in non-SO only (12.9% and 11.3%, respectively), while 45° leg press strength increased in non-SO (50.3%) and SO (40.5%) as compared with baseline. Performance in the chair stand up and timed “up and go” improved in non-SO only (21.4% and −8.4%, respectively), whereas elbow flexion performance increased in non-SO (23.8%) and SO (21.4%). Effect sizes for motor tests were of higher magnitude in the non-SO group, and in general, considered “moderate” compared to “trivial” in the SO group. Conclusion Results suggest that adaptations induced by 16 weeks of RT are attenuated in elderly woman with SO, compromising improvements in adiposity indices and gains in muscle strength and functional capacity. PMID:29588579

  19. State Defense Force Monograph Series: Mission Growth of the SDF from the Cold War

    DTIC Science & Technology

    2009-01-01

    stand for, is of no value. The health and well being of our citizens are in danger of biological , chemical and even “dirty” nuclear weapons as well...determine the strengths and weakness under each situation. ! Chemical Model – A model used to test the impact of a Chemical, Biological or... Bioethics , 7(9): 31-32. Department of Defense Task Force on Mental Health. “An achievable vision: Report of the Department of Defense Task Force on

  20. The Effect Of Age At Harvest On Bending And Tensile Properties Of Loblolly Pine From The Coastal Plain

    Treesearch

    Robert H. McAlister; Alexander Clark; Joseph R. Saucier

    1997-01-01

    The effect of rotation age on strength and stiffness of lumber produced from unthinned loblolly pine stands in the Coastal Plain of Georgia was examined. Six stands representing 22-, 28-, and 40-year-old roations were sampled. A stratified random sample of trees 8 to 16 inches in diameter at breast height was selected from each stand and processed into lumber....

  1. Determinants of each domain of the Short Physical Performance Battery in COPD.

    PubMed

    Bernabeu-Mora, Roberto; Giménez-Giménez, Luz M; Montilla-Herrador, Joaquina; García-Guillamón, Gloria; García-Vidal, José Antonio; Medina-Mirapeix, Francesc

    2017-01-01

    The Short Physical Performance Battery (SPPB) is an assessment tool with good prognostic value in COPD. It includes the following: standing balance, 4 m gait speed test (4MGS), and the timed five-repetition sit-to-stand test (5STS). The specific differences in determinants between these three tasks have not been adequately characterized in COPD patients. We aimed to identify health-related, functional, and psychological determinants of each SPPB test. We conducted a cross-sectional analysis of 137 patients with stable COPD. Patients performed the SPPB, quadriceps muscle strength (QMS), exercise tolerance test (6-min walk test [6MWT]), and pulmonary function; and health-related and psychological factors, physical activity, the COPD assessment test (CAT), body mass index, age, and depression were assessed. Separate multivariable regression models predicting the 4MGS, 5STS, and balance test results described 31%, 39.1%, and 12.1% of the variance for each test, respectively. QMS was negatively associated with all three tests. The 6MWT was negatively associated with the 4MGS and 5STS. Depression and age were positively associated with 4MGS scores, whereas CAT and age were positively associated with 5STS scores. The three SPPB tests did not provide equivalent information regarding a COPD patient's status. The 5STS was associated with health status factors, while the 4MGS was associated with psychological factors.

  2. Determinants of each domain of the Short Physical Performance Battery in COPD

    PubMed Central

    Bernabeu-Mora, Roberto; Giménez-Giménez, Luz M; Montilla-Herrador, Joaquina; García-Guillamón, Gloria; García-Vidal, José Antonio; Medina-Mirapeix, Francesc

    2017-01-01

    Background The Short Physical Performance Battery (SPPB) is an assessment tool with good prognostic value in COPD. It includes the following: standing balance, 4 m gait speed test (4MGS), and the timed five-repetition sit-to-stand test (5STS). The specific differences in determinants between these three tasks have not been adequately characterized in COPD patients. We aimed to identify health-related, functional, and psychological determinants of each SPPB test. Methods We conducted a cross-sectional analysis of 137 patients with stable COPD. Patients performed the SPPB, quadriceps muscle strength (QMS), exercise tolerance test (6-min walk test [6MWT]), and pulmonary function; and health-related and psychological factors, physical activity, the COPD assessment test (CAT), body mass index, age, and depression were assessed. Results Separate multivariable regression models predicting the 4MGS, 5STS, and balance test results described 31%, 39.1%, and 12.1% of the variance for each test, respectively. QMS was negatively associated with all three tests. The 6MWT was negatively associated with the 4MGS and 5STS. Depression and age were positively associated with 4MGS scores, whereas CAT and age were positively associated with 5STS scores. Conclusion The three SPPB tests did not provide equivalent information regarding a COPD patient’s status. The 5STS was associated with health status factors, while the 4MGS was associated with psychological factors. PMID:28883721

  3. Strength and conditioning practices in rowing.

    PubMed

    Gee, Thomas I; Olsen, Peter D; Berger, Nicolas J; Golby, Jim; Thompson, Kevin G

    2011-03-01

    There is limited published research on the practices of strength and conditioning (S &C) coaches in Great Britain. Information about training program design would be useful in developing models of good practice and ecologically valid intervention studies. The aim of this research was to quantify the training practices of coaches responsible for the S&C of rowing athletes. A questionnaire was developed that consisted of 6 sections: (a) personal details, (b) physical testing, (c) strength and power development, (d) flexibility development, (e) unique aspects of the program, and (f) any further relevant comments regarding the athletes prescribed training program. Twenty-two rowing and 10 S&C coaches with an average of 10.5 ± 7.2 years' experience agreed to complete the questionnaire. Approximately, 34% coached rowers of Olympic standard, 34% coached national standard, 3% coached regional standard, 19% coached club standard, and 10% coached university standard rowers. All coaches agreed that strength training enhanced rowing performance and the majority (74%) indicated that athletes' strength trained 2-3 times a week. Almost all coaches (94%) reported their rowers performed strength training, with 81% using Olympic lifting, and 91% employing a periodized training model. The clean (63%) and squat (27%) were rated the most important prescribed exercises. Approximately 50% of coaches used plyometrics such as depth jumps, box drills, and standing jumps. Ninety-four percent indicated they conducted physical testing on their rowers, typically assessing cardiovascular endurance (80%), muscular power (70%), muscular strength (70%), and anaerobic capacity (57%). This research represents the only published survey to date on the S&C practices in rowing within Great Britain.

  4. Accuracy of Body Mass Index Versus Lean Mass Index for Prediction of Sarcopenia in Older Women.

    PubMed

    Benton, M J; Silva-Smith, A L

    2018-01-01

    We compared accuracy of body mass index (BMI) versus lean mass index (LMI) to predict sarcopenia in 58 community-dwelling women (74.1±0.9 years). Lean mass was measured with multi-frequency bioelectrical impedance analysis, and strength was measured with Arm Curl test, Chair Stand test, and handgrip dynamometry. Sarcopenia was defined as low LMI. When categorized by BMI, normal women had less absolute lean mass (37.6±1.0 vs. 42.6±0.9 kg; P<0.001) and less relative lean mass (14.1±0.2 vs. 16.1±0.2 kg/m2; P<0.001) compared to overweight/obese women, but no differences in strength. When categorized by LMI, normal women had more absolute lean mass (44.0±0.7 vs. 35.7±0.7 kg; P<0.001), more relative lean mass (16.2±0.2 vs. 13.8±0.2 kg/m2; P<0.001), and greater upper body strength (16.7±0.9 vs. 14.2±0.6 arm curls; P<0.05) compared to women with low LMI. BMI failed to accurately predict low values of lean mass and strength. For clinical assessment, calculation of LMI rather than BMI is appropriate.

  5. Promoting balance and strength in the middle-aged workforce.

    PubMed

    Granacher, U; Wick, C; Rueck, N; Esposito, C; Roth, R; Zahner, L

    2011-01-01

    The prevalence of sustaining fall-related injuries is high in the middle-aged workforce. Deficits in postural control/muscle strength represent important fall-risk factors. The objective of this study was to examine the impact of balance and strength training followed by detraining on postural control and muscle strength in the workforce. Thirty-two adults with sedentary office work participated in this study and were assigned to an intervention (age 56.0 ± 3.7 yrs) or a control group (age 55.5 ± 3.4 yrs). The intervention group participated in 8 weeks of balance and strength training conducted at the worksite, followed by 8 weeks of detraining. Tests included the measurement of (a) total centre of pressure (COP) displacements during one-legged standing, (b) gait velocity and stride-to-stride variability, (c) peak isometric/isokinetic torque and rate of torque development (RTD) of the plantar flexors, and (d) jumping height. After training, significant improvements in COP displacements, gait velocity, peak isometric/isokinetic torque, RTD, and jumping height were observed. During detraining, muscle strength deteriorated, whereas postural control improved. This fall-preventive training program conducted at the worksite proved to be feasible and effective. It is suggested that this training program should be permanently conducted to maintain/improve muscle strength. © Georg Thieme Verlag KG Stuttgart · New York.

  6. [Strength, flexibility, balance, resistance and flexibility assessment according to body mass index in active older women].

    PubMed

    Vaquero-Cristóbal, Raquel; Martínez González-Moro, Ignacio; Alacid Cárceles, Fernando; Ros Simón, Esperanza

    2013-01-01

    Overweight and obesity are increasing at an alarming rate among older people. This is mainly because this population is predominantly sedentary. The aim of this study was to classify, according to the body mass index (BMI), a group of older active women and to evaluate the different basic physical abilities as a function of this. The BMI and fitness were evaluated in 60 elderly active women (mean age: 66.14 ± 6.59 years) using the 2-minute step test, arm curl test, chair stand test, back scratch test, chair-sit and reach-test, flamenco test, and 8-foot up-and-go test. It was found that 52.23% of the women studied had a normal BMI and 47.76% were slightly overweight. There were no cases of obesity or underweight. Women with normal BMI had better values in all tests than overweight women. Significant differences were found in the flamenco test (P<.05), and 8-foot up-and-go test (P<.01). Older women who usually do physical activity had a normal or slightly overweight BMI. It was also found that women with lower BMI have better resistance, flexibility, balance and strength. Copyright © 2012 SEGG. Published by Elsevier Espana. All rights reserved.

  7. Repetitive Daily Point of Choice Prompts and Occupational Sit-Stand Transfers, Concentration and Neuromuscular Performance in Office Workers: An RCT

    PubMed Central

    Donath, Lars; Faude, Oliver; Schefer, Yannick; Roth, Ralf; Zahner, Lukas

    2015-01-01

    Objective: Prolonged office sitting time adversely affects neuromuscular and cardiovascular health parameters. As a consequence, the present study investigated the effects of prompting the use of height-adjustable working desk (HAWD) on occupational sitting and standing time, neuromuscular outcomes and concentration in office workers. Methods: A single-blinded randomized controlled trial (RCT) with parallel group design was conducted. Thirty-eight office workers were supplied with HAWDs and randomly assigned (Strata: physical activity (PA), BMI, gender, workload) to a prompt (INT) or non-prompt (CON) group. INT received three daily screen-based prompts within 12 weeks. CON was only instructed once concerning the benefits of using HAWDs prior to the start of the study. Sitting and standing times were objectively assessed as primary outcomes for one entire working week using the ActiGraph wGT3X-BT at baseline (pre), after 6 (mid) and 12 weeks (post). Concentration (d2-test), postural sway during upright stance (under single, dual and triple task) and lower limb strength endurance (heel-rise) were collected as secondary outcomes. Results: With large but not statistically significant within group effects from pre to post, INT increased weekly standing time at work by 9% (p = 0.22, d = 0.8) representing an increase from 7.2 h (4.8) to 9.7 (6.6) h (p = 0.07). Concentration and neuromuscular performance did not change from pre to post testing (0.23 < p < 0.95; 0.001 < ηp² < 0.05). Conclusion: Low-frequent and low cost screen-based point of choice prompts (3 per day within 12 weeks) already result in notable increases of occupational standing time of approx. daily 30 min. These stimuli, however, did not relevantly affect neuromuscular outcomes.   PMID:25903058

  8. Canopy tree species determine herb layer biomass and species composition on a reclaimed mine spoil heap.

    PubMed

    Rawlik, Mateusz; Kasprowicz, Marek; Jagodziński, Andrzej M; Kaźmierowski, Cezary; Łukowiak, Remigiusz; Grzebisz, Witold

    2018-09-01

    According facilitative models of succession, trees are great forest ecosystem engineers. The strength of tree stand influences on habitat were tested in rather homogenous conditions where heterogeneity of site condition was not an important influence. We hypothesized that canopy composition affects total aboveground vascular herb layer biomass (THB) and species composition of herb layer plant biomass (SCHB) more significantly than primary soil fertility or slope exposure. The study was conducted in 227 randomly selected research plots in seven types of forest stands: pure with Alnus glutinosa, Betula pendula, Pinus sylvestris, Quercus petraea and Robinia pseudoacacia, and mixed with dominance of Acer pseudoplatanus or Betula pendula located on hilltop and northern, eastern, western, and southern slopes on a reclaimed, afforested post-mining spoil heap of the Bełchatów Brown Coal Mine (Poland). Generalized linear models (GLZ) showed that tree stand species were the best predictors of THB. Non-parametric variance tests showed significantly higher (nearly four times) THB under canopies of A. glutinosa, R. pseudoacacia, B. pendula and Q. petraea, compared to the lowest THB found under canopies of P. sylvestris and mixed with A. pseudoplatanus. Redundancy Analysis (RDA) showed that SCHB was significantly differentiated along gradients of light-nutrient herb layer species requirements. RDA and non-parametric variance tests showed that SCHB under canopies of A. glutinosa, R. pseudoacacia and mixed with A. pseudoplatanus had large shares of nitrophilous ruderal species (32%, 31% and 11%, respectively), whereas SCHB under B. pendula, Q. petraea, mixed with B. pendula and P. sylvestris were dominated by light-demanding meadow (49%, 51%, 51% and 36%, respectively) and Poaceae species. The results indicated the dominant role of tree stand composition in habitat-forming processes, and although primary site properties had minor importance, they were also modified by tree stand species. Copyright © 2018. Published by Elsevier B.V.

  9. Looking northeast from Test Stand 'A' superstructure towards Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking northeast from Test Stand 'A' superstructure towards Test Stand 'D' tower (4223/E-24, left background), Test Stand 'C' tower (4217/E-18, center), and Test Stand 'B' (4215/E-16, right foreground). - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA

  10. In-Line Heat Treatment and Hot Rolling

    NASA Astrophysics Data System (ADS)

    Raudensky, M.; Horsky, J.; Hnizdil, M. P.; Pohanka, Kotrbacek M.

    2011-01-01

    In-line heat treatment of rolled materials is becoming increasingly used at hot rolling plants. The advantage of this method is the achievement of required material structure without the necessity of reheating. This paper describes a design procedure for cooling sections for the purpose of obtaining the required structure and mechanical properties. The procedure is typically used for the cooling of tubes, rails, long products and plates. Microstructure and nature of grains, grain size and composition determine the overall mechanical behaviour of steel. Heat treatment provides an efficient way to manipulate the properties of steel by controlling the cooling rate. The rate of cooling is defined by a heat transfer coefficient (HTC). Good controllability of HTC can be reached using either air-water or water nozzles. Thus, an on-line heat treatment with the assistance of spray nozzles enables a manufacturing process that can improve product performance by increasing steel strength, hardness and other desirable characteristics. These techniques also allow selective hardening, such that selective areas of a single object can be subjected to different treatments. An experimental stand designed for the study of cooling steel samples has been built at the Brno University of Technology. The stand comprises a movable trolley containing a test sample which moves under the spray at a given velocity. Sensors indicate the temperature history of the tested material. This experimental stand enables simulation of a variety of cooling regimes and evaluates the final structure of tested samples. The same experimental stand is also a tool for use in the design of cooling sections in order to find the required heat treatment procedure and final structure. Examples of the cooling of rails and tubes are given in the paper.

  11. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  12. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  13. FAST TRACK COMMUNICATION: An electromagnetically induced grating by microwave modulation

    NASA Astrophysics Data System (ADS)

    Xiao, Zhi-Hong; Shin, Sung Guk; Kim, Kisik

    2010-08-01

    We study the phenomenon of an electromagnetically induced phase grating in a double-dark state system of 87Rb atoms, the two closely placed lower fold levels of which are coupled by a weak microwave field. Owing to the existence of the weak microwave field, the efficiency of the phase grating is strikingly improved, and an efficiency of approximately 33% can be achieved. Under the action of the weak standing wave field, the high efficiency of the phase grating can be maintained by modulating the strength and detuning of the weak microwave field, increasing the strength of the standing wave field.

  14. Usefulness of a 50-meter round walking test for fall prediction in the elderly requiring long-term care

    PubMed Central

    Hachiya, Mizuki; Murata, Shin; Otao, Hiroshi; Ihara, Takehiko; Mizota, Katsuhiko; Asami, Toyoko

    2015-01-01

    [Purpose] This study aimed to verify the usefulness of a 50-m round walking test developed as an assessment method for walking ability in the elderly. [Subjects] The subjects were 166 elderly requiring long-term care individuals (mean age, 80.5 years). [Methods] In order to evaluate the factors that had affected falls in the subjects in the previous year, we performed the 50-m round walking test, functional reach test, one-leg standing test, and 5-m walking test and measured grip strength and quadriceps strength. [Results] The 50-m round walking test was selected as a variable indicating fall risk based on the results of multiple logistic regression analysis. The cutoff value of the 50-m round walking test for determining fall risk was 0.66 m/sec. The area under the receiver operating characteristic curve was 0.64. The sensitivity of the cutoff value was 65.7%, the specificity was 63.6%, the positive predictive value was 55.0%, the negative predictive value was 73.3%, and the accuracy was 64.5%. [Conclusion] These results suggest that the 50-m round walking test is a potentially useful parameter for the determination of fall risk in the elderly requiring long-term care. PMID:26834327

  15. Usefulness of a 50-meter round walking test for fall prediction in the elderly requiring long-term care.

    PubMed

    Hachiya, Mizuki; Murata, Shin; Otao, Hiroshi; Ihara, Takehiko; Mizota, Katsuhiko; Asami, Toyoko

    2015-12-01

    [Purpose] This study aimed to verify the usefulness of a 50-m round walking test developed as an assessment method for walking ability in the elderly. [Subjects] The subjects were 166 elderly requiring long-term care individuals (mean age, 80.5 years). [Methods] In order to evaluate the factors that had affected falls in the subjects in the previous year, we performed the 50-m round walking test, functional reach test, one-leg standing test, and 5-m walking test and measured grip strength and quadriceps strength. [Results] The 50-m round walking test was selected as a variable indicating fall risk based on the results of multiple logistic regression analysis. The cutoff value of the 50-m round walking test for determining fall risk was 0.66 m/sec. The area under the receiver operating characteristic curve was 0.64. The sensitivity of the cutoff value was 65.7%, the specificity was 63.6%, the positive predictive value was 55.0%, the negative predictive value was 73.3%, and the accuracy was 64.5%. [Conclusion] These results suggest that the 50-m round walking test is a potentially useful parameter for the determination of fall risk in the elderly requiring long-term care.

  16. Neurophysiological Aspects and their relationship to clinical and functional impairment in patients with Chronic Obstructive Pulmonary Disease

    PubMed Central

    de Miranda Rocco, Carolina Chiusoli; Sampaio, Luciana Maria Malosá; Stirbulov, Roberto; Corrêa, João Carlos Ferrari

    2011-01-01

    OBJECTIVE: The purpose was to assess functional (balance L–L and A–P displacement, sit‐to‐stand test (SST) and Tinetti scale – balance and gait) and neurophysiological aspects (patellar and Achilles reflex and strength) relating these responses to the BODE Index. INTRODUCTION: The neurophysiological alterations found in patients with chronic obstructive pulmonary disease (COPD) are associated with the severity of the disease. There is also involvement of peripheral muscle which, in combination with neurophysiological impairment, may further compromise the functional activity of these patients. METHODS: A cross‐sectional study design was used. Twenty‐two patients with moderate to very severe COPD (>60 years) and 16 age‐matched healthy volunteers served as the control group (CG). The subjects performed spirometry and several measures of static and dynamic balance, monosynaptic reflexes, peripheral muscle strength, SST and the 6‐minute walk test. RESULTS: The individuals with COPD had a reduced reflex response, 36.77±3.23 (p<0.05) and 43.54±6.60 (p<0.05), achieved a lower number repetitions on the SST 19.27±3.88 (p<0.05), exhibited lesser peripheral muscle strength on the femoral quadriceps muscle, 24.98±6.88 (p<0.05) and exhibited deficits in functional balance and gait on the Tinetti scale, 26.86±1.69 (p<0.05), compared with the CG. The BODE Index demonstrated correlations with balance assessment (determined by the Tinetti scale), r = 0.59 (p<0.05) and the sit‐to‐stand test, r = 0.78 (p<0.05). CONCLUSIONS: The individuals with COPD had functional and neurophysiological alterations in comparison with the control group. The BODE Index was correlated with the Tinetti scale and the SST. Both are functional tests, easy to administer, low cost and feasible, especially the SST. These results suggest a worse prognosis; however, more studies are needed to identify the causes of these changes and the repercussions that could result in their activities of daily living. PMID:21437448

  17. Balance Performance During Perturbed Standing Is Not Associated With Muscle Strength and Power in Young Adults.

    PubMed

    Zemková, Erika; Jeleň, Michal; Kováčiková, Zuzana; Miklovič, Peter; Svoboda, Zdeněk; Janura, Miroslav

    2017-01-01

    The authors investigate the ways in which varied postural responses to translating platform perturbations are associated with the variables of strength and power. Twenty-four physically active and 27 sedentary young adults were exposed to a set of postural perturbations at varied velocities (10 and 20 cm/s) and the respective accelerations (6.4 and 6.9 m/s 2 ), constant distance (6 cm), and 4 directions of platform motion (forward, backward, left-lateral, and right-lateral). They also performed maximum voluntary isometric contraction (MVC) and chair rising/chair jumping tests. The analysis of variance revealed significant interaction effect for peak center of pressure displacement, direction by velocity: F 3,129 = 24.43, p = .002; and direction by acceleration: F 3,129 = 34.18, p = .001. There were no significant correlations between peak center of pressure displacements and peak force and peak rate of force development measured during MVC in either standing (r = .27-57) or sitting positions (r = .12-51) and peak power during chair jumping (r = .47-.59) in all participants. As such, only a small proportion of variance was explained (9-39%, 3-23%, and 23-41%, respectively). In conclusion, interaction effects indicate that the composition of stimuli strongly influences compensatory responses and this effect is more pronounced in sedentary than in physically active young adults. Nevertheless, the dynamic balance is not associated with muscle strength and power in either group.

  18. Effect of cold indoor environment on physical performance of older women living in the community.

    PubMed

    Lindemann, Ulrich; Oksa, Juha; Skelton, Dawn A; Beyer, Nina; Klenk, Jochen; Zscheile, Julia; Becker, Clemens

    2014-07-01

    the effects of cold on older persons' body and mind are not well documented, but with an increased number of older people with decreasing physical performance, these possible effects need to be understood. to investigate the effect of cold indoor environment on physical performance of older women. cross-sectional experimental study with two test conditions. movement laboratory in a climate chamber. eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). participants were exposed to moderately cold (15°C) and warm/normal (25°C) temperature in a climate chamber in random order with an interval of 1 week. The assessment protocol included leg extensor power (Nottingham Power Rig), sit-to-stand performance velocity (linear encoder), gait speed, walk-ratio (i.e. step length/cadence on an instrumented walk way), maximal quadriceps and hand grip strength. physical performance was lower in 15°C room temperature compared with 25°C room temperature for leg extensor power (P < 0.0001), sit-to-stand performance velocity (P < 0.0001), gait speed (P < 0.0001), walk-ratio (P = 0.016) and maximal quadriceps strength (P = 0.015), but not for hand grip strength. in healthy older women a moderately cold indoor environment decreased important physical performance measures necessary for independent living. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Corrosion Behavior of Steel Reinforcement in Concrete with Recycled Aggregates, Fly Ash and Spent Cracking Catalyst.

    PubMed

    Gurdián, Hebé; García-Alcocel, Eva; Baeza-Brotons, Francisco; Garcés, Pedro; Zornoza, Emilio

    2014-04-21

    The main strategy to reduce the environmental impact of the concrete industry is to reuse the waste materials. This research has considered the combination of cement replacement by industrial by-products, and natural coarse aggregate substitution by recycled aggregate. The aim is to evaluate the behavior of concretes with a reduced impact on the environment by replacing a 50% of cement by industrial by-products (15% of spent fluid catalytic cracking catalyst and 35% of fly ash) and a 100% of natural coarse aggregate by recycled aggregate. The concretes prepared according to these considerations have been tested in terms of mechanical strengths and the protection offered against steel reinforcement corrosion under carbonation attack and chloride-contaminated environments. The proposed concrete combinations reduced the mechanical performance of concretes in terms of elastic modulus, compressive strength, and flexural strength. In addition, an increase in open porosity due to the presence of recycled aggregate was observed, which is coherent with the changes observed in mechanical tests. Regarding corrosion tests, no significant differences were observed in the case of the resistance of these types of concretes under a natural chloride attack. In the case of carbonation attack, although all concretes did not stand the highly aggressive conditions, those concretes with cement replacement behaved worse than Portland cement concretes.

  20. [ALPHA-fitness test battery: health-related field-based fitness tests assessment in children and adolescents].

    PubMed

    Ruiz, J R; España Romero, V; Castro Piñero, J; Artero, E G; Ortega, F B; Cuenca García, M; Jiménez Pavón, D; Chillón, P; Girela Rejón, Ma J; Mora, J; Gutiérrez, A; Suni, J; Sjöstrom, M; Castillo, M J

    2011-01-01

    Hereby we summarize the work developed by the ALPHA (Assessing Levels of Physical Activity) Study and describe the tests included in the ALPHA health-related fitness test battery for children and adolescents. The evidence-based ALPHA-Fitness test battery include the following tests: 1) the 20 m shuttle run test to assess cardiorespiratory fitness; 2) the handgrip strength and 3) standing broad jump to assess musculoskeletal fitness, and 4) body mass index, 5) waist circumference; and 6) skinfold thickness (triceps and subscapular) to assess body composition. Furthermore, we include two versions: 1) the high priority ALPHA health-related fitness test battery, which comprises all the evidence-based fitness tests except the measurement of the skinfold thickness; and 2) the extended ALPHA health-related fitness tests battery for children and adolescents, which includes all the evidence-based fitness tests plus the 4 x 10 m shuttle run test to assess motor fitness.

  1. Validation and reliability of the Physical Activity Scale for the Elderly in Chinese population.

    PubMed

    Ngai, Shirley P C; Cheung, Roy T H; Lam, Priscillia L; Chiu, Joseph K W; Fung, Eric Y H

    2012-05-01

    Physical Activity Scale for the Elderly (PASE) is a widely used questionnaire in epidemiological studies for assessing the physical activity level of elderly. This study aims to translate and validate PASE in Chinese population. Cross-sectional study. Chinese elderly aged 65 or above. The original English version of PASE was translated into Chinese (PASE-C) following standardized translation procedures. Ninety Chinese elderly aged 65 or above were recruited in the community. Test-retest reliability was determined by comparing the scores obtained from two separate administrations by the intraclass correlation coefficient. Validity was evaluated by Spearman's rank correlation coefficients between PASE and Medical Outcome Survey 36-Item Short Form Health Survey (SF-36), grip strength, single-leg-stance, 5 times sit-to-stand and 10-m walk. PASE-C demonstrated good test-retest reliability (intraclass correlation coefficient  = 0.81). Fair to moderate association were found between PASE-C and most of the subscales of SF-36 (rs = 0.285 to 0.578, p < 0.01), grip strength (rs = 0.405 to 0.426, p < 0.001), single-leg-stance (rs = 0.470 to 0.548, p < 0.001), 5 times sit-to-stand (rs = -0.33, p = 0.001) and 10-m walk (rs = -0.281, p = 0.007). PASE-C is a reliable and valid instrument for assessing the physical activity level of elderly in Chinese population.

  2. Physical factors underlying the association between lower walking performance and falls in older people: a structural equation model.

