The Liquid State and Its Electrical Properties
1988-01-01
system. At any instant, the density will deviate from its average, and the deviation of one position r will affect that at another position r’. These...and treats the affect of the sizes of the ions incompletely. The limiting law slopes and deviations from them depend strongly on the temperature and...2,2,4-trimethylpentane, pressure increases the mobility by 30-40% at room temperature, affects little change at temperatures near 60*, and decreases
Head-body righting reflex from the supine position and preparatory eye movements.
Troiani, Diana; Ferraresi, Aldo; Manni, Ermanno
2005-05-01
Saccular and utricular maculae can provide information on the supine static position, considering that both have pronounced curved structures with hair cells having a variety of polarization vectors that enable them to sense an inverted position and thus direct the righting reflex. The vestibular system is essential for the structuring of motor behaviour, senses linear and angular acceleration and has a strong influence on posture and balance at rest, during locomotion and in head body righting reflexes. Using guinea pigs in the supine position with a symmetrical head and trunk position, the ocular position was analysed to ascertain whether any ocular movement that occurred would adopt a spatial deviation indicative of the subsequent head and body righting. The characteristics of the righting reflex (direction, latency, duration and velocity) were analysed in guinea pigs from position signals obtained from search coils implanted in the eye, head and pelvis. The animals were kept in a supine position for a few seconds or even minutes with the eyes in a stable primary position and the head and body symmetrical and immobile. The righting reflex took place either immediately or after a slow deviation of the eyes. In both cases the righting sequence (eyes, head, body) was stereotyped and consistent. The direction of head and body righting was along the longitudinal axis of the animal and was either clockwise or anticlockwise and the direction of righting was related to the direction of the eye deviation. The ocular deviation and the direction of deviation that initiated and determined the direction of the righting reflex could be explained by possible otolithic activation.
Stimuli eliciting sexual arousal in males who offend adult women: an experimental study.
Kolárský, A; Madlafousek, J; Novotná, V
1978-03-01
The sexually arousing effects of short film scenes showing a naked actress's seductive behavior were phalloplethysmographically measured in 14 sexual deviates. These were males who had offended adult women, predominantly exhibitionists. Controls were 14 normal men. Deviates responded positively to the scenes and differentiated strong and weak seduction scenes similarly to normals. Consequently, the question arises of why deviates avoid their victim's erotic cooperation and why they do not offend their regular sexual partners. Post hoc analysis of five scenes which elicited a strikingly higher response in deviates than in normals suggested that these scenes contained reduced seductive behavior but unrestrained presentation of the genitals. This finding further encourages the laboratory study of stimulus conditions for abnormal sexual arousal which occurs during the sexual offense.
NASA Astrophysics Data System (ADS)
Wang, Jue
Understanding the influences of climate on productivity remains a major challenge in landscape ecology. Satellite remote sensing of normalized difference vegetation index (NDVI) provides a useful tool to study landscape patterns, based on generalization of local measurements, and to examine relations between climate and variation in productivity. This dissertation examines temporal and spatial relations between NDVI, productivity, and climatic factors over the course of nine years in the central Great Plains. Two general findings emerge: (1) integrated NDVI is a reliable measure of production, as validated with ground-based productivity measurements; and (2) precipitation is the primary factor that determines spatial and temporal patterns of NDVI. NDVI, integrated over appropriate time intervals, is strongly correlated with ground productivity measurements in forests, grasslands, and croplands. Most tree productivity measurements (tree ring size, tree diameter growth, and seed production) are strongly correlated with NDVI integrated for a period during the early growing season; foliage production is most strongly correlated with NDVI integrated over the entire growing season; and tree height growth corresponds with NDVI integrate during the previous growing season. Similarly, productivity measurements for herbaceous plants (grassland biomass and crop yield) are strongly correlated with NDVI. Within the growing season, the temporal pattern of grassland biomass production covaries with NDVI, with a four-week lag time. Across years, grassland biomass production covaries with NDVI integrated from part to all of the current growing season. Corn and wheat yield are most strongly related to NDVI integrated from late June to early August and from late April to mid-May, respectively. Precipitation strongly influences both temporal and spatial patterns of NDVI, while temperature influences NDVI only during the early and late growing season. In terms of temporal patterns, NDVI integrated over the growing season is strongly correlated with precipitation received during the current growing season plus the seven preceding months (fifteen month period); NDVI within the growing season responds to changes in precipitation with a four to eight week lag time; and major precipitation events lead to changes in NDVI with a two to four week lag time. Temperature has a positive correlation with NDVI during the early and late growing season, and a weak negative correlation during the middle of the growing season. In terms of spatial patterns, average precipitation is a strong predictor of the major east-west gradient of NDVI. Deviation from average precipitation explains most of the year-to-year variation in spatial patterns. NDVI and precipitation deviations from average covary (both positive or both negative) for 60--95% of the total land area in Kansas. Minimum and average temperatures are positively correlated with NDVI, but temperature deviation from average is generally not correlated with NDVI deviation from average. The strong relationships between NDVI and productivity, and between precipitation and NDVI, along with detailed analysis of the temporal and spatial patterns for our study region, provides the basis for prediction of productivity at landscape scales under different climate regimes.
Interhemispheric Asymmetry of the Sunward Plasma Flows for Strongly Dominant IMF BZ > 0
NASA Astrophysics Data System (ADS)
Yakymenko, K. N.; Koustov, A. V.; Fiori, R. A. D.
2018-01-01
Super Dual Auroral Radar Network (SuperDARN) convection maps obtained simultaneously in both hemispheres are averaged to infer polar cap ionospheric flow patterns under strongly dominant positive interplanetary magnetic field (IMF)
Testing General Relativity with Accretion-Flow Imaging of Sgr A^{*}.
Johannsen, Tim; Wang, Carlos; Broderick, Avery E; Doeleman, Sheperd S; Fish, Vincent L; Loeb, Abraham; Psaltis, Dimitrios
2016-08-26
The Event Horizon Telescope is a global, very long baseline interferometer capable of probing potential deviations from the Kerr metric, which is believed to provide the unique description of astrophysical black holes. Here, we report an updated constraint on the quadrupolar deviation of Sagittarius A^{*} within the context of a radiatively inefficient accretion flow model in a quasi-Kerr background. We also simulate near-future constraints obtainable by the forthcoming eight-station array and show that in this model already a one-day observation can measure the spin magnitude to within 0.005, the inclination to within 0.09°, the position angle to within 0.04°, and the quadrupolar deviation to within 0.005 at 3σ confidence. Thus, we are entering an era of high-precision strong gravity measurements.
Gordon, J. J.; Gardner, J. K.; Wang, S.; Siebers, J. V.
2012-01-01
Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of ≥5% in ∼1 mm2 areas and ≥2% in ∼20 mm2 areas. Conclusions: The ability to detect small dose differences (≤2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified. PMID:22894421
Quantification of processing artifacts in textile composites
NASA Technical Reports Server (NTRS)
Pastore, Christopher M.
1993-01-01
One of the greatest difficulties in developing detailed models of the mechanical response of textile reinforced composites is an accurate model of the reinforcing elements. In the case of elastic property prediction, the variation of fiber position may not have a critical role in performance. However, when considering highly localized stress events, such as those associated with cracks and holes, the exact position of the reinforcement probably dominates the failure mode. Models were developed for idealized reinforcements which provide an insight into the local behavior. However, even casual observations of micrographical images reveals that the actual material deviates strongly from the idealized models. Some of the deviations and causes are presented for triaxially braided and three dimensionally woven textile composites. The necessary modeling steps to accommodate these variations are presented with some examples. Some of the ramifications of not accounting for these discrepencies are also addressed.
Dynamic equilibrium under vibrations of H2 liquid-vapor interface at various gravity levels
NASA Astrophysics Data System (ADS)
Gandikota, G.; Chatain, D.; Lyubimova, T.; Beysens, D.
2014-06-01
Horizontal vibration applied to the support of a simple pendulum can deviate from the equilibrium position of the pendulum to a nonvertical position. A similar phenomenon is expected when a liquid-vapor interface is subjected to strong horizontal vibration. Beyond a threshold value of vibrational velocity the interface should attain an equilibrium position at an angle to the initial horizontal position. In the present paper experimental investigation of this phenomenon is carried out in a magnetic levitation device to study the effect of the vibration parameters, gravity acceleration, and the liquid-vapor density on the interface position. The results compare well with the theoretical expression derived by Wolf [G. H. Wolf, Z. Phys. B 227, 291 (1969), 10.1007/BF01397662].
Oostingh, Elsje C; Steegers-Theunissen, Régine P M; de Vries, Jeanne H M; Laven, Joop S E; Koster, Maria P H
2017-04-01
To study associations between periconceptional dietary patterns and semen quality parameters. Prospective periconception cohort study. Tertiary hospital. One hundred and twenty-nine male partners of pregnant women who participated in the Rotterdam Periconception Cohort (Predict study). None. Semen quality parameters-ejaculate volume, sperm concentration, total sperm count, progressive motility, immotile sperm, and total motile sperm count (TMSC). Men included in our study were on average 35 (±6 standard deviation) years old and had a body mass index of 26.4 ± 4 kg/m 2 . Two dietary patterns were identified using principle component analysis, which were labeled as "healthy" and "unhealthy." An increase of one factor score (stated as β) represented an increase of 1 standard deviation. Sperm concentration (β = 0.278; 95% CI, 0.112-0.444), total sperm count (β = 1.369; 95% CI, 0.244-2.495), progressive motility (β = 4.305; 95% CI, 0.675-7.936), and TMSC (β = 0.319; 95% CI, 0.113-0.526) were all positively associated with a strong adherence to the healthy dietary pattern. Subgroup analysis showed that these associations were mainly present in men with a TMSC <10 million spermatozoa. Although there was a trend toward a diminution in semen quality, we found no statistically significant associations with strong adherence to the unhealthy dietary pattern. The positive associations between strong adherence to a healthy dietary pattern and semen parameters in men with poor semen quality support the importance of preconceptional tailored nutritional counseling and coaching of couples who are trying to conceive. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Kim, Kyung-Seon; Park, Soo-Byung; Kim, Seong-Sik; Kim, Yong-Il
2013-01-01
Objective In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance. PMID:24015386
Schulze, Walther H. W.; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold. PMID:26587538
Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.
Ionospheric reflection of the magnetic activity described by the index η
NASA Astrophysics Data System (ADS)
Dziak-Jankowska, Beata; Stanisławska, Iwona; Ernst, Tomasz; Tomasik, Łukasz
2011-09-01
Differences in the external part of the vertical geomagnetic component point to the existence of local inhomogeneities in the magnetosphere or the ionosphere. Usually used magnetic indices are not sufficient to express the state of ionosphere, the common used global Kp index derived in the three-hour interval does not indicate much more rapidly changes appearing in ionosphere. Magnetic index η reflects ionospheric disturbances when other indices show very quiet conditions. Data of ionospheric characteristics (foE, foEs, h'E, h'F2) during 28-day long quiet day conditions (Kp = 0-2) in 2004 were analyzed. The correlations between strong local disturbances in ionosphere during very quiet days and high values of magnetic index η were found. The most sensitive to magnetic influence - ionospheric E layer data (foE characteristic) - reaches median deviations up to (+0.8 MHz and -0.8 MHz) during very low magnetic activity (Kp = 0-1). The high peaks (2-2.7) of the magnetic index η correlate in time with large local median deviations of foE. Such local deviations can suggest local inhomogeneities (vertical drifts) in the ionosphere. The correlation in space is not trivial. The strong peak of η is situated between the positive and negative deviations of foE. Additional observation is connected with correlation in time of the high η value with the negative median deviations of h'F2 (in some cases up to -90 km). The analysis was based on one-minute data recorded at each of 20 European Magnetic Observatories working in the INTERMAGNET network and from 19 ionosondes for 2004. Ionospheric data are sparse in time and in space in opposite to the magnetic data. The map of the magnetic indices can suggest the behavior of ionospheric characteristics in the areas where we have no data.
NASA Astrophysics Data System (ADS)
Wang, Hui; Wang, Mengyu; Baniasadi, Neda; Jin, Qingying; Elze, Tobias
2017-02-01
Purpose: To assess whether modeling of central vision loss (CVL) due to glaucoma by optical coherence tomography (OCT) retinal nerve fiber (RNF) layer thickness (RNFLT) can be improved by including the location of the major inferior temporal retinal artery (ITA), a known correlate of individual RNF geometry. Methods: Pat- tern deviations of the two locations of the Humphrey 24-2 visual field (VF) known to be specifically vulnerable to glaucomatous CVL and OCT RNFLT on the corresponding circumpapillary sector around the optic nerve head within the radius of 1.73mm were retrospectively selected from 428 eyes of 428 patients of a large clinical glaucoma service. ITA was marked on the 1.73mm circle by a trained observer. Linear regression models were fitted with CVL as dependent variable and VF mean deviation (MD) plus either of (1) RNFLT, (2) ITA, and (3) their combination, respectively, as regressors. To assess CVL over all levels of glaucoma severity, the three models were compared to a null model containing only MD. A Baysian model comparison was performed with the Bayes Factor (BF) as measure of strength of evidence (BF<3: no evidence, 3-20: positive evidence, >20: strong evidence over null model). Results: Neither RNFLT (BF=0.9) nor ITA (BF=1.4) alone provided positive evidence over the null model, but their combination resulted in a model with strong evidence (BF=21.4). Conclusion: While the established circumpapillary RNFLT sector, based on population statistics, could not satisfactorily model CVL, the inclusion of a retinal parameter related to individual eye anatomy yielded a strong structure-function model.
A micro-CMM with metrology frame for low uncertainty measurements
NASA Astrophysics Data System (ADS)
Brand, Uwe; Kirchhoff, Juergen
2005-12-01
A conventional bridge-type coordinate measuring machine (CMM) with an opto-tactile fibre probe for the measurement of microstructures has been equipped with a metrology frame in order to reduce its measurement uncertainty. The frame contains six laser interferometers for high-precision position and guiding deviation measurements, a Zerodur cuboid with three measuring surfaces for the laser interferometers to which the fibre probe is fixed, and an invar frame which supports the measuring objects and to which the reference mirrors of the interferometers are fixed. The orthogonality and flatness deviations of the Zerodur measuring surfaces have been measured and taken into account in the equation of motion of the probing sphere. As a first performance test, the flatness of an optical flat has been measured with the fibre probe. Measuring-depth-dependent and probing-force-dependent shifts of the probing position were observed. In order to reduce the scattering of the probing points, 77 measurements were averaged for one coordinate point to be measured. This has led to measuring times of several hours for one plane and strong thermal drifts of the measured probing points.
González-Hernández, J A; Pita-Alcorta, C; Padrón, A; Finalé, A; Galán, L; Martínez, E; Díaz-Comas, L; Samper-González, J A; Lencer, R; Marot, M
2014-10-01
Basic visual dysfunctions are commonly reported in schizophrenia; however their value as diagnostic tools remains uncertain. This study reports a novel electrophysiological approach using checkerboard visual evoked potentials (VEP). Sources of spectral resolution VEP-components C1, P1 and N1 were estimated by LORETA, and the band-effects (BSE) on these estimated sources were explored in each subject. BSEs were Z-transformed for each component and relationships with clinical variables were assessed. Clinical effects were evaluated by ROC-curves and predictive values. Forty-eight patients with schizophrenia (SZ) and 55 healthy controls participated in the study. For each of the 48 patients, the three VEP components were localized to both dorsal and ventral brain areas and also deviated from a normal distribution. P1 and N1 deviations were independent of treatment, illness chronicity or gender. Results from LORETA also suggest that deficits in thalamus, posterior cingulum, precuneus, superior parietal and medial occipitotemporal areas were associated with symptom severity. While positive symptoms were more strongly related to sensory processing deficits (P1), negative symptoms were more strongly related to perceptual processing dysfunction (N1). Clinical validation revealed positive and negative predictive values for correctly classifying SZ of 100% and 77%, respectively. Classification in an additional independent sample of 30 SZ corroborated these results. In summary, this novel approach revealed basic visual dysfunctions in all patients with schizophrenia, suggesting these visual dysfunctions represent a promising candidate as a biomarker for schizophrenia. Copyright © 2014 Elsevier B.V. All rights reserved.
Quasiparticle Energy in a Strongly Interacting Homogeneous Bose-Einstein Condensate.
Lopes, Raphael; Eigen, Christoph; Barker, Adam; Viebahn, Konrad G H; Robert-de-Saint-Vincent, Martin; Navon, Nir; Hadzibabic, Zoran; Smith, Robert P
2017-05-26
Using two-photon Bragg spectroscopy, we study the energy of particlelike excitations in a strongly interacting homogeneous Bose-Einstein condensate, and observe dramatic deviations from Bogoliubov theory. In particular, at large scattering length a the shift of the excitation resonance from the free-particle energy changes sign from positive to negative. For an excitation with wave number q, this sign change occurs at a≈4/(πq), in agreement with the Feynman energy relation and the static structure factor expressed in terms of the two-body contact. For a≳3/q we also see a breakdown of this theory, and better agreement with calculations based on the Wilson operator product expansion. Neither theory explains our observations across all interaction regimes, inviting further theoretical efforts.
Arday, D R; Brundage, J F; Gardner, L I; Goldenbaum, M; Wann, F; Wright, S
1991-06-15
The authors conducted a population-based study to attempt to estimate the effect of human immunodeficiency virus type 1 (HIV-1) seropositivity on Armed Services Vocational Aptitude Battery test scores in otherwise healthy individuals with early HIV-1 infection. The Armed Services Vocational Aptitude Battery is a 10-test written multiple aptitude battery administered to all civilian applicants for military enlistment prior to serologic screening for HIV-1 antibodies. A total of 975,489 induction testing records containing both Armed Services Vocational Aptitude Battery and HIV-1 results from October 1985 through March 1987 were examined. An analysis data set (n = 7,698) was constructed by choosing five controls for each of the 1,283 HIV-1-positive cases, matched on five-digit ZIP code, and a multiple linear regression analysis was performed to control for demographic and other factors that might influence test scores. Years of education was the strongest predictor of test scores, raising an applicant's score on a composite test nearly 0.16 standard deviation per year. The HIV-1-positive effect on the composite score was -0.09 standard deviation (99% confidence interval -0.17 to -0.02). Separate regressions on each component test within the battery showed HIV-1 effects between -0.39 and +0.06 standard deviation. The two Armed Services Vocational Aptitude Battery component tests felt a priori to be the most sensitive to HIV-1-positive status showed the least decrease with seropositivity. Much of the variability in test scores was not predicted by either HIV-1 serostatus or the demographic and other factors included in the model. There appeared to be little evidence of a strong HIV-1 effect.
Impact of buildings on surface solar radiation over urban Beijing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Bin; Liou, Kuo-Nan; Gu, Yu
The rugged surface of an urban area due to varying buildings can interact with solar beams and affect both the magnitude and spatiotemporal distribution of surface solar fluxes. Here we systematically examine the impact of buildings on downward surface solar fluxes over urban Beijing by using a 3-D radiation parameterization that accounts for 3-D building structures vs. the conventional plane-parallel scheme. We find that the resulting downward surface solar flux deviations between the 3-D and the plane-parallel schemes are generally ±1–10 W m -2 at 800 m grid resolution and within ±1 W m -2 at 4 km resolution. Pairsmore » of positive–negative flux deviations on different sides of buildings are resolved at 800 m resolution, while they offset each other at 4 km resolution. Flux deviations from the unobstructed horizontal surface at 4 km resolution are positive around noon but negative in the early morning and late afternoon. The corresponding deviations at 800 m resolution, in contrast, show diurnal variations that are strongly dependent on the location of the grids relative to the buildings. Both the magnitude and spatiotemporal variations of flux deviations are largely dominated by the direct flux. Furthermore, we find that flux deviations can potentially be an order of magnitude larger by using a finer grid resolution. Atmospheric aerosols can reduce the magnitude of downward surface solar flux deviations by 10–65 %, while the surface albedo generally has a rather moderate impact on flux deviations. The results imply that the effect of buildings on downward surface solar fluxes may not be critically significant in mesoscale atmospheric models with a grid resolution of 4 km or coarser. However, the effect can play a crucial role in meso-urban atmospheric models as well as microscale urban dispersion models with resolutions of 1 m to 1 km.« less
Burghelea, Manuela; Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry; Depuydt, Tom; Tournel, Koen; Hung, Cecilia; Simon, Viorica; Hiraoka, Masahiro; de Ridder, Mark
2015-07-15
The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°. Copyright © 2015 Elsevier Inc. All rights reserved.
Relationships between teleconnection patterns and Turkish climatic extremes
NASA Astrophysics Data System (ADS)
Baltacı, H.; Akkoyunlu, B. O.; Tayanç, M.
2017-12-01
This is a study on the effects of teleconnection patterns (TPs) on the extremes of temperature and precipitation over Turkey. Relationships between five teleconnection patterns, North Atlantic Oscillation (NAO), Arctic Oscillation (AO), East Atlantic-Western Russia (EAWR), East Atlantic (EA), and Scandinavian (SCA) patterns, and 11 climate extreme indices were studied by using 94 uniformly distributed meteorological stations over Turkey for the period of 1965-2014. Analyzing strong positive and negative temperature deviations from the 50-year-winter means shows that such extremes can often be explained by using AO and EAWR patterns. During the negative AO, generally more warm days occur over Black Sea (r = -0.6) and Aegean regions (r = -0.7). This phase of AO also generates above-normal precipitation in the western parts of the Anatolian Peninsula (r around - 0.5). Winter-time negative AO is mainly associated with the presence of a deepened Genoa cyclone over Italy that can transport warm and moist air mass from Mediterranean Sea towards Turkey by strong westerly winds. In contrast, positive EAWR is mainly connected to cold nights over Black Sea (r = 0.6) and Aegean regions (r = 0.6) together with positive precipitation anomalies at the seaside stations of the eastern Black Sea region. On the other hand, when positive EAWR prevails, Azores high-pressure center expands towards continental Europe bringing cold air by strong northerly winds together with higher moisture transport from the Black Sea. These results could pave the way for new possibilities regarding the projection of extremes in downscaling techniques.
Fesharaki, Maryam; Karagiannis, Peter; Tweed, Douglas; Sharpe, James A.; Wong, Agnes M. F.
2016-01-01
Purpose Skew deviation is a vertical strabismus caused by damage to the otolithic–ocular reflex pathway and is associated with abnormal ocular torsion. This study was conducted to determine whether patients with skew deviation show the normal pattern of three-dimensional eye control called Listing’s law, which specifies the eye’s torsional angle as a function of its horizontal and vertical position. Methods Ten patients with skew deviation caused by brain stem or cerebellar lesions and nine normal control subjects were studied. Patients with diplopia and neurologic symptoms less than 1 month in duration were designated as acute (n = 4) and those with longer duration were classified as chronic (n = 10). Serial recordings were made in the four patients with acute skew deviation. With the head immobile, subjects made saccades to a target that moved between straight ahead and eight eccentric positions, while wearing search coils. At each target position, fixation was maintained for 3 seconds before the next saccade. From the eye position data, the plane of best fit, referred to as Listing’s plane, was fitted. Violations of Listing’s law were quantified by computing the “thickness” of this plane, defined as the SD of the distances to the plane from the data points. Results Both the hypertropic and hypotropic eyes in patients with acute skew deviation violated Listing’s and Donders’ laws—that is, the eyes did not show one consistent angle of torsion in any given gaze direction, but rather an abnormally wide range of torsional angles. In contrast, each eye in patients with chronic skew deviation obeyed the laws. However, in chronic skew deviation, Listing’s planes in both eyes had abnormal orientations. Conclusions Patients with acute skew deviation violated Listing’s law, whereas those with chronic skew deviation obeyed it, indicating that despite brain lesions, neural adaptation can restore Listing’s law so that the neural linkage between horizontal, vertical, and torsional eye position remains intact. Violation of Listing’s and Donders’ laws during fixation arises primarily from torsional drifts, indicating that patients with acute skew deviation have unstable torsional gaze holding that is independent of their horizontal–vertical eye positions. PMID:18172094
Wootton, J Timothy
1987-07-01
I examined age at first reproduction of 547 mammalian species to determine the influence of diet and habitat on the evolution of life-history traits. Body mass correlated positively with age at first reproduction, explaining 56% of the variance. Habitat and trophic groups deviated significantly from the allometric curve in a pattern generally consistent with predictions from r/K selection theory and its modifications. However, mammalian orders also deviated significantly from the allometric curve, and different habitat and diet groups contained different ratios of mammalian orders. When the effects of orders were removed, residual deviations did not differ among ecological groups. Adjusting for ecological differences did not eliminate the differences between orders. These results suggest that body mass (or some correlated factor) and phylogeny strongly constrain age at first reproduction. Ecological factors appear to have little effect on the evolution of age at first reproduction. Apparent differences in weight-specific ages at first reproduction within habitats and trophic groups may be the result of ecological selection of order composition in the present, rather than ecologically driven evolution of life history in the past. © 1987 The Society for the Study of Evolution.
Gaia DR1 Evidence of Disrupting the Perseus Arm
NASA Astrophysics Data System (ADS)
Baba, Junichi; Kawata, Daisuke; Matsunaga, Noriyuki; Grand, Robert J. J.; Hunt, Jason A. S.
2018-02-01
We have discovered a clear sign of the disruption phase of the Perseus arm in the Milky Way using Cepheid variables, taking advantage of the accurately measured distances of Cepheids and the proper motions from Gaia Data Release 1. Both the Galactocentric radial and rotation velocities of 77 Cepheids within 1.5 kpc of the Perseus arm are correlated with their distances from the locus of the Perseus arm, as the trailing side is rotating faster and moving inward compared to the leading side. We also found a negative vertex deviation for the Cepheids on the trailing side, ‑27.°6 ± 2.°4, in contrast to the positive vertex deviation in the solar neighborhood. This is, to our knowledge, the first direct evidence that the vertex deviation around the Perseus arm is affected by the spiral arm. We compared these observational trends with our N-body/hydrodynamics simulations based on a static density-wave spiral scenario and with those based on a transient dynamic spiral scenario. Although our comparisons are limited to qualitative trends, they strongly favor the conclusion that the Perseus arm is in the disruption phase of a transient arm.
Five-DOF innovative linear MagLev slider to account for pitch, tilt and load uncertainty
NASA Astrophysics Data System (ADS)
Kao, Yi-Ming; Tsai, Nan-Chyuan; Chiu, Hsin-Lin
2017-02-01
This paper is focused at position deviation regulation upon a slider by Fuzzy Sliding Mode Control (FSMC). Five Degrees Of Freedom (DOF) of position deviation are required to be regulated except for the direction (i.e., X-axis) in which the slider moves forward and backward. Totally 8 sets of Magnetic Actuators (MAs) and an Electro-Pneumatic Transducer (EPT) are employed to drive the slider carrying loads under the commands of FSMC. EPT is applied to adjust the pressure of compressed air to counterbalance the weight of slider itself. At first, the system dynamic model of slider, including load uncertainty and load position uncertainty, is established. Intensive computer simulations are undertaken to verify the validity of proposed control strategy. Finally, a prototype of realistic slider position deviation regulation system is successfully built up. According to the experiments by cooperation of pneumatic and magnetic control, the actual linear position deviations of slider can be regulated within ±8 μm and angular position deviations within ±1 mini-degrees. From the viewpoint of energy consumption, the applied currents to 8 sets of MAs are all below 1.2 A. To sum up, the closed-loop levitation system by cooperation of pneumatic and magnetic control is capable to account for load uncertainty and uncertainty of the standing position of load to be carried.
Laidlaw, Kaitlin E W; Zhu, Mona J H; Kingstone, Alan
2016-06-01
Successful target selection often occurs concurrently with distractor inhibition. A better understanding of the former thus requires a thorough study of the competition that arises between target and distractor representations. In the present study, we explore whether the presence of a distractor influences saccade processing via interfering with visual target and/or saccade goal representations. To do this, we asked participants to make either pro- or antisaccade eye movements to a target and measured the change in their saccade trajectory and landing position (collectively referred to as deviation) in response to distractors placed near or far from the saccade goal. The use of an antisaccade paradigm may help to distinguish between stimulus- and goal-related distractor interference, as unlike with prosaccades, these two features are dissociated in space when making a goal-directed antisaccade response away from a visual target stimulus. The present results demonstrate that for both pro- and antisaccades, distractors near the saccade goal elicited the strongest competition, as indicated by greater saccade trajectory deviation and landing position error. Though distractors far from the saccade goal elicited, on average, greater deviation away in antisaccades than in prosaccades, a time-course analysis revealed a significant effect of far-from-goal distractors in prosaccades as well. Considered together, the present findings support the view that goal-related representations most strongly influence the saccade metrics tested, though stimulus-related representations may play a smaller role in determining distractor-based interference effects on saccade execution under certain circumstances. Further, the results highlight the advantage of considering temporal changes in distractor-based interference.
Determinants of ocular deviation in esotropic subjects under general anesthesia.
Daien, Vincent; Turpin, Chloé; Lignereux, François; Belghobsi, Riadh; Le Meur, Guylene; Lebranchu, Pierre; Pechereau, Alain
2013-01-01
The authors attempted to identify the determinants of ocular deviation in a population of patients with esotropia under general anesthesia. Forty-one patients with esotropia were included. Horizontal ocular deviation was evaluated by the photographic Hirschberg test both in the awakened state and under general anesthesia before surgery. Changes in ocular deviation were measured and a multivariate analysis was used to assess its clinical determinants. The mean age (± standard deviation [SD]) of study subjects was 13 ± 11 years and 51% were females. The mean spherical equivalent refraction of the right eye was 2.44 ± 2.50 diopters (D), with no significant difference between eyes (P = .26). The mean ocular deviation changed significantly, from 33.5 ± 12.5 prism diopters (PD) at preoperative examination to 8.8 ± 11.4 PD under general anesthesia (P = .0001). The changes in ocular deviation positively correlated with the pre-operative ocular deviation (correlation coefficient r = 0.59, P = .0001) and negatively correlated with patient age (correlation coefficient r = -0.53, P = .0001). These two determinants remained significant after multivariate adjustment of the following variables: preoperative ocular deviation; age; gender; spherical equivalent refraction; and number of previous strabismus surgeries (model r(2) = 0.49, P = .0001). The ocular position under general anesthesia was reported as a key factor in the surgical treatment of subjects with esotropia; therefore, its clinical determinants were assessed. The authors observed that preoperative ocular deviation and patient age were the main factors that influenced the ocular position under general anesthesia. Copyright 2013, SLACK Incorporated.
Romano, Paul E
2006-01-01
The HR (prism diopters [PD] per mm of corneal light reflection test [CLRT] asymmetry for strabometry) varies in humans from 14 to 24 PD/mm, but is totally unpredictable. Photo(grammetric) HR calibration in (of) each case facilitates acceptable strabometry precision and accuracy. Take 3 flash photos of the patient with both the preferred eye and then the deviating eye fixating straight ahead and then again with the deviation eye fixing at (+/-5-10 PD) the strabismic angle on a metric rule (stick) one meter away from the camera lens (where 1 cm = 1 PD). On these 3 photos, make four precise measurements of the position of the CLR with reference to the limbus: In the deviating eye fixing straight ahead and fixating at the angle of deviation. Divide the mm difference in location into the change in the angle of fixation to determine the HR for this patient at this angle. Then determine the CLR position in both the deviating eye and the fixing eye in the straight ahead primary position picture. Apply the calculated calibrated HR to the asymmetry of the CLRs in primary position to determine the true strabismic deviation. This imaging method insures accurate Hirschberg CLRT strabometry in each case, determining the deviation in "free space", under conditions of normal binocular viewing, uncontaminated by the artifacts or inaccuracies of other conventional strabometric methods or devices. So performed, the Hirschberg CLRT is the gold standard of strabometry.
NASA Astrophysics Data System (ADS)
Anderson, David; Yunes, Nicolás
2017-09-01
Scalar-tensor theories of gravity modify general relativity by introducing a scalar field that couples nonminimally to the metric tensor, while satisfying the weak-equivalence principle. These theories are interesting because they have the potential to simultaneously suppress modifications to Einstein's theory on Solar System scales, while introducing large deviations in the strong field of neutron stars. Scalar-tensor theories can be classified through the choice of conformal factor, a scalar that regulates the coupling between matter and the metric in the Einstein frame. The class defined by a Gaussian conformal factor with a negative exponent has been studied the most because it leads to spontaneous scalarization (i.e. the sudden activation of the scalar field in neutron stars), which consequently leads to large deviations from general relativity in the strong field. This class, however, has recently been shown to be in conflict with Solar System observations when accounting for the cosmological evolution of the scalar field. We here study whether this remains the case when the exponent of the conformal factor is positive, as well as in another class of theories defined by a hyperbolic conformal factor. We find that in both of these scalar-tensor theories, Solar System tests are passed only in a very small subset of coupling parameter space, for a large set of initial conditions compatible with big bang nucleosynthesis. However, while we find that it is possible for neutron stars to scalarize, one must carefully select the coupling parameter to do so, and even then, the scalar charge is typically 2 orders of magnitude smaller than in the negative-exponent case. Our study suggests that future work on scalar-tensor gravity, for example in the context of tests of general relativity with gravitational waves from neutron star binaries, should be carried out within the positive coupling parameter class.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chin-Cheng, E-mail: chen.ccc@gmail.com; Chang, Chang; Mah, Dennis
Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to themore » beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.« less
Technical Note: Spot characteristic stability for proton pencil beam scanning.
Chen, Chin-Cheng; Chang, Chang; Moyers, Michael F; Gao, Mingcheng; Mah, Dennis
2016-02-01
The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0-226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.
Bubbles Are Departures from Equilibrium Housing Markets: Evidence from Singapore and Taiwan
Chou, Chung-I; Li, Sai-Ping; Tee, Shang You; Cheong, Siew Ann
2016-01-01
The housing prices in many Asian cities have grown rapidly since mid-2000s, leading to many reports of bubbles. However, such reports remain controversial as there is no widely accepted definition for a housing bubble. Previous studies have focused on indices, or assumed that home prices are lognomally distributed. Recently, Ohnishi et al. showed that the tail-end of the distribution of (Japan/Tokyo) becomes fatter during years where bubbles are suspected, but stop short of using this feature as a rigorous definition of a housing bubble. In this study, we look at housing transactions for Singapore (1995 to 2014) and Taiwan (2012 to 2014), and found strong evidence that the equilibrium home price distribution is a decaying exponential crossing over to a power law, after accounting for different housing types. We found positive deviations from the equilibrium distributions in Singapore condominiums and Zhu Zhai Da Lou in the Greater Taipei Area. These positive deviations are dragon kings, which thus provide us with an unambiguous and quantitative definition of housing bubbles. Also, the spatial-temporal dynamics show that bubble in Singapore is driven by price pulses in two investment districts. This finding provides a valuable insight for policymakers on implementation and evaluation of cooling measures. PMID:27812187
Bubbles Are Departures from Equilibrium Housing Markets: Evidence from Singapore and Taiwan.
Tay, Darrell Jiajie; Chou, Chung-I; Li, Sai-Ping; Tee, Shang You; Cheong, Siew Ann
2016-01-01
The housing prices in many Asian cities have grown rapidly since mid-2000s, leading to many reports of bubbles. However, such reports remain controversial as there is no widely accepted definition for a housing bubble. Previous studies have focused on indices, or assumed that home prices are lognomally distributed. Recently, Ohnishi et al. showed that the tail-end of the distribution of (Japan/Tokyo) becomes fatter during years where bubbles are suspected, but stop short of using this feature as a rigorous definition of a housing bubble. In this study, we look at housing transactions for Singapore (1995 to 2014) and Taiwan (2012 to 2014), and found strong evidence that the equilibrium home price distribution is a decaying exponential crossing over to a power law, after accounting for different housing types. We found positive deviations from the equilibrium distributions in Singapore condominiums and Zhu Zhai Da Lou in the Greater Taipei Area. These positive deviations are dragon kings, which thus provide us with an unambiguous and quantitative definition of housing bubbles. Also, the spatial-temporal dynamics show that bubble in Singapore is driven by price pulses in two investment districts. This finding provides a valuable insight for policymakers on implementation and evaluation of cooling measures.
78 FR 26248 - Drawbridge Operation Regulation; York River, between Yorktown and Gloucester Point, VA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
... temporary deviation from the operating schedule that governs the draw of the US 17/George P. Coleman... deviation is necessary to facilitate electrical work on the George P. Coleman Memorial Swing Bridge. This deviation allows the drawbridge to remain in the closed to navigation position during the deviation period...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keeling, V; Jin, H; Ali, I
2014-06-01
Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin,more » Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.« less
Quantitative Postural Analysis of Children With Congenital Visual Impairment.
de Pádua, Michelle; Sauer, Juliana F; João, Silvia M A
2018-01-01
The aim of this study was to compare the postural alignment of children with visual impairment with that of children without visual impairment. The sample studied was 74 children of both sexes ages 5 to 12 years. Of these, 34 had visual impairment and 40 were control children. Digital photos from the standing position were used to analyze posture. Postural variables, such as tilt of the head, shoulder position, scapula position, lateral deviation of the spine, ankle position in the frontal plane and head posture, angle of thoracic kyphosis, angle of lumbar lordosis, pelvis position, and knee position in the frontal and sagittal planes, were measured with the Postural Assessment Software 0.63, version 36 (SAPO, São Paulo, Brazil), with markers placed in predetermined bony landmarks. The main results of this study showed that children with visual impairment have increased head tilt (P < .001), shoulder deviation in frontal plane (P = .004), lateral deviation of the spine (P < .001), changes in scapula position (P = .012), higher thoracic kyphosis (P = .004), and lower lumbar lordosis (P < .001). Visual impairment influences postural alignment. Children with visual impairment had increased head tilt, uneven shoulders, greater lateral deviation of the spine, thoracic kyphosis, lower lumbar lordosis, and more severe valgus deformities on knees. Copyright © 2017. Published by Elsevier Inc.
Kery, M.; Matthies, D.; Schmid, B.
2003-01-01
We studied ecological consequences of distyly for the declining perennial plant Primula veris in the Swiss Jura. Distyly favours cross-fertilization and avoids inbreeding, but may lead to pollen limitation and reduced reproduction if morph frequencies deviate from 50 %. Disassortative mating is promoted by the reciprocal position of stigmas and anthers in the two morphs (pin and thrum) and by intramorph incompatibility and should result in equal frequencies of morphs at equilibrium. However, deviations could arise because of demographic stochasticity, the lower intra-morph incompatibility of the pin morph, and niche differentiation between morphs. Demographic stochasticity should result in symmetric deviations from an even morph frequency among populations and in increased deviations with decreasing population size. If crosses between pins occurred, these would only generate pins, and this could result in a pin-bias of morph frequencies in general and in small populations in particular. If the morphs have different niches, morph frequencies should be related to environmental factors, morphs might be spatially segregated, and morphological differences between morphs would be expected. We tested these hypotheses in the declining distylous P. veris. We studied morph frequencies in relation to environmental conditions and population size, spatial segregation in field populations, morphological differences between morphs, and growth responses to nutrient addition. Morph frequencies in 76 populations with 1 - 80000 flowering plants fluctuated symmetrically about 50 %. Deviations from 50 % were much larger in small populations, and sixof the smallest populations had lost one morph altogether. In contrast, morph frequencies were neither related to population size nor to 17 measures of environmental conditions. We found no spatial segregation or morphological differences in the field or in the common garden. The results suggest that demographic stochasticity caused deviations of the morph ratiofrom unity in small populations. Demographic stochasticity was probably caused by the random elimination of plants during the fragmentation of formerly large continuous populations. Biased morph frequencies may be one of the reasons for the strongly reduced reproduction in small populations of P. veris.
Postural Stability is Altered by Blood Shift
NASA Astrophysics Data System (ADS)
Marais, M.; Denise, P.; Guincetre, J. Y.; Normand, H.
2008-06-01
Non-vestibular influences as shift in blood volume changed perception of body posture. Then, factors affecting blood shift may alter postural control. The purpose of our study was to investigate the effects of leg venous contention on postural stability. Twelve subjects were studied on a balance plate for 5 minutes with the eyes closed, in 3 conditions: with no leg venous contention or grade 1 and 3 support stockings. Standard deviation of x and y position was calculated before and after the closure of the eyes. Strong venous contention altered postural stability, after the eyes were closed, during the first 10 s of standing. As support stockings prevent blood shift induced by upright posture, this result is in line with the hypothesis that blood shifts influence the perception of body orientation and postural control among others factors as vision, vestibular inputs... This strong venous contention could induce an increase of fall.
Development and Deployment of NASA's Budget Execution Dashboard
NASA Technical Reports Server (NTRS)
Putz, Peter
2009-01-01
This paper discusses the successful implementation of a highly visible company-wide management system and its potential to change managerial and accounting policies, processes and practices in support of organizational goals. Applying the conceptual framework of innovation in organizations, this paper describes the development and deployment process of the NASA Budget Execution Dashboard and the first two fiscal years of its use. It discusses the positive organizational changes triggered by the dashboard, like higher visibility of financial goals and variances between plans and actuals, increased involvement of all management levels in tracking and correcting of plan deviations, establishing comparable data standards across a strongly diversified organization, and enhanced communication between line organizations (NASA Centers) and product organizations (Mission Directorates). The paper also discusses the critical success factors experienced in this project: Strong leadership and division of management roles, rapid and responsive technology development, and frequent communication among stakeholders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, S; Jacob, R; Popple, R
2016-06-15
Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, andmore » last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.« less
Numerical Large Deviation Analysis of the Eigenstate Thermalization Hypothesis
NASA Astrophysics Data System (ADS)
Yoshizawa, Toru; Iyoda, Eiki; Sagawa, Takahiro
2018-05-01
A plausible mechanism of thermalization in isolated quantum systems is based on the strong version of the eigenstate thermalization hypothesis (ETH), which states that all the energy eigenstates in the microcanonical energy shell have thermal properties. We numerically investigate the ETH by focusing on the large deviation property, which directly evaluates the ratio of athermal energy eigenstates in the energy shell. As a consequence, we have systematically confirmed that the strong ETH is indeed true even for near-integrable systems. Furthermore, we found that the finite-size scaling of the ratio of athermal eigenstates is a double exponential for nonintegrable systems. Our result illuminates the universal behavior of quantum chaos, and suggests that a large deviation analysis would serve as a powerful method to investigate thermalization in the presence of the large finite-size effect.
Misperceptions in the Trajectories of Objects undergoing Curvilinear Motion
Yilmaz, Ozgur; Tripathy, Srimant P.; Ogmen, Haluk
2012-01-01
Trajectory perception is crucial in scene understanding and action. A variety of trajectory misperceptions have been reported in the literature. In this study, we quantify earlier observations that reported distortions in the perceived shape of bilinear trajectories and in the perceived positions of their deviation. Our results show that bilinear trajectories with deviation angles smaller than 90 deg are perceived smoothed while those with deviation angles larger than 90 degrees are perceived sharpened. The sharpening effect is weaker in magnitude than the smoothing effect. We also found a correlation between the distortion of perceived trajectories and the perceived shift of their deviation point. Finally, using a dual-task paradigm, we found that reducing attentional resources allocated to the moving target causes an increase in the perceived shift of the deviation point of the trajectory. We interpret these results in the context of interactions between motion and position systems. PMID:22615775
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
77 FR 58491 - Drawbridge Operation Regulation; Willamette River, Portland, OR
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... deviation is necessary to accommodate the running of the Portland Marathon. This deviation allows the bridge to remain in the down or closed position during the marathon. DATES: This deviation is effective from... vessel traffic to facilitate safe, uninterrupted roadway passage of participants of the Portland Marathon...
Spontaneous Scalarization: Dead or Alive?
