Sample records for strip test based

  1. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  2. Fluorimetric Mercury Test Strips with Suppressed "Coffee Stains" by a Bio-inspired Fabrication Strategy.

    PubMed

    Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua

    2016-11-04

    A fluorimetric Hg 2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the "coffee stains" toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized "coffee stains". On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg 2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of "coffee stains" on test strips may expand the scope of applications of test strips-based "point-of-care" analysis methods or detection devices in the biomedical and environmental fields.

  3. Fluorimetric Mercury Test Strips with Suppressed “Coffee Stains” by a Bio-inspired Fabrication Strategy

    PubMed Central

    Qiao, Yuchun; Shang, Jizhen; Li, Shuying; Feng, Luping; Jiang, Yao; Duan, Zhiqiang; Lv, Xiaoxia; Zhang, Chunxian; Yao, Tiantian; Dong, Zhichao; Zhang, Yu; Wang, Hua

    2016-01-01

    A fluorimetric Hg2+ test strip has been developed using a lotus-inspired fabrication method for suppressing the “coffee stains” toward the uniform distribution of probe materials through creating a hydrophobic drying pattern for fast solvent evaporation. The test strips were first loaded with the model probes of fluorescent gold-silver nanoclusters and then dried in vacuum on the hydrophobic pattern. On the one hand, here, the hydrophobic constraining forces from the lotus surface-like pattern could control the exterior transport of dispersed nanoclusters on strips leading to the minimized “coffee stains”. On the other hand, the vacuum-aided fast solvent evaporation could boost the interior Marangoni flow of probe materials on strips to expect the further improved probe distribution on strips. High aqueous stability and enhanced fluorescence of probes on test strips were realized by the hydrophilic treatment with amine-derivatized silicane. A test strips-based fluorimetry has thereby been developed for probing Hg2+ ions in wastewater, showing the detection performances comparable to the classic instrumental analysis ones. Such a facile and efficient fabrication route for the bio-inspired suppression of “coffee stains” on test strips may expand the scope of applications of test strips-based “point-of-care” analysis methods or detection devices in the biomedical and environmental fields. PMID:27812040

  4. Sensitive albuminuria analysis using dye-binding based test strips.

    PubMed

    Delanghe, Joris R; Himpe, Jonas; De Cock, Naomi; Delanghe, Sigurd; De Herde, Kevin; Stove, Veronique; Speeckaert, Marijn M

    2017-08-01

    Populations at increased risk for chronic kidney disease should be screened for albuminuria. Possibilities of advanced urine strip readers based on complementary metal oxide semiconductor (CMOS) sensor technology were investigated for obtaining quantitative albuminuria results. Reflectance data of test strips (Sysmex UFC 3500 reader+CMOS) were compared with albuminuria (BNII) and with proteinuria (Cobas 8000). Urinary creatinine was assayed using a Jaffe-based creatinine assay (Cobas 8000). Calibration curve was made between 11.5 and 121.5mg/L with detection limit of 5.5mg/L. Within-run CV values of reflectance data were 0.21% (UC-Control L; 10mg/L) and 0.37% (UC-Control H; >150mg/L) for albumin, and 0.71%/3.97% for creatinine. Between-run CV values were 0.24%/0.42% for albumin and 0.93%/5.13% for creatinine. A strong correlation (r=0.92) was obtained between albuminuria (BNII) and protein strip reflectance data. Creatinine reflectance data correlated well with Jaffe-based urinary creatinine data (r=0.90). Albumin:creatinine ratio obtained by test strip and by wet chemistry showed a good correlation (r=0.59). Carbamylated, glycated and partially hydrolyzed isoforms of albumin could be detected by test strip. Dye-binding based albumin test strip assay in combination with a CMOS based reader would potentially allow quantitative analysis of albuminuria and determination of albumin:creatinine ratio. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    NASA Astrophysics Data System (ADS)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c

  6. A colloidal gold nanoparticle-based immunochromatographic test strip for rapid and convenient detection of Staphylococcus aureus.

    PubMed

    Niu, Kaili; Zheng, Xiaoping; Huang, Chusen; Xul, Kuan; Zhi, Yuan; Shen, Hebai; Jia, Nengqin

    2014-07-01

    An immunochromatographic test strip using gold nanoparticles-staphylococcus aureus monoclonal antibody conjugates was developed for the rapid and convenient detection of staphylococcus aureus based on a double-antibody sandwich format. The detection limit and the detection rate of this test strip is 10(3) CFU /mL and 98.7%, respectively. It could be used for the rapid detection of staphylococcus aureus in food and the results can be visually identified by the naked eye within 10 min. Compared with conventional bacterial detection methods, this developed immunochromatographic assay based test strip has several advantages including simple, fast, low-cost, favorable sensitivity and specificity, exhibiting a great potential for application in food safety control systems and clinical diagnosis.

  7. Smartphone-based analysis of biochemical tests for health monitoring support at home.

    PubMed

    Velikova, Marina; Smeets, Ruben L; van Scheltinga, Josien Terwisscha; Lucas, Peter J F; Spaanderman, Marc

    2014-09-01

    In the context of home-based healthcare monitoring systems, it is desirable that the results obtained from biochemical tests - tests of various body fluids such as blood and urine - are objective and automatically generated to reduce the number of man-made errors. The authors present the StripTest reader - an innovative smartphone-based interpreter of biochemical tests based on paper-based strip colour using image processing techniques. The working principles of the reader include image acquisition of the colour strip pads using the camera phone, analysing the images within the phone and comparing them with reference colours provided by the manufacturer to obtain the test result. The detection of kidney damage was used as a scenario to illustrate the application of, and test, the StripTest reader. An extensive evaluation using laboratory and human urine samples demonstrates the reader's accuracy and precision of detection, indicating the successful development of a cheap, mobile and smart reader for home-monitoring of kidney functioning, which can facilitate the early detection of health problems and a timely treatment intervention.

  8. Papers Based Electrochemical Biosensors: From Test Strips to Paper-Based Microfluidics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bingwen; Du, Dan; Hua, Xin

    2014-05-08

    Papers based biosensors such as lateral flow test strips and paper-based microfluidic devices (or paperfluidics) are inexpensive, rapid, flexible, and easy-to-use analytical tools. An apparent trend in their detection is to interpret sensing results from qualitative assessment to quantitative determination. Electrochemical detection plays an important role in quantification. This review focuses on electrochemical (EC) detection enabled biosensors. The first part provides detailed examples in paper test strips. The second part gives an overview of paperfluidics engaging EC detections. The outlook and recommendation of future directions of EC enabled biosensors are discussed in the end.

  9. Development and comparison of immunochromatographic strips with three nanomaterial labels: Colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon for visual detection of salbutamol.

    PubMed

    Liu, Bing; Wang, Lingling; Tong, Bei; Zhang, Yan; Sheng, Wei; Pan, Mingfei; Wang, Shuo

    2016-11-15

    In this study, the three nanomaterials: colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon were respectively labeled with the antibody against salbutamol (SAL). We aimed to develop immunochromatographic strips with these nanomaterial labels and determine their performance in visual detection of SAL. For the colloidal gold-based strip, the detection limit of SAL was 1.0µgL(-1) in standard solution and 5.0µgkg(-1) in meat samples. For the GPG- and colloidal carbon-based strips, the limit of detection was 2.0µgL(-1) in standard solution and 10µgkg(-1) in meat samples. The results obtained using the test strips were found to be highly consistent with those obtained using a commercial kit, indicating the high accuracy of these strips. The three strips were also found to be stable up to 18 weeks under laboratory conditions. In terms of sensitivity, the colloidal gold-based strip was slightly better than the other two. For the GPG- and colloidal carbon-based strips, the difference between the results obtained for different batches was small (high consistency), and the stability was much better than that of the colloidal gold-based one. Our results indicate that colloidal carbon can be used as a label in immunochromatographic tests; it can also help reduce the cost involved and scale-up the production. The use of immunochromatographic test strips labeled with colloidal carbon can be a rapid and inexpensive method for SAL assays in on-site applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Smartphone-Based Point-of-Care Urinalysis Under Variable Illumination

    PubMed Central

    Ra, Moonsoo; Lim, Chiawei; Han, Sehui; Jung, Chansung; Kim, Whoi-Yul

    2018-01-01

    Urine tests are performed by using an off-the-shelf reference sheet to compare the color of test strips. However, the tabular representation is difficult to use and more prone to visual errors, especially when the reference color-swatches to be compared are spatially apart. Thus, making it is difficult to distinguish between the subtle differences of shades on the reagent pads. This manuscript represents a new arrangement of reference arrays for urine test strips (urinalysis). Reference color swatches are grouped in a doughnut chart, surrounding each reagent pad on the strip. The urine test can be evaluated using naked eye by referring to the strip with no additional sheet necessary. Along with this new strip, an algorithm for smartphone based application is also proposed as an alternative to deliver diagnostic results. The proposed colorimetric detection method evaluates the captured image of the strip, under various color spaces and evaluates ten different tests for urine. Thus, the proposed system can deliver results on the spot using both naked eye and smartphone. The proposed scheme delivered accurate results under various environmental illumination conditions without any calibration requirements, exhibiting performances suitable for real-life applications and an ease for a common user. PMID:29333352

  11. Anion-intercalated layered double hydroxides modified test strips for detection of heavy metal ions.

    PubMed

    Wang, Nan; Sun, Jianchao; Fan, Hai; Ai, Shiyun

    2016-01-01

    In this work, a novel approach for facile and rapid detection of heavy metal ions using anion-intercalated layered double hydroxides (LDHs) modified test strips is demonstrated. By intercalating Fe(CN)6(4-) or S(2-) anions into the interlayers of LDHs on the filter paper, various heavy metal ions can be easily detected based on the color change before and after reaction between the anions and the heavy metal ions. Upon the dropping of heavy metal ions solutions to the test strips, the colors of the test strips changed instantly, which can be easily observed by naked eyes. With the decrease of the concentration, the color depth changed obviously. The lowest detection concentration can be up to 1×10(-6) mol L(-1). Due to the easily intercalation of anions into the interlayer of the LDHs on test trips, this procedure provides a general method for the construction of LDHs modified test strips for detection of heavy metal ions. The stability of the prepared test strips is investigated. Furthermore, all the results were highly reproducible. The test strips may have potential applications in environmental monitoring fields. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Nanoscale Test Strips for Multiplexed Blood Analysis

    NASA Technical Reports Server (NTRS)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  13. Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhaohui; Wang, Ying; Wang, Jun

    2010-08-15

    A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescencemore » intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.« less

  14. "Taste Strips" - a rapid, lateralized, gustatory bedside identification test based on impregnated filter papers.

    PubMed

    Landis, Basile Nicolas; Welge-Luessen, Antje; Brämerson, Annika; Bende, Mats; Mueller, Christian Albert; Nordin, Steven; Hummel, Thomas

    2009-02-01

    To elaborate normative values for a clinical psychophysical taste test ("Taste Strips"). The "Taste Strips" are a psychophysical chemical taste test. So far, no definitive normative data had been published and only a fairly small sample size has been investigated. In light of this shortcoming for this easy, reliable and quick taste testing device, we attempted to provide normative values suitable for the clinical use. Normative value acquisition study, multicenter study. The investigation involved 537 participants reporting a normal sense of smell and taste (318 female, 219 male, mean age 44 years, age range 18-87 years). The taste test was based on spoon-shaped filter paper strips ("Taste Strips") impregnated with the four (sweet, sour, salty, and bitter) taste qualities in four different concentrations. The strips were placed on the left or right side of the anterior third of the extended tongue, resulting in a total of 32 trials. With their tongue still extended, patients had to identify the taste from a list of four descriptors, i. e., sweet, sour, salty, and bitter (multiple forced-choice). To obtain an impression of overall gustatory function, the number of correctly identified tastes was summed up for a "taste score". Taste function decreased significantly with age. Women exhibited significantly higher taste scores than men which was true for all age groups. The taste score at the 10(th) percentile was selected as a cut-off value to distinguish normogeusia from hypogeusia. Results from a small series of patients with ageusia confirmed the clinical usefulness of the proposed normative values. The present data provide normative values for the "Taste Strips" based on over 500 subjects tested.

  15. Micro-strip sensors based on CVD diamond

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2000-10-01

    In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.

  16. Development of a colloidal gold immunochromatographic strip based on HSP70 for the rapid detection of Echinococcus granulosus in sheep.

    PubMed

    Zhuo, Xunhui; Yu, Yingchao; Chen, Xueqiu; Zhang, Zhuangzhi; Yang, Yi; Du, Aifang

    2017-06-15

    Echinococcus granulosus is the causative pathogen of cystic echinococcosis, a serious disease endangering human and animal health. In this study, an immunochromatographic strip was developed based on the recombinant protein Heat shock protein 70 (HSP70) for the serological detection of E. granulosus. The protocol completes within 20min requiring no specialized equipment or chemical reagents, while specificity tests confirmed no cross-reactivity with positive serum of Fasciola hepatica, Haemonchus contortus, Peste des petits ruminants virus (PPRV) and Foot-and-mouth disease virus (FMDV). The strips remained stable after storage at 4°C for up to 8 months. Both immunochromatographic strip and ELISA tests were applied to detect E. granulosus antibody in a total of 728 serum samples obtained from slaughter houses in Zhejiang Province. Our data revealed positive rates of 2.61 and 1.65% by immunochromatographic strip and ELISA methods, respectively. The immunochromatographic strip test developed in this study provides a simple, specific and rapid method of E. granulosus antibody detection and infected sheep monitoring. Copyright © 2017. Published by Elsevier B.V.

  17. Ultrasensitive Immunochromatographic Strip for Fast Screening of 27 Sulfonamides in Honey and Pork Liver Samples Based on a Monoclonal Antibody.

    PubMed

    Chen, Yanni; Guo, Lingling; Liu, Liqiang; Song, Shanshan; Kuang, Hua; Xu, Chuanlai

    2017-09-20

    Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC 50 ) values ranging from 0.15 to 15.38 μg/L. In particular, the IC 50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 μg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 μg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.

  18. Colorimetric analysis of saliva–alcohol test strips by smartphone-based instruments using machine-learning algorithms

    USDA-ARS?s Scientific Manuscript database

    Strip lateral flow assays, similar to a home pregnancy test, are used widely in food safety applications to provide rapid and accurate tests for the presence of specific foodborne pathogens or other contaminants. Though these tests are very rapid, they are not very sensitive, are not quantitative, a...

  19. Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips

    NASA Astrophysics Data System (ADS)

    Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang

    2016-02-01

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.

  20. Smartphone-Based Dual-Modality Imaging System for Quantitative Detection of Color or Fluorescent Lateral Flow Immunochromatographic Strips

    NASA Astrophysics Data System (ADS)

    Hou, Yafei; Wang, Kan; Xiao, Kun; Qin, Weijian; Lu, Wenting; Tao, Wei; Cui, Daxiang

    2017-04-01

    Nowadays, lateral flow immunochromatographic assays are increasingly popular as a diagnostic tool for point-of-care (POC) test based on their simplicity, specificity, and sensitivity. Hence, quantitative detection and pluralistic popular application are urgently needed in medical examination. In this study, a smartphone-based dual-modality imaging system was developed for quantitative detection of color or fluorescent lateral flow test strips, which can be operated anywhere at any time. In this system, the white and ultra-violet (UV) light of optical device was designed, which was tunable with different strips, and the Sobel operator algorithm was used in the software, which could enhance the identification ability to recognize the test area from the background boundary information. Moreover, this technology based on extraction of the components from RGB format (red, green, and blue) of color strips or only red format of the fluorescent strips can obviously improve the high-signal intensity and sensitivity. Fifty samples were used to evaluate the accuracy of this system, and the ideal detection limit was calculated separately from detection of human chorionic gonadotropin (HCG) and carcinoembryonic antigen (CEA). The results indicated that smartphone-controlled dual-modality imaging system could provide various POC diagnoses, which becomes a potential technology for developing the next-generation of portable system in the near future.

  1. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

    PubMed

    Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S

    2017-12-19

    In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.

  2. Detection system for concentration quantization of colloidal-gold test strips based on embedded and image technology

    USDA-ARS?s Scientific Manuscript database

    Facing the increasing food safety issues, Chinese government has been carrying out compulsory tests on food to meet the requirements of domestic and foreign markets. Colloidal-gold test strips using the colorimetric principle are widely used for rapid qualitative detection of harmful residues in fo...

  3. Self-Monitoring of Blood Glucose Levels: Evaluating the Impact of a Policy of Quantity Limits on Test-Strip Use and Costs.

    PubMed

    Gomes, Tara; Martins, Diana; Tadrous, Mina; Paterson, J Michael; Shah, Baiju R; Juurlink, David N; Singh, Samantha; Mamdani, Muhammad M

    2016-10-01

    To evaluate the impact of new quantity limits for blood glucose test strips (BGTS) in August 2013 on utilization patterns and costs in the elderly population of Ontario, Canada. We conducted a population-based, cross-sectional time series analysis of all individuals 65 years of age and older who received publically funded BGTSs between August 1, 2010, and July 31, 2015, in Ontario, Canada. The number of BGTSs dispensed and the associated costs were measured for 4 diabetes therapy subgroups-insulin, hypoglycemia-inducing oral agents, non-hypoglycemia-inducing oral agents, and no drug therapy-each month during the study period. We used interventional autoregressive integrated moving average (ARIMA) models to assess the impact of Ontario's policy change on test strip use and costs. In the course of the study period, 657,338,177 test strips were dispensed to elderly patients in Ontario, at a total cost of CAN$482.3 million. Introduction of quantity limits was associated with significant reductions in the number of monthly strips dispensed and the associated costs (p<0.0001). In the year following the policy's implementation, test strip use decreased by 22.2% compared with the prior year (from 145,232,024 test strips to 113,007,795 test strips, a net decrease of 32,224,229 strips), resulting in a 22.5% reduction in costs (from $106.5 million to $82.6 million, a net cost reduction of approximately $24 million). The introduction of quantity limits, aligned with guidance from the Canadian Diabetes Association, led to immediate significant reductions in BGTS dispensing and costs. More research is needed to assess the impact of this policy on patient outcomes. Copyright © 2016 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  4. Nanocolloidal gold-based immuno-dip strip assay for rapid detection of Sudan red I in food samples.

    PubMed

    Wang, Jia; Wang, Zhanhui; Liu, Jing; Li, Hao; Li, Qing X; Li, Ji; Xu, Ting

    2013-02-15

    A semiquantitative dip strip assay was developed using nanocolloidal gold-labelled monoclonal antibody (Mab) 8A10 for the rapid detection of Sudan red I in food samples. A protein-Sudan red I conjugate was coated on a nitro cellulose membrane strip in a defined test line. In flow of the complex of nanocolloidal gold labelled-Mab and Sudan red I along the strip, intensive red colour that was formed in the test line reflected the Sudan red I concentration. The test required 10 min and had a visual limit of detection of 10 ng/g Sudan red I in tomato sauce and chilli powder samples. The results of the strip assay agreed well with those of a high performance liquid chromatography method for both spiked and real commercial samples. The strip was stable for at least 2 months at 4°C. The strip assay offers the potential as a useful rapid and simple method for screening of Sudan red I in food samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Development of a Combined Human Transferrin-Hemoglobin Lateral Immunochromatographic Assay for Accurate and Rapid Fecal Occult Blood Test.

    PubMed

    Ye, Yuanyuan; Deng, Yin; Mao, Jinju; Yan, Qin; Huang, Yidan; Zhang, Jun; Zheng, Jian; Li, Yue; Chen, Weixian

    2018-05-01

    Fecal occult bloodtest (FOBT) plays an important role in the diagnosis of gastrointestinal diseases. The sensitivities of current FOBT methods are still not satisfactory. The aim of this study is to develop a combined human transferrin (HTf)-hemoglobin (HHb) lateral flow assay (LFA) for accurate and rapid FOBT. Monoclonal antibodies (MAbs) targeting HTf were developed by conventional methods and paired using LFA strips. The best HTf MAb pair was chosen according to the overall performance on testing limit and specificity. Meanwhile, HHb LFA strips were prepared using previously developed HHb MAbs. The testing limit and specificity were characterized. Based on the selected HTf MAb pair and the verified HHb MAb pair, combined HTf-HHb strips were developed. The combined HTf-HHb strips were used for FOBT of 400 human fecal samples, including 200 gastrointestinal bleeding specimens and 200 healthy subjects. For comparison, the homemade individual HTf and HHb strips, as well as three kinds of commercial FOBT strips, were also used for the FOBT. Two MAb pairs targeting HTf were developed for LFA. Two types of HTf strips were prepared accordingly. The type I was chosen due to its lower detection limit. Using the type I HTf MAb pair and the verified HHb- MAb pair, the combined HTf-HHb strips could detect the HTf at concentrations between 1 ng/mL and 1 x 106 ng/mL and the HHb between 10 ng/mL and 2.5 x 106 ng/mL. Compared to individual HTf and HHb strips and three kinds of commercial strips, the combined strips showed the highest diagnostic sensitivity in FOBT (96.0%). The specificity was a satisfactory 99%. Our combined HTf-HHb test strips are a very promising product for accurate and rapid FOBT.

  6. Detection of Bacteria Using Inkjet-Printed Enzymatic Test Strips

    PubMed Central

    2015-01-01

    Low-cost diagnostics for drinking water contamination have the potential to save millions of lives. We report a method that uses inkjet printing to copattern an enzyme–nanoparticle sensor and substrate on a paper-based test strip for rapid detection of bacteria. A colorimetric response is generated on the paper substrate that allows visual detection of contamination without the need for expensive instrumentation. These strips demonstrate a viable nanomanufacturing strategy for low-cost bacterial detection. PMID:25318086

  7. Nitrogen-doped graphene quantum dots-based fluorescence molecularly imprinted sensor for thiacloprid detection.

    PubMed

    Liu, Yang; Cao, Nan; Gui, Wenying; Ma, Qiang

    2018-06-01

    In this paper, a test strip-based sensor was developed for thiacloprid quantitative detection based on PDA molecularly imprinted polymer (MIP) and nitrogen-doped graphene quantum dots (N-GQDs). Thiacloprid is a new type of nicotine insecticide, which can block the normal neurotransmitter delivery process in insects. In the sensing system, N-GQDs were immersed into filter paper at first. Then, dopamine (DA) with thiacloprid can be self-polymerized on test strip surface to form the uniform PDA film. After removed thiacloprid template, the established poly dopamine (PDA) MIP can selectively recognize thiacloprid. As a result, captured thiacloprid can enhance the fluorescence intensity of N-GQDs into the test strip. As a result, the fluorescence intensity of N-GQDs can be linearly related within a certain range of thiacloprid concentration. Under the optimum conditions, the proposed sensor for thiacloprid detection exhibited a linear ranging from 0.1 mg/L to 10 mg/L with a low detection limit of 0.03 mg/L. The N-GQDs based test strip-based sensor for thiaclopridis reported for the first time. The sensing system has high selectivity to thiacloprid and provides new opportunities in the pesticide detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Colloidal gold-McAb probe-based rapid immunoassay strip for simultaneous detection of fumonisins in maize.

    PubMed

    Yao, Jingjing; Sun, Yaning; Li, Qingmei; Wang, Fangyu; Teng, Man; Yang, Yanyan; Deng, Ruiguang; Hu, Xiaofei

    2017-05-01

    Fumonisins are a kind of toxic and carcinogenic mycotoxin. A rapid immunochromatographic test strip has been developed for simultaneous detection of fumonisin B 1 , B 2 and B 3 (FB 1 , FB 2 and FB 3 ) in maize based on colloidal gold-labelled monoclonal antibody (McAb) against FB 1 probe. The anti-FB 1 McAb (2E11-H3) was produced through immunisation and cell fusion, and identified as high affinity, specificity and sensitivity. The cross-reaction ratios with fumonisin B 2 and B 3 were accordingly 385% and 72.4%, while none with other analogues. The colloid gold-labelled anti-FB 1 McAb probe was successfully prepared and used for establishing the immunochromatographic strip. The test strip showed high sensitivity and specificity, the IC 50 for FB 1 was 58.08 ng mL -1 , LOD was 11.24 ng mL -1 , calculated from standard curve. Moreover, the test strip exhibited high cross-reactivity with FB 2 and FB 3 , and could be applied to the simultaneous detection of FBs (FB 1 :FB 2 :FB 3 = 12:4:1) in maize sample with high accuracy and precision. The average recoveries of FBs in maize ranged from 90.42% to 95.29%, and CVs were 1.25-3.77%. The results of the test strip for FBs samples showed good correlation with high-performance liquid chromatography analysis. The immunochromatographic test strip could be employed in the rapid simultaneous detection of FB 1 , FB 2 and FB 3 in maize samples on-site. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  9. A CCD-based reader combined with CdS quantum dot-labeled lateral flow strips for ultrasensitive quantitative detection of CagA

    NASA Astrophysics Data System (ADS)

    Gui, Chen; Wang, Kan; Li, Chao; Dai, Xuan; Cui, Daxiang

    2014-02-01

    Immunochromatographic assays are widely used to detect many analytes. CagA is proved to be associated closely with initiation of gastric carcinoma. Here, we reported that a charge-coupled device (CCD)-based test strip reader combined with CdS quantum dot-labeled lateral flow strips for quantitative detection of CagA was developed, which used 365-nm ultraviolet LED as the excitation light source, and captured the test strip images through an acquisition module. Then, the captured image was transferred to the computer and was processed by a software system. A revised weighted threshold histogram equalization (WTHE) image processing algorithm was applied to analyze the result. CdS quantum dot-labeled lateral flow strips for detection of CagA were prepared. One hundred sera samples from clinical patients with gastric cancer and healthy people were prepared for detection, which demonstrated that the device could realize rapid, stable, and point-of-care detection, with a sensitivity of 20 pg/mL.

  10. Development of an immunochromatographic strip test for rapid detection of melamine in raw milk, milk products, and animal feed

    USDA-ARS?s Scientific Manuscript database

    A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 µg/mL in raw milk, since the detection test line ...

  11. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized bymore » quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.« less

  12. Development of a one-step immunochromatographic strip test using gold nanoparticles for the rapid detection of Salmonella typhi in human serum.

    PubMed

    Preechakasedkit, Pattarachaya; Pinwattana, Kulwadee; Dungchai, Wijitar; Siangproh, Weena; Chaicumpa, Wanpen; Tongtawe, Pongsri; Chailapakul, Orawon

    2012-01-15

    An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi O901 and antibody of S. typhi O901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi O901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14×10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88×10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. A Low-Cost Inkjet-Printed Glucose Test Strip System for Resource-Poor Settings.

    PubMed

    Gainey Wilson, Kayla; Ovington, Patrick; Dean, Delphine

    2015-06-12

    The prevalence of diabetes is increasing in low-resource settings; however, accessing glucose monitoring is extremely difficult and expensive in these regions. Work is being done to address the multitude of issues surrounding diabetes care in low-resource settings, but an affordable glucose monitoring solution has yet to be presented. An inkjet-printed test strip solution is being proposed as a solution to this problem. The use of a standard inkjet printer is being proposed as a manufacturing method for low-cost glucose monitoring test strips. The printer cartridges are filled with enzyme and dye solutions that are printed onto filter paper. The result is a colorimetric strip that turns a blue/green color in the presence of blood glucose. Using a light-based spectroscopic reading, the strips show a linear color change with an R(2) = .99 using glucose standards and an R(2) = .93 with bovine blood. Initial testing with bovine blood indicates that the strip accuracy is comparable to the International Organization for Standardization (ISO) standard 15197 for glucose testing in the 0-350 mg/dL range. However, further testing with human blood will be required to confirm this. A visible color gradient was observed with both the glucose standard and bovine blood experiment, which could be used as a visual indicator in cases where an electronic glucose meter was unavailable. These results indicate that an inkjet-printed filter paper test strip is a feasible method for monitoring blood glucose levels. The use of inkjet printers would allow for local manufacturing to increase supply in remote regions. This system has the potential to address the dire need for glucose monitoring in low-resource settings. © 2015 Diabetes Technology Society.

  14. An ultra-sensitive monoclonal antibody-based fluorescent microsphere immunochromatographic test strip assay for detecting aflatoxin M1 in milk

    USDA-ARS?s Scientific Manuscript database

    A rapid lateral flow fluorescent microspheres immunochromatography test strip (FMs-ICTS) has been developed for the detection of aflatoxin M1 (AFM1) residues in milk. For this purpose, an ultra-sensitive anti-AFM1 monoclonal antibody (MAb) 1D3 was prepared and identified. The IC50 value of the MA...

  15. Review of Adverse Events Associated With False Glucose Readings Measured by GDH-PQQ–Based Glucose Test Strips in the Presence of Interfering Sugars

    PubMed Central

    Frias, Juan P.; Lim, Christine G.; Ellison, John M.; Montandon, Carol M.

    2010-01-01

    OBJECTIVE To assess the implications of falsely elevated glucose readings measured with glucose dehydrogenase pyrroloquinolinequinone (GDH-PQQ) test strips. RESEARCH DESIGN AND METHODS We conducted a review of the Food and Drug Administration's Manufacturer and User Facility Device Experience database and medical literature for adverse events (AEs) associated with falsely elevated glucose readings with GDH-PQQ test strips in the presence of interfering sugars. RESULTS Eighty-two reports were identified: 16 (20%) were associated with death, 46 (56%) with severe hypoglycemia, and 12 (15%) with nonsevere hypoglycemia. In eight reports (10%), the AE was not described. Forty-two events (51%) occurred in the U.S. Although most events occurred in hospitalized patients, at least 14 (17%) occurred in outpatients. Agents most commonly associated with AEs were icodextrin-containing peritoneal dialysate and maltose-containing intravenous immune globulin. CONCLUSIONS GDH-PQQ test strips pose a safety risk to insulin-using patients treated with agents containing or metabolized to interfering sugars. PMID:20351227

  16. Comparsion of an immunochromatographic strip with ELISA for simultaneous detection of thiamphenicol, florfenicol and chloramphenicol in food samples.

    PubMed

    Guo, Lingling; Song, Shanshan; Liu, Liqiang; Peng, Juan; Kuang, Hua; Xu, Chuanlai

    2015-09-01

    Rapid and sensitive indirect competitive enzyme-linked immunosorbent assays (ic-ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D-threo-1-(4-aminophenyl)-2- dichloroacetylamino-1,3-propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic-ELISA was established. The quantitative working range for TAP was 0.11-1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross-reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic-ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic-ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  18. 360-degrees profilometry using strip-light projection coupled to Fourier phase-demodulation.

    PubMed

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-11

    360 degrees (360°) digitalization of three dimensional (3D) solids using a projected light-strip is a well-established technique in academic and commercial profilometers. These profilometers project a light-strip over the digitizing solid while the solid is rotated a full revolution or 360-degrees. Then, a computer program typically extracts the centroid of this light-strip, and by triangulation one obtains the shape of the solid. Here instead of using intensity-based light-strip centroid estimation, we propose to use Fourier phase-demodulation for 360° solid digitalization. The advantage of Fourier demodulation over strip-centroid estimation is that the accuracy of phase-demodulation linearly-increases with the fringe density, while in strip-light the centroid-estimation errors are independent. Here we proposed first to construct a carrier-frequency fringe-pattern by closely adding the individual light-strip images recorded while the solid is being rotated. Next, this high-density fringe-pattern is phase-demodulated using the standard Fourier technique. To test the feasibility of this Fourier demodulation approach, we have digitized two solids with increasing topographic complexity: a Rubik's cube and a plastic model of a human-skull. According to our results, phase demodulation based on the Fourier technique is less noisy than triangulation based on centroid light-strip estimation. Moreover, Fourier demodulation also provides the amplitude of the analytic signal which is a valuable information for the visualization of surface details.

  19. Magnetoelastic Effect-Based Transmissive Stress Detection for Steel Strips: Theory and Experiment

    PubMed Central

    Zhang, Qingdong; Su, Yuanxiao; Zhang, Liyuan; Bi, Jia; Luo, Jiang

    2016-01-01

    For the deficiencies of traditional stress detection methods for steel strips in industrial production, this paper proposes a non-contact stress detection scheme based on the magnetoelastic effect. The theoretical model of the transmission-type stress detection is established, in which the output voltage and the tested stress obey a linear relation. Then, a stress detection device is built for the experiment, and Q235 steel under uniaxial tension is tested as an example. The result shows that the output voltage rises linearly with the increase of the tensile stress, consistent with the theoretical prediction. To ensure the accuracy of the stress detection method in actual application, the temperature compensation, magnetic shielding and some other key technologies are investigated to reduce the interference of the external factors, such as environment temperature and surrounding magnetic field. The present research develops the theoretical and experimental foundations for the magnetic stress detection system, which can be used for online non-contact monitoring of strip flatness-related stress (tension distribution or longitudinal residual stress) in the steel strip rolling process, the quality evaluation of strip flatness after rolling, the life and safety assessment of metal construction and other industrial production links. PMID:27589742

  20. Laboratory and Field Evaluation of a New Rapid Test for Detecting Wuchereria bancrofti Antigen in Human Blood

    PubMed Central

    Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.

    2013-01-01

    Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552

  1. Development of Lateral Flow Immunochromatographic Strips for Micropollutant Screening Using Colorants of Aptamer-Functionalized Nanogold Particles, Part II: Experimental Verification with Aflatoxin B1 and Chloramphenicol.

    PubMed

    Zhang, Shan; Zhao, Shuai; Wang, Sai; Liu, Jiahui; Dong, Yiyang

    2018-05-09

    Lateral flow immunochromatographic strips based on colorants of aptamer-functionalized nanogold particles weredeveloped for the detection of micropollutants aflatoxin B1 (AFB1) and chloramphenicol (CAP). The lateral flow immunochromatographic strip was based on a competitive reaction of thiolated-aptamer between micropollutants and bio-DNA probe-streptavidin as capture material immobilized at the test line. General crucial parameters that might influence the sensitivity have been systematically investigated. To test the effectiveness and applicability of the optimized conditions, two structurally unrelated micropollutants, that is, AFB1 and CAP, were chosen for detection. In the present study, lateral flow immunochromatographic strips for AFB1 and CAP analysis by combining the high selectivity and affinity of aptamers with the unique optical properties of nanogold in municipal water samples were reported for the first time. With the optimized conditions, the immunochromatographic strip showed a visual LOD of 10 ppb and a quantitative LOD of 1.05 ppb using an immunochromatographic reader for AFB1 detection and a quantitative LOD of 63.4 ppb using an immunochromatographic reader for CAP detection. Furthermore, the sensitive strip provided a good linear detection range of approximately 0-50 ppm for AFB1 detection and a wider liner detection range of approximately 0-160 ppm for CAP detection. Moreover, the immunochromatographic strip provided recovery rates for water samples of 90-110% in the AFB1 analysis and 84-108% in the CAP analysis. The results demonstrated that the immunochromatographic strip has excellent potential for wide applicability and verified that the strip methods for the optimized conditions are applicable to a variety of micropollutants. The lateral flow immunochromatographic strip could be used as a simple, rapid, and efficient screening tool for rapid on-site detection of a variety of micropollutants.

  2. A Rapid and Sensitive Strip-Based Quick Test for Nerve Agents Tabun, Sarin, and Soman Using BODIPY-Modified Silica Materials.

    PubMed

    Climent, Estela; Biyikal, Mustafa; Gawlitza, Kornelia; Dropa, Tomáš; Urban, Martin; Costero, Ana M; Martínez-Máñez, Ramón; Rurack, Knut

    2016-08-01

    Test strips that in combination with a portable fluorescence reader or digital camera can rapidly and selectively detect chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB), and Soman (GD) and their simulants in the gas phase have been developed. The strips contain spots of a hybrid indicator material consisting of a fluorescent BODIPY indicator covalently anchored into the channels of mesoporous SBA silica microparticles. The fluorescence quenching response allows the sensitive detection of CWAs in the μg m(-3) range in a few seconds. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. AgBufferBuilder: A geographic information system (GIS) tool for precision design and performance assessment of filter strips

    Treesearch

    M. G. Dosskey; S. Neelakantan; T. G. Mueller; T. Kellerman; M. J. Helmers; E. Rienzi

    2015-01-01

    Spatially nonuniform runoif reduces the water qua1iry perfortnance of constant- width filter strips. A geographic inlormation system (Gls)-based tool was developed and tested that ernploys terrain analysis to account lor spatially nonuniform runoffand produce more ellbctive filter strip designs.The computer program,AgBufTerBuilder, runs with ATcGIS versions 10.0 and 10...

  4. Efficient TEA CO II-laser-based coating removal system

    NASA Astrophysics Data System (ADS)

    Prinsloo, F. J.; van Heerden, S. P.; Ronander, E.; Botha, L. R.

    2007-05-01

    A high power 1kW pulsed transversely excited atmospheric CO II laser that has been developed for the paint stripping of missiles was used to test paint stripping on several metallic and composite aircraft panels to determine the rate at which this laser could remove paint from aircraft.

  5. Effect of pH Test-Strip Characteristics on Accuracy of Readings.

    PubMed

    Metheny, Norma A; Gunn, Emily M; Rubbelke, Cynthia S; Quillen, Terrilynn Fox; Ezekiel, Uthayashanker R; Meert, Kathleen L

    2017-06-01

    Little is known about characteristics of colorimetric pH test strips that are most likely to be associated with accurate interpretations in clinical situations. To compare the accuracy of 4 pH test strips with varying characteristics (ie, multiple vs single colorimetric squares per calibration, and differing calibration units [1.0 vs 0.5]). A convenience sample of 100 upper-level nursing students with normal color vision was recruited to evaluate the accuracy of the test strips. Six buffer solutions (pH range, 3.0 to 6.0) were used during the testing procedure. Each of the 100 participants performed 20 pH tests in random order, providing a total of 2000 readings. The sensitivity and specificity of each test strip was computed. In addition, the degree to which the test strips under- or overestimated the pH values was analyzed using descriptive statistics. Our criterion for correct readings was an exact match with the pH buffer solution being evaluated. Although none of the test strips evaluated in our study was 100% accurate at all of the measured pH values, those with multiple squares per pH calibration were clearly superior overall to those with a single test square. Test strips with multiple squares per calibration were associated with greater overall accuracy than test strips with a single square per calibration. However, because variable degrees of error were observed in all of the test strips, use of a pH meter is recommended when precise readings are crucial. ©2017 American Association of Critical-Care Nurses.

  6. Screws, Propellers and Fans Based on a Mobius Strip

    NASA Technical Reports Server (NTRS)

    Seiner, John M.; Backley, Floyd D.; Gilinsky, Mikhail

    1998-01-01

    A Mobius strip concept is intended for improving the working efficiency of propellers and screws. Applications involve cooling, boat propellers, mixing in appliance, blenders, and helicopters. Several Mobius shaped screws for the average size kitchen mixers have been made and tested. The tests have shown that the mixer with the Mobius shaped screw pair is most efficient, and saves more than 30% of the electric power by comparison with the standard. The created video film about these tests illustrates efficiency of Mobius shaped screws.

  7. Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Fang; Wang, Kaihua; Lin, Yuehe

    2005-10-10

    A novel, sensitive immunochromatographic electrochemical biosensor (IEB) which combines an immunochromatographic strip technique with an electrochemical detection technique is demonstrated. The IEB takes advantages of the speed and low-cost of the conventional immunochromatographic test kits and high-sensitivity of stripping voltammetry. Bismuth ions (Bi3+) have been coupled with the antibody through the bifunctional chelating agent diethylenetriamine pentaacetic acid (DTPA). After immunoreactions, Bi3+ was released and quantified by anodic stripping voltammetry at a built-in single-use screen-printed electrode. As an example for the applications of such novel device, the detection of human chorionic gonadotronphin (HCG) in a specimen was performed. This biosensor providesmore » a more user-friendly, rapid, clinically accurate, and less expensive immunoassay for such analysis in specimens than currently available test kits.« less

  8. Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.

    PubMed

    Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2004-01-01

    An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.

  9. Urchin-like gold nanoparticle-based immunochromatographic strip test for rapid detection of fumonisin B1 in grains.

    PubMed

    Ren, Wenjie; Huang, Zhibing; Xu, Yang; Li, Yanping; Ji, Yanwei; Su, Baowei

    2015-09-01

    An immunochromatographic strip (ICS) using urchin-like gold nanoparticles (UGNs) for sensitive detection of fumonisin B1 (FB1) was developed to meet the requirement for rapidly monitoring FB1 in grain samples. The sensitivity of the ICS was 5.0 ng/mL, which represents a fourfold increase in sensitivity over conventional strip preparation using colloidal gold as the antibody-labeled probe. Analysis of FB1 in grain samples showed that data obtained from the strip tests were in a good agreement with those obtained from HPLC and enzyme-linked immunosorbent assays (ELISAs). This qualitative test did not require any specialized equipment, and the detection time was less than 5 min, which is suitable for on-site testing of FB1 in grain samples. Overall, to our knowledge, this is the first report of using a UGN as the antibody-labeled probe for sensitive detection of FB1 in grains using an ICS. Graphical Abstract Preparation of ICS using conventional colloidal gold and urchin-like gold nanoparticle, respectively.

  10. Polyhydric polymer-functionalized fluorescent probe with enhanced aqueous solubility and specific ion recognition: A test strips-based fluorimetric strategy for the rapid and visual detection of Fe3+ ions.

    PubMed

    Duan, Zhiqiang; Zhang, Chunxian; Qiao, Yuchun; Liu, Fengjuan; Wang, Deyan; Wu, Mengfan; Wang, Ke; Lv, Xiaoxia; Kong, Xiangmu; Wang, Hua

    2017-08-01

    A polyhydric polymer-functionalized probe with enhanced aqueous solubility was designed initially by coupling 1-pyrenecarboxyaldehyde (Pyr) onto poly(vinyl alcohol) (PVA) via the one-step condensation reaction. Polyhydric PVA polymer chains could facilitate the Pyr fluorophore with largely improved aqueous solubility and especially strong cyan fluorescence. Importantly, the fluorescence of the PVA-Pyr probes could thereby be quenched specifically by Fe 3+ ions through the strong PVA-Fe 3+ interaction triggering the polymeric probe aggregation. Furthermore, a test strips-based fluorimetric method was developed with the stable and uniform probe distribution by taking advantage of the unique film-forming ability and the depression capacity of "coffee-stain" effects of PVA matrix. The as-developed test strips could allow for the rapid and visual detections of Fe 3+ ions simply by a dipping way, showing a linear concentration range of 5.00-300μM, with the detection limit of 0.73μM. Moreover, the proposed method was applied to the evaluation of Fe 3+ ions in natural water samples, showing the analysis performances better or comparable to those of current detection techniques. This test strips-based fluorimetric strategy promises the extensive applications for the rapid on-site monitoring of Fe 3+ ions in environmental water and the outdoor finding of the potential iron mines. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Multistix 10 SG Leukocyte Esterage Dipstick Testing in Rapid Bedside Diagnosis of Spontaneous Bacterial Peritonitis: A Prospective Study.

    PubMed

    Jha, Ashish K; Kumawat, Dal C; Bolya, Yasvant K; Goenka, Mahesh K

    2012-09-01

    Spontaneous bacterial peritonitis (SBP) requires rapid diagnosis and the initiation of antibiotics. Diagnosis of SBP is usually based on cytobacteriological examination of ascitic fluid. These tests require good laboratory facilities and reporting time of few hours to 1-2 day. However, the 24 h laboratory facilities not widely available in country like India. We evaluated the diagnostic utility of reagent strip (Multistix 10 SG(®)) for rapid diagnosis of SBP. The study was prospectively carried out on patients of cirrhosis with ascites. Bedside leukocyte esterase reagent strip testing was performed on ascitic fluid. Cell count as determined by colorimetric scale of reagent strip was compared with counting chamber method. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Out of 100 patients with cirrhotic ascites, [72 males: 28 female; mean age 44.34 (SD 13.03) years] 18 patients were diagnosed to have SBP by counting chamber method as compared to 14 patients detected to have SBP by reagent strip test ≥++ positive. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of reagent strip ≥++ positive were 77.77%, 95.12%, 77.77%, 95.12% and 92% respectively compared to counting chamber method. Reagent strip to diagnose SBP is very specific but less sensitive as compared to counting chamber method. This can be performed rapidly, easily and efficiently even in remote area of developing countries. This bedside test could be a useful tool for the diagnosis of SBP in country like India.

  12. Intensity of regionally applied tastes in relation to administration method: an investigation based on the "taste strips" test.

    PubMed

    Manzi, Brian; Hummel, Thomas

    2014-02-01

    To compare various methods to apply regional taste stimuli to the tongue. "Taste strips" are a clinical tool to determine gustatory function. How a patient perceives the chemical environment in the mouth is a result of many factors such as taste bud distribution and interactions between the cranial nerves. To date, there have been few studies describing the different approaches to administer taste strips to maximize taste identification accuracy and intensity. This is a normative value acquisition pilot and single-center study. The investigation involved 30 participants reporting a normal sense of smell and taste (18 women, 12 men, mean age 33 years). The taste test was based on spoon-shaped filter paper strips impregnated with four taste qualities (sweet, sour, salty, and bitter) at concentrations shown to be easily detectable by young healthy subjects. The strips were administered in three methods (held stationary on the tip of the tongue, applied across the tongue, held in the mouth), resulting in a total of 12 trials per participant. Subjects identified the taste from a list of four descriptors, (sweet, sour, salty, bitter) and ranked the intensity on a scale from 0 to 10. Statistical analyses were performed on the accuracy of taste identification and rated intensities. The participants perceived in order of most to least intense: salt, sour, bitter, sweet. Of the four tastes, sour consistently was least accurately identified. Presenting the taste strip inside the closed mouth of the participants produced the least accurate taste identification, whereas moving the taste strip across the tongue led to a significant increase in intensity for the sweet taste. In this study of 30 subjects at the second concentration, optimized accuracy and intensity of taste identification was observed through administration of taste strips laterally across the anterior third of the extended tongue. Further studies are required on more subjects and the additional concentrations prior to determining the ideal taste strip application method.

  13. Competitive immunochromatographic assay for the detection of the organophosphorus pesticide chlorpyrifos

    PubMed Central

    Kim, Young Ah; Lee, Eun-Hye; Kim, Kwang-Ok; Lee, Yong Tae; Hammock, Bruce D.; Lee, Hye-Sung

    2014-01-01

    An immunochromatographic assay (ICA) based on competitive antigen-coated format using colloidal gold as the label was developed for the detection of the organophosphorus insecticide chlorpyrifos. The ICA test strip consisted of a membrane with a detection zone, a sample pad and an absorbent pad. The membrane was separately coated with chlorpyrifos hapten-OVA conjugate (test line) and anti-mouse IgG (control line). Based on the fact that the competition is between the migrating analyte in the sample and the analyte hapten immobilized on the test strip for the binding sites of the antibody-colloidal gold (Ab-CG) conjugate migrating on the test strip, this study suggests that the relative migration speed between the two migrating substances is a critically important factor for the sensitive detection by competitive ICA. This criterion was utilized for the confirmation of appropriateness of a nitrocellulose (NC) membrane for chlorpyrifos ICA. The detection limit of the ICA for chlorpyrifos standard and chlorpyrifos spiked into agricultural samples were 10 and 50 ng mL−1, respectively. The assay time for the ICA test was less than 10 min, suitable for rapid on-site testing of chlorpyrifos. PMID:21504817

  14. Development and evaluation of a gold nanoparticle-based immunochromatographic strip test for the detection of canine parvovirus.

    PubMed

    Sharma, Chhavi; Singh, Mithilesh; Upmanyu, Vikramaditya; Chander, Vishal; Verma, Suman; Chakrovarty, Soumendu; Sharma, Gaurav K; Dhanze, Himani; Singh, Praveen; Shrivastava, Sameer; Kumar, Jyoti; Goswami, Tapas Kumar; Gupta, V K

    2018-05-08

    Canine parvovirus (CPV) is the leading viral cause of enteritis in dogs and occurs mainly in 6- to 8-week-old pups. Rapid diagnosis of CPV under field conditions is now possible due to commercially available immunochromatographic (IC) assays. However, these commercial kits are somewhat expensive because they utilize a minimum of two monoclonal antibodies (mAbs) targeting different epitopes as capture and detector antibodies. Using only a single mAb for both capture and detection purpose may reduce the sensitivity of the assay. In the present study, efforts were made to develop an economical assay that can be utilized for diagnosis of CPV under Indian conditions with a high level of confidence. Rabbit polyclonal antibodies (pAbs) generated against recombinant truncated VP2 proteins of CPV were used as capture antibodies because they can be produced economically, while a commercial anti-CPV mAb was used as the detector antibody. The detection limit of the test strip was 6.6×10 5 TCID 50 /ml, and it specifically detected CPV-2, CPV-2a and CPV-2b while displaying no cross-reactivity with other common canine enteric pathogens. The relative sensitivity/specificity of pAb based strip test was 71%/92% and 71%/100% in relation to the hemagglutination test and a commercial IC kit, respectively, with substantial agreement. In addition, two commercially available mAbs targeting different epitopes were also used for development of another IC assay, which showed sensitivity, and specificity of 82%/87% and 90%/98% in relation to the hemagglutination test and commercial kit. Hence, the present strip test based on a combination of mAb and pAb provides an acceptable alternative for onsite and cost-effective diagnosis of CPV infection.

  15. Comparing reliabilities of strip and conventional patch testing.

    PubMed

    Dickel, Heinrich; Geier, Johannes; Kreft, Burkhard; Pfützner, Wolfgang; Kuss, Oliver

    2017-06-01

    The standardized protocol for performing the strip patch test has proven to be valid, but evidence on its reliability is still missing. To estimate the parallel-test reliability of the strip patch test as compared with the conventional patch test. In this multicentre, prospective, randomized, investigator-blinded reliability study, 132 subjects were enrolled. Simultaneous duplicate strip and conventional patch tests were performed with the Finn Chambers ® on Scanpor ® tape test system and the patch test preparations nickel sulfate 5% pet., potassium dichromate 0.5% pet., and lanolin alcohol 30% pet. Reliability was estimated by the use of Cohen's kappa coefficient. Parallel-test reliability values of the three standard patch test preparations turned out to be acceptable, with slight advantages for the strip patch test. The differences in reliability were 9% (95%CI: -8% to 26%) for nickel sulfate and 23% (95%CI: -16% to 63%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test method for the detection of allergic contact sensitization in patients with suspected allergic contact dermatitis is reliable. Its application in routine clinical practice can be recommended, especially if the conventional patch test result is presumably false negative. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Hard X-ray Detector Calibrations for the FOXSI Sounding Rocket

    NASA Astrophysics Data System (ADS)

    Lopez, A.; Glesener, L.; Buitrago Casas, J. C.; Han, R.; Ishikawa, S. N.; Christe, S.; Krucker, S.

    2015-12-01

    In the study of high-energy solar flares, detailed X-ray images and spectra of the Sun are required. The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment is used to test direct-focusing X-ray telescopes and Double-sided Silicon Strip Detectors (DSSD) for solar flare study and to further understand coronal heating. The measurement of active region differential emission measures, flare temperatures, and possible quiet-Sun emission requires a precisely calibrated spectral response. This poster describes recent updates in the calibration of FOXSI's DSSDs based on new calibration tests that were performed after the second flight. The gain for each strip was recalculated using additional radioactive sources. Additionally, the varying strip sensitivity across the detectors was investigated and based on these measurements, the flight images were flatfielded. These improvements lead to more precise X-ray data for future FOXSI flights and show promise for these new technologies in imaging the Sun.

  17. Thermodynamic Behavior Research Analysis of Twin-roll Casting Lead Alloy Strip Process

    NASA Astrophysics Data System (ADS)

    Jiang, Chengcan; Rui, Yannian

    2017-03-01

    The thermodynamic behavior of twin-roll casting (TRC) lead alloy strip process directly affects the forming of the lead strip, the quality of the lead strip and the production efficiency. However, there is little research on the thermodynamics of lead alloy strip at home and abroad. The TRC lead process is studied in four parameters: the pouring temperature of molten lead, the depth of molten pool, the roll casting speed, and the rolling thickness of continuous casting. Firstly, the thermodynamic model for TRC lead process is built. Secondly, the thermodynamic behavior of the TRC process is simulated with the use of Fluent. Through the thermodynamics research and analysis, the process parameters of cast rolling lead strip can be obtained: the pouring temperature of molten lead: 360-400 °C, the depth of molten pool: 250-300 mm, the roll casting speed: 2.5-3 m/min, the rolling thickness: 8-9 mm. Based on the above process parameters, the optimal parameters(the pouring temperature of molten lead: 375-390 °C, the depth of molten pool: 285-300 mm, the roll casting speed: 2.75-3 m/min, the rolling thickness: 8.5-9 mm) can be gained with the use of the orthogonal experiment. Finally, the engineering test of TRC lead alloy strip is carried out and the test proves the thermodynamic model is scientific, necessary and correct. In this paper, a detailed study on the thermodynamic behavior of lead alloy strip is carried out and the process parameters of lead strip forming are obtained through the research, which provide an effective theoretical guide for TRC lead alloy strip process.

  18. Quantifiable Lateral Flow Assay Test Strips

    NASA Technical Reports Server (NTRS)

    2003-01-01

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  19. Immunochromatographic Strip Assay for Detection of Cronobacter sakazakii in Pure Culture.

    PubMed

    Song, Xinjie; Shukla, Shruti; Lee, Gibaek; Kim, Myunghee

    2016-11-28

    Cronobacter sakazakii ( C. sakazakii ) is a foodborne pathogen, posing a high risk of disease to infants and immunocompromised individuals. In order to develop a quick, easy, and sensitive assay for detecting C. sakazakii , a rabbit anti- C. sakazakii immunoglobulin G (IgG) was developed using sonicated cell protein from C. sakazakii . The developed anti- C. sakazakii (IgG) was of good quality and purity, as well as species-specific. The developed rabbit anti- C. sakazakii IgG was attached to the surface of a sulforhodamine B-encapsulated liposome to form an immunoliposome. A test strip was then prepared by coating goat anti-rabbit IgG onto the control line and rabbit anti- C. sakazakii IgG onto the test line, respectively, of a plastic-backed nitrocellulose membrane. A purple color signal both on the test line and the control line indicated the presence of C. sakazakii in the sample, whereas purple color only on the control line indicated the absence of C. sakazakii in the sample. This immunochromatographic strip assay could produce results in 15 min with a limit of detection of 10 7 CFU/ml in C. sakazakii culture. The immunochromatographic strip assay also showed very good specificity without cross-reactivity with other tested Cronobacter species. Based on these results, the developed immunochromatographic strip assay is efficient for the detection of C. sakazakii and has high potential for on-site detection.

  20. Buffer strips in composites at elevated temperature

    NASA Technical Reports Server (NTRS)

    Bigelow, C. A.

    1983-01-01

    The composite material 'buffer strip' concept is presently investigated at elevated temperatures for the case of graphite/polyimide buffer strip panels using a (45/0/45/90)2S layup, where the buffer strip material was 0-deg S-glass/polyimide. Each panel was loaded in tension until it failed, and radiographs and crack opening displacements were recorded during the tests to determine fracture onset, fracture arrest, and the extent of damage in the buffer strip after crack arrest. At 177 + or - 3 C, the buffer strips increased the panel strength by at least 40 percent in comparison with panels without buffer strips. Compared to similar panels tested at room temperature, those tested at elevated temperature had lower residual strengths, but higher failure strains.

  1. Test strips based on iron(iii)-impregnated alginate/polyacrylonitrile nanofibers for naked eye screening of tetracycline.

    PubMed

    Li, Yan; Mohammed, Abedalwafa; Li, De; Wang, Lu

    2018-05-03

    Tetracycline (TC) is an inexpensive broad-spectrum antibiotic used to treat infectious diseases and to promote growth in animals. However, driven by economic interest, abuse of TC poses a serious threat to human beings, and it remains a significant challenge to create easy-to-use TC colorimetric test strips for public use. Herein, we present a strategy to prepare free-standing, nanofibrous structured test strips with tortuous porous structure and large surface area by combining polyacrylonitrile nanofibrous membranes (PAN NMs), alginate, and Fe3+. In this approach, alginate was first functionalized on the PAN NMs and then, Fe3+ was assembled into the alginate to construct a TC-sensing surface. The resultant test strips exhibited the following integrated properties: fast sensing process (10 min), low naked eye detection limit (5 μg kg-1), excellent anti-interference ability, and satisfactory reusability. Furthermore, the TC concentration-dependent color change (yellow to maroon) was quantitatively visualized by an iPhone read-out hue parameter. All the findings indicate that this intriguing approach may pave the way for versatile designing of NMs to serve as a preventive treatment for the public.

  2. Laboratory testing of Alcoscan saliva-alcohol test strips

    DOT National Transportation Integrated Search

    1986-10-01

    This report describes a laboratory evaluation of Alcoscan saliva-alcohol test strips. The objectives of this work were: (1) to determine the precision and accuracy of the Alcoscan strips; and (2) to determine what effect extreme ambient temperatures ...

  3. Diagnostic Value of Leukocyte Esterase Test Strip Reagents for Rapid Clinical Diagnosis of Spontaneous Bacterial Peritonitis in Patients Admitted to Hospital Emergency Departments in Iran.

    PubMed

    Hashemian, Amir Masoud; Ahmadi, Koorosh; Zamani Moghaddam, Hamid; Zakeri, Hosein; Davoodi Navakh, Seyed Akbar; Sharifi, Mohammad Davood; Bahrami, Abdollah

    2015-10-01

    Spontaneous bacterial peritonitis (SBP) is a common and important clinical problem and is life-threatening in decompensated liver disease. Ascites fluid test by leukocyte esterase test strip has been recently proposed as an effective and rapid method to diagnose SBP in patients with cirrhosis. This study aimed to evaluate sensitivity and specificity of leukocyte esterase test strip in the diagnosis of SBP. The population of this research was all patients with cirrhosis and ascites admitted to the emergency room at Imam Reza (AS) hospital, Mashhad. A written consent was taken for inclusion in the study. 50 mL ascites sample was taken from all patients for use in a urine test strip (LER) (Urine Test Strips Convergys®Urine Matrix 11). The patient's ascites samples were evaluated for cell counting. Positive dipstick test for LER in this study considered as grade 3 +. The values of WBC > 500 cell/mm(3) or PMN > 250 cell/mm(3) considered as positive result of the gold standard method for the diagnosis of SBP. In this study, 100 patients with ascites due to cirrhosis, with an average age of 38.9 ± 6.54 years were evaluated. Twenty cases had positive results, of whom 17 cases were also detected based on the standard diagnostic criteria and other three cases were healthy individuals. Thus, sensitivity, specificity, positive and negative predictive values, and accuracy of the method were 95%, 96.3%, 85%, 97.5% and 95%, respectively. The use of leukocyte esterase urine dipstick test can be a quick and easy method in early diagnosis of SBP to start the treatment until preparation of SBP-cell count results.

  4. Novel cellulose-based halochromic test strips for naked-eye detection of alkaline vapors and analytes.

    PubMed

    Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir

    2017-08-01

    A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Central tracker for BM@N experiment based on double side Si-microstrip detectors

    NASA Astrophysics Data System (ADS)

    Kovalev, Yu.; Kapishin, M.; Khabarov, S.; Shafronovskaia, A.; Tarasov, O.; Makankin, A.; Zamiatin, N.; Zubarev, E.

    2017-07-01

    Design of central tracker system based on Double-Sided Silicon Detectors (DSSD) for BM@N experiment is described. A coordinate plane with 10240 measuring channels, pitch adapter, reading electronics was developed. Each element was tested and assembled into a coordinate plane. The first tests of the plane with 106Ru source were carried out before installation for the BM@N experiment. The results of the study indicate that noisy channels and inefficient channels are less than 3%. In general, single clusters 87% (one group per module of consecutive strips) and 75% of clusters with a width equal to one strip.

  6. Development of a Paper Strip Test for Detection of Niacin Produced by Mycobacteria

    PubMed Central

    Young, William D.; Maslansky, Alvin; Lefar, Morton S.; Kronish, Donald P.

    1970-01-01

    The development of a reagent-impregnated paper strip test for niacin is described. The test system is based on the formation of cyanogen chloride by the reaction of chloramine-T and potassium thiocyanate in the presence of citric acid. Rupture of the pyridine ring of niacin by cyanogen chloride yields γ-carboxy glutaconic aldehyde and coupling with a primary aromatic amine produces a yellow color. Sensitivity to niacin, both in known solutions and from extracts of 378 clinical mycobacteria isolates, equalled or exceeded that of other methods for detection of niacin. Correlation with other tests for mycobacterial niacin was excellent. PMID:4321713

  7. Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout

    DOE PAGES

    Denisov, Dmitri; Evdokimov, Valery; Lukic, Strahinja; ...

    2016-12-24

    Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Furthermore, light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.

  8. [Quantification study on the runoff and seepage distribution and N, P pollutants removal of the vegetated buffer strips].

    PubMed

    Wang, Min; Huang, Yu-Chi; Wu, Jian-Qiang

    2010-11-01

    By using the constructed buffer strips test base and the runoff hydrometric devices, a research on stagnant runoff and nitrogen (N), phosphorous (P) pollutants removal capacity of the vegetated buffer strips was conducted. The results show that the vegetated buffer strips might reduce the speed of runoff significantly and improve the hydraulic permeability of soil. The runoff water output time of 19 m buffer strips planted with Cynodon dactylon, Festuca arundinacea and Trifolium repens are 2.46, 1.72 and 2.03 times higher than the control (no vegetation) respectively; The seepage water quantity of three vegetation buffer strips are 3.01, 2.16 and 2.45 times higher than the control respectively as well. Total removal efficiency of the three buffer strips increase about 237%, 268% and 274% comparing with the control respectively. The N, P removal capacity of seepage is significantly higher than that of the runoff, the larger seepage water quantity will cause higher N, P total removal efficiency and removal loads of unit area. With different vegetated buffer strips, the TN, NH4(+) -N, TP removal ratio of seepage and runoff are 2.79, 2.02 and 2.83 respectively.

  9. Performance of a new test strip for freestyle blood glucose monitoring systems.

    PubMed

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations <75 mg/dL, 73%, 100%, and 100% of the individual capillary blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  10. Recycling of water-susceptible pavements

    NASA Astrophysics Data System (ADS)

    Maupin, G. W.

    1980-05-01

    Several bituminous concrete interstate pavements that experienced failures suspected to have been caused by stripping were investigated. On two projects, the degree of deterioration, potential serviceability, and possible remedial measures were studied. Cores were taken to determine the degreee of stripping and tensile strength, and dynaflect tests were performed. An emulsion mix design was developed for stripped bituminous concrete removed from another project with the expectation that it could be used as a surface mix on a highway with a low traffic volume. While this expectation was not realized, it was concluded that the material is suitable for use in a base mix. A maintenance resurfacing on a fourth project that experienced stripping failure is being monitored and the performance is being evaluated.