    PubMed

    Shimada, Hiroyuki; Tiedemann, Anne; Lord, Stephen R; Suzukawa, Megumi; Makizako, Hyuma; Kobayashi, Kumiko; Suzuki, Takao

    2011-01-01

    The purpose of this study was to determine the interrelationships between lower limb muscle performance, balance, gait and falls in older people using structural equation modeling. Study participants were two hundred and thirteen people aged 65 years and older (mean age, 80.0 ± 7.1 years), who used day-care services in Japan. The outcome measures were the history of falls three months retrospectively and physical risk factors for falling, including performance in the chair stand test (CST), one-leg standing test (OLS), tandem walk test, 6m walking time, and the timed up-and-go (TUG) test. Thirty-nine (18.3%) of the 213 participants had fallen at least one or more times during the preceding 3 months. The fall group had significantly slower 6m walking speed and took significantly longer to undertake the TUG test than the non-fall group. In a structural equation model, performance in the CST contributed significantly to gait function, and low gait function was significantly and directly associated with falls in older people. This suggests that task-specific strength exercise as well as general mobility retraining should be important components of exercise programs designed to reduce falls in older people. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Feasibility and outcomes of a classical Pilates program on lower extremity strength, posture, balance, gait, and quality of life in someone with impairments due to a stroke.

    PubMed

    Shea, Sarah; Moriello, Gabriele

    2014-07-01

    Pilates is a method that can potentially be used for stroke rehabilitation to address impairments in gait, balance, strength, and posture. The purpose of this case report was to document the feasibility of using Pilates and to describe outcomes of a 9-month program on lower extremity strength, balance, posture, gait, and quality of life in an individual with stroke. The participant was taught Pilates exercises up to two times per week for nine months in addition to traditional rehabilitation in the United States. Outcomes were assessed using the Berg Balance Scale (BBS), Stroke Impact Scale (SIS), GAITRite System(®), 5 repetition sit-to-stand test (STST), and flexicurve. Improvements were found in balance, lower extremity strength, and quality of life. Posture and gait speed remained the same. While these changes cannot be specifically attributed to the intervention, Pilates may have added to his overall rehabilitation program and with some modifications was feasible to use in someone with a stroke. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Effect of Physical Activity versus Health Education on Physical Function, Grip Strength and Mobility.

    PubMed

    Santanasto, Adam J; Glynn, Nancy W; Lovato, Laura C; Blair, Steven N; Fielding, Roger A; Gill, Thomas M; Guralnik, Jack M; Hsu, Fang-Chi; King, Abby C; Strotmeyer, Elsa S; Manini, Todd M; Marsh, Anthony P; McDermott, Mary M; Goodpaster, Bret H; Pahor, Marco; Newman, Anne B

    2017-07-01

    Physical activity (PA) reduces the rate of mobility disability, compared with health education (HE), in at risk older adults. It is important to understand aspects of performance contributing to this benefit. To evaluate intervention effects on tertiary physical performance outcomes. The Lifestyle Interventions and Independence for Elders (LIFE) was a multi-centered, single-blind randomized trial of older adults. Eight field centers throughout the United States. 1635 adults aged 78.9 ± 5.2 years, 67.2% women at risk for mobility disability (Short Physical Performance Battery [SPPB] <10). Moderate PA including walking, resistance and balance training compared with HE consisting of topics relevant to older adults. Grip strength, SPPB score and its components (balance, 4 m gait speed, and chair-stands), as well as 400 m walking speed. Total SPPB score was higher in PA versus HE across all follow-up times (overall P = .04) as was the chair-stand component (overall P < .001). No intervention effects were observed for balance (overall P = .12), 4 m gait speed (overall P = .78), or grip strength (overall P = .62). However, 400 m walking speed was faster in PA versus HE group (overall P =<.001). In separate models, 29% of the rate reduction of major mobility disability in the PA versus HE group was explained by change in SPPB score, while 39% was explained by change in the chair stand component. Lower extremity performance (SPPB) was significantly higher in the PA compared with HE group. Changes in chair-stand score explained a considerable portion of the effect of PA on the reduction of major mobility disability-consistent with the idea that preserving muscle strength/power may be important for the prevention of major mobility disability. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  5. Aerial shows Stennis test stands

    NASA Image and Video Library

    2004-04-16

    An aerial photo shows the B-1/B-2 Test Stand (foreground), A-2 Test Stand (middle) and A-1 Test Stand (back). The historic stands have been used to test engines used on every manned Apollo and space shuttle mission.

  6. 9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1B ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. WEST SIDE, TEST STAND AND SUPERSTRUCTURE. TEST STAND 1-B IN DISTANCE. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  7. Assessing Capabilities of the High Energy Liquid Laser Area Defense System through Combat Simulations

    DTIC Science & Technology

    2008-03-01

    it to strike targets with minimal collateral damage from a range of 15 kilometers. This stand -off type attack, made capable by the ATL, enables...levels they release a photon or quantum of light. This process continues until the light waves ’ strength builds and passes through the medium...mission level model. Lastly these models are classified by durability as standing models, or legacy models. Standing models are legacy models which have

  8. Independent and combined influence of the components of physical fitness on academic performance in youth.

    PubMed

    Esteban-Cornejo, Irene; Tejero-González, Carlos Ma; Martinez-Gomez, David; del-Campo, Juan; González-Galo, Ana; Padilla-Moledo, Carmen; Sallis, James F; Veiga, Oscar L

    2014-08-01

    To examine the independent and combined associations of the components of physical fitness with academic performance among youths. This cross-sectional study included a total of 2038 youths (989 girls) aged 6-18 years. Cardiorespiratory capacity was measured using the 20-m shuttle run test. Motor ability was assessed with the 4×10-m shuttle run test of speed of movement, agility, and coordination. A muscular strength z-score was computed based on handgrip strength and standing long jump distance. Academic performance was assessed through school records using 4 indicators: Mathematics, Language, an average of Mathematics and Language, and grade point average score. Cardiorespiratory capacity and motor ability were independently associated with all academic variables in youth, even after adjustment for fitness and fatness indicators (all P≤.001), whereas muscular strength was not associated with academic performance independent of the other 2 physical fitness components. In addition, the combined adverse effects of low cardiorespiratory capacity and motor ability on academic performance were observed across the risk groups (P for trend<.001). Cardiorespiratory capacity and motor ability, both independently and combined, may have a beneficial influence on academic performance in youth. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Normative Reference of Standing Long Jump for Colombian Schoolchildren Aged 9-17.9 Years: The FUPRECOL Study.

    PubMed

    Ramírez-Vélez, Robinson; Martínez, Martin; Correa-Bautista, Jorge E; Lobelo, Felipe; Izquierdo, Mikel; Rodríguez-Rodríguez, Fernando; Cristi-Montero, Carlos

    2017-08-01

    Ramírez-Vélez, R, Martínez, M, Correa-Bautista, JE, Lobelo, F, Izquierdo, M, Rodríguez-Rodríguez, F, and Cristi-Montero, C. Normative reference of standing long jump for Colombian schoolchildren aged 9-17.9 years: The FUPRECOL study. J Strength Cond Res 31(8): 2083-2090, 2017-The purpose of this study was to generate normative values for the standing long jump (SLJ) test in 9- to 17.9-year olds and to investigate sex and age-group differences. The sample comprised 8,034 healthy Colombian schoolchildren [boys n = 3,488 and girls n = 4,546; mean (SD) age 12.8 (±2.3) years old]. Each participant performed two SLJ. Centile smoothed curves, percentile, and tables for the third, 10th, 25th, 50th, 75th, 90th, and 97th percentiles were calculated using Cole's Lambda-Mu-Sigma method. The 2-way analysis of variance tests and Cohen's d showed that the maximum SLJ (centimeter) was higher in boys than in girls across age groups (p < 0.01), reaching the peak at 13 years. Posthoc analyses within the sexes showed yearly increases in SLJ in all ages. In boys, the 50th percentile SLJ score ranged from 109 to 165 cm. In girls, the 50th percentile jump ranged from 96 to 120 cm. For girls, jump scores increased yearly from age 9 to 12.9 years before reaching a plateau at an age between 13 and 15.9. Our results provide, for the first time, sex- and age-specific SLJ reference values for Colombian schoolchildren aged 9-17.9 years. The normative values presented in this study provide the basis for the determination of the proposed age- and sex-specific standards for the FUPRECOL (Association for Muscular Strength with Early Manifestation of Cardiovascular Disease Risk Factors Among Colombian Children and Adolescents) Study-Physical fitness battery for children and adolescents.

  10. Prediction of in-season shoulder injury from preseason testing in division I collegiate football players.

    PubMed

    Pontillo, Marisa; Spinelli, Bryan A; Sennett, Brian J

    2014-11-01

    Collegiate football is a high-demand sport in which shoulder injuries are common. Research has described the incidence of these injuries, with little focus on causative factors or injury prevention. Football athletes who score lower on preseason strength and functional testing are more likely to sustain an in-season shoulder injury. Prospective, cohort study. Level 2. Twenty-six collegiate football players underwent preseason testing with a rotational profile for shoulder range of motion, isometric strength of the rotator cuff at 90° elevation and external rotation in the 90/90 position, fatigue testing (prone-Y, scaption, and standing cable press), and the Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST). Data collected postseason included the type of shoulder injury and the side injured. Logistic regression was used to determine if the testing measures predicted injury, and a receiver operating characteristic curve was constructed to examine the relationship of CKCUEST to injury. Six athletes sustained shoulder injuries during the season. Predictor variables could significantly predict whether that player would sustain an injury during the season for both the right and left shoulders (P < 0.05). The variables that were significantly correlated with injury of the right side were forward elevation strength, prone-Y to fatigue, and the CKCUEST (P < 0.05); on the left, only the CKCUEST was significant (P < 0.05). The area under the receiver operating characteristic curve for the CKCUEST was 0.86 (ϵ = 0.87, P = 0.01). Using a score of 21 touches, the CKCUEST had a sensitivity of 0.83, a specificity of 0.79, and an odds ratio of 18.75 in determining whether a player sustained a shoulder injury. For this sample, the combination of preseason strength, fatigue, and functional testing was able to identify football players who would sustain a shoulder injury during the season. Using a battery of strength, fatigue, and functional testing may be helpful in identifying football players during preseason who are at a higher risk for sustaining a shoulder injury. This information can be used to optimize preseason testing and implementation of injury prevention programs.

  11. Utilization of bagasse and coconut fibers waste as fillers of sandwich composite for bridge railway sleepers

    NASA Astrophysics Data System (ADS)

    Soehardjo, K. A.; Basuki, A.

    2017-07-01

    The bridge railway sleepers is an essential component in the construction of railways, as the foundation of the rail support in order to withstand the load a train that runs above it. Sleepers used in bridge construction are expected to have a longer service life, lighter weight and durable so that can be used more efficient. This research was carried out to create a model of bridges railway sleepers made of sandwich structured composite from fiber glass, epoxy resin with fillers waste of bagasse (sugar cane pulp mill) or coconut fiberboard (copra industry) that using polyurethane as an adhesive. The process of making was conditioned for small and medium industrial applications. Railway sleepers’ specifications adapted to meet the requirements of end user. The process steps in this research include; lay-up fiberglass combined with bagasse/coconut fiberboard (as fillers), gluing with epoxy resin, molded it with pressure to be solid, curing after solidification process. The specimens of composite, bagasse and coconut fiber board were tested for tensile and compressive strength. The prototype were tested of mechanical test: flexural moment test to the stand rail, flexural moment test to the middle of the sleepers and tensile strength test on one side of the sleepers, in accordance to SNI 11-3388-1994 Method testing of single block concrete sleepers and bearing single rail fastening systems. The results of mechanical testing all variations meet the technical specifications of end user such as test results for flexural moment on all prototypes, after load test, there is no visible crack. While in the tensile strength test, it seem the prototype with coconut fiberboard filler, shows better performance than bagasse fiberboard filler, the decisions is just depended on techno economic and lifetime.

  12. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  13. An examination of the challenges influencing science instruction in Florida elementary classrooms

    NASA Astrophysics Data System (ADS)

    North, Stephanie Gwinn

    It has been shown that the mechanical properties of thin films tend to differ from their bulk counterparts. Specifically, the bulge and microtensile testing of thin films used in MEMS have revealed that these films demonstrate an inverse relationship between thickness and strength. A film dimension is not a material property, but it evidently does affect the mechanical performance of materials at very small thicknesses. A hypothetical explanation for this phenomenon is that as the thickness dimension of the film decreases, it is statistically less likely that imperfections exist in the material. It would require a very small thickness (or volume) to limit imperfections in a material, which is why this phenomenon is seen in films with thicknesses on the order of 100 nm to a few microns. Another hypothesized explanation is that the surface tension that exists in bulk material also exists in thin films but has a greater impact at such a small scale. The goal of this research is to identify a theoretical prediction of the strength of thin films based on its microstructural properties such as grain size and film thickness. This would minimize the need for expensive and complicated tests such as the bulge and microtensile tests. In this research, data was collected from the bulge and microtensile testing of copper, aluminum, gold, and polysilicon free-standing thin films. Statistical testing of this data revealed a definitive inverse relationship between thickness and strength, as well as between grain size and strength, as expected. However, due to a lack of a standardized method for either test, there were significant variations in the data. This research compares and analyzes the methods used by other researchers to develop a suggested set of instructions for a standardized bulge test and standardized microtensile test. The most important parameters to be controlled in each test were found to be strain rate, temperature, film deposition method, film length, and strain measurement.

  14. Testing resonating vector strength: Auditory system, electric fish, and noise

    NASA Astrophysics Data System (ADS)

    Leo van Hemmen, J.; Longtin, André; Vollmayr, Andreas N.

    2011-12-01

    Quite often a response to some input with a specific frequency ν○ can be described through a sequence of discrete events. Here, we study the synchrony vector, whose length stands for the vector strength, and in doing so focus on neuronal response in terms of spike times. The latter are supposed to be given by experiment. Instead of singling out the stimulus frequency ν○ we study the synchrony vector as a function of the real frequency variable ν. Its length turns out to be a resonating vector strength in that it shows clear maxima in the neighborhood of ν○ and multiples thereof, hence, allowing an easy way of determining response frequencies. We study this "resonating" vector strength for two concrete but rather different cases, viz., a specific midbrain neuron in the auditory system of cat and a primary detector neuron belonging to the electric sense of the wave-type electric fish Apteronotus leptorhynchus. We show that the resonating vector strength always performs a clear resonance correlated with the phase locking that it quantifies. We analyze the influence of noise and demonstrate how well the resonance associated with maximal vector strength indicates the dominant stimulus frequency. Furthermore, we exhibit how one can obtain a specific phase associated with, for instance, a delay in auditory analysis.

  15. Combined exercise is more effective than aerobic exercise in the improvement of fall risk factors: a randomized controlled trial in community-dwelling older men.

    PubMed

    Sousa, Nelson; Mendes, Romeu; Silva, André; Oliveira, José

    2017-04-01

    To compare the long-term effects of two community-based exercise programs on fall risk factors, such as balance, postural control, mobility and leg strength, in community-dwelling older men. Single-blinded randomized controlled trial, comparing three groups, with follow-ups at eight, 16, 24 and 32 weeks. Older men independent-living residing in Maia city, Portugal. A total of 66 older men (aged 69.0 ±4.9 years) were randomly assigned to an aerobic exercise group ( n = 22), a combined aerobic and resistance exercise group ( n = 22) or a control group ( n = 22). Both community-based exercise programs consisted of three sessions each week for 32 consecutive weeks and were planned for moderate-to-vigorous intensity. The control group had no exercise intervention. Main outcomes were measured by the Timed Up and Go Test, functional reach test, 30-second chair stand test and 6-minute walk test, on five different occasions. Repeated measures of analysis of covariance revealed significant main effects between time × group interaction in all outcomes over time (Timed Up and Go Test: p < 0.001; functional reach test: p = 0.002; 30-second chair stand: p = 0.001; 6-minute walk test: p < 0.001). Both exercise groups reported improvements; however, better performance was identified in the combined aerobic and resistance exercise group compared with the aerobic exercise group (-20.3% vs. -9.1% on the Timed Up and Go Test, +27.5% vs. +10.9% on the functional reach test, +20.8% vs. +7.3% on 30-second chair stand, +10.9% vs. +3.5% on 6-minute walk test). Adding resistance exercise to aerobic exercise improves factors associated with an increased risk of falls. However, both exercise regimes, combined or aerobic alone, are more effective than no exercise in the reduction of fall risk factors. ClinicalTrials.org #NCT01874132.

  16. Treadmill Training with Virtual Reality Improves Gait, Balance, and Muscle Strength in Children with Cerebral Palsy.

    PubMed

    Cho, Chunhee; Hwang, Wonjeong; Hwang, Sujin; Chung, Yijung

    2016-03-01

    Independent walking is an important goal of clinical and community-based rehabilitation for children with cerebral palsy (CP). Virtual reality-based rehabilitation therapy is effective in motivating children with CP. This study investigated the effects of treadmill training with virtual reality on gait, balance, muscular strength, and gross motor function in children with CP. Eighteen children with spastic CP were randomly divided into the virtual reality treadmill training (VRTT) group (9 subjects, mean age, 10.2 years) and treadmill training (TT) group (9 subjects, mean age, 9.4 years). The groups performed their respective programs as well as conventional physical therapy 3 times/week for 8 weeks. Muscle strength was assessed using a digitalized manual muscle tester. Gross motor function was assessed using the Gross Motor Functional Measure (GMFM). Balance was assessed using the Pediatric Balance Scale (PBS). Gait speed was assessed using the 10-meter walk test (10MWT), and gait endurance was assessed using the 2-minute walk test (2MWT). After training, gait and balance was improved in the VRTT compared to the TT group (P < 0.05). Muscular strength was significantly greater in the VRTT group than the TT group, except for right hamstring strength. The improvements in GMFM (standing) and PBS scores were greater in the VRTT group than the TT group (P < 0.05). Furthermore, the VRTT group showed the higher values of 10MWT and 2MWT compared to the TT group (P < 0.05). In conclusion, VRTT programs are effective for improving gait, balance, muscular strength, and gross motor function in children with CP.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cabrera-Palmer, Belkis

    Predicting the performance of radiation detection systems at field sites based on measured performance acquired under controlled conditions at test locations, e.g., the Nevada National Security Site (NNSS), remains an unsolved and standing issue within DNDO’s testing methodology. Detector performance can be defined in terms of the system’s ability to detect and/or identify a given source or set of sources, and depends on the signal generated by the detector for the given measurement configuration (i.e., source strength, distance, time, surrounding materials, etc.) and on the quality of the detection algorithm. Detector performance is usually evaluated in the performance and operationalmore » testing phases, where the measurement configurations are selected to represent radiation source and background configurations of interest to security applications.« less

  18. HEAVY MANUAL WORK THROUGHOUT THE WORKING LIFETIME AND MUSCLE STRENGTH AMONG MEN AT RETIREMENT AGE

    PubMed Central

    Walker-Bone, K; D’Angelo, S; Syddall, HE; Palmer, KT; Cooper, C; Coggon, D; Sayer, AA

    2016-01-01

    Introduction Reductions in heavy manual work as a consequence of mechanisation might impact adversely on muscle strength at older ages. We investigated the association between grip strength at retirement age and lifetime occupational exposure to physically demanding activities. Grip strength is an important predictor of long-term health and physical function in older people. Methods Grip strength (maximum of three readings in each hand) was measured in men from the Hertfordshire Cohort Study at a single examination when their mean age was 65.8 (SD 2.9) years. Associations with lifetime occupational exposure (ascertained by questionnaire) to three activities (standing/walking ≥4 hours/day; lifting ≥25 kg; and energetic work sufficient to induce sweating) were assessed by multivariable linear regression with adjustment for various potential confounders. Results Complete data were available from 1,418 men who had worked for at least 20 years. After adjustment for age, height and weight, those with longer exposures to walking/standing and heavy lifting had lower grip strength, but the relationship disappeared after further adjustment for confounders. Working at physical intensity sufficient to induce sweating was not significantly associated with grip strength. Conclusions We found no evidence that physically demanding occupational activities increase hand grip strength at normal retirement age. Any advantages of regular physical occupational activity may have been obscured by unmeasured socio-economic confounders. PMID:26896253

  19. The impact of dynamic balance measures on walking performance in multiple sclerosis

    PubMed Central

    Fritz, Nora E.; Marasigan, Rhul Evans R.; Calabresi, Peter A.; Newsome, Scott D.; Zackowski, Kathleen M.

    2014-01-01

    Background Static posture imbalance and gait dysfunction are common in individuals with multiple sclerosis (MS). Although the impact of strength and static balance on walking has been examined, little is known about the impact of dynamic standing balance on walking in MS. Objective To determine the impact of dynamic balance, static balance, sensation, and strength measures to walking in individuals with MS. Methods 52 individuals with MS (27 females; 26 relapsing-remitting; mean age 45.6±10.3 years; median EDSS 3.5 (range 0-7) participated in testing for dynamic and static posturography (Kistler 9281 force plate), hip flexion, hip extension, and ankle dorsiflexion strength (Microfet2 hand-held dynamometer), sensation (Vibratron II) and walk velocity (Optotrak Motion Analysis System). Mann-Whitney tests, Spearman correlation coefficients, and forward stepwise multiple regression were used to assess statistical significance. Results All measures were significantly abnormal in MS subjects when compared to age and sex-matched norms (p<0.05 for all). Static balance (eyes open, feet together [EOFT]), anterior- posterior (AP) dynamic sway, and hip extension strength were strongly correlated with fast walking velocity (AP sway r=0.68; hip extension strength r=0.73; EOFT r=-0.40). Together, AP dynamic sway (ρr=0.71, p<0.001), hip extension strength (ρr=0.54, p<0.001), and EOFT static balance (ρr=-0.41, p=0.01) explained more than 70% of the variance in fast walking velocity (p<0.001). Conclusions These data suggest that AP dynamic sway impacts walking performance in MS. A combined evaluation of dynamic balance, static balance and strength may lead to a better understanding of walking mechanisms as well as the development of strategies to improve walking. PMID:24795162

  20. Physical tests for patient selection for bone mineral density measurements in postmenopausal women.

    PubMed

    Kärkkäinen, Matti; Rikkonen, Toni; Kröger, Heikki; Sirola, Joonas; Tuppurainen, Marjo; Salovaara, Kari; Arokoski, Jari; Jurvelin, Jukka; Honkanen, Risto; Alhava, Esko

    2009-04-01

    There is a need for cost-effective clinical methods to select women for bone densitometry. The aim of the present study was to determine whether relatively simple and clinically applicable physical tests could be useful in prediction of bone density in postmenopausal women. A total of 606 women (age range 66-71 years) taking part in the population based OSTPRE Fracture Prevention Study were investigated. Spinal and femoral bone mineral density (BMD) was measured by Dual X-ray Absorptiometry (DXA). Physical tests included the standing-on-one-foot (SOOF), grip strength (GS), leg extension strength, ability to squat down, standing 10 s eyes closed, chair rising, regular walk for 10 m and tandem walk for 6 m. All linear regression models were adjusted for age, body mass index, years on hormone therapy, years since menopause, current smoking and use of oral glucocorticoids. The SOOF was associated with lumbar spine BMD (r2=0.16, p=0.004) and the femoral regions (r2 values from 0.17 to 0.23 and p-values all<0.001). The GS was associated with lumbar spine BMD (r2=0.16, p=0.011) and the femoral regions (r2 values from 0.16 to 0.21 and p-values from <0.001 to 0.004). The ability to squat down on the floor was associated with the femoral regions (r2 values from 0.15 to 0.21 and p-values from 0.028 to 0.040). In addition, functional capacity was decreased in women with femoral neck osteoporosis (WHO classification) compared to women with normal or osteopenic BMD: SOOF -39% (p=0.001), GS -18% (p<0.001), leg extension strength -19% (p=0.007) and ability to squat down on the floor -40% (p=0.004). For osteoporosis prediction (ROC analysis) a threshold of a 22 kg in GS would yield a true-positive rate (sensitivity) of about 58% and a true-negative rate (specificity) of 86% (AUC 0.76). We suggest that grip strength could be used in medical decision making to identify those women who would benefit from BMD measurements albeit alone it may not provide accurate enough tool for osteoporosis screening.

  1. Association Between Physical Activity Intensity and Physical Capacity Among Individuals Awaiting Bariatric Surgery.

    PubMed

    Rioux, Brittany V; Sénéchal, Martin; Kwok, Karen; Fox, Jill; Gamey, Dean; Bharti, Neha; Vergis, Ashley; Hardy, Krista; Bouchard, Danielle R

    2017-05-01

    Physical activity is a routine component of the lifestyle modification program implemented prior to bariatric surgery, and one of the goals is to improve patients' physical capacity. However, the physical activity intensity recommended to meet that goal is unknown. This study aimed to assess the association between time spent at different physical activity intensities and physical capacity in patients awaiting bariatric surgery. A total of 39 women and 13 men were recruited. The primary outcome was physical capacity measured using six objective tests: 6-min walk, chair stand, sit and reach, unipodal balance (eyes open and eyes closed), and hand grip strength tests. The primary exposure variable was physical activity intensity (i.e., sedentary, light, moderate, and vigorous) measured by accelerometers. The average body mass index was 46.3 ± 5.4 kg/m 2 . Only 6% of total time was spent at moderate to vigorous intensity, while 71% of the time was spent sedentary. When adjusted for body mass index, age, and sex, four of the six physical capacity tests were significantly associated with moderate intensity physical activity β(SE): 6-min walk 9.7 (2.7), chair stand 0.3 (0.1), balance (eyes open) 1.8 (0.7), and hand grip strength 1.2 (0.4), and only the 6-min walk was associated with sedentary activity 1.7 (0.7). These results suggest that physical capacity is associated with time spent at moderate intensity in individuals awaiting bariatric surgery. The next step is to study if an increase in time spent at moderate intensity will translate to improvements in physical capacity.

  2. Wii-Workouts on Chronic Pain, Physical Capabilities and Mood of Older Women: A Randomized Controlled Double Blind Trial.

    PubMed

    Monteiro-Junior, Renato Sobral; de Souza, Cíntia Pereira; Lattari, Eduardo; Rocha, Nuno Barbosa Ferreira; Mura, Gioia; Machado, Sérgio; da Silva, Elirez Bezerra

    2015-01-01

    Chronic Low Back Pain (CLBP) is a public health problem and older women have higher incidence of this symptom, which affect body balance, functional capacity and behavior. The purpose of this study was to verifying the effect of exercises with Nintendo Wii on CLBP, functional capacity and mood of elderly. Thirty older women (68 ± 4 years; 68 ± 12 kg; 154 ± 5 cm) with CLBP participated in this study. Elderly individuals were divided into a Control Exercise Group (n = 14) and an Experimental Wii Group (n = 16). Control Exercise Group did strength exercises and core training, while Experimental Wii Group did ones additionally to exercises with Wii. CLBP, balance, functional capacity and mood were assessed pre and post training by the numeric pain scale, Wii Balance Board, sit to stand test and Profile of Mood States, respectively. Training lasted eight weeks and sessions were performed three times weekly. MANOVA 2 x 2 showed no interaction on pain, siting, stand-up and mood (P = 0.53). However, there was significant difference within groups (P = 0.0001). ANOVA 2 x 2 showed no interaction for each variable (P > 0.05). However, there were significant differences within groups in these variables (P < 0.05). Tukey's post-hoc test showed significant difference in pain on both groups (P = 0.0001). Wilcoxon and Mann-Whitney tests identified no significant differences on balance (P > 0.01). Capacity to Sit improved only in Experimental Wii Group (P = 0.04). In conclusion, physical exercises with Nintendo Wii Fit Plus additional to strength and core training were effective only for sitting capacity, but effect size was small.

  3. Design prediction for long term stress rupture service of composite pressure vessels

    NASA Technical Reports Server (NTRS)

    Robinson, Ernest Y.

    1992-01-01

    Extensive stress rupture studies on glass composites and Kevlar composites were conducted by the Lawrence Radiation Laboratory beginning in the late 1960's and extending to about 8 years in some cases. Some of the data from these studies published over the years were incomplete or were tainted by spurious failures, such as grip slippage. Updated data sets were defined for both fiberglass and Kevlar composite stand test specimens. These updated data are analyzed in this report by a convenient form of the bivariate Weibull distribution, to establish a consistent set of design prediction charts that may be used as a conservative basis for predicting the stress rupture life of composite pressure vessels. The updated glass composite data exhibit an invariant Weibull modulus with lifetime. The data are analyzed in terms of homologous service load (referenced to the observed median strength). The equations relating life, homologous load, and probability are given, and corresponding design prediction charts are presented. A similar approach is taken for Kevlar composites, where the updated stand data do show a turndown tendency at long life accompanied by a corresponding change (increase) of the Weibull modulus. The turndown characteristic is not present in stress rupture test data of Kevlar pressure vessels. A modification of the stress rupture equations is presented to incorporate a latent, but limited, strength drop, and design prediction charts are presented that incorporate such behavior. The methods presented utilize Cartesian plots of the probability distributions (which are a more natural display for the design engineer), based on median normalized data that are independent of statistical parameters and are readily defined for any set of test data.

