Generating A Strobed Laser Light Sheet
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.; Franke, John M.; Rhodes, David B.; Jones, Stephen B.
1994-01-01
An optoelectronic system generating synchronous, strobed sheet of laser light developed for use in making visible flow of air about model helicopter rotor. Used in wind-tunnel tests to determine actual locations of vortices for comparison with locations predicted by mathematical models to validate models. Each blade tip produces vortex. By establishing successive vortex locations, researcher determines trajectory of vortex pattern. Light-sheet strobe circuits provide selection of blade positions, strobe-pulse durations, and multiple pulses per revolution for rotors having two to nine blades. To make flow visible, vaporizing propylene glycol injected upstream of model. System also provides calibrated trigger delay of strobe pulses, adjustable strobe-pulse durations, selectable number of blades, and slip-sync mode to make flow visible as though in slow motion.
Strobe Traffic Lights Warn of Approaching Emergency Vehicles
NASA Technical Reports Server (NTRS)
Bachelder, Aaron
2004-01-01
Strobe-enhanced traffic signals have been developed to aid in the preemption of road intersections for emergency vehicles. The strobe-enhanced traffic signals can be incorporated into both new and pre-existing traffic-control systems in which the traffic-signal heads are of a relatively new type based on arrays of light-emitting diodes (LEDs). The strobe-enhanced traffic signals offer a less expensive, less complex alternative to a recently developed system of LED-based warning signs placed next to traffic signals. Because of its visual complexity, the combination of traffic signals and warning signs is potentially confusing to motorists. The strobe-enhanced traffic signals present less visual clutter. In a given traffic-signal head, the strobe-enhanced traffic signal is embedded in the red LED array of the stop signal. Two strobe LED strips one horizontal and one vertical are made capable of operating separately from the rest of the red LED matrix. When no emergency vehicle is approaching, the red LED array functions as a normal stop signal: all the red LEDs are turned on and off together. When the intersection is to be preempted for an approaching emergency vehicle, only the LEDs in one of the strobe strips are lit, and are turned on in a sequence that indicates the direction of approach. For example (see figure), if an emergency vehicle approaches from the right, the strobe LEDs are lit in a sequence moving from right to left. Important to the success of strobe-enhanced traffic signals is conformance to city ordinances and close relation to pre-existing traffic standards. For instance, one key restriction is that new icons must not include arrows, so that motorists will not confuse new icons with conventional arrows that indicate allowed directions of movement. It is also critical that new displays like strobe-enhanced traffic signals be similar to displays used in traffic-control systems in large cities. For example, Charleston, South Carolina uses horizontal strobes on red traffic lights to alert motorists and thereby help motorists not to miss red lights. The one significant potential disadvantage of strobe-enhanced traffic lights is initial unfamiliarity on the part of motorists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, M.; McKinstry, C.; Cook, C.
Since 1995, the Confederated Tribes of the Colville Reservation (Colville Confederated Tribes) have managed the Chief Joseph Kokanee Enhancement Project as part of the Northwest Power Planning Council (NWPPC) Fish and Wildlife Program. Project objectives have focused on understanding natural production of kokanee (a land-locked sockeye salmon) and other fish stocks in the area above Grand Coulee and Chief Joseph Dams on the Columbia River. A 42-month investigation from 1996 to 1999 determined that from 211,685 to 576,676 fish were entrained annually at Grand Coulee Dam. Analysis of the entrainment data found that 85% of the total entrainment occurred atmore » the dam's third powerplant. These numbers represent a significant loss to the tribal fisheries upstream of the dam. In response to a suggestion by the NWPPC Independent Scientific Review Panel, the scope of work for the Chief Joseph Kokanee Enhancement Project was expanded to include a multiyear pilot test of a strobe light system to help mitigate fish entrainment. This report details the work conducted during the third year of the strobe light study by researchers of the Colville Confederated Tribes in collaboration with the Pacific Northwest National Laboratory. The objective of the study is to determine the efficacy of a prototype strobe light system to elicit a negative phototactic response in kokanee and rainbow trout under field conditions. The prototype system consists of six strobe lights affixed to an aluminum frame suspended 15 m vertically underwater from a barge secured in the center of the entrance to the third powerplant forebay. The lights, controlled by a computer, illuminate a region directly upstream of the barge. The 2003 study period extended from June 16 through August 1. Three light treatments were used: all six lights on for 24 hours, all lights off for 24 hours, and three of six lights cycled on and off every hour for 24 hours. These three treatment conditions were assigned randomly within a 3-day block throughout the study period. Hydroacoustic technology was used to evaluate the effectiveness of the strobe lights in eliciting a negative phototactic response in fish. The hydroacoustic system in 2003 comprised seven splitbeam transducers arrayed in front of the strobe lights, two multibeam transducers behind the lights, and a mobile splitbeam system. The seven splitbeam transducers were deployed so they tracked fish entering and within the region illuminated by the strobe lights. These transducers were spaced approximately 4 m apart on an aluminum frame floating upstream of the barge and looked vertically downward. The multibeam transducers monitored the distribution of fish directly behind and to both sides of the lights, while the mobile splitbeam system looked at the distribution of fish within the third powerplant forebay. To augment the hydroacoustic data, additional studies were conducted. The hydrodynamic characteristics of the third powerplant forebay were measured, and acoustically tagged juvenile kokanee were released upstream of the strobe lights and tracked within the forebay and downstream of the dam. Analysis of the effect of strobe lights on kokanee and rainbow trout focused on the number of fish detected in each of the areas covered by one of the downlooking transducers, the timing of fish arrivals after the status of the strobe lights changed, fish swimming effort (detected velocity minus flow velocity), and fish swimming direction. Water velocity measurements were used to determine fish swimming effort. The tracking of tagged kokanee provided data on fish movements into and out of the third powerplant forebay, including entrainment.« less
Measurement of aircraft xenon strobe light characteristics
DOT National Transportation Integrated Search
1976-08-01
This report provides data on the characteristics of aircraft xenon strobe lights related to their potential for use as the cooperative element in Optical IR (Infrared) Airborne Proximity Warning Indicator (APWI) systems. It includes a description of ...
Avoidance of strobe lights by zooplankton
Hamel, Martin J.; Richards, Nathan S.; Brown, Michael L.; Chipps, Steven R.
2010-01-01
Underwater strobe lights can influence the behavior and distribution of fishes and are increasingly used as a technique to divert fish away from water intake structures on dams. However, few studies examine how strobe lights may affect organisms other than targeted species. To gain insight on strobe lighting effects on nontarget invertebrates, we investigated whether underwater strobe lights influence zooplankton distributions and abundance in Lake Oahe, South Dakota. Zooplankton were collected using vertical tows at 3 discrete distances from an underwater strobe light to quantify the influence of light intensity on zooplankton density. Samples were collected from 3 different depth ranges (0–10 m, 10–20 m and 20–30 m) at <1 m, 15 m and ⩾100 m distance intervals away from the strobe light. Copepods represented 67.2% and Daphnia spp. represented 23.3% of all zooplankton sampled from 17 August to 15 September 2004. Night time zooplankton densities significantly decreased in surface waters when strobe lights were activated. Copepods exhibited the greatest avoidance patterns, while Daphnia avoidance varied throughout sampling depths. These results indicate that zooplankton display negative phototaxic behavior to strobe lights and that researchers must be cognizant of potential effects to the ecosystem such as altering predator–prey interactions or affecting zooplankton distribution and growth.
77 FR 54848 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... damage to the operation of other critical airplane systems due to electromagnetic coupling and large... strike to the tail strobe light, electromagnetic coupling and large transient voltages can be transmitted... electromagnetic coupling, since the tail strobe light is located in a flammable leakage zone, electrical current...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, Russlee; Farley, M.; Hansen, Gabriel
In 1995, the Chief Joseph Kokanee Enhancement Project was established to mitigate the loss of anadromous fish due to the construction of Chief Joseph and Grand Coulee dams. The objectives of the Chief Joseph Enhancement Project are to determine the status of resident kokanee (Oncorhynchus nerka) populations above Chief Joseph and Grand Coulee dams and to enhance kokanee and rainbow trout (Oncorhynchus mykiss) populations. Studies conducted at Grand Coulee Dam documented substantial entrainment of kokanee through turbines at the third powerhouse. In response to finding high entrainment at Grand Coulee Dam, the Independent Scientific Review Panel (ISRP) recommended investigating themore » use of strobe lights to repel fish from the forebay of the third powerhouse. Therefore, our study focused on the third powerhouse and how strobe lights affected fish behavior in this area. The primary objective of our study was to assess the behavioral response of kokanee and rainbow trout to strobe lights using 3D acoustic telemetry, which yields explicit spatial locations of fish in three dimensions. Our secondary objectives were to (1) use a 3D acoustic system to mobile track tagged fish in the forebay and upriver of Grand Coulee Dam and (2) determine the feasibility of detecting fish using a hydrophone mounted in the tailrace of the third powerhouse. Within the fixed hydrophone array located in the third powerhouse cul-de-sac, we detected 50 kokanee and 30 rainbow trout, accounting for 47% and 45% respectively, of the fish released. Kokanee had a median residence time of 0.20 h and rainbow trout had a median residence time of 1.07 h. We detected more kokanee in the array at night compared to the day, and we detected more rainbow trout during the day compared to the night. In general, kokanee and rainbow trout approached along the eastern shore and the relative frequency of kokanee and rainbow trout detections was highest along the eastern shoreline of the 3D array. However, because we released fish near the eastern shore, this approach pattern may have resulted from our release location. A high percentage of rainbow trout (60%) approached within 35 m of the eastern shore, while fewer kokanee (40%) approached within 35 m of the eastern shore and were more evenly distributed across the entrance to the third powerhouse cul-de-sac area. During each of the strobe light treatments there were very few fish detected within 25 m of the strobe lights. The spatial distribution of fish detections showed relatively few tagged fish swam through the center of the array where the strobe lights were located. We detected 11 kokanee and 12 rainbow trout within 25 m of the strobe lights, accounting for 10% and 18% respectively, of the fish released. Both species exhibited very short residence times within 25 m of the strobe lights No attraction or repulsion behavior was observed within 25 m of the strobe lights. Directional vectors of both kokanee and rainbow trout indicate that both species passed the strobe lights by moving in a downstream direction and slightly towards the third powerhouse. We statistically analyzed fish behavior during treatments using a randomization to compare the mean distance fish were detected from the strobe lights. We compared treatments separately for day and night and with the data constrained to three distances from the strobe light (< 85m, < 50 m, and < 25 m). For kokanee, the only significant randomization test (of 10 tests) occurred with kokanee during the day for the 3-On treatment constrained to within 85 m of the strobe lights, where kokanee were significantly further away from the strobe lights than during the Off treatment (randomization test, P < 0.004, Table 1.5). However, one other test had a low P-value (P = 0.064) where kokanee were closer to the lights during the 3-On treatment at night within 85 m of the strobe lights compared to the Off treatment. For rainbow trout, none of the 11 tests were significant, but one test had a low P-value (P = 0.04), and fish were further away from the strobe lights during the 6-On treatment, within 50 m, during the day (Table 1.5). During 2002, it is unclear whether tagged fish truly had little response to the strobe lights, or whether too few fish near the strobe lights and short residence times prevented us from detecting a behavioral response to the strobe lights. Although fish tended to be slightly further away from the strobe lights during 3-On and 6-On treatments compared to the Off treatment, only one of the 21 statistical tests indicated that these differences were significant. However, within 25 m of the strobe lights we may have had little power to detect a difference due to the few fish available for statistical comparison. We detected 32 kokanee and 7 rainbow trout in the tailrace of Grand Coulee Dam, accounting for 30% and 12%, respectively of the fish released.« less
A synchronous strobed laser light sheet for helicopter model rotor flow visualization
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.; Rhodes, David B.; Jones, Stephen B.; Franke, John M.
1990-01-01
A synchronous, strobed laser light sheet has been developed for use in flow visualization of a helicopter rotor model. The light sheet strobe circuit included selectable blade position, strobe duration, and multiple pulses per revolution for rotors having 2 to 9 blades. The flow was seeded with propylene glycol. Between runs, a calibration grid board was placed in the plane of the laser sheet and recorded with the video camera at the position used to record the flow field. A slip-sync mode permitted slow motion visualization of the flow field over complete rotations of the rotor. The system was used to make two-dimensional flow field cuts of a four-bladed rotor operating at advance ratio of 0.37 at wind tunnel speeds up to 79.25 meters per second (260 feet per second).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R.; McKinstry, C.; Simmons, C.
Since 1995, the Confederated Tribes of the Colville Reservation (Colville Confederated Tribes) have managed the Chief Joseph Kokanee Enhancement Project as part of the Northwest Power Planning Council (NWPPC) Fish and Wildlife Program. Project objectives have focused on understanding natural production of kokanee (a land-locked sockeye salmon) and other fish stocks in the area above Grand Coulee and Chief Joseph Dams on the Columbia River. A 42-month investigation concluded that entrainment at Grand Coulee Dam ranged from 211,685 to 576,676 fish annually. Further analysis revealed that 85% of the total entrainment occurred at the dam's third powerplant. These numbers representmore » a significant loss to the tribal fisheries upstream of the dam. In response to a suggestion by the NWPPC Independent Scientific Review Panel, the scope of work for the Chief Joseph Kokanee Enhancement Project was expanded to include a multiyear pilot test of a strobe light system to help mitigate fish entrainment. This report details the work conducted during the second year of the study by researchers of the Colville Confederated Tribes in collaboration with the Pacific Northwest National Laboratory. The 2002 study period extended from May 18 through July 30. The objective of the study was to determine the efficacy of a prototype strobe light system to elicit a negative phototactic response in kokanee and rainbow trout. The prototype system consisted of six strobe lights affixed to an aluminum frame suspended vertically underwater from a barge secured in the center of the entrance to the third powerplant forebay. The lights, controlled by a computer, were aimed to illuminate a specific region directly upstream of the barge. Three light level treatments were used: 6 of 6 lights on, 3 of 6 lights on, and all lights off. These three treatment conditions were applied for an entire 24-hr day and were randomly assigned within a 3-day block throughout the study period. A seven-transducer splitbeam hydroacoustic system was used to evaluate the effectiveness of the strobe lights in eliciting a negative phototactic response in fish. The transducers were deployed so they tracked fish entering and within the region illuminated by the strobe lights. Two of the seven transducers were mounted to the frame containing the strobe lights and were oriented horizontally. The remaining five transducers were spaced approximately 4 m apart on individual floating frames upstream of the barge, with the transducers looking vertically downward.« less
Period and pulse duration with "strobe" lights
NASA Astrophysics Data System (ADS)
Birriel, Jennifer
2016-01-01
Strobe lights have traditionally been discussed in The Physics Teacher in the context of stop action strobe photography. During the Halloween season most department and hardware stores sell inexpensive, compact "strobe" lights (although these can be found online year round). These lights generally sell for under 10 and usually employ LED lights. Most such devices have a rotary switch to adjust the rate at which the LED bulbs flash. This rotary switch is not calibrated—i.e., it has no markings to indicate the rate, but in general the greater the rotation of the switch from the off position, the faster the rate of flashing. We show how these simple devices can be used with a light sensor to study both the frequency of flashing and the duration of the light pulse. We briefly discuss if these devices are truly strobe lights.
DOT National Transportation Integrated Search
1994-11-01
The objective of this study was to evaluate the effectiveness of using strobe lights in the red lens of traffic signals and, if appropriate, to recommend guidelines for their use. Strobe lights are used as a supplement to the red lens to draw the att...
Kock, Tobias J.; Evans, Scott D.; Liedtke, Theresa L.; Rondorf, Dennis W.; Kohn, Mike
2009-01-01
We conducted a radiotelemetry evaluation to determine if strobe lights could be used to decrease turbine entrainment of juvenile steelhead (Oncorhynchus mykiss) at Cowlitz Falls Dam, Washington. We found that radio-tagged juvenile steelhead approached and entered two spillbays (one lighted, one unlighted) in equal proportions. However, the presence of strobe lights was associated with decreased spillbay residence time of juvenile steelhead and increased passage through induction slots (secondary turbine intakes located upstream of the ogee on the spillway). Mean residence time of tagged fish inside the lighted spillbay was 14 min compared to 62 min inside the unlighted spillbay. Radio-tagged steelhead passed through induction slots at a higher proportion in the lighted spillbay (55%) than in the unlighted spillbay (26%). Recent studies have suggested that strobe lights can induce torpor in juvenile salmonids. We believe that strobe light exposure affected fish in our study at a location where they were susceptible to high flows thereby reducing mean residence time and increasing the proportion of tagged fish entering induction slots in the lighted spillbay. Our results suggest that factors such as deployment location, exposure, and flow are important variables that should be considered when evaluating strobe lights as a potential fish-deterring management tool.
Pc-based car license plate reading
NASA Astrophysics Data System (ADS)
Tanabe, Katsuyoshi; Marubayashi, Eisaku; Kawashima, Harumi; Nakanishi, Tadashi; Shio, Akio
1994-03-01
A PC-based car license plate recognition system has been developed. The system recognizes Chinese characters and Japanese phonetic hiragana characters as well as six digits on Japanese license plates. The system consists of a CCD camera, vehicle sensors, a strobe unit, a monitoring center, and an i486-based PC. The PC includes in its extension slots: a vehicle detector board, a strobe emitter board, and an image grabber board. When a passing vehicle is detected by the vehicle sensors, the strobe emits a pulse of light. The light pulse is synchronized with the time the vehicle image is frozen on an image grabber board. The recognition process is composed of three steps: image thresholding, character region extraction, and matching-based character recognition. The recognition software can handle obscured characters. Experimental results for hundreds of outdoor images showed high recognition performance within relatively short performance times. The results confirmed that the system is applicable to a wide variety of applications such as automatic vehicle identification and travel time measurement.
Laboratory evaluation of Fecker and Loral optical IR PWI systems
NASA Technical Reports Server (NTRS)
Gorstein, M.; Hallock, J. N.; Houten, M.; Mcwilliams, I. G.
1971-01-01
A previous flight test of two electro-optical pilot warning indicators, using a flashing xenon strobe and silicon detectors as cooperative elements, pointed out several design deficiencies. The present laboratory evaluation program corrected these faults and calibrated the sensitivity of both systems in azimuth elevation and range. The laboratory tests were performed on an optical bench and consisted of three basic components: (1) a xenon strobe lamp whose output is monitored at the indicator detector to give pulse to pulse information on energy content at the receiver; (2) a strobe light attenuating optical system which is calibrated photometrically to provide simulated range; and (3) a positioning table on which the indicator system under study is mounted and which provides spatial location coordinates for all data points. The test results for both systems are tabulated.
Operational Testing of Locomotive-Mounted Strobe Lights
DOT National Transportation Integrated Search
1980-06-01
The report describes revenue-service tests of locomotive-mounted strobe lights used to make trains more conspicuous to motorists at rail-highway crossings. The testing, conducted in cooperation with four railroads, had the objectives of assuring prac...
Bruck, Dorothy; Thomas, Ian R
2009-02-01
People who are hard-of-hearing may rely on auditory, visual, or tactile alarms in a fire emergency, and US standards require strobe lights in hotel bedrooms to provide emergency notification for people with hearing loss. This is the first study to compare the waking effectiveness of a variety of auditory (beeps), tactile (bed and pillow shakers), and visual (strobe lights) signals at a range of intensities. Three auditory signals, a bed shaker, a pillow shaker, and strobe lights were presented to 38 adults (aged 18 to 80 yr) with mild to moderately severe hearing loss of 25 to 70 dB (in both ears), during slow-wave sleep (deep sleep). Two of the auditory signals were selected on the basis that they had the lowest auditory thresholds when awake (from a range of eight signals). The third auditory signal was the current 3100-Hz smoke alarm. All auditory signals were tested below, at, and above the decibel level prescribed by the applicable standard for bedrooms (75 dBA). In the case of bed and pillow shakers intensities below, at, and above the level as purchased were tested. For strobe lights three levels were used, all of which were above the applicable standard. The intensity level at which participants awoke was identified by electroencephalograph monitoring. The most effective signal was a 520-Hz square wave auditory signal, waking 92% at 75 dBA, compared with 56% waking to the 75 dBA high-pitched alarm. Bed and pillow shakers awoke 80 to 84% at the intensity level as purchased. The strobe lights awoke only 27% at an intensity above the US standard. Nonparametric analyses confirmed that the 520-Hz square wave signal was significantly more effective than the current smoke alarm and the strobe lights in waking this population. A low-frequency square wave signal has now been found to be significantly more effective than all tested alternatives in a number of populations (hard-of-hearing, children, older adults, young adults, alcohol impaired) and should be adopted across the whole population as the normal smoke alarm signal. Strobe lights, even at high intensities, are ineffective in reliably waking people with mild to moderate hearing loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, Robert P.; Neitzel, Duane A.; Amidan, Brett G.
2001-12-01
Laboratory tests were conducted using juvenile chinook salmon Oncorhynchus tshawytscha, brook trout Salvelinus fontinalis, and rainbow trout O. mykiss to determine specific behavior responses to infrasound (< 20 Hz) and flashing strobe lights. The objective of these tests was to determine if juvenile salmonids could be deterred from entrainment at water diversion structures. Caged fish were acclimated in a static test tank and their behavior was recorded using low light cameras. Species-specific behavior was characterized by measuring movements of the fish within the cage and by observing startle and habituation responses. Wild chinook salmon (40-45 mm TL) and hatchery rearedmore » chinook salmon (45-50 mm TL) exhibited avoidance responses when initially exposed to a 10-Hz volume displacement source of infrasound. Rainbow and eastern brook trout (25-100 mm TL) did not respond with avoidance or other behaviors to infrasound. Evidence of habituation to the infrasound source was evident for chinook salmon during repeated exposures. Wild and hatchery chinook displayed a higher proportion of movement during the initial exposures to infrasound when the acclimation period in the test tank was 2-3 h as compared to a 12-15 h acclimation period. A flashing strobe light produced consistent movement in wild chinook salmon (60% of the tests), hatchery reared chinook salmon (50%), and rainbow trout (80%). No measurable responses were observed for brook trout. Results indicate that consistent, repeatable responses can be elicited from some fish using high-intensity strobe lights under a controlled laboratory testing. The species specific behaviors observed in these experiments might be used to predict how fish might react to low-frequency sound and strobe lights in a screening facility.« less
Multi-Head Very High Power Strobe System For Motion Picture Special Effects
NASA Astrophysics Data System (ADS)
Lovoi, P. A.; Fink, Michael L.
1983-10-01
A very large camera synchronizable strobe system has been developed for motion picture special effects. This system, the largest ever built, was delivered to MGM/UA to be used in the movie "War Games". The system consists of 12 individual strobe heads and a power supply distribution system. Each strobe head operates independently and may be flashed up to 24 times per second under computer control. An energy of 480 Joules per flash is used in six strobe heads and 240 Joules per flash in the remaining six strobe heads. The beam pattern is rectangular with a FWHM of 60° x 48°.
Effects of a fire alarm strobe light on fecal corticosterone metabolite concentrations in mice.
Godfrey, Denice; Silverman, Jerald
2009-02-01
The type and location of fire alarms are important considerations in animal facility design. The Guide for the Care and Use of Laboratory Animals recommends minimizing animal exposure to such alarms. Nevertheless, it is often necessary to maintain fire alarms within animal housing or procedural areas. The authors exposed male mice to the flashing strobe light component of a standard fire alarm and evaluated mouse fecal corticosterone concentration, which is known to be an indicator of stress. Mice were exposed to the strobe light for 5 min during either the light or the dark phase of the light:dark cycle. The authors collected fecal samples every 6 h for 24 h before exposing mice to the alarm and every 6 h for 24 h after exposure. Fecal samples taken before exposure (baseline samples) showed a normal circadian pattern of corticosterone metabolite excretion. In fecal samples taken after mice were exposed to the fire alarm, metabolite concentrations did not significantly differ from baseline concentrations over time.
New Directions in X-Ray Light Sources
Falcone, Roger
2017-12-09
July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, M.; Johnson, Robert; McKinstry, C.
The construction of Grand Coulee and Chief Joseph dams on the Columbia River resulted in the complete extirpation of the anadromous fishery upstream of these structures. Today, this area is totally dependent upon resident fish resources to support local fisheries. The resident fishing is enhanced by an extensive stocking program for target species in the existing fishery, including kokanee (Oncorhynchus nerka kennerlyi) and rainbow trout (O. mykiss). The kokanee fishery in Lake Roosevelt has not been meeting the return goals set by fisheries managers despite the stocking program. Investigations of physical and biological factors that could affect the kokanee populationmore » found predation and entrainment had a significant impact on the fish population. In 1999 and 2000, walleye (Sander vitreum) consumed between 15% and 9%, respectively, of the hatchery kokanee within 41 days of their release, while results from a study in the late 1990s estimated that entrainment at Grand Coulee Dam could account for up to 30% of the total mortality of the stocked fish. To address the entrainment loss, the Bonneville Power Administration commissioned a study to determine if fish would avoid areas illuminated by strobe lights in the forebay of the third powerplant. This work was conducted by Pacific Northwest National Laboratory (PNNL) in conjunction with the Confederated Tribes of the Colville Reservation (Colville Confederated Tribes). From 2002 through 2004, six strobe lights were suspended in the center of the opening to the third powerplant forebay during summer months. Results from those studies indicated that fish appeared to be attracted to the illuminated area but only at night and when flow conditions within the third powerplant forebay were minimal. However, small but consistent results from these studies indicated that under high flow conditions, fish might be avoiding the lights. The 2005 study was designed to examine whether, under high flow conditions near the penstock openings, fish would avoid the lighted regions. Four omnidirectional strobe lights were deployed on the one trash rack directly in front of one turbine penstock. Seven splitbeam transducers were deployed to monitor fish approaching three penstock openings either from in front of the trash racks or moving down the dam behind the trash racks. Four key results emerged from the 2005 study. The results provide insight into the current level of entrainment and how fish respond to strobe lights under high flow conditions. First, very few fish were detected inside the trash racks. Of the more than 3,200 targets identified by the data processing, less than 100 were detected inside the trash racks. Only 23 fish were found inside the trash racks behind the strobe lights. Of those 21 fish, 13 were detected when the lights were on. Most of the fish detected behind the trash racks were above the turbine penstock but were headed downward. No fish were detected at night when minimal flows occurred between midnight and 4:00 a.m. Second, significantly more fish (P < 0.001) were detected in front of the trash racks when the lights were on at night. On a count-per-hour basis, the difference between lights off and lights on was apparent in the early morning hours at depths between 25 m and 50 m from the transducers. The lights were approximately 34 m below the splitbeam transducers, and fish detected at night with lights on were found at a median depth of approximately 35 m, compared to a median depth of from 20.6 to 23.5 m when the lights were off. The differences in depth between lights on and off at night were also significant (P < 0.001). Additionally, the increase in fish occurred only in front of the trash rack where the strobe lights were mounted; there was no increase in the number of detections by the transducers aimed away from the lights. Third, fish clearly manifested a behavioral response to the strobe lights during the day. When the lights were on, fish detected by three of the four transducers generally were swimming north, parallel to the face of the dam. However, the distribution of swimming directions for fish detected by the transducer immediately to the north of the lights was bimodal, with some fish swimming south toward the lighted region. This behavior was similar to that seen at night when the lights were on. Fourth, kokanee, rainbow trout, and walleye were detected near the strobe lights. Data were obtained from three sources: fish size from the hydroacoustic sensors and fish species from gill netting and video recording. Fish ranging in length from 30 to 600 mm (averaging 125 mm) were detected by the splitbeam transducers. There was little difference in target strength for fish detected above 25 m depth with respect to time of day or light treatment. Below 25 m and closer to the strobe lights, larger fish were present when the lights were on during the night, and smaller fish were present during the day.« less
Auditory-visual stimulus pairing enhances perceptual learning in a songbird.
Hultsch; Schleuss; Todt
1999-07-01
In many oscine birds, song learning is affected by social variables, for example the behaviour of a tutor. This implies that both auditory and visual perceptual systems should be involved in the acquisition process. To examine whether and how particular visual stimuli can affect song acquisition, we tested the impact of a tutoring design in which the presentation of auditory stimuli (i.e. species-specific master songs) was paired with a well-defined nonauditory stimulus (i.e. stroboscope light flashes: Strobe regime). The subjects were male hand-reared nightingales, Luscinia megarhynchos. For controls, males were exposed to tutoring without a light stimulus (Control regime). The males' singing recorded 9 months later showed that the Strobe regime had enhanced the acquisition of song patterns. During this treatment birds had acquired more songs than during the Control regime; the observed increase in repertoire size was from 20 to 30% in most cases. Furthermore, the copy quality of imitations acquired during the Strobe regime was better than that of imitations developed from the Control regime, and this was due to a significant increase in the number of 'perfect' song copies. We conclude that these effects were mediated by an intrinsic component (e.g. attention or arousal) which specifically responded to the Strobe regime. Our findings also show that mechanisms of song learning are well prepared to process information from cross-modal perception. Thus, more detailed enquiries into stimulus complexes that are usually referred to as social variables are promising. Copyright 1999 The Association for the Study of Animal Behaviour.
Visual and Kinesthetic Components of Pursuit-Tracking Performance.
ERIC Educational Resources Information Center
Thorsheim, Howard I.; And Others
Seventy-five subjects were trained on a pursuit rotor for 10 trials, with ambient illumination from a strobe light flashing at frequencies of either 2,5,10,15, or 20 per second. A transfer trial followed, with a strobe flashing frequency of 10 per second for all subjects. Results supported hypotheses derived from Adams' closed-loop theory of motor…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, M.A.; McKinstry, C.A.; Simmons, C.S.
Since 1995, the Colville Confederated Tribes have managed the Chief Joseph Kokanee Enhancement Project as part of the Northwest Power Planning Council's (NWPPC) Fish and Wildlife Program. Project objectives have focused on understanding natural production of kokanee (a land-locked sockeye salmon) and other fish stocks in the area above Grand Coulee and Chief Joseph Dams on the Columbia River. A 42-month investigation concluded that entrainment at Grand Coulee Dam ranged from 211,685 to 576,676 fish annually. Further analysis revealed that 85% of the total entrainment occurred at the dam's third powerplant. These numbers represent a significant loss to the tribalmore » fisheries upstream of the dam. In response to a suggestion by the NWPPC's Independent Scientific Review Panel, the scope of work for the Chief Joseph Kokanee Enhancement Project was expanded to include a multiyear pilot test of a strobe light system to help mitigate fish entrainment. This report details the work conducted during the first year of the study by researchers of the Colville Confederated Tribes in collaboration with the Pacific Northwest National Laboratory (PNNL). The objective of the study was to determine the efficacy of a prototype strobe light system to elicit a negative phototactic response in kokanee and rainbow trout. Analysis of the effect of strobe lights on the distribution (numbers) and behavior of kokanee and rainbow trout was based on 51, 683 fish targets detected during the study period (June 30 through August 1, 2001). Study findings include the following: (1) Analysis of the count data indicated that significantly more fish were present when the lights were on compared to off. This was true for both the 24-hr tests as well as the 1-hr tests. Powerplant discharge, distance from lights, and date were significant factors in the analysis. (2) Behavioral results indicated that fish within 14 m of the lights were trying to avoid the lights by swimming across the lighted region or upstream. Fish were also swimming faster and straighter when the lights were on compared to off. (3) The behavioral results were most pronounced for medium- and large-sized fish at night. Medium-sized fish, based on acoustic target strength, were similar to the size of kokanee and rainbow trout released upstream of Grand Coulee Dam. Based on this study and general review of strobe lights, the researchers recommend several modifications and enhancements to the follow-on study in 2002. The recommendations include: (1) modifying the study design to include only the 24-hr on/off treatments, and controlling the discharge at the third powerplant, so it can be included as a design variable; and (2) providing additional data by beginning the study earlier (mid-May) to better capture the kokanee population, deploying an additional splitbeam transducer to sample the region close to the lights, and increasing the number of lights to provide better definition of the lit and unlit region.« less
Falcone, Roger [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Univ. of California, Berkeley, CA (United States). Dept. of Physics
2018-05-04
Summer Lecture Series 2008: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.
Chen, Brian R; Poon, Emily; Alam, Murad
2018-01-01
Lighting is an important component of consistent, high-quality dermatologic photography. There are different types of lighting solutions available. To evaluate currently available lighting equipment and methods suitable for procedural dermatology. Overhead lighting, built-in camera flashes, external flash units, studio strobes, and light-emitting diode (LED) light panels were evaluated with regard to their utility for dermatologic surgeons. A set of ideal lighting characteristics was used to examine the capabilities and limitations of each type of lighting solution. Recommendations regarding lighting solutions and optimal usage configurations were made in terms of the context of the clinical environment and the purpose of the image. Overhead lighting may be a convenient option for general documentation. An on-camera lighting solution using a built-in camera flash or a camera-mounted external flash unit provides portability and consistent lighting with minimal training. An off-camera lighting solution with studio strobes, external flash units, or LED light panels provides versatility and even lighting with minimal shadows and glare. The selection of an optimal lighting solution is contingent on practical considerations and the purpose of the image.
NASA Technical Reports Server (NTRS)
Anderson, T. O. (Inventor)
1976-01-01
An interface logic circuit permitting the transfer of information between two computers having asynchronous clocks is disclosed. The information transfer involves utilization of control signals (including request, return-response, ready) to generate properly timed data strobe signals. Noise problems are avoided because each control signal, upon receipt, is verified by at least two clock pulses at the receiving computer. If control signals are verified, a data strobe pulse is generated to accomplish a data transfer. Once initiated, the data strobe signal is properly completed independently of signal disturbances in the control signal initiating the data strobe signal. Completion of the data strobe signal is announced by automatic turn-off of a return-response control signal.
McEwan, T.E.
1995-11-28
A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing. 17 figs.
McEwan, Thomas E.
1995-01-01
A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing.
Field Evaluation of Locomotive Conspicuity Lights
DOT National Transportation Integrated Search
1975-05-01
Flashing xenon strobe lamps were installed on locomotives in revenue service as a means of alerting motorists to the hazards they are approaching at a rail-highway grade crossing. Effectiveness of these lights in attracting motorists' attention was e...
Centering a DDR Strobe in the Middle of a Data Packet
NASA Technical Reports Server (NTRS)
Johnson, Michael; Nelson, Dave; Seefeldt, James; Roper, Weston; Passow, Craig
2014-01-01
The Orion CEV Northstar ASIC (application- specific integrated circuit) project required a DDR (double data rate) memory bus driver/receiver (DDR PHY block) to interface with external DDR memory. The DDR interface (JESD79C) is based on a source synchronous strobe (DQS\\) that is sent along with each packet of data (DQ). New data is provided concurrently with each edge of strobe and is sent irregularly. In order to capture this data, the strobe needs to be delayed and used to latch the data into a register. A circuit solves the need for training a DDR PRY block by incorporating a PVT-compensated delay element in the strobe path. This circuit takes an external reference clock signal and uses the regular clock to calibrate a known delay through a data path. The compensated delay DQS signal is then used to capture the DQ data in a normal register. This register structure can be configured as a FIFO (first in first out), in order to transfer data from the DDR domain to the system clock domain. This design is different in that it does not rely upon the need for training the system response, nor does it use a PLL (phase locked loop) or a DLL (delay locked loop) to provide an offset of the strobe signal. The circuit is created using standard ASIC building blocks, plus the PVT (process, voltage, and temperature) compensated delay line. The design uses a globally available system clock as a reference, alleviating the need to operate synchronously with the remote memory. The reference clock conditions the PVT compensated delay line to provide a pre-determined amount of delay to any data signal that passes through this delay line. The delay line is programmed in degrees of offset, so that one could think of the clock period representing 360deg of delay. In an ideal environment, delaying the strobe 1/4 of a clock cycle (90deg) would place the strobe in the middle of the data packet. This delayed strobe can then be used to clock the data into a register, satisfying setup and hold requirements of the system.
2014-07-14
Air Force Environmental conditions simulation equipment Equipment that simulates conditions such as waves, wind, rain, thunder , lightning , and...Environmental conditions simulation equipment Equipment that simulates conditions such as waves, wind, rain, thunder , lightning , and combat sounds...items such as wave generators, heavy-duty fans to simulate high winds, strobe lights to simulate lightning , water spray and injection systems to
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R.; McKinstry, C.; Cook, C.
This report documents a four-year study(a) to assess the efficacy of a prototype strobe light system to elicit a negative phototactic response in kokanee (Oncorhynchus nerka kennerlyi) and rainbow trout (O. mykiss) at the entrance to the forebay of the third powerplant at Grand Coulee Dam. The work was conducted for the Bonneville Power Administration, U.S. Department of Energy, by Pacific Northwest National Laboratory (PNNL) in conjunction with the Confederated Tribes of the Colville Reservation (Colville Confederated Tribes). In this report, emphasis is placed on the methodology and results associated with the fourth project year and compared with findings frommore » the previous years to provide an overall project summary. Since 1995, the Colville Confederated Tribes have managed the Chief Joseph Kokanee Enhancement Project as part of the Northwest Power and Conservation Council Fish and Wildlife Program. Project objectives have focused on understanding natural production of kokanee (a land-locked sockeye salmon) and other fish stocks in the area above Grand Coulee and Chief Joseph dams on the Columbia River (Figure S.1). A 42-month investigation from 1996 to 1999 determined that from 211,685 to 576,676 fish, including kokanee and rainbow trout, were entrained annually at Grand Coulee Dam. Analysis of the data found that 85% of the total entrainment occurred at the dam's third powerplant. Because these entrainment rates represent a significant loss to the tribal fisheries upstream of the dam, they have been judged unacceptable to fishery managers responsible for perpetuating the fishery in Lake Roosevelt. In an effort to reduce fish entrainment rates, the scope of work for the Chief Joseph Kokanee Enhancement Project was modified in 2001 to include a multiyear study of the efficacy of using strobe lights to deter fish from entering the third powerplant forebay. Pacific Northwest National Laboratory initiated the four-year study in collaboration with Colville Tribal Fisheries. The objective of the study was to determine the efficacy of a prototype strobe light system to elicit a negative phototactic response in kokanee and rainbow trout under field conditions.« less
Lights and siren: a review of emergency vehicle warning systems.
De Lorenzo, R A; Eilers, M A
1991-12-01
Emergency medical services providers routinely respond to emergencies using lights and siren. This practice is not without risk of collision. Audible and visual warning devices and vehicle markings are integral to efficient negotiation of traffic and reduction of collision risk. An understanding of warning system characteristics is necessary to implement appropriate guidelines for prehospital transportation systems. The pertinent literature on emergency vehicle warning systems is reviewed, with emphasis on potential health hazards associated with these techniques. Important findings inferred from the literature are 1) red flashing lights alone may not be as effective as other color combinations, 2) there are no data to support a seizure risk with strobe lights, 3) lime-yellow is probably superior to traditional emergency vehicle colors, 4) the siren is an extremely limited warning device, and 5) exposure to siren noise can cause hearing loss. Emergency physicians must ensure that emergency medical services transportation systems consider the pertinent literature on emergency vehicle warning systems.
The STROBE statement and neuropsychology: lighting the way toward evidence-based practice.
Loring, David W; Bowden, Stephen C
2014-01-01
Reporting appropriate research detail across clinical disciplines is often inconsistent or incomplete. Insufficient report detail reduces confidence in findings, makes study replication more difficult, and decreases the precision of data available for critical review including meta-analysis. In response to these concerns, cooperative attempts across multiple specialties have developed explicit research reporting standards to guide publication detail. These recommendations have been widely adopted by high impact medical journals, but have not yet been widely embraced by neuropsychology. The STROBE Statement (STrengthening the Reporting of Observational studies in Epidemiology) is particularly relevant to neuropsychology since clinical research is often based on non-funded studies of patient samples. In this paper we describe the STROBE Statement and demonstrate how STROBE criteria, applied to reporting of neuropsychological findings, will maintain neuropsychology's position as a leader in quantifying brain-behavior relationships. We also provide specific recommendations for data reporting and disclosure of perceived conflicts of interest that will further enhance reporting transparency for possible perceived sources of bias. In an era in which evidence-based practice assumes an increasingly prominent role, improved reporting standards will promote better patient care, assist in developing quality practice guidelines, and ensure that neuropsychology remains a vigorous discipline in the clinical neurosciences that consciously aspires to high methodological rigor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. We tested one set of nine strobe lights flashing at a rate of 360 flashes/min in front of turbine 3 while operating at higher discharges than previously tested. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On five nights between January 31 andmore » February 28, 2006, when no lights were present, fish counts near turbine 3 averaged eight fish and densities averaged 91 fish/ha. When strobe lights were turned on during five adjacent nights during the same period, mean counts dropped to four fish and densities dropped to 35 fish/ha. The decline in counts (49%) was not statistically significant (p = 0.182), but decline in densities (62%) was significant (p = 0.049). There appeared to be no tendency for fish to habituate to the lights during the night. Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of turbines operating at higher discharges, which would be sufficient to improve sportfish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2005. Estimated abundance of kokanee decreased from the 2004 population estimate. Based on hydroacoustic surveys, we estimated 3,011,626 kokanee (90% CI {+-} 15.2%) in Dworshak Reservoir, July 2005. This included 2,135,986 age-0 (90% CI {+-} 15.9%), 769,175 age-1 (90% CI {+-} 16.0%), and 107,465 age-2 (90% CI {+-} 15.2%). Poor survival of kokanee from age-1 to age-2 continued to keep age-2 densities below the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site split-beam hydroacoustics a minimum of two days per month for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were again found during nighttime periods and lowest during the day. Fish detection rates were low during high discharges throughout the spring and summer and highest during low discharges in September and November. High discharge during drawdowns for anadromous fish flows in July and August again resulted in low detection rates and susceptibility to entrainment. Index counts of spawning kokanee in four tributary streams totaled 12,742 fish. This data fits the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
Bastuji-Garin, Sylvie; Sbidian, Emilie; Gaudy-Marqueste, Caroline; Ferrat, Emilie; Roujeau, Jean-Claude; Richard, Marie-Aleth; Canoui-Poitrine, Florence
2013-01-01
In uncontrolled before-after studies, CONSORT was shown to improve the reporting of randomised trials. Before-after studies ignore underlying secular trends and may overestimate the impact of interventions. Our aim was to assess the impact of the 2007 STROBE statement publication on the quality of observational study reporting, using both uncontrolled before-after analyses and interrupted time series. For this quasi-experimental study, original articles reporting cohort, case-control, and cross-sectional studies published between 2004 and 2010 in the four dermatological journals having the highest 5-year impact factors (≥ 4) were selected. We compared the proportions of STROBE items (STROBE score) adequately reported in each article during three periods, two pre STROBE period (2004-2005 and 2006-2007) and one post STROBE period (2008-2010). Segmented regression analysis of interrupted time series was also performed. Of the 456 included articles, 187 (41%) reported cohort studies, 166 (36.4%) cross-sectional studies, and 103 (22.6%) case-control studies. The median STROBE score was 57% (range, 18%-98%). Before-after analysis evidenced significant STROBE score increases between the two pre-STROBE periods and between the earliest pre-STROBE period and the post-STROBE period (median score2004-05 48% versus median score2008-10 58%, p<0.001) but not between the immediate pre-STROBE period and the post-STROBE period (median score2006-07 58% versus median score2008-10 58%, p = 0.42). In the pre STROBE period, the six-monthly mean STROBE score increased significantly, by 1.19% per six-month period (absolute increase 95%CI, 0.26% to 2.11%, p = 0.016). By segmented analysis, no significant changes in STROBE score trends occurred (-0.40%; 95%CI, -2.20 to 1.41; p = 0.64) in the post STROBE statement publication. The quality of reports increased over time but was not affected by STROBE. Our findings raise concerns about the relevance of uncontrolled before-after analysis for estimating the impact of guidelines.
Bastuji-Garin, Sylvie; Sbidian, Emilie; Gaudy-Marqueste, Caroline; Ferrat, Emilie; Roujeau, Jean-Claude; Richard, Marie-Aleth; Canoui-Poitrine, Florence
2013-01-01
Background In uncontrolled before-after studies, CONSORT was shown to improve the reporting of randomised trials. Before-after studies ignore underlying secular trends and may overestimate the impact of interventions. Our aim was to assess the impact of the 2007 STROBE statement publication on the quality of observational study reporting, using both uncontrolled before-after analyses and interrupted time series. Methods For this quasi-experimental study, original articles reporting cohort, case-control, and cross-sectional studies published between 2004 and 2010 in the four dermatological journals having the highest 5-year impact factors (≥4) were selected. We compared the proportions of STROBE items (STROBE score) adequately reported in each article during three periods, two pre STROBE period (2004–2005 and 2006–2007) and one post STROBE period (2008–2010). Segmented regression analysis of interrupted time series was also performed. Results Of the 456 included articles, 187 (41%) reported cohort studies, 166 (36.4%) cross-sectional studies, and 103 (22.6%) case-control studies. The median STROBE score was 57% (range, 18%–98%). Before-after analysis evidenced significant STROBE score increases between the two pre-STROBE periods and between the earliest pre-STROBE period and the post-STROBE period (median score2004–05 48% versus median score2008–10 58%, p<0.001) but not between the immediate pre-STROBE period and the post-STROBE period (median score2006–07 58% versus median score2008–10 58%, p = 0.42). In the pre STROBE period, the six-monthly mean STROBE score increased significantly, by 1.19% per six-month period (absolute increase 95%CI, 0.26% to 2.11%, p = 0.016). By segmented analysis, no significant changes in STROBE score trends occurred (−0.40%; 95%CI, −2.20 to 1.41; p = 0.64) in the post STROBE statement publication. Interpretation The quality of reports increased over time but was not affected by STROBE. Our findings raise concerns about the relevance of uncontrolled before-after analysis for estimating the impact of guidelines. PMID:23990867
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stark, Eric J.
2008-12-18
During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less
High speed sampler and demultiplexer
McEwan, Thomas E.
1995-01-01
A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as "strobe kickout". The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition.
Two-flash thresholds as a function of flash luminance and area.
DOT National Transportation Integrated Search
1968-09-01
The recent use of strobe lights in aviation suggests the possibility of using temporal patterns of short duration flashes as information-carrying signals. Under night flight conditions, two-flash thresholds were obtained using a two-interval, tempora...
High speed sampler and demultiplexer
McEwan, T.E.
1995-12-26
A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as ``strobe kickout``. The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition. 16 figs.
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Perilli, Viviana; O'Reilly, Mark F.; Singh, Nirbhay N.; Sigafoos, Jeff; Bosco, Andrea; Caffo, Alessandro O.; Picucci, Luciana; Cassano, Germana; Groeneweg, Jop
2013-01-01
The present study (a) extended the assessment of an orientation program involving auditory cues (i.e., verbal messages automatically presented from the destinations) with five patients with Alzheimer's disease, (b) compared the effects of this program with those of a program with light cues (i.e., a program in which strobe lights were used instead…
DOT National Transportation Integrated Search
1971-11-01
The recent introduction of strobe lights for anticollision purposes raises the possibility of using temporal patterns of short duration flashes as information carrying signals. The current experiments are concerned with the detection of the minimum d...
Exposure of men to intermittent photic stimulation under simulated IFR conditions.
DOT National Transportation Integrated Search
1966-10-01
Ten men were subjected to intermittent photic stimulation in an airplane cockpit in an environmental chamber by (1) a Grimes red rotating beacon (1.5 FPS), (2) an Air Guard strobe light (1.0 FPS) and (3) propeller flicker (10 FPS). IFR conditions wer...
O'Connor, A M; Sargeant, J M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-12-01
The STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement was first published in 2007 and again in 2014. The purpose of the original STROBE was to provide guidance for authors, reviewers and editors to improve the comprehensiveness of reporting; however, STROBE has a unique focus on observational studies. Although much of the guidance provided by the original STROBE document is directly applicable, it was deemed useful to map those statements to veterinary concepts, provide veterinary examples and highlight unique aspects of reporting in veterinary observational studies. Here, we present the examples and explanations for the checklist items included in the STROBE-Vet Statement. Thus, this is a companion document to the STROBE-Vet Statement Methods and process document, which describes the checklist and how it was developed. © 2016 The Authors. Zoonoses and Public Health published by Blackwell Verlag GmbH.