  11. Lot-to-Lot Variability of Test Strips and Accuracy Assessment of Systems for Self-Monitoring of Blood Glucose according to ISO 15197

    PubMed Central

    Baumstark, Annette; Pleus, Stefan; Schmid, Christina; Link, Manuela; Haug, Cornelia; Freckmann, Guido

    2012-01-01

    Background Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. Methods In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), GlucoCheck XL (system C), Pura™/mylife™ Pura (system D), and OneTouch® Verio™ Pro (system E)] were evaluated with procedures according to DIN EN ISO 15197:2003. The BG system measurement results were compared with the manufacturer’s measurement procedure (glucose oxidase or hexokinase method). Relative bias according to Bland and Altman and system accuracy according to ISO 15197 were analyzed. A BG system consists of the BG meter itself and the test strips. Results The maximum lot-to-lot difference between any two of the four evaluated test strip lots per BG system was 1.0% for system E, 2.1% for system A, 3.1% for system C, 6.9% for system B, and 13.0% for system D. Only two systems (systems A and B) fulfill the criteria of DIN EN ISO 15197:2003 with each test strip lot. Conclusions Considerable lot-to-lot variability between test strip lots of the same BG system was found. These variations add to other sources of inaccuracy with the specific BG system. Manufacturers should regularly and effectively check the accuracy of their BG meters and test strips even between different test strip lots to minimize risk of false treatment decisions. PMID:23063033

  12. Interagency Depainting Study Status

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia; Cook, Beth

    1999-01-01

    This document discusses coating removal in general. Sections of this presentation include: regulatory background, the initial parameters of the study, the current parameters of the study, stages in each sequence, preparation of the test specimen, material evaluation testing, chemical stripping, CO2 blasting, Flashjet coating removal, plastic media blasting, sodium bicarbonate wet stripping, water stripping, and wheat starch stripping.

  13. Thermal stability study of a new guanidine suppressor for the next-generation caustic-side solvent extraction process

    DOE PAGES

    Hill, Talon G.; Ensor, Dale D.; Delmau, Lætitia Helene; ...

    2016-02-06

    Cesium stripping performance of thermally stressed solvent degrades slowly over time in batch tests of the Next Generation Caustic-Side Solvent Extraction (NGS) process. NGS is currently used at pilot scale at the Savannah River Site for the selective removal of cesium from high-level salt waste. Recently a new guanidine, N,N',N" -tris(3,7-dimethyloctyl)guanidine (TiDG), was chosen for use as the suppressor, a lipophilic organic base needed for stripping, and the present study was undertaken to address the question of its stability. The NGS process solvent was evaluated for a period of three months under a variety of temperature and storage conditions. Themore » performance of the solvent was tested at 30-day increments using a standard extraction, scrub, strip, and extraction (ES 2S 3E) sequence. Lastly, the results provide insight on the effects of storage and process conditions, the stripping behavior of TiDG, and the stability of the new solvent composition.« less

  14. Thermal stability study of a new guanidine suppressor for the next-generation caustic-side solvent extraction process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Talon G.; Ensor, Dale D.; Delmau, Lætitia Helene

    Cesium stripping performance of thermally stressed solvent degrades slowly over time in batch tests of the Next Generation Caustic-Side Solvent Extraction (NGS) process. NGS is currently used at pilot scale at the Savannah River Site for the selective removal of cesium from high-level salt waste. Recently a new guanidine, N,N',N" -tris(3,7-dimethyloctyl)guanidine (TiDG), was chosen for use as the suppressor, a lipophilic organic base needed for stripping, and the present study was undertaken to address the question of its stability. The NGS process solvent was evaluated for a period of three months under a variety of temperature and storage conditions. Themore » performance of the solvent was tested at 30-day increments using a standard extraction, scrub, strip, and extraction (ES 2S 3E) sequence. Lastly, the results provide insight on the effects of storage and process conditions, the stripping behavior of TiDG, and the stability of the new solvent composition.« less

  15. DEMONSTRATION OF THE NEXT-GENERATION CAUSTIC-SIDE SOLVENT EXTRACTION SOLVENT WITH 2-CM CENTRIFUGAL CONTRACTORS USING TANK 49H WASTE AND WASTE SIMULANT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, R.; Peters, T.; Crowder, M.

    2011-09-27

    Researchers successfully demonstrated the chemistry and process equipment of the Caustic-Side Solvent Extraction (CSSX) flowsheet using MaxCalix for the decontamination of high level waste (HLW). The demonstration was completed using a 12-stage, 2-cm centrifugal contactor apparatus at the Savannah River National Laboratory (SRNL). This represents the first CSSX process demonstration of the MaxCalix solvent system with Savannah River Site (SRS) HLW. Two tests lasting 24 and 27 hours processed non-radioactive simulated Tank 49H waste and actual Tank 49H HLW, respectively. Conclusions from this work include the following. The CSSX process is capable of reducing {sup 137}Cs in high level radioactivemore » waste by a factor of more than 40,000 using five extraction, two scrub, and five strip stages. Tests demonstrated extraction and strip section stage efficiencies of greater than 93% for the Tank 49H waste test and greater than 88% for the simulant waste test. During a test with HLW, researchers processed 39 liters of Tank 49H solution and the waste raffinate had an average decontamination factor (DF) of 6.78E+04, with a maximum of 1.08E+05. A simulant waste solution ({approx}34.5 liters) with an initial Cs concentration of 83.1 mg/L was processed and had an average DF greater than 5.9E+03, with a maximum DF of greater than 6.6E+03. The difference may be attributable to differences in contactor stage efficiencies. Test results showed the solvent can be stripped of cesium and recycled for {approx}25 solvent turnovers without the occurrence of any measurable solvent degradation or negative effects from minor components. Based on the performance of the 12-stage 2-cm apparatus with the Tank 49H HLW, the projected DF for MCU with seven extraction, two scrub, and seven strip stages operating at a nominal efficiency of 90% is {approx}388,000. At 95% stage efficiency, the DF in MCU would be {approx}3.2 million. Carryover of organic solvent in aqueous streams (and aqueous in organic streams) was less than 0.1% when processing Tank 49H HLW. The entrained solvent concentration measured in the decontaminated salt solution (DSS) was as much as {approx}140 mg/L, although that value may be overstated by as much as 50% due to modifier solubility in the DSS. The entrained solvent concentration was measured in the strip effluent (SE) and the results are pending. A steady-state concentration factor (CF) of 15.9 was achieved with Tank 49H HLW. Cesium distribution ratios [D(Cs)] were measured with non-radioactive Tank 49H waste simulant and actual Tank 49H waste. Below is a comparison of D(Cs) values of ESS and 2-cm tests. Batch Extraction-Strip-Scrub (ESS) tests yielded D(Cs) values for extraction of {approx}81-88 for tests with Tank 49H waste and waste simulant. The results from the 2-cm contactor tests were in agreement with values of 58-92 for the Tank 49H HLW test and 54-83 for the simulant waste test. These values are consistent with the reference D(Cs) for extraction of {approx}60. In tests with Tank 49H waste and waste simulant, batch ESS tests measured D(Cs) values for the two scrub stages as {approx}3.5-5.0 for the first scrub stage and {approx}1.0-3.0 for the second scrub stage. In the Tank 49H test, the D(Cs) values for the 2-cm test were far from the ESS values. A D(Cs) value of 161 was measured for the first scrub stage and 10.8 for the second scrub stage. The data suggest that the scrub stage is not operating as effectively as intended. For the simulant test, a D(Cs) value of 1.9 was measured for the first scrub stage; the sample from the second scrub stage was compromised. Measurements of the pH of all stage samples for the Tank 49H test showed that the pH for extraction and scrub stages was 14 and the pH for the strip stages was {approx}7. It is expected that the pH of the second scrub stage would be {approx}12-13. Batch ESS tests measured D(Cs) values for the strip stages to be {approx}0.002-0.010. A high value in Strip No.3 of a test with simulant solution has been attributed to issues associated with the limits of detection for the analytical method. In the 2-cm contactor tests, the first four strip stages of the Tank 49H waste test and all five strip stages in the simulant waste test had higher values than the ESS tests. Only the fifth strip stage D(Cs) value of the Tank 49H waste test matched that of the ESS tests. It is speculated that the less-than-optimal performance of the strip section is caused by inefficiencies in the scrub section. Because strip is sensitive to pH, the elevated pH value in the second scrub stage may be the cause of strip performance. In spite of the D(Cs) values obtained in the scrub and strip sections, testing showed that the solvent system is robust. Average DFs for the process far exceeded targets even though the scrub and strip stages did not function optimally. Correction of the issue in the scrub and strip stages is expected to yield even higher waste DFs.« less

  16. Diagnostic accuracy of self-administered urine glucose test strips as a diabetes screening tool in a low-resource setting in Cambodia.

    PubMed

    Storey, Helen L; van Pelt, Maurits H; Bun, Socheath; Daily, Frances; Neogi, Tina; Thompson, Matthew; McGuire, Helen; Weigl, Bernhard H

    2018-03-22

    Screening for diabetes in low-resource countries is a growing challenge, necessitating tests that are resource and context appropriate. The aim of this study was to determine the diagnostic accuracy of a self-administered urine glucose test strip compared with alternative diabetes screening tools in a low-resource setting of Cambodia. Prospective cross-sectional study. Members of the Borey Santepheap Community in Cambodia (Phnom Penh Municipality, District Dangkao, Commune Chom Chao). All households on randomly selected streets were invited to participate, and adults at least 18 years of age living in the study area were eligible for inclusion. The accuracy of self-administered urine glucose test strip positivity, Hemoglobin A1c (HbA1c)>6.5% and capillary fasting blood glucose (cFBG) measurement ≥126 mg/dL were assessed against a composite reference standard of cFBGmeasurement ≥200 mg/dL or venous blood glucose 2 hours after oral glucose tolerance test (OGTT) ≥200 mg/dL. Of the 1289 participants, 234 (18%) had diabetes based on either cFBG measurement (74, 32%) or the OGTT (160, 68%). The urine glucose test strip was 14% sensitive and 99% specific and failed to identify 201 individuals with diabetes while falsely identifying 7 without diabetes. Those missed by the urine glucose test strip had lower venous fasting blood glucose, lower venous blood glucose 2 hours after OGTT and lower HbA1c compared with those correctly diagnosed. Low cost, easy to use diabetes tools are essential for low-resource communities with minimal infrastructure. While the urine glucose test strip may identify persons with diabetes that might otherwise go undiagnosed in these settings, its poor sensitivity cannot be ignored. The massive burden of diabetes in low-resource settings demands improvements in test technologies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. A silicon dioxide modified magnetic nanoparticles-labeled lateral flow strips for HBs antigen.

    PubMed

    Zhang, Xueqing; Jiang, Lin; Zhang, Chunlei; Li, Ding; Wang, Can; Gao, Feng; Cui, Daxiang

    2011-12-01

    Herein we reported a new type of silicon dioxide wrapped magnetic nanoparticles-labeled lateral flow strip for detection of HBs antigen in sera. The SiO2 wrapped Fe3O4 nanocomposites were prepared and characterized by HR-TEM, FTIR and magnetometer. As-prepared nanocomposites were used to label anti-HBV surface monoclonal antibody, the lateral flow strips were constructed, and 100 specimens of sera were collected and tested. Results showed that the prepared SiO2 wrapped Fe3O4 nanocomposites were shell/core structure, well dispersed, with the size of 25 nm in diameter, the thickness of the shell was about 3 nm, their magnetic saturation intensity was 44.3 meu g(-1). Clinical sera specimens test results showed that the prepared lateral flow strips were with the detection limitation of 5 pg/mL by naked eye observation, and 0.1 pg/mL by CCD reader or MAR Analyzer, specificity was 100%. In conclusion, one kind of silicon dioxide wrapped magnetic nanoparticles-labeled lateral flow strip for ultrasensitive detection of HBs antigen was successfully developed, its ease of use, sensitiveness and low-cost make it well-suited for population-based on-the-site hepatitis B screening.

  18. In vitro and in vivo evaluation of diamond-coated strips.

    PubMed

    Lione, Roberta; Gazzani, Francesca; Pavoni, Chiara; Guarino, Stefano; Tagliaferri, Vincenzo; Cozza, Paola

    2017-05-01

    To test in vitro and in vivo the wear performance of diamond-coated strips by means of tribological testing and scanning electronic microscope (SEM). To evaluate the in vitro wear performance, a tribological test was performed by a standard tribometer. The abrasive strips slid against stationary, freshly extracted premolars fixed in resin blocks, at a 2-newton load. At the end of the tribological test, the residual surface of the strip was observed by means of SEM analysis, which was performed every 50 meters until reaching 300 meters. For the in vivo analysis, the strip was used for 300 seconds, corresponding to 250 meters. The strips presented a fenestrated structure characterized by diamond granules alternating with voids. After the first 50 meters, it was possible to observe tooth material deposited on the surface of the strips and a certain number of abrasive grains detached. The surface of the strip after 250 meters appeared smoother and therefore less effective in its abrasive power. After 300 seconds of in vivo utilization of the strip, it was possible to observe the detachment of diamond abrasive grains, the near absence of the grains and, therefore, loss of abrasive power. Under ideal conditions, after 5 minutes (30 meters) of use, the strip loses its abrasive capacity by about 60%. In vivo, a more rapid loss of abrasive power was observed due to the greater load applied by the clinician in forcing the strip into the contact point.

  19. A test for measuring gustatory function.

    PubMed

    Smutzer, Gregory; Lam, Si; Hastings, Lloyd; Desai, Hetvi; Abarintos, Ray A; Sobel, Marc; Sayed, Nabil

    2008-08-01

    The purpose of this study was to determine the usefulness of edible taste strips for measuring human gustatory function. The physical properties of edible taste strips were examined to determine their potential for delivering threshold and suprathreshold amounts of taste stimuli to the oral cavity. Taste strips were then assayed by fluorescence to analyze the uniformity and distribution of bitter tastant in the strips. Finally, taste recognition thresholds for sweet taste were examined to determine whether or not taste strips could detect recognition thresholds that were equal to or better than those obtained from aqueous tests. Edible strips were prepared from pullulan-hydroxypropyl methylcellulose solutions that were dried to a thin film. The maximal amount of a tastant that could be incorporated in a 2.54 cm2 taste strip was identified by including representative taste stimuli for each class of tastant (sweet, sour, salty, bitter, and umami) during strip formation. Distribution of the bitter tastant quinine hydrochloride in taste strips was assayed by fluorescence emission spectroscopy. The efficacy of taste strips for evaluating human gustatory function was examined by using a single series ascending method of limits protocol. Sucrose taste recognition threshold data from edible strips was then compared with results that were obtained from a standard "sip and spit" recognition threshold test. Edible films that formed from a pullulan-hydroxypropyl methylcellulose polymer mixture can be used to prepare clear, thin strips that have essentially no background taste and leave no physical presence after release of tastant. Edible taste strips could uniformly incorporate up to 5% of their composition as tastant. Taste recognition thresholds for sweet taste were over one order of magnitude lower with edible taste strips when compared with an aqueous taste test. Edible taste strips are a highly sensitive method for examining taste recognition thresholds in humans. This new means of presenting taste stimuli should have widespread applications for examining human taste function in the laboratory, in the clinic, or at remote locations.

  20. Guidelines for the application of removeable rumble strips

    DOT National Transportation Integrated Search

    2006-08-01

    This work was initiated to assess the viability of removable rumble strips as replacements for asphalt rumble strips, particularly in short term highway work zones. The two rumble strips tested were the Orange Rumble Strip from Advanced Traffic Marki...

  1. Development of a Colloidal Gold-Based Immunochromatographic Strip for Rapid Detection of Klebsiella pneumoniae Serotypes K1 and K2

    PubMed Central

    Siu, L. Kristopher; Tsai, Yu-Kuo; Lin, Jung-Chung; Chen, Te-Li; Fung, Chang-Phone

    2016-01-01

    In this study, a novel colloidal gold-based immunochromatographic strip (ICS) containing anti-Klebsiella pneumoniae capsular polysaccharide polyclonal antibodies was developed to specifically detect K. pneumoniae serotypes K1 and K2. Capsular polysaccharide K1 and K2 antigens were first used to produce polyclonal anti-K1 and anti-K2 antibodies. Reference strains with different serotypes, nontypeable K. pneumoniae strains, and other bacterial species were then used to assess the sensitivity and specificity of these test strips. The detection limit was found to be 105 CFU, and the ICSs were stable for 6 months when stored at room temperature. No false-positive or false-negative results were observed, and equivalent results were obtained compared to those of more conventional test methods, such as PCR or serum agglutination. In conclusion, the ICS developed here requires no technical expertise and allows for the specific, rapid, and simultaneous detection of K. pneumoniae serotypes K1 and K2. PMID:27707941

  2. A test strip platform based on DNA-functionalized gold nanoparticles for on-site detection of mercury (II) ions.

    PubMed

    Guo, Zhiyong; Duan, Jing; Yang, Fei; Li, Min; Hao, Tingting; Wang, Sui; Wei, Danyi

    2012-05-15

    A test strip, based on DNA-functionalized gold nanoparticles for Hg(2+) detection, has been developed, optimized and validated. The developed colorimetric mercury sensor system exhibited a highly sensitive and selective response to mercury. The measurement principle is based on thymine-Hg(2+)-thymine (T-Hg(2+)-T) coordination chemistry and streptavidin-biotin interaction. A biotin-labeled and thiolated DNA was immobilized on the gold nanoparticles (AuNPs) surface through a self-assembling method. Another thymine-rich DNA, which was introduced to form DNA duplexes on the AuNPs surface with thymine-Hg(2+)-thymine (T-Hg(2+)-T) coordination in the presence of Hg(2+), was immobilized on the nitrocellulose membrane as the test zone. When Hg(2+) ions were introduced into this system, they induced the two strands of DNA to intertwist by forming T-Hg(2+)-T bonds resulting in a red line at the test zone. The biotin-labeled and thiolated DNA-functionalized AuNPs could be captured by streptavidin which was immobilized on the nitrocellulose membrane as the control zone. Under optimized conditions, the detection limit for Hg(2+) was 3 nM, which is lower than the 10nM, maximum contaminant limit defined by the US Environmental Protection Agency (EPA) for drinking water. A parallel analysis of Hg(2+) in pool water samples using cold vapor atomic absorption spectrometry showed comparable results to those obtained from the strip test. Therefore, the results obtained in this study could be used as basic research for the development of Hg(2+) detection, and the method developed could be a potential on-site screening tool for the rapid detection of Hg(2+) in different water samples without special instrumentation. All experimental variables that influence the test strip response were optimized and reported. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. CdSe/ZnS Quantum Dot-Labeled Lateral Flow Strips for Rapid and Quantitative Detection of Gastric Cancer Carbohydrate Antigen 72-4

    NASA Astrophysics Data System (ADS)

    Yan, Xinyu; Wang, Kan; Lu, Wenting; Qin, Weijian; Cui, Daxiang; He, Jinghua

    2016-03-01

    Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.

  4. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  5. Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Francis, K.; Repond, J.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S. T.; Sosebee, M.; White, A. P.; Yu, J.; Eigen, G.; Mikami, Y.; Watson, N. K.; Thomson, M. A.; Ward, D. R.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Ribon, A.; Uzhinskiy, V.; Cârloganu, C.; Gay, P.; Manen, S.; Royer, L.; Tytgat, M.; Zaganidis, N.; Blazey, G. C.; Dyshkant, A.; Lima, J. G. R.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; Cornett, U.; David, D.; Ebrahimi, A.; Falley, G.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Karstensen, S.; Krivan, F.; Krüger, K.; Lutz, B.; Morozov, S.; Morgunov, V.; Neubüser, C.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Garutti, E.; Laurien, S.; Lu, S.; Marchesini, I.; Matysek, M.; Ramilli, M.; Briggl, K.; Eckert, P.; Harion, T.; Schultz-Coulon, H.-Ch.; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Sudo, Y.; Yoshioka, T.; Dauncey, P. D.; Wing, M.; Salvatore, F.; Cortina Gil, E.; Mannai, S.; Baulieu, G.; Calabria, P.; Caponetto, L.; Combaret, C.; Della Negra, R.; Grenier, G.; Han, R.; Ianigro, J.-C.; Kieffer, R.; Laktineh, I.; Lumb, N.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Tromeur, W.; Vander Donckt, M.; Zoccarato, Y.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Corriveau, F.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Besson, D.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Weuste, L.; Amjad, M. S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph.; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch.; Pöschl, R.; Raux, L.; Rouëné, J.; Seguin-Moreau, N.; Anduze, M.; Balagura, V.; Boudry, V.; Brient, J.-C.; Cornat, R.; Frotin, M.; Gastaldi, F.; Guliyev, E.; Haddad, Y.; Magniette, F.; Musat, G.; Ruan, M.; Tran, T. H.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Kotera, K.; Ono, H.; Takeshita, T.; Uozumi, S.; Jeans, D.; Chang, S.; Khan, A.; Kim, D. H.; Kong, D. J.; Oh, Y. D.; Götze, M.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2014-11-01

    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of this type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

  6. Practical color vision tests for air traffic control applicants: en route center and terminal facilities.

    PubMed

    Mertens, H W; Milburn, N J; Collins, W E

    2000-12-01

    Two practical color vision tests were developed and validated for use in screening Air Traffic Control Specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulation of color-coded materials from the most demanding, safety-critical color task performed in each type of facility. The tests were evaluated using 106 subjects with normal color vision and 85 with color vision deficiency. The en route center test, named the Flight Progress Strips Test (FPST), required the identification of critical red/black coding in computer printing and handwriting on flight progress strips. The terminal option test, named the Aviation Lights Test (ALT), simulated red/green/white aircraft lights that must be identified in night ATC tower operations. Color-coding is a non-redundant source of safety-critical information in both tasks. The FPST was validated by direct comparison of responses to strip reproductions with responses to the original flight progress strips and a set of strips selected independently. Validity was high; Kappa = 0.91 with original strips as the validation criterion and 0.86 with different strips. The light point stimuli of the ALT were validated physically with a spectroradiometer. The reliabilities of the FPST and ALT were estimated with Chronbach's alpha as 0.93 and 0.98, respectively. The high job-relevance, validity, and reliability of these tests increases the effectiveness and fairness of ATCS color vision testing.

  7. Assessment of the diagnostic value of a urinary adipsin rapid strip test for pre-eclampsia: A prospective multicenter study.

    PubMed

    Peng, Bing; Zhang, Li; Yan, Jianying; Qi, Hongbo; Zhang, Weiyuan; Fan, Ling; Hu, Yayi; Lin, Li; Li, Xiaotian; Hu, Rong; Xie, Lan; Zhang, Jianping; Wu, Yanqiao; Li, Li; Zhou, Rong

    2017-01-01

    The purpose of the present study was to evaluate the clinical value of the rapid strip test of urinary adipsin for the quick diagnosis of pre-eclampsia. In a multicenter diagnostic test study, we studied the diagnostic accuracy of the rapid strip test of urinary adipsin in women presenting with pre-eclampsia. A total of 204 pre-eclampsia patients and 254 healthy pregnant women were recruited for this study, respectively. The rapid strip test of urinary adipsin was used to detect the adipsin in the urine of each patient. The diagnostic value of the rapid strip test of urinary adipsin for pre-eclampsia was demonstrated by its high sensitivity and specificity (95.10% and 97.64%, respectively). The diagnostic accuracy was 96.51%. The consistency analysis showed that the kappa value was 0.93 compared with the gold standard diagnosis of pre-eclampsia. The rapid strip test of urinary adipsin is a non-invasive test for the diagnosis of pre-eclampsia with high sensitivity and specificity. It could help the quick diagnosis of pre-eclampsia in clinical practice greatly. © 2016 Japan Society of Obstetrics and Gynecology.

  8. Hands-On Science: Is It an Acid or a Base? These Colorful Tests Tell All!

    ERIC Educational Resources Information Center

    VanCleave, Janice

    1998-01-01

    Two hands-on science activities for K-6 students teach them how to determine if something is an acid or a base. The activities require acid/base indicator juice, testing strips, and a base solution. A recipe for making them in the classroom using red cabbage and baking soda is provided. (SM)

  9. Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels.

    PubMed

    Guo, Jinhong; Ma, Xing

    2017-08-15

    The conventional test strip has usually only one electrochemical reaction channel, which requires two times figure punctures for the self-management of patients suffering from both diabetes and gout. Considering the large number of such patients and for the sake of reducing their pains, we report an enzymatic test strip which can simultaneously monitor glucose and uric acid (UA) with only one fingertip blood droplet. The proposed test strip is composed of dual channels. The glucose in blood is detected in the 1st channel above on the substrate and the UA is characterized in the 2nd channel located at the bottom of the substrate. The proposed design intensively matches the requirement of those patients simultaneously suffering from diabetes and gout. We carried out comparative investigations on the proposed test strip and clinical biochemical analyser, which indicates a good agreement and proved the reliability and accuracy of the proposed test strip, as promising solution for the fast growth of family health management market. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Simultaneous quantitation of cytokeratin-19 fragment and carcinoembryonic antigen in human serum via quantum dot-doped nanoparticles.

    PubMed

    Chen, Zhenhua; Liang, Rongliang; Guo, Xinxin; Liang, Junyu; Deng, Qiaoting; Li, Min; An, Taixue; Liu, Tiancai; Wu, Yingsong

    2017-05-15

    A novel quantum dot-doped polystyrene nanoparticles-based lateral flow test strips (QPs-LFTS) system was developed to simultaneously detect a cytokeratin-19 fragment (CYFRA 21-1) and carcinoembryonic antigen (CEA) in human serum to aid the diagnosis and prognosis of lung cancer. Quantum dot-doped carboxylate-functionalized polystyrene nanoparticles (QPs) were prepared and introduced as fluorescent reporters in QPs-LFTS. The detection was based on a sandwich immunoassay and performed on lateral flow test strips, with an assay time of 15min. The strips were read by a fluorescence strip reader to obtain the fluorescence peak heights of the test lines (H T ) and the control line (H C ). The ratio of H T /H C was used for quantitation. The QPs showed excellent photoproperties and good performance. Under optimal conditions, the QPs-LFTS system exhibited a wide linear range for CYFRA 21-1 (1.3-480ng/mL) and CEA (2.8-680ng/mL). The detection limits for CYFRA 21-1 and CEA were 0.16 and 0.35ng/mL, respectively. The recovery and reproducibility of the method were satisfactory. Furthermore, excellent correlations (n =120, R 2 =0.9862, P<0.0001 for CYFRA 21-1; n =70, R 2 =0.9509, P<0.0001 for CEA) were obtained between the QPs-LFTS and commercially available chemiluminescence immunoassay kits in clinical serum testing. The results indicate that this developed test system is highly efficient and is expected to be useful for early screening and prognosis evaluation for lung cancer patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Low material budget floating strip Micromegas for ion transmission radiography

    NASA Astrophysics Data System (ADS)

    Bortfeldt, J.; Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph.; Magallanes, L.; Müller, R.; Parodi, K.; Schlüter, T.; Voss, B.; Zibell, A.

    2017-02-01

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm2 with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X0. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF4 gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  12. Magnetic-Force-Assisted Straightening of Bent Mild Steel Strip by Laser Irradiation

    NASA Astrophysics Data System (ADS)

    Dutta, Polash P.; Kalita, Karuna; Dixit, Uday S.; Liao, Hengcheng

    2017-12-01

    This study proposes a technique to straighten bent metallic strips with magnetic-force-assisted laser irradiation. Experiments were conducted for three different types of mechanically-bent mild strips. The first type was bent strips without any heat treatment. The second type was stress-relieved and third type was subcritical-annealed bent strips. These strips were straightened following different schemes of laser irradiation sequence to understand the performance of straightening. A parametric study was conducted by varying laser power and scanning speed. Micro-hardness, tensile test, Charpy impact test and microstructure after straightening were also studied. Different scanning schemes provided different microstructures and mechanical properties. Any serious deterioration in the quality of straightened strips was not noticed. Overall, subcritical-annealed bent strips provided the best performance in straightening. The proposed straightening scheme has potential of becoming an industrial practice.

  13. Measurement of gamma quantum interaction point in plastic scintillator with WLS strips

    NASA Astrophysics Data System (ADS)

    Smyrski, J.; Alfs, D.; Bednarski, T.; Białas, P.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Jasińska, B.; Kajetanowicz, M.; Kamińska, D.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Salabura, P.; Silarski, M.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.; Wojnarska, J.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    2017-04-01

    The feasibility of measuring the aśxial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of wavelength-shifting (WLS) strips is demonstrated. Using a test set-up comprising a BC-420 scintillator bar and an array of sixteen BC-482A WLS strips we achieved a spatial resolution of 5 mm (σ) for annihilation photons from a 22Na isotope. The studied method can be used to improve the spatial resolution of a plastic-scintillator-based PET scanner which is being developed by the J-PET collaboration.

  14. A preference test for sweet taste that uses edible strips.

    PubMed

    Smutzer, Gregory; Patel, Janki Y; Stull, Judith C; Abarintos, Ray A; Khan, Neiladri K; Park, Kevin C

    2014-02-01

    A novel delivery method is described for the rapid determination of taste preferences for sweet taste in humans. This forced-choice paired comparison approach incorporates the non-caloric sweetener sucralose into a set of one-inch square edible strips for the rapid determination of sweet taste preferences. When compared to aqueous sucrose solutions, significantly lower amounts of sucralose were required to identify the preference for sweet taste. The validity of this approach was determined by comparing sweet taste preferences obtained with five different sucralose-containing edible strips to a set of five intensity-matched sucrose solutions. When compared to the solution test, edible strips required approximately the same number of steps to identify the preferred amount of sweet taste stimulus. Both approaches yielded similar distribution patterns for the preferred amount of sweet taste stimulus. In addition, taste intensity values for the preferred amount of sucralose in strips were similar to that of sucrose in solution. The hedonic values for the preferred amount of sucralose were lower than for sucrose, but the taste quality of the preferred sucralose strip was described as sweet. When taste intensity values between sucralose strips and sucralose solutions containing identical amounts of taste stimulus were compared, sucralose strips produced a greater taste intensity and more positive hedonic response. A preference test that uses edible strips for stimulus delivery should be useful for identifying preferences for sweet taste in young children, and in clinical populations. This test should also be useful for identifying sweet taste preferences outside of the lab or clinic. Finally, edible strips should be useful for developing preference tests for other primary taste stimuli and for taste mixtures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. A Preference Test for Sweet Taste That Uses Edible Strips

    PubMed Central

    Smutzer, Gregory; Patel, Janki Y.; Stull, Judith C.; Abarintos, Ray A.; Khan, Neiladri K.; Park, Kevin C.

    2014-01-01

    A novel delivery method is described for the rapid determination of taste preferences for sweet taste in humans. This forced-choice paired comparison approach incorporates the non-caloric sweetener sucralose into a set of one-inch square edible strips for the rapid determination of sweet taste preferences. When compared to aqueous sucrose solutions, significantly lower amounts of sucralose were required to identify the preference for sweet taste. The validity of this approach was determined by comparing sweet taste preferences obtained with five different sucralose-containing edible strips to a set of five intensity-matched sucrose solutions. When compared to the solution test, edible strips required approximately the same number of steps to identify the preferred amount of sweet taste stimulus. Both approaches yielded similar distribution patterns for the preferred amount of sweet taste stimulus. In addition, taste intensity values for the preferred amount of sucralose in strips were similar to that of sucrose in solution. The hedonic values for the preferred amount of sucralose were lower than for sucrose, but the taste quality of the preferred sucralose strip was described as sweet. When taste intensity values between sucralose strips and sucralose solutions containing identical amounts of taste stimulus were compared, sucralose strips produced a greater taste intensity and more positive hedonic response. A preference test that uses edible strips for stimulus delivery should be useful for identifying preferences for sweet taste in young children, and in clinical populations. This test should also be useful for identifying sweet taste preferences outside of the lab or clinic. Finally, edible strips should be useful for developing preference tests for other primary taste stimuli and for taste mixtures. PMID:24225255

  16. Detection of aflatoxin B₁ with immunochromatographic test strips: Enhanced signal sensitivity using gold nanoflowers.

    PubMed

    Ji, Yanwei; Ren, Meiling; Li, Yanping; Huang, Zhibing; Shu, Mei; Yang, Hongwei; Xiong, Yonghua; Xu, Yang

    2015-09-01

    Immunochromatographic test strips (ICTS) are commonly limited to higher concentrations of analytes. This limitation stems from the relatively low sensitivity of conventional gold nanospheres (AuNSs with a diameter of 20 nm) to emit detectable brightness values. The larger multi-branched gold nanoflowers (AuNFs) with a higher optical brightness as well as good colloidal stability exhibit significant improvements over conventional AuNSs for enhanced sensitivity of ICTS. In this study, blue AuNFs with an average diameter of 75±5 nm were synthetized and employed as a signal amplification probe for ultrasensitive and quantitative detection of aflatoxin B1 (AFB1) in rice. A portable optical strip reader was used to record the optical densities of test and control lines of the strip. Under the optimal conditions, the AuNF based ICTS system accurately detected AFB1 linearly and dynamically over the range of 0.5-25 pg/mL with a half maximal inhibitory concentration at 4.17 pg/mL. The inhibitory concentration was achieved 10 times lower than that of the traditional AuNS based ICTS systems (41.25 pg/mL). The limit of detection for AFB1 in rice extract was achieved at 0.32 pg/mL. In summary, AuNFs are a novel probe that exhibited excellent sensitivity in the ICTS system and could be used for ultrasensitive detection of other analytes in food safety monitoring, and even medical diagnostics. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Utilizing the ultrasensitive Schistosoma up-converting phosphor lateral flow circulating anodic antigen (UCP-LF CAA) assay for sample pooling-strategies.

    PubMed

    Corstjens, Paul L A M; Hoekstra, Pytsje T; de Dood, Claudia J; van Dam, Govert J

    2017-11-01

    Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination.

  18. Electrospin-coating of nitrocellulose membrane enhances sensitivity in nucleic acid-based lateral flow assay.

    PubMed

    Yew, Chee-Hong Takahiro; Azari, Pedram; Choi, Jane Ru; Li, Fei; Pingguan-Murphy, Belinda

    2018-06-07

    Point-of-care biosensors are important tools developed to aid medical diagnosis and testing, food safety and environmental monitoring. Paper-based biosensors, especially nucleic acid-based lateral flow assays (LFA), are affordable, simple to produce and easy to use in remote settings. However, the sensitivity of such assays to infectious diseases has always been a restrictive challenge. Here, we have successfully electrospun polycaprolactone (PCL) on nitrocellulose (NC) membrane to form a hydrophobic coating to reduce the flow rate and increase the interaction rate between the targets and gold nanoparticles-detecting probes conjugates, resulting in the binding of more complexes to the capture probes. With this approach, the sensitivity of the PCL electrospin-coated test strip has been increased by approximately ten-fold as compared to the unmodified test strip. As a proof of concept, this approach holds great potential for sensitive detection of targets at point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A Novel Quantum Dots-Based Point of Care Test for Syphilis

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang

    2010-05-01

    One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.

  20. Experimental and modelling study of the effect of airflow orientation with respect to strip electrode on ozone production of surface dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Mikeš, J.; Pekárek, S.; Soukup, I.

    2016-11-01

    This study examines the effect of airflow orientation with respect to the strip active electrode on concentration of ozone and nitrogen dioxide produced in a planar generator based on the surface dielectric barrier discharge. The orientation of the airflow was tested in parallel and perpendicular with respect to the strips. It was found that in the investigated range of average discharge power, the ozone concentration increases approximately by 25% when airflow was oriented in parallel with respect to the strips in comparison with perpendicular orientation of the airflow. Similarly the increase of nitrogen dioxide concentration was observed for parallel orientation of the airflow with respect to the strips in comparison with the perpendicular orientation of the airflow. Within the range of wavelengths from 250 to 1100 nm, the changes of intensities of spectral lines associated with airflow orientation have been observed. A 3D numerical model describing ion trajectories and airflow patterns have also been developed.

  1. Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    DOE PAGES

    Francis, K.; Repond, J.; Schlereth, J.; ...

    2014-11-01

    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45 × 10 × 3 mm³ plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of thismore » type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.« less

  2. Automatic Brain Portion Segmentation From Magnetic Resonance Images of Head Scans Using Gray Scale Transformation and Morphological Operations.

    PubMed

    Somasundaram, Karuppanagounder; Ezhilarasan, Kamalanathan

    2015-01-01

    To develop an automatic skull stripping method for magnetic resonance imaging (MRI) of human head scans. The proposed method is based on gray scale transformation and morphological operations. The proposed method has been tested with 20 volumes of normal T1-weighted images taken from Internet Brain Segmentation Repository. Experimental results show that the proposed method gives better results than the popular skull stripping methods Brain Extraction Tool and Brain Surface Extractor. The average value of Jaccard and Dice coefficients are 0.93 and 0.962 respectively. In this article, we have proposed a novel skull stripping method using intensity transformation and morphological operations. This is a low computational complexity method but gives competitive or better results than that of the popular skull stripping methods Brain Surface Extractor and Brain Extraction Tool.

  3. Rapid onsite detection of bacterial spores of biothreat importance by paper-based colorimetric method using erbium-pyrocatechol violet complex.

    PubMed

    Shivakiran, M S; Venkataramana, M; Lakshmana Rao, P V

    2016-01-01

    Dipicolinic acid (DPA) is an important chemical marker for the detection of bacterial spores. In this study, complexes of lanthanide series elements such as erbium, europium, neodymium, and terbium were prepared with pyrocatechol violet and effectively immobilized the pyrocatechol violet (PV)-metal complex on a filter paper using polyvinyl alcohol. These filter paper strips were employed for the onsite detection of bacterial spores. The test filter papers were evaluated quantitatively with different concentrations of DPA and spores of various bacteria. Among the four lanthanide ions, erbium displayed better sensitivity than the other ions. The limit of detection of this test for DPA was 60 μM and 5 × 10(6) spores. The effect of other non-spore-forming bacteria and interfering chemicals on the test strips was also evaluated. The non-spore-forming bacteria did not have considerable effect on the test strip whereas chemicals such as EDTA had significant effects on the test results. The present test is rapid and robust, capable of providing timely results for better judgement to save resources on unnecessary decontamination procedures during false alarms.

  4. An assessment of buffer strips for improving damage tolerance of composite laminates at elevated temperature

    NASA Technical Reports Server (NTRS)

    Bigelow, C. A.

    1981-01-01

    Buffer strips greatly improve the damage tolerance of graphite/epoxy laminates loaded in tension. Graphite/polyimide buffer strip panels were made and tested to determine their residual strength at ambient and elevated (177 C) temperature. Each panel was cut in the center to represent damage. Panels were radiographed and crack-opening displacements were recorded to indicate fracture, fracture arrest, and the extent of damage in the buffer strip after arrest. All panels had the same buffer strip spacing and width. The buffer strip material was 0 deg S-glass/PMR-15. The buffer strips were made by replacing narrow strips of the 0 deg graphite plies with strips of the 0 deg S-glass on either a one-for-one or a two-for-one basis. Half of the panels were heated to 177 + or - 3 C before and during the testing. Elevated temperature did not alter the fracture behavior of the buffer configuration.

  5. Lateral Flow Assay Based on Paper-Hydrogel Hybrid Material for Sensitive Point-of-Care Detection of Dengue Virus.

    PubMed

    Choi, Jane Ru; Yong, Kar Wey; Tang, Ruihua; Gong, Yan; Wen, Ting; Yang, Hui; Li, Ang; Chia, Yook Chin; Pingguan-Murphy, Belinda; Xu, Feng

    2017-01-01

    Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previousmore » ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.« less

  7. Robust Skull-Stripping Segmentation Based on Irrational Mask for Magnetic Resonance Brain Images.

    PubMed

    Moldovanu, Simona; Moraru, Luminița; Biswas, Anjan

    2015-12-01

    This paper proposes a new method for simple, efficient, and robust removal of the non-brain tissues in MR images based on an irrational mask for filtration within a binary morphological operation framework. The proposed skull-stripping segmentation is based on two irrational 3 × 3 and 5 × 5 masks, having the sum of its weights equal to the transcendental number π value provided by the Gregory-Leibniz infinite series. It allows maintaining a lower rate of useful pixel loss. The proposed method has been tested in two ways. First, it has been validated as a binary method by comparing and contrasting with Otsu's, Sauvola's, Niblack's, and Bernsen's binary methods. Secondly, its accuracy has been verified against three state-of-the-art skull-stripping methods: the graph cuts method, the method based on Chan-Vese active contour model, and the simplex mesh and histogram analysis skull stripping. The performance of the proposed method has been assessed using the Dice scores, overlap and extra fractions, and sensitivity and specificity as statistical methods. The gold standard has been provided by two neurologist experts. The proposed method has been tested and validated on 26 image series which contain 216 images from two publicly available databases: the Whole Brain Atlas and the Internet Brain Segmentation Repository that include a highly variable sample population (with reference to age, sex, healthy/diseased). The approach performs accurately on both standardized databases. The main advantage of the proposed method is its robustness and speed.

  8. A dip-and-read test strip for the determination of mercury(II) ion in aqueous samples based on urease activity inhibition.

    PubMed

    Shi, Guo-Qing; Jiang, Guibin

    2002-11-01

    A sensitive dip-and-read test strip for the determination of mercury in aqueous samples based on the inhibition of urease reaction by the ion has been developed. The strip has a circular sensing zone that containing two layers: the top layer is a cellulose acetate membrane where urease is immobilized on it; the bottom layer is a pH indicator wafer that is impregnated with urea. The principle of the measurement is based on the disappearance of a yellow spot on the pH indicator wafer. The elapsing time until the disappearance of the spot which depends on the concentration of mercury(II) ion is measured with a stopwatch. Under the experimental conditions, as low as 0.2 ng/ml mercury can be observed with the detection range from 0.2 to 200 ng/ml in water. Organomercury compounds give essentially the same response as inorganic mercury. Heavy-metal ions such as Ag(I), Cu(II), Cd(II), Ni(II), Zn(II), and Pb(II) as well as other sample matrixes basically do not interfere with the mercury measurement.

  9. Material Science

    NASA Image and Video Library

    2003-05-05

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  10. Development of a Colloidal Gold-Based Immunochromatographic Strip for Rapid Detection of Klebsiella pneumoniae Serotypes K1 and K2.

    PubMed

    Siu, L Kristopher; Tsai, Yu-Kuo; Lin, Jung-Chung; Chen, Te-Li; Fung, Chang-Phone; Chang, Feng-Yee

    2016-12-01

    In this study, a novel colloidal gold-based immunochromatographic strip (ICS) containing anti-Klebsiella pneumoniae capsular polysaccharide polyclonal antibodies was developed to specifically detect K. pneumoniae serotypes K1 and K2. Capsular polysaccharide K1 and K2 antigens were first used to produce polyclonal anti-K1 and anti-K2 antibodies. Reference strains with different serotypes, nontypeable K. pneumoniae strains, and other bacterial species were then used to assess the sensitivity and specificity of these test strips. The detection limit was found to be 10 5 CFU, and the ICSs were stable for 6 months when stored at room temperature. No false-positive or false-negative results were observed, and equivalent results were obtained compared to those of more conventional test methods, such as PCR or serum agglutination. In conclusion, the ICS developed here requires no technical expertise and allows for the specific, rapid, and simultaneous detection of K. pneumoniae serotypes K1 and K2. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  11. Generalized thick strip modelling for vortex-induced vibration of long flexible cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bao, Y., E-mail: ybao@sjtu.edu.cn; Department of Aeronautics, Imperial College London, South Kensington Campus, London; Palacios, R., E-mail: r.palacios@imperial.ac.uk

    2016-09-15

    We propose a generalized strip modelling method that is computationally efficient for the VIV prediction of long flexible cylinders in three-dimensional incompressible flow. In order to overcome the shortcomings of conventional strip-theory-based 2D models, the fluid domain is divided into “thick” strips, which are sufficiently thick to locally resolve the small scale turbulence effects and three dimensionality of the flow around the cylinder. An attractive feature of the model is that we independently construct a three-dimensional scale resolving model for individual strips, which have local spanwise scale along the cylinder's axial direction and are only coupled through the structural modelmore » of the cylinder. Therefore, this approach is able to cover the full spectrum for fully resolved 3D modelling to 2D strip theory. The connection between these strips is achieved through the calculation of a tensioned beam equation, which is used to represent the dynamics of the flexible body. In the limit, however, a single “thick” strip would fill the full 3D domain. A parallel Fourier spectral/hp element method is employed to solve the 3D flow dynamics in the strip-domain, and then the VIV response prediction is achieved through the strip–structure interactions. Numerical tests on both laminar and turbulent flows as well as the comparison against the fully resolved DNS are presented to demonstrate the applicability of this approach.« less

  12. DipTest: A litmus test for E. coli detection in water.

    PubMed

    Gunda, Naga Siva Kumar; Dasgupta, Saumyadeb; Mitra, Sushanta K

    2017-01-01

    We have developed a new litmus paper test (DipTest) for detecting Escherichia coli (E. coli) in water samples by performing enzymatic reactions directly on the porous paper substrate. The paper strip consists of a long narrow piece of cellulose blotting paper coated with chemoattractant (at bottom edge), wax hydrophobic barrier (at the top edge), and custom formulated chemical reagents (at reaction zone immediately below the wax hydrophobic barrier). When the paper strip is dipped in water, E. coli in the water sample is attracted toward the paper strip due to a chemotaxic mechanism followed by the ascent along the paper strip toward the reaction zone due to a capillary wicking mechanism, and finally the capillary motion is arrested at the top edge of the paper strip by the hydrophobic barrier. The E. coli concentrated at the reaction zone of the paper strip will react with custom formulated chemical reagents to produce a pinkish-red color. Such a color change on the paper strip when dipped into water samples indicates the presence of E. coli contamination in potable water. The performance of the DipTest device has been checked with different known concentrations of E. coli contaminated water samples using different dip and wait times. The DipTest device has also been tested with different interfering bacteria and chemical contaminants. It has been observed that the different interfering contaminants do not have any impact on the DipTest, and it can become a potential solution for screening water samples for E. coli contamination at the point of source.

  13. DipTest: A litmus test for E. coli detection in water

    PubMed Central

    Gunda, Naga Siva Kumar; Dasgupta, Saumyadeb

    2017-01-01

    We have developed a new litmus paper test (DipTest) for detecting Escherichia coli (E. coli) in water samples by performing enzymatic reactions directly on the porous paper substrate. The paper strip consists of a long narrow piece of cellulose blotting paper coated with chemoattractant (at bottom edge), wax hydrophobic barrier (at the top edge), and custom formulated chemical reagents (at reaction zone immediately below the wax hydrophobic barrier). When the paper strip is dipped in water, E. coli in the water sample is attracted toward the paper strip due to a chemotaxic mechanism followed by the ascent along the paper strip toward the reaction zone due to a capillary wicking mechanism, and finally the capillary motion is arrested at the top edge of the paper strip by the hydrophobic barrier. The E. coli concentrated at the reaction zone of the paper strip will react with custom formulated chemical reagents to produce a pinkish-red color. Such a color change on the paper strip when dipped into water samples indicates the presence of E. coli contamination in potable water. The performance of the DipTest device has been checked with different known concentrations of E. coli contaminated water samples using different dip and wait times. The DipTest device has also been tested with different interfering bacteria and chemical contaminants. It has been observed that the different interfering contaminants do not have any impact on the DipTest, and it can become a potential solution for screening water samples for E. coli contamination at the point of source. PMID:28877199

  14. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    PubMed

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  15. Study of electrode pattern design for a CZT-based PET detector.

    PubMed

    Gu, Y; Levin, C S

    2014-06-07

    We are developing a 1 mm resolution small animal positron emission tomography (PET) system using 3D positioning cadmium zinc telluride photon detectors comprising 40 mm × 40 mm × 5 mm crystals metalized with a cross-strip electrode pattern with a 1 mm anode strip pitch. We optimized the electrode pattern design for intrinsic sensitivity and spatial, energy and time resolution performance using a test detector comprising cathode and steering electrode strips of varying dimensions. The study found 3 and 5 mm width cathode strips locate charge-shared photon interactions near cathode strip boundaries with equal precision. 3 mm width cathode strips exhibited large time resolution variability as a function of photon interaction location between the anode and cathode planes (~26 to ~127.5 ns full width at half maximum (FWHM) for 0.5 mm and 4.2 mm depths, respectively). 5 mm width cathode strips by contrast exhibited more stable time resolution for the same interaction locations (~34 to ~83 ns FWHM), provided more linear spatial positioning in the direction orthogonal to the electrode planes, and as much as 68.4% improvement in photon sensitivity over the 3 mm wide cathode strips. The results were understood by analyzing the cathode strips' weighting functions, which indicated a stronger 'small pixel' effect in the 3 mm wide cathode strips. Photon sensitivity and anode energy resolution were seen to improve with decreasing steering electrode bias from 0 to -80 V w.r.t. the anode potential. A slight improvement in energy resolution was seen for wider steering electrode strips (400 versus 100 µm) for charge-shared photon interactions. Although this study successfully focused on electrode pattern features for PET performance, the results are generally applicable to semiconductor photon detectors employing cross-trip electrode patterns.

  16. Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T.

    The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations.more » The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.« less

  17. Evaluation of paper gradient concentration strips for antifungal combination testing of Candida spp.

    PubMed

    Siopi, Maria; Siafakas, Nikolaos; Zerva, Loukia; Meletiadis, Joseph

    2015-11-01

    In vitro combination testing with broth microdilution chequerboard (CHEQ) method is widely used although it is time-consuming, cumbersome and difficult to apply in routine setting of clinical microbiology laboratory. A new gradient concentration paper strip method, the Liofilchem(®) MIC test strips (MTS), provides an alternative easy and fast method enabling the simultaneous diffusion of both drugs in combination. We therefore tested a polyene+azole and an azole+echinocandin combination against 18 Candida isolates with the CHEQ method based on EUCAST guidelines and the MTS method in research and routine settings. Fractional inhibitory concentration (FIC) indices were calculated after 24 and 48 h of incubation based on complete and prominent (FIC-2) growth inhibition endpoints. Reproducibility and agreement within 1 twofold dilution was assessed. The FICs of the two methods were correlated quantitatively with t-test and Pearson analysis and qualitatively with Chi-squared test. The reproducibility of the CHEQ and MTS method was 88-100% and their agreement was 80% with 62-77% of MTS FICs being higher than the corresponding CHEQ FICs. A statistically significant Pearson correlation (r = 0.86, P = 0.0003) and association (χ(2) = 17.05, df = 4, P = 0.002) was found between MTS FIC and CHEQ FIC-2 after 24 h. Categorical agreement was 63% with no very major or major errors. All MTS synergistic interactions were also synergistic with the CHEQ method. © 2015 Blackwell Verlag GmbH.

  18. Development of a colloidal gold immunochromatographic test strip for detection of lymphocystis disease virus in fish.

    PubMed

    Sheng, X Z; Song, J L; Zhan, W B

    2012-10-01

    To develop a gold immunochromatographic test strip for on-site rapid detection of lymphocystis disease virus (LCDV). Monodispersional colloidal gold and gold-labelled anti-LCDV monoclonal antibody (McAb) 2D11 were prepared and characterized by UV-visible spectroscopy and transmission electron microscopy. Gold-labelled probe was used as the detection antibody, and goat anti-mouse IgG at the control line and anti-LCDV McAb 1A8 at the test line of the test strip served as the capture antibody. The positive results could be easily judged by the presence of a red test line with naked eye within 10 min. The test strip, in good agreement with enzyme-linked immunosorbent assay and dot-blotting in sensitivity and LCDV detection, gave a detection limit of 1 μg ml(-1) of LCDV and was stable for 6 months at room temperature and 12 months at 4°C. The test strip was specific, simple and convenient for rapid detection of LCDV presenting good stability and reproducibility. This ready-to-use test strip allows on-site rapid detection of LCDV in fish without the requirement of specialized equipments and professional personnel, which could augment the practical application for diagnosis of LCDV even in disadvantage areas. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  19. Dry reagent dipstick test combined with 23S rRNA PCR for molecular diagnosis of bacterial infection in arthroplasty.

    PubMed

    Kalogianni, Despina P; Goura, Sophia; Aletras, Alexios J; Christopoulos, Theodore K; Chanos, Michalis G; Christofidou, Myrto; Skoutelis, Athanasios; Ioannou, Penelope C; Panagiotopoulos, Elias

    2007-02-15

    Periprosthetic joint infections present a challenging problem in orthopaedics. Conventional methods for detection of arthroplasty infections rely on bacterial culture of synovial fluid aspirates. During recent years, however, molecular tests that are based on DNA amplification by the polymerase chain reaction (PCR), followed by electrophoretic analysis of the products, have been introduced. We report a simple and inexpensive assay that allows visual detection and confirmation of the PCR-amplified sequences by hybridization within minutes. The assay is performed in a dry reagent dipstick format (strip) and does not require special instrumentation. Universal primers are used for PCR of the 23S ribosomal RNA (rRNA) gene. The biotinylated amplification product is hybridized with dA-tailed probes that are specific for six pathogens commonly involved in periprosthetic joint infections. The mixture is applied to the strip, which is then immersed in the appropriate buffer. The buffer migrates along the strip by capillary action and rehydrates gold nanoparticles with oligo(dT) strands attached to their surface. The nanoparticles bind to the target DNA through hybridization, and the hybrids are captured by immobilized streptavidin at the test zone of the strip, producing a characteristic red line. Unbound nanoparticles are captured by immobilized oligo(dT) strands at the control zone of the strip, generating a second line. The dipstick test was applied to the detection of Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Enterococcus faesium, and Haemophilus influenza. Twelve samples of synovial fluids from patients were analyzed for the detection and identification of the infection caused by the six pathogens. The results were compared with bacterial cultures.

  20. Simultaneous detection of dual biomarkers from humans exposed to organophosphorus pesticides by combination of immunochromatographic test strip and ellman assay.

    PubMed

    Yang, Mingming; Zhao, Yuting; Wang, Limin; Paulsen, Michael; Simpson, Christopher D; Liu, Fengquan; Du, Dan; Lin, Yuehe

    2018-05-01

    A novel sandwich immunoassay based immunochromatographic test strip (ICTS) has been developed for simultaneously measuring both butyrylcholinesterase (BChE) activity and the total amount of BChE (including inhibited and active enzyme) from 70 μLpost-exposure human plasma sample. The principle of this method is based on the BChE monoclonal antibody (MAb) capable of acting as both capture antibody and detection antibody. The BChE MAb which was immobilized on the test line was able to recognize both organophosphorus BChE adducts (OP-BChE) and BChE and provided equal binding affinity, permitting detection of the total enzyme amount in post-exposure human plasma samples. The formed immunocomplexes on the test line can further be excised from the test-strip for subsequent off-line measurement of BChE activity using the Ellman assay. Therefore, dual biomarkers of BChE activity and phosphorylation (OP-BChE) will be obtained simultaneously. The whole sandwich-immunoassay was performed on one ICTS, greatly reducing analytical time. The ICTS sensor showed excellent linear responses for assaying total amount of BChE and active BChE ranging from 0.22 to 3.58nM and 0.22-7.17nM, respectively. Both the signal detection limits are 0.10nM. We validated the practical application of the proposed method to measure 124 human plasma samples from orchard workers and cotton farmers with long-term exposure to organophosphorus pesticides (OPs). The results were in highly agreement with LC/MS/MS which verified our method is extremely accurate. Combining the portability and rapidity of test strip and the compatibility of BChE MAb as both capture antibody and detection antibody, the developed method provides a baseline-free, low-cost and rapid tool for in-field monitoring of OP exposures. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Characteristics of laminates with delamination control strips

    NASA Technical Reports Server (NTRS)

    Sun, C. T.; Goering, J. C.; Alper, J. M.; Gause, L. W.

    1992-01-01

    Tough resin is needed to resist delamination crack propagation. However, modulus often has to be compromised because it is difficult to retain both high modulus and toughness in a matrix material. A potential solution is to use a hybrid system in which tough resin strips are included within a conventional matrix composite. By adjusting the spacing of the tough resin strips, maximum delamination size can be controlled. Experimental results for impact damage and subsequent damage propagation in laminates containing tough resin strips are reported. Plain adhesive strips and fiber-reinforced tough resin composite strips were used in constructing the hybrid laminates. Test results indicated that size of delamination inflicted by impact was confined between the tough resin strips. As a result, significantly increased residual compressive strength was obtained. Impacted laminates containing tough resin strips were also fatigue tested. It was found that these strips reduced the growth of the impact damage area relative to the growth seen in coupons with no tough resin strips. Damage growth from an open hole under tension fatigue was evaluated using both tough resin strips and glass fiber reinforced tough resin strips. Unreinforced tough resin strips retarded delamination growth from the open hole, but did not stop matrix cracks growing in the fiber direction. Fiber reinforced tough resin strips did not contain axial delamination growth from the open hole. However, they did act as crack arresters, stopping the through-the-thickness tension crack originating from the hole.

  2. Stripping potential of bituminous concrete.

    DOT National Transportation Integrated Search

    1978-01-01

    Laboratory data were gathered with a newly developed stripping test in anticipation that the test would be adopted for use by the Department. In addition to providing experience in the performance of the test and interpretation of test results, the i...

  3. Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes

    PubMed Central

    Cho, Seon; Kim, Suyoung; Cho, Han-Ik

    2017-01-01

    Background Albuminuria is generally known as a sensitive marker of renal and cardiovascular dysfunction. It can be used to help predict the occurrence of nephropathy and cardiovascular disorders in diabetes. Individuals with prediabetes have a tendency to develop macrovascular and microvascular pathology, resulting in an increased risk of retinopathy, cardiovascular diseases, and chronic renal diseases. We evaluated the clinical value of a strip test for measuring the urinary albumin-to-creatinine ratio (ACR) in prediabetes and diabetes. Methods Spot urine samples were obtained from 226 prediabetic and 275 diabetic subjects during regular health checkups. Urinary ACR was measured by using strip and laboratory quantitative tests. Results The positive rates of albuminuria measured by using the ACR strip test were 15.5% (microalbuminuria, 14.6%; macroalbuminuria, 0.9%) and 30.5% (microalbuminuria, 25.1%; macroalbuminuria, 5.5%) in prediabetes and diabetes, respectively. In the prediabetic population, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of the ACR strip method were 92.0%, 94.0%, 65.7%, 99.0%, and 93.8%, respectively; the corresponding values in the diabetic population were 80.0%, 91.6%, 81.0%, 91.1%, and 88.0%, respectively. The median [interquartile range] ACR values in the strip tests for measurement ranges of <30, 30-300, and >300 mg/g were 9.4 [6.3-15.4], 46.9 [26.5-87.7], and 368.8 [296.2-575.2] mg/g, respectively, using the laboratory method. Conclusions The ACR strip test showed high sensitivity, specificity, and negative predictive value, suggesting that the test can be used to screen for albuminuria in cases of prediabetes and diabetes. PMID:27834062

  4. Weld leaks rapidly and safely detected

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Test method detects leaks that occur during hydrostatic pressure testing of welded joints in metal tanks. A strip of aluminum foil and a strip of water-soluble paper are placed over the weld. A voltage applied between the tank wall and the foil strip is monitored to detect a decrease in ohmic resistance caused by water leakage into the paper layer.

  5. Research on Modeling of Propeller in a Turboprop Engine

    NASA Astrophysics Data System (ADS)

    Huang, Jiaqin; Huang, Xianghua; Zhang, Tianhong

    2015-05-01

    In the simulation of engine-propeller integrated control system for a turboprop aircraft, a real-time propeller model with high-accuracy is required. A study is conducted to compare the real-time and precision performance of propeller models based on strip theory and lifting surface theory. The emphasis in modeling by strip theory is focused on three points as follows: First, FLUENT is adopted to calculate the lift and drag coefficients of the propeller. Next, a method to calculate the induced velocity which occurs in the ground rig test is presented. Finally, an approximate method is proposed to obtain the downwash angle of the propeller when the conventional algorithm has no solution. An advanced approximation of the velocities induced by helical horseshoe vortices is applied in the model based on lifting surface theory. This approximate method will reduce computing time and remain good accuracy. Comparison between the two modeling techniques shows that the model based on strip theory which owns more advantage on both real-time and high-accuracy can meet the requirement.

  6. Study of electrode pattern design for a CZT-based PET detector

    PubMed Central

    Gu, Y; Levin, C S

    2014-01-01

    We are developing a 1 mm resolution small animal positron emission tomography (PET) system using 3-D positioning Cadmium Zinc Telluride (CZT) photon detectors comprising 40 mm × 40 mm × 5 mm crystals metalized with a cross-strip electrode pattern with a 1 mm anode strip pitch. We optimized the electrode pattern design for intrinsic sensitivity and spatial, energy and time resolution performance using a test detector comprising cathode and steering electrode strips of varying dimensions. The study found 3 mm and 5 mm width cathode strips locate charge-shared photon interactions near cathode strip boundaries with equal precision. 3 mm width cathode strips exhibited large time resolution variability as a function of photon interaction location between the anode and cathode planes (~26 ns to ~127.5 ns FWHM for 0.5 mm and 4.2 mm depths, respectively). 5 mm width cathode strips by contrast exhibited more stable time resolution for the same interaction locations (~34 ns to ~83 ns FWHM), provided more linear spatial positioning in the direction orthogonal to the electrode planes, and as much as 68.4% improvement in photon sensitivity over the 3 mm wide cathode strips. The results were understood by analyzing the cathode strips’ weighting functions, which indicated a stronger “small pixel” effect in the 3 mm wide cathode strips. Photon sensitivity and anode energy resolution were seen to improve with decreasing steering electrode bias from 0 V to −80 V w.r.t the anode potential. A slight improvement in energy resolution was seen for wider steering electrode strips (400 μm vs. 100 μm) for charge-shared photon interactions. Although this study successfully focused on electrode pattern features for PET performance, the results are generally applicable to semiconductor photon detectors employing cross-trip electrode patterns. PMID:24786208

  7. The preprocessed connectomes project repository of manually corrected skull-stripped T1-weighted anatomical MRI data.

    PubMed

    Puccio, Benjamin; Pooley, James P; Pellman, John S; Taverna, Elise C; Craddock, R Cameron

    2016-10-25

    Skull-stripping is the procedure of removing non-brain tissue from anatomical MRI data. This procedure can be useful for calculating brain volume and for improving the quality of other image processing steps. Developing new skull-stripping algorithms and evaluating their performance requires gold standard data from a variety of different scanners and acquisition methods. We complement existing repositories with manually corrected brain masks for 125 T1-weighted anatomical scans from the Nathan Kline Institute Enhanced Rockland Sample Neurofeedback Study. Skull-stripped images were obtained using a semi-automated procedure that involved skull-stripping the data using the brain extraction based on nonlocal segmentation technique (BEaST) software, and manually correcting the worst results. Corrected brain masks were added into the BEaST library and the procedure was repeated until acceptable brain masks were available for all images. In total, 85 of the skull-stripped images were hand-edited and 40 were deemed to not need editing. The results are brain masks for the 125 images along with a BEaST library for automatically skull-stripping other data. Skull-stripped anatomical images from the Neurofeedback sample are available for download from the Preprocessed Connectomes Project. The resulting brain masks can be used by researchers to improve preprocessing of the Neurofeedback data, as training and testing data for developing new skull-stripping algorithms, and for evaluating the impact on other aspects of MRI preprocessing. We have illustrated the utility of these data as a reference for comparing various automatic methods and evaluated the performance of the newly created library on independent data.