  4. Not All Is Lost: Old Adults Retain Flexibility in Motor Behaviour during Sit-to-Stand

    PubMed Central

    Greve, Christian; Zijlstra, Wiebren; Hortobágyi, Tibor; Bongers, Raoul M.

    2013-01-01

    Sit-to-stand is a fundamental activity of daily living, which becomes increasingly difficult with advancing age. Due to severe loss of leg strength old adults are required to change the way they rise from a chair and maintain stability. Here we examine whether old compared to young adults differently prioritize task-important performance variables and whether there are age-related differences in the use of available motor flexibility. We applied the uncontrolled manifold analysis to decompose trial-to-trial variability in joint kinematics into variability that stabilizes and destabilizes task-important performance variables. Comparing the amount of variability stabilizing and destabilizing task-important variables enabled us to identify the variable of primary importance for the task. We measured maximal isometric voluntary force of three muscle groups in the right leg. Independent of age and muscle strength, old and young adults similarly prioritized stability of the ground reaction force vector during sit-to-stand. Old compared to young adults employed greater motor flexibility, stabilizing ground reaction forces during sit-to-sand. We concluded that freeing those degrees of freedom that stabilize task-important variables is a strategy used by the aging neuromuscular system to compensate for strength deficits. PMID:24204952

  5. Advanced Gas Turbine (AGT): Power-train system development

    NASA Technical Reports Server (NTRS)

    Helms, H. E.; Johnson, R. A.; Gibson, R. K.; Smith, L. B.

    1983-01-01

    Technical work on the design and effort leading to the testing of a 74.5 kW (100 hp) automotive gas turbine is described. The general effort was concentrated on building an engine for test starting in July. The buildup progressed with only routine problems and the engine was delivered to the test stand 9 July. In addition to the engine build effort, work continued in selected component areas. Ceramic turbine parts were built and tested. Burst tests of ceramic rotors show strengths are approaching that achieved in test bars; proof testing is required for acceptable strength ceramic vanes. Over 25 hours was accumulated on the combustor rig in three test modes: pilot nozzle only, start nozzle, and main nozzle operation. Satisfactory ignition was achieved for a wide range of starting speeds and the lean blowout limit was as low as 0.06 kg/b (0.14 lb/hr). Lean blowout was more a function of nozzle atomization than fuel/air ratio. A variety of cycle points were tested. Transition from start nozzle flow to main nozzle flow was done manually without difficulty. Regenerator parts were qualification tested without incident and the parts were assembled on schedule. Rig based performance matched first build requirements. Repeated failures in the harmonic drive gearbox during rig testing resulted in that concept being abandoned for an alternate scheme.

  6. The Effects of Extravehicular Activity (EVA) Glove Pressure on Hand Strength

    NASA Technical Reports Server (NTRS)

    Rajulu, Sudhakar; Mesloh, Miranda; Thompson, Shelby; England, Scott; Benson, Liz

    2009-01-01

    With the new vision of space travel aimed at traveling back to the Moon and eventually to Mars, NASA is designing a new spacesuit glove. The purpose of this study was to baseline hand strength while wearing the current Extravehicular Activity (EVA) glove, the Phase VI. By varying the pressure in the glove, hand strength could be characterized as a function of spacesuit pressure. This finding is of extreme importance when evaluating missions that require varying suit pressures associated with different operations within NASA's current human spaceflight program, Constellation. This characterization fed directly into the derivation of requirements for the next EVA glove. This study captured three types of maximum hand strength: grip, lateral pinch, and pulp-2 pinch. All three strengths were measured under varying pressures and compared to a bare-hand condition. The resulting standardized data was reported as a percentage of the bare-hand strength. The first wave of tests was performed while the subjects, four female and four male, were wearing an Extravehicular Mobility Unit (EMU) suit supported by a suit stand. This portion of the test collected data from the barehand, suited unpressurized, and suited pressurized (4.3 psi) conditions. In addition, the effects of the Thermal Micrometeoroid Garment (TMG) on hand strength were examined, with the suited unpressurized and pressurized cases tested with and without a TMG. It was found that, when pressurized and with the TMG, the Phase VI glove reduced applied grip strength to a little more than half of the subject s bare-hand strength. The lateral pinch strength remained relatively constant while the pulp-2 pinch strength actually increased with pressure. The TMG was found to decrease maximum applied grip strength by an additional 10% for both pressurized and unpressurized cases, while the pinch strengths saw little to no change. In developing requirements based on human subjects, it is important to attempt to derive results that encompass the variation within the entire population. The current EMU does not accommodate humans at the extremes of the anthropometric spectrum. To account for this and to ensure that these requirements cover the population, another phase of testing will be conducted in a differential pressure glove box. This phase will focus on smaller females and very large males that do not have a properly fitted EMU suit. Instead, they would wear smaller or larger gloves and be tested in the glove box as a means to compare and contrast their strength capabilities against the EMU accommodated hand size subjects. The glove box s ability to change pressures easily will also allow for a wider range of glove pressures to be tested. Compared to the data collected on the subjects wearing the EMU suit, it is expected that there will be similar ratios to bare-hand. It is recommended that this topic be sent to the Physical Ergonomics Board for review.

  7. Comparisons: Technical-Tactical and Time-Motion Analysis of Mixed Martial Arts by Outcomes.

    PubMed

    Miarka, Bianca; Vecchio, Fabrício B D; Camey, Suzi; Amtmann, John A

    2016-07-01

    Miarka, B, Vecchio, FBD, Camey, S, and Amtmann, JA. Comparisons: technical-tactical and time-motion analysis of mixed martial arts by outcomes. J Strength Cond Res 30(7): 1975-1984, 2016-The aim of this study was to compare time-motion and technical-tactical analysis between paired outcomes and rounds of mixed martial arts (MMA) matches. The sample consisted of 645 rounds of MMA competition paired by outcomes (first round, winners n = 215 and losers n = 215; second round, winners n = 215 and losers n = 215; third round, winners n = 215 and losers n = 215). The time-motion variables were categorized into low-intensity or high-intensity, stand-up or groundwork situations. Stand-up techniques were analyzed by observing total strikes to the head and body, and takedowns. The actions on the ground were analyzed by observing submission activity, including successful choking and joint locking actions, and also positional improvements, including advances to the mount, half guard, and side and back positions. Chi-squared and Wilcoxon tests were conducted with a significance level of p ≤ 0.05. Results showed that winners had higher values for total strikes and submissions in all rounds, and also positional improvements, over losers. The standing combat with low-intensity comparisons presented differences between the rounds first, with a median of 2:33.5 (P25-P75%: 1:20-3:56) minute, second, with 2:37 (1:24-3:59) minute, and third, with 2:07 (1:06-3:39.2) minute. These data suggest a focus on the intermittent demand presented in combat phases with a special attention to the strike and ground technical-tactical skills; strength and conditioning coaches could emphasize the effort pause ratios for both standing and ground combat that mimic the requirements of MMA, especially during the third round.

  8. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios.

    PubMed

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-10-18

    To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines.

  9. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios

    PubMed Central

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-01-01

    AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). CONCLUSION: According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines. PMID:26495249

  10. Whole-body vibration training improves balance, muscle strength and glycosylated hemoglobin in elderly patients with diabetic neuropathy.

    PubMed

    Lee, Kyoungjin; Lee, Seungwon; Song, Changho

    2013-12-01

    Elderly patients with diabetes and peripheral neuropathy are more likely to experience falls. However, the information available on how such falls can be prevented is scarce. We investigated the effects of whole-body vibration (WBV) combined with a balance exercise program on balance, muscle strength, and glycosylated hemoglobin (HbA1c) in elderly patients with diabetic peripheral neuropathy. Fifty-five elderly patients with diabetic neuropathy were randomly assigned to WBV with balance exercise group, balance exercise (BE) group, and control group. The WBV and BE groups performed the balance exercise program for 60 min per day, 2 times per week, for 6 weeks. Further, the WBV group performed WBV training (up to 3 × 3 min, 3 times per week, for 6 weeks). The control group did not participate in any training. The main outcome measures were assessed at baseline and after 6 weeks of training; namely, we assessed the postural sway and one leg stance (OLS) for static balance; Berg balance scale (BBS), timed up-and-go (TUG) test, and functional reach test (FRT) for dynamic balance; five-times-sit-to-stand (FTSTS) test for muscle strength; and HbA1c for predicting the progression of diabetes. Significant improvements were noted in the static balance, dynamic balance, muscle strength, and HbA1c in the WBV group, compared to the BE and control groups (P < 0.05). Thus, in combination with the balance exercise program, the short-term WBV therapy is beneficial in improving balance, muscle strength and HbA1c, in elderly patients with diabetic neuropathy who are at high risk for suffering falls.

  11. Vitamin D status and physical function in older Finnish people: A one-year follow-up study.

    PubMed

    Salminen, Marika; Saaristo, Pilvi; Salonoja, Maritta; Vaapio, Sari; Vahlberg, Tero; Lamberg-Allardt, Christel; Aarnio, Pertti; Kivelä, Sirkka-Liisa

    2015-01-01

    The aim was to describe vitamin D status and its association with changes in PF during 12 months in Finnish community-dwelling elderly (≥65 years). Baseline serum 25-hydroxyvitamin D (25OHD) concentration was measured by enzymeimmunoassay, and participants (n=518) were divided according to 25OHD to three groups (I <50 nmol/l, II 50-74.9 nmol/l, and III ≥75 nmol/l). PF (maximal isometric extension strength of right and left knee, and time in five-repetition sit-to-stand test (5STS) and 10-m walking test) was measured at baseline and after 12 months. 25OHD deficiency (<50 nmol/l) was found in 20.5% of the participants. During a 12-month follow-up, differences in changes in knee extensor strength of right (p=0.044) and left (p=0.010) lower extremity and in 10-m walking test (p=.040) between the groups were significant. According to further pairwise comparisons these differences were between groups I and III (right knee, p=0.036; left knee, p=0.009; 10-m walk, p=0.044), with the exception of left knee extensor strength in which there were also significant difference between groups I and II (p=0.039). All significant differences in changes were in favour of group II or III. Significant differences in changes in knee extensor strengths maintained after adjustments for group (intervention/control), parathyroid hormone, and baseline level of knee extensor strength. Prospective analyses showed low 25OHD concentrations (<50 nmol/l) to be associated with deterioration in PF during 12 months compared with high 25OHD concentrations (≥75 nmol/l). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Relation between isokinetic muscle strength and functional capacity in recreational athletes with chondromalacia patellae.

    PubMed

    Yildiz, Y; Aydin, T; Sekir, U; Cetin, C; Ors, F; Alp Kalyon, T

    2003-12-01

    To investigate the effects of isokinetic exercise on pain and functional test scores of recreational athletes with chondromalacia patellae (CMP) and to examine the correlation between isokinetic parameters and functional tests or pain score. The functional ability of 30 recreational athletes with unilateral CMP was evaluated using six different tests. Pain scores were assessed during daily activities before and after the treatment protocol. Isokinetic exercise sessions were carried out at angular velocities of 60 degrees /s (25-90 degrees range of flexion) and 180 degrees /s (full range). These sessions were repeated three times a week for six weeks. Quadriceps and hamstring peak torque, total work, and endurance ratios had improved significantly after the treatment, as did the functional parameters and pain scores. There was a poor correlation between the extensor endurance ratio and one leg standing test. A moderate correlation between the visual analogue scale and the extensor endurance ratio or flexion endurance ratio was also found. The isokinetic exercise programme used in this study had a positive effect on muscle strength, pain score, and functional ability of knees with CMP. The improvement in the functional capacity did not correlate with the isokinetic parameters.

  13. 2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. EAST ELEVATION OF POWER PLANT TEST STAND (HORIZONTAL TEST STAND REMNANTS OF BUILDING-BLANK WHITE WALL ONLY ORIGINAL REMAINS. - Marshall Space Flight Center, East Test Area, Power Plant Test Stand, Huntsville, Madison County, AL

  14. Serum cystatin C level is associated with locomotive syndrome risk and can be an early predictor in community-living people: The Yakumo study.

    PubMed

    Tanaka, Satoshi; Ando, Kei; Kobayashi, Kazuyoshi; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Machino, Masaaki; Ota, Kyotaro; Seki, Taisuke; Suzuki, Koji; Nishida, Yoshihiro; Ishiguro, Naoki; Hasegawa, Yukiharu; Imagama, Shiro

    2018-03-02

    The locomotive syndrome (LS) risk has been recently proposed as a criterion for evaluating physical ability. Serum cystatin C level is an early renal function marker and a cardiovascular disease predictor. This study aimed to evaluate the relationship between serum cystatin C level and LS risk. We enrolled 54 participants and conducted the two-step test, stand-up test, 25-question geriatric locomotive function scale, LS risk test, Timed Up and Go test, back muscle strength, grip strength, blood test and serum cystatin C level measurement. A comparative study was conducted in participants with and without LS risk and in subgroups aged <60 and ≥60 years. No significant difference was found in the serum cystatin C level in subgroups aged <60 years and without LS risk. However, it was significantly higher in subjects with LS risk and aged ≥60 years. The area under the curve of the serum cystatin C level for LS risk was 0.824. The serum cystatin C level is significantly related to LS risk and can be an early predictor. In middle-aged and elderly people with high serum cystatin C levels, it is strongly recommended to enforce LS risk test and intervention.

  15. Evaluation of Geopolymer Concrete for Rocket Test Facility Flame Deflectors

    NASA Technical Reports Server (NTRS)

    Allgood, Daniel C.; Montes, Carlos; Islam, Rashedul; Allouche, Erez

    2014-01-01

    The current paper presents results from a combined research effort by Louisiana Tech University (LTU) and NASA Stennis Space Center (SSC) to develop a new alumina-silicate based cementitious binder capable of acting as a high performance refractory material with low heat ablation rate and high early mechanical strength. Such a binder would represent a significant contribution to NASA's efforts to develop a new generation of refractory 'hot face' liners for liquid or solid rocket plume environments. This project was developed as a continuation of on-going collaborations between LTU and SSC, where test sections of a formulation of high temperature geopolymer binder were cast in the floor and walls of Test Stand E-1 Cell 3, an active rocket engine test stand flame trench. Additionally, geopolymer concrete panels were tested using the NASA-SSC Diagnostic Test Facility (DTF) thruster, where supersonic plume environments were generated on a 1ft wide x 2ft long x 6 inch deep refractory panel. The DTF operates on LOX/GH2 propellants producing a nominal thrust of 1,200 lbf and the combustion chamber conditions are Pc=625psig, O/F=6.0. Data collected included high speed video of plume/panel area and surface profiles (depth) of the test panels measured on a 1-inch by 1-inch giving localized erosion rates during the test. Louisiana Tech conducted a microstructure analysis of the geopolymer binder after the testing program to identify phase changes in the material.

  16. A Scoping Review of Physical Performance Outcome Measures Used in Exercise Interventions for Older Adults With Alzheimer Disease and Related Dementias.

    PubMed

    McGough, Ellen L; Lin, Shih-Yin; Belza, Basia; Becofsky, Katie M; Jones, Dina L; Liu, Minhui; Wilcox, Sara; Logsdon, Rebecca G

    2017-11-28

    There is growing evidence that exercise interventions can mitigate functional decline and reduce fall risk in older adults with Alzheimer disease and related dementias (ADRD). Although physical performance outcome measures have been successfully used in older adults without cognitive impairment, additional research is needed regarding their use with individuals who have ADRD, and who may have difficulty following instructions regarding performance of these measures. The purpose of this scoping review was to identify commonly used physical performance outcome measures, for exercise interventions, that are responsive and reliable in older adults with ADRD. Ultimately, we aimed to provide recommendations regarding the use of outcome measures for individuals with ADRD across several domains of physical performance. A scoping review was conducted to broadly assess physical performance outcome measures used in exercise interventions for older adults with ADRD. Exercise intervention studies that included at least 1 measure of physical performance were included. All physical performance outcome measures were abstracted, coded, and categorized into 5 domains of physical performance: fitness, functional mobility, gait, balance, and strength. Criteria for recommendations were based on (1) the frequency of use, (2) responsiveness, and (3) reliability. Frequency was determined by the number of studies that used the outcome measure per physical performance domain. Responsiveness was assessed via calculated effect size of the outcome measures across studies within physical performance domains. Reliability was evaluated via published studies of psychometric properties. A total of 20 physical performance outcome measures were extracted from 48 articles that met study inclusion criteria. The most frequently used outcome measures were the 6-minute walk test, Timed Up and Go, repeated chair stand tests, short-distance gait speed, the Berg Balance Scale, and isometric strength measures. These outcome measures demonstrated a small, medium, or large effect in at least 50% of the exercise intervention studies. Good to excellent reliability was reported in samples of older adults with mild to moderate dementia. Fitness, functional mobility, gait, balance, and strength represent important domains of physical performance for older adults. The 6-minute walk test, Timed Up and Go, repeated chair stand tests, short-distance gait speed, Berg Balance Scale, and isometric strength are recommended as commonly used and reliable physical performance outcome measures for exercise interventions in older adults with mild to moderate ADRD. Further research is needed on optimal measures for individuals with severe ADRD. The results of this review will aid clinicians and researchers in selecting reliable measures to evaluate physical performance outcomes in response to exercise interventions in older adults with ADRD.

  17. Nondestructive evaluation of standing trees with a stress wave method.

    Treesearch

    Xiping Wang; Robert J. Ross; Michael McClellan; R. James Barbour; John R. Erickson; John W. Forsman; Gary D. McGinnis

    2001-01-01

    The primary objective of this study was to investigate the usefulness of a stress wave technique for evaluating wood strength and stiffness of young-growth western hemlock and Sitka spruce in standing trees. A secondary objective was to determine if the effects of silvicultural practices on wood quality can be identified using this technique. Stress wave measurements...

  18. Strength and stiffness assessment of standing trees using a nondestructive stress wave technique.

    Treesearch

    Xiping Wang; Robert J. Ross; Michael McClellan; R. James Barbour; John R. Erickson; John W. Forsman; Gary D. McGinnis

    Natureas engineering of wood through genetics, stand conditions, and environment creates wide variability in wood as a material, which in turn introduces difficulties in wood processing and utilization. Manufacturers sometimes find it difficult to consistently process wood into quality products because of its wide range of properties. The primary objective of this...

  19. Silvicultural methods for regenerating oaks

    Treesearch

    F. Bryan Clark; Richard F. Watt

    1971-01-01

    Advance reproduction is the key to forming the new oak stand. However, the size or strength of the advance stems is just as important as number. Most oak stands approaching maturity have enough advance reproduction, but many do not. In such cases, harvest cuttings must be delayed and overstory densities regulated to favor the establishment and development of new oaks...

  20. Sit-to-Stand Movement in Children with Cerebral Palsy: A Critical Review

    ERIC Educational Resources Information Center

    dos Santos, Adriana Neves; Pavao, Silvia Leticia; Rocha, Nelci Adriana Cicuto Ferreira

    2011-01-01

    Sit-to-stand (STS) movement is widely performed in daily life and an important pre requisite for acquisition of functional abilities. However, STS is a biomechanical demanding task which requires high levels of neuromuscular coordination, muscle strength and postural control. As children with cerebral palsy (CP) exhibit a series of impairments in…

  1. Resistance Training Improves Muscle Function and Cardiometabolic Risks But Not Quality of Life in Older People With Type 2 Diabetes Mellitus: A Randomized Controlled Trial.

    PubMed

    Hsieh, Ping-Lun; Tseng, Chin-Hsiao; Tseng, Yufeng Jane; Yang, Wei-Shiung

    In older people with type 2 diabetes mellitus (T2DM), the effects of aging and T2DM may compromise the function of skeletal muscle, deteriorate metabolic status, and jeopardize physical performance, aerobic capacity, and quality of life (QoL). The purpose of this study was to investigate the effects of 12 weeks of resistance training (RT) on muscle function, physical performance, cardiometabolic risks, and QoL in older people with T2DM. This study was a randomized controlled trial that employed block randomization, assessor blinding, and the intention-to-treat principle. Thirty people 65 years or older with a diagnosis of T2DM were randomly assigned to either an exercise group or a control group and were further stratified by gender. The exercise group performed 8 RT exercises in 3 sets of 8 to 12 repetitions at 75% 1-repetition maximum (1-RM) 3 times per week for 12 weeks. The control group received usual care and maintained their daily activities and lifestyle. Muscle function (1-RM and muscle oxygenation responses), physical performance (5-repetition sit-to-stand test and Timed Up and Go test), cardiometabolic risks (aerobic capacity, blood pressure, body composition, glycemic control, lipids levels, and high-sensitivity C-reactive protein levels), and QoL (Audit of Diabetes-Dependent Quality of Life 19) were assessed at baseline (week 0) and after the 12-week interventions (week 12). The 1-RM chest-press and leg-press strength and physical performance in 5-repetition sit-to-stand test were significantly improved in the exercise group compared with the controls after the interventions. The exercise group had significantly lower resting systolic blood pressure (by -12.1 mm Hg, P = 0.036) than did the controls after 12 weeks of RT, without any significant within-group change in either group after intervention. The waist circumference, fasting glucose levels, and peak diastolic blood pressure tended to favor RT over usual care after the interventions. Twelve weeks of RT increased the maximal strength in chest-press and leg-press tests, and improved 5-repetition sit-to-stand performance in older people with T2DM. Our study demonstrated that supervised, structured RT was able to promote muscle function and alleviate cardiometabolic risks in people with T2DM 65 years or older.

  2. Is stair climb power a clinically relevant measure of leg power impairments in at-risk older adults?

    PubMed

    Bean, Jonathan F; Kiely, Dan K; LaRose, Sharon; Alian, Joda; Frontera, Walter R

    2007-05-01

    To test the clinical relevance of the stair climb power test (SCPT) as a measure of leg power impairments in mobility-limited older adults. Cross-sectional analysis of baseline data from participants within a randomized controlled trial. Rehabilitation research gym. Community-dwelling older adults (N=138; mean age, 75.4 y) with mobility limitations as defined by the Short Physical Performance Battery (SPPB). Not applicable. Leg power measures included the SCPT and double leg press power measured at 40% (DLP40) and 70% (DLP70) of the 1 repetition maximum. Mobility performance tests included the SPPB and its 3 components: gait speed, chair stand time, and standing balance. Stair climb power per kilogram (SCP/kg) had correlations of moderate strength (r=.47, r=.52) with DLP40/kg and DLP70/kg, respectively. All 3 leg power measures correlated with each of the mobility performance measures with the exception of DLP40/kg (r=.11, P=.27) and DLP70/kg (r=.11, P=.18) with standing balance. Magnitudes of association, as described by the Pearson correlation coefficient, did not differ substantively among the separate power measures as they related to SPPB performance overall. Separate adjusted multivariate models evaluating the relationship between leg power and SPPB performance were all statistically significant and described equivalent amounts of the total variance (R(2)) in SPPB performance (SCP/kg, R(2)=.30; DLP40, R(2)=.32; DLP70, R(2)=.31). Analyses of the components of the SPPB show that the SCPT had stronger associations than the other leg power impairment measures with models predicting chair stand (SCP/kg, R(2)=.25; DLP40, R(2)=.12; DLP70, R(2)=.13), whereas both types of leg press power testing had stronger associations with models predicting gait speed (SCP/kg, R(2)=.16; DLP40, R(2)=.34; DLP70, R(2)=.34). Stair climb power was the only power measure that was a significant component of models predicting standing balance (SCP/kg R(2)=.20). The SCPT is a clinically relevant measure of leg power impairments. It is associated with more complex modes of testing leg power impairments and is meaningfully associated with mobility performance, making it suitable for clinical settings in which impairment-mobility relationships are of interest.

  3. Within Session Sequence of Balance and Plyometric Exercises Does Not Affect Training Adaptations with Youth Soccer Athletes.

    PubMed

    Chaouachi, Mehdi; Granacher, Urs; Makhlouf, Issam; Hammami, Raouf; Behm, David G; Chaouachi, Anis

    2017-03-01

    The integration of balance and plyometric training has been shown to provide significant improvements in sprint, jump, agility, and other performance measures in young athletes. It is not known if a specific within session balance and plyometric exercise sequence provides more effective training adaptations. The objective of the present study was to investigate the effects of using a sequence of alternating pairs of exercises versus a block (series) of all balance exercises followed by a block of plyometric exercises on components of physical fitness such as muscle strength, power, speed, agility, and balance. Twenty-six male adolescent soccer players (13.9 ± 0.3 years) participated in an 8-week training program that either alternated individual balance (e.g., exercises on unstable surfaces) and plyometric (e.g., jumps, hops, rebounds) exercises or performed a block of balance exercises prior to a block of plyometric exercises within each training session. Pre- and post-training measures included proxies of strength, power, agility, sprint, and balance such as countermovement jumps, isometric back and knee extension strength, standing long jump, 10 and 30-m sprints, agility, standing stork, and Y-balance tests. Both groups exhibited significant, generally large magnitude (effect sizes) training improvements for all measures with mean performance increases of approximately >30%. There were no significant differences between the training groups over time. The results demonstrate the effectiveness of combining balance and plyometric exercises within a training session on components of physical fitness with young adolescents. The improved performance outcomes were not significantly influenced by the within session exercise sequence.

  4. Impaired visually guided weight-shifting ability in children with cerebral palsy.

    PubMed

    Ballaz, Laurent; Robert, Maxime; Parent, Audrey; Prince, François; Lemay, Martin

    2014-09-01

    The ability to control voluntary weight shifting is crucial in many functional tasks. To our knowledge, weight shifting ability in response to a visual stimulus has never been evaluated in children with cerebral palsy (CP). The aim of the study was (1) to propose a new method to assess visually guided medio-lateral (M/L) weight shifting ability and (2) to compare weight-shifting ability in children with CP and typically developing (TD) children. Ten children with spastic diplegic CP (Gross Motor Function Classification System level I and II; age 7-12 years) and 10 TD age-matched children were tested. Participants played with the skiing game on the Wii Fit game console. Center of pressure (COP) displacements, trunk and lower-limb movements were recorded during the last virtual slalom. Maximal isometric lower limb strength and postural control during quiet standing were also assessed. Lower-limb muscle strength was reduced in children with CP compared to TD children and postural control during quiet standing was impaired in children with CP. As expected, the skiing game mainly resulted in M/L COP displacements. Children with CP showed lower M/L COP range and velocity as compared to TD children but larger trunk movements. Trunk and lower extremity movements were less in phase in children with CP compared to TD children. Commercially available active video games can be used to assess visually guided weight shifting ability. Children with spastic diplegic CP showed impaired visually guided weight shifting which can be explained by non-optimal coordination of postural movement and reduced muscular strength. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. 28. HISTORIC VIEW OF A3 ROCKET IN TEST STAND NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. HISTORIC VIEW OF A-3 ROCKET IN TEST STAND NO. 3 AT KUMMERSDORF (THE LARGEST TEST STAND AT KUMMERSDORF). THE STAND WAS MOBILE, SINCE IT MOVED ALONG RAILS. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  6. Physical Properties of Synthetic Resin Materials

    NASA Technical Reports Server (NTRS)

    Fishbein, Meyer

    1939-01-01

    A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

  7. 1. TEST STAND 1A ENVIRONS, SHOWING WEST SIDE OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEST STAND 1-A ENVIRONS, SHOWING WEST SIDE OF TEST STAND 1-A, RP1 COMBINED FUEL STORAGE TANK FARM BELOW WATER TANKS ON HILLSIDE TO LEFT, AND TEST STAND 1-B IN DISTANCE AT RIGHT. Looking east. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  8. Musculoskeletal strength, balance performance, and self-efficacy in elderly ving tsun chinese martial art practitioners: implications for fall prevention.

    PubMed

    Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Pang, Marco Y C; Lee, H W; Chung, Joanne W Y; Lam, Priscillia L; Guo, X

    2014-01-01

    Objectives. To (1) compare the bone strength, lower limb muscular strength, functional balance performance, and balance self-efficacy between Ving Tsun (VT) martial art practitioners and nonpractitioners and (2) identify the associations between lower limb muscular strength, functional balance performance, and balance self-efficacy among the VT-trained participants. Methods. Thirty-five VT practitioners (mean age ± SD = 62.7 ± 13.3 years) and 49 nonpractitioners (mean age ± SD = 65.9 ± 10.5 years) participated in the study. The bone strength of the distal radius, lower limb muscular strength, functional balance performance, and balance self-efficacy were assessed using an ultrasound bone sonometer, the five times sit-to-stand test (FTSTS), the Berg balance scale (BBS), and the Chinese version of the activities-specific balance confidence scale, respectively. A multivariate analysis of covariance was performed to compare all the outcome variables between the two groups. Results. Elderly VT practitioners had higher radial bone strength on the dominant side (P < 0.05), greater lower limb muscular strength (P = 0.001), better functional balance performance (P = 0.003), and greater balance confidence (P < 0.001) than the nonpractitioners. Additionally, only the FTSTS time revealed a significant association with the BBS score (r = -0.575,  P = 0.013). Conclusions. VT may be a suitable health-maintenance exercise for the elderly. Our findings may inspire the development of VT fall-prevention exercises for the community-dwelling healthy elderly.