O'Connor, A M; Sargeant, J M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-11-01
The STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement was first published in 2007 and again in 2014. The purpose of the original STROBE was to provide guidance for authors, reviewers, and editors to improve the comprehensiveness of reporting; however, STROBE has a unique focus on observational studies. Although much of the guidance provided by the original STROBE document is directly applicable, it was deemed useful to map those statements to veterinary concepts, provide veterinary examples, and highlight unique aspects of reporting in veterinary observational studies. Here, we present the examples and explanations for the checklist items included in the STROBE-Vet statement. Thus, this is a companion document to the STROBE-Vet statement methods and process document (JVIM_14575 "Methods and Processes of Developing the Strengthening the Reporting of Observational Studies in Epidemiology-Veterinary (STROBE-Vet) Statement" undergoing proofing), which describes the checklist and how it was developed. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Berg, Christina; Forsum, Elisabet; Larsson, Christel; Sonestedt, Emily; Åkesson, Agneta; Lachat, Carl; Hawwash, Dana; Kolsteren, Patrick; Byrnes, Graham; De Keyzer, Willem; Van Camp, John; Cade, Janet E; Greenwood, Darren C; Slimani, Nadia; Cevallos, Myriam; Egger, Matthias; Huybrechts, Inge; Wirfält, Elisabet
2017-01-01
Nutritional epidemiology is an inherently complex and multifaceted research area. Dietary intake is a complex exposure and is challenging to describe and assess, and links between diet, health, and disease are difficult to ascertain. Consequently, adequate reporting is necessary to facilitate comprehension, interpretation, and generalizability of results and conclusions. The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) statement is an international and collaborative initiative aiming to enhance the quality of reporting of observational studies. We previously presented a checklist of 24 reporting recommendations for the field of nutritional epidemiology, called “the STROBE-nut.” The STROBE-nut is an extension of the general STROBE statement, intended to complement the STROBE recommendations to improve and standardize the reporting in nutritional epidemiology. The aim of the present article is to explain the rationale for, and elaborate on, the STROBE-nut recommendations to enhance the clarity and to facilitate the understanding of the guidelines. Examples from the published literature are used as illustrations, and references are provided for further reading. PMID:28916567
2014-07-16
ISS040-E-067885 (16 July 2014) --- The Orbital Sciences’ Cygnus cargo craft attached to the end of the Canadarm2 robotic arm of the International Space Station is photographed by an Expedition 40 crew member after the two spacecraft converged at 6:36 a.m. (EDT) on July 16, 2014. The red color on Cygnus is a spectral effect from one of Cygnus’ strobe lights against the fading light heading into an orbital sunset following grapple.
Transient digitizer with displacement current samplers
McEwan, T.E.
1996-05-21
A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board. 16 figs.
Transient digitizer with displacement current samplers
McEwan, Thomas E.
1996-01-01
A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.
Ramke, Jacqueline; Palagyi, Anna; Jordan, Vanessa; Petkovic, Jennifer; Gilbert, Clare E
2017-01-01
Cross-sectional blindness prevalence surveys are essential to plan and monitor eye care services. Incomplete or inaccurate reporting can prevent effective translation of research findings. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement is a 32 item checklist developed to improve reporting of observational studies. The aim of this study was to assess the completeness of reporting in blindness prevalence surveys in low and middle income countries (LMICs) using STROBE. MEDLINE, EMBASE and Web of Science databases were searched on April 8 2016 to identify cross-sectional blindness prevalence surveys undertaken in LMICs and published after STROBE was published in December 2007. The STROBE tool was applied to all included studies, and each STROBE item was categorized as 'yes' (met criteria), 'no' (did not meet criteria) or 'not applicable'. The 'Completeness of reporting (COR) score' for each manuscript was calculated: COR score = yes / [yes + no]. In journals with included studies the instructions to authors and reviewers were checked for reference to STROBE. The 89 included studies were undertaken in 32 countries and published in 37 journals. The mean COR score was 60.9% (95% confidence interval [CI] 58.1-63.7%; range 30.8-88.9%). The mean COR score did not differ between surveys published in journals with author instructions referring to STROBE (10/37 journals; 61.1%, 95%CI 56.4-65.8%) or in journals where STROBE was not mentioned (60.9%, 95%CI 57.4-64.3%; p = 0.93). While reporting in blindness prevalence surveys is strong in some areas, others need improvement. We recommend that more journals adopt the STROBE checklist and ensure it is used by authors and reviewers.
Cone penetrometer fiber optic raman spectroscopy probe assembly
Kyle, Kevin R.; Brown, Steven B.
2000-01-01
A chemically and mechanically robust optical Raman spectroscopy probe assembly that can be incorporated in a cone penetrometer (CPT) for subsurface deployment. This assembly consists of an optical Raman probe and a penetrometer compatible optical probe housing. The probe is intended for in-situ chemical analysis of chemical constituents in the surrounding environment. The probe is optically linked via fiber optics to the light source and the detection system at the surface. A built-in broadband light source provides a strobe method for direct measurement of sample optical density. A mechanically stable sapphire window is sealed directly into the side-wall of the housing using a metallic, chemically resistant, hermetic seal design. This window permits transmission of the interrogation light beam and the resultant signal. The spectroscopy probe assembly is capable of accepting Raman, Laser induced Fluorescence, reflectance, and other optical probes with collimated output for CPT deployment.
Stroboscopic Vision as a Treatment for Space Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Somers, J.T.; Ford, G.; Krnavek, J.M.; Hwang, E.Y.
2006-01-01
Stroboscopic illumination reduces the severity of motion sickness symptoms, and shutter glasses with a flash frequency of 4 Hz are as effective as a strobe light. Stroboscopic illumination appears to be an effective countermeasure where retinal slip is a significant factor in eliciting motion sickness. Additional research is currently underway to evaluate the stroboscopic glasses efficacy in a variety of different motion environments. Specifically, carsickness, sickness during the microgravity periods of parabolic flight and sea sickness. Possible mechanisms underlying the effectiveness of the glasses are also being investigated. There is evidence from pilot studies showing that the glasses, when strobed at the 4 Hz frequency, reduce saccade velocity to visually presented targets is reduced by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.
Miehls, Scott M.; Johnson, Nicholas S.; Hrodey, Pete J.
2017-01-01
Control of the invasive Sea Lamprey Petromyzon marinus is critical for management of commercial and recreational fisheries in the Laurentian Great Lakes. Use of physical barriers to block Sea Lampreys from spawning habitat is a major component of the control program. However, the resulting interruption of natural streamflow and blockage of nontarget species present substantial challenges. Development of an effective nonphysical barrier would aid the control of Sea Lampreys by eliminating their access to spawning locations while maintaining natural streamflow. We tested the effect of a nonphysical barrier consisting of strobe lights, low-frequency sound, and a bubble screen on the movement of Sea Lampreys in an experimental raceway designed as a two-choice maze with a single main channel fed by two identical inflow channels (one control and one blocked). Sea Lampreys were more likely to move upstream during trials when the strobe light and low-frequency sound were active compared with control trials and trials using the bubble screen alone. For those Sea Lampreys that did move upstream to the confluence of inflow channels, no combination of stimuli or any individual stimulus significantly influenced the likelihood that Sea Lampreys would enter the blocked inflow channel, enter the control channel, or return downstream.
Rao, Anirudh; Brück, Katharina; Methven, Shona; Evans, Rebecca; Stel, Vianda S; Jager, Kitty J; Hooft, Lotty; Ben-Shlomo, Yoav; Caskey, Fergus
2016-01-01
The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) statement was published in October 2007 to improve quality of reporting of observational studies. The aim of this review was to assess the impact of the STROBE statement on observational study reporting and study design quality in the nephrology literature. Systematic literature review. European and North American, Pre-dialysis Chronic Kidney Disease (CKD) cohort studies. Studies assessing the association between CKD and mortality in the elderly (>65 years) published from 1st January 2002 to 31st December 2013 were included, following systematic searching of MEDLINE & EMBASE. Time period before and after the publication of the STROBE statement. Quality of study reporting using the STROBE statement and quality of study design using the Newcastle Ottawa Scale (NOS), Scottish Intercollegiate Guidelines Network (SIGN) and Critical Appraisal Skills Programme (CASP) tools. 37 papers (11 Pre & 26 Post STROBE) were identified from 3621 potential articles. Only four of the 22 STROBE items and their sub-criteria (objectives reporting, choice of quantitative groups and description of and carrying out sensitivity analysis) showed improvements, with the majority of items showing little change between the period before and after publication of the STROBE statement. Pre- and post-period analysis revealed a Manuscript STROBE score increase (median score 77.8% (Inter-quartile range [IQR], 64.7-82.0) vs 83% (IQR, 78.4-84.9, p = 0.05). There was no change in quality of study design with identical median scores in the two periods for NOS (Manuscript NOS score 88.9), SIGN (Manuscript SIGN score 83.3) and CASP (Manuscript CASP score 91.7) tools. Only 37 Studies from Europe and North America were included from one medical specialty. Assessment of study design largely reliant on good reporting. This study highlights continuing deficiencies in the reporting of STROBE items and their sub-criteria in cohort studies in nephrology. There was weak evidence of improvement in the overall reporting quality, with no improvement in methodological quality of CKD cohort studies between the period before and after publication of the STROBE statement.
2008-11-01
Endress & Hauser Analog Level Gauge PV with Sight Glass Minco Temperature Transmitters (2) Steam Pressure Alarm Switch ABB Kent Taylor...Transmitter SV (0-100 psig range) LogTec Pressure Transmitter PV (0-60 psig) Strobe Light Rotor Proximity Switches (3) Endress & Hauser ... Endress & Hauser Analog Level Gauge PV with Sight Glass Minco Temperature Transmitters (2) Steam Pressure Alarm Switch ABB Kent Taylor
Electrolysis Bubbles Make Waterflow Visible
NASA Technical Reports Server (NTRS)
Schultz, Donald F.
1990-01-01
Technique for visualization of three-dimensional flow uses tiny tracer bubbles of hydrogen and oxygen made by electrolysis of water. Strobe-light photography used to capture flow patterns, yielding permanent record that is measured to obtain velocities of particles. Used to measure simulated mixing turbulence in proposed gas-turbine combustor and also used in other water-table flow tests.
2014-07-16
ISS040-E-063769 (16 July 2014) --- Intersecting the thin line of Earth?s atmosphere, the Orbital Sciences? Cygnus cargo craft attached to the end of the Canadarm2 robotic arm of the International Space Station is photographed by an Expedition 40 crew member after the two spacecraft converged at 6:36 a.m. (EDT) on July 16, 2014. The red color on Cygnus is a spectral effect from one of Cygnus? strobe lights against the fading light heading into an orbital sunset following grapple.
Hawwash, Dana; Ocké, Marga C.; Berg, Christina; Forsum, Elisabet; Sonestedt, Emily; Wirfält, Elisabet; Åkesson, Agneta; Kolsteren, Patrick; Byrnes, Graham; De Keyzer, Willem; Van Camp, John; Slimani, Nadia; Cevallos, Myriam; Egger, Matthias; Huybrechts, Inge
2016-01-01
Background Concerns have been raised about the quality of reporting in nutritional epidemiology. Research reporting guidelines such as the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement can improve quality of reporting in observational studies. Herein, we propose recommendations for reporting nutritional epidemiology and dietary assessment research by extending the STROBE statement into Strengthening the Reporting of Observational Studies in Epidemiology—Nutritional Epidemiology (STROBE-nut). Methods and Findings Recommendations for the reporting of nutritional epidemiology and dietary assessment research were developed following a systematic and consultative process, coordinated by a multidisciplinary group of 21 experts. Consensus on reporting guidelines was reached through a three-round Delphi consultation process with 53 external experts. In total, 24 recommendations for nutritional epidemiology were added to the STROBE checklist. Conclusion When used appropriately, reporting guidelines for nutritional epidemiology can contribute to improve reporting of observational studies with a focus on diet and health. PMID:27270749
78 FR 8052 - Airworthiness Directives; DASSAULT AVIATION Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-05
... the tail strobe power supply and a hydraulic line. This proposed AD would require modifying the tail strobe power supply wire routing. We are proposing this AD to prevent chafing between the tail strobe power supply and a hydraulic line, which could result in hydraulic fluid leakage and possible fire due...
Brück, Katharina; Methven, Shona; Evans, Rebecca; Stel, Vianda S.; Jager, Kitty J.; Hooft, Lotty; Ben-Shlomo, Yoav; Caskey, Fergus
2016-01-01
Background The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) statement was published in October 2007 to improve quality of reporting of observational studies. The aim of this review was to assess the impact of the STROBE statement on observational study reporting and study design quality in the nephrology literature. Study Design Systematic literature review. Setting & Population European and North American, Pre-dialysis Chronic Kidney Disease (CKD) cohort studies. Selection Criteria for Studies Studies assessing the association between CKD and mortality in the elderly (>65 years) published from 1st January 2002 to 31st December 2013 were included, following systematic searching of MEDLINE & EMBASE. Predictor Time period before and after the publication of the STROBE statement. Outcome Quality of study reporting using the STROBE statement and quality of study design using the Newcastle Ottawa Scale (NOS), Scottish Intercollegiate Guidelines Network (SIGN) and Critical Appraisal Skills Programme (CASP) tools. Results 37 papers (11 Pre & 26 Post STROBE) were identified from 3621 potential articles. Only four of the 22 STROBE items and their sub-criteria (objectives reporting, choice of quantitative groups and description of and carrying out sensitivity analysis) showed improvements, with the majority of items showing little change between the period before and after publication of the STROBE statement. Pre- and post-period analysis revealed a Manuscript STROBE score increase (median score 77.8% (Inter-quartile range [IQR], 64.7–82.0) vs 83% (IQR, 78.4–84.9, p = 0.05). There was no change in quality of study design with identical median scores in the two periods for NOS (Manuscript NOS score 88.9), SIGN (Manuscript SIGN score 83.3) and CASP (Manuscript CASP score 91.7) tools. Limitations Only 37 Studies from Europe and North America were included from one medical specialty. Assessment of study design largely reliant on good reporting. Conclusions This study highlights continuing deficiencies in the reporting of STROBE items and their sub-criteria in cohort studies in nephrology. There was weak evidence of improvement in the overall reporting quality, with no improvement in methodological quality of CKD cohort studies between the period before and after publication of the STROBE statement. PMID:27168187
78 FR 33199 - Airworthiness Directives; Dassault Aviation Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
... prompted by reports of chafing between the tail strobe power supply and a hydraulic line. This AD requires modifying the tail strobe power supply wire routing. We are issuing this AD to prevent chafing between the tail strobe power supply and a hydraulic line, which could result in hydraulic fluid leakage and...
Ding, C Y; Cao, Y; Yang, C; Sun, F; Zhan, S Y
2017-01-10
Concerns have been raised about the reporting quality in nutritional epidemiology. Therefore, strengthening the reporting of observational studies in epidemiology-nutritional epidemiology (STROBE-nut) has been proposed by extending the STROBE statement to include additional recommendations on issues related to nutritional epidemiology and dietary assessment, aiming to provide more specific guidelines on how to report observational research in the field. This paper presents a brief introduction to STROBE-nut and also an explanation of the key points in the additional items, with an example illustrating the application of the checklist.
Vandenbroucke, Jan P; von Elm, Erik; Altman, Douglas G; Gøtzsche, Peter C; Mulrow, Cynthia D; Pocock, Stuart J; Poole, Charles; Schlesselman, James J; Egger, Matthias
2007-01-01
Much medical research is observational. The reporting of observational studies is often of insufficient quality. Poor reporting hampers the assessment of the strengths and weaknesses of a study and the generalisability of its results. Taking into account empirical evidence and theoretical considerations, a group of methodologists, researchers, and editors developed the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) recommendations to improve the quality of reporting of observational studies. The STROBE Statement consists of a checklist of 22 items, which relate to the title, abstract, introduction, methods, results and discussion sections of articles. Eighteen items are common to cohort studies, case-control studies and cross-sectional studies and four are specific to each of the three study designs. The STROBE Statement provides guidance to authors about how to improve the reporting of observational studies and facilitates critical appraisal and interpretation of studies by reviewers, journal editors and readers. This explanatory and elaboration document is intended to enhance the use, understanding, and dissemination of the STROBE Statement. The meaning and rationale for each checklist item are presented. For each item, one or several published examples and, where possible, references to relevant empirical studies and methodological literature are provided. Examples of useful flow diagrams are also included. The STROBE Statement, this document, and the associated Web site (http://www.strobe-statement.org/) should be helpful resources to improve reporting of observational research. PMID:17941715
Fitchett, Elizabeth J A; Seale, Anna C; Vergnano, Stefania; Sharland, Michael; Heath, Paul T; Saha, Samir K; Agarwal, Ramesh; Ayede, Adejumoke I; Bhutta, Zulfiqar A; Black, Robert; Bojang, Kalifa; Campbell, Harry; Cousens, Simon; Darmstadt, Gary L; Madhi, Shabir A; Meulen, Ajoke Sobanjo-Ter; Modi, Neena; Patterson, Janna; Qazi, Shamim; Schrag, Stephanie J; Stoll, Barbara J; Wall, Stephen N; Wammanda, Robinson D; Lawn, Joy E
2016-10-01
Neonatal infections are estimated to account for a quarter of the 2·8 million annual neonatal deaths, as well as approximately 3% of all disability-adjusted life-years. Despite this burden, few data are available on incidence, aetiology, and outcomes, particularly regarding impairment. We aimed to develop guidelines for improved scientific reporting of observational neonatal infection studies, to increase comparability and to strengthen research in this area. This checklist, Strengthening the Reporting of Observational Studies in Epidemiology for Newborn Infection (STROBE- NI), is an extension of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement. STROBE-NI was developed following systematic reviews of published literature (1996-2015), compilation of more than 130 potential reporting recommendations, and circulation of a survey to relevant professionals worldwide, eliciting responses from 147 professionals from 37 countries. An international consensus meeting of 18 participants (with expertise in infectious diseases, neonatology, microbiology, epidemiology, and statistics) identified priority recommendations for reporting, additional to the STROBE statement. Implementation of these STROBE-NI recommendations, and linked checklist, aims to improve scientific reporting of neonatal infection studies, increasing data utility and allowing meta-analyses and pathogen-specific burden estimates to inform global policy and new interventions, including maternal vaccines. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vandenbroucke, Jan P; von Elm, Erik; Altman, Douglas G; Gøtzsche, Peter C; Mulrow, Cynthia D; Pocock, Stuart J; Poole, Charles; Schlesselman, James J; Egger, Matthias
2014-12-01
Much medical research is observational. The reporting of observational studies is often of insufficient quality. Poor reporting hampers the assessment of the strengths and weaknesses of a study and the generalisability of its results. Taking into account empirical evidence and theoretical considerations, a group of methodologists, researchers, and editors developed the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) recommendations to improve the quality of reporting of observational studies. The STROBE Statement consists of a checklist of 22 items, which relate to the title, abstract, introduction, methods, results and discussion sections of articles. Eighteen items are common to cohort studies, case-control studies and cross-sectional studies and four are specific to each of the three study designs. The STROBE Statement provides guidance to authors about how to improve the reporting of observational studies and facilitates critical appraisal and interpretation of studies by reviewers, journal editors and readers. This explanatory and elaboration document is intended to enhance the use, understanding, and dissemination of the STROBE Statement. The meaning and rationale for each checklist item are presented. For each item, one or several published examples and, where possible, references to relevant empirical studies and methodological literature are provided. Examples of useful flow diagrams are also included. The STROBE Statement, this document, and the associated Web site (http://www.strobe-statement.org/) should be helpful resources to improve reporting of observational research. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sargeant, J M; O'Connor, A M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-12-01
Reporting of observational studies in veterinary research presents challenges that often are not addressed in published reporting guidelines. Our objective was to develop an extension of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement that addresses unique reporting requirements for observational studies in veterinary medicine related to health, production, welfare, and food safety. We conducted a consensus meeting with 17 experts in Mississauga, Canada. Experts completed a premeeting survey about whether items in the STROBE statement should be modified or added to address unique issues related to observational studies in animal species with health, production, welfare, or food safety outcomes. During the meeting, each STROBE item was discussed to determine whether or not rewording was recommended, and whether additions were warranted. Anonymous voting was used to determine consensus. Six items required no modifications or additions. Modifications or additions were made to the STROBE items 1 (title and abstract), 3 (objectives), 5 (setting), 6 (participants), 7 (variables), 8 (data sources and measurement), 9 (bias), 10 (study size), 12 (statistical methods), 13 (participants), 14 (descriptive data), 15 (outcome data), 16 (main results), 17 (other analyses), 19 (limitations), and 22 (funding). The methods and processes used were similar to those used for other extensions of the STROBE statement. The use of this STROBE statement extension should improve reporting of observational studies in veterinary research by recognizing unique features of observational studies involving food-producing and companion animals, products of animal origin, aquaculture, and wildlife.
Power saver circuit for audio/visual signal unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Right, R. W.
1985-02-12
A combined audio and visual signal unit with the audio and visual components actuated alternately and powered over a single cable pair in such a manner that only one of the audio and visual components is drawing power from the power supply at any given instant. Thus, the power supply is never called upon to provide more energy than that drawn by the one of the components having the greater power requirement. This is particularly advantageous when several combined audio and visual signal units are coupled in parallel on one cable pair. Typically, the signal unit may comprise a hornmore » and a strobe light for a fire alarm signalling system.« less
Improvement of a Vocal Fold Imaging System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauter, K. G.
Medical professionals can better serve their patients through continual update of their imaging tools. A wide range of pathologies and disease may afflict human vocal cords or, as they’re also known, vocal folds. These diseases can affect human speech hampering the ability of the patient to communicate. Vocal folds must be opened for breathing and the closed to produce speech. Currently methodologies to image markers of potential pathologies are difficult to use and often fail to detect early signs of disease. These current methodologies rely on a strobe light and slower frame rate camera in an attempt to obtain imagesmore » as the vocal folds travel over the full extent of their motion.« less
Visualization of hydrodynamic pilot-wave dynamics
NASA Astrophysics Data System (ADS)
Prost, Victor; Quintela, Julio; Harris, Daniel; Brun, Pierre-Thomas; Bush, John
2015-11-01
We present a low-cost device for examining the dynamics of droplets bouncing on a vibrating fluid bath, suitable for educational purposes. Dual control of vibrational and strobing frequency from a cell phone application allowed us to reduce the total cost to 60 dollars. Illumination with inhomogeneous colored light allows for striking visualization of the droplet dynamics and accompanying wave field via still photography or high-speed videography. Thanks to the NSF.
Optical countermeasures against CLOS weapon systems
NASA Astrophysics Data System (ADS)
Toet, Alexander; Benoist, Koen W.; van Lingen, Joost N. J.; Schleijpen, H. Ric M. A.
2013-10-01
There are many weapon systems in which a human operator acquires a target, tracks it and designates it. Optical countermeasures against this type of systems deny the operator the possibility to fulfill this visual task. We describe the different effects that result from stimulation of the human visual system with high intensity (visible) light, and the associated potential operational impact. Of practical use are flash blindness, where an intense flash of light produces a temporary "blind-spot" in (part of) the visual field, flicker distraction, where strong intensity and/or color changes at a discomfortable frequency are produced, and disability glare where a source of light leads to contrast reduction. Hence there are three possibilities to disrupt the visual task of an operator with optical countermeasures such as flares or lasers or a combination of these; namely, by an intense flash of light, by an annoying light flicker or by a glare source. A variety of flares for this purpose is now available or under development: high intensity flash flares, continuous burning flares or strobe flares which have an oscillating intensity. The use of flare arrays seems particularly promising as an optical countermeasure. Lasers are particularly suited to interfere with human vision, because they can easily be varied in intensity, color and size, but they have to be directed at the (human) target, and issues like pointing and eye-safety have to be taken into account. Here we discuss the design issues and the operational impact of optical countermeasures against human operators.
Lighting Systems For High Speed Photography Applying Special Metal Halide Discharge Lamps
NASA Astrophysics Data System (ADS)
Gillum, Keith M.; Steuernagel, K. H.
1983-03-01
High speed photography requires, in addition to a good color quality of the light source, a very high level of illumination. Conventional lighting systems utilizing incandescent lamps or other metal halide lamp types has inherent problems of inefficient light output or poor color quality. Heat generated by incandescent lamps and the power these sources require drive up operating and installation costs. A most economical and practical solution was devised by using the metal halide discharge lamp developed by OSRAM, GmbH of Munich, West Germany. This lamp trade marked the HMITM Metallogen was primarily developed for the needs of the television and motion picture film industry. Due to their high efficiency and other consistent operating qualities these lamps also fulfill the needs of high speed photography, e.g. in crash test facilities, when special engineering activities are carried out. The OSRAM HMITM lamp is an AC discharge metal halide lamp with rare earth additives to increase both the efficiency and light output qualities. Since the lamp is an AC source, a special method had to be developed to overcome the strobing effect, which is normal for AC lamps given their modulated light output, when used with high speed cameras, (e.g. with >1000 fps). This method is based on an increased frequency for the lamp supply voltage coupled with a mix of the light output achieved using a multiphase mains power supply. First developed in 1977, this system using the OSRAM HMITM lamps was installed in a crash test facility of a major automotive manufacturer in West Germany. The design resulted in the best lighting and performance ever experienced. Since that time several other motor companies have made use of this breakthrough. Industrial and scientific users are now considering additional applications use of this advanced high speed lighting system.
Sargeant, J M; O'Connor, A M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-11-01
Reporting of observational studies in veterinary research presents challenges that often are not addressed in published reporting guidelines. To develop an extension of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement that addresses unique reporting requirements for observational studies in veterinary medicine related to health, production, welfare, and food safety. Consensus meeting of experts. Mississauga, Canada. Seventeen experts from North America, Europe, and Australia. Experts completed a pre-meeting survey about whether items in the STROBE statement should be modified or added to address unique issues related to observational studies in animal species with health, production, welfare, or food safety outcomes. During the meeting, each STROBE item was discussed to determine whether or not rewording was recommended and whether additions were warranted. Anonymous voting was used to determine consensus. Six items required no modifications or additions. Modifications or additions were made to the STROBE items 1 (title and abstract), 3 (objectives), 5 (setting), 6 (participants), 7 (variables), 8 (data sources/measurement), 9 (bias), 10 (study size), 12 (statistical methods), 13 (participants), 14 (descriptive data), 15 (outcome data), 16 (main results), 17 (other analyses), 19 (limitations), and 22 (funding). The methods and processes used were similar to those used for other extensions of the STROBE statement. The use of this STROBE statement extension should improve reporting of observational studies in veterinary research by recognizing unique features of observational studies involving food-producing and companion animals, products of animal origin, aquaculture, and wildlife. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
1977-06-01
Report for Period 3 June 1975 -- 22 October 1976 Approved for public relleas; distribution unlimritedZ] GENERAL OFFICER PANEL. FOR SAFETY MAIfTERS...LI.USAF DEPUTY INSPECTOR GENERAL C2WASHINGTON, DC 2O3ýO AVIONICS AND AIRCRAFT ACCESSORIES SPO O ’CT 36 1977 DEPUTY FOR AEkONAUTICAL EQUIPMENT WRIGHT...01) and is zeleaiable to the National Technical Information Service (NTIS). At WrIS, i- will be available to the general public, including foreign
NASA Astrophysics Data System (ADS)
Ballantyne, David; Balokovic, Mislav; Garcia, Javier; Koss, Michael; STROBE-X
2018-01-01
The probe concept STROBE-X, with its combination of large collecting area, wide-field monitor, broad bandpass, and rapid timing capability, is a powerful tool for studying many aspects of AGN astrophysics. This unique combination of features opens up the possibility for studying AGNs in ways current and other future missions are unable to accomplish. Here, we show a few of the novel new investigations made possible by STROBE-X: probing the structure of the BLR and torus with reverberation of the narrow Fe Kα line and line-of-sight column density, tracking changes in coronal parameters, investigating the origin of the soft excess, Fe Kα emission line surveys, and efficient Compton-thick characterization. Additional ideas and suggestions are always welcome and can be communicated to any member of the STROBE-X team.
McEwan, Thomas E.
1994-01-01
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, .+-.UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals.
McEwan, Thomas E.
1996-01-01
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, .+-.UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals.
Buffered coscheduling for parallel programming and enhanced fault tolerance
Petrini, Fabrizio [Los Alamos, NM; Feng, Wu-chun [Los Alamos, NM
2006-01-31
A computer implemented method schedules processor jobs on a network of parallel machine processors or distributed system processors. Control information communications generated by each process performed by each processor during a defined time interval is accumulated in buffers, where adjacent time intervals are separated by strobe intervals for a global exchange of control information. A global exchange of the control information communications at the end of each defined time interval is performed during an intervening strobe interval so that each processor is informed by all of the other processors of the number of incoming jobs to be received by each processor in a subsequent time interval. The buffered coscheduling method of this invention also enhances the fault tolerance of a network of parallel machine processors or distributed system processors
Using a fidget spinner to teach physics
NASA Astrophysics Data System (ADS)
Mesquita, Lucas; Brockington, Guilherme; Aline de Almeida, Pamella; Truyol, Maria Elena; André Testoni, Leonardo; Sousa, Paula F. F.
2018-07-01
In 2017, almost everywhere in the world, there was a boom in sales of fidget spinners. A toy that has ‘multi-lobes’ that can rotate freely from a thrust performed with the fingers. Thereby, we analysed the physics concepts that involved in this toy, such as angular and linear velocity. We did the analysis using the software Tracker, a laboratory light sensor, a free mobile application that turns the device flashlight into a strobe light source. Thus, we aim to show that it is possible to transform a well-known toy into an opportunity to work on physics concepts and to construct experiments in the classroom.
McEwan, T.E.
1994-09-06
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, [+-] UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals. 16 figs.
McEwan, T.E.
1996-06-04
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, {+-}UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals. 21 figs.
Goi, Pedro Domingues; Goi, Julia Domingues; Cordini, Kariny Larissa; Ceresér, Keila Mendes; Rocha, Neusa Sica da
2014-01-01
Case-control studies are important in developing clinical and public health knowledge. The STROBE statement (STrengthening the Reporting of OBservational Studies in Epidemiology) was developed to establish a checklist of items that should be included in articles reporting observational studies. Our aim was to analyze whether the psychiatric case-control articles published in Brazilian journals with CAPES Qualis rating B1/B2 in 2009 conformed with the STROBE statement. Descriptive study on psychiatric papers published in Brazilian journals, within the Postgraduate Medical Program on Psychiatry, at Universidade Federal do Rio Grande do Sul. All psychiatric case-control studies from Brazilian Qualis B1/B2 journals of psychiatry, neurology and public health in 2009 were analyzed. The four most specific items of the STROBE statement were used to evaluate whether these studies fitted within the case-control parameters: 1) selection of cases and controls; 2) controlling for bias; 3) statistical analysis; and 4) presentation of results. Sixteen case-control studies were identified, of which eleven (68.75%) were in psychiatry-focused journals. From analysis using the STROBE statement, all of the articles conformed with item 1; two (12.5%) completely conformed with item 2; none completely conformed with item 3; and only three (18.8%) conformed with item 4. The case-control studies analyzed here did not completely conform with the four STROBE statement items for case-control design. In view of the inadequate methodology of the published studies, these findings justify focusing on research and methodology and expanding the investigations on adherence of studies to their designs.
Fung, Anne E; Palanki, Ram; Bakri, Sophie J; Depperschmidt, Eric; Gibson, Andrea
2009-02-01
To evaluate the quality of reporting in the neovascular age-related macular degeneration (nvAMD) literature by applying the Consolidated Standards for Reporting Trials (CONSORT) and Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement writing standards. CONSORT and STROBE impact analysis; literature review. Phase III randomized controlled trials (RCTs) of verteporfin photodynamic therapy, pegaptanib, and ranibizumab, and interventional case studies of bevacizumab for nvAMD. A literature search identified eligible articles published before October 31, 2007. We assessed the report quality of Phase III RCTs using the CONSORT statement and case series publications using the STROBE statement, both with indicators relevant to nvAMD. Presence or absence of CONSORT or STROBE statement indicators. Seven publications of Phase III RCTs and 29 publications on bevacizumab interventional case studies for nvAMD met our inclusion criteria. Of 37 possible CONSORT writing guideline items, the mean report quality for RCTs was 30.6 (83%), with a range from 23 to 35 (65%-95%). Of 35 possible STROBE writing guideline items, the mean report quality grade for intravitreal bevacizumab case series was 23 (70%), with a range from 16 to 31 (46%-94%). Among the bevacizumab studies, more than 90% reported scientific background, drug dose and administration, baseline characteristics, unadjusted results, and adverse events. Fewer than 20% reported study size calculations, handling of missing data, or a discussion of bias. Since the adoption of the CONSORT standards by Ophthalmology and other journals in 1996, the reporting quality for RCTs has further improved among this cohort of nvAMD articles. On the other hand, no reporting standards for case series have existed until the recent publication of the STROBE statement. In this first application of the STROBE standards to ophthalmology, we found that the small interventional studies in our series had an average reporting score lower than the RCTs, but also that some individual scores were higher than the RCTs. This outcome demonstrates that good, useful articles can be written about small studies. Although not a direct measure of the quality of a study, good reporting allows a reader to assess the validity and applicability of the study's findings. Proprietary or commercial disclosure may be found after the references.
2007-10-20
KENNEDY SPACE CENTER, FLA. -- The left position light, strobe light and wing tip of one of NASA's Shuttle Training Aircraft, or STAs, sustained minor damage from apparent contact with a tree near Kennedy Space Center's Shuttle Landing Facility. The incident occurred during landing about 6:30 p.m. EDT Oct. 19 following a training session. An STA flight instructor was piloting the aircraft. The flight crew was unaware of any contact with the tree, and there were no injuries. Thunderstorms were in the area at the time of the incident, which is under investigation. The STA is a twin-engine Gulfstream II jet that was modified to simulate a space shuttle during landing. Photo credit: NASA/Kim Shiflett
2007-10-20
KENNEDY SPACE CENTER, FLA. -- The left position light, strobe light and wing tip of one of NASA's Shuttle Training Aircraft, or STA, show signs of minor damage from apparent contact with a tree near Kennedy Space Center's Shuttle Landing Facility. The incident occurred during landing about 6:30 p.m. EDT Oct. 19 following a training session. An STA flight instructor was piloting the aircraft. The flight crew was unaware of any contact with the tree, and there were no injuries. Thunderstorms were in the area at the time of the incident, which is under investigation. The STA is a twin-engine Gulfstream II jet that was modified to simulate a space shuttle during landing. Photo credit: NASA/Kim Shiflett
Electronic Flash In Data Acquisition
NASA Astrophysics Data System (ADS)
Miller, C. E.
1982-02-01
Photographic acquisition of data often may be simplified, or the data quality improved upon by employing electronic flash sources with traditional equipment or techniques. The relatively short flash duration compared to movie camera shutters, or to the long integration time of video camera provides improved spatial resolution through blur reduction, particularly important as image movement becomes a significant fraction of film format dimension. Greater accuracy typically is achieved in velocity and acceleration determinations by using a stroboscopic light source rather than a movie camera frame-rate control as a time standard. Electrical efficiency often is an important advantage of electronic flash sources since almost any necessary light level for exposure may be produced, yet the source typically is "off" most of the time. Various synchronization techniques greatly expand the precise control of exposure. Biomechanical and sports equipment studies may involve velocities up to 200 feet-per-second, and often will have associated very rapid actions of interest. The need for brief exposures increases H.s one "ZOOMS in on the action." In golf, for example, the swing may be examined using 100 microsecond (Us) flashes at rates of 60 or 120 flashes-per-second (FPS). Accurate determination of linear and rotational velocity of the ball requires 10 Us flashes at 500-1,000 FPS, while sub-Us flashes at 20,000-50,000 FPS are required to resolve the interaction of the ball and the club, head. Some seldom. used techniques involving streak photography are described, with enhanced results obtained by combining strobe with the usual continuous light source. The combination of strobe and a fast electro-mechanical shutter is considered for Us photography under daylight conditions.
Sargeant, J M; O'Connor, A M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-11-01
The reporting of observational studies in veterinary research presents many challenges that often are not adequately addressed in published reporting guidelines. To develop an extension of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement that addresses unique reporting requirements for observational studies in veterinary medicine related to health, production, welfare, and food safety. A consensus meeting of experts was organized to develop an extension of the STROBE statement to address observational studies in veterinary medicine with respect to animal health, animal production, animal welfare, and food safety outcomes. Consensus meeting May 11-13, 2014 in Mississauga, Ontario, Canada. Seventeen experts from North America, Europe, and Australia attended the meeting. The experts were epidemiologists and biostatisticians, many of whom hold or have held editorial positions with relevant journals. Prior to the meeting, 19 experts completed a survey about whether they felt any of the 22 items of the STROBE statement should be modified and if items should be added to address unique issues related to observational studies in animal species with health, production, welfare, or food safety outcomes. At the meeting, the participants were provided with the survey responses and relevant literature concerning the reporting of veterinary observational studies. During the meeting, each STROBE item was discussed to determine whether or not re-wording was recommended, and whether additions were warranted. Anonymous voting was used to determine whether there was consensus for each item change or addition. The consensus was that six items needed no modifications or additions. Modifications or additions were made to the STROBE items numbered: 1 (title and abstract), 3 (objectives), 5 (setting), 6 (participants), 7 (variables), 8 (data sources/measurement), 9 (bias), 10 (study size), 12 (statistical methods), 13 (participants), 14 (descriptive data), 15 (outcome data), 16 (main results), 17 (other analyses), 19 (limitations), and 22 (funding). Published literature was not always available to support modification to, or inclusion of, an item. The methods and processes used in the development of this statement were similar to those used for other extensions of the STROBE statement. The use of this extension to the STROBE statement should improve the reporting of observational studies in veterinary research related to animal health, production, welfare, or food safety outcomes by recognizing the unique features of observational studies involving food-producing and companion animals, products of animal origin, aquaculture, and wildlife. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
School Science Review, 1980
1980-01-01
Outlines a variety of laboratory procedures, discussions, and demonstrations including a no-solder circuit board, damped to maintained oscillations with L-C circuits, polaroid strobe photos, resistive putty, soldering and circuit checking exercise, electromagnetic radiation, square pulses in C-R circuits, and testing an oscillating system. (GS)
Inexpensive Strobe-Like Photographs
ERIC Educational Resources Information Center
Medeiros, Emil L.; Tavares, Odilon A. P.; Duarte, Sergio B.
2009-01-01
This paper reports on a technique the authors have developed to produce and analyze, at very low cost, good quality strobe-like photographs. While the concept is similar to the one described by Graney and DiNoto, the strategy described here benefits from recent advances in the fields of digital photography and related software to significantly…
von Elm, Erik; Altman, Douglas G; Egger, Matthias; Pocock, Stuart J; Gøtzsche, Peter C; Vandenbroucke, Jan P
2014-12-01
Much biomedical research is observational. The reporting of such research is often inadequate, which hampers the assessment of its strengths and weaknesses and of a study's generalisability. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Initiative developed recommendations on what should be included in an accurate and complete report of an observational study. We defined the scope of the recommendations to cover three main study designs: cohort, case-control, and cross-sectional studies. We convened a 2-day workshop in September 2004, with methodologists, researchers, and journal editors to draft a checklist of items. This list was subsequently revised during several meetings of the coordinating group and in e-mail discussions with the larger group of STROBE contributors, taking into account empirical evidence and methodological considerations. The workshop and the subsequent iterative process of consultation and revision resulted in a checklist of 22 items (the STROBE Statement) that relate to the title, abstract, introduction, methods, results, and discussion sections of articles. 18 items are common to all three study designs and four are specific for cohort, case-control, or cross-sectional studies. A detailed Explanation and Elaboration document is published separately and is freely available on the Web sites of PLoS Medicine, Annals of Internal Medicine, and Epidemiology. We hope that the STROBE Statement will contribute to improving the quality of reporting of observational studies. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
2007-10-20
KENNEDY SPACE CENTER, FLA. -- Debris from apparent contact with a tree near Kennedy Space Center's Shuttle Landing Facility can be seen in the strobe light cavity on the left side of one of NASA's Shuttle Training Aircraft, or STA. The left position light and wing tip also received minor damage. The incident occurred during landing about 6:30 p.m. EDT Oct. 19 following a training session. An STA flight instructor was piloting the aircraft. The flight crew was unaware of any contact with the tree, and there were no injuries. Thunderstorms were in the area at the time of the incident, which is under investigation. The STA is a twin-engine Gulfstream II jet that was modified to simulate a space shuttle during landing. Photo credit: NASA/Kim Shiflett
2007-10-20
KENNEDY SPACE CENTER, FLA. -- Debris from apparent contact with a tree near Kennedy Space Center's Shuttle Landing Facility can be seen in the position light cavity on the left side of one of NASA's Shuttle Training Aircraft, or STA. The left strobe light and wing tip also received minor damage. The incident occurred during landing about 6:30 p.m. EDT Oct. 19 following a training session. An STA flight instructor was piloting the aircraft. The flight crew was unaware of any contact with the tree, and there were no injuries. Thunderstorms were in the area at the time of the incident, which is under investigation. The STA is a twin-engine Gulfstream II jet that was modified to simulate a space shuttle during landing. Photo credit: NASA/Kim Shiflett
Sargeant, J M; O'Connor, A M; Dohoo, I R; Erb, H N; Cevallos, M; Egger, M; Ersbøll, A K; Martin, S W; Nielsen, L R; Pearl, D L; Pfeiffer, D U; Sanchez, J; Torrence, M E; Vigre, H; Waldner, C; Ward, M P
2016-12-01
The reporting of observational studies in veterinary research presents many challenges that often are not adequately addressed in published reporting guidelines. A consensus meeting of experts was organized to develop an extension of the STROBE statement to address observational studies in veterinary medicine with respect to animal health, animal production, animal welfare and food safety outcomes. The consensus meeting was held 11-13 May 2014 in Mississauga, Ontario, Canada. Seventeen experts from North America, Europe and Australia attended the meeting. The experts were epidemiologists and biostatisticians, many of whom hold or have held editorial positions with relevant journals. Prior to the meeting, 19 experts completed a survey about whether they felt any of the 22 items of the STROBE statement should be modified and whether items should be added to address unique issues related to observational studies in animal species with health, production, welfare or food safety outcomes. At the meeting, the participants were provided with the survey responses and relevant literature concerning the reporting of veterinary observational studies. During the meeting, each STROBE item was discussed to determine whether or not re-wording was recommended, and whether additions were warranted. Anonymous voting was used to determine whether there was consensus for each item change or addition. The consensus was that six items needed no modifications or additions. Modifications or additions were made to the STROBE items numbered as follows: 1 (title and abstract), 3 (objectives), 5 (setting), 6 (participants), 7 (variables), 8 (data sources/measurement), 9 (bias), 10 (study size), 12 (statistical methods), 13 (participants), 14 (descriptive data), 15 (outcome data), 16 (main results), 17 (other analyses), 19 (limitations) and 22 (funding). Published literature was not always available to support modification to, or inclusion of, an item. The methods and processes used in the development of this statement were similar to those used for other extensions of the STROBE statement. The use of this extension to the STROBE statement should improve the reporting of observational studies in veterinary research related to animal health, production, welfare or food safety outcomes by recognizing the unique features of observational studies involving food-producing and companion animals, products of animal origin, aquaculture and wildlife. © 2016 The Authors. Zoonoses and Public Health published by Blackwell Verlag GmbH.
Effect of Strontium Nitrate on Extremely Slow Strobe Compositions
2017-01-01
SUBJECT TERMS Strobe Hang fire Flash Orion’s Flashing Guns 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF... Guns Formulations .......................................................................2 2. Modifications of Orion’s Flashing Guns , Resulting...Flashing Guns ” (3). These compositions used barium nitrate as the oxidizer and magnalium as the fuel. Both also contained a substantial amount of sulfur
[STandardized Reporting Of Secondary data Analyses (STROSA)—a recommendation].
Swart, Enno; Schmitt, Jochen
2014-01-01
Secondary data analyses will play an increasingly important role in health services research. But to date, there is no guideline for the systematic, transparent and complete reporting of secondary data. We investigated whether the STROBE statement, i.e., the recommendations for reporting observational studies, satisfies the specific characteristics of secondary data analyses and whether any specifications/modifications and extensions are necessary. For the majority of the 22 STROBE criteria, specifications and extensions are needed to meet the requirements of systematic, transparent and complete reporting of secondary data analysis. Seven aspects of secondary data analysis not covered by STROBE (legal aspects, data flow, protocol, unit of analysis, internal validations/definitions, advantages of secondary data utilisation, role of data owners) should be considered as a specific complement to STROBE. The so called STROSA (STandardized Reporting Of Secondary data Analyses) checklist therefore includes 29 items that relate to the title/abstract, introduction, methods, results and discussion sections of articles. The STROSA checklist is intended to support authors and readers in the critical appraisal of secondary data analyses. This proposal will now be subject to continued scientific discussions. Copyright © 2014. Published by Elsevier GmbH.
Perry, R.W.; Farley, M.J.; Hansen, G.S.; Shurtleff, D.J.; Rondorf, D.W.; LeCaire, R.
2003-01-01
In 1995, the Chief Joseph Kokanee Enhancement Project was established to mitigate the loss of anadromous fish due to the construction of Chief Joseph and Grand Coulee dams. The objectives of the Chief Joseph Enhancement Project are to determine the status of resident kokanee (Oncorhynchus nerka) populations above Chief Joseph and Grand Coulee dams and to enhance kokanee and rainbow trout (Oncorhynchus mykiss) populations. Studies conducted at Grand Coulee Dam documented substantial entrainment of kokanee through turbines at the third powerhouse.
Hydraulic flow visualization method and apparatus
Karidis, Peter G.
1984-01-01
An apparatus and method for visualizing liquid flow. Pulses of gas bubbles are introduced into a liquid flow stream and a strobe light is operated at a frequency related to the frequency of the gas pulses to shine on the bubbles as they pass through the liquid stream. The gas pulses pass through a probe body having a valve element, and a reciprocating valve stem passes through the probe body to operate the valve element. A stem actuating device comprises a slidable reciprocating member, operated by a crank arm. The actuated member is adjustable to adjust the amount of the valve opening during each pulse.
A remotely triggered fast neutron detection instrument based on a plastic organic scintillator
NASA Astrophysics Data System (ADS)
Jones, A. R.; Aspinall, M. D.; Joyce, M. J.
2018-02-01
A detector system for the characterization of radiation fields of both fast neutrons and γ rays is described comprising of a gated photomultiplier tube (PMT), an EJ299-33 solid organic scintillator detector, and an external trigger circuit. The objective of this development was to conceive a means by which the PMT in such a system can be actuated remotely during the high-intensity bursts of pulsed γ-ray contamination that can arise during active interrogation procedures. The system is used to detect neutrons and γ rays using established pulse-shape discrimination (PSD) techniques. The gating circuit enables the PMT to be switched off remotely. This is compatible with use during intense radiation transients to avoid saturation and the disruption of the operation of the PMT during the burst. Data are presented in the form of pulse-height spectra and PSD scatter plots for the system triggered with a strobed light source. These confirm that the gain of the system and the throughput for both triggered and un-triggered scenarios are as expected, given the duty cycle of the stimulating radiation. This demonstrates that the triggering function does not perturb the system response of the detector.
A remotely triggered fast neutron detection instrument based on a plastic organic scintillator.
Jones, A R; Aspinall, M D; Joyce, M J
2018-02-01
A detector system for the characterization of radiation fields of both fast neutrons and γ rays is described comprising of a gated photomultiplier tube (PMT), an EJ299-33 solid organic scintillator detector, and an external trigger circuit. The objective of this development was to conceive a means by which the PMT in such a system can be actuated remotely during the high-intensity bursts of pulsed γ-ray contamination that can arise during active interrogation procedures. The system is used to detect neutrons and γ rays using established pulse-shape discrimination (PSD) techniques. The gating circuit enables the PMT to be switched off remotely. This is compatible with use during intense radiation transients to avoid saturation and the disruption of the operation of the PMT during the burst. Data are presented in the form of pulse-height spectra and PSD scatter plots for the system triggered with a strobed light source. These confirm that the gain of the system and the throughput for both triggered and un-triggered scenarios are as expected, given the duty cycle of the stimulating radiation. This demonstrates that the triggering function does not perturb the system response of the detector.
Performance Evaluation of the Honeywell GG1308 Miniature Ring Laser Gyroscope
1993-01-01
information. The final display line provides the current DSB configuration status. An external strobe was established between the Contraves motion...components and systems. The core of the facility is a Contraves -Goerz Model 57CD 2-axis motion simulator capable of highly precise position, rate and
Active Flow Control: Instrumentation Automation and Experimental Technique
NASA Technical Reports Server (NTRS)
Gimbert, N. Wes
1995-01-01
In investigating the potential of a new actuator for use in an active flow control system, several objectives had to be accomplished, the largest of which was the experimental setup. The work was conducted at the NASA Langley 20x28 Shear Flow Control Tunnel. The actuator named Thunder, is a high deflection piezo device recently developed at Langley Research Center. This research involved setting up the instrumentation, the lighting, the smoke, and the recording devices. The instrumentation was automated by means of a Power Macintosh running LabVIEW, a graphical instrumentation package developed by National Instruments. Routines were written to allow the tunnel conditions to be determined at a given instant at the push of a button. This included determination of tunnel pressures, speed, density, temperature, and viscosity. Other aspects of the experimental equipment included the set up of a CCD video camera with a video frame grabber, monitor, and VCR to capture the motion. A strobe light was used to highlight the smoke that was used to visualize the flow. Additional effort was put into creating a scale drawing of another tunnel on site and a limited literature search in the area of active flow control.