NASA Astrophysics Data System (ADS)
Berti, Emanuele; Crispino, Luis; Gerosa, Davide; Gualtieri, Leonardo; Horbatsch, Michael; Macedo, Caio; Okada da Silva, Hector; Pani, Paolo; Sotani, Hajime; Sperhake, Ulrich
2015-04-01
In 1993, Damour and Esposito-Farese showed that a wide class of scalar-tensor theories can pass weak-field gravitational tests and exhibit nonperturbative strong-field deviations away from General Relativity in systems involving neutron stars. These deviations are possible in the presence of ``spontaneous scalarization,'' a phase transition similar in nature to spontaneous magnetization in ferromagnets. More than twenty years after the original proposal, binary pulsar experiments have severely constrained the possibility of spontaneous scalarization occurring in nature. I will show that these experimental constraints have important implications for the torsional oscillation frequencies of neutron stars and for the so-called ``I-Love-Q'' relations in scalar-tensor theories. I will also argue that there is still hope to observe strong scalarization effects, despite the strong experimental bounds on the original mechanism. In particular, I will discuss two mechanisms that could produce strong scalarization in neutron stars: anisotropy and multiscalarization. This work was supported by NSF CAREER Award PHY-1055103.
PARALLAX AND ORBITAL EFFECTS IN ASTROMETRIC MICROLENSING WITH BINARY SOURCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nucita, A. A.; Paolis, F. De; Ingrosso, G.
2016-06-01
In gravitational microlensing, binary systems may act as lenses or sources. Identifying lens binarity is generally easy, in particular in events characterized by caustic crossing since the resulting light curve exhibits strong deviations from a smooth single-lensing light curve. In contrast, light curves with minor deviations from a Paczyński behavior do not allow one to identify the source binarity. A consequence of gravitational microlensing is the shift of the position of the multiple image centroid with respect to the source star location — the so-called astrometric microlensing signal. When the astrometric signal is considered, the presence of a binary sourcemore » manifests with a path that largely differs from that expected for single source events. Here, we investigate the astrometric signatures of binary sources taking into account their orbital motion and the parallax effect due to the Earth’s motion, which turn out not to be negligible in most cases. We also show that considering the above-mentioned effects is important in the analysis of astrometric data in order to correctly estimate the lens-event parameters.« less
Measurement of machine parts dimensions positional deviation with regard to their geometric accuracy
NASA Astrophysics Data System (ADS)
Martemyanov, D. B.; Pshenichnikova, V. V.; Penner, V. A.; Zemtsov, A. E.
2018-04-01
Real surfaces of the parts, obtained with the help of technological processes, are always characterized by deviations from a nominal (regular) form. When analyzing a nominal cylindrical surface or a prismatic component element, the interrelation between current dimensions in various sections and a surface form, as well as surfaces position, can be found.
Benign positional vertigo and hyperuricaemia.
Adam, A M
2005-07-01
To find out if there is any association between serum uric acid level and positional vertigo. A prospective, case controlled study. A private neurological clinic. All patients presenting with vertigo. Ninety patients were seen in this period with 78 males and 19 females. Mean age was 47 +/- 3 years (at 95% confidence level) with a standard deviation of 12.4. Their mean uric acid level was 442 +/- 16 (at 95% confidence level) with a standard deviation of 79.6 umol/l as compared to 291 +/- 17 (at 95% confidence level) with a standard deviation of 79.7 umol/l in the control group. The P-value was less than 0.001. That there is a significant association between high uric acid and benign positional vertigo.
NASA Astrophysics Data System (ADS)
Purohit, Suresh; Suthar, Shyam Sunder; Vyas, Mahendra; Beniwal, Ram Chandra
2018-05-01
The main transport properties of liquid or liquid mixtures are viscosity, diffusion, transference and electrical conductance. Viscosities of various liquid mixtures have been studied and their analyses have also been done by the help of some parameters. For each solution, the excess thermodynamic properties (YE) have been investigated. These excess thermodynamic properties are excess molar volume (VE), viscosity deviation (Δη) and excess Gibbs free energy of activation of viscous flow (ΔG*E). These parameters provide us the important information about interaction between molecules. For example, the negative value of VE and positive value of Δη shows the strong interaction between the solute and solvent molecules while positive value of VE and negative value of Δη shows the weak interaction between solute and solvent molecules. Above parameters and their discussion have been made in our earlier paper. In the present research paper, the viscosity data have been correlated with the equations of Grunberg and Nissan, Hind et al., Tamura and Kurata Katti. The excess values have been correlated using Redlich-Kister polynomial equation to obtain their coefficients and standard deviations. It has been found that in all cases, the data obtained fitted with the values correlated by the corresponding models very well. The results are interpreted in terms of molecular interactions occurring in the solution.
Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon
2016-11-01
Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.
Significant evidence for linkage disequilibrium over a 5-cM region among Afrikaners.
Gordon, D; Simonic, I; Ott, J
2000-05-15
We explore the extent of deviations from Hardy-Weinberg equilibrium (HWE) at a marker locus and linkage disequilibrium (LD) between pairs of marker loci in the Afrikaner population of South Africa. DNA samples were used for genotyping of 23 loci on six chromosomes. The samples were collected from 91 healthy unrelated Afrikaner adults. Exact tests were used to determine evidence for deviations from HWE at a single marker locus or LD between pairs of marker loci. At the 0.05 level of significance, evidence was found for deviation from HWE at only one of the 23 loci. At the same level of significance, LD was found among 8 of the 34 intrachromosomal pairs of loci. On chromosome 21, there was evidence for LD (P = 0.02) between a pair of loci with a genetic distance of 5.51 cM. On chromosome 2, there was evidence for LD between a pair of loci with a genetic distance of 5.28 cM (P = 0.002) and a pair of loci with a genetic distance of 3.68 cM (P = 0.0004). Detailed analysis of LD for one locus pair indicated that only a few of all alleles participated in the LD and that strong LD was most often positive. Our findings indicate that Afrikaans-speaking Afrikaners represent one of those special populations deemed particularly suitable for disequilibrium mapping. Copyright 2000 Academic Press.
Using walker during walking: a pilot study for health elder.
Po-Chan, Yeh; Cherng-Yee, Leung
2012-01-01
Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.
Use of a Binocular Optical Coherence Tomography System to Evaluate Strabismus in Primary Position.
Chopra, Reena; Mulholland, Pádraig J; Tailor, Vijay K; Anderson, Roger S; Keane, Pearse A
2018-05-31
Current clinical methods for assessing strabismus can be prone to error. Binocular optical coherence tomography (OCT) has the potential to assess and quantify strabismus objectively and in an automated manner. To evaluate the use of a binocular OCT prototype to assess the presence and size of strabismus. Fifteen participants with strabismus were recruited in 2016 as part of the EASE study from Moorfields Eye Hospital National Health Service Foundation Trust, London, England, and 15 healthy volunteers underwent automated anterior segment imaging using the binocular OCT prototype. All participants had an orthoptic assessment, including alternating prism cover test (APCT), before undergoing imaging. Simultaneously acquired pairs of OCT images, captured with 1 eye fixating, were analyzed using ImageJ (National Institutes of Health) to assess the presence and angle of strabismus. The direction and size of strabismus measured using binocular OCT was compared with that found using APCT. The median age for participants with strabismus was 55 years (interquartile range [IQR], 33-66.5 years) and for the healthy group, 50 years (IQR, 41-59 years); 15 participants (50%) were women, and 25 participants (83.3%) were white. The median magnitude of horizontal deviation was 20∆ (IQR, 13-35∆) and for vertical deviation, 3∆ (IQR, 0-5∆). Binocular OCT imaging correctly revealed the type and direction of the deviation in all 15 participants with strabismus, including horizontal and vertical deviations. The APCT and OCT measurements were strongly correlated for the horizontal (Pearson r = 0.85; 95% CI, 0.60-0.95; P < .001) and vertical (r = 0.89; 95% CI, 0.69-0.96; P < .001) deviations. In the healthy cohort, 9 of 15 participants (60%) had a latent horizontal deviation on APCT results (median magnitude 2∆, range 2-4∆). Six (40%) had orthophoria. Horizontal deviations were observed on OCT imaging results in 12 of the 15 participants (80%), and a vertical deviation was visible in 1 participant (6.7%). These findings suggest that binocular anterior segment OCT imaging can provide clinicians with a precise measurement of strabismus. The prototype can potentially incorporate several binocular vision tests that will provide quantitative data for the assessment, diagnosis, and monitoring of ocular misalignments.
Panichi, Roberto; Botti, Fabio Massimo; Ferraresi, Aldo; Faralli, Mario; Kyriakareli, Artemis; Schieppati, Marco; Pettorossi, Vito Enrico
2011-04-01
Self-motion perception and vestibulo-ocular reflex (VOR) were studied during whole body yaw rotation in the dark at different static head positions. Rotations consisted of four cycles of symmetric sinusoidal and asymmetric oscillations. Self-motion perception was evaluated by measuring the ability of subjects to manually track a static remembered target. VOR was recorded separately and the slow phase eye position (SPEP) was computed. Three different head static yaw deviations (active and passive) relative to the trunk (0°, 45° to right and 45° to left) were examined. Active head deviations had a significant effect during asymmetric oscillation: the movement perception was enhanced when the head was kept turned toward the side of body rotation and decreased in the opposite direction. Conversely, passive head deviations had no effect on movement perception. Further, vibration (100 Hz) of the neck muscles splenius capitis and sternocleidomastoideus remarkably influenced perceived rotation during asymmetric oscillation. On the other hand, SPEP of VOR was modulated by active head deviation, but was not influenced by neck muscle vibration. Through its effects on motion perception and reflex gain, head position improved gaze stability and enhanced self-motion perception in the direction of the head deviation. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ward, Thomas; Wey, Chi; Glidden, Robert; Hosoi, A. E.; Bertozzi, A. L.
2009-08-01
The flow of viscous, particle-laden wetting thin films on an inclined plane is studied experimentally as the particle concentration is increased to the maximum packing limit. The slurry is a non-neutrally buoyant mixture of silicone oil and either solid glass beads or glass bubbles. At low concentrations (ϕ <0.45), the elapsed time versus average front position scales with the exponent predicted by Huppert [Nature (London) 300, 427 (1982)]. At higher concentrations, the average front position still scales with the exponent predicted by Huppert on some time interval, but there are observable deviations due to internal motion of the particles. At the larger concentration values and at later times, the departure from Huppert is seen to strongly depend on total slurry volume VT, inclination angle α, density difference, and particle size range.
Parents behaving badly: Gender biases in the perception of parental alienating behaviors.
Harman, Jennifer J; Biringen, Zeynep; Ratajack, Ellen M; Outland, Pearl L; Kraus, Allyson
2016-10-01
According to gender role theory, individuals who confirm expectations associated with their gender roles are rewarded and judged against these expectations when they deviate. Parental roles are strongly tied to gender, and there are very different expectations for behaviors of mothers and fathers. This study examined how mothers' and fathers' behaviors that support or discourage a positive relationship with the other parent are perceived in terms of their acceptability. Two-hundred twenty-eight parents completed an online survey assessing perceptions of acceptability of negative (parental alienating) and positive coparenting behaviors. Results provided support for our hypothesis: Although parental alienating behaviors were rated unacceptable, they were more acceptable for mothers than fathers. Expectancy violation theory can explain why parental alienating behaviors are not viewed as negatively when mothers exhibit them than fathers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
VDLLA: A virtual daddy-long legs optimization
NASA Astrophysics Data System (ADS)
Yaakub, Abdul Razak; Ghathwan, Khalil I.
2016-08-01
Swarm intelligence is a strong optimization algorithm based on a biological behavior of insects or animals. The success of any optimization algorithm is depending on the balance between exploration and exploitation. In this paper, we present a new swarm intelligence algorithm, which is based on daddy long legs spider (VDLLA) as a new optimization algorithm with virtual behavior. In VDLLA, each agent (spider) has nine positions which represent the legs of spider and each position represent one solution. The proposed VDLLA is tested on four standard functions using average fitness, Medium fitness and standard deviation. The results of proposed VDLLA have been compared against Particle Swarm Optimization (PSO), Differential Evolution (DE) and Bat Inspired Algorithm (BA). Additionally, the T-Test has been conducted to show the significant deference between our proposed and other algorithms. VDLLA showed very promising results on benchmark test functions for unconstrained optimization problems and also significantly improved the original swarm algorithms.
Lunar Laser Ranging Science: Gravitational Physics and Lunar Interior and Geodesy
NASA Technical Reports Server (NTRS)
Williams, James G.; Turyshev, Slava G.; Boggs, Dale H.; Ratcliff, J. Todd
2004-01-01
Laser pulses fired at retroreflectors on the Moon provide very accurate ranges. Analysis yields information on Earth, Moon, and orbit. The highly accurate retroreflector positions have uncertainties less than a meter. Tides on the Moon show strong dissipation, with Q=33+/-4 at a month and a weak dependence on period. Lunar rotation depends on interior properties; a fluid core is indicated with radius approx.20% that of the Moon. Tests of relativistic gravity verify the equivalence principle to +/-1.4x10(exp -13), limit deviations from Einstein's general relativity, and show no rate for the gravitational constant G/G with uncertainty 9x10(exp -13)/yr.
Tye-Din, J A; Cameron, D J S; Daveson, A J; Day, A S; Dellsperger, P; Hogan, C; Newnham, E D; Shepherd, S J; Steele, R H; Wienholt, L; Varney, M D
2015-01-01
The past decade has seen human leukocyte antigen (HLA) typing emerge as a remarkably popular test for the diagnostic work-up of coeliac disease with high patient acceptance. Although limited in its positive predictive value for coeliac disease, the strong disease association with specific HLA genes imparts exceptional negative predictive value to HLA typing, enabling a negative result to exclude coeliac disease confidently. In response to mounting evidence that the clinical use and interpretation of HLA typing often deviates from best practice, this article outlines an evidence-based approach to guide clinically appropriate use of HLA typing, and establishes a reporting template for pathology providers to improve communication of results. PMID:25827511
NASA Astrophysics Data System (ADS)
Ohara, Masaki; Noguchi, Toshihiko
This paper describes a new method for a rotor position sensorless control of a surface permanent magnet synchronous motor based on a model reference adaptive system (MRAS). This method features the MRAS in a current control loop to estimate a rotor speed and position by using only current sensors. This method as well as almost all the conventional methods incorporates a mathematical model of the motor, which consists of parameters such as winding resistances, inductances, and an induced voltage constant. Hence, the important thing is to investigate how the deviation of these parameters affects the estimated rotor position. First, this paper proposes a structure of the sensorless control applied in the current control loop. Next, it proves the stability of the proposed method when motor parameters deviate from the nominal values, and derives the relationship between the estimated position and the deviation of the parameters in a steady state. Finally, some experimental results are presented to show performance and effectiveness of the proposed method.
Random errors in interferometry with the least-squares method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Qi
2011-01-20
This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hazelaar, Colien, E-mail: c.hazelaar@vumc.nl; Dahele, Max; Mostafavi, Hassan
Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shiftsmore » between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
... deviation the Loop Parkway and the Meadowbrook Parkway Bridges may remain in the closed position between 11... operation of the Loop Parkway Bridge, mile 0.7, across Long Creek, and the Meadowbrook Parkway Bridge, mile... remain in the closed position during this public event. DATES: This deviation is effective from 11 a.m...
Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio
2014-06-01
Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.
Characterization and Identification of Productivity-Associated Rhizobacteria in Wheat
Habiger, Joshua
2012-01-01
The rhizosphere is populated by a numerous and diverse array of rhizobacteria, and many impact productivity in largely unknown ways. Here we characterize the rhizobacterial community in a wheat variety categorized according to shoot biomass using 16S rRNA pyrosequencing abundance data. Plants were grown in homogenized field soil under greenhouse conditions, and DNA was extracted and pyrosequenced, resulting in 29,007 quality sequences. Operational taxonomic units (OTUs) that were significantly associated with biomass productivity were identified using an exact test adjusted for the false-discovery rate. The productivity deviation expressed as a percentage of the total mean square for regression (PMSR) was determined for each OTU. Out of 719 OTUs, 42 showed significant positive associations and 39 showed significant negative associations (q value, ≤0.05). OTUs with the greatest net positive associations, by genus, were as follows: Duganella, OTU 43 and OTU 3; Janthinobacterium, OTU 278; Pseudomonas, OTU 588; and Cellvibrio, OTU 1847. Those with negative associations were as follows: Bacteria, OTU 273; Chryseobacterium, OTU 508; Proteobacteria, OTU 249; and Enterobacter, OTU 357. Shoot biomass productivity was strongly correlated with the balance between the overall abundances of positive- and negative-productivity-associated OTUs. High-productivity rhizospheres contained 9.2 significant positives for every negatively associated rhizobacterium, while low-productivity rhizospheres showed 2.3 significant negatives for every positively associated rhizobacterium. Overall rhizobacterial community diversity as measured by the Chao1, Shannon, and Simpson indexes was nonlinearly related to productivity, closely fitting a wavelike cubic equation. We conclude that shoot biomass productivity is strongly related to the ratio of positive- to negative-productivity-associated rhizobacteria in the rhizosphere. This study identifies significant OTUs composing the productive and unproductive rhizobacterial communities. PMID:22504815
Lin, Yifan; Chen, Gui; Fu, Zhen; Ma, Lian; Li, Weiran
2015-01-01
To evaluate, using cone-beam computed tomography (CBCT), both the condylar-fossa relationships and the mandibular and condylar asymmetries between unilateral cleft lip and palate (UCLP) patients and non-cleft patients with class III skeletal relationship, and to investigate the factors of asymmetry contributing to chin deviation. The UCLP and non-cleft groups consisted of 30 and 40 subjects, respectively, in mixed dentition with class III skeletal relationships. Condylar-fossa relationships and the dimensional and positional asymmetries of the condyles and mandibles were examined using CBCT. Intra-group differences were compared between two sides in both groups using a paired t-test. Furthermore, correlations between each measurement and chin deviation were assessed. It was observed that 90% of UCLP and 67.5% of non-cleft subjects had both condyles centered, and no significant asymmetry was found. The axial angle and the condylar center distances to the midsagittal plane were significantly greater on the cleft side than on the non-cleft side (P=0.001 and P=0.028, respectively) and were positively correlated with chin deviation in the UCLP group. Except for a larger gonial angle on the cleft side, the two groups presented with consistent asymmetries showing shorter mandibular bodies and total mandibular lengths on the cleft (deviated) side. The average chin deviation was 1.63 mm to the cleft side, and the average absolute chin deviation was significantly greater in the UCLP group than in the non-cleft group (P=0.037). Compared with non-cleft subjects with similar class III skeletal relationships, the subjects with UCLP showed more severe lower facial asymmetry. The subjects with UCLP presented with more asymmetrical positions and rotations of the condyles on axial slices, which were positively correlated with chin deviation.
NASA Astrophysics Data System (ADS)
Shirmohamadi, Mohamad; Kadkhodaie, Ali; Rahimpour-Bonab, Hossain; Faraji, Mohammad Ali
2017-04-01
Velocity deviation log (VDL) is a synthetic log used to determine pore types in reservoir rocks based on a combination of the sonic log with neutron-density logs. The current study proposes a two step approach to create a map of porosity and pore types by integrating the results of petrographic studies, well logs and seismic data. In the first step, velocity deviation log was created from the combination of the sonic log with the neutron-density log. The results allowed identifying negative, zero and positive deviations based on the created synthetic velocity log. Negative velocity deviations (below - 500 m/s) indicate connected or interconnected pores and fractures, while positive deviations (above + 500 m/s) are related to isolated pores. Zero deviations in the range of [- 500 m/s, + 500 m/s] are in good agreement with intercrystalline and microporosities. The results of petrographic studies were used to validate the main pore type derived from velocity deviation log. In the next step, velocity deviation log was estimated from seismic data by using a probabilistic neural network model. For this purpose, the inverted acoustic impedance along with the amplitude based seismic attributes were formulated to VDL. The methodology is illustrated by performing a case study from the Hendijan oilfield, northwestern Persian Gulf. The results of this study show that integration of petrographic, well logs and seismic attributes is an instrumental way for understanding the spatial distribution of main reservoir pore types.
The Ghanaian Economic Recovery
2013-12-01
Adjustment Programs6 instituted by the IMF and World Bank, combined with currency devaluation and smaller government, are responsible for Ghana’s recent...study shows that every negative deviation year was preceded by protectionist policies, and, with one exception (explained by currency devaluation ...negative deviation year was preceded by protectionist policies, and, with one exception (explained by currency devaluation ), every positive deviation
77 FR 58773 - Drawbridge Operation Regulations; Pequonnock River, Bridgeport, CT, Maintenance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-24
... remain in the closed position to facilitate electrical repairs. DATES: This deviation is effective from... and repairs. The operator of the bridge, Metro North Railroad, requested a temporary deviation from...
Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J
2017-02-01
Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.
Mandibular deviations in TMD and non-TMD groups related to eye dominance and head posture.
Pradham, N S; White, G E; Mehta, N; Forgione, A
2001-01-01
This study was designed to determine whether eye-dominance affects head posture (rotation) and in turn, whether head posture is associated with mandibular frenum midline deviation, in both TMJ and control subjects. Eye dominance was determined using three tests: Porta, Hole, Point tests. Natural head posture was evaluated using the Arthrodial protractor. Mandibular frenum deviation was recorded as left, right or no deviation. Fifty female subjects were included in the study, 25 TMJ patients attending the Gelb Craniomandibular Pain Center and 25 non-TMJ control subjects. The findings indicate that eye dominance and direction of head rotation are strongly associated in both TMJ and control subjects. Further, in TMJ subjects mandibular deviation occurred in greater frequency than in controls and tends to occur in the contra lateral direction of head rotation.
Rago, Livia; Di Castelnuovo, Augusto; Assanelli, Deodato; Badilini, Fabio; Vaglio, Martino; Gianfagna, Francesco; Salvetti, Massimo; Zito, Francesco; Alessandrini, Francesco; Donati, Maria Benedetta; de Gaetano, Giovanni; Iacoviello, Licia
2013-02-01
We aimed at investigating the association between T-wave axis deviation, metabolic syndrome (MetS), its components and estimated risk of cardiovascular disease (CVD) at 10 years in an adult Italian population. 11,143 women (54 ± 11 years) and 9742 men (55 ± 11 years) were analyzed from the Moli-sani cohort, randomly recruited from the general population. MetS was defined using the ATPIII criteria. T-wave axis deviation was measured from the standard 12-lead resting electrocardiogram. CVD risk in ten years was estimated by the CUORE score. 29% of men and 27% of women with MetS showed borderline or abnormal T-wave as compared to 24% and 17% without MetS (p < 0.0001 for both genders). Among components of MetS, elevated waist and blood pressure were strongly associated with T-wave axis deviation, whereas glucose, HDL and triglycerides were only marginally. The odds of having borderline or abnormal T-wave axis deviation in multivariable regression analysis, was 1.38 (95% CI:1.25-1.53) in MetS men and 1.68 (95% CI:1.51-1.87) in MetS women compared to those without. Further adjustment for MetS components completely abolished the associations. Abnormal T-wave axis deviation was associated with an increased risk of CVD in 10 years in men (OR = 4.4; 95% CI:1.10-17.9). T-wave axis deviation is strongly associated with components of the MetS, in particular high waist circumference and blood pressure and with an increased CVD risk, particularly in men. ECG monitoring to identify T-wave axis deviation in obese, hypertensive or MetS subjects can be an early indicator of vascular disease and help in reducing cardiac events. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Afifah, M. R. Nurul; Aziz, A. Che; Roslan, M. Kamal
2015-09-01
Sediment samples were collected from the shallow marine from Kuala Besar, Kelantan outwards to the basin floor of South China Sea which consisted of quaternary bottom sediments. Sixty five samples were analysed for their grain size distribution and statistical relationships. Basic statistical analysis like mean, standard deviation, skewness and kurtosis were calculated and used to differentiate the depositional environment of the sediments and to derive the uniformity of depositional environment either from the beach or river environment. The sediments of all areas were varied in their sorting ranging from very well sorted to poorly sorted, strongly negative skewed to strongly positive skewed, and extremely leptokurtic to very platykurtic in nature. Bivariate plots between the grain-size parameters were then interpreted and the Coarsest-Median (CM) pattern showed the trend suggesting relationships between sediments influenced by three ongoing hydrodynamic factors namely turbidity current, littoral drift and waves dynamic, which functioned to control the sediments distribution pattern in various ways.
Geng, Wei; Liu, Changying; Su, Yucheng; Li, Jun; Zhou, Yanmin
2015-01-01
Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement. PMID:26309497
Social smile reproducibility using 3-D stereophotogrammetry and reverse engineering technology.
Dindaroğlu, Furkan; Duran, Gökhan Serhat; Görgülü, Serkan; Yetkiner, Enver
2016-05-01
To assess the range of social smile reproducibility using 3-D stereophotogrammetry and reverse engineering technology. Social smile images of white adolescents (N = 15, mean age = 15.4 ±1.5 years; range = 14-17 years) were obtained using 3dMDFlex (3dMD, Atlanta, Ga). Each participant was asked to produce 16 social smiles at 3-minute intervals. All images were obtained in natural head position. Alignment of images, segmentation of smile area, and 3-D deviation analysis were carried out using Geomagic Control software (3D Systems Inc, Cary, NC). A single image was taken as a reference, and the remaining 15 images were compared with the reference image to evaluate positive and negative deviations. The differences between the mean deviation limits of participants with the highest and the lowest deviations and the total mean deviations were evaluated using Bland-Altman Plots. Minimum and maximum deviations of a single image from the reference image were 0.34 and 2.69 mm, respectively. Lowest deviation between two images was within 0.5 mm and 1.54 mm among all participants (mean, 0.96 ± 0.21 mm), and the highest deviation was between 0.41 mm and 2.69 mm (mean, 1.53 ± 0.46 mm). For a single patient, when all alignments were considered together, the mean deviation was between 0.32 ± 0.10 mm and 0.59 ± 0.24 mm. Mean deviation for one image was between 0.14 and 1.21 mm. The range of reproducibility of the social smile presented individual variability, but this variation was not clinically significant or detectable under routine clinical observation.
Automating linear accelerator quality assurance.
Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M
2015-10-01
The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Duration of breast feeding and language ability in middle childhood.
Whitehouse, Andrew J O; Robinson, Monique; Li, Jianghong; Oddy, Wendy H
2011-01-01
There is controversy over whether increased breast-feeding duration has long-term benefits for language development. The current study examined whether the positive associations of breast feeding on language ability at age 5 years in the Western Australian Pregnancy (Raine) Cohort, were still present at age 10 years. The Raine Study is a longitudinal study of 2868 liveborn children recruited at approximately 18 weeks gestation. Breast-feeding data were based upon information prospectively collected during infancy, and were summarised according to four categories of breast-feeding duration: (1) never breast-fed, (2) breast-fed predominantly for <4 months, (3) breast-fed predominantly for 4-6 months, and (4) breast-fed predominantly for >6 months. Language ability was assessed in 1195 children at the 10 year follow-up (mean age = 10.58 years; standard deviation = 0.19) using the Peabody Picture Vocabulary Test - Revised (PPVT-R), which is based around a mean of 100 and a standard deviation of 15. Associations between breast-feeding duration and PPVT-R scores were assessed before and after adjustment for a range of sociodemographic, obstetric and psychosocial covariates. Analysis of variance revealed a strong positive association between the duration of predominant breast feeding and PPVT-R at age 10 years. A multivariable linear regression analysis adjusted for covariates and found that children who were predominantly breast-fed for >6 months had a mean PPVT-R score that was 4.04 points higher than children who were never breast-fed. This compared with an increase of 3.56 points at age 5 years. Breast feeding for longer periods in early life has a positive and statistically-independent effect on language development in middle childhood. © 2010 Blackwell Publishing Ltd.
NASA Technical Reports Server (NTRS)
Hones, E. W., Jr.; Bame, S. J.; Birn, J.; Paschmann, G.; Russell, C. T.
1982-01-01
The magnetic field in the plasmoid which is created by the reconnection of magnetic field lines at a neutral line formed in the near-earth region of the plasma sheet at substorm onset, and which flows out of the magnetotail into the magnetosphere's wake, displays a strong positive or negative Y(SM) component that has been difficult to reconcile with the standard, two-dimensional reconnection geometry. It is shown that this deviation of the magnetic field is a manifestation of the newly-reconnected field line loop's draping toward the tail's central or midnight meridian, and that the draping is a consequence of the three-dimensional plasma flow associated with the reconnection process.
Ethyl 2-[(carbamothioyl-amino)-imino]-propano-ate.
Corrêa, Charlane C; Graúdo, José Eugênio J C; de Oliveira, Luiz Fernando C; de Almeida, Mauro V; Diniz, Renata
2011-08-01
The title compound, C(6)H(11)N(3)O(2)S, consists of a roughly planar mol-ecule (r.m.s deviation from planarity = 0.077 Å for the non-H atoms) and has the S atom in an anti position to the imine N atom. This N atom is the acceptor of a strongly bent inter-nal N-H⋯N hydrogen bond donated by the amino group. In the crystal, mol-ecules are arranged in undulating layers parallel to (010). The mol-ecules are linked via inter-molecular amino-carboxyl N-H⋯O hydrogen bonds, forming chains parallel to [001]. The chains are cross-linked by N(carbazone)-H⋯S and C-H⋯S inter-actions, forming infinite sheets.
Radhika, R; Shankar, R; Vijayakumar, S; Kolandaivel, P
2018-05-01
The theoretical studies on DNA with the anticancer drug 6-Mercaptopurine (6-MP) are investigated using theoretical methods to shed light on drug designing. Among the DNA base pairs considered, 6-MP is stacked with GC with the highest interaction energy of -46.19 kcal/mol. Structural parameters revealed that structure of the DNA base pairs is deviated from the planarity of the equilibrium position due to the formation of hydrogen bonds and stacking interactions with 6-MP. These deviations are verified through the systematic comparison between X-H bond contraction and elongation and the associated blue shift and red shift values by both NBO analysis and vibrational analysis. Bent's rule is verified for the C-H bond contraction in the 6-MP interacted base pairs. The AIM results disclose that the higher values of electron density (ρ) and Laplacian of electron density (∇ 2 ρ) indicate the increased overlap between the orbitals that represent the strong interaction and positive values of the total electron density show the closed-shell interaction. The relative sensitivity of the chemical shift values for the DNA base pairs with 6-MP is investigated to confirm the hydrogen bond strength. Molecular dynamics simulation studies of G-quadruplex DNA d(TGGGGT) 4 with 6-MP revealed that the incorporation of 6-MP appears to cause local distortions and destabilize the G-quadruplex DNA.
Pettorossi, V E; Petrosini, L
1984-12-17
In intact guinea pigs a passive horizontal rotation of the body about the fixed head induces compensatory ocular movements (cervico-ocular reflex). When the static neck deviation is maintained, a significant ocular displacement is observed. In acutely hemilabyrinthectomized animals, static body deviation towards the lesion side tonically alters eye nystagmus. It affects slow phase eye velocity and quick phase amplitude and frequency causing the eye to reach a less eccentric orbital position. Apart from such immediate influences, a plastic effect on eye nystagmus abatement is induced. In the animals restrained with no body-on-head deviation, abatement of nystagmus is delayed with respect to the animals restrained with 35 degrees body deviation towards the lesion side. Thus the head position signal is not only a contributing factor for the correction of postural deficits but also influences the time course of the ocular balancing process following unilateral vestibular damage.
System and method for controlling a vision guided robot assembly
Lin, Yhu-Tin; Daro, Timothy; Abell, Jeffrey A.; Turner, III, Raymond D.; Casoli, Daniel J.
2017-03-07
A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.
Titanium Alloy Strong Back for IXO Mirror Segments
NASA Technical Reports Server (NTRS)
Byron, Glenn P.; Kai-Wang, Chan
2011-01-01
A titanium-alloy mirror-holding fixture called a strong back allows the temporary and permanent bonding of a 50 degree D263 glass x-ray mirror (IXO here stands for International X-ray Observatory). The strong back is used to hold and position a mirror segment so that mounting tabs may be bonded to the mirror with ultra-low distortion of the optical surface. Ti-15%Mo alloy was the material of choice for the strong back and tabs because the coefficient of thermal expansion closely matches that of the D263 glass and the material is relatively easy to machine. This invention has the ability to transfer bonded mounting points from a temporary location on the strong back to a permanent location on the strong back with minimal distortion. Secondly, it converts a single mirror segment into a rigid body with an acceptable amount of distortion of the mirror, and then maneuvers that rigid body into optical alignment such that the mirror segment can be bonded into a housing simulator or mirror module. Key problems are that the mirrors are 0.4-mm thick and have a very low coefficient of thermal expansion (CTE). Because the mirrors are so thin, they are very flexible and are easily distorted. When permanently bonding the mirror, the goal is to achieve a less than 1-micron distortion. Temperature deviations in the lab, which have been measured to be around 1 C, have caused significant distortions in the mirror segment.
[A new kinematics method of determing elbow rotation axis and evaluation of its feasibility].
Han, W; Song, J; Wang, G Z; Ding, H; Li, G S; Gong, M Q; Jiang, X Y; Wang, M Y
2016-04-18
To study a new positioning method of elbow external fixation rotation axis, and to evaluate its feasibility. Four normal adult volunteers and six Sawbone elbow models were brought into this experiment. The kinematic data of five elbow flexion were collected respectively by optical positioning system. The rotation axes of the elbow joints were fitted by the least square method. The kinematic data and fitting results were visually displayed. According to the fitting results, the average moving planes and rotation axes were calculated. Thus, the rotation axes of new kinematic methods were obtained. By using standard clinical methods, the entrance and exit points of rotation axes of six Sawbone elbow models were located under X-ray. And The kirschner wires were placed as the representatives of rotation axes using traditional positioning methods. Then, the entrance point deviation, the exit point deviation and the angle deviation of two kinds of located rotation axes were compared. As to the four volunteers, the indicators represented circular degree and coplanarity of elbow flexion movement trajectory of each volunteer were both about 1 mm. All the distance deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 3 mm. All the angle deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 5°. As to the six Sawbone models, the average entrance point deviations, the average exit point deviations and the average angle deviations of two different rotation axes determined by two kinds of located methods were respectively 1.697 2 mm, 1.838 3 mm and 1.321 7°. All the deviations were very small. They were all in an acceptable range of clinical practice. The values that represent circular degree and coplanarity of volunteer's elbow single curvature movement trajectory are very small. The result shows that the elbow single curvature movement can be regarded as the approximate fixed axis movement. The new method can replace the traditional method in accuracy. It can make up the deficiency of the traditional fixed axis method.
NASA Astrophysics Data System (ADS)
Kuruliuk, K. A.; Kulesh, V. P.
2016-10-01
An optical videogrammetry method using one digital camera for non-contact measurements of geometric shape parameters, position and motion of models and structural elements of aircraft in experimental aerodynamics was developed. The tests with the use of this method for measurement of six components (three linear and three angular ones) of real position of helicopter device in wind tunnel flow were conducted. The distance between camera and test object was 15 meters. It was shown in practice that, in the conditions of aerodynamic experiment instrumental measurement error (standard deviation) for angular and linear displacements of helicopter device does not exceed 0,02° and 0.3 mm, respectively. Analysis of the results shows that at the minimum rotor thrust deviations are systematic and generally are within ± 0.2 degrees. Deviations of angle values grow with the increase of rotor thrust.
Frank Wilczek, Asymptotic Freedom, and Strong Interaction
whereby quarks behave as free particles when they are close together, but become more strongly attracted , Issue 26; 1973 Asymptotically Free Gauge Theories I; DOE Technical Report; 1973 Scaling Deviations for Neutrino Reactions in Asymptotically Free Field Theories; DOE Technical Report; 1974 Weak-interaction
NASA Technical Reports Server (NTRS)
Rhoads, James E.; Rigby, Jane Rebecca; Malhotra, Sangeeta; Allam, Sahar; Carilli, Chris; Combes, Francoise; Finkelstein, Keely; Finkelstein, Steven; Frye, Brenda; Gerin, Maryvonne;
2014-01-01
We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup -1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup -1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup -1) and (standard deviation)g 4 kms(sup -1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup -1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.
Quantifying the heterogeneity of the tectonic stress field using borehole data
Schoenball, Martin; Davatzes, Nicholas C.
2017-01-01
The heterogeneity of the tectonic stress field is a fundamental property which influences earthquake dynamics and subsurface engineering. Self-similar scaling of stress heterogeneities is frequently assumed to explain characteristics of earthquakes such as the magnitude-frequency relation. However, observational evidence for such scaling of the stress field heterogeneity is scarce.We analyze the local stress orientations using image logs of two closely spaced boreholes in the Coso Geothermal Field with sub-vertical and deviated trajectories, respectively, each spanning about 2 km in depth. Both the mean and the standard deviation of stress orientation indicators (borehole breakouts, drilling-induced fractures and petal-centerline fractures) determined from each borehole agree to the limit of the resolution of our method although measurements at specific depths may not. We find that the standard deviation in these boreholes strongly depends on the interval length analyzed, generally increasing up to a wellbore log length of about 600 m and constant for longer intervals. We find the same behavior in global data from the World Stress Map. This suggests that the standard deviation of stress indicators characterizes the heterogeneity of the tectonic stress field rather than the quality of the stress measurement. A large standard deviation of a stress measurement might be an expression of strong crustal heterogeneity rather than of an unreliable stress determination. Robust characterization of stress heterogeneity requires logs that sample stress indicators along a representative sample volume of at least 1 km.
Altuntepe, Emrah; Emel'yanenko, Vladimir N; Forster-Rotgers, Maximilian; Sadowski, Gabriele; Verevkin, Sergey P; Held, Christoph
2017-10-01
Levulinic acid was esterified with methanol, ethanol, and 1-butanol with the final goal to predict the maximum yield of these equilibrium-limited reactions as function of medium composition. In a first step, standard reaction data (standard Gibbs energy of reaction Δ R g 0 ) were determined from experimental formation properties. Unexpectedly, these Δ R g 0 values strongly deviated from data obtained with classical group contribution methods that are typically used if experimental standard data is not available. In a second step, reaction equilibrium concentrations obtained from esterification catalyzed by Novozym 435 at 323.15 K were measured, and the corresponding activity coefficients of the reacting agents were predicted with perturbed-chain statistical associating fluid theory (PC-SAFT). The so-obtained thermodynamic activities were used to determine Δ R g 0 at 323.15 K. These results could be used to cross-validate Δ R g 0 from experimental formation data. In a third step, reaction-equilibrium experiments showed that equilibrium position of the reactions under consideration depends strongly on the concentration of water and on the ratio of levulinic acid: alcohol in the initial reaction mixtures. The maximum yield of the esters was calculated using Δ R g 0 data from this work and activity coefficients of the reacting agents predicted with PC-SAFT for varying feed composition of the reaction mixtures. The use of the new Δ R g 0 data combined with PC-SAFT allowed good agreement to the measured yields, while predictions based on Δ R g 0 values obtained with group contribution methods showed high deviations to experimental yields.
Tomblinson, C M; Cheng, M-R; Lal, D; Hoxworth, J M
2016-07-01
Inferior turbinate hypertrophy and concha bullosa often occur opposite the direction of nasal septal deviation. The objective of this retrospective study was to determine whether a concha bullosa impacts inferior turbinate hypertrophy in patients who have nasal septal deviation. The electronic medical record was used to identify sinus CT scans exhibiting nasal septal deviation for 100 adult subjects without and 100 subjects with unilateral middle turbinate concha bullosa. Exclusion criteria included previous sinonasal surgery, tumor, sinusitis, septal perforation, and craniofacial trauma. Nasal septal deviation was characterized in the coronal plane by distance from the midline (severity) and height from the nasal floor. Measurement differences between sides for inferior turbinate width (overall and bone), medial mucosa, and distance to the lateral nasal wall were calculated as inferior turbinate hypertrophy indicators. The cohorts with and without concha bullosa were similarly matched for age, sex, and nasal septal deviation severity, though nasal septal deviation height was greater in the cohort with concha bullosa than in the cohort without concha bullosa (19.1 ± 4.3 mm versus 13.5 ± 4.1 mm, P < .001). Compensatory inferior turbinate hypertrophy was significantly greater in the cohort without concha bullosa than in the cohort with it as measured by side-to-side differences in turbinate overall width, bone width, and distance to the lateral nasal wall (P < .01), but not the medial mucosa. Multiple linear regression analyses found nasal septal deviation severity and height to be significant predictors of inferior turbinate hypertrophy with positive and negative relationships, respectively (P < .001). Inferior turbinate hypertrophy is directly proportional to nasal septal deviation severity and inversely proportional to nasal septal deviation height. The effect of a concha bullosa on inferior turbinate hypertrophy is primarily mediated through influence on septal morphology, because the nasal septal deviation apex tends to be positioned more superior from the nasal floor in these patients. © 2016 by American Journal of Neuroradiology.
77 FR 25590 - Drawbridge Operation Regulation; Lake Washington Ship Canal, Seattle, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-01
...The Coast Guard has issued a temporary deviation from the operating schedule that governs University Bridge across the Lake Washington Ship Canal, mile 4.3, at Seattle, WA. This deviation is necessary to accommodate the Beat the Bridge charity foot race scheduled for Sunday, May 20, 2012. This deviation allows the bridge to remain in the closed position to allow safe movement of event participants.
77 FR 25079 - Drawbridge Operation Regulation; Lake Washington Ship Canal, Seattle, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
...The Coast Guard has issued a temporary deviation from the operating schedule that governs the Montlake Bridge across the Lake Washington Ship Canal, mile 5.2, at Seattle, WA. This deviation is necessary to accommodate the Beat the Bridge charity foot race scheduled for Sunday, May 20, 2012. This deviation allows the bridge to remain in the closed position to allow safe movement of event participants.
78 FR 79312 - Drawbridge Operation Regulation; Upper Mississippi River, Rock Island, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
...The Coast Guard has issued a temporary deviation from the operating schedule that governs the Rock Island Railroad and Highway Drawbridge across the Upper Mississippi River, mile 482.9, at Rock Island, Illinois. The deviation is necessary to allow the St. Patrick's Day Road Race to cross the bridge. This deviation allows the bridge to be maintained in the closed-to-navigation position for two hours.
Mandal, Guruprasad; Srinivas, V; Rao, V V
2011-03-01
The granular structure and electrical transport behavior of ball milled magnetic permalloy particles and graphite forming (Ni0.8Fe0.2)10C90 granular composites have been reported. Retaining the composite composition to be 90:10 and varying the particle size of permalloy, the electronic transport properties have been carried out down to 4 K under the external applied magnetic field of 50 kOe. All the samples show semiconducting like behavior and positive magnetoresistance (MR) in the temperature range 4-300 K. A strong anisotropic magnetoresistance in these samples has also been observed. The highest 31% longitudinal and 6.8% transverse magnetoresistance values have been observed in 40 hrs ball milled (Ni0.8Fe0.2)10C90 composite. From these studies, we suggest that the magnetic component present in the sample may not be playing a major role in obtaining large positive MR values, which is in deviation with the earlier reports.
Indo-Pacific sea level variability during recent decades
NASA Astrophysics Data System (ADS)
Yamanaka, G.; Tsujino, H.; Nakano, H.; Urakawa, S. L.; Sakamoto, K.
2016-12-01
Decadal variability of sea level in the Indo-Pacific region is investigated using a historical OGCM simulation. The OGCM driven by the atmospheric forcing removing long-term trends clearly exhibits decadal sea level variability in the Pacific Ocean, which is associated with eastern tropical Pacific thermal anomalies. During the period of 1977-1987, the sea level anomalies are positive in the eastern equatorial Pacific and show deviations from a north-south symmetric distribution, with strongly negative anomalies in the western tropical South Pacific. During the period of 1996-2006, in contrast, the sea level anomalies are negative in the eastern equatorial Pacific and show a nearly north-south symmetric pattern, with positive anomalies in both hemispheres. Concurrently, sea level anomalies in the south-eastern Indian Ocean vary with those in the western tropical Pacific. These sea level variations are closely related to large-scale wind fields. Indo-Pacific sea level distributions are basically determined by wind anomalies over the equatorial region as well as wind stress curl anomalies over the off-equatorial region.