  9. Musculoskeletal Strength, Balance Performance, and Self-Efficacy in Elderly Ving Tsun Chinese Martial Art Practitioners: Implications for Fall Prevention

    PubMed Central

    Fong, Shirley S. M.; Ng, Shamay S. M.; Liu, Karen P. Y.; Pang, Marco Y. C.; Lee, H. W.; Chung, Joanne W. Y.; Lam, Priscillia L.; Guo, X.

    2014-01-01

    Objectives. To (1) compare the bone strength, lower limb muscular strength, functional balance performance, and balance self-efficacy between Ving Tsun (VT) martial art practitioners and nonpractitioners and (2) identify the associations between lower limb muscular strength, functional balance performance, and balance self-efficacy among the VT-trained participants. Methods. Thirty-five VT practitioners (mean age ± SD = 62.7 ± 13.3 years) and 49 nonpractitioners (mean age ± SD = 65.9 ± 10.5 years) participated in the study. The bone strength of the distal radius, lower limb muscular strength, functional balance performance, and balance self-efficacy were assessed using an ultrasound bone sonometer, the five times sit-to-stand test (FTSTS), the Berg balance scale (BBS), and the Chinese version of the activities-specific balance confidence scale, respectively. A multivariate analysis of covariance was performed to compare all the outcome variables between the two groups. Results. Elderly VT practitioners had higher radial bone strength on the dominant side (P < 0.05), greater lower limb muscular strength (P = 0.001), better functional balance performance (P = 0.003), and greater balance confidence (P < 0.001) than the nonpractitioners. Additionally, only the FTSTS time revealed a significant association with the BBS score (r = −0.575,  P = 0.013). Conclusions. VT may be a suitable health-maintenance exercise for the elderly. Our findings may inspire the development of VT fall-prevention exercises for the community-dwelling healthy elderly. PMID:25530782

  10. Motor abilities and anthropometrics in youth cross-country skiing.

    PubMed

    Stöggl, R; Müller, E; Stöggl, T

    2015-02-01

    The purposes were to validate whether general motor abilities and anthropometrics are determinants of youth cross-country (XC) skiing performance; evaluate gender-specific differences; and to establish noninvasive diagnostics. Fifty-one youth XC skiers (34 boys; 13.8 ± 0.6 years and 17 girls; 13.4 ± 0.9 years) performed motor skill and laboratory tests, and anthropometric data were collected and correlated with XC skiing performance. Anthropometrics and maturity status were related to boys but not to girls XC skiing performance. Push-ups and 20-m sprint were correlated to XC skiing performance in both boys and girls. XC skiing performance of boys was predominantly influenced by upper body and trunk strength capacities (medicine ball throw, push-ups, and pull-ups) and jumping power (standing long and triple jump), whereas XC skiing of girls was mainly influenced by aerobic capacities (3000-m run). Laboratory measures did not reveal greater correlations to XC skiing performance compared with simple test concepts of speed, strength, and endurance. Maturity was a major confounding variable in boys but not girls. Use of noninvasive simple test concepts for determination of upper body strength, speed, and endurance represent practicable support for ski clubs, schools, or skiing federations in the guidance and evaluation of young talent, being aware of the effect of maturity especially in boys. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Corrosion Behavior of Steel Reinforcement in Concrete with Recycled Aggregates, Fly Ash and Spent Cracking Catalyst

    PubMed Central

    Gurdián, Hebé; García-Alcocel, Eva; Baeza-Brotons, Francisco; Garcés, Pedro; Zornoza, Emilio

    2014-01-01

    The main strategy to reduce the environmental impact of the concrete industry is to reuse the waste materials. This research has considered the combination of cement replacement by industrial by-products, and natural coarse aggregate substitution by recycled aggregate. The aim is to evaluate the behavior of concretes with a reduced impact on the environment by replacing a 50% of cement by industrial by-products (15% of spent fluid catalytic cracking catalyst and 35% of fly ash) and a 100% of natural coarse aggregate by recycled aggregate. The concretes prepared according to these considerations have been tested in terms of mechanical strengths and the protection offered against steel reinforcement corrosion under carbonation attack and chloride-contaminated environments. The proposed concrete combinations reduced the mechanical performance of concretes in terms of elastic modulus, compressive strength, and flexural strength. In addition, an increase in open porosity due to the presence of recycled aggregate was observed, which is coherent with the changes observed in mechanical tests. Regarding corrosion tests, no significant differences were observed in the case of the resistance of these types of concretes under a natural chloride attack. In the case of carbonation attack, although all concretes did not stand the highly aggressive conditions, those concretes with cement replacement behaved worse than Portland cement concretes. PMID:28788613

  12. An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

    PubMed

    Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang

    2012-02-01

    Previously, the choice of prosthetic implant-retained overdentures has depended on data from previous studies about the retention-fatigue strength of the attachment system selected. Little or no data have been available on the correlation between the attachment system selected and the overdenture support configuration. The purpose of the present study was to evaluate the retention force and fatigue resistance of three attachment systems and four support designs of overdenture prosthesis. Four lower edentulous acrylic models were prepared and eight combinations of attachments groups were investigated in the study. These included: O-Rings with mini-dental implants (MDIs), Dalbo elliptic with Dalbo Rotex and fabricated flexible acrylic attachments with both MDI and Dalbo Rotex. The study was divided into four test groups: groups A and B, controls, and groups C and D, experimental groups. Control group A contained three overdenture supports: two free standing MDIs in the canine region and at the midline, and one simulated tooth root with Dalbo Rotex screwed in. Control group B contained four overdenture support foundations: two free standing MDIs in the right canine region and the first premolar region, and two simulated tooth roots with Dalbo Rotex screwed in at the same MDI position, but on the left side of the model. Experimental group C contained three overdenture support foundations: two free standing MDIs in the canine region and at the midline, and one simulated tooth root with MDI screwed in. Experimental group D contained four overdenture support foundations: two free standing MDIs in the right canine region and the first premolar region, and two simulated tooth roots with MDIs screwed in at the same MDI position, but on the left side of the model. Each group was further divided into two subgroups according to attachment type used. Five samples were prepared for each group. Retention force (N) values were recorded initially (0 cycles) and after 360, 720, 1440 and 2880 insertion and removal cycles. During the tensile test a cross-head speed of 10 mm/min was applied. Values of absolute force (AF) and relative force (RF) were statistically analyzed by two-way ANOVA and multiple comparison Tukey's tests between groups and cycles periods. The results of fatigue tests showed a 50% reduction in retention force in the subgroups with flexible attachments. A triangular design of overdenture support foundations with O-Ring attachments revealed the lowest value of AF and a relatively high reduction in RF. The four overdenture support designs with flexible acrylic attachments improved the retention force and reduced the fatigue retention. Furthermore, the results of the investigation demonstrate that flexible acrylic attachments for both teeth and implant-supported overdentures offer a wide range of retention forces.

  13. The physiological, musculoskeletal and psychological effects of stand up paddle boarding.

    PubMed

    Schram, Ben; Hing, Wayne; Climstein, Mike

    2016-01-01

    Stand up paddle boarding (SUP) is a rapidly growing sport and recreational activity where anecdotal evidence exists for its proposed health, fitness and injury rehabilitation benefits. While limited scientific evidence exists to substantiate these claims, previous studies have shown that high levels of fitness, strength and balance exists amongst participants of this sport. The purpose of this study was to conduct a training intervention on a group of previously untrained individuals to ascertain the potential of SUP on various health parameters. An intervention study was conducted where after being tested initially, subjects were left for 6 weeks to act as their own control before the SUP intervention began. A total of 13 SUP participants completed the training study (nine males, four females) which was comprised of three 1 h sessions per week for 6 weeks. No significant changes occurred during the initial control period. Significant ( P  < 0.05) improvements were made in aerobic (+23.57 %) and anaerobic fitness (+41.98 %), multidirectional core strength tests (prone +19.78 %, right side +26.19 %, left side +28.31 %, Biering Sorensen +21.33 %) and self-rated quality of life questionnaires in the physical (+19.99 %) and psychological (+17.49 %) domains. No significant changes were detected in static or dynamic balance over the duration of the training intervention. These results demonstrate the cardiovascular, musculoskeletal and psychological improvements achievable for the novice when utilizing SUP as a training tool. The result from this study provides some evidence to substantiate the claims of health and fitness benefits SUP.

  14. A new injury prevention programme for children's football--FIFA 11+ Kids--can improve motor performance: a cluster-randomised controlled trial.

    PubMed

    Rössler, R; Donath, L; Bizzini, M; Faude, O

    2016-01-01

    The present study evaluated the effects of a newly developed injury prevention programme for children's football ("FIFA 11+ Kids") on motor performance in 7-12-year-old children. We stratified 12 football teams (under-9/-11/-13 age categories) into intervention (INT, N = 56 players) and control groups (CON, N = 67). INT conducted the 15-min warm-up programme "FIFA 11+ Kids" twice a week for 10 weeks. CON followed a standard warm-up (sham treatment). Pre- and post-tests were conducted using: single leg stance; Y-balance test; drop and countermovement jump; standing long jump; 20-m sprint; agility run; slalom dribble; and wall volley test. We used magnitude-based inferences and linear mixed-effects models to analyse performance test results. We observed likely beneficial effects favouring INT in Y-balance (right leg; +3.2%; standardised mean difference (SMD) = 0.34; P = 0.58) and agility run (+3.6%; SMD = 0.45; P = 0.008). Possibly beneficial effects were found in Y-balance, drop jump reactive strength index, drop jump height, countermovement jump, standing long jump, slalom dribble and wall volley test. At least possibly beneficial improvements in favour of "FIFA 11+ Kids" were observed in nearly all parameters. Most effects were small, but slight improvements in motor performance may potentially contribute to a reduction of injury risk.

  15. 20. Building 202, detail of stand A, rocket test stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Building 202, detail of stand A, rocket test stand in test cell. View looking southeast. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  16. 31. HISTORIC VIEW OF TEST STAND NO. 1 AT PEENEMUENDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. HISTORIC VIEW OF TEST STAND NO. 1 AT PEENEMUENDE A-4 ENGINE AND ROCKET PROPULSION TEST STAND. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  17. Predicting performance and injury resilience from movement quality and fitness scores in a basketball team over 2 years.

    PubMed

    McGill, Stuart M; Andersen, Jordan T; Horne, Arthur D

    2012-07-01

    The purpose of this study was to see if specific tests of fitness and movement quality could predict injury resilience and performance in a team of basketball players over 2 years (2 playing seasons). It was hypothesized that, in a basketball population, movement and fitness scores would predict performance scores and that movement and fitness scores would predict injury resilience. A basketball team from a major American university (N = 14) served as the test population in this longitudinal trial. Variables linked to fitness, movement ability, speed, strength, and agility were measured together with some National Basketball Association (NBA) combine tests. Dependent variables of performance indicators (such as games and minutes played, points scored, assists, rebounds, steal, and blocks) and injury reports were tracked for the subsequent 2 years. Results showed that better performance was linked with having a stiffer torso, more mobile hips, weaker left grip strength, and a longer standing long jump, to name a few. Of the 3 NBA combine tests administered here, only a faster lane agility time had significant links with performance. Some movement qualities and torso endurance were not linked. No patterns with injury emerged. These observations have implications for preseason testing and subsequent training programs in an attempt to reduce future injury and enhance playing performance.

  18. GENERAL VIEW OF SITE LOOKING SOUTHWEST. JUPITER 'HOP' STAND, FOREGROUND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW OF SITE LOOKING SOUTHWEST. JUPITER 'HOP' STAND, FOREGROUND CENTER, REDSTONE TEST STAND FOREGROUND RIGHT, SATURN I C TEST STAND BACKGROUND LEFT. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  19. The effects of strength training on cognitive performance in elderly women.

    PubMed

    Smolarek, André de Camargo; Ferreira, Luis Henrique Boiko; Mascarenhas, Luis Paulo Gomes; McAnulty, Steven R; Varela, Karla Daniele; Dangui, Mônica C; de Barros, Marcelo Paes; Utter, Alan C; Souza-Junior, Tácito P

    2016-01-01

    Aging is a degenerative process marked by recognized functional, physiological, and metabolic impairments, such as dynapenia and diminished cognitive capacity. Therefore, the search for innovative strategies to prevent/delay these physiological and cognitive disorders is essential to guarantee the independence and life quality of an elderly population. The aim of this work is to verify the effect of a 12-week resistance exercise program on the general physical aptitude and cognitive capacities of elderly and sedentary women. Twenty-nine women (65.87±5.69 years) were divided into two groups. The control group was composed of eight elderly women who met the same inclusion criteria of the study and the strength training group was composed of 29 elderly women who were subjected to a resistance exercise program defined by 12 upper and lower limb exercises combined in 3×10 repetitions with 1-minute interval between repetitions and two resting minutes between exercises (three times/week). Weight loads were fixed between 60% and 75% of the apparent 1 repetition maximum, which was estimated by the test of 10 maximum repetitions. The direct curl was performed for upper body strength evaluation with 2.3 kg dumbbells for 30 seconds, whereas the chair test was used for lower body evaluation (total sit-stand movements in 30 seconds). The cognitive capacities of subjects were evaluated by "The Montreal Cognitive Assessment" questionnaire. After 12 weeks, the elderly group showed significant increases in the average upper body strength (58%), lower body strength (68%), and cognitive capacity (19%). The present study demonstrated that regular resistance exercises could provide significant gains on the upper and lower body strength concomitant to positive improvements on cognitive capacities of elderly women, bringing enhanced life quality.

  20. Decline in measured glomerular filtration rate is associated with a decrease in endurance, strength, balance and fine motor skills.

    PubMed

    Hellberg, Matthias; Höglund, Peter; Svensson, Philippa; Abdulahi, Huda; Clyne, Naomi

    2017-07-01

    Physical performance in chronic kidney disease affects morbidity and mortality. The aim was to find out which measures of physical performance are important in chronic kidney disease (CKD) and if there are associations with declining measured glomerular filtration rate (GFR). Endurance was assessed by 6 min walk test (6-MWT) and stair climbing, muscular endurance by 30 s sit to stand, heel rises and toe lifts, strength by quadriceps- and handgrip-strength, balance by functional reach and Berg's balance scale, and fine motor skills by Moberg's picking-up test. GFR was measured by Iohexol clearance. The study comprised 101 patients with CKD 3b-5 not started dialysis, 40 women and 61 men, with a mean age of 67 ± 13 (range: 22 - 87) years. All measures of physical performance were impaired. A decrease in GFR of 10 mL/min per 1.73 m 2 corresponded to a 35 metre shorter walking distance in the 6-MWT. Multivariable linear regression analysis showed significant relationships between decline in GFR and the 6-MWT (P = 0.04), isometric quadriceps strength left (P = 0.04), balance measured as functional reach (P = 0.02) and fine motor skills in the left hand as measured by Moberg's picking-up test (P = 0.01), respectively, after sex, age, comorbidity and the interaction between sex and age had been taken into account. Endurance, muscular endurance, strength, balance and fine motor skills were impaired in patients with CKD 3b-5. Walking capacity, isometric quadriceps strength, balance, and fine motor skills were associated with declining GFR. The left extremities were more susceptible to GFR, ageing and comorbidities and seem thus to be more sensitive. © 2016 Asian Pacific Society of Nephrology.

  1. Where and When do Species Interactions Set Range Limits?

    PubMed

    Louthan, Allison M; Doak, Daniel F; Angert, Amy L

    2015-12-01

    A long-standing theory, originating with Darwin, suggests that abiotic forces set species range limits at high latitude, high elevation, and other abiotically 'stressful' areas, while species interactions set range limits in apparently more benign regions. This theory is of considerable importance for both basic and applied ecology, and while it is often assumed to be a ubiquitous pattern, it has not been clearly defined or broadly tested. We review tests of this idea and dissect how the strength of species interactions must vary across stress gradients to generate the predicted pattern. We conclude by suggesting approaches to better test this theory, which will deepen our understanding of the forces that determine species ranges and govern responses to climate change. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Physical fitness reference standards in European children: the IDEFICS study.

    PubMed

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  3. Therapeutic riding followed by rhythmic auditory stimulation to improve balance and gait in a subject with orthopedic pathologies.

    PubMed

    Ungermann, Cathryn M; Gras, Laura Z

    2011-12-01

    The study objectives were to investigate the effect of therapeutic riding with a subject who had an orthopedic diagnosis. This is a single-subject case report. The study was conducted at an equestrian facility with an indoor riding arena. The subject was a 59-year-old woman with grade I spondylolisthesis at L4/L5 and multilevel lumbar spinal stenosis in central and foraminal canals. The subject had an anterior cervical fusion of C3-C7. The subject has been ambulating with a straight cane due to her history of frequent falls. Gait, agility, strength, range of motion, and balance testing were performed. The subject had impairments of bilateral lower extremities with an ataxic gait pattern and was at risk for continued falls according to the balance measures. The intervention comprised therapeutic riding sessions 3 times a week for 20 minutes for 4 weeks. Each riding session was immediately followed by a 10-minute independent walking program with a metronome for rhythmic auditory stimulation. The outcome measures were as follows: Manual muscle testing and range of motion of the lower extremities, Gait Speed Test, Dynamic Gait Index, Four-Square Step Test, Chair Stand Test, Single Leg Stance. Improvements were seen in lower extremity strength and range of motion and balance. The subject improved on balance scores, placing her out of the risk for falls category. Therapeutic riding followed by rhythmic auditory stimulation improved lower extremity range of motion, strength, and balance with this subject.

  4. Haemophilia & Exercise Project (HEP): the impact of 1-year sports therapy programme on physical performance in adult haemophilia patients.

    PubMed

    Czepa, D; von Mackensen, S; Hilberg, T

    2013-03-01

    Episodes of bleeding in people with haemophilia (PWH) are associated with reduced activity and limitations in physical performance. Within the scope of the 'Haemophilia & Exercise Project' (HEP) PWH were trained in a sports therapy programme. Aim of this study was to investigate subjective and objective physical performance in HEP-participants after 1 year training. Physical performance of 48 adult PWH was compared before and after sports therapy subjectively (HEP-Test-Q) and objectively regarding mobility (range of motion), strength and coordination (one-leg-stand) and endurance (12-min walk test). Sports therapy included an independent home training that had previously been trained in several collective sports camps. Forty-three controls without haemophilia and without training were compared to PWH. Of 48 PWH, 13 performed a regular training (active PWH); 12 HEP-participants were constantly passive (passive PWH). Twenty-three PWH and 24 controls dropped out because of incomplete data. The activity level increased by 100% in active PWH and remained constant in passive PWH, and in controls (P ≤ 0.05). Only mobility of the right knee was significantly improved in active PWH (+5.8 ± 5.3°) compared to passive PWH (-1.3 ± 8.6°). The 12-min walk test proved a longer walking distance for active PWH (+217 ± 199 m) compared to controls (-32 ± 217 m). Active PWH reported a better subjective physical performance in the HEP-Test-Q domains 'strength & coordination', 'endurance' and in the total score (+9.4 ± 13.8) compared to passive PWH (-5.3 ± 13.5) and controls (+3.7 ± 7.5). The 'mobility'-scale and one-leg-stand remained unchanged. Sports therapy increases the activity level and physical performance of PWH, whereby objective effects do not always correspond with subjective assessments. © 2012 Blackwell Publishing Ltd.

  5. Effects of functional training on pain, leg strength, and balance in women with fibromyalgia.

    PubMed

    Latorre Román, Pedro Ángel; Santos E Campos, María Aparecida; García-Pinillos, Felipe

    2015-01-01

    The aim of this study was to analyze the effect of 18-week functional training (FT) program consisting in two sessions a week of in-water exercise and one of on-land exercise on pain, strength, and balance in women with fibromyalgia. A sample consisting of 36 fibromyalgia patients was included in the study. The patients were allocated randomly into the experimental group (EG, n = 20), and control group (CG, n = 16). Standardized field-based fitness tests were used to assess muscle strength (30-s chair stand and handgrip strength) and agility/dynamic balance and static balance. Fibromyalgia impact and pain were analyzed by Fibromyalgia Impact Questionnaire (FIQ), tender points (TPs), visual analog scale (VAS). We observed a significant reduction in the FIQ (p = 0.042), the algometer scale of TP (p = 0.008), TP (p < 0.001), and VAS (p < 0.001) in the EG. The EG shows better results in leg strength (p < 0.001), handgrip strength (p = 0.025), agility/dynamic balance (p = 0.032) and balance (p = 0.006). An 18-week intervention consisting in two sessions of in-water exercise and one session of on-land exercise of FT reduces pain and improves functional capacity in FM patients. These results suggested that FT could play an important role in maintaining an independent lifestyle in patients with FM.

  6. Wasting syndrome with deep bradycardia as presenting manifestation of long-standing severe male hypogonadotropic hypogonadism: a case series.

    PubMed

    Passeri, Elena; Bonomi, Marco; Dangelo, Francesco; Persani, Luca; Corbetta, Sabrina

    2014-09-27

    Physiological functioning of the testes is important for cardiac health besides for virilisation, physical strength, behavior and reproduction; moreover, hypogonadism has been demonstrated as a significant risk marker of increased all-cause and cardiovascular mortality. We reported two cases of long-standing hypogonadotropic hypogonadism presenting with wasting, bradycardia and heart failure. The two patients were admitted to emergency department for deep weakness, unresponsive anemia and severe bradycardia, requiring in one case the implanting of a monocameral pace-maker for treatment of heart failure. No previous cardiologic disorders were known and cardiac ischemia was ruled out in both patients. The first patient presented congenital hypogonadotropic hypogonadism combined with mild central hypothyroidism and growth hormone deficiency occurred in the peripubertal age, while the second one was diagnosed with isolated adult-onset severe central hypogonadism. Testosterone deficiency was the main feature in both patients as physical examination revealed clinical stigmata of hypogonadism and testosterone replacement induced a dramatic improvement of general condition. Genetic analysis of genes involved in hypogonadotropic hypogonadism failed to identify alterations. Long-standing hypogonadism in males can be associated with life threatening body alterations including severe bradycardia and heart failure.

  7. Longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury.

    PubMed

    Triolo, Ronald J; Bailey, Stephanie Nogan; Miller, Michael E; Rohde, Loretta M; Anderson, James S; Davis, John A; Abbas, James J; DiPonio, Lisa A; Forrest, George P; Gater, David R; Yang, Lynda J

    2012-05-01

    To investigate the longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury. Case series. Research or outpatient physical therapy departments of 4 academic hospitals. Subjects (N=15) with thoracic or low cervical level spinal cord injuries who had received the 8-channel neuroprosthesis for exercise and standing. After completing rehabilitation with the device, the subjects were discharged to unrestricted home use of the system. A series of assessments were performed before discharge and at a follow-up appointment approximately 1 year later. Neuroprosthesis usage, maximum standing time, body weight support, knee strength, knee fatigue index, electrode stability, and component survivability. Levels of maximum standing time, body weight support, knee strength, and knee fatigue index were not statistically different from discharge to follow-up (P>.05). Additionally, neuroprosthesis usage was consistent with subjects choosing to use the system on approximately half of the days during each monitoring period. Although the number of hours using the neuroprosthesis remained constant, subjects shifted their usage to more functional standing versus more maintenance exercise, suggesting that the subjects incorporated the neuroprosthesis into their lives. Safety and reliability of the system were demonstrated by electrode stability and a high component survivability rate (>90%). This group of 15 subjects is the largest cohort of implanted lower-extremity neuroprosthetic exercise and standing system users. The safety and efficiency data from this group, and acceptance of the neuroprosthesis as demonstrated by continued usage, indicate that future efforts toward commercialization of a similar device may be warranted. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Standing Vs Supine; Does it Matter in Cough Stress Testing?

    PubMed

    Patnam, Radhika; Edenfield, Autumn L; Swift, Steven E

    The aim of this study was to compare the sensitivity of cough stress test in the standing versus supine position in the evaluation of incontinent females. We performed a prospective observational study of women with the chief complaint of urinary incontinence (UI) undergoing a provocative cough stress test (CST). Subjects underwent both a standing and a supine CST. Testing order was randomized via block randomization. Cough stress test was performed in a standard method via backfill of 200 mL or until the subject described strong urge. The subjects were asked to cough, and the physician documented urine leakage by direct observation. The gold standard for stress UI diagnosis was a positive CST in either position. Sixty subjects were enrolled, 38 (63%) tested positive on any CST, with 38 (63%) positive on standing compared with 29 (28%) positive on supine testing. Nine women (15%) had positive standing and negative supine testing. No subjects had negative standing with positive supine testing. There were no significant differences in positive tests between the 2 randomized groups (standing first and supine second vs. supine first and standing second). When compared with the gold standard of any positive provocative stress test, the supine CST has a sensitivity of 76%, whereas the standing CST has a sensitivity of 100%. The standing CST is more sensitive than the supine CST and should be performed in any patient with a complaint of UI and negative supine CST. The order of testing either supine or standing first does not affect the results.

  9. Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear.

    PubMed

    Kim, Young-Mo; Joo, Yong-Bum

    2013-07-01

    To evaluate the reparability of the posterior horn of the medial meniscus with root ligament tear by measuring the actual pullout failure strength of a simple vertical suture of an arthroscopic subtotal meniscectomized posterior horn of the medial meniscus. From November 2009 to May 2010, nine posterior horns of the medial meniscus specimens were collected from arthroscopic subtotal meniscectomy performed as a treatment for root ligament rupture of the posterior horn of the medial meniscus. Simple vertical sutures were performed on the specimens, and pullout failure load was tested with a biaxial servohydraulic testing machine (Model 8874; Instron Corp., Norwood, MA, USA). The degree of degeneration, extrusion, and medial displacement of the medial meniscus were evaluated with magnetic resonance imaging (MRI). The Kellgren-Lawrence classification was used in standing plain radiography, and mechanical alignment was measured using orthoroentgenography. Tear morphology was classified into ligament proper type or meniscoligamentous junctional type according to the site of the torn root ligament of the posterior horn of the medial meniscus during arthroscopy. The mean pullout failure strength of the posterior horn of the medial meniscus was 71.6 ± 23.2 N (range, 41.4-107.7 N). The degree of degeneration of the posterior horn of the medial meniscus on MRI showed statistically significant correlation with pullout failure strength and Kellgren-Lawrence classification. Pullout failure strength showed correlation with mechanical alignment and Kellgren-Lawrence classification (P < 0.05). The measurement of pullout failure strength of the posterior horn of the medial meniscus with root ligament tear showed a degree of repairability. The degree of degeneration of the posterior horn of the medial meniscus on MRI showed a significant correlation with the pullout failure strength. The pullout failure strength was also not only correlated with the degree of degeneration of the posterior horn of the medial meniscus, but also with mechanical alignment and Kellgren-Lawrence classification, which represent bony degenerative change.

  10. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Work continues on the A-3 Test Stand at Stennis Space Center. The new stand will allow operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet. The test stand is scheduled for completion and activation in 2013.

  11. A-3 Test Stand construction

    NASA Image and Video Library

    2010-10-01

    An 80,000-gallon liquid hydrogen tank is placed at the A-3 Test Stand construction site on Sept. 24, 2010. The tank will provide propellant for tests of next-generation rocket engines at the stand. It will be placed upright on top of the stand, helping to increase the overall height to 300 feet. Once completed, the A-3 Test Stand will enable operators to test rocket engines at simulated altitudes of up to 100,000 feet. The A-3 stand is the first large rocket engine test structure to be built at Stennis Space Center since the 1960s.

  12. A-3 Test Stand construction

    NASA Image and Video Library

    2010-09-24

    A 35,000-gallon liquid oxygen tank is placed at the A-3 Test Stand construction site on Sept. 24, 2010. The tank will provide propellant for tests of next-generation rocket engines at the stand. It will be placed upright on top of the stand, helping to increase the overall height to 300 feet. Once completed, the A-3 Test Stand will enable operators to test rocket engines at simulated altitudes of up to 100,000 feet. The A-3 stand is the first large rocket engine test structure to be built at Stennis Space Center since the 1960s.

  13. Photographic copy of site plan for proposed Test Stand "D" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of site plan for proposed Test Stand "D" in 1958. The contemporary site plans of test stands "A," "B," and "C" are also visible, along with the interconnecting tunnel system. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering "Site Plan for Proposed Test Stand "D" - Edwards Test Station," drawing no. ESP/22-0, 14 November 1958 - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  14. A-3 Test Stand continues with test cell installation

    NASA Image and Video Library

    2010-07-20

    Employees at Stennis Space Center continue work on the A-3 Test Stand. As shown, a section of the test cell is lifted for installation on the stand's structural steel frame. Work on the A-3 Test Stand began in 2007. It is scheduled for activation in 2012.