Digital interface for bi-directional communication between a computer and a peripheral device
NASA Technical Reports Server (NTRS)
Bond, H. H., Jr. (Inventor); Franklin, C. R.
1984-01-01
For transmission of data from the computer to the peripheral, the computer initially clears a flipflop which provides a select signal to a multiplexer. A data available signal or data strobe signal is produced while tht data is being provided to the interface. Setting of the flipflop causes a gate to provide to the peripherial a signal indicating that the interface has data available for transmission. The peripheral provides an acknowledge or strobe signal to transfer the data to the peripheral. For transmission of data from the peripheral to the computer, the computer presents the initially cleared flipflop. A data request signal from the peripheral indicates that the peripheral has data available for transmission to the computer. An acknowledge signal indicates that the interface is ready to receive data from the peripheral and to strobe that data into the interface.
Plasma arc welding weld imaging
NASA Technical Reports Server (NTRS)
Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)
1994-01-01
A welding torch for plasma arc welding apparatus has a transparent shield cup disposed about the constricting nozzle, the cup including a small outwardly extending polished lip. A guide tube extends externally of the torch and has a free end adjacent to the lip. First and second optical fiber bundle assemblies are supported within the guide tube. Light from a strobe light is transmitted along one of the assemblies to the free end and through the lip onto the weld site. A lens is positioned in the guide tube adjacent to the second assembly and focuses images of the weld site onto the end of the fiber bundle of the second assembly and these images are transmitted along the second assembly to a video camera so that the weld site may be viewed continuously for monitoring the welding process.
The effect of microchannel plate gain depression on PAPA photon counting cameras
NASA Astrophysics Data System (ADS)
Sams, Bruce J., III
1991-03-01
PAPA (precision analog photon address) cameras are photon counting imagers which employ microchannel plates (MCPs) for image intensification. They have been used extensively in astronomical speckle imaging. The PAPA camera can produce artifacts when light incident on its MCP is highly concentrated. The effect is exacerbated by adjusting the strobe detection level too low, so that the camera accepts very small MCP pulses. The artifacts can occur even at low total count rates if the image has highly a concentrated bright spot. This paper describes how to optimize PAPA camera electronics, and describes six techniques which can avoid or minimize addressing errors.
Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics.
Philpott, D E; Bailey, P F; Harrison, G; Turnbill, C
1979-01-01
Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.
Field, Nigel; Cohen, Ted; Struelens, Marc J; Palm, Daniel; Cookson, Barry; Glynn, Judith R; Gallo, Valentina; Ramsay, Mary; Sonnenberg, Pam; Maccannell, Duncan; Charlett, Andre; Egger, Matthias; Green, Jonathan; Vineis, Paolo; Abubakar, Ibrahim
2014-04-01
Molecular data are now widely used in epidemiological studies to investigate the transmission, distribution, biology, and diversity of pathogens. Our objective was to establish recommendations to support good scientific reporting of molecular epidemiological studies to encourage authors to consider specific threats to valid inference. The statement Strengthening the Reporting of Molecular Epidemiology for Infectious Diseases (STROME-ID) builds upon the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) initiative. The STROME-ID statement was developed by a working group of epidemiologists, statisticians, bioinformaticians, virologists, and microbiologists with expertise in control of infection and communicable diseases. The statement focuses on issues relating to the reporting of epidemiological studies of infectious diseases using molecular data that were not addressed by STROBE. STROME-ID addresses terminology, measures of genetic diversity within pathogen populations, laboratory methods, sample collection, use of molecular markers, molecular clocks, timeframe, multiple-strain infections, non-independence of infectious-disease data, missing data, ascertainment bias, consistency between molecular and epidemiological data, and ethical considerations with respect to infectious-disease research. In total, 20 items were added to the 22 item STROBE checklist. When used, the STROME-ID recommendations should advance the quality and transparency of scientific reporting, with clear benefits for evidence reviews and health-policy decision making. Copyright © 2014 Elsevier Ltd. All rights reserved.
The STROBE extensions: protocol for a qualitative assessment of content and a survey of endorsement.
Sharp, Melissa K; Utrobičić, Ana; Gómez, Guadalupe; Cobo, Erik; Wager, Elizabeth; Hren, Darko
2017-10-22
The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) Statement was developed in response to inadequate reporting of observational studies. In recent years, several extensions to STROBE have been created to provide more nuanced field-specific guidance for authors. The content and the prevalence of extension endorsement have not yet been assessed. Accordingly, there are two aims: (1) to classify changes made in the extensions to identify strengths and weaknesses of the original STROBE checklist and (2) to determine the prevalence and typology of endorsement by journals in fields related to extensions. Two independent researchers will assess additions in each extension. Additions will be coded as 'field specific' (FS) or 'not field specific' (NFS). FS is defined as particularly relevant information for a single field and guidance provided generally cannot be extrapolated beyond that field. NFS is defined as information that reflects epidemiological or methodological tenets and can be generalised to most, if not all, types of observational research studies. Intraclass correlation will be calculated to measure reviewers' concordance. On disagreement, consensus will be sought. Individual additions will be grouped by STROBE checklist items to identify the frequency and distribution of changes.Journals in fields related to extensions will be identified through National Library of Medicine PubMed Broad Subject Terms, screened for eligibility and further distilled via Ovid MEDLINE® search strategies for observational studies. Text describing endorsement will be extracted from each journal's website. A classification scheme will be created for endorsement types and the prevalence of endorsement will be estimated. Analyses will use NVivo V.11 and SAS University Edition. This study does not require ethical approval as it does not involve human participants. This study has been preregistered on Open Science Framework. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Guitars, Keyboards, Strobes, and Motors--From Vibrational Motion to Active Research
ERIC Educational Resources Information Center
Tagg, Randall; Carlson, John; Asadi-Zeydabadi, Masoud; Busley, Brad; Law-Balding, Katie; Juengel, Mattea
2013-01-01
Physics First is offered to ninth graders at high schools in Aurora, CO. A unique new asset of this school system is an embedded research lab called the "Innovation Hyperlab." The goal of the lab is to connect secondary school teaching to ongoing university scientific research, supporting the school district's aim to create opportunities to…
Disalvo, Domenica; Luckett, Tim; Agar, Meera; Bennett, Alexandra; Davidson, Patricia Mary
2016-05-31
Systems for identifying potentially inappropriate medications in older adults are not immediately transferrable to advanced dementia, where the management goal is palliation. The aim of the systematic review was to identify and synthesise published systems and make recommendations for identifying potentially inappropriate prescribing in advanced dementia. Studies were included if published in a peer-reviewed English language journal and concerned with identifying the appropriateness or otherwise of medications in advanced dementia or dementia and palliative care. The quality of each study was rated using the STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist. Synthesis was narrative due to heterogeneity among designs and measures. Medline (OVID), CINAHL, the Cochrane Database of Systematic Reviews (2005 - August 2014) and AMED were searched in October 2014. Reference lists of relevant reviews and included articles were searched manually. Eight studies were included, all of which were scored a high quality using the STROBE checklist. Five studies used the same system developed by the Palliative Excellence in Alzheimer Care Efforts (PEACE) Program. One study used number of medications as an index, and two studies surveyed health professionals' opinions on appropriateness of specific medications in different clinical scenarios. Future research is needed to develop and validate systems with clinical utility for improving safety and quality of prescribing in advanced dementia. Systems should account for individual clinical context and distinguish between deprescribing and initiation of medications.
Infrared Video Pupillography Coupled with Smart Phone LED for Measurement of Pupillary Light Reflex.
Chang, Lily Yu-Li; Turuwhenua, Jason; Qu, Tian Yuan; Black, Joanna M; Acosta, Monica L
2017-01-01
Clinical assessment of pupil appearance and pupillary light reflex (PLR) may inform us the integrity of the autonomic nervous system (ANS). Current clinical pupil assessment is limited to qualitative examination, and relies on clinical judgment. Infrared (IR) video pupillography combined with image processing software offer the possibility of recording quantitative parameters. In this study we describe an IR video pupillography set-up intended for human and animal testing. As part of the validation, resting pupil diameter was measured in human subjects using the NeurOptics ™ (Irvine, CA, USA) pupillometer, to compare against that measured by our IR video pupillography set-up, and PLR was assessed in guinea pigs. The set-up consisted of a smart phone with a light emitting diode (LED) strobe light (0.2 s light ON, 5 s light OFF cycles) as the stimulus and an IR camera to record pupil kinetics. The consensual response was recorded, and the video recording was processed using a custom MATLAB program. The parameters assessed were resting pupil diameter (D1), constriction velocity (CV), percentage constriction ratio, re-dilation velocity (DV) and percentage re-dilation ratio. We report that the IR video pupillography set-up provided comparable results as the NeurOptics ™ pupillometer in human subjects, and was able to detect larger resting pupil size in juvenile male guinea pigs compared to juvenile female guinea pigs. At juvenile age, male guinea pigs also had stronger pupil kinetics for both pupil constriction and dilation. Furthermore, our IR video pupillography set-up was able to detect an age-specific increase in pupil diameter (female guinea pigs only) and reduction in CV (male and female guinea pigs) as animals developed from juvenile (3 months) to adult age (7 months). This technique demonstrated accurate and quantitative assessment of pupil parameters, and may provide the foundation for further development of an integrated system useful for clinical applications.
Radiation-Tolerant, SpaceWire-Compatible Switching Fabric
NASA Technical Reports Server (NTRS)
Katzman, Vladimir
2011-01-01
Current and future near-Earth and deep space exploration programs and space defense programs require the development of robust intra-spacecraft serial data transfer electronics that must be reconfigurable, fault-tolerant, and have the ability to operate effectively for long periods of time in harsh environmental conditions. Existing data transfer systems based on state-of-the-art serial data transfer protocols or passive backplanes are slow, power-hungry, and poorly reconfigurable. They provide limited expandability and poor tolerance to radiation effects and total ionizing dose (TID) in particular, which presents harmful threats to modern submicron electronics. This novel approach is based on a standard library of differential cells tolerant to TID, and patented, multi-level serial interface architecture that ensures the reliable operation of serial interconnects without application of a data-strobe or other encoding techniques. This proprietary, high-speed differential interface presents a lowpower solution fully compatible with the SpaceWire (SW) protocol. It replaces a dual data-strobe link with two identical independent data channels, thus improving the system s tolerance to harsh environments through additional double redundancy. Each channel incorporates an automatic line integrity control circuitry that delivers error signals in case of broken or shorted lines.
NASA Technical Reports Server (NTRS)
Philpott, D. E.; Harrison, G.; Turnbill, C.; Bailey, P. F.
1979-01-01
Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark-adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.
Inexpensive Strobe-like Photographs
NASA Astrophysics Data System (ADS)
Medeiros, Emil L.; Tavares, Odilon A. P.; Duarte, Sérgio B.
2009-11-01
This paper reports on a technique the authors have developed to produce and analyze, at very low cost, good quality strobe-like photographs like the one shown in Figs. 1(a) and 1(b). While the concept is similar to the one described by Graney and DiNoto, the strategy described here benefits from recent advances in the fields of digital photography and related software to significantly reduce the costs, simplify the production process, and enhance the final quality of photographs of this type, as well as to obtain greater accuracy in measurements made with them.
Real, J; Cleries, R; Forné, C; Roso-Llorach, A; Martínez-Sánchez, J M
In medicine and biomedical research, statistical techniques like logistic, linear, Cox and Poisson regression are widely known. The main objective is to describe the evolution of multivariate techniques used in observational studies indexed in PubMed (1970-2013), and to check the requirements of the STROBE guidelines in the author guidelines in Spanish journals indexed in PubMed. A targeted PubMed search was performed to identify papers that used logistic linear Cox and Poisson models. Furthermore, a review was also made of the author guidelines of journals published in Spain and indexed in PubMed and Web of Science. Only 6.1% of the indexed manuscripts included a term related to multivariate analysis, increasing from 0.14% in 1980 to 12.3% in 2013. In 2013, 6.7, 2.5, 3.5, and 0.31% of the manuscripts contained terms related to logistic, linear, Cox and Poisson regression, respectively. On the other hand, 12.8% of journals author guidelines explicitly recommend to follow the STROBE guidelines, and 35.9% recommend the CONSORT guideline. A low percentage of Spanish scientific journals indexed in PubMed include the STROBE statement requirement in the author guidelines. Multivariate regression models in published observational studies such as logistic regression, linear, Cox and Poisson are increasingly used both at international level, as well as in journals published in Spanish. Copyright © 2015 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.
Koch, Marianne; Riss, Paul; Umek, Wolfgang; Hanzal, Engelbert
2016-03-01
Poor reporting of research may limit critical appraisal and reproducibility, whereas adherence to reporting guidelines (RG) can guarantee completeness and transparency. We aimed to determine the explicit citing of RGs (CONSORT, PRISMA, STROBE) in urogynecology articles in 2013, the requirements of relevant journals and a potential difference between urogynecology and general gynecology journals. All urogynecologic articles published between January and December 2013 in the journals NAU, IUJ, FPMRS, GREEN, AJOG, and BJOG were included. Issues were searched for systematic reviews, RCTs, cohort studies, case-control studies and cross-sectional studies. Each electronic article was searched for the term PRISMA, CONSORT, or STROBE according to the study design. Instructions to Authors of the six journals were screened for requirement of using RGs. We included 296 articles (243 observational studies, 40 RCTs, and 13 systematic reviews). The use of PRISMA guidelines was explicitly declared in 54% of systematic reviews, CONSORT guidelines were referenced in 25% of RCTs and STROBE in 1.2% of observational studies. The use of CONSORT is required by all journals except FPMRS. PRISMA and STROBE are only compulsory in the journals GREEN, AJOG, and BJOG. The overall rate of explicit mentioning of RGs comparing urogynecology and general gynecology journals was 6.7% versus 7.1%, respectively. The explicit mentioning of RGs was on a relatively low level. A slightly higher adherence was recognized among general gynecology journals compared to urogynecology journals. Stronger efforts should be taken to further promote the use of RGs in urogynecology. © 2015 Wiley Periodicals, Inc.
Investigation of fast initialization of spacecraft bubble memory systems
NASA Technical Reports Server (NTRS)
Looney, K. T.; Nichols, C. D.; Hayes, P. J.
1984-01-01
Bubble domain technology offers significant improvement in reliability and functionality for spacecraft onboard memory applications. In considering potential memory systems organizations, minimization of power in high capacity bubble memory systems necessitates the activation of only the desired portions of the memory. In power strobing arbitrary memory segments, a capability of fast turn on is required. Bubble device architectures, which provide redundant loop coding in the bubble devices, limit the initialization speed. Alternate initialization techniques are investigated to overcome this design limitation. An initialization technique using a small amount of external storage is demonstrated.
Rooftop package unit diagnostician
Chassin, David P [Pasco, WA; Pratt, Robert G [Kennewick, WA; Reid, Larry Dean [Benton City, WA
2004-08-17
A diagnostic system for an HVAC system includes a number of sensors used to measure the operation of the HVAC system. Sensor readings are measured by timing the delay between when a strobe signal is sent to a sensor and when an interrupt signal from the sensor is received. A device driver used to measure the sensor readings stores the sensor readings in pseudo-character device files, which are universally accessible by different subsystems of the diagnostic system. Based on the readings from these sensors, this diagnostic system is able to determine the operational status of the HVAC system and if an economizer in the HVAC system is operating properly.
1988-12-01
round uses an AP/HTPB propellant in the projectile base to reduce base drag during flight . Subatmospheric burning rates, simulating operation at...the partial vacuum created at the projectile base in flight . The combustion gases escape the combustion chamber through an unchoked port in the...determination. Combustion of the sample was video recorded by a system with both synchronized electronic strobe and shutter. The camera captures 60 fields
NASA Technical Reports Server (NTRS)
Bell, James H.
2011-01-01
The luminescence lifetime technique was used to make pressure-sensitive paint (PSP) measurements on a 2.7% Common Research Model in the NASA Ames 11ft Transonic Wind Tunnel. PSP data were obtained on the upper and lower surfaces of the wing and horizontal tail, as well as one side of the fuselage. Data were taken for several model attitudes of interest at Mach numbers between 0.70 and 0.87. Image data were mapped onto a three-dimensional surface grid suitable both for comparison with CFD and for integration of pressures to determine loads. Luminescence lifetime measurements were made using strobed LED (light-emitting diode) lamps to illuminate the PSP and fast-framing interline transfer cameras to acquire the PSP emission.
1987-12-01
efficient * and smoothly run test and we are especially grateful for their dedication and support. Finally, Millard Thomas, an engineer with the Display...as a brightened spot ( marker ) on the electronic cursor. Range rings are provided for estimating the range of targets without using the range strobe...asked to express their reactions , for or against, specific TI characteristics, including style, content, format, delivery medium, and, in general, the
Stroboscope Controller for Imaging Helicopter Rotors
NASA Technical Reports Server (NTRS)
Jensen, Scott; Marmie, John; Mai, Nghia
2004-01-01
A versatile electronic timing-and-control unit, denoted a rotorcraft strobe controller, has been developed for use in controlling stroboscopes, lasers, video cameras, and other instruments for capturing still images of rotating machine parts especially helicopter rotors. This unit is designed to be compatible with a variety of sources of input shaftangle or timing signals and to be capable of generating a variety of output signals suitable for triggering instruments characterized by different input-signal specifications. It is also designed to be flexible and reconfigurable in that it can be modified and updated through changes in its control software, without need to change its hardware. Figure 1 is a block diagram of the rotorcraft strobe controller. The control processor is a high-density complementary metal oxide semiconductor, singlechip 8-bit microcontroller. It is connected to a 32K x 8 nonvolatile static random-access memory (RAM) module. Also connected to the control processor is a 32K 8 electrically programmable read-only-memory (EPROM) module, which is used to store the control software. Digital logic support circuitry is implemented in a field-programmable gate array (FPGA). A 240 x 128-dot, 40- character 16-line liquid-crystal display (LCD) module serves as a graphical user interface; the user provides input through a 16-key keypad mounted next to the LCD. A 12-bit digital-to-analog converter (DAC) generates a 0-to-10-V ramp output signal used as part of a rotor-blade monitoring system, while the control processor generates all the appropriate strobing signals. Optocouplers are used to isolate all input and output digital signals, and optoisolators are used to isolate all analog signals. The unit is designed to fit inside a 19-in. (.48-cm) rack-mount enclosure. Electronic components are mounted on a custom printed-circuit board (see Figure 2). Two power-conversion modules on the printedcircuit board convert AC power to +5 VDC and 15 VDC, respectively.
Braga, Luis H; Lorenzo, Armando J; Bagli, Darius J; Pippi Salle, Joao L; Caldamone, Anthony
2016-12-01
Observational studies, particularly case series, represent the majority of the current hypospadias research. As a result, this literature lacks standardization of surgical techniques, uniform definitions of hypospadias complications, and consistency of outcome reporting, which may make it difficult to compare results across studies. A modified version of the STROBE statement, containing 20 items, was presented at the International Pediatric Urology Task Force on Hypospadias meeting to assist with clear and transparent reporting of hypospadias studies. The adoption and implementation of this modified tool will allow investigators and health care providers to critically evaluate quality and identify bias within the literature. In addition this instrument will ensure consistency of reporting, improving objective comparisons between studies, unification of results, and development of evidence-based clinical guidelines. In this article, we have applied the modified STROBE statement to the hypospadias literature, aiming to create a guide on study reporting for pediatric urologists, and ultimately improve the quality of research in our field. We present itemized recommendations for adequate reporting of hypospadias studies and case series, ranging from drafting the abstract to addressing biases and potential sources of confounding. Included with each item is a brief explanation of its importance and potential effect on the study, as well as pertinent examples of hypospadias articles. A modified STROBE summary table containing 20 items is presented in (Supplementary Table 1). If properly conducted and reported, hypospadias studies have the potential to provide useful information to clinicians and surgeons. However, authors should recognize the inherent limitations of these observational studies, especially in the form of bias, which may introduce invalid data or limit generalizability. Thus, we expect that the use of this guiding tool will not only improve transparency of hypospadias reporting, but also improve its methodological quality, allowing proper comparison and interpretation of data across different institutions. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Poletto, Jamilynn B.; Cocherell, Dennis E.; Mussen, Timothy D.; Ercan, Ali; Bandeh, Hossein; Levent Kavvas, M.; Cech, Joseph J.; Fangue, Nann A.
2014-01-01
Water projects designed to extract fresh water for local urban, industrial and agricultural use throughout rivers and estuaries worldwide have contributed to the fragmentation and degradation of suitable habitat for native fishes. The number of water diversions located throughout the Sacramento–San Joaquin watershed in California's Central Valley exceeds 3300, and the majority of these are unscreened. Many anadromous fish species are susceptible to entrainment into these diversions, potentially impacting population numbers. In the laboratory, juvenile green sturgeon (Acipenser medirostris) have been shown to have high entrainment rates into unscreened diversions compared with those of other native California fish species, which may act as a significant source of mortality for this already-threatened species. Therefore, we tested the efficacy of a sensory deterrent (strobe light) and two structural pipe modifications (terminal pipe plate and upturned pipe configuration) in decreasing the entrainment of juvenile green sturgeon (mean mass ± SEM = 162.9 ± 4.0 g; mean fork length = 39.4 ± 0.3 cm) in a large (>500 kl) outdoor flume fitted with a water-diversion pipe 0.46 m in diameter. While the presence of the strobe light did not affect fish entrainment rates, the terminal pipe plate and upturned pipe modifications significantly decreased the proportion of fish entrained out of the total number tested relative to control conditions (0.13 ± 0.02 and 0.03 ± 0.02 vs. 0.44 ± 0.04, respectively). These data suggest that sensory deterrents using visual stimuli are not an effective means to reduce diversion pipe interactions for green sturgeon, but that structural alterations to diversions can successfully reduce entrainment for this species. Our results are informative for the development of effective management strategies to mitigate the impacts of water diversions on sturgeon populations and suggest that effective restoration strategies that balance agricultural needs with conservation programmes are possible. PMID:27293677
NASA Tech Briefs, November 2004
NASA Technical Reports Server (NTRS)
2004-01-01
Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.
Active listening for spatial orientation in a complex auditory scene.
Moss, Cynthia F; Bohn, Kari; Gilkenson, Hannah; Surlykke, Annemarie
2006-04-01
To successfully negotiate a complex environment, an animal must control the timing of motor behaviors in coordination with dynamic sensory information. Here, we report on adaptive temporal control of vocal-motor behavior in an echolocating bat, Eptesicus fuscus, as it captured tethered insects close to background vegetation. Recordings of the bat's sonar vocalizations were synchronized with high-speed video images that were used to reconstruct the bat's three-dimensional flight path and the positions of target and vegetation. When the bat encountered the difficult task of taking insects as close as 10-20 cm from the vegetation, its behavior changed significantly from that under open room conditions. Its success rate decreased by about 50%, its time to initiate interception increased by a factor of ten, and its high repetition rate "terminal buzz" decreased in duration by a factor of three. Under all conditions, the bat produced prominent sonar "strobe groups," clusters of echolocation pulses with stable intervals. In the final stages of insect capture, the bat produced strobe groups at a higher incidence when the insect was positioned near clutter. Strobe groups occurred at all phases of the wingbeat (and inferred respiration) cycle, challenging the hypothesis of strict synchronization between respiration and sound production in echolocating bats. The results of this study provide a clear demonstration of temporal vocal-motor control that directly impacts the signals used for perception.
Active Listening for Spatial Orientation in a Complex Auditory Scene
Bohn, Kari; Gilkenson, Hannah; Surlykke, Annemarie
2006-01-01
To successfully negotiate a complex environment, an animal must control the timing of motor behaviors in coordination with dynamic sensory information. Here, we report on adaptive temporal control of vocal–motor behavior in an echolocating bat, Eptesicus fuscus, as it captured tethered insects close to background vegetation. Recordings of the bat's sonar vocalizations were synchronized with high-speed video images that were used to reconstruct the bat's three-dimensional flight path and the positions of target and vegetation. When the bat encountered the difficult task of taking insects as close as 10–20 cm from the vegetation, its behavior changed significantly from that under open room conditions. Its success rate decreased by about 50%, its time to initiate interception increased by a factor of ten, and its high repetition rate “terminal buzz” decreased in duration by a factor of three. Under all conditions, the bat produced prominent sonar “strobe groups,” clusters of echolocation pulses with stable intervals. In the final stages of insect capture, the bat produced strobe groups at a higher incidence when the insect was positioned near clutter. Strobe groups occurred at all phases of the wingbeat (and inferred respiration) cycle, challenging the hypothesis of strict synchronization between respiration and sound production in echolocating bats. The results of this study provide a clear demonstration of temporal vocal–motor control that directly impacts the signals used for perception. PMID:16509770
Weaknesses in the reporting of cross-sectional studies according to the STROBE statement
Malaga, German; Miranda, Jaime
2015-01-01
Introduction: The inadequate reporting of cross-sectional studies, as in the case of the prevalence of metabolic syndrome, could cause problems in the synthesis of new evidence and lead to errors in the formulation of public policies. Objective: To evaluate the reporting quality of the articles regarding metabolic syndrome prevalence in Peruvian adults using the STROBE recommendations. Methods: We conducted a thorough literature search with the terms "Metabolic Syndrome", "Sindrome Metabolico" and "Peru" in MEDLINE/PubMed, LILACS, SciELO, LIPECS and BVS-Peru until December 2014. We selected those who were population-based observational studies with randomized sampling that reported prevalence of metabolic syndrome in adults aged 18 or more of both sexes. Information was analysed through the STROBE score per item and recommendation. Results: Seventeen articles were included in this study. All articles met the recommendations related to the report of the study's rationale, design, and provision of summary measures. The recommendations with the lowest scores were those related to the sensitivity analysis (8%, n= 1/17), participant flowchart (18%, n= 3/17), missing data analysis (24%, n= 4/17), and number of participants in each study phase (24%, n= 4/17). Conclusion: Cross-sectional studies regarding the prevalence of metabolic syndrome in peruvian adults have an inadequate reporting on the methods and results sections. We identified a clear need to improve the quality of such studies. PMID:26848197
Tapia, Jose Carlos; Ruiz, Eloy F; Ponce, Oscar J; Malaga, German; Miranda, Jaime
2015-12-30
The inadequate reporting of cross-sectional studies, as in the case of the prevalence of metabolic syndrome, could cause problems in the synthesis of new evidence and lead to errors in the formulation of public policies. To evaluate the reporting quality of the articles regarding metabolic syndrome prevalence in Peruvian adults using the STROBE recommendations. We conducted a thorough literature search with the terms "Metabolic Syndrome", "Sindrome Metabolico" and "Peru" in MEDLINE/PubMed, LILACS, SciELO, LIPECS and BVS-Peru until December 2014. We selected those who were population-based observational studies with randomized sampling that reported prevalence of metabolic syndrome in adults aged 18 or more of both sexes. Information was analysed through the STROBE score per item and recommendation. Seventeen articles were included in this study. All articles met the recommendations related to the report of the study's rationale, design, and provision of summary measures. The recommendations with the lowest scores were those related to the sensitivity analysis (8%, n= 1/17), participant flowchart (18%, n= 3/17), missing data analysis (24%, n= 4/17), and number of participants in each study phase (24%, n= 4/17). Cross-sectional studies regarding the prevalence of metabolic syndrome in peruvian adults have an inadequate reporting on the methods and results sections. We identified a clear need to improve the quality of such studies.
Capturing Reality at Centre Block
NASA Astrophysics Data System (ADS)
Boulanger, C.; Ouimet, C.; Yeomans, N.
2017-08-01
The Centre Block of Canada's Parliament buildings, National Historic Site of Canada is set to undergo a major rehabilitation project that will take approximately 10 years to complete. In preparation for this work, Heritage Conservation Services (HCS) of Public Services and Procurement Canada has been completing heritage documentation of the entire site which includes laser scanning of all interior rooms and accessible confined spaces such as attics and other similar areas. Other documentation completed includes detailed photogrammetric documentation of rooms and areas of high heritage value. Some of these high heritage value spaces present certain challenges such as accessibility due to the height and the size of the spaces. Another challenge is the poor lighting conditions, requiring the use of flash or strobe lighting to either compliment or completely eliminate the available ambient lighting. All the spaces captured at this higher level of detail were also captured with laser scanning. This allowed the team to validate the information and conduct a quality review of the photogrammetric data. As a result of this exercise, the team realized that in most, if not all cases, the photogrammetric data was more detailed and at a higher quality then the terrestrial laser scanning data. The purpose and motivation of this paper is to present these findings, as well provide the advantages and disadvantages of the two methods and data sets.
Buchanan, Ryan; Khakoo, Salim I; Coad, Jonathan; Grellier, Leonie; Parkes, Julie
2017-07-11
New, more effective and better-tolerated therapies for hepatitis C (HCV) have made the elimination of HCV a feasible objective. However, for this to be achieved, it is necessary to have a detailed understanding of HCV epidemiology in people who inject drugs (PWID). Respondent-driven sampling (RDS) can provide prevalence estimates in hidden populations such as PWID. The aims of this systematic review are to identify published studies that use RDS in PWID to measure the prevalence of HCV, and compare each study against the STROBE-RDS checklist to assess their sensitivity to the theoretical assumptions underlying RDS. Searches were undertaken in accordance with PRISMA systematic review guidelines. Included studies were English language publications in peer-reviewed journals, which reported the use of RDS to recruit PWID to an HCV bio-behavioural survey. Data was extracted under three headings: (1) survey overview, (2) survey outcomes, and (3) reporting against selected STROBE-RDS criteria. Thirty-one studies met the inclusion criteria. They varied in scale (range 1-15 survey sites) and the sample sizes achieved (range 81-1000 per survey site) but were consistent in describing the use of standard RDS methods including: seeds, coupons and recruitment incentives. Twenty-seven studies (87%) either calculated or reported the intention to calculate population prevalence estimates for HCV and two used RDS data to calculate the total population size of PWID. Detailed operational and analytical procedures and reporting against selected criteria from the STROBE-RDS checklist varied between studies. There were widespread indications that sampling did not meet the assumptions underlying RDS, which led to two studies being unable to report an estimated HCV population prevalence in at least one survey location. RDS can be used to estimate a population prevalence of HCV in PWID and estimate the PWID population size. Accordingly, as a single instrument, it is a useful tool for guiding HCV elimination. However, future studies should report the operational conduct of each survey in accordance with the STROBE-RDS checklist to indicate sensitivity to the theoretical assumptions underlying the method. PROSPERO CRD42015019245.
Stroboscopic Vision as a Treatment for Space Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Somers, Jeffrey T.; Ford, George; Krnavek, Jody M.
2007-01-01
Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill Jones we have evaluated stroboscopic vision as a method of preventing motion sickness. Given that the data presented by professor Melvill Jones were primarily post hoc results following a study not designed to investigate motion sickness, it is unclear how motion sickness results were actually determined. Building on these original results, we undertook a three part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness using: (1) visual field reversal, (2) Reading while riding in a car (with or without external vision present), and (3) making large pitch head movements during parabolic flight.
Vocal symptoms in Parkinson disease treated with levodopa. A case report.
Schley, W S; Fenton, E; Niimi, S
1982-01-01
This is a report of a patient with unusually severe hoarseness in the absence of vocal fold pathology demonstrating Parkinson disease as one of the neurological diseases in which vocal symptoms occur. Although it is classifiably a severe, progressive, degenerative disorder, the popularity of pharmacotherapy for Parkinson disease during the past decade has resulted in improved functionality for an undetermined course of time in most patients. The classically described deterioration of speech ad voice may develop in a variant manner difficult to distinguish as disease-related, as this case report illustrates. An explanation of the hoarseness based on dyssynchronous vocal fold motion related to the disease is suggested by the acoustic methods (spectrography, waveform analysis) used in this study, and supported by strobe light laryngoscopy. This conclusion is important because of the extremely high incidences of varying degrees of hoarseness reported in recent studies of Parkinson disease.
The limits and motivating potential of sensory stimuli as reinforcers for autistic children.
Ferrari, M; Harris, S L
1981-01-01
This study investigated the reinforcing properties, limits, and motivating potentials of sensory stimuli with autistic children. In the first phase of the study, four intellectually retarded autistic children were exposed to three different types of sensory stimulation (vibration, music, and strobe light) as well as edible and social reinforcers for ten-second intervals contingent upon six simple bar pressing responses. In the second phase, the same events were used as reinforcers for correct responses in learning object labels. The results indicated that: (a) sensory stimuli can be used effectively as reinforcers to maintain high, durable rates of responding in a simple pressing task; (b) ranked preferences for sensory stimuli revealed a unique configuration of responding for each child; and (c) sensory stimuli have motivating potentials comparable to those of the traditional food and social reinforcers even when training receptive language tasks.
Manchester Coding Option for SpaceWire: Providing Choices for System Level Design
NASA Technical Reports Server (NTRS)
Rakow, Glenn; Kisin, Alex
2014-01-01
This paper proposes an optional coding scheme for SpaceWire in lieu of the current Data Strobe scheme for three reasons. First reason is to provide a straightforward method for electrical isolation of the interface; secondly to provide ability to reduce the mass and bend radius of the SpaceWire cable; and thirdly to provide a means for a common physical layer over which multiple spacecraft onboard data link protocols could operate for a wide range of data rates. The intent is to accomplish these goals without significant change to existing SpaceWire design investments. The ability to optionally use Manchester coding in place of the current Data Strobe coding provides the ability to DC balanced the signal transitions unlike the SpaceWire Data Strobe coding; and therefore the ability to isolate the electrical interface without concern. Additionally, because the Manchester code has the clock and data encoded on the same signal, the number of wires of the existing SpaceWire cable could be optionally reduced by 50. This reduction could be an important consideration for many users of SpaceWire as indicated by the already existing effort underway by the SpaceWire working group to reduce the cable mass and bend radius by elimination of shields. However, reducing the signal count by half would provide even greater gains. It is proposed to restrict the data rate for the optional Manchester coding to a fixed data rate of 10 Megabits per second (Mbps) in order to make the necessary changes simple and still able to run in current radiation tolerant Field Programmable Gate Arrays (FPGAs). Even with this constraint, 10 Mbps will meet many applications where SpaceWire is used. These include command and control applications and many instruments applications with have moderate data rate. For most NASA flight implementations, SpaceWire designs are in rad-tolerant FPGAs, and the desire to preserve the heritage design investment is important for cost and risk considerations. The Manchester coding option can be accommodated in existing designs with only changes to the FPGA.
Vision training methods for sports concussion mitigation and management.
Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon
2015-05-05
There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.
Automatic detection, tracking and sensor integration
NASA Astrophysics Data System (ADS)
Trunk, G. V.
1988-06-01
This report surveys the state of the art of automatic detection, tracking, and sensor integration. In the area of detection, various noncoherent integrators such as the moving window integrator, feedback integrator, two-pole filter, binary integrator, and batch processor are discussed. Next, the three techniques for controlling false alarms, adapting thresholds, nonparametric detectors, and clutter maps are presented. In the area of tracking, a general outline is given of a track-while-scan system, and then a discussion is presented of the file system, contact-entry logic, coordinate systems, tracking filters, maneuver-following logic, tracking initiating, track-drop logic, and correlation procedures. Finally, in the area of multisensor integration the problems of colocated-radar integration, multisite-radar integration, radar-IFF integration, and radar-DF bearing strobe integration are treated.
Sex-specific impact of prenatal stress on growth and reproductive parameters of guinea pigs.
Schöpper, Hanna; Klaus, Teresa; Palme, Rupert; Ruf, Thomas; Huber, Susanne
2012-12-01
Body condition and reproductive maturation are parameters of reproductive success that are influenced by sexual hormones rising in the circulation during the time of puberty. Various endocrine systems can be programmed by conditions experienced during early life. Stress for instance is supposed to be capable of influencing fetal development, leading to adjustments of offspring's later physiology. We examined whether prenatal stress (induced by exposure to strobe light) during early- to mid-gestation was capable of affecting later reproductive parameters in guinea pigs (Cavia aperea f. porcellus). Therefore, we measured the levels of testosterone and progesterone from the age of day 12-124 in prenatally stressed (PS, n = 20) and unaffected control animals (n = 24). Furthermore, we determined the timing of puberty and growth. Body weight development revealed significantly faster growth in PS females compared to control animals. The onset of first estrus was slightly earlier in PS females, however not significantly so. Cycle lengths and levels of progesterone differed between groups over the course of time with higher progesterone levels and more constant cycles among PS females compared to control females who displayed marked differences between first and subsequent cycles. Levels of testosterone did not differ between groups. We conclude that prenatal stress accelerates growth and maturity in females, but not in males.
NASA Astrophysics Data System (ADS)
2013-11-01
WE RECOMMEND LabQuest 2 New logger now includes mobile data sharing Rubens' Tube Sturdy Rubens' tube ramps up the beat Ripple Strobe Tank Portable ripple tank makes waves in and out of the lab God and the Atom Expertly told story of the influence of atomism Maxwell's Equations Video stands the test of time Exploring Quantum Physics Through Hands-on Projects Mixture of theory and experiment hits the spot WORTH A LOOK Magnificent Principia, Exploring Isaac Newton's Masterpiece The tricky task of summarizing Newton's iconic work Talking Science: Language, Learning, and Values Interesting book tackles communication in the classroom WEB WATCH Interactive website plans a trip to Mars ... documentary peers into telescopes ... films consider the density of water
The STROBE-X Science Case: An Overview
NASA Astrophysics Data System (ADS)
Maccarone, Thomas J.; STROBE-X consortium
2018-01-01
STROBE-X is a proposed NASA Probe class mission aimed at the extremes of high throughput X-ray astronomy, making use of an 8 m^2 total collecting area, CCD-quality spectral resolution, and a state-of-the art wide field monitor with both very large instantaneous sky coverage (ideal for follow-up of LIGO events) and good intrinsic spectral and time resolution. The core goals are time domain astrophysics and high count spectroscopy. Its capabilities span a broad range of topics, including those traditional to X-ray timing missions, like understanding the equation of states of neutron stars, and the spin distributions and masses of neutron stars and stellar mass and supermassive black holes, and the rates, and detailed properties, of a variety of classes of X-ray transients; and also topics not traditionally studied by such missions such as the spectra of supernova remnants, comets and of clusters and groups of galaxies.
[The ultra-rapid cinematography of the larynx, its contributions in speech pathology].
Chevaillier, G; Sauvaget, E; Herman, P; Tran Ba Huy, P
2010-01-01
The development in the medical field of high speed cinematography and its dissemination in the field of speech pathology will probably change the way we view the larynx and diagnose its disorders. So far only the stroboscope could inform us about the appearance of vocal cord vibration but with certain limitations. Indeed the wave motion of the vocal cords is really only apparent motion. It is made possible through the phenomenon of retinal persistence of images and light intermittent vocal folds set to the frequency of the voice and out of phase by a few Hertz. This technique has several disadvantages: The need for the voice to trigger the strobe light; a low number of frames per second (25 fps) recorded; frame loss for the period between unlit two flashes; limitation in the study of the upper voice spectrum (gearing). The ultra-rapid cinematography brings a big difference in design since the digital recording can shoot up to 4000 frames per second with permanent lighting of the larynx. The slow reading of short sequences permits us to view the actual movement of vibrating structures, and to analyze the behavior of the vibrator during the transitional phases of the attack, depreciation and termination of sound. The footage in high resolution permits a detailed analysis of the movements of opening and closing of the vocal cords in phonation and respiration, and the diagnosis of lesions.
High-precision gauging of metal rings
NASA Astrophysics Data System (ADS)
Carlin, Mats; Lillekjendlie, Bjorn
1994-11-01
Raufoss AS designs and produces air brake fittings for trucks and buses on the international market. One of the critical components in the fittings is a small, circular metal ring, which is going through 100% dimension control. This article describes a low-price, high accuracy solution developed at SINTEF Instrumentation based on image metrology and a subpixel resolution algorithm. The measurement system consists of a PC-plugg-in transputer video board, a CCD camera, telecentric optics and a machine vision strobe. We describe the measurement technique in some detail, as well as the robust statistical techniques found to be essential in the real life environment.
Misclassification of Case-Control Studies in Neurosurgery and Proposed Solutions.
Esene, Ignatius Ngene; Mbuagbaw, Lawrence; Dechambenoit, Gilbert; Reda, Wael; Kalangu, Kazadi K
2018-04-01
Case-control studies (CCS) and cohort studies (CS) are common research designs in neurosurgery. But the term case-control study is frequently misused in the neurosurgical literature, with many articles reported as CCS, even although their methodology does not respect the basic components of a CCS. We sought to estimate the extent of these discrepancies in neurosurgical literature, explore factors contributing to mislabeling, and shed some light on study design reporting. We identified 31 top-ranking pure neurosurgical journals and searched them for articles reported as CCS, either in the title or in the abstract. The articles were read to determine if they really were CCS according to STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Article assessment was conducted in duplicate (agreement [κ statistics] = 99.82%). Two hundred and twenty-four articles met our inclusion criteria, 133 of which (59.38%) correctly labeled the case-control design, whereas 91 (40.62%) misclassified this study design. Cohort studies (CS) were the most common design mislabeled as case-control studies in 76 articles (33.93%), 57 of which (25.45%) were retrospective CS. The mislabeling of CCS impairs the appropriate indexing, classification, and sorting of evidence. Mislabeling CS for CCS leads to a downgrading of evidence as CS represent the highest level of evidence for observational studies. Odds ratios instead of relative risk are reported for these studies, resulting in a distortion of the measurement of the effect size, compounded when these are summarized in systematic reviews and pooled in meta-analyses. Many studies reported as CCS are not true CCS. Reporting guidelines should include items that ensure that studies are labeled correctly. STROBE guidelines should be implemented in assessment of observational studies. Researchers in neurosurgery need better training in research methods and terminology. We also recommend accrued vigilance from reviewers and editors. Copyright © 2018 Elsevier Inc. All rights reserved.
Dynamic photoelasticity by TDI imaging
NASA Astrophysics Data System (ADS)
Asundi, Anand K.; Sajan, M. R.
2001-06-01
High speed photographic system like the image rotation camera, the Cranz Schardin camera and the drum camera are typically used for the recording and visualization of dynamic events in stress analysis, fluid mechanics, etc. All these systems are fairly expensive and generally not simple to use. Furthermore they are all based on photographic film recording system requiring time consuming and tedious wet processing of the films. Digital cameras are replacing the conventional cameras, to certain extent in static experiments. Recently, there is lots of interest in development and modifying CCD architectures and recording arrangements for dynamic scenes analysis. Herein we report the use of a CCD camera operating in the Time Delay and Integration mode for digitally recording dynamic photoelastic stress patterns. Applications in strobe and streak photoelastic pattern recording and system limitations will be explained in the paper.
Multiradar tracking for theater missile defense
NASA Astrophysics Data System (ADS)
Sviestins, Egils
1995-09-01
A prototype system for tracking tactical ballistic missiles using multiple radars has been developed. The tracking is based on measurement level fusion (`true' multi-radar) tracking. Strobes from passive sensors can also be used. We describe various features of the system with some emphasis on the filtering technique. This is based on the Interacting Multiple Model framework where the states are Free Flight, Drag, Boost, and Auxiliary. Measurement error modeling includes the signal to noise ratio dependence; outliers and miscorrelations are handled in the same way. The launch point is calculated within one minute from the detection of the missile. The impact point, and its uncertainty region, is calculated continually by extrapolating the track state vector using the equations of planetary motion.
The reporting of observational research studies in dermatology journals: a literature-based study.
Langan, Sinéad; Schmitt, Jochen; Coenraads, Pieter-Jan; Svensson, Ake; von Elm, Erik; Williams, Hywel
2010-05-01
To assess the quality of reporting in observational studies in dermatology. Five dermatology journals-the Archives of Dermatology, the British Journal of Dermatology, the Journal of the American Academy of Dermatology, the Journal of Investigative Dermatology, and Acta Dermato-Venereologica. Cohort, case-control, and cross-sectional studies published as original articles during the period January 2005 through December 2007. Studies were identified with a literature search of PubMed combining the journal title and the term epidemiological studies (free text) and by hand searching all of the issues of each journal to identify relevant articles. All articles were extracted by 2 reviewers independently using standardized checklists based on the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) recommendations. The number and proportion of reported STROBE items were analyzed for each article. The proportion of studies with good reporting for each item was also assessed. A total of 138 articles were included and analyzed. Reporting quality was very mixed. Key areas that were infrequently reported included sample size calculations (n = 10 [7%]), missing data (n = 8 [6%]), losses to follow-up (n = 17 [12%]), and statistical methods (n = 19 [14%]). Only 13 studies (9%) explained the role of funders in the research. The quality of reporting was similar across study designs for "critical" questions with the exception of reporting of participant details, which was better reported in cohort studies (96%) compared with cross-sectional (80%) and case-control (70%) studies. It is difficult to judge the quality of dermatological research unless it is reported well. This study has identified a clear need to improve the quality of reporting of observational studies in dermatology. We recommend that dermatology journals adopt the STROBE criteria.
Issues of reporting in observational studies in veterinary medicine.
Sargeant, Jan M; O'Connor, Annette M
2014-02-15
Observational studies are common in veterinary medicine; the results may be used to inform decision-making, future research, or as inputs to systematic reviews or risk assessment. To be of use, the results must be published, all of the outcomes that were assessed must be included in the publication, and the research (methods and results) must be reported in sufficient detail that the reader can evaluate the internal and external validity. In human healthcare, concerns about the completeness of reporting - and evidence that poor reporting is associated with study results - have led to the creation of reporting guidelines; these include the STROBE statement for observational studies. There is evidence from a limited body of research that there also are reporting inadequacies in veterinary observational studies. There are differences between human and veterinary observational studies that might be relevant to recommendations for reporting. Such differences include: the use of observational studies in animal populations for simultaneously estimating disease frequency and risk-factor identification; the distinction between the animal owners who consent to participate and the animals that are the study subjects; and the complexity of organizational levels inherent in animal research (in particular, for studies in livestock species). In veterinary medicine, it is common to have clustering within outcomes (due to animal grouping) and clustering of predictor variables. We argue that there is a compelling need for the scientific community involved in veterinary observational studies to use the STROBE statement, use an amended version of STROBE, or to develop and use reporting guidelines that are specific to veterinary medicine to improve reporting of these studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Vision Training Methods for Sports Concussion Mitigation and Management
Clark, Joseph F.; Colosimo, Angelo; Ellis, James K.; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon
2015-01-01
There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock’s string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention. PMID:25992878
Characterization of a 512x512-pixel 8-output full-frame CCD for high-speed imaging
NASA Astrophysics Data System (ADS)
Graeve, Thorsten; Dereniak, Eustace L.
1993-01-01
The characterization of a 512 by 512 pixel, eight-output full frame CCD manufactured by English Electric Valve under part number CCD13 is discussed. This device is a high- resolution Silicon-based array designed for visible imaging applications at readout periods as low as two milliseconds. The characterization of the device includes mean-variance analysis to determine read noise and dynamic range, as well as charge transfer efficiency, MTF, and quantum efficiency measurements. Dark current and non-uniformity issues on a pixel-to-pixel basis and between individual outputs are also examined. The characterization of the device is restricted by hardware limitations to a one MHz pixel rate, corresponding to a 40 ms readout time. However, subsections of the device have been operated at up to an equivalent 100 frames per second. To maximize the frame rate, the CCD is illuminated by a synchronized strobe flash in between frame readouts. The effects of the strobe illumination on the imagery obtained from the device is discussed.
Kelly, P Adam; Haidet, Paul; Schneider, Virginia; Searle, Nancy; Seidel, Charles L; Richards, Boyd F
2005-01-01
Having recently introduced team learning into the preclinical medical curriculum, evidence of the relative impact of this instructional method on in-class learner engagement was sought. To compare patterns of engagement behaviors among learners in class sessions across 3 distinct instructional methods: lecture, problem-based learning (PBL), and team learning. Trained observers used the STROBE classroom observation tool to measure learner engagement in 7 lecture, 4 PBL, and 3 team learning classrooms over a 12-month period. Proportions of different types of engagement behaviors were compared using chi-square. In PBL and team learning, the amount of learner-to-learner engagement was similar and much greater than in lecture, where most engagement was of the learner-to-instructor and self-engagement types. Also, learner-to-instructor engagement appeared greater in team learning than in PBL. Observed engagement behaviors confirm the potential of team learning to foster engagement similar to PBL, but with greater faculty input.
NASA Astrophysics Data System (ADS)
Pattini, F.; Porzio Giusto, P.
The design criteria and performance of the master clock (MCK) generator and the unique word (UW) detector are examined. A narrow band phase lock loop is used for the onboard MCK generator and it is implemented with an all-digital scheme that employs a D-type flip flop as the phase detector. The performance of the MCK generator is analyzed with a computer program which considers phase offset of the digital phase comparator. The characteristics and capabilities of the UW detector which provides strobe signals for the MCK generator and synchronization signals for the onboard switching matrix are described.