Fortmann, Carsten; Wierling, August; Röpke, Gerd
2010-02-01
The dynamic structure factor, which determines the Thomson scattering spectrum, is calculated via an extended Mermin approach. It incorporates the dynamical collision frequency as well as the local-field correction factor. This allows to study systematically the impact of electron-ion collisions as well as electron-electron correlations due to degeneracy and short-range interaction on the characteristics of the Thomson scattering signal. As such, the plasmon dispersion and damping width is calculated for a two-component plasma, where the electron subsystem is completely degenerate. Strong deviations of the plasmon resonance position due to the electron-electron correlations are observed at increasing Brueckner parameters r(s). These results are of paramount importance for the interpretation of collective Thomson scattering spectra, as the determination of the free electron density from the plasmon resonance position requires a precise theory of the plasmon dispersion. Implications due to different approximations for the electron-electron correlation, i.e., different forms of the one-component local-field correction, are discussed.
Extraocular muscle proprioception and eye position.
Pettorossi, V E; Ferraresi, A; Draicchio, F; Errico, P; Santarelli, R; Manni, E
1995-03-01
In the lamb, acute unilateral section of the ophthalmic branch induced in the ipsilateral eye occasional oscillations of the resting position and misalignment of the horizontal vestibulo-ocular reflex (HVOR) with respect to the stimulus. Additional electrolytic lesion of the cells innervating the proprioceptors of the medial rectus muscle, or of the lateral rectus muscle in the contralateral semilunar ganglion, provoked a 4 degrees-7 degrees consensual eye deviation towards and away from the lesioned side, respectively. The optokinetic beating field was similarly deviated. Under these experimental conditions, HVOR showed enhanced gain and marked misalignment in both eyes. Therefore, the selective suppression of muscular proprioceptive input deviated both eyes towards the direction opposite to the muscle whose gangliar proprioceptive representation has been destroyed.
Differential processing of melodic, rhythmic and simple tone deviations in musicians--an MEG study.
Lappe, Claudia; Lappe, Markus; Pantev, Christo
2016-01-01
Rhythm and melody are two basic characteristics of music. Performing musicians have to pay attention to both, and avoid errors in either aspect of their performance. To investigate the neural processes involved in detecting melodic and rhythmic errors from auditory input we tested musicians on both kinds of deviations in a mismatch negativity (MMN) design. We found that MMN responses to a rhythmic deviation occurred at shorter latencies than MMN responses to a melodic deviation. Beamformer source analysis showed that the melodic deviation activated superior temporal, inferior frontal and superior frontal areas whereas the activation pattern of the rhythmic deviation focused more strongly on inferior and superior parietal areas, in addition to superior temporal cortex. Activation in the supplementary motor area occurred for both types of deviations. We also recorded responses to similar pitch and tempo deviations in a simple, non-musical repetitive tone pattern. In this case, there was no latency difference between the MMNs and cortical activation was smaller and mostly limited to auditory cortex. The results suggest that prediction and error detection of musical stimuli in trained musicians involve a broad cortical network and that rhythmic and melodic errors are processed in partially different cortical streams. Copyright © 2015 Elsevier Inc. All rights reserved.
Relaxation of Fermionic Excitations in a Strongly Attractive Fermi Gas in an Optical Lattice
2011-09-27
decreases both with temperature and deviation of the fermion density from half filling. We show that quasiparticle and phase degrees of freedom are...the interaction strength to the bandwidth of the system. Thus, at strong coupling, the fermionic quasiparticles and the motion of the bosonic molecules
Analysis of DGPS/INS and MLS/INS final approach navigation errors and control performance data
NASA Technical Reports Server (NTRS)
Hueschen, Richard M.; Spitzer, Cary R.
1992-01-01
Flight tests were conducted jointly by NASA Langley Research Center and Honeywell, Inc., on a B-737 research aircraft to record a data base for evaluating the performance of a differential DGPS/inertial navigation system (INS) which used GPS Course/Acquisition code receivers. Estimates from the DGPS/INS and a Microwave Landing System (MLS)/INS, and various aircraft parameter data were recorded in real time aboard the aircraft while flying along the final approach path to landing. This paper presents the mean and standard deviation of the DGPS/INS and MLS/INS navigation position errors computed relative to the laser tracker system and of the difference between the DGPS/INS and MLS/INS velocity estimates. RMS errors are presented for DGPS/INS and MLS/INS guidance errors (localizer and glideslope). The mean navigation position errors and standard deviation of the x position coordinate of the DGPS/INS and MLS/INS systems were found to be of similar magnitude while the standard deviation of the y and z position coordinate errors were significantly larger for DGPS/INS compared to MLS/INS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Z; Reyhan, M; Huang, Q
Purpose: The calibration of the Hounsfield units (HU) to relative proton stopping powers (RSP) is a crucial component in assuring the accurate delivery of proton therapy dose distributions to patients. The purpose of this work is to assess the uncertainty of CT calibration considering the impact of CT slice thickness, position of the plug within the phantom and phantom sizes. Methods: Stoichiometric calibration method was employed to develop the CT calibration curve. Gammex 467 tissue characterization phantom was scanned in Tomotherapy Cheese phantom and Gammex 451 phantom by using a GE CT scanner. Each plug was individually inserted into themore » same position of inner and outer ring of phantoms at each time, respectively. 1.25 mm and 2.5 mm slice thickness were used. Other parameters were same. Results: HU of selected human tissues were calculated based on fitted coefficient (Kph, Kcoh and KKN), and RSP were calculated according to the Bethe-Bloch equation. The calibration curve was obtained by fitting cheese phantom data with 1.25 mm thickness. There is no significant difference if the slice thickness, phantom size, position of plug changed in soft tissue. For boney structure, RSP increases up to 1% if the phantom size and the position of plug changed but keep the slice thickness the same. However, if the slice thickness varied from the one in the calibration curve, 0.5%–3% deviation would be expected depending on the plug position. The Inner position shows the obvious deviation (averagely about 2.5%). Conclusion: RSP shows a clinical insignificant deviation in soft tissue region. Special attention may be required when using a different slice thickness from the calibration curve for boney structure. It is clinically practical to address 3% deviation due to different thickness in the definition of clinical margins.« less
Chen, Xiaomei; Longstaff, Andrew; Fletcher, Simon; Myers, Alan
2014-04-01
This paper presents and evaluates an active dual-sensor autofocusing system that combines an optical vision sensor and a tactile probe for autofocusing on arrays of small holes on freeform surfaces. The system has been tested on a two-axis test rig and then integrated onto a three-axis computer numerical control (CNC) milling machine, where the aim is to rapidly and controllably measure the hole position errors while the part is still on the machine. The principle of operation is for the tactile probe to locate the nominal positions of holes, and the optical vision sensor follows to focus and capture the images of the holes. The images are then processed to provide hole position measurement. In this paper, the autofocusing deviations are analyzed. First, the deviations caused by the geometric errors of the axes on which the dual-sensor unit is deployed are estimated to be 11 μm when deployed on a test rig and 7 μm on the CNC machine tool. Subsequently, the autofocusing deviations caused by the interaction of the tactile probe, surface, and small hole are mathematically analyzed and evaluated. The deviations are a result of the tactile probe radius, the curvatures at the positions where small holes are drilled on the freeform surface, and the effect of the position error of the hole on focusing. An example case study is provided for the measurement of a pattern of small holes on an elliptical cylinder on the two machines. The absolute sum of the autofocusing deviations is 118 μm on the test rig and 144 μm on the machine tool. This is much less than the 500 μm depth of field of the optical microscope. Therefore, the method is capable of capturing a group of clear images of the small holes on this workpiece for either implementation.
Schwarz, T; Weber, M; Wörner, M; Renkawitz, T; Grifka, J; Craiovan, B
2017-05-01
Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text] for inclination. This novel calculation for central beam offset correction enables highly accurate measurement of the cup position.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hancock, S; Clements, C; Hyer, D
2016-06-15
Purpose: To develop and demonstrate application of a method that characterizes deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter as a function of gantry, collimator, and table variables. Methods: A set of Winston-Lutz ball-bearing images was used to determine the gantry radiation isocenter as the midrange of deviation values resulting from gantry and collimator rotation. Also determined were displacement of table axis from gantry isocenter and recommended table axis adjustment. The method, previously reported, has been extended to include the effect of collimator walkout by obtaining measurements with 0 and 180 degree collimator rotation formore » each gantry angle. Twelve images were used to characterize the volumetric isocenter for the full range of available gantry, collimator, and table rotations. Results: Three Varian True Beam, two Elekta Infinity and four Versa HD linacs at five institutions were tested using identical methodology. Varian linacs exhibited substantially less deviation due to head sag than Elekta linacs (0.4 mm vs. 1.2 mm on average). One linac from each manufacturer had additional isocenter deviation of 0.3 to 0.4 mm due to jaw instability with gantry and collimator rotation. For all linacs, the achievable isocenter tolerance was dependent on adjustment of collimator position offset, transverse position steering, and alignment of the table axis with gantry isocenter, facilitated by these test results. The pattern and magnitude of table axis wobble vs. table angle was reproducible and unique to each machine. Conclusion: This new method provides a comprehensive set of isocenter deviation values including all variables. It effectively facilitates minimization of deviation between beam center and target (ball-bearing) position. This method was used to quantify the effect of jaw instability on isocenter deviation and to identify the offending jaw. The test is suitable for incorporation into a routine machine QA program. Software development was performed by Radiological Imaging Technology, Inc.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, N; DiCostanzo, D; Fullenkamp, M
2015-06-15
Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
You, T; Dang, J; Dai, C
2015-06-15
Purpose: To evaluate dosimetric impact of spinal SBRT when MLC leaf positions deviate from planning positions for different energies and doserates. Methods and Materials: 18 localized spinal metastases patients were selected for SBRT using IMRT planning with 9 posterior beams delivered at gantry angles ranging between 100°–260°. A modern linear accelerator(Varian Turebeam STX with HDMLC 2.5 mm thick leaf at isocenter) IMRT plans were generated using both 6X and 6X-FFF(Flattening filter free) beams with a nominal prescription dose of 6 Gy/fraction to PTV. Doserates ranging from 200–600 MU/min for 6X and 400–1400 MU/min for 6X-FFF, with 200 increments were examined.more » A fixed amount(0.3, 0.5, 1, and 2 mm) of MLC-leaf position deviation was simulated to each plan under following conditions: 1)only along X1 collimator; 2)with increments at both X1 and X2 collimator directions;3)with reductions at both X1 and X2 collimator directions. Dose was recalculated for each modified plans. Both original and modified plans were delivered using Turebeam STX machine and measured using both portal dosimetry and a 3D dosimeter(Delta4 of ScandiDos). Each field’s Result were compared using following three parameters: the 95% iso-dose level Conformal Index(95%CI), the spinal cord maximum dose(SCDmax), and the planned target volume(PTV) mean dose. Results: Dosimetric impacts on the 95%CI, SCDmax and the PTV mean dose are: 1)negligible if MLC-leaf position deviation only along a single collimator direction ≥1.0 mm,2)substantial if MLC-leaf position increment along both collimator directions ≥0.3 mm(95% CI decreases while SCDmax and PTV mean-dose increase), 3)substantial if MLC-leaf position reduction along both collimator directions ≥0.3 mm(95% CI first increases and then decreases while SCDmax and PTV mean-dose decrease). Different energies and doserates demonstrated comparable dosimetric impacts. Conclusion: Substantial dose deviations could happen for spinal SBRT using IMRT plan with HD-MLC if leaf position deviation ≥0.3 mm. The effects of different energy and doserate are negligible.« less
Ghosh, Payel; Chandler, Adam G; Hobbs, Brian P; Sun, Jia; Rong, John; Hong, David; Subbiah, Vivek; Janku, Filip; Naing, Aung; Hwu, Wen-Jen; Ng, Chaan S
The aim of this study was to quantify the effect of shuttling on computed tomography perfusion (CTp) parameters derived from shuttle-mode body CT images using aortic inputs from different table positions. Axial shuttle-mode CT scans were acquired from 6 patients (10 phases, 2 nonoverlapping table positions 1.4 seconds apart) after contrast agent administration. Artifacts resulting from the shuttling motion were corrected with nonrigid registration before computing CTp maps from 4 aortic levels chosen from the most superior and inferior slices of each table position scan. The effect of shuttling on CTp parameters was estimated by mean differences in mappings obtained from aortic inputs in different table positions. Shuttling effect was also quantified using 95% limits of agreement of CTp parameter differences within-table and between-table aortic positions from the interaortic mean CTp values. Blood flow, permeability surface, and hepatic arterial fraction differences were insignificant (P > 0.05) for both within-table and between-table comparisons. The 95% limits of agreement for within-table blood volume (BV) value deviations obtained from lung tumor regions were less than 4.7% (P = 0.18) compared with less than 12.2% (P = 0.003) for between-table BV value deviations. The 95% limits of agreement of within-table deviations for liver tumor regions were less than 1.9% (P = 0.55) for BV and less than 3.2% (P = 0.23) for mean transit time, whereas between-table BV and mean transit time deviations were less than 11.7% (P < 0.01) and less than 14.6% (P < 0.01), respectively. Values for normal liver tissue regions were concordant. Computed tomography perfusion parameters acquired from aortic levels within-table positions generally yielded higher agreement than mappings obtained from aortic levels between-table positions indicating differences due to shuttling effect.
WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, S; Molloy, J
Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages formore » 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.« less
Radar sea reflection for low-e targets
NASA Astrophysics Data System (ADS)
Chow, Winston C.; Groves, Gordon W.
1998-09-01
Modeling radar signal reflection from a wavy sea surface uses a realistic characteristic of the large surface features and parameterizes the effect of the small roughness elements. Representation of the reflection coefficient at each point of the sea surface as a function of the Specular Deviation Angle is, to our knowledge, a novel approach. The objective is to achieve enough simplification and retain enough fidelity to obtain a practical multipath model. The 'specular deviation angle' as used in this investigation is defined and explained. Being a function of the sea elevations, which are stochastic in nature, this quantity is also random and has a probability density function. This density function depends on the relative geometry of the antenna and target positions, and together with the beam- broadening effect of the small surface ripples determined the reflectivity of the sea surface at each point. The probability density function of the specular deviation angle is derived. The distribution of the specular deviation angel as function of position on the mean sea surface is described.
Ethyl 2-[(carbamothioylamino)imino]propanoate
Corrêa, Charlane C.; Graúdo, José Eugênio J.C.; de Oliveira, Luiz Fernando C.; de Almeida, Mauro V.; Diniz, Renata
2011-01-01
The title compound, C6H11N3O2S, consists of a roughly planar molecule (r.m.s deviation from planarity = 0.077 Å for the non-H atoms) and has the S atom in an anti position to the imine N atom. This N atom is the acceptor of a strongly bent internal N—H⋯N hydrogen bond donated by the amino group. In the crystal, molecules are arranged in undulating layers parallel to (010). The molecules are linked via intermolecular amino–carboxyl N—H⋯O hydrogen bonds, forming chains parallel to [001]. The chains are cross-linked by Ncarbazone—H⋯S and C—H⋯S interactions, forming infinite sheets. PMID:22091006
Turbulent Boundary Layers in Oscillating Flows. Part 1: an Experimental and Computational Study
NASA Technical Reports Server (NTRS)
Cook, W. J.
1986-01-01
An experimental-computational study of the behavior of turbulent boundary layers for oscillating air flows over a plane surface with a small favorable mean pressure gradient is described. Experimental studies were conducted for boundary layers generated on the test section wall of a facility that produces a flow with a mean free stream velocity and a superposed nearly-pure sinusoidal component over a wide range of frequency. Flow at a nominal mean free stream velocity of 50 m/s were studied at atmospheric pressure and temperature at selected axial positions over a 2 m test length for frequencies ranging from 4 to 29 Hz. Quantitative experimental results are presented for unsteady velocity profiles and longitudinal turbulence levels obtained from hot wire anemometer measurements at three axial positions. Mean velocity profiles for oscillating flows were found to exhibit only small deviations from corresponding steady flow profiles, while amplitudes and phase relationships exhibited a strong dependence on axial position and frequency. Since sinusoidal flows could be generated over a wide range of frequency, studies at fixed values of reduced frequency at different axial positions were studied. Results show that there is some utility in the use of reduced frequency to correlate unsteady velocity results. The turbulence level u' sub rms was observed to vary essentially sinusoidally around values close to those measured in steady flow. However, the amplitude of oscillation and phase relations for turbulence level were found to be strongly frequency dependent. Numerical predictions were obtained using an unsteady boundary layer computational code and the Cebeci-Smith and Glushko turbulence models. Predicted quantities related to unsteady velocity profiles exhibit fair agreement with experiment when the Cebeci-Smith turbulence model is used.
Frisén, Lars
2010-12-01
Deviations of the subjective visual vertical in the roll or fronto-parallel plane occur commonly in disorders of the brainstem and have been extensively explored. In contrast, little is known about deviations in other directions. The present retrospective study focused on deviations in the pitch (sagittal) direction in 176 patients with a wide variety of disorders. The test task was to set a self-illuminated rod in the apparent upright position, in total darkness. Abnormal results (outside ± 4°) were recorded in 58% of the subjects. Negative (top backward) deviations were the most common, particularly with mass lesions in the pineal region, obstructive hydrocephalus, cerebellar lesions and crowding at the craniocervical junction. Positive and negative deviations were about equally common with focal intra-axial lesions. Negative deviations appeared related to dorsal locations of lesions and vice versa. Normal pressure hydrocephalus, Parkinson's disease and progressive supranuclear palsy were associated with smaller deviations, without a clear directional preponderance, and a larger individual variability. Most subjects lacked overt clinical corollaries. The most common ocular signs were aqueduct syndromes (n = 17) and ocular tilt reactions (n = 12), which were associated with deviations in 47 and 92% of instances, respectively. Subjective corollaries of deviation were never reported, not even by those subjects who showed a dramatic improvement upon resolution of the underlying condition. Deviations were also assessed in roll in a subgroup of 40 patients with focal lesions. Thirty subjects returned abnormal results: 13% in roll, 47% in pitch and 40% in pitch and roll. The direction of roll deviation appeared primarily related to laterality, with clockwise deviations with right-sided lesions and vice versa. All subjects with ocular tilt reactions had combined pitch and roll deviations, implying a common neural substrate. Correlation analyses, geometrical modelling and experimental self-observations indicated that deviations in pitch were attributable to cyclotorsional asymmetries between the eyes. The frequent co-existence of abnormal pitch and roll results implies that the true axis of deviation in focal brainstem disorders commonly falls outside traditional reference planes. The term 'visual upright in three dimensions' is suggested to identify unrestricted measurements, preserving the established term 'visual vertical' for measurements confined to the roll plane. Assessment of the visual upright in three dimensions provides a new, quantitative angle on brainstem disorders. The test appears useful for identifying a ubiquitous yet clinically silent feature of brainstem disease and also for monitoring the evolution of underlying conditions. More detailed explorations appear well motivated.
Stable isotope chemistry of fossil bone as a new paleoclimate indicator
NASA Astrophysics Data System (ADS)
Kohn, Matthew J.; Law, J. Mclver
2006-02-01
During fossilization, bone is thought to recrystallize and alter chemically on timescales of kyr to a few tens of kyr, i.e., similar to the timescale for formation of soils. Therefore, C- and O-isotope compositions of bone apatite should correlate with trends in soil water composition and aridity, and serve as paleoclimate indicators. This hypothesis was tested by analyzing C- and O-isotope compositions of the CO 3 component of fossil bone apatite from mid-Oligocene through late Pleistocene units in Oregon and western Idaho, including the John Day (19.4-30.0 Ma), Mascall (15.2-15.8 Ma), and Rattlesnake (7.2-7.8 Ma) Formations, whose paleosol sequences have been studied in detail, and the Juntura (10-11 Ma), Hagerman (3.2 Ma), and Fossil Lake (<23-650 ka) fossil localities. Tooth enamel δ18O values provide a baseline of meteoric water compositions. Stable isotope compositions of bone CO 3 do change in response to broad climatic trends, but show poor correlation with compositions of corresponding paleosol CO 3 at specific horizons. Instead, compositional deviations between bone and paleosol CO 3 correlate with compositional deviations with the next higher paleosol; this suggests that the timescale for fossilization exceeds one paleosol cycle. Based on stratigraphic evidence and simple alteration models, fossilization timescales are estimated at 20-50 kyr, indicating that bone CO 3 will prove most useful for sequences spanning >100 kyr. C-isotopes show negative and strong positive deviations during wet and dry climates respectively, and short-term trends correspond well with changes in aridity within the Mascall and Rattlesnake Formations, as inferred from paleosols. A proposed correction to δ18O values based on δ13C anomalies implies a small, ˜1.5‰ increase in meteoric water δ18O during the late Oligocene global warming event, consistent with a minimum temperature increase of ˜4 °C. A strong inferred decrease in δ18O of 4-5‰ after 7 Ma closely parallels compositional changes in tooth enamel, and reflects a doubling in the height of the Cascade Range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang Meizhen; Shi Longzhao; Wang Yuxing
2006-08-15
An inherently nonlinear relation between the output current of the tetralateral position sensitive detector (PSD) and the position of the incident light spot has been found theoretically. Based on single-chip microcomputer and the theoretical relation between output current and position, a new signal processor capable of correcting nonlinearity and reducing position measurement deviation of tetralateral PSD was developed. A tetralateral PSD (S1200, 13x13 mm{sup 2}, Hamamatsu Photonics K.K.) was measured with the new signal processor, a linear relation between the output position of the PSD, and the incident position of the light spot was obtained. In the 60% range ofmore » a 13x13 mm{sup 2} active area, the position nonlinearity (rms) was 0.15% and the position measurement deviation (rms) was {+-}20 {mu}m. Compared with traditional analog signal processor, the new signal processor is of better compatibility, lower cost, higher precision, and easier to be interfaced.« less
NASA Astrophysics Data System (ADS)
Huang, Mei-Zhen; Shi, Long-Zhao; Wang, Yu-Xing; Ni, Yi; Li, Zhen-Qing; Ding, Hai-Feng
2006-08-01
An inherently nonlinear relation between the output current of the tetralateral position sensitive detector (PSD) and the position of the incident light spot has been found theoretically. Based on single-chip microcomputer and the theoretical relation between output current and position, a new signal processor capable of correcting nonlinearity and reducing position measurement deviation of tetralateral PSD was developed. A tetralateral PSD (S1200, 13×13mm2, Hamamatsu Photonics K.K.) was measured with the new signal processor, a linear relation between the output position of the PSD, and the incident position of the light spot was obtained. In the 60% range of a 13×13mm2 active area, the position nonlinearity (rms) was 0.15% and the position measurement deviation (rms) was ±20μm. Compared with traditional analog signal processor, the new signal processor is of better compatibility, lower cost, higher precision, and easier to be interfaced.
78 FR 26249 - Drawbridge Operation Regulation; Lake Washington Ship Canal, Seattle, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
...The Coast Guard has issued a temporary deviation from the operating schedule that governs the Montlake Bridge across the Lake Washington Ship Canal, mile 5.2, at Seattle, WA, and the University Bridge across the Lake Washington Ship Canal, mile 4.3, at Seattle, WA. This deviation is necessary to accommodate the ``Beat the Bridge'' foot race. This deviation allows the bridges to remain in the closed position to allow safe movement of event participants.
NASA Astrophysics Data System (ADS)
Panda, S. K.; Gedam, S. S.; Rajaram, G.
2015-04-01
The present study investigates variation of the ionospheric total electron content (TEC) in the low latitude Indian sub-continental region from the GPS observations and its comparison with the global ionosphere maps (GIMs), standard international reference ionosphere (IRI 2012), and the standard plasmasphere-ionosphere model (SPIM) for the period from November 2011 to October 2012 that corresponds to the progressive phase towards the midst of the solar cycle-24. Observations during quiet period show diurnal maximum of TEC occurring around 14:00-16:00 IST, with relatively broader and longer duration of local maximum at Bangalore and behave reversely towards Delhi. The secondary maximum of TEC was markedly noticeable at Bangalore during the months of March and September, and only in the month of September at Hyderabad and Mumbai. However, the relatively higher TEC during December month than the June is ascribed to the winter anomaly which is more prevalent during the high solar activity periods. The prevailing instability in latitudes of anomaly crest during January 2012 is possibly due to the seasonal variation of lunar tidal effects, modulating the EEJ strength at the equator. The studies covered the period of a strong geomagnetic storm during 6-11 March 2012 (SYM-H: -149 nT) which resulted in positive deviation of GPS-TEC at Bangalore (↑ 20%), Hyderabad (↑ 22%), and Lucknow (↑ 94%) compared to the mean quiet days level. The relatively large deviation of TEC at Lucknow could be attributed to the poleward shifting of the anomaly crest, manifested by enhanced fountain effect at the equator. Studies confirm excellent agreement (80-85%) of GPS-TEC with IGS-GIM at Bangalore and Hyderabad with the exception of the night-time hours (Deviations >50%). However relatively larger deviation of GPS-TEC from GIM-TEC at Delhi could be due to the unavailability of IGS stations in the proximity of the position. Predictions of the SPIM model (extension of IRI up to GPS altitude) exhibit much higher deviation from the in situ GPS observations as well as GIM and IRI outputs during quiet periods. Correspondingly, either of the models (IRI and SPIM) did not respond well to the arrival of the sudden storm commencements (SSCs) during the storm period (6-11 March 2012). When SPIM is used instead of IRI, the overestimation from GPS-TECs are further exaggerated by 13-18% (December solstice), 27-37% (March equinox), 15-31% (June solstice), and 20-32% (September equinox) during peak hours of the period. We attribute the relatively more deviation of the SPIM than the IRI model possibly due to its plasmaspheric extension to the IRI model by adding the Russian SMI model of high latitude characteristics. Hence, we emphasize the further improvement in the model with due consideration of the driving forces at play in the region, for reliable predictions of the low latitude ionosphere.
Nonlinear elastic effects on the energy flux deviation of ultrasonic waves in gr/ep composites
NASA Technical Reports Server (NTRS)
Prosser, William H.; Kriz, R. D.; Fitting, Dale W.
1992-01-01
The effects of nonlinear elasticity on energy flux deviation in undirectional gr/ep composites are examined. The shift in the flux deviation is modeled using acoustoelasticity theory and the second- and third-order elastic stiffness coefficients for T300/5208 gr/ep. Two conditions of applied uniaxial stress are considered. In the first case, the direction of applied uniaxial stress was along the fiber axis (x3), while in the second case it was perpendicular to the fiber axis along the laminate stacking direction (x1). For both conditions, the change in the energy flux deviation angle from the condition of zero applied stress is computed over the range of propagation directions of 0 to 60 deg from the fiber axis at two-degree intervals. A positive flux deviation angle implies the energy deviates away from the fiber direction toward the x1 axis, while a negative deviation means that the energy deviates toward the fibers. Over this range of fiber orientation angles, the energy of the quasi-longitudinal and pure mode transverse waves deviates toward the fibers, while that of the quasi-transverse mode deviates away from the fibers.
Software Obfuscation With Symmetric Cryptography
2008-03-01
of y = a * b + c Against Random Functions ...............84 Appendix C: Black-box Analysis of Fibonacci Against Random Functions...Metric ................... 67 Figure 19. Standard Deviations of All Fibonacci Output Bits by Metric ........................ 67 Figure 20...caveat to encryption strength is that what may be strong presently may not always be strong; the Data Encryption Standard ( DES ) was once considered
Trajectory Control of Small Rotating Projectiles by Laser Sparks
NASA Astrophysics Data System (ADS)
Starikovskiy, Andrey; Limbach, Christopher; Miles, Richard
2015-09-01
The possibility of controlling the trajectory of the supersonic motion of a rotating axisymmetric projectile using a remotely generated laser spark was investigated. The dynamic images of the interaction of thermal inhomogeneity created by the laser spark with the bow shock in front of the projectile were obtained. The criterion for a strong shock wave interaction with the thermal inhomogeneity at different angles of a shock wave was derived. Significant changes in the configuration of the bow shock wave and changes in the pressure distribution over the surface of the rotating projectile can appear for laser spark temperature of T' = 2500-3000 K. The experiment showed that strong interaction takes place for both plane and oblique shock waves. The measurement of the velocity of the precession of the rotating projectile axis from the initial position in time showed that the angle of attack of the projectile deviates with a typical time of perturbation propagation along the projectile's surface. Thus the laser spark can change the trajectory of the rotating projectile, moving at supersonic speed, through the creation of thermal heterogeneity in front of it.
Shapes of strong shock fronts in an inhomogeneous solar wind
NASA Technical Reports Server (NTRS)
Heinemann, M. A.; Siscoe, G. L.
1974-01-01
The shapes expected for solar-flare-produced strong shock fronts in the solar wind have been calculated, large-scale variations in the ambient medium being taken into account. It has been shown that for reasonable ambient solar wind conditions the mean and the standard deviation of the east-west shock normal angle are in agreement with experimental observations including shocks of all strengths. The results further suggest that near a high-speed stream it is difficult to distinguish between corotating shocks and flare-associated shocks on the basis of the shock normal alone. Although the calculated shapes are outside the range of validity of the linear approximation, these results indicate that the variations in the ambient solar wind may account for large deviations of shock normals from the radial direction.
77 FR 37316 - Drawbridge Operation Regulation; Trent River, New Bern, NC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... navigation position for 3 hours to accommodate the annual Neuse River Bridge Run. DATES: This deviation is...) 366-9826. SUPPLEMENTARY INFORMATION: The Event Director for the Neuse River Bridge Run, with approval... temporary deviation from the current operating schedule to accommodate the Neuse River Bridge Run. The...
Li, W T; Chen, X Z; Tu, W J; Huang, Z Z; Chang, L H; Wang, J; Zhang, G H
2016-09-07
Objective: To investigate the psychopathological characteristics in patients with deviation of nasal septum. Methods: Between May 2015 and December 2015, fourty-four patients with deviated nasal septum and 37 patients with vocal cord polyp as control were included in this study. Psychological characteristics were evaluated by a series of questionnaire instruments including symptom checklist-90 (SCL-90), self-rating depression scale (SDS) and self-rating anxiety scale (SAS). Visual analogue scale (VAS) and rhinomanometry through front nostril were used to evaluate nasal symptom. The correlation between psychological characteristics and nasal symptom was evaluated. SPSS 20.0 software was used to analyze the data. Results: The SCL-90 score in nasal septal deviation group was 130.4±48.3. The total score and total average score of SCL-90 had no significant difference between nasal septal deviation group and the Chinese standard or control group( t value was 0.469, 0.112, 1.575, 1.564, respectively, all P >0.05). The scores of somatization, depression and anxiety factors in nasal septal deviation group were higher than control group ( t value was 2.380, 2.133, 1.969, respectively, all P <0.05). The proportion of positive patients in these three factors between nasal septal deviation group and control group had significant differences (χ 2 value was 11.585, 9.610, 5.429, respectively, all P <0.05). The scores of SDS and SAS in nasal septal deviation group were 46.0±10.6 and 43.0±10.2, which were higher than that in the Chinese standard and control group ( t value was 5.342, 6.236, 1.476, 3.013, respectively, all P <0.05). There were 9 patients companying with depression or anxiety (20.5%, 20.5%, respectively) and 5 patients companying with depression and anxiety in nasal septal deviation group (11.4%). There were positive correlation not only between the scores of SDS and the depression factor of SCL-90 but also between the scores of SAS and the anxiety factor of SCL-90 ( Z =0.415, P =0.005, Z =0.445, P =0.002, respectively). The scores of SDS and SAS had positive correlation ( Z =0.392, P =0.008). The VAS score of nasal obstruction was 6.0±3.2. The rhinomanometry in inspiratory and expiratory phase were (0.202±0.140) kPa·S/cm 3 and (0.230±0.161) kPa·S/cm 3 . Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS ( Z =0.332, P =0.045), the psychological scores, including SCL-90 score, depression, anxiety factors score, SAS and SDS, had no correlation with VAS scores and rhinomanometry ( r value was -0.030, -0.052, -0.026, 0.107, 0.185, 0.066, 0.160, 0.203, respectively, all P >0.05). Conclusions: High prevalence of depression and anxiety is found in patients with deviation of nasal septum. The SCL-90 score is consistent with SDS and SAS. Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS, the psychological scores (SCL-90 score, depression, anxiety factors score, SAS and SDS) have no correlation with VAS score and rhinomanometry.
Optimism predicts positive health in repatriated prisoners of war.
Segovia, Francine; Moore, Jeffrey L; Linnville, Steven E; Hoyt, Robert E
2015-05-01
"Positive health," defined as a state beyond the mere absence of disease, was used as a model to examine factors for enhancing health despite extreme trauma. The study examined the United States' longest detained American prisoners of war, those held in Vietnam in the 1960s through early 1970s. Positive health was measured using a physical and a psychological composite score for each individual, based on 9 physical and 9 psychological variables. Physical and psychological health was correlated with optimism obtained postrepatriation (circa 1973). Linear regressions were employed to determine which variables contributed most to health ratings. Optimism was the strongest predictor of physical health (β = -.33, t = -2.73, p = .008), followed by fewer sleep complaints (β = -.29, t = -2.52, p = .01). This model accounted for 25% of the variance. Optimism was also the strongest predictor of psychological health (β = -.41, t = -2.87, p = .006), followed by Minnesota Multiphasic Personality Inventory-Psychopathic Deviate (MMPI-PD; McKinley & Hathaway, 1944) scores (β = -.23, t = -1.88, p = .07). This model strongly suggests that optimism is a significant predictor of positive physical and psychological health, and optimism also provides long-term protective benefits. These findings and the utility of this model suggest a promising area for future research and intervention. (c) 2015 APA, all rights reserved).
Kanazawa, Yuki; Ehara, Masahiro; Sommerfeld, Thomas
2016-03-10
Low-lying π* resonance states of DNA and RNA bases have been investigated by the recently developed projected complex absorbing potential (CAP)/symmetry-adapted cluster-configuration interaction (SAC-CI) method using a smooth Voronoi potential as CAP. In spite of the challenging CAP applications to higher resonance states of molecules of this size, the present calculations reproduce resonance positions observed by electron transmission spectra (ETS) provided the anticipated deviations due to vibronic effects and limited basis sets are taken into account. Moreover, for the standard nucleobases, the calculated positions and widths qualitatively agree with those obtained in previous electron scattering calculations. For guanine, both keto and enol forms were examined, and the calculated values of the keto form agree clearly better with the experimental findings. In addition to these standard bases, three modified forms of cytosine, which serve as epigenetic or biomarkers, were investigated: formylcytosine, methylcytosine, and chlorocytosine. Last, a strong correlation between the computed positions and the observed ETS values is demonstrated, clearly suggesting that the present computational protocol should be useful for predicting the π* resonances of congeners of DNA and RNA bases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Udrescu, Corina; Mornex, Francoise, E-mail: francoise.mornex@chu-lyon.fr; Tanguy, Ronan
2013-01-01
Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SVmore » before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.« less
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
...The Coast Guard has issued a temporary deviation from the operating schedule that governs the draw of the US 17/George P. Coleman Memorial Swing Bridge across the York River, at mile 7.0, between Gloucester Point and Yorktown, VA. This deviation is necessary to facilitate maintenance on the George P. Coleman Memorial Swing Bridge. This temporary deviation allows the drawbridge to remain in the closed- to-navigation position on specific dates and times.
NASA Technical Reports Server (NTRS)
Orr, H. D., III; Campbell, S. A.
1975-01-01
A computer program was used to simulate the response of the Gas Filter Correlation Radiometer (GFCR) to changing pollutant levels of CO, SO2, CH4, and NH3 in two model atmospheres. Positive and negative deviations of tau sub alpha of magnitudes 0.01, 0.1, and 1 percent were imposed upon the simulation and the resulting deviations in inferred concentrations were determined. For the CO, CH4, and the higher pressure cell of the NH3 channel, the deviations are less than + or - 12 percent for deviations in tau sub alpha of + or - 0.1 percent, but increase to significantly higher values for larger deviations. For the lower pressure cell of NH3 and for SO2, the deviations in inferred concentration begin to rise sharply between 0.01 and 0.1 percent deviation in tau sub alpha, suggesting that a tighter control on tau sub alpha may be required for these channels.
Preliminary results from the White Sands Missile Range sonic boom propagation experiment
NASA Technical Reports Server (NTRS)
Willshire, William L., Jr.; Devilbiss, David W.
1992-01-01
Sonic boom bow shock amplitude and rise time statistics from a recent sonic boom propagation experiment are presented. Distributions of bow shock overpressure and rise time measured under different atmospheric turbulence conditions for the same test aircraft are quite different. The peak overpressure distributions are skewed positively, indicating a tendency for positive deviations from the mean to be larger than negative deviations. Standard deviations of overpressure distributions measured under moderate turbulence were 40 percent larger than those measured under low turbulence. As turbulence increased, the difference between the median and the mean increased, indicating increased positive overpressure deviations. The effect of turbulence was more readily seen in the rise time distributions. Under moderate turbulence conditions, the rise time distribution means were larger by a factor of 4 and the standard deviations were larger by a factor of 3 from the low turbulence values. These distribution changes resulted in a transition from a peaked appearance of the rise time distribution for the morning to a flattened appearance for the afternoon rise time distributions. The sonic boom propagation experiment consisted of flying three types of aircraft supersonically over a ground-based microphone array with concurrent measurements of turbulence and other meteorological data. The test aircraft were a T-38, an F-15, and an F-111, and they were flown at speeds of Mach 1.2 to 1.3, 30,000 feet above a 16 element, linear microphone array with an inter-element spacing of 200 ft. In two weeks of testing, 57 supersonic passes of the test aircraft were flown from early morning to late afternoon.
Neutral biogeography and the evolution of climatic niches.
Boucher, Florian C; Thuiller, Wilfried; Davies, T Jonathan; Lavergne, Sébastien
2014-05-01
Recent debate on whether climatic niches are conserved through time has focused on how phylogenetic niche conservatism can be measured by deviations from a Brownian motion model of evolutionary change. However, there has been no evaluation of this methodological approach. In particular, the fact that climatic niches are usually obtained from distribution data and are thus heavily influenced by biogeographic factors has largely been overlooked. Our main objective here was to test whether patterns of climatic niche evolution that are frequently observed might arise from neutral dynamics rather than from adaptive scenarios. We developed a model inspired by neutral biodiversity theory, where individuals disperse, compete, and undergo speciation independently of climate. We then sampled the climatic niches of species according to their geographic position and showed that even when species evolve independently of climate, their niches can nonetheless exhibit evolutionary patterns strongly differing from Brownian motion. Indeed, climatic niche evolution is better captured by a model of punctuated evolution with constraints due to landscape boundaries, two features that are traditionally interpreted as evidence for selective processes acting on the niche. We therefore suggest that deviation from Brownian motion alone should not be used as evidence for phylogenetic niche conservatism but that information on phenotypic traits directly linked to physiology is required to demonstrate that climatic niches have been conserved through time.
NASA Astrophysics Data System (ADS)
Robinson, Timothy; Giltrap, Samuel; Eardley, Samuel; Consoli, Fabrizio; De Angelis, Riccardo; Ingenito, Francesco; Stuart, Nicholas; Verona, Claudio; Smith, Roland A.
2018-01-01
We present an analysis of strong laser-driven electromagnetic pulses using novel electro-optic diagnostic techniques. A range of targets were considered, including thin plastic foils (20-550 nm) and mass-limited, optically-levitated micro-targets. Results from foils indicate a dependence of EMP on target thickness, with larger peak electric fields observed with thinner targets. Spectral analysis suggests high repeatability between shots, with identified spectral features consistently detected with <1 MHz standard deviations of the peak position. This deviation is reduced for shots taken on the same day, suggesting that local conditions, such as movement of metal objects within the target chamber, are more likely to lead to minor spectral modifications, highlighting the role of the local environment in determining the details of EMP production. Levitated targets are electrically isolated from their environment, hence these targets should be unable to draw a neutralization current from the earth following ejection of hot electrons from the plasma, in contrast to predictions for pin-mounted foils in the Poyé EMP generation model. With levitated targets, no EMP was measurable above the noise threshold of any diagnostic, despite observation of protons accelerated to >30 MeV energies, suggesting the discharge current contribution to EMP is dominant.
Phylogenomic analyses of malaria parasites and evolution of their exported proteins
2011-01-01
Background Plasmodium falciparum is the most malignant agent of human malaria. It belongs to the taxon Laverania, which includes other ape-infecting Plasmodium species. The origin of the Laverania is still debated. P. falciparum exports pathogenicity-related proteins into the host cell using the Plasmodium export element (PEXEL). Predictions based on the presence of a PEXEL motif suggest that more than 300 proteins are exported by P. falciparum, while there are many fewer exported proteins in non-Laverania. Results A whole-genome approach was applied to resolve the phylogeny of eight Plasmodium species and four outgroup taxa. By using 218 orthologous proteins we received unanimous support for a sister group position of Laverania and avian malaria parasites. This observation was corroborated by the analyses of 28 exported proteins with orthologs present in all Plasmodium species. Most interestingly, several deviations from the P. falciparum PEXEL motif were found to be present in the orthologous sequences of non-Laverania. Conclusion Our phylogenomic analyses strongly support the hypotheses that the Laverania have been founded by a single Plasmodium species switching from birds to African great apes or vice versa. The deviations from the canonical PEXEL motif in orthologs may explain the comparably low number of exported proteins that have been predicted in non-Laverania. PMID:21676252
Neutral biogeography and the evolution of climatic niches
Boucher, Florian C.; Thuiller, Wilfried; Davies, T. Jonathan; Lavergne, Sébastien
2014-01-01
Recent debate on whether climatic niches are conserved through time has focused on how phylogenetic niche conservatism can be measured by deviations from a Brownian motion model of evolutionary change. However, there has been no evaluation of this methodological approach. In particular, the fact that climatic niches are usually obtained from distribution data and are thus heavily influenced by biogeographic factors has largely been overlooked. Our main objective here was to test whether patterns of climatic niche evolution that are frequently observed might arise from neutral dynamics rather than adaptive scenarios. We develop a model inspired by Neutral Biodiversity Theory, where individuals disperse, compete, and undergo speciation independently of climate. We then sample the climatic niches of species according to their geographic position and show that even when species evolved independently of climate, their niches can nonetheless exhibit evolutionary patterns strongly differing from Brownian motion. Indeed, climatic niche evolution is better captured by a model of punctuated evolution with constraints due to landscape boundaries, two features that are traditionally interpreted as evidence for selective processes acting on the niche. We therefore suggest that deviation from Brownian motion alone should not be used as evidence for phylogenetic niche conservatism, but that information on phenotypic traits directly linked to physiology is required to demonstrate that climatic niches have been conserved through time. PMID:24739191
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mun, Eundeok; Bud'ko, Sergey L.; Canfield, Paul C.
We present the magnetic field dependencies of transport properties for RPtBi ( R = Gd, Dy, Tm, and Lu) half-Heusler compounds. Temperature- and field-dependent resistivity measurements of high-quality RPtBi single crystals reveal an unusually large, nonsaturating magnetoresistance (MR) up to 300 K under a moderate magnetic field of H = 140 kOe. At 300 K, the large MR effect decreases as the rare earth is traversed from Gd to Lu and the magnetic field dependence of MR shows a deviation from the conventional H2 behavior. The Hall coefficient ( RH) for R = Gd indicates a sign change around 120more » K, whereas RH curves for R = Dy, Tm, and Lu remain positive for all measured temperatures. At 300 K, the Hall resistivity reveals a deviation from the linear field dependence for all compounds. Thermoelectric power measurements on this family show strong temperature and magnetic field dependencies which are consistent with resistivity measurements. A highly enhanced thermoelectric power under applied magnetic field is observed as high as ~100 μV/K at 140 kOe. Furthermore, analysis of the transport data in this series reveals that the rare-earth-based half-Heusler compounds provide opportunities to tune MR effect through lanthanide contraction and to elucidate the mechanism of nontrivial MR.« less
Is there a link between cognitive abilities and environmental awareness? Cross-national evidence.
Salahodjaev, Raufhon
2018-06-05
This article explores the effect of cognitive abilities on environmental awareness using data from 119 countries for the period 2005-2015. Our findings provide pioneering confirmation that a facet of human psychology, namely cognitive ability, is positively associated with environmentalism. The empirical estimations indicate that when cognitive abilities increase by one standard deviation, climate change awareness increases by approximately 19% (slightly less than one standard deviation). This positive association remains intact when we control for other determinants of environmentalism. Copyright © 2018 Elsevier Inc. All rights reserved.