  15. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladder June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  16. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladded June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  17. Effect of Yoga Based Lifestyle Intervention on Patients With Knee Osteoarthritis: A Randomized Controlled Trial

    PubMed Central

    Deepeshwar, Singh; Tanwar, Monika; Kavuri, Vijaya; Budhi, Rana B.

    2018-01-01

    Objective: To investigate the effect of integrated approach of yoga therapy (IAYT) intervention in individual with knee Osteoarthritis. Design: Randomized controlled clincial trail. Participants: Sixty-six individual prediagnosed with knee osteoarthritis aged between 30 and 75 years were randomized into two groups, i.e., Yoga (n = 31) and Control (n = 35). Yoga group received IAYT intervention for 1 week at yoga center of S-VYASA whereas Control group maintained their normal lifestyle. Outcome measures: The Falls Efficacy Scale (FES), Handgrip Strength test (left hand LHGS and right hand RHGS), Timed Up and Go Test (TUG), Sit-to-Stand (STS), and right & left extension and flexion were measured on day 1 and day 7. Results: There were a significant reduction in TUG (p < 0.001), Right (p < 0.001), and Left Flexion (p < 0.001) whereas significant improvements in LHGS (p < 0.01), and right extension (p < 0.05) & left extension (p < 0.001) from baseline in Yoga group. Conclusion: IAYT practice showed an improvement in TUG, STS, HGS, and Goniometer test, which suggest improved muscular strength, flexibility, and functional mobility. CTRI Registration Number: http://ctri.nic.in/Clinicaltrials, identifier CTRI/2017/10/010141. PMID:29867604

  18. Stress Prediction System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    NASA wanted to know how astronauts' bodies would react under various gravitational pulls and space suit weights. Under contract to NASA, the University of Michigan's Center for Ergonomics developed a model capable of predicting what type of stress and what degree of load a body could stand. The algorithm generated was commercialized with the ISTU (Isometric Strength Testing Unit) Functional Capacity Evaluation System, which simulates tasks such as lifting a heavy box or pushing a cart and evaluates the exertion expended. It also identifies the muscle group that limits the subject's performance. It is an effective tool of personnel evaluation, selection and job redesign.

  19. 13. Photographic copy of site plan displaying Test Stand 'C' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Photographic copy of site plan displaying Test Stand 'C' (4217/E-18), Test Stand 'D' (4223/E-24), and Control and Recording Center (4221/E-22) with ancillary structures, and connecting roads and services. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office 'Repairs to Test Stand 'C,' Edwards Test Station, Legend & Site Plan M-1,' drawing no. ESP/115, August 14, 1987. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  20. Credit WCT. Photographic copy of photograph, view of Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view of Test Stand "D" from Test Stand "A" while a rocket engine test is in progress. Cloud of steam is from partly from water created by propellant reaction and from water sprayed by flame bucket into engine exhaust for cooling purposes. A portion of Test Stand "C" is visible at the far right. (JPL negative no. 384-2082-B, 23 October 1959) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  1. Can Quantitative Muscle Strength and Functional Motor Ability Differentiate the Influence of Age and Corticosteroids in Ambulatory Boys with Duchenne Muscular Dystrophy?

    PubMed

    Buckon, Cathleen; Sienko, Susan; Bagley, Anita; Sison-Williamson, Mitell; Fowler, Eileen; Staudt, Loretta; Heberer, Kent; McDonald, Craig M; Sussman, Michael

    2016-07-08

    In the absence of a curative treatment for Duchenne Muscular Dystrophy (DMD), corticosteroid therapy (prednisone, deflazacort) has been adopted as the standard of care, as it slows the progression of muscle weakness and enables longer retention of functional mobility. The ongoing development of novel pharmacological agents that target the genetic defect underlying DMD offer hope for a significant alteration in disease progression; however, substantiation of therapeutic efficacy has proved challenging. Identifying functional outcomes sensitive to the early, subtle changes in muscle function has confounded clinical trials. Additionally, the alterations in disease progression secondary to corticosteroid therapy are not well described making it difficult to ascertain the benefits of novel agents, often taken concurrently with corticosteroids. The purpose of this study was to examine outcome responsiveness to corticosteroid therapy and age at the onset of a natural history study of ambulatory boys with DMD. Eighty-five ambulatory boys with DMD (mean age 93 mo, range 49 to 180 mo) were recruited into this study. Fifty participants were on corticosteroid therapy, while 33 were corticosteroid naïve at the baseline assessment. Within each treatment group boys were divided in two age groups, 4 to 7 years and 8 and greater years of age. The Biodex System 3 Pro isokinetic dynamometer was used to assess muscle strength. Motor skills were assessed using the upper two dimensions (standing/walking, running & jumping) of the Gross Motor Function Measure (GMFM 88) and Timed Motor Tests (TMTs) (10-meter run, sit to stand, supine to stand, climb 4-stairs). Two way analysis of variance and Pearson correlations were used for analysis. A main effect for age was seen in select lower extremity muscle groups (hip flexors, knee extensors and ankle dorsiflexors), standing dimension skills, and all TMTs with significantly greater weakness and loss of motor skill ability seen in the older age group regardless of treatment group. Interaction effects were seen for the walking, running, and jumping dimension of the GMFM with the naïve boys scoring higher in the younger group and boys on corticosteroid therapy scoring higher in the older group. The TMT of climb 4-stairs demonstrated a significant treatment effect with the boys on corticosteroid therapy climbing stairs faster than those who were naïve, regardless of age. Examination of individual items within the upper level GMFM dimensions revealed select motor skills are more informative of disease progression than others; indicating their potential to be sensitive indicators of alterations in disease progression and intervention efficacy. Analysis of the relationship between muscle group strength and motor skill performance revealed differences in use patterns in the corticosteroid versus naïve boys. Significant muscle weakness is apparent in young boys with DMD regardless of corticosteroid treatment; however, older boys on corticosteroid therapy tend to have greater retention of muscle strength and motor skill ability than those who are naive. Quantification of muscle strength via isokinetic dynamometry is feasible and sensitive to the variable rates of disease progression in lower extremity muscle groups, but possibly most informative are the subtle changes in the performance characteristics of select motor skills. Further analysis of longitudinal data from this study will explore the influence of corticosteroid therapy on muscle strength and further clarify its impact on motor performance.

  2. Effects of a resistance training program performed with an interocclusal splint for community-dwelling older adults: a randomized controlled trial

    PubMed Central

    Hirase, Tatsuya; Inokuchi, Shigeru; Matsusaka, Nobuou; Nakahara, Kazumi; Okita, Minoru

    2016-01-01

    [Purpose] To examine whether resistance training for elderly community-dwellers performed with an interocclusal splint resulted in greater lower extremity muscle strength and better balance than resistance training performed without an interocclusal splint. [Subjects and Methods] Eighty-eight elderly persons using Japanese community day centers were randomly divided into two groups: an intervention group (n=45), which performed resistance training with an interocclusal splint; and a control group (n=43), which performed resistance training without an interocclusal splint. The resistance training program comprised a 40-min session performed twice a week for 12 weeks. Outcome measures were the chair stand test (CST), timed up and go test (TUG), and one-leg standing test (OLST). Assessments were conducted before the intervention and every 2 weeks after the start of the intervention. [Results] There was a significant group × time interaction for the OLST, with the intervention group showing significant improvement from 8 to 12 weeks compared to the control group. For the CST and TUG, no significant differences were found between the two groups throughout the 12 weeks. [Conclusion] Resistance training with an interocclusal splint improved the balance ability of elderly community-dwellers more effectively than resistance training without an interocclusal splint. PMID:27313359

  3. Effects of a resistance training program performed with an interocclusal splint for community-dwelling older adults: a randomized controlled trial.

    PubMed

    Hirase, Tatsuya; Inokuchi, Shigeru; Matsusaka, Nobuou; Nakahara, Kazumi; Okita, Minoru

    2016-05-01

    [Purpose] To examine whether resistance training for elderly community-dwellers performed with an interocclusal splint resulted in greater lower extremity muscle strength and better balance than resistance training performed without an interocclusal splint. [Subjects and Methods] Eighty-eight elderly persons using Japanese community day centers were randomly divided into two groups: an intervention group (n=45), which performed resistance training with an interocclusal splint; and a control group (n=43), which performed resistance training without an interocclusal splint. The resistance training program comprised a 40-min session performed twice a week for 12 weeks. Outcome measures were the chair stand test (CST), timed up and go test (TUG), and one-leg standing test (OLST). Assessments were conducted before the intervention and every 2 weeks after the start of the intervention. [Results] There was a significant group × time interaction for the OLST, with the intervention group showing significant improvement from 8 to 12 weeks compared to the control group. For the CST and TUG, no significant differences were found between the two groups throughout the 12 weeks. [Conclusion] Resistance training with an interocclusal splint improved the balance ability of elderly community-dwellers more effectively than resistance training without an interocclusal splint.

  4. Credit BG. View looking northeast at southwestern side of Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking northeast at southwestern side of Test Stand "D" complex. Test Stand "D" workshop (Building 4222/E-23) is at left; shed to its immediate right is an entrance to underground tunnel system which interconnects all test stands. To the right of Test Stand "D" tower are four Clayton water-tube flash boilers once used in the Steam Generator Plant 4280/E-81 to power the vacuum ejector system at "D" and "C" stands. A corner of 4280/E-81 appears behind the boilers. Boilers were removed as part of stand dismantling program. The Dv (vertical vacuum) Test Cell is located in the Test Stand "D" tower, behind the sunscreen on the west side. The top of the tower contains a hoist for lifting or lowering rocket engines into the Dv Cell. Other equipment mounted in the tower is part of the steam-driven vacuum ejector system - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  5. 1. Photographic copy of original engineering drawing for Test Stand ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of original engineering drawing for Test Stand 'C.' California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'New Test Stand Plan -- Edwards Test Station' drawing no. E18/2-3, 18 January 1957. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  6. Within Session Sequence of Balance and Plyometric Exercises Does Not Affect Training Adaptations with Youth Soccer Athletes

    PubMed Central

    Chaouachi, Mehdi; Granacher, Urs; Makhlouf, Issam; Hammami, Raouf; Behm, David G; Chaouachi, Anis

    2017-01-01

    The integration of balance and plyometric training has been shown to provide significant improvements in sprint, jump, agility, and other performance measures in young athletes. It is not known if a specific within session balance and plyometric exercise sequence provides more effective training adaptations. The objective of the present study was to investigate the effects of using a sequence of alternating pairs of exercises versus a block (series) of all balance exercises followed by a block of plyometric exercises on components of physical fitness such as muscle strength, power, speed, agility, and balance. Twenty-six male adolescent soccer players (13.9 ± 0.3 years) participated in an 8-week training program that either alternated individual balance (e.g., exercises on unstable surfaces) and plyometric (e.g., jumps, hops, rebounds) exercises or performed a block of balance exercises prior to a block of plyometric exercises within each training session. Pre- and post-training measures included proxies of strength, power, agility, sprint, and balance such as countermovement jumps, isometric back and knee extension strength, standing long jump, 10 and 30-m sprints, agility, standing stork, and Y-balance tests. Both groups exhibited significant, generally large magnitude (effect sizes) training improvements for all measures with mean performance increases of approximately >30%. There were no significant differences between the training groups over time. The results demonstrate the effectiveness of combining balance and plyometric exercises within a training session on components of physical fitness with young adolescents. The improved performance outcomes were not significantly influenced by the within session exercise sequence. Key points The combination of balance and plyometric exercises can induce significant and substantial training improvements in muscle strength, power, speed, agility, and balance with adolescent youth athletes The within training session sequence of balance and plyometric exercises does not substantially affect these training improvements. PMID:28344461

  7. Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, John A.; Giffin, Paxton K.; Parsons, Michael S.

    High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikesmore » and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)« less

  8. HDL-cholesterol and physical performance: results from the ageing and longevity study in the sirente geographic area (ilSIRENTE Study).

    PubMed

    Landi, Francesco; Russo, Andrea; Cesari, Matteo; Pahor, Marco; Bernabei, Roberto; Onder, Graziano

    2007-09-01

    High-density lipoprotein (HDL) cholesterol has been hypothesised to be a reliable marker of frailty and poor prognosis among the oldest elderly. We evaluate the relationship of HDL-cholesterol with measures of physical performance, muscle strength, and functional status in older persons aged 80years or older. Data are from baseline evaluation of the ageing and longevity study in the Sirente geographic area (ilSIRENTE study) (n = 364). Physical performance was assessed using the physical performance battery score [short physical performance battery (SPPB)], which is based on three-timed tests: 4-m walking-speed, balance, and chair-stand tests. Muscle strength was measured by hand-grip strength. Analyses of covariance were performed to evaluate the relationship of different HDL-cholesterol levels with physical function. In the unadjusted analyses, physical function (as measured by the 4-m walking-speed, theSPPB score, the basic and instrumental activities of daily living scales scores), but not hand-grip strength, improved significantly as HDL-cholesterol tertiles increased. After adjustment for potential confounders, which included age, gender, living alone, alcohol abuse, physical activity, congestive heart failure, diabetes, cerebrovascular diseases, osteoarthritis, albumin, urea, C-reactive protein and LDL cholesterol, the association of HDL-cholesterol tertiles with the 4-m walking-speed and the SPPB score was still consistent. The present study suggests that among very old subjects living in the community the higher levels of HDL-cholesterol are associated with better functional performance.

  9. View looking west at Test Stand 'A' complex in morning ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking west at Test Stand 'A' complex in morning sun. View shows Monitor Building 4203/E-4 at left, barrier (Building 4216/E-17) to right of 4203/E-4, and Test Stand 'A' tower. Attached structure to lower left of tower is Test Stand 'A' machine room which contained refrigeration equipment. Building in right background with Test Stand 'A' tower shadow on it is Assembly Building 4288/E-89, built in 1984. Row of ground-mounted brackets in foreground was used to carry electrical cable and/or fuel lines. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  10. Participation and argument in legislative debate on statewide smoking restrictions

    PubMed Central

    Apollonio, Dorie E; Lopipero, Peggy; Bero, Lisa A

    2007-01-01

    Background In this paper we review the relationship between participation in legislative hearings, the use of ideological arguments, and the strength of public health legislation using a theoretical construct proposed by E. E. Schattschneider in 1960. Schattschneider argued that the breadth and types of participation in a political discussion could change political outcomes. Methods We test Schattschneider's argument empirically by reviewing the efforts of six states to pass Clean Indoor Air Acts by coding testimony given before legislators, comparing these findings to the different characteristics of each state's political process and the ultimate strength of each state's legislation. Results We find that although greater participation is associated with stronger legislation, there is no clear relationship between the use and type of ideological arguments and eventual outcomes. Conclusion These findings offer validation of a long-standing theory about the importance of political participation, and suggest strategies for public health advocates seeking to establish new legislation. PMID:17953767

  11. Accelerated test system strength models based on Birnbaum-Saunders distribution: a complete Bayesian analysis and comparison.

    PubMed

    Upadhyay, S K; Mukherjee, Bhaswati; Gupta, Ashutosh

    2009-09-01

    Several models for studies related to tensile strength of materials are proposed in the literature where the size or length component has been taken to be an important factor for studying the specimens' failure behaviour. An important model, developed on the basis of cumulative damage approach, is the three-parameter extension of the Birnbaum-Saunders fatigue model that incorporates size of the specimen as an additional variable. This model is a strong competitor of the commonly used Weibull model and stands better than the traditional models, which do not incorporate the size effect. The paper considers two such cumulative damage models, checks their compatibility with a real dataset, compares them with some of the recent toolkits, and finally recommends a model, which appears an appropriate one. Throughout the study is Bayesian based on Markov chain Monte Carlo simulation.

  12. 25. "TEST STAND 1A UTILIZED TO TEST THE ATLAS ICBM", ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. "TEST STAND 1-A UTILIZED TO TEST THE ATLAS ICBM", CROPPED OUT: "DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB." Photo no. 11,371 57; G-AFFTC 15 OCT 57. Looking southwest from below the stand. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  13. Circuit strength training improves muscle strength, functional performance and anthropometric indicators in sedentary elderly women.

    PubMed

    Mazini Filho, Mauro L; Aidar, Felipe J; Gama de Matos, Dihogo; Costa Moreira, Osvaldo; Patrocínio de Oliveira, Cláudia E; de Oliveira Venturini, Gabriela R; Magalhães Curty, Victor; Menezes Touguinha, Henrique; Caputo Ferreira, Maria E

    2017-04-26

    This study aimed to investigate the effects of circuit strength training on the muscle strength, functional autonomy and anthropometric indicators of the elderly. Were included 65 women divided in two groups: strength training (TG, n= 34) and control group (CG, n = 31). The strength-training group was subjected to a circuit shaped training program, three days per week, for a period of 12 weeks. In each training session, the circuit was repeated three times. In each circuit, all exercises wereperformed once, with 8 to 12 repetitions per exercise, with 30-seconds intervals between each exercise. TG showed significantly changes in body composition post 12 weeks, as decreases in body weight (Δ -1.5±1.8 kg) and BMI (Δ-0.57 ±0.74 kg/m²), and decreases in abdominal (Δ -3±1.61 cm), waist (Δ -1 ± 1.61 cm), hip (Δ -2.75±1.44 cm) and waist hip ratio circumference (Δ -0.02 ± 0.15 cm). For functional autonomy, TG showed increases post 12 weeks by 30-second chair stand (Δ 3.5±0.4 reps), six minute walk (Δ60.95±7.91 m), back scratch (Δ 3.2 ± 1.36 cm), and time up and go tests (Δ -1,62 ±0,15s). TG also showed increases in muscle strength post 12 weeks in both leg press (Δ 11±1,29 kg) and lat pulldown (Δ11 ±0,75 Kg). For CG, Body composition, functional autonomy and muscle strength did not improved in any moment. Hence, circuit strength training provides significant improvements inmuscle strength, functional performance and anthropometric indicators in sedentary elderly women.

  14. A comparison of the effects of 6 weeks of traditional resistance training, plyometric training, and complex training on measures of strength and anthropometrics.

    PubMed

    MacDonald, Christopher J; Lamont, Hugh S; Garner, John C

    2012-02-01

    Complex training (CT; alternating between heavy and lighter load resistance exercises with similar movement patterns within an exercise session) is a form of training that may potentially bring about a state of postactivation potentiation, resulting in increased dynamic power (Pmax) and rate of force development during the lighter load exercise. Such a method may be more effective than either modality, independently for developing strength. The purpose of this research was to compare the effects of resistance training (RT), plyometric training (PT), and CT on lower body strength and anthropometrics. Thirty recreationally trained college-aged men were trained using 1 of 3 methods: resistance, plyometric, or complex twice weekly for 6 weeks. The participants were tested pre, mid, and post to assess back squat strength, Romanian dead lift (RDL) strength, standing calf raise (SCR) strength, quadriceps girth, triceps surae girth, body mass, and body fat percentage. Diet was not controlled during this study. Statistical measures revealed a significant increase for squat strength (p = 0.000), RDL strength (p = 0.000), and SCR strength (p = 0.000) for all groups pre to post, with no differences between groups. There was also a main effect for time for girth measures of the quadriceps muscle group (p = 0.001), the triceps surae muscle group (p = 0.001), and body mass (p = 0.001; post hoc revealed no significant difference). There were main effects for time and group × time interactions for fat-free mass % (RT: p = 0.031; PT: p = 0.000). The results suggest that CT mirrors benefits seen with traditional RT or PT. Moreover, CT revealed no decrement in strength and anthropometric values and appears to be a viable training modality.

  15. Siphon flows in isolated magnetic flux tubes. IV - Critical flows with standing tube shocks

    NASA Technical Reports Server (NTRS)

    Thomas, John H.; Montesinos, Benjamin

    1991-01-01

    Critical siphon flows in arched, isolated magnetic flux tubes are studied within the thin flux tube approximation, with a view toward applications to intense magnetic flux concentrations in the solar photosphere. The results of calculations of the strength and position of the standing tube shock in the supercritical downstream branch of a critical siphon flow are presented, as are calculations of the flow variables all along the flux tube and the equilibrium path of the flux tube in the surrounding atmosphere. It is suggested that arched magnetic flux tubes, with magnetic field strength increased by a siphon flow, may be associated with some of the intense, discrete magnetic elements observed in the solar photosphere.

  16. [Fitness and quality of life in kidney transplant recipients: case-control study].

    PubMed

    Hernández Sánchez, Sonsoles; Carrero, Juan J; García López, David; Herrero Alonso, Juan Azael; Menéndez Alegre, Héctor; Ruiz, Jonatan R

    2016-04-15

    We analyzed the levels of fitness, muscle structure and quality of life of adults after kidney transplant and healthy adults. A total of 16 kidney transplant patients and 21 healthy controls performed several fitness test, isokinetic evaluation of knee flexion and extension and ultrasonography muscle thickness assessment. They also completed the quality of life questionnaire SF-36. Physical fitness, muscle structure and quality of life of the kidney transplant recipients were significantly poorer than the controls. The transplant patients performed less well in the "get up and go" and "sit to stand" test (p<.001) as well as in assessments of muscle structure, strength and power. The patients had a poorer score in their quality of life assessments, differing from the controls in domains of physical function, physical role, general health and social function (p<.001). Fitness, strength and muscle mass are diminished in kidney transplant patients, resulting in a poorer quality of life which might entail an increased risk to their health. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  17. Relation between isokinetic muscle strength and functional capacity in recreational athletes with chondromalacia patellae

    PubMed Central

    Yildiz, Y; Aydin, T; Sekir, U; Cetin, C; Ors, F; Alp, K

    2003-01-01

    Objectives: To investigate the effects of isokinetic exercise on pain and functional test scores of recreational athletes with chondromalacia patellae (CMP) and to examine the correlation between isokinetic parameters and functional tests or pain score. Methods: The functional ability of 30 recreational athletes with unilateral CMP was evaluated using six different tests. Pain scores were assessed during daily activities before and after the treatment protocol. Isokinetic exercise sessions were carried out at angular velocities of 60°/s (25–90° range of flexion) and 180°/s (full range). These sessions were repeated three times a week for six weeks. Results: Quadriceps and hamstring peak torque, total work, and endurance ratios had improved significantly after the treatment, as did the functional parameters and pain scores. There was a poor correlation between the extensor endurance ratio and one leg standing test. A moderate correlation between the visual analogue scale and the extensor endurance ratio or flexion endurance ratio was also found. Conclusions: The isokinetic exercise programme used in this study had a positive effect on muscle strength, pain score, and functional ability of knees with CMP. The improvement in the functional capacity did not correlate with the isokinetic parameters. PMID:14665581

  18. Physical function is weakly associated with angiotensin-converting enzyme gene I/D polymorphism in elderly Japanese subjects.

    PubMed

    Yoshihara, A; Tobina, T; Yamaga, T; Ayabe, M; Yoshitake, Y; Kimura, Y; Shimada, M; Nishimuta, M; Nakagawa, N; Ohashi, M; Hanada, N; Tanaka, H; Kiyonaga, A; Miyazaki, H

    2009-01-01

    The turning point in the deterioration of physical function seems to occur between the ages of 70 and 80 years. In particular, muscle strength may decline even more in subjects older than 75. A recent study found that the angiotensin-converting enzyme (ACE) genotype also affects physiological left ventricular hypertrophy. A very limited number of papers have examined genetic differences in resistance and endurance forms of a single sporting discipline. The purpose of this study was to evaluate the relationship between ACE genotype and physical function by controlling the known confounding factors including dental status. We selected 431 subjects who were aged 76 years and did not require special care for their daily activities. We conducted a medical examination, followed by 5 physical function tests, as follows: (1) maximum hand grip strength, (2) maximal isometric knee extensor strength, (3) maximal stepping rate for 10 s, (4) one-leg standing time with eyes open and (5) 10-meter maximum walking speed. Subjects were genotyped for the ACE intron 16 Alu insertion. In addition, serum concentrations of total cholesterol, total protein, IgA and IgG were measured at a commercial laboratory. The Eichner index was used as an indicator of occlusal condition. Multiple linear regression analysis was performed to evaluate the relationship between the ACE gene insertion/deletion (I/D) polymorphism and physical function considering confounding factors. The ACE gene I/D polymorphism was positively associated with hand grip strength and 10-meter maximum walking speed. Betas of hand grip strength were 0.09 for I/D (p = 0.022) and 0.12 for insertion/insertion (I/I; p = 0.004). Betas of 10-meter walking speed were -0.11 for I/D (p = 0.093) and -0.14 for I/I (p = 0.039). Dental status such as Eichner index class C was significantly associated with one-leg standing time with eyes open (beta -0.11; p = 0.028). This study suggests that there is a significant relationship between ACE genotype and physical function. In particular, subjects with the ACE deletion/deletion genotype were associated with upper extremities. Copyright 2009 S. Karger AG, Basel.

  19. Posture, Flexibility and Grip Strength in Horse Riders

    PubMed Central

    Hobbs, Sarah Jane; Baxter, Joanna; Broom, Louise; Rossell, Laura-Ann; Sinclair, Jonathan; Clayton, Hilary M

    2014-01-01

    Since the ability to train the horse to be ambidextrous is considered highly desirable, rider asymmetry is recognized as a negative trait. Acquired postural and functional asymmetry can originate from numerous anatomical regions, so it is difficult to suggest if any is developed due to riding. The aim of this study was therefore to assess symmetry of posture, strength and flexibility in a large population of riders and to determine whether typical traits exist due to riding. 127 right handed riders from the UK and USA were categorized according to years riding (in 20 year increments) and their competition level (using affiliated test levels). Leg length, grip strength and spinal posture were measured and recorded by a physiotherapist. Standing and sitting posture and trunk flexibility were measured with 3-D motion capture technology. Right-left differences were explored in relation to years riding and rider competitive experience. Significant anatomical asymmetry was found for the difference in standing acromion process height for a competition level (−0.07±1.50 cm Intro/Prelim; 0.02±1.31 cm Novice; 0.43±1.27 cm Elementary+; p=0.048) and for sitting iliac crest height for years riding (−0.23±1.36 cm Intro/Prelim; 0.01±1.50 cm Novice; 0.86±0.41 cm Elementary+; p=0.021). For functional asymmetry, a significant interaction was found for lateral bending ROM for years riding x competition level (p=0.047). The demands on dressage riders competing at higher levels may predispose these riders to a higher risk of developing asymmetry and potentially chronic back pain rather than improving their symmetry. PMID:25414745

  20. A-1 Test Stand modifications

    NASA Image and Video Library

    2011-09-14

    Team members check the progress of a liquid nitrogen cold shock test on the A-1 Test Stand at Stennis Space Center on Sept. 15. The cold shock test is used to confirm the test stand's support system can withstand test conditions, when super-cold rocket engine propellant is piped. The A-1 Test Stand is preparing to conduct tests on the powerpack component of the J-2X rocket engine, beginning in early 2012.

  1. 1. TEST AREA 1115, SOUTH PART OF SUPPORT COMPLEX, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TEST AREA 1-115, SOUTH PART OF SUPPORT COMPLEX, LOOKING TO EAST FROM ABOVE BUILDING 8655, THE FUEL STORAGE TANK FARM, IN FOREGROUND SHADOW. AT THE RIGHT IS BUILDING 8660, ELECTRICAL SUBSTATION; TO ITS LEFT IS BUILDING 8663, THE HELIUM COMPRESSION PLANT. THE LIGHT TONED STRUCTURE IN THE MIDDLE DISTANCE, CENTER, IS THE MACHINE SHOP FOR TEST STAND 1-3. IN THE FAR DISTANCE IS TEST STAND 1-A, WITH THE WHITE SPHERICAL TANKS, AND TEST STAND 2-A TO ITS RIGHT. ALONG THE HORIZON FROM FAR LEFT ARE TEST STAND 1-D, TEST STAND 1-C, WATER TANKS ABOVE TEST AREA 1-125, AND TEST STAND 1-B IN TEST AREA 1-120. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  2. Busy test week

    NASA Image and Video Library

    2012-11-08

    NASA recorded a historic week Nov. 5-9, conducting tests on all three stands in the E Test Complex at John C. Stennis Space Center. Inset images show the types of tests conducted on the E-1 Test Stand (right), the E-2 Test Stand (left) and the E-3 Test Stand (center). The E-1 photo is from an early October test and is provided courtesy of Blue Origin. Other photos are from tests conducted the week of Nov. 5.