Illumination design for semiconductor backlight inspection and application extensions
NASA Astrophysics Data System (ADS)
Zhou, Wei; Rutherford, Todd; Hart, Darcy
2013-09-01
High speed strobe based illumination scheme is one of the most critical factors for high throughput semiconductor defect inspection applications. HB LEDs are always the first and best options for such applications due to numerous unique advantages such as excellent spatial and temporal stability, fast responding time, large and linear intensity dynamic range and no heat issue for the extremely low duty cycle applications. For some applications where a large area is required to be illuminated simultaneously, it remains a great challenge to efficiently package a large amount of HB-LEDs in a highly confined 3D space, to generate a seamless illuminated area with high luminance efficiency and spatial uniformity. A novel 3D structured collimation lens is presented in this paper. The non-circular edge shape reduces the intensity drop at the channel boundaries, while the secondary curvatures on the top of the collimator lens efficiently guides the light into desired angular space. The number of the edges and the radius of the top surface curvature are control parameters for the system level performance and the manufacture cost trade-off. The proposed 3D structured LED collimation lens also maintains the benefits of traditional LED collimation lens such as coupling efficiency and mold manufacture capability. The applications can be extended into other non-illumination area like parallelism measurement and solar panel concentrator etc.
Laser line scan underwater imaging by complementary metal-oxide-semiconductor camera
NASA Astrophysics Data System (ADS)
He, Zhiyi; Luo, Meixing; Song, Xiyu; Wang, Dundong; He, Ning
2017-12-01
This work employs the complementary metal-oxide-semiconductor (CMOS) camera to acquire images in a scanning manner for laser line scan (LLS) underwater imaging to alleviate backscatter impact of seawater. Two operating features of the CMOS camera, namely the region of interest (ROI) and rolling shutter, can be utilized to perform image scan without the difficulty of translating the receiver above the target as the traditional LLS imaging systems have. By the dynamically reconfigurable ROI of an industrial CMOS camera, we evenly divided the image into five subareas along the pixel rows and then scanned them by changing the ROI region automatically under the synchronous illumination by the fun beams of the lasers. Another scanning method was explored by the rolling shutter operation of the CMOS camera. The fun beam lasers were turned on/off to illuminate the narrow zones on the target in a good correspondence to the exposure lines during the rolling procedure of the camera's electronic shutter. The frame synchronization between the image scan and the laser beam sweep may be achieved by either the strobe lighting output pulse or the external triggering pulse of the industrial camera. Comparison between the scanning and nonscanning images shows that contrast of the underwater image can be improved by our LLS imaging techniques, with higher stability and feasibility than the mechanically controlled scanning method.
Bubble memory module for spacecraft application
NASA Technical Reports Server (NTRS)
Hayes, P. J.; Looney, K. T.; Nichols, C. D.
1985-01-01
Bubble domain technology offers an all-solid-state alternative for data storage in onboard data systems. A versatile modular bubble memory concept was developed. The key module is the bubble memory module which contains all of the storage devices and circuitry for accessing these devices. This report documents the bubble memory module design and preliminary hardware designs aimed at memory module functional demonstration with available commercial bubble devices. The system architecture provides simultaneous operation of bubble devices to attain high data rates. Banks of bubble devices are accessed by a given bubble controller to minimize controller parts. A power strobing technique is discussed which could minimize the average system power dissipation. A fast initialization method using EEPROM (electrically erasable, programmable read-only memory) devices promotes fast access. Noise and crosstalk problems and implementations to minimize these are discussed. Flight memory systems which incorporate the concepts and techniques of this work could now be developed for applications.
Space Tug Avionics Definition Study. Volume 5: Cost and Programmatics
NASA Technical Reports Server (NTRS)
1975-01-01
The baseline avionics system features a central digital computer that integrates the functions of all the space tug subsystems by means of a redundant digital data bus. The central computer consists of dual central processor units, dual input/output processors, and a fault tolerant memory, utilizing internal redundancy and error checking. Three electronically steerable phased arrays provide downlink transmission from any tug attitude directly to ground or via TDRS. Six laser gyros and six accelerometers in a dodecahedron configuration make up the inertial measurement unit. Both a scanning laser radar and a TV system, employing strobe lamps, are required as acquisition and docking sensors. Primary dc power at a nominal 28 volts is supplied from dual lightweight, thermally integrated fuel cells which operate from propellant grade reactants out of the main tanks.
A Countermeasure for Space Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Somers, J. T.; Leigh, R. J.; Jones, G. Melvill
2006-01-01
Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness.
Theodor D. Leininger; W.E. Winner; S.A. Alexander
1990-01-01
A survey was conducted in the Coweeta Basin, Macon County, North Carolina, to determine the incidence of root diseases and their relatedness to ozone symptomatology in two eastern white pine (Pinus strobes) plantations. Heterobasidion annosum was isolated from
70. VIEW OF UNIT 2 THROUGH ACCESS DOOR, LOOKING DOWN ...
70. VIEW OF UNIT 2 THROUGH ACCESS DOOR, LOOKING DOWN AT MAIN SHAFT. NOTE WELDER'S SIGNATURE IN SHADOWS IN UPPER LEFT CORNER AND PHOTOGRAPHER'S STROBE POWER CABLE IN LOWER RIGHT CORNER. ORIENTATION OF CAMERA IS FACING LEFT BANK, PERPENDICULAR TO RIVER FLOW - Swan Falls Dam, Snake River, Kuna, Ada County, ID
STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Milliseconds to Years
NASA Technical Reports Server (NTRS)
Wilson-Hodge, Colleen A.; Ray, P. S.; Maccarone, T; Chakrabarty, D.; Gendreau, K.; Arzoumanian, Z.; Jenke, P.; Ballantyne, D.; Bozzo, E.; Brandt, S.;
2018-01-01
We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER [1], with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT [2], to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis. For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained
STROBE-X: X-Ray Timing Spectroscopy on Dynamical Timescales from Microseconds to Years
NASA Technical Reports Server (NTRS)
Wilson-Hodge, Colleen A.; Ray, P. S.; Gendreau, K.; Arzoumanian, Z.; Chakrabarty, D.; Remillard, R.; Feroci, M.; Maccarone, T.; Wood, K.; Jenke, P.
2017-01-01
We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis.For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained.
STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Microseconds to Years
NASA Astrophysics Data System (ADS)
Wilson-Hodge, Colleen A.; Ray, Paul S.; Gendreau, Keith; Chakrabarty, Deepto; Feroci, Marco; Maccarone, Thomas J.; Arzoumanian, Zaven; Remillard, Ronald A.; Wood, Kent; Griffith, Christopher; Jenke, Peter
2017-08-01
We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with ~20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis.For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained.
Stabilizing effect of elasticity on the inertial instability of submerged viscoelastic liquid jets
NASA Astrophysics Data System (ADS)
Keshavarz, Bavand; McKinley, Gareth
2017-11-01
The stability of submerged Newtonian and viscoelastic liquid jets is studied experimentally using flow visualization. Precise control of the amplitude and frequency of the imposed linear perturbations is achieved through a piezoelectric actuator attached to the nozzle. By illuminating the jet with a strobe light driven at a frequency slightly less than the frequency of the perturbation we slow down the apparent motion by large factors ( 100 , 000) and capture the phenomena with high temporal and spatial resolution. Newtonian liquid jets become unstable at moderate Reynolds numbers (Rej 150) and sinuous or varicose patterns emerge and grow in amplitude. As the jet moves downstream, the varicose waves gradually pile up in the sinuous ones due to the difference in their corresponding wave speeds, leading to a unique chevron-like morphology. Experiments with model viscoelastic polymer solutions show that this inertial instability is fully stabilized sufficiently large levels of elasticity. We compare our experimental results with the theoretical predictions of an elastic Rayleigh equation for an axisymmetric jet and show that the presence of streamline tension is indeed the stabilizing effect for inertioelastic jets.
NASA Astrophysics Data System (ADS)
Chang, Jiaqing; Liu, Yaxin; Huang, Bo
2017-07-01
In inkjet applications, it is normal to search for an optimal drive waveform when dispensing a fresh fluid or adjusting a newly fabricated print-head. To test trial waveforms with different dwell times, a camera and a strobe light were used to image the protruding or retracting liquid tongues without ejecting any droplets. An edge detection method was used to calculate the lengths of the liquid tongues to draw the meniscus movement curves. The meniscus movement is determined by the time-domain response of the acoustic pressure at the nozzle of the print-head. Starting at the inverse piezoelectric effect, a mathematical model which considers the liquid viscosity in acoustic propagation is constructed to study the acoustic pressure response at the nozzle of the print-head. The liquid viscosity retards the propagation speed and dampens the harmonic amplitude. The pressure response, which is the combined effect of the acoustic pressures generated during the rising time and the falling time and after their propagations and reflections, explains the meniscus movements well. Finally, the optimal dwell time for droplet ejections is discussed.
Mixing Characteristics of Coaxial Injectors at High Gas to Liquid Momentum Ratios
NASA Technical Reports Server (NTRS)
Strakey, P. A.; Talley, D. G.; Hutt, J. J.
1999-01-01
A study of the spray of a swirl coaxial gas-liquid injector operating at high gas to liquid momentum ratios is reported. Mixing and droplet size characteristics of the swirl injector are also compared to a shear coaxial injector, currently being used in the Space Shuttle Main Engine fuel preburner. The injectors were tested at elevated chamber pressures using water as a LOX simulant and nitrogen and helium as gaseous hydrogen simulants. The elevated chamber pressure allowed for matching of several of the preburner injector conditions including; gas to liquid momentum ratio, density ratio and Mach number. Diagnostic techniques used to characterize the spray included; strobe back-light imaging, laser sheet spray imaging, mechanical patternation, and a phase Doppler interferometry. Results thus far indicate that the radial spreading of the swirl coaxial spray is much less than was reported in previous studies of swirl injectors operating at atmospheric back-pressure. The swirl coaxial spray does, however, exhibit a smaller overall droplet size which may be interpreted as an increase in local mixing.
Troubleshooting Microcomputers. A Technical Guide for Polk County Schools.
ERIC Educational Resources Information Center
Black, B. R.; And Others
This guide was started in 1986 as an effort to pull together a collection of several computer guides that had been written over the previous several years to assist schools in making simple computer repairs. The first of six sections contains general tips and hints, including sections on tool requirements, strobe disk speed adjustment, static…
Early evidence of weevil resistance in some clones and hybrids of white pine
Peter W. Garrett
1970-01-01
White pine species and hybrids are being tested for inherent resistance to the white-pine weevil. First-year results offer hopes of finding or developing resistance in this group. Pinus monticola had a low level of weeviling, while the hybrid between P. strobes X P. wallichiana was heavily weeviled. There is...
[Clinical study on vocal cords spontaneous rehabilitation after CO2 laser surgery].
Zhang, Qingxiang; Hu, Huiying; Sun, Guoyan; Yu, Zhenkun
2014-10-01
To study the spontaneous rehabilitation and phonation quality of vocal cords after different types of CO2 laser microsurgery. Surgical procedures based on Remacle system Type I, Type II, Type III, Type IV and Type V a respectively. Three hundred and fifteen cases with hoarseness based on strobe laryngoscopy results were prospectively assigned to different group according to vocal lesions apperence,vocal vibration and imaging of larynx CT/MRI. Each group holded 63 cases. The investigation included the vocal cords morphological features,the patients' subjective feelings and objective results of vocal cords. There are no severe complications for all patients in perioperative period. Vocal scar found in Type I ,1 case; Type II, 9 cases ;Type III, 47 cases; Type IV, 61 cases and Type Va 63 cases respectively after surgery. The difference of Vocal scar formation after surgery between surgical procedures are statistical significance (χ2 = 222.24, P < 0.05). Hoarseness improved after the surgery in 59 cases of Type I , 51 cases of Type II, 43 cases of Type III, 21 cases of Type IV and 17 cases of Type Va. There are statistically significance (χ2 = 89.46, P < 0.05) between different surgical procedures. The parameters of strobe laryngoscope: there are statistical significance on jitter between procedures (F 44.51, P < 0.05), but without difference within Type I and Type II (P > 0.05). This happened in shimmer parameter and the maximum phonation time (MPT) as jitter. There are no statistical significance between Type IV and Type Va on MPT (P > 0.05). Morphological and functional rehabilitation of vocal cord will be affected obviously when the body layer is injured. The depth and range of the CO2 laser microsurgery are the key factors affecting the vocal rehabilitation.
Using Image Modelling to Teach Newton's Laws with the Ollie Trick
ERIC Educational Resources Information Center
Dias, Marco Adriano; Carvalho, Paulo Simeão; Vianna, Deise Miranda
2016-01-01
Image modelling is a video-based teaching tool that is a combination of strobe images and video analysis. This tool can enable a qualitative and a quantitative approach to the teaching of physics, in a much more engaging and appealling way than the traditional expositive practice. In a specific scenario shown in this paper, the Ollie trick, we…
Stroboscopic Vision as a Treatment Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. y.; Kornilova, L. N.; Leigh, R. J.
2006-01-01
Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.
Benchimol, Eric I.; Smeeth, Liam; Guttmann, Astrid; Harron, Katie; Moher, David; Petersen, Irene; Sørensen, Henrik T.; von Elm, Erik; Langan, Sinéad M.
2015-01-01
Routinely collected health data, obtained for administrative and clinical purposes without specific a priori research goals, are increasingly used for research. The rapid evolution and availability of these data have revealed issues not addressed by existing reporting guidelines, such as Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). The REporting of studies Conducted using Observational Routinely collected health Data (RECORD) statement was created to fill these gaps. RECORD was created as an extension to the STROBE statement to address reporting items specific to observational studies using routinely collected health data. RECORD consists of a checklist of 13 items related to the title, abstract, introduction, methods, results, and discussion section of articles, and other information required for inclusion in such research reports. This document contains the checklist and explanatory and elaboration information to enhance the use of the checklist. Examples of good reporting for each RECORD checklist item are also included herein. This document, as well as the accompanying website and message board (http://www.record-statement.org), will enhance the implementation and understanding of RECORD. Through implementation of RECORD, authors, journals editors, and peer reviewers can encourage transparency of research reporting. PMID:26440803
Benchimol, Eric I; Smeeth, Liam; Guttmann, Astrid; Harron, Katie; Moher, David; Petersen, Irene; Sørensen, Henrik T; von Elm, Erik; Langan, Sinéad M
2015-10-01
Routinely collected health data, obtained for administrative and clinical purposes without specific a priori research goals, are increasingly used for research. The rapid evolution and availability of these data have revealed issues not addressed by existing reporting guidelines, such as Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). The REporting of studies Conducted using Observational Routinely collected health Data (RECORD) statement was created to fill these gaps. RECORD was created as an extension to the STROBE statement to address reporting items specific to observational studies using routinely collected health data. RECORD consists of a checklist of 13 items related to the title, abstract, introduction, methods, results, and discussion section of articles, and other information required for inclusion in such research reports. This document contains the checklist and explanatory and elaboration information to enhance the use of the checklist. Examples of good reporting for each RECORD checklist item are also included herein. This document, as well as the accompanying website and message board (http://www.record-statement.org), will enhance the implementation and understanding of RECORD. Through implementation of RECORD, authors, journals editors, and peer reviewers can encourage transparency of research reporting.
Benchimol, Eric I; Smeeth, Liam; Guttmann, Astrid; Harron, Katie; Hemkens, Lars G; Moher, David; Petersen, Irene; Sørensen, Henrik T; von Elm, Erik; Langan, Sinéad M
2016-10-01
Routinely collected health data, obtained for administrative and clinical purposes without specific a priori research goals, are increasingly used for research. The rapid evolution and availability of these data have revealed issues not addressed by existing reporting guidelines, such as Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). The REporting of studies Conducted using Observational Routinely collected health Data (RECORD) statement was created to fill these gaps. RECORD was created as an extension to the STROBE statement to address reporting items specific to observational studies using routinely collected health data. RECORD consists of a checklist of 13 items related to the title, abstract, introduction, methods, results, and discussion section of articles, and other information required for inclusion in such research reports. This document contains the checklist as well as explanatory and elaboration information to enhance the use of the checklist. Examples of good reporting for each RECORD checklist item are also included. This document, as well as the accompanying website and message board (http://www.record-statement.org), will improve the implementation and understanding of RECORD. By implementing RECORD, authors, journals editors, and peer reviewers can enhance transparency of research reporting. Copyright © 2016. Published by Elsevier GmbH.
Meijer, Henny J A; Raghoebar, Gerry M
2012-02-01
The aim of this study was to conduct a review on quality of reporting on descriptive studies in implant dentistry using the STROBE Statement and to analyse possible changes in quality of reporting on descriptive studies in implant dentistry over time. A hand search to select descriptive studies was carried out in seven dental journals, which were thought to have interest in the field of dental implants. Issues of the years 1990, 1995, 2000, 2005 and 2010 were screened. The STROBE Statement with 22 criteria to match was used to determine the quality of an article. Totally 4657 titles and abstracts were screened; 260 of them were found to be reporting on a descriptive study. Percentages of properly addressed items were 46% in 1990, 56% in 1995, 54% in 2000, 59% in 2005 and 70% in 2010. From this review can be concluded that quality of reporting on descriptive studies in implant dentistry is low; there is some improvement from 1990 to 2010, but it does not exceed 70% coverage of the possible to address items. © 2012 John Wiley & Sons A/S.
Array processor architecture connection network
NASA Technical Reports Server (NTRS)
Barnes, George H. (Inventor); Lundstrom, Stephen F. (Inventor); Shafer, Philip E. (Inventor)
1982-01-01
A connection network is disclosed for use between a parallel array of processors and a parallel array of memory modules for establishing non-conflicting data communications paths between requested memory modules and requesting processors. The connection network includes a plurality of switching elements interposed between the processor array and the memory modules array in an Omega networking architecture. Each switching element includes a first and a second processor side port, a first and a second memory module side port, and control logic circuitry for providing data connections between the first and second processor ports and the first and second memory module ports. The control logic circuitry includes strobe logic for examining data arriving at the first and the second processor ports to indicate when the data arriving is requesting data from a requesting processor to a requested memory module. Further, connection circuitry is associated with the strobe logic for examining requesting data arriving at the first and the second processor ports for providing a data connection therefrom to the first and the second memory module ports in response thereto when the data connection so provided does not conflict with a pre-established data connection currently in use.
STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Microseconds to Years
NASA Astrophysics Data System (ADS)
Wilson-Hodge, Colleen A.; Ray, Paul S.; Maccarone, Thomas J.; Chakrabarty, Deepto; Gendreau, Keith C.; Arzoumanian, Zaven; Jenke, Peter; Ballantyne, David; Bozzo, Enrico; Brandt, Soren; Brenneman, Laura; Christophersen, Marc; DeRosa, Alessandra; Feroci, Marco; Goldstein, Adam; Hartmann, Dieter; Hernanz, Margarita; McDonald, Michael; Phlips, Bernard; Remillard, Ronald; Stevens, Abigail; Tomsick, John; Watts, Anna; Wood, Kent S.; Zane, Silvia; STROBE-X Collaboration
2018-01-01
We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with ~20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis. We include updated instrument designs resulting from the GSFC IDL run in November 2017.For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO/Virgo and neutrino events. Extragalactic science, such as constraining bulk metalicity of medium to high redshift clusters and nearby compact groups and unprecedented timing investigations of active galactic nuclei, is also obtained.
STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Microseconds to Years
NASA Astrophysics Data System (ADS)
Wilson-Hodge, Colleen A.; Ray, Paul S.; Gendreau, Keith; Chakrabarty, Deepto; Feroci, Marco; Maccarone, Tom; Arzoumanian, Zaven; Remillard, Ronald A.; Wood, Kent; Griffith, Christopher; STROBE-X Collaboration
2017-01-01
We describe a proposed probe-class mission concept that will provide an unprecedented view of the X-ray sky, performing timing and spectroscopy over a broad band (0.2-30 keV) probing timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises two primary instruments. The soft band (0.2-12 keV) will be covered by an array of lightweight optics (3-m focal length) that concentrate incident photons onto small solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates. This technology, fully developed for NICER, would be scaled up with enhanced optics to take advantage of the longer focal length of STROBE-X. The harder band (2 to at least 30 keV) would be covered by large-area collimated silicon drift detectors,developed for the European LOFT mission concept. Each instrument would provide an order of magnitude improvement in effective area compared with its predecessor (NICER in the soft band and RXTE in the hard band). A sensitive sky monitor would act as a trigger for pointed observations, provide high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with ~20 times the sensitivity of the RXTE ASM, and enable multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis.The broad coverage will enable thermal components, non-thermal components, iron lines, and reflection features to be studied simultaneously from a single platform for the first time in accreting black holes at all scales. The enormous collecting area will enable studies of the dense matter equation of state using both soft thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. Revolutionary science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, would also be obtained.We describe the mission concept and the planned trade studies that will optimize the mission to maximize the science return. This mission is being developed in collaboration with members of the European LOFT team, and a hardware contribution from Europe is expected.
Guitars, Keyboards, Strobes, and Motors -- From Vibrational Motion to Active Research
NASA Astrophysics Data System (ADS)
Tagg, Randall; Carlson, John; Asadi-Zeydabadi, Masoud; Busley, Brad; Law-Balding, Katie; Juengel, Mattea
2013-01-01
Physics First is offered to ninth graders at high schools in Aurora, CO. A unique new asset of this school system is an embedded research lab called the "Innovation Hyperlab." The goal of the lab is to connect secondary school teaching to ongoing university scientific research, supporting the school district's aim to create opportunities to integrate P-20 (preschool to graduate school) learning. This paper is an example of how we create research connections in the context of introductory physics lessons on vibrations and waves. Key to the process is the use of several different types of technical resources, hence the name "hyperlab." Students learn many practical experimental techniques, reinforcing their knowledge of fundamentals and preparing them to work effectively on open-ended research or engineering projects.
Stroke dynamics and frequency of 3 phacoemulsification machines.
Tognetto, Daniele; Cecchini, Paolo; Leon, Pia; Di Nicola, Marta; Ravalico, Giuseppe
2012-02-01
To measure the working frequency and the stroke dynamics of the phaco tip of 3 phacoemulsification machines. University Eye Clinic of Trieste, Italy. Experimental study. A video wet fixture was assembled to measure the working frequency using a micro camera and a micropulsed strobe-light system. A different video wet fixture was created to measure tip displacement as vectorial movement at different phaco powers using a microscopic video apparatus. The working frequency of the Infiniti Ozil machine was 43.0 kHz in longitudinal mode and 31.6 kHz in torsional mode. The frequency of the Whitestar Signature machine was 29.0 kHz in longitudinal mode and 38.0 kHz with the Ellips FX handpiece. The Stellaris machine had a frequency of 28.8 kHz. The longitudinal stroke of the 3 machines at different phaco powers was statistically significantly different. The Stellaris machine had the highest stroke extent (139 μm). The lateral movement of the Infiniti Ozil and Whitestar Signature machines differed significantly. No movement on the y-axis was observed for the Infiniti Ozil machine in torsional mode. The elliptical path of the Ellips FX handpiece had different x and y components at different phaco powers. The 3 phaco machines performed differently in terms of working frequency and stroke dynamics. The knowledge of the peculiar lateral and elliptical path strokes of Infiniti and Whitestar Signature machines may allow the surgeon to fully use these features for lens removal. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
An Experimental Investigation To Determine Interaction Between Rotating Bodies
NASA Technical Reports Server (NTRS)
Grugel, R. N.; Volz, M. P.; Mazuruk, K.
2003-01-01
A brass (copper+zinc) wheel, with a 4-in diameter and 1.4 in thick, was used for this investigation. Ceramic ball bearings were used to safely spin the wheel up to 40,000 rpm. The wheel was also electrically insulated from the rest of the armature. For spinning, an air turbine was used. The rotational velocity was measured by two methods: (1) A simple strobe light and (2) a photodiode that detected laser beam pulses as they passed through a slot in the rotating shaft. The magnetic sensor is based on a giant magnetoresistivity, and consists of a balanced bridge circuitry. The position of the sensor was as close as possible to the rim of the wheel. The linear dimension of the sensor is approximately equal to 8 mm so that the offset from the surface is on the order of 15 percent. We did not use any goniometer system, so the accuracy of the angular position is not high, being estimated within a few degrees, with the main uncertainty being the direction of Earth's magnetic field. We attempted to fit the experimental data with the presented theory by selecting the best value for the electrical conductivity of the wheel. The results of this procedure are displayed, where the black dots represent experimental values. A slight misfit on the right shoulder can be due to slight angular misalignment from a 90 degree position. The obtained value for the resistivity is 43 n(OMEGA)m, which compares well with those listed. We can conclude, based on these measurements, that the proposed theory satisfactorily explains our experiments.
Perry, R.W.; Romine, J.G.; Adams, N.S.; Blake, A.R.; Burau, J.R.; Johnston, S.V.; Liedtke, T.L.
2012-01-01
Anthropogenic alterations to river systems, such as irrigation and hydroelectric development, can negatively affect fish populations by reducing survival when fish are routed through potentially dangerous locations. Non-physical barriers using behavioural stimuli are one means of guiding fish away from such locations without obstructing water flow. In the Sacramento–San Joaquin River Delta, we evaluated a bio-acoustic fish fence (BAFF) composed of strobe lights, sound and a bubble curtain, which was intended to divert juvenile Chinook salmon (Oncorhynchus tshawytscha) away from Georgiana Slough, a low-survival migration route that branches off the Sacramento River. To quantify fish response to the BAFF, we estimated individual entrainment probabilities from two-dimensional movement paths of juvenile salmon implanted with acoustic transmitters. Overall, 7.7% of the fish were entrained into Georgiana Slough when the BAFF was on, and 22.3% were entrained when the BAFF was off, but a number of other factors influenced the performance of the BAFF. The effectiveness of the BAFF declined with increasing river discharge, likely because increased water velocities reduced the ability of fish to avoid being swept across the BAFF into Georgiana Slough. The BAFF reduced entrainment probability by up to 40 percentage points near the critical streakline, which defined the streamwise division of flow vectors entering each channel. However, the effect of the BAFF declined moving in either direction away from the critical streakline. Our study shows how fish behaviour and the environment interacted to influence the performance of a non-physical behavioural barrier in an applied setting.
Emerging optical nanoscopy techniques
Montgomery, Paul C; Leong-Hoi, Audrey
2015-01-01
To face the challenges of modern health care, new imaging techniques with subcellular resolution or detection over wide fields are required. Far field optical nanoscopy presents many new solutions, providing high resolution or detection at high speed. We present a new classification scheme to help appreciate the growing number of optical nanoscopy techniques. We underline an important distinction between superresolution techniques that provide improved resolving power and nanodetection techniques for characterizing unresolved nanostructures. Some of the emerging techniques within these two categories are highlighted with applications in biophysics and medicine. Recent techniques employing wider angle imaging by digital holography and scattering lens microscopy allow superresolution to be achieved for subcellular and even in vivo, imaging without labeling. Nanodetection techniques are divided into four subcategories using contrast, phase, deconvolution, and nanomarkers. Contrast enhancement is illustrated by means of a polarized light-based technique and with strobed phase-contrast microscopy to reveal nanostructures. Very high sensitivity phase measurement using interference microscopy is shown to provide nanometric surface roughness measurement or to reveal internal nanometric structures. Finally, the use of nanomarkers is illustrated with stochastic fluorescence microscopy for mapping intracellular structures. We also present some of the future perspectives of optical nanoscopy. PMID:26491270
Stroboscopic Vision as a Treatment for Retinal Slip Induced Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. J.; Leigh, R. J.; Estrada, A.
2007-01-01
Motion sickness in the general population is a significant problem driven by the increasingly more sophisticated modes of transportation, visual displays, and virtual reality environments. It is important to investigate non-pharmacological alternatives for the prevention of motion sickness for individuals who cannot tolerate the available anti-motion sickness drugs, or who are precluded from medication because of different operational environments. Based on the initial work of Melvill Jones, in which post hoc results indicated that motion sickness symptoms were prevented during visual reversal testing when stroboscopic vision was used to prevent retinal slip, we have evaluated stroboscopic vision as a method of preventing motion sickness in a number of different environments. Specifically, we have undertaken a five part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness while: (1) using visual field reversal, (2) reading while riding in a car (with or without external vision present), (3) making large pitch head movements during parabolic flight, (4) during exposure to rough seas in a small boat, and (5) seated and reading in the cabin area of a UH60 Black Hawk Helicopter during 20 min of provocative flight patterns.
India’s Emerging Security Strategy, Missile Defense, and Arms Control
2004-06-01
and contemplate a security strategy. Starting in July 1998, a series of negotiations between Foreign Minister Jaswant Singh and US envoy Strobe...arms control.46 The Singh -Talbott discussions eventually led to the reaffirmation of civilian command-and-control and a doctrine of “minimum...Council (NSC), including Prime Minister Vajpayee, Minister of Foreign Affairs Singh , and Minister of Defense Fernandes, and appointed a National Security
Extensions of the Ferry shear wave model for active linear and nonlinear microrheology
Mitran, Sorin M.; Forest, M. Gregory; Yao, Lingxing; Lindley, Brandon; Hill, David B.
2009-01-01
The classical oscillatory shear wave model of Ferry et al. [J. Polym. Sci. 2:593-611, (1947)] is extended for active linear and nonlinear microrheology. In the Ferry protocol, oscillation and attenuation lengths of the shear wave measured from strobe photographs determine storage and loss moduli at each frequency of plate oscillation. The microliter volumes typical in biology require modifications of experimental method and theory. Microbead tracking replaces strobe photographs. Reflection from the top boundary yields counterpropagating modes which are modeled here for linear and nonlinear viscoelastic constitutive laws. Furthermore, bulk imposed strain is easily controlled, and we explore the onset of normal stress generation and shear thinning using nonlinear viscoelastic models. For this paper, we present the theory, exact linear and nonlinear solutions where possible, and simulation tools more generally. We then illustrate errors in inverse characterization by application of the Ferry formulas, due to both suppression of wave reflection and nonlinearity, even if there were no experimental error. This shear wave method presents an active and nonlinear analog of the two-point microrheology of Crocker et al. [Phys. Rev. Lett. 85: 888 - 891 (2000)]. Nonlocal (spatially extended) deformations and stresses are propagated through a small volume sample, on wavelengths long relative to bead size. The setup is ideal for exploration of nonlinear threshold behavior. PMID:20011614
Electro-optical imaging systems integration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wight, R.
1987-01-01
Since the advent of high resolution, high data rate electronic sensors for military aircraft, the demands on their counterpart, the image generator hard copy output system, have increased dramatically. This has included support of direct overflight and standoff reconnaissance systems and often has required operation within a military shelter or van. The Tactical Laser Beam Recorder (TLBR) design has met the challenge each time. A third generation (TLBR) was designed and two units delivered to rapidly produce high quality wet process imagery on 5-inch film from a 5-sensor digital image signal input. A modular, in-line wet film processor is includedmore » in the total TLBR (W) system. The system features a rugged optical and transport package that requires virtually no alignment or maintenance. It has a ''Scan FIX'' capability which corrects for scanner fault errors and ''Scan LOC'' system which provides for complete phase synchronism isolation between scanner and digital image data input via strobed, 2-line digital buffers. Electronic gamma adjustment automatically compensates for variable film processing time as the film speed changes to track the sensor. This paper describes the fourth meeting of that challenge, the High Resolution Laser Beam Recorder (HRLBR) for Reconnaissance/Tactical applications.« less
Disruptive Commercial Technologies
2008-06-26
with rotating mirrored “ disco ” balls could be used to blind and confuse Marine forces while masking Red positions. COTS polycarbonate first-responder...specialize in small orders” • Active/passive − Magnesium firebreak − Smoke bombs − 2M candlepower IR illuminators aimed at disco balls − IR strobes...and virtual exercises, we must also equip our irregular OPFOR with the tools they would be likely to acquire and apply against us in creative new ways
Anatomy of an experimental two-link flexible manipulator under end-point control
NASA Technical Reports Server (NTRS)
Oakley, Celia M.; Cannon, Robert H., Jr.
1990-01-01
The design and experimental implementation of an end-point controller for two-link flexible manipulators are presented. The end-point controller is based on linear quadratic Gaussian (LQG) theory and is shown to exhibit significant improvements in trajectory tracking over a conventional controller design. To understand the behavior of the manipulator structure under end-point control, a strobe sequence illustrating the link deflections during a typical slew maneuver is included.
Natural seed fall in white pine (Pinus strobes L.) stands of varying density
Raymond E. Graber
1970-01-01
Seed fall was observed in three stands of mature white pines at stand basal-area densities of 80, 120, and 187 square feet per acre. It was found that the intermediate-density stand produced nearly 50 percent more seed than the stands of other densities. During a good seed year this stand produced 59 pounds of dry sound seed per acre. Most of the seeds were dispersed...
Large Structure in the Far Wakes of Two-Dimensional Bluff Bodies,
1984-01-01
triggered along with a strobe flash to record the streakline pattern on film . The electronic synchronizing controller for the smoke-wire operation was built...Super 35 mm camera with motor drive was used, along with a General Radio Model 1540 Stroboscope. We had the best success with Kodak Tri-x film pushed one...location being considered, its entire history is contained in the streakline pattern, and may confuse the intepretation . The conclusion from this
Psychosocial correlates of depression following spinal injury: A systematic review
Kraft, Rebekah
2015-01-01
Objectives Spinal cord injury (SCI) studies have identified a range of psychosocial risk and protective factors for depression post-injury. This study presents the first systematic and quantitative review of this body of research. Methods Twenty-four studies (N = 3172 participants) were identified through electronic database searches. Studies were evaluated according to recommended guidelines on Strengthening the Reporting of Observational Studies in Epidemiology (STROBE). The significance and magnitude of the relationships between standardised measures of depression and psychosocial outcome were examined using Pearson's effect size r, 95% confidence intervals and fail-safe Ns. Effect sizes were categorised according to the ICF psychosocial domains. Results STROBE ratings indicated discrepancies in procedural detail and statistical analyses. Individual personal variables including affective feelings, and thoughts and beliefs specific to SCI demonstrated the strongest relationship with depression self-ratings. Life satisfaction, disability acceptance, environmental supports and community participation had a medium to strong association, helping to reduce vulnerability to depression. Longitudinal studies revealed that symptoms of depression continued to impact on psychosocial outcome up to 10 years post-injury, although this was based on limited data. Conclusions Assessment of psychosocial factors in the acute stages of SCI rehabilitation can inform evidence-based interventions to treat and manage depressive symptomatology in the short to longer-term. Future studies would benefit from adopting a unified approach to the measurement of depression post-SCI to help inform targeted treatment. PMID:25691222
NASA Astrophysics Data System (ADS)
Han, Bing; Liu, Liu; Ni, Xiao-Wu
2017-08-01
In order to understand the interaction dynamics of a pair of laser-induced bubbles, a double-exposure strobe photography experimental setup is build up to study the temporal evolution of the bubble pairs and to measure the transient bubble-interface moving speed. The interaction mechanisms of the bubble pairs are discussed together with the numerical results obtained through OpenFOAM. It is shown that the direction and the velocity of the jetting could be controlled by the relative size and the relative initiation distance of the bubble pair, when the bubbles are generated at the same time, i.e., in-phase. The liquid jet is considered to be a penetrating jet. The jet is originated from the smaller bubble and clearly protruding outside of the bigger bubble. The parameter space of the relative size and the initiation distance of the bubble pair allowing the formation of the penetrating jet are very narrow. It is concluded that the liquid jet induced by the bubble interactions resulted from the collapse and the rebound of the smaller bubble nearby the bigger bubble. This is defined as the "catapult effect." Such a directional liquid transportation is a promising tool as a micro-injector or a micro-pump. The investigation results could be also supplementary to the understandings of the bubble dynamics.
Cavitation phenomena in mechanical heart valves: studied by using a physical impinging rod system.
Lo, Chi-Wen; Chen, Sheng-Fu; Li, Chi-Pei; Lu, Po-Chien
2010-10-01
When studying mechanical heart valve cavitation, a physical model allows direct flow field and pressure measurements that are difficult to perform with actual valves, as well as separate testing of water hammer and squeeze flow effects. Movable rods of 5 and 10 mm diameter impinged same-sized stationary rods to simulate squeeze flow. A 24 mm piston within a tube simulated water hammer. Adding a 5 mm stationary rod within the tube generated both effects simultaneously. Charged-coupled device (CCD) laser displacement sensors, strobe lighting technique, laser Doppler velocimetry (LDV), particle image velocimetry (PIV) and high fidelity piezoelectric pressure transducers measured impact velocities, cavitation images, squeeze flow velocities, vortices, and pressure changes at impact, respectively. The movable rods created cavitation at critical impact velocities of 1.6 and 1.2 m/s; squeeze flow velocities were 2.8 and 4.64 m/s. The isolated water hammer created cavitation at 1.3 m/s piston speed. The combined piston and stationary rod created cavitation at an impact speed of 0.9 m/s and squeeze flow of 3.2 m/s. These results show squeeze flow alone caused cavitation, notably at lower impact velocity as contact area increased. Water hammer alone also caused cavitation with faster displacement. Both effects together were additive. The pressure change at the vortex center was only 150 mmHg, which cannot generate the magnitude of pressure drop required for cavitation bubble formation. Cavitation occurred at 3-5 m/s squeeze flow, significantly different from the 14 m/s derived by Bernoulli's equation; the temporal acceleration of unsteady flow requires further study.
Place preference and vocal learning rely on distinct reinforcers in songbirds.
Murdoch, Don; Chen, Ruidong; Goldberg, Jesse H
2018-04-30
In reinforcement learning (RL) agents are typically tasked with maximizing a single objective function such as reward. But it remains poorly understood how agents might pursue distinct objectives at once. In machines, multiobjective RL can be achieved by dividing a single agent into multiple sub-agents, each of which is shaped by agent-specific reinforcement, but it remains unknown if animals adopt this strategy. Here we use songbirds to test if navigation and singing, two behaviors with distinct objectives, can be differentially reinforced. We demonstrate that strobe flashes aversively condition place preference but not song syllables. Brief noise bursts aversively condition song syllables but positively reinforce place preference. Thus distinct behavior-generating systems, or agencies, within a single animal can be shaped by correspondingly distinct reinforcement signals. Our findings suggest that spatially segregated vocal circuits can solve a credit assignment problem associated with multiobjective learning.
Design Notebook for Naval Air Defense Simulation (NADS). Revision.
1986-10-09
OK 304 On Cap 105 Self Assign NoGo *305 TDS Down 106 On Self Control 306 Controller Status Change 107 Red Fighter 307 Reject Control 108 Intercept...range for RED aircraft INTEGER*2 COMTDS, I message delay time between TDS F-19 units COMVCE, I message delay if either unit is F-19 * non- TDS TWAITC...reschedule A/C launch LOGICAL*I NUCREL, I nuclear weapons release for force AUTOESM, I ESM bearing ( jamming strobes) automatically updated in TDS
Stroboscopic Goggles for Reduction of Motion Sickness
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Somers, Jeffrey T.
2005-01-01
A device built around a pair of electronic shutters has been demonstrated to be effective as a prototype of stroboscopic goggles or eyeglasses for preventing or reducing motion sickness. The momentary opening of the shutters helps to suppress a phenomenon that is known in the art as retinal slip and is described more fully below. While a number of different environmental factors can induce motion sickness, a common factor associated with every known motion environment is sensory confusion or sensory mismatch. Motion sickness is a product of misinformation arriving at a central point in the nervous system from the senses from which one determines one s spatial orientation. When information from the eyes, ears, joints, and pressure receptors are all in agreement as to one s orientation, there is no motion sickness. When one or more sensory input(s) to the brain is not expected, or conflicts with what is anticipated, the end product is motion sickness. Normally, an observer s eye moves, compensating for the anticipated effect of motion, in such a manner that the image of an object moving relatively to an observer is held stationary on the retina. In almost every known environment that induces motion sickness, a change in the gain (in the signal-processing sense of gain ) of the vestibular system causes the motion of the eye to fail to hold images stationary on the retina, and the resulting motion of the images is termed retinal slip. The present concept of stroboscopic goggles or eyeglasses (see figure) is based on the proposition that prevention of retinal slip, and hence, the prevention of sensory mismatch, can be expected to reduce the tendency toward motion sickness. A device according to this concept helps to prevent retinal slip by providing snapshots of the visual environment through electronic shutters that are brief enough that each snapshot freezes the image on each retina. The exposure time for each snapshot is less than 5 ms. In the event that a higher rate of strobing is necessary for adequate viewing of the changing scene during rapid head movements, the rate of strobing (but not the exposure time) can be controlled in response to the readings of rate-of-rotation sensors attached to the device.
Li, Ying; Li, Xiao-Hui; Huang, Xin; Yin, Lu; Guo, Cheng-Xian; Liu, Chang; He, Yong-Mei; Liu, Xing; Yuan, Hong
2017-11-01
Traditional Chinese Medicine Constitution (TCMC) theory states that individuals with a biased TCMC are more likely to suffer from specific diseases. However, little is known regarding the influence of TCMC on susceptibility to hypertension. The aim of this study is to examine the possible relationship between TCMC and hypertension. Retrospective evaluation and observation were performed using the STROBE guidelines checklist. A large community-based cross-sectional study was conducted between 2009 and 2013 in Changsha, China. TCMC was assessed using a questionnaire that included 68 items. TCMC distributions and the associations of different TCMCs with hypertension risk were analyzed. In total, 144,439 subjects underwent evaluations of TCMC and blood pressure (BP). There were significant differences in the hypertension prevalence among the various TCMC groups (P < .01). An adjusted logistic regression model indicated that those with phlegm wetness, yin deficiency, blood stasis, or qi deficiency were more likely to have hypertension. Analysis of the clinical characteristics related to TCMC indicated that different TCMCs corresponded to different hypertension classifications using Western medicine criteria; for example, phlegm wetness with hypertension was similar to obesity-related hypertension. Our results suggest that phlegm wetness, yin deficiency, blood stasis, and qi deficiency have different effects on the prevalence of hypertension. More attention should be paid to TCMCs associated with susceptibility to hypertension, and corresponding preventive and therapeutic treatments should be developed according to different TCMCs.
Stroboscopic Training Enhances Anticipatory Timing.
Smith, Trevor Q; Mitroff, Stephen R
The dynamic aspects of sports often place heavy demands on visual processing. As such, an important goal for sports training should be to enhance visual abilities. Recent research has suggested that training in a stroboscopic environment, where visual experiences alternate between visible and obscured, may provide a means of improving attentional and visual abilities. The current study explored whether stroboscopic training could impact anticipatory timing - the ability to predict where a moving stimulus will be at a specific point in time. Anticipatory timing is a critical skill for both sports and non-sports activities, and thus finding training improvements could have broad impacts. Participants completed a pre-training assessment that used a Bassin Anticipation Timer to measure their abilities to accurately predict the timing of a moving visual stimulus. Immediately after this initial assessment, the participants completed training trials, but in one of two conditions. Those in the Control condition proceeded as before with no change. Those in the Strobe condition completed the training trials while wearing specialized eyewear that had lenses that alternated between transparent and opaque (rate of 100ms visible to 150ms opaque). Post-training assessments were administered immediately after training, 10-minutes after training, and 10-days after training. Compared to the Control group, the Strobe group was significantly more accurate immediately after training, was more likely to respond early than to respond late immediately after training and 10 minutes later, and was more consistent in their timing estimates immediately after training and 10 minutes later.
Real-time Awake Animal Motion Tracking System for SPECT Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goddard Jr, James Samuel; Baba, Justin S; Lee, Seung Joon
Enhancements have been made in the development of a real-time optical pose measurement and tracking system that provides 3D position and orientation data for a single photon emission computed tomography (SPECT) imaging system for awake, unanesthetized, unrestrained small animals. Three optical cameras with infrared (IR) illumination view the head movements of an animal enclosed in a transparent burrow. Markers placed on the head provide landmark points for image segmentation. Strobed IR LED s are synchronized to the cameras and illuminate the markers to prevent motion blur for each set of images. The system using the three cameras automatically segments themore » markers, detects missing data, rejects false reflections, performs trinocular marker correspondence, and calculates the 3D pose of the animal s head. Improvements have been made in methods for segmentation, tracking, and 3D calculation to give higher speed and more accurate measurements during a scan. The optical hardware has been installed within a Siemens MicroCAT II small animal scanner at Johns Hopkins without requiring functional changes to the scanner operation. The system has undergone testing using both phantoms and live mice and has been characterized in terms of speed, accuracy, robustness, and reliability. Experimental data showing these motion tracking results are given.« less
1987-01-01
prepoftderantly negative policyr will ... retard the decision" in war.3 This observation also fits my detloltioft. i 2Carl von Clausewitz, On Wa trans ...var. but also the enemy’s xi to fight. In the United States. strategic bombing proponents 1Carl von Clausewitz, OnIWa trans . and ed. Michael Hovard and...Khruahchev. Khrushchov Rembers trans . and ed. Strobe Talbott (Boston: Little, Brown. and Company, 1970), pp. 367-372. 36 Ma•elkov. LAvrentil BriA, Lad
Spread spectrum phase modulation for coherent X-ray diffraction imaging.
Zhang, Xuesong; Jiang, Jing; Xiangli, Bin; Arce, Gonzalo R
2015-09-21
High dynamic range, phase ambiguity and radiation limited resolution are three challenging issues in coherent X-ray diffraction imaging (CXDI), which limit the achievable imaging resolution. This paper proposes a spread spectrum phase modulation (SSPM) method to address the aforementioned problems in a single strobe. The requirements on phase modulator parameters are presented, and a practical implementation of SSPM is discussed via ray optics analysis. Numerical experiments demonstrate the performance of SSPM under the constraint of available X-ray optics fabrication accuracy, showing its potential to real CXDI applications.
Suppression of vortex-induced vibrations in a flexible cylinder with elastic splitter plates
NASA Astrophysics Data System (ADS)
Huera-Huarte, Francisco
2013-11-01
Suppression of vortex-induced vibrations (VIV) is a topic that has received a lot of attention due to its practical implications in engineering design. Experiments have been conducted in a recirculating free surface water channel, with a working section of dimensions 1 × 1.1 × 2.5 m. A cylinder model made of a spring and a plastic cover was used for the experiments. It was placed horizontally and fully submerged in the water channel's free stream, hanging from two submersible load cells arranged to measure the total drag force on the cylinder. The model had several white points painted on its surface, so its VIV motion was obtained by imaging it with two cameras synchronised with a strobe light. Image processing allowed to obtain the displacements along the length of the cylinder with sub-pixel accuracy. Digital Particle Image Velocimetry (DPIV) was also used to quantify the wake downstream the cylinder. A full set of experiments was made for reference purposes with a plain cylinder without suppressors, and for the same conditions, several passive suppression devices such as elastic splitter plates of different sizes and shapes, were installed on the cylinder. Passive VIV suppression with drag reduction was achieved with some of the configurations tested. Funding provided by the Spanish Ministry of Science through grant DPI2012-37904 is acknowledged.
Branjerdporn, Grace; Meredith, Pamela; Strong, Jenny; Garcia, Jenniffer
2017-03-01
Objectives Infant developmental outcomes may be influenced by a range of prenatal maternal characteristics. While there is some evidence to suggest that maternal-foetal attachment may be associated with infant developmental outcomes, there is a need to systematically review this evidence to guide future research and clinical practice. Methods Five electronic databases were systematically scanned. Key journals and reference lists were hand-searched. Papers were included if: (1) pregnant women were assessed for maternal-foetal attachment; (2) the infants were later assessed, under 2 years old, for any developmental outcome (e.g., social-emotional, cognition, motor, language, adaptive behaviour); and (3) they were published in English. Two independent reviewers used the STROBE checklist to appraise the quality of each paper. Results Of the 968 papers identified, eight were included in the review, and four of these were of low quality (<60 %) based on the STROBE. The developmental domains that were examined included: infant temperament (n = 5), adaptive behaviour (e.g., colic, sleep) (n = 2), and milestone attainment (n = 1). There is some evidence to suggest that lower maternal-foetal attachment is related to suboptimal developmental outcomes. However, these results should be interpreted with caution due to the limited and low quality studies available. Conclusions Although maternal-foetal attachment may be associated with infant developmental outcomes, future research is required which: (1) considers a range of developmental outcomes, (2) has increased scientific rigour, (3) assesses mother-infant dyads at different prenatal and postnatal time points, and (4) examines different target populations.
Photopsias: A Key to Diagnosis.