2010-01-01
Background Previous research has shown that underlying dietary patterns are related to the risk of many different adverse health outcomes, but the relationship of these underlying patterns to skeletal fragility is not well understood. The objective of the study was to determine whether dietary patterns in men (ages 25-49, 50+) and women (pre-menopause, post-menopause) are related to femoral neck bone mineral density (BMD) independently of other lifestyle variables, and whether this relationship is mediated by body mass index. Methods We performed an analysis of 1928 men and 4611 women participants in the Canadian Multicentre Osteoporosis Study, a randomly selected population-based longitudinal cohort. We determined dietary patterns based on the self-administered food frequency questionnaires in year 2 of the study (1997-99). Our primary outcome was BMD as measured by dual x-ray absorptiometry in year 5 of the study (2000-02). Results We identified two underlying dietary patterns using factor analysis and then derived factor scores. The first factor (nutrient dense) was most strongly associated with intake of fruits, vegetables, and whole grains. The second factor (energy dense) was most strongly associated with intake of soft drinks, potato chips and French fries, certain meats (hamburger, hot dog, lunch meat, bacon, and sausage), and certain desserts (doughnuts, chocolate, ice cream). The energy dense factor was associated with higher body mass index independent of other demographic and lifestyle factors, and body mass index was a strong independent predictor of BMD. Surprisingly, we did not find a similar positive association between diet and BMD. In fact, when adjusted for body mass index, each standard deviation increase in the energy dense score was associated with a BMD decrease of 0.009 (95% CI: 0.002, 0.016) g/cm2 for men 50+ years old and 0.004 (95% CI: 0.000, 0.008) g/cm2 for postmenopausal women. In contrast, for men 25-49 years old, each standard deviation increase in the nutrient dense score, adjusted for body mass index, was associated with a BMD increase of 0.012 (95% CI: 0.002, 0.022) g/cm2. Conclusions In summary, we found no consistent relationship between diet and BMD despite finding a positive association between a diet high in energy dense foods and higher body mass index and a strong correlation between body mass index and BMD. Our data suggest that some factor related to the energy dense dietary pattern may partially offset the advantages of higher body mass index with regard to bone health. PMID:20109205
A hybrid method with deviational particles for spatial inhomogeneous plasma
NASA Astrophysics Data System (ADS)
Yan, Bokai
2016-03-01
In this work we propose a Hybrid method with Deviational Particles (HDP) for a plasma modeled by the inhomogeneous Vlasov-Poisson-Landau system. We split the distribution into a Maxwellian part evolved by a grid based fluid solver and a deviation part simulated by numerical particles. These particles, named deviational particles, could be both positive and negative. We combine the Monte Carlo method proposed in [31], a Particle in Cell method and a Macro-Micro decomposition method [3] to design an efficient hybrid method. Furthermore, coarse particles are employed to accelerate the simulation. A particle resampling technique on both deviational particles and coarse particles is also investigated and improved. This method is applicable in all regimes and significantly more efficient compared to a PIC-DSMC method near the fluid regime.
VanTieghem, Michelle R.; Gabard-Durnam, Laurel; Goff, Bonnie; Flannery, Jessica; Humphreys, Kathryn L.; Telzer, Eva H.; Caldera, Christina; Louie, Jennifer Y.; Shapiro, Mor; Bolger, Niall; Tottenham, Nim
2018-01-01
Institutional caregiving is associated with significant deviations from species-expected caregiving, altering the normative sequence of attachment formation and placing children at risk for long-term emotional difficulties. However, little is known about factors that can promote resilience following early institutional caregiving. In the current study, we investigated how adaptations in affective processing (i.e. positive valence bias) and family-level protective factors (i.e. secure parent-child relationships) moderate risk for internalizing symptoms in Previously Institutionalized (PI) youth. Children and adolescents with and without a history of institutional care performed a laboratory-based affective processing task and self-reported measures of parent-child relationship security. PI youth were more likely than comparison youth to show positive valence biases when interpreting ambiguous facial expressions. Both positive valence bias and parent-child relationship security moderated the association between institutional care and parent-reported internalizing symptoms, such that greater positive valence bias and more secure parent-child relationships predicted fewer symptoms in PI youth. However, when both factors were tested concurrently, parent-child relationship security more strongly moderated the link between PI status and internalizing symptoms. These findings suggest that both individual-level adaptations in affective processing and family-level factors of secure parent-child relationships may ameliorate risk for internalizing psychopathology following early institutional caregiving. PMID:28401841
Vantieghem, Michelle R; Gabard-Durnam, Laurel; Goff, Bonnie; Flannery, Jessica; Humphreys, Kathryn L; Telzer, Eva H; Caldera, Christina; Louie, Jennifer Y; Shapiro, Mor; Bolger, Niall; Tottenham, Nim
2017-05-01
Institutional caregiving is associated with significant deviations from species-expected caregiving, altering the normative sequence of attachment formation and placing children at risk for long-term emotional difficulties. However, little is known about factors that can promote resilience following early institutional caregiving. In the current study, we investigated how adaptations in affective processing (i.e., positive valence bias) and family-level protective factors (i.e., secure parent-child relationships) moderate risk for internalizing symptoms in previously institutionalized (PI) youth. Children and adolescents with and without a history of institutional care performed a laboratory-based affective processing task and self-reported measures of parent-child relationship security. PI youth were more likely than comparison youth to show positive valence biases when interpreting ambiguous facial expressions. Both positive valence bias and parent-child relationship security moderated the association between institutional care and parent-reported internalizing symptoms, such that greater positive valence bias and more secure parent-child relationships predicted fewer symptoms in PI youth. However, when both factors were tested concurrently, parent-child relationship security more strongly moderated the link between PI status and internalizing symptoms. These findings suggest that both individual-level adaptations in affective processing and family-level factors of secure parent-child relationships may ameliorate risk for internalizing psychopathology following early institutional caregiving.
Electron–hole asymmetry of the topological surface states in strained HgTe
Jost, Andreas; Bendias, Michel; Böttcher, Jan; Hankiewicz, Ewelina; Brüne, Christoph; Buhmann, Hartmut; Molenkamp, Laurens W.; Maan, Jan C.; Zeitler, Uli; Hussey, Nigel; Wiedmann, Steffen
2017-01-01
Topological insulators are a new class of materials with an insulating bulk and topologically protected metallic surface states. Although it is widely assumed that these surface states display a Dirac-type dispersion that is symmetric above and below the Dirac point, this exact equivalence across the Fermi level has yet to be established experimentally. Here, we present a detailed transport study of the 3D topological insulator-strained HgTe that strongly challenges this prevailing viewpoint. First, we establish the existence of exclusively surface-dominated transport via the observation of an ambipolar surface quantum Hall effect and quantum oscillations in the Seebeck and Nernst effect. Second, we show that, whereas the thermopower is diffusion driven for surface electrons, both diffusion and phonon drag contributions are essential for the hole surface carriers. This distinct behavior in the thermoelectric response is explained by a strong deviation from the linear dispersion relation for the surface states, with a much flatter dispersion for holes compared with electrons. These findings show that the metallic surface states in topological insulators can exhibit both strong electron–hole asymmetry and a strong deviation from a linear dispersion but remain topologically protected. PMID:28280101
Modeling failure in brittle porous ceramics
NASA Astrophysics Data System (ADS)
Keles, Ozgur
Brittle porous materials (BPMs) are used for battery, fuel cell, catalyst, membrane, filter, bone graft, and pharmacy applications due to the multi-functionality of their underlying porosity. However, in spite of its technological benefits the effects of porosity on BPM fracture strength and Weibull statistics are not fully understood--limiting a wider use. In this context, classical fracture mechanics was combined with two-dimensional finite element simulations not only to account for pore-pore stress interactions, but also to numerically quantify the relationship between the local pore volume fraction and fracture statistics. Simulations show that even the microstructures with the same porosity level and size of pores differ substantially in fracture strength. The maximum reliability of BPMs was shown to be limited by the underlying pore--pore interactions. Fracture strength of BMPs decreases at a faster rate under biaxial loading than under uniaxial loading. Three different types of deviation from classic Weibull behavior are identified: P-type corresponding to a positive lower tail deviation, N-type corresponding to a negative lower tail deviation, and S-type corresponding to both positive upper and lower tail deviations. Pore-pore interactions result in either P-type or N-type deviation in the limit of low porosity, whereas S-type behavior occurs when clusters of low and high fracture strengths coexist in a fracture data.
Single-Station Sigma for the Iranian Strong Motion Stations
NASA Astrophysics Data System (ADS)
Zafarani, H.; Soghrat, M. R.
2017-11-01
In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.
77 FR 41685 - Drawbridge Operation Regulation; Willamette River, Portland, OR
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-16
... deviation is necessary to accommodate Portland's Big Float event. This deviation allows the bridge to remain... of the Big Float event. The Hawthorne Bridge crosses the Willamette River at mile 13.1 and provides 49 feet of vertical clearance above Columbia River Datum 0.0 while in the closed position. Vessels...
77 FR 51700 - Drawbridge Operation Regulations; Wando River, Cainhoy, SC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
... improve vessel traffic flow. DATES: This deviation is effective from 8 p.m. on September 1, 2012 through 5... positive impact on navigation with the increased use of the waterway by vessel traffic. This deviation is... test on local marine traffic. The Coast Guard will also consider all comments and related materials...
Underwater EIT Follow-on Project
2009-01-01
correlation value of 0.2. (White pixels indicate zero deviation from predicted transimpedance ; blue represents high deviation...34 Figure 50. Sample transimpedance measurements for high turbidity (top) and low turbidity (bottom) conditions. (These measurements...magnitudes of the transimpedance measurements. ... 40 Figure 67. A reconstruction image of rust level 0. The true target position is 2cm below the
76 FR 26606 - Drawbridge Operation Regulation; Neches River, Beaumont, TX
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-09
... deviation from the regulation governing the operation of the KCS vertical lift span bridge across the Neches... Southern Railroad has requested a temporary deviation from the operating schedule of the vertical lift span... in the open-to-navigation position. In accordance with 33 CFR 117.971, the vertical lift span of the...
76 FR 49662 - Drawbridge Operation Regulation; Grassy Sound Channel, Middle Township, NJ
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-11
... accommodate racers in ``The Wild Half'' half marathon. This deviation allows the bridge to remain in the closed position to ensure safe passage for the half marathon racers. DATES: This deviation is effective... Sound Channel, mile 1.0, at Middle Township, NJ. The route of ``The Wild Half'' half marathon crosses...
Emotional stimulation alters olfactory sensitivity and odor judgment.
Pollatos, Olga; Kopietz, Rainer; Linn, Jennifer; Albrecht, Jessica; Sakar, Vehbi; Anzinger, Andrea; Schandry, Rainer; Wiesmann, Martin
2007-07-01
Emotions have a strong influence on the perception of visual and auditory stimuli. Only little is known about the relation between emotional stimulation and olfactory functions. The present study investigated the relationship between the presentation of affective pictures, olfactory functions, and sex. Olfactory performance was assessed in 32 subjects (16 male). Olfactory sensitivity was significantly reduced following unpleasant picture presentation for all subjects and following pleasant picture presentation for male subjects only. Pleasantness and intensity ratings of a neutral suprathreshold odor were related to the valence of the pictures: After unpleasant picture presentation, the odor was rated as less pleasant and more intense, whereas viewing positive pictures induced a significant increase in reported odor pleasantness. We conclude that inducing a negative emotional state reduces olfactory sensitivity. A relation to functional deviations within the primary olfactory cortices is discussed.
Ion transport mechanism in glasses: non-Arrhenius conductivity and nonuniversal features.
Murugavel, S; Vaid, C; Bhadram, V S; Narayana, C
2010-10-28
In this article, we report non-Arrhenius behavior in the temperature-dependent dc conductivity of alkali ion conducting silicate glasses well below their glass transition temperature. In contrast to the several fast ion-conducting and binary potassium silicate glasses, these glasses show a positive deviation in the Arrhenius plot. The observed non-Arrhenius behavior is completely reproducible in nature even after prolonged annealing close to the glass transition temperature of the respective glass sample. These results are the manifestation of local structural changes of the silicate network with temperature and give rise to different local environments into which the alkali ions hop, revealed by in situ high-temperature Raman spectroscopy. Furthermore, the present study provides new insights into the strong link between the dynamics of the alkali ions and different sites associated with it in the glasses.
Data on diverse roles of helix perturbations in membrane proteins.
Shelar, Ashish; Bansal, Manju
2016-12-01
The various structural variations observed in TM helices of membrane proteins have been deconstructed into 9 distinct types of helix perturbations. These perturbations are defined by the deviation of TM helices from the predominantly observed linear α-helical conformation, to form 3 10 - and π-helices, as well as adopting curved and kinked geometries. The data presented here supplements the article 'Helix perturbations in Membrane Proteins Assist in Inter-helical Interactions and Optimal Helix Positioning in the Bilayer' (A. Shelar, M. Bansal, 2016) [1]. This data provides strong evidence for the role of various helix perturbations in influencing backbone torsion angles of helices, mediating inter-helical interactions, oligomer formation and accommodation of hydrophobic residues within the bilayer. The methodology used for creation of various datasets of membrane protein families (Sodium/Calcium exchanger and Heme Copper Oxidase) has also been mentioned.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin, Jie; Department of Automation, Nanjing Polytechnic Institute, 210048 Nanjing; Tao, Chao, E-mail: taochao@nju.edu.cn
2015-06-08
Acoustically inhomogeneous mediums with multiple scattering are often the nightmare of photoacoustic tomography. In order to break this limitation, a photoacoustic tomography scheme combining ultrasound interferometry and time reversal is proposed to achieve images in acoustically scattering medium. An ultrasound interferometry is developed to determine the unknown Green's function of strong scattering tissue. Using the determined Greens' function, a time-reversal process is carried out to restore images behind an acoustically inhomogeneous layer from the scattering photoacoustic signals. This method effectively decreases the false contrast, noise, and position deviation of images induced by the multiple scattering. Phantom experiment is carried outmore » to validate the method. Therefore, the proposed method could have potential value in extending the biomedical applications of photoacoustic tomography in acoustically inhomogeneous tissue.« less
Gait analysis in children with cerebral palsy.
Armand, Stéphane; Decoulon, Geraldo; Bonnefoy-Mazure, Alice
2016-12-01
Cerebral palsy (CP) children present complex and heterogeneous motor disorders that cause gait deviations.Clinical gait analysis (CGA) is needed to identify, understand and support the management of gait deviations in CP. CGA assesses a large amount of quantitative data concerning patients' gait characteristics, such as video, kinematics, kinetics, electromyography and plantar pressure data.Common gait deviations in CP can be grouped into the gait patterns of spastic hemiplegia (drop foot, equinus with different knee positions) and spastic diplegia (true equinus, jump, apparent equinus and crouch) to facilitate communication. However, gait deviations in CP tend to be a continuum of deviations rather than well delineated groups. To interpret CGA, it is necessary to link gait deviations to clinical impairments and to distinguish primary gait deviations from compensatory strategies.CGA does not tell us how to treat a CP patient, but can provide objective identification of gait deviations and further the understanding of gait deviations. Numerous treatment options are available to manage gait deviations in CP. Generally, treatments strive to limit secondary deformations, re-establish the lever arm function and preserve muscle strength.Additional roles of CGA are to better understand the effects of treatments on gait deviations. Cite this article: Armand S, Decoulon G, Bonnefoy-Mazure A. Gait analysis in children with cerebral palsy. EFORT Open Rev 2016;1:448-460. DOI: 10.1302/2058-5241.1.000052.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Roeck, W., E-mail: wojciech.deroeck@fys.kuleuven.be, E-mail: christian.maes@fys.kuleuven.be, E-mail: netocny@fzu.cz, E-mail: marius.schutz@fys.kuleuven.be; Maes, C., E-mail: wojciech.deroeck@fys.kuleuven.be, E-mail: christian.maes@fys.kuleuven.be, E-mail: netocny@fzu.cz, E-mail: marius.schutz@fys.kuleuven.be; Schütz, M., E-mail: wojciech.deroeck@fys.kuleuven.be, E-mail: christian.maes@fys.kuleuven.be, E-mail: netocny@fzu.cz, E-mail: marius.schutz@fys.kuleuven.be
2015-02-15
We study the projection on classical spins starting from quantum equilibria. We show Gibbsianness or quasi-locality of the resulting classical spin system for a class of gapped quantum systems at low temperatures including quantum ground states. A consequence of Gibbsianness is the validity of a large deviation principle in the quantum system which is known and here recovered in regimes of high temperature or for thermal states in one dimension. On the other hand, we give an example of a quantum ground state with strong nonlocality in the classical restriction, giving rise to what we call measurement induced entanglement andmore » still satisfying a large deviation principle.« less
NASA Astrophysics Data System (ADS)
van der Maas, M.; Vasnyov, S.; Hendriksen, B. L. M.; Shklyarevskii, O. I.; Speller, S.
2012-06-01
Physisorption of hydrogen molecules on the surface of gold and other coinage metals has been studied using distance tunneling spectroscopy. We have observed that the distance dependence of the tunnel current (resistance) displays a strong N-shaped deviation from exponential behavior. Such deviations are difficult to explain within the Tersoff-Hamann approximation. We suggest the scattering of tunneling electrons by H2 molecules as an origin for the observed effect. We have found that this phenomenon is also common for strongly adsorbed organic molecules with a single anchoring group. Pulling Au, Cu and Pt nanowires at 22 K in hydrogen environment shows that the break-junction electrodes are still connected through hydrogen-metal monoatomic chains down to very low conductance values of 10-4-10-6 G0.
Bound and resonance states of positronic copper atoms
NASA Astrophysics Data System (ADS)
Yamashita, Takuma; Umair, Muhammad; Kino, Yasushi
2017-10-01
We report a theoretical calculation for the bound and S-wave resonance states of the positronic copper atom (e+Cu). A positron is a positively charged particle; therefore, a positronic atom has an attractive correlation between the positron and electron. A Gaussian expansion method is adopted to directly describe this correlation as well as the strong repulsive interaction with the nucleus. The correlation between the positron and electron is much more important than that between electrons in an analogous system of Cu-, although the formation of a positronium (Ps) in e+Cu is not expressed in the ground state structure explicitly. Resonance states are calculated with a complex scaling method and identified above the first excited state of the copper atom. Resonance states below Ps (n = 2) + Cu+ classified to a dipole series show agreement with a simple analytical law. Comparison of the resonance energies and widths of e+Cu with those of e+K, of which the potential energy of the host atom resembles that of e+Cu, reveals that the positions of the resonance for the e+Cu dipole series deviate equally from those of e+K.
Cognitive ability and the demand for redistribution.
Mollerstrom, Johanna; Seim, David
2014-01-01
Empirical research suggests that the cognitively able are politically more influential than the less able, by being more likely to vote and to assume leadership positions. This study asks whether this pattern matters for public policy by investigating what role a person's cognitive ability plays in determining his preferences for redistribution of income among citizens in society. To answer this question, we use a unique Swedish data set that matches responses to a tailor-made questionnaire to administrative tax records and to military enlistment records for men, with the latter containing a measure of cognitive ability. On a scale of 0 to 100 percent redistribution, a one-standard-deviation increase in cognitive ability reduces the willingness to redistribute by 5 percentage points, or by the same amount as a $35,000 increase in mean annual income. We find support for two channels mediating this economically strong and statistically significant relation. First, higher ability is associated with higher income. Second, ability is positively correlated with the view that economic success is the result of effort, rather than luck. Both these factors are, in turn, related to lower demand for redistribution.
Cognitive Ability and the Demand for Redistribution
Mollerstrom, Johanna; Seim, David
2014-01-01
Empirical research suggests that the cognitively able are politically more influential than the less able, by being more likely to vote and to assume leadership positions. This study asks whether this pattern matters for public policy by investigating what role a person's cognitive ability plays in determining his preferences for redistribution of income among citizens in society. To answer this question, we use a unique Swedish data set that matches responses to a tailor-made questionnaire to administrative tax records and to military enlistment records for men, with the latter containing a measure of cognitive ability. On a scale of 0 to 100 percent redistribution, a one-standard-deviation increase in cognitive ability reduces the willingness to redistribute by 5 percentage points, or by the same amount as a $35,000 increase in mean annual income. We find support for two channels mediating this economically strong and statistically significant relation. First, higher ability is associated with higher income. Second, ability is positively correlated with the view that economic success is the result of effort, rather than luck. Both these factors are, in turn, related to lower demand for redistribution. PMID:25343713
78 FR 39591 - Drawbridge Operation Regulation; Lake Washington Ship Canal at Seattle, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
...The Coast Guard has issued a temporary deviation from the operating schedule that governs three Seattle Department of Transportation (SDOT) bridges: The Ballard Bridge, mile 1.1, the Fremont Bridge, mile 2.6, and the University Bridge, mile 4.3, all crossing the Lake Washington Ship Canal at Seattle, WA. The deviation is necessary to accommodate heavier than normal roadway traffic associated with a fireworks display over Lake Union. This deviation allows the bridges to remain in the closed position immediately prior to until immediately after the fireworks display.
Visuomotor adaptation needs a validation of prediction error by feedback error
Gaveau, Valérie; Prablanc, Claude; Laurent, Damien; Rossetti, Yves; Priot, Anne-Emmanuelle
2014-01-01
The processes underlying short-term plasticity induced by visuomotor adaptation to a shifted visual field are still debated. Two main sources of error can induce motor adaptation: reaching feedback errors, which correspond to visually perceived discrepancies between hand and target positions, and errors between predicted and actual visual reafferences of the moving hand. These two sources of error are closely intertwined and difficult to disentangle, as both the target and the reaching limb are simultaneously visible. Accordingly, the goal of the present study was to clarify the relative contributions of these two types of errors during a pointing task under prism-displaced vision. In “terminal feedback error” condition, viewing of their hand by subjects was allowed only at movement end, simultaneously with viewing of the target. In “movement prediction error” condition, viewing of the hand was limited to movement duration, in the absence of any visual target, and error signals arose solely from comparisons between predicted and actual reafferences of the hand. In order to prevent intentional corrections of errors, a subthreshold, progressive stepwise increase in prism deviation was used, so that subjects remained unaware of the visual deviation applied in both conditions. An adaptive aftereffect was observed in the “terminal feedback error” condition only. As far as subjects remained unaware of the optical deviation and self-assigned pointing errors, prediction error alone was insufficient to induce adaptation. These results indicate a critical role of hand-to-target feedback error signals in visuomotor adaptation; consistent with recent neurophysiological findings, they suggest that a combination of feedback and prediction error signals is necessary for eliciting aftereffects. They also suggest that feedback error updates the prediction of reafferences when a visual perturbation is introduced gradually and cognitive factors are eliminated or strongly attenuated. PMID:25408644
NASA Astrophysics Data System (ADS)
Yu, Tao; Zuo, Xiaomin; Xia, Chunliang; Li, Mingyuan; Huang, Cong; Mao, Tian; Zhang, Xiaoxin; Zhao, Biqiang; Liu, Libo
2017-04-01
A new method for estimating daily averaged peak height of the OH airglow layer from a ground-based meteor radar (MR) and a Fabry-Perot interferometer (FPI) is presented. The first results are derived from 4 year simultaneous measurements of winds by a MR and a FPI at two adjacent stations over center China and are compared with observations from the Thermosphere Ionosphere Mesosphere Energetics and Dynamics/Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) instrument. The OH airglow peak heights, which are derived by using correlation analysis between winds of the FPI and MR, are found to generally peak at an altitude of 87 km and frequently varied between 80 km and 90 km day to day. In comparison with SABER OH 1.6 μm observations, reasonable similarity of airglow peak heights is found, and rapid day-to-day variations are also pronounced. Lomb-Scargle analysis is used to determine cycles of temporal variations of airglow peak heights, and there are obvious periodic variations both in our airglow peak heights and in the satellite observations. In addition to the annual, semiannual, monthly, and three monthly variations, the shorter time variations, e.g., day-to-day and several days' variations, are also conspicuous. The day-to-day variations of airglow height obviously could reduce observation accuracy and lead to some deviations in FPI measurements. These FPI wind deviations arising from airglow height variations are also estimated to be about 3-5 m/s from 2011 to 2015, with strong positive correlation with airglow peak height variation. More attention should be paid to the wind deviations associated with airglow height variation when using and interpreting winds measured by FPI.
Sticky ions in biological systems.
Collins, K D
1995-01-01
Aqueous gel sieving chromatography on Sephadex G-10 of the Group IA cations (Li+, Na+, K+, Rb+, Cs+) plus NH4+ as the Cl- salts, in combination with previous results for the halide anions (F-, Cl-, Br-, I-) as the Na+ salts [Washabaugh, M.W. & Collins, K.D. (1986) J. Biol. Chem. 261, 12477-12485], leads to the following conclusions. (i) The small monovalent ions (Li+, Na+, F-) flow through the gel with water molecules attached, whereas the large monovalent ions (K+, Rb+, Cs+, Cl-, Br-, I-) adsorb to the nonpolar surface of the gel, a process requiring partial dehydration of the ion and implying that these ions bind the immediately adjacent water molecules weakly. (ii) The transition from strong to weak hydration occurs at a radius of about 1.78 A for the monovalent anions, compared with a radius of about 1.06 A for the monovalent cations (using ionic radii), indicating that the anions are more strongly hydrated than the cations for a given charge density. (iii) The anions show larger deviations from ideal behavior (an elution position corresponding to the anhydrous molecular weight) than do the cations and dominate the chromatographic behavior of the neutral salts. These results are interpreted to mean that weakly hydrated ions (chaotropes) are "pushed" onto weakly hydrated surfaces by strong water-water interactions and that the transition from strong ionic hydration to weak ionic hydration occurs where the strength of ion-water interactions approximately equals the strength of water-water interactions in bulk solution. PMID:7539920
Fan, M; Wang, K; Jiang, D
1999-08-01
In this paper, we study the existence and global attractivity of positive periodic solutions of periodic n-species Lotka-Volterra competition systems. By using the method of coincidence degree and Lyapunov functional, a set of easily verifiable sufficient conditions are derived for the existence of at least one strictly positive (componentwise) periodic solution of periodic n-species Lotka-Volterra competition systems with several deviating arguments and the existence of a unique globally asymptotically stable periodic solution with strictly positive components of periodic n-species Lotka-Volterra competition system with several delays. Some new results are obtained. As an application, we also examine some special cases of the system we considered, which have been studied extensively in the literature. Some known results are improved and generalized.
EXACTRAC x-ray and beam isocenters-what's the difference?
Tideman Arp, Dennis; Carl, Jesper
2012-03-01
To evaluate the geometric accuracy of the isocenter of an image-guidance system, as implemented in the exactrac system from brainlab, relative to the linear accelerator radiation isocenter. Subsequently to correct the x-ray isocenter of the exactrac system for any geometric discrepancies between the two isocenters. Five Varian linear accelerators all equipped with electronic imaging devices and exactrac with robotics from brainlab were evaluated. A commercially available Winston-Lutz phantom and an in-house made adjustable base were used in the setup. The electronic portal imaging device of the linear accelerators was used to acquire MV-images at various gantry angles. Stereoscopic pairs of x-ray images were acquired using the exactrac system. The deviation between the position of the external laser isocenter and the exactrac isocenter was evaluated using the commercial software of the exactrac system. In-house produced software was used to analyze the MV-images and evaluate the deviation between the external laser isocenter and the radiation isocenter of the linear accelerator. Subsequently, the deviation between the radiation isocenter and the isocenter of the exactrac system was calculated. A new method of calibrating the isocenter of the exactrac system was applied to reduce the deviations between the radiation isocenter and the exactrac isocenter. To evaluate the geometric accuracy a 3D deviation vector was calculated for each relative isocenter position. The 3D deviation between the external laser isocenter and the isocenter of the exactrac system varied from 0.21 to 0.42 mm. The 3D deviation between the external laser isocenter and the linac radiation isocenter ranged from 0.37 to 0.83 mm. The 3D deviation between the radiation isocenter and the isocenter of the exactrac system ranged from 0.31 to 1.07 mm. Using the new method of calibrating the exactrac isocenter the 3D deviation of one linac was reduced from 0.90 to 0.23 mm. The results were complicated due to routine maintenance of the linac, including laser calibration. It was necessary to repeat the measurements in order to perform the calibration of the exactrac isocenter. The deviations between the linac radiation isocenter and the exactrac isocenter were of an order that may have clinical relevance. An alternative method of calibrating the isocenter of the exactrac system was applied and reduced the deviations between the two isocenters.
78 FR 19585 - Drawbridge Operation Regulations; China Basin, San Francisco, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... scheduled CycleSF, a community event. This deviation allows the bridge to remain in the closed-to-navigation... above Mean High Water in the closed-to-navigation position. The draw opens on signal if at least one... allow participants in the CycleSF to cross the bridge during the event. This temporary deviation has...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-09
... Charity Motorcycle Run. Under this temporary deviation the Loop Parkway Bridge may remain in the closed... operation of the Loop Parkway Bridge, mile 0.7, across Long Creek, and the Captree State Parkway (Robert... bridges listed above to remain in the closed position during this public event. DATES: This deviation is...
77 FR 40509 - Drawbridge Operation Regulation; Oakland Inner Harbor Tidal Canal, Alameda, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-10
... Agency to perform necessary repairs on the drawbridge. This deviation allows single leaf operation of the double leaf bascule style drawbridge during the project. DATES: This deviation is effective from 7 a.m... leaf of the double bascule drawspan may be secured in the closed-to-navigation position from 7 a.m...
Diode‐based transmission detector for IMRT delivery monitoring: a validation study
Li, Taoran; Wu, Q. Jackie; Matzen, Thomas; Yin, Fang‐Fang
2016-01-01
The purpose of this work was to evaluate the potential of a new transmission detector for real‐time quality assurance of dynamic‐MLC‐based radiotherapy. The accuracy of detecting dose variation and static/dynamic MLC position deviations was measured, as well as the impact of the device on the radiation field (surface dose, transmission). Measured dose variations agreed with the known variations within 0.3%. The measurement of static and dynamic MLC position deviations matched the known deviations with high accuracy (0.7–1.2 mm). The absorption of the device was minimal (∼ 1%). The increased surface dose was small (1%–9%) but, when added to existing collimator scatter effects could become significant at large field sizes (≥30×30 cm2). Overall the accuracy and speed of the device show good potential for real‐time quality assurance. PACS number(s): 87.55.Qr PMID:27685115
Intensity stabilisation of optical pulse sequences for coherent control of laser-driven qubits
NASA Astrophysics Data System (ADS)
Thom, Joseph; Yuen, Ben; Wilpers, Guido; Riis, Erling; Sinclair, Alastair G.
2018-05-01
We demonstrate a system for intensity stabilisation of optical pulse sequences used in laser-driven quantum control of trapped ions. Intensity instability is minimised by active stabilisation of the power (over a dynamic range of > 104) and position of the focused beam at the ion. The fractional Allan deviations in power were found to be <2.2 × 10^{-4} for averaging times from 1 to 16,384 s. Over similar times, the absolute Allan deviation of the beam position is <0.1 μm for a 45 {μ }m beam diameter. Using these residual power and position instabilities, we estimate the associated contributions to infidelity in example qubit logic gates to be below 10^{-6} per gate.
Statistical analysis of the 70 meter antenna surface distortions
NASA Technical Reports Server (NTRS)
Kiedron, K.; Chian, C. T.; Chuang, K. L.
1987-01-01
Statistical analysis of surface distortions of the 70 meter NASA/JPL antenna, located at Goldstone, was performed. The purpose of this analysis is to verify whether deviations due to gravity loading can be treated as quasi-random variables with normal distribution. Histograms of the RF pathlength error distribution for several antenna elevation positions were generated. The results indicate that the deviations from the ideal antenna surface are not normally distributed. The observed density distribution for all antenna elevation angles is taller and narrower than the normal density, which results in large positive values of kurtosis and a significant amount of skewness. The skewness of the distribution changes from positive to negative as the antenna elevation changes from zenith to horizon.
Global positioning system measurements for crustal deformation: Precision and accuracy
Prescott, W.H.; Davis, J.L.; Svarc, J.L.
1989-01-01
Analysis of 27 repeated observations of Global Positioning System (GPS) position-difference vectors, up to 11 kilometers in length, indicates that the standard deviation of the measurements is 4 millimeters for the north component, 6 millimeters for the east component, and 10 to 20 millimeters for the vertical component. The uncertainty grows slowly with increasing vector length. At 225 kilometers, the standard deviation of the measurement is 6, 11, and 40 millimeters for the north, east, and up components, respectively. Measurements with GPS and Geodolite, an electromagnetic distance-measuring system, over distances of 10 to 40 kilometers agree within 0.2 part per million. Measurements with GPS and very long baseline interferometry of the 225-kilometer vector agree within 0.05 part per million.
NASA Astrophysics Data System (ADS)
Fang, Yuanyuan; Fiore, Arlene M.; Horowitz, Larry W.; Gnanadesikan, Anand; Levy, Hiram; Hu, Yongtao; Russell, Armistead G.
2009-12-01
While the export of pollutants from the United States exhibits notable variability from day to day and is often considered to be "episodic," the contribution of strong daily export events to total export has not been quantified. We use carbon monoxide (CO) as a tracer of anthropogenic pollutants in the Model of OZone And Related Tracers (MOZART) to estimate this contribution. We first identify the major export pathway from the United States to be through the northeast boundary (24-48°N along 67.5°W and 80-67.5°W along 48°N), and then analyze 15 summers of daily CO export fluxes through this boundary. These daily CO export fluxes have a nearly Gaussian distribution with a mean of 1100 Gg CO day-1 and a standard deviation of 490 Gg CO day-1. To focus on the synoptic variability, we define a "synoptic background" export flux equal to the 15 day moving average export flux and classify strong export days according to their fluxes relative to this background. As expected from Gaussian statistics, 16% of summer days are "strong export days," classified as those days when the CO export flux exceeds the synoptic background by one standard deviation or more. Strong export days contributes 25% to the total export, a value determined by the relative standard deviation of the CO flux distribution. Regressing the anomalies of the CO export flux through the northeast U.S. boundary relative to the synoptic background on the daily anomalies in the surface pressure field (also relative to a 15 day running mean) suggests that strong daily export fluxes are correlated with passages of midlatitude cyclones over the Gulf of Saint Lawrence. The associated cyclonic circulation and Warm Conveyor Belts (WCBs) that lift surface pollutants over the northeastern United States have been shown previously to be associated with long-range transport events. Comparison with observations from the 2004 INTEX-NA field campaign confirms that our model captures the observed enhancements in CO outflow and resolves the processes associated with cyclone passages on strong export days. "Moderate export days," defined as days when the CO flux through the northeast boundary exceeds the 15 day running mean by less than one standard deviation, represent an additional 34% of summer days and 40% of total export. These days are also associated with migratory midlatitude cyclones. The remaining 35% of total export occurs on "weak export days" (50% of summer days) when high pressure anomalies occur over the Gulf of Saint Lawrence. Our findings for summer also apply to spring, when the U.S. pollutant export is typically strongest, with similar contributions to total export and associated meteorology on strong, moderate and weak export days. Although cyclone passages are the primary driver for strong daily export events, export during days without cyclone passages also makes a considerable contribution to the total export and thereby to the global pollutant budget.
Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler
NASA Astrophysics Data System (ADS)
Liu, Jinglong; Zhao, Xianqiao; Hou, Fanjun; Wu, Xiaowu; Wang, Feng; Hu, Zhihong; Yang, Xinsen
2018-01-01
Steam and water pressure drop is one of the most important characteristics in the boiler performance test. As the measuring points are not in the guaranteed position and the test condition fluctuation exsits, the pressure drop test of steam and water system has the deviation of measuring point position and the deviation of test running parameter. In order to get accurate pressure drop of steam and water system, the corresponding correction should be carried out. This paper introduces the correction method of steam and water pressure drop in boiler performance test.
Canaani, Ora; Malkin, Shmuel; Mauzerall, David
1988-01-01
Photoacoustic signals from intact leaves, produced upon excitation with single-turnover flashes, were shown to be dependent on their position in the flash sequence. Compared to the signal obtained from the first flash, all the others were time-shifted and had increased amplitudes. The signal from the third flash had the largest deviation, whereas that from the second flash deviated only minimally. The amplitude difference of the signals relative to that from the first flash was measured at a convenient time point (5 ms) and showed oscillations of period 4, similar to the O2-evolution pattern from algae. These oscillations were strongly damped, tending to a steady state from about the seventh flash on. The extra photoacoustic signal (relative to the first flash) was shown to be inhibited by 3-(3,4-dichlorophenyl)-1,1-dimethylurea, heat treatment, or water infiltration. Its change with flash number, its saturation with increasing flash energy, and the above inhibition criteria indicate that it originates in pulsed O2 evolution. The sound wave produced by the first flash, however, arose by a photothermal mechanism only, as shown by its linear dependence on the flash intensity and insensitivity to the above treatments. The above flash pattern demonstrates that the photocycle of the S states (i.e., positive charge accumulation before two water molecules can be oxidized in a concerted way to produce molecular oxygen) occurs in intact leaves. It proves the applicability of the photoacoustic method for mechanistic studies of O2 evolution in leaves under physiological conditions. Water content of leaves is readily measured by this method. Images PMID:16593952
Ionospheric Anomalies on the day of the Devastating Earthquakes during 2000-2012
NASA Astrophysics Data System (ADS)
Su, Fanfan; Zhou, Yiyan; Zhu, Fuying
2013-04-01
The study of the ionospheric abnormal changes during the large earthquakes has attracted much attention for many years. Many papers have reported the deviations of Total Electron Content (TEC) around the epicenter. The statistical analysis concludes that the anomalous behavior of TEC is related with the earthquakes with high probability[1]. But the special cases have different features[2][3]. In this study, we carry out a new statistical analysis to investigate the nature of the ionospheric anomalies during the devastating earthquakes. To demonstrate the abnormal changes of the ionospheric TEC, we have examined the TEC database from the Global Ionosphere Map (GIM). The GIM ( ftp://cddisa.gsfc.nasa.gov/pub/gps/products/ionex) includes about 200 of worldwide ground-based receivers of the GPS. The TEC data with resolution of 5° longitude and 2.5° latitude are routinely published in a 2-h time interval. The information of earthquakes is obtained from the USGS ( http://earthquake.usgs.gov/earthquakes/eqarchives/epic/). To avoid the interference of the magnetic storm, the days with Dst≤-20 nT are excluded. Finally, a total of 13 M≥8.0 earthquakes in the global area during 2000-2012 are selected. The 27 days before the main shock are treated as the background days. Here, 27-day TEC median (Me) and the standard deviation (σ) are used to detect the variation of TEC. We set the upper bound BU = Me + 3*σ, and the lower bound BL = Me - 3*σ. Therefore the probability of a new TEC in the interval (BL, BU) is approximately 99.7%. If TEC varies between BU and BL, the deviation (DTEC) equals zero. Otherwise, the deviations between TEC and bounds are calculated as DTEC = BU/BL - TEC. From the deviations, the positive and negative abnormal changes of TEC can be evaluated. We investigate temporal and spatial signatures of the ionospheric anomalies on the day of the devastating earthquakes(M≥8.0). The results show that the occurrence rates of positive anomaly and negative anomaly are almost equal. The most significant anomaly on the day may occur at the time very close to the main shock, but sometimes it is not the case. The positions of the maximal deviations always deviate from the epicenter. The direction may be southeast, southwest, northeast or northwest with the almost equal probability. The anomalies may move to the epicenter, deviate to any direction, or stay at the same position and gradually fade out. There is no significant feature, such as occurrence time, position, or motion, and so on, which can indicate the source of the anomalies. References: [1].Le, H., J. Y. Liu, et al. (2011). "A statistical analysis of ionospheric anomalies before 736 M6.0+earthquakes during 2002-2010." J. Geophys. Res. 116. [2].Liu, J. Y., Y. I. Chen, et al. (2009). "Seismoionospheric GPS total electron content anomalies observed before the 12 May 2008 Mw7.9 Wenchuan earthquake." J. Geophys. Res. 114. [3].Rolland, L. M., P. Lognonne, et al. (2011). "Detection and modeling of Rayleigh wave induced patterns in the ionosphere." J. Geophys. Res. 116.
März, Karoline; Adler, Werner; Matta, Ragai-Edward; Wolf, Linda; Wichmann, Manfred; Bergauer, Bastian
2017-05-01
Orthodontists influence dental occlusion directly. To suggest any link between dental occlusion and body posture is highly contentious, as evidenced by the literature. Rasterstereography, an optical technique that enables three-dimensional (3D) body measurements to be collected, has not yet been used to impartially examine whether different occlusal positions could instantaneously alter spine and body posture. We therefore set out to use this technique to nonsubjectively evaluate this question under static conditions. Optical body scans were collected for 44 subjects, using the Diers formetric 4D system, for seven different mandible positions. In total, ten spinal and body posture parameters were assessed (trunk inclination, trunk imbalance, pelvic tilt, pelvic torsion, fleche cervicale, fleche lombaire, kyphotic angle, lordotic angle, surface rotation, and lateral deviation) for each mandible position and compared with scans performed with habitual intercuspation (HIC). Significant body posture deviations were found for the fleche cervicale (position of the mandible: right eccentrically), fleche lombaire (positions of the mandible: physiologic rest position, cotton rolls on both sides, bite elevation 1 mm), and the kyphotic angle (positions of the mandible: cotton rolls on both sides, right eccentrically). No other significant differences were detected. Data for the parameters that varied with different dental occlusions generated high standard deviations. Therefore, within the limitations of this pilot study, we could not conclusively associate dental occlusion to an instantaneous impact on the tested parameters. The posture changes that we detected could also have arisen from individual neuromuscular compensation; a possibility that must now be ruled-in, or out, by further research studies with a higher number of subjects.
Patanè, Salvatore; Marte, Filippo
2011-08-04
Changing axis deviation has been rarely reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been also rarely reported during acute myocardial infarction associated with atrial fibrillation or at the end of atrial fibrillation during acute myocardial infarction. Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. Serum troponin-I is a sensitive indicator of myocardial damage but abnormal troponin-I levels have been also reported without acute coronary syndrome and without cardiac damage. Abnormal troponin-I levels after supraventricular tachycardia have been also reported. We present a case of changing axis deviation in a 49-year-old Italian man with atrial fibrillation, exogenous subclinical hyperthyroidism and troponin-I positive without acute coronary syndrome. Also this case focuses attention on changing axis deviation, on subclinical hyperthyroidism and on the importance of a correct evaluation of abnormal troponin-I levels. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Qualitative computer aided evaluation of dental impressions in vivo.
Luthardt, Ralph G; Koch, Rainer; Rudolph, Heike; Walter, Michael H
2006-01-01
Clinical investigations dealing with the precision of different impression techniques are rare. Objective of the present study was to develop and evaluate a procedure for the qualitative analysis of the three-dimensional impression precision based on an established in-vitro procedure. The zero hypothesis to be tested was that the precision of impressions does not differ depending on the impression technique used (single-step, monophase and two-step-techniques) and on clinical variables. Digital surface data of patient's teeth prepared for crowns were gathered from standardized manufactured master casts after impressions with three different techniques were taken in a randomized order. Data-sets were analyzed for each patient in comparison with the one-step impression chosen as the reference. The qualitative analysis was limited to data-points within the 99.5%-range. Based on the color-coded representation areas with maximum deviations were determined (preparation margin and the mantle and occlusal surface). To qualitatively analyze the precision of the impression techniques, the hypothesis was tested in linear models for repeated measures factors (p < 0.05). For the positive 99.5% deviations no variables with significant influence were determined in the statistical analysis. In contrast, the impression technique and the position of the preparation margin significantly influenced the negative 99.5% deviations. The influence of clinical parameter on the deviations between impression techniques can be determined reliably using the 99.5 percentile of the deviations. An analysis regarding the areas with maximum deviations showed high clinical relevance. The preparation margin was pointed out as the weak spot of impression taking.