  3. A-2 Test Stand modification work

    NASA Image and Video Library

    2010-10-27

    John C. Stennis Space Center employees install a new master interface tool on the A-2 Test Stand on Oct. 27, 2010. Until July 2009, the stand had been used for testing space shuttle main engines. With that test series complete, employees are preparing the stand for testing the next-generation J-2X rocket engine being developed. Testing of the new engine is scheduled to begin in 2011.

  4. Nitrogen fertilization decouples roots and microbes: Reductions in belowground carbon allocation limit microbial activity

    NASA Astrophysics Data System (ADS)

    Carrara, J.; Walter, C. A.; Govindarajulu, R.; Hawkins, J.; Brzostek, E. R.

    2017-12-01

    Nitrogen (N) deposition has enhanced the ability of trees to capture atmospheric carbon (C). The effect of elevated N on belowground C cycling, however, is variable and response mechanisms are largely unknown. Recent research has highlighted distinct differences between ectomycorrhizal (ECM) and arbuscular mycorrhizal (AM) trees in the strength of root-microbial interactions. In particular, ECM trees send more C to rhizosphere microbes to stimulate enzyme activity and nutrient mobilization than AM trees, which primarily rely on saprotrophic microbes to mobilize N. As such, we hypothesized that N fertilization would weaken root-microbial interactions and soil decomposition in ECM stands more than in AM stands. To test this hypothesis, we measured root-microbial interactions in ECM and AM plots in two long-term N fertilization studies, the Fernow Experimental Forest, WV and Bear Brook Watershed, ME. We found that N fertilization led to declines in plant C allocation belowground to fine root biomass, branching, and root exudation in ECM stands to a greater extent than in AM stands. As ECM roots are tightly coupled to the soil microbiome through energy and nutrient exchange, reductions in belowground C allocation were mirrored by shifts in microbial community composition and reductions in fungal gene expression. These shifts were accompanied by larger reductions in fungal-derived lignolytic and hydrolytic enzyme activity in ECM stands than in AM stands. In contrast, as the AM soil microbiome is less reliant on trees for C and are more adapted to high inorganic nutrient environments, the soil metagenome and transcriptome were more resilient to decreases in belowground C allocation. Collectively, our results indicate the N fertilization decoupled root-microbial interactions by reducing belowground carbon allocation in ECM stands. Thus, N fertilization may reduce soil turnover and increase soil C storage to a greater extent in forests dominated by ECM than AM trees.

  5. Long-term effects of a 12-week exercise training program on clinical outcomes in idiopathic pulmonary fibrosis.

    PubMed

    Vainshelboim, Baruch; Oliveira, Jose; Fox, Benjamin Daniel; Soreck, Yafit; Fruchter, Oren; Kramer, Mordechai Reuven

    2015-06-01

    Idiopathic pulmonary fibrosis (IPF) is a chronic, devastating, lung disease, with few therapeutic options. Data are limited with respect to the long-term effect of exercise training (ET) in IPF. This study sought to evaluate the long-term effects of a 12-week ET program on clinical outcomes in IPF patients. Thirty-four IPF patients were randomly allocated to ET or control groups. ET group participated in a 12-week supervised exercise program, while the control group continued with regular medical treatment alone. Exercise capacity, 30 s-chair-stand test for leg strength, dyspnea, and Saint George's Respiratory Questionnaire (SGRQ) for quality of life (QOL) were assessed at baseline and re-evaluated at 11 months from baseline. In addition, at 30-month time point from baseline, the impact of the 12-week intervention was analyzed with respect to survival and cardio-respiratory-related hospitalizations. Thirty-two patients completed the 12-week intervention and 28 patients (14 in each group) were re-evaluated. At 11-month follow-up, no significant differences between the groups and time effect were demonstrated for most outcomes. ET group showed preserved values at the baseline level while the control group showed a trend of deterioration. Only the 30 s-chair-stand test (mean difference 3 stands, p = 0.01) and SGRQ (mean difference -6 units, p = 0.037) were significantly different between the groups. At 30 months, the survival analysis showed three deaths, eight hospitalizations occurred in the control group versus one death, one lung transplantation and seven hospitalizations in the ET group, with no significant differences between groups. At 11-month follow-up, the 12-week ET program showed clinical outcomes were preserved at baseline levels with some maintenance of improvements in leg strength and QOL in the ET group. The control group showed a trend of deterioration in the outcomes. At 30 months, the 12-week ET program did not show benefits in prognosis although the study was underpowered to detect such differences. We suggest including ET as a long-term continued treatment and as a core component of pulmonary rehabilitation programs for IPF patients.

  6. 38. HISTORIC CLOSER VIEW LOOKING WEST OF THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. HISTORIC CLOSER VIEW LOOKING WEST OF THE TEST STAND AND ROCKET DURING TEST FIRING NUMBER 10. NOTE THE NUMBER ALONG THE TOP RAIL OF THE STAND JUST TO THE RIGHT OF THE ROCKET, THIS NUMBER INDICATES WHAT NUMBER TEST IS BEING CONDUCTED. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  7. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  8. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  9. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  10. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  11. 49 CFR 210.33 - Operation standards (switcher locomotives, load cell test stands, car coupling operations, and...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... cell test stands, car coupling operations, and retarders). 210.33 Section 210.33 Transportation Other... (switcher locomotives, load cell test stands, car coupling operations, and retarders). (a) Measurement on receiving property of the noise emission levels from switcher locomotives, load cell test stands, car...

  12. Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals.

    PubMed

    Nakamura, Keisuke; Ohira, Masayoshi; Yokokawa, Yoshiharu; Nagasawa, Yuya

    2015-12-01

    Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min(-1)·kg(-1)) and the CE test (18.4 ± 1.8 mL·min(-1)·kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min(-1)·kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 ± 10 bpm) and the CE test (126 ± 13 bpm) were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults. Key pointsThe ISTS is a simple test that varies only according to the frequency of standing up, and requires only a small space and a chair.The ISTS with arm support is valid and reproducible, and is a safe test for evaluating AT in healthy young adults.For evaluating the AT, the ISTS may serve as a valid alternative to conventional CPX, using either a cycle ergometer or treadmill, in cases where the latter methods are difficult to implement.

  13. A-1 Test Stand work

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Employees at NASA's John C. Stennis Space Center work to maneuver a structural steam beam into place on the A-1 Test Stand on Jan. 13. The beam was one of several needed to form the thrust takeout structure that will support a new thrust measurement system being installed on the stand for future rocket engine testing. Once lifted onto the stand, the beams had to be hoisted into place through the center of the test stand, with only two inches of clearance on each side. The new thrust measurement system represents a state-of-the-art upgrade from the equipment installed more than 40 years ago when the test stand was first constructed.

  14. Historic tests

    NASA Image and Video Library

    2012-08-16

    Two large-engine tests were conducted simultaneously for the first time at Stennis Space Center on Aug. 16. A plume on the left indicates a test on the facility's E-1 Test Stand. On the right, a finger of fire indicates a test under way on the A-1 Test Stand. In another first, both tests were conducted by female engineers. The image was taken from atop the facility's A-2 Test Stand, offering a panoramic view that includes the new A-3 Test Stand under construction to the left.

  15. Experimental measurement of dolphin thrust generated during a tail stand using DPIV

    NASA Astrophysics Data System (ADS)

    Wei, Timothy; Fish, Frank; Williams, Terrie; Wu, Vicki; Sherman, Erica; Misfeldt, Mitchel; Ringenberg, Hunter; Rogers, Dylan

    2016-11-01

    The thrust generated by dolphins doing tail stands was measured using DPIV. The technique entailed measuring vortex strength associated with the tail motion and correlating it to above water video sequences showing the amount of the dolphin's body that was being lifted out of the water. The underlying drivers for this research included: i) understanding the physiology, hydrodynamics and efficiency of dolphin locomotion, ii) developing non-invasive measurement techniques for studying marine swimming and iii) quantifying the actual propulsive capabilities of these animals. Two different bottlenose dolphins at the Long Marine Lab at UC-Santa Cruz were used as test subjects. Application of the Kutta-Joukowski Theorem on measured vortex circulations yielded thrust values that were well correlated with estimates of dolphin body weight being supported above water. This demonstrates that the tail motion can be interpreted as a flapping hydrofoil that can generate a sustained thrust roughly equal to the dolphin's weight. Videos of DPIV measurements overlaid with the dolphins will be presented along with thrust/weight data.

  16. What physical performance measures predict incident cognitive decline among intact older adults? A 4.4year follow up study.

    PubMed

    Veronese, Nicola; Stubbs, Brendon; Trevisan, Caterina; Bolzetta, Francesco; De Rui, Marina; Solmi, Marco; Sartori, Leonardo; Musacchio, Estella; Zambon, Sabina; Perissinotto, Egle; Crepaldi, Gaetano; Manzato, Enzo; Sergi, Giuseppe

    2016-08-01

    Reductions in physical performance, cognitive impairment (CI) and decline (CD), are common in older age, but few prospective cohort studies have considered the relationship between these domains. In this study we investigated whether reduced physical performance and low handgrip/lower limbs strength, could predict a higher incidence of CI/CD during a 4-year follow-up among a cohort of elderly individuals. From 3099 older community-dwelling individuals initially enrolled in the Progetto Veneto Anziani (PRO.V.A.) study, 1249 participants without CI at the baseline were included (mean age 72.2years, 59.5% females). Physical performance measures included the Short Physical Performance Battery (SPPB), 4m gait speed, chair stands time, leg extension and flexion, handgrip strength, and 6-Minute Walking Test (6MWT), categorized in gender-specific tertiles. CI was defined as a Mini-Mental State Examination (MMSE) score below 24; CD a decline of 3 or more points in the MMSE without CI. At baseline, participants developing CI during follow-up scored significantly worse across all physical performance measures compared to those that retained normal cognitive status. After adjusting for potential confounders, a significant trend for MMSE changes was noted for all physical performance tests, except for the SPPB and chair stands time. Multinomial logistic regression revealed that slow gait speed at baseline significantly predicted CD at follow up. Poor SPPB performance and slower gait speed predicted the onset of CI at the follow-up. In conclusion, slow walking speed appears to be the best independent predictor of poor cognitive status over a 4.4-year follow-up, while other items of SPPB were also significantly associated with CI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Maximum occlusal force and physical performance in the oldest old: the Tokyo oldest old survey on total health.

    PubMed

    Iinuma, Toshimitsu; Arai, Yasumichi; Fukumoto, Motoko; Takayama, Michiyo; Abe, Yukiko; Asakura, Keiko; Nishiwaki, Yuji; Takebayashi, Toru; Iwase, Takashi; Komiyama, Kazuo; Gionhaku, Nobuhito; Hirose, Nobuyoshi

    2012-01-01

    To elucidate the independent relationship between masticatory and physical performance in community-living oldest old people (mean age ± standard deviation 87.8 ± 2.2, range 85-102). Cross-sectional analysis. University research center or home-based examination. Four hundred eighty-nine community-living individuals (219 men, 270 women) aged 85 and older. Maximum occlusal force (MOF) was measured using an occlusal force measuring device. Sociodemographic and functional factors, oral health, comorbidities, blood chemistry, lower extremity performance, and handgrip strength were assessed. Blood chemistry analyses included serum albumin, C-reactive protein, interleukin (IL)-6, and total and free testosterone. MOF was significantly associated with age, body mass index, and cognitive impairment in men but not in women. Comorbidities and blood chemistry were not associated with MOF except for a significant association with IL-6 concentration in women. In a multivariate model adjusted for various confounders, lower MOF was associated with greater risk for poor performance on the timed up and go (TUG) test in men and women (men: odds ratio (OR)=2.34, 95% confidence interval (CI)=1.02-5.38; women: OR=2.44, 95% CI=1.12-5.33). MOF was similarly associated with performance in chair standing, one-leg standing, and handgrip strength only in men. These associations remained after adjustment for number of natural teeth. MOF was strongly and independently associated with all measures of physical performance in men and with the TUG test in women after adjustment for various confounders, suggesting that age-related declines in masticatory and skeletal muscle functions share common mechanistic pathways in older age, particularly in men. © 2011, Copyright the Authors Journal compilation © 2011, The American Geriatrics Society.

  18. In hip osteoarthritis, Nordic Walking is superior to strength training and home-based exercise for improving function.

    PubMed

    Bieler, T; Siersma, V; Magnusson, S P; Kjaer, M; Christensen, H E; Beyer, N

    2017-08-01

    This observer-blinded, randomized controlled trial compared the short- and long-term effects of 4 months of supervised strength training (ST) in a local fitness center, supervised Nordic Walking (NW) in a local park, and unsupervised home-based exercise (HBE, control) on functional performance in 60+-year-old persons (n = 152) with hip osteoarthritis (OA) not awaiting hip replacement. Functional performance [i.e., 30-s chair stand test (primary outcome), timed stair climbing, and 6-min walk test] and self-reported outcomes (i.e., physical function, pain, physical activity level, self-efficacy, and health-related quality of life) were measured at baseline and at 2, 4, and 12 months. Based on intention-to-treat-analyses improvements [mean (95% CI)] after intervention in number of chair stands were equal in all three groups at 4 months [ST: 0.9 (0.2-1.6), NW: 1.9 (0.8-3.0), HBE: 1.1 (0.1-2.0)] but greater in the NW group [1.4 (0.02-2.8)] than in the ST group at 12 months. Generally, improvements in functional performance were greater (P < 0.001-P < 0.03) after NW compared with HBE and ST at all follow-up time points. Furthermore, NW was superior (P < 0.01) to HBE for improving vigorous physical activity and to both ST and HBE for improving (P < 0.01) mental health. These data suggest that NW is the recommended exercise modality compared with ST and HBE. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. 24. SATURN V Fl ENGINE TEST FIRING ON TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. SATURN V F-l ENGINE TEST FIRING ON TEST STAND 1A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  20. Stand for testing the electrical race car engine

    NASA Astrophysics Data System (ADS)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  1. Effects of mini trampoline exercise on male gymnasts' physiological parameters: a pilot study.

    PubMed

    Karakollukçu, M; Aslan, C S; Paoli, A; Bianco, A; Sahin, F N

    2015-01-01

    There are limited studies that indicate the effects of trampoline exercise on strength and other physiological parameters. This study aims to determine whether twelve weeks of trampoline exercise would have any effects on the physical and physiological parameters of male gymnasts. A number of 20 intercollegiate competitive male gymnasts (as experimental group) and 20 non-athlete male (as control group) participated voluntarily. Their anthropometric characteristics and the anaerobic power were measured and their back strength, vertical jump, standing long jump and 20 meter sprint performances were measured. As a result; whereas 12 weeks of trampoline exercise improved standing long jump (before 242.35±3.40 cm; after 251.70±2.95 cm) and also vertical jump, 20 meter sprint speed and anaerobic power of subjects. We did not observe significant changes on back strength performances (before 148.32±5.73 kg; after 148.10±5.71). The trampoline exercise protocol improved significantly speed, jump and anaerobic performances of the experimental group, while did not induced any changes on back strength performances. More studies are necessary to confirm the interesting results coming from this pilot intervention.

  2. A best practice fall prevention exercise program to improve balance, strength / power, and psychosocial health in older adults: study protocol for a randomized controlled trial.

    PubMed

    Gschwind, Yves J; Kressig, Reto W; Lacroix, Andre; Muehlbauer, Thomas; Pfenninger, Barbara; Granacher, Urs

    2013-10-09

    With increasing age neuromuscular deficits (e.g., sarcopenia) may result in impaired physical performance and an increased risk for falls. Prominent intrinsic fall-risk factors are age-related decreases in balance and strength / power performance as well as cognitive decline. Additional studies are needed to develop specifically tailored exercise programs for older adults that can easily be implemented into clinical practice. Thus, the objective of the present trial is to assess the effects of a fall prevention program that was developed by an interdisciplinary expert panel on measures of balance, strength / power, body composition, cognition, psychosocial well-being, and falls self-efficacy in healthy older adults. Additionally, the time-related effects of detraining are tested. Healthy old people (n = 54) between the age of 65 to 80 years will participate in this trial. The testing protocol comprises tests for the assessment of static / dynamic steady-state balance (i.e., Sharpened Romberg Test, instrumented gait analysis), proactive balance (i.e., Functional Reach Test; Timed Up and Go Test), reactive balance (i.e., perturbation test during bipedal stance; Push and Release Test), strength (i.e., hand grip strength test; Chair Stand Test), and power (i.e., Stair Climb Power Test; countermovement jump). Further, body composition will be analysed using a bioelectrical impedance analysis system. In addition, questionnaires for the assessment of psychosocial (i.e., World Health Organisation Quality of Life Assessment-Bref), cognitive (i.e., Mini Mental State Examination), and fall risk determinants (i.e., Fall Efficacy Scale - International) will be included in the study protocol. Participants will be randomized into two intervention groups or the control / waiting group. After baseline measures, participants in the intervention groups will conduct a 12-week balance and strength / power exercise intervention 3 times per week, with each training session lasting 30 min. (actual training time). One intervention group will complete an extensive supervised training program, while the other intervention group will complete a short version ('3 times 3') that is home-based and controlled by weekly phone calls. Post-tests will be conducted right after the intervention period. Additionally, detraining effects will be measured 12 weeks after program cessation. The control group / waiting group will not participate in any specific intervention during the experimental period, but will receive the extensive supervised program after the experimental period. It is expected that particularly the supervised combination of balance and strength / power training will improve performance in variables of balance, strength / power, body composition, cognitive function, psychosocial well-being, and falls self-efficacy of older adults. In addition, information regarding fall risk assessment, dose-response-relations, detraining effects, and supervision of training will be provided. Further, training-induced health-relevant changes, such as improved performance in activities of daily living, cognitive function, and quality of life, as well as a reduced risk for falls may help to lower costs in the health care system. Finally, practitioners, therapists, and instructors will be provided with a scientifically evaluated feasible, safe, and easy-to-administer exercise program for fall prevention.

  3. View east northeast at Test Stand 'A' complex from road, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View east northeast at Test Stand 'A' complex from road, showing Test Stand 'C' test tower in left background (Building 4217/E-18). Curved I-beam labeled '3-ton' is for small traveling hoist. Fuel tanks, propellant lines, and control panels have been removed from tower. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  4. Combined isometric and vibration training does not enhance strength beyond that of isometric training alone.

    PubMed

    Fisher, J; Van-Dongen, M; Sutherland, R

    2014-10-08

    Research considering combined vibration and strength training is extensive yet results are equivocal. However, to date there appears no research which has considered the combination of both direct vibration and whole---body vibration when used in an isometric deadlift position. The aims of this study were to compare groups performing isometric training with and without direct and whole---body vibration. Twenty four participants (19---24 years) were randomly divided into: isometric training with vibration (ST+VT: n=8), isometric training without vibration (ST: n=8), and control (CON: n=8). Within the training groups participants trained twice per week, for 6 weeks, performing 6---sets of maximal isometric deadlift contractions, increasing in duration from 30 seconds to 40 seconds (weeks 1---6). Hip and knee angle was maintained at 60° and 110°, respectively for both testing and training. Training sessions for ST+VT were identical to ST with the addition of a direct vibratory stimulus through hand---held straps and whole---body vibration via standing on vibration a platform. The amplitude remained constant (2mm) throughout the intervention whilst the frequency increased from 35Hz to 50Hz. Pre--- and post---test isometric strength was measured using an isometric deadlift dynamometer. Results revealed significant increases in isometric strength for both ST+VT (p < 0.001, 23.8%) and ST (p < 0.001, 32.5%) compared to CON, with no significant differences between ST+VT and ST training groups. The present study provides evidence to suggest that there are no greater gains to be incurred by the addition of a vibratory stimulus to traditional strength training.

  5. Combined isometric and vibration training does not enhance strength beyond that of isometric training alone.

    PubMed

    Fisher, J; Van-Dongen, M; Sutherland, R

    2015-09-01

    Research considering combined vibration and strength training is extensive yet results are equivocal. However, to date there appears no research which has considered the combination of both direct vibration and whole-body vibration when used in an isometric deadlift position. The aim of this study was to compare groups performing isometric training with and without direct and whole-body vibration. Twenty four participants (19-24 years) were randomly divided into: isometric training with vibration (ST+VT: N.=8), isometric training without vibration (ST: N.=8), and control (CON: N.=8). Within the training groups participants trained twice per week, for 6 weeks, performing 6-sets of maximal isometric deadlift contractions, increasing in duration from 30 seconds to 40 seconds (weeks 1-6). Hip and knee angle was maintained at 60° and 110°, respectively for both testing and training. Training sessions for ST+VT were identical to ST with the addition of a direct vibratory stimulus through hand-held straps and whole-body vibration via standing on vibration a platform. The amplitude remained constant (2 mm) throughout the intervention whilst the frequency increased from 35Hz to 50Hz. Pre- and post-test isometric strength was measured using an isometric deadlift dynamometer. Results revealed significant increases in isometric strength for both ST+VT (P<0.001, 23.8%) and ST (P<0.001, 32.5%) compared to CON, with no significant differences between ST+VT and ST training groups. The present study provides evidence to suggest that there are no greater gains to be incurred by the addition of a vibratory stimulus to traditional strength training.

  6. The effects of Tai-Chi in conjunction with thera-band resistance exercise on functional fitness and muscle strength among community-based older people.

    PubMed

    Lin, Shu-Fen; Sung, Huei-Chuan; Li, Tzai-Li; Hsieh, Tsung-Cheng; Lan, Hsiao-Chin; Perng, Shoa-Jen; Smith, Graeme D

    2015-05-01

    The aim of this study was to investigate the effects of Tai-Chi in conjunction with thera-band resistance exercise on functional fitness and muscle strength in community-based older people. Tai-Chi is known to improve functional fitness in older people. Tai-Chi is usually performed with free hands without resistance training and usually focuses on training lower limbs. To date, no study has examined the use of Tai-Chi in conjunction with thera-band resistance exercise in this population. Cluster randomised trial design. Older people at six senior day care centres in Taiwan were assigned to thera-band resistance exercise or control group using a cluster randomisation. The thera-band resistance exercise group (n = 48) received sixty minute thera-band resistance exercise twice weekly for a period of 16 weeks. The control group (n = 47) underwent routine activities in the day care centre, receiving no Tai-Chi or resistance exercise. After receiving the thera-band resistance exercise, intervention participants displayed a significant increase in muscle strength of upper and lower extremities. Significant improvements were recorded on most measures of the Senior Fitness Test, with the exception of the chair-stand and back-scratch test. Thera-band resistance exercise has the potential to improve functional fitness and muscle strength in community-based older people. Thera-band resistance exercise potentially offers a safe and appropriate form of physical activity that nursing staff can easily incorporate into the daily routine of older people in day care centres, potentially improving functional performance and muscle strength. © 2015 John Wiley & Sons Ltd.

  7. 1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW NORTHEAST, LEFT TO RIGHT COLD CALIBRATION TEST STAND COLD CALIBRATION BLOCKHOUSE IN FOREGROUND. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL

  8. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Stennis Space Center employees have installed liquid oxygen and liquid hydrogen tanks atop the A-3 Test Stand, raising the structure to its full 300-foot height. The stand is being built to test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space. The A-3 Test Stand is scheduled for completion and activation in 2013.

  9. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  10. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  11. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  12. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  13. 40 CFR 201.27 - Procedures for: (1) Determining applicability of the locomotive load cell test stand standard and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applicability of the locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving property; (2) measurement of locomotive load cell test stands more than 120 meters... locomotive load cell test stand standard and switcher locomotive standard by noise measurement on a receiving...

  14. Photographic copy of photograph, aerial view looking north and showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of photograph, aerial view looking north and showing Test Stand 'A' (at bottom), Test Stand 'B' (upper right), and a portion of Test Stand 'C' (top of view). Compare HAER CA-163-1 and 2 and note addition of liquid nitrogen storage tank (Building 4262/E-63) to west of Test Stand 'C' as well as various ancillary facilities located behind earth barriers near Test Stand 'C.' (JPL negative no. 384-3006-A, 12 December 1961) - Jet Propulsion Laboratory Edwards Facility, Edwards Air Force Base, Boron, Kern County, CA

  15. Effects of free leucine supplementation and resistance training on muscle strength and functional status in older adults: a randomized controlled trial

    PubMed Central

    Trabal, Joan; Forga, Maria; Leyes, Pere; Torres, Ferran; Rubio, Jordi; Prieto, Esther; Farran-Codina, Andreu

    2015-01-01

    Objective To assess the effect of free leucine supplementation combined with resistance training versus resistance training only on muscle strength and functional status in older adults. Methods This was a randomized, double-blind, placebo-controlled, parallel study with two intervention groups. Thirty older adults were randomly assigned to receive either 10 g leucine/day (leucine group [LG], n=15) or a placebo (control group [CG], n=15), plus resistance training over a 12-week period. Maximal overcoming isometric leg strength, functional status, nutritional status, body composition, health-related quality of life, depression, and dietary intake were assessed at 4 and 12 weeks. Missing data at 12 weeks were handled using mixed models for repeated measurements for data imputation. Results Twenty-four subjects completed the 4-week assessment and eleven completed the 12-week intervention. Clinically significant gains were found in isometric leg strength at both assessment time points. Analysis of the effect size also showed how participants in LG outperformed those in CG for chair stands and the timed up and go test. No significant changes were observed for the rest of the outcomes. Conclusion Our combined analysis showed moderate changes in isometric leg muscle strength and certain components of functional status. The magnitude of changes found on these outcomes should be qualified as a positive effect of the concomitant intervention. PMID:25926725

  16. Effects of free leucine supplementation and resistance training on muscle strength and functional status in older adults: a randomized controlled trial.

    PubMed

    Trabal, Joan; Forga, Maria; Leyes, Pere; Torres, Ferran; Rubio, Jordi; Prieto, Esther; Farran-Codina, Andreu

    2015-01-01

    To assess the effect of free leucine supplementation combined with resistance training versus resistance training only on muscle strength and functional status in older adults. This was a randomized, double-blind, placebo-controlled, parallel study with two intervention groups. Thirty older adults were randomly assigned to receive either 10 g leucine/day (leucine group [LG], n=15) or a placebo (control group [CG], n=15), plus resistance training over a 12-week period. Maximal overcoming isometric leg strength, functional status, nutritional status, body composition, health-related quality of life, depression, and dietary intake were assessed at 4 and 12 weeks. Missing data at 12 weeks were handled using mixed models for repeated measurements for data imputation. Twenty-four subjects completed the 4-week assessment and eleven completed the 12-week intervention. Clinically significant gains were found in isometric leg strength at both assessment time points. Analysis of the effect size also showed how participants in LG outperformed those in CG for chair stands and the timed up and go test. No significant changes were observed for the rest of the outcomes. Our combined analysis showed moderate changes in isometric leg muscle strength and certain components of functional status. The magnitude of changes found on these outcomes should be qualified as a positive effect of the concomitant intervention.

  17. Development, test-retest reliability, and construct validity of the resistance training skills battery.

    PubMed

    Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D

    2014-05-01

    The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.

  18. Comparison of Muscle Mass Indices Using Computed Tomography or Dual X-Ray Absorptiometry for Predicting Physical Performance in Hemodialysis Patients.

    PubMed

    Kang, Seok Hui; Lee, Hyun Seok; Lee, Sukyung; Cho, Ji-Hyung; Kim, Jun Chul

    2017-01-01

    Our study aims to evaluate the association between thigh muscle cross-sectional area (TMA) using computed tomography (CT), or appendicular skeletal muscle mass (ASM) using dual energy X-ray absorptiometry (DEXA), and physical performance levels in hemodialysis (HD) patients. Patients were included if they were on HD for ≥6 months (n = 84). ASM and TMA were adjusted to body weight (BW, kg) or height2 (Ht2, m2). Each participant performed a short physical performance battery test (SPPB), a sit-to-stand for 30 second test (STS30), a 6-minute walk test (6-MWT), a timed up and go test (TUG), and hand grip strength (HGS) test. Correlation coefficients for SPPB, GS, 5STS, STS30, 6-MWT, and TUG were highest in TMA/BW. Results from partial correlation or linear regression analyses displayed similar trends to those derived from Pearson's correlation analyses. An increase in TMA/BW or TMA/Ht2 was associated with a decreased odds ratio of low SPPB, GS, or HGS in multivariate analyses. Indices using DEXA were associated with a decreased odds ratio of a low HGS only in multivariate analysis. TMA indices using CT may be more valuable in predicting physical performance or strength in HD patients. © 2017 The Author(s). Published by S. Karger AG, Basel.

  19. 23. "A CAPTIVE ATLAS MISSILE EXPLODED DURING THE TEST ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. "A CAPTIVE ATLAS MISSILE EXPLODED DURING THE TEST ON TEST STAND 1-A, 27 MARCH 1959, PUTTING THAT TEST STAND OUT-OF-COMMISSION. STAND WAS NOT REPAIRED FOR THE ATLAS PROGRAM BUT TRANSFERRED TO ROCKETDYNE AND MODIFIED FOR THE F-l ENGINE PROGRAM." - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  20. Correlation between nutritional status and comprehensive physical performance measures among older adults with undernourishment in residential institutions.