Brown, Gary C; Brown, Melissa M; Fischer, David H
2015-10-01
To assess the character and cause of photopsias in vitreoretinal patients. Cross-sectional study. A total of 169 consecutive patients (217 eyes) with vitreoretinal disease presenting with a history of photopsias. A total of 217 eyes with photopsias in 169 patients were evaluated. Photopsia assessment included (1) laterality (unilateral, bilateral but not simultaneous, bilateral, and simultaneous); (2) morphology (flash, zig-zag, strobe, scintillating scotoma, twinkling, other); (3) color (white, silver, yellow, combination, other); (4) location (temporal, central, other); (5) duration (quick, prolonged, constant, other); (6) frequency; (7) diurnal appearance (day, night, both); (8) stimuli (turning head or eyes, hypoglycemia, hyperglycemia, other); and (9) associated systemic or ocular signs and symptoms (headache, numbness, weakness, vertigo, syncope, diplopia, hypotension, floaters, other). Clinical photopsia features correlated with the causes of photopsias. Thirty-two photopsia causes were identified. The top 16 included posterior vitreous detachment (PVD) in 39.7% of eyes; retinal tear in 8.9% of eyes; neovascular age-related macular degeneration (AMD) in 7.9% of eyes; rhegmatogenous retinal detachment (RRD) in 7.5% of eyes; classic and ophthalmic migraine in 6.5% of eyes; hypoglycemia in 2.8% of eyes; vertebrobasilar insufficiency in 2.8% of eyes; non-AMD choroidal neovascularization in 2.3% of eyes; retinitis pigmentosa in 1.9% of eyes; severe cough in 1.9% of eyes; central serous chorioretinopathy in 1.4% of eyes; intraocular lens reflections in 0.9% of eyes; blue field entoptic phenomenon in 0.9% of eyes; Charles Bonnet syndrome in 0.9% of eyes; digitalis in 0.9% of eyes; and metastatic adenocarcinoma to the brain in 0.9% of eyes. The photopsias associated with PVD are typically quick (96%), with lightning/flash morphology (96%), white (87%), temporally located (86%), associated with new-onset floaters (85%), preferentially seen in dark (90%) rather than lighted environments (29%), and often initiated by head/eye movements (60%). Retinal detachment had a similar profile, but with more nontemporal photopsias (40%) (P = 0.01). The photopsias from neovascular AMD are more centrally located (83%), quick and repetitive (79%), seen in light (73%) and dark (63%) environments, have no inciting stimuli (84%), and are more likely to be nonwhite (40%). A pointed history for photopsias can reveal a cause that may not initially seem apparent. Thus, the history can play a key role in management decisions. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Yoon, Uzung; Knobloch, Karsten
2012-04-11
The preliminary results of a study are usually presented as an abstract in conference meetings. The reporting quality of those abstracts and the relationship between their study designs and full paper publication rate is unknown. We hypothesized that randomized controlled trials are more likely to be published as full papers than observational studies. 154 oral abstracts presented at the World Congress of Sports Injury Prevention 2005 Oslo and the corresponding full paper publication were identified and analysed. The main outcome measures were frequency of publication, time to publication, impact factor, CONSORT (for Consolidated Standards of Reporting Trials) score, STROBE (for Strengthening the Reporting of Observational Studies in Epidemiology) score, and minor and major inconsistencies between the abstract and the full paper publication. Overall, 76 of the 154 (49%) presented abstracts were published as full papers in a peer-reviewed journal with an impact factor of 1.946 ± 0.812. No significant difference existed between the impact factor for randomized controlled trials (2.122 ± 1.015) and observational studies (1.913 ± 0.765, p = 0.469). The full papers for the randomized controlled trials were published after an average (SD) of 17 months (± 13 months); for observational studies, the average (SD) was 12 months (± 14 months) (p = 0.323). A trend was observed in this study that a higher percentage of randomized controlled trial abstracts were published as full papers (71% vs. 47%, p = 0.078) than observational trials. The reporting quality of abstracts, published as full papers, significantly increased compared to conference abstracts both in randomized control studies ( 5.7 ± 0.7 to 7.2 ± 1.3; p = 0.018, CI -2.7 to -0.32) and in observational studies (STROBE: 8.2 ± 1.3 to 8.6 ± 1.4; p = 0.007, CI -0.63 to -0.10). All of the published abstracts had at least one minor inconsistency (title, authors, research center, outcome presentation, conclusion), while 65% had at least major inconsistencies (study objective, hypothesis, study design, primary outcome measures, sample size, statistical analysis, results, SD/CI). Comparing the results of conference and full paper; results changed in 90% vs. 68% (randomized, controlled studies versus observational studies); data were added (full paper reported more result data) in 60% vs. 30%, and deleted (full paper reported fewer result data) in 40% vs. 30%. No significant differences with respect to type of study (randomized controlled versus observational), impact factor, and time to publication existed for the likelihood that a World Congress of Sports Injury conference abstract could be published as a full paper.
Wilkins, Luke; Gray, Rob
2015-08-01
It has been shown recently that stroboscopic visual training can improve visual-perceptual abilities, such as central field motion sensitivity and anticipatory timing. Such training should also improve a sports skill that relies on these perceptual abilities, namely ball catching. Thirty athletes (12 women, 18 men; M age=22.5 yr., SD=4.7) were assigned to one of two types of stroboscopic training groups: a variable strobe rate (VSR) group for which the off-time of the glasses was systematically increased (as in previous research) and a constant strobe rate group (CSR) for which the glasses were always set at the shortest off-time. Training involved simple, tennis ball-catching drills (9×20 min.) occurring over a 6-wk. In pre- and post-training, the participants completed a one-handed ball-catching task and the Useful Field of View (UFOV) and the Motion in Depth Sensitivity (MIDS) tests. Since the CSR condition used in the present study has been shown to have no effect on catching performance, it was predicted that the VSR group would show significantly greater improvement pre-post-training. There were no significant differences between the CSR and VSR on any of the tests. However, changes in catching performance (total balls caught) pre-post-training were significantly correlated with changes in scores for the UFOV single-task and MIDS tests. That is, regardless of group, participants whose perceptual-cognitive performance improved in the post-test were significantly more likely to improve their catching performance. This suggests that the perceptual changes observed in previous stroboscopic training studies may be linked to changes in sports skill performance.
de Mendonça Cardoso, Marcio; Gepp, Ricardo; Correa, José Fernando Guedes
2016-09-01
The phrenic nerve can be transferred to the musculocutaneous nerve in patients with traumatic brachial plexus palsy in order to recover biceps strength, but the results are controversial. There is also a concern about pulmonary function after phrenic nerve transection. In this paper, we performed a qualitative systematic review, evaluating outcomes after this procedure. A systematic review of published studies was undertaken in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement. Data were extracted from the selected papers and related to: publication, study design, outcome (biceps strength in accordance with BMRC and pulmonary function) and population. Study quality was assessed using the "strengthening the reporting of observational studies in epidemiology" (STROBE) standard or the CONSORT checklist, depending on the study design. Seven studies were selected for this systematic review after applying inclusion and exclusion criteria. One hundred twenty-four patients completed follow-up, and most of them were graded M3 or M4 (70.1 %) for biceps strength at the final evaluation. Pulmonary function was analyzed in five studies. It was not possible to perform a statistical comparison between studies because the authors used different parameters for evaluation. Most of the patients exhibited a decrease in pulmonary function tests immediately after surgery, with recovery in the following months. Study quality was determined using STROBE in six articles, and the global score varied from 8 to 21. Phrenic nerve transfer to the musculocutaneous nerve can recover biceps strength ≥M3 (BMRC) in most patients with traumatic brachial plexus injury. Early postoperative findings revealed that the development of pulmonary symptoms is rare, but it cannot be concluded that the procedure is safe because there is no study evaluating pulmonary function in old age.
Mabikwa, Onkabetse V; Greenwood, Darren C; Baxter, Paul D; Fleming, Sarah J
2017-03-14
One aspect to consider when reporting results of observational studies in epidemiology is how quantitative risk factors are analysed. The STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines recommend that researchers describe how they handle quantitative variables when analysing data. For categorised quantitative variables, the authors are required to provide reasons and justifications informing their practice. We investigated and assessed the practices and reporting of categorised quantitative variables in epidemiology. The assessment was based on five medical journals that publish epidemiological research. Observational studies published between April and June 2015 and investigating the relationships between quantitative exposures (or risk factors) and the outcomes were considered for assessment. A standard form was used to collect the data, and the reporting patterns amongst eligible studies were quantified and described. Out of 61 articles assessed for eligibility, 23 observational studies were included in the assessment. Categorisation of quantitative exposures occurred in 61% of these studies and reasons informing the practice were rarely provided. Only one article explained the choice of categorisation in the analysis. Transformation of quantitative exposures into four or five groups was common and dominant amongst studies using equally spaced categories. Dichotomisation was not popular; the practice featured in one article. Overall, the majority (86%) of the studies preferred ordered or arbitrary group categories. Other criterions used to decide categorical boundaries were based on established guidelines such as consensus statements and WHO standards. Categorisation of continuous variables remains a dominant practice in epidemiological studies. The reasons informing the practice of categorisation within published work are limited and remain unknown in most articles. The existing STROBE guidelines could provide stronger recommendations on reporting quantitative risk factors in epidemiology.
Methodological issues in oral health research: intervention studies.
O'Mullane, Denis; James, Patrice; Whelton, Helen; Parnell, Carmel
2012-02-01
To provide a broad overview of methodological issues in the design and evaluation of intervention studies in dental public health, with particular emphasis on explanatory trials, pragmatic trials and complex interventions. We present a narrative summary of selected publications from the literature outlining both historical and recent challenges in the design and evaluation of intervention studies and describe some recent tools that may help researchers to address these challenges. It is now recognised that few intervention studies in dental public health are purely explanatory or pragmatic. We describe the PRECIS tool which can be used by trialists to assess and display the position of their trial on a continuum between the extremes of explanatory and pragmatic trials. The tool aims to help trialists make design decisions that are in line with their stated aims. The increasingly complex nature of dental public health interventions presents particular design and evaluation challenges. The revised Medical Research Council (MRC) guidance for the development and evaluation of complex interventions which emphasises the importance of planning and process evaluation is a welcome development. We briefly describe the MRC guidance and outline some examples of complex interventions in the field of oral health. The role of observational studies in monitoring public health interventions when the conduct of RCTs is not appropriate or feasible is acknowledged. We describe the STROBE statement and outline the implications of the STROBE guidelines for dental public health. The methodological challenges in the design, conduct and reporting of intervention studies in oral health are considerable. The need to provide reliable evidence to support innovative new strategies in oral health policy is a major impetus in these fields. No doubt the 'Methodological Issues in Oral Health Research' group will have further opportunities to highlight this work. © 2012 John Wiley & Sons A/S.
Characterization of multiport solid state imagers at megahertz data rates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yates, G.J.; Pena, C.R.; Turko, B.T.
1994-08-01
Test results obtained from two recently developed multiport Charge-Coupled Devices (CCDs) operated at pixel rates in the 10-to-100 MHz range will be presented . The CCDs were evaluated in Los Alamos National Laboratory`s High Speed Solid State Imager Test Station (HSTS) which features PC-based programmable clock waveform generation (Tektronix DAS 9200) and synchronously clocked Digital Sampling Oscilloscopes (DSOs) (LeCroy 9424/9314 series) for CCD pixel data acquisition, analysis and storage. The HSTS also provided special designed optical pinhole array test patterns in the 5-to-50 micron diameter range for use with Xenon Strobe and pulsed laser light sources to simultaneously provide multiplemore » single-pixel illumination patterns to study CCD point-spread-function (PSF) and pixel smear characteristics. The two CCDs tested, EEV model CCD-13 and EG&G Reticon model HSO512J, are both 512 {times} 512 pixel arrays with eight (8) and sixteen (16) video output ports respectively. Both devices are generically Frame Transfer CCDs (FT CCDs) designed for parallel bi-directional vertical readout to augment their multiport design for increased pixel rates over common single port serial readout architecture. Although both CCDs were tested similarly, differences in their designs precluded normalization or any direct comparisons of test results. Rate dependent parameters investigated include S/N, PSF, and MTF. The performance observed for the two imagers at various pixel rates from selected typical output ports is discussed.« less
O'Reilly, Martin; Caulfield, Brian; Ward, Tomas; Johnston, William; Doherty, Cailbhe
2018-05-01
Analysis of lower limb exercises is traditionally completed with four distinct methods: (1) 3D motion capture; (2) depth-camera-based systems; (3) visual analysis from a qualified exercise professional; and (4) self-assessment. Each method is associated with a number of limitations. The aim of this systematic review is to synthesise and evaluate studies which have investigated the capacity for inertial measurement unit (IMU) technologies to assess movement quality in lower limb exercises. A systematic review of studies identified through the databases of PubMed, ScienceDirect and Scopus was conducted. Articles written in English and published in the last 10 years which investigated an IMU system for the analysis of repetition-based targeted lower limb exercises were included. The quality of included studies was measured using an adapted version of the STROBE assessment criteria for cross-sectional studies. The studies were categorised into three groupings: exercise detection, movement classification or measurement validation. Each study was then qualitatively summarised. From the 2452 articles that were identified with the search strategies, 47 papers are included in this review. Twenty-six of the 47 included studies were deemed as being of high quality. Wearable inertial sensor systems for analysing lower limb exercises is a rapidly growing field of research. Research over the past 10 years has predominantly focused on validating measurements that the systems produce and classifying users' exercise quality. There have been very few user evaluation studies and no clinical trials in this field to date.
The potential impact of multidimesional geriatric assessment in the social security system.
Corbi, Graziamaria; Ambrosino, Immacolata; Massari, Marco; De Lucia, Onofrio; Simplicio, Sirio; Dragone, Michele; Paolisso, Giuseppe; Piccioni, Massimo; Ferrara, Nicola; Campobasso, Carlo Pietro
2018-01-12
To evaluate the efficacy of multidimensional geriatric assessment (MGA/CGA) in patients over 65 years old in predicting the release of the accompaniment allowance (AA) indemnity by a Local Medico-Legal Committee (MLC-NHS) and by the National Institute of Social Security Committee (MLC-INPS). In a longitudinal observational study, 200 Italian elder citizens requesting AA were first evaluated by MLC-NHS and later by MLC-INPS. Only MLC-INPS performed a MGA/CGA (including SPMSQ, Barthel Index, GDS-SF, and CIRS). This report was written according to the STROBE guidelines. The data analysis was performed on January 2016. The evaluation by the MLC-NHS and by the MLC-INPS was in agreement in 66% of cases. In the 28%, the AA benefit was recognized by the MLC-NHS, but not by the MLC-INPS. By the multivariate analysis, the best predictors of the AA release, by the MLC-NHS, were represented by gender and the Barthel Index score. The presence of carcinoma, the Barthel Index score, and the SPMQ score were the best predictors for the AA release by MLC-INPS. MGA/CGA could be useful in saving financial resources reducing the risk of incorrect indemnity release. It can improve the accuracy of the impairment assessment in social security system.
The Effect of Periodontitis on Expression of Interleukin-21: A Systematic Review
Mootha, Archana; Malaiappan, Sankari; Jayakumar, N. D.; Varghese, Sheeja S.; Toby Thomas, Julie
2016-01-01
Purpose. Inflammation and tissue breakdown are led by an array of inflammatory destructive mediators associated with initiation and progression of inflammatory diseases like periodontitis. Current evidence shows that these inflammatory mediators have a definitive role in the pathogenesis of various systemic diseases with an inflammatory component. Interleukin-21 (IL-21) has been associated with systemic diseases like rheumatoid arthritis and Crohn's disease that follow a chronic inflammatory cascade. Similarly recent studies have associated Interleukin-21 levels with periodontitis. This systematic review was aimed to assess the levels of IL-21 in subjects with periodontitis. Methods. A complete literature search was done in PubMed, Medline, Science Direct, and Cochrane databases and Google Scholar based on the inclusion/exclusion criteria. Six relevant articles were procured. Full text was read individually by two reviewers and data extraction was done based on STROBE statement. Results. After data extraction five observational and one interventional study were obtained. All the studies showed an increased expression of IL-21 in periodontitis and the interventional study showed reduction in IL-21 levels after nonsurgical periodontal therapy (NSP). Conclusion. Interleukin-21 levels are higher in periodontitis than controls. With this limited evidence further longitudinal studies are required to consider this as a definitive inflammatory marker. PMID:26998377
Final Technical Report: Development of Post-Installation Monitoring Capabilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polagye, Brian
2014-03-31
The development of approaches to harness marine and hydrokinetic energy at large-scale is predicated on the compatibility of these generation technologies with the marine environment. At present, aspects of this compatibility are uncertain. Demonstration projects provide an opportunity to address these uncertainties in a way that moves the entire industry forward. However, the monitoring capabilities to realize these advances are often under-developed in comparison to the marine and hydrokinetic energy technologies being studied. Public Utility District No. 1 of Snohomish County has proposed to deploy two 6-meter diameter tidal turbines manufactured by OpenHydro in northern Admiralty Inlet, Puget Sound, Washington.more » The goal of this deployment is to provide information about the environmental, technical, and economic performance of such turbines that can advance the development of larger-scale tidal energy projects, both in the United States and internationally. The objective of this particular project was to develop environmental monitoring plans in collaboration with resource agencies, while simultaneously advancing the capabilities of monitoring technologies to the point that they could be realistically implemented as part of these plans. In this, the District was joined by researchers at the Northwest National Marine Renewable Energy Center at the University of Washington, Sea Mammal Research Unit, LLC, H.T. Harvey & Associates, and Pacific Northwest National Laboratory. Over a two year period, the project team successfully developed four environmental monitoring and mitigation plans that were adopted as a condition of the operating license for the demonstration project that issued by the Federal Energy Regulatory Commission in March 2014. These plans address nearturbine interactions with marine animals, the sound produced by the turbines, marine mammal behavioral changes associated with the turbines, and changes to benthic habitat associated with colonization of the subsea base support structure. In support of these plans, the project team developed and field tested a strobe-illuminated stereooptical camera system suitable for studying near-turbine interactions with marine animals. The camera system underwent short-term field testing at the proposed turbine deployment site and a multi-month endurance test in shallower water to evaluate the effectiveness of biofouling mitigation measures for the optical ports on camera and strobe pressure housings. These tests demonstrated that the camera system is likely to meet the objectives of the near-turbine monitoring plan and operate, without maintenance, for periods of at least three months. The project team also advanced monitoring capabilities related to passive acoustic monitoring of marine mammals and monitoring of tidal currents. These capabilities will be integrated in a recoverable monitoring package that has a single interface point with the OpenHydro turbines, connects to shore power and data via a wet-mate connector, and can be recovered to the surface for maintenance and reconfiguration independent of the turbine. A logical next step would be to integrate these instruments within the package, such that one instrument can trigger the operation of another.« less
NASA Technical Reports Server (NTRS)
Thiessen, D. B.; Young, J. E.; Marr-Lyon, M. J.; Richardson, S. L.; Breckon, C. D.; Douthit, S. G.; Jian, P. S.; Torruellas, W. E.; Marston, P. L.
1999-01-01
Several groups of researchers have demonstrated that high frequency sound in water may be used to cause the regular repeated compression and luminescence of a small bubble of gas in a flask. The phenomenon is known as single bubble sonoluminescence (SBSL). It is potentially important because light emitted by the bubble appears to be associated with a significant concentration of energy within the volume of the bubble. Unfortunately, the detailed physical mechanisms causing the radiation of light by oscillating bubbles are poorly understood and there is some evidence that carrying out experiments in a weightless environment may provide helpful clues. In addition, the radiation pressure of laser beams on the bubble may provide a way of simulating weightless experiments in the laboratory. The standard model of SBSL attributes the light emission to heating within the bubble by a spherically imploding shock wave to achieve temperatures of 50,000 K or greater. In an alternative model, the emission is attributed to the impact of a jet of water which is required to span the bubble and the formation of the jet is linked to the buoyancy of the bubble. The coupling between buoyancy and jet formation is a consequence of the displacement of the bubble from a velocity node (pressure antinode) of the standing acoustic wave that drives the radial bubble oscillations. One objective of this grant is to understand SBSL emission in reduced buoyancy on KC-135 parabolic flights. To optimize the design of those experiments and for other reasons which will help resolve the role of buoyancy, laboratory experiments are planned in simulated low gravity in which the radiation pressure of laser light will be used to position the bubble at the acoustic velocity node of the ultrasonic standing wave. Laser light will also be used to push the bubble away from the velocity node, increasing the effective buoyancy. The original experiments on the optical levitation and radiation pressure on bubbles in water by Unger and Marston noted above were carried out using a continuous wave (CW) beam of an Argon laser. For lateral stability the beam had a intensity minimum along its axis. Calculations of the optical radiation force on an SBSL bubble indicate that ion laser technology is a poor choice for providing the magnitude of the average optical radiation force required. Consequently it is necessary to examine various diode-pumped solid state laser technologies. The approach for this part of the research will be to achieve optical levitation of a quiescent bubble based on contemporary laser technology and then to strobe the laser synchronously with the SBSL bubble oscillations.
Lin, Shang-Lun; Wu, Shang-Liang; Ko, Shun-Yao; Lu, Ching-Hsiang; Wang, Diew-Wei; Ben, Ren-Jy; Horng, Chi-Ting; Yang, Jung-Wu
2016-07-01
Numerous studies have investigated the relationship between depression and temporomandibular disorders (TMD), but the conclusions remain vague. The aim of this study was to examine the causal effect between depression and TMD.The reporting of this study conforms to the STROBE statement. In this retrospective cohort study, all samples were recruited from a representative subdataset of 1 million insured persons for the year 2005 Longitudinal Health Insurance Database, who were randomly selected from all beneficiaries enrolled in the National Health Insurance program of Taiwan. We used a propensity score and stratified 926,560 patients into 2 groups (propensity1 = 588,429 and propensity2 = 338,131) and 4 cohorts (propensity1 with depression = 18,038, propensity1 without depression = 570,391, propensity2 with depression = 38,656, propensity2 without depression = 299,475) to detect the development of TMD among the depressive and nondepressive patients between 2004 and 2013.The positive correlative factors of TMD included female, total number of times seeking medical advice (TTSMA) for anxiety state, TTSMA for generalized anxiety disorder, TTSMA for mandible fracture, and TTSMA for unspecified anomaly of jaw size. The propensity2 group was represented by elder and female-predominant patients who used more psychiatric health resources. Among 3 types of depression, only dysthymia (so-called chronic depression) had a causal impact on TMD in the propensity 2 group. In the propensity 2 group, the hazard ratio of dysthymia for TMD measured by Cox's regression was 1.64 (95% confidence interval 1.28-2.09), after adjusting for demographic factors, psychiatric comorbidities, and maxillofacial confounders. The first-onset mean time of TMD as the consequence of dysthymia was 3.56 years (sd = 2.74, min = 0.08, median = 2.99, max = 9.73).This study demonstrates that dysthymia increases the risk of TMD in elderly and female-predominant patients who use more psychiatric health resources.
Active sampling technique to enhance chemical signature of buried explosives
NASA Astrophysics Data System (ADS)
Lovell, John S.; French, Patrick D.
2004-09-01
Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.
Target-type probability combining algorithms for multisensor tracking
NASA Astrophysics Data System (ADS)
Wigren, Torbjorn
2001-08-01
Algorithms for the handing of target type information in an operational multi-sensor tracking system are presented. The paper discusses recursive target type estimation, computation of crosses from passive data (strobe track triangulation), as well as the computation of the quality of the crosses for deghosting purposes. The focus is on Bayesian algorithms that operate in the discrete target type probability space, and on the approximations introduced for computational complexity reduction. The centralized algorithms are able to fuse discrete data from a variety of sensors and information sources, including IFF equipment, ESM's, IRST's as well as flight envelopes estimated from track data. All algorithms are asynchronous and can be tuned to handle clutter, erroneous associations as well as missed and erroneous detections. A key to obtain this ability is the inclusion of data forgetting by a procedure for propagation of target type probability states between measurement time instances. Other important properties of the algorithms are their abilities to handle ambiguous data and scenarios. The above aspects are illustrated in a simulations study. The simulation setup includes 46 air targets of 6 different types that are tracked by 5 airborne sensor platforms using ESM's and IRST's as data sources.
Fang, Chenglong; Luo, Tingting; Lin, Ling
2017-12-01
We investigated whether serum CXC ligand 13 protein (CXCL13) levels correlate with the circulating plasmablasts and memory B-cells alteration in systemic lupus erythematosus (SLE) patients. The diagnostic use of CXCL13 concentrations in active lupus was also analyzed.A total of 36 SLE patients and 18 healthy controls were included. Serum CXCL13 levels were examined by enzyme-linked immunosorbent assay. The frequency and absolute count of circulating plasmablasts and memory B cells were analyzed by flow cytometry. Receiver operating characteristic curves (ROC curves) were generated to analyze the utility of serum CXCL13 level and plasmablasts frequency as tools for the recognition of active SLE.Elevation of serum CXCL13 levels, higher plasmablasts frequency, and reduction of memory B-cells count were observed in SLE patients, compared with healthy controls. Interestingly, correlational analyses showed not only significantly positive association between CXCL13 levels and SLE Disease Activity Index (SLEDAI) or plasmablasts frequency, but an inverse correlation between CXCL13 concentration and memory B-cell count. ROC curves showed that serum CXCL13 level and plasmablasts frequency were practical in identifying active disease from overall SLE patients, with considerable accuracy.Serum CXCL13 levels correlate with the alteration of plasmablasts and memory B cells in SLE. CXCL13 may be used as a practical tool in judgment of active SLE.
NASA Tech Briefs, January 2014
NASA Technical Reports Server (NTRS)
2014-01-01
Topics include: Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity; Software Suite to Support In-Flight Characterization of Remote Sensing Systems; Visual Image Sensor Organ Replacement; Ultra-Wideband, Dual-Polarized, Beam-Steering P-Band Array Antenna; Centering a DDR Strobe in the Middle of a Data Packet; Using a Commercial Ethernet PHY Device in a Radiation Environment; Submerged AUV Charging Station; Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat; Origami-Inspired Folding of Thick, Rigid Panels; A Novel Protocol for Decoating and Permeabilizing Bacterial Spores for Epifluorescent Microscopy; Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples; Enabling Microliquid Chromatography by Microbead Packing of Microchannels; On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF; Deployable Fresnel Rings; Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics; Spacecraft Trajectory Analysis and Mission Planning Simulation (STAMPS) Software; Cross Support Transfer Service (CSTS) Framework Library; Arbitrary Shape Deformation in CFD Design; Range Safety Flight Elevation Limit Calculation Software; Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors; Calculation of Operations Efficiency Factors for Mars Surface Missions; GPU Lossless Hyperspectral Data Compression System; Robust, Optimal Subsonic Airfoil Shapes; Protograph-Based Raptor-Like Codes; Fuzzy Neuron: Method and Hardware Realization; Kalman Filter Input Processor for Boresight Calibration; Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression; and Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption.
Alarm bells ring: suicide among Chinese physicians: A STROBE compliant study.
Wang, Yu; Liu, Lei; Xu, Hongbin
2017-08-01
To our surprise, there were 2 Chinese doctors who committed suicide in the last 2 months. What are the reasons for more and more Chinese doctors to commit suicide?We present 18 cases of China's physicians who committed suicide.We summarized the main reasons for the suicide of Chinese doctors from 2004 to 2017, and the main causes included clinical working stress, Job title promotion requirements stress, tension between the doctors and patients, and shying away from necessary treatment of their illness.It is a cruel fact that more and more physicians died of suicide in China. We hope that suicide among Chinese doctors could be recognized so that it could be concerned with the understanding of human societies.
NASA Astrophysics Data System (ADS)
Caress, D. W.; Hobson, B.; Thomas, H. J.; Henthorn, R.; Martin, E. J.; Bird, L.; Rock, S. M.; Risi, M.; Padial, J. A.
2013-12-01
The Monterey Bay Aquarium Research Institute is developing a low altitude, high-resolution seafloor mapping capability that combines multibeam sonar with stereo photographic imagery. The goal is to obtain spatially quantitative, repeatable renderings of the seafloor with fidelity at scales of 5 cm or better from altitudes of 2-3 m. The initial test surveys using this sensor system are being conducted from a remotely operated vehicle (ROV). Ultimately we intend to field this survey system from an autonomous underwater vehicle (AUV). This presentation focuses on the current sensor configuration, methods for data processing, and results from recent test surveys. Bathymetry data are collected using a 400-kHz Reson 7125 multibeam sonar. This configuration produces 512 beams across a 135° wide swath; each beam has a 0.5° acrosstrack by 1.0° alongtrack angular width. At a 2-m altitude, the nadir beams have a 1.7-cm acrosstrack and 3.5 cm alongtrack footprint. Dual Allied Vision Technology GX1920 2.8 Mpixel color cameras provide color stereo photography of the seafloor. The camera housings have been fitted with corrective optics achieving a 90° field of view through a dome port. Illumination is provided by dual 100J xenon strobes. Position, depth, and attitude data are provided by a Kearfott SeaDevil Inertial Navigation System (INS) integrated with a 300 kHz RDI Doppler velocity log (DVL). A separate Paroscientific pressure sensor is mounted adjacent to the INS. The INS Kalman filter is aided by the DVL velocity and pressure data, achieving navigational drift rates less than 0.05% of the distance traveled during surveys. The sensors are mounted onto a toolsled fitted below MBARI's ROV Doc Ricketts with the sonars, cameras and strobes all pointed vertically down. During surveys the ROV flies at a 2-m altitude at speeds of 0.1-0.2 m/s. During a four-day R/V Western Flyer cruise in June 2013, we successfully collected multibeam and camera survey data from a 2-m altitude at three sites in the deep Monterey Canyon axis. The surveys lines were spaced 1.5-m and were flown at speeds of 0.1-0.2-m/s while the sonars pinged at 3 Hz and the cameras operated at 0.5 Hz. All three low-altitude surveys are at ~2850 m depth and lie within the 1-m lateral resolution bathymetry of a 2009, 50-m altitude MBARI Mapping AUV survey. Site 1 has the greatest topography, being centered on a 15 m diameter, 7 m high flat boulder surrounded by an 80 m diameter, 6 m deep scour pit. Site 2 is located within a field of ~3-m high apparent sediment waves with ~80-m wavelengths. Site 0 is flat and includes chemosynthetic clam communities. At a 2 m altitude, the multibeam bathymetry swath is more than 7 m wide and the camera images are 4 m wide. Following navigation adjustment to match features in overlapping bathymetry swaths, we achieve 5-cm lateral resolution topography overlain with ~1-mm scale photographic imagery.
Akram, Harith; Mirza, Bilal; Kitchen, Neil; Zakrzewska, Joanna M
2013-09-01
The aim of this study was to design a checklist with a scoring system for reporting on studies of surgical interventions for trigeminal neuralgia (TN) and to validate it by a review of the recent literature. A checklist with a scoring system, the Surgical Trigeminal Neuralgia Score (STNS), was devised partially based on the validated STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) criteria and customized for TN after a literature review and then applied to a series of articles. These articles were identified using a prespecified MEDLINE and Embase search covering the period from 2008 to 2010. Of the 584 articles found, 59 were studies of interventional procedures for TN that fulfilled the inclusion criteria and 56 could be obtained in full. The STNS was then applied independently by 3 of the authors. The maximum STNS came to 30, and was reliable and reproducible when used by the 3 authors who performed the scoring. The range of scores was 6-23.5, with a mean of 14 for all the journals. The impact factor scores of the journals in which the papers were published ranged from 0 to 4.8. Twenty-four of the studies were published in the Journal of Neurosurgery or in Neurosurgery. Studies published in neurosurgical journals ranked higher on the STNS scale than those published in nonneurosurgical journals. There was no statistically significant correlation between STNS and impact factors. Stereotactic radiosurgery (n = 25) and microvascular decompression (n = 15) were the most commonly reported procedures. The diagnostic criteria were stated in 35% of the studies, and 4 studies reported subtypes of TN. An increasing number of studies (46%) used the recommended Kaplan-Meier methodology for pain survival outcomes. The follow-up period was unclear in 8 studies, and 26 reported follow-ups of more than 5 years. Complications were reported fairly consistently but the temporal course was not always indicated. Direct interview, telephone conversation, and questionnaires were used to measure outcomes. Independent assessment of outcome was only clearly stated in 7 studies. Only 2 studies used the 36-Item Short Form Health Survey to measure quality of life and 4 studies reported on the severity of preoperative pain. The Barrow Neurological Institute pain questionnaire was the most commonly used outcome measure (n = 13), followed by the visual analog scale. Similar to the STROBE criteria that provide a checklist of items that should be included in reports of observational studies in general, the authors' suggested checklist for the STNS could help editors and reviewers ensure that quality reports are published, and could prove useful for colleagues when reporting their results specifically on the surgical management of TN. It would help the patient and clinicians make a decision about selecting the appropriate neurosurgical procedure.
Bennett, Greer A; Palliser, Hannah K; Shaw, Julia C; Palazzi, Kerrin L; Walker, David W; Hirst, Jonathan J
2017-11-01
Prenatal stress predisposes offspring to behavioral pathologies. These may be attributed to effects on cerebellar neurosteroids and GABAergic inhibitory signaling, which can be linked to hyperactivity disorders. The aims were to determine the effect of prenatal stress on markers of cerebellar development, a key enzyme in neurosteroid synthesis and the expression of GABA A receptor (GABA A R) subunits involved in neurosteroid signaling. We used a model of prenatal stress (strobe light exposure, 2 h on gestational day 50, 55, 60 and 65) in guinea pigs, in which we have characterized anxiety and neophobic behavioral outcomes. The cerebellum and plasma were collected from control and prenatally stressed offspring at term (control fetus: n = 9 male, n = 7 female; stressed fetus: n = 7 male, n = 8 female) and postnatal day (PND) 21 (control: n = 8 male, n = 8 female; stressed: n = 9 male, n = 6 female). We found that term female offspring exposed to prenatal stress showed decreased expression of mature oligodendrocytes (∼40% reduction) and these deficits improved to control levels by PND21. Reactive astrocyte expression was lower (∼40% reduction) following prenatal stress. GABA A R subunit (δ and α6) expression and circulating allopregnanolone concentrations were not affected by prenatal stress. Prenatal stress increased expression (∼150-250% increase) of 5α-reductase type-1 mRNA in the cerebellum, which may be a neuroprotective response to promote GABAergic inhibition and aid in repair. These observations indicate that prenatal stress exposure has marked effects on the development of the cerebellum. These findings suggest cerebellar changes after prenatal stress may contribute to adverse behavioral outcomes after exposure to these stresses.
Informing Rodent Behavior in Space: Gene Expression and Hyper-Emotionality Following Prenatal Stress
NASA Technical Reports Server (NTRS)
Moyer, E. L.; Talyansky, Y.; Baer, L. A.; Ronca, A. E.
2017-01-01
As space exploration pushes our boundaries further away from Earth and for longer durations, we will inevitably require the use of multi-generational studies to continue our expansion. Space is a stressful environment not only due to the deleterious effect of spaceflight on physiology, but also due to confinement, limited social interactions, inherently dangerous circumstances, and many other stresses of an unknown environment. Stress can alter the brain chemistry, and these alterations can affect behavior at all stages of development, but it is especially pronounced during the perinatal period and can have longstanding effects, even into adulthood, which manifest through augmented brain function and psychopathology. This study investigated the nexus of brain chemistry and brain function by observing behavior of adult rats whose mothers were exposed to unpredictable variable prenatal stress (UVPS) while they were in the womb. The UVPS consisted of strobe light, tube restraint, and white noise, and was administered at unpredictable times of the day and also varied in length, both of which were measures taken to prevent habituation to the stressor. The offspring rats were then allowed to reach adulthood and at 90 days were subjected to a series of behavioral tests including novel object, startle response, and an unknown intruder to quantify the adult rats stress response and anxiety. Here we report these results of the behavioral analysis and correlate adult behavioral measures with the expression of genes involved in the hypothalamic-pituitary-adrenal axis, which modulates the animals stress response. We hypothesized that hyper-expression of genes involved in the HPA axis would correlate with the observed anxiety-like behaviors associated with early stress.
Cavigelli, Sonia A; Bao, Alexander D; Bourne, Rebecca A; Caruso, Michael J; Caulfield, Jasmine I; Chen, Mary; Smyth, Joshua M
2018-04-12
Chronic mild stress can lead to negative health outcomes. Frequency, duration, and intensity of acute stressors can affect health-related processes. We tested whether the temporal pattern of daily acute stressors (clustered or dispersed across the day) affects depression-related physiology. We used a rodent model to keep stressor frequency, duration, and intensity constant, and experimentally manipulated the temporal pattern of acute stressors delivered during the active phase of the day. Adult male Sprague-Dawley rats were exposed to one of three chronic mild stress groups: Clustered: stressors that occurred within 1 hour of each other (n = 21), Dispersed: stressors that were spread out across the active phase (n = 21), and Control: no stressors presented (n = 21). Acute mild stressors included noise, strobe lights, novel cage, cage tilt, wet bedding, and water immersion. Depression-related outcomes included: sucrose preference, body weight, circulating glucocorticoid (corticosterone) concentration after a novel acute stressor and during basal morning and evening times, and endotoxin-induced circulating interleukin-6 concentrations. Compared to control rats, those in the Clustered group gained less weight, consumed less sucrose, had a blunted acute corticosterone response, and an accentuated acute interleukin-6 response. Rats in the Dispersed group had an attenuated corticosterone decline during the active period and after an acute stressor compared to the Control group. During a chronic mild stress experience, the temporal distribution of daily acute stressors affected health-related physiologic processes. Regular exposure to daily stressors in rapid succession may predict more depression-related symptoms, whereas exposure to stressors dispersed throughout the day may predict diminished glucocorticoid negative feedback.
Review of research designs and statistical methods employed in dental postgraduate dissertations.
Shirahatti, Ravi V; Hegde-Shetiya, Sahana
2015-01-01
There is a need to evaluate the quality of postgraduate dissertations of dentistry submitted to university in the light of the international standards of reporting. We conducted the review with an objective to document the use of sampling methods, measurement standardization, blinding, methods to eliminate bias, appropriate use of statistical tests, appropriate use of data presentation in postgraduate dental research and suggest and recommend modifications. The public access database of the dissertations from Rajiv Gandhi University of Health Sciences was reviewed. Three hundred and thirty-three eligible dissertations underwent preliminary evaluation followed by detailed evaluation of 10% of randomly selected dissertations. The dissertations were assessed based on international reporting guidelines such as strengthening the reporting of observational studies in epidemiology (STROBE), consolidated standards of reporting trials (CONSORT), and other scholarly resources. The data were compiled using MS Excel and SPSS 10.0. Numbers and percentages were used for describing the data. The "in vitro" studies were the most common type of research (39%), followed by observational (32%) and experimental studies (29%). The disciplines conservative dentistry (92%) and prosthodontics (75%) reported high numbers of in vitro research. Disciplines oral surgery (80%) and periodontics (67%) had conducted experimental studies as a major share of their research. Lacunae in the studies included observational studies not following random sampling (70%), experimental studies not following random allocation (75%), not mentioning about blinding, confounding variables and calibrations in measurements, misrepresenting the data by inappropriate data presentation, errors in reporting probability values and not reporting confidence intervals. Few studies showed grossly inappropriate choice of statistical tests and many studies needed additional tests. Overall observations indicated the need to comply with standard guidelines of reporting research.
Myosin 6 is required for iris development and normal function of the outer retina.
Samuels, Ivy S; Bell, Brent A; Sturgill-Short, Gwen; Ebke, Lindsey A; Rayborn, Mary; Shi, Lanying; Nishina, Patsy M; Peachey, Neal S
2013-11-01
To determine the molecular basis and the pathologic consequences of a chemically induced mutation in the translational vision research models 89 (tvrm89) mouse model with ERG defects. Mice from a G3 N-ethyl-N-nitrosourea mutagenesis program were screened for behavioral abnormalities and defects in retinal function by ERGs. The chromosomal position for the recessive tvrm89 mutation was determined in a genome-wide linkage analysis. The critical region was refined, and candidate genes were screened by direct sequencing. The tvrm89 phenotype was characterized by circling behavior, in vivo ocular imaging, detailed ERG-based studies of the retina and RPE, and histological analysis of these structures. The tvrm89 mutation was localized to a region on chromosome 9 containing Myo6. Sequencing identified a T→C point mutation in the codon for amino acid 480 in Myo6 that converts a leucine to a proline. This mutation does not confer a loss of protein expression levels; however, mice homozygous for the Myo6(tvrm89) mutation display an abnormal iris shape and attenuation of both strobe-flash ERGs and direct-current ERGs by 4 age weeks, neither of which is associated with photoreceptor loss. The tvrm89 phenotype mimics that reported for Myosin6-null mice, suggesting that the mutation confers a loss of myosin 6 protein function. The observation that homozygous Myo6(tvrm89) mice display reduced ERG a-wave and b-wave components, as well as components of the ERG attributed to RPE function, indicates that myosin 6 is necessary for the generation of proper responses of the outer retina to light.
Pyrotechnic whistle technology enhancements to law enforcement applications
NASA Astrophysics Data System (ADS)
Domanico, Joseph A.; Thomas, Terry E.
1998-12-01
In the past several years, there has been increasing interest in acoustic technology for less-than-lethal applications. Pyrotechnic whistles have been under study at the Edgewood Research, Development and engineering Center for several years for similar applications. Improvements in safety and handling, combined with increased levels of acoustic output, make the properly designed pyrotechnic whistle a valuable addition (read augmentation) to some current device designs. Either alone or in combination with other distraction effects, such as multiple concussion, strobing pyrotechnic, or microstarts, the pyrotechnic whistle family of devices provide a high level of target reaction with a minimum of collateral damage. This paper will summarize the recent research and development efforts in pyrotechnic whistle compositions, and the capabilities for the application of pyrotechnic whistles for typical law enforcement applications.
A meta-analysis of avascular necrosis in systemic lupus erythematosus: prevalence and risk factors.
Nevskaya, Tatiana; Gamble, Maeve P; Pope, Janet E
2017-01-01
To determine the prevalence of and risk factors for avascular necrosis (AVN) in systemic lupus erythematosus (SLE). MEDLINE, CINAHL, Web of Science, EMBASE and Cochrane Library were searched from inception to July, 2015 and a random effects model was used to combine frequencies; study quality was assessed using STROBE. 2,041 citations identified 62 articles. Many results had high heterogeneity. The prevalence of symptomatic AVN was 9% (range 0.8%-33%) in SLE and 29% for asymptomatic AVN; femoral head was the most common location (8.0%). High-dose corticosteroids (CS) any CS use, maximum and cumulative dose, pulse therapy, and CS side-effects (hypertension, Cushings, but not diabetes mellitus or hyperlipidaemia) were associated with AVN, as was active SLE (cutaneous vasculitis, renal and neuropsychiatric manifestations, serositis, cytopenias) and Sjögren's, Raynaud's phenomenon, arthritis, cyclophosphamide (but not azathioprine mycophenolate mofetil, or methotrexate) and more damage (excluding musculoskeletal system). Antimalarial drugs were not protective. Rashes and oral ulcers were not associated with AVN. Mean daily dose of CS and duration of CS use had no impact on AVN occurence. Autoantibodies and other immunological markers did not predispose to AVN, except IgM anticardiolipin antibodies which doubled the risk. African Americans experienced more AVN (OR 1.8, p=0.04). AVN may occur in 1/3 of patients with SLE and 9% with symptoms. Features of active organ SLE (CNS, renal, cutaneous vasculitis, serositis, cytopenias) are associated with AVN as are CS, especially early in disease and at high doses. Those with early CS side-effects seem to have the highest risk of AVN.
Method and reporting quality in health professions education research: a systematic review.
Cook, David A; Levinson, Anthony J; Garside, Sarah
2011-03-01
Studies evaluating reporting quality in health professions education (HPE) research have demonstrated deficiencies, but none have used comprehensive reporting standards. Additionally, the relationship between study methods and effect size (ES) in HPE research is unknown. This review aimed to evaluate, in a sample of experimental studies of Internet-based instruction, the quality of reporting, the relationship between reporting and methodological quality, and associations between ES and study methods. We conducted a systematic search of databases including MEDLINE, Scopus, CINAHL, EMBASE and ERIC, for articles published during 1990-2008. Studies (in any language) quantifying the effect of Internet-based instruction in HPE compared with no intervention or other instruction were included. Working independently and in duplicate, we coded reporting quality using the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement, and coded study methods using a modified Newcastle-Ottawa Scale (m-NOS), the Medical Education Research Study Quality Instrument (MERSQI), and the Best Evidence in Medical Education (BEME) global scale. For reporting quality, articles scored a mean±standard deviation (SD) of 51±25% of STROBE elements for the Introduction, 58±20% for the Methods, 50±18% for the Results and 41±26% for the Discussion sections. We found positive associations (all p<0.0001) between reporting quality and MERSQI (ρ=0.64), m-NOS (ρ=0.57) and BEME (ρ=0.58) scores. We explored associations between study methods and knowledge ES by subtracting each study's ES from the pooled ES for studies using that method and comparing these differences between subgroups. Effect sizes in single-group pretest/post-test studies differed from the pooled estimate more than ESs in two-group studies (p=0.013). No difference was found between other study methods (yes/no: representative sample, comparison group from same community, randomised, allocation concealed, participants blinded, assessor blinded, objective assessment, high follow-up). Information is missing from all sections of reports of HPE experiments. Single-group pre-/post-test studies may overestimate ES compared with two-group designs. Other methodological variations did not bias study results in this sample. © Blackwell Publishing Ltd 2011.
West, Matthew; Chuter, Vivienne; Munteanu, Shannon; Hawke, Fiona
2017-01-01
The Aboriginal and Torres Strait Islander community has an increased risk of developing chronic illnesses including diabetes. Among people with diabetes, foot complications are common and make a significant contribution to the morbidity and mortality associated with this disease. The aim of this review was to systematically evaluate the literature comparing the rates of diabetes related foot complications in Aboriginal and Torres Strait Islander Australians to non-Indigenous Australians. MEDLINE, EMBASE, The Cochrane Library; PUBMED and CINAHL were searched from inception until August 2016. Inclusion criteria were: published cross-sectional or longitudinal studies reporting the prevalence of diabetes related foot complications in both a cohort of Aboriginal and Torres Strait Islander Australians and a cohort of one other Australian population of any age with diabetes. Risk of bias was assessed using the STROBE tool. Eleven studies including a total of 157,892 participants were included. Studies were set in Queensland, the Northern Territory and Western Australia, primarily in rural and remote areas. Aboriginal and Torres Strait Islander Australians experienced substantially more diabetes related foot complications with the mean age up to 14 years younger than non-Indigenous Australians. Aboriginality was associated with increased risk of peripheral neuropathy, foot ulceration and amputation. In several studies, Aboriginal and Torres Strait Islander Australians accounted for the vast majority of diabetes related foot complications (up to 91%) while comprising only a small proportion of the regional population. Reporting quality as assessed with the STROBE tool showed underreporting of: methods, sample description and potential sources of bias. There are no data available for some Australian states and for specific types of diabetes related foot complications. Aboriginal and Torres Strait Islander Australians have a 3-6 fold increased likelihood of experiencing a diabetes related foot complication compared to non-Indigenous Australians. Evidence-based, culturally appropriate screening and intervention programs and improved access to effective health care services are required to prevent a widening of the gap in diabetes related foot complications between Aboriginal and Torres Strait Islander and non-Indigenous Australians.
Reporting guidelines for primary research: Saying what you did.
O'Connor, Annette
2010-12-01
Reporting guidelines aim to facilitate publication of a full and accurate description of research conducted. The motivations for a full and accurate description of research is to enable reproduction of the study, assessment of bias, extraction of data from the study, and to fulfill an ethical obligation to maximize the utility of research findings. Many reporting guidelines exist and most are based on a specific study design such as randomized controlled trials (CONSORT statement) and observational studies (STROBE statement). The REFLECT statement focuses on randomized control trials in livestock and food safety studies. The REFLECT statement has increased emphasis on conveying information about animal housing, group level allocation and challenge studies. Guidelines can be used by authors, reviewers and editors to provide readers with a full and accurate description of the work conducted. Copyright © 2010 Elsevier B.V. All rights reserved.
Circuit design for the retina-like image sensor based on space-variant lens array
NASA Astrophysics Data System (ADS)
Gao, Hongxun; Hao, Qun; Jin, Xuefeng; Cao, Jie; Liu, Yue; Song, Yong; Fan, Fan
2013-12-01
Retina-like image sensor is based on the non-uniformity of the human eyes and the log-polar coordinate theory. It has advantages of high-quality data compression and redundant information elimination. However, retina-like image sensors based on the CMOS craft have drawbacks such as high cost, low sensitivity and signal outputting efficiency and updating inconvenience. Therefore, this paper proposes a retina-like image sensor based on space-variant lens array, focusing on the circuit design to provide circuit support to the whole system. The circuit includes the following parts: (1) A photo-detector array with a lens array to convert optical signals to electrical signals; (2) a strobe circuit for time-gating of the pixels and parallel paths for high-speed transmission of the data; (3) a high-precision digital potentiometer for the I-V conversion, ratio normalization and sensitivity adjustment, a programmable gain amplifier for automatic generation control(AGC), and a A/D converter for the A/D conversion in every path; (4) the digital data is displayed on LCD and stored temporarily in DDR2 SDRAM; (5) a USB port to transfer the data to PC; (6) the whole system is controlled by FPGA. This circuit has advantages as lower cost, larger pixels, updating convenience and higher signal outputting efficiency. Experiments have proved that the grayscale output of every pixel basically matches the target and a non-uniform image of the target is ideally achieved in real time. The circuit can provide adequate technical support to retina-like image sensors based on space-variant lens array.