Kandeel, Mahmoud; Al-Taher, Abdulla; Li, Huifang; Schwingenschlogl, Udo; Al-Nazawi, Mohamed
2018-08-01
Structural studies related to Middle East Respiratory Syndrome Coronavirus (MERS CoV) infection process are so limited. In this study, molecular dynamics (MD) simulations were carried out to unravel changes in the MERS CoV heptad repeat domains (HRs) and factors affecting fusion state HR stability. Results indicated that HR trimer is more rapidly stabilized, having stable system energy and lower root mean square deviations (RMSDs). While trimers were the predominant active form of CoVs HRs, monomers were also discovered in both of viral and cellular membranes. In order to find the differences between S2 monomer and trimer molecular dynamics, S2 monomer was modelled and subjected to MD simulation. In contrast to S2 trimer, S2 monomer was unstable, having high RMSDs with major drifts above 8 Å. Fluctuation of HR residue positions revealed major changes in the C-terminal of HR2 and the linker coil between HR1 and HR2 in both monomer and trimer. Hydrophobic residues at the a and d positions of HR helices stabilize the whole system, with minimal changes in RMSD. The global distance test and contact area difference scores support instability of MERS CoV S2 monomer. Analysis of HR1-HR2 inter-residue contacts and interaction energy revealed three energy scales along HR helices. Two strong interaction energies were identified at the start of the HR2 helix and at the C-terminal of HR2. The identified critical residues by MD simulation and residues at the a and d positions of HR helix were strong stabilizers of HR recognition. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Xiaoliang; Luo, Lei; Li, Pengwei; Yu, Qingkui
2018-03-01
The image sensor in satellite optical communication system may generate noise due to space irradiation damage, leading to deviation for the determination of the light spot centroid. Based on the irradiation test data of CMOS devices, simulated defect spots in different sizes have been used for calculating the centroid deviation value by grey-level centroid algorithm. The impact on tracking & pointing accuracy of the system has been analyzed. The results show that both the amount and the position of irradiation-induced defect pixels contribute to spot centroid deviation. And the larger spot has less deviation. At last, considering the space radiation damage, suggestions are made for the constraints of spot size selection.
Trophic magnification of PCBs and its relationship to the octanol-water partition coefficient
Walters, D.M.; Mills, M.A.; Cade, B.S.; Burkard, L.P.
2011-01-01
We investigated polychlorinated biphenyl (PCB) bioaccumulation relative to octanol-water partition coefficient (KOW) and organism trophic position (TP) at the Lake Hartwell Superfund site (South Carolina). We measured PCBs (127 congeners) and stable isotopes (??15N) in sediment, organic matter, phytoplankton, zooplankton, macroinvertebrates, and fish. TP, as calculated from ??15N, was significantly, positively related to PCB concentrations, and food web trophic magnification factors (TMFs) ranged from 1.5-6.6 among congeners. TMFs of individual congeners increased strongly with log KOW, as did the predictive power (r2) of individual TP-PCB regression models used to calculate TMFs. We developed log KOW-TMF models for eight food webs with vastly different environments (freshwater, marine, arctic, temperate) and species composition (cold- vs warmblooded consumers). The effect of KOW on congener TMFs varied strongly across food webs (model slopes 0.0-15.0) because the range of TMFs among studies was also highly variable. We standardized TMFs within studies to mean = 0, standard deviation (SD) = 1 to normalize for scale differences and found a remarkably consistent KOW effect on TMFs (no difference in model slopes among food webs). Our findings underscore the importance of hydrophobicity (as characterized by KOW) in regulating bioaccumulation of recalcitrant compounds in aquatic systems, and demonstrate that relationships between chemical KOW and bioaccumulation from field studies are more generalized than previously recognized. ?? This article not subject to U.S. Copyright. Published 2011 by the American Chemical Society.
Trophic magnification of PCBs and Its relationship to the octanol-water partition coefficient.
Walters, David M; Mills, Marc A; Cade, Brian S; Burkard, Lawrence P
2011-05-01
We investigated polychlorinated biphenyl (PCB) bioaccumulation relative to octanol-water partition coefficient (K(OW)) and organism trophic position (TP) at the Lake Hartwell Superfund site (South Carolina). We measured PCBs (127 congeners) and stable isotopes (δ¹⁵N) in sediment, organic matter, phytoplankton, zooplankton, macroinvertebrates, and fish. TP, as calculated from δ¹⁵N, was significantly, positively related to PCB concentrations, and food web trophic magnification factors (TMFs) ranged from 1.5-6.6 among congeners. TMFs of individual congeners increased strongly with log K(OW), as did the predictive power (r²) of individual TP-PCB regression models used to calculate TMFs. We developed log K(OW)-TMF models for eight food webs with vastly different environments (freshwater, marine, arctic, temperate) and species composition (cold- vs warmblooded consumers). The effect of K(OW) on congener TMFs varied strongly across food webs (model slopes 0.0-15.0) because the range of TMFs among studies was also highly variable. We standardized TMFs within studies to mean = 0, standard deviation (SD) = 1 to normalize for scale differences and found a remarkably consistent K(OW) effect on TMFs (no difference in model slopes among food webs). Our findings underscore the importance of hydrophobicity (as characterized by K(OW)) in regulating bioaccumulation of recalcitrant compounds in aquatic systems, and demonstrate that relationships between chemical K(OW) and bioaccumulation from field studies are more generalized than previously recognized.
Mediastinal hemorrhage: An evaluation of radiographic manifestations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodring, J.H.; Loh, F.K.; Kryscio, R.J.
1984-04-01
Eleven common radiographic signs of mediastinal hemorrhage were evaluated by two observers for the following three patient groups: normal subjects, patients with mediastinal hemorrhage and no arterial injury, and patients with major thoracic arterial injury. Supine chest radiographs were studied in all cases. Four major conclusions can be made based upon these finding. M/C ratio (mediastinal width to chest width), tracheal deviation, left hemothorax, paraspinal line widening, and aorto-pulmonary window opacification do not reliably separate these three groups of patients. The diagnosis of mediastinal hemorrhage may be made if the aortic contour is abnormal or if one of the followingmore » signs is positive: abnormal mediastinal width, apical cap, widening of the right paratracheal stripe, or deviation of the nasogastric tube. Due to interobserver variation, there is good agreement between observers for the following four signs only: transverse mediastinal width, tracheal deviation, nasogastric tube deviation, nasogastric tube deviation, and right paratracheal stripe widening.« less
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
The contribution of timbre attributes to musical tension.
Farbood, Morwaread M; Price, Khen C
2017-01-01
Timbre is an auditory feature that has received relatively little attention in empirical work examining musical tension. In order to address this gap, an experiment was conducted to explore the contribution of several specific timbre attributes-inharmonicity, roughness, spectral centroid, spectral deviation, and spectral flatness-to the perception of tension. Listeners compared pairs of sounds representing low and high degrees of each attribute and indicated which sound was more tense. Although the response profiles showed that the high states corresponded with increased tension for all attributes, further analysis revealed that some attributes were strongly correlated with others. When qualitative factors, attribute correlations, and listener responses were all taken into account, there was fairly strong evidence that higher degrees of roughness, inharmonicity, and spectral flatness elicited higher tension. On the other hand, evidence that higher spectral centroid and spectral deviation corresponded to increases in tension was ambiguous.
Boonen, Bert; Schotanus, Martijn G M; Kerens, Bart; Hulsmans, Frans-Jan; Tuinebreijer, Wim E; Kort, Nanne P
2017-09-01
To assess whether there is a significant difference between the alignment of the individual femoral and tibial components (in the frontal, sagittal and horizontal planes) as calculated pre-operatively (digital plan) and the actually achieved alignment in vivo obtained with the use of patient-specific positioning guides (PSPGs) for TKA. It was hypothesised that there would be no difference between post-op implant position and pre-op digital plan. Twenty-six patients were included in this non-inferiority trial. Software permitted matching of the pre-operative MRI scan (and therefore calculated prosthesis position) to a pre-operative CT scan and then to a post-operative full-leg CT scan to determine deviations from pre-op planning in all three anatomical planes. For the femoral component, mean absolute deviations from planning were 1.8° (SD 1.3), 2.5° (SD 1.6) and 1.6° (SD 1.4) in the frontal, sagittal and transverse planes, respectively. For the tibial component, mean absolute deviations from planning were 1.7° (SD 1.2), 1.7° (SD 1.5) and 3.2° (SD 3.6) in the frontal, sagittal and transverse planes, respectively. Absolute mean deviation from planned mechanical axis was 1.9°. The a priori specified null hypothesis for equivalence testing: the difference from planning is >3 or <-3 was rejected for all comparisons except for the tibial transverse plane. PSPG was able to adequately reproduce the pre-op plan in all planes, except for the tibial rotation in the transverse plane. Possible explanations for outliers are discussed and highlight the importance for adequate training surgeons before they start using PSPG in their day-by-day practise. Prospective cohort study, Level II.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
... temporary deviation from the operating schedule that governs the draw of the US40-322 (Albany Avenue) Bridge... from the current operating regulations of the US40-322 (Albany Avenue) Bridge across Inside Thorofare... temporary deviation, the US40-322 (Albany Avenue) Bridge will remain in the closed position from 6 a.m...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-03
... to keep one lift span closed to facilitate scheduled bridge maintenance. DATES: This deviation is... temporary deviation the Ferry Street Bridge may keep one lift span in the closed position from 8 a.m. on... January 13, 2011. One lift span shall remain operational at all times. In accordance with 33 CFR 117.35(e...
77 FR 24147 - Drawbridge Operation Regulation; Mile 359.4, Missouri River, Kansas City, MO
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-23
... eight wire rope lifting cables that operate the lift span. This deviation allows the bridge to remain in the closed position while the lift cables are replaced. DATES: This deviation is effective from 10 p.m... cables that operate the lift span are replaced. The closure period will start at 10 p.m. on or about May...
77 FR 28488 - Drawbridge Operation Regulation; Upper Mississippi River, Hannibal, MO
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
... lifting cables that operate the lift span. This deviation allows the bridge to remain in the closed position while the lift cables are replaced. DATES: This deviation is effective from 9 a.m. to 3 p.m. on or... wire rope lifting cables that operate the lift span are replaced. The closure period will be from 9 a.m...
76 FR 76298 - Drawbridge Operation Regulation; Old Brazos River, Freeport, Brazoria County, TX
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-07
... deviation allows the bridge to remain closed to navigation for four days to replace lift cables. DATES: This... deviation will allow the lift span of the bridge to remain in the closed-to-navigation position in order for.... The project involves the replacement of the old swing span with the current vertical lift span. Vessel...
Global Reference Atmosphere Model (GRAM)
NASA Technical Reports Server (NTRS)
Johnson, D. L.; Blocker, Rhonda; Justus, C. G.
1993-01-01
4D model provides atmospheric parameter values either automatically at positions along linear path or along any set of connected positions specified by user. Based on actual data, GRAM provides thermal wind shear for monthly mean winds, percent deviation from standard atmosphere, mean vertical wind, and perturbation data for each position.
Plasma flow around and charge distribution of a dust cluster in a rf discharge
NASA Astrophysics Data System (ADS)
Schleede, J.; Lewerentz, L.; Bronold, F. X.; Schneider, R.; Fehske, H.
2018-04-01
We employ a particle-in-cell Monte Carlo collision/particle-particle particle-mesh simulation to study the plasma flow around and the charge distribution of a three-dimensional dust cluster in the sheath of a low-pressure rf argon discharge. The geometry of the cluster and its position in the sheath are fixed to the experimental values, prohibiting a mechanical response of the cluster. Electrically, however, the cluster and the plasma environment, mimicking also the experimental situation, are coupled self-consistently. We find a broad distribution of the charges collected by the grains. The ion flux shows on the scale of the Debye length strong focusing and shadowing inside and outside the cluster due to the attraction of the ions to the negatively charged grains, whereas the electron flux is characterized on this scale only by a weak spatial modulation of its magnitude depending on the rf phase. On the scale of the individual dust potentials, however, the electron flux deviates in the vicinity of the cluster strongly from the laminar flow associated with the plasma sheath. It develops convection patterns to compensate for the depletion of electrons inside the dust cluster.
A Novel Three-Dimensional Vector Analysis of Axial Globe Position in Thyroid Eye Disease
Guo, Jie; Yuan, Yifei; Zhang, Rui; Huang, Wenhu
2017-01-01
Purpose. To define a three-dimensional (3D) vector method to describe the axial globe position in thyroid eye disease (TED). Methods. CT data from 59 patients with TED were collected and 3D images were reconstructed. A reference coordinate system was established, and the coordinates of the corneal apex and the eyeball center were calculated to obtain the globe vector EC→. The measurement reliability was evaluated. The parameters of EC→ were analyzed and compared with the results of two-dimensional (2D) CT measurement, Hertel exophthalmometry, and strabismus tests. Results. The reliability of EC→ measurement was excellent. The difference between EC→ and 2D CT measurement was significant (p = 0.003), and EC→ was more consistent with Hertel exophthalmometry than with 2D CT measurement (p < 0.001). There was no significant difference between EC→ and Hirschberg test, and a strong correlation was found between EC→ and synoptophore test. When one eye had a larger deviation angle than its fellow, its corneal apex shifted in the corresponding direction, but the shift of the eyeball center was not significant. The parameters of EC→ were almost perfectly consistent with the geometrical equation. Conclusions. The establishment of a 3D globe vector is feasible and reliable, and it could provide more information in the axial globe position. PMID:28491471
Mora, Cordula V; Walker, Michael M
2009-09-22
How homing pigeons (Columba livia) return to their loft from distant, unfamiliar sites has long been a mystery. At many release sites, untreated birds consistently vanish from view in a direction different from the home direction, a phenomenon called the release-site bias. These deviations in flight direction have been implicated in the position determination (or map) step of navigation because they may reflect local distortions in information about location that the birds obtain from the geophysical environment at the release site. Here, we performed a post hoc analysis of the relationship between vanishing bearings and local variations in magnetic intensity using previously published datasets for pigeons homing to lofts in Germany. Vanishing bearings of both experienced and naïve birds were strongly associated with magnetic intensity variations at release sites, with 90 per cent of bearings lying within +/-29 degrees of the magnetic intensity slope or contour direction. Our results (i) demonstrate that pigeons respond in an orderly manner to the local structure of the magnetic field at release sites, (ii) provide a mechanism for the occurrence of release-site biases and (iii) suggest that pigeons may derive spatial information from the magnetic field at the release site that could be used to estimate their current position relative to their loft.
NASA Astrophysics Data System (ADS)
Protsyuk, Yu. I.; Kovylianska, O. E.; Protsyuk, S. V.; Yizhakevych, O. M.; Andruk, V. M.; Golovnia, V. V.; Yuldoshev, Q. K.
2017-02-01
The bulk of planet observations was obtained in RI MAO and MAO NASU from 1961 to 1994. Plates from AI UAS were also used. Each plate of NAO was scanned 6 times, in other observatories - only once. All images are processed, most of them are identified and the equatorial coordinates of all objects were obtained. Positional accuracy of the reference stars has value of 0.04"-0.30". Standard deviation of the planets' position is in the range 0.10-0.12 pixels, that corresponds, depending on the scale, from 0".08 to 0".26. The comparison of the new topocentric positions of the planets with JPL/HORIZONS ephemeris was made. Calculation of (O-C) values and their standard deviation is obtained.
Excited atoms in the free-burning Ar arc: treatment of the resonance radiation
NASA Astrophysics Data System (ADS)
Golubovskii, Yu; Kalanov, D.; Gortschakow, S.; Baeva, M.; Uhrlandt, D.
2016-11-01
The collisional-radiative model with an emphasis on the accurate treatment of the resonance radiation transport is developed and applied to the free-burning Ar arc plasma. This model allows for analysis of the influence of resonance radiation on the spatial density profiles of the atoms in different excited states. The comparison of the radial density profiles obtained using an effective transition probability approximation with the results of the accurate solution demonstrates the distinct impact of transport on the profiles and absolute densities of the excited atoms, especially in the arc fringes. The departures from the Saha-Boltzmann equilibrium distributions, caused by different radiative transitions, are analyzed. For the case of the DC arc, the local thermodynamic equilibrium (LTE) state holds close to the arc axis, while strong deviations from the equilibrium state on the periphery occur. In the intermediate radial positions the conditions of partial LTE are fulfilled.
FTIR Spectrum of the ν 4Band of DCOOD
NASA Astrophysics Data System (ADS)
Tan, T. L.; Goh, K. L.; Ong, P. P.; Teo, H. H.
1999-06-01
The FTIR spectrum of the ν4band of deuterated formic acid (DCOOD) has been measured with a resolution of 0.004 cm-1in the frequency range of 1120 to 1220 cm-1. A total of 1866 assigned transitions have been analyzed and fitted using a Watson'sA-reduced Hamiltonian in theIrrepresentation to derive rovibrational constants for the upper state (v4= 1) with a standard deviation of 0.00036 cm-1. In the course of the analysis, the constants for the ground state were improved by a simultaneous fit of microwave frequencies and combination differences from the infrared measurements. Due to the relatively unperturbed nature of the band, the constants can be used to accurately calculate the infrared line positions for the whole band. Although the band is a hybrid typeAandB, onlya-type transitions were strong enough to be observed. The band center is at 1170.79980 ± 0.00002 cm-1.
Atmospheric turbulence temperature on the laser wavefront properties
NASA Astrophysics Data System (ADS)
Contreras López, J. C.; Ballesteros Díaz, A.; Tíjaro Rojas, O. J.; Torres Moreno, Y.
2017-06-01
Temperature is a physical magnitude that if is higher, the refractive index presents more important random fluctuations, which produce a greater distortion in the wavefront and thus a displacement in its centroid. To observe the effect produced by the turbulent medium strongly influenced by temperature on propagation laser beam, we experimented with two variable and controllable temperature systems designed as optical turbulence generators (OTG): a Turbulator and a Parallelepiped glass container. The experimental setup use three CMOS cameras and four temperature sensors spatially distributed to acquire synchronously information of the laser beam wavefront and turbulence temperature, respectively. The acquired information was analyzed with MATLAB® software tool, that it allows to compute the position, in terms of the evolution time, of the laser beam center of mass and their deviations produced by different turbulent conditions generated inside the two manufactured systems. The results were reflected in the statistical analysis of the centroid shifting.
TLE uncertainty estimation using robust weighted differencing
NASA Astrophysics Data System (ADS)
Geul, Jacco; Mooij, Erwin; Noomen, Ron
2017-05-01
Accurate knowledge of satellite orbit errors is essential for many types of analyses. Unfortunately, for two-line elements (TLEs) this is not available. This paper presents a weighted differencing method using robust least-squares regression for estimating many important error characteristics. The method is applied to both classic and enhanced TLEs, compared to previous implementations, and validated using Global Positioning System (GPS) solutions for the GOCE satellite in Low-Earth Orbit (LEO), prior to its re-entry. The method is found to be more accurate than previous TLE differencing efforts in estimating initial uncertainty, as well as error growth. The method also proves more reliable and requires no data filtering (such as outlier removal). Sensitivity analysis shows a strong relationship between argument of latitude and covariance (standard deviations and correlations), which the method is able to approximate. Overall, the method proves accurate, computationally fast, and robust, and is applicable to any object in the satellite catalogue (SATCAT).
Robust tunability of magnetoresistance in half-Heusler R PtBi ( R = Gd , Dy, Tm, and Lu) compounds
Mun, Eundeok; Bud'ko, Sergey L.; Canfield, Paul C.
2016-03-15
We present the magnetic field dependencies of transport properties for RPtBi ( R = Gd, Dy, Tm, and Lu) half-Heusler compounds. Temperature- and field-dependent resistivity measurements of high-quality RPtBi single crystals reveal an unusually large, nonsaturating magnetoresistance (MR) up to 300 K under a moderate magnetic field of H = 140 kOe. At 300 K, the large MR effect decreases as the rare earth is traversed from Gd to Lu and the magnetic field dependence of MR shows a deviation from the conventional H2 behavior. The Hall coefficient ( RH) for R = Gd indicates a sign change around 120more » K, whereas RH curves for R = Dy, Tm, and Lu remain positive for all measured temperatures. At 300 K, the Hall resistivity reveals a deviation from the linear field dependence for all compounds. Thermoelectric power measurements on this family show strong temperature and magnetic field dependencies which are consistent with resistivity measurements. A highly enhanced thermoelectric power under applied magnetic field is observed as high as ~100 μV/K at 140 kOe. Furthermore, analysis of the transport data in this series reveals that the rare-earth-based half-Heusler compounds provide opportunities to tune MR effect through lanthanide contraction and to elucidate the mechanism of nontrivial MR.« less
High spatial precision nano-imaging of polarization-sensitive plasmonic particles
NASA Astrophysics Data System (ADS)
Liu, Yunbo; Wang, Yipei; Lee, Somin Eunice
2018-02-01
Precise polarimetric imaging of polarization-sensitive nanoparticles is essential for resolving their accurate spatial positions beyond the diffraction limit. However, conventional technologies currently suffer from beam deviation errors which cannot be corrected beyond the diffraction limit. To overcome this issue, we experimentally demonstrate a spatially stable nano-imaging system for polarization-sensitive nanoparticles. In this study, we show that by integrating a voltage-tunable imaging variable polarizer with optical microscopy, we are able to suppress beam deviation errors. We expect that this nano-imaging system should allow for acquisition of accurate positional and polarization information from individual nanoparticles in applications where real-time, high precision spatial information is required.
Study of Measurement Strategies of Geometric Deviation of the Position of the Threaded Holes
NASA Astrophysics Data System (ADS)
Drbul, Mário; Martikan, Pavol; Sajgalik, Michal; Czan, Andrej; Broncek, Jozef; Babik, Ondrej
2017-12-01
Verification of product and quality control is an integral part of current production process. In terms of functional requirements and product interoperability, it is necessary to analyze their dimensional and also geometric specifications. Threaded holes are verified elements too, which are a substantial part of detachable screw connections and have a broad presence in engineering products. This paper deals with on the analysing of measurement strategies of verification geometric deviation of the position of the threaded holes, which are the indirect method of measuring threaded pins when applying different measurement strategies which can affect the result of the verification of the product..
NASA Technical Reports Server (NTRS)
Knox, C. E.
1978-01-01
Navigation error data from these flights are presented in a format utilizing three independent axes - horizontal, vertical, and time. The navigation position estimate error term and the autopilot flight technical error term are combined to form the total navigation error in each axis. This method of error presentation allows comparisons to be made between other 2-, 3-, or 4-D navigation systems and allows experimental or theoretical determination of the navigation error terms. Position estimate error data are presented with the navigation system position estimate based on dual DME radio updates that are smoothed with inertial velocities, dual DME radio updates that are smoothed with true airspeed and magnetic heading, and inertial velocity updates only. The normal mode of navigation with dual DME updates that are smoothed with inertial velocities resulted in a mean error of 390 m with a standard deviation of 150 m in the horizontal axis; a mean error of 1.5 m low with a standard deviation of less than 11 m in the vertical axis; and a mean error as low as 252 m with a standard deviation of 123 m in the time axis.
76 FR 52565 - Drawbridge Operation Regulation; Illinois Waterway, Joliet, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-23
... in the closed-to- navigation position for ten hours. DATES: This deviation is effective from 8 a.m... Joliet, Illinois to remain in the closed-to-navigation position for ten hours while repair work is done...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Studenski, M; Yang, F
Purpose: MRI-guided-radiotherapy (MRIGRT) systems lack many features of traditional Linac based RT systems and specialized tests need to be developed to evaluate MLC performance. This work describes automatic tools for the analysis of positional accuracy of an MLC equipped MRIGRT system. Methods: This MLC analysis tool was developed for the MRIdian™ RT system which has three Co-60 equipped treatment heads each with a double focused MLC containing 30 leaf pairs, leaf thickness is 1.05cm defined at isocenter (SAD 105 cm). For MLC positional analysis a picket fence test was performed using a 25.4cm × 25.4cm Gafchromic™ RTQA2 film placed betweenmore » 5cm solidwater and a 30cm × 30cm × 1cm jigwire phantom with seven embedded parallel metal strips 4cm apart. A plan was generated to deliver 2Gy per field and seven 23.1cm × 2cm fields centered over each wire in the phantom. For each leaf pair the center of the radiation profile was determined by fitting the horizontal profile with a Gaussian model and determining the center of the FWHM. This was compared with the metal strip location to determine any deviation. The following metrics were used to evaluate the deviations per gantry angle including maximum, minimum, mean, Kurtosis, and skewness. Results: The identified maximum/mean leaf deviations are, 1.32/0.55 mm for gantry 0°, 1.59/0.76 mm for gantry 90°, and 1.19/0.39 mm for gantry 270°. The percentage of leaf deviation less than 1mm are 90.0% at 0°, 74.6% at 90°, and 97.0% at 270°. Kurtosis/skewness of the leaf deviation are 2.41/0.14 at 0°, 2.53/0.23 at 90°, 3.33/0.83 at 270°, respectively. Conclusion: This work presents an automatic tool for evaluation of the MLC position accuracy of the MRIdian™ radiotherapy system which can be used to benchmark the performance of the MLC system for each treatment head and track the results longitudinally.« less
Hydrogen-water vapor mixtures: Control of hydrothermal atmospheres by hydrogen osmosis
Shaw, H.R.
1963-01-01
Experiments at 700??C and 800 bars total pressure demonstrate positive deviations from ideality for mixtures of hydrogen and H2O gases. The deviations are greater than predicted with Stockmayer's method. The composition of the mixture and the fugacity of hydrogen are controlled by diffusing hydrogen through metallic membranes. The results give the fugacities of both H 2O and oxygen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santoro, J. P.; McNamara, J.; Yorke, E.
2012-10-15
Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged imagesmore » for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.« less
A computer aided treatment event recognition system in radiation therapy.
Xia, Junyi; Mart, Christopher; Bayouth, John
2014-01-01
To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012-November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors' clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when executed on either a desktop computer or a mobile device. CATERS offers an effective tool to detect and report treatment events. Automation and rapid processing enables electronic record interrogation daily, alerting the medical physicist of deviations potentially days prior to performing weekly check. The output of CATERS could also be utilized as an important input to failure mode and effects analysis.
Shieh, Yiwey; Hu, Donglei; Ma, Lin; Huntsman, Scott; Gard, Charlotte C; Leung, Jessica W T; Tice, Jeffrey A; Ziv, Elad; Kerlikowske, Karla; Cummings, Steven R
2017-11-01
Models that predict the risk of estrogen receptor (ER)-positive breast cancers may improve our ability to target chemoprevention. We investigated the contributions of sex hormones to the discrimination of the Breast Cancer Surveillance Consortium (BCSC) risk model and a polygenic risk score comprised of 83 single nucleotide polymorphisms. We conducted a nested case-control study of 110 women with ER-positive breast cancers and 214 matched controls within a mammography screening cohort. Participants were postmenopausal and not on hormonal therapy. The associations of estradiol, estrone, testosterone, and sex hormone binding globulin with ER-positive breast cancer were evaluated using conditional logistic regression. We assessed the individual and combined discrimination of estradiol, the BCSC risk score, and polygenic risk score using the area under the receiver operating characteristic curve (AUROC). Of the sex hormones assessed, estradiol (OR 3.64, 95% CI 1.64-8.06 for top vs bottom quartile), and to a lesser degree estrone, was most strongly associated with ER-positive breast cancer in unadjusted analysis. The BCSC risk score (OR 1.32, 95% CI 1.00-1.75 per 1% increase) and polygenic risk score (OR 1.58, 95% CI 1.06-2.36 per standard deviation) were also associated with ER-positive cancers. A model containing the BCSC risk score, polygenic risk score, and estradiol levels showed good discrimination for ER-positive cancers (AUROC 0.72, 95% CI 0.65-0.79), representing a significant improvement over the BCSC risk score (AUROC 0.58, 95% CI 0.50-0.65). Adding estradiol and a polygenic risk score to a clinical risk model improves discrimination for postmenopausal ER-positive breast cancers.
Defining Noble Gas Partitioning for Carbon Capture and Storage Environments
NASA Astrophysics Data System (ADS)
Warr, O.; Masters, A.; Rochelle, C.; Ballentine, C. J.
2014-12-01
For viable CCS implementation variables such as CO2 dissolution rates, reactions with the host rock and the extent of groundwater interaction must be accurately constrained. Noble gases play an important role in these systems [e.g. 1,2]. Their application, however, requires accurate Henry's constants within dense CO2-H2O systems. Current interpretations use pure noble gas-H2O partitioning data [3,4] and assume CO2-noble gas interactions are negligible, even at high (>700 kg/m3) CO2 densities [2]. To test this assumption we experimentally determined noble gas CO2-H2O partitioning for the 170-656 kg/m3 CO2 density range; representative of most CCS environments. Contrary to assumption, CO2 density significantly affected noble gas partition coefficients. For helium, increasing CO2 density resulted in a negative deviation trend from CO2-free values whilst for argon, krypton and xenon strong, positive deviations were observed. At 656 kg/m3 these deviations were -35%, 74%, 114% and 321% respectively. This is interpreted as the CO2 phase acting as a polar solvent inducing polarisation in the noble gases. Deviation trends are well defined using a 2nd order polynomial. The effect of a dense CO2 phase can now be incorporated into existing noble gas models. We also present results from a Gibbs-Ensemble Monte Carlo molecular simulation to model partitioning for this binary system. This fundamental technique makes predictions based on the pair-potentials of interaction between the molecules. Here it gives the phase compositions and Henry coefficients for noble gases. With a proven ability in accurately replicating both the CO2-H2O system and low pressure noble gas Henry constants the focus is now on fully optimising the model to match high pressure observations. [1] Gilfillan et al. (2009) Nature 458 614-618 [2] Gilfillan et al. (2008) GCA 72 1174-1198 [3] Crovetto et al. (1982) J.Chem.Phys. 76 1077-1086 [4] Ballentine et al. in Porcelli et al. (eds.) (2002) Rev.Min.Geo. 47 539-614.
Linear maps preserving maximal deviation and the Jordan structure of quantum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamhalter, Jan
2012-12-15
In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only onemore » numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnar.« less
NASA Technical Reports Server (NTRS)
Wolf, David A.; Schwarz, Ray P.
1992-01-01
Measurements were taken of the path of a simulated typical tissue segment or 'particle' within a rotating fluid as a function of gravitational strength, fluid rotation rate, particle sedimentation rate, and particle initial position. Parameters were examined within the useful range for tissue culture in the NASA rotating wall culture vessels. The particle moves along a nearly circular path through the fluid (as observed from the rotating reference frame of the fluid) at the same speed as its linear terminal sedimentation speed for the external gravitational field. This gravitationally induced motion causes an increasing deviation of the particle from its original position within the fluid for a decreased rotational rate, for a more rapidly sedimenting particle, and for an increased gravitational strength. Under low gravity conditions (less than 0.1 G), the particle's motion through the fluid and its deviation from its original position become negligible. Under unit gravity conditions, large distortions (greater than 0.25 inch) occur even for particles of slow sedimentation rate (less than 1.0 cm/sec). The particle's motion is nearly independent of the particle's initial position. Comparison with mathematically predicted particle paths show that a significant error in the mathematically predicted path occurs for large particle deviations. This results from a geometric approximation and numerically accumulating error in the mathematical technique.
Considerations on the mechanisms of alternating skew deviation in patients with cerebellar lesions.
Zee, D S
1996-01-01
Alternating skew deviation, in which the side of the higher eye changes depending upon whether gaze is directed to the left or the right, is a frequent sign in patients with posterior fossa lesions, including those restricted to the cerebellum. Here we propose a mechanism for alternating skews related to the otolith-ocular responses to fore and aft pitch of the head in lateral-eyed animals. In lateral-eyed animals the expected response to a static head pitch is cyclorotation of the eyes. But if the eyes are rotated horizontally in the orbit, away from the primary position, a compensatory skew deviation should also appear. The direction of the skew would depend upon whether the eyes were directed to the right (left eye forward, right eye backward) or to the left (left eye backward, right eye forward). In contrast, for frontal-eyed animals, skew deviations are counterproductive because they create diplopia and interfere with binocular vision. We attribute the emergence of skew deviations in frontal-eyed animals in pathological conditions to 1) an imbalance in otolithocular pathways and 2) a loss of the component of ocular motor innervation that normally corrects for the differences in pulling directions and strengths of the various ocular muscles as the eyes change position in the orbit. Such a compensatory mechanism is necessary to ensure optimal binocular visual function during and after head motion. This compensatory mechanism may depend upon the cerebellum.
Revealing modified gravity signals in matter and halo hierarchical clustering
NASA Astrophysics Data System (ADS)
Hellwing, Wojciech A.; Koyama, Kazuya; Bose, Benjamin; Zhao, Gong-Bo
2017-07-01
We use a set of N-body simulations employing a modified gravity (MG) model with Vainshtein screening to study matter and halo hierarchical clustering. As test-case scenarios we consider two normal branch Dvali-Gabadadze-Porrati (nDGP) gravity models with mild and strong growth rate enhancement. We study higher-order correlation functions ξn(R ) up to n =9 and associated reduced cumulants Sn(R )≡ξn(R )/σ (R )2n -2. We find that the matter probability distribution functions are strongly affected by the fifth force on scales up to 50 h-1 Mpc , and the deviations from general relativity (GR) are maximized at z =0 . For reduced cumulants Sn, we find that at small scales R ≤6 h-1 Mpc the MG is characterized by lower values, with the deviation growing from 7% in the reduced skewness up to even 40% in S5. To study the halo clustering we use a simple abundance matching and divide haloes into thee fixed number density samples. The halo two-point functions are weakly affected, with a relative boost of the order of a few percent appearing only at the smallest pair separations (r ≤5 h-1 Mpc ). In contrast, we find a strong MG signal in Sn(R )'s, which are enhanced compared to GR. The strong model exhibits a >3 σ level signal at various scales for all halo samples and in all cumulants. In this context, we find that the reduced kurtosis to be an especially promising cosmological probe of MG. Even the mild nDGP model leaves a 3 σ imprint at small scales R ≤3 h-1 Mpc , while the stronger model deviates from a GR signature at nearly all scales with a significance of >5 σ . Since the signal is persistent in all halo samples and over a range of scales, we advocate that the reduced kurtosis estimated from galaxy catalogs can potentially constitute a strong MG-model discriminatory as well as GR self-consistency test.
Last Millennium ENSO-Mean State Interactions in the Tropical Pacific
NASA Astrophysics Data System (ADS)
Wyman, D. A.; Conroy, J. L.; Karamperidou, C.
2017-12-01
The nature and degree of interaction between the mean state of the tropical Pacific and ENSO remains an open question. Here we use high temporal resolution, tropical Pacific sea surface temperature (SST) records from the last millennium to investigate the relationship between ENSO and the tropical Pacific zonal sea surface temperature gradient (hereafter dSST). A dSST time series was created by standardizing, interpolating, and compositing 7 SST records from the western and 3 SST records from the eastern tropical Pacific. Propagating the age uncertainty of each of these records was accomplished through a Monte Carlo Empirical Orthogonal Function analysis. We find last millennium dSST is strong from 700 to 1300 CE, begins to weaken at approximately 1300 CE, and decreases more rapidly at 1700 CE. dSST was compared to 14 different ENSO reconstructions, independent of the records used to create dSST, to assess the nature of the ENSO-mean state relationship. dSST correlations with 50-year standard deviations of ENSO reconstructions are consistently negative, suggesting that more frequent, strong El Niño events on this timescale reduces dSST. To further assess the strength and direction of the ENSO-dSST relationship, moving 100-year standard deviations of ENSO reconstructions were compared to moving 100-year averages of dSST using Cohen's Kappa statistic, which measures categorical agreement. The Li et al. (2011) and Li et al. (2013) Nino 3.4 ENSO reconstructions had the highest agreement with dSST (k=0.80 and 0.70, respectively), with greater ENSO standard deviation coincident with periods of weak dSST. Other ENSO reconstructions showed weaker agreement with dSST, which may be partly due to low sample size. The consistent directional agreement of dSST with ENSO, coupled with the inability of strong ENSO events to develop under a weak SST gradient, suggests periods of more frequent strong El Niño events reduced tropical Pacific dSST on centennial timescales over the last millennium.
Tang, Tao; Chen, Sisi; Huang, Xuanlin; Yang, Tao; Qi, Bo
2018-01-01
High-performance position control can be improved by the compensation of disturbances for a gear-driven control system. This paper presents a mode-free disturbance observer (DOB) based on sensor-fusion to reduce some errors related disturbances for a gear-driven gimbal. This DOB uses the rate deviation to detect disturbances for implementation of a high-gain compensator. In comparison with the angular position signal the rate deviation between load and motor can exhibits the disturbances exiting in the gear-driven gimbal quickly. Due to high bandwidth of the motor rate closed loop, the inverse model of the plant is not necessary to implement DOB. Besides, this DOB requires neither complex modeling of plant nor the use of additive sensors. Without rate sensors providing angular rate, the rate deviation is easily detected by encoders mounted on the side of motor and load, respectively. Extensive experiments are provided to demonstrate the benefits of the proposed algorithm. PMID:29498643
Tang, Tao; Chen, Sisi; Huang, Xuanlin; Yang, Tao; Qi, Bo
2018-03-02
High-performance position control can be improved by the compensation of disturbances for a gear-driven control system. This paper presents a mode-free disturbance observer (DOB) based on sensor-fusion to reduce some errors related disturbances for a gear-driven gimbal. This DOB uses the rate deviation to detect disturbances for implementation of a high-gain compensator. In comparison with the angular position signal the rate deviation between load and motor can exhibits the disturbances exiting in the gear-driven gimbal quickly. Due to high bandwidth of the motor rate closed loop, the inverse model of the plant is not necessary to implement DOB. Besides, this DOB requires neither complex modeling of plant nor the use of additive sensors. Without rate sensors providing angular rate, the rate deviation is easily detected by encoders mounted on the side of motor and load, respectively. Extensive experiments are provided to demonstrate the benefits of the proposed algorithm.
Maeda, Yoshikazu; Sato, Yoshitaka; Shibata, Satoshi; Bou, Sayuri; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Fuwa, Nobukazu; Takamatsu, Shigeyuki; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Minami, Hiroki; Saga, Yusuke; Saito, Makoto
2018-05-01
We quantified interfractional movements of the prostate, seminal vesicles (SVs), and rectum during computed tomography (CT) image-guided proton therapy for prostate cancer and studied the range variation in opposed lateral proton beams. We analyzed 375 sets of daily CT images acquired throughout the proton therapy treatment of ten patients. We analyzed daily movements of the prostate, SVs, and rectum by simulating three image-matching strategies: bone matching, prostate center (PC) matching, and prostate-rectum boundary (PRB) matching. In the PC matching, translational movements of the prostate center were corrected after bone matching. In the PRB matching, we performed PC matching and correction along the anterior-posterior direction to match the boundary between the prostate and the rectum's anterior region. In each strategy, we evaluated systematic errors (Σ) and random errors (σ) by measuring the daily movements of certain points on each anatomic structure. The average positional deviations in millimeter of each point were determined by the Van Herk formula of 2.5Σ + 0.7σ. Using these positional deviations, we created planning target volumes of the prostate and SVs and analyzed the daily variation in the water equivalent length (WEL) from the skin surface to the target along the lateral beam directions using the density converted from the daily CT number. Based on this analysis, we designed prostate cancer treatment planning and evaluated the dose volume histograms (DVHs) for these strategies. The SVs' daily movements showed large variations over the superior-inferior direction, as did the rectum's anterior region. The average positional deviations of the prostate in the anterior, posterior, superior, inferior, and lateral sides (mm) in bone matching, PC matching, and PRB matching were (8.9, 9.8, 7.5, 3.6, 1.6), (5.6, 6.1, 3.5, 4.5, 1.9), and (8.6, 3.2, 3.5, 4.5, 1.9) (mm), respectively. Moreover, the ones of the SV tip were similarly (22.5, 15.5, 11.0, 7.6, 6.0), (11.8, 8.4, 7.8, 5.2, 6.3), and (9.9, 7.5, 7.8, 5.2, 6.3). PRB matching showed the smallest positional deviations at all portions except for the anterior portion of the prostate and was able to markedly reduce the positional deviations at the posterior portion. The averaged WEL variations at the distal and proximal sides of planning target volumes were estimated 7-9 mm and 4-6 mm, respectively, and showed the increasing of a few millimeters in PC and PRB matching compared to bone matching. In the treatment planning simulation, the DVH values of the rectum in PRB matching were reduced compared to those obtained with other matching strategies. The positional deviations for the prostate on the posterior side and the SVs were smaller by PRB matching than the other strategies and effectively reduced the rectal dose. 3D dose calculations indicate that PRB matching with CT image guidance may do a better job relative to other positioning methods to effectively reduce the rectal complications. The WEL variation was quite large, and the appropriate margin (approx. 10 mm) must be adapted to the proton range in an initial planning to maintain the coverage of target volumes throughout entire treatment. © 2018 American Association of Physicists in Medicine.
Higher-Order Corrections to Earthʼs Ionosphere Shocks
NASA Astrophysics Data System (ADS)
Abdelwahed, H. G.; El-Shewy, E. K.
2017-01-01
Nonlinear shock wave structures in unmagnetized collisionless viscous plasmas composed fluid of positive (negative) ions and nonthermally electron distribution are examined. For ion shock formation, a reductive perturbation technique applied to derive Burgers equation for lowest-order potential. As the shock amplitude decreasing or enlarging, its steepness and velocity deviate from Burger equation. Burgers type equation with higher order dissipation must be obtained to avoid this deviation. Solution for the compined two equations has been derived using renormalization analysis. Effects of higher-order, positive- negative mass ratio Q, electron nonthermal parameter δ and kinematic viscosities coefficient of positive (negative) ions {η }1 and {η }2 on the electrostatic shocks in Earth’s ionosphere are also argued. Supported by the Deanship of Scientific Research at Prince Sattam Bin Abdulaziz University under the Research Project No. 2015/01/4787
Khalil, E; Najjar, S; Sallam, A
2000-04-01
Aqueous solubility of diclofenac diethylamine (DDEA), a nonsteroidal anti-inflammatory drug currently formulated as a topical emulgel, was studied in the presence of pharmaceutical additives and compared with diclofenac sodium (DS). Electrolytes at low concentrations exhibited a salting-in effect on DDEA with peak solubility that was attributed to the association of DDEA into micelles, followed by a salting-out effect at higher concentrations, by which structure formation by DDEA molecules increased and precipitation occurred. For DS, which is not capable of forming micelles, the salting-out effect was dominant due to the common ion effect. Cosolvents displayed significant enhancement in solubility of both salts except glycerol, which showed a slight increase in solubility of DDEA and a decrease in solubility of DS due to transformation into the less soluble hydrate form. Ethanol and polyethylene glycol (PEG) 400 cosolvent systems at all concentrations showed positive deviations from the log-linear solubility equation. In the case of propylene glycol (PG) cosolvent systems, negative deviations were observed at low volume fractions of cosolvent, while positive deviations were observed at high volume fractions of cosolvent for DS and DDEA. The parent drug, being less ionizable and highly nonpolar, showed negative deviations up to 90% PG content. Thus, the positive deviations for DS and DDEA could be attributed to the more ionizable carboxylic group and its higher ability for hydrogen bonding at higher fractions of cosolvent. Polyvinylpyrrolidone (PVP) and PEG4000 or PEG6000 enhanced the solubility of DS and DDEA, with PVP exerting higher solubilizing efficiency and DS showing better solubility than DDEA. Solubilities of DS in Tween 80 (T80) and Pluronic F-127 (PF127) aqueous solutions were almost similar, while the solubility of DDEA in the presence of T80 was higher than the solubility in the presence of PF127. DS appeared to be located more in the polyoxyethylene mantle of the micelles, while DDEA was located more in the core of the micelles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trofimov, A; Carpenter, K; Shih, HA
Purpose: To quantify daily set-up variations in fractionated proton therapy of ocular melanomas, and to assess the effect on the fidelity of delivered distribution to the plan. Methods: In a typical five-fraction course, daily set-up is achieved by matching the position of fiducial markers in orthogonal radiographs to the images generated by treatment planning program. A patient maintains the required gaze direction voluntarily, without the aid of fixation devices. Confirmation radiographs are acquired to assess intrafractional changes. For this study, daily radiographs were analyzed to determine the daily iso-center position and apparent gaze direction, which were then transferred to themore » planning system to calculate the dose delivered in individual fractions, and accumulated dose for the entire course. Dose-volume metrics were compared between the planned and accumulated distributions for the tumor and organs at risk, for representative cases that varied by location within the ocular globe. Results: The analysis of the first set of cases (3 posterior, 3 transequatorial and 4 anterior tumors) revealed varying dose deviation patterns, depending on the tumor location. For anterior and posterior tumors, the largest dose increases were observed in the lens and ciliary body, while for the equatorial tumors, macula, optic nerve and disk, were most often affected. The iso-center position error was below 1.3 mm (95%-confidence interval), and the standard deviation of daily polar and azimuthal gaze set-up were 1.5 and 3 degrees, respectively. Conclusion: We quantified interfractional and intrafractional set-up variation, and estimated their effect on the delivered dose for representative cases. Current safety margins are sufficient to maintain the target coverage, however, the dose delivered to critical structures often deviates from the plan. The ongoing analysis will further explore the patterns of dose deviation, and may help to identify particular treatment scenarios which are at a higher risk for such deviations.« less
Accuracy of a laboratory-based computer implant guiding system.