    PubMed

    Singh, Devinder K A; Manaf, Zahara A; Yusoff, Noor Aini M; Muhammad, Nur A; Phan, Mei Fang; Shahar, Suzana

    2014-01-01

    The consequences of combined undernourishment and decreased physical performance in older adults are debilitating and increases cost of care. To date, the information regarding the association between nutritional status and physical performance does not provide a complete picture. Most studies used limited or self-reported measures to evaluate physical performance. The objective of this study was to examine the correlation between nutritional status and comprehensive physical performance measures among undernourished older adults who reside in residential institutions. Forty-seven older adults (26 males, 21 females) aged ≥ 60 (69.23 ± 8.63) years who were identified as undernourished from two residential institutions participated in this study. A battery of physical performance tests (10 m gait speed test, dominant hand grip strength test, timed five-repetition sit-to-stand test, ten step test, arm curl test, scratch test, and respiratory muscle strength test), biochemical profiles (serum albumin, hemoglobin, serum ferritin, and prealbumin levels), and falls risk using the short-form Physiological Profile Approach were performed. The Functional Ability Questionnaire and Geriatric Depression Scale were also administered. The results demonstrated that generally older adults with undernourishment scored poorly on the physical performance tests, had depression, and a high risk of falls. Biochemical results demonstrated that 10.9% of the participants were anemic, 63% had hypoalbuminemia (<3.5 g/dL), and 21.7% were at risk of protein energy malnutrition with prealbumin level (100-170 mg/L). A significant correlation (P<0.05) was demonstrated between hand grip strength and ferritin, between self-reported mobility dependence and prealbumin levels, and between self-reported mobility tiredness and body mass index. These results confirm that older adults with undernutrition have poor physical function, higher falls risk, and depression. Clinically, overall health that includes nutritional status, physical function, and depression level should be taken into consideration in the assessment and treatment of older adults residing at residential institutions.

  1. 8. TEST STAND 15, INVERTED ENGINE FIRING TEST, CIRCA 1963. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. TEST STAND 1-5, INVERTED ENGINE FIRING TEST, CIRCA 1963. Original is a color print. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  2. A-3 Test Stand work continues

    NASA Image and Video Library

    2011-04-22

    Stennis Space Center employees continue work on the A-3 Test Stand test cell. The stand is being built to test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space.

  3. 9. COLD CALIBRATION TEST STAND (H1) FROM LEFT TO RIGHT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. COLD CALIBRATION TEST STAND (H-1) FROM LEFT TO RIGHT - WORK BENCH, CONTROL PANEL, CHEMICAL TANK. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL

  4. 5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. Edwards ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. EAST SIDE, TEST STAND AND ITS SUPERSTRUCTURE. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  5. PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PERSPECTIVE VIEW LOOKING NORTHEAST AT THE TEST STAND, NOTE THE SERVICE AND SUPPORT BUILDINGS TO THE LEFT AND RIGHT OF THE TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  6. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    PubMed

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  7. The impact of dynamic balance measures on walking performance in multiple sclerosis.

    PubMed

    Fritz, Nora E; Marasigan, Rhul Evans R; Calabresi, Peter A; Newsome, Scott D; Zackowski, Kathleen M

    2015-01-01

    Static posture imbalance and gait dysfunction are common in individuals with multiple sclerosis (MS). Although the impact of strength and static balance on walking has been examined, the impact of dynamic standing balance on walking in MS remains unclear. To determine the impact of dynamic balance, static balance, sensation, and strength measures on walking in individuals with MS. Fifty-two individuals with MS (27 women; 26 relapsing-remitting; mean age = 45.6 ± 10.3 years; median Expanded Disability Status Scale score = 3.5) participated in posturography testing (Kistler-9281 force plate), hip flexion, hip extension, ankle dorsiflexion strength (Microfet2 hand-held dynamometer), sensation (Vibratron II), and walk velocity (Optotrak Motion Analysis System). Analyses included, Mann-Whitney, Spearman correlation coefficients, and multiple regression. All measures were abnormal in individuals with MS when compared with norms (P < .05). Static balance (eyes open, feet together [EOFT]), anterior-posterior (AP) dynamic sway, and hip extension strength were strongly correlated with walking velocity (AP sway r = 0.68; hip extension strength r = 0.73; EOFT r = -0.40). Together, AP dynamic sway (ρr = 0.71; P < .001), hip extension strength (ρr = 0.54; P < .001), and EOFT static balance (ρr = -0.41; P = .01) explained more than 70% of the variance in walking velocity (P < .001). AP dynamic sway affects walking performance in MS. A combined evaluation of dynamic balance, static balance, and strength may lead to a better understanding of walking mechanisms and the development of strategies to improve walking. © The Author(s) 2014.

  8. CLOSEUP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CLOSE-UP VIEW LOOKING SOUTH AT THE SATURN I TEST STAND, NOTE THE INTERPRETIVE SIGN EXPLAINING THE HISTORIC NATURE OF THE SATURN I TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  9. 43. HISTORIC VIEW LOOKING SOUTHWEST AT THE TEST STAND WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. HISTORIC VIEW LOOKING SOUTHWEST AT THE TEST STAND WITH A REDSTONE ROCKET BEING FUELED AND PREPARED FOR TESTING. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  10. Do muscle mass, muscle density, strength, and physical function similarly influence risk of hospitalization in older adults?

    PubMed

    Cawthon, Peggy Mannen; Fox, Kathleen M; Gandra, Shravanthi R; Delmonico, Matthew J; Chiou, Chiun-Fang; Anthony, Mary S; Sewall, Ase; Goodpaster, Bret; Satterfield, Suzanne; Cummings, Steven R; Harris, Tamara B

    2009-08-01

    To examine the association between strength, function, lean mass, muscle density, and risk of hospitalization. Prospective cohort study. Two U.S. clinical centers. Adults aged 70 to 80 (N=3,011) from the Health, Aging and Body Composition Study. Measurements were of grip strength, knee extension strength, lean mass, walking speed, and chair stand pace. Thigh computed tomography scans assessed muscle area and density (a proxy for muscle fat infiltration). Hospitalizations were confirmed by local review of medical records. Negative binomial regression models estimated incident rate ratios (IRRs) of hospitalization for race- and sex-specific quartiles of each muscle and function parameter separately. Multivariate models adjusted for age, body mass index, health status, and coexisting medical conditions. During an average 4.7 years of follow-up, 1,678 (55.7%) participants experienced one or more hospitalizations. Participants in the lowest quartile of muscle density were more likely to be subsequently hospitalized (multivariate IRR=1.47, 95% confidence interval (CI)=1.24-1.73) than those in the highest quartile. Similarly, participants with the weakest grip strength were at greater risk of hospitalization (multivariate IRR=1.52, 95% CI=1.30-1.78, Q1 vs. Q4). Comparable results were seen for knee strength, walking pace, and chair stands pace. Lean mass and muscle area were not associated with risk of hospitalization. Weak strength, poor function, and low muscle density, but not muscle size or lean mass, were associated with greater risk of hospitalization. Interventions to reduce the disease burden associated with sarcopenia should focus on increasing muscle strength and improving physical function rather than simply increasing lean mass.

  11. 3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  12. 1. Credit PSR. This view displays the north and west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Credit PSR. This view displays the north and west facades of Test Stand "G" (Vibration Facility) as seen when looking east southeast (110°). Test Stand "G" no longer houses the vibrator; it now houses an autoclave due to the changing nature of the testing work. The Vibration Facility was Test Stand "G"'s historic function. Test Stand "E" is at the far right. The Vibration Facility subjected motor and engine assemblies to various vibration patterns in order to simulate flight conditions and evaluate the durability of engine and motor designs. - Jet Propulsion Laboratory Edwards Facility, Test Stand G, Edwards Air Force Base, Boron, Kern County, CA

  13. Statins, Angiotensin-Converting Enzyme Inhibitors and Physical Performance in Older Women

    PubMed Central

    Gray, Shelly L.; Aragaki, Aaron K.; LaMonte, Michael J.; Cochrane, Barbara B.; Kooperberg, Charles; Robinson, Jennifer G.; Woods, Nancy F.; LaCroix, Andrea Z.

    2012-01-01

    OBJECTIVES Angiotensin-converting enzyme (ACE) inhibitor and statin medications may preserve skeletal muscle. We examined associations between each medication class and baseline and mean annual change in physical performance measures and muscle strength in older women. DESIGN Prospective cohort study PARTICIPANTS Participants from the Women’s Health Initiative Clinical Trials who were aged 65–79 at baseline and had physical performance measures, self-report of health insurance and no prior history of stroke or congestive heart failure were included (n=5777). Women were recruited between 1993 and 1998. MEASUREMENTS Medication use was ascertained through a baseline inventory. Physical performance measures (timed 6-meter walk, repeated chair stands in 15 seconds) and grip strength were assessed at baseline and follow-up years 1, 3 and 6. Multivariable adjusted linear repeated- measures models adjusted for demographic and health characteristics. RESULTS ACE inhibitor use was negatively associated with mean grip strength at baseline (22.40 kg, 95% confidence interval [CI] 21.89, 22.91 versus 23.18 kg, 95% CI 23.02, 23.34; P = .005) and a greater mean annual change in number of chair stands (−.182, 95% CI −.217, −.147 versus −.145, 95% CI −.156, −.133; P = .05) compared to non-use. Statin use was not significantly associated with baseline or mean annual change for any outcome. A subgroup analysis suggested that statin use was associated with less mean annual change in chair stands (P = .006) in the oldest women. CONCLUSION These results do not support an association of statin or ACE inhibitor use with slower decline in physical performance or muscle strength, and thus do not support the use of these medications for preserving functional status in older adults. PMID:23176078

  14. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    NASA Astrophysics Data System (ADS)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  15. Effects of a vitamin D and leucine-enriched whey protein nutritional supplement on measures of sarcopenia in older adults, the PROVIDE study: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Bauer, Jürgen M; Verlaan, Sjors; Bautmans, Ivan; Brandt, Kirsten; Donini, Lorenzo M; Maggio, Marcello; McMurdo, Marion E T; Mets, Tony; Seal, Chris; Wijers, Sander L; Ceda, Gian Paolo; De Vito, Giuseppe; Donders, Gilbert; Drey, Michael; Greig, Carolyn; Holmbäck, Ulf; Narici, Marco; McPhee, Jamie; Poggiogalle, Eleonora; Power, Dermot; Scafoglieri, Aldo; Schultz, Ralf; Sieber, Cornel C; Cederholm, Tommy

    2015-09-01

    Age-related losses of muscle mass, strength, and function (sarcopenia) pose significant threats to physical performance, independence, and quality of life. Nutritional supplementation could positively influence aspects of sarcopenia and thereby prevent mobility disability. To test the hypothesis that a specific oral nutritional supplement can result in improvements in measures of sarcopenia. A multicenter, randomized, controlled, double-blind, 2 parallel-group trial among 380 sarcopenic primarily independent-living older adults with Short Physical Performance Battery (SPPB; 0-12) scores between 4 and 9, and a low skeletal muscle mass index. The active group (n = 184) received a vitamin D and leucine-enriched whey protein nutritional supplement to consume twice daily for 13 weeks. The control group (n = 196) received an iso-caloric control product to consume twice daily for 13 weeks. Primary outcomes of handgrip strength and SPPB score, and secondary outcomes of chair-stand test, gait speed, balance score, and appendicular muscle mass (by DXA) were measured at baseline, week 7, and week 13 of the intervention. Handgrip strength and SPPB improved in both groups without significant between-group differences. The active group improved more in the chair-stand test compared with the control group, between-group effect (95% confidence interval): -1.01 seconds (-1.77 to -0.19), P = .018. The active group gained more appendicular muscle mass than the control group, between-group effect: 0.17 kg (0.004-0.338), P = .045. This 13-week intervention of a vitamin D and leucine-enriched whey protein oral nutritional supplement resulted in improvements in muscle mass and lower-extremity function among sarcopenic older adults. This study shows proof-of-principle that specific nutritional supplementation alone might benefit geriatric patients, especially relevant for those who are unable to exercise. These results warrant further investigations into the role of a specific nutritional supplement as part of a multimodal approach to prevent adverse outcomes among older adults at risk for disability. Copyright © 2015 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  16. 1. CAPTIVE TEST STAND D1 FROM THE FERROCEMENT APRON, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. CAPTIVE TEST STAND D-1 FROM THE FERROCEMENT APRON, VIEW TOWARDS SOUTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-1, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  17. 2. CLOSE UP OF CAPTIVE TEST STAND D4, VIEW TOWARDS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. CLOSE UP OF CAPTIVE TEST STAND D-4, VIEW TOWARDS NORTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-4, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. 1. CAPTIVE TEST STAND D4, CONNECTING TUNNELS AT RIGHT, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. CAPTIVE TEST STAND D-4, CONNECTING TUNNELS AT RIGHT, VIEW TOWARDS NORTHEAST. - Glenn L. Martin Company, Titan Missile Test Facilities, Captive Test Stand D-4, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  19. 51. HISTORIC GENERAL VIEW LOOKING WEST AT THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. HISTORIC GENERAL VIEW LOOKING WEST AT THE TEST STAND WITH THE MERCURY REDSTONE ROCKET FULLY ASSEMBLED AND BEING PREPARED FOR TESTING. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  20. What are the Main Physical Functioning Factors Associated With Falls Among Older People With Different Perceived Fall Risk?

    PubMed

    Moreira, Mirian N; Bilton, Tereza L; Dias, Rosangela C; Ferriolli, Eduardo; Perracini, Monica R

    2017-07-01

    Fall risk perceptions may influence the judgement over physical and functional competencies to avoid falls. However, few studies have explored the physical functioning characteristics associated with falls among older people with low perceived fall risk. This study aimed to identify the prevalence of falls and physical functioning factors associated with falling among community-dwelling older adults with low and high perceived fall risk. We conducted a cross-sectional population based study with 773 community-dwelling elders. Perceived fall risk was investigated using Falls Efficacy Scale International. We considered fallers those who reported at least one fall in the previous 12 months. Physical functioning measures used were grip strength, usual gait speed, sit-to-stand test, five step test, timed up and go test, one-legged stance test, anterior and lateral functional reach test. At least one fall was reported by 103 (30%) participants with low perceived fall risk and by 196 (46%) participants with high perceived fall risk. The odds of falling were lower among those with greater grip strength and with a greater stance time in one-legged test, and the odds of falling among elders with high perceived fall risk were higher among those who took more time in performing the five step test. We believe that our results highlight the need of not neglecting the risk of falls among active older adults with low perceived fall risk, particularly in those elders that show reduced stability in a small base of support and a lower leg strength. In addition, we suggest that elders with high perceived fall risk should be assessed using anticipatory postural adjustment tests. Particularly, our results may help physiotherapists to identify eligible elders with different perceptions of fall risk for tailored interventions aimed at reducing falls. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Credit BG. Test Stand "D" tower as seen looking northeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. Test Stand "D" tower as seen looking northeast (See caption for CA-163-F-18). To the right of the view is the stainless steel dome top for Dv Cell (see CA-163-F-22 for view into cell), behind which rests a spherical accumulator--an electrically heated steam generator for powering the vacuum system at "C" and Test Stand "D." Part of the ejector system can be seen on the right corner of the tower, other connections include electrical ducts (thin, flat metal members) and fire protection systems. Note the stand in the foreground with lights used to indicate safety status of the stand during tests - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  2. Bending strength and stiffness of loblolly pine lumber from intensively managed stands located on the Georgia Lower Coastal Plain

    Treesearch

    Mark Alexander Butler; Joseph Dahlen; Richard F. Daniels; Thomas L. Eberhardt; Finto Antony

    2016-01-01

    Loblolly pine is increasingly grown on intensively managed plantation forests that yield excellent growth; however, lumber cut from these trees often contains a large percentage of juvenile wood which negatively impacts strength and stiffness. Because of changing forest management and mill practices the design values for visually graded southern pine were updated in...

  3. Haemophilia & Exercise Project (HEP): subjective and objective physical performance in adult haemophilia patients--results of a cross-sectional study.

    PubMed

    Czepa, D; Von Mackensen, S; Hilberg, T

    2012-01-01

    Recurrent musculoskeletal haemorrhages in people with haemophilia (PWH) lead to restrictions in the locomotor system and consequently in physical performance. Patients' perceptions of their health status have gained an important role in the last few years. The assessment of subjective physical performance in PWH is a new approach. This study aimed to compare the subjective physical performance of PWH with healthy controls and to correlate the results with objective data. Subjective physical performance was assessed via the new questionnaire HEP-Test-Q, which consists of 25 items pertaining to four subscales 'mobility', 'strength & coordination', 'endurance' and 'body perception'. HEP-Test-Q subscales were compared with objective data in terms of range of motion, one-leg-stand and 12-minute walk test. Forty-eight patients (44 ± 11 years) with haemophilia A (43 severe, three moderate) or B (two severe) and 43 controls without haemophilia (42 ± 11 years) were enrolled. PWH showed an impaired subjective physical performance in all HEP-Test-Q subscales and in the total score (52 ± 20) compared with controls (77 ± 10; P ≤ 0.001). Correlation analyses for the total score of the HEP-Test-Q and objective data revealed values ranging from r = 0.403 (one-leg-stand) to r = 0.757 (12-minute walk test) (P ≤ 0.001). PWH evaluated their physical performance poorer in comparison with healthy people. As self-assessment did not always correlate highly with objective data, objective examinations of physical performance in PWH should be complemented with subjective perceptions. © 2011 Blackwell Publishing Ltd.

  4. 22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. DETAIL, TWO LIGHTING TYPES AT REAR OF TEST STAND 1-A. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  5. Effects of elastic band resistance training and nutritional supplementation on physical performance of institutionalised elderly--A randomized controlled trial.

    PubMed

    Oesen, Stefan; Halper, Barbara; Hofmann, Marlene; Jandrasits, Waltraud; Franzke, Bernhard; Strasser, Eva-Maria; Graf, Alexandra; Tschan, Harald; Bachl, Norbert; Quittan, Michael; Wagner, Karl Heinz; Wessner, Barbara

    2015-12-01

    To evaluate the effects of elastic band resistance training in combination with nutrient supplementation on muscular strength and the ability to perform mobility-related activities of daily living in older adults living in retirement care facilities. Randomized controlled trial, with a 6-month intervention period. A retirement care facility, Vienna, Austria. One hundred and seventeen older adults (14 males (12%) and 103 females (88%)), aged 65 to 97 years (mean age: 82.8 ± 6.0), having a mini-mental state examination score ≥ 23 and no chronic diseases posing a medical contraindication to training therapy. Participants were randomly assigned, but stratified by sex, to one of three intervention groups: supervised resistance exercise training (RT), RT in combination with nutrient supplementation (RTS), or cognitive training group (CT). All interventions were performed two times a week for 6 months. RT was designed to train all major muscle groups using elastic bands. The nutrient supplement (rich in proteins, vitamin D, B2, B12) was distributed every morning as well as after each RT session. A battery of motor ability tests and functional test were performed prior to as well as following 3 months and finally after 6 months of intervention. These tests included isokinetic torque measurements of the knee extensors and flexors in concentric mode at 60 and 120°/s, isometric handgrip strength, senior arm-lifting test, chair stand test, maximum walking speed and a 6-minute walking test (6 MWT). A repeated-measures ANOVA analysis revealed significant improvements in physical function of lower (p=0.002) and upper extremities (p=0.006) for RT and/or RTS in comparison to CT. For isokinetic measurements, 6 MWT, and gait speed time effects (p<0.05) were detected without any group × time interaction effects. Dropouts showed lower performance in chair stand test (p=0.012), 6 MWT (p=0.003), and gait speed (p=0.013) at baseline than that of the finishers of the study. Six months of a low intensity resistance exercise using elastic bands and own body weight is safe and beneficial in improving functional performance of institutionalised older people. Multinutrient supplementation did not offer additional benefits to the effects of RT in improving muscular performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Credit BG. View looking southwest at Test Stand "D" complex. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking southwest at Test Stand "D" complex. In the background at left is the Steam Generator Plant 4280/E-81 built in 1972 to house four gas-fired Clayton flash boilers. The boilers were later supplemented by the electrically heated steam accumulator (sphere) to supply steam to the various ejectors at Test Stand "D" vacuum test cells - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  7. Intervention for the maintenance and improvement of physical function and quality of life among elderly disaster victims of the Great East Japan Earthquake and Tsunami.

    PubMed

    Greiner, Chieko; Ono, Kana; Otoguro, Chizuru; Chiba, Kyoko; Ota, Noriko

    2016-08-01

    The purpose of this study was to examine the effectiveness of an exercise class implemented in an area affected by the Great East Japan Earthquake and Tsunami for maintaining and improving physical function and quality of life (QOL) among elderly victims. Participants were 45 elderly disaster victims. To measure the effectiveness of the exercise classes, results on the Functional Reach Test (FRT), Timed Up and Go Test (TUG), One-leg Standing Balance (OSB), and Chair Stand Test (CST) were measured at the beginning of the exercise classes, and after 3 and 6months. In order to assess health-related QOL, the 8-item Short-Form Health Survey (SF-8) was carried out at the beginning of the exercise classes, and after 1, 3, and 6months. Of the 45 people who consented to participate, 27 continued the program for 6months and were used for analysis. Analysis of the results for FRT, OSB, and CST showed significant improvements (respectively, p=.000, .007, and .000). SF-8 showed significant increases for the subscales of bodily pain (p=.004), general health perception (p=.001), and mental health (p=.035). By continuing an exercise program for 6months, improvements were seen in lower limb muscle strength and balance functions. Effectiveness for HRQOL was also observed. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Influence of shift work on the physical work capacity of Tunisian nurses: a cross-sectional study in two university hospitals.

    PubMed

    Merchaoui, Irtyah; Bouzgarrou, Lamia; Mnasri, Ahlem; Mghanem, Mounir; Akrout, Mohamed; Malchaire, Jacques; Chaari, Neila

    2017-01-01

    This study has been performed to determine the influence of rotating shift work on physical working capacity of Tunisian nurses and to design recommendations to managers so that they implement effective preventive measures. It is a cross-sectional design using a standardized questionnaire and many physical capacity tests on a representative sample of 1181 nurses and nursing assistants from two university hospital centers of the school of Medicine of Monastir located in the Tunisian Sahel. 293 participants have been recruited by stratified random sampling according to gender and departments. Maximum Grip strength, 30s sit-to-stand test, one leg test, Fingertip-to-Floor test, Saltsa test and peak expiratory flow were used to assess physical capacity. Work ability was assessed through the workability index. Mental and physical loads were heavily perceived in shift healthcare workers (p=0.01; p=0.02). The maximum grip force was stronger in rotating shift work nurses (p=0.0001). Regarding to the seniority subgroups in each kind of work schedule, the Body Mass Index was increasing with seniority in both schedules. All the physical tests, were better in less-than-ten-year groups. Peak Flow and grip strength were significantly better in less-than-ten-year seniority in shift work group. There is a need to improve the design of the existing shift systems and to reduce as much as possible shift schedule as well as to avoid shift schedule for over-10-year-seniority nurses.

  9. 9. BUILDING 8769, EAST REAR AND NORTH SIDE, TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUILDING 8769, EAST REAR AND NORTH SIDE, TEST STAND AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  10. 3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. EAST SIDE, ALSO SHOWING COVERED TANKS AND TEST STAND 1-5 AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-4, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  11. Association of unipedal standing time and bone mineral density in community-dwelling Japanese women.

    PubMed

    Sakai, A; Toba, N; Takeda, M; Suzuki, M; Abe, Y; Aoyagi, K; Nakamura, T

    2009-05-01

    Bone mineral density (BMD) and physical performance of the lower extremities decrease with age. In community-dwelling Japanese women, unipedal standing time, timed up and go test, and age are associated with BMD while in women aged 70 years and over, unipedal standing time is associated with BMD. The aim of this study was to clarify whether unipedal standing time is significantly associated with BMD in community-dwelling women. The subjects were 90 community-dwelling Japanese women aged 54.7 years. BMD of the second metacarpal bone was measured by computed X-ray densitometry. We measured unipedal standing time as well as timed up and go test to assess physical performance of the lower extremities. Unipedal standing time decreased with increased age. Timed up and go test significantly correlated with age. Low BMD was significantly associated with old age, short unipedal standing time, and long timed up and go test. Stepwise regression analysis revealed that age, unipedal standing time, and timed up and go test were significant factors associated with BMD. In 21 participants aged 70 years and over, body weight and unipedal standing time, but not age, were significantly associated with BMD. BMD and physical performance of the lower extremities decrease with older age. Unipedal standing time, timed up and go test, and age are associated with BMD in community-dwelling Japanese women. In women aged 70 years and over, unipedal standing time is significantly associated with BMD.

  12. 2. Credit JPL. Photographic copy of photograph, looking northeast at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Credit JPL. Photographic copy of photograph, looking northeast at unfinished original Test Stand 'C' construction. A portion of the corrugated steel tunnel tube connecting Test Stand 'C' to the first phase of JPL tunnel system construction is visible in the foreground. The steel frame used to support propellant tanks and engine equipment has been erected. The open trap door leads to a chamber inside the Test Stand 'C' base where gaseous nitrogen is distributed via manifolds to Test Stand 'C' control valves. (JPL negative no. 384-1568-A, 19 March 1957) - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  13. Efficacy of Nintendo Wii training on mechanical leg muscle function and postural balance in community-dwelling older adults: a randomized controlled trial.

    PubMed

    Jorgensen, Martin G; Laessoe, Uffe; Hendriksen, Carsten; Nielsen, Ole Bruno Faurholt; Aagaard, Per

    2013-07-01

    Older adults show increased risk of falling and major risk factors include impaired lower extremity muscle strength and postural balance. However, the potential positive effect of biofeedback-based Nintendo Wii training on muscle strength and postural balance in older adults is unknown. This randomized controlled trial examined postural balance and muscle strength in community-dwelling older adults (75±6 years) pre- and post-10 weeks of biofeedback-based Nintendo Wii training (WII, n = 28) or daily use of ethylene vinyl acetate copolymer insoles (controls [CON], n = 30). Primary end points were maximal muscle strength (maximal voluntary contraction) and center of pressure velocity moment during bilateral static stance. Intention-to-treat analysis with adjustment for age, sex, and baseline level showed that the WII group had higher maximal voluntary contraction strength (18%) than the control group at follow up (between-group difference = 269 N, 95% CI = 122; 416, and p = .001). In contrast, the center of pressure velocity moment did not differ (1%) between WII and CON at follow-up (between-group difference = 0.23 mm(2)/s, 95% CI = -4.1; 4.6, and p = .92). For secondary end points, pre-to-post changes favoring the WII group were evident in the rate of force development (p = .03), Timed Up and Go test (p = .01), short Falls Efficacy Scale-International (p = .03), and 30-second repeated Chair Stand Test (p = .01). Finally, participants rated the Wii training highly motivating at 5 and 10 weeks into the intervention. Biofeedback-based Wii training led to marked improvements in maximal leg muscle strength (maximal voluntary contraction; rate of force development) and overall functional performance in community-dwelling older adults. Unexpectedly, static bilateral postural balance remained unaltered with Wii training. The high level of participant motivation suggests that biofeedback-based Wii exercise may ensure a high degree of compliance to home- and/or community-based training in community-dwelling older adults.

  14. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    PubMed Central

    Silva, Paula F. S.; Quintino, Ludmylla F.; Franco, Juliane; Faria, Christina D. C. M.

    2014-01-01

    Background Subjects with neurological disease (ND) usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. Objective To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. Method A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro) were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. Results Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99) for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99) for stroke and inter-rater reliability (ICC=0.99) for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77), and the feasibility and safety were good for subjects with Alzheimer's disease. Conclusions The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement properties were investigated and showed adequate results. PMID:24839043

  15. Last SSME test on A-1

    NASA Image and Video Library

    2006-09-29

    The Stennis Space Center conducted the final space shuttle main engine test on its A-1 Test Stand Friday. The A-1 Test Stand was the site of the first test on a shuttle main engine in 1975. Stennis will continue testing shuttle main engines on its A-2 Test Stand through the end of the Space Shuttle Program in 2010. The A-1 stand begins a new chapter in its operational history in October. It will be temporarily decommissioned to convert it for testing the J-2X engine, which will power the upper stage of NASA's new crew launch vehicle, the Ares I. Although this ends the stand's work on the Space Shuttle Program, it will soon be used for the rocket that will carry America's next generation human spacecraft, Orion.