  8. Hydrometallurgical recovery of germanium from coal gasification fly ash: pilot plant scale evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arroyo, F.; Fernandez-Pereira, C.; Olivares, J.

    2009-04-15

    In this article, a hydrometallurgical method for the selective recovery of germanium from fly ash (FA) has been tested at pilot plant scale. The pilot plant flowsheet comprised a first stage of water leaching of FA, and a subsequent selective recovery of the germanium from the leachate by solvent extraction method. The solvent extraction method was based on Ge complexation with catechol in an aqueous solution followed by the extraction of the Ge-catechol complex (Ge(C{sub 6}H{sub 4}O{sub 2}){sub 3}{sup 2-}) with an extracting organic reagent (trioctylamine) diluted in an organic solvent (kerosene), followed by the subsequent stripping of the organicmore » extract. The process has been tested on a FA generated in an integrated gasification with combined cycle (IGCC) process. The paper describes the designed 5 kg/h pilot plant and the tests performed on it. Under the operational conditions tested, approximately 50% of germanium could be recovered from FA after a water extraction at room temperature. Regarding the solvent extraction method, the best operational conditions for obtaining a concentrated germanium-bearing solution practically free of impurities were as follows: extraction time equal to 20 min; aqueous phase/organic phase volumetric ratio equal to 5; stripping with 1 M NaOH, stripping time equal to 30 min, and stripping phase/organic phase volumetric ratio equal to 5. 95% of germanium were recovered from water leachates using those conditions.« less

  9. [Efficacy of a rapid test to diagnose Plasmodium vivax in symptomatic patients of Chiapas, Mexico].

    PubMed

    González-Cerón, Lilia; Rodríguez, Mario H; Betanzos, Angel F; Abadía, Acatl

    2005-01-01

    To evaluate, under laboratory conditions, the sensitivity and specificity of a rapid diagnostic test (OptiMAL), based on immunoreactive strips, to detect Plasmodium vivax infection in febrile patients in Southern Chiapas, Mexico. The presence of parasites in blood samples of 893 patients was investigated by Giemsa-stained thick blood smear microscopic examination (gold standard). A blood drop from the same sample was smeared on immunoreactive strips to investigate the presence of the parasite pLDH. Discordant results were resolved by PCR amplification of the parasite's 18S SSU rRNA, to discard infection. OptiMAL had an overall sensitivity of 93.3% and its specificity was 99.5%. Its positive and negative predictive values were 96.5% and 98.9%, respectively. Signal intensity in OptiMAL strips correlated well with the parasitemia density in the blood samples (r = 0.601, p = 0.0001). This rapid test had acceptable sensitivity and specificity to detect P. vivax under laboratory conditions and could be useful for malaria diagnosis in field operations in Mexico.

  10. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis.

    PubMed

    Wang, Du; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2016-07-14

    Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.

  11. Development of an immunochromatographic test with anti-LipL32-coupled gold nanoparticles for Leptospira detection.

    PubMed

    Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai

    2014-04-01

    Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.

  12. Effects of a Novel Whitening Formulation on Dental Enamel.

    PubMed

    Takesh, Thair; Sargsyan, Anik; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-04-01

    The goal of this study was to evaluate the enamel whitening effects of 2 new test formulations, one of which was a rinse, and the other a whitening strip. Forty enamel chips were prepared from 20 healthy extracted teeth (2 from each tooth). After pre-staining and colorimetry to measure L* and b* values, 20 matched samples were immersed in either test or control rinses, and then colorimetry was performed again after 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr and 48 hrs (Each hour equates to one month of clinical use at the recommended dosage of 1 minute exposure 2 times a day). The remaining 20 matched samples were exposed to the test or control whitening strips and colorimetry was performed every 30 minutes for a total of 10 treatments. Overall, the whitening performance of test and control strips was similar. The test and control rinses had a similar lightening effect over the first 3 hours (equivalent to 3 months of clinical use). Subsequently, the control rinse continued to lighten samples, whereas the test rinse had little further effect. Test and control-whitening strips showed similar effects; over time whitening strips showed a greater lightening effect than whitening rinses.

  13. Microscopic or occult hematuria, when reflex testing is not good laboratory practice.

    PubMed

    Froom, Paul; Barak, Mira

    2010-01-01

    Consensus opinion suggests that hematuria found by dipstick and not confirmed on microscopic examination (<2 erythrocytes per high power field) signifies a false-positive reagent strip test result. Standard practice is to repeat the dipstick test several days later and if still positive to confirm by microscopic examination. If discordant results are obtained, experts recommend reflex testing for urinary myoglobin and hemoglobin concentrations. The question is whether or not this approach represents good laboratory practice. These recommendations are not evidence based. We conclude that the reference range for red blood cells on the reagent strip should be increased to 25x10(6) cells/L for young men, and 50x10(6) cells/L for the rest of the adult population, ranges consistent with flow cytometry reports. Confirmation reflex testing using tests that have inferior sensitivity, precision and probably accuracy is not recommended.

  14. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    PubMed

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  15. Experimental Investigations on the Pull-Out Behavior of Tire Strips Reinforced Sands.

    PubMed

    Li, Li-Hua; Chen, Yan-Jun; Ferreira, Pedro Miguel Vaz; Liu, Yong; Xiao, Heng-Lin

    2017-06-27

    Waste tires have excellent mechanical performance and have been used as reinforcing material in geotechnical engineering; however, their interface properties are poorly understood. To further our knowledge, this paper examines the pull-out characteristics of waste tire strips in a compacted sand, together with uniaxial and biaxial geogrids also tested under the same conditions. The analysis of the results shows that the interlocking effect and pull-out resistance between the tire strip and the sand is very strong and significantly higher than that of the geogrids. In the early stages of the pull-out test, the resistance is mainly provided by the front portion of the embedded tire strips, as the pull-out test continues, more and more of the areas towards the end of the tire strips are mobilized, showing a progressive failure mechanism. The deformations are proportional to the frictional resistance between the tire-sand interface, and increase as the normal stresses increase. Tire strips of different wear intensities were tested and presented different pull-out resistances; however, the pull-out resistance mobilization patterns were generally similar. The pull-out resistance values obtained show that rubber reinforcement can provide much higher pull-out forces than the geogrid reinforcements tested here, showing that waste tires are an excellent alternative as a reinforcing system, regardless of the environmental advantages.

  16. Development of a lateral flow colloidal gold immunoassay strip for the rapid detection of enrofloxacin residues.

    PubMed

    Zhao, Yinli; Zhang, Gaiping; Liu, Qingtang; Teng, Man; Yang, Jifei; Wang, Jianhua

    2008-12-24

    A rapid immunochromatographic lateral flow test strip of competitive format has been developed using a gold-conjugated monoclonal antibody for the specific determination of enrofloxacin (ENR) residues in chicken muscles. For this purpose, a specific monoclonal antibody (mAb) for ENR was generated and characterized. The mAb showed negligible cross-reactivity with other related compounds. Using ENR standards prepared in chicken muscle extracts from 0 to 24.3 ng/mL (microg/kg), the method indicated that the detection limit of the test strip, as measured in a strip scanner, was as low as 0.138 microg/kg of ENR and the half-maximal inhibition concentration (IC(50)) was 0.935 microg/kg. For samples spiked at 10, 20, and 30 microg/kg, the recovery was between 85.3 and 96.1% and the coefficient of variation [CV (%)] was between 4.5 and 7.91%. Parallel analysis of muscle samples from chickens fed ENR showed good comparable results obtained from the test strip and LC-MS. Each test requires 5-10 min. The data indicate that the method has high sensitivity, specificity, and the advantages of simplicity and speed of performance. Therefore, the test strip provides a useful screening method for quantitative, semiquantitative, or qualitative detection of ENR residues in chicken muscles.

  17. On-Site Classification of Pansteatitis in Mozambique Tilapia (Oreochromis mossambicus) using a Portable Lipid-Based Analyzer

    PubMed Central

    Somerville, Stephen E.; Cantu, Theresa M.; Guillette, Matthew P.; Botha, Hannes; Boggs, Ashley S. P.; Luus-Powell, Wilmien; Guillette, Louis J.

    2017-01-01

    While no pansteatitis-related large-scale mortality events have occurred since 2008, the current status of pansteatitis (presence and pervasiveness) in the Olifants River system and other regions of South Africa remain largely unknown. In part, this is due to both a lack of known biological markers of pansteatitis and a lack of suitable non-invasive assays capable of rapidly classifying the disease. Here, we propose the application of a point-of-care (POC) device using lipid-based test strips (total cholesterol (TC) and total triglyceride (TG)), for classifying pansteatitis status in the whole blood of pre-spawning Mozambique tilapia (Oreochromis mossambicus). Using the TC strips, the POC device was able to non-lethally classify the tilapia as either healthy or pansteatitis-affected; the sexes were examined independently because sexual dimorphism was observed for TC (males p = 0.0364, females χ2 = 0.0007). No significant difference between diseased and pansteatitis-affected tilapia was observed using the TG strips. This is one of the first described applications of using POC devices for on-site environmental disease state testing. A discussion on the merits of using portable lipid-based analyzers as an in-field disease-state diagnostic tool is provided. PMID:28729886

  18. Simple, Rapid, and Highly Sensitive Detection of Diphosgene and Triphosgene by Spectrophotometric Methods

    PubMed Central

    Joy, Abraham; Anim-Danso, Emmanuel; Kohn, Joachim

    2009-01-01

    Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ~ 4 µmol/L by UV and <0.4 µmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test strip is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(Bisphenol A carbonate). PMID:19782219

  19. Development of an immunochromatographic kit for rapid detection of human influenza B virus infection.

    PubMed

    Zhang, Peirui; Duan, Yueqiang; Zhang, Dexi; Zhang, Shaogeng; Li, Zhiwei; Wang, Xiliang; Yang, Penghui

    2014-01-01

    Type B influenza virus is a major epidemic strain responsible for considerable mortality and morbidity. A colloidal gold immunochromatographic strip for the rapid detection of human influenza B virus was developed. This test is based on membrane chromatography and uses colloidal gold conjugated with influenza B virus anti-NP monoclonal antibody as the tracer. The assembled test strip was housed in a plastic case. The colloid gold strip (CGS) specifically detected all influenza B viruses tested and did not react with other respiratory viruses. Compared with SYBR Green real-time PCR, the sensitivity and specificity of the CGS test was 89.76% and 99.56%, respectively, and the consistency ratio between CGS and real-time PCR was 96.06% in detecting influenza B virus in 710 nasopharyngeal swabs from patients with influenza-like illness in the hospital. The CGS array developed in this study enabled typing of influenza B viruses in human clinical specimens. Thus, together with the advantages of rapid detection and easy operation without requiring specialized personnel and equipment, this technique is a convenient and relatively inexpensive diagnostic tool for large-scale screening of clinical samples.

  20. The effects of size and synthesis methods of gold nanoparticle-conjugated MαHIgG4 for use in an immunochromatographic strip test to detect brugian filariasis

    NASA Astrophysics Data System (ADS)

    Rabizah Makhsin, Siti; Razak, Khairunisak Abdul; Noordin, Rahmah; Dyana Zakaria, Nor; Chun, Tan Soo

    2012-12-01

    This study describes the properties of colloidal gold nanoparticles (AuNPs) with sizes of 20, 30 and 40 nm, which were synthesized using citrate reduction or seeding-growth methods. Likewise, the conjugation of these AuNPs to mouse anti-human IgG4 (MαHIgG4) was evaluated for an immunochromatographic (ICG) strip test to detect brugian filariasis. The morphology of the AuNPs was studied based on the degree of ellipticity (G) of the transmission electron microscopy images. The AuNPs produced using the seeding-growth method showed lower ellipticity (G ≤ 1.11) as compared with the AuNPs synthesized using the citrate reduction method (G ≤ 1.18). Zetasizer analysis showed that the AuNPs that were synthesized using the seeding-growth method were almost monodispersed with a lower polydispersity index (PDI; PDI≤0.079), as compared with the AuNPs synthesized using the citrate reduction method (PDI≤0.177). UV-visible spectroscopic analysis showed a red-shift of the absorbance spectra after the reaction with MαHIgG4, which indicated that the AuNPs were successfully conjugated. The optimum concentration of the BmR1 recombinant antigen that was immobilized on the surface of the ICG strip on the test line was 1.0 mg ml-1. When used with the ICG test strip assay and brugian filariasis serum samples, the conjugated AuNPs-MαHIgG4 synthesized using the seeding-growth method had faster detection times, as compared with the AuNPs synthesized using the citrate reduction method. The 30 nm AuNPs-MαHIgG4, with an optical density of 4 from the seeding-growth method, demonstrated the best performance for labelling ICG strips because it displayed the best sensitivity and the highest specificity when tested with serum samples from brugian filariasis patients and controls.

  1. The effects of size and synthesis methods of gold nanoparticle-conjugated MαHIgG4 for use in an immunochromatographic strip test to detect brugian filariasis.

    PubMed

    Makhsin, Siti Rabizah; Razak, Khairunisak Abdul; Noordin, Rahmah; Zakaria, Nor Dyana; Chun, Tan Soo

    2012-12-14

    This study describes the properties of colloidal gold nanoparticles (AuNPs) with sizes of 20, 30 and 40 nm, which were synthesized using citrate reduction or seeding-growth methods. Likewise, the conjugation of these AuNPs to mouse anti-human IgG(4) (MαHIgG(4)) was evaluated for an immunochromatographic (ICG) strip test to detect brugian filariasis. The morphology of the AuNPs was studied based on the degree of ellipticity (G) of the transmission electron microscopy images. The AuNPs produced using the seeding-growth method showed lower ellipticity (G ≤ 1.11) as compared with the AuNPs synthesized using the citrate reduction method (G ≤ 1.18). Zetasizer analysis showed that the AuNPs that were synthesized using the seeding-growth method were almost monodispersed with a lower polydispersity index (PDI; PDI≤0.079), as compared with the AuNPs synthesized using the citrate reduction method (PDI≤0.177). UV-visible spectroscopic analysis showed a red-shift of the absorbance spectra after the reaction with MαHIgG(4), which indicated that the AuNPs were successfully conjugated. The optimum concentration of the BmR1 recombinant antigen that was immobilized on the surface of the ICG strip on the test line was 1.0 mg ml(-1). When used with the ICG test strip assay and brugian filariasis serum samples, the conjugated AuNPs-MαHIgG(4) synthesized using the seeding-growth method had faster detection times, as compared with the AuNPs synthesized using the citrate reduction method. The 30 nm AuNPs-MαHIgG(4), with an optical density of 4 from the seeding-growth method, demonstrated the best performance for labelling ICG strips because it displayed the best sensitivity and the highest specificity when tested with serum samples from brugian filariasis patients and controls.

  2. Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs) measured 12.5, exceeding the required value of 8. This value is consistent with resultsmore » from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs) results.« less

  3. Development of a multiplex lateral flow strip test for foot-and-mouth disease virus detection using monoclonal antibodies.

    PubMed

    Yang, Ming; Caterer, Nigel R; Xu, Wanhong; Goolia, Melissa

    2015-09-01

    Foot-and-mouth disease (FMD) is one of the world's most highly contagious animal diseases with tremendous economic consequences. A rapid and specific test for FMD diagnosis at the site of a suspected outbreak is crucial for the implementation of control measures. This project developed a multiplex lateral flow immunochromatographic strip test (multiplex-LFI) for the rapid detection and serotyping of FMD viruses. The monoclonal antibodies (mAbs) against serotypes O, A, and Asia 1 were used as capture mAbs. The mAbs were conjugated with fluorescein, rhodamine or biotin for serotype O, A and Asia 1, respectively. The detection mAbs which consisted of a serotype-independent mAb in combination with one serotype A-specific mAb and one Asia 1-specific mAb, were each colloidal gold-conjugated. The strips used in this study contained one control line and three test lines, which corresponded to one of the three serotypes, O, A or Asia 1. The newly developed multiplex-LFI strip test specifically identified serotype O (n=46), A (n=45) and Asia 1 (n=17) in all tested field isolates. The sensitivity of this strip test was comparable to the double antibody sandwich ELISA for serotypes O and A, but lower than the ELISA for serotype Asia 1. The multiplex-LFI strip test identified all tissue suspensions from animals that were experimentally inoculated with serotypes O, A or Asia 1. FMD viruses were detected in 38% and 50% of the swab samples from the lesion areas of experimentally inoculated sheep for serotypes O and A, respectively. The capability of the multiplex-LFI strip tests to produce rapid results with high specificity for FMD viruses of multiple serotypes makes this test a valuable tool to detect FMD viruses at outbreak sites. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  4. [USING URINARY STRIPS].

    PubMed

    Barbeito García, Ana; Sampayo Montenegro, Ana

    2015-10-01

    Urinalysis using reactive strip is a commonly used in clinical practice. Although mainly indicated as first step test when a urine infection it suspected, it may also be a helpful tool in the management of a wide range of disorders. Standard urine test strips may comprise of up to 10 different chemical pads or reagents (leukocytes, nitrites, pH, glucose, proteins, ketones, bilirubin, urobilinogen, density and blood) that allow a qualitative and semiquantitative analysis of a urine sample. The test method consists of immersing the strip completely in a well-mixed sample of urine and left to stand for the time necessary for the reactions to occur (which is variable depending on the manufacturer). Finally the colors that appear are compared against a specific chromatic scale provided. Several factors may influence the results causing a significant number of false positives and negatives. Such limitations should always be taken into account when reading the test. Despite clinical features lead to the suspicion of an infection, urine test strips is a fast screening test that may reinforce the diagnosis. The combination of dysuria, frequency and emergency, hematuria, pain and sensibility in the pelvis reaches a positive predictive value to identified a urine infection of 90 %. When only dysuria and emergency or high frequency are present, the such probability diminishes to 70-80%, and, when dysuria is the only symptom, it drops to 25%. Despite urine test strips is a fast, easy and cheap method for the diagnosis and follow-up of several diseases, results are fairly heterogeneous and may be influenced by external factors. Therefore a cautious interpretation if advised. Sensibility and specificity of urine test strips is widely variable (S 46%-86% and E 17%-93%). Although the highest diagnostic values are obtained at primary care centers, where such tests are routinely used in a diverse population, the number of false positives is still high. This issue should be taken into account and a proper differential diagnosis of a positive result is mandatory in all cases. More studies are needed to assess the real sensibility and specificity of urinary reactive strips.

  5. Accuracy, Precision, Ease-Of-Use, and Cost of Methods to Test Ebola-Relevant Chlorine Solutions

    PubMed Central

    Wells, Emma; Wolfe, Marlene K.; Murray, Anna; Lantagne, Daniele

    2016-01-01

    To prevent transmission in Ebola Virus Disease (EVD) outbreaks, it is recommended to disinfect living things (hands and people) with 0.05% chlorine solution and non-living things (surfaces, personal protective equipment, dead bodies) with 0.5% chlorine solution. In the current West African EVD outbreak, these solutions (manufactured from calcium hypochlorite (HTH), sodium dichloroisocyanurate (NaDCC), and sodium hypochlorite (NaOCl)) have been widely used in both Ebola Treatment Unit and community settings. To ensure solution quality, testing is necessary, however test method appropriateness for these Ebola-relevant concentrations has not previously been evaluated. We identified fourteen commercially-available methods to test Ebola-relevant chlorine solution concentrations, including two titration methods, four DPD dilution methods, and six test strips. We assessed these methods by: 1) determining accuracy and precision by measuring in quintuplicate five different 0.05% and 0.5% chlorine solutions manufactured from NaDCC, HTH, and NaOCl; 2) conducting volunteer testing to assess ease-of-use; and, 3) determining costs. Accuracy was greatest in titration methods (reference-12.4% error compared to reference method), then DPD dilution methods (2.4–19% error), then test strips (5.2–48% error); precision followed this same trend. Two methods had an accuracy of <10% error across all five chlorine solutions with good precision: Hach digital titration for 0.05% and 0.5% solutions (recommended for contexts with trained personnel and financial resources), and Serim test strips for 0.05% solutions (recommended for contexts where rapid, inexpensive, and low-training burden testing is needed). Measurement error from test methods not including pH adjustment varied significantly across the five chlorine solutions, which had pH values 5–11. Volunteers found test strip easiest and titration hardest; costs per 100 tests were $14–37 for test strips and $33–609 for titration. Given the ease-of-use and cost benefits of test strips, we recommend further development of test strips robust to pH variation and appropriate for Ebola-relevant chlorine solution concentrations. PMID:27243817

  6. Physical and mechanical properties of flakeboard reinforced with bamboo strips

    Treesearch

    Ge Wang; Zhehui Jiang; Chung Y. Hse; Todd F. Shupe

    2009-01-01

    The objective of this study was to investigate the physical and mechanical performance of flakeboard reinforced with bamboo strips. The study investigated three different bamboo strip alignment patterns and an experimental control. All panels were tested in static bending both along parallel and perpendicular to the lengths of the bamboo strips. Internal bond...

  7. Predicting moisture-induced damage to asphaltic concrete : field evaluation : final report.

    DOT National Transportation Integrated Search

    1981-01-01

    Virginia was one of seven agencies that participated in the evaluation of a stripping test developed under National Cooperative Highway Research Program Project 4-8(3). The test was used to predict stripping of a field test section and the test resul...

  8. Development of a nanogold-based immunochromatographic assay for detection of morphine in urine using the Amor-HK16 monoclonal antibody.

    PubMed

    Dehghannezhad, Ardeshir; Paknejad, Maliheh; Rasaee, Mohammad Javad; Omidfar, Kobra; Seyyed Ebrahimi, Shadi Sadat; Ghahremani, Hossein

    2012-12-01

    A simple, rapid competitive immunochromatography (ICG) strip test was developed to detect morphine in urine samples using a monoclonal antibody produced in-house and conjugated to gold nanoparticles. Hybridoma cells were cultured and the Amor-HK16 monoclonal antibody against morphine was obtained from the supernatant after purification by salting out and passing through a Protein G-Agarose affinity column. Morphine was obtained from morphine sulfate and a C6-hemisuccinate derivative of morphine was prepared, conjugated to bovine serum albumin, and immobilized to a nitrocellulose membrane as the test line. Goat anti-mouse antibody was used as a binder in the control line in the detection zone of the strip. Colloidal gold particles of diameter approximately 20 nm were prepared and conjugated to the monoclonal antibody. The detection limit of the test strip was found to be 2000 ng/mL of morphine in urine samples. Reliability was determined by performing the ICG test on 103 urine samples and comparing the results with those obtained by thin-layer chromatography. The sensitivity of the test was 100%, and the analysis time for the assay was approximately 5 min. The new ICG method was adequately sensitive and accurate for the rapid screening of morphine in urine.

  9. Robotic Laser Coating Removal System

    DTIC Science & Technology

    2008-07-01

    Materiel Command IRR Internal Rate of Return JTP Joint Test Protocol JTR Joint Test Report LARPS Large Area Robotic Paint Stripping LASER Light...use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air Force...The use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air

  10. [The Application of Gold-immunochromatographic Test Strip Reader in Serum Antibody Detection in Echinococcosis].

    PubMed

    Xie, Gui-lin; Yin, Jun-xia; Duan, Xin-yu; Feng, Xiao-hui; Wang, Yang; Jiang, Kai; Chen, Xin-mei

    2015-06-01

    One hundred and fifty-nine serum samples from hydatid disease patients and 80 serum samples from patients with other liver diseases were detected by gold-immunochromatographic assay, and read by naked eyes and the gold-immunochromatographic test strip reader. The sensitivity, specificity, and accuracy of eye-based method was 92.4% (147/159), 85.0% (68/80), and 89.9% (215/239), which was lower than that of the reader detection (95.6%, 93.7%, 95.0%, respectively). While, its false negative rate (7.5%, 12/159) and false positive rate (15.0%, 12/80) was higher than that of the reader detection (4.4% and 6.3%, respectively).

  11. Bismuth-based electrochemical stripping analysis

    DOEpatents

    Wang, Joseph

    2004-01-27

    Method and apparatus for trace metal detection and analysis using bismuth-coated electrodes and electrochemical stripping analysis. Both anodic stripping voltammetry and adsorptive stripping analysis may be employed.

  12. Effects of a Novel Whitening Formulation on Dental Enamel

    PubMed Central

    Takesh, Thair; Sargsyan, Anik; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-01-01

    Objective The goal of this study was to evaluate the enamel whitening effects of 2 new test formulations, one of which was a rinse, and the other a whitening strip. Materials and Methods Forty enamel chips were prepared from 20 healthy extracted teeth (2 from each tooth). After pre-staining and colorimetry to measure L* and b* values, 20 matched samples were immersed in either test or control rinses, and then colorimetry was performed again after 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr and 48 hrs (Each hour equates to one month of clinical use at the recommended dosage of 1 minute exposure 2 times a day). The remaining 20 matched samples were exposed to the test or control whitening strips and colorimetry was performed every 30 minutes for a total of 10 treatments. Results Overall, the whitening performance of test and control strips was similar. The test and control rinses had a similar lightening effect over the first 3 hours (equivalent to 3 months of clinical use). Subsequently, the control rinse continued to lighten samples, whereas the test rinse had little further effect. Conclusion Test and control-whitening strips showed similar effects; over time whitening strips showed a greater lightening effect than whitening rinses. PMID:28706755

  13. Experimental Investigations on the Pull-Out Behavior of Tire Strips Reinforced Sands

    PubMed Central

    Li, Li-Hua; Chen, Yan-Jun; Ferreira, Pedro Miguel Vaz; Liu, Yong; Xiao, Heng-Lin

    2017-01-01

    Waste tires have excellent mechanical performance and have been used as reinforcing material in geotechnical engineering; however, their interface properties are poorly understood. To further our knowledge, this paper examines the pull-out characteristics of waste tire strips in a compacted sand, together with uniaxial and biaxial geogrids also tested under the same conditions. The analysis of the results shows that the interlocking effect and pull-out resistance between the tire strip and the sand is very strong and significantly higher than that of the geogrids. In the early stages of the pull-out test, the resistance is mainly provided by the front portion of the embedded tire strips, as the pull-out test continues, more and more of the areas towards the end of the tire strips are mobilized, showing a progressive failure mechanism. The deformations are proportional to the frictional resistance between the tire-sand interface, and increase as the normal stresses increase. Tire strips of different wear intensities were tested and presented different pull-out resistances; however, the pull-out resistance mobilization patterns were generally similar. The pull-out resistance values obtained show that rubber reinforcement can provide much higher pull-out forces than the geogrid reinforcements tested here, showing that waste tires are an excellent alternative as a reinforcing system, regardless of the environmental advantages. PMID:28773069

  14. Evaluation of Reagent-Impregnated Coagulase-Mannitol Test Strip for Speciation of Staphylococci

    PubMed Central

    Washington, John A.; Yu, Pauline K. W.

    1970-01-01

    A new coagulase-mannitol reagent-impregnated strip test has been evaluated with 322 Micrococcaceae. Mannitol fermentation was determined accurately by this test; however, the coagulase reaction was difficult to interpret and was subject to significant error. PMID:5418952

  15. Lowering Cost Share May Improve Rates of Home Glucose Monitoring Among Patients with Diabetes Using Insulin.

    PubMed

    Xie, Yiqiong; Agiro, Abiy; Bowman, Kevin; DeVries, Andrea

    2017-08-01

    Not much is known about the extent to which lower cost share for blood glucose strips is associated with persistent filling. To evaluate the relationship between cost sharing for blood glucose testing strips and continued use of testing strips. This is a retrospective observational study using medical and pharmacy claims data integrated with laboratory hemoglobin A1c (A1c) values for patients using insulin and blood glucose testing strips. Diabetic patients using insulin who had at least 1 fill of blood glucose testing strips between 2010 and 2012 were included. Patients were divided into a low cost-share group (out-of-pocket cost percentage of total testing strip costs over a 1-year period from the initial fill < 20%; n = 3,575) and a high cost-share group (out-of-pocket cost percentage ≥ 20%; n = 3,580). We compared the likelihood of continued testing strip fills after the initial fill between the 2 groups by using modified Poisson regression models. Patients with low cost share had higher rates of continued testing strip fills compared with those with high cost share (89% vs. 82%, P < 0.001). Lower cost share was associated with greater probability of continued fills (adjusted risk ratio [aRR] = 1.05, 95% CI = 1.03-1.07, P < 0.001). Other patient characteristics associated with continued fills included type 1 diabetes diagnosis, types of insulin regimens, and health insurance plan type. In a subset analysis of patients whose A1c values at baseline were above the target level (8%) set by the National Committee for Quality Assurance guidelines, we saw a slight increase in magnitude of relationship between cost share and continued fills (RR = 1.06, 95% CI = 1.03-1.10, P < 0.01). There was a statistically significant association between cost share for testing strips and continued blood glucose self-monitoring. Among patients not achieving A1c control at baseline, there was an increase in the magnitude of relationship. Lowering cost share for testing strips can remove a barrier to persistence in diabetes self-management. Funding for this study was provided by Anthem, which had no role in the study design, data interpretation, or preparation or review of the manuscript. The decision to publish was strictly that of the authors. Xie, Agiro, and DeVries are employees of HealthCore, a wholly owned subsidiary of Anthem. Bowman is an employee of Anthem. Study concept and design were contributed by all the authors. Xie took the lead in data collection, along with Agiro, and data interpretation was performed by all the authors. The manuscript was written by Xie and Agiro, along with DeVries, and revised by Xie, Agiro, and Devries, along with Bowman.

  16. Evaluation of rumble strips.

    DOT National Transportation Integrated Search

    1974-01-01

    Rumble strips have been used for a number of years at locations where a physical stimulus was needed to alert a motorist to some hazard. However, little study has been done to determine the optimum spacings for the strips. Through testing existing Vi...

  17. Development of solid - based paper strips for rapid diagnosis of Pseudorabies infection.

    PubMed

    Joon Tam, Yew; Mohd Lila, Mohd Azmi; Bahaman, Abdul Rani

    2004-12-01

    Pseudorabies (Aujeszky's disease) is an economically significant disease of swine known to cause central nervous disorders, respiratory disease, reproductive failure and mortality in infected pigs. In attempts to eradicate the disease from becoming endemic, early detection is important to prevent further economic losses and to allow for detection and removal of infected pigs in domestic herds. Thus, a rapid and sensitive technique is necessary for the detection of the virus. For rapid and simple examination, an immuno - chromatographic lateral - flow assay system based on immunologic recognition of specific pseudorabies virus antigen was developed by utilising, as signal generator, colloidal gold conjugated to secondary antibody to detect primary or sample antibody in the sera of pseudorabies infected animals. The pseudorabies virus used as a capture antigen in the test strip was first cultivated in VERO cell culture and then purified by sucrose gradient separation to produce the viral protein concentration of 3.8 mg/ml. The standard pseudorabies antigens reacted well with the hyperimmune serum (HIS). The antibody detection system is basically composed of colloidal gold - labelled antibodies fixed on a conjugate pad, and the complementary pseudorabies antigen immobilised onto a nitrocellulose membrane forming capture zone. If the target antibody is present in a specimen, the colloidal gold-labelled antibody will form a complex with the antibody sample. Subsequently, the formed complex will migrate to the capture zone and is then bound to the solid phase via antigen - antibody interaction. As a result, a signal marker is generated by the accumulation of colloidal gold for detection confirmation. The results obtained demonstrated that the optimum combination of pseudorabies antigen needed as the capture reagent and gold conjugate as secondary antibody recognition marker was at a concentration of 0.38mg/ml and at 1:10 dilution factor respectively. The sensitivity of the solid - based test strip towards pseudorabies antibodies was high with a detection limit of 1 to 10,000 - dilution factor. The specificity of the assay was 100% with no cross - reaction being observed with other sera or antibodies. Accurate reading time needed for confirmation of the assay can be completed in 5 min with a whole blood sample of 25 microl. The colloidal gold - labelled antibody is stable at room temperature for 6 months or more (data not shown). Findings from this study indicated that the solid - based test strip assay system provided high sensitivity and specificity for the detection of pseudorabies at low levels of antibody concentration. The assay was rapid, simple, cheap, and does not require any sophisticated equipment. Thus, the solid based test strip will be a useful serological screening technique or for rapid diagnosis of an infectious disease in target populations of animals characterised by heterogeneous antibody responses.

  18. FIBER AND INTEGRATED OPTICS: Matching of fiber and strip optical waveguides by graded-index optical matching components

    NASA Astrophysics Data System (ADS)

    Shmal'ko, A. V.; Gordova, M. R.; Lamekin, V. F.; Nikolaev, I. V.; Sakharov, V. V.; Smirnov, V. L.; Polyantsev, A. S.

    1990-01-01

    A method for selection and calculation of the parameters of axisymmetric and anamorphic graded-index lenses for optical matching devices is developed and tested. These devices are intended for detachable connectors joining single-mode fibers to strip optical waveguides and are characterized by a greater tolerance to a mismatch between these waveguides. An experimental study is reported of a prototype of an optical matching device based on graded-index lenses characterized by insertion losses from 1-3 dB.

  19. Solderability test system

    DOEpatents

    Yost, Fred; Hosking, Floyd M.; Jellison, James L.; Short, Bruce; Giversen, Terri; Reed, Jimmy R.

    1998-01-01

    A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time.

  20. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    PubMed

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  1. Universal control and measuring system for modern classic and amorphous magnetic materials single/on-line strip testers

    NASA Astrophysics Data System (ADS)

    Zemánek, Ivan; Havlíček, Václav

    2006-09-01

    A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.

  2. Fentanyl self-testing outside supervised injection settings to prevent opioid overdose: Do we know enough to promote it?

    PubMed

    McGowan, Catherine R; Harris, Magdalena; Platt, Lucy; Hope, Vivian; Rhodes, Tim

    2018-05-11

    Since 2013, North America has experienced a sharp increase in unintentional fatal overdoses: fentanyl, and its analogues, are believed to be primarily responsible. Currently, the most practical means for people who use drugs (PWUD) to avoid or mitigate risk of fentanyl-related overdose is to use drugs in the presence of someone who is in possession of, and experienced using, naloxone. Self-test strips which detect fentanyl, and some of its analogues, have been developed for off-label use allowing PWUD to test their drugs prior to consumption. We review the evidence on the off-label sensitivity and specificity of fentanyl test strips, and query whether the accuracy of fentanyl test strips might be mediated according to situated practices of use. We draw attention to the weak research evidence informing the use of fentanyl self-testing strips. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Screening of (-SEA) α-thalassaemia using an immunochromatographic strip assay for the ζ-globin chain in a population with a high prevalence and heterogeneity of haemoglobinopathies.

    PubMed

    Jomoui, Wittaya; Fucharoen, Goonnapa; Sanchaisuriya, Kanokwan; Fucharoen, Supan

    2017-01-01

    The presence of the ζ-globin chain is a good marker of (-- SEA ) α 0 -thalassaemia. We evaluated an immunochromatographic (IC) strip assay for ζ-globin in screening for (-- SEA ) α 0 -thalassaemia in a population with a high prevalence and heterogeneity of haemoglobinopathies. The study was carried out on 300 screen positive blood samples of Thai individuals. The IC strip assay for the ζ-globin chain was performed on all samples. The results were interpreted with thalassaemia genotyping using standard haemoglobin and DNA analyses. Several thalassaemia genotypes were noted. Among the 300 subjects investigated, 79 had a positive IC strip assay for ζ-globin and (-- SEA ) α 0 -thalassaemia was identified in 40 of them. No (-- SEA ) α 0 -thalassaemia was detected in the remaining 39 samples with a positive IC strip test result or in the 221 samples with a negative IC strip test result. Further DNA analysis identified α + -thalassaemia in 25 of the 39 (-- SEA ) α 0 -thalassaemia negative samples. Using this IC strip assay in combination with a conventional screening protocol for (-- SEA ) α 0 -thalassaemia could provide sensitivity and specificity of 100% and 90.4%, respectively. IC strip assay for ζ-globin is simple, rapid and does not require sophisticated equipment. Use of this test in addition to the existing screening protocol could detect potential (-- SEA ) α 0 -thalassaemia leading to a significant reduction in the workload of DNA analysis. This could be used in areas where haemoglobinopathies are prevalent and heterogeneous but molecular testing is not available. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid.

    PubMed

    Warrener, Lenesha; Slibinskas, Rimantas; Chua, Kaw Bing; Nigatu, Wondatir; Brown, Kevin E; Sasnauskas, Kestutis; Samuel, Dhanraj; Brown, David

    2011-09-01

    To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips. The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips. With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C. The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

  5. A structural review of foliar glands in Passiflora L. (Passifloraceae)

    PubMed Central

    da Costa Silva, Delmira; Flavia de Albuquerque Melo-de-Pinna, Gladys

    2017-01-01

    Extrafloral glands in Passifloraceae species have aroused the interest of many researchers because of their wide morphological diversity. The present work analyzed the foliar glands on 34 species of Passiflora from samples containing glands in the petiole and foliar blade fixed in 50% solution of formaldehyde-ethanol-acetic acid and stored in a 70% ethanol solution. For anatomical analyses, part of the material was embedded in Paraplast, longitudinally sectioned and double stained with safranin and astra blue. Scanning electron microscopy analysis was also carried out. To analyze the presence of sugars in the secretion of foliar glands, a glucose strip test was used. Based on the results of morphological, anatomical and glucose strip tests, the foliar secretory glands in Passiflora can be grouped into two categories: Type I glands, defined as nectaries, can be elevated or flattened, and can have a sugar content high enough to be detected by the glucose strip test analysis. Type II glands are elevated and did not show a positive reaction to the glucose strip test. From an anatomical viewpoint, glands characterized as extrafloral nectaries show a multistratified secretory epidermis, typically followed by two flat layers of nectariferous parenchyma with dense content. Internal to these layers, vascular bundles are immersed in the subsecretory parenchyma and terminate in phloem cells. On the other hand, type II glands show a single layer of elongated secretory epidermal cells. Internal to this single layer, parenchyma and vascular tissue with both phloem and xylem elements can be observed. The analyzed species show a wide diversity of gland shape and distribution, and the combined analysis of morphology, anatomy and preliminary tests for the presence of glucose in the exudate in different Passiflora subgenera suggests the occurrence of two categories of glands: nectaries and resin glands. PMID:29136029

  6. Calibrating ultrasonic test equipment for checking thin metal strip stock

    NASA Technical Reports Server (NTRS)

    Peterson, R. M.

    1967-01-01

    Calibration technique detects minute laminar-type discontinuities in thin metal strip stock. Patterns of plastic tape are preselected to include minutely calculated discontinuities and the tape is applied to the strip stock to intercept the incident sonic beam.

  7. A rapid immunochromatographic test strip for detecting rabies virus antibody.

    PubMed

    Wang, Hualei; Feng, Na; Yang, Songtao; Wang, Chengyu; Wang, Tiecheng; Gao, Yuwei; Su, Jianqing; Zheng, Xuexing; Hou, Xiaoqiang; Huang, Hainan; Yang, Ruimei; Zou, Xiaohuan; Huang, Geng; Xia, Xianzhu

    2010-12-01

    An immunochromatographic test strip (ICTS) for detecting antibodies to rabies virus was developed, using colloidal gold particles labeled with rabies virus glycoprotein as the tracer. The assay was evaluated using sera from dogs immunized with various commercial rabies vaccines, or from dogs in the clinics and sera from dogs immunized with vaccines against pathogens other than rabies virus, and negative sera from a wide variety of animal sources, including dogs, mice, and cats which had never been vaccinated. The ICTS was found to be highly specific for antibodies against rabies virus, with a detection limit of 0.5IU/ml as measured by the fluorescent antibody virus neutralization (FAVN) test. Compared with the FAVN test, the specificity and sensitivity of ICTS were 98.2% and 90.4%, respectively. There was an excellent agreement between results obtained by the ICTS and FAVN tests (kappa=0.888). Strips stored at 4°C in a plastic bag with a desiccant retained their specificity and sensitivity for at least 15 months, and strips stored at ambient temperature remained stable for 12 months. The immunochromatographic test strip may therefore be useful for clinical laboratories lacking specialized equipment and for diagnosis in the field for rapid detection of rabies virus-specific antibodies. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. A SIMPLE ASSAY FOR 2,4-DICHLOROPHENOXYACETIC ACID USING COATED TEST-STRIPS

    EPA Science Inventory

    Immunoassay test strips utilizing ascending chromatography has been devised for the detection of 2.4-dichlorophenoxyacetic acid (2,4-D). This test requires no instrumentation, inexpensive reagents and relies on the application of antibodies to 2,4-D adsorbed onto colloidal gol...

  9. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    PubMed

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  10. A highly selective colorimetric and ratiometric fluorescent probe for instantaneous sensing of Hg2+ in water, soil and seafood and its application on test strips.

    PubMed

    Lan, Linxin; Niu, Qingfen; Li, Tianduo

    2018-09-06

    A new simple and efficient oligothiophene-based colorimetric and ratiometric fluorescent probe has been developed for highly sensitive and fast detection of Hg 2+ in water, soil and seafood. The probe 5-(1,3-dithiolan-2-yl)-2,2':5',2″-terthiophene 3 TS can selectively detect Hg 2+ via the Hg 2+ -promoted deprotection reaction of thioacetals, which caused a remarkable color change from colorless to yellow and a strong fluorescence enhancement with emission color varying from blue to yellow, enabling naked-eye detection of Hg 2+ . The probe shows high sensitivity with the detection limit down to 1.03 × 10 -8  M. Visual color changes of 3 TS were observed on filter paper and TLC testing strips when they were impregnated on testing strips and immersed in Hg 2+ solution. Moreover, the probe 3 TS has been successfully used to rapidly detect trace amounts of hazardous Hg 2+ ions in tap, distilled, river and lake water, cropland soil, fish, shrimp and kelp samples with acceptable results and good recoveries. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Strip clearcutting to regenerate northern hardwoods.

    Treesearch

    Frederick T. Metzger

    1980-01-01

    Describes results of strip clearcutting trials in mature northern hardwood and hemlock-hardwood stands in the Lake States. Two strip width and orientations were tested, with and without herbicide treatment of the advance regeneration. Establishment, growth, and species composition of the regeneration were assessed.

  12. Effect of moisture on typical Virginia surface treatment materials.

    DOT National Transportation Integrated Search

    1970-01-01

    Several aspects of the stripping and whip off characteristics of typical Virginia surface treatment materials were investigated. Sixty different binder-aggregate combinations were tested with the AASHO Designation T182-57 stripping test, a plate imme...

  13. The variability of the indirect tensile stripping test.

    DOT National Transportation Integrated Search

    1990-01-01

    The purpose of this investigation was to determine the variability of the Virginia Department of Transportation's (VDOT) indirect tensile stripping test. Five contractor labs and eight VDOT labs participated in the study. Each lab performed three rep...

  14. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas

    PubMed Central

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg

    2015-01-01

    Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180

  15. Construction and response of a highly granular scintillator-based electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Repond, J.; Xia, L.; Eigen, G.; Price, T.; Watson, N. K.; Winter, A.; Thomson, M. A.; Cârloganu, C.; Blazey, G. C.; Dyshkant, A.; Francis, K.; Zutshi, V.; Gadow, K.; Göttlicher, P.; Hartbrich, O.; Kotera, K.; Krivan, F.; Krüger, K.; Lu, S.; Lutz, B.; Reinecke, M.; Sefkow, F.; Sudo, Y.; Tran, H. L.; Kaplan, A.; Schultz-Coulon, H.-Ch.; Bilki, B.; Northacker, D.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Sekiya, I.; Suehara, T.; Yamashiro, H.; Yoshioka, T.; Alamillo, E. Calvo; Fouz, M. C.; Marin, J.; Navarrete, J.; Pelayo, J. Puerta; Verdugo, A.; Chadeeva, M.; Danilov, M.; Gabriel, M.; Goecke, P.; Graf, C.; Israeli, Y.; Kolk, N. Van Der; Simon, F.; Szalay, M.; Windel, H.; Bilokin, S.; Bonis, J.; Pöschl, R.; Thiebault, A.; Richard, F.; Zerwas, D.; Balagura, V.; Boudry, V.; Brient, J.-C.; Cornat, R.; Cvach, J.; Janata, M.; Kovalcuk, M.; Kvasnicka, J.; Polak, I.; Smolik, J.; Vrba, V.; Zalesak, J.; Zuklin, J.; Choi, W.; Kotera, K.; Nishiyama, M.; Sakuma, T.; Takeshita, T.; Tozuka, S.; Tsubokawa, T.; Uozumi, S.; Jeans, D.; Ootani, W.; Liu, L.; Chang, S.; Khan, A.; Kim, D. H.; Kong, D. J.; Oh, Y. D.; Ikuno, T.; Sudo, Y.; Takahashi, Y.; Götze, M.; Calice Collaboration

    2018-04-01

    A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X0 depth and 180 × 180mm2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3mm3 scintillator strips. This prototype was tested using electrons of 2-32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12 . 5 ± 0 . 1(stat.) ± 0 . 4(syst.)) % /√{ E [ GeV ] } ⊕(1.2 ± 0.1 (stat.)-0.7+0.6 (syst.)) %, where the uncertainties correspond to statistical and systematic sources, respectively.

  16. Frequency of self-monitoring blood glucose and attainment of HbA1c target values.

    PubMed

    Elgart, Jorge F; González, Lorena; Prestes, Mariana; Rucci, Enzo; Gagliardino, Juan J

    2016-02-01

    Test strips for self-monitoring of blood glucose (SMBG) represent in Argentina, around 50 % of diabetes treatment cost; the frequency of their use is closely associated with hyperglycemia treatment. However, the favorable impact of SMBG on attainment of HbA1c goal in different treatment conditions remains controversial. We therefore attempted to estimate the relationship between use of SMBG test strips and degree of attainment of metabolic control in an institution of our social security subsector (SSS) in which provision is fully covered and submitted to a regular audit system. Observational retrospective study using information of 657 patients with T2DM (period 2009-2010) from the database of the Diabetes and Other Cardiovascular Risk Factors Program (DICARO) of one institution of our SSS. DICARO provides-with an audit system-100 % coverage for all drugs and keeps records of clinical, metabolic and treatment data from every patient. The average monthly test strips/patient used for SMBG increased as a function of treatment intensification: Monotherapy with oral antidiabetic drugs (OAD) < combined OAD therapy < insulin treatment. In every condition, the number was larger in people with target HbA1c levels. Test strips represented the larger percentage of total prescription cost. In our population, the type of hyperglycemia treatment was the main driver of test strip use for SMBG; in every condition tested, targeted HbA1c values were associated with greater strip use. Patient education and prescription audit may optimize its use and treatment outcomes.

  17. Solderability test system

    DOEpatents

    Yost, F.; Hosking, F.M.; Jellison, J.L.; Short, B.; Giversen, T.; Reed, J.R.

    1998-10-27

    A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time. 11 figs.

  18. In-depth survey report: Assisting furniture strippers in reducing the risk from methylene chloride stripping formulations at Los Angeles Stripping and Refinishing Center, Los Angeles, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estill, C.F.; Kovein, R.J.; Jones, J.H.

    1999-03-26

    The National Institute for Occupational Safety and Health (NIOSH) is currently conducting research on ventilation controls to reduce furniture stripping exposures to methylene chloride to the OSHA PEL of 25 ppm. Low cost ventilation systems were designed by NIOSH researchers along with Benny Bixenman of Benco Sales, Inc. (Forney, TX). The controls were constructed and installed by Benco Sales. This report compares the methylene chloride levels of one worker stripping furniture using the recently installed ventilation controls and using the existing controls. During the survey, two different chemical stripping solutions (a standard formulation and a low methylene chloride content formulation)more » were used and compared. This survey tested three control combinations: (1) new ventilation, low methylene chloride stripper, (2) new ventilation, standard stripping solution, and (3) old ventilation, standard stripping solution. During each test, sorbent tube sampling and real-time sampling were employed. Sorbent tube, data collected in the worker's breathing zone, ranged from 300 to 387 ppm. Real-time data showed breathing zone exposures to range from 211 to 383 ppm while stripping and 164 to 230 ppm while rinsing. Data were inconclusive to determine which ventilation system or stripping solution produced the lowest exposures. Recommendations are made in the report to improve the newly installed ventilation controls.« less

  19. Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting.

    PubMed

    Claerhout, Helena; De Prins, Martine; Mesotten, Dieter; Van den Berghe, Greet; Mathieu, Chantal; Van Eldere, Johan; Vanstapel, Florent

    2016-01-01

    We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs. the comparator hexokinase glucose-6-phosphate-dehydrogenase (HK/G6PDH) assay on a Cobas c702 analyzer (Roche). Recovery of spiked glucose was linear up to 19.3 mmol/L (347 mg/dL) with a slope of 0.91-0.94 for all GMs. Repeatability estimated by pooling duplicate measurements on samples below (n=9), in (n=51) or above (n=80) the 4.2-5.9 mM (74-106 mg/dL) range were for Freestyle Precision Pro: 4.2%, 4.0%, 3.6%; StatStrip Connectivity Meter: 4.0%, 4.3%, 4.5%; and ACCU-CHEK Inform II: 1.4%, 2.5%, 3.5%. GMs were in agreement with the comparator method. The BGA outperformed the GMs, with a MARD of 3.9% compared to 6.5%, 5.8% and 4.4% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. Zero % of the BGA results deviated more than the FDA 10% criterion as compared to 9.4%, 3.7% and 2.2% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. For all GMs, icodextrin did not interfere. Variation in the putative influence factors hematocrit and O2 tension could not explain observed differences with the comparator method. GMs quantified blood glucose in whole blood at about the 10% total error criterion, proposed by the FDA for prescription use.

  20. A fluorescent immunochromatographic strip test using a quantum dot-antibody probe for rapid and quantitative detection of 1-aminohydantoin in edible animal tissues.

    PubMed

    Le, Tao; Zhang, Zhihao; Wu, Juan; Shi, Haixing; Cao, Xudong

    2018-01-01

    A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correlation coefficient of 0.9656 and a 50% inhibitory concentration of 4.51 ng/mL. The limit of detection was 0.14 ng/g, which was below the minimum required performance limit of 1 μg/kg for AHD established by the European Commission. The recoveries for AHD ranged from 81.5% to 108.2%, with coefficients of variation below 13%, based on intraday and interday analysis. Furthermore, for AHD in real samples, the ICST showed high reliability and high correlation with liquid chromatography-tandem mass spectrometry (correlation coefficient of 0.9916). To the best of our knowledge, this is the first report of a novel and sensitive method based on a fluorescent ICST to detect AHD below the minimum required performance limit. The ICST demonstrated high reliability, and could be ideally suited for rapid, simple, and on-site screening of AHD contamination in animal tissues. Graphical abstract A rapid, simple, and sensitive fluorescent immunochromatographic strip test that is based on quantum dots was developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. 2-NBA 2-nitrobenzaldehyde, NP nitrophenyl.

  1. Distributed pressure sensors for a urethral catheter.

    PubMed

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S

    2015-01-01

    A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi.

  2. Effect of tooth whitening strips on fatigue resistance and flexural strength of bovine dentin in vitro

    PubMed Central

    Kim, Namhee; De Souza, Grace M.

    2017-01-01

    Objective To determine the effects of whitening strips on bovine dentin fatigue resistance and flexural strength in vitro. Materials and methods A total of eighty bovine dentin specimens (2x2x17mm) were treated with either: control glycerine gel on plastic film wrap or whitening strips containing 9.5% hydrogen peroxide. Treatment was applied for 30 minutes, twice a day, for 1- or 4-weeks. After the last treatment, ten specimens per group were randomly selected to undergo fatigue testing (106 cycles, 3Hz, 20N) while the other ten were subjected to flexural strength testing after ten days of storage in artificial saliva. Kaplan-Meier method with a log rank test, Wilcoxon test and Cox regression were used to assess fatigue test results (p<0.05). One-way ANOVA and Tukey’s tests were used to compare the flexural strength results (p<0.05). Results There were significant differences in survival during the fatigue test among the groups (p<0.001). Treatment (control or bleach) was a significant factor for specimen survival (p<0.001, Exp(B) = 33.45). There were significant differences in mean flexural strength (p<0.001). No significant difference was found between “1-wk control” and “4-wk control”. The mean flexural strength and fatigue resistance of the “4-wk bleach” were significantly lower than all the other groups. Conclusions The use of whitening strips reduced the fatigue resistance and flexural strength of bovine dentin in vitro. Until the effect of whitening strips on mechanical properties of human dentin is fully elucidated, it remains prudent to advise patients to avoid excessive direct use of whitening strips on dentin. PMID:28278191

  3. Online aptitude automatic surface quality inspection system for hot rolled strips steel

    NASA Astrophysics Data System (ADS)

    Lin, Jin; Xie, Zhi-jiang; Wang, Xue; Sun, Nan-Nan

    2005-12-01

    Defects on the surface of hot rolled steel strips are main factors to evaluate quality of steel strips, an improved image recognition algorithm are used to extract the feature of Defects on the surface of steel strips. Base on the Machine vision and Artificial Neural Networks, establish a defect recognition method to select defect on the surface of steel strips. Base on these research. A surface inspection system and advanced algorithms for image processing to hot rolled strips is developed. Preparing two different fashion to lighting, adopting line blast vidicon of CCD on the surface steel strips on-line. Opening up capacity-diagnose-system with level the surface of steel strips on line, toward the above and undersurface of steel strips with ferric oxide, injure, stamp etc of defects on the surface to analyze and estimate. Miscarriage of justice and alternate of justice rate not preponderate over 5%.Geting hold of applications on some big enterprises of steel at home. Experiment proved that this measure is feasible and effective.

  4. Assessment of practicality of remote sensing techniques for a study of the effects of strip mining in Alabama

    NASA Technical Reports Server (NTRS)

    Hughes, T. H.; Dillion, A. C., III; White, J. R., Jr.; Drummond, S. E., Jr.; Hooks, W. G.

    1975-01-01

    Because of the volume of coal produced by strip mining, the proximity of mining operations, and the diversity of mining methods (e.g. contour stripping, area stripping, multiple seam stripping, and augering, as well as underground mining), the Warrior Coal Basin seemed best suited for initial studies on the physical impact of strip mining in Alabama. Two test sites, (Cordova and Searles) representative of the various strip mining techniques and environmental problems, were chosen for intensive studies of the correlation between remote sensing and ground truth data. Efforts were eventually concentrated in the Searles Area, since it is more accessible and offers a better opportunity for study of erosional and depositional processes than the Cordova Area.

  5. Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    NASA Astrophysics Data System (ADS)

    Mikestikova, M.; Allport, P. P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Kuczewski, P.; Lynn, D.; Hommels, L. B. A.; Ullan, M.; Bloch, I.; Gregor, I. M.; Tackmann, K.; Hauser, M.; Jakobs, K.; Kuehn, S.; Mahboubi, K.; Mori, R.; Parzefall, U.; Clark, A.; Ferrere, D.; Sevilla, S. Gonzalez; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; McMullen, T.; McEwan, F.; O'Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Stastny, J.; Bevan, A.; Beck, G.; Milke, C.; Domingo, M.; Fadeyev, V.; Galloway, Z.; Hibbard-Lubow, D.; Liang, Z.; Sadrozinski, H. F.-W.; Seiden, A.; To, K.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Jinnouchi, O.; Hara, K.; Sato, K.; Hagihara, M.; Iwabuchi, S.; Bernabeu, J.; Civera, J. V.; Garcia, C.; Lacasta, C.; Marti i Garcia, S.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.

    2016-09-01

    A radiation hard n+-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the "ATLAS ITk Strip Sensor collaboration" and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in "punch-through protection" (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1×1016 neq/cm2, by reactor neutron fluence of 1×1015 neq/cm2 and by gamma rays from 60Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for micro-discharge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07.

  6. Development and test of flexible film coupon strips for use as a sampling technique

    NASA Technical Reports Server (NTRS)

    Aldridge, C.

    1969-01-01

    Film consisting of a gelatin base serves as a flexible, water soluble microbiological assay coupon for clean room use. It is nontoxic to microorganisms and capable of remaining unchanged during periods of storage.

  7. Preparation and Testing of Plant Seed Meal-based Wood Adhesives

    PubMed Central

    He, Zhongqi; Chapital, Dorselyn C.

    2015-01-01

    Recently, the interest in plant seed meal-based products as wood adhesives has steadily increased, as these plant raw materials are considered renewable and environment-friendly. These natural products may serve as alternatives to petroleum-based adhesives to ease environmental and sustainability concerns. This work demonstrates the preparation and testing of the plant seed-based wood adhesives using cottonseed and soy meal as raw materials. In addition to untreated meals, water washed meals and protein isolates are prepared and tested. Adhesive slurries are prepared by mixing a freeze-dried meal product with deionized water (3:25 w/w) for 2 hr. Each adhesive preparation is applied to one end of 2 wood veneer strips using a brush. The tacky adhesive coated areas of the wood veneer strips are lapped and glued by hot-pressing. Adhesive strength is reported as the shear strength of the bonded wood specimen at break. Water resistance of the adhesives is measured by the change in shear strength of the bonded wood specimens at break after water soaking. This protocol allows one to assess plant seed-based agricultural products as suitable candidates for substitution of synthetic-based wood adhesives. Adjustments to the adhesive formulation with or without additives and bonding conditions could optimize their adhesive properties for various practical applications. PMID:25867092

  8. Preparation and testing of plant seed meal-based wood adhesives.

    PubMed

    He, Zhongqi; Chapital, Dorselyn C

    2015-03-05

    Recently, the interest in plant seed meal-based products as wood adhesives has steadily increased, as these plant raw materials are considered renewable and environment-friendly. These natural products may serve as alternatives to petroleum-based adhesives to ease environmental and sustainability concerns. This work demonstrates the preparation and testing of the plant seed-based wood adhesives using cottonseed and soy meal as raw materials. In addition to untreated meals, water washed meals and protein isolates are prepared and tested. Adhesive slurries are prepared by mixing a freeze-dried meal product with deionized water (3:25 w/w) for 2 hr. Each adhesive preparation is applied to one end of 2 wood veneer strips using a brush. The tacky adhesive coated areas of the wood veneer strips are lapped and glued by hot-pressing. Adhesive strength is reported as the shear strength of the bonded wood specimen at break. Water resistance of the adhesives is measured by the change in shear strength of the bonded wood specimens at break after water soaking. This protocol allows one to assess plant seed-based agricultural products as suitable candidates for substitution of synthetic-based wood adhesives. Adjustments to the adhesive formulation with or without additives and bonding conditions could optimize their adhesive properties for various practical applications.

  9. Development of semiconductor tracking: The future linear collider case

    NASA Astrophysics Data System (ADS)

    Savoy-Navarro, Aurore

    2011-04-01

    An active R&D on silicon tracking for the linear collider, SiLC, is pursued since several years to develop the new generation of large area silicon trackers for the future linear collider(s). The R&D objectives on new sensors, new front end processing of the signal, and the related mechanical and integration challenges for building such large detectors within the proposed detector concepts are described. Synergies and differences with the LHC construction and upgrades are explained. The differences between the linear collider projects, namely the international linear collider, ILC, and the compact linear collider, CLIC, are discussed as well. Two final objectives are presented for the construction of this important sub-detector for the future linear collider experiments: a relatively short term design based on micro-strips combined or not with a gaseous central tracker and a longer term design based on an all-pixel tracker.The R&D objectives on sensors include single sided micro-strips as baseline for the shorter term with the strips from large wafers (at least 6 in), 200 μm thick, 50 μm pitch and the edgeless and alignment friendly options. This work is conducted by SiLC in collaboration with three technical research centers in Italy, Finland, and Spain and HPK. SiLC is studied as well, using advanced Si sensor technologies for higher granularity trackers especially short strips and pixels all based on 3D technology. New Deep Sub-Micron CMOS mix mode (analog and digital) FE and readout electronics are developed to fully process the detector signals currently adapted to the ILC cycle. It is a high-level processing and a fully programmable ASIC; highly fault tolerant. In its latest version, handling 128 channels will equip these next coming years larger size silicon tracking prototypes at test beams. Connection of the FEE chip on the silicon detector especially in the strip case is a major issue. Very preliminary results with inline pitch adapter based on wiring were just achieved. Bump-bonding or 3D vertical interconnect is the other SiLC R&D objective. The goal is to simplify the overall architecture and decrease the material budget of these devices. Three tracking concepts are briefly discussed, two of which are part of the ILC Letter of Intent of the ILD and SiD detector concepts. These last years, SiLC successfully performed beam tests to experience and test these R&D lines.

  10. Use of moisture induced stress testing to evaluate stripping potential of hot mix asphalt (HMA).

    DOT National Transportation Integrated Search

    2012-07-01

    Stripping of hot mix asphalt (HMA) in the field is an ongoing issue for many Departments of Transportation : (DOTs). A leading cause of stripping is hydraulic scouring. The Moisture Induced Stress Tester (MIST) is a recently : developed technology th...

  11. Comparative Study of rK39 Leishmania Antigen for Serodiagnosis of Visceral Leishmaniasis: Systematic Review with Meta-Analysis

    PubMed Central

    Maia, Zuinara; Lírio, Monique; Mistro, Sóstenes; Mendes, Carlos Maurício Cardeal; Mehta, Sanjay R.; Badaro, Roberto

    2012-01-01

    Background The rK39 recombinant protein is derived from a specific antigen produced by the Leishmania donovani complex, and has been used in the last two decades for the serodiagnosis of visceral leishmaniasis. We present here a systematic review and meta-analysis of studies evaluating serologic assays to diagnose visceral leishmaniasis to determine the accuracy of rK39 antigen in comparison to the use of other antigen preparations. Methodology/Principal Findings A systematic review with meta-analysis of the literature was performed to compare the rK39 strip-test and ELISA formats against serological tests using promastigote antigens derived from whole or soluble parasites for Direct Aglutination Test (DAT), Indirect Immunofluorescence test (IFAT) and ELISA with a promastigote antigen preparation (p-ELISA). Gold standard diagnosis was defined by the demonstration of amastigotes on hematological specimens. A database search was performed on Medline, Lilacs, Scopus, Isi Web of Science, and Cochrane Library. Quality of data was assessed using the QUADAS questionnaire. A search of the electronic databases found 352 papers of which only 14 fulfilled the selection criteria. Three evaluated the rK39 ELISA, while 13 evaluated the rK39 immunochromatographic strip test. The summarized sensitivity for the rK39-ELISA was 92% followed by IFAT 88% and p-ELISA 87%. The summarized specificity for the three diagnostic tests was 81%, 90%, and 77%. Studies comparing the rK39 strip test with DAT found a similar sensitivity of 94%, although the DAT had a slightly higher specificity. The rK39 strip test was more sensitive and specific than the IFAT and p-ELISA. We did not detect any difference in the sensitivity and specificity between strips produced by different manufacturers. Conclusions The rK39 protein used either in a strip test or in an ELISA, and the DAT are the best choices for implementation of rapid, easy and efficient test for serodiagnosis of VL. PMID:22303488

  12. Comparative study of rK39 Leishmania antigen for serodiagnosis of visceral leishmaniasis: systematic review with meta-analysis.