Barnea, Eitan; Alt, Ido; Kolerman, Roni; Nissan, Joseph
2010-05-01
Computer-guided implant placement is a growing treatment modality in partially and totally edentulous patients, though data about the accuracy of some systems for computer-guided surgery is limited. The purpose of this study was to evaluate the accuracy of a laboratory computer-guided system. A laboratory-based computer guiding system (M Guide; MIS technologies, Shlomi, Israel) was used to place implants in a fresh sheep mandible. A second computerized tomography (CT) scan was taken after placing the implants . The drill plan figures of the planned implants were positioned using assigned software (Med3D, Heidelberg, Germany) on the second CT scan to compare the implant position with the initial planning. Values representing the implant locations of the original drill plan were compared with that of the placed implants using SPSS software. Six measurements (3 vertical, 3 horizontal) were made on each implant to assess the deviation from the initial implant planning. A repeated-measurement analysis of variance was performed comparing the location of measurement (center, abutment, apex) and type of deviation (vertical vs. horizontal). The vertical deviation (mean -0.168) was significantly smaller than the horizontal deviation (mean 1.148). The laboratory computer-based guiding system may be a viable treatment concept for placing implants. Copyright (c) 2010 Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liou, K. N.; Gu, Y.; Leung, L. R.
2013-01-01
We investigate 3-D mountains/snow effects on solar flux distributions and their impact on surface hydrology over the western United States, specifically the Rocky Mountains and Sierra Nevada. The Weather Research and Forecasting (WRF) model, applied at a 30 km grid resolution, is used in conjunction with a 3-D radiative transfer parameterization covering a time period from 1 November 2007 to 31 May 2008, during which abundant snowfall occurred. A comparison of the 3-D WRF simulation with the observed snow water equivalent (SWE) and precipitation from Snowpack Telemetry (SNOTEL) sites shows reasonable agreement in terms of spatial patterns and daily andmore » seasonal variability, although the simulation generally has a positive precipitation bias. We show that 3-D mountain features have a profound impact on the diurnal and monthly variation of surface radiative and heat fluxes, and on the consequent elevation-dependence of snowmelt and precipitation distributions. In particular, during the winter months, large deviations (3-D-PP, in which PP denotes the plane-parallel approach) of the monthly mean surface solar flux are found in the morning and afternoon hours due to shading effects for elevations below 2.5 km. During spring, positive deviations shift to the earlier morning. Over mountaintops higher than 3 km, positive deviations are found throughout the day, with the largest values of 40–60 W m -2 occurring at noon during the snowmelt season of April to May. The monthly SWE deviations averaged over the entire domain show an increase in lower elevations due to reduced snowmelt, which leads to a reduction in cumulative runoff. Over higher elevation areas, positive SWE deviations are found because of increased solar radiation available at the surface. Overall, this study shows that deviations of SWE due to 3-D radiation effects range from an increase of 18% at the lowest elevation range (1.5–2 km) to a decrease of 8% at the highest elevation range (above 3 km). Since lower elevation areas occupy larger fractions of the land surface, the net effect of 3-D radiative transfer is to extend snowmelt and snowmelt-driven runoff into the warm season.Finally, because 60–90% of water resources originate from mountains worldwide, the aforementioned differences in simulated hydrology due solely to 3-D interactions between solar radiation and mountains/snow merit further investigation in order to understand the implications of modeling mountain water resources, and these resources' vulnerability to climate change and air pollution.« less
Paul, Sarbajit; Chang, Junghwan
2017-01-01
This paper presents a design approach for a magnetic sensor module to detect mover position using the proper orthogonal decomposition-dynamic mode decomposition (POD-DMD)-based nonlinear parametric model order reduction (PMOR). The parameterization of the sensor module is achieved by using the multipolar moment matching method. Several geometric variables of the sensor module are considered while developing the parametric study. The operation of the sensor module is based on the principle of the airgap flux density distribution detection by the Hall Effect IC. Therefore, the design objective is to achieve a peak flux density (PFD) greater than 0.1 T and total harmonic distortion (THD) less than 3%. To fulfill the constraint conditions, the specifications for the sensor module is achieved by using POD-DMD based reduced model. The POD-DMD based reduced model provides a platform to analyze the high number of design models very fast, with less computational burden. Finally, with the final specifications, the experimental prototype is designed and tested. Two different modes, 90° and 120° modes respectively are used to obtain the position information of the linear motor mover. The position information thus obtained are compared with that of the linear scale data, used as a reference signal. The position information obtained using the 120° mode has a standard deviation of 0.10 mm from the reference linear scale signal, whereas the 90° mode position signal shows a deviation of 0.23 mm from the reference. The deviation in the output arises due to the mechanical tolerances introduced into the specification during the manufacturing process. This provides a scope for coupling the reliability based design optimization in the design process as a future extension. PMID:28671580
Paul, Sarbajit; Chang, Junghwan
2017-07-01
This paper presents a design approach for a magnetic sensor module to detect mover position using the proper orthogonal decomposition-dynamic mode decomposition (POD-DMD)-based nonlinear parametric model order reduction (PMOR). The parameterization of the sensor module is achieved by using the multipolar moment matching method. Several geometric variables of the sensor module are considered while developing the parametric study. The operation of the sensor module is based on the principle of the airgap flux density distribution detection by the Hall Effect IC. Therefore, the design objective is to achieve a peak flux density (PFD) greater than 0.1 T and total harmonic distortion (THD) less than 3%. To fulfill the constraint conditions, the specifications for the sensor module is achieved by using POD-DMD based reduced model. The POD-DMD based reduced model provides a platform to analyze the high number of design models very fast, with less computational burden. Finally, with the final specifications, the experimental prototype is designed and tested. Two different modes, 90° and 120° modes respectively are used to obtain the position information of the linear motor mover. The position information thus obtained are compared with that of the linear scale data, used as a reference signal. The position information obtained using the 120° mode has a standard deviation of 0.10 mm from the reference linear scale signal, whereas the 90° mode position signal shows a deviation of 0.23 mm from the reference. The deviation in the output arises due to the mechanical tolerances introduced into the specification during the manufacturing process. This provides a scope for coupling the reliability based design optimization in the design process as a future extension.
Morphology dependent near-field response in atomistic plasmonic nanocavities.
Chen, Xing; Jensen, Lasse
2018-06-21
In this work we examine how the atomistic morphologies of plasmonic dimers control the near-field response by using an atomistic electrodynamics model. At large separations, the field enhancement in the junction follows a simple inverse power law as a function of the gap separation, which agrees with classical antenna theory. However, when the separations are smaller than 0.8 nm, the so-called quantum size regime, the field enhancement is screened and thus deviates from the simple power law. Our results show that the threshold distance for the deviation depends on the specific morphology of the junction. The near field in the junction can be localized to an area of less than 1 nm2 in the presence of an atomically sharp tip, but the separation distances leading to a large confinement of near field depend strongly on the specific atomistic configuration. More importantly, the highly confined fields lead to large field gradients particularly in a tip-to-surface junction, which indicates that such a plasmonic structure favors observing strong field gradient effects in near-field spectroscopy. We find that for atomically sharp tips the field gradient becomes significant and depends strongly on the local morphology of a tip. We expect our findings to be crucial for understanding the origin of high-resolution near-field spectroscopy and for manipulating optical cavities through atomic structures in the strongly coupled plasmonic systems.
Waks, Zeev; Goldbraich, Esther; Farkash, Ariel; Torresani, Michele; Bertulli, Rossella; Restifo, Nicola; Locatelli, Paolo; Casali, Paolo; Carmeli, Boaz
2013-01-01
Clinical decision support systems (CDSSs) are gaining popularity as tools that assist physicians in optimizing medical care. These systems typically comply with evidence-based medicine and are designed with input from domain experts. Nonetheless, deviations from CDSS recommendations are abundant across a broad spectrum of disorders, raising the question as to why this phenomenon exists. Here, we analyze this gap in adherence to a clinical guidelines-based CDSS by examining the physician treatment decisions for 1329 adult soft tissue sarcoma patients in northern Italy using patient-specific parameters. Dubbing this analysis "CareGap", we find that deviations correlate strongly with certain disease features such as local versus metastatic clinical presentation. We also notice that deviations from the guideline-based CDSS suggestions occur more frequently for patients with shorter survival time. Such observations can direct physicians' attention to distinct patient cohorts that are prone to higher deviation levels from clinical practice guidelines. This illustrates the value of CareGap analysis in assessing quality of care for subsets of patients within a larger pathology.
Ionospheric disturbances under low solar activity conditions
NASA Astrophysics Data System (ADS)
Buresova, D.; Lastovicka, J.; Hejda, P.; Bochnicek, J.
2014-07-01
The paper is focused on ionospheric response to occasional magnetic disturbances above selected ionospheric stations located at middle latitudes of the Northern and Southern Hemisphere under extremely low solar activity conditions of 2007-2009. We analyzed changes in the F2 layer critical frequency foF2 and the F2 layer peak height hmF2 against 27-days running mean obtained for different longitudinal sectors of both hemispheres for the initial, main and recovery phases of selected magnetic disturbances. Our analysis showed that the effects on the middle latitude ionosphere of weak-to-moderate CIR-related magnetic storms, which mostly occur around solar minimum period, could be comparable with the effects of strong magnetic storms. In general, both positive and negative deviations of foF2 and hmF2 have been observed independent on season and location. However positive effects on foF2 prevailed and were more significant. Observations of stormy ionosphere also showed large departures from the climatology within storm recovery phase, which are comparable with those usually observed during the storm main phase. The IRI STORM model gave no reliable corrections of foF2 for analyzed events.
The Angular Power Spectrum of BATSE 3B Gamma-Ray Bursts
NASA Technical Reports Server (NTRS)
Tegmark, Max; Hartmann, Dieter H.; Briggs, Michael S.; Meegan, Charles A.
1996-01-01
We compute the angular power spectrum C(sub l) from the BATSE 3B catalog of 1122 gamma-ray bursts and find no evidence for clustering on any scale. These constraints bridge the entire range from small scales (which probe source clustering and burst repetition) to the largest scales (which constrain possible anisotropics from the Galactic halo or from nearby cosmological large-scale structures). We develop an analysis technique that takes the angular position errors into account. For specific clustering or repetition models, strong upper limits can be obtained down to scales l approx. equal to 30, corresponding to a couple of degrees on the sky. The minimum-variance burst weighting that we employ is visualized graphically as an all-sky map in which each burst is smeared out by an amount corresponding to its position uncertainty. We also present separate bandpass-filtered sky maps for the quadrupole term and for the multipole ranges l = 3-10 and l = 11-30, so that the fluctuations on different angular scales can be inspected separately for visual features such as localized 'hot spots' or structures aligned with the Galactic plane. These filtered maps reveal no apparent deviations from isotropy.
Neoclassical canons of facial beauty: Do we see the deviations?
Pavlic, Andrej; Trinajstic Zrinski, Magda; Katic, Visnja; Spalj, Stjepan
2017-05-01
To explore the presence of neoclassical canons of facial beauty among young people in Croatia and to question possible psychosocial repercussions occurring in those who demonstrate deviations in relation to canons. The study was cross-sectional and the sample included 249 subjects (60% female) aged 12-39 (median 20). Their en face and profile photographs were taken in Natural Head Position. Photogrammetry included analysis of nine neoclassical canons of facial beauty originating from the Renaissance. Psychosocial issues were assessed using the Self-Esteem Scale, Big Five Inventory and three domains of Orthognathic Quality of Life Questionnaire. Significant deviations from neoclassical facial beauty canons were observed in 55-65% of adolescents and young adults. Gender and age showed no relation to deviations. The deviations from canons that influenced the quality of life were mainly those related to vertical facial proportions and demonstrated increased facial aesthetics concern and social impact, and higher self-reported treatment need (p < 0.05). Deviations from canons were not related to self-esteem but a decrease in openness, agreeableness and neuroticism was observed. Neoclassical canons were not valid for the majority of adolescents and young adults in Croatia. Only deviations from some canons appear to provoke mild psychosocial repercussions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
The phonatory deviation diagram: a novel objective measurement of vocal function.
Madazio, Glaucya; Leão, Sylvia; Behlau, Mara
2011-01-01
To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.
Endometrioid adenocarcinoma of the uterus with a minimal deviation invasive pattern.
Landry, D; Mai, K T; Senterman, M K; Perkins, D G; Yazdi, H M; Veinot, J P; Thomas, J
2003-01-01
Minimal deviation adenocarcinoma of endometrioid type is a rare pathological entity. We describe a variant of typical endometrioid adenocarcinoma associated with minimal deviation adenocarcinoma of endometrioid type. One 'pilot' case of minimal deviation adenocarcinoma of endometrioid type associated with typical endometrioid adenocarcinoma was encountered at our institution in 2001. A second case of same type was received in consultation. We reviewed 168 consecutive hysterectomy specimens diagnosed with 'endometrioid adenocarcinoma' specifically to identify areas of minimal deviation adenocarcinoma of endometrioid type. Immunohistochemistry was done with the following antibodies: MIB1, p53, oestrogen receptor (ER), progesterone receptor (PR), cytokeratin 7 (CK7), cytokeratin 20 (CK20), carcinoembryonic antigen (CEA), and vimentin (VIM). Four additional cases of minimal deviation adenocarcinoma of endometrioid type were identified. All six cases of minimal deviation adenocarcinoma of endometrioid type were associated with superficial endometrioid adenocarcinoma. In two cases with a large amount of minimal deviation adenocarcinoma of endometrioid type, the cervix was involved. The immunoprofile of two representative cases was ER+, PR+, CK7+, CK20-, CEA-, VIM+. MIB1 immunostaining of four cases revealed little proliferative activity of the minimal deviation adenocarcinoma of endometrioid type glandular cells (0-1%) compared with the associated 'typical' endometrioid adenocarcinoma (20-30%). The same four cases showed no p53 immunostaining in minimal deviation adenocarcinoma of endometrioid type compared with a range of positive staining in the associated endometrioid adenocarcinoma. Minimal deviation adenocarcinoma of endometrioid type more often develops as a result of differentiation from typical endometrioid adenocarcinoma than de novo. Due to its deceptively benign microscopic appearance, minimal deviation adenocarcinoma of endometrioid type may be overlooked and may lead to incorrect assessment of tumour depth and pathological stage. There was a tendency for tumour with a large amount of minimal deviation adenocarcinoma of endometrioid type to invade the cervix.
Verster, Joris C; Roth, Thomas
2014-01-01
The on-the-road driving test in normal traffic is used to examine the impact of drugs on driving performance. This paper compares the sensitivity of standard deviation of lateral position (SDLP) and SD speed in detecting driving impairment. A literature search was conducted to identify studies applying the on-the-road driving test, examining the effects of anxiolytics, antidepressants, antihistamines, and hypnotics. The proportion of comparisons (treatment versus placebo) where a significant impairment was detected with SDLP and SD speed was compared. About 40% of 53 relevant papers did not report data on SD speed and/or SDLP. After placebo administration, the correlation between SDLP and SD speed was significant but did not explain much variance (r = 0.253, p = 0.0001). A significant correlation was found between ΔSDLP and ΔSD speed (treatment-placebo), explaining 48% of variance. When using SDLP as outcome measure, 67 significant treatment-placebo comparisons were found. Only 17 (25.4%) were significant when SD speed was used as outcome measure. Alternatively, for five treatment-placebo comparisons, a significant difference was found for SD speed but not for SDLP. Standard deviation of lateral position is a more sensitive outcome measure to detect driving impairment than speed variability.
An Integrated Model of Application, Admission, Enrollment, and Financial Aid
ERIC Educational Resources Information Center
DesJardins, Stephen L.; Ahlburg, Dennis A.; McCall, Brian Patrick
2006-01-01
We jointly model the application, admission, financial aid determination, and enrollment decision process. We find that expectations of admission affect application probabilities, financial aid expectations affect enrollment and application behavior, and deviations from aid expectations are strongly related to enrollment. We also conduct…
Large Deviations and Transitions Between Equilibria for Stochastic Landau-Lifshitz-Gilbert Equation
NASA Astrophysics Data System (ADS)
Brzeźniak, Zdzisław; Goldys, Ben; Jegaraj, Terence
2017-11-01
We study a stochastic Landau-Lifshitz equation on a bounded interval and with finite dimensional noise. We first show that there exists a pathwise unique solution to this equation and that this solution enjoys the maximal regularity property. Next, we prove the large deviations principle for the small noise asymptotic of solutions using the weak convergence method. An essential ingredient of the proof is the compactness, or weak to strong continuity, of the solution map for a deterministic Landau-Lifschitz equation when considered as a transformation of external fields. We then apply this large deviations principle to show that small noise can cause magnetisation reversal. We also show the importance of the shape anisotropy parameter for reducing the disturbance of the solution caused by small noise. The problem is motivated by applications from ferromagnetic nanowires to the fabrication of magnetic memories.
Heterogeneous shear elasticity of glasses: the origin of the boson peak.
Marruzzo, Alessia; Schirmacher, Walter; Fratalocchi, Andrea; Ruocco, Giancarlo
2013-01-01
The local elasticity of glasses is known to be inhomogeneous on a microscopic scale compared to that of crystalline materials. Their vibrational spectrum strongly deviates from that expected from Debye's elasticity theory: The density of states deviates from Debye's law, the sound velocity shows a negative dispersion in the boson-peak frequency regime and there is a strong increase of the sound attenuation near the boson-peak frequency. By comparing a mean-field theory of shear-elastic heterogeneity with a large-scale simulation of a soft-sphere glass we demonstrate that the observed anomalies in glasses are caused by elastic heterogeneity. By observing that the macroscopic bulk modulus is frequency independent we show that the boson-peak-related vibrational anomalies are predominantly due to the spatially fluctuating microscopic shear stresses. It is demonstrated that the boson-peak arises from the steep increase of the sound attenuation at a frequency which marks the transition from wave-like excitations to disorder-dominated ones.
NASA Astrophysics Data System (ADS)
Wang, Wenwu; Akiyama, Koji; Mizubayashi, Wataru; Nabatame, Toshihide; Ota, Hiroyuki; Toriumi, Akira
2009-03-01
We systematically studied what effect Al diffusion from high-k dielectrics had on the flatband voltage (Vfb) of Al-incorporated high-k gate stacks. An anomalous positive shift fin Vfb with the decreasing equivalent oxide thickness (EOT) of high-k gate stacks is reported. As the SiO2 interfacial layer is aggressively thinned in Al-incorporated HfxAl1-xOy gate stacks with a metal-gate electrode, the Vfb first lies on the well known linear Vfb-EOT plot and deviates toward the positive-voltage direction (Vfb roll-up), followed by shifting toward negative voltage (Vfb roll-off). We demonstrated that the Vfb roll-up behavior remarkably decreases the threshold voltage (Vth) of p-type metal-oxide-semiconductor field-effect transistors (p-MOSFETs), and does not cause severe degradation in the characteristics of hole mobility. The Vfb roll-up behavior, which is independent of gate materials but strongly dependent on high-k dielectrics, was ascribed to variations in fixed charges near the SiO2/Si interface, which are caused by Al diffusion from HfxAl1-xOy through SiO2 to the SiO2/Si interface. These results indicate that anomalous positive shift in Vfb, i.e., Vfb roll-up, should be taken into consideration in quantitatively adjusting Vfb in thin EOT regions and that it could be used to further tune Vth in p-MOSFETs.
Diffractive-refractive optics: (+,-,-,+) X-ray crystal monochromator with harmonics separation.
Hrdý, Jaromír; Mikulík, Petr; Oberta, Peter
2011-03-01
A new kind of two channel-cut crystals X-ray monochromator in dispersive (+,-,-,+) position which spatially separates harmonics is proposed. The diffracting surfaces are oriented so that the diffraction is inclined. Owing to refraction the diffracted beam is sagittally deviated. The deviation depends on wavelength and is much higher for the first harmonics than for higher harmonics. This leads to spatial harmonics separation. The idea is supported by ray-tracing simulation.
Cosmological gravitational waves
NASA Technical Reports Server (NTRS)
Linder, Eric V.
1988-01-01
A cosmological background of gravitational waves would alter the propagation of radiation, inducing redshift fluctuations, apparent source position deflections, and luminosity variations. By comparing these astrophysical effects with observations, it is possible to deduce upper limits on the energy density present in gravitational waves. Emphasis is placed on microwave background anisotropy from the redshift deviations and galaxy clustering correlation functions from the angular deviations. Many of the gravitational wave effects are shown to be generalizations of the gravitational lensing formalism.
Alcohol consumption for simulated driving performance: A systematic review.
Rezaee-Zavareh, Mohammad Saeid; Salamati, Payman; Ramezani-Binabaj, Mahdi; Saeidnejad, Mina; Rousta, Mansoureh; Shokraneh, Farhad; Rahimi-Movaghar, Vafa
2017-06-01
Alcohol consumption can lead to risky driving and increase the frequency of traffic accidents, injuries and mortalities. The main purpose of our study was to compare simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, using a systematic review. In this systematic review, electronic resources and databases including Medline via Ovid SP, EMBASE via Ovid SP, PsycINFO via Ovid SP, PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINHAL) via EBSCOhost were comprehensively and systematically searched. The randomized controlled clinical trials that compared simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, were included. Lane position standard deviation (LPSD), mean of lane position deviation (MLPD), speed, mean of speed deviation (MSD), standard deviation of speed deviation (SDSD), number of accidents (NA) and line crossing (LC) were considered as the main parameters evaluating outcomes. After title and abstract screening, the articles were enrolled for data extraction and they were evaluated for risk of biases. Thirteen papers were included in our qualitative synthesis. All included papers were classified as high risk of biases. Alcohol consumption mostly deteriorated the following performance outcomes in descending order: SDSD, LPSD, speed, MLPD, LC and NA. Our systematic review had troublesome heterogeneity. Alcohol consumption may decrease simulated driving performance in alcohol consumed people compared with non-alcohol consumed people via changes in SDSD, LPSD, speed, MLPD, LC and NA. More well-designed randomized controlled clinical trials are recommended. Copyright © 2017. Production and hosting by Elsevier B.V.
f(R) gravity and chameleon theories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brax, Philippe; Bruck, Carsten van de; Davis, Anne-Christine
2008-11-15
We analyze f(R) modifications of Einstein's gravity as dark energy models in the light of their connection with chameleon theories. Formulated as scalar-tensor theories, the f(R) theories imply the existence of a strong coupling of the scalar field to matter. This would violate all experimental gravitational tests on deviations from Newton's law. Fortunately, the existence of a matter dependent mass and a thin-shell effect allows one to alleviate these constraints. The thin-shell condition also implies strong restrictions on the cosmological dynamics of the f(R) theories. As a consequence, we find that the equation of state of dark energy is constrainedmore » to be extremely close to -1 in the recent past. We also examine the potential effects of f(R) theories in the context of the Eoet-wash experiments. We show that the requirement of a thin shell for the test bodies is not enough to guarantee a null result on deviations from Newton's law. As long as dark energy accounts for a sizeable fraction of the total energy density of the Universe, the constraints that we deduce also forbid any measurable deviation of the dark energy equation of state from -1. All in all, we find that both cosmological and laboratory tests imply that f(R) models are almost coincident with a {lambda}CDM model at the background level.« less
An approximate fluvial equilibrium topography for the Alps
NASA Astrophysics Data System (ADS)
Stüwe, K.; Hergarten, S.
2012-04-01
This contribution addresses the question whether the present topography of the Alps can be approximated by a fluvial equilibrium topography and whether this can be used to determine uplift rates. Based on a statistical analysis of the present topography we use a stream-power approach for erosion where the erosion rate is proportional to the square root of the catchment size for catchment sizes larger than 12 square kilometers and a logarithmic dependence to mimic slope processes at smaller catchment sizes. If we assume a homogeneous uplift rate over the entire region (block uplift), the best-fit fluvial equilibrium topography differs from the real topography by about 500 m RMS (root mean square) with a strong systematic deviation. Regions of low elevation are too high in the equilibrium topography, while high-mountain regions are too low. The RMS difference significantly decreases if a spatially variable uplift function is allowed. If a strong variation of the uplift rate on a scale of 5 km is allowed, the systematic deviation becomes rather small, and the RMS difference decreases to about 150 m. A significant part of the remaining deviation apparently arises from glacially-shaped valleys, while another part may result from prematurity of the relief (Hergarten, Wagner & Stüwe, EPSL 297:453, 2010). The best-fit uplift function can probably be used for forward or backward simulation of the landform evolution.
Influence of Convective Effect of Solar Winds on the CME Transit Time
NASA Astrophysics Data System (ADS)
Sun, Lu-yuan
2017-10-01
Based on an empirical model for predicting the transit time of coronal mass ejections (CMEs) proposed by Gopalswamy, 52 CME events which are related to the geomagnetic storms of Dst < -50 nT, and 10 CME events which caused extremely strong geomagnetic storms (Dst < -200 nT) in 1996- 2007 are selected, and combined with the observational data of the interplanetary solar winds that collected by the ACE satellite at 1AU, to analyze the influence of convective effect of ambient solar winds on the prediction of the CME transit time when it arrives at a place of 1 AU. After taking the convective effect of ambient solar winds into account, the standard deviation of predictions is reduced from 16.5 to 11.4 hours for the 52 CME events, and the prediction error is less than 15 hours for 68% of these events; while the standard deviation of predictions is reduced from 10.6 to 6.5 hours for the 10 CME events that caused extremely strong geomagnetic storms, and the prediction error is less than 5 hours for 6 of the 10 events. These results show that taking the convective effect of ambient solar winds into account can reduce the standard deviation of the predicted CME transit time, hence the convective effect of solar winds plays an important role for predicting the transit times of CME events.
Hassan, Elham A; Hassan, Marwa H; Torad, Faisal A
2018-05-18
The aim of the study was to correlate the clinical severity of pectus excavatum with its type and degree based on objective radiographic evaluation. Twelve brachycephalic dogs were included. Grading of the clinical severity was done based on a 6-point grading score. Thoracic radiographs were used to calculate the frontosagittal and vertebral indices at the tenth thoracic vertebra and the vertebra overlying the excavatum. Correlation between the clinical severity score and frontosagittal and vertebral indices was evaluated using Pearson's correlation coefficient. Typical pectus excavatum was recorded in the caudal sternum in seven dogs, with a mean clinical severity score of 1.7 ± 1.4, whereas in five dogs, atypical mid-sternal deviation was recorded with a mean clinical severity score of 3.8 ± 0.7. A strong correlation (r=0.7) was recorded between the clinical severity score and vertebral index in the atypical form, whereas a weak correlation (r=0.02) was recorded in the typical form (P<0.05). The clinical severity and degree of pectus excavatum was poorly correlated (r=0.3) in the typical form of pectus excavatum, whereas it was strongly correlated (r=0.9) in the atypical form. Pectus excavatum in dogs is associated with compressive cardiopulmonary dysfunction, which depends mainly on the site/type of deviation rather than the degree of deviation.
Physically Challenging Song Traits, Male Quality, and Reproductive Success in House Wrens
Cramer, Emily R. A.
2013-01-01
Physically challenging signals are likely to honestly indicate signaler quality. In trilled bird song two physically challenging parameters are vocal deviation (the speed of sound frequency modulation) and trill consistency (how precisely syllables are repeated). As predicted, in several species, they correlate with male quality, are preferred by females, and/or function in male-male signaling. Species may experience different selective pressures on their songs, however; for instance, there may be opposing selection between song complexity and song performance difficulty, such that in species where song complexity is strongly selected, there may not be strong selection on performance-based traits. I tested whether vocal deviation and trill consistency are signals of male quality in house wrens (Troglodytes aedon), a species with complex song structure. Males’ singing ability did not correlate with male quality, except that older males sang with higher trill consistency, and males with more consistent trills responded more aggressively to playback (although a previous study found no effect of stimulus trill consistency on males’ responses to playback). Males singing more challenging songs did not gain in polygyny, extra-pair paternity, or annual reproductive success. Moreover, none of the standard male quality measures I investigated correlated with mating or reproductive success. I conclude that vocal deviation and trill consistency do not signal male quality in this species. PMID:23527137
2012-01-01
Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. PMID:22686355
Vertical force and wrist deviation angle when using a walker to stand up and sit down.
Leung, Cherng-Yee; Yeh, Po-Chan
2011-08-01
Research investigating walkers suggests that safety and assistance for the elderly with weak lower limbs were important. However, the relationship between the use of a walker and the upper limbs has received little investigation. Standing up and sitting down are important daily activities. Therefore, the aim of this study was to explore wrist deviation and vertical force among elderly individuals using a walker for assistance to stand up and sit down. In total, 64 elderly volunteers (M age = 80.22, SD = 9.36) were enrolled. Data were obtained from four load cells and a twin-axis wrist goniometer. Wrist deviation and vertical force were examined when participants used a walker with horizontal handles to assist in standing up and sitting down. Significant wrist angle deviation occurred with the use of a walker, with dorsiflexion of the right hand greater than that of the left. Males exerted significantly greater vertical force. In the sitting position, greater ulnar deviation was seen among experienced walker users, whereas during standing, experienced users exhibited greater dorsiflexion. The horizontal handles of most marketed walkers may cause user wrist deviations, suggesting researchers should pursue improvements in walker design.
Verster, Joris C; Roth, Thomas
2014-07-01
The traditional outcome measure of the Dutch on-the-road driving test is the standard deviation of lateral position (SDLP), the weaving of the car. This paper explores whether excursions out-of-lane are a suitable additional outcome measure to index driving impairment. A literature search was conducted to search for driving tests that used both SDLP and excursions out-of-lane as outcome measures. The analyses were limited to studies examining hypnotic drugs because several of these drugs have been shown to produce next-morning sedation. Standard deviation of lateral position was more sensitive in demonstrating driving impairment. In fact, solely relying on excursions out-of-lane as outcome measure incorrectly classifies approximately half of impaired drives as unimpaired. The frequency of excursions out-of-lane is determined by the mean lateral position within the right traffic lane. Defining driving impairment as having a ΔSDLP > 2.4 cm, half of the impaired driving tests (51.2%, 43/84) failed to produce excursions out-of-lane. Alternatively, 20.9% of driving tests with ΔSDLP < 2.4 cm (27/129) had at least one excursion out-of-lane. Excursions out-of-lane are neither a suitable measure to demonstrate driving impairment nor is this measure sufficiently sensitive to differentiate adequately between differences in magnitude of driving impairment. Copyright © 2014 John Wiley & Sons, Ltd.
Lee, Ju-Yeun; Bae, Kunho; Park, Kyung-Ah; Lyu, In Jeong; Oh, Sei Yeul
2016-01-01
The aim of this study was to investigate extraocular muscle (EOM) volume and cross-sectional area using computed tomography (CT), and to determine the relationship between EOM size and the vertical angle of deviation in thyroid eye disease (TED). Twenty-nine TED patients (58 orbits) with vertical strabismus were enrolled in the study. All patients underwent complete ophthalmic examination including prism, alternate cover, and Krimsky tests. Orbital CT scans were also performed on each patient. Digital image analysis was used to quantify superior rectus (SR) and inferior rectus (IR) muscle cross-sectional areas and volumes. Measurements were compared with those of controls. The correlation between muscle size and degree of vertical angle deviation was evaluated. The mean vertical angle of deviation was 26.2 ± 4.1 prism diopters. The TED group had a greater maximum cross-sectional area and EOM volume in the SR and IR than the control group (all p<0.001). Area and volume of the IR were correlated with the angle of deviation, but the SR alone did not show a significant correlation. The maximum cross-sectional area and volume of [Right IR + Left SR − Right SR − Left IR] was strongly correlated with the vertical angle of deviation (P<0.001). Quantitative CT of the orbit with evaluation of the area and volume of EOMs may be helpful in anticipating and monitoring vertical strabismus in TED patients. PMID:26820406
Lee, Ju-Yeun; Bae, Kunho; Park, Kyung-Ah; Lyu, In Jeong; Oh, Sei Yeul
2016-01-01
The aim of this study was to investigate extraocular muscle (EOM) volume and cross-sectional area using computed tomography (CT), and to determine the relationship between EOM size and the vertical angle of deviation in thyroid eye disease (TED). Twenty-nine TED patients (58 orbits) with vertical strabismus were enrolled in the study. All patients underwent complete ophthalmic examination including prism, alternate cover, and Krimsky tests. Orbital CT scans were also performed on each patient. Digital image analysis was used to quantify superior rectus (SR) and inferior rectus (IR) muscle cross-sectional areas and volumes. Measurements were compared with those of controls. The correlation between muscle size and degree of vertical angle deviation was evaluated. The mean vertical angle of deviation was 26.2 ± 4.1 prism diopters. The TED group had a greater maximum cross-sectional area and EOM volume in the SR and IR than the control group (all p<0.001). Area and volume of the IR were correlated with the angle of deviation, but the SR alone did not show a significant correlation. The maximum cross-sectional area and volume of [Right IR + Left SR - Right SR - Left IR] was strongly correlated with the vertical angle of deviation (P<0.001). Quantitative CT of the orbit with evaluation of the area and volume of EOMs may be helpful in anticipating and monitoring vertical strabismus in TED patients.
COMPLEMENT DEVIATION IN SCARLET FEVER WITH COMPARATIVE STUDIES OF THE WASSERMANN AND NOGUCHI SYSTEMS
Kolmer, John A.
1911-01-01
The Wassermann reaction in scarlet fever per se is uniformly negative. The antigen of scarlet fever liver yields practically the same results as that of luetic liver, and both fail to deviate complement with scarlet fever antibodies. The Noguchi reaction in scarlet fever is practically negative. Sixteen cases, or 6.4 per cent. of 250 cases, were positive when active serum was used; with inactivated serum, but eleven, or 4.4 per cent., remained positive. Five of these eleven cases were also positive with the Wassermann system. In other words, sixteen cases, or 6.4 per cent., were positive according to the Noguchi system with active or inactivated serum or both, whereas with the Wassermann system only 2 per cent. were positive. The presence of anti-sheep hemolysin normally in human serum is one of the main disturbing factors in the Wassermann system; for this reason, complement and hemolysin (made by immunization of rabbits) require careful titration. A positive Wassermann reaction usually indicates the presence of syphilitic antibodies, and a negative Noguchi reaction, their absence, and both systems should be used in the examination of all cases. PMID:19867467
Quantitative assessment of joint position sense recovery in subacute stroke patients: a pilot study.
Kattenstroth, Jan-Christoph; Kalisch, Tobias; Kowalewski, Rebecca; Tegenthoff, Martin; Dinse, Hubert R
2013-11-01
To assess joint position sense performance in subacute stroke patients using a novel quantitative assessment. Proof-of-principle pilot study with a group of subacute stroke patients. Assessment at baseline and after 2 weeks of intervention. Additional data for a healthy age-matched control group. Ten subacute stroke patients (aged 65.41 years (standard deviation 2.5), 4 females, 2.3 weeks (standard deviation 0.2)) post-stroke receiving in-patient standard rehabilitation and repetitive electrical stimulation of the affected hand. Joint position sense was assessed based on the ability of correctly perceiving the opening angles of the finger joints. Patients had to report size differences of polystyrene balls of various sizes, whilst the balls were enclosed simultaneously by the affected and the non-affected hands. A total of 21 pairwise size comparisons was used to quantify joint position performance. After 2 weeks of therapeutic intervention a significant improvement in joint position sense performance was observed; however, the performance level was still below that of a healthy control group. The results indicate high feasibility and sensitivity of the joint position test in subacute stroke patients. Testing allowed quantification of both the deficit and the rehabilitation outcome.
``The errors were the results of errors'': Promoting Good Writing by Bad Example
NASA Astrophysics Data System (ADS)
Korsunsky, Boris
2010-01-01
We learn best by example—this adage is probably as old as teaching itself. In my own classroom, I have found that very often the students learn best from the "negative" examples. Perhaps, this shouldn't come as a surprise at all. After all, we don't react strongly to the norm—but an obvious deviation from the norm may attract our attention and make for a great teachable moment. And, if the deviation happens to be either scary or funny, the added emotional impact can create a truly powerful and lasting memory in the minds of the students.
NASA Astrophysics Data System (ADS)
Cao, Zhe; Liu, Guangdi; Zhan, Hongbin; Li, Chaozheng; You, Yuan; Yang, Chengyu; Jiang, Hang
2016-11-01
Understanding the pore networks of unconventional tight reservoirs such as tight sandstones and shales is crucial for extracting oil/gas from such reservoirs. Mercury injection capillary pressure (MICP) and N2 gas adsorption (N2GA) are performed to evaluate pore structure of Chang-7 tight sandstone. Thin section observation, scanning electron microscope, grain size analysis, mineral composition analysis, and porosity measurement are applied to investigate geological control factors of pore structure. Grain size is positively correlated with detrital mineral content and grain size standard deviation while negatively related to clay content. Detrital mineral content and grain size are positively correlated with porosity, pore throat radius and withdrawal efficiency and negatively related to capillary pressure and pore-to-throat size ratio; while interstitial material is negatively correlated with above mentioned factors. Well sorted sediments with high debris usually possess strong compaction resistance to preserve original pores. Although many inter-crystalline pores are produced in clay minerals, this type of pores is not the most important contributor to porosity. Besides this, pore shape determined by N2GA hysteresis loop is consistent with SEM observation on clay inter-crystalline pores while BJH pore volume is positively related with clay content, suggesting N2GA is suitable for describing clay inter-crystalline pores in tight sandstones.
Cao, Zhe; Liu, Guangdi; Zhan, Hongbin; Li, Chaozheng; You, Yuan; Yang, Chengyu; Jiang, Hang
2016-01-01
Understanding the pore networks of unconventional tight reservoirs such as tight sandstones and shales is crucial for extracting oil/gas from such reservoirs. Mercury injection capillary pressure (MICP) and N2 gas adsorption (N2GA) are performed to evaluate pore structure of Chang-7 tight sandstone. Thin section observation, scanning electron microscope, grain size analysis, mineral composition analysis, and porosity measurement are applied to investigate geological control factors of pore structure. Grain size is positively correlated with detrital mineral content and grain size standard deviation while negatively related to clay content. Detrital mineral content and grain size are positively correlated with porosity, pore throat radius and withdrawal efficiency and negatively related to capillary pressure and pore-to-throat size ratio; while interstitial material is negatively correlated with above mentioned factors. Well sorted sediments with high debris usually possess strong compaction resistance to preserve original pores. Although many inter-crystalline pores are produced in clay minerals, this type of pores is not the most important contributor to porosity. Besides this, pore shape determined by N2GA hysteresis loop is consistent with SEM observation on clay inter-crystalline pores while BJH pore volume is positively related with clay content, suggesting N2GA is suitable for describing clay inter-crystalline pores in tight sandstones. PMID:27830731
Effects of coil orientation on the electric field induced by TMS over the hand motor area
NASA Astrophysics Data System (ADS)
Laakso, Ilkka; Hirata, Akimasa; Ugawa, Yoshikazu
2014-01-01
Responses elicited by transcranial magnetic stimulation (TMS) over the hand motor area depend on the position and orientation of the stimulating coil. In this work, we computationally investigate the induced electric field for multiple coil orientations and locations in order to determine which parts of the brain are affected and how the sensitivity of motor cortical activation depends on the direction of the electric field. The finite element method is used for calculating the electric field induced by TMS in two individual anatomical models of the head and brain. The orientation of the coil affects both the strength and depth of penetration of the electric field, and the field strongly depends on the direction of the sulcus, where the target neurons are located. The coil position that gives the strongest electric field in the target cortical region may deviate from the closest scalp location by a distance on the order of 1 cm. Together with previous experimental data, the results support the hypothesis that the cortex is most sensitive to fields oriented perpendicular to the cortical layers, while it is relatively insensitive to fields parallel to them. This has important implications for targeting of TMS. To determine the most effective coil position and orientation, it is essential to consider both biological (the direction of the targeted axons) and physical factors (the strength and direction of the electric field).
NASA Astrophysics Data System (ADS)
Thomas, Siby; Ajith, K. M.; Valsakumar, M. C.
2017-11-01
This work intents to put forth the results of a classical molecular dynamics study to investigate the temperature dependent elastic constants of monolayer hexagonal boron nitride (h-BN) between 100 and 1000 K for the first time using strain fluctuation method. The temperature dependence of out-of-plane fluctuations (ripples) is quantified and is explained using continuum theory of membranes. At low temperatures, negative in-plane thermal expansion is observed and at high temperatures, a transition to positive thermal expansion has been observed due to the presence of thermally excited ripples. The decrease of Young's modulus, bulk modulus, shear modulus and Poisson's ratio with increase in temperature has been analyzed. The thermal rippling in h-BN leads to strong anharmonic behaviour that causes large deviation from the isotropic elasticity. A detailed study shows that the strong thermal rippling in large systems is also responsible for the softening of elastic constants in h-BN. From the determined values of elastic constants and elastic moduli, it has been elucidated that 2D h-BN sheets meet the Born's mechanical stability criterion in the investigated temperature range. The variation of longitudinal and shear velocities with temperature is also calculated from the computed values of elastic constants and elastic moduli.
Guided filter and convolutional network based tracking for infrared dim moving target
NASA Astrophysics Data System (ADS)
Qian, Kun; Zhou, Huixin; Qin, Hanlin; Rong, Shenghui; Zhao, Dong; Du, Juan
2017-09-01
The dim moving target usually submerges in strong noise, and its motion observability is debased by numerous false alarms for low signal-to-noise ratio. A tracking algorithm that integrates the Guided Image Filter (GIF) and the Convolutional neural network (CNN) into the particle filter framework is presented to cope with the uncertainty of dim targets. First, the initial target template is treated as a guidance to filter incoming templates depending on similarities between the guidance and candidate templates. The GIF algorithm utilizes the structure in the guidance and performs as an edge-preserving smoothing operator. Therefore, the guidance helps to preserve the detail of valuable templates and makes inaccurate ones blurry, alleviating the tracking deviation effectively. Besides, the two-layer CNN method is adopted to obtain a powerful appearance representation. Subsequently, a Bayesian classifier is trained with these discriminative yet strong features. Moreover, an adaptive learning factor is introduced to prevent the update of classifier's parameters when a target undergoes sever background. At last, classifier responses of particles are utilized to generate particle importance weights and a re-sample procedure preserves samples according to the weight. In the predication stage, a 2-order transition model considers the target velocity to estimate current position. Experimental results demonstrate that the presented algorithm outperforms several relative algorithms in the accuracy.
Patient Satisfaction With Pharmacist-Led Chronic Disease State Management Programs.