A fast-locking all-digital delay-locked loop for phase/delay generation in an FPGA
NASA Astrophysics Data System (ADS)
Zhujia, Chen; Haigang, Yang; Fei, Liu; Yu, Wang
2011-10-01
A fast-locking all-digital delay-locked loop (ADDLL) is proposed for the DDR SDRAM controller interface in a field programmable gate array (FPGA). The ADDLL performs a 90° phase-shift so that the data strobe (DQS) can enlarge the data valid window in order to minimize skew. In order to further reduce the locking time and to prevent the harmonic locking problem, a time-to-digital converter (TDC) is proposed. A duty cycle corrector (DCC) is also designed in the ADDLL to adjust the output duty cycle to 50%. The ADDLL, implemented in a commercial 0.13 μm CMOS process, occupies a total of 0.017 mm2 of active area. Measurement results show that the ADDLL has an operating frequency range of 75 to 350 MHz and a total delay resolution of 15 ps. The time interval error (TIE) of the proposed circuit is 60.7 ps.
Glujovsky, Demián; Villanueva, Eleana; Reveiz, Ludovic; Murasaki, Renato
2014-10-01
To evaluate the familiarity of the editors of journals indexed in the LILACS database with the guidelines for reporting on and publishing research- promoted by the EQUATOR Network (Enhancing QUAlity and Transparency Of Health Research)-, the journals' requirements for use of the guidelines, and the editors' opinions regarding the reasons for the low rate of use. LILACS editors were surveyed by e-mail about the guidelines and their availability at the EQUATOR website, and about the requirements and difficulties in using them. Of 802 editors, 16.4% answered the survey. More than half said they were not aware of the guidelines (especially STROBE and PRISMA) and 30% were familiar with the EQUATOR Network. The first Latin American and Caribbean study on LILACS editors' familiarity with the guidelines revealed that more than half of them were not familiar either with the guidelines or the EQUATOR Network.
NASA Astrophysics Data System (ADS)
2006-01-01
WE RECOMMEND GLX Xplorer Datalogger This hand-held device offers great portability and robustness. Theoretical Concepts in Physics A first-rate reference tool for physics teachers. Do Your Ears Pop in Space? This little gem gives a personal insight into space travel. Full Moon A collection of high-quality photographs from the Apollo missions. The Genius of Science A collection of memories from leading 20th-century physicists. The Simple Science of Flight An excellent source of facts and figures about flight. SUREHigherPhysics This simulation-based software complies with Higher physics. Interactive Physics A programme that makes building simulations quick and easy. WORTH A LOOK Astronomical Enigmas This guide to enigmas could be a little shorter. HANDLE WITH CARE Standing-wave machine This is basically a standing-wave generator with a built-in strobe. WEB WATCH Sounds Amazing is a fantastic site, aimed at Key Stage 4 pupils, for learning about sound and waves.
Piezoelectric trace vapor calibrator
NASA Astrophysics Data System (ADS)
Verkouteren, R. Michael; Gillen, Greg; Taylor, David W.
2006-08-01
The design and performance of a vapor generator for calibration and testing of trace chemical sensors are described. The device utilizes piezoelectric ink-jet nozzles to dispense and vaporize precisely known amounts of analyte solutions as monodisperse droplets onto a hot ceramic surface, where the generated vapors are mixed with air before exiting the device. Injected droplets are monitored by microscope with strobed illumination, and the reproducibility of droplet volumes is optimized by adjustment of piezoelectric wave form parameters. Complete vaporization of the droplets occurs only across a 10°C window within the transition boiling regime of the solvent, and the minimum and maximum rates of trace analyte that may be injected and evaporated are determined by thermodynamic principles and empirical observations of droplet formation and stability. By varying solution concentrations, droplet injection rates, air flow, and the number of active nozzles, the system is designed to deliver—on demand—continuous vapor concentrations across more than six orders of magnitude (nominally 290fg/lto1.05μg/l). Vapor pulses containing femtogram to microgram quantities of analyte may also be generated. Calibrated ranges of three explosive vapors at ng/l levels were generated by the device and directly measured by ion mobility spectrometry (IMS). These data demonstrate expected linear trends within the limited working range of the IMS detector and also exhibit subtle nonlinear behavior from the IMS measurement process.
Guglielminotti, Jean; Dechartres, Agnès; Mentré, France; Montravers, Philippe; Longrois, Dan; Laouénan, Cedric
2015-10-01
Prognostic research studies in anesthesiology aim to identify risk factors for an outcome (explanatory studies) or calculate the risk of this outcome on the basis of patients' risk factors (predictive studies). Multivariable models express the relationship between predictors and an outcome and are used in both explanatory and predictive studies. Model development demands a strict methodology and a clear reporting to assess its reliability. In this methodological descriptive review, we critically assessed the reporting and methodology of multivariable analysis used in observational prognostic studies published in anesthesiology journals. A systematic search was conducted on Medline through Web of Knowledge, PubMed, and journal websites to identify observational prognostic studies with multivariable analysis published in Anesthesiology, Anesthesia & Analgesia, British Journal of Anaesthesia, and Anaesthesia in 2010 and 2011. Data were extracted by 2 independent readers. First, studies were analyzed with respect to reporting of outcomes, design, size, methods of analysis, model performance (discrimination and calibration), model validation, clinical usefulness, and STROBE (i.e., Strengthening the Reporting of Observational Studies in Epidemiology) checklist. A reporting rate was calculated on the basis of 21 items of the aforementioned points. Second, they were analyzed with respect to some predefined methodological points. Eighty-six studies were included: 87.2% were explanatory and 80.2% investigated a postoperative event. The reporting was fairly good, with a median reporting rate of 79% (75% in explanatory studies and 100% in predictive studies). Six items had a reporting rate <36% (i.e., the 25th percentile), with some of them not identified in the STROBE checklist: blinded evaluation of the outcome (11.9%), reason for sample size (15.1%), handling of missing data (36.0%), assessment of colinearity (17.4%), assessment of interactions (13.9%), and calibration (34.9%). When reported, a few methodological shortcomings were observed, both in explanatory and predictive studies, such as an insufficient number of events of the outcome (44.6%), exclusion of cases with missing data (93.6%), or categorization of continuous variables (65.1%.). The reporting of multivariable analysis was fairly good and could be further improved by checking reporting guidelines and EQUATOR Network website. Limiting the number of candidate variables, including cases with missing data, and not arbitrarily categorizing continuous variables should be encouraged.
Einarson, Thomas R; Acs, Annabel; Ludwig, Craig; Panton, Ulrik H
2018-06-08
Cardiovascular disease (CVD) is a common comorbidity in type 2 diabetes (T2DM). CVD's prevalence has been growing over time. To estimate the current prevalence of CVD among adults with T2DM by reviewing literature published within the last 10 years (2007-March 2017). We searched Medline, Embase, and proceedings of major scientific meetings for original research documenting the prevalence of CVD in T2DM. CVD included stroke, myocardial infarction, angina pectoris, heart failure, ischemic heart disease, cardiovascular disease, coronary heart disease, atherosclerosis, and cardiovascular death. No restrictions were placed on country of origin or publication language. Two reviewers independently searched for articles and extracted data, adjudicating results through consensus. Data were summarized descriptively. Risk of bias was examined by applying the STROBE checklist. We analyzed data from 57 articles with 4,549,481 persons having T2DM. Europe produced the most articles (46%), followed by the Western Pacific/China (21%), and North America (13%). Overall in 4,549,481 persons with T2DM, 52.0% were male, 47.0% were obese, aged 63.6 ± 6.9 years old, with T2DM duration of 10.4 ± 3.7 years. CVD affected 32.2% overall (53 studies, N = 4,289,140); 29.1% had atherosclerosis (4 studies, N = 1153), 21.2% had coronary heart disease (42 articles, N = 3,833,200), 14.9% heart failure (14 studies, N = 601,154), 14.6% angina (4 studies, N = 354,743), 10.0% myocardial infarction (13 studies, N = 3,518,833) and 7.6% stroke (39 studies, N = 3,901,505). CVD was the cause of death in 9.9% of T2DM patients (representing 50.3% of all deaths). Risk of bias was low; 80 ± 12% of STROBE checklist items were adequately addressed. Globally, overall CVD affects approximately 32.2% of all persons with T2DM. CVD is a major cause of mortality among people with T2DM, accounting for approximately half of all deaths over the study period. Coronary artery disease and stroke were the major contributors.
Visual abnormalities associated with enhanced optic nerve myelination.
Yu, Minzhong; Narayanan, S Priyadarshini; Wang, Feng; Morse, Emily; Macklin, Wendy B; Peachey, Neal S
2011-02-16
Expression of the constitutively active serine/threonine kinase Akt in oligodendrocytes results in enhanced myelination in the CNS. Here, we have examined the effects of this Akt overexpression on optic nerve structure and on optic nerve function, assessed using the visual evoked potential (VEP). Transgenic mice have been generated with the Plp promoter driving expression of a modified form of Akt, in which aspartic acids are substituted for Thr308 and Ser473. These Plp-Akt-DD (Akt-DD) mice, and littermate controls, were studied at different ages. Optic nerves were examined anatomically at 2 and 6 months of age. At 2 months of age, optic nerves were substantially thicker in Akt-DD mice, reflecting an increase in myelination of optic nerve axons. By electron microscopy, myelin thickness was increased in Akt-DD optic nerve, with extended paranodal domains having excess paranodal loops, and the density of nodes of Ranvier was reduced, relative to control mice. We recorded VEPs in response to strobe flash ganzfeld stimuli presented after overnight dark- and light-adapted conditions at ages ranging from 1 to 10 months. It was possible to record a clear VEP from Akt-DD mice at all ages examined. At 1 month of age, VEP implicit times were somewhat shorter in Akt-DD transgenic mice than in control animals. Beyond 6months of age, VEP latencies were consistently delayed in Akt-DD transgenic mice. These abnormalities did not reflect an alteration in retinal function as there were no significant differences between ERGs obtained from control or Akt-DD transgenic mice. In young mice, the somewhat faster responses may reflect improved transmission due to increased myelination of optic nerve axons. In older mice, where the Akt-DD optic nerve is markedly thicker than control, it is remarkable that optic nerves continue to function. Copyright © 2010 Elsevier B.V. All rights reserved.
14 CFR 23.1385 - Position light system installation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Position light system installation. 23.1385... Lights § 23.1385 Position light system installation. (a) General. Each part of each position light system... requirements of §§ 23.1387 through 23.1397. (b) Left and right position lights. Left and right position lights...
14 CFR 23.1385 - Position light system installation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light system installation. 23.1385... Lights § 23.1385 Position light system installation. (a) General. Each part of each position light system... requirements of §§ 23.1387 through 23.1397. (b) Left and right position lights. Left and right position lights...
14 CFR 23.1385 - Position light system installation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light system installation. 23.1385... Lights § 23.1385 Position light system installation. (a) General. Each part of each position light system... requirements of §§ 23.1387 through 23.1397. (b) Left and right position lights. Left and right position lights...
14 CFR 23.1385 - Position light system installation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light system installation. 23.1385... Lights § 23.1385 Position light system installation. (a) General. Each part of each position light system... requirements of §§ 23.1387 through 23.1397. (b) Left and right position lights. Left and right position lights...
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2015-02-24
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2015-08-25
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton; Stecher, Thomas; Seeley, Charles; Kuenzler, Glenn; Wolfe, Jr., Charles; Utturkar, Yogen; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2013-05-07
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr, Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2016-10-11
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
14 CFR 27.1401 - Anticollision light system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Anticollision light system. 27.1401 Section... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 29.1401 - Anticollision light system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Anticollision light system. 29.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 27.1401 - Anticollision light system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Anticollision light system. 27.1401 Section... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 27.1401 - Anticollision light system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Anticollision light system. 27.1401 Section... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 27.1401 - Anticollision light system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Anticollision light system. 27.1401 Section... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 29.1401 - Anticollision light system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Anticollision light system. 29.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 27.1401 - Anticollision light system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Anticollision light system. 27.1401 Section... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
14 CFR 29.1401 - Anticollision light system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Anticollision light system. 29.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1401 Anticollision light system. (a... light system that— (1) Consists of one or more approved anticollision lights located so that their...
33 CFR 127.109 - Lighting systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Lighting systems. 127.109 Section... Waterfront Facilities Handling Liquefied Natural Gas § 127.109 Lighting systems. (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting. (b) All outdoor lighting must be...
33 CFR 127.109 - Lighting systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Lighting systems. 127.109 Section... Waterfront Facilities Handling Liquefied Natural Gas § 127.109 Lighting systems. (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting. (b) All outdoor lighting must be...
33 CFR 127.109 - Lighting systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Lighting systems. 127.109 Section... Waterfront Facilities Handling Liquefied Natural Gas § 127.109 Lighting systems. (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting. (b) All outdoor lighting must be...
33 CFR 127.109 - Lighting systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Lighting systems. 127.109 Section... Waterfront Facilities Handling Liquefied Natural Gas § 127.109 Lighting systems. (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting. (b) All outdoor lighting must be...
33 CFR 127.109 - Lighting systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Lighting systems. 127.109 Section... Waterfront Facilities Handling Liquefied Natural Gas § 127.109 Lighting systems. (a) The marine transfer area for LNG must have a lighting system and separate emergency lighting. (b) All outdoor lighting must be...
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Sharma, Rajdeep
2013-12-10
Lighting system having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr, Charles Franklin; Sharma, Rajdeep
2016-08-30
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Sharma, Rajdeep
2016-08-23
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
Imaging spectrometer wide field catadioptric design
Chrisp,; Michael, P [Danville, CA
2008-08-19
A wide field catadioptric imaging spectrometer with an immersive diffraction grating that compensates optical distortions. The catadioptric design has zero Petzval field curvature. The imaging spectrometer comprises an entrance slit for transmitting light, a system with a catadioptric lens and a dioptric lens for receiving the light and directing the light, an immersion grating, and a detector array. The entrance slit, the system for receiving the light, the immersion grating, and the detector array are positioned wherein the entrance slit transmits light to the system for receiving the light and the system for receiving the light directs the light to the immersion grating and the immersion grating receives the light and directs the light through the system for receiving the light to the detector array.
Refrigerated display case lighting with LEDs
NASA Astrophysics Data System (ADS)
Raghavan, Ramesh; Narendran, Nadarajah
2002-11-01
The rapid development of high brightness light emitting diodes (LEDs) has triggered many applications, especially in the area of display lighting. This paper focuses on the application of white LEDs in refrigerated display cases. The fluorescent lighting presently used in commercial refrigerators is inefficient in the application and also it provides poor lighting for merchandising. A laboratory human factors experiment was conducted to assess the preference for the different lighting systems, namely, fluorescent and LED. Two refrigerated display cases, one with the traditional fluorescent lighting system and the other with a prototype LED lighting system, were placed side-by-side in a laboratory setting. Illuminance measurements made within the two display cases showed that the lighting was more uniform with the LED system compared to the traditional fluorescent system. Sixteen human subjects participated in this study and rated their preference for the two lighting systems. The results show that human subjects strongly preferred the display case with the LED lighting. The authors of this manuscript believe a field study would be greatly beneficial to further confirm these results and to understand the relationship between preference and sales. Considering the luminous efficacy of white LEDs presently available in the marketplace, it is possible to develop a LED based lighting system for commercial refrigerators that is competitive with fluorescent lighting system in terms of energy use. The LED based lighting would provide better lighting than traditional fluorescent lighting.
NASA Technical Reports Server (NTRS)
Watters, D. M.
1986-01-01
The operation of a radio beacon position locator during and after the remotely controlled transport aircraft is discussed. The radio beacon transmission was actuated and was picked up by the Navy P-3A chase aircraft for a short time, after which reception was lost. The pilot reported that he received a signal on both 121.5 MHz and 243 MHz for a period of approximately 5 seconds. Five minutes after the crash a portable direction finding unit located on the roof of the NASA Dryden Flight Research Facility, 4 miles distant from the crash, was unable to pick up the beacon transmission. The fire crews started fighting the fires approximately 90 seconds after the time of impact. Navy personnel access to the crash site was allowed on the morning of December 2, 1984. Radio beacon locator was found resting top side up, 15 feet forward and 13 feet perpendicular from the tray location the starboard side of the aircraft. An immediate inspection indicated the airfoil suffered moderate fire damage with paint peeling but not intumescing. The visual marker strobe lamp housings were intact but extensively burned such that it was impossible to see if the lamps had survived. The airfoil suffered minor structural damage, with assorted dents, etc. The extended plunger on the ARU-21 release unit indicated that the pyrotechnic deployment system operated. The radio beacon base (tray) suffered some heat and fire damage, and was charred and blackened by smoke. The frangible switch in the nose survived and the switch in the belly was recovered and found to have actuated. It is assumed that this switch fired the ARU-21 squib. There were no other release switches installed in the normally open system in the aircraft.
14 CFR 23.1401 - Anticollision light system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Anticollision light system. 23.1401 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that: (1) Consists...
14 CFR 27.1385 - Position light system installation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Position light system installation. 27.1385... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 29.1385 - Position light system installation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Position light system installation. 29.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 25.1385 - Position light system installation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Position light system installation. 25.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 25.1385 - Position light system installation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Position light system installation. 25.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 23.1401 - Anticollision light system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Anticollision light system. 23.1401 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that: (1) Consists...
14 CFR 29.1385 - Position light system installation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light system installation. 29.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 25.1385 - Position light system installation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light system installation. 25.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 27.1385 - Position light system installation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light system installation. 27.1385... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 29.1385 - Position light system installation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Position light system installation. 29.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 23.1401 - Anticollision light system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Anticollision light system. 23.1401 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that: (1) Consists...
14 CFR 27.1385 - Position light system installation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light system installation. 27.1385... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 27.1385 - Position light system installation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Position light system installation. 27.1385... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 25.1385 - Position light system installation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light system installation. 25.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
14 CFR 29.1385 - Position light system installation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light system installation. 29.1385... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1385 Position light system installation. (a) General. Each part of each position light system must meet the applicable...
NASA Lighting Research, Test, & Analysis
NASA Technical Reports Server (NTRS)
Clark, Toni
2015-01-01
The Habitability and Human Factors Branch, at Johnson Space Center, in Houston, TX, provides technical guidance for the development of spaceflight lighting requirements, verification of light system performance, analysis of integrated environmental lighting systems, and research of lighting-related human performance issues. The Habitability & Human Factors Lighting Team maintains two physical facilities that are integrated to provide support. The Lighting Environment Test Facility (LETF) provides a controlled darkroom environment for physical verification of lighting systems with photometric and spetrographic measurement systems. The Graphics Research & Analysis Facility (GRAF) maintains the capability for computer-based analysis of operational lighting environments. The combined capabilities of the Lighting Team at Johnson Space Center have been used for a wide range of lighting-related issues.
14 CFR 25.1401 - Anticollision light system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Anticollision light system. 25.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that— (1) Consists of one or more approved...
14 CFR 25.1401 - Anticollision light system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Anticollision light system. 25.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that— (1) Consists of one or more approved...
14 CFR 25.1401 - Anticollision light system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Anticollision light system. 25.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that— (1) Consists of one or more approved...
14 CFR 25.1401 - Anticollision light system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Anticollision light system. 25.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1401 Anticollision light system. (a) General. The airplane must have an anticollision light system that— (1) Consists of one or more approved...
Color Choice is Everything - Impacts Color makes to the Lighting Environment
NASA Technical Reports Server (NTRS)
Clark, Toni A.
2012-01-01
When contracts are let out to design multiple systems in a vehicle, it is a challenge to maintain integration between system leads. Designers on niche systems, like lighting and control panel design, often get caught up in the challenge of designing the light source or visual interface and fail to include time in their schedule to work with system architects on how their lighting system will be integrated. Additionally, behavioral scientists, industrial designers, and materials engineers get caught up with the materials and look of the system, but often fail to consider how the selection of their materials could affect the certification or performance of electronic devices like lighting systems. Additionally, computer modeling of the system architecture often assumes a perfect environment without the clutter of actual human use (dirt, stowage, crowding). As a result, lighting systems, and backlit displays run the risk of being overdesigned or under designed. Engineers making the assumption that because they have no input or there is no requirement on work surface reflectance, make the assumption that they can t count on good material choices and thus may install more lighting than is necessary. While having more lights may seem better, for a vehicle that is trying to conserve power, more lights may not be a good option. On the other hand, designers who made the opposite assumption and designed a lighting system that only produced just enough light, often wind up with a system that did conserve power, but didn t produce enough light. These situations are exasperated when the system starts to be used and the models are not perfect anymore. The lack of coordination and iterative design not only can impact lighting levels within an environment, but also can affect color perception. This is because, if materials do not represent a gradation of white or black, the material unevenly absorbs and reflects light at different wavelengths of the visual spectrum. The lighting designer may have built a light that meets light spectra requirements, but the eventual light reaching the human user may not be the spectra of light architects intended, if materials near the light source change the spectrum just by how much color is absorbed or reflected. With the recent findings concerning Circadian rhythm, where the spectra of light is extremely important for addressing crew sleep and wake cycles, system architects should pay considerable attention on the impact material choices have in changing the light spectrum in an environment. This presentation will show examples of how material choices impact the resulting illuminance, color spectrum, and power usage of an illuminated space. Its goal is to encourage system designers and planners to use more care in development of requirements and the verification of systems intended for the human visual interface.
Behzadifar, Masoud; Gorji, Hassan Abolghasem; Bragazzi, Nicola Luigi
2018-05-01
One of the major infections transmitted through the bloodstream is hepatitis C virus (HCV) infection. Patients with thalassemia requiring frequent blood transfusions are at risk for HCV. Therefore, this study was conducted to determine the incidence of HCV in thalassemia patients in Iran. The following databases were searched: ISI/Web of Science, Embase, Pubmed/MEDLINE via Ovid, Scopus, as well as Iranian databases (Magiran, Irandoc and SID) from January 2000 to July 2017. The quality of the studies was evaluated using the 22-item STROBE checklist. The random model based on the DerSimonian/Laird approach was used. To assess the stability of the results, a sensitivity analysis was performed, stratifying on the basis of quality, sample size, year of publication, and geographical area of studies. Also, meta-regression analyses were carried out in terms of sample size and year of publication of studies. Fifty-two studies were included. The total number of patients included was 13,291. Based on the random model, the overall prevalence of HCV in thalassemia patients was 19% (95% CI 16-21). The results did not differ before and after sensitivity analysis. The prevalence of HCV in thalassemia patients in Iran was 19%. This figure was lower than in the neighboring countries of Iran. Screening and the use of diagnostic methods for screening blood donors are essential. In addition, the treatment of patients should be seriously addressed by the agenda of the Iranian health system.
Bubbles in an acoustic field: an overview.
Ashokkumar, Muthupandian; Lee, Judy; Kentish, Sandra; Grieser, Franz
2007-04-01
Acoustic cavitation is the fundamental process responsible for the initiation of most of the sonochemical reactions in liquids. Acoustic cavitation originates from the interaction between sound waves and bubbles. In an acoustic field, bubbles can undergo growth by rectified diffusion, bubble-bubble coalescence, bubble dissolution or bubble collapse leading to the generation of primary radicals and other secondary chemical reactions. Surface active solutes have been used in association with a number of experimental techniques in order to isolate and understand these activities. A strobe technique has been used for monitoring the growth of a single bubble by rectified diffusion. Multibubble sonoluminescence has been used for monitoring the growth of the bubbles as well as coalescence between bubbles. The extent of bubble coalescence has also been monitored using a newly developed capillary technique. An overview of the various experimental results has been presented in order to highlight the complexities involved in acoustic cavitation processes, which on the other hand arise from a simple, mechanical interaction between sound waves and bubbles.
Wittmann, Marion E; Cooke, Roger M; Rothlisberger, John D; Lodge, David M
2014-02-18
Recently, authors have theorized that invasive species prevention is more cost-effective than control in protecting ecosystem services. However, quantification of the effectiveness of prevention is rare because experiments at field scales are expensive or infeasible. We therefore used structured expert judgment to quantify the efficacy of 17 proposed strategies to prevent Asian carp invasion of the Laurentian Great Lakes via the hydrologic connection between the Mississippi and Great Lakes watersheds. Performance-weighted expert estimates indicated that hydrologic separation would prevent 99% (95,100; median, 5th and 95th percentiles) of Asian carp access, while electric and acoustic-bubble-strobe barriers would prevent 92% (85,95) and 92% (75,95), respectively. For all other strategies, estimated effectiveness was lower, with greater uncertainty. When potential invasions by other taxa are considered, the effectiveness of hydrologic separation increases relative to strategies that are effective primarily for fishes. These results could help guide invasive species management in many waterways globally.
Accretion Disks and Coronae in the X-Ray Flashlight
NASA Astrophysics Data System (ADS)
Degenaar, Nathalie; Ballantyne, David R.; Belloni, Tomaso; Chakraborty, Manoneeta; Chen, Yu-Peng; Ji, Long; Kretschmar, Peter; Kuulkers, Erik; Li, Jian; Maccarone, Thomas J.; Malzac, Julien; Zhang, Shu; Zhang, Shuang-Nan
2018-02-01
Plasma accreted onto the surface of a neutron star can ignite due to unstable thermonuclear burning and produce a bright flash of X-ray emission called a Type-I X-ray burst. Such events are very common; thousands have been observed to date from over a hundred accreting neutron stars. The intense, often Eddington-limited, radiation generated in these thermonuclear explosions can have a discernible effect on the surrounding accretion flow that consists of an accretion disk and a hot electron corona. Type-I X-ray bursts can therefore serve as direct, repeating probes of the internal dynamics of the accretion process. In this work we review and interpret the observational evidence for the impact that Type-I X-ray bursts have on accretion disks and coronae. We also provide an outlook of how to make further progress in this research field with prospective experiments and analysis techniques, and by exploiting the technical capabilities of the new and concept X-ray missions ASTROSAT, NICER, Insight-HXMT, eXTP, and STROBE-X.
Hybrid daylight/light-emitting diode illumination system for indoor lighting.
Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei
2014-03-20
A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.
Use of diffusive optical fibers for plant lighting
NASA Technical Reports Server (NTRS)
Kozai, T.; Kitaya, Y.; Fujiwara, K.; Kino, S.; Kinowaki, M.
1994-01-01
Lighting is one of the most critical aspects in plant production and environmental research with plants. Much research has been repeated on the effect of light intensity, spectral distribution of light and lighting cycle, but comparatively little research done on the effect of lighting direction on the growth, development and morphology of plants. When plants are grown with lamps above, light is directed downward to the plants. Downward or overhead lighting is utilized in almost all cases. However, downward lighting does not always give the best result in terms of lighting efficiency, growth, development and morphology of plants. In the present study, a sideward lighting system was developed using diffusive optical fiber belts. More higher quality tissue-cultured transplants could be produced in a reduced space with the sideward lighting system than with a downward lighting system. An application of the sideward lighting system using diffusive optical fiber belts is described and the advantages and disadvantages are discussed.
Use of diffusive optical fibers for plant lighting
NASA Astrophysics Data System (ADS)
Kozai, T.; Kitaya, Y.; Fujiwara, K.; Kino, S.; Kinowaki, M.
1994-03-01
Lighting is one of the most critical aspects in plant production and environmental research with plants. Much research has been repeated on the effect of light intensity, spectral distribution of light and lighting cycle, but comparatively little research done on the effect of lighting direction on the growth, development and morphology of plants. When plants are grown with lamps above, light is directed downward to the plants. Downward or overhead lighting is utilized in almost all cases. However, downward lighting does not always give the best result in terms of lighting efficiency, growth, development and morphology of plants. In the present study, a sideward lighting system was developed using diffusive optical fiber belts. More higher quality tissue-cultured transplants could be produced in a reduced space with the sideward lighting system than with a downward lighting system. An application of the sideward lighting system using diffusive optical fiber belts is described and the advantages and disadvantages are discussed.
Computer-assisted sperm analysis (CASA): capabilities and potential developments.
Amann, Rupert P; Waberski, Dagmar
2014-01-01
Computer-assisted sperm analysis (CASA) systems have evolved over approximately 40 years, through advances in devices to capture the image from a microscope, huge increases in computational power concurrent with amazing reduction in size of computers, new computer languages, and updated/expanded software algorithms. Remarkably, basic concepts for identifying sperm and their motion patterns are little changed. Older and slower systems remain in use. Most major spermatology laboratories and semen processing facilities have a CASA system, but the extent of reliance thereon ranges widely. This review describes capabilities and limitations of present CASA technology used with boar, bull, and stallion sperm, followed by possible future developments. Each marketed system is different. Modern CASA systems can automatically view multiple fields in a shallow specimen chamber to capture strobe-like images of 500 to >2000 sperm, at 50 or 60 frames per second, in clear or complex extenders, and in <2 minutes, store information for ≥ 30 frames and provide summary data for each spermatozoon and the population. A few systems evaluate sperm morphology concurrent with motion. CASA cannot accurately predict 'fertility' that will be obtained with a semen sample or subject. However, when carefully validated, current CASA systems provide information important for quality assurance of semen planned for marketing, and for the understanding of the diversity of sperm responses to changes in the microenvironment in research. The four take-home messages from this review are: (1) animal species, extender or medium, specimen chamber, intensity of illumination, imaging hardware and software, instrument settings, technician, etc., all affect accuracy and precision of output values; (2) semen production facilities probably do not need a substantially different CASA system whereas biology laboratories would benefit from systems capable of imaging and tracking sperm in deep chambers for a flexible period of time; (3) software should enable grouping of individual sperm based on one or more attributes so outputs reflect subpopulations or clusters of similar sperm with unique properties; means or medians for the total population are insufficient; and (4) a field-use, portable CASA system for measuring one motion and two or three morphology attributes of individual sperm is needed for field theriogenologists or andrologists working with human sperm outside urban centers; appropriate hardware to capture images and process data apparently are available. Copyright © 2014 Elsevier Inc. All rights reserved.
Lighting system with heat distribution face plate
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri
2013-09-10
Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubinstein, Francis M.
Specific recommendations are made to improve the lighting quality and energy efficiency of the lighting system at the Social Security Administration Frank Hagel Building in Richmond, CA. The main recommendation is to replace the recessed fluorescent lighting system in the general office area with indirect lighting. Indirect lighting will improve lighting quality, will provide an energy efficient solution and will be about the same cost as the direct lighting system originally proposed.
HORIZONTAL HYBRID SOLAR LIGHT PIPE: AN INTEGRATED SYSTEM OF DAYLIGHT AND ELECTRIC LIGHT
This project will test the feasibility of an advanced energy efficient perimeter lighting system that integrates daylighting, electric lighting, and lighting controls to reduce electricity consumption. The system is designed to provide adequate illuminance levels in deep-floor...
Use of diffusive optical fibers for plant lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozai, T.; Kitaya, Y.; Fujiwara, K.
1994-12-31
Lighting is one of the most critical aspects in plant production and environmental research with plants. Much research has been repeated on the effect of light intensity, spectral distribution of light and lighting cycle, but comparatively little research done on the effect of lighting direction on the growth, development and morphology of plants. When plants are grown with lamps above, light is directed downward to the plants. Downward or overhead lighting is utilized in almost all cases. However, downward lighting does not always give the best result in terms of lighting efficiency, growth, development and morphology of plants. Kitaya etmore » al. (1988) developed a lighting system in which two rooting beds were arranged; one above and the other under fluorescent lamps. Lettuce plants grew normally in the lower bed and suspended upside-down under the upper bed. The lettuce plants suspended upside-down were given the light in upward direction (upward lighting). No significant difference in growth, development and morphology was found between the lettuce plants grown by the downward and upward lighting. Combining upward and downward lighting, improved spacing efficiency and reduced electricity cost per plant compared with conventional, downward lighting. From the above example, when designing a lighting system for plants with lamps more lighting direction should be considered. In the present study, a sideward lighting system was developed using diffusive optical fiber belts. More higher quality tissue-cultured transplants could be produced in reduced space with sideward lighting system than with a downward lighting system. An application of the sideward lighting system using diffusive optical fiber belts is described and advantages and disadvantages are discussed.« less
14 CFR 29.1401 - Anticollision light system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... minute. (d) Color. Each anticollision light must be aviation red and must meet the applicable... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Anticollision light system. 29.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1401 Anticollision light system. (a...
14 CFR 29.1401 - Anticollision light system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... minute. (d) Color. Each anticollision light must be aviation red and must meet the applicable... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Anticollision light system. 29.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Lights § 29.1401 Anticollision light system. (a...
Energy-efficient lighting system for television
Cawthorne, Duane C.
1987-07-21
A light control system for a television camera comprises an artificial light control system which is cooperative with an iris control system. This artificial light control system adjusts the power to lamps illuminating the camera viewing area to provide only sufficient artificial illumination necessary to provide a sufficient video signal when the camera iris is substantially open.
14 CFR 25.1401 - Anticollision light system.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., but not 180 cycles per minute. (d) Color. Each anticollision light must be either aviation red or... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Anticollision light system. 25.1401 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1401 Anticollision light system. (a...
Pastorino, Roberta; Milovanovic, Sonja; Stojanovic, Jovana; Efremov, Ljupcho; Amore, Rosarita; Boccia, Stefania
2016-01-01
Along with the proliferation of Open Access (OA) publishing, the interest for comparing the scientific quality of studies published in OA journals versus subscription journals has also increased. With our study we aimed to compare the methodological quality and the quality of reporting of primary epidemiological studies and systematic reviews and meta-analyses published in OA and non-OA journals. In order to identify the studies to appraise, we listed all OA and non-OA journals which published in 2013 at least one primary epidemiologic study (case-control or cohort study design), and at least one systematic review or meta-analysis in the field of oncology. For the appraisal, we picked up the first studies published in 2013 with case-control or cohort study design from OA journals (Group A; n = 12), and in the same time period from non-OA journals (Group B; n = 26); the first systematic reviews and meta-analyses published in 2013 from OA journals (Group C; n = 15), and in the same time period from non-OA journals (Group D; n = 32). We evaluated the methodological quality of studies by assessing the compliance of case-control and cohort studies to Newcastle and Ottawa Scale (NOS) scale, and the compliance of systematic reviews and meta-analyses to Assessment of Multiple Systematic Reviews (AMSTAR) scale. The quality of reporting was assessed considering the adherence of case-control and cohort studies to STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist, and the adherence of systematic reviews and meta-analyses to Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) checklist. Among case-control and cohort studies published in OA and non-OA journals, we did not observe significant differences in the median value of NOS score (Group A: 7 (IQR 7-8) versus Group B: 8 (7-9); p = 0.5) and in the adherence to STROBE checklist (Group A, 75% versus Group B, 80%; p = 0.1). The results did not change after adjustment for impact factor. The compliance with AMSTAR and adherence to PRISMA checklist were comparable between systematic reviews and meta-analyses published in OA and non-OA journals (Group C, 46.0% versus Group D, 55.0%; p = 0.06), (Group C, 72.0% versus Group D, 76.0%; p = 0.1), respectively). The epidemiological studies published in OA journals in the field of oncology approach the same methodological quality and quality of reporting as studies published in non-OA journals.
Pastorino, Roberta; Milovanovic, Sonja; Stojanovic, Jovana; Efremov, Ljupcho; Amore, Rosarita; Boccia, Stefania
2016-01-01
Introduction Along with the proliferation of Open Access (OA) publishing, the interest for comparing the scientific quality of studies published in OA journals versus subscription journals has also increased. With our study we aimed to compare the methodological quality and the quality of reporting of primary epidemiological studies and systematic reviews and meta-analyses published in OA and non-OA journals. Methods In order to identify the studies to appraise, we listed all OA and non-OA journals which published in 2013 at least one primary epidemiologic study (case-control or cohort study design), and at least one systematic review or meta-analysis in the field of oncology. For the appraisal, we picked up the first studies published in 2013 with case-control or cohort study design from OA journals (Group A; n = 12), and in the same time period from non-OA journals (Group B; n = 26); the first systematic reviews and meta-analyses published in 2013 from OA journals (Group C; n = 15), and in the same time period from non-OA journals (Group D; n = 32). We evaluated the methodological quality of studies by assessing the compliance of case-control and cohort studies to Newcastle and Ottawa Scale (NOS) scale, and the compliance of systematic reviews and meta-analyses to Assessment of Multiple Systematic Reviews (AMSTAR) scale. The quality of reporting was assessed considering the adherence of case-control and cohort studies to STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist, and the adherence of systematic reviews and meta-analyses to Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) checklist. Results Among case-control and cohort studies published in OA and non-OA journals, we did not observe significant differences in the median value of NOS score (Group A: 7 (IQR 7–8) versus Group B: 8 (7–9); p = 0.5) and in the adherence to STROBE checklist (Group A, 75% versus Group B, 80%; p = 0.1). The results did not change after adjustment for impact factor. The compliance with AMSTAR and adherence to PRISMA checklist were comparable between systematic reviews and meta-analyses published in OA and non-OA journals (Group C, 46.0% versus Group D, 55.0%; p = 0.06), (Group C, 72.0% versus Group D, 76.0%; p = 0.1), respectively). Conclusion The epidemiological studies published in OA journals in the field of oncology approach the same methodological quality and quality of reporting as studies published in non-OA journals. PMID:27167982
Natural light illumination system.
Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan
2010-12-10
In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary sources, depending on circumstances. The system is controlled by a light detector. We used optical simulation tools to design and simulate the efficiency of the active module. Finally, we used the natural light illumination system to provide natural illumination for a traffic tunnel. This system will provide a great number of benefits for the people who use it.
NASA Astrophysics Data System (ADS)
Galvis, D.; Exposito, C.; Osma, G.; Amado, L.; Ordóñez, G.
2016-07-01
This paper presents an analysis of hybrid lighting systems of Electrical Engineering Building in the Industrial University of Santander, which is a pilot of green building for warm- tropical conditions. Analysis of lighting performance of inner spaces is based on lighting curves obtained from characterization of daylighting systems of these spaces. A computation tool was made in Excel-Visual Basic to simulate the behaviour of artificial lighting system considering artificial control system, user behaviour and solar condition. Also, this tool allows to estimate the electrical energy consumption of the lighting system for a day, a month and a year.
Evaluating office lighting environments: Second-level analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, B.L.; Fisher, W.S.; Gillette, G.L.
1989-04-01
Data from a post-occupancy evaluation (POE) of 912 work stations with lighting power density (LPD), photometric, and occupant-response measures were examined in a detailed, second-level analysis. Seven types of lighting systems were identified with different combinations of direct and indirect ambient lighting, and task lighting and daylight. The mean illuminances at the primary task location were within the IES target values for office task with a range of mean illuminances from 32 to 75 fc, depending on the lighting system. The median LPD was about 2.36 watts/sq ft, with about one-third the work stations having LPD's at or below 2.0more » watts/sq ft. Although a majority of the occupants (69%) were satisfied about their lighting, the highest percentage of those expressing dissatisfaction (37%) with lighting had an indirect fluorescent furniture-mounted (IFFM) system. The negative reaction of so many people to the IFFM system suggests that the combination of task lighting with an indirect ambient system had an important influence on lighting satisfaction, even though task illuminances tended to be higher with the IFFM system. Concepts of lighting quality, visual health, and control were explored, as well as average luminance to explain the negative reactions to the combination of indirect lighting with furniture-mounted lighting.« less
Smooth light extraction in lighting optical fibre
NASA Astrophysics Data System (ADS)
Fernandez-Balbuena, A. A.; Vazquez-Molini, D.; Garcia-Botella, A.; Martinez-Anton, J. C.; Bernabeu, E.
2011-10-01
Recent advances in LED technology have relegated the use of optical fibre for general lighting, but there are several applications where it can be used as scanners lighting systems, daylight, cultural heritage lighting, sensors, explosion risky spaces, etc. Nowadays the use of high intensity LED to inject light in optical fibre increases the possibility of conjugate fibre + LED for lighting applications. New optical fibres of plastic materials, high core diameter up to 12.6 mm transmit light with little attenuation in the visible spectrum but there is no an efficient and controlled way to extract the light during the fibre path. Side extracting fibres extracts all the light on 2π angle so is not well suited for controlled lighting. In this paper we present an extraction system for mono-filament optical fibre which provides efficient and controlled light distribution. These lighting parameters can be controlled with an algorithm that set the position, depth and shape of the optical extraction system. The extraction system works by total internal reflection in the core of the fibre with high efficiency and low cost. A 10 m length prototype is made with 45° sectional cuts in the fibre core as extraction system. The system is tested with a 1W white LED illuminator in one side.
Solar concentrator with integrated tracking and light delivery system with summation
Maxey, Lonnie Curt
2015-05-05
A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector redirects the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and provides light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting that uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.
Solar concentrator with integrated tracking and light delivery system with collimation
Maxey, Lonnie Curt
2015-06-09
A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector directs the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and distributes light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting, uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-99 Section 86.1717-99 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-01 Section 86.1717-01 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-99 Section 86.1717-99 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Emission control diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. 86.1717-01 Section 86.1717-01 Protection of... diagnostic system for 1999 and later light-duty vehicles and light-duty trucks. (a) The provisions of § 86...
Connected Lighting Systems Efficiency Study$-$ PoE Cable Energy Losses, Part 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuenge, Jason; Kelly, Karsten; Poplawski, Michael
First report in a study of the efficiency of connected lighting systems. The report summarizes the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines recently introduced by the American National Standards Institute (ANSI) C137 Lighting Systems Committee.
78 FR 41810 - Proposed Revisions to Light Load Handling System and Operations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-11
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0148] Proposed Revisions to Light Load Handling System and... soliciting public comment on Section 9.1.4, ``Light Load Handling System and Operations'' of NUREG-0800... Federal Regulations (10 CFR) with respect to the light load handling system and related refueling...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riza, Nabeel Agha; Perez, Frank
A remote temperature sensing system includes a light source selectively producing light at two different wavelengths and a sensor device having an optical path length that varies as a function of temperature. The sensor receives light emitted by the light source and redirects the light along the optical path length. The system also includes a detector receiving redirected light from the sensor device and generating respective signals indicative of respective intensities of received redirected light corresponding to respective wavelengths of light emitted by the light source. The system also includes a processor processing the signals generated by the detector tomore » calculate a temperature of the device.« less
Optimization of light quality from color mixing light-emitting diode systems for general lighting
NASA Astrophysics Data System (ADS)
Thorseth, Anders
2012-03-01
Given the problem of metamerisms inherent in color mixing in light-emitting diode (LED) systems with more than three distinct colors, a method for optimizing the spectral output of multicolor LED system with regards to standardized light quality parameters has been developed. The composite spectral power distribution from the LEDs are simulated using spectral radiometric measurements of single commercially available LEDs for varying input power, to account for the efficiency droop and other non-linear effects in electrical power vs. light output. The method uses electrical input powers as input parameters in a randomized steepest decent optimization. The resulting spectral power distributions are evaluated with regard to the light quality using the standard characteristics: CIE color rendering index, correlated color temperature and chromaticity distance. The results indicate Pareto optimal boundaries for each system, mapping the capabilities of the simulated lighting systems with regard to the light quality characteristics.
NASA Technical Reports Server (NTRS)
Clark, T. A.; Salazar, G. A.; Brainard, G. C.; Litaker, H. L.; Hanifin, J.; Schwing, B. M.
2016-01-01
Even with no ambient lighting system "on", the International Space Station glows at night. The glow is caused by indicator lamps and displays that are not included with the specification of the ambient lighting system. How does this impact efforts to improve the astronaut's lighting environment to promote more effective sleep patterns? Do the extra indicators and displays add enough light to change the spectrum of light the crew sees during the day as well? If spacecraft environments are specifically engineered to have an ambient lighting system that emits a spectrum promoting a healthy circadian response, is there a way control the impact? The goal of this project is to investigate how additional light sources, such as displays and indicators change the effective light spectrum of the architectural lighting system and how impacts can be mitigated.
Cho, Il-Hyoung; Park, Jae-Hong; Kim, Young-Gyu
2005-01-01
A solar-driven, photocatalyzed degradation system using TiO2 slurry and immobilized systems was constructed and applied to the degradation of trichloroethylene (TCE) contaminated water using TiO2 with solar light. The experiments were carried out under constant weather conditions on a sunny day. Solar photocatalytic treatment efficiency of the solar light/TiO2 slurry system was compared with that of the solar light/TiO2 immobilized system. The operation of the solar light/TiO2 slurry and immobilized systems showed 100% (TiO2 slurry system), 80% (TiO2 immobilized system) degradation of the TCE after 6 h, with a chloride production yield of approximately 89% (TiO2 slurry system), 72% (TiO2 immobilized system). The oxidants such as H2O2 and S2O8(2-) in the TiO2 slurry and immobilized systems increased TCE degradation rate by suppressing the electron/hole recombination process. The degradation rate and relative toxicity reduction of TCE followed the order of solar light/TiO2 slurry + S2O8(2-) > solar light/TiO2 slurry + H2O2 > solar light/TiO2 immobilized + S2O8(2-) > solar light/TiO2 slurry > solar light/TiO2 immobilized + H2O2 > solar light/TiO2 immobilized. Finally, following to the toxicity result, the acute toxicity was reduced by below toxicity endpoint (EC50 concentration) following the treatment. It means that many of the metabolites of TCE reduction are less toxic to Vibrio fischeri than the parent compound. Based on these results, TCE can be efficiently and safely treated in a solar-driven, photocatalyzed degradation system.
A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST.
Xiao, Shumei; Zang, Qing; Han, Xiaofeng; Wang, Tengfei; Yu, Jin; Zhao, Junyu
2016-07-01
Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.
Development of a PET/Cerenkov-light hybrid imaging system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Hamamura, Fuka; Kato, Katsuhiko
2014-09-15
Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light.more » The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging system is useful to evaluate the merits and the limitations of Cerenkov-light imaging in molecular imaging research.« less
Particle measurement systems and methods
Steele, Paul T [Livermore, CA
2011-10-04
A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.
Code of Federal Regulations, 2010 CFR
2010-10-01
... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...
Code of Federal Regulations, 2012 CFR
2012-10-01
... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...
Code of Federal Regulations, 2013 CFR
2013-10-01
... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...
Code of Federal Regulations, 2014 CFR
2014-10-01
... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...
Code of Federal Regulations, 2011 CFR
2011-10-01
... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...
Thermoresponsive scattering coating for smart white LEDs.
Bauer, Jurica; Verbunt, Paul P C; Lin, Wan-Yu; Han, Yang; Van, My-Phung; Cornelissen, Hugo J; Yu, Joan J H; Bastiaansen, Cees W M; Broer, Dirk J
2014-12-15
White light emitting diode (LED) systems, capable of lowering the color temperature of emitted light on dimming, have been reported in the literature. These systems all use multiple color LEDs and complex control circuitry. Here we present a novel responsive lighting system based on a single white light emitting LED and a thermoresponsive scattering coating. The coated LED automatically emits light of lower correlated color temperature (CCT) when the power is reduced. We also present results on the use of multiple phosphors in the white light LED allowing for the emission of warm white light in the range between 2900 K and 4150 K, and with a chromaticity complying with the ANSI standards (C78.377). This responsive warm white light LED-system with close-to-ideal emission characteristics is highly interesting for the lighting industry.
46 CFR 112.01-5 - Manual emergency lighting and power system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...
46 CFR 112.01-5 - Manual emergency lighting and power system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...
46 CFR 112.01-5 - Manual emergency lighting and power system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...
46 CFR 112.01-5 - Manual emergency lighting and power system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
46 CFR 112.01-5 - Manual emergency lighting and power system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Manual emergency lighting and power system. 112.01-5 Section 112.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-5 Manual...
46 CFR 112.01-10 - Automatic emergency lighting and power system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Automatic emergency lighting and power system. 112.01-10 Section 112.01-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-10...
Salzman, Gary C.; Mullaney, Paul F.
1976-01-01
The disclosure relates to a system incorporating an ellipsoidal flow chamber having light reflective walls for low level light detection in practicing cellular analysis. The system increases signal-to-noise ratio by a factor of ten over prior art systems. In operation, laser light passes through the primary focus of the ellipsoid. A controlled flow of cells simultaneously passes through this focus so that the laser light impinges on the cells and is modulated by the cells. The reflective walls of the ellipsoid reflect the cell-modulated light to the secondary focus of the ellipsoid. A tapered light guide at the secondary focus picks up a substantial portion of modulated reflective light and directs it onto a light detector to produce a signal. The signal is processed to obtain the intensity distribution of the modulated light and hence sought after characteristics of the cells. In addition, cells may be dyed so as to fluoresce in response to the laser light and their fluorescence may be processed as cell-modulated light above described. A light discriminating filter would be used to distinguish reflected modulated laser light from reflected fluorescent light.