    PubMed

    Maia, Zuinara; Lírio, Monique; Mistro, Sóstenes; Mendes, Carlos Maurício Cardeal; Mehta, Sanjay R; Badaro, Roberto

    2012-01-01

    The rK39 recombinant protein is derived from a specific antigen produced by the Leishmania donovani complex, and has been used in the last two decades for the serodiagnosis of visceral leishmaniasis. We present here a systematic review and meta-analysis of studies evaluating serologic assays to diagnose visceral leishmaniasis to determine the accuracy of rK39 antigen in comparison to the use of other antigen preparations. A systematic review with meta-analysis of the literature was performed to compare the rK39 strip-test and ELISA formats against serological tests using promastigote antigens derived from whole or soluble parasites for Direct Aglutination Test (DAT), Indirect Immunofluorescence test (IFAT) and ELISA with a promastigote antigen preparation (p-ELISA). Gold standard diagnosis was defined by the demonstration of amastigotes on hematological specimens. A database search was performed on Medline, Lilacs, Scopus, Isi Web of Science, and Cochrane Library. Quality of data was assessed using the QUADAS questionnaire. A search of the electronic databases found 352 papers of which only 14 fulfilled the selection criteria. Three evaluated the rK39 ELISA, while 13 evaluated the rK39 immunochromatographic strip test. The summarized sensitivity for the rK39-ELISA was 92% followed by IFAT 88% and p-ELISA 87%. The summarized specificity for the three diagnostic tests was 81%, 90%, and 77%. Studies comparing the rK39 strip test with DAT found a similar sensitivity of 94%, although the DAT had a slightly higher specificity. The rK39 strip test was more sensitive and specific than the IFAT and p-ELISA. We did not detect any difference in the sensitivity and specificity between strips produced by different manufacturers. The rK39 protein used either in a strip test or in an ELISA, and the DAT are the best choices for implementation of rapid, easy and efficient test for serodiagnosis of VL.

  13. Model-based tomographic reconstruction

    DOEpatents

    Chambers, David H; Lehman, Sean K; Goodman, Dennis M

    2012-06-26

    A model-based approach to estimating wall positions for a building is developed and tested using simulated data. It borrows two techniques from geophysical inversion problems, layer stripping and stacking, and combines them with a model-based estimation algorithm that minimizes the mean-square error between the predicted signal and the data. The technique is designed to process multiple looks from an ultra wideband radar array. The processed signal is time-gated and each section processed to detect the presence of a wall and estimate its position, thickness, and material parameters. The floor plan of a building is determined by moving the array around the outside of the building. In this paper we describe how the stacking and layer stripping algorithms are combined and show the results from a simple numerical example of three parallel walls.

  14. Beam test of CSES silicon strip detector module

    NASA Astrophysics Data System (ADS)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  15. Metabolic markers and microecological characteristics of tongue coating in patients with chronic gastritis

    PubMed Central

    2013-01-01

    Background In Traditional Chinese Medicine (TCM), tongue diagnosis has been an important diagnostic method for the last 3000 years. Tongue diagnosis is a non-invasive, simple and valuable diagnostic tool. TCM treats the tongue coating on a very sensitive scale that reflects physiological and pathological changes in the organs, especially the spleen and stomach. Tongue coating can diagnose disease severity and determine the TCM syndrome (“Zheng” in Chinese). The biological bases of different tongue coating appearances are still poorly understood and lack systematic investigation at the molecular level. Methods Tongue coating samples were collected from 70 chronic gastritis patients and 20 normal controls. 16S rRNA denatured gradient gel electrophoresis (16S rRNA–DGGE) and liquid chromatography and mass spectrometry (LC–MS) were designed to profile tongue coatings. The statistical techniques used were principal component analysis and partial least squares–discriminate analysis. Results Ten potential metabolites or markers were found in chronic gastritis patients, including UDP-D-galactose, 3-ketolactose, and vitamin D2, based on LC–MS. Eight significantly different strips were observed in samples from chronic gastritis patients based on 16S rRNA–DGGE. Two strips, Strips 8 and 10, were selected for gene sequencing. Strip 10 sequencing showed a 100% similarity to Rothia mucilaginosa. Strip 8 sequencing showed a 96.2% similarity to Moraxella catarrhalis. Conclusions Changes in glucose metabolism could possibly form the basis of tongue coating conformation in chronic gastritis patients. The study revealed important connections between metabolic components, microecological components and tongue coating in chronic gastritis patients. Compared with other diagnostic regimens, such as blood tests or tissue biopsies, tongue coating is more amenable to, and more convenient for, both patients and doctors. PMID:24041039

  16. FIBER AND INTEGRATED OPTICS: Waveguide characteristics of real optical strip waveguides

    NASA Astrophysics Data System (ADS)

    Shmal'ko, A. V.; Frolov, V. V.

    1990-01-01

    A study is reported of the influence of the parameters of real thin-film optical strip waveguides on their waveguide characteristics (propagation constants, localization of the mode field, etc.) allowing for the presence of transition layers in a transverse cross section of the base planar waveguide, for the real geometry of this section (which is nearly trapezoidal), and for the thickness of the guiding strip. Analytic expressions are obtained for the optical confinement coefficient and the effective mode format of a weakly guiding symmetric strip waveguide. It is shown that the coefficient representing the fundamental E11x(y) mode is practically independent of the relative thickness t /h (h is the thickness of the base planar waveguide) of the guiding strip provided t /h>=0.5. The corrections to the normalized effective refractive indices of the base planar and strip waveguides are found in order to allow for the real geometry and for the refractive index profile in the strip waveguide.

  17. Residual strength assessment of low velocity impact damage of graphite-epoxy laminates

    NASA Technical Reports Server (NTRS)

    Lal, K. M.

    1983-01-01

    This report contains the study of Low Velocity Transverse Impact Damage of graphite-epoxy T300/5208 composite laminates. The specimen, 100 mm diameter clamped plates, were impact damaged by a cantilever-type instrumented 1-inch diameter steel ball. Study was limited to impact velocity 6 m/sec. Rectangular strips, 50 mm x 125 mm, were cut from the impact-damage specimens so that the impact damage zone was in the center of the strips. These strips were tested in tension to obtain their residual strength. An energy dissipation model was developed to predict the residual strength from fracture mechanics concepts. Net energy absorbed I(a) was evaluated from coefficient of restitution concepts based on shear dominated theory of fiber-reinforced materials, with the modification that during loading and unloading the shear deformation are respectively elastic-plastic and elastic. Delamination energy I(d) was predicted by assuming that the stiffness of the laminate dropped due to debonding. Fiber-breakage energy, assumed to be equal to the difference of I(a) and I(d), was used to determine the residual strength. Predictions were compared with test results.

  18. Interference studies with two hospital-grade and two home-grade glucose meters.

    PubMed

    Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry

    2009-10-01

    Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was <5% except for the FreeStyle (up to 7.6%). Between-day precision was <6% for all glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was less affected in comparison with the glucose oxidase-based photometric method (LifeScan SureStep Flexx).

  19. View from second level looking down on embedded weld strips ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View from second level looking down on embedded weld strips and plugged, threaded anchors in the foundation slab. These were put in place to assist in adapting to future configurations of the test stand. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL

  20. Damage tolerance of woven graphite-epoxy buffer strip panels

    NASA Technical Reports Server (NTRS)

    Kennedy, John M.

    1990-01-01

    Graphite-epoxy panels with S glass buffer strips were tested in tension and shear to measure their residual strengths with crack-like damage. The buffer strips were regularly spaced narrow strips of continuous S glass. Panels were made with a uniweave graphite cloth where the S glass buffer material was woven directly into the cloth. Panels were made with different width and thickness buffer strips. The panels were loaded to failure while remote strain, strain at the end of the slit, and crack opening displacement were monitoring. The notched region and nearby buffer strips were radiographed periodically to reveal crack growth and damage. Except for panels with short slits, the buffer strips arrested the propagating crack. The strength (or failing strain) of the panels was significantly higher than the strength of all-graphite panels with the same length slit. Panels with wide, thick buffer strips were stronger than panels with thin, narrow buffer strips. A shear-lag model predicted the failing strength of tension panels with wide buffer strips accurately, but over-estimated the strength of the shear panels and the tension panels with narrow buffer strips.

  1. Evaluating the Whitening and Microstructural Effects of a Novel Whitening Strip on Porcelain and Composite Dental Materials

    PubMed Central

    Takesh, Thair; Sargsyan, Anik; Lee, Matthew; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra

    2017-01-01

    Aims The aim of this project was to evaluate the effects of 2 different whitening strips on color, microstructure and roughness of tea stained porcelain and composite surfaces. Methods 54 porcelain and 72 composite chips served as samples for timed application of over-the-counter (OTC) test or control dental whitening strips. Chips were divided randomly into three groups of 18 porcelain and 24 composite chips each. Of these groups, 1 porcelain and 1 composite set served as controls. The remaining 2 groups were randomized to treatment with either Oral Essentials® Whitening Strips or Crest® 3D White Whitestrips™. Sample surface structure was examined by light microscopy, profilometry and Scanning Electron Microscopy (SEM). Additionally, a reflectance spectrophotometer was used to assess color changes in the porcelain and composite samples over 24 hours of whitening. Data points were analyzed at each time point using ANOVA. Results In the light microscopy and SEM images, no discrete physical defects were observed in any of the samples at any time points. However, high-resolution SEM images showed an appearance of increased surface roughness in all composite samples. Using profilometry, significantly increased post-whitening roughness was documented in the composite samples exposed to the control bleaching strips. Composite samples underwent a significant and equivalent shift in color following exposure to Crest® 3D White Whitestrips™ and Oral Essentials® Whitening Strips. Conclusions A novel commercial tooth whitening strip demonstrated a comparable beaching effect to a widely used OTC whitening strip. Neither whitening strip caused physical defects in the sample surfaces. However, the control strip caused roughening of the composite samples whereas the test strip did not. PMID:29226023

  2. Specimen Design for Sustained Load Testing of Parallel-Laid Glass Fibre Reinforced Plastics.

    DTIC Science & Technology

    prepared by molding on a sheet of woven glass fabric and stripping this off just before bonding, to leave a roughened surface. The test specimens are 1/2 inch wide strips cut from the laminates. (Author, modified-PL)

  3. Tests for Plastic Fines in Aggregates Related to Stripping in Asphalt Paving Mixtures

    DOT National Transportation Integrated Search

    1988-03-01

    This study was undertaken for determining the best aggregate test method that indicates the presence of detrimental plastic fines in the fine aggregate, which may induce stripping in hot mix asphalt (HMA) mixtures. Ten fine aggregates representing a ...

  4. Capillary-driven surface-enhanced Raman scattering (SERS)-based microfluidic chip for abrin detection

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Deng, Min; Ga, Shan; Chen, Shouhui; Kang, Lin; Wang, Junhong; Xin, Wenwen; Zhang, Tao; You, Zherong; An, Yuan; Wang, Jinglin; Cui, Daxiang

    2014-03-01

    Herein, we firstly demonstrate the design and the proof-of-concept use of a capillary-driven surface-enhanced Raman scattering (SERS)-based microfluidic chip for abrin detection. The micropillar array substrate was etched and coated with a gold film by microelectromechanical systems (MEMS) process to integrate into a lateral flow test strip. The detection of abrin solutions of various concentrations was performed by the as-prepared microfluidic chip. It was shown that the correlation between the abrin concentration and SERS signal was found to be linear within the range of 0.1 ng/mL to 1 μg/mL with a limit of detection of 0.1 ng/mL. Our microfluidic chip design enhanced the operability of SERS-based immunodiagnostic techniques, significantly reducing the complication and cost of preparation as compared to previous SERS-based works. Meanwhile, this design proved the superiority to conventional lateral flow test strips in respect of both sensitivity and quantitation and showed great potential in the diagnosis and treatment for abrin poisoning as well as on-site screening of abrin-spiked materials.

  5. Sterilization of reusable implant components: a pilot study.

    PubMed

    Cain, J R; Mitchell, D L; Gillespie, J C

    2000-12-01

    The placement and restoration of dental implants require the use of numerous reusable instruments and components. The adequate sterilization of reusable instruments and components is essential to prevent cross contamination between patients. Sterilization usually is accomplished with single-use sterilization envelopes. A reusable sterilization vehicle would reduce costs as well as the waste generated in patient care. This study was designed to determine the efficacy of a 10-cc Pyrex test tube as a sterilization vehicle for reusable dental implant instruments and components. In this study, a reusable dental implant component was placed in a Pyrex test tube, along with a biologic test strip. A control biologic test strip was kept for each test tube. The test tube was closed with a cotton roll folded in half and placed in the opening. Twenty test tubes were prepared. five sets of 4 test tubes were placed in an autoclave in different locations with varying orientations. The autoclave completed a standard sterilization cycle. The biological monitoring service indicated that the biologic test strips in 100% of the test tubes were sterile, whereas the control strips were 100% nonsterile. A Pyrex test tube sealed with a cotton roll can serve as a sterilization vehicle for reusable dental implant instruments and components.

  6. A study of electromigration behaviors of Ge2Sb2Te5 chalcogenide nano-strips subjected to pulse bias

    NASA Astrophysics Data System (ADS)

    Huang, Yin-Hsien; Hsieh, Tsung-Eong

    2017-07-01

    Electromigration (EM) behaviors of pristine Ge2Sb2Te5 (GST) and cerium-doped GST (Ce-GST) nano-strips were investigated by the mean-time-to-failure (MTTF) tests under the pulse bias at the conditions of pulse frequency (f) ranging from 1 to 25 MHz and duty cycle ranging from 50% to 80%. Analytical results indicated that, at f greater than 10 MHz, the EM failure of GST nano-strips in pulse bias environment could be depicted by the ‘average current model’. With the aid of Black’s theory, the activation energies (E a) of EM process under pulse bias were found to be 0.63 and 0.56 eV for GST and Ce-GST nano-strips, respectively. The E a values were comparatively smaller than those observed in direct-current MTTF test of GST thin-film samples, implying the enhancement of surface diffusion and skin effect in GST nano-strips. The morphology and composition analyses indicated that the electrostatic and the electron-wind forces might simultaneously involve in the mass transport in GST nano-strips under the test conditions of this study. The composition analysis also revealed that doping could not effectively alleviate the element segregation in GST subjected to electrical bias.

  7. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis

    PubMed Central

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation. PMID:29084241

  8. Microstructure, Tensile and Fatigue Properties of Al-5 wt.%Mg Alloy Manufactured by Twin Roll Strip Casting

    NASA Astrophysics Data System (ADS)

    Heo, Joon-Young; Baek, Min-Seok; Euh, Kwang-Jun; Lee, Kee-Ahn

    2018-04-01

    This study investigated the microstructure, tensile and fatigue properties of Al-5 wt.%Mg alloy manufactured by twin roll strip casting. Strips cast as a fabricated (F) specimen and a specimen heat treated (O) at 400 °C/5 h were produced and compared. In the F specimen, microstructural observation discovered clustered precipitates in the center area, while in the O specimen precipitates were relatively more evenly distributed. Al, Al6(Mn, Fe), Mg2Al3 and Mg2Si phases were observed. However, most of the Mg2Al3 phase in the heat-treated O specimen was dissolved. A room temperature tensile test measured yield strength of 177.7 MPa, ultimate tensile strength of 286.1 MPa and elongation of 11.1% in the F specimen and 167.7 MPa (YS), 301.5 MPa (UTS) and 24.6% (EL) in the O specimen. A high cycle fatigue test measured a fatigue limit of 145 MPa in the F specimen and 165 MPa in the O specimen, and the O specimen achieved greater fatigue properties in all fatigue stress conditions. The tensile and fatigue fracture surfaces of the above-mentioned specimens were observed, and this study attempted to investigate the tensile and fatigue deformation behavior of strip cast Al-5 wt.%Mg based on the findings.

  9. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes.

    PubMed

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV.

  10. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes

    PubMed Central

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV. PMID:18924623

  11. Pumping tests in non-uniform aquifers - the linear strip case

    USGS Publications Warehouse

    Butler, J.J.; Liu, W.Z.

    1991-01-01

    Many pumping tests are performed in geologic settings that can be conceptualized as a linear infinite strip of one material embedded in a matrix of differing flow properties. A semi-analytical solution is presented to aid the analysis of drawdown data obtained from pumping tests performed in settings that can be represented by such a conceptual model. Integral transform techniques are employed to obtain a solution in transform space that can be numerically inverted to real space. Examination of the numerically transformed solution reveals several interesting features of flow in this configuration. If the transmissivity of the strip is much higher than that of the matrix, linear and bilinear flow are the primary flow regimes during a pumping test. If the contrast between matrix and strip properties is not as extreme, then radial flow should be the primary flow mechanism. Sensitivity analysis is employed to develop insight into the controls on drawdown in this conceptual model and to demonstrate the importance of temporal and spatial placement of observations. Changes in drawdown are sensitive to the transmissivity of the strip for a limited time duration. After that time, only the total drawdown remains a function of strip transmissivity. In the case of storativity, both the total drawdown and changes in drawdown are sensitive to the storativity of the strip for a time of quite limited duration. After that time, essentially no information can be gained about the storage properties of the strip from drawdown data. An example analysis is performed using data previously presented in the literature to demonstrate the viability of the semi-analytical solution and to illustrate a general procedure for analysis of drawdown data in complex geologic settings. This example reinforces the importance of observation well placement and the time of data collection in constraining parameter correlation, a major source of the uncertainty that arises in the parameter estimation procedure. ?? 1991.

  12. Efficient hybrid evolutionary algorithm for optimization of a strip coiling process

    NASA Astrophysics Data System (ADS)

    Pholdee, Nantiwat; Park, Won-Woong; Kim, Dong-Kyu; Im, Yong-Taek; Bureerat, Sujin; Kwon, Hyuck-Cheol; Chun, Myung-Sik

    2015-04-01

    This article proposes an efficient metaheuristic based on hybridization of teaching-learning-based optimization and differential evolution for optimization to improve the flatness of a strip during a strip coiling process. Differential evolution operators were integrated into the teaching-learning-based optimization with a Latin hypercube sampling technique for generation of an initial population. The objective function was introduced to reduce axial inhomogeneity of the stress distribution and the maximum compressive stress calculated by Love's elastic solution within the thin strip, which may cause an irregular surface profile of the strip during the strip coiling process. The hybrid optimizer and several well-established evolutionary algorithms (EAs) were used to solve the optimization problem. The comparative studies show that the proposed hybrid algorithm outperformed other EAs in terms of convergence rate and consistency. It was found that the proposed hybrid approach was powerful for process optimization, especially with a large-scale design problem.

  13. Comparison of spot tests with AdultaCheck 6 and Intect 7 urine test strips for detecting the presence of adulterants in urine specimens.

    PubMed

    Dasgupta, Amitava; Chughtai, Omar; Hannah, Christina; Davis, Bonnette; Wells, Alice

    2004-10-01

    Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite while "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity check (pH, specific gravity, creatinine and temperature). We previously reported the development of rapid spot tests to detect the presence of these adulterants. AdultaCheck 6 and Intect 7 urine test strips are commercially available for detecting the presence of these adulterants along with specific gravity, creatinine and pH in urine. The performance of these two test strips for detecting adulterants was compared with the results obtained by spot tests. Both AdultaCheck 6 and Intect 7 effectively detected the presence of nitrite and pyridinium chlorochromate in urine. Moreover, both test strips successfully detected the presence of glutaraldehyde, for which no spot test is currently available. High amount of glucose and ascorbic acid did not cause any false positive result with AdultaCheck 6 or Intect 7. Both AdultaCheck 6 and Intect 7 can be used for checking the integrity of a urine specimen submitted for drugs of abuse testing.

  14. 78 FR 13347 - Clinical Chemistry and Clinical Toxicology Devices Panel of the Medical Devices Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    ... as isoniazid test strips. Isoniazid test strips are considered pre-Amendment devices since they were... as methotrexate enzyme immunoassays. Methotrexate enzyme immunoassays are considered pre- Amendment... and PCP radioimmunoassays. PCP enzyme immunoassays and PCP radioimmunoassays are considered pre...

  15. Can Whitening Strips interfere with the Bond Strength of Composite Resins?

    PubMed

    Firoozmand, Leily Macedo; Reis, Washington Luís Machado dos; Vieira, Mercêdes Aroucha; Nunes, Adriana Gomes; Tavarez, Rudys Rodolfo de Jesus; Tonetto, Mateus Rodrigues; Bramante, Fausto Silva; Bhandi, Shilpa H; Roma, Regina Vieira de Oliveira; Bandeca, Matheus Coelho

    2015-04-01

    The aim of this study was to investigate in vitro the bond strength of composite resins on enamel previously treated with whitening strips. A total of 48 bovine incisors were allocated to four experimental groups (n = 12 each): G1 (WSC)- treated with 9.5% hydrogen peroxide whitening strips (3D White Whitestrips® Advanced Vivid/CREST); G2 (WSO)-treated with 10% hydrogen peroxide whitening strips (3D WhiteTM/Oral B); G3 (WG)-treated with 7.5% hydrogen peroxide gel with fluorine, calcium and potassium nitrate (White Class®/FGM); and G4 (C)-control not subjected to bleaching treatment. The specimens were subjected to bleaching over 2 weeks following the manufacturers' instructions. Following the elaboration of the composite resin test specimens, the samples were stored in artificial saliva and subsequently subjected to the micro-shear test using the universal testing machine (EMIC®). The bond strength values were analyzed by one-way ANOVA and Tukey's statistical test (5%). Significant differences were observed among the investigated groups (p < 0.05). The G3-WG exhibited greater values compared with the control group and the groups treated with strips, G1-WSC and G2-WSO. Analysis of the bond interface revealed that a large fraction of the failures occurred at the enamel-resin interface. The bond strength decreased following 14 days of treatment with bleaching strips, whereas the whitening gel with 7.5% hydrogen peroxide, calcium and fluorine increased the bond strength.

  16. An assessment of buffer strips for improving damage tolerance

    NASA Technical Reports Server (NTRS)

    Poe, C. C., Jr.; Kennedy, J. M.

    1981-01-01

    Graphite/epoxy panels with buffer strips were tested in tension to measure their residual strength with crack-like damage. Panels were made with 45/0/-45/90(2S) and 45/0/450(2S) layups. The buffer strips were parallel to the loading directions. They were made by replacing narrow strips of the 0 deg graphite plies with strips of either 0 deg S-Glass/epoxy or Kevlar-49/epoxy on either a one for one or a two for one basis. In a third case, O deg graphite/epoxy was used as the buffer material and thin, perforated Mylar strips were placed between the 0 deg piles and the cross-plies to weaken the interfaces and thus to isolate the 0 deg plies. Some panels were made with buffer strips of different widths and spacings. The buffer strips arrested the cracks and increased the residual strengths significantly over those plain laminates without buffer strips. A shear-lag type stress analysis correctly predicted the effects of layups, buffer material, buffer strip width and spacing, and the number of plies of buffer material.

  17. An assessment of buffer strips for improving damage tolerance of composite laminates

    NASA Technical Reports Server (NTRS)

    Poe, C. C., Jr.; Kennedy, J. M.

    1980-01-01

    Graphite/epoxy panels with buffer strips were tested in tension to measure their residual strength with crack-like damage. Panels were made with (45/0/-45/90)2S and (45/0/-45/0)2S layups. The buffer strips were parallel to the loading direction. They were made by replacing narrow strips of the 0 deg graphite plies with strips of either 0 deg S-Glass/epoxy or Kevlar-90/epoxy on either a one-for-one or a two-for-one basis. In a third case, 0 deg graphite/epoxy was used as the buffer material and thin, perforated Mylar strips were placed between the 0 deg plies and the cross-plies to weaken the interfaces and thus to isolate the 0 deg plies. Some panels were made with buffer strips of different width and spacings. The buffer strips arrested the cracks and increased the residual strengths significantly over those of plain laminates without buffer strips. A shear-lag type stress analysis correctly predicted the effects of layup, buffer material, buffer strip width and spacing, and the number of plies of buffer material

  18. ITCS Test Strip Development and Certification

    NASA Technical Reports Server (NTRS)

    Carrigan, Caitlin; Adam, Niklas; Pickering, Karen; Gazda, Daniel; Piowaty, Hailey

    2011-01-01

    Internal coolant loops used for International Space Station thermal control must be periodically monitored for system health, including pH, biocide levels and any indication of ammonia. The presence of ammonia, possible via a microleak in the interface between the internal and external thermal control systems, could be a danger to the crew. The Internal Thermal Control System (ITCS) Sampling Kit uses test strips as a colorimetric indicator of pH and concentrations of biocide and free ammonia. This paper describes the challenges in designing an ammonia colorimetric indicator in a variable pH environment, as well as lessons learned, ultimately resulting in a robust test strip to indicate a hazardous ammonia leak.

  19. High-sensitivity immunochromatographic assay for fumonisin B1 based on indirect antibody labeling.

    PubMed

    Urusov, Alexandr E; Petrakova, Alina V; Gubaydullina, Milyausha K; Zherdev, Anatoly V; Eremin, Sergei A; Kong, Dezhao; Liu, Liqiang; Xu, Chuanlai; Dzantiev, Boris B

    2017-05-01

    To develop a high-sensitivity immunochromatographic test for fumonisin B1 in plant extracts. Unlike conventional immunochromatographic tests, this assay is performed in two stages: competitive reaction with free specific antibodies and identifying immune complexes by their interaction with the anti-species antibody-conjugated gold nanoparticles. The use of a new geometry for the test strip membranes and a novel reagent application method ensures the proper order of these stages without additional manipulations. The contact of the ready-to-use test strip with the liquid sample suffices in initiating all stages of the assay and obtaining test results. The developed test was used on corn extracts; its instrumental limit of fumonisin B1 detection was 0.6 ng ml -1 at 15 min of assay duration. The proposed approach is flexible and can be used for a wide range of low molecular compounds. The use of anti-species antibody-conjugated gold nanoparticles in immunochromatography significantly facilitates the development of test systems by eliminating the need to synthesize and characterize the conjugates with specific antibodies for each new compound to be detected.

  20. Sole Dependence on Urine Testing Strips and the Ability to Identify Clinically Significant Disease: Challenging the Current Paradigm for Heme Detection in General Clinical Situations.

    PubMed

    Rothschild, Bruce

    2016-05-01

    The ability of health care professionals to provide patient care is potentially compromised when predicated on untested, although longstanding, perspectives. One such example is urinalysis testing, which has been currently simplified to use only urine testing strips for detection of microscopic hematuria. To determine whether urine testing strips are sufficient for identification of clinically significant findings in urinalysis. To determine the presence of microscopic hematuria, I examined a collection of urine specimens that had tested heme negative during the 3-month study period. Of the 342 patients from whom urine specimens were examined during this interval, 50 had microscopic hematuria, despite having tested negative for heme via urine testing strip. Also, 30% were not receiving any medication known to produce microscopic hematuria, and 18% had clinically significant pathology. Diagnosis of significant clinical pathologic manifestations would have been compromised had microscopic examination not been performed on the urine specimens from the cohort individuals. Examination of the novel approach of including microscopic examination of specimens in a specific clinical situation challenges the dominant paradigm of reliance on assaying using urine testing strips only, revealing that the current method is not only unreliable for determining microscopic hematuria but also is less than optimal in general clinical practice. The findings of this study provide evidence of the importance of microscopic evaluation as a routine component of urinalysis. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Stripping-coal deposits on lower Lignite Creek, Nenana coal field, Alaska

    USGS Publications Warehouse

    Wahrhaftig, Clyde; Birman, Joseph H.

    1954-01-01

    Stripping-coal reserves in an area of about 9.4 square miles extending from the Nenana River about 6 miles up the valley of Lignite Creek are estimated to amount to about 95, 000, 000 tons. The stripping-coal reserves are located in the lower and middle members of the Tertiary coal-bearing formation. Five continuous beds in the middle member range in thickness from 5 to 30 feet, and a discontinuous bed at the base of the lower member is about 60 feet thick. Analyses of outcrop samples, as received at the laboratory, show a heating content of 7,500--8,200 Btu, an ash content of 6 to 14 percent, and a moisture content of 25 percent. The reserve estimate is based on a maximum thickness of overburden of 200 feet. Coal below the level of Lignite Creek or its major tributaries was not considered as it was assumed that stripping would be by hydraulic methods. Uncertainties regarding the position of the coal outcrops and the extent of burning of the coal beds are the basis for a recommendation that, where possible, the stripping reserves be tested by drilling. Overburden consists largely of weakly consolidated sandstone and includes some coarse gravel and a few boulders 20 feet or more in diameter. Water for hydraulic mining can be obtained from the Nenana River. Lignite Creek does not appear to be a dependable source. Disposal of debris may affect the channel of the Nenana River causing damage to railroads and structures. Landslides are common in the valley of Lignite Creek and will affect mining operations and transportation routes.

  2. Quantum-Dot-Based Lateral Flow Immunoassay for Detection of Neonicotinoid Residues in Tea Leaves.

    PubMed

    Wang, Shuangjie; Liu, Ying; Jiao, Shasha; Zhao, Ying; Guo, Yirong; Wang, Mengcen; Zhu, Guonian

    2017-11-22

    Neonicotinoid insecticides are commonly used for pest control on tea plantations as a result of their broad-spectrum activity. However, neonicotinoid residues released from tea leaves into tea infusions pose a dietary risk to consumers. Therefore, a rapid, sensitive, and reliable on-site detection method for neonicotinoids is needed. We developed a quantum-dot-based fluorescent lateral flow immunochromatographic strip (LFICS) combined with a broad-specific antibody for detection of typical neonicotinoids (imidacloprid, imidaclothiz, and clothianidin), with sensitivities [50% inhibitory concentration (IC 50 )] of 0.104-0.33 ng/mL and visual detection limits of 0.5-1 ng/mL. The strip assay could be completed in less than 30 min. Using the LFICS to analyze spiked tea samples (green tea, black tea, and oolong tea), the average recovery of the three neonicotinoids ranged between 71 and 111%, with the coefficient of variation below 12%. The results from the LFICS tests for field samples were consistent with results from ultraperformance liquid chromatography-tandem mass spectrometry. The newly developed strip is a useful tool for the on-site detection of neonicotinoid residues in tea.

  3. An Interagency Study of Depainting Techniques

    NASA Technical Reports Server (NTRS)

    Cook, B.

    1997-01-01

    Many popular and widely used paint stripping products now contain methylene chloride as their active ingredient. However, the Environmental Protection Agency (EPA) will critically curb the use of methylene chloride under an aerospace national emission standard for hazardous air pollutants (NESHAP) within the next 2-1/2 years. An effort is underway to identify and evaluate alternative depainting technologies emphasizing those believed to be both effective and environmentally benign. On behalf of the EPA and in cooperation with the U. S. Air Force (USAF), the National Aeronautics and Space Administration (NASA) is conducting a technical assessment of nine alternative technologies (i.e.: chemical stripping, two CO2 blasting processes, FLASHJET(TM) coating removal, laser stripping, plastic media blasting, sodium bicarbonate wet stripping, high-pressure water stripping, and wheat starch blasting). These depainting processes represent five removal method categories, namely abrasive, impact, cryogenic, thermal, and/or molecular bonding dissociation. This paper discusses the test plan and parameters for this interagency study. Several thicknesses of clad and non-clad aluminum substrates were used to prepare test specimens, which have been cut, cleaned, painted, and environmentally aged. Each depainting process has been assigned a specimen lot, which is now undergoing an initial strip cycle. Metallurgical impacts will be determined after these specimens complete five cycles of preparation and stripping.

  4. Woven graphite epoxy composite test specimens with glass buffer strips

    NASA Technical Reports Server (NTRS)

    Bonnar, G. R.; Palmer, R. J.

    1982-01-01

    Woven unidirectional graphite cloth with bands of fiberglass replacing the graphite in discrete lengthwise locations was impregnated with epoxy resin and used to fabricate a series of composite tensile and shear specimens. The finished panels, with the fiberglass buffer strips, were tested. Details of the fabrication process are reported.

  5. New test structures and techniques for measurement of mechanical properties of MEMS materials

    NASA Astrophysics Data System (ADS)

    Sharpe, William N., Jr.; Yuan, Bin; Vaidyanathan, Ranji; Edwards, Richard L.

    1996-09-01

    This paper presents techniques and procedures for addressing the three major problems of mechanical testing of the thin films used in surface micromachined microelectromechanical systems--specimen handling, friction, and strain measurement. The polysilicon tensile specimens are fabricated with two supporting side strips on silicon wafers at the Microelectronic Center of North Carolina. The tensile specimen is released by etching away the wafer, and the two support strips are cut after the specimen is glued in the test machine. Friction is reduced by a linear air bearing in the load train, and strain is measured with a noncontacting technique based on laser interferometry between two gold lines on the tensile specimen. The Young's modulus of polysilicon is 170 +/- 7 GPa and the strength is 1.21 +/- 0.16 GPa from a series of 29 tests. preliminary measurements have been made of Poisson's ratio and the fatigue behavior, and an attempt is underway to measure the fracture toughness.

  6. Effect of at-home whitening strips on the surface roughness and color of a composite and an ormocer restorative material.

    PubMed

    Gurbuz, Ayhan; Ozkan, Pelin; Yilmaz, Kerem; Yilmaz, Burak; Durkan, Rukiye

    2013-01-01

    Oxygenating agents like carbamide peroxide or H(2) O(2) are commonly used whitening agents. They have varying influence on the color and surface roughness of resin-based restorative materials and teeth. The aim of this study was to evaluate the effect of an at-home peroxide whitening agent applied through a whitening strip on the color and surface roughness of a nanofilled composite resin and an ormocer-based resin. Disc-shaped (2 mm thick, 10 mm diameter) nanofilled resin composite (n = 10) and ormocer (n = 10) specimens were prepared. All specimens were treated with a whitening strip. Whitening procedures were performed applying a 6.5% hydrogen peroxide whitening strip (Crest White Strips Professional) for 30 minutes twice each day for a period of 21 consecutive days. During the test intervals, the specimens were rinsed under running distilled water for 1 minute to remove the whitening agents and immersed in 37°C distilled water until the next treatment. Surface roughness and color of the specimens were measured with a profilometer and a colorimeter, respectively, before and after whitening. Color changes were calculated (ΔE) using L*, a*, and b* coordinates. Repeated measures of variance analysis and Duncan test were used for statistical evaluation (α= 0.05). The average surface roughness of composite increased from 1.4 Ra to 2.0 Ra, and from 0.8 Ra to 0.9 Ra for the ormocer material; however, these changes in roughness after whitening were not significant (p > 0.05). Also, when two materials were compared, the surface roughness of restorative materials was not different before and after whitening (p > 0.05). L* and b* values for each material changed significantly after whitening (p < 0.05). ΔE values (before/after whitening) calculated for composite (11.9) and ormocer (16.1) were not significantly different from each other (p > 0.05). The tested whitening agent did not affect the surface roughness of either resin-based restorative material. Both materials became brighter after whitening. The behavior of the materials in the yellow/blue axis was opposite to each other after whitening. Each material had clinically unacceptable color change after whitening (ΔE > 5.5); however, the magnitude of the color change of materials was similar (p > 0.05). According to the results of this study, with the use of materials tested, patients should be advised that existing composite restorations may bleach along with the natural teeth, and replacement of these restorations after whitening may not be required. © 2012 by the American College of Prosthodontists.

  7. Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

    NASA Technical Reports Server (NTRS)

    Bigelow, C. A.

    1988-01-01

    The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

  8. Coupling of PZT Thin Films with Bimetallic Strip Heat Engines for Thermal Energy Harvesting.

    PubMed

    Boughaleb, Jihane; Arnaud, Arthur; Guiffard, Benoit; Guyomar, Daniel; Seveno, Raynald; Monfray, Stéphane; Skotnicki, Thomas; Cottinet, Pierre-Jean

    2018-06-06

    A thermal energy harvester based on a double transduction mechanism and which converts thermal energy into electrical energy by means of piezoelectric membranes and bimetals, has previously been developed and widely presented in the literature In such a device, the thermo-mechanical conversion is ensured by a bimetal whereas the electro-mechanical conversion is generated by a piezoelectric ceramic. However, it has been shown that only 19% of the mechanical energy delivered by the bimetal during its snap is converted into electrical energy. To extract more energy from the bimetallic strip and to increase the transduction efficiency, a new way to couple piezoelectric materials with bimetals has thus been explored through direct deposition of piezoelectric layers on bimetals. This paper consequently presents an alternative way to harvest heat, based on piezoelectric bimetallic strip heat engines and presents a proof of concept of such a system. In this light, different PZT (Lead zirconate titanate) thin films were synthesized directly on aluminium foils and were attached to the bimetals using conductive epoxy. The fabrication process of each sample is presented herein as well as the experimental tests carried out on the devices. Throughout this study, different thicknesses of the piezoelectric layers and substrates were tested to determine the most powerful configuration. Finally, the study also gives some guidelines for future improvements of piezoelectric bimetals.

  9. Issue of Changes in Adhesion of Bitumen Sheet to Primary Layer over the Course of Time in Multilayer Waterproofing during Shear Testing

    NASA Astrophysics Data System (ADS)

    Plachý, Jan; Vysoká, Jana; Vejmelka, Radek; Horský, Jan; Vacek, Vítězslav

    2017-10-01

    This paper is based on research dealing with defects that appear on concrete bridge decks with an insulating layer from asphalt strips on the interface between the asphalt strip and its basis. The durability and lifespan of the bearing structure of concrete bridge is determined by insulating layer that constitutes, together with the primary layer and a protective layer, the insulation system of the concrete bridge deck. Paints based on low viscosity epoxy resigns are one of the possibilities of primary layer implementation. These paints may be performed as anchoring-impregnation paints that usually represent single layer paint on the bridge deck surface. Sealing layer is another variant. Sealing layer is a multilayer consisting of anchoring- impregnation paint and sealing paint. The primary layers mainly provide vapour closing of the concrete surface, and partly, through roughening the surface, contribute to adhesion of bitumen (asphalt) insulation (waterproofing) layer. Application of the primary layer has been spreading in the Czech Republic since the 1990s. Now, after approximately 30 years of use defects in these epoxy based sealing layers at the interface between primary layer and waterproofing layer of reinforced bitumen sheets (RBS) are being solved in the Czech Republic. After performance of the first test focusing on breaking-strength, it was found that the strength between the asphalt and the primary belt layer in some types of low-viscosity resin-epoxy decreases and after a certain period of time again increases, depending on the time. Tensile strength test is carried out on a sample of asphalt strip, which is fused onto the substrate with a primer coat. It was therefore proceeded to test the shear adhesion. Testing of the shear adhesion is conducted on the entire concrete deck waterproofing system. It was supposed that the decrease of adhesion at this test become evident in higher extent. Adhesion tests in shear were performed on the primary layer consisting of an anchoring impregnation coating and sealing layer.

  10. Towards non- and minimally instrumented, microfluidics-based diagnostic devices†

    PubMed Central

    Weigl, Bernhard; Domingo, Gonzalo; LaBarre, Paul; Gerlach, Jay

    2009-01-01

    In many health care settings, it is uneconomical, impractical, or unaffordable to maintain and access a fully equipped diagnostics laboratory. Examples include home health care, developing-country health care, and emergency situations in which first responders are dealing with pandemics or biowarfare agent release. In those settings, fully disposable diagnostic devices that require no instrument support, reagent, or significant training are well suited. Although the only such technology to have found widespread adoption so far is the immunochromatographic rapid assay strip test, microfluidics holds promise to expand the range of assay technologies that can be performed in formats similar to that of a strip test. In this paper, we review progress toward development of disposable, low-cost, easy-to-use microfluidics-based diagnostics that require no instrument at all. We also present examples of microfluidic functional elements—including mixers, separators, and detectors—as well as complete microfluidic devices that function entirely without any moving parts and external power sources. PMID:19023463

  11. Flutter suppression and gust alleviation using active controls

    NASA Technical Reports Server (NTRS)

    Nissim, E.

    1975-01-01

    Application of the aerodynamic energy approach to some problems of flutter suppression and gust alleviation were considered. A simple modification of the control-law is suggested for achieving the required pitch control in the use of a leading edge - trailing edge activated strip. The possible replacement of the leading edge - trailing edge activated strip by a trailing edge - tab strip is also considered as an alternate solution. Parameters affecting the performance of the activated leading edge - trailing edge strip were tested on the Arava STOL Transport and the Westwind Executive Jet Transport and include strip location, control-law gains and a variation in the control-law itself.

  12. Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Dan; Wang, Jun; Wang, Limin

    An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. Themore » proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.« less

  13. Numerical Analysis of Effectiveness of Strengthening Concrete Slab in Tension of the Steel-Concrete Composite Beam Using Pretensioned CFRP Strips

    NASA Astrophysics Data System (ADS)

    Jankowiak, Iwona; Madaj, Arkadiusz

    2017-12-01

    One of the methods to increase the load carrying capacity of the reinforced concrete (RC) structure is its strengthening by using carbon fiber (CFRP) strips. There are two methods of strengthening using CFRP strips - passive method and active method. In the passive method a strip is applied to the concrete surface without initial strains, unlike in the active method a strip is initially pretensioned before its application. In the case of a steel-concrete composite beam, strips may be used to strengthen the concrete slab located in the tension zone (in the parts of beams with negative bending moments). The finite element model has been developed and validated by experimental tests to evaluate the strengthening efficiency of the composite girder with pretensioned CFRP strips applied to concrete slab in its tension zone.

  14. Automated Laser Paint Stripping (ALPS) update

    NASA Astrophysics Data System (ADS)

    Lovoi, Paul

    1993-03-01

    To date, the DoD has played a major role in funding a number of paint stripping programs. Some technologies have proven less effective than contemplated. Others are still in the validation phase. Paint stripping is one of the hottest issues being addressed by the finishing industry since the Environmental Protection Agency (EPA) has mandated that chemical stripping using methylene chloride/phenolic type strippers be stopped. The DoD and commercial aircraft companies are hard-pressed to find an alternative. Automated laser paint stripping has been identified as a technique for removing coatings from aircraft surfaces. International Technical Associates (InTA) was awarded a Navy contract for an automated laser paint stripping system (ALPS) that will remove paint from metallic and composite substrates. For the program, which will validate laser paint stripping, InTA will design, build, test, and install a system for fighter-sized aircraft at both the Norfolk and North Island (San Diego) Aviation Depots.

  15. Design and fabrication of highly sensitive and stable biochip for glucose biosensing

    NASA Astrophysics Data System (ADS)

    Lu, Shi-Yu; Lu, Yao; Jin, Meng; Bao, Shu-Juan; Li, Wan-Yun; Yu, Ling

    2017-11-01

    Common producing steps for test strips is complex and fussy. In this work, we proposed a feasible binder-free test strips fabrication method to directly grow enzyme/manganese phosphate nanosheets hybrids on the screen-print electrodes (SPE). Combined with microfluidic packaging technology, the ready-made portable electrochemical biochip shows a wider linear range (1-40 mM, R2 = 0.9998) and excellent stability (maintained 98% response current after 20 days store and retained 75% response current after continuous 30 days determination) for the detection of glucose. Compared with commercial test strips, the biochip exhibits excellent sensitivity, stability and accuracy, which is indicative of its potential application in real samples.

  16. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    PubMed

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Dual Quantification of Dapivirine and Maraviroc in Cervicovaginal Secretions from Ophthalmic Tear Strips and Polyester-Based Swabs via Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Analysis

    PubMed Central

    Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.

    2014-01-01

    Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. PMID:25005891

  18. 40 CFR 63.11920 - What are my initial and continuous compliance requirements for heat exchange systems?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...

  19. 40 CFR 63.11920 - What are my initial and continuous compliance requirements for heat exchange systems?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...

  20. 40 CFR 63.11920 - What are my initial and continuous compliance requirements for heat exchange systems?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...

  1. Lead-Testing Service to Elementary and Secondary Schools Using Anodic Stripping Voltammetry

    ERIC Educational Resources Information Center

    Goebel, Amanda; Vos, Tracy; Louwagie, Anne; Lundbohm, Laura; Brown, Jay H.

    2004-01-01

    The undergraduate chemistry club of the Southwest Minnesota State University offers assistance in lead-testing through the anodic stripping voltammetry (ASV) technique to elementary and secondary schools. Emphasis is given to this community service activity, which has increased club membership, and promoted discussion of water quality problems in…

  2. Comparison of spot esculin hydrolysis with the PathoTec strip test for rapid differentiation of anaerobic bacteria.

    PubMed Central

    Qadri, S M; Johnson, S; Smith, J C; Zubairi, S; Gillum, R L

    1981-01-01

    The ability of several anaerobic bacteria to hydrolyze esculin to esculetin is used by clinical microbiologists and taxonomists in the differentiation and identification of both gram-positive and gram-negative microorganisms. Conventional methods used for determining esculin hydrolysis by anaerobic bacteria require 24 to 48 h for completion. In this paper we evaluate two procedures which yield rapid results. A total of 738 anaerobic bacteria were used in this study. A total of 99% of the esculin-hydrolyzing anaerobic bacteria gave positive results with the spot test in 1 h, whereas the other test method, the PathoTec strip test (General Diagnostics, Morris Plains, N.J.), required 4 h for 96% of the strains tested to yield positive reactions. Both tests showed a 100% specificity when compared with the standard broth test and are easy to perform, accurate, and economical. The spot test is superior to the PathoTec strip test in yielding results more rapidly. PMID:7016896

  3. Effect of mix parameters on longevity of bituminous mixtures

    NASA Astrophysics Data System (ADS)

    Reichle, Clayton Matthew

    This study was performed to evaluate the effects of varying aggregate sources, aggregate gradations on the stripping and rutting potential of bituminous based plant mixes specified by the Missouri Department of Transportation. The different aggregate combinations included two different aggregate sources (Potosi Dolomite and Jefferson City Dolomite) including two variations for the Jefferson City Dolomite mix to simulate a marginally in-specification mix and an out-of-specification but in-field tolerance mix. The "field" mix simulated the marginal mix where field tolerance of high dust and low binder content were maximized. All three mixes were evaluated for stripping susceptibility using the Tensile Strength Ratio (TSR) test and the Hamburg Wheel Tracking Device (HWTD). The mix characteristics (unit weight, effective binder content, and air voids) were used for a Level 3 analysis in the Mechanistic-Empirical Pavement Design Guide (MEPDG) to determine long term pavement distress conditions such as fatigue cracking, rutting, and IRI (smoothness). The Potosi mix exhibited the best resistance to rutting and stripping during both the TSR testing as well as the Hamburg testing. The Jefferson City In-Spec and Out-of-Spec mixes showed less resistance to rutting and stripping in order, respectively. This was expected for the Jefferson City mixes where the aggregate was of lower quality (higher Los Angeles Abrasion, Micro Deval loss, absorption, and deleterious materials). Also, in the case of the Jefferson City Out-of-Spec mix, the binder content was lower. Upon evaluating the mixes using the MEPDG software, it was shown that mix characteristics such as air voids, VMA, and VFA influenced the fatigue cracking, rutting, and IRI predictions to a minor degree.

  4. Cellular phone-based image acquisition and quantitative ratiometric method for detecting cocaine and benzoylecgonine for biological and forensic applications.

    PubMed

    Cadle, Brian A; Rasmus, Kristin C; Varela, Juan A; Leverich, Leah S; O'Neill, Casey E; Bachtell, Ryan K; Cooper, Donald C

    2010-01-01

    Here we describe the first report of using low-cost cellular or web-based digital cameras to image and quantify standardized rapid immunoassay strips as a new point-of-care diagnostic and forensics tool with health applications. Quantitative ratiometric pixel density analysis (QRPDA) is an automated method requiring end-users to utilize inexpensive (∼ $1 USD/each) immunotest strips, a commonly available web or mobile phone camera or scanner, and internet or cellular service. A model is described whereby a central computer server and freely available IMAGEJ image analysis software records and analyzes the incoming image data with time-stamp and geo-tag information and performs the QRPDA using custom JAVA based macros (http://www.neurocloud.org). To demonstrate QRPDA we developed a standardized method using rapid immunotest strips directed against cocaine and its major metabolite, benzoylecgonine. Images from standardized samples were acquired using several devices, including a mobile phone camera, web cam, and scanner. We performed image analysis of three brands of commercially available dye-conjugated anti-cocaine/benzoylecgonine (COC/BE) antibody test strips in response to three different series of cocaine concentrations ranging from 0.1 to 300 ng/ml and BE concentrations ranging from 0.003 to 0.1 ng/ml. This data was then used to create standard curves to allow quantification of COC/BE in biological samples. Across all devices, QRPDA quantification of COC and BE proved to be a sensitive, economical, and faster alternative to more costly methods, such as gas chromatography-mass spectrometry, tandem mass spectrometry, or high pressure liquid chromatography. The limit of detection was determined to be between 0.1 and 5 ng/ml. To simulate conditions in the field, QRPDA was found to be robust under a variety of image acquisition and testing conditions that varied temperature, lighting, resolution, magnification and concentrations of biological fluid in a sample. To determine the effectiveness of the QRPDA method for quantifying cocaine in biological samples, mice were injected with a sub-locomotor activating dose of cocaine (5 mg/kg; i.p.) and were found to have detectable levels of COC/BE in their urine (160.6 ng/ml) and blood plasma (8.1 ng/ml) after 15-30 minutes. By comparison rats self-administering cocaine in a 4 hour session obtained a final BE blood plasma level of 910 ng/ml with an average of 62.5 infusions. It is concluded that automated QRPDA is a low-cost, rapid and highly sensitive method for the detection of COC/BE with health, forensics, and bioinformatics application and the potential to be used with other rapid immunotest strips directed at several other targets. Thus, this report serves as a general reference and method describing the use of image analysis of lateral flow rapid test strips.

  5. A Community-Based IoT Personalized Wireless Healthcare Solution Trial.

    PubMed

    Catherwood, Philip A; Steele, David; Little, Mike; Mccomb, Stephen; Mclaughlin, James

    2018-01-01

    This paper presents an advanced Internet of Things point-of-care bio-fluid analyzer; a LoRa/Bluetooth-enabled electronic reader for biomedical strip-based diagnostics system for personalized monitoring. We undertake test simulations (technology trial without patient subjects) to demonstrate potential of long-range analysis, using a disposable test 'key' and companion Android app to form a diagnostic platform suitable for remote point-of-care screening for urinary tract infection (UTI). The 868 MHz LoRaWAN-enabled personalized monitor demonstrated sound potential with UTI test results being correctly diagnosed and transmitted to a remote secure cloud server in every case. Tests ranged over distances of 1.1-6.0 Km with radio path losses from 119-141 dB. All tests conducted were correctly and robustly received at the base station and relayed to the secure server for inspection. The UTI test strips were visually inspected for correct diagnosis based on color change and verified as 100% accurate. Results from testing across a number of regions indicate that such an Internet of Things medical solution is a robust and simple way to deliver next generation community-based smart diagnostics and disease management to best benefit patients and clinical staff alike. This significant step can be applied to any type of home or region, particularly those lacking suitable mobile signals, broadband connections, or even landlines. It brings subscription-free long-range bio-telemetry to healthcare providers and offers savings on regular clinician home visits or frequent clinic visits by the chronically ill. This paper highlights practical hurdles in establishing an Internet of Medical Things network, assisting informed deployment of similar future systems.

  6. A Community-Based IoT Personalized Wireless Healthcare Solution Trial

    PubMed Central

    Steele, David; Little, Mike; Mccomb, Stephen; Mclaughlin, James

    2018-01-01

    This paper presents an advanced Internet of Things point-of-care bio-fluid analyzer; a LoRa/Bluetooth-enabled electronic reader for biomedical strip-based diagnostics system for personalized monitoring. We undertake test simulations (technology trial without patient subjects) to demonstrate potential of long-range analysis, using a disposable test ‘key’ and companion Android app to form a diagnostic platform suitable for remote point-of-care screening for urinary tract infection (UTI). The 868 MHz LoRaWAN-enabled personalized monitor demonstrated sound potential with UTI test results being correctly diagnosed and transmitted to a remote secure cloud server in every case. Tests ranged over distances of 1.1–6.0 Km with radio path losses from 119–141 dB. All tests conducted were correctly and robustly received at the base station and relayed to the secure server for inspection. The UTI test strips were visually inspected for correct diagnosis based on color change and verified as 100% accurate. Results from testing across a number of regions indicate that such an Internet of Things medical solution is a robust and simple way to deliver next generation community-based smart diagnostics and disease management to best benefit patients and clinical staff alike. This significant step can be applied to any type of home or region, particularly those lacking suitable mobile signals, broadband connections, or even landlines. It brings subscription-free long-range bio-telemetry to healthcare providers and offers savings on regular clinician home visits or frequent clinic visits by the chronically ill. This paper highlights practical hurdles in establishing an Internet of Medical Things network, assisting informed deployment of similar future systems. PMID:29888145

  7. Post-test evaluation of the geology, geochemistry, microbiology, and hydrology of the in situ air stripping demonstration site at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eddy Dilek, C.A.; Looney, B.B.; Hazen, T.C.

    A full-scale demonstration of the use of horizontal wells for in situ air stripping for environment restoration was completed as part of the Savannah River Integrated Demonstration Program. The demonstration of in situ air stripping was the first in a series of demonstrations of innovative remediation technologies for the cleanup of sites contaminated with volatile organic contaminants. The in situ air stripping system consisted of two directionally drilled wells that delivered gases to and extract contamination from the subsurface. The demonstration was designed to remediate soils and sediments in the unsaturated and saturated zones as well as groundwater contaminated withmore » volatile organic compounds. The demonstration successfully removed significant quantities of solvent from the subsurface. The field site and horizontal wells were subsequently used for an in situ bioremediation demonstration during which methane was added to the injected air. The field conditions documented herein represent the baseline status of the site for evaluating the in situ bioremediation as well as the post-test conditions for the in situ air stripping demonstration. Characterization activities focused on documenting the nature and distribution of contamination in the subsurface. The post-test characterization activities discussed herein include results from the analysis of sediment samples, three-dimensional images of the pretest and post-test data, contaminant inventories estimated from pretest and post-test models, a detailed lithologic cross sections of the site, results of aquifer testing, and measurements of geotechnical parameters of undisturbed core sediments.« less

  8. Comparison of agar dilution and antibiotic gradient strip test with broth microdilution for susceptibility testing of swine Brachyspira species.

    PubMed

    Mirajkar, Nandita S; Gebhart, Connie J

    2016-03-01

    Production-limiting diseases in swine caused by Brachyspira are characterized by mucohemorrhagic diarrhea (B. hyodysenteriae and "B. hampsonii") or mild colitis (B. pilosicoli), while B. murdochii is often isolated from healthy pigs. Emergence of novel pathogenic Brachyspira species and strains with reduced susceptibility to commonly used antimicrobials has reinforced the need for standardized susceptibility testing. Two methods are currently used for Brachyspira susceptibility testing: agar dilution (AD) and broth microdilution (BMD). However, these tests have primarily been used for B. hyodysenteriae and rarely for B. pilosicoli. Information on the use of commercial susceptibility testing products such as antibiotic gradient strips is lacking. Our main objective was to validate and compare the susceptibility results, measured as the minimum inhibitory concentration (MIC), of 6 antimicrobials for 4 Brachyspira species (B. hyodysenteriae, "B. hampsonii", B. pilosicoli, and B. murdochii) by BMD and AD (tiamulin, valnemulin, lincomycin, tylosin, and carbadox) or antibiotic gradient strip (doxycycline) methods. In general, the results of a high percentage of all 4 Brachyspira species differed by ±1 log2 dilution or less by BMD and AD for tiamulin, valnemulin, lincomycin, and tylosin, and by BMD and antibiotic gradient strip for doxycycline. The carbadox MICs obtained by BMD were 1-5 doubling dilutions different than those obtained by AD. BMD for Brachyspira was quicker to perform with less ambiguous interpretation of results when compared with AD and antibiotic gradient strip methods, and the results confirm the utility of BMD in routine diagnostics. © 2016 The Author(s).

  9. Investigation of cladding and coating stripping methods for specialty optical fibers

    NASA Astrophysics Data System (ADS)

    Lee, Jung-Ryul; Dhital, Dipesh; Yoon, Dong-Jin

    2011-03-01

    Fiber optic sensing technology is used extensively in several engineering fields, including smart structures, health and usage monitoring, non-destructive testing, minimum invasive sensing, safety monitoring, and other advanced measurement fields. A general optical fiber consists of a core, cladding, and coating layers. Many sensing principles require that the cladding or coating layer should be removed or modified. In addition, since different sensing systems are needed for different types of optical fibers, it is very important to find and sort out the suitable cladding or coating removal method for a particular fiber. This study focuses on finding the cladding and coating stripping methods for four recent specialty optical fibers, namely: hard polymer-clad fiber, graded-index plastic optical fiber, copper/carbon-coated optical fiber, and aluminum-coated optical fiber. Several methods, including novel laser stripping and conventional chemical and mechanical stripping, were tried to determine the most suitable and efficient technique. Microscopic investigation of the fiber surfaces was used to visually evaluate the mechanical reliability. Optical time domain reflectometric signals of the successful removal cases were investigated to further examine the optical reliability. Based on our results, we describe and summarize the successful and unsuccessful methods.

  10. A design aid for determining width of filter strips

    Treesearch

    M.G. Dosskey; M.J. Helmers; D.E. Eisenhauer

    2008-01-01

    watershed planners need a tool for determining width of filter strips that is accurate enough for developing cost-effective site designs and easy enough to use for making quick determinations on a large number and variety of sites.This study employed the process-based Vegetative Filter Strip Model to evaluate the relationship between filter strip width and trapping...

  11. A portable telescope based on the ALIBAVA system for test beam studies

    NASA Astrophysics Data System (ADS)

    Bernabeu, J.; Casse, G.; Garcia, C.; Greenall, A.; Lacasta, C.; Lozano, M.; Marti-Garcia, S.; Pellegrini, G.; Rodriguez, J.; Ullan, M.; Tsurin, I.

    2013-12-01

    A test beam telescope has been built using the ALIBAVA system to drive its data acquisition. The basic telescope planes consist of four XYT stations. Each station is built from a detector board with two strip sensors, mounted one in each side (strips crossing at 90°). The ensemble is coupled to an ALIBAVA daughter board. These stations act as reference frame and allow a precise track reconstruction. The system is triggered by the coincidence signal of the two scintillators located up and down stream. The telescope can hold several devices under tests. Each ALIBAVA daughter board is linked to its corresponding mother board. The system can hold up to 16 mother boards. A master board synchronizes and controls all the mother boards and collects their data. The off-line analysis software has been developed to study the charge collection, cluster width, tracking efficiency, resolution, etc., of the devices under test. Moreover, the built-in ALIBAVA TDC allows the analysis of the time profile of the device signal. The ALIBAVA telescope has been successfully operated in two test runs at the DESY and CERN-SPS beam lines.

  12. A 3D CZT high resolution detector for x- and gamma-ray astronomy

    NASA Astrophysics Data System (ADS)

    Kuvvetli, I.; Budtz-Jørgensen, C.; Zappettini, A.; Zambelli, N.; Benassi, G.; Kalemci, E.; Caroli, E.; Stephen, J. B.; Auricchio, N.

    2014-07-01

    At DTU Space we have developed a high resolution three dimensional (3D) position sensitive CZT detector for high energy astronomy. The design of the 3D CZT detector is based on the CZT Drift Strip detector principle. The position determination perpendicular to the anode strips is performed using a novel interpolating technique based on the drift strip signals. The position determination in the detector depth direction, is made using the DOI technique based the detector cathode and anode signals. The position determination along the anode strips is made with the help of 10 cathode strips orthogonal to the anode strips. The position resolutions are at low energies dominated by the electronic noise and improve therefore with increased signal to noise ratio as the energy increases. The achievable position resolution at higher energies will however be dominated by the extended spatial distribution of the photon produced ionization charge. The main sources of noise contribution of the drift signals are the leakage current between the strips and the strip capacitance. For the leakage current, we used a metallization process that reduces the leakage current by means of a high resistive thin layer between the drift strip electrodes and CZT detector material. This method was applied to all the proto type detectors and was a very effective method to reduce the surface leakage current between the strips. The proto type detector was recently investigated at the European Synchrotron Radiation Facility, Grenoble which provided a fine 50 × 50 μm2 collimated X-ray beam covering an energy band up to 600 keV. The Beam positions are resolved very well with a ~ 0.2 mm position resolution (FWHM ) at 400 keV in all directions.

  13. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    PubMed

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  14. Design for On-Sun Evaluation of Evaporator Receivers

    NASA Technical Reports Server (NTRS)

    Jaworske, Donald A.; Colozza, Anthony; Sechkar, Edward A.

    2011-01-01

    A heat pipe designed for operation as a solar power receiver should be optimized to accept the solar energy flux and transfer this heat into a reactor. Optical properties of the surface, thermal conductance of the receiver wall, contact resistance of the heat pipe wick, and other heat pipe wick properties ultimately define the maximum amount of power that can be extracted from the concentrated sunlight impinging on the evaporator surface. Modeling of solar power receivers utilizing optical and physical properties provides guidance to their design. On-sun testing is another important means of gathering information on performance. A test rig is being designed and built to conduct on-sun testing. The test rig is incorporating a composite strip mirror concentrator developed as part of a Small Business Innovative Research effort and delivered to NASA Glenn Research Center. In the strip concentrator numerous, lightweight composite parabolic strips of simple curvature were combined to form an array 1.5 m x 1.5 m in size. The line focus of each strip is superimposed in a central area simulating a point of focus. A test stand is currently being developed to hold the parabolic strip concentrator, track the sun, and turn the beam downward towards the ground. The hardware is intended to be sufficiently versatile to accommodate on-sun testing of several receiver concepts, including those incorporating heat pipe evaporators. Characterization devices are also being developed to evaluate the effectiveness of the solar concentrator, including a receiver designed to conduct calorimetry. This paper describes the design and the characterization devices of the on-sun test rig, and the prospect of coupling the concentrated sunlight to a heat pipe solar power receiver developed as part of another Small Business Innovative Research effort.

  15. Development of a highly sensitive lateral immunochromatographic assay for rapid detection of Vibrio parahaemolyticus.