Schuessler, Tyler J; Ruisinger, Janelle F; Hare, Sarah E; Prohaska, Emily S; Melton, Brittany L
2016-10-01
To assess patient satisfaction, perception of self-management, and perception of disease state knowledge with pharmacist-led diabetes and cardiovascular disease state management (DSM) programs. A self-insured chain of grocery store pharmacies in the Kansas City metropolitan area administers pharmacist-led diabetes and cardiovascular DSM programs for eligible employees and dependents. A modified version of the Diabetes Disease State Management Questionnaire was used to assess patient satisfaction with the DSM programs. Demographic information was also collected. Survey items were based on a 5-point Likert scale (1 = strongly disagree and 5 = strongly agree). Patients were eligible to complete the survey if he or she had been in at least 1 DSM program for 6 months. Data were assessed using descriptive statistics and analysis of variance. Across 20 pharmacies, 281 eligible participants were identified, and 46% (n = 128) completed a survey. Means for summed items relating to overall satisfaction (8 items), self-management (5 items), and knowledge (4 items) were 36.6/40 (standard deviation [SD] = 3.9), 20.9/25 (SD = 3.4), and 17.6/20 (SD = 2.1), respectively. Participant comments further indicated that the program and pharmacists are helpful and increase motivation and accountability. Positive patient responses to the program support use of pharmacist-led DSM programs. © The Author(s) 2015.
Improving student learning via mobile phone video content: Evidence from the BridgeIT India project
NASA Astrophysics Data System (ADS)
Wennersten, Matthew; Quraishy, Zubeeda Banu; Velamuri, Malathi
2015-08-01
Past efforts invested in computer-based education technology interventions have generated little evidence of affordable success at scale. This paper presents the results of a mobile phone-based intervention conducted in the Indian states of Andhra Pradesh and Tamil Nadu in 2012-13. The BridgeIT project provided a pool of audio-visual learning materials organised in accordance with a system of syllabi pacing charts. Teachers of Standard 5 and 6 English and Science classes were notified of the availability of new videos via text messages (SMS), which they downloaded onto their phones using an open-source application and showed, with suggested activities, to students on a TV screen using a TV-out cable. In their evaluation of this project, the authors of this paper found that the test scores of children who experienced the intervention improved by 0.36 standard deviations in English and 0.98 standard deviations in Science in Andhra Pradesh, relative to students in similar classrooms who did not experience the intervention. Differences between treatment and control schools in Tamil Nadu were less marked. The intervention was also cost-effective, relative to other computer-based interventions. Based on these results, the authors argue that is possible to use mobile phones to produce a strong positive and statistically significant effect in terms of teaching and learning quality across a large number of classrooms in India at a lower cost per student than past computer-based interventions.
Gamma ray sources observation with the ARGO-YBJ detector
NASA Astrophysics Data System (ADS)
Vernetto, S.; ARGO-YBJ Collaboration
2011-02-01
In this paper we report on the observations of TeV gamma ray sources performed by the air shower detector ARGO-YBJ. The objects studied in this work are the blazar Markarian 421 and the extended galactic source MGROJ1908+06, monitored during ~2 years of operation. Mrk421 has been detected by ARGO-YBJ with a statistical significance of ~11 standard deviations. The observed TeV emission was highly variable, showing large enhancements of the flux during active periods. The study of the spectral behaviour during flares revealed a positive correlation of the hardness with the flux, as already reported in the past by the Whipple telescope, suggesting that this is a long term property of the source. ARGO-YBJ observed a strong correlation between TeV gamma rays and the X-ray flux measured by RXTM/ASM and SWIFT/BAT during the whole period, with a time lag compatible with zero, supporting the one-zone SSC model to describe the emission mechanism. MGROJ1908+06 has been detected by ARGO-YBJ with ~5 standard deviation of significance. From our data the source appears extended and the measured extension is σext = 0.48° --> σext = 0.48° -0.28+0.26 --> -0.28+0.26, in agreement with a previous HESS observation. The average flux is in marginal agreement with that reported by MILAGRO, but significantly higher than that obtained by HESS, suggesting a possible flux variability.
Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A
2015-08-01
To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.
Does Validity Fall from the Sky? Observant Farmers and the Endogeneity of Rainfall
NASA Astrophysics Data System (ADS)
Miller, B. M.
2016-12-01
Weather, particularly rainfall, is a popular source of identifying variation in many areas of empirical economics. Deviations from mean rainfall are commonly used as a source of exogenous and unpredictable variation in household consumption, aggregate consumption, and income. Yet the prevalence of 10-day weather forecasts and longer-range seasonal forecasts enabled by earth observations suggest plenty of information about future weather events is available. This paper posits that farmers observe signals about future rainfall outcomes and respond appropriately. While the idea of short-run weather expectations influencing crop choices has been occasionally speculated, this paper's broad-based empirical evidence of such adaptation is new. Evidence of anticipatory adaptation is found in two data sets on Indian agriculture which are popular both in general and among papers using rainfall for identifying variation. The crop selections of Indian farmers are found to be strongly correlated with the season's upcoming rainfall in an agronomically efficient manner. In years where rainfall is one standard deviation below the mean, the district-wide acreage of sorghum (a relatively drought resistant crop) increases by almost 3%, while the district-wide acreage of rice (a relatively water-intensive crops) decreases by over 1%. The response of farming households from a popular survey of rural villages are larger than the average response of aggregate acreage, consistent with poorer, smaller-scale farmers being more risk averse. This paper also presents a methodology for estimating the impact of income shocks which accounts for the anticipatory adaptation enabled by this information.
Heyland, Mark; Trepczynski, Adam; Duda, Georg N; Zehn, Manfred; Schaser, Klaus-Dieter; Märdian, Sven
2015-12-01
Selection of boundary constraints may influence amount and distribution of loads. The purpose of this study is to analyze the potential of inertia relief and follower load to maintain the effects of musculoskeletal loads even under large deflections in patient specific finite element models of intact or fractured bone compared to empiric boundary constraints which have been shown to lead to physiological displacements and surface strains. The goal is to elucidate the use of boundary conditions in strain analyses of bones. Finite element models of the intact femur and a model of clinically relevant fracture stabilization by locking plate fixation were analyzed with normal walking loading conditions for different boundary conditions, specifically re-balanced loading, inertia relief and follower load. Peak principal cortex surface strains for different boundary conditions are consistent (maximum deviation 13.7%) except for inertia relief without force balancing (maximum deviation 108.4%). Influence of follower load on displacements increases with higher deflection in fracture model (from 3% to 7% for force balanced model). For load balanced models, follower load had only minor influence, though the effect increases strongly with higher deflection. Conventional constraints of fixed nodes in space should be carefully reconsidered because their type and position are challenging to justify and for their potential to introduce relevant non-physiological reaction forces. Inertia relief provides an alternative method which yields physiological strain results. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Method of surface error visualization using laser 3D projection technology
NASA Astrophysics Data System (ADS)
Guo, Lili; Li, Lijuan; Lin, Xuezhu
2017-10-01
In the process of manufacturing large components, such as aerospace, automobile and shipping industry, some important mold or stamped metal plate requires precise forming on the surface, which usually needs to be verified, if necessary, the surface needs to be corrected and reprocessed. In order to make the correction of the machined surface more convenient, this paper proposes a method based on Laser 3D projection system, this method uses the contour form of terrain contour, directly showing the deviation between the actually measured data and the theoretical mathematical model (CAD) on the measured surface. First, measure the machined surface to get the point cloud data and the formation of triangular mesh; secondly, through coordinate transformation, unify the point cloud data to the theoretical model and calculate the three-dimensional deviation, according to the sign (positive or negative) and size of the deviation, use the color deviation band to denote the deviation of three-dimensional; then, use three-dimensional contour lines to draw and represent every coordinates deviation band, creating the projection files; finally, import the projection files into the laser projector, and make the contour line projected to the processed file with 1:1 in the form of a laser beam, compare the Full-color 3D deviation map with the projection graph, then, locate and make quantitative correction to meet the processing precision requirements. It can display the trend of the machined surface deviation clearly.
Using Solution-Focused Intervention for Behavioral Problems in an Inclusive Classroom.
ERIC Educational Resources Information Center
Quigney, Theresa A.; Studer, Jeannine R.
1999-01-01
Solution-focused intervention deviates from using negative labels (angry, aggressive, or shy) to describe misbehaving students, and reframes behavior descriptions more positively. Four steps (goal setting, looking for exceptions, visualizing a new life story, and practicing the desired behaviors) are vital to facilitating positive behavior…
NASA Astrophysics Data System (ADS)
Thieberger, P.; Gassner, D.; Hulsart, R.; Michnoff, R.; Miller, T.; Minty, M.; Sorrell, Z.; Bartnik, A.
2018-04-01
A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.
Thieberger, Peter; Gassner, D.; Hulsart, R.; ...
2018-04-25
Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thieberger, Peter; Gassner, D.; Hulsart, R.
Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less
Thieberger, P; Gassner, D; Hulsart, R; Michnoff, R; Miller, T; Minty, M; Sorrell, Z; Bartnik, A
2018-04-01
A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.
Baumrind, S; Korn, E L; Ben-Bassat, Y; West, E E
1987-01-01
Lateral skull radiographs for a set of 31 human subjects were examined using computer-aided methods in an attempt to quantify modal trends of maxillary remodeling during the mixed dentition and adolescent growth periods. Cumulative changes in position of anterior nasal spine (ANS), posterior nasal spine (PNS), and Point A are reported at annual intervals relative to superimposition on previously placed maxillary metallic implants. This in vivo longitudinal study confirms at a high level of confidence earlier findings by Enlow, Björk, Melsen, and others to the effect that the superior surface of the maxilla remodels downward during the period of growth and development being investigated. However, the inter-individual variability is relatively large, the mean magnitudes of change are relatively small, and the rate of change appears to diminish by 13.5 years. For the 19 subjects for whom data were available for the time interval from 8.5 to 15.5 years, mean downward remodeling at PNS was 2.50 mm with a standard deviation of 2.23 mm. At ANS, corresponding mean value was 1.56 mm with a standard deviation of 2.92 mm. Mean rotation of the ANS-PNS line relative to the implant line was 1.1 degree in the "forward" direction. However, this rotational change was particularly variable with a standard deviation of 4.6 degrees and a range of 11.3 degrees "forward" to 6.7 degrees "backward." The study provides strong evidence that the palate elongates anteroposteriorly mainly by the backward remodeling of structures located posterior to the region in which the implants were placed. There is also evidence that supports the idea of modal resorptive remodeling at ANS and PNS, but here the data are somewhat more equivocal. It appears likely, but not certain, that there are real differences in the modal patterns of remodeling between treated and untreated subjects. Because of problems associated with overfragmentation of the sample, sex differences were not investigated.
NASA Technical Reports Server (NTRS)
Lutz, O
1940-01-01
Using a previously developed method, the boundary process of four-stroke-cycle engines are set up. The results deviate considerably from those obtained under the assumption that the velocity fluctuation is proportional to the cylinder piston motion. The deviation is less at the position of resonance frequencies. By the method developed, the effect of the resonance vibrations on the volumetric efficiency can be demonstrated.
Ergonomic Worksite Analysis of an Army Dental Clinic
1992-08-01
conducted in which duration of hand grip used (power, pinch, retraction, other) and wrist position (ulnar deviation, radial deviation, neutral...DIAGNOSTIC TESTS percent n Nerve Conduction Study 61 11 X-ray of the wrist or hand 38 7 Grip and/or pinch strength 38 7 Dexterity Testing 33 6 Bone Scan 22 4... hand /wrist symptoms. Back and shoulder pain was reported by 53% of the respondents. Psychosocial factors as well as physical risk factors were found to
Kay, Gary G; Schwartz, Howard I; Wingertzahn, Mark A; Jayawardena, Shyamalie; Rosenberg, Russell P
2016-05-01
Next-day residual effects of a nighttime dose of gabapentin 250 mg were evaluated on simulated driving performance in healthy participants in a randomized, placebo-controlled, double-blind, multicenter, four-period crossover study that included diphenhydramine citrate 76 mg and triazolam 0.5 mg. At treatment visits, participants (n = 59) were dosed at ~23:30, went to bed immediately, and awakened 6.5 h postdose for evaluation. The primary endpoint was the standard deviation of lateral position for the 100-km driving scenario. Additional measures of driving, sleepiness, and cognition were included. Study sensitivity was established with triazolam, which demonstrated significant next-day impairment on all driving endpoints, relative to placebo (p < 0.001). Gabapentin demonstrated noninferiority to placebo on standard deviation of lateral position and speed deviation but not for lane excursions. Diphenhydramine citrate demonstrated significant impairment relative to gabapentin and placebo on speed deviation (p < 0.05). Other comparisons were either nonsignificant or statistically ineligible per planned, sequential comparisons. Secondary endpoints for sleepiness and cognitive performance were supportive of these conclusions. Together, these data suggest that low-dose gabapentin had no appreciable next-day effects on simulated driving performance or cognitive functioning. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Coherence Properties of Strongly Interacting Atomic Vapors in Waveguides
2011-12-31
lattice in the mean-field regime [22]. There the goal was to repeat, for our system, the Chirikiov-lzrailev program for Fermi- Pasta -Ulam chain and...define a typical deviation from ergodicity), we introduce a geometric structure— based on the Frobenius or Hilbert-Schmidt inner product—to the space of
Strong Coupling Corrections in Quantum Thermodynamics
NASA Astrophysics Data System (ADS)
Perarnau-Llobet, M.; Wilming, H.; Riera, A.; Gallego, R.; Eisert, J.
2018-03-01
Quantum systems strongly coupled to many-body systems equilibrate to the reduced state of a global thermal state, deviating from the local thermal state of the system as it occurs in the weak-coupling limit. Taking this insight as a starting point, we study the thermodynamics of systems strongly coupled to thermal baths. First, we provide strong-coupling corrections to the second law applicable to general systems in three of its different readings: As a statement of maximal extractable work, on heat dissipation, and bound to the Carnot efficiency. These corrections become relevant for small quantum systems and vanish in first order in the interaction strength. We then move to the question of power of heat engines, obtaining a bound on the power enhancement due to strong coupling. Our results are exemplified on the paradigmatic non-Markovian quantum Brownian motion.
Propagation of rotational Risley-prism-array-based Gaussian beams in turbulent atmosphere
NASA Astrophysics Data System (ADS)
Chen, Feng; Ma, Haotong; Dong, Li; Ren, Ge; Qi, Bo; Tan, Yufeng
2018-03-01
Limited by the size and weight of prism and optical assembling, Rotational Risley-prism-array system is a simple but effective way to realize high power and superior beam quality of deflecting laser output. In this paper, the propagation of the rotational Risley-prism-array-based Gaussian beam array in atmospheric turbulence is studied in detail. An analytical expression for the average intensity distribution at the receiving plane is derived based on nonparaxial ray tracing method and extended Huygens-Fresnel principle. Power in the diffraction-limited bucket is chosen to evaluate beam quality. The effect of deviation angle, propagation distance and intensity of turbulence on beam quality is studied in detail by quantitative simulation. It reveals that with the propagation distance increasing, the intensity distribution gradually evolves from multiple-petal-like shape into the pattern that contains one main-lobe in the center with multiple side-lobes in weak turbulence. The beam quality of rotational Risley-prism-array-based Gaussian beam array with lower deviation angle is better than its counterpart with higher deviation angle when propagating in weak and medium turbulent (i.e. Cn2 < 10-13m-2/3), the beam quality of higher deviation angle arrays degrades faster as the intensity of turbulence gets stronger. In the case of propagating in strong turbulence, the long propagation distance (i.e. z > 10km ) and deviation angle have no influence on beam quality.
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
NASA Astrophysics Data System (ADS)
Schupp, C. A.; McNinch, J. E.; List, J. H.; Farris, A. S.
2002-12-01
The formation and behavior of hotspots, or sections of the beach that exhibit markedly higher shoreline change rates than adjacent regions, are poorly understood. Several hotspots have been identified on the Outer Banks, a developed barrier island in North Carolina. To better understand hotspot dynamics and the potential relationship to the geologic framework in which they occur, the surf zone between Duck and Bodie Island was surveyed in June 2002 as part of a research effort supported by the U.S. Geological Survey and U.S. Army Corps of Engineers. Swath bathymetry, sidescan sonar, and chirp seismic were used to characterize a region 40 km long and1 km wide. Hotspot locations were pinpointed using standard deviation values for shoreline position as determined by monthly SWASH buggy surveys of the mean high water contour between October 1999 and September 2002. Observational data and sidescan images were mapped to delineate regions of surficial sediment distributions, and regions of interest were ground-truthed via grab samples or visual inspection. General kilometer-scale correlation between acoustic backscatter and high shoreline standard deviation is evident. Acoustic returns are uniform in a region of Duck where standard deviation is low, but backscatter is patchy around the Kitty Hawk hotspot, where standard deviation is higher. Based on ground-truthing of an area further north, these patches are believed to be an older ravinement surface of fine sediment. More detailed analyses of the correlation between acoustic data, standard deviation, and hotspot locations will be presented. Future work will include integration of seismic, bathymetric, and sidescan data to better understand the links between sub-bottom geology, temporal changes in surficial sediments, surf-zone sediment budgets, and short-term changes in shoreline position and morphology.
NASA Astrophysics Data System (ADS)
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brock, K; Lee, C; Samuels, S
Purpose: Tools are now available to perform daily dose assessment in radiotherapy, however, guidance is lacking as to when to replan to limit increase in normal tissue dose. This work performs statistical analysis to provide guidance for when adaptive replanning may be necessary for head/neck (HN) patients. Methods: Planning CT and daily kVCBCT images for 50 HN patients treated with VMAT were retrospectively evaluated. Twelve of 50 patients were replanned due to anatomical changes noted over their RT course. Daily dose assessment was performed to calculate the variation between the planned and delivered dose for the 38 patients not replannedmore » and the patients replanned using their delivered plan. In addition, for the replanned patients, the dose that would have been delivered if the plan was not modified was also quantified. Deviations in dose were analyzed before and after replanning, the daily variations in patients who were not replanned assessed, and the predictive power of the deviation after 1, 5, and 15 fractions determined. Results: Dose deviations were significantly reduced following replanning, compared to if the original plan would have been delivered for the entire course. Early deviations were significantly correlated with total deviations (p<0.01). Using the criteria that a 10% increase in the final delivered dose indicates a replan may be needed earlier in the treatment course, the following guidelines can be made with a 90% specificity after the first 5 fractions: deviations of 7% in the mean dose to the inferior constrictors and 5% in the mean dose to the parotid glands and submandibular glands. No significant dose deviations were observed in any patients for the CTV -70Gy (max deviation 4%). Conclusions: A 5–7% increase in mean dose to normal tissues within the first 5 fractions strongly correlate to an overall deviatios in the delivered dose for HN patients. This work is funded in part by NIH 2P01CA059827-16.« less
NASA Astrophysics Data System (ADS)
Oh, Hyoeun; Jhun, Jong-Ghap; Ha, Kyung-Ja; Seo, Kyong-Hwan
2017-05-01
This study investigates the individual effects of the East Atlantic/West Russia (EATL/WRUS) and Western Pacific (WP) teleconnection patterns and their combined effect on the East Asian winter monsoon (EAWM). The contributions of the respective EATL/WRUS and WP teleconnection patterns to the EAWM are revealed by removing the dependence on the Arctic Oscillation (AO) and the El Niño-Southern Oscillation (ENSO) using a linear regression, which are named as N_EATL/WRUS and N_WP, respectively. This is because the EATL/WRUS (WP) is closely linked to the Arctic (tropics) region. A significant increase (decrease) in temperature over East Asia (EA) corresponding to a weak (strong) EAWM is associated with the N_EATL/WRUS and N_WP teleconnection patterns during the positive (negative) phases. In order to examine impacts of these two teleconnections on the EAWM, three types of effects are reconstructed on the basis of ± 0.5 standard deviation: 1) Combined effect, 2) N_EATL/WRUS effect, and 3) N_WP effect. The positive N_EATL/WRUS teleconnection induces to a weakened Siberian High and a shallow EA trough at the mid-troposphere through wave propagation, leading to the weak EAWM. During the positive N_WP pattern, warm air from the tropics flows toward the EA along western flank of an anomalous anticyclone over the North Pacific that is relevant to the meridional shift of the Aleutian Low. When the two mid-latitude teleconnections have the in-phase combination, the increase in temperature over EA appears to be more pronounced than the individual effects by transporting warm air from tropics via strong southeasterly wind anomalies induced by anomalous zonal pressure gradient between the Siberian High and Aleutian Low. Therefore, the impact of the mid-latitude teleconnections on the EAWM becomes robust and linearly superimposed, unlike a nonlinear in-phase combined effect of the AO and ENSO.
NASA Astrophysics Data System (ADS)
Fang, Suping; Wang, Leijie; Liu, Shiqiao; Komori, Masaharu; Kubo, Aizoh
2011-05-01
In measuring form deviation of gear tooth flanks by laser interferometry, the collected interference fringe pattern (IFP) is badly distorted, in the case of shape, relative to the actual tooth flank. Meanwhile, a clear and definite mapping relationship between the collected IFP and the actual tooth flank is indispensable for both transforming phase differences into deviation values and positioning the measurement result on the actual tooth flank. In order to solve these problems, this paper proposes a method using the simulation tooth image as a bridge connecting the actual tooth flank and the collected IFP. The mapping relationship between the simulation tooth image and the actual tooth flank has been obtained by ray tracing methods [Fang et al., Appl. Opt. 49(33), 6409-6415 (2010)]. This paper mainly discusses how to build the relationship between the simulation tooth image and the collected IFP by using a matching algorithm of two characteristic point sets. With the combination of the two above-mentioned assistant mapping relationships, the mapping relationship between the collected IFP and the actual tooth flank can be built; the collected IFP can be positioned on the actual tooth flank. Finally, the proposed method is employed in a measurement of the form deviation of a gear tooth flank and the result proves the feasibility of the proposed method.
How does cryotherapy effect ankle proprioception in healthy individuals?
Houten, Daniel; Cooper, Darren
2017-09-01
Objectives To investigate how a 15-min cryotherapy intervention effects proprioception by measuring joint positional sense (JPS) and static single legged balance. Design Repeated measures design. Setting Laboratory. Participants Eighteen healthy university sports team students (11 males, 7 females) aged between 20 and 21 years old. Main outcome measures Participants were treated with 15 min of Aircast Cryo-cuff. The subject's skin temperature was measured before and immediately after 15 min of cryotherapy treatment. Ankle active joint positional sense (A-JPS) and passive joint positional sense (P-JPS) were measured at pre-test, immediately post-test, and 5 min post-test. Static balance was measured by centre of pressure (CoP) mean path length, medial-lateral (ML) CoP mean deviation, and anterior-posterior (AP) CoP mean deviation and mean time-to-boundary (TtB) minima for AP and ML directions. Results No significant differences were found for the variables of JPS and static single balance testing after 15 min of cryotherapy treatment. However, mean differences for CoP mean path length and ML mean deviation were shown to improve following cryotherapy treatment, results not previously found in the literature. Conclusion Results suggest that 15 min of Cryo-cuff treatment does not significantly affect proprioception. Although the effect of cryotherapy on proprioception depends on cooling modality used, time frame applied, and joint applied to.
NASA Astrophysics Data System (ADS)
Hou, M.; Liu, R.; Li, Y.; Lu, K.; Garrabos, Y.; Evesque, P.
2009-06-01
Dynamics of quasi-2d dissipative granular gas is studied in microgravity condition (of the order of 10-4 g) in the limit of Knudsen regime. The gas, made of 4 spheres, is confined in a square cell enforced to follow linear sinusoidal vibration in ten different vibration modes. The trajectory of one of the particles is tracked and reconstructed from the 2-hour video data. From statistical analysis, we find that (i) loss due to wall friction is small, (ii) trajectory looks ergodic in space, and (iii) distribution ρ(v) of speed follows an exponential distribution, i.e. ρ(v)≈exp(-v/vxo,yo), with vxo,yo being a characteristic velocity along a direction parallel (y) or perpendicular (x) to vibration direction. This law deviates strongly from the Boltzmann distribution of speed in molecular gas. Comparisons of this result with previous measurements in earth environment, and what was found in 3d cell [1] performed in 10-2 g environment are given.
Zhang, Hong; Wang, Chenchen; Li, Huidong; Nie, Yan; Fang, Liping; Chen, Zilei
2018-03-01
Two polar aminoglycosides, kasugamycin and validamycin-A, were determined in cereals (brown rice, wheat and corn) by high-performance liquid chromatography-tandem mass spectrometry. The analytes were extracted from samples using methanol and water (70:30, v/v) at pH 5.5, purified using both a hydrophilic-hydrophobic-balanced cartridge and a strong cation-exchange cartridge, and then analysed using multiple reaction monitoring in positive electrospray ionisation mode with a special ReproSil 100 C 18 high-performance liquid chromatography column. This newly proposed method yielded good sensitivity and excellent chromatographic performance. The limits of quantification for kasugamycin and validamycin-A were 4.1 µg/kg and 1.0 µg/kg, respectively. The recoveries for both compounds at three fortification levels (4, 100 and 500 µg/kg for kasugamycin; 1, 10 and 100 µg/kg for validamycin-A) ranged from 75% to 110%, and the relative standard deviations were below 15%.
Madison, Guy; Gouyon, Fabien; Ullén, Fredrik; Hörnström, Kalle
2011-10-01
Groove is often described as the experience of music that makes people tap their feet and want to dance. A high degree of consistency in ratings of groove across listeners indicates that physical properties of the sound signal contribute to groove (Madison, 2006). Here, correlations were assessed between listeners' ratings and a number of quantitative descriptors of rhythmic properties for one hundred music examples from five distinct traditional music genres. Groove was related to several different rhythmic properties, some of which were genre-specific and some of which were general across genres. Two descriptors corresponding to the density of events between beats and the salience of the beat, respectively, were strongly correlated with groove across domains. In contrast, systematic deviations from strict positions on the metrical grid, so-called microtiming, did not play any significant role. The results are discussed from a functional perspective of rhythmic music to enable and facilitate entrainment and precise synchronization among individuals.
Fjermestad, K W; Lerner, M D; McLeod, B D; Wergeland, G J H; Haugland, B S M; Havik, O E; Öst, L-G; Silverman, W K
2017-11-16
We examined whether motivation and treatment credibility predicted alliance in a 10-session cognitive behavioral treatment delivered in community clinics for youth anxiety disorders. Ninety-one clinic-referred youths (mean age = 11.4 years, standard deviation = 2.1, range 8-15 years, 49.5% boys) with anxiety disorders-rated treatment motivation at pretreatment and perceived treatment credibility after session 1. Youths and therapists (YT) rated alliance after session 3 (early) and session 7 (late). Hierarchical linear models were applied to examine whether motivation and treatment credibility predicted YT early alliance, YT alliance change, and YT alliance agreement. Motivation predicted high early YT alliance, but not YT alliance change or alliance agreement. Youth-rated treatment credibility predicted high early youth alliance and high YT positive alliance change, but not early therapist alliance or alliance agreement. Conclusion Efforts to enhance youth motivation and treatment credibility early in treatment could facilitate the formation of a strong YT alliance. © 2017 Wiley Periodicals, Inc.
Negative Pressure Vitrification of the Isochorically Confined Liquid in Nanopores.
Adrjanowicz, K; Kaminski, K; Koperwas, K; Paluch, M
2015-12-31
Dielectric relaxation studies for model glass-forming liquids confined to nanoporous alumina matrices were examined together with high-pressure results. For confined liquids which show the deviation from bulk dynamics upon approaching the glass transition (the change from the Vogel-Fulcher-Tammann to the Arrhenius law), we have observed a striking agreement between the temperature dependence of the α-relaxation time in the Arrhenius-like region and the isochoric relaxation times extrapolated from the positive range of pressure to the negative pressure domain. Our finding provides strong evidence that glass-forming liquid confined to native nanopores enters the isochoric conditions once the mobility of the interfacial layer becomes frozen in. This results in the negative pressure effects on cooling. We also demonstrate that differences in the sensitivity of various glass-forming liquids to the "confinement effects" can be rationalized by considering the relative importance of thermal energy and density contributions in controlling the α-relaxation dynamics (the E(v)/E(p) ratio).
NASA Astrophysics Data System (ADS)
Becker, Leif E.; Shelley, Michael J.
2000-11-01
First normal stress differences in shear flow are a fundamental property of Non-Newtonian fluids. Experiments involving dilute suspensions of slender fibers exhibit a sharp transition to non-zero normal stress differences beyond a critical shear rate, but existing continuum theories for rigid rods predict neither this transition nor the corresponding magnitude of this effect. We present the first conclusive evidence that elastic instabilities are predominantly responsible for observed deviations from the dilute suspension theory of rigid rods. Our analysis is based on slender body theory and the equilibrium equations of elastica. A straight slender body executing its Jeffery orbit in Couette flow is subject to axial fluid forcing, alternating between compression and tension. We present a stability analysis showing that elastic instabilities are possible for strong flows. Simulations give the fully non-linear evolution of this shape instability, and show that flexibility of the fibers alone is sufficient to cause both shear-thinning and significant first normal stress differences.
Spatial and numerical processing in children with high and low visuospatial abilities.
Crollen, Virginie; Noël, Marie-Pascale
2015-04-01
In the literature on numerical cognition, a strong association between numbers and space has been repeatedly demonstrated. However, only a few recent studies have been devoted to examine the consequences of low visuospatial abilities on calculation processing. In this study, we wanted to investigate whether visuospatial weakness may affect pure spatial processing as well as basic numerical reasoning. To do so, the performances of children with high and low visuospatial abilities were directly compared on different spatial tasks (the line bisection and Simon tasks) and numerical tasks (the number bisection, number-to-position, and numerical comparison tasks). Children from the low visuospatial group presented the classic Simon and SNARC (spatial numerical association of response codes) effects but showed larger deviation errors as compared with the high visuospatial group. Our results, therefore, demonstrated that low visuospatial abilities did not change the nature of the mental number line but rather led to a decrease in its accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.
Physics at the surface of a star in Eddington-inspired Born-Infeld Gravity
NASA Astrophysics Data System (ADS)
Kim, Hyeong-Chan
2014-03-01
We study phenomena happening at the surface of a star in Eddington-inspired Born-Infeld (EiBI) gravity. The star is made of particles, which are effectively described by a polytropic fluid. The EiBI theory was known to have a pathology that singularities happen at a star surface. We suggest that the gravitational backreaction on the particles cures the problem. Strong tidal forces near the (surface) singularity modify the effective equation of state of the particles or make the surface be unstable depending on its matter contents. The geodesic deviation equations take after Hooke's law, where its frequency squared is proportional to the scalar curvature at the surface. For a positive curvature, a particle collides with a probing wall more often and increases the pressure. With the increased pressure, the surface is no longer singular. For a negative curvature, the matters around the surface experience repulsions with infinite accelerations. Therefore, the EiBI gravity is saved from the pathology of a surface singularity.
Manzi, Aurora; Tong, Yu; Feucht, Julius; Yao, En-Ping; Polavarapu, Lakshminarayana; Urban, Alexander S; Feldmann, Jochen
2018-04-17
Multi-photon absorption and multiple exciton generation represent two separate strategies for enhancing the conversion efficiency of light into usable electric power. Targeting below-band-gap and above-band-gap energies, respectively, to date these processes have only been demonstrated independently. Here we report the combined interaction of both nonlinear processes in CsPbBr 3 perovskite nanocrystals. We demonstrate nonlinear absorption over a wide range of below-band-gap excitation energies (0.5-0.8 E g ). Interestingly, we discover high-order absorption processes, deviating from the typical two-photon absorption, at specific energetic positions. These energies are associated with a strong enhancement of the photoluminescence intensity by up to 10 5 . The analysis of the corresponding energy levels reveals that the observed phenomena can be ascribed to the resonant creation of multiple excitons via the absorption of multiple below-band-gap photons. This effect may open new pathways for the efficient conversion of optical energy, potentially also in other semiconducting materials.
NASA Astrophysics Data System (ADS)
Speck, Thomas; Engel, Andreas; Seifert, Udo
2012-12-01
We study the large deviation function for the entropy production rate in two driven one-dimensional systems: the asymmetric random walk on a discrete lattice and Brownian motion in a continuous periodic potential. We compare two approaches: using the Donsker-Varadhan theory and using the Freidlin-Wentzell theory. We show that the wings of the large deviation function are dominated by a single optimal trajectory: either in the forward direction (positive rate) or in the backward direction (negative rate). The joining of the two branches at zero entropy production implies a non-differentiability and thus the appearance of a ‘kink’. However, around zero entropy production, many trajectories contribute and thus the ‘kink’ is smeared out.
Welding wire pressure sensor assembly
NASA Technical Reports Server (NTRS)
Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)
1994-01-01
The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.
NASA Technical Reports Server (NTRS)
Clark, P. E.; Andre, C. G.; Adler, I.; Weidner, J.; Podwysocki, M.
1976-01-01
The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.
Extreme Right Axis Deviation in Acute Myocardial Infarction: A Hazardous Signal of Poor Prognosis.
Wang, Qingyu; Pan, Shuo; Liu, Fuqiang; Yang, Dan; Wang, Jun-Kui
2018-05-11
BACKGROUND New-onset extreme right axis deviation and right bundle branch block (RBBB) are rare during acute myocardial infarction (AMI), and has only been reported in several cases reflecting the severity of AMI. It could predict severe clinical complications and higher risks in coronary artery disease. Although there is little electrophysiological explanation, the complications are severe. They should be emphasized in newly diagnosed extreme right axis deviation and RBBB in AMI. CASE REPORT A 72-year-old male was admitted to our department with a chief complaint of intermittent retrosternal chest pain and was diagnosed with extensive anterior myocardial infarction with RBBB, by elevated myocardial enzymes and ECG. The main wave direction of QRS in lead aVR was positive and showed an extreme right axis deviation. After a month, the patient's chest distress and the RBBB vanished, but a right axis deviation still existed. The echocardiogram showed prior extensive anterior myocardial infarction (including apex myocardia) and lower LVEF. CONCLUSIONS New diagnosed RBBB and right axis deviation is uncommon and could be a useful clue to evaluate myocardial ischemia in AMI cases. This electrocardiographic marker can identify coronary artery occlusion where ST-segments are hard to evaluate, and hence, patients may benefit most from early and complete revascularization strategies such as primary angioplasty.
Optical Tracker For Longwall Coal Shearer
NASA Technical Reports Server (NTRS)
Poulsen, Peter D.; Stein, Richard J.; Pease, Robert E.
1989-01-01
Photographic record yields information for correction of vehicle path. Tracking system records lateral movements of longwall coal-shearing vehicle. System detects lateral and vertical deviations of path of vehicle moving along coal face, shearing coal as it goes. Rides on rails in mine tunnel, advancing on toothed track in one of rails. As vehicle moves, retroreflective mirror rides up and down on teeth, providing series of pulsed reflections to film recorder. Recorded positions of pulses, having horizontal and vertical orientations, indicate vertical and horizontal deviations, respectively, of vehicle.
Agent-Based Computing in Distributed Adversarial Planning
2010-08-09
plans. An agent is expected to agree to deviate from its optimal uncoordinated plan only if it improves its position. - process models for opponent...Game . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.2 Improvements ...plan only if it improves its position. – process models for opponent modeling – We have analyzed the suitability of business process models for creating
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J; Murtha, Michael T; Hus, Vanessa; Lowe, Jennifer K; Willsey, A Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E; Ledbetter, David H; Lord, Catherine; Mane, Shrikant M; Lese Martin, Christa; Martin, Donna M; Morrow, Eric M; Walsh, Christopher A; Sutcliffe, James S; State, Matthew W; Devlin, Bernie; Cook, Edwin H; Kim, Soo-Jeong
2013-10-15
Brain development follows a different trajectory in children with autism spectrum disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. Gender, age, height, weight, genetic ancestry, and ASD status were significant predictors of HC (estimate of the ASD effect = .2 cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait, and population norms for HC would be far more accurate if covariates including genetic ancestry, height, and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. © 2013 Society of Biological Psychiatry.
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J.; Murtha, Michael T.; Hus, Vanessa; Lowe, Jennifer K.; Willsey, A. Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W.; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E.; Ledbetter, David H.; Lord, Catherine; Mane, Shrikant M.; Martin, Christa Lese; Martin, Donna M.; Morrow, Eric M.; Walsh, Christopher A.; Sutcliffe, James S.; State, Matthew W.; Devlin, Bernie; Cook, Edwin H.; Kim, Soo-Jeong
2013-01-01
BACKGROUND Brain development follows a different trajectory in children with Autism Spectrum Disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. METHODS We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. RESULTS Gender, age, height, weight, genetic ancestry and ASD status were significant predictors of HC (estimate of the ASD effect=0.2cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. CONCLUSIONS Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait and population norms for HC would be far more accurate if covariates including genetic ancestry, height and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. PMID:23746936
Unveiling the Dependence of Glass Transitions on Mixing Thermodynamics in Miscible Systems
NASA Astrophysics Data System (ADS)
Tu, Wenkang; Wang, Yunxi; Li, Xin; Zhang, Peng; Tian, Yongjun; Jin, Shaohua; Wang, Li-Min
2015-02-01
The dependence of the glass transition in mixtures on mixing thermodynamics is examined by focusing on enthalpy of mixing, ΔHmix with the change in sign (positive vs. negative) and magnitude (small vs. large). The effects of positive and negative ΔHmix are demonstrated based on two isomeric systems of o- vs. m- methoxymethylbenzene (MMB) and o- vs. m- dibromobenzene (DBB) with comparably small absolute ΔHmix. Two opposite composition dependences of the glass transition temperature, Tg, are observed with the MMB mixtures showing a distinct negative deviation from the ideal mixing rule and the DBB mixtures having a marginally positive deviation. The system of 1, 2- propanediamine (12PDA) vs. propylene glycol (PG) with large and negative ΔHmix is compared with the systems of small ΔHmix, and a considerably positive Tg shift is seen. Models involving the properties of pure components such as Tg, glass transition heat capacity increment, ΔCp, and density, ρ, do not interpret the observed Tg shifts in the systems. In contrast, a linear correlation is revealed between ΔHmix and maximum Tg shifts.
Acoustic differences between humorous and sincere communicative intentions.
Hoicka, Elena; Gattis, Merideth
2012-11-01
Previous studies indicate that the acoustic features of speech discriminate between positive and negative communicative intentions, such as approval and prohibition. Two studies investigated whether acoustic features of speech can discriminate between two positive communicative intentions: humour and sweet-sincerity, where sweet-sincerity involved being sincere in a positive, warm-hearted way. In Study 1, 22 mothers read a book containing humorous, sweet-sincere, and neutral-sincere images to their 19- to 24-month-olds. In Study 2, 41 mothers read a book containing humorous or sweet-sincere sentences and images to their 18- to 24-month-olds. Mothers used a higher mean F0 to communicate visual humour as compared to visual sincerity. Mothers used greater F0 mean, range, and standard deviation; greater intensity mean, range, and standard deviation; and a slower speech rate to communicate verbal humour as compared to verbal sweet-sincerity. Mothers used a rising linear contour to communicate verbal humour, but used no specific contour to express verbal sweet-sincerity. We conclude that speakers provide acoustic cues enabling listeners to distinguish between positive communicative intentions. ©2011 The British Psychological Society.
INFLUENCE OF THE GALACTIC GRAVITATIONAL FIELD ON THE POSITIONAL ACCURACY OF EXTRAGALACTIC SOURCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larchenkova, Tatiana I.; Lutovinov, Alexander A.; Lyskova, Natalya S.
We investigate the influence of random variations of the Galactic gravitational field on the apparent celestial positions of extragalactic sources. The basic statistical characteristics of a stochastic process (first-order moments, an autocorrelation function and a power spectral density) are used to describe a light ray deflection in a gravitational field of randomly moving point masses as a function of the source coordinates. We map a 2D distribution of the standard deviation of the angular shifts in positions of distant sources (including reference sources of the International Celestial Reference Frame) with respect to their true positions. For different Galactic matter distributionsmore » the standard deviation of the offset angle can reach several tens of μ as (microarcsecond) toward the Galactic center, decreasing down to 4–6 μ as at high galactic latitudes. The conditional standard deviation (“jitter”) of 2.5 μ as is reached within 10 years at high galactic latitudes and within a few months toward the inner part of the Galaxy. The photometric microlensing events are not expected to be disturbed by astrometric random variations anywhere except the inner part of the Galaxy as the Einstein–Chvolson times are typically much shorter than the jittering timescale. While a jitter of a single reference source can be up to dozens of μ as over some reasonable observational time, using a sample of reference sources would reduce the error in relative astrometry. The obtained results can be used for estimating the physical upper limits on the time-dependent accuracy of astrometric measurements.« less
Unification of small and large time scales for biological evolution: deviations from power law.
Chowdhury, Debashish; Stauffer, Dietrich; Kunwar, Ambarish
2003-02-14
We develop a unified model that describes both "micro" and "macro" evolutions within a single theoretical framework. The ecosystem is described as a dynamic network; the population dynamics at each node of this network describes the "microevolution" over ecological time scales (i.e., birth, ageing, and natural death of individual organisms), while the appearance of new nodes, the slow changes of the links, and the disappearance of existing nodes accounts for the "macroevolution" over geological time scales (i.e., the origination, evolution, and extinction of species). In contrast to several earlier claims in the literature, we observe strong deviations from power law in the regime of long lifetimes.
Simulations of fill tube effects on the implosion of high-foot NIF ignition capsules
NASA Astrophysics Data System (ADS)
Dittrich, T. R.; Hurricane, O. A.; Berzak-Hopkins, L. F.; Callahan, D. A.; Casey, D. T.; Clark, D.; Dewald, E. L.; Doeppner, T.; Haan, S. W.; Hammel, B. A.; Harte, J. A.; Hinkel, D. E.; Kozioziemski, B. J.; Kritcher, A. L.; Ma, T.; Nikroo, A.; Pak, A. E.; Parham, T. G.; Park, H.-S.; Patel, P. K.; Remington, B. A.; Salmonson, J. D.; Springer, P. T.; Weber, C. R.; Zimmerman, G. B.; Kline, J. L.
2016-05-01
Encouraging results have been obtained using a strong first shock during the implosion of carbon-based ablator ignition capsules. These “high-foot” implosion results show that capsule performance deviates from 1D expectations as laser power and energy are increased. A possible cause of this deviation is the disruption of the hot spot by jets originating in the capsule fill tube. Nominally, a 10 μm outside diameter glass (SiO2) fill tube is used in these implosions. Simulations indicate that a thin coating of Au on this glass tube may lessen the hotspot disruption. These results and other mitigation strategies will be presented.
Current from a nano-gap hyperbolic diode using shape-factors: Theory
NASA Astrophysics Data System (ADS)
Jensen, Kevin L.; Shiffler, Donald A.; Peckerar, Martin; Harris, John R.; Petillo, John J.
2017-08-01
Quantum tunneling by field emission from nanoscale features or sharp field emission structures for which the anode-cathode gap is nanometers in scale ("nano diodes") experience strong deviations from the planar image charge lowered tunneling barrier used in the Murphy and Good formulation of the Fowler-Nordheim equation. These deviations alter the prediction of total current from a curved surface. Modifications to the emission barrier are modeled using a hyperbolic (prolate spheroidal) geometry to determine the trajectories along which the Gamow factor in a WKB-like treatment is undertaken; a quadratic equivalent potential is determined, and a method of shape factors is used to evaluate the corrected total current from a protrusion or wedge geometry.