Remote monitoring of LED lighting system performance
NASA Astrophysics Data System (ADS)
Thotagamuwa, Dinusha R.; Perera, Indika U.; Narendran, Nadarajah
2016-09-01
The concept of connected lighting systems using LED lighting for the creation of intelligent buildings is becoming attractive to building owners and managers. In this application, the two most important parameters include power demand and the remaining useful life of the LED fixtures. The first enables energy-efficient buildings and the second helps building managers schedule maintenance services. The failure of an LED lighting system can be parametric (such as lumen depreciation) or catastrophic (such as complete cessation of light). Catastrophic failures in LED lighting systems can create serious consequences in safety critical and emergency applications. Therefore, both failure mechanisms must be considered and the shorter of the two must be used as the failure time. Furthermore, because of significant variation between the useful lives of similar products, it is difficult to accurately predict the life of LED systems. Real-time data gathering and analysis of key operating parameters of LED systems can enable the accurate estimation of the useful life of a lighting system. This paper demonstrates the use of a data-driven method (Euclidean distance) to monitor the performance of an LED lighting system and predict its time to failure.
Analysis of energy efficient highway lighting retrofits.
DOT National Transportation Integrated Search
2015-06-01
Solid state lighting technology is advancing rapidly to a point where light emitting diode (LED) lighting : systems can be viable replacements for existing lighting systems using high pressure sodium (HPS). The : present report summarizes analyses co...
High temperature, minimally invasive optical sensing modules
Riza, Nabeel Agha [Oviedo, FL; Perez, Frank [Tujunga, CA
2008-02-05
A remote temperature sensing system includes a light source selectively producing light at two different wavelengths and a sensor device having an optical path length that varies as a function of temperature. The sensor receives light emitted by the light source and redirects the light along the optical path length. The system also includes a detector receiving redirected light from the sensor device and generating respective signals indicative of respective intensities of received redirected light corresponding to respective wavelengths of light emitted by the light source. The system also includes a processor processing the signals generated by the detector to calculate a temperature of the device.
46 CFR 112.43-9 - Signaling lights.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Signaling lights. 112.43-9 Section 112.43-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-9 Signaling lights. Each signaling light must be...
46 CFR 112.43-9 - Signaling lights.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Signaling lights. 112.43-9 Section 112.43-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-9 Signaling lights. Each signaling light must be...
46 CFR 112.43-9 - Signaling lights.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Signaling lights. 112.43-9 Section 112.43-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-9 Signaling lights. Each signaling light must be...
46 CFR 112.43-9 - Signaling lights.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Signaling lights. 112.43-9 Section 112.43-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-9 Signaling lights. Each signaling light must be...
46 CFR 112.43-9 - Signaling lights.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Signaling lights. 112.43-9 Section 112.43-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-9 Signaling lights. Each signaling light must be...
Electronic Dimmable Ballasts for High-Intensity Discharge Sodium Vapor and Metal Halide Lamps
NASA Technical Reports Server (NTRS)
Boulanger, Richard
2002-01-01
Two types of high-intensity discharge lamps were tested using dimmable ballasts. The main purpose for evaluating this lighting system was to determine its efficacy for saving power. Whereas previous variable level lighting systems for HID lamps in Advanced Life Support applications were adjustable in two or three steps using capacitive switching, this system allows for continuously adjustable lamp output. This type of lighting system when used as part of an Advanced Life Support biomass production system would provide only the amount of light energy a crop needed at any particular point in its growth cycle. Since most of the equivalent system mass in an ALS system is from the light energy required to grow the crops, controlling that light energy dynamically over a continuous range of operation would dramatically reduce the power consumption and reduce system mass.
Evolving Our Evaluation of Luminous Environments
NASA Technical Reports Server (NTRS)
Clark, Toni
2016-01-01
The advance in solid state light emitting technologies and optics for lighting and visual communication necessitates the evaluation of how NASA envisions spacecraft lighting architectures and how NASA uses industry standards for the design and evaluation of lighting systems. Current NASA lighting standards and requirements for existing architectures focus on the separate ability of a lighting system to throw light against a surface or the ability of a display system to provide the appropriate visual contrast. This project investigated large luminous surface lamps as an alternative or supplement to overhead lighting. The efficiency of the technology was evaluated for uniformity and power consumption.
Design and construction evaluation of a photovoltaic DC LED lighting system
NASA Astrophysics Data System (ADS)
Bhamidipati, Jyotsna
2008-08-01
The market demand for commercialization of Photovoltaic (PV) systems depends a lot on the reliability, efficiency and performance of various components within the system. PV panels produce DC power when exposed to sunlight, and an inverter converts this to AC power in a typical solar powered building. Though, PV lighting has existed for a long time it hasn't been very effective, as incandescent light sources were commonly used which are inefficient. Today fluorescent fixtures are mostly used with PV's due to its high efficacy. Light-emitting diodes present a new vision to energy efficiency in lighting design with their low energy consumption. Current research predicts improved efficiencies of LED light fixtures and their commercial use is a few years away. LEDs which operate on DC voltages when coupled with photovoltaics can be a simple PV lighting application and a sustainable solution with potential for payback. This research evaluates the design and construction of a photovoltaic DC LED lighting system for a solar house at Pennsylvania State University. A detailed cost and payback analysis of a PV DC LED lighting system is presented in this research. PV output simulations for the solar house are presented. Results presented in this research indicate that the Solid state lighting market is evolving rapidly and that LED's are a choice in stand-alone photovoltaic DC lighting systems. The efficiency and the cost-effectiveness of such systems would however improve in the coming years with research and development now focused on PV systems and on Solid state lighting technologies.
Homeostasis lighting control based on relationship between lighting environment and human behavior
NASA Astrophysics Data System (ADS)
Ueda, Risa; Mita, Akira
2015-03-01
Although each person has own preferences, living spaces which can respond to various preferences and needs have not become reality. Focusing on the lighting environments which influence on the impression of living spaces, this research aims to offer comfortable lighting environments for each resident by a flexible control. This research examines the relationship between lighting environments and human behaviors considering colored lights. In accord with the relationship, this research proposes an illuminance-color control system which flexibly changes spatial environments responding to human conditions. Firstly, the psychological evaluation was conducted in order to build human models for various environments. As a result, preferred lighting environments for each examinee were determined for particular behaviors. Moreover, satisfaction levels of lighting environments were calculated by using seven types of impression of the environments as parameters. The results were summarized as human models. Secondly, this research proposed "Homeostasis Lighting Control System", which employs the human models. Homeostasis lighting control system embodies the algorithm of homeostasis, which is one of the functions of the physiological adaptation. Human discomfort feelings are obtained automatically by the sensor agent robot. The system can offer comfortable lighting environments without controlling environments by residents autonomously based on the information from the robot. This research takes into accounts both illuminance and color. The robot communicates with the server which contains human models, then the system corresponds to individuals. Combining these three systems, the proposed system can effectively control the lighting environment. At last, the feasibility of the proposed system was verified by simulation experiments.
Intelligent Luminance Control of Lighting Systems Based on Imaging Sensor Feedback
Liu, Haoting; Zhou, Qianxiang; Yang, Jin; Jiang, Ting; Liu, Zhizhen; Li, Jie
2017-01-01
An imaging sensor-based intelligent Light Emitting Diode (LED) lighting system for desk use is proposed. In contrast to the traditional intelligent lighting system, such as the photosensitive resistance sensor-based or the infrared sensor-based system, the imaging sensor can realize a finer perception of the environmental light; thus it can guide a more precise lighting control. Before this system works, first lots of typical imaging lighting data of the desk application are accumulated. Second, a series of subjective and objective Lighting Effect Evaluation Metrics (LEEMs) are defined and assessed for these datasets above. Then the cluster benchmarks of these objective LEEMs can be obtained. Third, both a single LEEM-based control and a multiple LEEMs-based control are developed to realize a kind of optimal luminance tuning. When this system works, first it captures the lighting image using a wearable camera. Then it computes the objective LEEMs of the captured image and compares them with the cluster benchmarks of the objective LEEMs. Finally, the single LEEM-based or the multiple LEEMs-based control can be implemented to get a kind of optimal lighting effect. Many experiment results have shown the proposed system can tune the LED lamp automatically according to environment luminance changes. PMID:28208781
Intelligent Luminance Control of Lighting Systems Based on Imaging Sensor Feedback.
Liu, Haoting; Zhou, Qianxiang; Yang, Jin; Jiang, Ting; Liu, Zhizhen; Li, Jie
2017-02-09
An imaging sensor-based intelligent Light Emitting Diode (LED) lighting system for desk use is proposed. In contrast to the traditional intelligent lighting system, such as the photosensitive resistance sensor-based or the infrared sensor-based system, the imaging sensor can realize a finer perception of the environmental light; thus it can guide a more precise lighting control. Before this system works, first lots of typical imaging lighting data of the desk application are accumulated. Second, a series of subjective and objective Lighting Effect Evaluation Metrics (LEEMs) are defined and assessed for these datasets above. Then the cluster benchmarks of these objective LEEMs can be obtained. Third, both a single LEEM-based control and a multiple LEEMs-based control are developed to realize a kind of optimal luminance tuning. When this system works, first it captures the lighting image using a wearable camera. Then it computes the objective LEEMs of the captured image and compares them with the cluster benchmarks of the objective LEEMs. Finally, the single LEEM-based or the multiple LEEMs-based control can be implemented to get a kind of optimal lighting effect. Many experiment results have shown the proposed system can tune the LED lamp automatically according to environment luminance changes.
46 CFR 25.45-1 - Heating and lighting systems on vessels carrying passengers for hire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Heating and lighting systems on vessels carrying passengers for hire. 25.45-1 Section 25.45-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS Cooking, Heating, and Lighting Systems § 25.45-1 Heating and lighting systems...
System and Method for Determining Fluence of a Substance
NASA Technical Reports Server (NTRS)
Banks, Bruce A. (Inventor)
2016-01-01
A system and method for measuring a fluence of gas are disclosed. The system has a first light detector capable of outputting an electrical signal based on an amount of light received. A barrier is positionable adjacent the first light detector and is susceptible to a change in dimension from the fluence of the gas. The barrier permits a portion of light from being received by the first light detector. The change in the dimension of the barrier changes the electrical signal output from the first light detector. A second light detector is positionable to receive light representative of the first light detector without the barrier. The system and method have broad application to detect fluence of gas that may cause erosion chemical reaction causing erosive deterioration. One application is in low orbit Earth for detecting the fluence of atomic oxygen.
The system analysis of light field information collection based on the light field imaging
NASA Astrophysics Data System (ADS)
Wang, Ye; Li, Wenhua; Hao, Chenyang
2016-10-01
Augmented reality(AR) technology is becoming the study focus, and the AR effect of the light field imaging makes the research of light field camera attractive. The micro array structure was adopted in most light field information acquisition system(LFIAS) since emergence of light field camera, micro lens array(MLA) and micro pinhole array(MPA) system mainly included. It is reviewed in this paper the structure of the LFIAS that the Light field camera commonly used in recent years. LFIAS has been analyzed based on the theory of geometrical optics. Meanwhile, this paper presents a novel LFIAS, plane grating system, we call it "micro aperture array(MAA." And the LFIAS are analyzed based on the knowledge of information optics; This paper proves that there is a little difference in the multiple image produced by the plane grating system. And the plane grating system can collect and record the amplitude and phase information of the field light.
NASA Technical Reports Server (NTRS)
Haines, R. F.
1973-01-01
Thirty six students and 54 commercial airline pilots were tested in the fog chamber to determine the effect of runway edge and centerline light intensity and spacing, fog density, ambient luminance level, and lateral and vertical offset distance of the subject from the runway's centerline upon horizontal visual range. These data were obtained to evaluate the adequacy of a balanced lighting system to provide maximum visual range in fog viewing both centerline and runway edge lights. The daytime system was compared against two other candidate lighting systems; the nighttime system was compared against other candidate lighting systems. The second objective was to determine if visual range is affected by lights between the subject and the farthestmost light visible through the fog. The third objective was to determine if college student subjects differ from commercial airline pilots in their horizontal visual range through fog. Two studies were conducted.
NASA Technical Reports Server (NTRS)
Vukobratovich, Daniel; Richard, Ralph M.; Valente, Tina M.; Cho, Myung K.
1990-01-01
Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature was made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best curve for each case. A best fitting curve program tests nineteen different equations and ranks a goodness-to-fit for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.
Design of the optical structure of airfield in-pavement LED runway edge lights
NASA Astrophysics Data System (ADS)
Ma, Xiaodan; Yang, Jianhong; Peng, Jun; Li, Lei
2017-02-01
Airfield lighting system is an important aiding system of civil aviation airport that guarantees the taking off, landing, taxiing of airplanes at night, with low visibility, or under other complicated weather conditions. In-pavement LED runway edge lights, with the highest degree of light intensity, are the most important lights for safe civil aviation and are most difficult to design within airfield lighting system. With LED as the source of light and the secondary optical design as the core, in light of basic laws of Fresnel loss and total reflection and the principles of edge-ray etendue conservation and the conservation of energy to design major optical elements as lens, prism of the lamp, the in-pavement LED runway edge lights design successfully solves the designing problem of high-power, high-intensity LED airfield lights with narrow beam angle at closed environment. This success is of great significance for the improvement of LED airfield lighting system in China.
Lighting Automation Flying an Earthlike Habitat
NASA Technical Reports Server (NTRS)
Clark, Toni A.; Kolomenski, Andrei
2017-01-01
Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.
Lighting Automation - Flying an Earthlike Habitat
NASA Technical Reports Server (NTRS)
Clark, Tori A. (Principal Investigator); Kolomenski, Andrei
2017-01-01
Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.
New Trends in Educational Lighting Systems.
ERIC Educational Resources Information Center
Murphy, Peter
2001-01-01
Explores technological trends for improving campus lighting, including the use of direct-indirect suspended fluorescent lighting, suspended linear lighting, high-efficiency optical systems, and occupancy and daylight sensors. (GR)
2010-11-01
Connecting the Medtronic MAST Quadrant Illumination System, Radiance Illumination System, or Radiance X Illumination System--all of which are specialized fiberoptic light cables used with the company's minimally invasive spinal products--to a high-power surgical light source significantly increases the risk of patient burns. Hospitals should ensure that the products are used only with 100 W light sources and 5 mm light cables, as prescribed in the product labeling.
A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Shumei; Zang, Qing, E-mail: zangq@ipp.ac.cn; Han, Xiaofeng
Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump systemmore » can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.« less
Design Considerations for a Water Treatment System Utilizing Ultra-Violet Light Emitting Diodes
2014-03-27
DESIGN CONSIDERATIONS FOR A WATER TREATMENT SYSTEM UTILIZING ULTRA-VIOLET LIGHT EMITTING DIODES...the United States. ii AFIT-ENV-14-M-58 DESIGN CONSIDERATIONS FOR A WATER TREATMENT SYSTEM UTILIZING ULTRA-VIOLET LIGHT EMITTING DIODES...DISTRIBUTION UNLIMITED. iii AFIT-ENV-14-M-58 DESIGN CONSIDERATIONS FOR A WATER TREATMENT SYSTEM UTILIZING ULTRA-VIOLET LIGHT EMITTING
Field Commissioning of a Daylight-Dimming Lighting System.
ERIC Educational Resources Information Center
Floyd, David B.; Parker, Danny S.
A Florida elementary school cafeteria, retrofitted with a fluorescent lighting system that dims in response to available daylight, was evaluated through real time measurement of lighting and air conditioning power, work plane illumination, and interior/exterior site conditions. The new system produced a 27 percent reduction in lighting power due…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, M; Penjweini, R; Zhu, T
Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Softwaremore » upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.« less
Optical multi-species gas monitoring sensor and system
NASA Technical Reports Server (NTRS)
Korman, Valentin (Inventor); Polzin, Kurt A. (Inventor)
2012-01-01
The system includes at least one light source generating light energy having a corresponding wavelength. The system's sensor is based on an optical interferometer that receives light energy from each light source. The interferometer includes a free-space optical path disposed in an environment of interest. The system's sensor includes an optical device disposed in the optical path that causes light energy of a first selected wavelength to continue traversing the optical path whereas light energy of at least one second selected wavelength is directed away from the optical path. The interferometer generates an interference between the light energy of the first selected wavelength so-traversing the optical path with the light energy at the corresponding wavelength incident on the optical interferometer. A first optical detector detects the interference. At least one second detector detects the light energy at the at least one second selected wavelength directed away from the optical path.
Wireless sensor and actuator networks for lighting energy efficiency and user satisfaction
NASA Astrophysics Data System (ADS)
Wen, Yao-Jung
Buildings consume more than one third of the primary energy generated in the U.S., and lighting alone accounts for approximately 30% of the energy usage in commercial buildings. As the largest electricity consumer of all building electrical systems, lighting harbors the greatest potential for energy savings in the commercial sector. Fifty percent of current energy consumption could be reduced with energy-efficient lighting management strategies. While commercial products do exist, they are poorly received due to exorbitant retrofitting cost and unsatisfactory performance. As a result, most commercial buildings, especially legacy buildings, have not taken advantage of the opportunity to generate savings from lighting. The emergence of wireless sensor and actuator network (WSAN) technologies presents an alternative that circumvents costly rewiring and promises better performance than existing commercial lighting systems. The goal of this dissertation research is to develop a framework for wireless-networked lighting systems with increased cost effectiveness, energy efficiency, and user satisfaction. This research is realized through both theoretical developments and implementations. The theoretical research aims at developing techniques for harnessing WSAN technologies to lighting hardware and control strategies. Leveraging redundancy, a sensor validation and fusion algorithm is developed for extracting pertinent lighting information from the disturbance-prone desktop-mounted photosensors. An adaptive sensing strategy optimizes the timing of data acquisition and power-hungry wireless transmission of sensory feedback in real-time lighting control. Exploiting the individual addressability of wireless-enabled luminaires, a lighting optimization algorithm is developed to create the optimal lighting that minimizes energy usage while satisfying occupants' diverse lighting preferences. The wireless-networked lighting system was implemented and tested in a number of real-life settings. A human subject study conducted in a private office concluded that the research system was competitive with the commercial lighting system with much fewer retrofitting requirements. The system implemented in a shared-space office realized a self-configuring mesh network with wireless photosensors and light actuators, and demonstrated a 50% energy savings and increased performance when harvesting daylight through windows is possible. The cost analysis revealed a reasonable payback period after the system is optimized for commercialization and confirms the marketing feasibility.
Optimized achromatic phase-matching system and method
Trebino, R.; DeLong, K.; Hayden, C.
1997-07-15
An optical system for efficiently directing a large bandwidth light (e.g., a femtosecond laser pulse) onto a nonlinear optical medium includes a plurality of optical elements for directing an input light pulse onto a nonlinear optical medium arranged such that the angle {theta}{sub in} which the light pulse directed onto the nonlinear optical medium is substantially independent of a position x of the light beam entering the optical system. The optical system is also constructed such that the group velocity dispersion of light pulses passing through the system can be tuned to a desired value including negative group velocity dispersion. 15 figs.
Optimized achromatic phase-matching system and method
Trebino, Rick; DeLong, Ken; Hayden, Carl
1997-01-01
An optical system for efficiently directing a large bandwidth light (e.g., a femtosecond laser pulse) onto a nonlinear optical medium includes a plurality of optical elements for directing an input light pulse onto a nonlinear optical medium arranged such that the angle .theta..sub.in which the light pulse directed onto the nonlinear optical medium is substantially independent of a position x of the light beam entering the optical system. The optical system is also constructed such that the group velocity dispersion of light pulses passing through the system can be tuned to a desired value including negative group velocity dispersion.
One dimensional wavefront distortion sensor comprising a lens array system
Neal, Daniel R.; Michie, Robert B.
1996-01-01
A 1-dimensional sensor for measuring wavefront distortion of a light beam as a function of time and spatial position includes a lens system which incorporates a linear array of lenses, and a detector system which incorporates a linear array of light detectors positioned from the lens system so that light passing through any of the lenses is focused on at least one of the light detectors. The 1-dimensional sensor determines the slope of the wavefront by location of the detectors illuminated by the light. The 1 dimensional sensor has much greater bandwidth that 2 dimensional systems.
One dimensional wavefront distortion sensor comprising a lens array system
Neal, D.R.; Michie, R.B.
1996-02-20
A 1-dimensional sensor for measuring wavefront distortion of a light beam as a function of time and spatial position includes a lens system which incorporates a linear array of lenses, and a detector system which incorporates a linear array of light detectors positioned from the lens system so that light passing through any of the lenses is focused on at least one of the light detectors. The 1-dimensional sensor determines the slope of the wavefront by location of the detectors illuminated by the light. The 1 dimensional sensor has much greater bandwidth that 2 dimensional systems. 8 figs.
2012-01-01
Background Plant growth and development depend on the availability of light. Lighting systems therefore play crucial roles in plant studies. Recent advancements of light-emitting diode (LED) technologies provide abundant opportunities to study various plant light responses. The LED merits include solidity, longevity, small element volume, radiant flux controllability, and monochromaticity. To apply these merits in plant light response studies, a lighting system must provide precisely controlled light spectra that are useful for inducing various plant responses. Results We have developed a plant lighting system that irradiated a 0.18 m2 area with a highly uniform distribution of photon flux density (PFD). The average photosynthetic PFD (PPFD) in the irradiated area was 438 micro-mol m–2 s–1 (coefficient of variation 9.6%), which is appropriate for growing leafy vegetables. The irradiated light includes violet, blue, orange-red, red, and far-red wavelength bands created by LEDs of five types. The PFD and mixing ratio of the five wavelength-band lights are controllable using a computer and drive circuits. The phototropic response of oat coleoptiles was investigated to evaluate plant sensitivity to the light control quality of the lighting system. Oat coleoptiles irradiated for 23 h with a uniformly distributed spectral PFD (SPFD) of 1 micro-mol m–2 s–1 nm–1 at every peak wavelength (405, 460, 630, 660, and 735 nm) grew almost straight upwards. When they were irradiated with an SPFD gradient of blue light (460 nm peak wavelength), the coleoptiles showed a phototropic curvature in the direction of the greater SPFD of blue light. The greater SPFD gradient induced the greater curvature of coleoptiles. The relation between the phototropic curvature (deg) and the blue-light SPFD gradient (micro-mol m–2 s–1 nm–1 m–1) was 2 deg per 1 micro-mol m–2 s–1 nm–1 m–1. Conclusions The plant lighting system, with a computer with a graphical user interface program, can control the PFD and mixing ratios of five wavelength-band lights. A highly uniform PFD distribution was achieved, although an intentionally distorted PFD gradient was also created. Phototropic responses of oat coleoptiles to the blue light gradient demonstrated the merit of fine controllability of this plant lighting system. PMID:23173915
Cyber Security for Lighting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Fact sheet discusses cyber threats unique to lighting control systems in buildings and helps facility managers identify the types of lighting control systems that could introduce cybersecurity risks. Download the fact sheet.
Affordable and personalized lighting using inverse modeling and virtual sensors
NASA Astrophysics Data System (ADS)
Basu, Chandrayee; Chen, Benjamin; Richards, Jacob; Dhinakaran, Aparna; Agogino, Alice; Martin, Rodney
2014-03-01
Wireless sensor networks (WSN) have great potential to enable personalized intelligent lighting systems while reducing building energy use by 50%-70%. As a result WSN systems are being increasingly integrated in state-ofart intelligent lighting systems. In the future these systems will enable participation of lighting loads as ancillary services. However, such systems can be expensive to install and lack the plug-and-play quality necessary for user-friendly commissioning. In this paper we present an integrated system of wireless sensor platforms and modeling software to enable affordable and user-friendly intelligent lighting. It requires ⇠ 60% fewer sensor deployments compared to current commercial systems. Reduction in sensor deployments has been achieved by optimally replacing the actual photo-sensors with real-time discrete predictive inverse models. Spatially sparse and clustered sub-hourly photo-sensor data captured by the WSN platforms are used to develop and validate a piece-wise linear regression of indoor light distribution. This deterministic data-driven model accounts for sky conditions and solar position. The optimal placement of photo-sensors is performed iteratively to achieve the best predictability of the light field desired for indoor lighting control. Using two weeks of daylight and artificial light training data acquired at the Sustainability Base at NASA Ames, the model was able to predict the light level at seven monitored workstations with 80%-95% accuracy. We estimate that 10% adoption of this intelligent wireless sensor system in commercial buildings could save 0.2-0.25 quads BTU of energy nationwide.
NASA Astrophysics Data System (ADS)
Obara, Shin'ya
Plant shoot configurations evolve so that maximum sunlight may be obtained. The objective of this study is to develop a compact light-condensing system mimicking a plant shoot configuration that is applicable to a light source from a large area. In this paper, the relationship between the position of a light source (the sun) and the rate at which light is absorbed by each leaf was investigated in detail for plant shoot models of a dogwood (simple leaf) and a ginkgo tree (lobed leaf). The rate of light quantum received in each leaf model is reported to an analysis program that uses cross entropy (CE). The analyses showed that the peak amount of light received in the plant-shoot-light-condensing system was during February (vernal equinox) and October (autumnal equinox). Similarly, the rate of light quantum received in each leaf was measured with the CE. The results found that the plant-shoot-light-condensing system that maximizes the amount of light received has differences in the light received in each leaf. Furthermore, the light-condensing characteristics of the ginkgo biloba model are better than the dogwood model. The light-condensing characteristics of a leaf are influenced by the size, a lobe, shape, and the length of the branch.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Lynn; Arquit Niederberger, Anne
Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensuremore » SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...
Code of Federal Regulations, 2012 CFR
2012-10-01
... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...
Code of Federal Regulations, 2011 CFR
2011-10-01
... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...
Code of Federal Regulations, 2013 CFR
2013-10-01
... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...
Side-emitting illuminators using LED sources
NASA Astrophysics Data System (ADS)
Zhao, Feng; Van Derlofske, John F.
2003-11-01
This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.
14 CFR 29.1385 - Position light system installation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... position lights and the rear position light must make a single circuit. (e) Light covers and color filters. Each light cover or color filter must be at least flame resistant and may not change color or shape or... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light system installation. 29.1385...
14 CFR 27.1385 - Position light system installation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... position lights and the rear position light must make a single circuit. (e) Light covers and color filters. Each light cover or color filter must be at least flame resistant and may not change color or shape or... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light system installation. 27.1385...
Portable lamp with dynamically controlled lighting distribution
Siminovitch, Michael J.; Page, Erik R.
2001-01-01
A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.
Multi-channel medical imaging system
Frangioni, John V
2013-12-31
A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.
Multi-channel medical imaging system
Frangioni, John V.
2016-05-03
A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0237] Cost-Benefit Analysis for Radwaste Systems for Light... (RG) 1.110, ``Cost-Benefit Analysis for Radwaste Systems for Light-Water-Cooled Nuclear Power Reactors... components for light water nuclear power reactors. ADDRESSES: Please refer to Docket ID NRC-2013-0237 when...
Headlamps for light based driver assistance
NASA Astrophysics Data System (ADS)
Götz, M.; Kleinkes, M.
2008-04-01
Driving at night is dangerous. Although only 25% of all driving tasks are performed at night, nearly half of all fatal accidents happen in this time. In order to increase safety when driving under poor visibility conditions, automotive front lighting systems have undergone a strong development in the last fifteen years. One important milestone was the introduction of Xenon headlamps in 1992, which provide more and brighter light for road illumination than ever before. Since then the paradigm of simply providing more light has changed toward providing optimised light distributions, which support the driver's perception. A first step in this direction was the introduction of dynamic bend lighting and cornering light in 2003. In 2006 the first full AFS headlamp (Adaptive Front Lighting System) allowed an optimised adoption of the light distribution to the driving situation. These systems use information provided by vehicle sensors and an intelligent algorithm to guide light towards those areas where needed. Nowadays, even more information about the vehicle's environment is available. Image processing systems, for example, allow to detect other traffic participants, their speed and their driving directions. In future headlamp systems these data will be used to constantly regulate the reach of the light distribution thus allowing a maximal reach without providing glare. Moreover, technologies that allow to constantly use a high-beam light distribution are under development. These systems will illuminate the whole traffic area only excluding other traffic participants. LED light sources will play a significant role in these scenarios, since they allow to precisely illuminate certain areas of the road, while neighbouring parts will be left in dark.
Spectrally-balanced chromatic approach-lighting system
NASA Technical Reports Server (NTRS)
Chase, W. D.
1977-01-01
Approach lighting system employing combinations of red and blue lights reduces problem of color-based optical illusions. System exploits inherent chromatic aberration of eye to create three-dimensional effect, giving pilot visual clues of position.
A Red-Light Running Prevention System Based on Artificial Neural Network and Vehicle Trajectory Data
Li, Pengfei; Li, Yan; Guo, Xiucheng
2014-01-01
The high frequency of red-light running and complex driving behaviors at the yellow onset at intersections cannot be explained solely by the dilemma zone and vehicle kinematics. In this paper, the author presented a red-light running prevention system which was based on artificial neural networks (ANNs) to approximate the complex driver behaviors during yellow and all-red clearance and serve as the basis of an innovative red-light running prevention system. The artificial neural network and vehicle trajectory are applied to identify the potential red-light runners. The ANN training time was also acceptable and its predicting accurate rate was over 80%. Lastly, a prototype red-light running prevention system with the trained ANN model was described. This new system can be directly retrofitted into the existing traffic signal systems. PMID:25435870
Li, Pengfei; Li, Yan; Guo, Xiucheng
2014-01-01
The high frequency of red-light running and complex driving behaviors at the yellow onset at intersections cannot be explained solely by the dilemma zone and vehicle kinematics. In this paper, the author presented a red-light running prevention system which was based on artificial neural networks (ANNs) to approximate the complex driver behaviors during yellow and all-red clearance and serve as the basis of an innovative red-light running prevention system. The artificial neural network and vehicle trajectory are applied to identify the potential red-light runners. The ANN training time was also acceptable and its predicting accurate rate was over 80%. Lastly, a prototype red-light running prevention system with the trained ANN model was described. This new system can be directly retrofitted into the existing traffic signal systems.
Photoreceptor System for Melatonin Regulation and Phototherapy
NASA Technical Reports Server (NTRS)
Glickman, Gena (Inventor); Brainard, George (Inventor)
2010-01-01
The present invention involves a light system for stimulating or regulating neuroendocrine, circadian, and photoneural systems in mammals based upon the discovery of peak sensitivity ranging from 425-505 nm; a light meter system for quantifying light which stimulates or regulates mammalian circadian, photoneural, and neuroendocrine systems. The present invention also relates to translucent and transparent materials, and lamps or other light sources with or without filters capable of stimulating or regulating neuroendocrine, circadian, and photoneural systems in mammals. Additionally, the present invention involves treatment of mammals with a wide variety of disorders or deficits, including light responsive disorders, eating disorders, menstrual cycle disorders, non-specific alerting and performance deficits, hormone-sensitive cancers, and cardiovascular disorders.
Scaling laws for light-weight optics
NASA Technical Reports Server (NTRS)
Valente, Tina M.
1990-01-01
Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature has been made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best fit curve for each case. A best fitting curve program tests nineteen different equations and ranks a 'goodness of fit' for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.
A non-laser light source for photodynamic therapy: in vitro effects on normal and malignant cells.
Kashtan, Hanoch; Haddad, Riad; Greenberg, Ron; Skornick, Yehuda; Kaplan, Ofer
2002-01-01
Photodynamic therapy (PDT) involves the use of photosensitizing drugs combined with light to treat tumors. Laser systems, the current source of light for PDT, have several inherent drawbacks: the spectrum is essentially monochromatic which may be problematic for second generation photosensitizers, the systems are bulky and nearly impossible to move between hospital locations and require complicated electrical and cooling installations, the cost of a typical system is enormous, and its maintenance and operation require highly trained personnel. We now introduce a new non-laser light system, Versa-Light, which appears to work as effectively and has none of the above drawbacks. A series of in vitro studies were performed using various murine and human normal and cancer cells which underwent PDT using aluminum phthalocyanine (AlPcS4) as a photosensitizer and Versa-Light as the light source. PDT of cancer cells at light energy levels of 50, 100 and 200 j/cm2 significantly decreased cell viability. PDT also decreased cell viability of normal murine splenocytes and normal human lymphocytes, but to a lesser extent. The observed significant hyperthermia was light dose-dependent. We believe that Versa-Light can replace laser systems as an enhanced light source for PDT. Further in vitro and pre-clinical studies are in progress.
A sensor-less LED dimming system based on daylight harvesting with BIPV systems.
Yoo, Seunghwan; Kim, Jonghun; Jang, Cheol-Yong; Jeong, Hakgeun
2014-01-13
Artificial lighting in office buildings typically requires 30% of the total energy consumption of the building, providing a substantial opportunity for energy savings. To reduce the energy consumed by indoor lighting, we propose a sensor-less light-emitting diode (LED) dimming system using daylight harvesting. In this study, we used light simulation software to quantify and visualize daylight, and analyzed the correlation between photovoltaic (PV) power generation and indoor illumination in an office with an integrated PV system. In addition, we calculated the distribution of daylight illumination into the office and dimming ratios for the individual control of LED lights. Also, we were able directly to use the electric power generated by PV system. As a result, power consumption for electric lighting was reduced by 40 - 70% depending on the season and the weather conditions. Thus, the dimming system proposed in this study can be used to control electric lighting to reduce energy use cost-effectively and simply.
Evolving Our Evaluation of Lighting Environments Project
NASA Technical Reports Server (NTRS)
Terrier, Douglas; Clayton, Ronald; Clark, Toni Anne
2016-01-01
Imagine you are an astronaut on their 100th day of your three year exploration mission. During your daily routine to the small hygiene compartment of the spacecraft, you realize that no matter what you do, your body blocks the light from the lamp. You can clearly see your hands or your toes but not both! What were those design engineers thinking! It would have been nice if they could have made the walls glow instead! The reason the designers were not more innovative is that their interpretation of the system lighting requirements didn't allow them to be so! Currently, our interior spacecraft lighting standards and requirements are written around the concept of a quantity of light illuminating a spacecraft surface. The natural interpretation for the engineer is that a lamp that throws light to the surface is required. Because of certification costs, only one lamp is designed and small rooms can wind up with lamps that may be inappropriate for the room architecture. The advances in solid state light emitting technologies and optics for lighting and visual communication necessitates the evaluation of how NASA envisions spacecraft lighting architectures and how NASA uses industry standards for the design and evaluation of lighting system. Current NASA lighting standards and requirements for existing architectures focus on the separate ability of a lighting system to throw light against a surface or the ability of a display system to provide the appropriate visual contrast. Realization that these systems can be integrated is not realized. The result is that the systems are developed independent from one another and potential efficiencies that could be realized from borrowing from the concept of one technology and applying it for the purpose of the other does not occur. This project investigated the possibility of incorporating large luminous surface lamps as an alternative or supplement to overhead lighting. We identified existing industry standards for architectural luminous or brightness uniformity as part of a lighting system definition. The efficiency of the surface lighting technology was evaluated for uniformity and power consumption. Finally, the team investigated possible performance savings if the walls were made to glow via a self luminous surface system instead of creating brightness by use of direct lighting of a highly reflective diffuse surface.
33 CFR 118.110 - Daymarks and lateral lighting on bridges.
Code of Federal Regulations, 2012 CFR
2012-07-01
... through bridges with U.S. aids to navigation system lateral marks and lights installed on the... flashing, flashing, isophase or occulting red and green lights to mark the main channels. (b) If lateral system lights are required or authorized to mark the main navigation channels, fixed yellow lights shall...
33 CFR 118.110 - Daymarks and lateral lighting on bridges.
Code of Federal Regulations, 2013 CFR
2013-07-01
... through bridges with U.S. aids to navigation system lateral marks and lights installed on the... flashing, flashing, isophase or occulting red and green lights to mark the main channels. (b) If lateral system lights are required or authorized to mark the main navigation channels, fixed yellow lights shall...
33 CFR 118.110 - Daymarks and lateral lighting on bridges.
Code of Federal Regulations, 2014 CFR
2014-07-01
... through bridges with U.S. aids to navigation system lateral marks and lights installed on the... flashing, flashing, isophase or occulting red and green lights to mark the main channels. (b) If lateral system lights are required or authorized to mark the main navigation channels, fixed yellow lights shall...
46 CFR 112.43-15 - Emergency lighting feeders.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Emergency lighting feeders. 112.43-15 Section 112.43-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-15 Emergency lighting feeders. For a vessel with...
46 CFR 112.43-13 - Navigation light indicator panel supply.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Navigation light indicator panel supply. 112.43-13 Section 112.43-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-13 Navigation light indicator panel...
46 CFR 112.43-15 - Emergency lighting feeders.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Emergency lighting feeders. 112.43-15 Section 112.43-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-15 Emergency lighting feeders. For a vessel with...
46 CFR 112.43-13 - Navigation light indicator panel supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Navigation light indicator panel supply. 112.43-13 Section 112.43-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-13 Navigation light indicator panel...
46 CFR 112.43-13 - Navigation light indicator panel supply.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Navigation light indicator panel supply. 112.43-13 Section 112.43-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-13 Navigation light indicator panel...
46 CFR 112.43-13 - Navigation light indicator panel supply.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Navigation light indicator panel supply. 112.43-13 Section 112.43-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-13 Navigation light indicator panel...
46 CFR 112.43-15 - Emergency lighting feeders.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Emergency lighting feeders. 112.43-15 Section 112.43-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-15 Emergency lighting feeders. For a vessel with...
46 CFR 112.43-15 - Emergency lighting feeders.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Emergency lighting feeders. 112.43-15 Section 112.43-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-15 Emergency lighting feeders. For a vessel with...
46 CFR 112.43-15 - Emergency lighting feeders.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Emergency lighting feeders. 112.43-15 Section 112.43-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-15 Emergency lighting feeders. For a vessel with...
46 CFR 112.43-13 - Navigation light indicator panel supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Navigation light indicator panel supply. 112.43-13 Section 112.43-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-13 Navigation light indicator panel...
Portable light detection system for the blind
NASA Technical Reports Server (NTRS)
Wilber, R. L.; Carpenter, B. L.
1973-01-01
System can be used to detect "ready" light on automatic cooking device, to tell if lights are on for visitors, or to tell whether it is daylight or dark outside. Device is actuated like flashlight. Light impinging on photo cell activates transistor which energizes buzzer to indicate presence of light.
Beacon system based on light-emitting diode sources for runways lighting
NASA Astrophysics Data System (ADS)
Montes, Mario González; Vázquez, Daniel; Fernandez-Balbuena, Antonio A.; Bernabeu, Eusebio
2014-06-01
New aeronautical ground lighting techniques are becoming increasingly important to ensure the safety and reduce the maintenance costs of the plane's tracks. Until recently, tracks had embedded lighting systems whose sources were based on incandescent lamps. But incandescent lamps have several disadvantages: high energy consumption and frequent breakdowns that result in high maintenance costs (lamp average life-time is ˜1500 operating hours) and the lamp's technology has a lack of new lighting functions, such as signal handling and modification. To solve these problems, the industry has developed systems based on light-emitting diode (LED) technology with improved features: (1) LED lighting consumes one tenth the power, (2) it improves preventive maintenance (an LED's lifetime range is between 25,000 and 100,000 hours), and (3) LED lighting technology can be controlled remotely according to the needs of the track configuration. LEDs have been in use for more than three decades, but only recently, around 2002, have they begun to be used as visual aids, representing the greatest potential change for airport lighting since their inception in the 1920s. Currently, embedded LED systems are not being broadly used due to the specific constraints of the rules and regulations of airports (beacon dimensions, power system technology, etc.). The fundamental requirements applied to embedded lighting systems are to be hosted on a volume where the dimensions are usually critical and also to integrate all the essential components for operation. An embedded architecture that meets the lighting regulations for airport runways is presented. The present work is divided into three main tasks: development of an optical system to optimize lighting according to International Civil Aviation Organization, manufacturing prototype, and model validation.
Frangioni, John V [Wayland, MA
2012-07-24
A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.
NASA Astrophysics Data System (ADS)
Ma, Chen; Cheng, Dewen; Xu, Chen; Wang, Yongtian
2014-11-01
Fundus camera is a complex optical system for retinal photography, involving illumination and imaging of the retina. Stray light is one of the most significant problems of fundus camera because the retina is so minimally reflective that back reflections from the cornea and any other optical surface are likely to be significantly greater than the light reflected from the retina. To provide maximum illumination to the retina while eliminating back reflections, a novel design of illumination system used in portable fundus camera is proposed. Internal illumination, in which eyepiece is shared by both the illumination system and the imaging system but the condenser and the objective are separated by a beam splitter, is adopted for its high efficiency. To eliminate the strong stray light caused by corneal center and make full use of light energy, the annular stop in conventional illumination systems is replaced by a fiber-coupled, ring-shaped light source that forms an annular beam. Parameters including size and divergence angle of the light source are specially designed. To weaken the stray light, a polarized light source is used, and an analyzer plate is placed after beam splitter in the imaging system. Simulation results show that the illumination uniformity at the fundus exceeds 90%, and the stray light is within 1%. Finally, a proof-of-concept prototype is developed and retinal photos of an ophthalmophantom are captured. The experimental results show that ghost images and stray light have been greatly reduced to a level that professional diagnostic will not be interfered with.
Research on starlight hardware-in-the-loop simulator
NASA Astrophysics Data System (ADS)
Zhang, Ying; Gao, Yang; Qu, Huiyang; Liu, Dongfang; Du, Huijie; Lei, Jie
2016-10-01
The starlight navigation is considered to be one of the most important methods for spacecraft navigation. Starlight simulation system is a high-precision system with large fields of view, designed to test the starlight navigation sensor performance on the ground. A complete hardware-in-the-loop simulation of the system has been built. The starlight simulator is made up of light source, light source controller, light filter, LCD, collimator and control computer. LCD is the key display component of the system, and is installed at the focal point of the collimator. For the LCD cannot emit light itself, so light source and light source power controller is specially designed for the brightness demanded by the LCD. Light filter is designed for the dark background which is also needed in the simulation.
How Things Work: A Light Brighter Than the Sun.
ERIC Educational Resources Information Center
Crane, H. Richard
1996-01-01
Describes the construction of a new lighting system that uses a sulfur light source no bigger than a golf ball that emits enough light for an entire large room. Discusses the theory behind the system. (JRH)
New lighting and controls to save 67% at mall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, K.
1985-06-17
A metal halide lighting system and a Staco control system that dims lighting in response to sunlight should save a Dallas hotel and office mall 67% in electricity costs. The new system replaces quartz lamps in the 160-foot-high atrium. The savings are a combination of state tax credits and lower air conditioning costs, which will pay for the $25,000 project in about 18 months. The metal halide system was chosen over sodium lighting in order to have more attractive color rendition and because it provides about twice as many lumens per watt as the quartz lamps. The Staco system willmore » dim lamps in response to outdoor light and turn lights above a skating rink on and off at prescribed times.« less
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, C.J.; Kross, B.J.; Majewski, S.; Wojcik, R.F.
1998-08-25
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools. 5 figs.
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, Carl J.; Kross, Brian J.; Majewski, Stanislaw; Wojcik, Randolph F.
1998-01-01
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools.
Galloway, Helen; Newman, Emily
2017-03-01
There are contemporary indicators that parent proxy-ratings and child self-ratings of a child's quality of life (QoL) are not interchangeable. This review examines dual informant studies to assess parent-child agreement on the QoL of children with attention-deficit/hyperactivity disorder. A systematic search of four major databases (PsycINFO, MEDLINE, EMBASE and Cochrane databases) was completed, and related peer-reviewed journals were hand-searched. Studies which reported quantitative QoL ratings for matched parent and child dyads were screened in accordance with relevant inclusion and exclusion criteria. Key findings were extracted from thirteen relevant studies, which were rated for conformity to the recommendations of an adapted version of the STROBE statement guidelines for observational studies. In the majority of studies reviewed, children rated their QoL more highly than their parents. There was some evidence for greater agreement on the physical health domain than psychosocial domains.
Mode shape analysis using a commercially available peak store video frame buffer
NASA Technical Reports Server (NTRS)
Snow, Walter L.; Childers, Brooks A.
1994-01-01
Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and resynthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non-integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the 'peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented.
Smith, James; Roberts, Bayard; Knight, Abigail; Gosselin, Richard; Blanchet, Karl
2015-11-01
Humanitarian crises continue to pose a significant threat to health; the United Nations estimates that 144 million people are directly affected by conflict or environmental disasters. During most humanitarian crises, surgical and rehabilitative interventions remain a priority. This review assessed the quality of evidence that informs injury and physical rehabilitation interventions in humanitarian crises. Peer-reviewed and grey literature sources were assessed in a systematic manner. Selected papers were evaluated using quality criteria based on a modified version of the STROBE protocol. 46 papers met the inclusion criteria. 63 % of the papers referred to situations of armed conflict, of which the Yugoslav Wars were the most studied crisis context. 59 % of the studies were published since the year 2000. However, only two studies were considered of a high quality. While there is now a greater emphasis on research in this sector, the volume of evidence remains inadequate given the growing number of humanitarian programmes worldwide. Further research is needed to ensure a greater breadth and depth of understanding of the most appropriate interventions in different settings.
New Approaches for DC Balanced SpaceWire
NASA Technical Reports Server (NTRS)
Kisin, Alex; Rakow, Glenn
2016-01-01
Direct Current (DC) line balanced SpaceWire is attractive for a number of reasons. Firstly, a DC line balanced interface provides the ability to isolate the physical layer with either a transformer or capacitor to achieve higher common mode voltage rejection and/or the complete galvanic isolation in the case of a transformer. Secondly, it provides the possibility to reduce the number of conductors and transceivers in the classical SpaceWire interface by half by eliminating the Strobe line. Depending on the modulator scheme - the clock data recovery frequency requirements may be only twice that of the transmit clock, or even match the transmit clock: depending on the Field Programmable Gate Array (FPGA) decoder design. In this paper, several different implementation scenarios will be discussed. Two of these scenarios are backward compatible with the existing SpaceWire hardware standards except for changes at the character level. Three other scenarios, while decreasing by half the standard SpaceWire hardware components, will require changes at both the character and signal levels and work with fixed rates. Other scenarios with variable data rates will require an additional SpaceWire interface handshake initialization sequence.
Falcone, Denise; Spee, Pieter; van de Kerkhof, Peter C M; van Erp, Piet E J
2017-10-02
Interleukin-1α (IL-1α) and its receptor antagonist IL-1RA play a pivotal role in skin homeostasis and disease. Although the use of biopsies to sample these cytokines from human skin is widely employed in dermatological practice, knowledge about less invasive, in vivo sampling methods is scarce. The aim of this study was to provide an overview of such methods by systematically reviewing studies in Medline, EMBASE, Web of Science and Cochrane Library using combinations of the terms "IL-1α", IL-1RA", "skin", "human", including all possible synonyms. Quality was assessed using the STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) checklist. The search, performed on 14 October 2016, revealed 10 different sampling methods, with varying degrees of invasiveness and wide application spectrum, including assessment of both normal and diseased skin, from several body sites. The possibility to sample quantifiable amounts of cytokines from human skin with no or minimal discomfort holds promise for linking clinical outcomes to molecular profiles of skin inflammation.
The Influence of High-Frequency Envelope Information on Low-Frequency Vowel Identification in Noise
2016-01-01
Vowel identification in noise using consonant-vowel-consonant (CVC) logatomes was used to investigate a possible interplay of speech information from different frequency regions. It was hypothesized that the periodicity conveyed by the temporal envelope of a high frequency stimulus can enhance the use of the information carried by auditory channels in the low-frequency region that share the same periodicity. It was further hypothesized that this acts as a strobe-like mechanism and would increase the signal-to-noise ratio for the voiced parts of the CVCs. In a first experiment, different high-frequency cues were provided to test this hypothesis, whereas a second experiment examined more closely the role of amplitude modulations and intact phase information within the high-frequency region (4–8 kHz). CVCs were either natural or vocoded speech (both limited to a low-pass cutoff-frequency of 2.5 kHz) and were presented in stationary 3-kHz low-pass filtered masking noise. The experimental results did not support the hypothesized use of periodicity information for aiding low-frequency perception. PMID:26730702
AmeriFlux CA-TPD Ontario - Turkey Point Mature Deciduous
Arain, M. Altaf [McMaster University
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site CA-TPD Ontario - Turkey Point Mature Deciduous. Site Description - The forest is approximately 90 years old. Naturally regenerated on sandy terrain and abandoned agricultural land. Predominantly hardwood species with a few scattered conifers. Site has been managed (thinned) in the past. It has a high biodiversity with 573 tree and plant species, 102 bird species, 23 mamal species and 22 reptile and amphibian species (SWALSREP Report, 1999). The dominant tree species is white oak (Quercus alba), with other scattered broadleaf Carolinian species including sugar and red maple (Acer saccharum, A. rubrum), American beech (Fagus grandifolia), black and red oak (Q. velutina, Q. rubra) and white ash (Fraxinus americana) . There are also scattered conifers, mostly white and red pine (Pinus strobes, P. resinosa), comprising about 5% of the trees. Average tree height is 25.7 m with a stand density of 504 ± 18 trees per hectare. Average tree diameter at breast height is 22.3 cm and basal area is 0.06 m2 or approximately 29 square meters per hectare.