    PubMed

    Liu, Xinfeng; Guan, Yuyao; Cheng, Shiliang; Huang, Yidan; Yan, Qin; Zhang, Jun; Huang, Guanjun; Zheng, Jian; Liu, Tianqiang

    2016-12-01

    Vibrio parahaemolyticus is widely present in brackish water all over the world, causing infections in certain aquatic animals. It is also a foodborne pathogen that causes diarrhea in humans. The aim of this study is to develop an immunochromatographic lateral flow assay (LFA) for rapid detection of V. parahaemolyticus in both aquatic products and human feces of diarrheal patients. Two monoclonal antibody (MAb) pairs, GA1a-IC9 and IC9-KB4c, were developed and proven to be highly specific and sensitive to V. parahaemolyticus. Based on the two MAb pairs, two types of LFA strips were prepared. Their testing limits for V. parahaemolyticus culture were both 1.2×10 3 CFU/ml. The diagnostic sensitivities and specificities were both 100% for the 32 tested microbial species, including 6 Vibrio species. Subsequently, the LFA strips were used to test Whiteleg shrimps and human feces. The type II strip showed a higher diagnostic sensitivity. Its sensitivity and specificity for hepatopancreas and fecal samples from 13 Whiteleg shrimps and fecal samples from 146 human diarrheal patients were all 100%. In conclusion, our homemade type II LFA is a very promising testing device for rapid and convenient detection of V. parahaemolyticus infection not only in aquatic animals, but also in human diarrheal patients. This sensitive immunochromtographic LFA allows rapid detection of V. parahaemolyticus without requirement of culture enrichment. Copyright © 2016. Published by Elsevier B.V.

  16. Lateral flow immunoassay for the rapid detection of citrus tristeza virus

    USDA-ARS?s Scientific Manuscript database

    A lateral flow methodology was developed using gold nanoparticles for rapid detection of Citrus tristeza virus (CTV). The test strip was based on a sandwich immunoassay and could be accomplished within 10 minutes. A sample was considered negative for CTV when only the control line appeared; whereas,...

  17. Roll Casting of Aluminum Alloy Clad Strip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, R.; Tsuge, H.; Haga, T.

    2011-01-17

    Casting of aluminum alloy three layers of clad strip was tried using the two sets of twin roll casters, and effects of the casting parameters on the cladding conditions were investigated. One twin roll caster was mounted on the other twin roll caster. Base strip was 8079 aluminum alloy and overlay strips were 6022 aluminum alloy. Effects of roll-load of upper and lower casters and melt temperature of the lower caster were investigated. When the roll-load of the upper and lower caster was large enough, the overlay strip could be solidified and be connected. The overlay strip could be connectedmore » when the melt of the overlay strip cast by the lower caster was low enough. Sound three layers of clad strip could be cast by proper conditions.« less

  18. Qualification of submerged-arc narrow strip cladding process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayres, P.S.; Gottschling, J.D.; Jeffers, G.K.

    1975-08-01

    An unique narrow strip cladding process for use on both plate and forging material for nuclear components was developed. The qualification testing of this low-heat input process for cladding nuclear components, including those of SA508 Class 2 material is described. The theory that explains the acceptable results of these tests is also given. (auth)

  19. Qualification of submerged-arc narrow strip cladding process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayres, P.S.; Gottschling, J.D.; Jeffers, G.K.

    1976-03-01

    Babcock and Wilcox has developed an unique narrow strip cladding process for use on both plate and forging material for nuclear components. The qualification testing of this low-heat input process for cladding nuclear components is described, including those of SA508 Class 2 material. The theory that explains the acceptable results of these tests is also given.

  20. Strip test for bedside detection of interleukin-6 in cervical secretions is predictive for impending preterm delivery.

    PubMed

    Trébéden, H; Goffinet, F; Kayem, G; Maillard, F; Lemoine, E; Cabrol, D; Weill, B; Batteux, F

    2001-01-01

    Inflammatory cytokines in amniotic fluid are markers of prematurity which could characterize preterm labour of infectious origin. To avoid amniocentesis, we analyzed IL-6, IL-8, IL-10, and IL-13 by RT-PCR in cervical secretions (CS) of 307 women with preterm labour. IL-6 was detected in 26.3% patients who delivered at less than 34 weeks (specificity: 95.8%). In addition, IL-6 was associated with delivery within 7 days (specificity: 91.6%). To render the detection more rapid and cheaper, a strip test was designed and evaluated comparatively with RT-PCR in 76 women. This bedside strip test was twice more sensitive than RT-PCR, with little decrease in specificity.

  1. Innovative and water based stripping approach for thick and bulk photoresists

    NASA Astrophysics Data System (ADS)

    Rudolph, Matthias; Schumann, Dirk; Thrun, Xaver; Esche, Silvio; Hohle, Christoph

    2014-10-01

    The usage of phase fluid based stripping agents to remove photoresists from silicon substrates was studied. Photoresists are required for many silicon based technologies such as MEMS patterning, 3D-Integration or frontend and backend of line semiconductor applications [1]. Although the use of resists is very common, their successful integration often depends on the ability to remove the resist after certain processing steps. On the one hand the resist is changing during subsequent process steps that can cause a thermally activated cross-linking which increases the stripping complexity. Resist removal is also challenging after the formation of a hard polymer surface layer during plasma or implant processes which is called skin or crust [2]. On the other hand the choice of stripping chemistry is often limited due to the presence of functional materials such as metals which can be damaged by aggressive stripping chemistries [3].

  2. A GEM readout with radial zigzag strips and linear charge-sharing response

    DOE PAGES

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; ...

    2018-01-10

    Here, we study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures aremore » implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Lastly, angular resolutions of 60–84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.« less

  3. A GEM readout with radial zigzag strips and linear charge-sharing response

    NASA Astrophysics Data System (ADS)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  4. Occultation Predictions Using CCD Strip-Scanning Astrometry

    NASA Technical Reports Server (NTRS)

    Dunham, Edward W.; Ford, C. H.; Stone, R. P. S.; McDonald, S. W.; Olkin, C. B.; Elliot, J. L.; Witteborn, Fred C. (Technical Monitor)

    1994-01-01

    We are developing the method of CCD strip-scanning astrometry for the purpose of deriving reliable advance predictions for occultations involving small objects in the outer solar system. We are using a camera system based on a Ford/Loral 2Kx2K CCD with the Crossley telescope at Lick Observatory for this work. The columns of die CCD are aligned East-West, the telescope drive is stopped, and the CCD is clocked at the same rate that the stars drift across it. In this way we obtain arbitrary length strip images 20 arcmin wide with 0.58" pixels. Since planets move mainly in RA, it is possible to obtain images of the planet and star to be occulted on the same strip well before the occultation occurs. The strip-to-strip precision (i.e. reproducibility) of positions is limited by atmospheric image motion to about 0.1" rms per strip. However, for objects that are nearby in R.A., the image motion is highly correlated and their relative positions are good to 0.02" rms per strip. We will show that the effects of atmospheric image motion on a given strip can be removed if a sufficient number of strips of a given area have been obtained. Thus, it is possible to reach an rms precision of 0.02" per strip, corresponding to about 0.3 of Pluto or Triton's angular radius. The ultimate accuracy of a prediction based on strip-scanning astrometry is currently limited by the accuracy of the positions of the stars in the astrometric network used and by systematic errors most likely due to the optical system. We will show the results of . the prediction of some recent occultations as examples of the current capabilities and limitations of this technique.

  5. Laboratory accelerated stripping simulator for hot mix asphalt.

    DOT National Transportation Integrated Search

    2005-01-18

    Moisture susceptibility of hot mix asphalt (HMA) pavements continues to be a major pavement distress. Past research : has primarily focused on HMA stripping prevention through material component evaluation/testing and addition of : preventative addit...

  6. Prevention of Stripping under Chip Seals

    DOT National Transportation Integrated Search

    2017-10-01

    Eighteen chip-sealed roadways in eight cities and counties in Minnesota were evaluated both in the field (for condition surveys and density tests) and in the laboratory (for permeability, stripping, tensile-strength ratio, asphalt film thickness, and...

  7. Evaluation of the performance of irradiated silicon strip sensors for the forward detector of the ATLAS Inner Tracker Upgrade

    NASA Astrophysics Data System (ADS)

    Mori, R.; Allport, P. P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Kuczewski, P.; Lynn, D.; Arratia-Munoz, M. I.; Hommels, L. B. A.; Ullan, M.; Fleta, C.; Fernandez-Tejero, J.; Bloch, I.; Gregor, I. M.; Lohwasser, K.; Poley, L.; Tackmann, K.; Trofimov, A.; Yildirim, E.; Hauser, M.; Jakobs, K.; Kuehn, S.; Mahboubi, K.; Parzefall, U.; Clark, A.; Ferrere, D.; Sevilla, S. Gonzalez; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; McMullen, T.; McEwan, F.; O'Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Stastny, J.; Mikestikova, M.; Bevan, A.; Beck, G.; Milke, C.; Domingo, M.; Fadeyev, V.; Galloway, Z.; Hibbard-Lubow, D.; Liang, Z.; Sadrozinski, H. F.-W.; Seiden, A.; To, K.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Jinnouchi, O.; Hara, K.; Sato, K.; Sato, K.; Hagihara, M.; Iwabuchi, S.; Bernabeu, J.; Civera, J. V.; Garcia, C.; Lacasta, C.; Garcia, S. Marti i.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.

    2016-09-01

    The upgrade to the High-Luminosity LHC foreseen in about ten years represents a great challenge for the ATLAS inner tracker and the silicon strip sensors in the forward region. Several strip sensor designs were developed by the ATLAS collaboration and fabricated by Hamamatsu in order to maintain enough performance in terms of charge collection efficiency and its uniformity throughout the active region. Of particular attention, in the case of a stereo-strip sensor, is the area near the sensor edge where shorter strips were ganged to the complete ones. In this work the electrical and charge collection test results on irradiated miniature sensors with forward geometry are presented. Results from charge collection efficiency measurements show that at the maximum expected fluence, the collected charge is roughly halved with respect to the one obtained prior to irradiation. Laser measurements show a good signal uniformity over the sensor. Ganged strips have a similar efficiency as standard strips.

  8. Evaluation of Nobuto filter paper strips for the detection of avian influenza virus antibody in waterfowl

    USGS Publications Warehouse

    Dusek, Robert J.; Hall, Jeffrey S.; Nashold, Sean W.; Teslaa, Joshua L.; Ip, Hon S.

    2011-01-01

    The utility of using Nobuto paper strips for the detection of avian influenza antibodies was examined in mallards (Anas platyrhynchos) experimentally infected with low pathogenic avian influenza viruses. Blood was collected 2 wk after infection and was preserved either as serum or whole blood absorbed onto Nobuto strips. Analysis of samples using a commercially available blocking enzyme-linked immunosorbent assay revealed comparable results (???96% sensitivity for all methods) between sera stored at -30 C and the Nobuto strip preservation method even when the Nobuto strips were stored up to 3 mo at room temperature (RT). Significant differences were detected in the ratio of sample absorbance to negative control absorbance for Nobuto strips stored at RT compared with sera stored at -30 C, although these differences did not affect the ability of the test to reliably detect positive and negative samples. Nobuto strips are a convenient and sensitive alternative to the collection of serum samples when maintaining appropriate storage temperatures is difficult. ?? 2011 American Association of Avian Pathologists.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak

    Here, we study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures aremore » implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Lastly, angular resolutions of 60–84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.« less

  10. Optical microtopographic inspection of the surface of tooth subjected to stripping reduction

    NASA Astrophysics Data System (ADS)

    Costa, Manuel F.; Pereira, Pedro B.

    2011-05-01

    In orthodontics, the decreasing of tooth-size by reducing interproximal enamel surfaces (stripping) of teeth is a common procedure which allows dental alignment with minimal changes in the facial profile and no arch expansion. In order to achieve smooth surfaces, clinicians have been testing various methods and progressively improved this therapeutic technique. In order to evaluate the surface roughness of teeth subject to interproximal reduction through the five most commonly used methods, teeth were inspected by scanning electron microscopy and microtopographically measured using the optical active triangulation based microtopographer MICROTOP.06.MFC. The metrological procedure will be presented as well as the comparative results concluding on the most suitable tooth interproximal reduction method.

  11. Long-term subdural strip electrocorticographic monitoring of ictal déjà vu.

    PubMed

    Weinand, M E; Hermann, B; Wyler, A R; Carter, L P; Oommen, K J; Labiner, D; Ahern, G; Herring, A

    1994-01-01

    We report a series of 8 patients with ictal déjà vu. Subdural strip electrocorticographic (ECoG) monitoring localized the ictal epileptogenic focus as follows: right (n = 6) and left (n = 2) mesiotemporal lobe. In all 8 patients, the left hemisphere was dominant for language function based on intracarotid amytal testing. In 6 right-handed patients, ictal déjà vu was associated with a right temporal lobe focus. However, in the 2 left-handed patients, the ictal focus was left temporal lobe. Although ictal déjà vu localizes the epileptic focus to temporal lobe, this experimental phenomenon appears to lateralize to the hemisphere nondominant for handedness.

  12. Electrochemistry and analytical determination of lysergic acid diethylamide (LSD) via adsorptive stripping voltammetry.

    PubMed

    Merli, Daniele; Zamboni, Daniele; Protti, Stefano; Pesavento, Maria; Profumo, Antonella

    2014-12-01

    Lysergic acid diethylamide (LSD) is hardly detectable and quantifiable in biological samples because of its low active dose. Although several analytical tests are available, routine analysis of this drug is rarely performed. In this article, we report a simple and accurate method for the determination of LSD, based on adsorptive stripping voltammetry in DMF/tetrabutylammonium perchlorate, with a linear range of 1-90 ng L(-1) for deposition times of 50s. LOD of 1.4 ng L(-1) and LOQ of 4.3 ng L(-1) were found. The method can be also applied to biological samples after a simple extraction with 1-chlorobutane. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. You're a good structure, Charlie Brown: the distribution of narrative categories in comic strips.

    PubMed

    Cohn, Neil

    2014-01-01

    Cohn's (2013) theory of "Visual Narrative Grammar" argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3, participants again reconstructed strips but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip and rated that strip's coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. © 2014 Cognitive Science Society, Inc.

  14. Joint EPA/NASA/USAF Interagency Depainting Study

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, M.

    2001-01-01

    Environmental regulations such as National Emission Standards for Hazardous Air Pollutants (NESHAPs) are drivers for the implementation of environmentally compliant methodologies in the manufacture of aerospace hardware. In 1995, the Environmental Protection Agency (EPA) promulgated the NESHAP for the Aerospace Manufacture and Rework (Aerospace NESHAP) industry. Affected facilities were to be in compliance by September 1998. Several aerospace manufacturing operations are regulated within the Aerospace NESHAP including Depainting operations. The National Aeronautics and Space Administration (NASA), EPA, and United States Air Force (USAF) combined resources to evaluate the performance of nine alternative depainting processes. The seven alternative depainting processes were: (1) Chemical stripping (non-methylene chloride); (2) Carbon Dioxide Blasting; (3) Xenon Flashlamp; (4) Carbon Dioxide Laser Stripping; (5) Plastic Media Blasting; (6) Sodium Bicarbonate Wet Stripping; and (7) Waterjet Blasting and Wheat Starch Blasting. All epoxy primer and polyurethane top coat system was applied to 2024-T3 clad and non-clad aluminum test specimens. Approximately 200 test specimens were evaluated in this study. Each coupon was subjected to three, four, or five complete depainting cycles. This paper discusses the conclusions from the study including the test protocol, test parameters, and achievable strip rates for the alternative depainting processes. Test data includes immersion corrosion testing, sandwich corrosion testing and hydrogen embrittlement testing for the non-methylene chloride chemical strippers. Additionally, the cumulative effect of the alternative depainting processes on the metallurgical integrity of the test substrate is addressed with the results from tensile and fatigue evaluations.

  15. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study.

    PubMed

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t -test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation.

  16. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study

    PubMed Central

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    Introduction: There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. Materials and Methods: A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. Results: At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t-test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Conclusion: Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation. PMID:28539864

  17. Audit in a diabetic clinic.

    PubMed

    Child, D F; Williams, C P

    1982-06-01

    Diabetic control was assessed in 82 established insulin-dependent diabetics using a microcapillary system for home preprandial blood glucose sampling. At initial assessment control in the majority (62%) was found to be unsatisfactory (at least 1 preprandial blood glucose greater than 13.0 mmol/l or frequent and severe hypoglycaemia). Sixty-three of these patients were assessed on more than one occasion. Only 24% were satisfactorily controlled at their first assessment, but this proportion had risen to 60% after 12 months. The ability of patients to perform unsupervised blood glucose levels using Ames Glucometers or BM-Glycemie 20-800 test strips was also assessed: 86% of the meter results were within one-third of the laboratory-based results, but there was evidence of bias towards the under-reading of higher glucose values using BM-Glycemie 20-800 test strips. Random blood glucose estimations performed in the diabetic clinic were of little value.

  18. Development and evaluation of a highly sensitive immunochromatographic strip test using gold nanoparticle for direct detection of Vibrio cholerae O139 in seafood samples.

    PubMed

    Pengsuk, Chalinan; Chaivisuthangkura, Parin; Longyant, Siwaporn; Sithigorngul, Paisarn

    2013-04-15

    A strip test for the detection of Vibrio cholerae O139 was developed using two monoclonal antibodies (MAbs), namely VC-273 and VC-812, which specifically bind to the lipopolysaccharide and capsular polysaccharide of V. cholerae O139. The MAb VC-273 gold nanoparticle conjugate was sprayed onto a glass fiber pad that was placed adjacent to a sample chamber. MAb VC-812 and the goat anti-mouse immunoglobulin G (GAM) antibody were sprayed onto a nitrocellulose membrane in strips at positions designated as T and C, respectively. The test strips were assessed for their ability to directly detect V. cholerae O139 using samples dispersed in application buffer, and a 100 μL aliquot of sample was applied to the sample chamber. The results were observable within 20 min after application of the sample. In samples containing V. cholerae O139, the antigen was bound to the colloidal gold-conjugated MAb to form an antibody-antigen complex. This complex was captured by the MAbs at the T test line, resulting in the appearance of a reddish-purple band at the T position. The sensitivity of the test was determined to be 10⁴ cfu mL⁻¹. Direct detection of V. cholerae O139 in various fresh seafood samples could be accomplished with similar sensitivities. The detection limit was substantially improved to 1 cfu mL⁻¹ of the original bacterial content after pre-incubation of the sample in alkaline peptone water for 12 h. The V. cholerae strip test provides several advantages over other methods, including the speed and simplicity of use because there is no requirement for sophisticated equipment. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. An historically consistent and broadly applicable MRV system based on LiDAR sampling and Landsat time-series

    Treesearch

    W. Cohen; H. Andersen; S. Healey; G. Moisen; T. Schroeder; C. Woodall; G. Domke; Z. Yang; S. Stehman; R. Kennedy; C. Woodcock; Z. Zhu; J. Vogelmann; D. Steinwand; C. Huang

    2014-01-01

    The authors are developing a REDD+ MRV system that tests different biomass estimation frameworks and components. Design-based inference from a costly fi eld plot network was compared to sampling with LiDAR strips and a smaller set of plots in combination with Landsat for disturbance monitoring. Biomass estimation uncertainties associated with these different data sets...

  20. Detection of Blood in Stable Flies (Diptera: Muscidae) with Hemoccult® Test Strips

    USDA-ARS?s Scientific Manuscript database

    Hemoccult® test kits were used to detect the remnants of blood meals in stable flies. The strips were able to detect remnants of blood meals in > 90% of the stable flies up to 8 days after blood feeding. This can be compared with detecting blood in the gut visually which was possible in less than 5%...

  1. Results of tree and shrub plantings on low pH strip-mine banks

    Treesearch

    Walter H. Davidson

    1979-01-01

    Test plantings were established to evaluate the survival and growth of trees and shrubs on 10 acid strip mines in the bituminous region of Pennsylvania. Included in the test were five species of European alder, four birch species, black locust, sycamore, Scotch pine, autumn olive, sawtooth oak, bristly locust, and Japanese fleeceflower. After 11 years, data showed that...

  2. Tests of Scintillator+WLS Strips for Muon System at Future Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denisov, Dmitri; Evdokimov, Valery; Lukić, Strahinja

    2015-10-11

    Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

  3. Development of Temporary Rumble Strip Specifications

    DOT National Transportation Integrated Search

    2016-02-01

    The objective of this study was to develop specifications for portable reusable temporary rumble strips for their applications in different work zone settings in Kansas. A detailed literature review, a survey of practice, and a closed-course test wer...

  4. Checking for Ketones

    MedlinePlus

    ... doctor about them as well as record-keeping methods he or she recommends. Most include either packages of strips or foil-wrapped strips (which store longer). Urine tests are simple, but to get good results you have to follow directions carefully. Check ...

  5. Long saphenous vein stripping reduces local level of reactive oxygen metabolites in patients with varicose disease of the lower limbs.

    PubMed

    Flore, Roberto; Santoliquido, Angelo; Antonio, Dal Lago; Pola, Enrico; Flex, Andrea; Pola, Roberto; Muzi, Marco Gallinella; Farinon, Attilio; Rulli, Francesco; Gaetani, Eleonora; Tondi, Paolo; Gerardino, Laura; Gasbarrini, Antonio

    2003-04-01

    Long saphenous vein (LSV) stripping is the most common surgical procedure in patients affected by varicose disease of the lower limbs. Reactive oxygen metabolites (ROM) generation plays a crucial role in chronic venous insufficiency (CVI). The aim of this study was to investigate whether ROM generation is increased in patients affected by varicose disease versus healthy controls and whether LSV stripping has a positive effect on the local production of ROM. The local production of ROM was assessed measuring hydroperoxides in the blood collected from the leg of 30 patients consecutively undergoing LSV stripping and 30 controls. In both the patient group and the control group, the test was repeated 30 days later. We found that ROM levels before surgery are higher in varicose vein patients than in controls ( p <.0001) and that ROM are significantly reduced 30 days after LSV stripping ( p <.0001). At that time point, no significant differences between patients and controls was found. We also found that sex and age do not affect ROM concentration in patients and controls, either before or after surgery. In conclusion, our data indicate that CVI is characterized by significant oxidative stress and that LSV stripping is able to normalize local production of ROM in patients with varicose disease of the lower limbs. We suggest that measurement of ROM might be useful to test the positive effects of LSV stripping in these patients.

  6. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

    PubMed

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G

    2015-03-11

    Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.

  7. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    NASA Astrophysics Data System (ADS)

    Angelico, E.; Seiss, T.; Adams, B.; Elagin, A.; Frisch, H.; Spieglan, E.

    2017-02-01

    We have designed and tested a robust 20×20 cm2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al2O3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm2 array of 2-dimensional square 'pads' with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

  8. Adequate model complexity for scenario analysis of VOC stripping in a trickling filter.

    PubMed

    Vanhooren, H; Verbrugge, T; Boeije, G; Demey, D; Vanrolleghem, P A

    2001-01-01

    Two models describing the stripping of volatile organic contaminants (VOCs) in an industrial trickling filter system are developed. The aim of the models is to investigate the effect of different operating conditions (VOC loads and air flow rates) on the efficiency of VOC stripping and the resulting concentrations in the gas and liquid phases. The first model uses the same principles as the steady-state non-equilibrium activated sludge model Simple Treat, in combination with an existing biofilm model. The second model is a simple mass balance based model only incorporating air and liquid and thus neglecting biofilm effects. In a first approach, the first model was incorporated in a five-layer hydrodynamic model of the trickling filter, using the carrier material design specifications for porosity, water hold-up and specific surface area. A tracer test with lithium was used to validate this approach, and the gas mixing in the filters was studied using continuous CO2 and O2 measurements. With the tracer test results, the biodegradation model was adapted, and it became clear that biodegradation and adsorption to solids can be neglected. On this basis, a simple dynamic mass balance model was built. Simulations with this model reveal that changing the air flow rate in the trickling filter system has little effect on the VOC stripping efficiency at steady state. However, immediately after an air flow rate change, quite high flux and concentration peaks of VOCs can be expected. These phenomena are of major importance for the design of an off-gas treatment facility.

  9. Macro Pixel ASIC (MPA): the readout ASIC for the pixel-strip (PS) module of the CMS outer tracker at HL-LHC

    NASA Astrophysics Data System (ADS)

    Ceresa, D.; Marchioro, A.; Kloukinas, K.; Kaplon, J.; Bialas, W.; Re, V.; Traversi, G.; Gaioni, L.; Ratti, L.

    2014-11-01

    The CMS tracker at HL-LHC is required to provide prompt information on particles with high transverse momentum to the central Level 1 trigger. For this purpose, the innermost part of the outer tracker is based on a combination of a pixelated sensor with a short strip sensor, the so-called Pixel-Strip module (PS). The readout of these sensors is carried out by distinct ASICs, the Strip Sensor ASIC (SSA), for the strip layer, and the Macro Pixel ASIC (MPA) for the pixel layer. The processing of the data directly on the front-end module represents a design challenge due to the large data volume (30720 pixels and 1920 strips per module) and the limited power budget. This is the reason why several studies have been carried out to find the best compromise between ASICs performance and power consumption. This paper describes the current status of the MPA ASIC development where the logic for generating prompt information on particles with high transverse momentum is implemented. An overview of the readout method is presented with particular attention on the cluster reduction, position encoding and momentum discrimination logic. Concerning the architectural studies, a software test bench capable of reading physics Monte-Carlo generated events has been developed and used to validate the MPA design and to evaluate the MPA performance. The MPA-Light is scheduled to be submitted for fabrication this year and will include the full analog functions and a part of the digital logic of the final version in order to qualify the chosen VLSI technology for the analog front-end, the module assembly and the low voltage digital supply.

  10. Subsonic and Supersonic Flutter Analysis of a Highly Tapered Swept-Wing Planform, Including Effects of Density Variation and Finite Wing Thickness, and Comparison with Experiments

    NASA Technical Reports Server (NTRS)

    Yates, Carson, Jr.

    1967-01-01

    The flutter characteristics of several wings with an aspect-ratio of 4.0, a taper ratio of 0.2, and a quarter-chord sweepback of 45 deg. have been investigated analytically for Mach numbers up to 2.0. The calculations were based on the modified-strip-analysis method, the subsonic-kernel-function method, piston theory, and quasi-steady second-order theory. Results of t h e analysis and comparisons with experiment indicated that: (1) Flutter speeds were accurately predicted by the modified strip analysis, although accuracy at t h e highest Mach numbers required the use of nonlinear aerodynamic theory (which accounts for effects of wing thickness) for the calculation of the aerodynamic parameters. (2) An abrupt increase of flutter-speed coefficient with increasing Mach number, observed experimentally in the transonic range, was also indicated by the modified strip analysis. (3) In the low supersonic range for some densities, a discontinuous variation of flutter frequency with Mach number was indicated by the modified strip analysis. An abrupt change of frequency appeared experimentally in the transonic range. (4) Differences in flutter-speed-coefficient levels obtained from tests at low supersonic Mach numbers in two wind tunnels were also predicted by the modified strip analysis and were shown to be caused primarily by differences in mass ratio. (5) Flutter speeds calculated by the subsonic-kernel-function method were in good agreement with experiment and with the results of the modified strip analysis. (6) Flutter speed obtained from piston theory and from quasi-steady second-order theory were higher than experimental values by at least 38 percent.

  11. Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin.

    PubMed

    Hatada, Mika; Tsugawa, Wakako; Kamio, Eri; Loew, Noya; Klonoff, David C; Sode, Koji

    2017-02-15

    Glycated proteins, such as glycated hemoglobin (HbA1c) or glycated albumin (GA) in the blood, are essential indicators of glycemic control for diabetes mellitus. Since GA, compared to HbA1c, is more sensitive to short term changes in glycemic levels, GA is expected to be used as an alternative or together with HbA1c as a surrogate marker indicator for glycemic control. In this paper we report the development of a sensing system for measuring GA by combining an enzyme analysis method, which is already used in clinical practice, with electrochemical principles. We used fructosyl amino acid oxidase, hexaammineruthenium(III) chloride as the electron mediator, and an inexpensive and economically attractive screen-printed carbon electrode. We used chronoamperometry to measure protease-digested GA samples. The developed sensor strips were able to measure protease-digested samples containing GA in very small sample volumes (1.3μL) within about 1min. We also prepared enzyme sensor strips suitable for clinical use in which the enzyme and the mediator were deposited and dried on. This sensor system showed a clear correlation between the GA concentration and the resulting current. The strips were stable following 3 months of storage at 37°C. We conclude that this disposable enzyme sensor strip system for measuring GA is suitable for point-of-care test (POCT) applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Optimization of Stripping Voltammetric Sensor by a Back Propagation Artificial Neural Network for the Accurate Determination of Pb(II) in the Presence of Cd(II).

    PubMed

    Zhao, Guo; Wang, Hui; Liu, Gang; Wang, Zhiqiang

    2016-09-21

    An easy, but effective, method has been proposed to detect and quantify the Pb(II) in the presence of Cd(II) based on a Bi/glassy carbon electrode (Bi/GCE) with the combination of a back propagation artificial neural network (BP-ANN) and square wave anodic stripping voltammetry (SWASV) without further electrode modification. The effects of Cd(II) in different concentrations on stripping responses of Pb(II) was studied. The results indicate that the presence of Cd(II) will reduce the prediction precision of a direct calibration model. Therefore, a two-input and one-output BP-ANN was built for the optimization of a stripping voltammetric sensor, which considering the combined effects of Cd(II) and Pb(II) on the SWASV detection of Pb(II) and establishing the nonlinear relationship between the stripping peak currents of Pb(II) and Cd(II) and the concentration of Pb(II). The key parameters of the BP-ANN and the factors affecting the SWASV detection of Pb(II) were optimized. The prediction performance of direct calibration model and BP-ANN model were tested with regard to the mean absolute error (MAE), root mean square error (RMSE), average relative error (ARE), and correlation coefficient. The results proved that the BP-ANN model exhibited higher prediction accuracy than the direct calibration model. Finally, a real samples analysis was performed to determine trace Pb(II) in some soil specimens with satisfactory results.

  13. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips

    USGS Publications Warehouse

    Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.

    2015-01-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  14. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips.

    PubMed

    Jara, Rocío F; Sepúlveda, Carolina; Ip, Hon S; Samuel, Michael D

    2015-04-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  15. Evaluation of H3A for determination of plant available P vs. FeAIO strips

    USDA-ARS?s Scientific Manuscript database

    Phosphorus is an essential nutrient for plant growth but in excess is a source of environmental pollution. Fertilizer additions of P are recommended based on soil tests; however, the commonly applied P extractants are often applied outside of their design criteria (specifically soil pH). As a resu...

  16. A new extension to the Taste Strips test.

    PubMed

    Wolf, Axel; Illini, Oliver; Uy, Daniel; Renner, Bertold; Mueller, Christian A

    2016-03-01

    Assessment of gustatory function in human subjects using the 'taste strips' test is an easy and validated procedure. The aim of this study was to extend this test in order to detect subjects with superior gustatory sensitivity. The investigation included 134 subjects (29.5±12.6 years, range 18-84 years) with normal gustatory function. Four concentrations of sweet, sour, salty, and bitter were augmented with additional low concentrations (sweet: 25/12.5 mg/ml sucrose; sour: 27/15 mg/ml citric acid; salty: 6.4/2.6 mg/ml sodium chloride, bitter: 0.15/0.06 mg/ml quinine hydrochloride), resulting in a maximum extended taste score (ETS) of 24. The mean ETS was 14.5 ± 3.2. Specifically, it was 4.5 ± 1.2 for sweet, 2.8 ± 1.0 for sour, 4.0 ± 1.3 for salty, and 3.2 ± 1.2 for bitter. In contrast to the original version of the taste strips test, no ceiling effect was observed. Cluster analysis separated three groups of subjects by ETS, whereas test scores derived from the original four concentrations were insufficient to discriminate the subgroup with higher gustatory sensitivity. The extended taste strips test seems to be a useful tool for the detection of patients with low gustatory thresholds for sweet, sour, salty, or bitter taste.

  17. Measurement of Circulating Filarial Antigen Levels in Human Blood with a Point-of-Care Test Strip and a Portable Spectrodensitometer

    PubMed Central

    Chesnais, Cédric B.; Vlaminck, Johnny; Kunyu-Shako, Billy; Pion, Sébastien D.; Awaca-Uvon, Naomi-Pitchouna; Weil, Gary J.; Mumba, Dieudonné; Boussinesq, Michel

    2016-01-01

    The Alere Filariasis Test Strip (FTS) is a qualitative, point-of-care diagnostic tool that detects Wuchereria bancrofti circulating filarial antigen (CFA) in human blood, serum, or plasma. The Global Program to Eliminate Lymphatic Filariasis employs the FTS for mapping filariasis-endemic areas and assessing the success of elimination efforts. The objective of this study was to explore the relationship between the intensity of positive test lines obtained by FTS with CFA levels as determined by enzyme-linked immunosorbent assay (ELISA) with blood and plasma samples from 188 individuals who live in a filariasis-endemic area. The intensity of the FTS test line was assessed visually to provide a semiquantitative score (visual Filariasis Test Strip [vFTS]), and line intensity was measured with a portable spectrodensitometer (quantitative Filariasis Test Strip [qFTS]). These results were compared with antigen levels measured by ELISA in plasma from the same subjects. qFTS measurements were highly correlated with vFTS scores (ρ = 0.94; P < 0.001) and with plasma CFA levels (ρ = 0.91; P < 0.001). Thus, qFTS assessment is a convenient method for quantifying W. bancrofti CFA levels in human blood, which are correlated with adult worm burdens. This tool may be useful for assessing the impact of treatment on adult filarial worms in individuals and communities. PMID:27114288

  18. Stabilometer "S" value comparison using anti-stripping additives.

    DOT National Transportation Integrated Search

    1985-07-01

    from January through July, 1985, asphalt mixes from five construction projects, with and without an anti-stripping additive, were compared for stability. Ten mix samples for each project, at varying asphalt cement content, were prepared and tested in...

  19. Development of Temporary Rumble Strip Specifications : [Technical Summary

    DOT National Transportation Integrated Search

    2016-02-01

    The objective of this study was to develop specifications for portable reusable temporary rumble strips for their applications in different work zone settings in Kansas. A detailed literature review, a survey of practice, and a closed-course test wer...

  20. Closed Course Testing of Portable Rumble Strips to Improve Truck Safety at Work Zones

    DOT National Transportation Integrated Search

    2010-01-01

    The purpose of this research was to compare the attention-getting characteristics, movements and vertical displacements of several portable, reusable rumble strips. The attention-getting characteristics and displacement were measured after passes of ...

  1. A Dual Electrochemical Sensor Based on a Test-strip Assay for the Quantitative Determination of Albumin and Creatinine.

    PubMed

    Yasukawa, Tomoyuki; Kiba, Yuya; Mizutani, Fumio

    2015-01-01

    A dual-electrochemical sensor based on a test-strip assay with immunochemistry and enzyme reactions has been developed for the determination of albumin and creatinine. Each nitrocellulose membrane with an immobilization area of an anti-albumin antibody or three enzymes was prepared in the device with three working electrodes for measuring albumin, creatinine, and ascorbic acid, as well as an Ag/AgCl electrode used as a counter/pseudo-reference electrode. The reactions of three enzymes were initiated by flowing a solution containing creatinine to detect an oxidation current of hydrogen peroxide. A sandwich-type immunocomplex was formed by albumin and antibody labeled with glucose oxidase (GOx). Captured GOx catalyzed the reduction of Fe(CN)6(3-) to Fe(CN)6(4-), which was oxidized electrochemically to determine the captured albumin. The responses for creatinine and albumin increased with the concentrations in millimolar order and over the range 18.75 - 150 μg mL(-1), respectively. The present sensor would be a distinct demonstration for producing quantitative dual-assays for various biomolecules used for clinical diagnoses.

  2. Time and position resolution of the scintillator strips for a muon system at future colliders

    DOE PAGES

    Denisov, Dmitri; Evdokimov, Valery; Lukic, Strahinja

    2016-03-31

    In this study, prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

  3. Performance of a Micro-Strip Gas Chamber for event wise, high rate thermal neutron detection with accurate 2D position determination

    NASA Astrophysics Data System (ADS)

    Mindur, B.; Alimov, S.; Fiutowski, T.; Schulz, C.; Wilpert, T.

    2014-12-01

    A two-dimensional (2D) position sensitive detector for neutron scattering applications based on low-pressure gas amplification and micro-strip technology was built and tested with an innovative readout electronics and data acquisition system. This detector contains a thin solid neutron converter and was developed for time- and thus wavelength-resolved neutron detection in single-event counting mode, which improves the image contrast in comparison with integrating detectors. The prototype detector of a Micro-Strip Gas Chamber (MSGC) was built with a solid natGd/CsI thermal neutron converter for spatial resolutions of about 100 μm and counting rates up to 107 neutrons/s. For attaining very high spatial resolutions and counting rates via micro-strip readout with centre-of-gravity evaluation of the signal amplitude distributions, a fast, channel-wise, self-triggering ASIC was developed. The front-end chips (MSGCROCs), which are very first signal processing components, are read out into powerful ADC-FPGA boards for on-line data processing and thereafter via Gigabit Ethernet link into the data receiving PC. The workstation PC is controlled by a modular, high performance dedicated software suite. Such a fast and accurate system is crucial for efficient radiography/tomography, diffraction or imaging applications based on high flux thermal neutron beam. In this paper a brief description of the detector concept with its operation principles, readout electronics requirements and design together with the signals processing stages performed in hardware and software are presented. In more detail the neutron test beam conditions and measurement results are reported. The focus of this paper is on the system integration, two dimensional spatial resolution, the time resolution of the readout system and the imaging capabilities of the overall setup. The detection efficiency of the detector prototype is estimated as well.

  4. Reynolds Number Effects at High Angles of Attack

    NASA Technical Reports Server (NTRS)

    Fisher, David F.; Cobleigh, Brent R.; Banks, Daniel W.; Hall, Robert M.; Wahls, Richard A.

    1998-01-01

    Lessons learned from comparisons between ground-based tests and flight measurements for the high-angle-of-attack programs on the F-18 High Alpha Research Vehicle (HARV), the X-29 forward-swept wing aircraft, and the X-31 enhanced fighter maneuverability aircraft are presented. On all three vehicles, Reynolds number effects were evident on the forebodies at high angles of attack. The correlation between flight and wind tunnel forebody pressure distributions for the F-18 HARV were improved by using twin longitudinal grit strips on the forebody of the wind-tunnel model. Pressure distributions obtained on the X-29 wind-tunnel model at flight Reynolds numbers showed excellent correlation with the flight data up to alpha = 50 deg. Above (alpha = 50 deg. the pressure distributions for both flight and wind tunnel became asymmetric and showed poorer agreement, possibly because of the different surface finish of the model and aircraft. The detrimental effect of a very sharp nose apex was demonstrated on the X-31 aircraft. Grit strips on the forebody of the X-31 reduced the randomness but increased the magnitude of the asymmetry. Nose strakes were required to reduce the forebody yawing moment asymmetries and the grit strips on the flight test noseboom improved the aircraft handling qualities.

  5. Construction and performance of a silicon photomultiplier/extruded scintillator tail-catcher and muon-tracker

    NASA Astrophysics Data System (ADS)

    Adloff, C.; Blaha, J.; Blaising, J.-J.; Drancourt, C.; Espargilière, A.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Prast, J.; Vouters, G.; Bilki, B.; Francis, K.; Repond, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S. T.; Sosebee, M.; White, A. P.; Yu, J.; Buanes, T.; Eigen, G.; Mikami, Y.; Watson, N. K.; Mavromanolakis, G.; Thomson, M. A.; Ward, D. R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Benyamna, M.; Cârloganu, C.; Fehr, F.; Gay, P.; Manen, S.; Royer, L.; Blazey, G. C.; Boona, S.; Chakraborty, D.; Dyshkant, A.; Hedin, D.; Lima, J. G. R.; Powell, J.; Rykalin, V.; Scurti, N.; Smith, M.; Tran, N.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; Cornett, U.; David, D.; Dietrich, J.; Falley, G.; Gadow, K.; Göttlicher, P.; Günter, C.; Hermberg, B.; Karstensen, S.; Krivan, F.; Lucaci-Timoce, A.-I.; Lu, S.; Lutz, B.; Marchesini, I.; Morozov, S.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Vargas-Trevino, A.; Feege, N.; Garutti, E.; Eckert, P.; Kaplan, A.; Schultz-Coulon, H.-Ch; Shen, W.; Stamen, R.; Tadday, A.; Norbeck, E.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Uozumi, S.; Dauncey, P. D.; Magnan, A.-M.; Bartsch, V.; Wing, M.; Salvatore, F.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Rusinov, V.; Tarkovsky, E.; Kirikova, N.; Kozlov, V.; Soloviev, Y.; Buzhan, P.; Dolgoshein, B.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Smirnov, S.; Frey, A.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Weuste, L.; Bonis, J.; Bouquet, B.; Callier, S.; Cornebise, P.; Doublet, Ph; Dulucq, F.; Faucci Giannelli, M.; Fleury, J.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch; Pöschl, R.; Raux, L.; Seguin-Moreau, N.; Wicek, F.; Anduze, M.; Boudry, V.; Brient, J.-C.; Jeans, D.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Ruan, M.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Takeshita, T.

    2012-04-01

    A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam program, in order to study the possibilities of extending energy sampling behind a hadronic calorimeter and to study the possibilities of providing muon tracking. The ``tail catcher/muon tracker'' (TCMT) is composed of 320 extruded scintillator strips (dimensions 1000 × 50 × 5 mm3) packaged in 16 one-meter square planes interleaved between steel plates. The scintillator strips were read out with wavelength shifting fibers and silicon photomultipliers. The planes were arranged with alternating horizontal and vertical strip orientations. Data were collected for muons and pions in the energy range 6 GeV to 80 GeV. Utilizing data taken in 2006, this paper describes the design and construction of the TCMT, performance characteristics, and a beam-based evaluation of the ability of the TCMT to improve hadronic energy resolution in a prototype ILC detector. For a typical configuration of an ILC detector with a coil situated outside a calorimeter system with a thickness of 5.5 nuclear interaction lengths, a TCMT would improve relative energy resolution by 6-16% for pions between 20 and 80 GeV.

  6. Evaluating the effect of different vegetative filter strip designs on sediment movement in an agricultural watershed using LISEM, Iowa, USA

    NASA Astrophysics Data System (ADS)

    Luquin Oroz, Eduardo; Cruse, Rick; Baartman, Jantiene; Keesstra, Saskia

    2016-04-01

    Although restoration of native vegetation in vulnerable areas would decrease soil loss, this approach is not feasible in communities that base their income on agriculture. However, an alternative exists: strategically placing a small percentage of vegetative filter strips (VFS) within agriculture fields for erosion control. Factors influencing their effectiveness are shallow conditions, vegetation type, filter strip width, slope, soil type, and rainfall characteristics. Generally, the first few meters of the strip are where most sediments deposit. For slopes higher than 10%, effectiveness decreases with increasing slope gradient. Usually, high rainfall intensity and sediment load in overland flow decrease vegetative filter strips' effectiveness. Nowadays, Iowa (USA), experiences increasingly stronger rainstorms; climate change is expected to increase rainfall erosive forces between 16 to 58%. Thus, there is a need to obtain new insights about strip design and its influence on sediment dynamics. Therefore, the objective of this study is to analyze strip design (width) impact on soil and water movement. To do so, different strip widths (no strips, 1.5, 3, 5, 7.5 and 10 meters wide) were analyzed under four rainfall intensities (increments of 10, 25, 50 and 75%) The event-based, hydrological and soil erosion model LISEM was used to simulate different scenarios. The model has been calibrated with data from 3-ha 'Interim 1' watershed, which is part of Walnut Creek (Iowa, USA). During a single event with sediment load, on July 18th 2010, intensities reached up to 80 mm/h. Two different land covers exist: (i) perennial vegetation, which has prairie vegetation covering patches and strips; and (ii) row crop agriculture where corn and soybeans are the main two crops in the area. Based on the different combination of widths and intensities, 24 scenarios were generated. At the moment, the model is on the final part of the calibration; scenario results will be presented on the poster.

  7. Fatigue of graphite/epoxy buffer strip panels with center cracks

    NASA Technical Reports Server (NTRS)

    Bigelow, C. A.

    1985-01-01

    The effects of fatigue loading on the behavior of graphite/epoxy panels with either S-Glass or Kevlar-49 buffer strips is studied. Buffer strip panels are fatigued and tested in tension to measure their residual strength with crack-like damage. Panels are made with 45/0/-45/90 sub 2s layup with either S-Glass or Kevlar-49 buffer strip material. The buffer strips are parallel to the loading direction and made by replacing narrow strips of the 0-degree graphite plies with strips of either 0-degree S-Glass/epoxy or Kevlar-49/epoxy on a one-for-one basis. The panels are subjected to a fatigue loading spectrum MINITWIST, the shortened version of the standardized load program for the wing lower surface of a transport aircraft. Two levels of maximum strain are used in the spectrum with three durations of the fatigue spectrum. One group of panels is preloaded prior to the application of the fatigue cycling. The preload consists of statistically loading the spectrum in tension until the crack-tip damage zone reaches the ajacent buffer strips. After fatigue loading, all specimens are statistically loaded in tension to failure to determine their residual strengths.

  8. Innovative ammonia stripping with an electrolyzed water system as pretreatment of thermally hydrolyzed wasted sludge for anaerobic digestion.

    PubMed

    Park, Seyong; Kim, Moonil

    2015-01-01

    In this study, the anaerobic digestion of thermally hydrolyzed wasted sludge (THWS) with a high concentration of ammonia was carried out through combining with an ammonia stripping and an electrolyzed water system (EWS). The EWS produced acidic water (pH 2-3) at the anode and alkaline water (pH 11-12) at the cathode with an electro-diaphragm between the electrodes that could be applied to ammonia stripping. The ammonia stripping efficiency was strongly dependent on the pH and aeration rate, and the ammonium ion removal rate followed pseudo-first-order kinetics. From the BMP test, the methane yield of THWS after ammonia stripping using the EWS was 2.8 times higher than that of the control process (raw THWS without ammonia stripping). Furthermore, both methane yield and ammonium removal efficiency were higher in this study than in previous studies. Since ammonia stripping with the EWS does not require any chemicals for pH control, no precipitated sludge is produced and anaerobic microorganisms are not inhibited by cations. Therefore, ammonia stripping using the EWS could be an effective method for digestion of wastewater with a high concentration of ammonium nitrogen.

  9. Effect of multi-adhesive layering on retention of extraoral maxillofacial silicone prostheses in vivo.

    PubMed

    Kiat-Amnuay, Sudarat; Gettleman, Lawrence; Goldsmith, L Jane

    2004-09-01

    Loss of retention of maxillofacial prostheses often makes the margin visible or the prosthesis dislodge. Using several medical adhesives in combination may improve retention. The purpose of this study was to investigate the effect of single- and multi-adhesive layering of 2 adhesives on the retention of maxillofacial silicone elastomer strips adhered to the skin of human forearms using a peel test. Power analysis from a previous study and a pilot trial specified at least 20 subjects. Eight Silastic Adhesive A/MDX4-4210 silicone rubber strips (N=240) were applied in a predetermined random order to the left and right ventral forearms of 30 IRB-approved human subjects. Skin-Prep Protective Dressing was applied. Secure 2 Medical Adhesive (SMA) and Epithane-3 (E3) adhesive were used alone or as SMA/E3 or E3/SMA sandwiches (from skin to prosthesis) to adhere strips. Strips were peeled 6 hours later in a universal testing machine at 10 cm/min and data reported in N/m. Paired t tests were used to evaluate left and right arm differences. A Friedman test for nonparametric correlated data with within-subject design was performed, determining differences between both adhesives singly and in combination (alpha=.05). Tests of left-right differences were insignificant ( P =0.43), so the data from both arms were combined. Many strips with E3 did not adhere before testing and were counted as 0 adhesion. Median peel strengths (and 25th and 75th percentiles) in N/m were: SMA = 76.1 (47.1-107), E3 = 6.75 (0.0-25.9), SMA/E3 = 107 (78.0-132), and E3/SMA= 19.6 (6.99-42.4). All 4 variables were significantly different ( P <.0005). The multi-adhesive combination of SMA/E3 had the highest adhesion, followed, in order, by SMA alone, E3/ SMA, and E3 alone. Both E3 groups left a difficult-to-remove residue on the skin. SMA/E3 left a halo-like residue on the skin at the periphery of the strips from the E3 leaking around the SMA. SMA remained adherent to the prosthetic material.

  10. Prototyping of Silicon Strip Detectors for the Inner Tracker of the ALICE Experiment

    NASA Astrophysics Data System (ADS)

    Sokolov, Oleksiy

    2006-04-01

    The ALICE experiment at CERN will study heavy ion collisions at a center-of-mass energy 5.5˜TeV per nucleon. Particle tracking around the interaction region at radii r<45 cm is done by the Inner Tracking System (ITS), consisting of six cylindrical layers of silicon detectors. The outer two layers of the ITS use double-sided silicon strip detectors. This thesis focuses on testing of these detectors and performance studies of the detector module prototypes at the beam test. Silicon strip detector layers will require about 20 thousand HAL25 front-end readout chips and about 3.5 thousand hybrids each containing 6 HAL25 chips. During the assembly procedure, chips are bonded on a patterned TAB aluminium microcables which connect to all the chip input and output pads, and then the chips are assembled on the hybrids. Bonding failures at the chip or hybrid level may either render the component non-functional or deteriorate its the performance such that it can not be used for the module production. After each bonding operation, the component testing is done to reject the non-functional or poorly performing chips and hybrids. The LabView-controlled test station for this operation has been built at Utrecht University and was successfully used for mass production acceptance tests of chips and hybrids at three production labs. The functionality of the chip registers, bonding quality and analogue functionality of the chips and hybrids are addressed in the test. The test routines were optimized to minimize the testing time to make sure that testing is not a bottleneck of the mass production. For testing of complete modules the laser scanning station with 1060 nm diode laser has been assembled at Utrecht University. The testing method relies of the fact that a response of the detector module to a short collimated laser beam pulse resembles a response to a minimum ionizing particle. A small beam spot size (˜7 μm ) allows to deposit the charge in a narrow region and measure the response of individual detector channels. First several module prototypes have been studied with this setup, the strip gain and charge sharing function have been measured, the later is compared with the model predictions. It was also shown that for a laser beam of a high monochromaticity, interference in the sensor bulk significantly modulates the deposited charge and introduces a systematic error of the gain measurement. Signatures of disconnected strips and pinholes defects have been observed, the response of the disconnected strips to the laser beam has been correlated with the noise measurements. Beam test of four prototype modules have been carried out at PS accelerator at CERN using 7 GeV/c pions. It was demonstrated that the modules provide an excellent signal-to-noise ratio in the range 40-75. The estimated spatial resolution for the normally incident tracks is about 18 μm using the center-of-gravity cluster reconstruction method. A non-iterative method for spatial resolution determination was developed, it was shown that in order to determine the resolution of each individual detector in the telescope, the telescope should consist of at least 5 detectors. The detectors showed high detection efficiency, in the order 99%. It was shown that the particle loss occurs mostly in the defected regions near the noisy strips or strips with a very low gain. The efficiency of the sensor area with nominal characteristics is consistent with 100%.

  11. Extraction-Scrub-Strip test results from the interim Salt Disposition Program Macrobatch 9 Tank 21H qualification samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T.

    2016-02-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs)) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used atmore » the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model« less

  12. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    PubMed

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).

  13. Extraction, -scrub, -strip test results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modularmore » Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.« less

  14. Stratum corneum integrity as a predictor for peristomal skin problems in ostomates.

    PubMed

    Nybaek, H; Lophagen, S; Karlsmark, T; Bang Knudsen, D; Jemec, G B E

    2010-02-01

    Peristomal skin problems are common, most often the result is disruption of the skin barrier and this may account for more than one in three visits to ostomy nurses. Therefore a specific assessment of individual risk factors relating to the skin barrier function would be of great interest. Skin barrier integrity in ostomy patients with peristomal skin problems (PSP) was compared with that of ostomy patients with normal skin (controls) using transepidermal water loss (TEWL). Mechanical barrier disruption was determined by a tape stripping test and chemical barrier disruption [sodium lauryl sulphate (SLS) 0.25%]. Patients and controls had a highly significant increase in TEWL value in the peristomal area compared with nonperistomal contralateral abdominal skin (P < 0.0001 for both groups). The skin barrier of normal-looking contralateral skin of ostomates was found to be borderline impaired in patients with PSP compared with those without. A linear association was seen between the number of tape strips removed and TEWL for both cases and controls. Tape stripping suggested that patients with PSP had less resilient skin (P = 0.002). A significant difference in TEWL value between cases and controls was also seen for the SLS patch test on the dorsal skin (P = 0.02). Successive tape stripping, a situation analogous to the normal use of a pouching system, caused a higher degree of barrier damage more rapidly in patients with PSP, indicating an impaired mechanical quality of the barrier. The SLS exposure test suggested a generally increased susceptibility to irritant dermatitis as assessed by TEWL. Our findings suggest tape stripping and SLS testing may have a role as predictive tests to identify patients at risk of PSP.

  15. NASA/Air Force/Environmental Protection Agency Interagency Depainting Study

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia

    1998-01-01

    Many popular and widely used paint stripping products have traditionally contained methylene chloride as their main active ingredient. However, the Environmental Protection Agency (EPA) has critically curved the allowable use of methylene chloride under the National Emission Standard for Hazardous Air Pollutants regulating Aerospace Manufacturing and Rework Facilities . Compliance with this rule was mandatory by September 1998 for affected facilities. An effort is underway to identify and evaluate alternative depainting technologies emphasizing those believed both effective and environmentally benign. On behalf of the EPA and in cooperation with the United States Air Force, the National Aeronautics and Space Administration is conducting a technical assessment of several alternative technologies ( i.e. : chemical stripping, two CO2 blasting processes, CO2 xenon lamp coating removal, CO2 Laser stripping, plastic media blasting, sodium bicarbonate wet stripping, high pressure water stripping, and wheat starch blasting). These depainting processes represent five removal method categories, namely abrasive, impact, cryogenic, thermal, and/or molecular bonding dissociation. This paper discusses the test plan and parameters for this interagency study. Several thicknesses of clad and non-clad aluminum substrates were used to prepare test specimens. Each depainting process has been assigned a specimen lot, all of which have completed three to five stripping cycles. Numerous metallurgical evaluations are underway to assess the impact of these alternative depainting processes upon the structural integrity of the substrate.

  16. Clinical performance of the TRUE2go blood glucose system--a novel integrated system for meter and strips.

    PubMed

    Kipnes, Mark S; Joseph, Hal; Morris, Harry; Manko, Jason; Bell, Douglas E

    2009-10-01

    The complications of diabetes may be minimized by adequate glycemic control, which is aided by self-monitoring of blood glucose (SMBG) levels. A new SMBG system, TRUE2go (Home Diagnostics, Inc., Fort Lauderdale, FL), does not require calibration of test strips, thereby eliminating the potential source of error in blood glucose determination associated with mis-calibration. This study tested the performance of the TRUE2go system. The very small size and attachment of the meter to a vial of test strips make the TRUE2go system unique. The studies were carried out with adult patients with type 1 or 2 diabetes, using procedures for testing accuracy as specified in International Organization for Standardization (ISO) 15197:2003. The evaluation included patients' compliance with the TRUE2go system's written instructions, ease of understanding the supplied instructions, and ease of use of the system. The study demonstrated the accuracy and precision of the TRUE2go system, with 100% of glucose test results falling within ISO-recommended limits for glucose concentrations ranging from 24 mg/dL to 549 mg/dL. There was agreement between data obtained with TRUE2go when used by healthcare professionals and by lay users on capillary blood from both fingertip and a forearm sticks. Lay users' understanding of and compliance with TRUE2go system instructions were excellent, as was their satisfaction with the system. The TRUE2go system is accurate and convenient to use, and its instructions are easily understood by lay users. TRUE2go features that contribute to convenience, and therefore could improve compliance with monitoring regimens, include its small size, attachment to the vial of strips, easy-to-read display, automatic calibration for test strips, and suitability for fingertip as well as forearm testing.

  17. Effect of permethrin impregnated plastic strips on Dermanyssus gallinae in loose-housing systems for laying hens.

    PubMed

    Nordenfors, H; Höglund, J; Tauson, R; Chirico, J

    2001-12-03

    The effect of permethrin impregnated plastic strips (Die No Mite Strips) was evaluated on Dermanyssus gallinae populations in aviary systems for layers in Sweden. Two application strategies of the strips were tested: (A) attached in the housing system, allowing the birds to rub against the strips and thereby get the acaricide released onto their plumage, and (B) attached out of reach of the hens, at two different sites (perches and egg-belt lids) of the inner surfaces of the system, where the mites sheltered during the day. On two farms with 2030 (A) and 3384 (B) hens, and existing mite populations, strips were mounted for 20 and 10 weeks, respectively, and mite numbers were monitored by traps. With application A an overall mite reduction of 53% was observed, while with B the mean mite numbers decreased by 39% at the perches and 92% at the egg-belt lid. The strips were originally designed for caged hens afflicted by ectoparasites that stay on the host for most of their life cycle. However, since D. gallinae spends most of its time off the host, it was not possible to control the parasite with application A. Resistance tests performed on mites from both treated and control compartments where application A was used showed no indication of resistance to permethrin, while 95% of the mites survived a 48 h exposure to the compound where application B was performed. Thus, permethrin resistant mites appeared to be the main reason for the failure to control D. gallinae with application B.

  18. Studies on fast triggering and high precision tracking with Resistive Plate Chambers

    NASA Astrophysics Data System (ADS)

    Aielli, G.; Ball, R.; Bilki, B.; Chapman, J. W.; Cardarelli, R.; Dai, T.; Diehl, E.; Dubbert, J.; Ferretti, C.; Feng, H.; Francis, K.; Guan, L.; Han, L.; Hou, S.; Levin, D.; Li, B.; Liu, L.; Paolozzi, L.; Repond, J.; Roloff, J.; Santonico, R.; Song, H. Y.; Wang, X. L.; Wu, Y.; Xia, L.; Xu, L.; Zhao, T.; Zhao, Z.; Zhou, B.; Zhu, J.

    2013-06-01

    We report on studies of fast triggering and high precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV/c muon beam at CERN using glass RPCs with gas gaps of 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 μm using charge information and 287 μm only using signal arrival time information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.

  19. Carbon dioxide stripping in aquaculture -- part III: model verification

    USGS Publications Warehouse

    Colt, John; Watten, Barnaby; Pfeiffer, Tim

    2012-01-01

    Based on conventional mass transfer models developed for oxygen, the use of the non-linear ASCE method, 2-point method, and one parameter linear-regression method were evaluated for carbon dioxide stripping data. For values of KLaCO2 < approximately 1.5/h, the 2-point or ASCE method are a good fit to experimental data, but the fit breaks down at higher values of KLaCO2. How to correct KLaCO2 for gas phase enrichment remains to be determined. The one-parameter linear regression model was used to vary the C*CO2 over the test, but it did not result in a better fit to the experimental data when compared to the ASCE or fixed C*CO2 assumptions.

  20. Laboratory and field performance of silane anti-strip agent

    DOT National Transportation Integrated Search

    1986-11-01

    A previous ADOT research project resulted in strong evidence that the use of organo-silane as an asphalt additive was very effective in preventing stripping in asphalt concrete pavements. A test section approximately 2800 ft long and 12 ft wide incor...

  1. Stripping in HMA Mixtures: State of the Art and Critical Review of Test Methods

    DOT National Transportation Integrated Search

    1988-09-01

    This report presents review summaries of the state-of-the-art regarding stripping in hot mix asphalt (HMA) mixtures. The review stresses efforts concerned with methods development, evaluation and presents a critical review of select methods including...

  2. Stripping in HMA mixtures : state-of-the-art and critical review of test methods

    DOT National Transportation Integrated Search

    1988-09-01

    This report presents review summaries of the state-of-the-art : regarding stripping in hot mix asphalt (HMA) mixtures. The review stresses efforts concerned with methods development, evaluation and presents a critical review of select methods includi...

  3. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    PubMed

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  4. Validity of HydraTrend reagent strips for the assessment of hydration status.

    PubMed

    Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T

    2014-09-01

    Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p < 0.01) and between reagent strips and pH meter for pH (rs(82) = 0.939, p < 0.01). It was observed that false negative results for National Collegiate Athletic Association (NCAA) requirements (fail refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.

  5. [Evaluation of preexposed step wedges in acceptance tests of film processing in mammography].

    PubMed

    Blendl, C

    2003-03-01

    It was tested with 5 different types of mammography films in which manner the values of "Lightspeed" (LS) and "Lightcontrast" (LC), according DIN V 6868-55 will be changed, when preexposed film strips are used, stored at different climates and spaces of time in comparison to strips, which are exposed immediately before processing. It was proved, that the value LS of preexposed film strips in general will be lowered with increasing storage time compared to freshly exposed film strips, when both strips are processed simultaneously. This drift will be enhanced with increasing rel.humidity levels during storage. The value of LC increases in general with longer storage time and higher rel.humidity levels. The tested film types have all individual drifts in LS and LC. The precision of a single measurement using preexposed film strips was established over all different types of films at in about: Delta LS=0.06 and Delta LC (%)=16% [in the borders of 2 sigma (sigma)]. This uncertainty includes solely the precision of sensitometer, densitometer, the method to establish sensitometric values and unavoidable statistical fluctuations. Even when the systematic drift of the used film type is well established, the required precision, restricted to the listed items and prescribed in DIN V 6868-55, table D.1 to determine the values of LS with Delta LS=0.039 and the values of LC with Delta LC=7.2% is overstepped in so far, that it is impossible to draw a precise conclusion from the measured values to the performance of the subsystem film and processing. If any exceeding of the dose in image receptor plane is monitored, there is no tracking possible to a misadjustment of the subsystem film and processing.