  16. 45. HISTORIC AERIAL VIEW LOOKING SOUTHWEST AT THE TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. HISTORIC AERIAL VIEW LOOKING SOUTHWEST AT THE TEST STAND AND THE SURROUNDING ELECTRONICS AND EQUIPMENT TRAILERS. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  17. Probable Cause: A Decision Making Framework.

    DTIC Science & Technology

    1984-08-01

    Thus, a biochemist may see the causal link between smoking and lung cancer as due to chemical effects of tar, nicotine , and the like, on cell structure...long term and complex effects like poverty can have short term and simple causes. Determinants of Gros Strength Causal chains. While the causal...explained is a standing state. For example, what is the cause of " poverty ?" Since the effect to be explained in a standing state of large duration and

  18. The Bigger the Hand, the Bigger the Difference? Implications for Testing Strength With Two Popular Handgrip Dynamometers.

    PubMed

    Abe, Takashi; Loenneke, Jeremy P; Thiebaud, Robert S; Loftin, Mark

    2017-10-16

    Studies developed the frail elderly handgrip strength (HGS) diagnostic criteria using multiple types of handgrip dynamometers. If different handgrip dynamometer report different values, then this would have the potential to misclassify people into the wrong diagnostic category. To examine the characteristics of HGS measured by two standard handgrip dynamometers, and to investigate the influence of hand size on HGS. University research laboratory. 87 young and middle-aged adults aged 20-60 years participated in this study. Standard methods of HGS measurements were used for hydraulic and Smedley's spring-type dynamometer, although the participants were instructed to maintain an upright standing position in both tests. Test-retest reliability of hydraulic and Smedley dynamometers provided comparable results to that observed with previous studies. However, the difference in HGS between the two dynamometers (Hydraulic-Smedley difference) was positively associated (r = 0.670, p < 0.001) with the mean of the two dynamometers. The participants who had relatively low HGS (at least <35 kg) produced similar HGS values when the two dynamometers were compared, while persons who had relatively higher HGS (at least >45 kg) produced greater strength values with the hydraulic compared to the Smedley. The hand and palm lengths were weakly correlated (r = 0.349 and r = 0.358, respectively, both p < 0.001) to the difference in HGS between the two dynamometers. Test-retest reliability of hydraulic and Smedley dynamometers provides comparable results to previous studies. However, the difference in HGS between the two dynamometers was positively associated with the mean of the two dynamometers. This Hydraulic-Smedley difference would not affect persons who have relatively low HGS (at least < 35 kg), while when HGS is relatively high, the comparison between dynamometers should be done with caution.

  19. A-3 Test Stand construction moves forward

    NASA Image and Video Library

    2010-07-13

    Work on the A-3 Test Stand at Stennis Space Center took a step forward in July with delivery of the first-stage steam ejector July 13. Stennis employees are shown preparing the ejector to be lifted into place on the test stand. When activated in 2012, the A-3 Test Stand will allow operators to test rocket engines at simulated altitudes of 100,000 feet, a critical feature for next-generation engines that will take humans beyond low-Earth orbit once more.

  20. 5. BUILDING 8768, SOUTH SIDE AND EAST REAR. TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. BUILDING 8768, SOUTH SIDE AND EAST REAR. TEST STAND 1A AT LEFT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  1. 21. Building 202, underside of test stand A, detail of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Building 202, underside of test stand A, detail of junction of scrubber structure and test stand with water pipes and valves visible. View looking southeast. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH

  2. 37. HISTORIC GENERAL VIEW LOOKING WEST OF TEST STAND AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. HISTORIC GENERAL VIEW LOOKING WEST OF TEST STAND AND ROCKET DURING TEST FIRING NUMBER 2. NOTE THE FLAME BEING EMITTED FROM THE BOTTOM OF THE ROCKET. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  3. 8. VIEW LOOKING WEST AT THE POWER PLANT TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW LOOKING WEST AT THE POWER PLANT TEST STAND DURING AN ENGINE FIRING. DATE UNKNOWN, FRED ORDWAY COLLECTION, U.S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, East Test Area, Power Plant Test Stand, Huntsville, Madison County, AL

  4. Relation among 25(OH)D, Aquatic Exercises, and Multifunctional Fitness on Functional Performance of Elderly Women from the Community.

    PubMed

    Nascimento, N A Perigo; Moreira, P F P; Marin, R V; Moreira, L D F; Castro, M Lazaretti; Santos, C A F; Filho, C M A; Cendoroglo, M Seabra

    2016-04-01

    The aim of this study was to investigate if there is a relation among 25(OH)D, aquatic training, and multifunctional fitness on functional performance of elderly woman from the community. Cross-sectional study. Community. We evaluated elderly women aged ≥ 60 years (67±5 years old). One-hundred eighty were engaged in aquatic training (AT), 119 in multifunctional fitness (MF) for at least one year, and sedentary group (SED) with 162 independent elderly women from the community centers who had not practicing any regular physical exercise at least one year before. Timed up-and-go (TUG), 2-minute step test (2MST), 30-second chair stand (CS), arm curl (AC), functional reach test (FRT), unipedal balance test (UB) with visual control, handgrip right (HR) and handgrip left (HL) portable dynamometer for strength hip flexors (Hip strength) and knee extensors (Knee strength), serum 25(OH)D, intact parathyroid hormone (PTH), and creatinine clearance. Physical and functional tests showed differences among the three groups (ST; TUG, CS, AC, FR and USB = p <0.001). The PTH and the TUG test correlated inversely with 25(OH)D (r = -0.29 - p <0.001/ r = - 0.16 - p <0.001), also between 25(OH)D and BMI for AT and MF groups respectively (r= -0,15; p=0,04/ r= - 0,19; p=0,036). The AC test showed positive correlation (r = 0, 1 - p <0.001). The age and 25(OH)D were controlled and assumed to be a covariates in the statistical analysis that employed ANCOVA. There was difference on the performance of TUG test (p= 0.049). TUG performance was associated with age, exercise type and serum levels of 25(OH)D. The 25(OH)D insufficiency was common in elderly women from subtropical areas.

  5. Motor assessment using the NIH Toolbox

    PubMed Central

    Magasi, Susan; McCreath, Heather E.; Bohannon, Richard W.; Wang, Ying-Chih; Bubela, Deborah J.; Rymer, William Z.; Beaumont, Jennifer; Rine, Rose Marie; Lai, Jin-Shei; Gershon, Richard C.

    2013-01-01

    Motor function involves complex physiologic processes and requires the integration of multiple systems, including neuromuscular, musculoskeletal, and cardiopulmonary, and neural motor and sensory-perceptual systems. Motor-functional status is indicative of current physical health status, burden of disease, and long-term health outcomes, and is integrally related to daily functioning and quality of life. Given its importance to overall neurologic health and function, motor function was identified as a key domain for inclusion in the NIH Toolbox for Assessment of Neurological and Behavioral Function (NIH Toolbox). We engaged in a 3-stage developmental process to: 1) identify key subdomains and candidate measures for inclusion in the NIH Toolbox, 2) pretest candidate measures for feasibility across the age span of people aged 3 to 85 years, and 3) validate candidate measures against criterion measures in a sample of healthy individuals aged 3 to 85 years (n = 340). Based on extensive literature review and input from content experts, the 5 subdomains of dexterity, strength, balance, locomotion, and endurance were recommended for inclusion in the NIH Toolbox motor battery. Based on our validation testing, valid and reliable measures that are simultaneously low-cost and portable have been recommended to assess each subdomain, including the 9-hole peg board for dexterity, grip dynamometry for upper-extremity strength, standing balance test, 4-m walk test for gait speed, and a 2-minute walk test for endurance. PMID:23479547

  6. 10. "TEST STAND 15, AIR FORCE FLIGHT TEST CENTER." ca. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. "TEST STAND 1-5, AIR FORCE FLIGHT TEST CENTER." ca. 1958. Test Area 1-115. Original is a color print, showing Test Stand 1-5 from below, also showing the superstructure of TS1-4 at left. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Leuhman Ridge near Highways 58 & 395, Boron, Kern County, CA

  7. Stennis Space Center Conducts Water Flow Test On The B-2 Test Stand

    NASA Image and Video Library

    2018-05-04

    Stennis Space Center completed a water flow test of the refurbished B-2 Test Stand on May 4, 2018. This included both the deflector and the aspirator, individually and together. This test stand is being prepared for the testing of the Space Launch System's booster core, which will utilize four RS-25 rocket engines.

  8. SSC Test Operations Contract Overview

    NASA Technical Reports Server (NTRS)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  9. A-3 Test Stand work

    NASA Image and Video Library

    2011-07-29

    Rocket engine propellant tanks and cell dome top the A-3 Test Stand under construction at Stennis Space Center. The stand will test next-generation rocket engines that could carry humans beyond low-Earth orbit into deep space once more.

  10. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  11. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  12. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  13. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  14. 40 CFR 63.9285 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) National Emission Standards for Hazardous Air Pollutants for Engine Test Cells/Stands What This Subpart... engine test cell/stand that is located at a major source of HAP emissions. (a) An engine test cell/stand...

  15. Initial Sensorimotor and Cardiovascular Data Acquired from Soyuz Landings: Establishing a Functional Performance Recovery Time Constant

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Bloomberg, J. J.; Stenger, M. B.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; hide

    2015-01-01

    INTRODUCTION Testing of crew responses following long-duration flights has not been previously possible until a minimum of more than 24 hours after landing. As a result, it has not been possible to determine the trend of the early recovery process, nor has it been possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented joint testing at the Soyuz landing site. This International Space Station research effort has been identified as the functional Field Test, and represents data collect on NASA, Russian, European Space Agency, and Japanese Aerospace Exploration Agency crews. RESEARCH The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible on the day of landing (typically within 1 to 1.5 hours). This goal has both sensorimotor and cardiovascular elements. To date, a total of 15 subjects have participated in a 'pilot' version of the full 'field test'. The full version of the 'field test' will assess functional sensorimotor measurements included hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with the hands (both strength and ability to judge just noticeable differences of force), standing from a prone position, coordinated walking involving tandem heel-to-toe placement (tested with eyes both closed and open), walking normally while avoiding obstacles of differing heights, and determining postural ataxia while standing (measurement of quiet stance). Sensorimotor performance has been obtained using video records, and data from body worn inertial sensors. The cardiovascular portion of the investigation has measured blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during sensorimotor testing on all of the above measures. We have also collected motion sickness data associated with each of the postflight tests. When possible rudimentary cerebellar assessment was undertaken. In addition to the immediate post-landing collection of data, postflight data has been acquired twice more within 24 hours after landing and measurements continue until sensorimotor and cardiovascular responses have returned to preflight normative values (approximately 60 days postflight). SUMMARY The level of functional deficit observed in the crew tested to date is more severe than expected, clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured.

  16. Saturn Apollo Program

    NASA Image and Video Library

    1964-10-01

    Test firing of the Saturn I S-I Stage (S-1-10) at the Marshall Space Flight Center. This test stand was originally constructed in 1951 and sometimes called the Redstone or T tower. In l961, the test stand was modified to permit static firing of the S-I/S-IB stages, which produced a total thrust of 1,600,000 pounds. The name of the stand was then changed to the S-IB Static Test Stand.

  17. Use of a unipedal standing test to assess the ambulation reacquisition time during the early postoperative stage after hip fracture in elderly Japanese: prospective study.

    PubMed

    Murata, Koichi; Sugitani, Shigeki; Yoshioka, Hiroki; Noguchi, Takashi; Aoto, Toshiyuki; Nakamura, Takashi

    2010-01-01

    The aim of this study was to predict the ambulation reacquisition time after hip fracture in elderly people using the unipedal standing test during the early postoperative stage. Patients with an intertrochanteric fracture treated with internal fixation (n = 35) and patients with a femoral neck fracture treated with hemiarthroplasty (n = 22) were included. A unipedal standing test using the nonoperated leg was performed on days 3 and 7 after the operation. Among the patients with an intertrochanteric fracture, those with a positive result on the unipedal standing test on postoperative day (POD) 3 attained gait with parallel guide bars (BG) and walker-assisted gait (WG) significantly earlier than did patients with a negative result on the unipedal standing test. Patients with a positive result on the unipedal standing test on POD 7 attained BG, WG, and cane-assisted gait (CG) significantly earlier than did patients with a negative test. Among patients with a femoral neck fracture, those with a positive unipedal standing test result on POD 3 attained BG, WG, and CG significantly earlier than did patients with a negative test. Those with a positive test result on POD 7 attained BG, WG, and CG significantly earlier than did patients with a negative test. The unipedal standing test given during the early postoperative stage is a good test for predicting the ambulation reacquisition time. Moreover, it gives information that can help determine the need for subacute rehabilitation and about discharge planning and health service provision.

  18. NASA Johnson Space Center: White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Aggarwal, Pravin; Kowalski, Robert R.

    2011-01-01

    This slide presentation reviews the testing facilities and laboratories available at the White Sands Test Facility (WSTF). The mission of WSTF is to provide the expertise and infrastructure to test and evaluate spacecraft materials, components and propulsion systems that enable the safe exploration and use of space. There are nine rocket test stands in two major test areas, six altitude test stands, three ambient test stands,

  19. 17. HISTORIC VIEW OF ROCKET & LAUNCH STAND DESIGNED BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. HISTORIC VIEW OF ROCKET & LAUNCH STAND DESIGNED BY HERMANN OBERTH AND RUDOLF NEBEL FOR THE MOVIE DIE FRAU IM MOND (THE WOMAN ON THE MOON). THE LAUNCH STAND WAS MODIFIED BY THE VFR FOR THE FIRST TEST STAND AT RAKETENFLUGPLATZ NEAR BERLIN. - Marshall Space Flight Center, Redstone Rocket (Missile) Test Stand, Dodd Road, Huntsville, Madison County, AL

  20. 1. ROCKET ENGINE TEST STAND, LOCATED IN THE NORTHEAST ¼ ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ROCKET ENGINE TEST STAND, LOCATED IN THE NORTHEAST ¼ OF THE X-15 ENGINE TEST COMPLEX. Looking northeast. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  1. 3. COMPLETE X15 VEHICLE TEST STAND, LOCATED IN SOUTHEAST ¼ ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. COMPLETE X-15 VEHICLE TEST STAND, LOCATED IN SOUTHEAST ¼ OF X-15 ENGINE TEST COMPLEX. Looking northeast. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  2. CSG delivery and installation

    NASA Image and Video Library

    2010-10-27

    The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is hoisted into place at the E-2 Test Stand at John C. Stennis Space Center on Oct. 24, 2010. The unit was installed at the E-2 stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.

  3. 3. BUILDING 8767, NORTH REAR AND WEST SIDE, TEST STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. BUILDING 8767, NORTH REAR AND WEST SIDE, TEST STAND 1-A AT FAR RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  4. 5. FLAME DEFLECTOR, COMPLETE X15 VEHICLE TEST STAND. Looking east. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. FLAME DEFLECTOR, COMPLETE X-15 VEHICLE TEST STAND. Looking east. - Edwards Air Force Base, X-15 Engine Test Complex, Rocket Engine & Complete X-15 Vehicle Test Stands, Rogers Dry Lake, east of runway between North Base & South Base, Boron, Kern County, CA

  5. Menopausal status and physical performance in middle aged women: a cross-sectional community-based study in Northeast Brazil.

    PubMed

    da Câmara, Saionara M A; Zunzunegui, Maria Victoria; Pirkle, Catherine; Moreira, Mayle A; Maciel, Álvaro C C

    2015-01-01

    To examine associations between menopausal status and physical performance in middle-aged women from the Northeast region of Brazil. Cross-sectional study of women between 40 to 65 years old living in Parnamirim. Women were recruited by advertisements in primary care neighborhood centers across the city. Physical performance was assessed by grip strength, gait speed and chair stands. Menopausal status was determined using the Stages of Reproductive Aging Workshop classification and women were classified in: premenopausal, perimenopausal or postmenopausal. Multiple linear regression analyses were performed to model the effect of menopausal status on each physical performance measure, adjusting for covariates (age, family income, education, body mass index, parity and age at first birth). The premenopausal women were significantly stronger and performed better in chair stands than perimenopausal and postmenopausal women. Gait speed did not vary significantly by menopausal status. In multivariate analyses, menopausal status remained statistically significant only for grip strength. In fully adjusted analyses, premenopausal women had grip strength mean of 2.226 Kgf (95% CI: 0.361 - 4.091) higher than the postmenopausal group. This study provides further evidence for the associations between menopause and physical performance in middle-aged women, since grip strength is weaker in peri and postmenopausal women compared to premenopausal, even adjusted for age and other covariates.

  6. Should high-power posing be integrated in physical therapy?

    PubMed

    Ge, Weiqing; Bennett, Teale K; Oller, Jeremy C

    2017-04-01

    [Purpose] Postural assessment and correction is a common approach in patient management to decrease symptoms and improve function for patients. The purpose of this study was to determine the effects of high-power posing on muscle strength and pain threshold. [Subjects and Methods] Thirty-one subjects, 16 females and 15 males, mean age 28.9 (SD 10.8) years old, were recruited through a convenience sampling on the university campus. The research design was a randomized controlled trial. In the experimental group, the subjects were instructed to stand in a high-power posture. In the control group, the subjects were instructed to stand in a low-power posture. Grip strength and pain threshold measurements were conducted before and after the postural intervention. [Results] The grip strength changed by -3.4 (-3.7, 0.3) % and 1.7 (-3.6, 5.3) % for the experimental and control groups, respectively. The pain threshold changed by 0.6 (-9.9, 10.4) % and 15.1 (-9.3, 24.4) % for the experimental and control groups, respectively. However, both changes were not significant as all the 95% CIs included 0. [Conclusions] The data did not show significant benefits of high-power posing in increasing grip strength and pain threshold compared to low-power posing.

  7. Should high-power posing be integrated in physical therapy?

    PubMed Central

    Ge, Weiqing; Bennett, Teale K.; Oller, Jeremy C.

    2017-01-01

    [Purpose] Postural assessment and correction is a common approach in patient management to decrease symptoms and improve function for patients. The purpose of this study was to determine the effects of high-power posing on muscle strength and pain threshold. [Subjects and Methods] Thirty-one subjects, 16 females and 15 males, mean age 28.9 (SD 10.8) years old, were recruited through a convenience sampling on the university campus. The research design was a randomized controlled trial. In the experimental group, the subjects were instructed to stand in a high-power posture. In the control group, the subjects were instructed to stand in a low-power posture. Grip strength and pain threshold measurements were conducted before and after the postural intervention. [Results] The grip strength changed by −3.4 (−3.7, 0.3) % and 1.7 (−3.6, 5.3) % for the experimental and control groups, respectively. The pain threshold changed by 0.6 (−9.9, 10.4) % and 15.1 (−9.3, 24.4) % for the experimental and control groups, respectively. However, both changes were not significant as all the 95% CIs included 0. [Conclusions] The data did not show significant benefits of high-power posing in increasing grip strength and pain threshold compared to low-power posing. PMID:28533612

  8. Individual differences in chess expertise: a psychometric investigation.

    PubMed

    Grabner, Roland H; Stern, Elsbeth; Neubauer, Aljoscha C

    2007-03-01

    Starting from controversies over the role of general individual characteristics (especially intelligence) for the attainment of expert performance levels, a comprehensive psychometric investigation of individual differences in chess expertise is presented. A sample of 90 adult tournament chess players of varying playing strengths (1311-2387 ELO) was screened with tests on intelligence and personality variables; in addition, experience in chess play, tournament participation, and practice activities were assessed. Correlation and regression analyses revealed a clear-cut moderate relationship between general (and in particular numerical) intelligence and the participants' playing strengths, suggesting that expert chess play does not stand in isolation from superior mental abilities. The strongest predictor of the attained expertise level, however, was the participants' chess experience which highlights the relevance of long-term engagement for the development of expertise. Among all analysed personality dimensions, only domain-specific performance motivation and emotion expression control incrementally contributed to the prediction of playing strength. In total, measures of chess experience, current tournament activity, intelligence, and personality accounted for about 55% of variance in chess expertise. The present results suggest that individual differences in chess expertise are multifaceted and cannot be reduced to differences in domain experience.

  9. A best practice fall prevention exercise program to improve balance, strength / power, and psychosocial health in older adults: study protocol for a randomized controlled trial

    PubMed Central

    2013-01-01

    Background With increasing age neuromuscular deficits (e.g., sarcopenia) may result in impaired physical performance and an increased risk for falls. Prominent intrinsic fall-risk factors are age-related decreases in balance and strength / power performance as well as cognitive decline. Additional studies are needed to develop specifically tailored exercise programs for older adults that can easily be implemented into clinical practice. Thus, the objective of the present trial is to assess the effects of a fall prevention program that was developed by an interdisciplinary expert panel on measures of balance, strength / power, body composition, cognition, psychosocial well-being, and falls self-efficacy in healthy older adults. Additionally, the time-related effects of detraining are tested. Methods/Design Healthy old people (n = 54) between the age of 65 to 80 years will participate in this trial. The testing protocol comprises tests for the assessment of static / dynamic steady-state balance (i.e., Sharpened Romberg Test, instrumented gait analysis), proactive balance (i.e., Functional Reach Test; Timed Up and Go Test), reactive balance (i.e., perturbation test during bipedal stance; Push and Release Test), strength (i.e., hand grip strength test; Chair Stand Test), and power (i.e., Stair Climb Power Test; countermovement jump). Further, body composition will be analysed using a bioelectrical impedance analysis system. In addition, questionnaires for the assessment of psychosocial (i.e., World Health Organisation Quality of Life Assessment-Bref), cognitive (i.e., Mini Mental State Examination), and fall risk determinants (i.e., Fall Efficacy Scale – International) will be included in the study protocol. Participants will be randomized into two intervention groups or the control / waiting group. After baseline measures, participants in the intervention groups will conduct a 12-week balance and strength / power exercise intervention 3 times per week, with each training session lasting 30 min. (actual training time). One intervention group will complete an extensive supervised training program, while the other intervention group will complete a short version ('3 times 3’) that is home-based and controlled by weekly phone calls. Post-tests will be conducted right after the intervention period. Additionally, detraining effects will be measured 12 weeks after program cessation. The control group / waiting group will not participate in any specific intervention during the experimental period, but will receive the extensive supervised program after the experimental period. Discussion It is expected that particularly the supervised combination of balance and strength / power training will improve performance in variables of balance, strength / power, body composition, cognitive function, psychosocial well-being, and falls self-efficacy of older adults. In addition, information regarding fall risk assessment, dose–response-relations, detraining effects, and supervision of training will be provided. Further, training-induced health-relevant changes, such as improved performance in activities of daily living, cognitive function, and quality of life, as well as a reduced risk for falls may help to lower costs in the health care system. Finally, practitioners, therapists, and instructors will be provided with a scientifically evaluated feasible, safe, and easy-to-administer exercise program for fall prevention. Trial registration ClinicalTrials.gov Identifier: NCT01906034 PMID:24106864

  10. Credit WCT. Photographic copy of photograph, view looking south down ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view looking south down easternmost tunnel axis during second phase of JPL tunnel construction in 1959. Reinforced concrete formwork for Test Stand "D" foundation appears in left foreground. Formwork for Building 4222/E-23 (Test Stand "D" Workshop) is in place in right foreground with disturbed earth for western leg of tunnel system evident in background. Test Stand "C" is in center background, where first phase of tunnel construction ended. Test Stand "A" appears as tower in right background. (JPL negative no. 384-1838-C, 9 March 1959) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  11. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey.

    PubMed

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Cross-sectional study. Twenty-three female ice hockey players aged 15-25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Regression models (adj R (2)) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time-consuming laboratory assessments if the purpose is to gain knowledge about key performance characteristics of skating.

  12. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey

    PubMed Central

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    Objectives The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Design Cross-sectional study. Methods Twenty-three female ice hockey players aged 15–25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Results Regression models (adj R2) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Conclusion Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time-consuming laboratory assessments if the purpose is to gain knowledge about key performance characteristics of skating. PMID:27574474

  13. 10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. OBSERVATION POST NO. 3, WEST OF TEST STAND 1-A. SOUTH SIDE AND EAST FRONT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunkers for Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. Detail of north side of Test Stand 'A' base, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of north side of Test Stand 'A' base, showing tanks for distilled water (left), fuel (center), and gaseous nitrogen (right). Other tanks present for tests were removed before this image was taken. - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA

  15. 6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. Looking south from north wall of terminal room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  16. 7. ROCKET SLED ON DECK OF TEST STAND 15. Photo ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. ROCKET SLED ON DECK OF TEST STAND 1-5. Photo no. "6085, G-EAFB-16 SEP 52." Looking south to machine shop. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-5, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  17. Balance and muscle power of children with Charcot-Marie-Tooth.

    PubMed

    Silva, Tais R; Testa, Amanda; Baptista, Cyntia R J A; Marques, Wilson; Mattiello-Sverzut, Ana C

    2014-01-01

    In certain diseases, functional constraints establish a greater relationship with muscle power than muscle strength. However, in hereditary peripheral polyneuropathies, no such relationship was found in the literature. In children with Charcot-Marie-Tooth (CMT), to identify the impact of muscle strength and range of movement on the static/dynamic balance and standing long jump based on quantitative and functional variables. The study analyzed 19 participants aged between 6 and 16 years, of both genders and with clinical diagnoses of CMT of different subtypes. Anthropometric data, muscle strength of the lower limbs (hand-held dynamometer), ankle and knee range of movement, balance (Pediatric Balance Scale) and standing long jump distance were obtained by standardized procedures. For the statistical analysis, Pearson and Spearman correlation coefficients were used. There was a strong positive correlation between balance and the muscle strength of the right plantar flexors (r=0.61) and dorsiflexors (r=0.59) and a moderate correlation between balance and the muscle strength of inversion (r=0.41) and eversion of the right foot (r=0.44). For the long jump and range of movement, there was a weak positive correlation with right and left plantar flexion (r=0.20 and r=0.12, respectively) and left popliteal angle (r=0.25), and a poor negative correlation with left dorsiflexion (r=-0.15). The data on the patients analyzed suggests that the maintenance of distal muscle strength favors performance during balance tasks, while limitations in the range of movement of the legs seem not to be enough to influence the performance of the horizontal long jump.

  18. KEITH HIGGINBOTHAM AT TEST STAND 4699

    NASA Image and Video Library

    2016-10-17

    KEITH HIGGINBOTHAM, STRUCTURAL TEST LEAD FOR THE SLS SPACECRAFT PAYLOAD INTEGRATION AND EVOLUTION OFFICE, IS SHOWN BESIDE TEST STAND 4699 AT THE MARSHALL SPACE FLIGHT CENTER’S WEST TEST AREA. HIGGINBOTHAM WILL BE LEADING STRUCTURAL LOADS TESTING AT TEST STAND 4699 FOR THE CORE STAGE SIMULATER AND THE LAUNCH VEHICLE STAGE ADAPTER. THE TEST SERIES WILL ENSURE EACH STRUCTURE CAN WITHSTAND THE INCREDIBLE STRESSES OF LAUNCH.

  19. Case report: a balance training program using the Nintendo Wii Fit to reduce fall risk in an older adult with bilateral peripheral neuropathy.

    PubMed

    Hakim, Renée Marie; Salvo, Charles J; Balent, Anthony; Keyasko, Michael; McGlynn, Deidre

    2015-02-01

    A recent systematic review supported the use of strength and balance training for older adults at risk for falls, and provided preliminary evidence for those with peripheral neuropathy (PN). However, the role of gaming systems in fall risk reduction was not explored. The purpose of this case report was to describe the use of the Nintendo® Wii™ Fit gaming system to train standing balance in a community-dwelling older adult with PN and a history of recurrent near falls. A 76-year-old patient with bilateral PN participated in 1 h of Nintendo® Wii™ Fit balance training, two times a week for 6 weeks. Examination was conducted using a Computerized Dynamic Posturography system (i.e. Sensory Organization Test (SOT), Limits of Stability (LOS), Adaptation Test (ADT) and Motor Control Test (MCT) and clinical testing with the Berg Balance Scale (BBS), Timed Up and Go (TUG), Activities-specific Balance Confidence (ABC) scale and 30-s Chair Stand. Following training, sensory integration scores on the SOT were unchanged. Maximum excursion abilities improved by a range of 37-86% on the LOS test. MCT scores improved for amplitude with forward translations and ADT scores improved for downward platform rotations. Clinical scores improved on the BBS (28/56-34/56), ABC (57.5-70.6%) and TUG (14.9-10.9 s) which indicated reduced fall risk. Balance training with a gaming system showed promise as a feasible, objective and enjoyable method to improve physical performance and reduce fall risk in an individual with PN.

  20. METAL MEDIA FILTERS, AG-1 SECTION FI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamson, D.

    One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures,more » media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.« less

Top