A laser-abrasive method for the cutting of enamel and dentin.
Altshuler, G B; Belikov, A V; Sinelnik, Y A
2001-01-01
This paper introduced a new method for the removal of hard dental tissue based upon the use of particles accelerated by laser irradiation, which the authors have called the laser-abrasive method. The particles used were sapphire as powder or an aqueous suspension. The effect of the products of enamel ablation was also investigated. The particles were accelerated using submillisecond pulses of Er:YAG and Nd:YAG lasers. A strobing CCD camera was used to measure the speed of the ejected particles. The additional contribution of these particles to the efficiency of laser ablation of enamel and dentin was also investigated. The results showed that the enamel particles produced by the beam-tissue interaction were also accelerated by this process of ablation and were effective in the removal of enamel and dentin. The use of an aqueous suspension of sapphire particles increased the efficiency of enamel removal threefold when compared with the use of an Er:YAG laser with water spray. The laser-abrasive method allowed for the removal of enamel and dentin at speeds approaching those of the high-speed turbine. Copyright 2001 Wiley-Liss, Inc.
Mode shape analysis using a commercially available "peak-store" video frame buffer
NASA Astrophysics Data System (ADS)
Snow, Walter L.; Childers, Brooks A.
1994-10-01
Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and re synthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the `peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented.
Passive lighting responsive three-dimensional integral imaging
NASA Astrophysics Data System (ADS)
Lou, Yimin; Hu, Juanmei
2017-11-01
A three dimensional (3D) integral imaging (II) technique with a real-time passive lighting responsive ability and vivid 3D performance has been proposed and demonstrated. Some novel lighting responsive phenomena, including light-activated 3D imaging, and light-controlled 3D image scaling and translation, have been realized optically without updating images. By switching the on/off state of a point light source illuminated on the proposed II system, the 3D images can show/hide independent of the diffused illumination background. By changing the position or illumination direction of the point light source, the position and magnification of the 3D image can be modulated in real time. The lighting responsive mechanism of the 3D II system is deduced analytically and verified experimentally. A flexible thin film lighting responsive II system with a 0.4 mm thickness was fabricated. This technique gives some additional degrees of freedom in order to design the II system and enable the virtual 3D image to interact with the real illumination environment in real time.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-1 Purpose. The purpose of this subpart is to define types of emergency lighting and power systems. ...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-1 Purpose. The purpose of this subpart is to define types of emergency lighting and power systems. ...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-1 Purpose. The purpose of this subpart is to define types of emergency lighting and power systems. ...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-1 Purpose. The purpose of this subpart is to define types of emergency lighting and power systems. ...
White-Light Optical Information Processing and Holography.
1985-07-29
this technique is the processing system does not require to carry its own light source. It is very suitable for spaceborne and satellite application. We...developed a technique of generating a spatialtrequency color coded speech spectrogram with a white-light optical system . This system not only offers a low...that the annoying moire fringes can be eliminated. In short, we have once again demonstrated the versatility of the white-light progress system ; a
1998-01-01
A MANUAL FOR A LABORATORY INFORMATION MANAGEMENT SYSTEM (LIMS) FOR LIGHT STABLE ISOTOPES— VERSION 7.0 U.S. GEOLOGICAL SURVEY Open-File Report 98-284...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 A MANUAL FOR A LABORATORY INFORMATION MANAGEMENT SYSTEM (LIMS) FOR LIGHT STABLE...Europa Scientific ..................................................120 1 A MANUAL FOR A LABORATORY INFORMATION MANAGEMENT SYSTEM (LIMS) FOR LIGHT STABLE
Multi-channel automotive night vision system
NASA Astrophysics Data System (ADS)
Lu, Gang; Wang, Li-jun; Zhang, Yi
2013-09-01
A four-channel automotive night vision system is designed and developed .It is consist of the four active near-infrared cameras and an Mulit-channel image processing display unit,cameras were placed in the automobile front, left, right and rear of the system .The system uses near-infrared laser light source,the laser light beam is collimated, the light source contains a thermoelectric cooler (TEC),It can be synchronized with the camera focusing, also has an automatic light intensity adjustment, and thus can ensure the image quality. The principle of composition of the system is description in detail,on this basis, beam collimation,the LD driving and LD temperature control of near-infrared laser light source,four-channel image processing display are discussed.The system can be used in driver assistance, car BLIS, car parking assist system and car alarm system in day and night.
Traffic Light System Can Increase Healthfulness Perception: Implications for Policy Making.
Machín, Leandro; Aschemann-Witzel, Jessica; Curutchet, María Rosa; Giménez, Ana; Ares, Gastón
2018-04-04
To evaluate how information about low nutrient content included in the traffic light labeling system influences consumers' perception of the healthfulness of products with high content of 1 key nutrient, and to compare the traffic light system with warnings in terms of the perception of healthfulness. Images of front-of-pack (FOP) nutrition labels (the traffic light labeling system with different numbers of nutrients with low content, and warnings) were evaluated in study 1, whereas product labels featuring the different FOP nutrition labels were evaluated in study 2. Online studies conducted in Montevideo, Uruguay. A total of 1,228 Uruguayan Facebook users. Perception of healthfulness. The researchers used ANOVA to evaluate the influence of FOP nutrition labels on perceived healthfulness. The inclusion of information about low nutrient content in the traffic light system statistically significantly increased the perception of the healthfulness of products with high nutrient content. Nutritional warnings showed healthfulness ratings similar to those of the simplified version of the traffic light system. Information about low nutrient content in the traffic light system might be used to infer health, and thus could raise the perception of healthfulness and decrease the traffic light system's efficacy in discouraging the consumption of unhealthful products. A simplified version of the traffic light highlighting only high-nutrient content or nutritional warnings seems to overcome this problem. Copyright © 2018 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Adoption of alternative lighting systems to replace traditional incandescent light sources offers the opportunity to tailor lighting systems according to spectral sensitivity needs of different species. Providing a lighting environment that accounts for poultry vision may improve bird welfare and p...
14 CFR 25.1385 - Position light system installation.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Light covers and color filters. Each light cover or color filter must be at least flame resistant and may not change color or shape or lose any appreciable light transmission during normal use. [Doc. No... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light system installation. 25.1385...
46 CFR 35.10-15 - Emergency lighting and power systems-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Emergency lighting and power systems-T/ALL. 35.10-15... Emergency Requirements § 35.10-15 Emergency lighting and power systems—T/ALL. (a) Where fitted, it shall be the duty of the master to see that the emergency lighting and power systems are tested and inspected...
46 CFR 35.10-15 - Emergency lighting and power systems-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Emergency lighting and power systems-T/ALL. 35.10-15... Emergency Requirements § 35.10-15 Emergency lighting and power systems—T/ALL. (a) Where fitted, it shall be the duty of the master to see that the emergency lighting and power systems are tested and inspected...
Rapid prototyping of reflectors for vehicle lighting using laser activated remote phosphor
NASA Astrophysics Data System (ADS)
Lachmayer, Roland; Kloppenburg, Gerolf; Wolf, Alexander
2015-03-01
Bright white light sources are of significant importance for automotive front lighting systems. Today's upper class vehicles mainly use HID or LED as light source. As a further step in this development laser diode based systems offer high luminance, efficiency and allow the realization of new styling concepts and new dynamic lighting functions. These white laser diode systems can either be realized by mixing different spectral sources or by combining diodes with specific phosphors. Based on the approach of generating light using a laser and remote phosphor, lighting modules are manufactured. Four blue laser diodes (450 nm) are used to activate a phosphor coating and thus to achieve white light. A segmented paraboloid reflector generates the desired light distribution for an additional car headlamp. We use high speed milling and selective laser melting to build the reflector system for this lighting module. We compare the spectral reflection grade of these materials. Furthermore the generated modules are analyzed regarding their efficiency and light distribution. The use of Rapid Prototyping technologies allows an early validation of the chosen concept and is supposed to reduce cost and time in the product development process significantly. Therefor we discuss costs and times of the applied manufacturing technologies.
LED Context Lighting System in Residential Areas
Im, Kyoung-Mi
2014-01-01
As issues of environment and energy draw keen interest around the globe due to such problems as global warming and the energy crisis, LED with high optical efficiency is brought to the fore as the next generation lighting. In addition, as the national income level gets higher and life expectancy is extended, interest in the enhancement of life quality is increasing. Accordingly, the trend of lightings is changing from mere adjustment of light intensity to system lighting in order to enhance the quality of one's life as well as reduce energy consumption. Thus, this study aims to design LED context lighting system that automatically recognizes the location and acts of a user in residential areas and creates an appropriate lighting environment. The proposed system designed in this study includes three types of processing: first, the creation of a lighting environment index suitable for the user's surroundings and lighting control scenarios and second, it measures and analyzes the optical characteristics that change depending on the dimming control of lighting and applies them to the index. Lastly, it adopts PIR, piezoelectric, and power sensor to grasp the location and acts of the user and create a lighting environment suitable for the current context. PMID:25101325
DOT National Transportation Integrated Search
2016-07-01
The Virginia Tech Transportation Institute (VTTI) has developed an on-demand roadway lighting : system and has tested the systems effect on driver visual performance. On-demand roadway : lighting can dramatically reduce energy usage while maintain...
Applications of Light-Responsive Systems for Cancer Theranostics.
Chen, Hongzhong; Zhao, Yanli
2018-06-27
Achieving controlled and targeted delivery of chemotherapeutic drugs and other therapeutic agents to tumor sites is challenging. Among many stimulus strategies, light as a mode of action shows various advantages such as high spatiotemporal selectivity, minimal invasiveness and easy operation. Thus, drug delivery systems (DDSs) have been designed with the incorporation of various functionalities responsive to light as an exogenous stimulus. Early development has focused on guiding chemotherapeutic drugs to designated location, followed by the utilization of UV irradiation for controlled drug release. Because of the disadvantages of UV light such as phototoxicity and limited tissue penetration depth, scientists have moved the research focus onto developing nanoparticle systems responsive to light in the visible region (400-700 nm), aiming to reduce the phototoxicity. In order to enhance the tissue penetration depth, near-infrared light triggered DDSs become increasingly important. In addition, light-based advanced systems for fluorescent and photoacoustic imaging, as well as photodynamic and photothermal therapy have also been reported. Herein, we highlight some of recent developments by applying light-responsive systems in cancer theranostics, including light activated drug release, photodynamic and photothermal therapy, and bioimaging techniques such as fluorescent and photoacoustic imaging. Future prospect of light-mediated cancer treatment is discussed at the end of the review. This Spotlights on Applications article aims to provide up-to-date information about the rapidly developing field of light-based cancer theranostics.
[Which colours can we hear?: light stimulation of the hearing system].
Wenzel, G I; Lenarz, T; Schick, B
2014-02-01
The success of conventional hearing aids and electrical auditory prostheses for hearing impaired patients is still limited in noisy environments and for sounds more complex than speech (e. g. music). This is partially due to the difficulty of frequency-specific activation of the auditory system using these devices. Stimulation of the auditory system using light pulses represents an alternative to mechanical and electrical stimulation. Light is a source of energy that can be very exactly focused and applied with little scattering, thus offering perspectives for optimal activation of the auditory system. Studies investigating light stimulation of sectors along the auditory pathway have shown stimulation of the auditory system is possible using light pulses. However, further studies and developments are needed before a new generation of light stimulation-based auditory prostheses can be made available for clinical application.
Il'ina, T N; Vinogradova, I A; Iliukha, V A; Khizhkin, E A; Anisimov, V N; Khavinson, V Kh
2008-01-01
The influences of different light condition, melatonin and epithalon on liver antioxidant system in 6-, 12-, 18- and 24-month-old rats of both sexes were studied. The activities of antioxidant enzymes as well as concentration of tocopherol demonstrate high stability. The maximal number of significant changes in antioxidant system parameters was found under continuous light exposure. Light condition, sex and preparation modulated age-related changes of antioxidant system.
Helicopter Visual Segment Approach Lighting System (HALS) Test Report
1988-08-01
this Pegl 23. Ne. a# Palo$ 22. Ptuco Unclassified Unclassified 316 Form DOT F 1700.7 (8-721 Reproduction of e9Isted Ppe authorized TABLE OF CONTENTS...Subject Pilot Range Rate/Vertical Position Plots lii LIST OF ILLUSTRATIONS Figure Page I Basic Heliport IFR Lighting System 4 2 Heliport Approach...Instrument Flight Rules ( IFR ) Heliport Lighting System and a centerline HALS. The Basic IFR Approach Light System is presented in figure 1. It consists of
Light guide technology: using light to enhance safety
NASA Astrophysics Data System (ADS)
Lerner, William S.
2009-05-01
When used to detect extreme temperatures in harsh environments, warning devices have been placed at a distance from the "danger zone" for several reasons. The inability to mix electricity with flammable, caustic, liquid or volatile substances, the limited heat tolerances exhibited by most light sources, and the susceptibility of light sources to damage from vibration, have made the placement of a warning light directly within these harsh environments impossible. This paper describes a system that utilizes a beam of light to provide just such a warning. This system can be used with hard-wired or wireless sensors, side-light illumination, image projection and image transfer. The entire system may be self-contained and portable.
An Investigation of Laser Lighting Systems to Assist Aircraft
DOT National Transportation Integrated Search
1979-01-01
A model for the visual detectability of narrow light beams was developed and used to evaluate the system performance of two laser lighting system configurations: (1) a laser VASI and (2) a crossed beam glide path indicator. Laboratory experiments con...
Increasing of visibility on the pedestrian crossing by the additional lighting systems
NASA Astrophysics Data System (ADS)
Baleja, Richard; Bos, Petr; Novak, Tomas; Sokansky, Karel; Hanusek, Tomas
2017-09-01
Pedestrian crossings are critical places for road accidents between pedestrians and motor vehicles. For this reason, it is very important to increase attention when the pedestrian crossings are designed and it is necessary to take into account all factors that may contribute to higher safety. Additional lighting systems for pedestrian crossings are one of them and the lighting systems must fulfil the requirements for higher visibility from the point of view of car drivers from both directions. This paper describes the criteria for the suitable additional lighting system on pedestrian crossings. Generally, it means vertical illuminance on the pedestrian crossing from the driver’s view, horizontal illuminance on the crossing and horizontal illuminance both in front of and behind the crossing placed on the road and their acceptable ratios. The article also describes the choice of the colours of the light (correlated colour temperature) and its influence on visibility. As a part of the article, there are case designs of additional lighting systems for pedestrian crossings and measurements from realized additional lighting systems by luxmeters and luminance cameras and their evaluation.
Recent Advances in Cyclodextrin-Based Light-Responsive Supramolecular Systems.
Zhang, Xiaojin; Ma, Xin; Wang, Kang; Lin, Shijun; Zhu, Shitai; Dai, Yu; Xia, Fan
2018-06-01
Cyclodextrins (CDs), one of the host molecules in supramolecular chemistry, can host guest molecules to form inclusion complexes via non-covalent and reversible host-guest interactions. CD-based light-responsive supramolecular systems are typically constructed using CDs and guest molecules with light-responsive moieties, including azobenzene, arylazopyrazole, o-nitrobenzyl ester, pyrenylmethyl ester, coumarin, and anthracene. To date, numerous efforts have been reported on the topic of CD-based light-responsive supramolecular systems, but these have not yet been highlighted in a separated review. This review summarizes the efforts reported over the past ten years. The main text of this review is divided into five sections (vesicles, micelles, gels, capturers, and nanovalves) according to the formation of self-assemblies. This feature article aims to afford a comprehensive understanding of the light-responsive moieties used in the construction of CD-based light-responsive supramolecular systems and to provide a helpful guide for the further design of CD-based light-responsive supramolecular systems. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Lei; Sahi, Sunil K; Peng, Mingying; Lee, Eric B; Ma, Lun; Wojtowicz, Jennifer L; Malin, John H; Chen, Wei
2016-02-10
We developed new optic devices - singly-doped luminescence glasses and nanoparticle-coated lenses that convert UV light to visible light - for improvement of visual system functions. Tb(3+) or Eu(3+) singly-doped borate glasses or CdS-quantum dot (CdS-QD) coated lenses efficiently convert UV light to 542 nm or 613 nm wavelength narrow-band green or red light, or wide-spectrum white light, and thereby provide extra visible light to the eye. In zebrafish (wild-type larvae and adult control animals, retinal degeneration mutants, and light-induced photoreceptor cell degeneration models), the use of Tb(3+) or Eu(3+) doped luminescence glass or CdS-QD coated glass lenses provide additional visible light to the rod and cone photoreceptor cells, and thereby improve the visual system functions. The data provide proof-of-concept for the future development of optic devices for improvement of visual system functions in patients who suffer from photoreceptor cell degeneration or related retinal diseases.
NASA Technical Reports Server (NTRS)
Clark, T. A.; Brainard, G.; Salazar, G.; Johnston, S.; Schwing, B.; Litaker, H.; Kolomenski, A.; Venus, D.; Tran, K.; Hanifin, J.;
2017-01-01
NASA has demonstrated an interest in improving astronaut health and performance through the installment of a new lighting countermeasure on the International Space Station. The Solid State Lighting Assembly (SSLA) system is designed to positively influence astronaut health by providing a daily change to light spectrum to improve circadian entrainment. Unfortunately, existing NASA standards and requirements define ambient light level requirements for crew sleep and other tasks, yet the number of light-emitting diode (LED) indicators and displays within a habitable volume is currently uncontrolled. Because each of these light sources has its own unique spectral properties, the additive lighting environment ends up becoming something different from what was planned or researched. Restricting the use of displays and indicators is not a solution because these systems provide beneficial feedback to the crew. The research team for this grant used computer-based computational modeling and real-world lighting mockups to document the impact that light sources other than the ambient lighting system contribute to the ambient spectral lighting environment. In particular, the team was focused on understanding the impacts of long-term tasks located in front of avionics or computer displays. The team also wanted to understand options for mitigating the changes to the ambient light spectrum in the interest of maintaining the performance of a lighting countermeasure. The project utilized a variety of physical and computer-based simulations to determine direct relationships between system implementation and light spectrum. Using real-world data, computer models were built in the commercially available optics analysis software Zemax Optics Studio(c). The team also built a mockup test facility that had the same volume and configuration as one of the Zemax models. The team collected over 1200 spectral irradiance measurements, each representing a different configuration of the mockup. Analysis of the data showed a measurable impact on ambient light spectrum. This data showed that obvious design techniques exist that can be used to bind the ambient light spectrum closer to the planned spectral operating environment for the observer's eye point. The following observations should be considered when designing an operational environment that is dominated by computer displays. When more light is directed into the field of view of the observer, the greater the impact it will make on various human factors issues that depend on spectral shape and intensity. Because viewing angle has a large part to play in the amount of light flux on the crewmember's retina, beam shape, combined with light source location is an important factor for determining percent probable incident flux on the observer from any combination of light sources. Computer graphics design and display lumen output are major factors influencing the amount of spectrally intense light projected into the environment and in the viewer's direction. Use of adjustable white point display software was useful only if the predominant background color was white and if it matched the ambient light system's color. Display graphics that used a predominantly black background had the least influence on unplanned spectral energy projected into the environment. Percent reflectance makes a difference in total energy reflected back into an environment, and within certain architectural geometries, reflectance can be used to control the amount of a light spectrum that is allowed to perpetuate in the environment. Data showed that room volume and distance from significant light sources influence the total spectrum in a room. Smaller environments had a homogenizing effect on total light spectrum, whereas light from multiple sources in larger environments was less mixed. The findings indicated above should be considered when making recommendations for practice or standards for architectural systems. The ambient lighting system, surface reflectance, and display and indicator implementation all factor into the users' spectral environment. A variety of low-cost solutions exist to mitigate the impact of light from non-architectural lighting systems, and much potential for system automation and integration of display systems with the ambient environment. This team believes that proper planning can be used to avoid integration problems and also believes that human-in-the-loop evaluations, real-world test and measurement, and computer modeling can be used to determine how changes to a process, display graphics, and architecture will help maintain the planned spectral operating lighting environment.
Optical Fiber Illumination System for visual flight simulation
NASA Technical Reports Server (NTRS)
Hollow, R. H.
1981-01-01
An electronically controlled lighting system simulating runway, aircraft carrier, and landing aid lights for flight simulations is described. The various colored lights that would be visible to a pilot by day, at dusk, or at night are duplicated at the distances the lights would normally become visible. Plastic optical fiber illuminators using tungsten halogen lights are distributed behind the model. The tips of the fibers of illuminators simulating runway lights are bevelled in order that they may be seen from long distances and at low angles. Fibers representing taxiway lights are pointed and polished for omni-directional visibility. The electronic intensity controls, which can be operated either manually or remotely, regulate the intensity of the lights to simulate changes in distance. A dichronic mirror, infrared filter system is used to maintain color integrity.
Sugimura, Daisuke; Kobayashi, Suguru; Hamamoto, Takayuki
2017-11-01
Light field imaging is an emerging technique that is employed to realize various applications such as multi-viewpoint imaging, focal-point changing, and depth estimation. In this paper, we propose a concept of a dual-resolution light field imaging system to synthesize super-resolved multi-viewpoint images. The key novelty of this study is the use of an organic photoelectric conversion film (OPCF), which is a device that converts spectra information of incoming light within a certain wavelength range into an electrical signal (pixel value), for light field imaging. In our imaging system, we place the OPCF having the green spectral sensitivity onto the micro-lens array of the conventional light field camera. The OPCF allows us to acquire the green spectra information only at the center viewpoint with the full resolution of the image sensor. In contrast, the optical system of the light field camera in our imaging system captures the other spectra information (red and blue) at multiple viewpoints (sub-aperture images) but with low resolution. Thus, our dual-resolution light field imaging system enables us to simultaneously capture information about the target scene at a high spatial resolution as well as the direction information of the incoming light. By exploiting these advantages of our imaging system, our proposed method enables the synthesis of full-resolution multi-viewpoint images. We perform experiments using synthetic images, and the results demonstrate that our method outperforms other previous methods.
33 CFR 127.1109 - Lighting systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Lighting systems. 127.1109 Section 127.1109 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1109 Lighting systems...
33 CFR 127.1109 - Lighting systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Lighting systems. 127.1109 Section 127.1109 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1109 Lighting systems...
33 CFR 127.1109 - Lighting systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Lighting systems. 127.1109 Section 127.1109 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1109 Lighting systems...
33 CFR 127.1109 - Lighting systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Lighting systems. 127.1109 Section 127.1109 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1109 Lighting systems...
Hybrid solar lighting systems and components
Muhs, Jeffrey D [Lenoir City, TN; Earl, Dennis D [Knoxville, TN; Beshears, David L [Knoxville, TN; Maxey, Lonnie C [Powell, TN; Jordan, John K [Oak Ridge, TN; Lind, Randall F [Lenoir City, TN
2007-06-12
A hybrid solar lighting system and components having at least one hybrid solar concentrator, at least one fiber receiver, at least one hybrid luminaire, and a light distribution system operably connected to each hybrid solar concentrator and each hybrid luminaire. A controller operates each component.
33 CFR 127.1109 - Lighting systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Lighting systems. 127.1109 Section 127.1109 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1109 Lighting systems...
A novel optical system design of light field camera
NASA Astrophysics Data System (ADS)
Wang, Ye; Li, Wenhua; Hao, Chenyang
2016-01-01
The structure of main lens - Micro Lens Array (MLA) - imaging sensor is usually adopted in optical system of light field camera, and the MLA is the most important part in the optical system, which has the function of collecting and recording the amplitude and phase information of the field light. In this paper, a novel optical system structure is proposed. The novel optical system is based on the 4f optical structure, and the micro-aperture array (MAA) is used to instead of the MLA for realizing the information acquisition of the 4D light field. We analyze the principle that the novel optical system could realize the information acquisition of the light field. At the same time, a simple MAA, line grating optical system, is designed by ZEMAX software in this paper. The novel optical system is simulated by a line grating optical system, and multiple images are obtained in the image plane. The imaging quality of the novel optical system is analyzed.
Improved spring model-based collaborative indoor visible light positioning
NASA Astrophysics Data System (ADS)
Luo, Zhijie; Zhang, WeiNan; Zhou, GuoFu
2016-06-01
Gaining accuracy with indoor positioning of individuals is important as many location-based services rely on the user's current position to provide them with useful services. Many researchers have studied indoor positioning techniques based on WiFi and Bluetooth. However, they have disadvantages such as low accuracy or high cost. In this paper, we propose an indoor positioning system in which visible light radiated from light-emitting diodes is used to locate the position of receivers. Compared with existing methods using light-emitting diode light, we present a high-precision and simple implementation collaborative indoor visible light positioning system based on an improved spring model. We first estimate coordinate position information using the visible light positioning system, and then use the spring model to correct positioning errors. The system can be employed easily because it does not require additional sensors and the occlusion problem of visible light would be alleviated. We also describe simulation experiments, which confirm the feasibility of our proposed method.
Active Beam Shaping System and Method Using Sequential Deformable Mirrors
NASA Technical Reports Server (NTRS)
Pueyo, Laurent A. (Inventor); Norman, Colin A. (Inventor)
2015-01-01
An active optical beam shaping system includes a first deformable mirror arranged to at least partially intercept an entrance beam of light and to provide a first reflected beam of light, a second deformable mirror arranged to at least partially intercept the first reflected beam of light from the first deformable mirror and to provide a second reflected beam of light, and a signal processing and control system configured to communicate with the first and second deformable mirrors. The first deformable mirror, the second deformable mirror and the signal processing and control system together provide a large amplitude light modulation range to provide an actively shaped optical beam.
Design of light guide sleeve on hyperspectral imaging system for skin diagnosis
NASA Astrophysics Data System (ADS)
Yan, Yung-Jhe; Chang, Chao-Hsin; Huang, Ting-Wei; Chiang, Hou-Chi; Wu, Jeng-Fu; Ou-Yang, Mang
2017-08-01
A hyperspectral imaging system is proposed for early study of skin diagnosis. A stable and high hyperspectral image quality is important for analysis. Therefore, a light guide sleeve (LGS) was designed for the embedded on a hyperspectral imaging system. It provides a uniform light source on the object plane with the determined distance. Furthermore, it can shield the ambient light from entering the system and increasing noise. For the purpose of producing a uniform light source, the LGS device was designed in the symmetrical double-layered structure. It has light cut structures to adjust distribution of rays between two layers and has the Lambertian surface in the front-end to promote output uniformity. In the simulation of the design, the uniformity of illuminance was about 91.7%. In the measurement of the actual light guide sleeve, the uniformity of illuminance was about 92.5%.
Optimal integration of daylighting and electric lighting systems using non-imaging optics
NASA Astrophysics Data System (ADS)
Scartezzini, J.-L.; Linhart, F.; Kaegi-Kolisnychenko, E.
2007-09-01
Electric lighting is responsible for a significant fraction of electricity consumption within non-residential buildings. Making daylight more available in office and commercial buildings can lead as a consequence to important electricity savings, as well as to the improvement of occupants' visual performance and wellbeing. Over the last decades, daylighting technologies have been developed for that purpose, some of them having proven to be highly efficient such as anidolic daylighting systems. Based on non-imaging optics these optical devices were designed to achieve an efficient collection and redistribution of daylight within deep office rooms. However in order to benefit from the substantial daylight provision obtained through these systems and convert it into effective electricity savings, novel electric lighting strategies are required. An optimal integration of high efficacy light sources and efficient luminaries based on non-imaging optics with anidolic daylighting systems can lead to such novel strategies. Starting from the experience gained through the development of an Anidolic Integrated Ceiling (AIC), this paper presents an optimal integrated daylighting and electric lighting system. Computer simulations based on ray-tracing techniques were used to achieve the integration of 36W fluorescent tubes and non-imaging reflectors with an advanced daylighting system. Lighting power densities lower than 4 W/m2 can be achieved in this way within the corresponding office room. On-site monitoring of an integrated daylighting and electric lighting system carried out on a solar experimental building confirmed the energy and visual performance of such a system: it showed that low lighting power densities can be achieved by combining an anidolic daylighting system with very efficient electric light sources and luminaries.
Is White Light the Best Illumination for Palmprint Recognition?
NASA Astrophysics Data System (ADS)
Guo, Zhenhua; Zhang, David; Zhang, Lei
Palmprint as a new biometric has received great research attention in the past decades. It owns many merits, such as robustness, low cost, user friendliness, and high accuracy. Most of the current palmprint recognition systems use an active light to acquire clear palmprint images. Thus, light source is a key component in the system to capture enough of discriminant information for palmprint recognition. To the best of our knowledge, white light is the most widely used light source. However, little work has been done on investigating whether white light is the best illumination for palmprint recognition. In this study, we empirically compared palmprint recognition accuracy using white light and other six different color lights. The experiments on a large database show that white light is not the optimal illumination for palmprint recognition. This finding will be useful to future palmprint recognition system design.
NASA Astrophysics Data System (ADS)
Kenar, Necla; Lim, H. S.; Mirzaaghasi, Amin
2014-02-01
New design of the excitation light source that can stably generate light with center wavelengths of 450nm, 530nm, 632.8nm and white light for auto-fluorescence(AF) and photodynamic diagnosis(PDD) of cancer in clinics in a single system is presented in this study. The light source consists of Xenon Lamp (300W), light guide module including motorize filter wheel equipped with optical filters with corresponding to wavelength bands, servo motor, motorize iris, a cooling system, power supply and optical transmission part for the output light. The transmission part of the light source was developed to collimate the light with desired wavelength into input of fiber optic. Output powers are obtained average 99.91 mW for 450+/-40 nm, 111.01 mW for 530+/-10nm, and 78.50 mW for 632.8+/-10nm.
Ferns, mosses and liverworts as model systems for light-mediated chloroplast movements.
Suetsugu, Noriyuki; Higa, Takeshi; Wada, Masamitsu
2017-11-01
Light-induced chloroplast movement is found in most plant species, including algae and land plants. In land plants with multiple small chloroplasts, under weak light conditions, the chloroplasts move towards the light and accumulate on the periclinal cell walls to efficiently perceive light for photosynthesis (the accumulation response). Under strong light conditions, chloroplasts escape from light to avoid photodamage (the avoidance response). In most plant species, blue light induces chloroplast movement, and phototropin receptor kinases are the blue light receptors. Molecular mechanisms for photoreceptors, signal transduction and chloroplast motility systems are being studied using the model plant Arabidopsis thaliana. However, to further understand the molecular mechanisms and evolutionary history of chloroplast movement in green plants, analyses using other plant systems are required. Here, we review recent works on chloroplast movement in green algae, liverwort, mosses and ferns that provide new insights on chloroplast movement. © 2016 John Wiley & Sons Ltd.
Multi-pass amplifier architecture for high power laser systems
Manes, Kenneth R; Spaeth, Mary L; Erlandson, Alvin C
2014-04-01
A main amplifier system includes a first reflector operable to receive input light through a first aperture and direct the input light along an optical path. The input light is characterized by a first polarization. The main amplifier system also includes a first polarizer operable to reflect light characterized by the first polarization state. The main amplifier system further includes a first and second set of amplifier modules. Each of the first and second set of amplifier modules includes an entrance window, a quarter wave plate, a plurality of amplifier slablets arrayed substantially parallel to each other, and an exit window. The main amplifier system additionally includes a set of mirrors operable to reflect light exiting the first set of amplifier modules to enter the second set of amplifier modules and a second polarizer operable to reflect light characterized by a second polarization state.
NASA Astrophysics Data System (ADS)
Yamamoto, Seiichi; Suzuki, Mayumi; Kato, Katsuhiko; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Ogata, Yoshimune; Hatazawa, Jun
2016-09-01
Although iodine 131 (I-131) is used for radionuclide therapy, high resolution images are difficult to obtain with conventional gamma cameras because of the high energy of I-131 gamma photons (364 keV). Cerenkov-light imaging is a possible method for beta emitting radionuclides, and I-131 (606 MeV maximum beta energy) is a candidate to obtain high resolution images. We developed a high energy gamma camera system for I-131 radionuclide and combined it with a Cerenkov-light imaging system to form a gamma-photon/Cerenkov-light hybrid imaging system to compare the simultaneously measured images of these two modalities. The high energy gamma imaging detector used 0.85-mm×0.85-mm×10-mm thick GAGG scintillator pixels arranged in a 44×44 matrix with a 0.1-mm thick reflector and optical coupled to a Hamamatsu 2 in. square position sensitive photomultiplier tube (PSPMT: H12700 MOD). The gamma imaging detector was encased in a 2 cm thick tungsten shield, and a pinhole collimator was mounted on its top to form a gamma camera system. The Cerenkov-light imaging system was made of a high sensitivity cooled CCD camera. The Cerenkov-light imaging system was combined with the gamma camera using optical mirrors to image the same area of the subject. With this configuration, we simultaneously imaged the gamma photons and the Cerenkov-light from I-131 in the subjects. The spatial resolution and sensitivity of the gamma camera system for I-131 were respectively 3 mm FWHM and 10 cps/MBq for the high sensitivity collimator at 10 cm from the collimator surface. The spatial resolution of the Cerenkov-light imaging system was 0.64 mm FWHM at 10 cm from the system surface. Thyroid phantom and rat images were successfully obtained with the developed gamma-photon/Cerenkov-light hybrid imaging system, allowing direct comparison of these two modalities. Our developed gamma-photon/Cerenkov-light hybrid imaging system will be useful to evaluate the advantages and disadvantages of these two modalities.
Hybrid solar lighting distribution systems and components
Muhs, Jeffrey D [Lenoir City, TN; Earl, Dennis D [Knoxville, TN; Beshears, David L [Knoxville, TN; Maxey, Lonnie C [Powell, TN; Jordan, John K [Oak Ridge, TN; Lind, Randall F [Lenoir City, TN
2011-07-05
A hybrid solar lighting distribution system and components having at least one hybrid solar concentrator, at least one fiber receiver, at least one hybrid luminaire, and a light distribution system operably connected to each hybrid solar concentrator and each hybrid luminaire. A controller operates all components.
14 CFR 29.812 - Emergency lighting.
Code of Federal Regulations, 2010 CFR
2010-01-01
... lighting system, they may be recharged from the rotorcraft's main electrical power system provided the... power supply independent of the main lighting system must be installed to— (1) Illuminate each passenger... upon interruption of the rotorcraft's normal electric power. (d) Any means required to assist the...
47 CFR 17.56 - Maintenance of lighting equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... § 17.56 Maintenance of lighting equipment. (a) Replacing or repairing of lights, automatic indicators or automatic control or alarm systems shall be accomplished as soon as practicable. (b) The flash tubes in a high intensity obstruction lighting system shall be replaced whenever the peak effective...
ERIC Educational Resources Information Center
Murphy, Peter
1997-01-01
Details the dramatic changes in school lighting. Describes how lighting will be more closely integrated into the "smart" school building of tomorrow and how lighting systems will evolve with schools as technology changes. Claims that direct/indirect lighting systems will serve computer users as well as reduce energy and maintenance costs. (RJM)
Stray light suppression of optical and mechanical system for telescope detection
NASA Astrophysics Data System (ADS)
Wang, Lei; Ma, Wenli
2013-09-01
During telescope detection, there is atmosphere overflow and other stray light affecting the system which leads to background disturbance. Thus reduce the detection capability of the system. So it is very necessary to design mechanical structure to suppress the stray light for the telescope detection system. It can both improve the signal-to-noise and contrast of the object. This paper designs the optical and mechanical structure of the 400mm telescope. And then the main baffle, baffle vane, field stop and coating technology are used to eliminate the effect of stray light on the optical and mechanical system. Finally, software is used to analyze and simulate stray light on the whole optical and mechanical system. Using PST as the evaluating standard, separate and integrated analysis of the suppressing effect of main baffle, baffle vane and field aperture is completed. And also get the results of PST before and after eliminating the stray light. Meanwhile, the results of stray light analysis can be used to guide the design of the optical and mechanical structure. The analysis results demonstrate that reasonable optical and mechanical structure and stray light suppression measure can highly reduce the PST and also improve the detection capability of the telescope system, and the designed outside baffle, inside baffle, vanes and coating technique etc. can decrease the PST approximately 1 to 3 level.
Light-switchable systems for remotely controlled drug delivery.
Shim, Gayong; Ko, Seungbeom; Kim, Dongyoon; Le, Quoc-Viet; Park, Gyu Thae; Lee, Jaiwoo; Kwon, Taekhyun; Choi, Han-Gon; Kim, Young Bong; Oh, Yu-Kyoung
2017-12-10
Light-switchable systems have recently received attention as a new mode of remotely controlled drug delivery. In the past, a multitude of nanomedicine studies have sought to enhance the specificity of drug delivery to target sites by focusing on receptors overexpressed on malignant cells or environmental features of diseases sites. Despite these immense efforts, however, there are few clinically available nanomedicines. We need a paradigm shift in drug delivery. One strategy that may overcome the limitations of pathophysiology-based drug delivery is the use of remotely controlled delivery technology. Unlike pathophysiology-based active drug targeting strategies, light-switchable systems are not affected by the heterogeneity of cells, tissue types, and/or microenvironments. Instead, they are triggered by remote light (i.e., near-infrared) stimuli, which are absorbed by photoresponsive molecules or three-dimensional nanostructures. The sequential conversion of light to heat or reactive oxygen species can activate drug release and allow it to be spatio-temporally controlled. Light-switchable systems have been used to activate endosomal drug escape, modulate the release of chemical and biological drugs, and alter nanoparticle structures to control the release rates of drugs. This review will address the limitations of pathophysiology-based drug delivery systems, the current status of light-based remote-switch systems, and future directions in the application of light-switchable systems for remotely controlled drug delivery. Copyright © 2017 Elsevier B.V. All rights reserved.
Ground and space flight experiments of the effects of light, sound and/or temperature on animals
NASA Technical Reports Server (NTRS)
Holley, Daniel C.; Du, Vince; Erikson, Jill; Gott, Jack; Hinchcliffe, Heather; Mele, Gary; Moeller, Karen; Nguyen, Tam; Okumura, Sarah; Robbins, Mark
1994-01-01
Papers on the following topics are presented: (1) rat long term habitability and breeding under low light intensity (5 lux); (2) effects of low light intensity on the rat circadian system; (3) effects of sound/noise on the circadian system of rats; (4) temperature related problems involving the animal enclosure modules (AEM) lighting system; and (5) NASA AEM filter test 92/93 (Rats).
Benefits of glass fibers in solar fiber optic lighting systems.
Volotinen, Tarja T; Lingfors, David H S
2013-09-20
The transmission properties and coupling of solar light have been studied for glass core multimode fibers in order to verify their benefits for a solar fiber optic lighting system. The light transportation distance can be extended from 20 m with plastic fibers to over 100 m with the kind of glass fibers studied here. A high luminous flux, full visible spectrum, as well as an outstanding color rendering index (98) and correlated color temperature similar to the direct sun light outside have been obtained. Thus the outstanding quality of solar light transmitted through these fibers would improve the visibility of all kinds of objects compared to fluorescent and other artificial lighting. Annual relative lighting energy savings of 36% in Uppsala, Sweden, and 76% in Dubai were estimated in an office environment. The absolute savings can be doubled by using glass optical fibers, and are estimated to be in the order of 550 kWh/year in Sweden and 1160 kWh/year in Dubai for one system of only 0.159 m(2) total light collecting area. The savings are dependent on the fiber length, the daily usage time of the interior, the type of artificial lighting substituted, the system light output flux, and the available time of sunny weather at the geographic location.
An intraocular micro light-emitting diode device for endo-illumination during pars plana vitrectomy.
Koelbl, Philipp S; Lingenfelder, Christian; Spraul, Christoph W; Kampmeier, Juergen; Koch, Frank Hj; Kim, Yong Keun; Hessling, Martin
2018-03-01
Development of a new, fiber-free, single-use endo-illuminator for pars plana vitrectomy as a replacement for fiber-based systems with external light sources. The hand-guided intraocularly placed white micro light-emitting diode is evaluated for its illumination properties and potential photochemical and thermal hazards. A micro light-emitting diode was used to develop a single-use intraocular illumination system. The light-source-on-tip device was implemented in a prototype with 23G trocar compatible outer diameter of 0.6 mm. The experimental testing was performed on porcine eyes. All calculations of possible photochemical and thermal hazards during the application of the intraocular micro light-emitting diode were calculated according to DIN EN ISO 15007-2: 2014. The endo-illuminator generated a homogeneous and bright illumination of the intraocular space. The color impression was physiologic and natural. Contrary to initial apprehension, the possible risk caused by inserting a light-emitting diode into the intraocular vitreous was much smaller when compared to conventional fiber-based illumination systems. The photochemical and thermal hazards allowed a continuous exposure time to the retina of at least 4.7 h. This first intraocular light source showed that a light-emitting diode can be introduced into the eye. The system can be built as single-use illumination system. This light-source-on-tip light-emitting diode-endo-illumination combines a chandelier wide-angle illumination with an adjustable endo-illuminator.
An Illumination Modeling System for Human Factors Analyses
NASA Technical Reports Server (NTRS)
Huynh, Thong; Maida, James C.; Bond, Robert L. (Technical Monitor)
2002-01-01
Seeing is critical to human performance. Lighting is critical for seeing. Therefore, lighting is critical to human performance. This is common sense, and here on earth, it is easily taken for granted. However, on orbit, because the sun will rise or set every 45 minutes on average, humans working in space must cope with extremely dynamic lighting conditions. Contrast conditions of harsh shadowing and glare is also severe. The prediction of lighting conditions for critical operations is essential. Crew training can factor lighting into the lesson plans when necessary. Mission planners can determine whether low-light video cameras are required or whether additional luminaires need to be flown. The optimization of the quantity and quality of light is needed because of the effects on crew safety, on electrical power and on equipment maintainability. To address all of these issues, an illumination modeling system has been developed by the Graphics Research and Analyses Facility (GRAF) and Lighting Environment Test Facility (LETF) in the Space Human Factors Laboratory at NASA Johnson Space Center. The system uses physically based ray tracing software (Radiance) developed at Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system (PLAID) and an extensive database of humans and environments. Material reflectivity properties of major surfaces and critical surfaces are measured using a gonio-reflectometer. Luminaires (lights) are measured for beam spread distribution, color and intensity. Video camera performances are measured for color and light sensitivity. 3D geometric models of humans and the environment are combined with the material and light models to form a system capable of predicting lighting conditions and visibility conditions in space.
Chatelle, Claire; Ochoa-Fernandez, Rocio; Engesser, Raphael; Schneider, Nils; Beyer, Hannes M; Jones, Alex R; Timmer, Jens; Zurbriggen, Matias D; Weber, Wilfried
2018-05-18
The ever-increasing complexity of synthetic gene networks and applications of synthetic biology requires precise and orthogonal gene expression systems. Of particular interest are systems responsive to light as they enable the control of gene expression dynamics with unprecedented resolution in space and time. While broadly used in mammalian backgrounds, however, optogenetic approaches in plant cells are still limited due to interference of the activating light with endogenous photoreceptors. Here, we describe the development of the first synthetic light-responsive system for the targeted control of gene expression in mammalian and plant cells that responds to the green range of the light spectrum in which plant photoreceptors have minimal activity. We first engineered a system based on the light-sensitive bacterial transcription factor CarH and its cognate DNA operator sequence CarO from Thermus thermophilus to control gene expression in mammalian cells. The system was functional in various mammalian cell lines, showing high induction (up to 350-fold) along with low leakiness, as well as high reversibility. We quantitatively described the systems characteristics by the development and experimental validation of a mathematical model. Finally, we transferred the system into A. thaliana protoplasts and demonstrated gene repression in response to green light. We expect that this system will provide new opportunities in applications based on synthetic gene networks and will open up perspectives for optogenetic studies in mammalian and plant cells.
Fiber optic spectroscopic digital imaging sensor and method for flame properties monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelepouga, Serguei A; Rue, David M; Saveliev, Alexei V
2011-03-15
A system for real-time monitoring of flame properties in combustors and gasifiers which includes an imaging fiber optic bundle having a light receiving end and a light output end and a spectroscopic imaging system operably connected with the light output end of the imaging fiber optic bundle. Focusing of the light received by the light receiving end of the imaging fiber optic bundle by a wall disposed between the light receiving end of the fiber optic bundle and a light source, which wall forms a pinhole opening aligned with the light receiving end.
Light valve based on nonimaging optics with potential application in cold climate greenhouses
NASA Astrophysics Data System (ADS)
Valerio, Angel A.; Mossman, Michele A.; Whitehead, Lorne A.
2014-09-01
We have evaluated a new concept for a variable light valve and thermal insulation system based on nonimaging optics. The system incorporates compound parabolic concentrators and can readily be switched between an open highly light transmissive state and a closed highly thermally insulating state. This variable light valve makes the transition between high thermal insulation and efficient light transmittance practical and may be useful in plant growth environments to provide both adequate sunlight illumination and thermal insulation as needed. We have measured light transmittance values exceeding 80% for the light valve design and achieved thermal insulation values substantially exceeding those of traditional energy efficient windows. The light valve system presented in this paper represents a potential solution for greenhouse food production in locations where greenhouses are not feasible economically due to high heating cost.
Wide acceptance angle, high concentration ratio, optical collector
NASA Technical Reports Server (NTRS)
Kruer, Mark A. (Inventor)
1991-01-01
A cassegrain optical system provides improved collection of off-axis light yet is still characterized by a high concentration ratio. The optical system includes a primary mirror for collecting incoming light and reflecting the light to a secondary mirror which, in turn, reflects the light to a solar cell or other radiation collection device. The primary mirror reflects incoming on-axis light onto an annular section of the secondary mirror and results in the reflection of a substantial amount of incoming off-axis light onto the remainder of the secondary mirror. Thus light which would otherwise be lost to the system will be captured by the collector. Furthermore, the off-axis sections of the secondary mirror may be of a different geometrical shape than the on-axis annular section so as to optimize the amount of off-axis light collected.
ERIC Educational Resources Information Center
Modern Schools, 1973
1973-01-01
The trend toward increased lighting has accelerated the acceptance of heat recovery systems. A heating-lighting-cooling system is a responsible and efficient use of energy for future school buildings. (Author/MLF)
Status of Solid State Lighting Product Development and Future Trends for General Illumination.
Katona, Thomas M; Pattison, P Morgan; Paolini, Steve
2016-06-07
After decades of research and development on fabrication of efficient light-emitting diodes (LEDs) throughout the visible spectrum, LED-based lighting has reached unparalleled performance with respect to energy efficiency and has become the light source for virtually all new lighting products being designed today. The development of the core light sources and their subsequent integration into lighting systems continue to present unique challenges and opportunities for product designers. We review these systems and the current development status, as well as provide context for the trends in solid state lighting that are leading to the development of value-added lighting solutions that extend the domain of lighting beyond light generation, into fields as diverse as communications, healthcare, and agricultural production.
Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linhart, Friedrich; Scartezzini, Jean-Louis
2010-04-15
Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of lessmore » than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)« less
NASA Astrophysics Data System (ADS)
Mügge, Martin; Hohmann, Carsten
2016-04-01
Signal functions have to fulfill statutory regulations such as ECE or FMVSS108 to provide a clear signal to other road users and satisfy the same standard definitions of lighting parameters. However, as rear combination lamps are very different from one another, and these days are an increasingly powerful design element of cars, automotive manufacturers want an innovative, superior, and contrasting design. Daytime appearances with a new and unusual look and nighttime appearances with unexpected illumination are strong drivers for developing amazing innovative signal functions. The combination of LED technology and different forms of light-guiding optics, new interpretations of common optical systems to develop various styling options, the use of new materials and components for lighting effects, the introduction of OLED technology on the automotive market, and amazing new optical systems, using diffractive or holographic optics in future rear lamps, are paving the way for further, exciting design possibilities. The challenge of new signal functions is to take these possibilities and to develop the appearance and illumination effects the designer wants to reinforce the image of the car manufacturer and to fit harmoniously into the vehicle design. Lighting systems with a three-dimensional design and appearance when unlit and lit, amazing 3D effects, and surprising lighting scenarios will gain in importance. But the signal lights on cars will, in the future, be not only lighting functions in rear lamps; new functions and stylistic illuminations for coming/leaving-home scenarios will support and complete the car's overall lighting appearance. This paper describes current lighting systems realizing the styling requirements and future lighting systems offering new design possibilities and developing further stylistic, visual effects and improved technologies.
14 CFR 23.1401 - Anticollision light system.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., but not 180, cycles per minute. (d) Color. Each anticollision light must be either aviation red or... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Anticollision light system. 23.1401 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1401...
14 CFR 23.1401 - Anticollision light system.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., but not 180, cycles per minute. (d) Color. Each anticollision light must be either aviation red or... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Anticollision light system. 23.1401 Section... AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1401...
33 CFR 62.45 - Light characteristics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Light characteristics. 62.45... NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.45 Light characteristics. (a) Lights on aids to navigation are differentiated by color and rhythm. Lighthouses and range...
33 CFR 62.45 - Light characteristics.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Light characteristics. 62.45... NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.45 Light characteristics. (a) Lights on aids to navigation are differentiated by color and rhythm. Lighthouses and range...