  6. Nanoparticle-Based Immunochromatographic Test Strip with Fluorescent Detector for Quantification of Phosphorylated Acetycholinesterase: An Exposure Biomarker of Organophosphorous Agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Weiying; Ge, Xiaoxiao; Tang, Yong

    A nanoparticle-based fluorescence immunochromatographic test strip (FITS) coupled with a hand-held detector for highly selective and sensitive detection of phosphorylated acetylcholinesterase (AChE), an exposure biomarker of organophosphate (OP) pesticides and nerve agents, is reported. In this approach, OP-AChE adducts were selectively captured by quantum dot-tagged anti-AChE antibodies (Qdot-anti-AChE) and zirconia nanoparticles (ZrO2 NPs). The sandwich-like immunoreactions were performed among the Qdot-anti-AChE, OP-AChE and ZrO2 NPs to form Qdot-anti-AChE/OP-AChE/ZrO2 complex, which was detected by recording the fluorescence intensity of Qdot captured on the test line. Paraoxon was used as the model OP pesticides. Under optimal conditions, this portable FITS immunosensor demonstratesmore » a highly linear absorption response over the range of 0.01 nM to 10 nM OP-AChE, with a detection limit of 4 pM, coupled with a good reproducibility. Moreover, the FITS immunosensor has been validated with OP-AChE spiked human plasma samples. This is the first report on the development of ZrO2 NPs-based FITS for detection of OP-AChE adduct. The FITS immunosensor provides a sensitive and low-cost sensing platform for on-site screening/evaluating OP pesticides and nerve agents poisoning.« less

  7. Measuring Collective Intelligence in Human-Machine Systems

    DTIC Science & Technology

    2013-12-09

    addition, the Doonesbury comic strip on July 15, 2012, was based on the results of our research (see http://doonesbury. slate.com/strip/archive/2012/07/15...The comic strip includes one "error" in its summary of our research results. The Doonesbury character says that "Group IQ doesn’t correlate with... comic strip correspond very closely to the actual results of our research as published in Science magazine. Other honors include: (a) Malone

  8. Efficient content-based low-altitude images correlated network and strips reconstruction

    NASA Astrophysics Data System (ADS)

    He, Haiqing; You, Qi; Chen, Xiaoyong

    2017-01-01

    The manual intervention method is widely used to reconstruct strips for further aerial triangulation in low-altitude photogrammetry. Clearly the method for fully automatic photogrammetric data processing is not an expected way. In this paper, we explore a content-based approach without manual intervention or external information for strips reconstruction. Feature descriptors in the local spatial patterns are extracted by SIFT to construct vocabulary tree, in which these features are encoded in terms of TF-IDF numerical statistical algorithm to generate new representation for each low-altitude image. Then images correlated network is reconstructed by similarity measure, image matching and geometric graph theory. Finally, strips are reconstructed automatically by tracing straight lines and growing adjacent images gradually. Experimental results show that the proposed approach is highly effective in automatically rearranging strips of lowaltitude images and can provide rough relative orientation for further aerial triangulation.

  9. Comparative Study on the Efficacy of Gingival Retraction using Polyvinyl Acetate Strips and Conventional Retraction Cord - An in Vivo Study.

    PubMed

    Shivasakthy, M; Asharaf Ali, Syed

    2013-10-01

    A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. RESULTS were analyzed statistically using Paired students t-test. The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Merocel strip produces more gingival displacement than the conventional retraction cord.

  10. Comparative Study on the Efficacy of Gingival Retraction using Polyvinyl Acetate Strips and Conventional Retraction Cord – An in Vivo Study

    PubMed Central

    Shivasakthy, M.; Asharaf Ali, Syed

    2013-01-01

    Statement of Problem: A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. Purpose of the Study: This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Material and Methods: Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. Results were analyzed statistically using Paired students t-test. Results: The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Conclusion: Merocel strip produces more gingival displacement than the conventional retraction cord. PMID:24298531

  11. Fracture and crack growth in orthotropic laminates

    NASA Technical Reports Server (NTRS)

    Goree, James G.; Kaw, Autar K.

    1985-01-01

    A mathematical model based on the classical shear-lag assumptions is used to study the residual strength and fracture behavior of composite laminates with symmetrically placed buffer strips. The laminate is loaded by a uniform remote longitudinal tensile strain and has initial damage in the form of a transverse crack in the parent laminate between buffer strips. The crack growth behavior as a function of material properties, number of buffer-strip plies, spacing, width of buffer strips, longitudinal matrix splitting, and debonding at the interface is studied. Buffer-strip laminates are shown to arrest fracture and increase the residual strengths significantly over those of one material laminates, with S-glass being a more effective buffer strip material than Kevlar in increasing the damage tolerance of graphite/epoxy panels. For a typical graphite/epoxy laminate with S-glass buffer-strips, the residual strength is about 2.4 times the residual strength of an all graphite/epoxy panel with the same crack length. Approximately 50% of this increase is due to the S-glass/epoxy buffer-strips, 40% due to longitudinal splitting of the buffer strip interface and 10% due to bonding.

  12. Scaling effects of a graphene field effect transistor for radiation detection

    NASA Astrophysics Data System (ADS)

    Shollar, Zachary Frank

    Radiation detectors based on graphene is a burgeoning research topic within the immense field of graphene research. Although papers continue to parse out their mysteries, the devices remain simplistic and small. New fabrication techniques have allowed for millimeter scale and larger monolayer graphene sheets to be grown with increasingly better quality. It is the goal of this thesis to investigate the scaling effects of millimeter scale graphene for radiation detection purposes. To this end, chemical vapor deposition grown monolayer graphene was purchased and transferred to Si/SiO2 substrates. The devices were patterned into simple rectangular strips varying in size from 3000 x 500 mum, 600 x 100 mum, 300 x 50 mum, and 60 x 11 mum. Four metal contacts were patterned onto each strip for electrical characterization. Two probe resistance measurements were performed on all four sizes, at three different lengths along the graphene. Using the field effect, the graphene resistance response was measured at 0 V back-gate voltage to obtain graphene resistivity on SiO2, which showed an increase in resistivity as the graphene strip size increased. Further, the response was measured for varying back-gate sweep ranges and speeds. This lead to the conclusion that strong p-doping was inherent in the graphene strips, as evidenced by charge neutral points located above +50 V. Strong hysteresis observed in those tests alluded to trapped charge having a major effect on voltage sweeps. Mobility values for the graphene strips were extracted from the back-gate voltage sweeps and fixed gate voltage stabilization curves. Mobility values overall were less than 400 cm2 V-1 s-1, and showed a modest increase in mobility as graphene length increased. Lastly, the largest graphene strip had a light response and radiation response measured. Light response showed a dependence on gate voltage magnitude that favored positive gate voltages, on an n-type Silicon substrate. A saturation effect above +15 V seemed apparent with a resistance increase of only 0.61% +/- 0.062% for +15 V to 0.69% +/- 0.097% for the +50 V back-gate. Response of the largest graphene strip size to forward facing alpha irradiation showed a modest 0.32% +/- 0.082% increase in response, for a -15 V back- gate. Overall, millimeter scale graphene field effect devices showed a light and radiation response, proving their viability. However, results showed fabricated samples had numerous defects and were far from pristine. Fabrication of pristine graphene strips at millimeter scales is of concern. Further work into large scale GFET patterning, testing at more length and width dimensions, and further investigating metal contact and carrier transport in millimeter scales is needed.

  13. Alkaline-side extraction of technetium from tank waste using crown ethers and other extractants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonnesen, P.V.; Moyer, B.A.; Presley, D.J.

    The chemical development of a new crown-ether-based solvent-extraction process for the separation of (Tc) from alkaline tank-waste supernate is ready for counter-current testing. The process addresses a priority need in the proposed cleanup of Hanford and other tank wastes. This need has arisen from concerns due to the volatility of Tc during vitrification, as well as {sup 99}Tc`s long half-life and environmental mobility. The new process offers several key advantages that direct treatability--no adjustment of the waste composition is needed; economical stripping with water; high efficiency--few stages needed; non-RCRA chemicals--no generation of hazardous or mixed wastes; co-extraction of {sup 90}Sr;more » and optional concentration on a resin. A key concept advanced in this work entails the use of tandem techniques: solvent extraction offers high selectivity, while a subsequent column sorption process on the aqueous stripping solution serves to greatly concentrate the Tc. Optionally, the stripping solution can be evaporated to a small volume. Batch tests of the solvent-extraction and stripping components of the process have been conducted on actual melton Valley Storage Tank (MVST) waste as well as simulants of MVST and Hanford waste. The tandem process was demonstrated on MVST waste simulants using the three solvents that were selected the final candidates for the process. The solvents are 0.04 M bis-4,4{prime}(5{prime})[(tert-butyl)cyclohexano]-18-crown-6 (abbreviated di-t-BuCH18C6) in a 1:1 vol/vol blend of tributyl phosphate and Isopar{reg_sign} M (an isoparaffinic kerosene); 0.02 M di-t-BuCH18C6 in 2:1 vol/vol TBP/Isopar M and pure TBP. The process is now ready for counter-current testing on actual Hanford tank supernates.« less

  14. First experience with carbon stripping foils for the 160 MeV H- injection into the CERN PSB

    NASA Astrophysics Data System (ADS)

    Weterings, Wim; Bracco, Chiara; Jorat, Louise; Noulibos, Remy; van Trappen, Pieter

    2018-05-01

    160 MeV H- beam will be delivered from the new CERN linear accelerator (Linac4) to the Proton Synchrotron Booster (PSB), using a H- charge-exchange injection system. A 200 µg/cm2 carbon stripping foil will convert H- into protons by stripping off the electrons. The H- charge-exchange injection principle will be used for the first time in the CERN accelerator complex and involves many challenges. In order to gain experience with the foil changing mechanism and the very fragile foils, in 2016, prior to the installation in the PSB, a stripping foil test stand has been installed in the Linac4 transfer line. In addition, parts of the future PSB injection equipment are also temporarily installed in the Linac4 transfer line for tests with a 160 MeV H- commissioning proton beam. This paper describes the foil changing mechanism and control system, summarizes the practical experience of gluing and handling these foils and reports on the first results with beam.

  15. A plane mirror experiment inspired by a comic strip

    NASA Astrophysics Data System (ADS)

    Lúcio Prados Ribeiro, Jair

    2016-01-01

    A comic strip about a plane mirror was used in a high school optics test, and it was perceived that a large portion of the students believed that the mirror should be larger than the object so the virtual image could be entirely visible. Inspired on the comic strip, an experimental demonstration with flat mirrors was developed, in order to readdress this topic learning. Students were encouraged to create their own investigation of the phenomenon with a simple instrumental apparatus and also suggest different experimental approaches.

  16. Increase in the light collection from a scintillation strip with a hole for the WLS fiber using filling materials of various types

    NASA Astrophysics Data System (ADS)

    Artikov, A. M.; Baranov, V. Yu.; Budagov, J. A.; Glagolev, V. V.; Davydov, Yu. I.; Kolomoets, V. I.; Simonenko, A. V.; Tereschenko, V. V.; Kharzheev, Yu. N.; Chokheli, D.; Shalyugin, A. N.

    2017-01-01

    The light collection of extruded scintillation strip samples with the help of WLS fibers placed in a longitudinal hole inside of the plates has been measured. The holes are filled with various liquid fillers. Measurements are performed under irradiation by cosmic muons. A method for pumping a liquid filler with a viscosity of more than 10 Pa s into the strip hole with a WLS fiber inside is devised and successfully tested.

  17. 76 FR 42681 - Brass Sheet and Strip From Germany: Notice of Rescission of Antidumping Duty Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-19

    ... Germany: Notice of Rescission of Antidumping Duty Administrative Review AGENCY: Import Administration... antidumping duty order on brass sheet and strip from Germany. The review covers one producer/exporter of brass sheet and strip from Germany, Wieland-Werke AG (``Wieland''). Based on a timely withdrawal of the...

  18. Cardiovascular, diabetes, and cancer strips: evidences, mechanisms, and classifications

    PubMed Central

    Wu, Qing-Hua; Hu, Da-Yi

    2014-01-01

    Objectives To report and name firstly that there are cardiovascular disease (CVD), diabetes mellitus (DM) and cancers (CDC) strips; and disclose their mechanisms, classifications, and clinical significances. Study design Narrative and systematic review study and interpretive analysis. Methods Data sources and study selection: to collect and present related evidences on CDC strips from evidence-based, open-access, both Chinese- and English-language literatures in recent 10 years on clinical trials from PubMed according to keywords “CVD, DM and cancers” as well as authors’ extensive clinical experience with the treatment of more than fifty thousands of patients with CVD, diabetes and cancers over the past decades, and analyze their related mechanisms and categories which based on authors’ previous works. Data extraction: data were mainly extracted from 48 articles which are listed in the reference section of this review. Qualitative, quantitative and mixed data were included, narratively and systematically reviewed. Results With several conceptual and technical breakthrough, authors present related evidences on CDC strips, these are, CVD and DM, DM and cancers, cancers and CVD linked, respectively; And “Bad SEED” +/– “bad soil” theory or doctrine may explain this phenomenon due to “internal environmental injure, abnormal or unbalance” in human body resulting from the role of risk factors (RFs) related multi-pathways and multi-targets, which including organ & tissue (e.g., vascular-specific), cell and gene-based mechanisms. Their classifications include main strips/type B, and Branches/type A as showed by tables and figures in this article. Conclusions There are CDC strips and related mechanisms and classifications. CDC strips may help us to understand, prevent, and control related common non-communicable diseases (NCDs) as well as these high risk strips. PMID:25276377

  19. Light-curve and spectral properties of ultra-stripped core-collapse supernovae

    NASA Astrophysics Data System (ADS)

    Moriya, Takashi J.

    2017-11-01

    We discuss light-curve and spectral properties of ultra-stripped core-collapse supernovae. Ultra-stripped supernovae are supernovae with ejecta masses of only ~0.1M ⊙ whose progenitors lose their envelopes due to binary interactions with their compact companion stars. We follow the evolution of an ultra-stripped supernova progenitor until core collapse and perform explosive nucleosynthesis calculations. We then synthesize light curves and spectra of ultra-stripped supernovae based on the nucleosynthesis results. We show that ultra-stripped supernovae synthesize ~0.01M ⊙ of the radioactive 56Ni, and their typical peak luminosity is around 1042 erg s-1 or -16 mag. Their typical rise time is 5 - 10 days. By comparing synthesized and observed spectra, we find that SN 2005ek and some of so-called calcium-rich gap transients like PTF10iuv may be related to ultra-stripped supernovae.

  20. The bacterial contamination rate of glucose meter test strips in the hospital setting

    PubMed Central

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalemci, Emrah

    This work summarizes the efforts in Turkey to build a laboratory capable of building and testing high energy astrophysics detectors that work in space. The EC FP6 ASTRONS project contributed strongly to these efforts, and as a result a fully operational laboratory at Sabanci University have been developed. In this laboratory we test and develop Si and CdZnTe based room temperature semiconductor strip detectors and develop detector and electronics system to be used as a payload on potential small Turkish satellites.

  2. Development of FEB Test Platform for ATLAS New Small Wheel Upgrade

    NASA Astrophysics Data System (ADS)

    Lu, Houbing; Hu, Kun; Wang, Xu; Li, Feng; Han, Liang; Jin, Ge

    2016-10-01

    This concept of test platform is based on the test requirements of the front-end board (FEB) which is developed for the phase I upgrade of the small Thin Gap Chamber(sTGC) detector on New Small Wheel(NSW) of ATLAS. The front-end electronics system of sTGC consists of 1,536 FEBs with about 322,000 readout of strips, wires and pads in total. A test platform for FEB with up to 256 channels has been designed to keep the testing efficiency at a controllable level. We present the circuit model architecture of the platform, and its functions and implementation as well. The firmware based on Field Programmable Gate Array (FPGA) and the software based on PC have been developed, and basic test methods have been established. FEB readout measurements have been performed in analog injection from the test platform, which will provide a fast and efficient test method for the production of FEB.

  3. An aerial survey method to estimate sea otter abundance

    USGS Publications Warehouse

    Bodkin, James L.; Udevitz, Mark S.; Garner, Gerald W.; Amstrup, Steven C.; Laake, Jeffrey L.; Manly, Bryan F.J.; McDonald, Lyman L.; Robertson, Donna G.

    1999-01-01

    Sea otters (Enhydra lutris) occur in shallow coastal habitats and can be highly visible on the sea surface. They generally rest in groups and their detection depends on factors that include sea conditions, viewing platform, observer technique and skill, distance, habitat and group size. While visible on the surface, they are difficult to see while diving and may dive in response to an approaching survey platform. We developed and tested an aerial survey method that uses intensive searches within portions of strip transects to adjust for availability and sightability biases. Correction factors are estimated independently for each survey and observer. In tests of our method using shore-based observers, we estimated detection probabilities of 0.52-0.72 in standard strip-transects and 0.96 in intensive searches. We used the survey method in Prince William Sound, Alaska to estimate a sea otter population size of 9,092 (SE = 1422). The new method represents an improvement over various aspects of previous methods, but additional development and testing will be required prior to its broad application.

  4. Optical pH Sensor Covering the Range from pH 0-14 Compatible with Mobile-Device Readout and Based on a Set of Rationally Designed Indicator Dyes.

    PubMed

    Gotor, Raúl; Ashokkumar, Pichandi; Hecht, Mandy; Keil, Karin; Rurack, Knut

    2017-08-15

    In this work, a family of pH-responsive fluorescent probes has been designed in a rational manner with the aid of quantum chemistry tools, covering the entire pH range from 0-14. Relying on the boron-dipyrromethene (BODIPY) core, all the probes as well as selected reference dyes display very similar spectroscopic properties with ON-OFF fluorescence switching responses, facilitating optical readout in simple devices used for detection and analysis. Embedding of the probes and reference dyes into hydrogel spots on a plastic strip yielded a test strip that reversibly indicates pH with a considerably small uncertainty of ∼0.1 pH units. These strips are not only reusable but, combined with a 3D-printed case that can be attached to a smartphone, the USB port of which drives the integrated LED used for excitation, allows for autonomous operation in on-site or in-the-field applications; the developed Android application software ("app") further simplifies operation for unskilled users.

  5. Immunochromatographic strip assay for detection of bioactive Ganoderma triterpenoid, ganoderic acid A in Ganoderma lingzhi.

    PubMed

    Sakamoto, Seiichi; Kikkawa, Nao; Kohno, Toshitaka; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi

    2016-10-01

    Ganoderic acid A (GAA) is one of the major Ganoderma triterpenes produced by medicinal mushroom belonging to the genus Ganoderma (Ganodermataceae). Due to its interesting pharmacological activities, Ganoderma species have been traditionally used in China for the treatment of various diseases. Herein, we developed a colloidal gold-based immunochromatographic strip assay (ICA) for the rapid detection of GAA using highly specific monoclonal antibody against GAA (MAb 12A) conjugated with gold nanoparticles. Using the developed ICA, the detection of GAA can be completed within 15min after dipping the test strip into an analyte solution with the limit of detection (LOD) for GAA of ~500ng/mL. In addition, this system makes it possible to perform a semi-quantitative analysis of GAA in Ganoderma lingzhi, where high reliability was evaluated by enzyme-linked immunosorbent assay (ELISA). The newly developed ICA can potentially be applied to the standardization of Ganoderma using GAA as an index because GAA is major triterpenoid present much in the mushroom. Copyright © 2016. Published by Elsevier B.V.

  6. Feasibility and Economics Study of the Treatment, Recycling and Disposal of Spent Abrasives

    DTIC Science & Technology

    1999-04-09

    compression, and film stripping. The recycling performance testing plan is summarized in Table 2. (The test plan is discussed in detail in Appendix B: Law...D1188 Yes Yes Immersion Compression ................... ASTM C4867 Yes Yes Film Stripping................................... CalTrans 302 Yes Yes...from 10% to 20% for aluminum oxide abrasives, and 15% to 30% for garnet abrasives. 9 Data Intepretation SSPC-AB 1 requires that the conductivitiy of

  7. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    PubMed

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  8. Rapid detection of multidrug resistant Gram-negative bacilli by Cica-Beta-Test strips.

    PubMed

    Lavigne, J-P; Pfeiffer, C; Vidal, L; Sotto, A

    2011-02-01

    This study aimed to evaluate the sensitivity and specificity of a new system (Cica-Beta-Test, Kanto Chemical, Japan) for rapid detection of AmpC-derepressed, extended-spectrum β-lactamases (ESβL) and metallo-β-lactamases (MβL). Two hundred Multi-Drug Resistant (MDR)-Gram-negative bacilli were studied: 170 Enterobacteriaceae and 30 Gram-negative non-fermentative bacteria. One hundred and eighteen strains produced an ESβL, seven MβL and 75 derepressed cephalosporinases. One drop of substrate was dispensed onto the filter pad of the Cica-Beta-Test strip. The bacterial colonies were spread on the filter pad of strip. The reading was performed after 2 to 15 min: turning chromogenic indicated the positive test. Three tests were used: Cica-Beta I for detection of MDR bacteria; Cica-Beta MβL for detection of MβL-producing bacteria and Cica-Beta CVA, which distinguish ESβL and AmpC-derepressed producers. Results were compared with molecular assays. Cica-Beta-Test I has detected 194 MDR (sensitivity 97%), Cica-Beta-Test MβL has shown the presence of six MβL tested (sensitivity 85.7%). Five strains were non-MβL false positive (specificity 97.3%). Cica-Beta-Test CVA allowed the differentiation of ESβL-producing strains (109/115) and AmpC-derepressed strains (56/67) (sensitivity 94.8%, specificity 83.8%). Because of their epidemic nature, the MDR strains are screened and require strict hygienic measures patients. The simultaneous use of three strips can quickly determine the presence of MDR including ESβL and MβL. Rapid screening of MDR avoids transmission and limits the use of broad-spectrum antibiotics. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  9. A phononic crystal strip based on silicon for support tether applications in silicon-based MEMS resonators and effects of temperature and dopant on its band gap characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ha, Thi Dep, E-mail: hathidep@yahoo.com; Faculty of Electronic Technology, Industrial University of Ho Chi Minh City, Hochiminh City; Bao, JingFu, E-mail: baojingfu@uestc.edu.cn

    Phononic crystals (PnCs) and n-type doped silicon technique have been widely employed in silicon-based MEMS resonators to obtain high quality factor (Q) as well as temperature-induced frequency stability. For the PnCs, their band gaps play an important role in the acoustic wave propagation. Also, the temperature and dopant doped into silicon can cause the change in its material properties such as elastic constants, Young’s modulus. Therefore, in order to design the simultaneous high Q and frequency stability silicon-based MEMS resonators by two these techniques, a careful design should study effects of temperature and dopant on the band gap characteristics tomore » examine the acoustic wave propagation in the PnC. Based on these, this paper presents (1) a proposed silicon-based PnC strip structure for support tether applications in low frequency silicon-based MEMS resonators, (2) influences of temperature and dopant on band gap characteristics of the PnC strips. The simulation results show that the largest band gap can achieve up to 33.56 at 57.59 MHz and increase 1280.13 % (also increase 131.89 % for ratio of the widest gaps) compared with the counterpart without hole. The band gap properties of the PnC strips is insignificantly effected by temperature and electron doping concentration. Also, the quality factor of two designed length extensional mode MEMS resonators with proposed PnC strip based support tethers is up to 1084.59% and 43846.36% over the same resonators with PnC strip without hole and circled corners, respectively. This theoretical study uses the finite element analysis in COMSOL Multiphysics and MATLAB softwares as simulation tools. This findings provides a background in combination of PnC and dopant techniques for high performance silicon-based MEMS resonators as well as PnC-based MEMS devices.« less

  10. Separation and counting of single molecules through nanofluidics, programmable electrophoresis, and nanoelectrode-gated tunneling and dielectric detection

    DOEpatents

    Lee, James W.; Thundat, Thomas G.

    2006-04-25

    An apparatus for carrying out the separation, detection, and/or counting of single molecules at nanometer scale. Molecular separation is achieved by driving single molecules through a microfluidic or nanofluidic medium using programmable and coordinated electric fields. In various embodiments, the fluidic medium is a strip of hydrophilic material on nonconductive hydrophobic surface, a trough produced by parallel strips of hydrophobic nonconductive material on a hydrophilic base, or a covered passageway produced by parallel strips of hydrophobic nonconductive material on a hydrophilic base together with a nonconductive cover on the parallel strips of hydrophobic nonconductive material. The molecules are detected and counted using nanoelectrode-gated electron tunneling methods, dielectric monitoring, and other methods.

  11. Flat Plate Boundary Layer Stimulation Using Trip Wires and Hama Strips

    NASA Astrophysics Data System (ADS)

    Peguero, Charles; Henoch, Charles; Hrubes, James; Fredette, Albert; Roberts, Raymond; Huyer, Stephen

    2017-11-01

    Water tunnel experiments on a flat plate at zero angle of attack were performed to investigate the effect of single roughness elements, i.e., trip wires and Hama strips, on the transition to turbulence. Boundary layer trips are traditionally used in scale model testing to force a boundary layer to transition from laminar to turbulent flow at a single location to aid in scaling of flow characteristics. Several investigations of trip wire effects exist in the literature, but there is a dearth of information regarding the influence of Hama strips on the flat plate boundary layer. The intent of this investigation is to better understand the effects of boundary layer trips, particularly Hama strips, and to investigate the pressure-induced drag of both styles of boundary layer trips. Untripped and tripped boundary layers along a flat plate at a range of flow speeds were characterized with multiple diagnostic measurements in the NUWC/Newport 12-inch water tunnel. A wide range of Hama strip and wire trip thicknesses were used. Measurements included dye flow visualization, direct skin friction and parasitic drag force, boundary layer profiles using LDV, wall shear stress fluctuations using hot film anemometry, and streamwise pressure gradients. Test results will be compared to the CFD and boundary layer model results as well as the existing body of work. Conclusions, resulting in guidance for application of Hama strips in model scale experiments and non-dimensional predictions of pressure drag will be presented.

  12. 77 FR 14493 - Polyethylene Terephthalate Film, Sheet, and Strip From the People's Republic of China: Final...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-12

    ... Film, Sheet, and Strip From the People's Republic of China: Final Results of the 2009-2010 Antidumping... review of polyethylene terephthalate film, sheet, and strip (``PET film'') from the People's Republic of... this review. We invited interested parties to comment on our Preliminary Results. Based on our analysis...

  13. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    PubMed

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    PubMed

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum.

    PubMed

    Dussart, Philippe; Petit, Laure; Labeau, Bhety; Bremand, Laetitia; Leduc, Alexandre; Moua, David; Matheus, Séverine; Baril, Laurence

    2008-08-20

    We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.

  16. A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.

    PubMed

    Di Nardo, F; Anfossi, L; Giovannoli, C; Passini, C; Goftman, V V; Goryacheva, I Y; Baggiani, C

    2016-04-01

    A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to perform the analysis was 22 min, including sample preparation. Recovery values in the range from 91.4% to 105.4% with coefficients of variation not exceeding 5% were obtained for fortified and naturally contaminated maize flour samples. To evaluate the possible improvements due to the use of QD for ICST technology, we performed a direct comparison of the proposed QD-ICST to a gold nanoparticles- and a chemiluminescent-ICST previously developed for fumonisins detection, in which the same immunoreagents were employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Comparison of X-31 Flight and Ground-Based Yawing Moment Asymmetries at High Angles of Attack

    NASA Technical Reports Server (NTRS)

    Cobleigh, Brent R.; Croom, Mark A.

    2001-01-01

    Significant yawing moment asymmetries were encountered during the high-angle-of-attack envelope expansion of the two X-31 aircraft. These asymmetries caused position saturations of the thrust-vectoring vanes and trailing-edge flaps during some stability-axis rolling maneuvers at high angles of attack. The two test aircraft had different asymmetry characteristics, and ship two has asymmetries that vary as a function of Reynolds number. Several aerodynamic modifications have been made to the X-31 forebody with the goal of minimizing the asymmetry. These modifications include adding transition strips on the forebody and noseboom, using two different length strakes, and increasing nose bluntness. Ultimately, a combination of forebody strakes, nose blunting, and noseboom transition strips reduced the yawing moment asymmetry enough to fully expand the high-angle-of-attack envelope. Analysis of the X-31 flight data is reviewed and compared to wind-tunnel and water-tunnel measurements. Several lessons learned are outlined regarding high-angle-of-attack configuration design and ground testing.

  18. Friction evaluation of unpaved, gypsum-surface runways at Northrup Strip, White Sands Missile Range, in support of Space Shuttle Orbiter landing and retrieval operations

    NASA Technical Reports Server (NTRS)

    Yager, T. J.; Horne, W. B.

    1980-01-01

    Friction measurement results obtained on the gypsum surface runways at Northrup Strip, White Sands Missile Range, N. M., using an instrumented tire test vehicle and a diagonal braked vehicle, are presented. These runways were prepared to serve as backup landing and retrieval sites to the primary sites located at Dryden Flight Research Center for shuttle orbiter during initial test flights. Similar friction data obtained on paved and other unpaved surfaces was shown for comparison and to indicate that the friction capability measured on the dry gypsum surface runways is sufficient for operations with the shuttle orbiter and the Boeing 747 aircraft. Based on these ground vehicle friction measurements, estimates of shuttle orbiter and aircraft tire friction performance are presented and discussed. General observations concerning the gypsum surface characteristics are also included and several recommendations are made for improving and maintaining adequate surface friction capabilities prior to the first shuttle orbiter landing.

  19. Plasmonic colorimetric sensors based on etching and growth of noble metal nanoparticles: Strategies and applications.

    PubMed

    Zhang, Zhiyang; Wang, Han; Chen, Zhaopeng; Wang, Xiaoyan; Choo, Jaebum; Chen, Lingxin

    2018-08-30

    Plasmonic colorimetric sensors have emerged as a powerful tool in chemical and biological sensing applications due to the localized surface plasmon resonance (LSPR) extinction in the visible range. Among the plasmonic sensors, the most famous sensing mode is the "aggregation" plasmonic colorimetric sensor which is based on plasmon coupling due to nanoparticle aggregation. Herein, this review focuses on the newly-developing plasmonic colorimetric sensing mode - the etching or the growth of metal nanoparticles induces plasmon changes, namely, "non-aggregation" plasmonic colorimetric sensor. This type of sensors has attracted increasing interest because of their exciting properties of high sensitivity, multi-color changes, and applicability to make a test strip. Of particular interest, the test strip by immobilization of nanoparticles on the substrate can avoid the influence of nanoparticle auto-aggregation and increase the simplicity in storage and use. Although there are many excellent reviews available that describe the advance of plasmonic sensors, limited attention has been paid to the plasmonic colorimetric sensors based on etching or growth of metal nanoparticles. This review highlights recent progress on strategies and application of "non-aggregation" plasmonic colorimetric sensors. We also provide some personal insights into current challenges associated with "non-aggregation" plasmonic colorimetric sensors and propose future research directions. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Immunochromatographic strip assay for the rapid and sensitive detection of Salmonella Typhimurium in artificially contaminated tomato samples.

    PubMed

    Shukla, Shruti; Leem, Hyerim; Lee, Jong-Suk; Kim, Myunghee

    2014-06-01

    This study was designed to confirm the applicability of a liposome-based immunochromatographic assay for the rapid detection of Salmonella enterica subsp. enterica serovar Typhimurium (Salmonella Typhimurium) in artificially contaminated tomato samples. To determine the detection limit and pre-enrichment incubation time (10, 12, and 18 h pre-enrichment in 1% buffered peptone water), the tests were performed with different cell numbers of Salmonella Typhimurium (3 × 10(0), 3 × 10(1), 3 × 10(2), and 3 × 10(3) CFU·mL(-1)) inoculated into 25 g of crushed tomato samples. The assay was able to detect as few as 30 Salmonella Typhimurium cells per 25 g of tomato samples (1.2 cells·g(-1)) after 12 h pre-enrichment incubation. Moreover, when the developed assay was compared with traditional morphological and biochemical culture-based methods as well as colloidal gold nanoparticle-based commercial test strips, the developed assay yielded positive results for the detection of Salmonella Typhimurium within a shorter period time. These findings confirm that the developed assay may have practical application for the sensitive detection of Salmonella Typhimurium in various food samples, including raw vegetables, with a relatively low detection limit and shorter analysis time.

  1. Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.

    ERIC Educational Resources Information Center

    Diamond, Philip

    A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…

  2. Reduced posting and marking of flight progress strips for en route air traffic control : final report.

    DOT National Transportation Integrated Search

    2000-02-01

    The new Display System Replacement (DSR) being implemented in air route traffic control centers (ARTCCs) will allow the data-side controller less room to post Flight Progress Strips (FPSs). We tested a new FPS marking and posting procedure designed t...

  3. A hybrid skull-stripping algorithm based on adaptive balloon snake models

    NASA Astrophysics Data System (ADS)

    Liu, Hung-Ting; Sheu, Tony W. H.; Chang, Herng-Hua

    2013-02-01

    Skull-stripping is one of the most important preprocessing steps in neuroimage analysis. We proposed a hybrid algorithm based on an adaptive balloon snake model to handle this challenging task. The proposed framework consists of two stages: first, the fuzzy possibilistic c-means (FPCM) is used for voxel clustering, which provides a labeled image for the snake contour initialization. In the second stage, the contour is initialized outside the brain surface based on the FPCM result and evolves under the guidance of the balloon snake model, which drives the contour with an adaptive inward normal force to capture the boundary of the brain. The similarity indices indicate that our method outperformed the BSE and BET methods in skull-stripping the MR image volumes in the IBSR data set. Experimental results show the effectiveness of this new scheme and potential applications in a wide variety of skull-stripping applications.

  4. Comparative In Vitro Efficacy of Doripenem and Imipenem Against Multi-Drug Resistant Pseudomonas aeruginosa.

    PubMed

    Wali, Nadia; Mirza, Irfan Ali

    2016-04-01

    To compare the in vitro efficacy of doripenem and imipenem against multi-drug resistant (MDR) Pseudomonas aeruginosa from various clinical specimens. Descriptive cross-sectional study. Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from November 2012 to November 2013. MDR Pseudomonas aeruginosa isolates from various clinical samples were included in the study. Susceptibility of Pseudomonas aeruginosa against doripenem and imipenem was performed by E-test strip and agar dilution methods. The results were interpreted as recommended by Clinical Laboratory Standard Institute (CLSI) guidelines. The maximum number of Pseudomonas aeruginosa were isolated from pure pus and pus swabs. In vitro efficacy of doripenem was found to be more effective as compared to imipenem against MDR Pseudomonas aeruginosa with both E-test strip and agar dilution methods. Overall, p-values of 0.014 and 0.037 were observed when susceptibility patterns of doripenem and imipenem were evaluated with E-test strip and agar dilution methods. In vitro efficacy of doripenem was found to be better against MDR Pseudomonas aeruginosaas compared to imipenem when tested by both E-test and agar dilution methods.

  5. Single Photon Counting Large Format Imaging Sensors with High Spatial and Temporal Resolution

    NASA Astrophysics Data System (ADS)

    Siegmund, O. H. W.; Ertley, C.; Vallerga, J. V.; Cremer, T.; Craven, C. A.; Lyashenko, A.; Minot, M. J.

    High time resolution astronomical and remote sensing applications have been addressed with microchannel plate based imaging, photon time tagging detector sealed tube schemes. These are being realized with the advent of cross strip readout techniques with high performance encoding electronics and atomic layer deposited (ALD) microchannel plate technologies. Sealed tube devices up to 20 cm square have now been successfully implemented with sub nanosecond timing and imaging. The objective is to provide sensors with large areas (25 cm2 to 400 cm2) with spatial resolutions of <20 μm FWHM and timing resolutions of <100 ps for dynamic imaging. New high efficiency photocathodes for the visible regime are discussed, which also allow response down below 150nm for UV sensing. Borosilicate MCPs are providing high performance, and when processed with ALD techniques are providing order of magnitude lifetime improvements and enhanced photocathode stability. New developments include UV/visible photocathodes, ALD MCPs, and high resolution cross strip anodes for 100 mm detectors. Tests with 50 mm format cross strip readouts suitable for Planacon devices show spatial resolutions better than 20 μm FWHM, with good image linearity while using low gain ( 106). Current cross strip encoding electronics can accommodate event rates of >5 MHz and event timing accuracy of 100 ps. High-performance ASIC versions of these electronics are in development with better event rate, power and mass suitable for spaceflight instruments.

  6. Evaluation of vaginal pH for detection of bacterial vaginosis

    PubMed Central

    Hemalatha, R.; Ramalaxmi, Baru Anantha; Swetha, Eluru; Balakrishna, N.; Mastromarino, Paola

    2013-01-01

    Background & objectives: Bacterial vaginosis (BV) is highly prevalent among women in reproductive age group. Little information exists on routine vaginal pH measurement in women with BV. We undertook this study to assess the utility of vaginal pH determination for initial evaluation of bacterial vaginosis. Methods: In this cross-sectional study vaginal swabs were collected from women with complaints of white discharge, back ache and pain abdomen attending a government hospital and a community health clinic, and subjected to vaginal pH determination, Gram stain, wet mount and whiff test. Nugent score and Amsel criteria were used for BV confirmation. Results: Of the 270 women included in the analysis, 154 had BV based on Nugents’ score. The mean vaginal pH in women with BV measured by pH strips and pH glove was 5 and 4.9, respectively. The vaginal pH was significantly higher in women with BV. Vaginal discharge was prevalent in 84.8 per cent women, however, only 56.8 per cent of these actually had BV by Nugent score (NS). Presence of clue cells and positive whiff test were significant for BV. Vaginal pH >4.5 by pH strips and pH Glove had a sensitivity of 72 and 79 per cent and specificity of 60 and 53 per cent, respectively to detect BV. Among the combination criteria, clue cells and glove pH >4.5 had highest sensitivity and specificity to detect BV. Interpretation & conclusions: Vaginal pH determination is relatively sensitive, but less specific in detecting women with BV. Inclusion of whiff test along with pH test reduced the sensitivity, but improved specificity. Both, the pH strip and pH glove are equally suitable for screening women with BV on outpatient basis. PMID:24135180

  7. Prototyping of petalets for the Phase-II upgrade of the silicon strip tracking detector of the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Kuehn, S.; Benítez, V.; Fernández-Tejero, J.; Fleta, C.; Lozano, M.; Ullán, M.; Lacker, H.; Rehnisch, L.; Sperlich, D.; Ariza, D.; Bloch, I.; Díez, S.; Gregor, I.; Keller, J.; Lohwasser, K.; Poley, L.; Prahl, V.; Zakharchuk, N.; Hauser, M.; Jakobs, K.; Mahboubi, K.; Mori, R.; Parzefall, U.; Bernabéu, J.; Lacasta, C.; Marco-Hernandez, R.; Rodriguez Rodriguez, D.; Santoyo, D.; Solaz Contell, C.; Soldevila Serrano, U.; Affolder, T.; Greenall, A.; Gallop, B.; Phillips, P. W.; Cindro, V.

    2018-03-01

    In the high luminosity era of the Large Hadron Collider, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and exploits the concept of modularity. Prototyping and testing of various strip detector components has been carried out. This paper presents the developments and results obtained with reduced-size structures equivalent to those foreseen to be used in the forward region of the silicon strip detector. Referred to as petalets, these structures are built around a composite sandwich with embedded cooling pipes and electrical tapes for routing the signals and power. Detector modules built using electronic flex boards and silicon strip sensors are glued on both the front and back side surfaces of the carbon structure. Details are given on the assembly, testing and evaluation of several petalets. Measurement results of both mechanical and electrical quantities are shown. Moreover, an outlook is given for improved prototyping plans for large structures.

  8. Simultaneous stripping recovery of ammonia-nitrogen and precipitation of manganese from electrolytic manganese residue by air under calcium oxide assist.

    PubMed

    Chen, Hongliang; Liu, Renlong; Shu, Jiancheng; Li, Wensheng

    2015-01-01

    Leaching tests of electrolytic manganese residue (EMR) indicated that high contents of soluble manganese and ammonia-nitrogen posed a high environmental risk. This work reports the results of simultaneous stripping recovery of ammonia-nitrogen and precipitation of manganese by air under calcium oxide assist. The ammonia-nitrogen stripping rate increased with the dosage of CaO, the air flow rate and the temperature of EMR slurry. Stripped ammonia-nitrogen was absorbed by a solution of sulfuric acid and formed soluble (NH4)2SO4 and (NH4)3H(SO4)3. The major parameters that effected soluble manganese precipitation were the dosage of added CaO and the slurry temperature. Considering these two aspects, the efficient operation conditions should be conducted with 8 wt.% added CaO, 60°C, 800 mL min(-1) air flow rate and 60-min reaction time. Under these conditions 99.99% of the soluble manganese was precipitated as Mn3O4, which was confirmed by XRD and SEM-EDS analyses. In addition, the stripping rate of ammonia-nitrogen was 99.73%. Leaching tests showed the leached toxic substances concentrations of the treated EMR met the integrated wastewater discharge standard of China (GB8978-1996).

  9. Simple questionnaire and urine reagent strips compared to microscopy for the diagnosis of Schistosoma haematobium in a community in northern Ghana.

    PubMed

    Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg

    2012-10-01

    To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.

  10. Maturation of human embryonic stem cell-derived cardiomyocytes (hESC-CMs) in 3D collagen matrix: Effects of niche cell supplementation and mechanical stimulation.

    PubMed

    Zhang, W; Kong, C W; Tong, M H; Chooi, W H; Huang, N; Li, R A; Chan, B P

    2017-02-01

    Cardiomyocytes derived from human embryonic stem cells (hESC-CMs) are regarded as a promising source for regenerative medicine, drug testing and disease modeling. Nevertheless, cardiomyocytes are immature in terms of their contractile structure, metabolism and electrophysiological properties. Here, we fabricate cardiac muscle strips by encapsulating hESC-CMs in collagen-based biomaterials. Supplementation of niche cells at 3% to the number of hESC-CMs enhance the maturation of the hESC-CMs in 3D tissue matrix. The benefits of adding mesenchymal stem cells (MSCs) are comparable to that of adding fibroblasts. These two cell types demonstrate similar effects in promoting the compaction and cell spreading, as well as expression of maturation markers at both gene and protein levels. Mechanical loading, particularly cyclic stretch, produces engineered cardiac tissues with higher maturity in terms of twitch force, elastic modulus, sarcomere length and molecular signature, when comparing to static stretch or non-stretched controls. The current study demonstrates that the application of niche cells and mechanical stretch both stimulate the maturation of hESC-CMs in 3D architecture. Our results therefore suggest that this 3D model can be used for in vitro cardiac maturation study. Cardiomyocytes derived from human embryonic stem cells (hESC-CMs) are regarded as being a promising source of cells for regenerative medicine, drug testing and disease modeling. Nevertheless, cardiomyocytes are immature in terms of their contractile structure, metabolism and electrophysiological properties. In the current study, we have fabricated cardiac muscle strips by encapsulating hESC-CMs in collagen-based biomaterials and demonstrated that supplementation of mesenchymal niche cells as well as provision of mechanical loading particularly stretching have significantly promoted the maturation of the cardiomyocytes and hence improved the mechanical functional characteristics of the tissue strips. Specifically, with 3% niche cells including both fibroblasts and mesenchymal stem cells, a more mature hESC-CMs derived cardiac strip was resulted, in terms of compaction and spreading of cells, and upregulation of molecular signature in both gene and protein expression of maturation. Mechanical loading, particularly cyclic stretch, produces engineered cardiac tissues with higher maturity in terms of molecular signature markers and functional parameters including twitch force, elastic modulus and sarcomere length, when comparing with static stretch or non-stretched controls. The current study demonstrates that the application of niche cells and mechanical stretch both stimulate the maturation of hESC-CMs in 3D architecture, resulting in more mature cardiac strips. Our results contribute to bioengineering of functional heart tissue strips for drug screening and disease modeling. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Reliable Method for Assessing Seed Germination, Dormancy, and Mortality under Field Conditions.

    PubMed

    Pace, Brian A; Alexander, Helen M; Emry, D Jason; Mercer, Kristin L

    2016-11-06

    We describe techniques for approximating seed bank dynamics over time using Helianthus annuus as an example study species. Strips of permeable polyester fabric and glue can be folded and glued to construct a strip of compartments that house seeds and identifying information, while allowing contact with soil leachate, water, microorganisms, and ambient temperature. Strips may be constructed with a wide range of compartment numbers and sizes and allow the researcher to house a variety of genotypes within a single species, different species, or seeds that have experienced different treatments. As opposed to individual seed packets, strips are more easily retrieved as a unit. While replicate packets can be included within a strip, different strips can act as blocks or can be retrieved at different times for observation of seed behavior over time. We used a high temperature glue gun to delineate compartments and sealed the strips once the seed and tags identifying block and removal times were inserted. The seed strips were then buried in the field at the desired depth, with the location marked for later removal. Burrowing animal predators were effectively excluded by use of a covering of metal mesh hardware cloth on the soil surface. After the selected time interval for burial, strips were dug up and seeds were assessed for germination, dormancy and mortality. While clearly dead seeds can often be distinguished from ungerminated living ones by eye, dormant seeds were conclusively identified using a standard Tetrazolium chloride colorimetric test for seed viability.

  12. Distillation and Air Stripping Designs for the Lunar Surface

    NASA Technical Reports Server (NTRS)

    Boul, Peter J.; Lange, Kevin E.; Conger, Bruce; Anderson, Molly

    2009-01-01

    Air stripping and distillation are two different gravity-based methods, which may be applied to the purification of wastewater on the lunar base. These gravity-based solutions to water processing are robust physical separation techniques, which may be advantageous to many other techniques for their simplicity in design and operation. The two techniques can be used in conjunction with each other to obtain high purity water. The components and feed compositions for modeling waste water streams are presented in conjunction with the Aspen property system for traditional stage distillation models and air stripping models. While the individual components for each of the waste streams will vary naturally within certain bounds, an analog model for waste water processing is suggested based on typical concentration ranges for these components. Target purity levels for the for recycled water are determined for each individual component based on NASA s required maximum contaminant levels for potable water Distillation processes are modeled separately and in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Optimum parameters such as reflux ratio, feed stage location, and processing rates are determined with respect to the power consumption of the process. Multistage distillation is evaluated for components in wastewater to determine the minimum number of stages necessary for each of 65 components in humidity condensate and urine wastewater mixed streams. Components of the wastewater streams are ranked by Henry s Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates.

  13. Detection limits of the strip test and PCR for genetically modified corn in Brazil.

    PubMed

    Nascimento, V E; Von Pinho, É V R; Von Pinho, R G; do Nascimento, A D

    2012-08-16

    Brazilian legislation establishes a labeling limit for products that contain more than 1% material from genetically modified organisms (GMOs). We assessed the sensitivity of the lateral flow strip test in detection of the GMO corn varieties Bt11 and MON810 and the specificity and sensitivity of PCR techniques for their detection. For the strip test, the GMO seeds were mixed with conventional seeds at levels of 0.2, 0.4 and 0.8% for Bt11, and 0.4, 0.8 and 1.6% for MON810. Three different methodologies were assessed and whole seeds, their endosperm and embryonic axis were used. For the PCR technique, the GMO seeds of each of the two varieties were mixed with conventional seeds at levels of 20, 10, 5, 2, 1, and 0.5%. The seeds were ground and the DNA extracted. For detection of the GMO material, specific primers were used for MON810 and Bt11 and maize zein as an endogenous control. The sensitivity of the strip test varied for both maize varieties and methodologies. The test was positive for Bt11 only at 0.8%, in contrast with the detection limit of 0.4% indicated by the manufacturer. In the multiplex PCR, the primers proved to be specific for the different varieties. These varieties were detected in samples with one GMO seed in 100. Thus, this technique proved to be efficient in detecting contaminations equal to or greater than 1%.

  14. FDTD subcell graphene model beyond the thin-film approximation

    NASA Astrophysics Data System (ADS)

    Valuev, Ilya; Belousov, Sergei; Bogdanova, Maria; Kotov, Oleg; Lozovik, Yurii

    2017-01-01

    A subcell technique for calculation of optical properties of graphene with the finite-difference time-domain (FDTD) method is presented. The technique takes into account the surface conductivity of graphene which allows the correct calculation of its dispersive response for arbitrarily polarized incident waves interacting with the graphene. The developed technique is verified for a planar graphene sheet configuration against the exact analytical solution. Based on the same test case scenario, we also show that the subcell technique demonstrates a superior accuracy and numerical efficiency with respect to the widely used thin-film FDTD approach for modeling graphene. We further apply our technique to the simulations of a graphene metamaterial containing periodically spaced graphene strips (graphene strip-grating) and demonstrate good agreement with the available theoretical results.

  15. A model for prediction of profile and flatness of hot and cold rolled flat products in four-high mills

    NASA Astrophysics Data System (ADS)

    Overhagen, Christian; Mauk, Paul Josef

    2018-05-01

    For flat rolled products, the thickness profile in the transversal direction is one of the most important product properties. For further processing, a defined crown of the product is necessary. In the rolling process, several mechanical and thermal influences interact with each other to form the strip shape at the roll gap exit. In the present analysis, a process model for rolling of strip and sheet is presented. The core feature of the process model is a two-dimensional stress distribution model based on von Karman's differential equation. Sub models for the mechanical influences of work roll flattening as well as work and backup roll deflection and the thermal influence of work roll expansion have been developed or extended. The two-dimensional stress distribution serves as an input parameter for the roll deformation models. For work roll flattening, a three-dimensional model based on the Boussinesq problem is adopted, while the work and backup roll deflection, including contact flattening is calculated by means of finite beam elements. The thermal work roll crown is calculated with help of an axisymmetric numerical solution of the heat equation for the work roll, considering azimuthal averaging for the boundary conditions at the work roll surface. Results are presented for hot rolling of a strip in a seven-stand finishing train of a hot strip mill, showing the calculated evolution of the strip profile. A variation of the strip profile from the first to the 20th rolled strip is shown. This variation is addressed to the progressive increase of work roll temperature during the first 20 strips. It is shown that a CVC® system can lead to improvements in strip profile and therefore flatness.

  16. Biomechanical measurements of stopping and stripping torques during screw insertion in five types of human and artificial humeri.

    PubMed

    Aziz, Mina Sr; Tsuji, Matthew Rs; Nicayenzi, Bruce; Crookshank, Meghan C; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2014-05-01

    During orthopedic surgery, screws are inserted by "subjective feel" in humeri for fracture fixation, that is, stopping torque, while trying to prevent accidental over-tightening that causes screw-bone interface failure, that is, stripping torque. However, no studies exist on stopping torque, stripping torque, or stopping/stripping torque ratio in human or artificial humeri. This study evaluated five types of humeri, namely, human fresh-frozen (n = 19), human embalmed (n = 18), human dried (n = 15), artificial "normal" (n = 13), and artificial "osteoporotic" (n = 13). An orthopedic surgeon used a torque screwdriver to insert 3.5-mm-diameter cortical screws into humeral shafts and 6.5-mm-diameter cancellous screws into humeral heads by "subjective feel" to obtain stopping and stripping torques. The five outcome measures were raw and normalized stopping torque, raw and normalized stripping torque, and stopping/stripping torque ratio. Normalization was done as raw torque/screw-bone interface area. For "gold standard" fresh-frozen humeri, cortical screw tests yielded averages of 1312 N mm (raw stopping torque), 30.4 N/mm (normalized stopping torque), 1721 N mm (raw stripping torque), 39.0 N/mm (normalized stripping torque), and 82% (stopping/stripping torque ratio). Similarly, fresh-frozen humeri gave cancellous screw average results of 307 N mm (raw stopping torque), 0.9 N/mm (normalized stopping torque), 392 N mm (raw stripping torque), 1.2 N/mm (normalized stripping torque), and 79% (stopping/stripping torque ratio). Of the five cortical screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in four cases (embalmed), three cases (dried), four cases (artificial "normal"), and four cases (artificial "osteoporotic"). Of the five cancellous screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in five cases (embalmed), one case (dried), one case (artificial "normal"), and zero cases (artificial "osteoporotic"). Stopping/stripping torque ratios were relatively constant for all groups at 77%-88% (cortical screws) and 79%-92% (cancellous screws). © IMechE 2014.

  17. Data-based hybrid tension estimation and fault diagnosis of cold rolling continuous annealing processes.

    PubMed

    Liu, Qiang; Chai, Tianyou; Wang, Hong; Qin, Si-Zhao Joe

    2011-12-01

    The continuous annealing process line (CAPL) of cold rolling is an important unit to improve the mechanical properties of steel strips in steel making. In continuous annealing processes, strip tension is an important factor, which indicates whether the line operates steadily. Abnormal tension profile distribution along the production line can lead to strip break and roll slippage. Therefore, it is essential to estimate the whole tension profile in order to prevent the occurrence of faults. However, in real annealing processes, only a limited number of strip tension sensors are installed along the machine direction. Since the effects of strip temperature, gas flow, bearing friction, strip inertia, and roll eccentricity can lead to nonlinear tension dynamics, it is difficult to apply the first-principles induced model to estimate the tension profile distribution. In this paper, a novel data-based hybrid tension estimation and fault diagnosis method is proposed to estimate the unmeasured tension between two neighboring rolls. The main model is established by an observer-based method using a limited number of measured tensions, speeds, and currents of each roll, where the tension error compensation model is designed by applying neural networks principal component regression. The corresponding tension fault diagnosis method is designed using the estimated tensions. Finally, the proposed tension estimation and fault diagnosis method was applied to a real CAPL in a steel-making company, demonstrating the effectiveness of the proposed method.

  18. The application of satellite data in monitoring strip mines

    NASA Technical Reports Server (NTRS)

    Sharber, L. A.; Shahrokhi, F.

    1977-01-01

    Strip mines in the New River Drainage Basin of Tennessee were studied through use of Landsat-1 imagery and aircraft photography. A multilevel analysis, involving conventional photo interpretation techniques, densitometric methods, multispectral analysis and statistical testing was applied to the data. The Landsat imagery proved adequate for monitoring large-scale change resulting from active mining and land-reclamation projects. However, the spatial resolution of the satellite imagery rendered it inadequate for assessment of many smaller strip mines, in the region which may be as small as a few hectares.

  19. Grain size control of rhenium strip

    NASA Technical Reports Server (NTRS)

    Schuster, Gary B.

    1991-01-01

    Ensuring the desired grain size in the pure Re strip employed by the SP-100 space nuclear reactor design entails the establishment of an initial grain size in the as-received strip and the avoidance of excessive grain growth during subsequent fabrication. Pure Re tapered tensile specimens have been fabricated and tested in order to quantify the effects of grain-boundary migration. Grain size could be rendered fine and uniform by means of a rolling procedure that uses rather large reductions between short intermediate anneals. The critical strain regime varies inversely with annealing temperature.

  20. Low-resistance strip sensors for beam-loss event protection

    NASA Astrophysics Data System (ADS)

    Ullán, M.; Benítez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; García, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A. A.; Sadrozinski, H. F.-W.

    2014-11-01

    AC-coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the "far" end of the strip from the punch-through structure leading to large voltages. We present here our developments to fabricate low-resistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology.

  1. Phosphorus load to surface water from bank erosion in a Danish lowland river basin.

    PubMed

    Kronvang, Brian; Audet, Joachim; Baattrup-Pedersen, Annette; Jensen, Henning S; Larsen, Søren E

    2012-01-01

    Phosphorus loss from bank erosion was studied in the catchment of River Odense, a lowland Danish river basin, with the aim of testing the hypothesis of whether stream banks act as major diffuse phosphorus (P) sources at catchment scale. Furthermore, the study aimed at analyzing the impact of different factors influencing bank erosion and P loss such as stream order, anthropogenic disturbances, width of uncultivated buffer strips, and the vegetation of buffer strips. A random stratified procedure in geographical information system (GIS) was used to select two replicate stream reaches covering different stream orders, channelized vs. naturally meandering channels, width of uncultivated buffer strips (≤ 2 m and ≥ 10 m), and buffer strips with different vegetation types. Thirty-six 100-m stream reaches with 180 bank plots and a total of 3000 erosion pins were established in autumn 2006, and readings were conducted during a 3-yr period (2006-2009). The results show that neither stream size nor stream disturbance measured as channelization of channel or the width of uncultivated buffer strip had any significant ( < 0.05) influence on bank erosion and P losses during each of the 3 yr studied. In buffer strips with natural trees bank erosion was significantly ( < 0.05) lower than in buffer strips dominated by grass and herbs. Gross and net P input from bank erosion amounted to 13.8 to 16.5 and 2.4 to 6.3 t P, respectively, in the River Odense catchment during the three study years. The net P input from bank erosion equaled 17 to 29% of the annual total P export and 21 to 62% of the annual export of P from diffuse sources from the River Odense catchment. Most of the exported total P was found to be bioavailable (71.7%) based on a P speciation of monthly suspended sediment samples collected at the outlet of the river basin. The results found in this study have a great importance for managers working with P mitigation and modeling at catchment scale. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Cold-Rolled Strip Steel Stress Detection Technology Based on a Magnetoresistance Sensor and the Magnetoelastic Effect

    PubMed Central

    Guan, Ben; Zang, Yong; Han, Xiaohui; Zheng, Kailun

    2018-01-01

    Driven by the demands for contactless stress detection, technologies are being used for shape control when producing cold-rolled strips. This paper presents a novel contactless stress detection technology based on a magnetoresistance sensor and the magnetoelastic effect, enabling the detection of internal stress in manufactured cold-rolled strips. An experimental device was designed and produced. Characteristics of this detection technology were investigated through experiments assisted by theoretical analysis. Theoretically, a linear correlation exists between the internal stress of strip steel and the voltage output of a magneto-resistive sensor. Therefore, for this stress detection system, the sensitivity of the stress detection was adjusted by adjusting the supply voltage of the magnetoresistance sensor, detection distance, and other relevant parameters. The stress detection experimental results showed that this detection system has good repeatability and linearity. The detection error was controlled within 1.5%. Moreover, the intrinsic factors of the detected strip steel, including thickness, carbon percentage, and crystal orientation, also affected the sensitivity of the detection system. The detection technology proposed in this research enables online contactless detection and meets the requirements for cold-rolled steel strips. PMID:29883387

  3. A demonstration of ERTS-1 analog and digital techniques applied to strip mining in Maryland and West Virginia

    NASA Technical Reports Server (NTRS)

    Anderson, A. T.; Schubert, J.

    1974-01-01

    The largest contour strip mining operations in western Maryland and West Virginia are located within the Georges Creek and the Upper Potomac Basins. These two coal basins lie within the Georges Creek (Wellersburg) syncline. The disturbed strip mine areas were delineated with the surrounding geological and vegetation features using ERTS-1 data in both analog (imagery) and digital form. The two digital systems used were: (1) the ERTS-Analysis system, a point-by-point digital analysis of spectral signatures based on known spectral values, and (2) the LARS Automatic Data Processing System. The digital techniques being developed will later be incorporated into a data base for land use planning. These two systems aided in efforts to determine the extent and state of strip mining in this region. Aircraft data, ground verification information, and geological field studies also aided in the application of ERTS-1 imagery to perform an integrated analysis that assessed the adverse effects of strip mining. The results indicated that ERTS can both monitor and map the extent of strip mining to determine immediately the acreage affected and indicate where future reclamation and revegetation may be necessary.

  4. Cold-Rolled Strip Steel Stress Detection Technology Based on a Magnetoresistance Sensor and the Magnetoelastic Effect.

    PubMed

    Guan, Ben; Zang, Yong; Han, Xiaohui; Zheng, Kailun

    2018-05-21

    Driven by the demands for contactless stress detection, technologies are being used for shape control when producing cold-rolled strips. This paper presents a novel contactless stress detection technology based on a magnetoresistance sensor and the magnetoelastic effect, enabling the detection of internal stress in manufactured cold-rolled strips. An experimental device was designed and produced. Characteristics of this detection technology were investigated through experiments assisted by theoretical analysis. Theoretically, a linear correlation exists between the internal stress of strip steel and the voltage output of a magneto-resistive sensor. Therefore, for this stress detection system, the sensitivity of the stress detection was adjusted by adjusting the supply voltage of the magnetoresistance sensor, detection distance, and other relevant parameters. The stress detection experimental results showed that this detection system has good repeatability and linearity. The detection error was controlled within 1.5%. Moreover, the intrinsic factors of the detected strip steel, including thickness, carbon percentage, and crystal orientation, also affected the sensitivity of the detection system. The detection technology proposed in this research enables online contactless detection and meets the requirements for cold-rolled steel strips.

  5. Correction of microplate location effects improves performance of the thrombin generation test

    PubMed Central

    2013-01-01

    Background Microplate-based thrombin generation test (TGT) is widely used as clinical measure of global hemostatic potential and it becomes a useful tool for control of drug potency and quality by drug manufactures. However, the convenience of the microtiter plate technology can be deceiving: microplate assays are prone to location-based variability in different parts of the microtiter plate. Methods In this report, we evaluated the well-to-well consistency of the TGT variant specifically applied to the quantitative detection of the thrombogenic substances in the immune globulin product. We also studied the utility of previously described microplate layout designs in the TGT experiment. Results Location of the sample on the microplate (location effect) contributes to the variability of TGT measurements. Use of manual pipetting techniques and applications of the TGT to the evaluation of procoagulant enzymatic substances are especially sensitive. The effects were not sensitive to temperature or choice of microplate reader. Smallest location effects were observed with automated dispenser-based calibrated thrombogram instrument. Even for an automated instrument, the use of calibration curve resulted in up to 30% bias in thrombogenic potency assignment. Conclusions Use of symmetrical version of the strip-plot layout was demonstrated to help to minimize location artifacts even under the worst-case conditions. Strip-plot layouts are required for quantitative thrombin-generation based bioassays used in the biotechnological field. PMID:23829491

  6. Correction of microplate location effects improves performance of the thrombin generation test.

    PubMed

    Liang, Yideng; Woodle, Samuel A; Shibeko, Alexey M; Lee, Timothy K; Ovanesov, Mikhail V

    2013-07-05

    Microplate-based thrombin generation test (TGT) is widely used as clinical measure of global hemostatic potential and it becomes a useful tool for control of drug potency and quality by drug manufactures. However, the convenience of the microtiter plate technology can be deceiving: microplate assays are prone to location-based variability in different parts of the microtiter plate. In this report, we evaluated the well-to-well consistency of the TGT variant specifically applied to the quantitative detection of the thrombogenic substances in the immune globulin product. We also studied the utility of previously described microplate layout designs in the TGT experiment. Location of the sample on the microplate (location effect) contributes to the variability of TGT measurements. Use of manual pipetting techniques and applications of the TGT to the evaluation of procoagulant enzymatic substances are especially sensitive. The effects were not sensitive to temperature or choice of microplate reader. Smallest location effects were observed with automated dispenser-based calibrated thrombogram instrument. Even for an automated instrument, the use of calibration curve resulted in up to 30% bias in thrombogenic potency assignment. Use of symmetrical version of the strip-plot layout was demonstrated to help to minimize location artifacts even under the worst-case conditions. Strip-plot layouts are required for quantitative thrombin-generation based bioassays used in the biotechnological field.

  7. Two rapid pigmentation tests for identification of Cryptococcus neoformans.

    PubMed Central

    Kaufmann, C S; Merz, W G

    1982-01-01

    Two tests were developed for the rapid identification of Cryptococcus neoformans based on pigment produced by the organism's phenoloxidase activity. Caffeic acid was incorporated into cornmeal agar, a medium used routinely for yeast identification. When tested on this medium, only C. neoformans isolates produced brown pigment. All other yeasts maintained their normal morphology and did not produce the reaction product. A non-medium-based test was developed for same-day identification of C. neoformans isolates. Paper strips saturated with a buffered L-beta-3,4-dihydroxyphenylalanine-ferric citrate solution were inoculated with isolates and incubated at 37 degrees C. Pigment production occurred only with C. neoformans isolates, many within 60 to 90 min. All other yeasts remained negative. PMID:7040452

  8. Integrated Joule switches for the control of current dynamics in parallel superconducting strips

    NASA Astrophysics Data System (ADS)

    Casaburi, A.; Heath, R. M.; Cristiano, R.; Ejrnaes, M.; Zen, N.; Ohkubo, M.; Hadfield, R. H.

    2018-06-01

    Understanding and harnessing the physics of the dynamic current distribution in parallel superconducting strips holds the key to creating next generation sensors for single molecule and single photon detection. Non-uniformity in the current distribution in parallel superconducting strips leads to low detection efficiency and unstable operation, preventing the scale up to large area sensors. Recent studies indicate that non-uniform current distributions occurring in parallel strips can be understood and modeled in the framework of the generalized London model. Here we build on this important physical insight, investigating an innovative design with integrated superconducting-to-resistive Joule switches to break the superconducting loops between the strips and thus control the current dynamics. Employing precision low temperature nano-optical techniques, we map the uniformity of the current distribution before- and after the resistive strip switching event, confirming the effectiveness of our design. These results provide important insights for the development of next generation large area superconducting strip-based sensors.

  9. SU-E-T-24: Development and Implementation of an Automated Algorithm to Determine Radiation Isocenter, Radiation vs. Light Field Coincidence, and Analyze Strip Tests.

    PubMed

    Hyer, D; Mart, C

    2012-06-01

    The aim of this study was to develop a phantom and analysis software that could be used to quickly and accurately determine the location of radiation isocenter using the Electronic Portal Imaging Device (EPID). The phantom could then be used as a static reference point for performing other tests including: radiation vs. light field coincidence, MLC and Jaw strip tests, and Varian Optical Guidance Platform (OGP) calibration. The solution proposed uses a collimator setting of 10×10 cm to acquire EPID images of the new phantom constructed from LEGO® blocks. Images from a number of gantry and collimator angles are analyzed by the software to determine the position of the jaws and center of the phantom in each image. The distance between a chosen jaw and the phantom center is then compared to the same distance measured after a 180 degree collimator rotation to determine if the phantom is centered in the dimension being investigated. The accuracy of the algorithm's measurements were verified by independent measurement to be approximately equal to the detector's pitch. Light versus radiation field as well as MLC and Jaw strip tests are performed using measurements based on the phantom center once located at the radiation isocenter. Reproducibility tests show that the algorithm's results were objectively repeatable. Additionally, the phantom and software are completely independent of linac vendor and this study presents results from two major linac manufacturers. An OGP calibration array was also integrated into the phantom to allow calibration of the OGP while the phantom is positioned at radiation isocenter to reduce setup uncertainty contained in the calibration. This solution offers a quick, objective method to perform isocenter localization as well as laser alignment, OGP calibration, and other tests on a monthly basis. © 2012 American Association of Physicists in Medicine.

  10. Development of an improved PCR-ICT hybrid assay for direct detection of Legionellae and Legionella pneumophila from cooling tower water specimens.

    PubMed

    Horng, Yu-Tze; Soo, Po-Chi; Shen, Bin-Jon; Hung, Yu-Li; Lo, Kai-Yin; Su, Hsun-Pi; Wei, Jun-Rong; Hsieh, Shang-Chen; Hsueh, Po-Ren; Lai, Hsin-Chih

    2006-06-01

    A novelly improved polymerase chian reaction and immunochromatography test (PCR-ICT) hybrid assay comprising traditional multiplex-nested PCR and ICT, (a lateral-flow device) was developed for direct detection of Legionella bacteria from environmental cooling tower samples. The partial 16S rDNA (specific for Legionella spp.) and dnaJ (specific for Legionella pneumophila) genes from Legionella chromosome were first specifically amplified by multiplex-nested PCR, respectively, followed by detection using ICT strip. Reading of results was based on presence or absence of the two test lines on the strips. Presence of test line 1 indicated existence of Legionella spp. specific 16S rDNA and identified Legionella spp. Presence of test line 2 further indicated existence of dnaJ and thus specifically identified L. pneumophila. In contrast, for non-Legionellae bacteria no test line formation was observed. Results of direct detection of Legionella bacteria and L. pneumophila from water tower specimens by this assay showed 100% sensitivity, and 96.6% and 100% specificity, respectively compared with traditional culture, biochemical and serological identification methods. The PCR-ICT hybrid assay does not require sophisticated equipment and was proved to be practically useful in rapid and direct Legionellae detection from environmental water samples.

  11. Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips

    NASA Technical Reports Server (NTRS)

    Doble, Nathan A.; Hansman, R. John

    2002-01-01

    There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.

  12. Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.

    PubMed Central

    Smith, P B; Rhoden, D L; Tomfohrde, K M

    1975-01-01

    The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in a double-blind study with conventional media and procedures as the alternate system. Two newly developed test strips, for 0-nitrophenyl-beta-D-galactopyranoside and ornithine decarboxylase, were found to be highly reliable. PMID:1041590

  13. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis.

    PubMed

    Nibhanipudi, Kumara V

    2015-01-01

    A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) From data configuration Rapid Strep versus LE test don't seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null HYPOTHESIS and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  14. Development of a Sonar Oil Tanker Cargo Measurement System.

    DTIC Science & Technology

    1980-08-01

    used at any one time is dependent upon the capacity of the stripping system. The operation is conducted to strip at least as fast , if not faster, than...operational mode, measure the average value and variance of the thickness of an oil layer on an intermit - tent sampling basis. Laboratory testing

  15. BUBBLE STRIPPING TO DETERMINE HYDROGEN CONCENTRATIONS IN GROUND WATER: A PRACTICAL APPLICATION OF HENRY'S LAW

    EPA Science Inventory

    The Bubble Stripping Method is a chemical testing method that operates on the principle of Henry's Law. It is useful for determining concentrations of hydrogen in well water, and it is capable of detecting concentrations on the order of nanomoles per liter. The method provides ...

  16. Hollow Au-Ag Nanoparticles Labeled Immunochromatography Strip for Highly Sensitive Detection of Clenbuterol

    NASA Astrophysics Data System (ADS)

    Wang, Jingyun; Zhang, Lei; Huang, Youju; Dandapat, Anirban; Dai, Liwei; Zhang, Ganggang; Lu, Xuefei; Zhang, Jiawei; Lai, Weihua; Chen, Tao

    2017-01-01

    The probe materials play a significant role in improving the detection efficiency and sensitivity of lateral-flow immunochromatographic test strip (ICTS). Unlike conventional ICTS assay usually uses single-component, solid gold nanoparticles as labeled probes, in our present study, a bimetallic, hollow Au-Ag nanoparticles (NPs) labeled ICTS was successfully developed for the detection of clenbuterol (CLE). The hollow Au-Ag NPs with different Au/Ag mole ratio and tunable size were synthesized by varying the volume ratio of [HAuCl4]:[Ag NPs] via the galvanic replacement reaction. The surface of hollow Ag-Au NPs was functionalized with 11-mercaptoundecanoic acid (MUA) for further covalently bonded with anti-CLE monoclonal antibody. Overall size of the Au-Ag NPs, size of the holes within individual NPs and also Au/Ag mole ratio have been systematically optimized to amplify both the visual inspection signals and the quantitative data. The sensitivity of optimized hollow Au-Ag NPs probes has been achieved even as low as 2 ppb in a short time (within 15 min), which is superior over the detection performance of conventional test strip using Au NPs. The optimized hollow Au-Ag NPs labeled test strip can be used as an ideal candidate for the rapid screening of CLE in food samples.

  17. You’re a good structure, Charlie Brown: The distribution of narrative categories in comic strips

    PubMed Central

    Cohn, Neil

    2014-01-01

    Cohn’s (2013) theory of “Visual Narrative Grammar” argues that sequential images take on categorical roles in a narrative structure, which organizes them into hierarchic constituents analogous to the organization of syntactic categories in sentences. This theory proposes that narrative categories, like syntactic categories, can be identified through diagnostic tests that reveal tendencies for their distribution throughout a sequence. This paper describes four experiments testing these diagnostics to provide support for the validity of these narrative categories. In Experiment 1, participants reconstructed unordered panels of a comic strip into an order that makes sense. Experiment 2 measured viewing times to panels in sequences where the order of panels was reversed. In Experiment 3 participants again reconstructed strips, but also deleted a panel from the sequence. Finally, in Experiment 4 participants identified where a panel had been deleted from a comic strip, and rated that strip’s coherence. Overall, categories had consistent distributional tendencies within experiments and complementary tendencies across experiments. These results point toward an interaction between categorical roles and a global narrative structure. PMID:24646175

  18. First Comprehensive Evaluation of the M.I.C. Evaluator Device Compared to Etest and CLSI Broth Microdilution for MIC Testing of Aerobic Gram-Positive and Gram-Negative Bacterial Species

    PubMed Central

    Turnbull, L.; Brosnikoff, C.; Cloke, J.

    2012-01-01

    The M.I.C. Evaluator strip (Thermo Fisher Scientific, Basingstoke, United Kingdom) uses a methodology similar to that of Etest. In this first assessment of the M.I.C. Evaluator device, 409 strains of aerobic Gram-positive bacteria (staphylococci, streptococci, and enterococci) and 325 strains of Enterobacteriaceae, Pseudomonas species, and Acinetobacter species were tested by M.I.C. Evaluator strip, Etest, and broth microdilution as a reference standard. The Gram-positive bacteria included staphylococci (methicillin-resistant Staphylococcus aureus, methicillin-susceptible S. aureus, and coagulase-negative staphylococci), Streptococcus pneumoniae, beta-hemolytic streptococci and viridians group strains, vancomycin-resistant enterococci, and other enterococci. The Gram-negative bacteria included 250 strains of 60 Enterobacteriaceae species plus 50 Pseudomonas and 25 Acinetobacter species. A total of 14 antimicrobial agents (depending on the species) were included. The same methodology and reading format were used for M.I.C. Evaluator strips and Etest. Broth microdilution methodology was performed according to CLSI document M07-A8. For the clinical strains, >95% of results were plus or minus one doubling dilution for all species. There were fewer than 5% minor errors, fewer than 3% major errors, and fewer than 1% very major errors. M.I.C. Evaluator strips and Etest often reported higher MICs than the reference broth microdilution method. The M.I.C. Evaluator strips provided results comparable to those of the predicate Etest device and are of value for the accurate testing of MICs for these important pathogens. PMID:22238441

  19. Deposits from Creams Containing 20% (w/w) Urea and Suppression of Crystallization (Part 2): Novel Analytical Methods of Urea Accumulated in the Stratum Corneum by Tape stripping and Colorimetry.

    PubMed

    Goto, Norio; Morita, Yutaka; Terada, Katsuhide

    2016-01-01

    The transfer of urea from a urea formulation to the stratum corneum varies with the formulation base and form, and impacts the formulation's therapeutic effect. Consequently, determining the amount of urea transferred is essential for developing efficient formulations. This study assessed a simple method for measuring the amount of urea accumulated in the stratum corneum. Conventional methods rely on labeling urea used in the formulation with radiocarbon ((14)C) or other radioactive isotopes (RIs), retrieving the transferred urea from the stratum corneum by tape stripping, then quantitating the urea. The handling and use of RIs, however, is subject to legal regulation and can only be performed in sanctioned facilities, so methods employing RIs are neither simple nor convenient. We therefore developed a non-radiolabel method "tape stripping-colorimetry (T-C)" that combines tape stripping with colorimetry (urease-glutamate dehydrogenase (GLDH)) for the quantitative measurement of urea. Urea in the stratum corneum is collected by tape stripping and measured using urease-GLDH, which is commonly used to measure urea nitrogen in blood tests. The results indicate that accurate urea measurement by the T-C method requires the application of 1400 mg (on hairless rats) of a 20% urea solution on a 50 cm(2) (5×10 cm) area. Further, we determined the amount of urea accumulated in the stratum corneum using formulations with different urea concentrations, and the time course of urea accumulation from formulations differing in the rate of urea crystallization. We demonstrate that the T-C method is simple and convenient, with no need for (14)C or other RIs.

  20. Rapid detection of methicillin-resistant Staphylococcus aureus in pork using a nucleic acid-based lateral flow immunoassay.

    PubMed

    Zhang, Hongwei; Ma, Luyao; Ma, Lina; Hua, Marti Z; Wang, Shuo; Lu, Xiaonan

    2017-02-21

    Methicillin-resistant Staphylococcus aureus (MRSA) is considered as one of the leading causes of food poisonings worldwide. Due to the high prevalence and extensive challenges in clinical treatment, a rapid and accurate detection method is required to differentiate MRSA from other S. aureus isolated from foods. Since the methicillin resistance of S. aureus is due to the acquisition of the mecA gene from staphylococcal chromosome cassette, the presence of the mecA gene is interpreted as a marker for the identification of MRSA. In this study, a low-cost lateral flow immunoassay (LFI) strip was used to detect the mecA amplicons subsequent to polymerase chain reaction (PCR). The specificity of this PCR-LFI assay was tested between MRSA and methicillin-susceptive S. aureus. Both the test line and control line were shown up on the LFI strip for MRSA, whereas only the control line developed for methicillin-susceptive S. aureus. The detection limit of PCR-LFI assay was 20fg for genomic DNA (100 times more sensitive than gel electrophoresis) and 2×10 0 CFU per 100g of pork products after enrichment at 37°C for 48h. The total detection time of using LFI was 3min, which was faster than the conventional electrophoresis (~45min). With the performance of PCR-LFI, 7 out of 42 S. aureus isolates were identified to be MRSA from imported pork products, which was consistent to the standardized minimum inhibitory concentration assay. This mecA-based PCR-LFI strip can be used for rapid and accurate detection of MRSA isolated from commercial pork products. Copyright © 2016. Published by Elsevier B.V.

  1. Mobile large area confocal scanner for imaging tumor margins: initial testing in the pathology department

    NASA Astrophysics Data System (ADS)

    Abeytunge, Sanjee; Li, Yongbiao; Larson, Bjorg; Peterson, Gary; Toledo-Crow, Ricardo; Rajadhyaksha, Milind

    2013-03-01

    Surgical oncology is guided by examining pathology that is prepared during or after surgery. The preparation time for Mohs surgery in skin is 20-45 minutes, for head-and-neck and breast cancer surgery is hours to days. Often this results in incomplete tumor removal such that positive margins remain. However, high resolution images of excised tissue taken within few minutes can provide a way to assess the margins for residual tumor. Current high resolution imaging methods such as confocal microscopy are limited to small fields of view and require assembling a mosaic of images in two dimensions (2D) to cover a large area, which requires long acquisition times and produces artifacts. To overcome this limitation we developed a confocal microscope that scans strips of images with high aspect ratios and stitches the acquired strip-images in one dimension (1D). Our "Strip Scanner" can image a 10 x 10 mm2 area of excised tissue with sub-cellular detail in about one minute. The strip scanner was tested on 17 Mohs excisions and the mosaics were read by a Mohs surgeon blinded to the pathology. After this initial trial, we built a mobile strip scanner that can be moved into different surgical settings. A tissue fixture capable of scanning up to 6 x 6 cm2 of tissue was also built. Freshly excised breast and head-and-neck tissues were imaged in the pathology lab. The strip-images were registered and displayed simultaneously with image acquisition resulting in large, high-resolution confocal mosaics of fresh surgical tissue in a clinical setting.

  2. The effects of whole-vault cranioplasty versus strip craniectomy on long-term neuropsychological outcomes in sagittal craniosynostosis.

    PubMed

    Hashim, Peter W; Patel, Anup; Yang, Jenny F; Travieso, Roberto; Terner, Jordan; Losee, Joseph E; Pollack, Ian; Jane, John; Jane, John; Kanev, Paul; Mayes, Linda; Duncan, Charles; Bridgett, David J; Persing, John A

    2014-09-01

    The optimal type of surgical management for isolated sagittal synostosis remains a source of significant debate. There is a paucity of data regarding possible differences in long-term neuropsychological outcomes following treatment with whole-vault cranioplasty or endoscopic strip craniectomy. This study provides the first comparative analysis examining the effects of the two techniques related to long-term intellectual functioning. A total of 70 patients were enrolled in this multicenter study, 29 of whom had previously undergone endoscopic strip craniectomy and 41 of whom had previously undergone whole-vault cranioplasty. All patients completed a battery of neurodevelopmental tests (Beery-Buktenica Developmental Test of Visual-Motor Integration, Wechsler Abbreviated Scale of Intelligence, and Wechsler Fundamentals) to evaluate various domains of neuropsychological function. In a group comparison of those treated before 6 months of age, whole-vault patients obtained higher scores relative to endoscopic strip craniectomy patients on visuomotor integration, full-scale intelligence quotient, verbal intelligence quotient, word reading, and reading comprehension (p < 0.05 for all). When compared against strip craniectomy performed before 3 months of age, the whole-vault group still showed significantly higher scores in verbal intelligence quotient, reading comprehension, and word reading (p < 0.05 for all). The type of surgical intervention for isolated sagittal synostosis impacts long-term neuropsychological outcomes. Patients undergoing early whole-vault cranioplasty attained higher intelligence quotient and achievement scores relative to those undergoing strip craniectomy. Surgical management with whole-vault cranioplasty performed before 6 months of age provides the most favorable long-term intellectual outcomes in patients with isolated sagittal synostosis. Therapeutic, II.

  3. Airfoil seal system for gas turbine engine

    DOEpatents

    None, None

    2013-06-25

    A turbine airfoil seal system of a turbine engine having a seal base with a plurality of seal strips extending therefrom for sealing gaps between rotational airfoils and adjacent stationary components. The seal strips may overlap each other and may be generally aligned with each other. The seal strips may flex during operation to further reduce the gap between the rotational airfoils and adjacent stationary components.

  4. Analysis/design of strip reinforced random composites (strip hybrids)

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Sinclair, J. H.

    1978-01-01

    Advanced analysis methods and composite mechanics were applied to a strip-reinforced random composite square panel with fixed ends to illustrate the use of these methods for the a priori assessment of the composite panel when subjected to complex loading conditions. The panel was assumed to be of E-glass random composite. The strips were assumed to be of three advanced unidirectional composites to cover a range of low, intermediate, and high modulus stiffness. The panels were assumed to be subjected to complex loadings to assess their adequacy as load-carrying members in auto body, aircraft engine nacelle and windmill blade applications. The results show that strip hybrid panels can be several times more structurally efficient than the random composite base materials. Some of the results are presented in graphical form and procedures are described for use of these graphs as guides for preliminary design of strip hybrids.

  5. Non-invasive characterization and quality assurance of silicon micro-strip detectors using pulsed infrared laser

    NASA Astrophysics Data System (ADS)

    Ghosh, P.

    2016-01-01

    The Compressed Baryonic Matter (CBM) experiment at FAIR is composed of 8 tracking stations consisting of roughly 1300 double sided silicon micro-strip detectors of 3 different dimensions. For the quality assurance of prototype micro-strip detectors a non-invasive detector charaterization is developed. The test system is using a pulsed infrared laser for charge injection and characterization, called Laser Test System (LTS). The system is aimed to develop a set of characterization procedures which are non-invasive (non-destructive) in nature and could be used for quality assurances of several silicon micro-strip detectors in an efficient, reliable and reproducible way. The procedures developed (as reported here) uses the LTS to scan sensors with a pulsed infra-red laser driven by step motor to determine the charge sharing in-between strips and to measure qualitative uniformity of the sensor response over the whole active area. The prototype detector modules which are tested with the LTS so far have 1024 strips with a pitch of 58 μm on each side. They are read-out using a self-triggering prototype read-out electronic ASIC called n-XYTER. The LTS is designed to measure sensor response in an automatized procedure at several thousand positions across the sensor with focused infra-red laser light (spot size ≈ 12 μm, wavelength = 1060 nm). The pulse with a duration of ≈ 10 ns and power ≈ 5 mW of the laser pulse is selected such, that the absorption of the laser light in the 300 μm thick silicon sensor produces ≈ 24000 electrons, which is similar to the charge created by minimum ionizing particles (MIP) in these sensors. The laser scans different prototype sensors and various non-invasive techniques to determine characteristics of the detector modules for the quality assurance is reported.

  6. Rapid Prototyping of a High Sensitivity Graphene Based Glucose Sensor Strip.

    PubMed

    Tehrani, Farshad; Reiner, Lisa; Bavarian, Behzad

    2015-01-01

    A rapid prototyping of an inexpensive, disposable graphene and copper nanocomposite sensor strip using polymeric flexible substrate for highly sensitive and selective nonenzymatic glucose detection has been developed and tested for direct oxidization of glucose. The CuNPs were electrochemically deposited on to the graphene sheets to improve electron transfer rates and to enhance electrocatalytic activity toward glucose. The graphene based electrode with CuNPs demonstrated a high degree of sensitivity (1101.3 ± 56 μA/mM.cm2), excellent selectivity (without an interference with Ascorbic Acid, Uric Acid, Dopamine, and Acetaminophen), good stability with a linear response to glucose ranging from 0.1 mM to 0.6 mM concentration, and detection limits of 0.025 mM to 0.9 mM. Characterization of the electrodes was performed by scanning electron microscopy (FESEM and SEM). The electrochemical properties of the modified graphene electrodes were inspected by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and amperometry.

  7. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    PubMed Central

    Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai

    2013-01-01

    In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water. PMID:23539028

  8. Rapid Prototyping of a High Sensitivity Graphene Based Glucose Sensor Strip

    PubMed Central

    Tehrani, Farshad; Reiner, Lisa; Bavarian, Behzad

    2015-01-01

    A rapid prototyping of an inexpensive, disposable graphene and copper nanocomposite sensor strip using polymeric flexible substrate for highly sensitive and selective nonenzymatic glucose detection has been developed and tested for direct oxidization of glucose. The CuNPs were electrochemically deposited on to the graphene sheets to improve electron transfer rates and to enhance electrocatalytic activity toward glucose. The graphene based electrode with CuNPs demonstrated a high degree of sensitivity (1101.3±56 μA/mM.cm2), excellent selectivity (without an interference with Ascorbic Acid, Uric Acid, Dopamine, and Acetaminophen), good stability with a linear response to glucose ranging from 0.1 mM to 0.6 mM concentration, and detection limits of 0.025 mM to 0.9 mM. Characterization of the electrodes was performed by scanning electron microscopy (FESEM and SEM). The electrochemical properties of the modified graphene electrodes were inspected by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and amperometry. PMID:26678700

  9. Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk

    NASA Astrophysics Data System (ADS)

    Shi, Qiaoqiao; Huang, Jie; Sun, Yaning; Yin, Mengqi; Hu, Mei; Hu, Xiaofei; Zhang, Zhijun; Zhang, Gaiping

    2018-05-01

    An ultrasensitive method for the detection of antibiotics in milk is developed based on inexpensive, simple, rapid and portable lateral flow immunoassay (LFI) strip, in combination with high sensitivity surface-enhanced Raman spectroscopy (SERS). In our strategy, an immunoprobe was prepared from colloidal gold (AuNPs) conjugated with both a monoclonal antibody against neomycin (NEO-mAb) and a Raman probe molecule 4-aminothiophenol (PATP). The competitive interaction with immunoprobe between free NEO and the coated antigen (NEO-OVA) resulted in the change of the amount of the immobilized immunoprobe on the paper substrate. The LFI procedure was completed within 15 min. The Raman intensity of PATP on the test line of the LFI strip was measured for the quantitative determination of NEO. The IC50 and the limit of detection (LOD) of this assay are 0.04 ng/mL and 0.216 pg/mL of NEO, respectively. There is no cross-reactivity (CR) of the assay with other compounds, showing high specificity of the assay. The recoveries for milk samples with added NEO are in the range of 89.7%-105.6% with the relative standard deviations (RSD) of 2.4%-5.3% (n = 3). The result reveals that this method possesses high specificity, sensitivity, reproducibility and stability, and can be used to detect a variety of antibiotic residues in milk samples.

  10. A Front-End Electronics Prototype Based on Gigabit Ethernet for the ATLAS Small-Strip Thin Gap Chamber

    NASA Astrophysics Data System (ADS)

    Hu, Kun; Lu, Houbing; Wang, Xu; Li, Feng; Wang, Xinxin; Geng, Tianru; Yang, Hang; Liu, Shengquan; Han, Liang; Jin, Ge

    2017-06-01

    A front-end electronics prototype for the ATLAS small-strip Thin Gap Chamber (sTGC) based on gigabit Ethernet has been developed. The prototype is designed to read out signals of pads, wires, and strips of the sTGC detector. The prototype includes two VMM2 chips developed to read out the signals of the sTGC, a Xilinx Kintex-7 field-programmable gate array (FPGA) used for the VMM2 configuration and the events storage, and a gigabit Ethernet transceiver PHY chip for interfacing with a computer. The VMM2 chip is designed for the readout of the Micromegas detector and sTGC detector, which is composed of 64 linear front-end channels. Each channel integrates a charge-sensitive amplifier, a shaper, several analog-to-digital converters, and other digital functions. For a bunch-crossing interval of 25 ns, events are continuously read out by the FPGA and forwarded to the computer. The interface between the computer and the prototype has been measured to reach an error-free rate of 900 Mb/s, therefore making a very effective use of the available bandwidth. Additionally, the computer can control several prototypes of this kind simultaneously via the Ethernet interface. At present, the prototype will be used for the sTGC performance test. The features of the prototype are described in detail.

  11. Microbial Characterization of Solid-Wastes Treated with Heat Melt Compaction Technology

    NASA Technical Reports Server (NTRS)

    Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.

    2011-01-01

    The research purpose of the project was to determine the fate of microorganisms in space-generated solid wastes after processing by a Heat Melt Compactor (HMC), which is a candidate solid waste treatment technology. Five HMC product disks were generated at Ames Research Center (ARC), Waste Management Systems element. The feed for two was simulated space-generated trash and feed for three was Volume F compartment wet waste returned on STS 130. Conventional microbiological methods were used to detect and enumerate microorganisms in HMC disks and in surface swab samples of HMC hardware before and after operation. Also, biological indicator test strips were added to the STS trash prior to compaction to test if HMC processing conditions, 150 C for approx 3 hr and dehydration, were sufficient to eliminate the test bacteria on the strips. During sample acquisition at KSC, the HMC disk surfaces were sanitized with 70% alcohol to prevent contamination of disk interiors. Results from microbiological assays indicated that numbers of microbes were greatly reduced but not eliminated by the 70% alcohol. Ten 1.25 cm diameter cores were aseptically cut from each disk to sample the disk interior. The core material was run through the microbial characterization analyses after dispersal in sterile diluent. Low counts of viable bacteria (5 to 50 per core) were found but total direct counts were 6 to 8 orders of magnitude greater. These results indicate that the HMC operating conditions might not be sufficient for complete waste sterilization, but the vast majority of microbes present in the wastes were dead or non-cultivable after HMC treatment. The results obtained from analyses of the commercial spore test strips that had been added fo the wastes prior to HMC operation further indicated that the HMC was sterilizing the wastes. Nearly all strips were recovered from the HMC disks and all of these were negative for spore growth when run through the manufacturer's protocol. The 10(exp 6) or so spores impregnated into the strips were no longer viable. Control test strips, i.e., not exposed to the HMC conditions, were all strongly positive. All isolates from the cultivable counts were identified, leading to one concern: several were identified as Staphylococcus aureus, a human pathogen. The project reported here provides microbial characterization support to the Waste Management Systems element of the Life Support and Habitation Systems program.

  12. Water droplet impingement on airfoils and aircraft engine inlets for icing analysis

    NASA Technical Reports Server (NTRS)

    Papadakis, Michael; Elangovan, R.; Freund, George A., Jr.; Breer, Marlin D.

    1991-01-01

    This paper includes the results of a significant research program for verification of computer trajectory codes used in aircraft icing analysis. Experimental water droplet impingement data have been obtained in the NASA Lewis Research Center Icing Research Tunnel for a wide range of aircraft geometries and test conditions. The body whose impingement characteristics are required is covered at strategic locations by thin strips of moisture absorbing (blotter) paper and then exposed to an airstream containing a dyed-water spray cloud. Water droplet impingement data are extracted from the dyed blotter strips by measuring the optical reflectance of the dye deposit on the strips with an automated reflectometer. Impingement characteristics for all test geometries have also been calculated using two recently developed trajectory computer codes. Good agreement is obtained with experimental data. The experimental and analytical data show that maximum impingement efficiency and impingement limits increase with mean volumetric diameter for all geometries tested. For all inlet geometries tested, as the inlet mass flow is reduced, the maximum impingement efficiency is reduced and the location of the maximum impingement shifts toward the inlet inner cowl.

  13. The Effect of Spray Strips on the Take-off Performance of a Model of a Flying-Boat Hull

    NASA Technical Reports Server (NTRS)

    Truscott, Starr

    1935-01-01

    The effect on the take-off performance of a model of the hull of a typical flying boat, Navy PH-1, of fitting spray strips of four different widths, each at three different angles, was determined by model tests in the NACA Tank. Spray strips of widths up to 3 percent of the beam improve the general performance at speeds near the hump and reduce the spray thrown. A downward angle of 30 degrees to 45 degrees in the neighborhood of the step seems most favorable for the reduction of the spray. The spray strips have a large effect in reducing the trimming moments at speeds near the hump speed, but have little effect on them at high speeds.

  14. Digital X-ray portable scanner based on monolithic semi-insulating GaAs detectors: General description and first “quantum” images

    NASA Astrophysics Data System (ADS)

    Dubecký, F.; Perd'ochová, A.; Ščepko, P.; Zat'ko, B.; Sekerka, V.; Nečas, V.; Sekáčová, M.; Hudec, M.; Boháček, P.; Huran, J.

    2005-07-01

    The present work describes a portable digital X-ray scanner based on bulk undoped semi-insulating (SI) GaAs monolithic strip line detectors. The scanner operates in "quantum" imaging mode ("single photon counting"), with potential improvement of the dynamic range in contrast of the observed X-ray images. The "heart" of the scanner (detection unit) is based on SI GaAs strip line detectors. The measured detection efficiency of the SI GaAs detector reached a value of over 60 % (compared to the theoretical one of ˜75 %) for the detection of 60 keV photons at a reverse bias of 200 V. The read-out electronics consists of 20 modules fabricated using a progressive SMD technology with automatic assembly of electronic devices. Signals from counters included in the digital parts of the modules are collected in a PC via a USB port and evaluated by custom developed software allowing X-ray image reconstruction. The collected data were used for the creation of the first X-ray "quantum" images of various test objects using the imaging software developed.

  15. Performance Evaluation of Hap-Free Paint Strippers vs. Methylene-Chloride-Based Strippers for Removing Army Chemical Agent Resistant Coatings (CARC)

    DTIC Science & Technology

    2006-06-01

    Preparation..........................................................................................................3 2.2 Alternatives Selection ...water-borne panels were green. 2.2 Alternatives Selection The Gap Assessment Report generated by CTC/NDCEE identified many HAP-free alternatives to...strip times (as reported by the vendor) of many of the products. ARL used this information to select the alternatives to be included in its test

  16. The use of the Micral-Test strip to identify the presence of microalbuminuria in people with insulin dependent diabetes mellitus (IDDM) participating in the EUCLID study.

    PubMed

    Webb, D J; Newman, D J; Chaturvedi, N; Fuller, J H

    1996-03-01

    In IDDM, microalbuminuria (urinary albumin excretion rate (AER) of 20-200 micrograms/min) is a predictor of persistent proteinuria and diabetic nephropathy. Early intervention may prevent or reduce the rate of progression of renal complications. The Micral-Test strip can be used to establish a semi-quantitative estimate of AER. We assessed the field performance of the Micral-Test strip in detecting microalbuminuria in the EUCLID study, an European wide, 18 centre study of 530 IDDM participants, aged 20 to 59 years. People with macroalbuminuria were excluded. On entry, all participants had albumin concentrations from two overnight urine collections measured by a central laboratory, and the corresponding Micral-Test performed on the two collections locally. a cut off of > or = mg/l albumin from the first Micral-Test, to detect a centrally measured albumin concentration > or = 20 mg/l, yielded 29 (5.8%) false negative results and 58 (11.6%) false positive results (sensitivity 70%, specificity 87%). The mean AER, from two collections, was compared with the corresponding 'pooled' Micral-Test results (mean of the two readings). Receiver Operating Characteristic (ROC) curves were used to assess if there was a suitable 'pooled' Micral-Test result for screening microalbuminuria. A 'pooled' Micral-Test result (> or = 15 mg/l) was used to detect mean AER > or = 20 micrograms/min (sensitivity 78%, specificity 77%). This 'pooled cut-off' had already been used for screening on to the study and led to an over-estimate (154 vs. 77) of the true number of microalbuminuric participants on the study. In conclusion, our findings suggest that the Micral-Test strip is not an effective screening tool for microalbuminuria, using the 'pooled' result from two measurements did not improve the sensitivity of the test.

  17. PRELIMINARY EVALUATION OF DWPF IMPACTS OF BORIC ACID USE IN CESIUM STRIP FOR SWPF AND MCU

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, M.

    2010-09-28

    A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the current dilute nitric acid strip solution with boric acid. To support this effort, the impact of using 0.01M, 0.1M, 0.25M and 0.5M boric acid in place of 0.001M nitric acid was evaluated for impacts on the DWPF facility. The evaluation only covered the impacts of boric acid in the strip effluent and does not address the other changes in solvents (i.e., the new extractant, called MaxCalix,more » or the new suppressor, guanidine). Boric acid additions may lead to increased hydrogen generation during the SRAT and SME cycles as well as change the rheological properties of the feed. The boron in the strip effluent will impact glass composition and could require each SME batch to be trimmed with boric acid to account for any changes in the boron from strip effluent additions. Addition of boron with the strip effluent will require changes in the frit composition and could lead to changes in melt behavior. The severity of the impacts from the boric acid additions is dependent on the amount of boric acid added by the strip effluent. The use of 0.1M or higher concentrations of boric acid in the strip effluent was found to significantly impact DWPF operations while the impact of 0.01M boric acid is expected to be relatively minor. Experimental testing is required to resolve the issues identified during the preliminary evaluation. The issues to be addressed by the testing are: (1) Impact on SRAT acid addition and hydrogen generation; (2) Impact on melter feed rheology; (3) Impact on glass composition control; (4) Impact on frit production; and (5) Impact on melter offgas. A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the current dilute nitric acid strip solution with boric acid. To support this effort, the impact of using 0.01M, 0.1M, 0.25M and 0.5M boric acid in place of 0.001M nitric acid was evaluated for impacts on the DWPF facility. The evaluation only covered the impacts of boric acid in the strip effluent and does not address the other changes in solvents (i.e., the new extractant, called MaxCalix, or the new suppressor, guanidine). Experimental testing with the improved solvent is required to determine the impact of any changes in the entrained solvent on DWPF processing.« less

  18. Control strip study : interim report.

    DOT National Transportation Integrated Search

    1972-01-01

    This report is concerned with the application of the "control strip" technique using nuclear devices for compaction control of certain base courses and asphaltic concrete surface course. The technique, as evaluated here, consisted of applying increas...

  19. Development of a serotype colloidal gold strip using monoclonal antibody for rapid detection type Asia1 foot-and-mouth disease

    PubMed Central

    2011-01-01

    Background In this study, we developed a rapid, one step colloid gold strip (CGS) capable of specifically detecting type Asia1 foot-and-mouth disease virus (FMDV). We have produced two monoclonal antibodies (mAb) to type Asia1 FMD (named 1B8 and 5E2). On the test strip, the purified 1B8 labelled with the colloidal gold was used as the detector, and the purified 5E2 and goat anti-mouse antibodies were wrapped onto nitrocellulose (NC) membranes as the test and the control line, respectively. The rapid colloidal gold stereotype diagnostic strip was housed in a plastic case. Results In specificity and sensitivity assay, there was no cross-reaction of the antigen with the other type of FMD and SVDV. The detection sensitivity was found to be as high as 10-5 dilution of Asia1/JSL/05 (1 × 107.2TCID50/50 μL). There was excellent agreement between the results obtained by CGS and reverse indirect hemagglutination assay (RIHA), and the agreement can reach to 98.75%. Conclusion We developed colloidal gold strips that have good qualities and does not require specialized equipment or technicians. This method provided a feasible, convenient, rapid, and effective for detecting type Asia1 FMDV in the fields. PMID:21880157

  20. Development of a serotype colloidal gold strip using monoclonal antibody for rapid detection type Asia1 foot-and-mouth disease.

    PubMed

    Lin, Tong; Shao, Jun-jun; Du, Jun-zheng; Cong, Guo-zheng; Gao, Shan-dian; Chang, Huiyun

    2011-09-01

    In this study, we developed a rapid, one step colloid gold strip (CGS) capable of specifically detecting type Asia1 foot-and-mouth disease virus (FMDV). We have produced two monoclonal antibodies (mAb) to type Asia1 FMD (named 1B8 and 5E2). On the test strip, the purified 1B8 labelled with the colloidal gold was used as the detector, and the purified 5E2 and goat anti-mouse antibodies were wrapped onto nitrocellulose (NC) membranes as the test and the control line, respectively. The rapid colloidal gold stereotype diagnostic strip was housed in a plastic case. In specificity and sensitivity assay, there was no cross-reaction of the antigen with the other type of FMD and SVDV. The detection sensitivity was found to be as high as 10(-5) dilution of Asia1/JSL/05 (1 × 10(7.2)TCID(50)/50 μL). There was excellent agreement between the results obtained by CGS and reverse indirect hemagglutination assay (RIHA), and the agreement can reach to 98.75%. We developed colloidal gold strips that have good qualities and does not require specialized equipment or technicians. This method provided a feasible, convenient, rapid, and effective for detecting type Asia1 FMDV in the fields.

  1. Evaluation of immunochromatographic test (ICT) strips for the serological detection of Babesia bovis and Babesia bigemina infection in cattle from Western Java, Indonesia.

    PubMed

    Guswanto, Azirwan; Allamanda, Puttik; Mariamah, Euis Siti; Munkjargal, Tserendorf; Tuvshintulga, Bumduuren; Takemae, Hitoshi; Sivakumar, Thillaiampalam; AbouLaila, Mahmoud; Terkawi, Mohamad Alaa; Ichikawa-Seki, Madoka; Nishikawa, Yoshifumi; Yokoyama, Naoaki; Igarashi, Ikuo

    2017-05-30

    Three types of immunochromatographic test (ICT) strips were prepared for the detection of an antibody response against spherical body protein 4 (SBP-4) of Babesia bovis (bovICT), C-terminal-truncated rhoptry-associated protein 1 (rRAP1/CT17) of B. bigemina (bigICT), and the combination of both proteins (dual-ICT). The evaluation of their performance was conducted using a confirmed positive and negative serum panel for B. bovis and B. bigemina. Together with ELISA, the ICT strips were applied to determine the seroprevalence of bovine babesiosis in Western Java, Indonesia. Among 991 serum samples, 28.4%, 25.3%, and 24.5% of cattle were detected to be seropositive to B. bovis infection using ELISA, bovICT, and dual-ICT, respectively. B. bigemina seropositive was detected in 27.1%, 24.2%, and 22.8% of samples using ELISA, bigICT, and dual-ICT, respectively. The comparison of ICT strips and ELISA results using field serum samples showed good agreement with Kappa values >0.7 between all methods The application of ICT strips is preferable in the field situations where rapid diagnosis is required. Furthermore, the data showed the current seroprevalence of bovine babesiosis in Western Java, Indonesia, and efficient control strategies are needed to reduce economic losses due to the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparison of the relaxation effect in vitro of nitroglycerin vs. fenoterol on human myometrial strips.

    PubMed

    David, M; Hamann, C; Chen, F C; Bruch, L; Lichtenegger, W

    2000-01-01

    Substance dose-related comparison of relaxation effect of nitroglycerin (GTN) and the beta 2-mimetic substance fenoterol in human myometrial tissue. Test criterion is the isometric force development of isolated human myometrial strips. These muscle strips were removed from the lower uterine segment at cesarean section. Fenoterol in concentrations of 3 x 10(-8)-10(-5) mol/l or GTN in concentrations of 1.7 x 10(-8)-5.8 x 10(-4) mol/l were applied to the 2 x 2 x 10-mm strips, which were fixed and maintained in tissue baths. The curves were plotted on line. The integral or the "area under the curve" (AUC) served as the parameter for muscle strip activity. A total of 100 strips from 20 patients were used. GTN demonstrated a significant relaxation effect in the in vitro model on human myometrial strips from pregnant women already treated with oxytocin. The effect was able to be enhanced to a point where oxytocin-induced contractions were completely absent. A relatively clear connection was demonstrated between dose and effect whereby increased muscle relaxation resulted at increased concentrations. Compared to GTN application, muscle strip relaxation was less pronounced under fenoterol; a complete inhibition of myometrial activity was not achieved under fenoterol. With respect to relaxation of the myometrial tissue samples the NO donor GTN is at least as potent as the standard tocolytic agent fenoterol in the in vitro model.

  3. [Comparative experiments of stripping sheep maxillary sinus mucosal with new-type stripper and umbrella detacher].

    PubMed

    Jiadong, Fan; Yanfeng, Li; Le, Liu; Yishi, Han; Pin, Hu; Yue, Zhang; Wenya, Bao

    2016-10-01

    To compare the stripping length obtained through the model of 0.012 and 0.014 of the nickel-titanium dual-stage maxillary sinus mucosa stripper, and the umbrella detacher. Twenty-four goats (1.5-2 years old) were chosen, randomly divided into A, B, C groups, each group of eight. Group A was 0.012 model group, group B was 0.014 model group, group C was umbrella detacher group. Animal model was established, and maxillary sinus mucosa was stripped to the left and right sides of the bottom of the sinus in three groups. The data was measured when stripping to the limit or being perforated. The average length of group A was 12.41 mm±4.35 mm, two cases perforated. The average length of group B was 23.38 mm±4.84 mm, one case perforated. The average length of group C was 2.61 mm±0.30 mm. The population mean of stripping length in three groups was not all the same calculated by analysis of variance (P<0.01). There were significant differences in the stripping length of the three groups by the SNK test (P<0.05). The nickel-titanium dual-stage maxillary sinus mucosa stripper can achieve a larger mucosal stripping range. The stripper with a model of 0.014 has a moderate flexibility and safety, and it can strip a large area of sinus mucosa.
.

  4. Preliminary investigation of crack arrest in composite laminates containing buffer strips

    NASA Technical Reports Server (NTRS)

    Goree, J. G.

    1978-01-01

    The mechanical properties of some hybrid buffer strip laminates and the crack arrest potential of laminates containing buffer strips were determined. The hybrid laminates consisted of graphite with either S-glass, E-glass, or Kevlar. Unnotched tensile coupons and center-cracked fracture coupons were tested. Elastic properties, complete stress/strain curves, and critical stress intensity values are given. The measured elastic properties compare well with those calculated by classical lamination theory for laminates with linear stress/strain behavior. The glass hybrids had more delamination and higher fracture toughness than the all-graphite or the Kevlar hybrid.

  5. Embedded pitch adapters: A high-yield interconnection solution for strip sensors

    NASA Astrophysics Data System (ADS)

    Ullán, M.; Allport, P. P.; Baca, M.; Broughton, J.; Chisholm, A.; Nikolopoulos, K.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Kuczewski, P.; Lynn, D.; Hommels, L. B. A.; Fleta, C.; Fernandez-Tejero, J.; Quirion, D.; Bloch, I.; Díez, S.; Gregor, I. M.; Lohwasser, K.; Poley, L.; Tackmann, K.; Hauser, M.; Jakobs, K.; Kuehn, S.; Mahboubi, K.; Mori, R.; Parzefall, U.; Clark, A.; Ferrere, D.; Gonzalez Sevilla, S.; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; McMullen, T.; McEwan, F.; O'Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandić, I.; Mikuž, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Mikestikova, M.; Bevan, A.; Beck, G.; Milke, C.; Domingo, M.; Fadeyev, V.; Galloway, Z.; Hibbard-Lubow, D.; Liang, Z.; Sadrozinski, H. F.-W.; Seiden, A.; To, K.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Jinnouchi, O.; Hara, K.; Bernabeu, J.; Civera, J. V.; Garcia, C.; Lacasta, C.; Marti i Garcia, S.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.

    2016-09-01

    A proposal to fabricate large area strip sensors with integrated, or embedded, pitch adapters is presented for the End-cap part of the Inner Tracker in the ATLAS experiment. To implement the embedded pitch adapters, a second metal layer is used in the sensor fabrication, for signal routing to the ASICs. Sensors with different embedded pitch adapters have been fabricated in order to optimize the design and technology. Inter-strip capacitance, noise, pick-up, cross-talk, signal efficiency, and fabrication yield have been taken into account in their design and fabrication. Inter-strip capacitance tests taking into account all channel neighbors reveal the important differences between the various designs considered. These tests have been correlated with noise figures obtained in full assembled modules, showing that the tests performed on the bare sensors are a valid tool to estimate the final noise in the full module. The full modules have been subjected to test beam experiments in order to evaluate the incidence of cross-talk, pick-up, and signal loss. The detailed analysis shows no indication of cross-talk or pick-up as no additional hits can be observed in any channel not being hit by the beam above 170 mV threshold, and the signal in those channels is always below 1% of the signal recorded in the channel being hit, above 100 mV threshold. First results on irradiated mini-sensors with embedded pitch adapters do not show any change in the interstrip capacitance measurements with only the first neighbors connected.

  6. Patch testing with serial dilutions and thin-layer chromatograms of oak moss absolutes containing high and low levels of atranol and chloroatranol.

    PubMed

    Mowitz, Martin; Zimerson, Erik; Svedman, Cecilia; Bruze, Magnus

    2013-12-01

    Oak moss absolute (Evernia prunastri extract) contains a large number of substances, among them the potent allergens atranol and chloroatranol. Since 2008, their content in oak moss absolute has been restricted by the International Fragrance Association to a maximum level of 100 ppm each. To compare the elicitation capacities of a traditional (sample A) and a treated (sample B) oak moss absolute containing, in total, 27 000 and 66 ppm of atranol and chloroatranol, respectively, and to investigate reactions to components of oak moss absolute separated by thin-layer chromatography (TLC). Fifteen oak moss-allergic subjects were patch tested with serial dilutions and TLC strips of samples A and B. Fifteen subjects reacted to sample A at concentrations ≤ 2.0%, and 2 subjects reacted to sample B at 2.0% but not to lower concentrations. Among 13 subjects reacting to the TLC strip of sample A, 11 reacted to spots with retardation factor values corresponding to those of atranol and/or chloroatranol, and 11 reacted to other areas on the TLC strip. Only one subject reacted to the TLC strip of sample B. The patch test reactivity of sample B was significantly lower than that of sample A. The TLC patch tests indicate the presence of sensitizers other than atranol and chloroatranol in oak moss absolute. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. The Chemedian Brings Laughter to the Chemistry Classroom

    ERIC Educational Resources Information Center

    Weitkamp, Emma; Burnet, Frank

    2007-01-01

    "The Chemedian and the Crazy Football Match" is a comic strip developed by the authors to bring humor to aspects of the UK primary science curriculum. The comic strip was tested in six English primary school classes (years 3-5; ages 7-10); over 150 children participated in the project, together with six teachers. Children found the comic…

  8. Evaluation of Etest® strips for detection of KPC and metallo-carbapenemases in Enterobacteriaceae.

    PubMed

    Girlich, Delphine; Halimi, Diane; Zambardi, Gilles; Nordmann, Patrice

    2013-11-01

    The performance of Etest KPC and MBL strips (bioMérieux) was evaluated as compared to other phenotypic tests for detecting carbapenemases of the KPC-type and metallo-β-lactamases, respectively, on 133 well-characterized enterobacterial isolates. KPC and meropenem-containing MP/MPI Etest had high sensitivity (>92 %) and specificity (>97 %). © 2013.

  9. Development of an immunochromatographic strip test for rapid detection of citrus yellow vein clearing virus.

    PubMed

    Bin, Yu; Li, Zhongan; Wu, Jianxiang; Wang, Xuefeng; Zhou, Yan; Li, Taisheng; Yang, Fangyun; Zhou, Changyong; Song, Zhen

    2018-02-01

    A rapid immunochromatographic strip (ICS) test for detection of citrus yellow vein clearing virus (CYVCV) was developed. The test is based on an antibody sandwich format and uses the monoclonal antibody (MAb) 1E1, which is specific for CYVCV. MAb 1E1 labeled with 30-nm colloidal gold particles was coated on a gold conjugate pad. A secondary goat anti-mouse IgG was coated on the surface of a nitrocellulose filter membrane (NC) as the control (C) line, while 1E1 was coated on the surface of the NC as the test (T) line. The ICS test was evaluated for specificity and sensitivity and then applied for virus detection in field samples. There was no cross-reaction with citrus tristeza virus (CTV), satsuma dwarf virus (SDV), citrus tatter leaf virus (CTLV), citrus exocortis viroid (CEVd), citrus mosaic virus (CiMV), citrus psorosis virus (CPV), citrus ringspot virus (RSV) or 'Candidatus Liberibacter asiaticus' (CLas). The ICS test was still able to detect CYVCV in tissue extracts at a dilution of 1: 320 (w/v), which is as efficient as the dot-ELISA assay. In general, the ICS assay is less expensive, faster and simpler to conduct than conventional CYVCV detection methods, so it may be useful for large-scale detection or monitoring of CYVCV.

  10. Clinical value of rapid urine trypsinogen-2 test strip, urinary trypsinogen activation peptide, and serum and urinary activation peptide of carboxypeptidase B in acute pancreatitis

    PubMed Central

    Sáez, Jesús; Martínez, Juan; Trigo, Celia; Sánchez-Payá, José; Compañy, Luis; Laveda, Raquel; Griñó, Pilar; García, Cristina; Pérez-Mateo, Miguel

    2005-01-01

    AIM: To assess the usefulness of urinary trypsinogen-2 test strip, urinary trypsinogen activation peptide (TAP), and serum and urine concentrations of the activation peptide of carboxypeptidase B (CAPAP) in the diagnosis of acute pancreatitis. METHODS: Patients with acute abdominal pain and hospitalized within 24 h after the onset of symptoms were prospectively studied. Urinary trypsinogen-2 was considered positive when a clear blue line was observed (detection limit 50 μg/L). Urinary TAP was measured using a quantitative solid-phase ELISA, and serum and urinary CAPAP by a radioimmunoassay method. RESULTS: Acute abdominal pain was due to acute pancreatitis in 50 patients and turned out to be extrapancreatic in origin in 22 patients. Patients with acute pancreatitis showed significantly higher median levels of serum and urinary CAPAP levels, as well as amylase and lipase than extrapancreatic controls. Median TAP levels were similar in both groups. The urinary trypsinogen-2 test strip was positive in 68% of patients with acute pancreatitis and 13.6% in extrapancreatic controls (P<0.01). Urinary CAPAP was the most reliable test for the diagnosis of acute pancreatitis (sensitivity 66.7%, specificity 95.5%, positive and negative predictive values 96.6% and 56.7%, respectively), with a 14.6 positive likelihood ratio for a cut-off value of 2.32 nmol/L. CONCLUSION: In patients with acute abdominal pain, hospitalized within 24 h of symptom onset, CAPAP in serum and urine was a reliable diagnostic marker of acute pancreatitis. Urinary trypsinogen-2 test strip showed a clinical value similar to amylase and lipase. Urinary TAP was not a useful screening test for the diagnosis of acute pancreatitis. PMID:16437625

  11. Fatal exposure to methylene chloride among bathtub refinishers - United States, 2000-2011.

    PubMed

    2012-02-24

    In 2010, the Michigan Fatality Assessment and Control Evaluation program conducted an investigation into the death of a bathtub refinisher who used a methylene chloride-based paint stripping product marketed for use in aircraft maintenance. The program identified two earlier, similar deaths in Michigan. Program staff members notified CDC's National Institute for Occupational Safety and Health (NIOSH), which in turn notified the Occupational Safety and Health Administration (OSHA). In addition to the three deaths, OSHA identified 10 other bathtub refinisher fatalities associated with methylene chloride stripping agents that had been investigated in nine states during 2000-2011. Each death occurred in a residential bathroom with inadequate ventilation. Protective equipment, including a respirator, either was not used or was inadequate to protect against methylene chloride vapor, which has been recognized as potentially fatal to furniture strippers and factory workers but has not been reported previously as a cause of death among bathtub refinishers. Worker safety agencies, public health agencies, methylene chloride-based stripper manufacturers, and trade organizations should communicate the extreme hazards of using methylene chloride-based stripping products in bathtub refinishing to employers, workers, and consumers. Employers should strongly consider alternative methods of bathtub stripping and always ensure worker safety protections that reduce the risk for health hazards to acceptable levels. Employers choosing to use methylene chloride-based stripping products must comply with OSHA's standard to limit methylene chloride exposures to safe levels.

  12. Numerical and experimental investigation of strip deformation in cage roll forming process for pipes with low ratio of thickness/diameter

    NASA Astrophysics Data System (ADS)

    Kasaei, M. M.; Naeini, H. Moslemi; Tehrani, M. Salmani; Tafti, R. Azizi

    2011-01-01

    Cage roll forming is one of the advanced methods of cold roll forming process which is used widely for producing ERW pipes. In addition to decreasing the production cost and time, using cage roll forming provides smooth deformation on the strip. Few studies can be found about cage roll forming because of its complexity, and the available knowledge is experience-based more than science-based. In this paper, deformation of pipes with low ratio of thickness/diameter is investigated by 3D finite element simulation in Marc-Mentat software. Edge buckling defect in cage roll forming of low ratio of thickness/diameter pipes is very important. Due to direct influence of longitudinal strain on the edge buckling phenomenon, longitudinal strains at the edge and center line of the strip are investigated and high risk stands are introduced. The deformed strip is predicted using the simulation results and effects of each cage forming stage on the deformed strip profile are specified. In order to verify the simulation results, strip width and opening distance of the two edges in different forming stages are obtained from the simulations and compared with the experimental data which were measured from the production line. A good agreement between the experimental and simulated results is observed.

  13. Coupling fiber optics to a permeation liquid membrane for heavy metal sensor development.

    PubMed

    Ueberfeld, Jörn; Parthasarathy, Nalini; Zbinden, Hugo; Gisin, Nicolas; Buffle, Jacques

    2002-02-01

    We present the first sensing system for metal ions based on the combination of separation/preconcentration by a permeation liquid membrane (PLM) and fluorescence detection with an optical fiber. As a model, a system for the detection of Cu(II) ions was developed. The wall of a polypropylene hollow fiber serves as support for the permeable liquid membrane. The lumen of the fiber contains the strip solution in which Cu(II) is accumulated. Calcein, a fluorochromic dye, acts as stripping agent and at the same time as metal indicator. The quenching of the calcein fluorescence upon metal accumulation in the strip phase is detected with a multimode optical fiber, which is incorporated into the lumen. Fluorescence is excited with a blue LED and detected with a photon counter. Taking advantage of the high selectivity and sensitivity of PLM preconcentration, a detection limit for Cu(II) of approximately 50 nM was achieved. Among five tested heavy metal ions, Pb(II) was the only major interfering species. The incorporation of small silica optical fibers into the polypropylene capillary allows for real-time monitoring of the Cu(II) accumulation process.

  14. A strip chart recorder pattern recognition tool kit for Shuttle operations

    NASA Technical Reports Server (NTRS)

    Hammen, David G.; Moebes, Travis A.; Shelton, Robert O.; Savely, Robert T.

    1993-01-01

    During Space Shuttle operations, Mission Control personnel monitor numerous mission-critical systems such as electrical power; guidance, navigation, and control; and propulsion by means of paper strip chart recorders. For example, electrical power controllers monitor strip chart recorder pen traces to identify onboard electrical equipment activations and deactivations. Recent developments in pattern recognition technologies coupled with new capabilities that distribute real-time Shuttle telemetry data to engineering workstations make it possible to develop computer applications that perform some of the low-level monitoring now performed by controllers. The number of opportunities for such applications suggests a need to build a pattern recognition tool kit to reduce software development effort through software reuse. We are building pattern recognition applications while keeping such a tool kit in mind. We demonstrated the initial prototype application, which identifies electrical equipment activations, during three recent Shuttle flights. This prototype was developed to test the viability of the basic system architecture, to evaluate the performance of several pattern recognition techniques including those based on cross-correlation, neural networks, and statistical methods, to understand the interplay between an advanced automation application and human controllers to enhance utility, and to identify capabilities needed in a more general-purpose tool kit.

  15. Square-wave stripping voltammetric determination of caffeic acid on electrochemically reduced graphene oxide-Nafion composite film.

    PubMed

    Filik, Hayati; Çetintaş, Gamze; Avan, Asiye Aslıhan; Aydar, Sevda; Koç, Serkan Naci; Boz, İsmail

    2013-11-15

    An electrochemical sensor composed of Nafion-graphene nanocomposite film for the voltammetric determination of caffeic acid (CA) was studied. A Nafion graphene oxide-modified glassy carbon electrode was fabricated by a simple drop-casting method and then graphene oxide was electrochemically reduced over the glassy carbon electrode. The electrochemical analysis method was based on the adsorption of caffeic acid on Nafion/ER-GO/GCE and then the oxidation of CA during the stripping step. The resulting electrode showed an excellent electrocatalytical response to the oxidation of caffeic acid (CA). The electrochemistry of caffeic acid on Nafion/ER-GO modified glassy carbon electrodes (GCEs) were studied by cyclic voltammetry and square-wave adsorption stripping voltammetry (SW-AdSV). At optimized test conditions, the calibration curve for CA showed two linear segments: the first linear segment increased from 0.1 to 1.5 and second linear segment increased up to 10 µM. The detection limit was determined as 9.1×10(-8) mol L(-1) using SW-AdSV. Finally, the proposed method was successfully used to determine CA in white wine samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Developing a vacuum thermal stripping - acid absorption process for ammonia recovery from anaerobic digester effluent.

    PubMed

    Ukwuani, Anayo T; Tao, Wendong

    2016-12-01

    To prevent acetoclastic methanogens from ammonia inhibition in anaerobic digestion of protein-rich substrates, ammonia needs to be removed or recovered from digestate. This paper presents an innovative ammonia recovery process that couples vacuum thermal stripping with acid absorption. Ammonia is stripped out of digestate boiling at a temperature below the normal boiling point due to vacuum. Stripped ammonia is absorbed to a sulfuric acid solution, forming ammonium sulfate crystals as a marketable product. Three common types of digestate were found to have boiling point temperature-vacuum curves similar to water. Seven combinations of boiling temperature and vacuum (50 °C 16.6 kPa, 58 °C 20.0 kPa, 65 °C 25.1 kPa, 70 °C 33.6 kPa, 80 °C 54.0 kPa, 90 °C 74.2 kPa, and 100 °C 101.3 kPa) were tested for batch stripping of ammonia in dairy manure digestate. 93.3-99.9% of ammonia was stripped in 3 h. The Lewis-Whitman model fitted ammonia stripping process well. Ammonia mass transfer coefficient was significantly higher at boiling temperature 65-100 °C and vacuum pressure 25.1-101.3 kPa than 50-58 °C and 16.6-20.0 kPa. The low ammonia saturation concentrations (0-24 mg N/L) suggested a large driving force to strip ammonia. The optimum boiling point temperature - vacuum pressure for ammonia recovery in a recirculation line of a mesophilic digester was 65 °C and 25.1 kPa, at which the ammonia mass transfer coefficient was as high as 37.3 mm/h. Installation of a demister and liquid trap could avoid negative effects of higher stripping temperature and stronger vacuum on formation of ammonium sulfate crystals. Pilot tests demonstrated that high-purity ammonium sulfate crystals could be produced by controlling sulfuric acid content and maintaining acid solution saturated with ammonium sulfate. Although volatile organic compounds such as cyclohexene were found in the final acid solutions, no volatile organic compounds were found in the recovered crystals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Miscoding and other user errors: importance of ongoing education for proper blood glucose monitoring procedures.

    PubMed

    Schrock, Linda E

    2008-07-01

    This article reviews the literature to date and reports on a new study that documented the frequency of manual code-requiring blood glucose (BG) meters that were miscoded at the time of the patient's initial appointment in a hospital-based outpatient diabetes education program. Between January 1 and May 31, 2007, the type of BG meter and the accuracy of the patient's meter code (if required) and procedure for checking BG were checked during the initial appointment with the outpatient diabetes educator. If indicated, reeducation regarding the procedure for the BG meter code entry and/or BG test was provided. Of the 65 patients who brought their meter requiring manual entry of a code number or code chip to the initial appointment, 16 (25%) were miscoded at the time of the appointment. Two additional problems, one of dead batteries and one of improperly stored test strips, were identified and corrected at the first appointment. These findings underscore the importance of checking the patient's BG meter code (if required) and procedure for testing BG at each encounter with a health care professional or providing the patient with a meter that does not require manual entry of a code number or chip to match the container of test strips (i.e., an autocode meter).

  18. Multiplexed Lateral Flow Test for Detection and Differentiation of Cronobacter sakazakii Serotypes O1 and O2

    PubMed Central

    Scharinger, Eva J.; Dietrich, Richard; Wittwer, Tobias; Märtlbauer, Erwin; Schauer, Kristina

    2017-01-01

    The ubiquitous and opportunistic pathogen Cronobacter sakazakii is responsible for severe meningitis, sepsis, and necrotizing enterocolitis in neonates and infants associated with ingestion of contaminated powdered infant formula (PIF). The current ISO method for isolation and detection of Cronobacter spp. is laborious, time-consuming and expensive. In this study, a multiplexed lateral flow test strip was developed to rapidly detect and simultaneously serotype O1 and O2 C. sakazakii serotypes. The assay is based on two monoclonal antibodies (MAb) that specifically bind to the lipopolysaccharides (LPS) of these pathogens. The test strip provides results very quickly; C. sakazakii could be detected in pure culture within 15 min with a sensitivity of 107 CFU/ml. After non-selective enrichment for 18 h as low as one Cronobacter cell per g PIF could be detected. Moreover, the established lateral flow assay (LFA) offers excellent specificity showing no cross-reactivity with other C. sakazakii serotypes, Cronobacter species or Enterobacteriaceae tested. These characteristics, together with several advantages such as speed, simplicity in performance, low analysis cost, and no requirement of specialized skills or sophisticated equipment make the developed multiplexed LFA suitable for reliable detection and serotyping of C. sakazakii serotypes O1 and O2. PMID:28979257

  19. Multiplexed Lateral Flow Test for Detection and Differentiation of Cronobacter sakazakii Serotypes O1 and O2.

    PubMed

    Scharinger, Eva J; Dietrich, Richard; Wittwer, Tobias; Märtlbauer, Erwin; Schauer, Kristina

    2017-01-01

    The ubiquitous and opportunistic pathogen Cronobacter sakazakii is responsible for severe meningitis, sepsis, and necrotizing enterocolitis in neonates and infants associated with ingestion of contaminated powdered infant formula (PIF). The current ISO method for isolation and detection of Cronobacter spp. is laborious, time-consuming and expensive. In this study, a multiplexed lateral flow test strip was developed to rapidly detect and simultaneously serotype O1 and O2 C. sakazakii serotypes. The assay is based on two monoclonal antibodies (MAb) that specifically bind to the lipopolysaccharides (LPS) of these pathogens. The test strip provides results very quickly; C. sakazakii could be detected in pure culture within 15 min with a sensitivity of 10 7 CFU/ml. After non-selective enrichment for 18 h as low as one Cronobacter cell per g PIF could be detected. Moreover, the established lateral flow assay (LFA) offers excellent specificity showing no cross-reactivity with other C. sakazakii serotypes, Cronobacter species or Enterobacteriaceae tested. These characteristics, together with several advantages such as speed, simplicity in performance, low analysis cost, and no requirement of specialized skills or sophisticated equipment make the developed multiplexed LFA suitable for reliable detection and serotyping of C. sakazakii serotypes O1 and O2.

  20. Evaluation of low density polyethylene and nylon for delivery of synthetic mosquito attractants

    PubMed Central

    2012-01-01

    Background Synthetic odour baits present an unexploited potential for sampling, surveillance and control of malaria and other mosquito vectors. However, application of such baits is impeded by the unavailability of robust odour delivery devices that perform reliably under field conditions. In the present study the suitability of low density polyethylene (LDPE) and nylon strips for dispensing synthetic attractants of host-seeking Anopheles gambiae mosquitoes was evaluated. Methods Baseline experiments assessed the numbers of An. gambiae mosquitoes caught in response to low density polyethylene (LDPE) sachets filled with attractants, attractant-treated nylon strips, control LDPE sachets, and control nylon strips placed in separate MM-X traps. Residual attraction of An. gambiae to attractant-treated nylon strips was determined subsequently. The effects of sheet thickness and surface area on numbers of mosquitoes caught in MM-X traps containing the synthetic kairomone blend dispensed from LDPE sachets and nylon strips were also evaluated. Various treatments were tested through randomized 4 × 4 Latin Square experimental designs under semi-field conditions in western Kenya. Results Attractant-treated nylon strips collected 5.6 times more An. gambiae mosquitoes than LDPE sachets filled with the same attractants. The attractant-impregnated nylon strips were consistently more attractive (76.95%; n = 9,120) than sachets containing the same attractants (18.59%; n = 2,203), control nylon strips (2.17%; n = 257) and control LDPE sachets (2.29%; n = 271) up to 40 days post-treatment (P < 0.001). The higher catches of mosquitoes achieved with nylon strips were unrelated to differences in surface area between nylon strips and LDPE sachets. The proportion of mosquitoes trapped when individual components of the attractant were dispensed in LDPE sachets of optimized sheet thicknesses was significantly higher than when 0.03 mm-sachets were used (P < 0.001). Conclusion Nylon strips continuously dispense synthetic mosquito attractants several weeks post treatment. This, added to the superior performance of nylon strips relative to LDPE material in dispensing synthetic mosquito attractants, opens up the opportunity for showcasing the effectiveness of odour-baited devices for sampling, surveillance and control of disease vectors. PMID:22992518

  1. Evaluation of low density polyethylene and nylon for delivery of synthetic mosquito attractants.

    PubMed

    Mukabana, Wolfgang R; Mweresa, Collins K; Omusula, Philemon; Orindi, Benedict O; Smallegange, Renate C; van Loon, Joop Ja; Takken, Willem

    2012-09-19

    Synthetic odour baits present an unexploited potential for sampling, surveillance and control of malaria and other mosquito vectors. However, application of such baits is impeded by the unavailability of robust odour delivery devices that perform reliably under field conditions. In the present study the suitability of low density polyethylene (LDPE) and nylon strips for dispensing synthetic attractants of host-seeking Anopheles gambiae mosquitoes was evaluated. Baseline experiments assessed the numbers of An. gambiae mosquitoes caught in response to low density polyethylene (LDPE) sachets filled with attractants, attractant-treated nylon strips, control LDPE sachets, and control nylon strips placed in separate MM-X traps. Residual attraction of An. gambiae to attractant-treated nylon strips was determined subsequently. The effects of sheet thickness and surface area on numbers of mosquitoes caught in MM-X traps containing the synthetic kairomone blend dispensed from LDPE sachets and nylon strips were also evaluated. Various treatments were tested through randomized 4 × 4 Latin Square experimental designs under semi-field conditions in western Kenya. Attractant-treated nylon strips collected 5.6 times more An. gambiae mosquitoes than LDPE sachets filled with the same attractants. The attractant-impregnated nylon strips were consistently more attractive (76.95%; n = 9,120) than sachets containing the same attractants (18.59%; n = 2,203), control nylon strips (2.17%; n = 257) and control LDPE sachets (2.29%; n = 271) up to 40 days post-treatment (P < 0.001). The higher catches of mosquitoes achieved with nylon strips were unrelated to differences in surface area between nylon strips and LDPE sachets. The proportion of mosquitoes trapped when individual components of the attractant were dispensed in LDPE sachets of optimized sheet thicknesses was significantly higher than when 0.03 mm-sachets were used (P < 0.001). Nylon strips continuously dispense synthetic mosquito attractants several weeks post treatment. This, added to the superior performance of nylon strips relative to LDPE material in dispensing synthetic mosquito attractants, opens up the opportunity for showcasing the effectiveness of odour-baited devices for sampling, surveillance and control of disease vectors.

  2. Theoretical Investigation of the Interfacial Reactions during Hot-Dip Galvanizing of Steel

    NASA Astrophysics Data System (ADS)

    Mandal, G. K.; Balasubramaniam, R.; Mehrotra, S. P.

    2009-03-01

    In the modern galvanizing line, as soon as the steel strip enters the aluminum-containing zinc bath, two reactions occur at the strip and the liquid-zinc alloy interface: (1) iron rapidly dissolves from the strip surface, raising the iron concentration in the liquid phase at the strip-liquid interface; and (2) aluminum forms a stable aluminum-iron intermetallic compound layer at the strip-coating interface due to its greater affinity toward iron. The main objective of this study is to develop a simple and realistic mathematical model for better understanding of the kinetics of galvanizing reactions at the strip and the liquid-zinc alloy interface. In the present study, a model is proposed to simulate the effect of various process parameters on iron dissolution in the bath, as well as, aluminum-rich inhibition layer formation at the substrate-coating interface. The transient-temperature profile of the immersed strip is predicted based on conductive and convective heat-transfer mechanisms. The inhibition-layer thickness at the substrate-coating interface is predicted by assuming the cooling path of the immersed strip consists of a series of isothermal holds of infinitesimal time-step. The influence of galvanizing reaction is assessed by considering nucleation and growth mechanisms at each hold time, which is used to estimate the total effect of the immersion time on the formation mechanism of the inhibition layer. The iron- dissolution model is developed based on well established principles of diffusion taking into consideration the area fraction covered by the intermetallic on the strip surface during formation of the inhibition layer. The model can be effectively used to monitor the dross formation in the bath by optimizing the process parameters. Theoretical predictions are compared with the findings of other researchers. Simulated results are in good agreement with the theoretical and experimental observation carried out by other investigators.

  3. Development of a method for detecting trace metals in aqueous solutions based on the coordination chemistry of hexahydrotriazines.

    PubMed

    Wojtecki, Rudy J; Yuen, Alexander Y; Zimmerman, Thomas G; Jones, Gavin O; Horn, Hans W; Boday, Dylan J; Hedrick, James L; García, Jeannette M

    2015-08-07

    The detection of trace amounts (<10 ppb) of heavy metals in aqueous solutions is described using 1,3,5-hexahydro-1,3,5-triazines (HTs) as chemical indicators and a low cost fluorimeter-based detection system. This method takes advantage of the inherent properties of HTs to coordinate strongly with metal ions in solution, a fundamental property that was studied using a combination of analytical tools (UV-Vis titrations, (1)H-NMR titrations and computational modeling). Based on these fundamental studies that show significant changes in the HT UV signature when a metal ion is present, HT compounds were used to prepare indicator strips that resulted in significant fluorescence changes when a metal was present. A portable and economical approach was adopted to test the concept of utilizing HTs to detect heavy metals using a fluorimeter system that consisted of a low-pressure mercury lamp, a photo-detector, a monolithic photodiode and an amplifier, which produces a voltage proportional to the magnitude of the visible fluorescence emission. Readings of the prepared HT test strips were evaluated by exposure to two different heavy metals at the safe threshold concentration described by the U.S. Environmental Protection Agency (EPA) for Cr(3+) and Ag(2+) (100 μg L(-1) and 6.25, respectively). This method of detection could be used to the presence of either metal at these threshold concentrations.

  4. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    PubMed Central

    2015-01-01

    Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001) reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children. PMID:27335975

  5. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  6. Chest tube stripping in pediatric oncology patients: an experimental study.

    PubMed

    Oakes, L L; Hinds, P; Rao, B; Bozeman, P; Taylor, B; Stokes, D; Fairclough, D

    1993-07-01

    Stripping of chest tubes to promote drainage of the thorax of postthoracotomy patients has been routine practice, based on tradition. Recent published findings indicate that significant negative pressures are generated in the tube during stripping that could cause pain, bleeding and possible damage to the patient's lung tissue. To determine whether pediatric oncology patients whose chest tubes were not stripped would differ in frequency of pain, fever or lung complications from patients who underwent routine tube stripping. Data were collected at multiple points during the first 72-hour postoperative period from 16 patients assigned to the stripped or unstripped groups. Pain was measured by the Faces Pain Scale and the Visual Analogue Scale; temperature, by electronic thermometer; and lung complications, by stethoscope and radiographs. Both groups, which were comparable for age, primary diagnosis and prior history of lung problems, received identical supportive nursing and medical care, with the physicians blind to group assignment. The two groups did not differ significantly in frequency of pain, incidence of fever, breath sounds or radiographic findings across measurement points. A strong correlation was found between the pain scores using the two instruments. Patients whose tubes were not stripped did not have an increased risk of infection or lung complications. Study findings indicated that stripping did not increase the frequency of pain. Stripping of chest tubes as a routine postoperative measure is questioned.

  7. Getting More Power from Your Flowers: Multi-Functional Flower Strips Enhance Pollinators and Pest Control Agents in Apple Orchards

    PubMed Central

    Wilby, Andrew; Sutton, Peter; Wäckers, Felix

    2017-01-01

    Flower strips are commonly recommended to boost biodiversity and multiple ecosystem services (e.g., pollination and pest control) on farmland. However, significant knowledge gaps remain regards the extent to which they deliver on these aims. Here, we tested the efficacy of flower strips that targeted different subsets of beneficial arthropods (pollinators and natural enemies) and their ecosystem services in cider apple orchards. Treatments included mixes that specifically targeted: (1) pollinators (‘concealed-nectar plants’); (2) natural enemies (‘open-nectar plants’); or (3) both groups concurrently (i.e., ‘multi-functional’ mix). Flower strips were established in alleyways of four orchards and compared to control alleyways (no flowers). Pollinator (e.g., bees) and natural enemy (e.g., parasitoid wasps, predatory flies and beetles) visitation to flower strips, alongside measures of pest control (aphid colony densities, sentinel prey predation), and fruit production, were monitored in orchards over two consecutive growing seasons. Targeted flower strips attracted either pollinators or natural enemies, whereas mixed flower strips attracted both groups in similar abundance to targeted mixes. Natural enemy densities on apple trees were higher in plots containing open-nectar plants compared to other treatments, but effects were stronger for non-aphidophagous taxa. Predation of sentinel prey was enhanced in all flowering plots compared to controls but pest aphid densities and fruit yield were unaffected by flower strips. We conclude that ‘multi-functional’ flower strips that contain flowering plant species with opposing floral traits can provide nectar and pollen for both pollinators and natural enemies, but further work is required to understand their potential for improving pest control services and yield in cider apple orchards. PMID:28930157

  8. Getting More Power from Your Flowers: Multi-Functional Flower Strips Enhance Pollinators and Pest Control Agents in Apple Orchards.

    PubMed

    Campbell, Alistair John; Wilby, Andrew; Sutton, Peter; Wäckers, Felix

    2017-09-20

    Flower strips are commonly recommended to boost biodiversity and multiple ecosystem services (e.g., pollination and pest control) on farmland. However, significant knowledge gaps remain regards the extent to which they deliver on these aims. Here, we tested the efficacy of flower strips that targeted different subsets of beneficial arthropods (pollinators and natural enemies) and their ecosystem services in cider apple orchards. Treatments included mixes that specifically targeted: (1) pollinators ('concealed-nectar plants'); (2) natural enemies ('open-nectar plants'); or (3) both groups concurrently (i.e., 'multi-functional' mix). Flower strips were established in alleyways of four orchards and compared to control alleyways (no flowers). Pollinator (e.g., bees) and natural enemy (e.g., parasitoid wasps, predatory flies and beetles) visitation to flower strips, alongside measures of pest control (aphid colony densities, sentinel prey predation), and fruit production, were monitored in orchards over two consecutive growing seasons. Targeted flower strips attracted either pollinators or natural enemies, whereas mixed flower strips attracted both groups in similar abundance to targeted mixes. Natural enemy densities on apple trees were higher in plots containing open-nectar plants compared to other treatments, but effects were stronger for non-aphidophagous taxa. Predation of sentinel prey was enhanced in all flowering plots compared to controls but pest aphid densities and fruit yield were unaffected by flower strips. We conclude that 'multi-functional' flower strips that contain flowering plant species with opposing floral traits can provide nectar and pollen for both pollinators and natural enemies, but further work is required to understand their potential for improving pest control services and yield in cider apple orchards.

  9. A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

    PubMed

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Wyrwicz, Alice M; Li, Limin; Kao, C-M

    2015-06-01

    We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm 3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

  10. Effect of obese and lean Zucker rat sera on human and rat prostate cancer cells: implications in obesity-related prostate tumor biology.

    PubMed

    Lamarre, Neil S; Ruggieri, Michael R; Braverman, Alan S; Gerstein, Matthew I; Mydlo, Jack H

    2007-01-01

    Several reports have demonstrated the effects of obesity on prostate cancer. Also several reports have linked expression of vascular endothelial cell growth factor (VEGF) and basic fibroblast growth factor (FGF-2) to prostate cancer aggressiveness. The objective of this study was to determine whether a difference exists between lean and obese Zucker rat sera on proliferation prostate cancer cell lines, as well as to examine the differences in FGF-2 and VEGF concentrations. Ten-week-old female obese and lean Zucker rat sera were subjected to charcoal stripping and tested for the proliferation of human LNCaP and rat AT3B-1 prostate cancer cells. An acetonitrile extract of the charcoal used to strip the sera was also tested for mitogenicity. VEGF and FGF-2 concentrations were determined by enzyme-linked immunosorbent assay. Both unstripped and charcoal-stripped obese rat sera had a greater mitogenic effect than did the lean sera on the LNCaP cell line. Charcoal stripping of both obese and lean sera reduced the mitogenic effect on the AT3B-1 cell line. The acetonitrile extract of the charcoal used to strip the sera was unable to recover this proliferative effect. The concentration of VEGF was greater in the obese serum than in the lean serum, and charcoal stripping reduced the concentrations of both FGF-2 and VEGF. The finding of greater VEGF in obese rat sera, as well as greater mitogenic responses on human prostate cancer cells in vitro, suggests this as one of the many possible mechanisms involved in obesity-related prostate cancer biology.

  11. Confirmation of nasogastric tube position by pH testing.

    PubMed

    Taylor, S J; Clemente, R

    2005-10-01

    In 2004, the Medicines and Healthcare products Regulatory Agency (MHRA) advised that nasogastric (NG) tube position should be confirmed using pH strips or paper. However, gastric pH is raised by the use of H2-blockers and proton-pump inhibitors (PPIs) potentially producing false negative pH tests resulting in delayed feeding. In addition, colorimetric differentiation using pH strips may be more prone to bias and inaccuracy than direct pH measurements largely used to establish the threshold. To quantify this problem a 1 day survey of all the patients requiring NG and nasointestinal (NI) feeding was undertaken, to establish the numbers of patients receiving H2-Blockers or PPIs, with or without a safe swallow and the methods currently being used to confirm tube positioning. A second observational study was performed to establish the accuracy of six pH strips available to NHS trusts against four unlabelled pH solutions. Forty-two per cent of patients receiving NG feeding were on H2-blockers or PPIs, including 13% who had a safe swallow for acidic drinks that could be subsequently aspirated to confirm position. In the second study 'testers' correctly identified pH's 3, 4, 5 and 6 with Mackery-Nagel 0-6, BDH 0-6 and 0-14 strips but overestimated pH 4 as pH 5 with Johnson 0-11 paper, underestimated pH 6 as pH 5 with Pehanon 0-12 paper and with Litmus classified pH 3-5 as acid (all), but half also classified pH 6 as acid. Theoretically 29% of NG tube positions could not be confirmed by pH testing because of the usage of PPIs or H2-blockers and lack of swallow. Some pH strips are either inaccurate or their result misinterpreted by staff. Large surveys and trials of the actual efficacy and accuracy of pH testing are required.

  12. Cranial biomechanics of Diplodocus (Dinosauria, Sauropoda): testing hypotheses of feeding behaviour in an extinct megaherbivore

    NASA Astrophysics Data System (ADS)

    Young, Mark T.; Rayfield, Emily J.; Holliday, Casey M.; Witmer, Lawrence M.; Button, David J.; Upchurch, Paul; Barrett, Paul M.

    2012-08-01

    Sauropod dinosaurs were the largest terrestrial herbivores and pushed at the limits of vertebrate biomechanics and physiology. Sauropods exhibit high craniodental diversity in ecosystems where numerous species co-existed, leading to the hypothesis that this biodiversity is linked to niche subdivision driven by ecological specialisation. Here, we quantitatively investigate feeding behaviour hypotheses for the iconic sauropod Diplodocus. Biomechanical modelling, using finite element analysis, was used to examine the performance of the Diplodocus skull. Three feeding behaviours were modelled: muscle-driven static biting, branch stripping and bark stripping. The skull was found to be `over engineered' for static biting, overall experiencing low stress with only the dentition enduring high stress. When branch stripping, the skull, similarly, is under low stress, with little appreciable difference between those models. When simulated for bark stripping, the skull experiences far greater stresses, especially in the teeth and at the jaw joint. Therefore, we refute the bark-stripping hypothesis, while the hypotheses of branch stripping and/or precision biting are both consistent with our findings, showing that branch stripping is a biomechanically plausible feeding behaviour for diplodocids. Interestingly, in all simulations, peak stress is observed in the premaxillary-maxillary `lateral plates', supporting the hypothesis that these structures evolved to dissipate stress induced while feeding. These results lead us to conclude that the aberrant craniodental form of Diplodocus was adapted for food procurement rather than resisting high bite forces.

  13. On the Formation of Ultra-Difuse Galaxies as Tidally-Stripped Systems

    NASA Astrophysics Data System (ADS)

    Carleton, Timothy; Cooper, Michael; Kaplinghat, Manoj; Errani, Raphael; Penarrubia, Jorge

    2018-01-01

    The recent identification of a large population of so-called 'Ultra-Diffuse' Galaxies (UDGs), with stellar masses ~108 M⊙, but half light radii over 1.5 kpc, has challenged our understanding of galaxy evolution. Motivated by the environmental dependence of UDG properties and abundance, I present a model for the formation of UDGs through tidal-stripping of dwarf galaxies in cored dark matter halos. To test this scenario, I utilize results from simulations of tidal stripping, which demonstrate that changes in the stellar profile of a tidally stripped galaxy can be written as a function of the amount of tidal stripping experienced by the halo (tidal tracks). These tracks, however, are different for cored and cuspy halos. Additional simulations show how the halo responds to tidal interactions given the halo orbit within a cluster.In particular, dwarf elliptical galaxies, born in 1010-10.5 M⊙ halos, expand significantly as a result of tidal stripping and produce UDGs. Applying these models to the population of halos in the Bolshoi simulation, I am able to follow the effects of tidal stripping on the dwarf galaxy population in clusters. Using tidal tracks for cuspy halos does not reproduce the observed properties of UDGs. However, using the tidal tracks for cored halos, I reproduce the distribution of sizes, stellar masses, and abundance of UDGs in clusters remarkably well.

  14. Thermoelectrically controlled device for studies of temperature-induced corneal shrinkage

    NASA Astrophysics Data System (ADS)

    Borja, David; Manns, Fabrice; Fernandez, Viviana; Lamar, Peggy; Soederberg, Per G.; Parel, Jean-Marie A.

    2002-06-01

    The purpose of this study was to design and calibrate a device to measure the dynamics of thermal shrinkage in corneal and scleral strips. The apparatus consists of a thermoelectric cell controlled by a temperature controller designed to generate temperatures up to 90 degree(s)C in rectangular corneal strips; a copper cuvette filled with Dextran solution that holds the corneal strip and a displacement sensor that measures the change in length of the tissue during heat-induced shrinkage. The device was tested on corneal tissue from Florida Eye-Bank eyes that were cut into 2x4mm rectangular strips. Preliminary results indicate that our system can reproducibly create and accurately measure thermally induced corneal shrinkage. Shrinkage experiments will be used to optimize laser parameters for corneal shrinkage during laser thermokeratoplasty and laser scleral buckling.

  15. Ultra-wide acoustic band gaps in pillar-based phononic crystal strips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coffy, Etienne, E-mail: etienne.coffy@femto-st.fr; Lavergne, Thomas; Addouche, Mahmoud

    2015-12-07

    An original approach for designing a one dimensional phononic crystal strip with an ultra-wide band gap is presented. The strip consists of periodic pillars erected on a tailored beam, enabling the generation of a band gap that is due to both Bragg scattering and local resonances. The optimized combination of both effects results in the lowering and the widening of the main band gap, ultimately leading to a gap-to-midgap ratio of 138%. The design method used to improve the band gap width is based on the flattening of phononic bands and relies on the study of the modal energy distributionmore » within the unit cell. The computed transmission through a finite number of periods corroborates the dispersion diagram. The strong attenuation, in excess of 150 dB for only five periods, highlights the interest of such ultra-wide band gap phononic crystal strips.« less

  16. Numerical procedure to determine geometric view factors for surfaces occluded by cylinders

    NASA Technical Reports Server (NTRS)

    Sawyer, P. L.

    1978-01-01

    A numerical procedure was developed to determine geometric view factors between connected infinite strips occluded by any number of infinite circular cylinders. The procedure requires a two-dimensional cross-sectional model of the configuration of interest. The two-dimensional model consists of a convex polygon enclosing any number of circles. Each side of the polygon represents one strip, and each circle represents a circular cylinder. A description and listing of a computer program based on this procedure are included in this report. The program calculates geometric view factors between individual strips and between individual strips and the collection of occluding cylinders.

  17. Strip-Search Case Testing Balance between Privacy, Student Safety

    ERIC Educational Resources Information Center

    Robelen, Erik W.

    2009-01-01

    As it weighs the high-profile case of a 13-year-old girl strip-searched at school, the U.S. Supreme Court is grappling with where to draw the line between protecting student privacy rights and allowing school officials to take steps to ensure a safe environment. During oral arguments, several of the justices seemed sympathetic to the challenges…

  18. ELISA and ImmunoStrip® for detection of Phytophthora ramorum, P. kernoviae, and other Phytophthora species

    Treesearch

    Francisco J. Avila; Barbara Schoedel; Z. Gloria Abad; Michael D. Coffey; Cheryl Blomquist

    2009-01-01

    The goal of this work was to develop improved tools for the detection of Phytophthora ramorum and P. kernoviae for field and the laboratory use. ImmunoStrip® and ELISA were selected as the test formats for development. Presently, the diagnosis of sudden oak death (SOD) in the national survey of P. ramorum ...

  19. Formula Gives Better Contact-Resistance Values

    NASA Technical Reports Server (NTRS)

    Lieneweg, Udo; Hannaman, David J.

    1988-01-01

    Lateral currents in contact strips taken into account. Four-terminal test structures added to intergrated circuits to enable measurement of interfacial resistivities of contacts between thin conducting layers. Thin-film model simplified quasi-two-dimensional potential model that accounts adequately for complicated three-dimensional, nonuniform current densitites. Effects of nonuniformity caused by lateral current flow in strips summarized in equivalent resistance Rs and voltage Vs.

  20. Anodic stripping voltammetry of gold nanoparticles at boron-doped diamond electrodes and its application in immunochromatographic strip tests.

    PubMed

    Ivandini, Tribidasari A; Wicaksono, Wiyogo P; Saepudin, Endang; Rismetov, Bakhadir; Einaga, Yasuaki

    2015-03-01

    Anodic stripping voltammetry (ASV) of colloidal gold-nanoparticles (AuNPs) was investigated at boron-doped diamond (BDD) electrodes in 50 mM HClO4. A deposition time of 300 s at-0.2 V (vs. Ag/AgCl) was fixed as the condition for the ASV. The voltammograms showed oxidation peaks that could be attributed to the oxidation of gold. These oxidation peaks were then investigated for potential application in immunochromatographic strip tests for the selective and quantitative detection of melamine, in which AuNPs were used as the label for the antibody of melamine. Linear regression of the oxidation peak currents appeared in the concentration range from 0.05-0.6 μg/mL melamine standard, with an estimated LOD of 0.069 μg/mL and an average relative standard deviation of 8.0%. This indicated that the method could be considered as an alternative method for selective and quantitative immunochromatographic applications. The validity was examined by the measurements of melamine injected into milk samples, which showed good recovery percentages during the measurements. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Fabrication, characterization and testing of silicon photomultipliers for the Muon Portal Project

    NASA Astrophysics Data System (ADS)

    La Rocca, P.; Billotta, S.; Blancato, A. A.; Bonanno, D.; Bonanno, G.; Fallica, G.; Garozzo, S.; Lo Presti, D.; Marano, D.; Pugliatti, C.; Riggi, F.; Romeo, G.; Santagati, G.; Valvo, G.

    2015-07-01

    The Muon Portal is a recently started Project aiming at the construction of a large area tracking detector that exploits the muon tomography technique to inspect the contents of traveling cargo containers. The detection planes will be made of plastic scintillator strips with embedded wavelength-shifting fibres. Special designed silicon photomultipliers will read the scintillation light transported by the fibres along the strips and a dedicated electronics will combine signals from different strips to reduce the overall number of channels, without loss of information. Different silicon photomultiplier prototypes, both with the p-on-n and n-on-p technologies, have been produced by STMicroelectronics during the last years. In this paper we present the main characteristics of the silicon photomultipliers designed for the Muon Portal Project and describe the setup and the procedure implemented for the characterization of these devices, giving some statistical results obtained from the test of a first batch of silicon photomultipliers.

  2. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    PubMed

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  3. An approach to the usage of polyethylene terephthalate (PET) waste as roadway pavement material.

    PubMed

    Gürü, Metin; Çubuk, M Kürşat; Arslan, Deniz; Farzanian, S Ali; Bilici, İbrahim

    2014-08-30

    This study investigates an application area for Polyethylene Terephthalate (PET) bottle waste which has become an environmental problem in recent decades as being a considerable part of the total plastic waste bulk. Two novel additive materials, namely Thin Liquid Polyol PET (TLPP) and Viscous Polyol PET (VPP), were chemically derived from waste PET bottles and used to modify the base asphalt separately for this aim. The effects of TLPP and VPP on the asphalt and hot mix asphalt (HMA) mixture properties were detected through conventional tests (Penetration, Softening Point, Ductility, Marshall Stability, Nicholson Stripping) and Superpave methods (Rotational Viscosity, Dynamic Shear Rheometer (DSR), Bending Beam Rheometer (BBR)). Also, chemical structures were described by Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS) and Fourier Transform Infrared (FTIR) techniques. Since TLPP and VPP were determined to improve the low temperature performance and fatigue resistance of the asphalt as well as the Marshall Stability and stripping resistance of the HMA mixtures based on the results of the applied tests, the usage of PET waste as an asphalt roadway pavement material offers an alternative and a beneficial way of disposal of this ecologically hazardous material. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Test of a single module of the J-PET scanner based on plastic scintillators

    NASA Astrophysics Data System (ADS)

    Moskal, P.; Niedźwiecki, Sz.; Bednarski, T.; Czerwiński, E.; Kapłon, Ł.; Kubicz, E.; Moskal, I.; Pawlik-Niedźwiecka, M.; Sharma, N. G.; Silarski, M.; Zieliński, M.; Zoń, N.; Białas, P.; Gajos, A.; Kochanowski, A.; Korcyl, G.; Kowal, J.; Kowalski, P.; Kozik, T.; Krzemień, W.; Molenda, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Salabura, P.; Słomski, A.; Smyrski, J.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.

    2014-11-01

    A Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this paper we report on tests of a single detection module built out from the BC-420 plastic scintillator strip (with dimensions of 5×19×300 mm3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50 ps intervals. The time resolution of the prototype module was established to be better than 80 ps (σ) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93 cm (σ) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to σ(E) / E ≈ 0.044 /√{ E(MeV) } and corresponds to the σ(E) / E of 7.5% at the Compton edge.

  5. ERTS-1 data applied to strip mining

    NASA Technical Reports Server (NTRS)

    Anderson, A. T.; Schubert, J.

    1976-01-01

    Two coal basins within the western region of the Potomac River Basin contain the largest strip-mining operations in western Maryland and West Virginia. The disturbed strip-mine areas were delineated along with the surrounding geological and vegetation features by using ERTS-1 data in both analog and digital form. The two digital systems employed were (1) the ERTS analysis system, a point-by-point digital analysis of spectral signatures based on known spectral values and (2) the LARS automatic data processing system. These two systems aided in efforts to determine the extent and state of strip mining in this region. Aircraft data, ground-verification information, and geological field studies also aided in the application of ERTS-1 imagery to perform an integrated analysis that assessed the adverse effects of strip mining. The results indicated that ERTS can both monitor and map the extent of strip mining to determine immediately the acreage affected and to indicate where future reclamation and revegetation may be necessary.

  6. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    PubMed Central

    Economou, Anastasios

    2018-01-01

    This work reviews the field of screen-printed electrodes (SPEs) modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of “green” metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned. PMID:29596391

  7. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    PubMed

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  8. Technical performance of lactate biosensors and a test-strip device during labour.

    PubMed

    Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W

    2010-04-01

    Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an increase of SD and coefficient of variation in all devices. This results in the important preanalytical finding that the precision of replicated measurements worsens significantly with time. The clinician should be aware of the type of analyser used and of preanalytical biases before making clinical decisions on the basis of lactate values.

  9. SNaPshot and StripAssay as Valuable Alternatives to Direct Sequencing for KRAS Mutation Detection in Colon Cancer Routine Diagnostics

    PubMed Central

    Fariña Sarasqueta, Arantza; Moerland, Elna; de Bruyne, Hanneke; de Graaf, Henk; Vrancken, Tamara; van Lijnschoten, Gesina; van den Brule, Adriaan J.C.

    2011-01-01

    Although direct sequencing is the gold standard for KRAS mutation detection in routine diagnostics, it remains laborious, time consuming, and not very sensitive. Our objective was to evaluate SNaPshot and the KRAS StripAssay as alternatives to sequencing for KRAS mutation detection in daily practice. KRAS exon 2–specific PCR followed by sequencing or by a SNaPshot reaction was performed. For the StripAssay, a mutant-enriched PCR was followed by hybridization to KRAS-specific probes bound to a nitrocellulose strip. To test sensitivities, dilution series of mutated DNA in wild-type DNA were made. Additionally, direct sequencing and SNaPshot were evaluated in 296 colon cancer samples. Detection limits of direct sequencing, SNaPshot, and StripAssay were 20%, 10%, and 1% tumor cells, respectively. Direct sequencing and SNaPshot can detect all 12 mutations in KRAS codons 12 and 13, whereas the StripAssay detects 10 of the most frequent ones. Workload and time to results are comparable for SNaPshot and direct sequencing. SNaPshot is flexible and easy to multiplex. The StripAssay is less time consuming for daily laboratory practice. SNaPshot is more flexible and slightly more sensitive than direct sequencing. The clinical evaluation showed comparable performances between direct sequencing and SNaPshot. The StripAssay is rapid and an extremely sensitive assay that could be considered when few tumor cells are available. However, found mutants should be confirmed to avoid risk of false positives. PMID:21354055

  10. A pilot study to assess if urine specific gravity and urine colour charts are useful indicators of dehydration in acute stroke patients.

    PubMed

    Rowat, Anne; Smith, Laura; Graham, Cat; Lyle, Dawn; Horsburgh, Dorothy; Dennis, Martin

    2011-09-01

    The purpose of this pilot study was to examine whether urine specific gravity and urine colour could provide an early warning of dehydration in stroke patients compared with standard blood indicators of hydration status. Dehydration after stroke has been associated with increased blood viscosity, venous thrombo-embolism and stroke mortality at 3-months. Earlier identification of dehydration might allow us to intervene to prevent significant dehydration developing or reduce its duration to improve patient outcomes. We recruited 20 stroke patients in 2007 and measured their urine specific gravity with urine test strips, a refractometer, and urine colour of specimens taken daily on 10 consecutive days and compared with the routine blood urea:creatinine ratios over the same period to look for trends and relationships over time. The agreement between the refractometer, test strips and urine colour were expressed as a percentage with 95% confidence intervals. Nine (45%) of the 20 stroke patients had clinical signs of dehydration and had a significantly higher admission median urea:creatinine ratio (P = 0·02, Mann-Whitney U-test). There were no obvious relationships between urine specific gravity and urine colour with the urea:creatinine ratio. Of the 174 urine samples collected, the refractometer agreed with 70/174 (40%) urine test strip urine specific gravity and 117/174 (67%) urine colour measurements. Our results do not support the use of the urine test strip urine specific gravity as an early indicator of dehydration. Further research is required to develop a practical tool for the early detection of dehydration in stroke patients. © 2011 Blackwell Publishing Ltd.

  11. Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washington, A. L. II; Peters, T. B.

    This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tankmore » 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or D Cs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction D Cs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.« less

  12. A Search for Ram-pressure Stripping in the Hydra I Cluster

    NASA Technical Reports Server (NTRS)

    Brown, B.

    2005-01-01

    Ram-pressure stripping is a method by which hot interstellar gas can be removed from a galaxy moving through a group or cluster of galaxies. Indirect evidence of ram-pressure stripping includes lowered X-ray brightness in a galaxy due to less X-ray emitting gas remaining in the galaxy. Here we present the initial results of our program to determine whether cluster elliptical galaxies have lower hot gas masses than their counterparts in less rich environments. This test requires the use of the high-resolution imaging of the Chandra Observatory and we present our analysis of the galaxies in the nearby cluster Hydra I.

  13. A Search for Ram-pressure Stripping in the Hydra I Cluster

    NASA Technical Reports Server (NTRS)

    Brown, B. A.

    2005-01-01

    Ram-pressure stripping is a method by which hot interstellar gas can be removed from a galaxy moving through a group or cluster of galaxies. Indirect evidence of ram-pressure stripping includes lowered X- ray brightness in a galaxy due to less X-ray emitting gas remaining in the galaxy. Here we present the initial results of our program to determine whether cluster elliptical galaxies have lower hot gas masses than their counterparts in less rich environments. This test requires the use of the high-resolution imaging of the Chundru Observatory and we present our analysis of the galaxies in the nearby cluster Hydra I.

  14. Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berdnikov, V. V.; Somov, S. V.; Pentchev, L.

    A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

  15. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  16. Development of a 3D CZT detector prototype for Laue Lens telescope

    NASA Astrophysics Data System (ADS)

    Caroli, Ezio; Auricchio, Natalia; Del Sordo, Stefano; Abbene, Leonardo; Budtz-Jørgensen, Carl; Casini, Fabio; Curado da Silva, Rui M.; Kuvvetlli, Irfan; Milano, Luciano; Natalucci, Lorenzo; Quadrini, Egidio M.; Stephen, John B.; Ubertini, Pietro; Zanichelli, Massimiliano; Zappettini, Andrea

    2010-07-01

    We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (~19×8 mm2 area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coordinate. The 3D prototype will be made by packing 8 linear modules, each composed by one basic sensitive unit, bonded on a ceramic layer. The linear modules readout is provided by a custom front end electronics implementing a set of three RENA-3 for a total of 128 channels. The front-end electronics and the operating logics (in particular coincidence logics for polarisation measurements) are handled by a versatile and modular multi-parametric back end electronics developed using FPGA technology.

  17. Contrast cancellation technique applied to digital x-ray imaging using silicon strip detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avila, C.; Lopez, J.; Sanabria, J. C.

    2005-12-15

    Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated datamore » to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.« less

  18. Development of bunch shape monitor for high-intensity beam on the China ADS proton LINAC Injector II

    NASA Astrophysics Data System (ADS)

    Zhu, Guangyu; Wu, Junxia; Du, Ze; Zhang, Yong; Xue, Zongheng; Xie, Hongming; Wei, Yuan; Jing, Long; Jia, Huan

    2018-05-01

    The development, performance, and testing of the longitudinal bunch shape monitor, namely, the Fast Faraday Cup (FFC), are presented in this paper. The FFC is an invasive instrument controlled by a stepper motor, and its principle of operation is based on a strip line structure. The longitudinal bunch shape was determined by sampling a small part of the beam hitting the strip line through a 1-mm hole. The rise time of the detector reached 24 ps. To accommodate experiments that utilize high-intensity beams, the materials of the bunch shape monitor were chosen to sustain high temperatures. Water cooling was also integrated in the detector system to enhance heat transfer and prevent thermal damage. We also present an analysis of the heating caused by the beam. The bunch shape monitor has been installed and commissioned at the China ADS proton LINAC Injector II.

  19. AIS/DOE Technology Roadmap Program: Strip Casting: Anticipating New Routes To Steel Sheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prof. Alan W. Camb; Prof. Anthony Rollett

    2001-08-31

    To determine the potential for strip casting in the steel industry and to develop the fundamental knowledge necessary to allow the role of strip casting in the modern steel industry to be understood. Based upon a study of carbon steel strip castings that were either produced for the program at British Steel or were received from a pre-commercial production machine, the following conclusions were made. Strip casting of carbon steels is technically feasible for sheet material from slightly less than 1 mm thick to 3 mm thick, and, assuming that it is economically viable, it will be first applied inmore » carbon steel markets that do not require stringent surface quality or extensive forming. The potential of strip casting as a casting process to be developed for steel castings is very high as the cast strip has some very novel characteristics. Direct cast carbon strip has better surface quality, shape and profile than any other casting process currently available. The more rapidly solidified structure of direct cast strip tends to be strong with low ductility; however, with adequate thermal treatment, it is possible to develop a variety of properties from the same grade. The process is more amenable at this time to production tonnages per year of the order of 500,000 tons and as such will first find niche type applications. This technology is an additional technology for steel production and will be in addition to, rather than a replacement for, current casting machines.« less

  20. Design, Analysis, and On-Sun Evaluation of Reflective Strips Under Controlled Buckling

    NASA Technical Reports Server (NTRS)

    Jaworske, Donald A.; Sechkar, Edward A.; Colozza, Anthony J.

    2014-01-01

    Solar concentrators are envisioned for use in a variety of space-based applications, including applications involving in situ resource utilization. Identifying solar concentrators that minimize mass and cost are of great interest, especially since launch cost is driven in part by the mass of the payload. Concentrators must also be able to survive the wide temperature excursions on the lunar surface. Identifying smart structures which compensate for changes in concentrator geometry brought about by temperature extremes are of interest. Some applications may benefit from the ability to change the concentrators focal pattern at will. This paper addresses a method of designing a single reflective strip to produce a desired focal pattern through the use of controlled buckling. Small variations in the cross section over the length of the reflective strip influence the distribution of light in the focal region. A finite element method of analysis is utilized here which calculates the curve produced for a given strip cross section and axial load. Varying axial force and strip cross section over the length of the reflective strip provide a means of optimizing ray convergence in the focal region. Careful selection of a tapered cross section yields a reflective strip that approximates a parabola. An array of reflective strips under controlled buckling produces a light weight concentrator and adjustments in the compression of individual strips provide a means of compensating for temperature excursions or changing the focal pattern at will.

  1. Design, Analysis, and On-Sun Evaluation of Reflective Strips Under Controlled Buckling

    NASA Technical Reports Server (NTRS)

    Jaworske, D. A.; Sechkar, E. A.; Colozza, A. J.

    2014-01-01

    Solar concentrators are envisioned for use in a variety of space-based applications, including applications involving in situ resource utilization. Identifying solar concentrators that minimize mass and cost are of great interest, especially since launch cost is driven in part by the mass of the payload. Concentrators must also be able to survive the wide temperature excursions on the lunar surface. Identifying smart structures which compensate for changes in concentrator geometry brought about by temperature extremes are of interest. Some applications may benefit from the ability to change the concentrator's focal pattern at will. This paper addresses a method of designing a single reflective strip to produce a desired focal pattern through the use of controlled buckling. Small variations in the cross section over the length of the reflective strip influence the distribution of light in the focal region. A finite element method of analysis is utilized here which calculates the curve produced for a given strip cross section and axial load. Varying axial force and strip cross section over the length of the reflective strip provide a means of optimizing ray convergence in the focal region. Careful selection of a tapered cross section yields a reflective strip that approximates a parabola. An array of reflective strips under controlled buckling produces a light weight concentrator and adjustments in the compression of individual strips provide a means of compensating for temperature excursions or changing the focal pattern at will.

  2. An all solid-state, rolled strip pulse forming line with low impedance and compact structure

    NASA Astrophysics Data System (ADS)

    Yang, Shi; Zhong, Hui-Huang; Qian, Bao-Liang; Yang, Han-Wu

    2010-04-01

    An all solid-state and compact pulsed strip pulse forming line (PFL) is investigated both theoretically and experimentally. The electromagnetic field distribution and the pulse formation in the strip PFL are analyzed numerically. Based on the theoretical analysis and numerical results, a rolled strip PFL with output voltage of 20 kV, pulse duration of 230 ns, and characteristic impedance of 0.5 Ω was designed and manufactured. We use the Mylar film and copper as the dielectric and conductor of the strip PFL. The dimension of the strip line is 23 000×400×1.6 mm3 in the case in which the strip line is unrolled, and the strip line is finally rolled into a cylinder of diameter of 311 mm for the experiment. The dimension and weight are about ten times smaller than those of traditional dielectric (oil or pure water) PFL with the same electrical parameters. Two experiments were performed using the strip line. One was for a transmission line experiment, and the other was for a PFL experiment. In the experiment of transmission line, the transmission time of the voltage signal was 115 ns, and the signal had almost no distortion, which verified the design. In the PFL experiment, results gave a 17.8 kV, 270 ns (full width at half maximum) voltage pulse which was a quasisquare wave on the water load of 0.5 Ω. The current going through the load is about 35.6 kA.

  3. Host Galaxy Spectra of Stripped SN from the Palomar Transient Factory: SN Progenitor Diagnostics and the SN-GRB Connection

    NASA Astrophysics Data System (ADS)

    Modjaz, Maryam; Gal-Yam, Avishay; Arcavi, Iair

    2012-02-01

    Stripped core-collapse supernovae (Stripped SNe) are powerful cosmic engines that energize and enrich the ISM and that sometimes accompany GRBs, but the exact mass and metallicity range of their massive progenitors is not known, nor the detailed physics of the explosion. We propose to continue conducting the first uniform and statistically significant study of host galaxies of 60 stripped SNe from the same innovative, homogeneous and galaxy-unbiased survey Palomar Transient Factory in order to determine the environmental conditions that influence the various kinds of massive stellar deaths. By obtaining spectra of the immediate host environments of our sample of stripped SN, we will (1) measure local abundances in order to differentiate between the two progenitor scenarios for stripped SN and (2) derive stellar population ages, masses and star formation histories via detailed stellar population synthesis models. Moreover, we will test if natal chemical abundance has effects on basic SN characteristics, such as peak luminosity. Any observed trends will have ramifications on SN and GRB explosion models and imply important demographic SN considerations. Our dataset will provide a crucial complimentary set to host galaxy studies of long-duration GRBs and pave the way for host studies of transients and SN found via upcoming surveys such as LSST.

  4. Host Galaxy Spectra of Stripped SN from the Palomar Transient Factory: SN Progenitor Diagnostics and the SN-GRB Connection

    NASA Astrophysics Data System (ADS)

    Modjaz, Maryam; Gal-Yam, Avishay; Arcavi, Iair

    2011-02-01

    Stripped core-collapse supernovae (Stripped SN) are powerful cosmic engines that energize and enrich the ISM and that sometimes accompany GRBs, but the exact mass and metallicity range of their massive progenitors is not known, nor the detailed physics of the explosion. With the harvest of 50 stripped SN from the innovative survey Palomar Transient Factory, we propose to conduct the first uniform and statistically significant study with SN from the same homogeneous and galaxy-unbiased survey in order to determine the environmental conditions that influence the various kinds of massive stellar deaths. By obtaining spectra of the immediate host environments of our sample of stripped SN, we will (1) measure local abundances in order to differentiate between the two progenitor scenarios for stripped SN and (2) derive stellar population ages, masses and star formation histories via detailed stellar population synthesis models. Moreover, we will test if natal chemical abundance has effects on basic SN characteristics, such as peak luminosity. Any observed trends will have ramifications on SN and GRB explosion models and imply important demographic SN considerations. Our dataset will provide a crucial complimentary set to host galaxy studies of long-duration GRBs and pave the way for host studies of transients and SN found via upcoming surveys such as LSST.

  5. The dissimilar brazing of Kovar alloy to SiCp/Al composites using silver-based filler metal foil

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Xu, Dongxia; Zhai, Yahong; Niu, Jitai

    2017-09-01

    Aluminum metal matrix composites with high SiC content (60 vol.% SiCp/Al MMCs) were surface metallized with a Ni-P alloy coating, and vacuum brazing between the composites and Kovar alloy were performed using rapidly cooled Ag-22.0Cu-15.9In-10.86Sn-1.84Ti (wt%) foil. The effects of Ni-P alloy coating and brazing parameters on the joint microstructures and properties were researched by SEM, EDS, and single lap shear test, respectively. Results show that Ag-Al intermetallic strips were formed in the 6063Al matrix and filler metal layer because of diffusion, and they were arranged regularly and accumulated gradually as the brazing temperature was increased ( T/°C = 550-600) or the soaking time was prolonged ( t/min = 10-50). However, excessive strips would destroy the uniformity of seams and lead to a reduced bonding strength (at most 70 MPa). Using a Ni-P alloy coating, void free joints without those strips were obtained at 560 °C after 20 min soaking time, and a higher shear strength of 90 MPa was achieved. The appropriate interface reaction ( 2 μm transition layer) that occurred along the Ni-P alloy coating/filler metal/Kovar alloy interfaces resulted in better metallurgical bonding. In this research, the developed Ag-based filler metal was suitable for brazing the dissimilar materials of Ni-P alloy-coated SiCp/Al MMCs and Kovar alloy, and capable welding parameters were also broadened.

  6. Digital camera and smartphone as detectors in paper-based chemiluminometric genotyping of single nucleotide polymorphisms.

    PubMed

    Spyrou, Elena M; Kalogianni, Despina P; Tragoulias, Sotirios S; Ioannou, Penelope C; Christopoulos, Theodore K

    2016-10-01

    Chemi(bio)luminometric assays have contributed greatly to various areas of nucleic acid analysis due to their simplicity and detectability. In this work, we present the development of chemiluminometric genotyping methods in which (a) detection is performed by using either a conventional digital camera (at ambient temperature) or a smartphone and (b) a lateral flow assay configuration is employed for even higher simplicity and suitability for point of care or field testing. The genotyping of the C677T single nucleotide polymorphism (SNP) of methylenetetrahydropholate reductase (MTHFR) gene is chosen as a model. The interrogated DNA sequence is amplified by polymerase chain reaction (PCR) followed by a primer extension reaction. The reaction products are captured through hybridization on the sensing areas (spots) of the strip. Streptavidin-horseradish peroxidase conjugate is used as a reporter along with a chemiluminogenic substrate. Detection of the emerging chemiluminescence from the sensing areas of the strip is achieved by digital camera or smartphone. For this purpose, we constructed a 3D-printed smartphone attachment that houses inexpensive lenses and converts the smartphone into a portable chemiluminescence imager. The device enables spatial discrimination of the two alleles of a SNP in a single shot by imaging of the strip, thus avoiding the need of dual labeling. The method was applied successfully to genotyping of real clinical samples. Graphical abstract Paper-based genotyping assays using digital camera and smartphone as detectors.

  7. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    NASA Astrophysics Data System (ADS)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.

  8. A time-based front-end ASIC for the silicon micro strip sensors of the bar PANDA Micro Vertex Detector

    NASA Astrophysics Data System (ADS)

    Di Pietro, V.; Brinkmann, K.-Th.; Riccardi, A.; Ritman, J.; Rivetti, A.; Rolo, M. D.; Stockmanns, T.; Zambanini, A.

    2016-03-01

    The bar PANDA (Antiproton Annihilation at Darmstadt) experiment foresees many detectors for tracking, particle identification and calorimetry. Among them, the innermost is the MVD (Micro Vertex Detector) responsible for a precise tracking and the reconstruction of secondary vertices. This detector will be built from both hybrid pixel (two inner barrels and six forward disks) and double-sided micro strip (two outer barrels and outer rim of the last two disks) silicon sensors. A time-based approach has been chosen for the readout ASIC of the strip sensors. The PASTA (bar PANDA Strip ASIC) chip aims at high resolution time-stamping and charge information through the Time over Threshold (ToT) technique. It benefits from a Time to Digital Converter (TDC) allowing a time bin width down to 50 ps. The analog front-end was designed to serve both n-type and p-type strips and the performed simulations show remarkable performances in terms of linearity and electronic noise. The TDC consists of an analog interpolator, a digital local controller, and a digital global controller as the common back-end for all of the 64 channels.

  9. Taped Random Spectra for Reliability Demonstration Testing

    DTIC Science & Technology

    1981-04-01

    circuit , barrier strip terminals 9A and 9B. Closure of the normally-open contacts provides the gate current necessary to trigger the control TRIAC ... Circuit contains a TRIAC , DIAC, Reed Relay (R3) and the Tape Running Relay Driver. The Cam on/off switching is accomplished through the barrier strip...2-25 2I; Input Power Circuit .. .. .... ...... ...... ...... ........... 2-26 2-13 Typical Control Circuit

  10. Resistive-strips micromegas detectors with two-dimensional readout

    NASA Astrophysics Data System (ADS)

    Byszewski, M.; Wotschack, J.

    2012-02-01

    Micromegas detectors show very good performance for charged particle tracking in high rate environments as for example at the LHC. It is shown that two coordinates can be extracted from a single gas gap in these detectors. Several micromegas chambers with spark protection by resistive strips and two-dimensional readout have been tested in the context of the R&D work for the ATLAS Muon System upgrade.

  11. Second-year results of hybrid poplar test plantings on bituminous strip-mine spoils in Pennsylvania

    Treesearch

    Grant Davis

    1964-01-01

    During the period 1946-49, The Pennsylvania State University established 22 experimental plantings of trees and shrubs on strip-mine spoil banks in the Bituminous Region of Pennsylvania to determine which species were best suited for revegetating such sites. When 10-year growth on the experimental plots was evaluated, a clone of hybrid poplar was found to have outgrown...

  12. Development of a Novel Gas Pressurized Stripping Process-Based Technology for CO₂ Capture from Post-Combustion Flue Gases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Shiaoguo

    A novel Gas Pressurized Stripping (GPS) post-combustion carbon capture (PCC) process has been developed by Carbon Capture Scientific, LLC, CONSOL Energy Inc., Nexant Inc., and Western Kentucky University in this bench-scale project. The GPS-based process presents a unique approach that uses a gas pressurized technology for CO₂ stripping at an elevated pressure to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy usemore » and cost competitiveness over the MEA process. To meet project goals and objectives, a combination of experimental work, process simulation, and technical and economic analysis studies were applied. The project conducted individual unit lab-scale tests for major process components, including a first absorption column, a GPS column, a second absorption column, and a flasher. Computer simulations were carried out to study the GPS column behavior under different operating conditions, to optimize the column design and operation, and to optimize the GPS process for an existing and a new power plant. The vapor-liquid equilibrium data under high loading and high temperature for the selected amines were also measured. The thermal and oxidative stability of the selected solvents were also tested experimentally and presented. A bench-scale column-based unit capable of achieving at least 90% CO₂ capture from a nominal 500 SLPM coal-derived flue gas slipstream was designed and built. This integrated, continuous, skid-mounted GPS system was tested using real flue gas from a coal-fired boiler at the National Carbon Capture Center (NCCC). The technical challenges of the GPS technology in stability, corrosion, and foaming of selected solvents, and environmental, health and safety risks have been addressed through experimental tests, consultation with vendors and engineering analysis. Multiple rounds of TEA were performed to improve the GPS-based PCC process design and operation, and to compare the energy use and cost performance of a nominal 550-MWe supercritical pulverized coal (PC) plant among the DOE/NETL report Case 11 (the PC plant without CO₂ capture), the DOE/NETL report Case 12 (the PC plant with benchmark MEA-based PCC), and the PC plant using GPS-based PCC. The results reveal that the net power produced in the PC plant with GPS-based PCC is 647 MWe, greater than that of the Case 12 (550 MWe). The 20-year LCOE for the PC plant with GPS-based PCC is 97.4 mills/kWh, or 152% of that of the Case 11, which is also 23% less than that of the Case 12. These results demonstrate that the GPS-based PCC process is energy-efficient and cost-effective compared with the benchmark MEA process.« less

  13. Robotic Waterjet System

    NASA Technical Reports Server (NTRS)

    1996-01-01

    NASA needed a way to safely strip old paint and thermal protection material from reusable components from the Space Shuttle; to meet this requirement, Marshall Space Flight Center teamed with United Technologies' USBI Company and developed a stripping system based on hydroblasting. United Technology spun off a new company, Waterjet Systems, to commercialize and market the technology. The resulting ARMS (Automated Robotic Maintenance Systems), employ waterblasts at 55,000 pounds per square inch controlled by target-sensitive robots. The systems are used on aircraft and engine parts, and the newest application is on ships, where it not only strips but catches the ensuing wastewater. This innovation results in faster, cheaper stripping with less clean-up and reduced environmental impact.

  14. Development of a colloidal gold immunochromatographic strip for rapid detection of Streptococcus agalactiae in tilapia.

    PubMed

    Wen-de, Wu; Min, Li; Ming, Chen; Li-Ping, Li; Rui, Wang; Hai-Lan, Chen; Fu-Yan, Chen; Qiang, Mi; Wan-Wen, Liang; Han-Zhong, Chen

    2017-05-15

    A colloidal gold immunochromatographic strip was developed for rapid detection of Streptococcus agalactiae (S. agalactiae) infection in tilapia. The monoclonal antibodies (mAb) 4C12 and 3A9 were used to target S. agalactiae as colloidal gold-mAb conjugate and captured antibody, respectively. The colloidal gold immunochromatographic strip was assembled via routine procedures. Optimal pH and minimum antibody levels in the reaction system for gold colloidal-mAb 4C12 conjugation were pH 7.4 and 18μg/mL, respectively. Optimal concentrations of the captured antibody 3A9 and goat anti-mouse antibody were 0.6mg/mL and 2mg/mL, respectively. The sensitivity of the strip for detecting S. agalactiae was 1.5×10 5 colony forming units (CFU). No cross-reaction was observed with other commonly encountered bacteria, including Pseudomonas fluorescens, Aeromonas hydrophila, Vibrio anguillarum and Streptococcus iniae. The assay time for S. agalactiae was less than 15min. Tilapia samples artificially infected with S. agalactiae were tested using the newly developed strip. The results indicated that blood, brain, kidney, spleen, metanephros and intestine specimens of infected fish can be used for S. agalactiae detection. The validity of the strip was maintained for 6 months at 4°C. These findings suggested that the immunochromatographic strip was effective for spot and rapid detection of S. agalactiae infected tilapia. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Technique for microswitch manufacture

    NASA Technical Reports Server (NTRS)

    Kitamura, T.; Kiyoyama, S.

    1983-01-01

    A five-step technique for microswitch manufacture is described: (1) A clad board is inlaid with a precious metal and the board is pressed. (2) One end of the fixed contact containing a precious metal inlay section is curved, and this edge of the precious metal inlay section becomes a fixed contact. (3) Inserts are formed in the unit body and terminal strips are placed through the top and bottom of the base and held. (4) The unit body is held by the base and the sequential contact strips are cut off. (5) Movable stripes are attached to the support of the terminal strips on the movable side and movable contacts are placed opposite the fixed contacts.

  16. Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system

    NASA Astrophysics Data System (ADS)

    De Cesare, M.; De Cesare, N.; D'Onofrio, A.; Gialanella, L.; Terrasi, F.

    2015-04-01

    Accelerator Mass Spectrometry (AMS) is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE) in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10-11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E) system with a 16-strip silicon detector (4.9×10-12 just with one strip).

  17. High efficiency laser-assisted H - charge exchange for microsecond duration beams

    DOE PAGES

    Cousineau, Sarah; Rakhman, Abdurahim; Kay, Martin; ...

    2017-12-26

    Laser-assisted stripping is a novel approach to H - charge exchange that overcomes long-standing limitations associated with the traditional, foil-based method of producing high-intensity, time-structured beams of protons. This paper reports on the first successful demonstration of the laser stripping technique for microsecond duration beams. The experiment represents a factor of 1000 increase in the stripped pulse duration compared with the previous proof-of-principle demonstration. The central theme of the experiment is the implementation of methods to reduce the required average laser power such that high efficiency stripping can be accomplished for microsecond duration beams using conventional laser technology. In conclusion,more » the experiment was performed on the Spallation Neutron Source 1 GeV H - beam using a 1 MW peak power UV laser and resulted in ~95% stripping efficiency.« less

  18. High efficiency laser-assisted H - charge exchange for microsecond duration beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cousineau, Sarah; Rakhman, Abdurahim; Kay, Martin

    Laser-assisted stripping is a novel approach to H - charge exchange that overcomes long-standing limitations associated with the traditional, foil-based method of producing high-intensity, time-structured beams of protons. This paper reports on the first successful demonstration of the laser stripping technique for microsecond duration beams. The experiment represents a factor of 1000 increase in the stripped pulse duration compared with the previous proof-of-principle demonstration. The central theme of the experiment is the implementation of methods to reduce the required average laser power such that high efficiency stripping can be accomplished for microsecond duration beams using conventional laser technology. In conclusion,more » the experiment was performed on the Spallation Neutron Source 1 GeV H - beam using a 1 MW peak power UV laser and resulted in ~95% stripping efficiency.« less

  19. Volatile fatty acids (VFAs) production from swine manure through short-term dry anaerobic digestion and its separation from nitrogen and phosphorus resources in the digestate.

    PubMed

    Huang, Weiwei; Huang, Wenli; Yuan, Tian; Zhao, Ziwen; Cai, Wei; Zhang, Zhenya; Lei, Zhongfang; Feng, Chuanping

    2016-03-01

    The sustainability of an agricultural system depends highly upon the recycling of all useful substances from agricultural wastes. This study explored the feasibility of comprehensive utilization of C, N and P resources in swine manure (SM) through short-term dry anaerobic digestion (AD) followed by dry ammonia stripping, aiming at achieving (1) effective total volatile fatty acids (VFAs) production and separation; (2) ammonia recovery from the digestate; and (3) preservation of high P bioavailability in the solid residue for further applications. Specifically, two ammonia stripping strategies were applied and compared in this work: (I) ammonia stripping was directly performed with the digestate from dry AD of SM (i.e. dry ammonia stripping); and (II) wet ammonia stripping was conducted by using the resultant filtrate from solid-liquid separation of the mixture of digestate and added water. Results showed that dry AD of the tested SM at 55 °C, 20% TS and unadjusted initial pH (8.6) for 8 days produced relatively high concentrations of total VFAs (94.4 mg-COD/g-VS) and ammonia-N (20.0 mg/g-VS) with high potentially bioavailable P (10.6 mg/g-TS) remained in the digestate, which was considered optimal in this study. In addition, high ammonia removal efficiencies of 96.2% and 99.7% were achieved through 3 h' dry and wet stripping (at 55 °C and initial pH 11.0), respectively, while the total VFAs concentration in the digestate/filtrate remained favorably unchanged. All experimental data from the two stripping processes well fitted to the pseudo first-order kinetic model (R(2) = 0.9916-0.9997) with comparable theoretical maximum ammonia removal efficiencies (Aeq, >90%) being obtained under the tested dry and wet stripping conditions, implying that the former was more advantageous due to its much higher volumetric total ammonia-N removal rate thus much smaller reactor volume, less energy/chemicals consumption and no foaming problems. After 8 days' dry AD and 3 h' dry ammonia stripping, the separated liquid containing VFAs and the recovered ammonia were both marketable products, and the solid residues with averagely higher C/N ratios of 25.7 than those of raw SM (18.0) meanwhile maintaining a relatively high bioavailable P content of 8.1 mg/g-TS can serve as better feedstock for methane fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Application of ultrasound and air stripping for the removal of aromatic hydrocarbons from spent sulfidic caustic for use in autotrophic denitrification as an electron donor.

    PubMed

    Lee, Jae-Ho; Park, Jeung-Jin; Choi, Gi-Choong; Byun, Im-Gyu; Park, Tae-Joo; Lee, Tae-Ho

    2013-01-01

    Spent sulfidic caustic (SSC) produced from petroleum industry can be reused to denitrify nitrate-nitrogen via a biological nitrogen removal process as an electron donor for sulfur-based autotrophic denitrification, because it has a large amount of dissolved sulfur. However, SSC has to be refined because it also contains some aromatic hydrocarbons, typically benzene, toluene, ethylbenzene, xylene (BTEX) and phenol that are recalcitrant organic compounds. In this study, laboratory-scale ultrasound irradiation and air stripping treatment were applied in order to remove these aromatic hydrocarbons. In the ultrasound system, both BTEX and phenol were exponentially removed by ultrasound irradiation during 60 min of reaction time to give the greatest removal efficiency of about 80%. Whereas, about 95% removal efficiency of BTEX was achieved, but not any significant phenol removal, within 30 min in the air stripping system, indicating that air stripping was a more efficient method than ultrasound irradiation. However, since air stripping did not remove any significant phenol, an additional process for degrading phenol was required. Accordingly, we applied a combined ultrasound and air stripping process. In these experiments, the removal efficiencies of BTEX and phenol were improved compared to the application of ultrasound and air stripping alone. Thus, the combined ultrasound and air stripping treatment is appropriate for refining SSC.

Top