Results of the eruptive column model inter-comparison study
Costa, Antonio; Suzuki, Yujiro; Cerminara, M.; Devenish, Ben J.; Esposti Ongaro, T.; Herzog, Michael; Van Eaton, Alexa; Denby, L.C.; Bursik, Marcus; de' Michieli Vitturi, Mattia; Engwell, S.; Neri, Augusto; Barsotti, Sara; Folch, Arnau; Macedonio, Giovanni; Girault, F.; Carazzo, G.; Tait, S.; Kaminski, E.; Mastin, Larry G.; Woodhouse, Mark J.; Phillips, Jeremy C.; Hogg, Andrew J.; Degruyter, Wim; Bonadonna, Costanza
2016-01-01
This study compares and evaluates one-dimensional (1D) and three-dimensional (3D) numerical models of volcanic eruption columns in a set of different inter-comparison exercises. The exercises were designed as a blind test in which a set of common input parameters was given for two reference eruptions, representing a strong and a weak eruption column under different meteorological conditions. Comparing the results of the different models allows us to evaluate their capabilities and target areas for future improvement. Despite their different formulations, the 1D and 3D models provide reasonably consistent predictions of some of the key global descriptors of the volcanic plumes. Variability in plume height, estimated from the standard deviation of model predictions, is within ~ 20% for the weak plume and ~ 10% for the strong plume. Predictions of neutral buoyancy level are also in reasonably good agreement among the different models, with a standard deviation ranging from 9 to 19% (the latter for the weak plume in a windy atmosphere). Overall, these discrepancies are in the range of observational uncertainty of column height. However, there are important differences amongst models in terms of local properties along the plume axis, particularly for the strong plume. Our analysis suggests that the simplified treatment of entrainment in 1D models is adequate to resolve the general behaviour of the weak plume. However, it is inadequate to capture complex features of the strong plume, such as large vortices, partial column collapse, or gravitational fountaining that strongly enhance entrainment in the lower atmosphere. We conclude that there is a need to more accurately quantify entrainment rates, improve the representation of plume radius, and incorporate the effects of column instability in future versions of 1D volcanic plume models.
Nevinny-Stickel, Meinhard; Sweeney, Reinhart A; Bale, Reto J; Posch, Andrea; Auberger, Thomas; Lukas, Peter
2004-02-01
Precise reproducible patient positioning is a prerequisite for conformal fractionated radiotherapy. A fixation system based on double-vacuum technology is presented which can be used for conventional as well as hypofractionated stereotactic extracranial radiotherapy. To form the actual vacuum mattress, the patient is pressed into the mattress with a vacuum foil which can also be used for daily repositioning and fixation. A stereotactic frame can be positioned over the region of interest on an indexed base plate. Repositioning accuracy was determined by comparing daily, pretreatment, orthogonal portal images to the respective digitally reconstructed radiographs (DRRs) in ten patients with abdominal and pelvic lesions receiving extracranial fractionated (stereotactic) radiotherapy. The three-dimensional (3-D) vectors and 95% confidence intervals (CI) were calculated from the respective deviations in the three axes. Time required for initial mold production and daily repositioning was also determined. The mean 3-D repositioning error (187 fractions) was 2.5 +/- 1.1 mm. The largest single deviation (10 mm) was observed in a patient treated in prone position. Mold production took an average of 15 min (10-30 min). Repositioning times are not necessarily longer than using no positioning aid at all. The presented fixation system allows reliable, flexible and efficient patient positioning for extracranial stereotactic radiotherapy.
Thermal convection of liquid metal in a long inclined cylinder
NASA Astrophysics Data System (ADS)
Teimurazov, Andrei; Frick, Peter
2017-11-01
The turbulent convection of low-Prandtl-number fluids (Pr=0.0083 ) in a long cylindrical cell, heated at one end face and cooled at the other, inclined to the vertical at angle β , 0 ≤β ≤π /2 with step π /20 , is studied numerically by solving the Oberbeck-Boussinesq equations with the large-eddy-simulation approach for small-scale turbulence. The cylinder length is L =5 D , where D is the diameter. The Rayleigh number, determined by the cylinder diameter, is of the order of 5 ×106 . We show that the structure of the flow strongly depends on the inclination angle. A stable large-scale circulation (LSC) slightly disturbed by small-scale turbulence exists in the horizontal cylinder. The deviation from a horizontal position provides strong amplification of both LSC and small-scale turbulence. The energy of turbulent pulsations increases monotonically with decreasing inclination angle β , matching the energy of the LSC at β ≈π /5 . The intensity of the LSC has a wide, almost flat, maximum for an inclined cylinder and slumps approaching the vertical position, in which the LSC vanishes. The dependence of the Nusselt number on the inclination angle has a maximum at β ≈7 π /20 and generally follows the dependence of the intensity of LSC on the inclination. This indicates that the total heat transport is highly determined by LSC. We examine the applicability of idealized thermal boundary conditions (BCs) for modeling a real experiment with liquid sodium flows. Therefore, the simulations are done with two types of temperature BCs: fixed face temperature and fixed heat flux. The intensity of the LSC is slightly higher in the latter case and leads to a corresponding increase of the Nusselt number and enhancement of temperature pulsations.
Reconciling Intuitive Physics and Newtonian Mechanics for Colliding Objects
ERIC Educational Resources Information Center
Sanborn, Adam N.; Mansinghka, Vikash K.; Griffiths, Thomas L.
2013-01-01
People have strong intuitions about the influence objects exert upon one another when they collide. Because people's judgments appear to deviate from Newtonian mechanics, psychologists have suggested that people depend on a variety of task-specific heuristics. This leaves open the question of how these heuristics could be chosen, and how to…
A Monte Carlo Approach to Unidimensionality Testing in Polytomous Rasch Models
ERIC Educational Resources Information Center
Christensen, Karl Bang; Kreiner, Svend
2007-01-01
Many statistical tests are designed to test the different assumptions of the Rasch model, but only few are directed at detecting multidimensionality. The Martin-Lof test is an attractive approach, the disadvantage being that its null distribution deviates strongly from the asymptotic chi-square distribution for most realistic sample sizes. A Monte…
Red, Straight, no bends: primordial power spectrum reconstruction from CMB and large-scale structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ravenni, Andrea; Verde, Licia; Cuesta, Antonio J., E-mail: andrea.ravenni@pd.infn.it, E-mail: liciaverde@icc.ub.edu, E-mail: ajcuesta@icc.ub.edu
2016-08-01
We present a minimally parametric, model independent reconstruction of the shape of the primordial power spectrum. Our smoothing spline technique is well-suited to search for smooth features such as deviations from scale invariance, and deviations from a power law such as running of the spectral index or small-scale power suppression. We use a comprehensive set of the state-of the art cosmological data: Planck observations of the temperature and polarisation anisotropies of the cosmic microwave background, WiggleZ and Sloan Digital Sky Survey Data Release 7 galaxy power spectra and the Canada-France-Hawaii Lensing Survey correlation function. This reconstruction strongly supports the evidencemore » for a power law primordial power spectrum with a red tilt and disfavours deviations from a power law power spectrum including small-scale power suppression such as that induced by significantly massive neutrinos. This offers a powerful confirmation of the inflationary paradigm, justifying the adoption of the inflationary prior in cosmological analyses.« less
Red, Straight, no bends: primordial power spectrum reconstruction from CMB and large-scale structure
NASA Astrophysics Data System (ADS)
Ravenni, Andrea; Verde, Licia; Cuesta, Antonio J.
2016-08-01
We present a minimally parametric, model independent reconstruction of the shape of the primordial power spectrum. Our smoothing spline technique is well-suited to search for smooth features such as deviations from scale invariance, and deviations from a power law such as running of the spectral index or small-scale power suppression. We use a comprehensive set of the state-of the art cosmological data: Planck observations of the temperature and polarisation anisotropies of the cosmic microwave background, WiggleZ and Sloan Digital Sky Survey Data Release 7 galaxy power spectra and the Canada-France-Hawaii Lensing Survey correlation function. This reconstruction strongly supports the evidence for a power law primordial power spectrum with a red tilt and disfavours deviations from a power law power spectrum including small-scale power suppression such as that induced by significantly massive neutrinos. This offers a powerful confirmation of the inflationary paradigm, justifying the adoption of the inflationary prior in cosmological analyses.
Age-independent anti-Müllerian hormone (AMH) standard deviation scores to estimate ovarian function.
Helden, Josef van; Weiskirchen, Ralf
2017-06-01
To determine single year age-specific anti-Müllerian hormone (AMH) standard deviation scores (SDS) for women associated to normal ovarian function and different ovarian disorders resulting in sub- or infertility. Determination of particular year median and mean AMH values with standard deviations (SD), calculation of age-independent cut off SDS for the discrimination between normal ovarian function and ovarian disorders. Single-year-specific median, mean, and SD values have been evaluated for the Beckman Access AMH immunoassay. While the decrease of both median and mean AMH values is strongly correlated with increasing age, calculated SDS values have been shown to be age independent with the differentiation between normal ovarian function measured as occurred ovulation with sufficient luteal activity compared with hyperandrogenemic cycle disorders or anovulation associated with high AMH values and reduced ovarian activity or insufficiency associated with low AMH, respectively. These results will be helpful for the treatment of patients and the ventilation of the different reproductive options. Copyright © 2017 Elsevier B.V. All rights reserved.
Multipole moments of bumpy black holes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vigeland, Sarah J.
General relativity predicts the existence of black holes, compact objects whose spacetimes depend only on their mass, spin, and charge in vacuum (the 'no-hair' theorem). As various observations probe deeper into the strong fields of black hole candidates, it is becoming possible to test this prediction. Previous work suggested that such tests can be performed by measuring whether the multipolar structure of black hole candidates has the form that general relativity demands, and introduced a family of 'bumpy black hole' spacetimes to be used for making these measurements. These spacetimes have generalized multipoles, where the deviation from the Kerr metricmore » depends on the spacetime's 'bumpiness'. In this paper, we show how to compute the Geroch-Hansen moments of a bumpy black hole, demonstrating that there is a clean mapping between the deviations used in the bumpy black hole formalism and the Geroch-Hansen moments. We also extend our previous results to define bumpy black holes whose current moments, analogous to magnetic moments of electrodynamics, deviate from the canonical Kerr value.« less
Large deviations and mixing for dissipative PDEs with unbounded random kicks
NASA Astrophysics Data System (ADS)
Jakšić, V.; Nersesyan, V.; Pillet, C.-A.; Shirikyan, A.
2018-02-01
We study the problem of exponential mixing and large deviations for discrete-time Markov processes associated with a class of random dynamical systems. Under some dissipativity and regularisation hypotheses for the underlying deterministic dynamics and a non-degeneracy condition for the driving random force, we discuss the existence and uniqueness of a stationary measure and its exponential stability in the Kantorovich-Wasserstein metric. We next turn to the large deviations principle (LDP) and establish its validity for the occupation measures of the Markov processes in question. The proof is based on Kifer’s criterion for non-compact spaces, a result on large-time asymptotics for generalised Markov semigroup, and a coupling argument. These tools combined together constitute a new approach to LDP for infinite-dimensional processes without strong Feller property in a non-compact space. The results obtained can be applied to the two-dimensional Navier-Stokes system in a bounded domain and to the complex Ginzburg-Landau equation.
Structure-property relations of orthorhombic [(CH3)3NCH2COO]2(CuCl2)3 · 2H2 O
NASA Astrophysics Data System (ADS)
Haussühl, Eiken; Schreuer, Jürgen; Wiehl, Leonore; Paulsen, Natalia
2014-04-01
Large single crystals of orthorhombic [(CH3)3NCH2COO]2(CuCl2)3 · 2H2 O with dimensions up to 40×40×30 mm3 were grown from aqueous solutions. The elastic and piezoelastic coefficients were derived from ultrasonic resonance frequencies and their shifts upon variation of pressure, respectively, using the plate-resonance technique. Additionally, the coefficients of thermal expansion were determined between 95 K and 305 K by dilatometry. The elastic behaviour at ambient conditions is dominated by the 2-dimensional network of strong hydrogen bonds within the (001) plane leading to a corresponding pseudo-tetragonal anisotropy of the longitudinal elastic stiffness. The variation of elastic properties with pressure, however, as well as the thermal expansion shows strong deviations from the pseudo-tetragonal symmetry. These deviations are probably correlated with tilts of the elongated tri-nuclear betaine-CuCl2-water complexes. Neither the thermal expansion nor the specific heat capacity gives any hint on a phase transition in the investigated temperature range.
Early Emission from Type Ia Supernovae
NASA Astrophysics Data System (ADS)
Rabinak, Itay; Livne, Eli; Waxman, Eli
2012-09-01
A unique feature of deflagration-to-detonation (DDT) white dwarf explosion models of supernovae of type Ia is the presence of a strong shock wave propagating through the outer envelope. We consider the early emission expected in such models, which is produced by the expanding shock-heated outer part of the ejecta and precedes the emission driven by radioactive decay. We expand on earlier analyses by considering the modification of the pre-detonation density profile by the weak shocks generated during the deflagration phase, the time evolution of the opacity, and the deviation of the post-shock equation of state from that obtained for radiation pressure domination. A simple analytic model is presented and shown to provide an acceptable approximation to the results of one-dimensional numerical DDT simulations. Our analysis predicts a ~103 s long UV/optical flash with a luminosity of ~1 to ~3 × 1039 erg s-1. Lower luminosity corresponds to faster (turbulent) deflagration velocity. The luminosity of the UV flash is predicted to be strongly suppressed at t > t drop ~ 1 hr due to the deviation from pure radiation domination.
NASA Technical Reports Server (NTRS)
Buffum, Daniel H.; King, Aaron J.; Capece, Vincent R.; El-Aini, Yehia M.
1996-01-01
The aerodynamics of a cascade of airfoils oscillating in torsion about the midchord is investigated experimentally at a large mean incidence angle and, for reference, at a low mean incidence angle. The airfoil section is representative of a modern, low aspect ratio, fan blade tip section. Time-dependent airfoil surface pressure measurements were made for reduced frequencies up to 0.8 for out-of-phase oscillations at Mach numbers up to 0.8 and chordal incidence angles of 0 deg and 10 deg. For the 10 deg chordal incidence angle, a separation bubble formed at the leading edge of the suction surface. The separated flow field was found to have a dramatic effect on the chordwise distribution of the unsteady pressure. In this region, substantial deviations from the attached flow data were found with the deviations becoming less apparent in the aft region of the airfoil for all reduced frequencies. In particular, near the leading edge the separated flow had a strong destabilizing influence while the attached flow had a strong stabilizing influence.
Oscillating cascade aerodynamics at large mean incidence
NASA Technical Reports Server (NTRS)
Buffum, Daniel H.; King, Aaron J.; El-Aini, Yehia M.; Capece, Vincent R.
1996-01-01
The aerodynamics of a cascade of airfoils oscillating in torsion about the midchord is investigated experimentally at a large mean incidence angle and, for reference, at a low mean incidence angle. The airfoil section is representative of a modern, low aspect ratio, fan blade tip section. Time-dependent airfoil surface pressure measurements were made for reduced frequencies of up to 1.2 for out-of-phase oscillations at a Mach number of 0.5 and chordal incidence angles of 0 deg and 10 deg; the Reynolds number was 0.9 x l0(exp 6). For the 10 deg chordal incidence angle, a separation bubble formed at the leading edge of the suction surface. The separated flow field was found to have a dramatic effect on the chordwise distribution of the unsteady pressure. In this region, substantial deviations from the attached flow data were found with the deviations becoming less apparent in the aft region of the airfoil for all reduced frequencies. In particular, near the leading edge the separated flow had a strong destabilizing influence while the attached flow had a strong stabilizing influence.
Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M
2012-10-09
To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P < 0.001), tests performed after lunch (P < 0.001), and tests performed in the summer or autumn (P < 0.001). The effects of time of day and season appeared to depend on disease stage. Independent of these effects, the percentage of false-positive answers strongly influenced the MD with a 1 dB increase in MD per 10% increase in false-positive answers. Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.
Liquid-vapor rectilinear diameter revisited
NASA Astrophysics Data System (ADS)
Garrabos, Y.; Lecoutre, C.; Marre, S.; Beysens, D.; Hahn, I.
2018-02-01
In the modern theory of critical phenomena, the liquid-vapor density diameter in simple fluids is generally expected to deviate from a rectilinear law approaching the critical point. However, by performing precise scannerlike optical measurements of the position of the SF6 liquid-vapor meniscus, in an approach much closer to criticality in temperature and density than earlier measurements, no deviation from a rectilinear diameter can be detected. The observed meniscus position from far (10 K ) to extremely close (1 mK ) to the critical temperature is analyzed using recent theoretical models to predict the complete scaling consequences of a fluid asymmetry. The temperature dependence of the meniscus position appears consistent with the law of rectilinear diameter. The apparent absence of the critical hook in SF6 therefore seemingly rules out the need for the pressure scaling field contribution in the complete scaling theoretical framework in this SF6 analysis. More generally, this work suggests a way to clarify the experimental ambiguities in the simple fluids for the near-critical singularities in the density diameter.
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.
Determining Equilibrium Position For Acoustical Levitation
NASA Technical Reports Server (NTRS)
Barmatz, M. B.; Aveni, G.; Putterman, S.; Rudnick, J.
1989-01-01
Equilibrium position and orientation of acoustically-levitated weightless object determined by calibration technique on Earth. From calibration data, possible to calculate equilibrium position and orientation in presence of Earth gravitation. Sample not levitated acoustically during calibration. Technique relies on Boltzmann-Ehrenfest adiabatic-invariance principle. One converts resonant-frequency-shift data into data on normalized acoustical potential energy. Minimum of energy occurs at equilibrium point. From gradients of acoustical potential energy, one calculates acoustical restoring force or torque on objects as function of deviation from equilibrium position or orientation.
Rogue waves driven by polarization instabilities in a long ring fiber oscillator
NASA Astrophysics Data System (ADS)
Kolpakov, S. A.; Kbashi, Hani; Sergeyev, Sergey
2017-05-01
We present an experimental and theoretical results of a study of a complex nonlinear polarization dynamics in a passively self-mode-locked erbium-doped fiber oscillator implemented in a ring configuration and operating near lasing threshold. The theoretical model consists of seven coupled non-linear equations and takes into account both orthogonal states of polarizations in the fiber. The experiment confirmed the existence of seven eigenfrequencies, predicted by the model due to polarization instability near lasing threshold. By adjusting the state of polarization of the pump and in-cavity birefringence we changed some eigenfrequencies from being different (non-degenerate state) to matching (degenerate state). The non-degenerate states of oscillator lead to the L-shaped probability distribution function and true rogue wave regime with a positive dominant Lyapunov exponent value between 1.4 and 2.6. Small detuning from partially degenerate case also leads to L-shaped probability distribution function with the tail trespassing eight standard deviations threshold, giving periodic patterns of pulses along with positive dominant Lyapunov exponent of a filtered signal between 0.6 and 3.2. The partial degeneration, in turn, guides to quasi-symmetric distribution and the value of dominant Lyapunov exponent of 42 which is a typical value for systems with a source of the strongly nonhomogeneous external noise.
NASA Astrophysics Data System (ADS)
Ratnasari, D.; Nazir, F.; Toresano, L. O. H. Z.; Pawiro, S. A.; Soejoko, D. S.
2016-03-01
The prevalence of chronic renal diseases in Indonesia has an increasing annual trend, because it is frequently unrecognized and often co-exists with other disease. GFR and ERPF are parameters currently utilized to estimate renal function at routine renal scintigraphy 99m-Tc DTPA study. This study used 99m-Tc DTPA to measure GFR and ERPF. The purpose of this study was to find the correlation between ERPF and GFR, for ERPF analysis with Schlegel's method, and GFR analysis with Gate's method, as well as to find correction factor between both variables. Analysis of renal scintigraphy has been performed at Department of Nuclear Medicine Pertamina Center Hospital to thirty patient images acquired from 2014 to 2015 which were analyzed retrospectively data, using gamma camera dual head with counting method from renal scintigraphy 99m-Tc DTPA study. The calculation was executed by means of both display and manual calculation. Pearson's statistical analysis resulted on Positive Correlation for all data, with ERPF and GFR (display) showing Strongly Positive Correlation (r = 0.82; p- value < 0.05). Standard deviation was found to be 27.58 and 107.64 for GFR and ERPF (display), respectively. Our result indicated that the use of 99mTc-DTPA measure ERPF was not recommended.
Welding deviation detection algorithm based on extremum of molten pool image contour
NASA Astrophysics Data System (ADS)
Zou, Yong; Jiang, Lipei; Li, Yunhua; Xue, Long; Huang, Junfen; Huang, Jiqiang
2016-01-01
The welding deviation detection is the basis of robotic tracking welding, but the on-line real-time measurement of welding deviation is still not well solved by the existing methods. There is plenty of information in the gas metal arc welding(GMAW) molten pool images that is very important for the control of welding seam tracking. The physical meaning for the curvature extremum of molten pool contour is revealed by researching the molten pool images, that is, the deviation information points of welding wire center and the molten tip center are the maxima and the local maxima of the contour curvature, and the horizontal welding deviation is the position difference of these two extremum points. A new method of weld deviation detection is presented, including the process of preprocessing molten pool images, extracting and segmenting the contours, obtaining the contour extremum points, and calculating the welding deviation, etc. Extracting the contours is the premise, segmenting the contour lines is the foundation, and obtaining the contour extremum points is the key. The contour images can be extracted with the method of discrete dyadic wavelet transform, which is divided into two sub contours including welding wire and molten tip separately. The curvature value of each point of the two sub contour lines is calculated based on the approximate curvature formula of multi-points for plane curve, and the two points of the curvature extremum are the characteristics needed for the welding deviation calculation. The results of the tests and analyses show that the maximum error of the obtained on-line welding deviation is 2 pixels(0.16 mm), and the algorithm is stable enough to meet the requirements of the pipeline in real-time control at a speed of less than 500 mm/min. The method can be applied to the on-line automatic welding deviation detection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoegele, W.; Loeschel, R.; Dobler, B.
2011-02-15
Purpose: In this work, a novel stochastic framework for patient positioning based on linac-mounted CB projections is introduced. Based on this formulation, the most probable shifts and rotations of the patient are estimated, incorporating interfractional deformations of patient anatomy and other uncertainties associated with patient setup. Methods: The target position is assumed to be defined by and is stochastically determined from positions of various features such as anatomical landmarks or markers in CB projections, i.e., radiographs acquired with a CB-CT system. The patient positioning problem of finding the target location from CB projections is posed as an inverse problem withmore » prior knowledge and is solved using a Bayesian maximum a posteriori (MAP) approach. The prior knowledge is three-fold and includes the accuracy of an initial patient setup (such as in-room laser and skin marks), the plasticity of the body (relative shifts between target and features), and the feature detection error in CB projections (which may vary depending on specific detection algorithm and feature type). For this purpose, MAP estimators are derived and a procedure of using them in clinical practice is outlined. Furthermore, a rule of thumb is theoretically derived, relating basic parameters of the prior knowledge (initial setup accuracy, plasticity of the body, and number of features) and the parameters of CB data acquisition (number of projections and accuracy of feature detection) to the expected estimation accuracy. Results: MAP estimation can be applied to arbitrary features and detection algorithms. However, to experimentally demonstrate its applicability and to perform the validation of the algorithm, a water-equivalent, deformable phantom with features represented by six 1 mm chrome balls were utilized. These features were detected in the cone beam projections (XVI, Elekta Synergy) by a local threshold method for demonstration purposes only. The accuracy of estimation (strongly varying for different plasticity parameters of the body) agreed with the rule of thumb formula. Moreover, based on this rule of thumb formula, about 20 projections for 6 detectable features seem to be sufficient for a target estimation accuracy of 0.2 cm, even for relatively large feature detection errors with standard deviation of 0.5 cm and spatial displacements of the features with standard deviation of 0.5 cm. Conclusions: The authors have introduced a general MAP-based patient setup algorithm accounting for different sources of uncertainties, which are utilized as the prior knowledge in a transparent way. This new framework can be further utilized for different clinical sites, as well as theoretical developments in the field of patient positioning for radiotherapy.« less
Zeng, Jinle; Chang, Baohua; Du, Dong; Wang, Li; Chang, Shuhe; Peng, Guodong; Wang, Wenzhu
2018-01-05
Multi-layer/multi-pass welding (MLMPW) technology is widely used in the energy industry to join thick components. During automatic welding using robots or other actuators, it is very important to recognize the actual weld pass position using visual methods, which can then be used not only to perform reasonable path planning for actuators, but also to correct any deviations between the welding torch and the weld pass position in real time. However, due to the small geometrical differences between adjacent weld passes, existing weld position recognition technologies such as structured light methods are not suitable for weld position detection in MLMPW. This paper proposes a novel method for weld position detection, which fuses various kinds of information in MLMPW. First, a synchronous acquisition method is developed to obtain various kinds of visual information when directional light and structured light sources are on, respectively. Then, interferences are eliminated by fusing adjacent images. Finally, the information from directional and structured light images is fused to obtain the 3D positions of the weld passes. Experiment results show that each process can be done in 30 ms and the deviation is less than 0.6 mm. The proposed method can be used for automatic path planning and seam tracking in the robotic MLMPW process as well as electron beam freeform fabrication process.
Bifurcation analysis of a discrete-time ratio-dependent predator-prey model with Allee Effect
NASA Astrophysics Data System (ADS)
Cheng, Lifang; Cao, Hongjun
2016-09-01
A discrete-time predator-prey model with Allee effect is investigated in this paper. We consider the strong and the weak Allee effect (the population growth rate is negative and positive at low population density, respectively). From the stability analysis and the bifurcation diagrams, we get that the model with Allee effect (strong or weak) growth function and the model with logistic growth function have somewhat similar bifurcation structures. If the predator growth rate is smaller than its death rate, two species cannot coexist due to having no interior fixed points. When the predator growth rate is greater than its death rate and other parameters are fixed, the model can have two interior fixed points. One is always unstable, and the stability of the other is determined by the integral step size, which decides the species coexistence or not in some extent. If we increase the value of the integral step size, then the bifurcated period doubled orbits or invariant circle orbits may arise. So the numbers of the prey and the predator deviate from one stable state and then circulate along the period orbits or quasi-period orbits. When the integral step size is increased to a critical value, chaotic orbits may appear with many uncertain period-windows, which means that the numbers of prey and predator will be chaotic. In terms of bifurcation diagrams and phase portraits, we know that the complexity degree of the model with strong Allee effect decreases, which is related to the fact that the persistence of species can be determined by the initial species densities.
Accuracy of Digital vs. Conventional Implant Impressions
Lee, Sang J.; Betensky, Rebecca A.; Gianneschi, Grace E.; Gallucci, German O.
2015-01-01
The accuracy of digital impressions greatly influences the clinical viability in implant restorations. The aim of this study is to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis. Thirty gypsum and 30 digitally milled models impressed directly from a reference model were prepared. The models were scanned by a laboratory scanner and 30 STL datasets from each group were imported to an inspection software. The datasets were aligned to the reference dataset by a repeated best fit algorithm and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision. Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model, exhibited statistical significance (p<0.001, p=0.020 respectively). PMID:24720423
Technology research for strapdown inertial experiment and digital flight control and guidance
NASA Technical Reports Server (NTRS)
Carestia, R. A.; Cottrell, D. E.
1985-01-01
A helicopter flight-test program to evaluate the performance of Honeywell's Tetrad - a strapdown, laser gyro, inertial navitation system is discussed. The results of 34 flights showed a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n.mi., with a standard deviation of 1.48 n.m.; and a modeled mean-position-error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. Tetrad's four-ring laser gyros provided reliable and accurate angular rate sensing during the test program and on sensor failures were detected during the evaluation. Criteria suitable for investigating cockpit systems in rotorcraft were developed. This criteria led to the development of two basic simulators. The first was a standard simulator which could be used to obtain baseline information for studying pilot workload and interactions. The second was an advanced simulator which integrated the RODAAS developed by Honeywell into this simulator. The second area also included surveying the aerospace industry to determine the level of use and impact of microcomputers and related components on avionics systems.
Flight test results of the strapdown ring laser gyro tetrad inertial navigation system
NASA Technical Reports Server (NTRS)
Carestia, R. A.; Hruby, R. J.; Bjorkman, W. S.
1983-01-01
A helicopter flight test program undertaken to evaluate the performance of Tetrad (a strap down, laser gyro, inertial navigation system) is described. The results of 34 flights show a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n. mi., with a standard deviation of 1.48 n. mi.; and a modeled mean position error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. No laser gyro or accelerometer failures were detected during the flight tests. Off line parity residual studies used simulated failures with the prerecorded flight test and laboratory test data. The airborne Tetrad system's failure--detection logic, exercised during the tests, successfully demonstrated the detection of simulated ""hard'' failures and the system's ability to continue successfully to navigate by removing the simulated faulted sensor from the computations. Tetrad's four ring laser gyros provided reliable and accurate angular rate sensing during the 4 yr of the test program, and no sensor failures were detected during the evaluation of free inertial navigation performance.
Effects of vibration on occupant driving performance under simulated driving conditions.
Azizan, Amzar; Fard, M; Azari, Michael F; Jazar, Reza
2017-04-01
Although much research has been devoted to the characterization of the effects of whole-body vibration on seated occupants' comfort, drowsiness induced by vibration has received less attention to date. There are also little validated measurement methods available to quantify whole body vibration-induced drowsiness. Here, the effects of vibration on drowsiness were investigated. Twenty male volunteers were recruited for this experiment. Drowsiness was measured in a driving simulator, before and after 30-min exposure to vibration. Gaussian random vibration, with 1-15 Hz frequency bandwidth was used for excitation. During the driving session, volunteers were required to obey the speed limit of 100 kph and maintain a steady position on the left-hand lane. A deviation in lane position, steering angle variability, and speed deviation were recorded and analysed. Alternatively, volunteers rated their subjective drowsiness by Karolinska Sleepiness Scale (KSS) scores every 5-min. Following 30-min of exposure to vibration, a significant increase of lane deviation, steering angle variability, and KSS scores were observed in all volunteers suggesting the adverse effects of vibration on human alertness level. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yang, Yang; Pu, Fang; Lv, Xiaoning; Li, Shuyu; Li, Jing; Li, Deyu; Li, Minggao
2015-01-01
Galvanic vestibular stimulation (GVS) can be used to study the body's response to vestibular stimuli. This study aimed to investigate whether postural responses to GVS were different between pilots and the general populace. Bilateral bipolar GVS was applied with a constant-current profile to 12 pilots and 12 control subjects via two electrodes placed over the mastoid processes. Both GVS threshold and the center of pressure's trajectory (COP's trajectory) were measured. Position variability of COP during spontaneous body sway and peak displacement of COP during GVS-induced body sway were calculated in the medial-lateral direction. Spontaneous body sway was slight for all subjects, and there was no significant difference in the value of COP position variability between the pilots and controls. Both the GVS threshold and magnitude of GVS-induced body deviation were similar for different GVS polarities. GVS thresholds were similar between the two groups, but the magnitude of GVS-induced body deviation in the controls was significantly larger than that in the pilots. The pilots showed less GVS-induced body deviation, meaning that pilots may have a stronger ability to suppress vestibular illusions. PMID:25632395
Moralized Health-Related Persuasion Undermines Social Cohesion
Täuber, Susanne
2018-01-01
Integrating theory and research on persuasion, moralization, and intergroup relations, the present research aims to highlight the far-reaching impact of health-related persuasion on society. I propose that governments’ health-related persuasion leads to the emergence of new social norms, and in particular moral norms. Importantly, moral norms provide strong behavioral imperatives and are seen as binding for group members. This suggests that moralized persuasion has a strong potential to divide society along the lines of citizens who conform to and citizens who deviate from health-related moral norms. Thus, departing from the traditional focus on targets of persuasion, the present research focuses on those holding a moralized view on health and lifestyle. Key aspects of social cohesion as defined by the OECD (2011) have been tested across four studies. The main hypothesis tested is that those conforming to the norm (e.g., non-smokers, normal weight people, people with healthy lifestyles) will stigmatize those deviating from the norm (e.g., smokers, overweight people, people with unhealthy lifestyles). Flowing from stigmatization, less inclusion, lower solidarity with and greater endorsement of unequal treatment of those deviating from the moral norm are predicted. Four survey studies (total N = 1568) examining the proposed associations among non-smokers, normal weight people, and employees with healthy lifestyles are presented. The studies provide unanimous support for the hypothesis, with meta-analysis providing further support for the reliability of the findings. Consistent across studies, social cohesion indicators were negatively affected by health moralization through stigmatization of those deviating from health-related moral norms. Findings highlight an under-acknowledged potential of moralized health-related persuasion to divide society, thereby undermining cohesion and the achievement of important societal goals. In the discussion, limitations and relevant routes for future research are highlighted. Recommendations are derived for policy makers, institutions, employers, and individuals. PMID:29946279
Cathcart, Nicole; Kitaev, Vladimir
2011-09-27
Silver nanoprisms of a predominantly hexagonal shape have been prepared using a ligand combination of a strongly binding thiol, captopril, and charge-stabilizing citrate together with hydrogen peroxide as an oxidative etching agent and a strong base that triggered nanoprism formation. The role of the reagents and their interplay in the nanoprism synthesis is discussed in detail. The beneficial role of chloride ions to attain a high degree of reproducibility and monodispersity of the nanoprisms is elucidated. Control over the nanoprism width, thickness, and, consequently, plasmon resonance in the system has been demonstrated. One of the crucial factors in the nanoprism synthesis was the slow, controlled aggregation of thiolate-stabilized silver nanoclusters as the intermediates. The resulting superior monodispersity (better than ca. 10% standard deviation in lateral size and ca. 15% standard deviation in thickness (<1 nm variation)) and charge stabilization of the produced silver nanoprisms enabled the exploration of the rich diversity of the self-assembled morphologies in the system. Regular columnar assemblies of the self-assembled nanoprisms spanning 2-3 μm in length have been observed. Notably, the helicity of the columnar phases was evident, which can be attributed to the chirality of the strongly binding thiol ligand. Finally, the enhancement of Raman scattering has been observed after oxidative removal of thiolate ligands from the AgNPR surface. © 2011 American Chemical Society
Wingen, Andreas; Schmitz, Oliver; Evans, Todd E.; ...
2014-01-01
The heat flux patterns measured in low-collisionality DIII-D H-mode plasmas strongly deviate from simultaneously measured CII emission patterns, used as indicator of particle flux, during applied resonant magnetic perturbations. While the CII emission clearly shows typical striations, which are similar to magnetic footprint patterns obtained from vacuum field line tracing, the heat flux is usually dominated by one large peak at the strike point position. The vacuum approximation, which only considers applied magnetic fields and neglects plasma response and plasma effects, cannot explain the shape of the observed heat flux pattern. One possible explanation is the effect of particle drifts.more » This is included in the field line equations and the results are discussed with reference to the measurement. Electrons and ions show di fferent drift motions at thermal energy levels in a guiding center approximation. While electrons hardly deviate from the field lines, ions can drift several centimetres away from field line flux surfaces. A model is presented in which an ion heat flux, based on the ion drift motion from various kinetic energies as they contribute to a thermal Maxwellian distribution, is calculated. The simulated heat flux is directly compared to measurements with a varying edge safety factor q95. This analysis provides evidence for the dominate e ect of high-energy ions in carrying heat from the plasma inside the separatrix to the target. High-energy ions are deposited close to the unperturbed strike line while low-energy ions can travel into the striated magnetic topology.« less
Comparison of relationships between four common anthropometric measures and incident diabetes.
Lee, Crystal Man Ying; Woodward, Mark; Pandeya, Nirmala; Adams, Robert; Barrett-Connor, Elizabeth; Boyko, Edward J; Eliasson, Mats; Franco, Laercio J; Fujimoto, Wilfred Y; Gonzalez, Clicerio; Howard, Barbara V; Jacobs, David R; Keinanen-Kiukaanniemi, Sirkka; Magliano, Dianna; Schreiner, Pamela; Shaw, Jonathan E; Stevens, June; Taylor, Anne; Tuomilehto, Jaakko; Wagenknecht, Lynne; Huxley, Rachel R
2017-10-01
First, to conduct a detailed exploration of the prospective relations between four commonly used anthropometric measures with incident diabetes and to examine their consistency across different population subgroups. Second, to compare the ability of each of the measures to predict five-year risk of diabetes. We conducted a meta-analysis of individual participant data on body mass index (BMI), waist circumference (WC), waist-hip and waist-height ratio (WHtR) from the Obesity, Diabetes and Cardiovascular Disease Collaboration. Cox proportional hazard models were used to estimate the association between a one standard deviation increment in each anthropometric measure and incident diabetes. Harrell's concordance statistic was used to test the predictive accuracy of each measure for diabetes risk at five years. Twenty-one studies with 154,998 participants and 9342 cases of incident diabetes were available. Each of the measures had a positive association with incident diabetes. A one standard deviation increment in each of the measures was associated with 64-80% higher diabetes risk. WC and WHtR more strongly associated with risk than BMI (ratio of hazard ratios: 0.95 [0.92,0.99] - 0.97 [0.95,0.98]) but there was no appreciable difference between the four measures in the predictive accuracy for diabetes at five years. Despite suggestions that abdominal measures of obesity have stronger associations with incident diabetes and better predictive accuracy than BMI, we found no overall advantage in any one measure at discriminating the risk of developing diabetes. Any of these measures would suffice to assist in primary diabetes prevention efforts. Copyright © 2017 Elsevier B.V. All rights reserved.
Nasal airway and septal variation in unilateral and bilateral cleft lip and palate.
Starbuck, John M; Friel, Michael T; Ghoneima, Ahmed; Flores, Roberto L; Tholpady, Sunil; Kula, Katherine
2014-10-01
Cleft lip and palate (CLP) affects the dentoalveolar and nasolabial facial regions. Internal and external nasal dysmorphology may persist in individuals born with CLP despite surgical interventions. 7-18 year old individuals born with unilateral and bilateral CLP (n = 50) were retrospectively assessed using cone beam computed tomography. Anterior, middle, and posterior nasal airway volumes were measured on each facial side. Septal deviation was measured at the anterior and posterior nasal spine, and the midpoint between these two locations. Data were evaluated using principal components analysis (PCA), multivariate analysis of variance (MANOVA), and post-hoc ANOVA tests. PCA results show partial separation in high dimensional space along PC1 (48.5% variance) based on age groups and partial separation along PC2 (29.8% variance) based on CLP type and septal deviation patterns. MANOVA results indicate that age (P = 0.007) and CLP type (P ≤ 0.001) significantly affect nasal airway volume and septal deviation. ANOVA results indicate that anterior nasal volume is significantly affected by age (P ≤ 0.001), whereas septal deviation patterns are significantly affected by CLP type (P ≤ 0.001). Age and CLP type affect nasal airway volume and septal deviation patterns. Nasal airway volumes tend to be reduced on the clefted sides of the face relative to non-clefted sides of the face. Nasal airway volumes tend to strongly increase with age, whereas septal deviation values tend to increase only slightly with age. These results suggest that functional nasal breathing may be impaired in individuals born with the unilateral and bilateral CLP deformity. © 2014 Wiley Periodicals, Inc.
Santric-Milicevic, M; Vasic, V; Terzic-Supic, Z
2016-08-15
In times of austerity, the availability of econometric health knowledge assists policy-makers in understanding and balancing health expenditure with health care plans within fiscal constraints. The objective of this study is to explore whether the health workforce supply of the public health care sector, population number, and utilization of inpatient care significantly contribute to total health expenditure. The dependent variable is the total health expenditure (THE) in Serbia from the years 2003 to 2011. The independent variables are the number of health workers employed in the public health care sector, population number, and inpatient care discharges per 100 population. The statistical analyses include the quadratic interpolation method, natural logarithm and differentiation, and multiple linear regression analyses. The level of significance is set at P < 0.05. The regression model captures 90 % of all variations of observed dependent variables (adjusted R square), and the model is significant (P < 0.001). Total health expenditure increased by 1.21 standard deviations, with an increase in health workforce growth rate by 1 standard deviation. Furthermore, this rate decreased by 1.12 standard deviations, with an increase in (negative) population growth rate by 1 standard deviation. Finally, the growth rate increased by 0.38 standard deviation, with an increase of the growth rate of inpatient care discharges per 100 population by 1 standard deviation (P < 0.001). Study results demonstrate that the government has been making an effort to control strongly health budget growth. Exploring causality relationships between health expenditure and health workforce is important for countries that are trying to consolidate their public health finances and achieve universal health coverage at the same time.
Schellman, J A
1990-08-31
The properties of a simple model for solvation in mixed solvents are explored in this paper. The model is based on the supposition that solvent replacement is a simple one-for-one substitution reaction at macromolecular sites which are independent of one another. This leads to a new form for the binding polynomial in which all terms are associated with ligand interchange rather than ligand addition. The principal solvent acts as one of the ligands. Thermodynamic analysis then shows that thermodynamic binding (i.e., selective interaction) depends on the properties of K'-1, whereas stoichiometric binding (site occupation) depends on K'. K' is a 'practical' interchange equilibrium constant given by (f3/f1)K, where K is the true equilibrium constant for the interchange of components 3 and 1 on the site and f3 and f4 denote their respective activity coefficients on the mole fraction scale. Values of K' less than unity lead to negative selective interaction. It is selective interaction and not occupation number which determines the thermodynamic effects of solvation. When K' greater than 100 on the mole fraction scale or K' greater than 2 on the molality scale (in water), the differences between stoichiometric binding and selective interaction become less than 1%. The theory of this paper is therefore necessary only for very weak binding constants. When K'-1 is small, large concentrations of the added solvent component are required to produce a thermodynamic effect. Under these circumstances the isotherms for the selective interaction and for the excess (or transfer) free energy are strongly dependent on the behavior of the activity coefficients of both solvent components. Two classes of behavior are described depending on whether the components display positive or negative deviations from Raoult's law. Examples which are discussed are aqueous solutions of urea and guanidinium chloride for positive deviations and of sucrose and glucose for negative deviations. Examination of the few studies which have been reported in the literature shows that most of the qualitative features of the stabilization of proteins by sugars and their destabilization by urea and guanidinium chloride are faithfully represented with the model. This includes maxima in the free energy of stabilization and destabilization, decreased and zero selective interaction at high concentrations, etc. These phenomena had no prior explanation. Deficiencies in the model as a representation of solvation in aqueous solution are discussed in the appendix.
Haji-Momenian, S; Parkinson, W; Khati, N; Brindle, K; Earls, J; Zeman, R K
2018-06-01
To determine the sensitivity, specificity, and predictive values of single-energy non-contrast hepatic steatosis criteria on dual-energy virtual non-contrast (VNC) images. Forty-eight computed tomography (CT) examinations, which included single-energy non-contrast (TNC) and contrast-enhanced dual-energy CT angiography (CTA) of the abdomen, were enrolled. VNC images were reconstructed from the CTA. Region of interest (ROI) attenuations were measured in the right and left hepatic lobes, spleen, and aorta on TNC and VNC images. The right and left hepatic lobes were treated as separate samples. Steatosis was diagnosed based on TNC liver attenuation of ≤40 HU or liver attenuation index (LAI) of ≤-10 HU, which are extremely specific and predictive for moderate to severe steatosis. The sensitivity, specificity, and predictive values of VNC images for steatosis were calculated. VNC-TNC deviations were correlated with aortic enhancement and patient water equivalent diameter (PWED). Thirty-two liver ROIs met steatosis criteria based on TNC attenuation; VNC attenuation had sensitivity, specificity, and a positive predictive value of 66.7%, 100%, and 100%, respectively. Twenty-one liver ROIs met steatosis criteria based on TNC LAI. VNC LAI had sensitivity, specificity, and positive predictive values of 61.9%, 90.7%, and 65%, respectively. Hepatic and splenic VNC-TNC deviations did not correlate with one another (R 2 =0.08), aortic enhancement (R 2 <0.06) or PWED (R 2 <0.09). Non-contrast hepatic attenuation criteria is extremely specific and positively predictive for moderate to severe steatosis on VNC reconstructions from the arterial phase. Hepatic attenuation performs better than LAI criteria. VNC deviations are independent of aortic enhancement and PWED. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
van de Loo, Aurora J A E; Bervoets, Adriana C; Mooren, Loes; Bouwmeester, Noor H; Garssen, Johan; Zuiker, Rob; van Amerongen, Guido; van Gerven, Joop; Singh, Jaskaran; der Ark, Peter Van; Fedgchin, Maggie; Morrison, Randall; Wajs, Ewa; Verster, Joris C
2017-11-01
The purpose of this study is to evaluate the single dose effect of intranasal esketamine (84 mg) compared to placebo on on-road driving performance. Mirtazapine (oral, 30 mg) was used as a positive control, as this antidepressant drug is known to negatively affect driving performance. Twenty-six healthy volunteers aged 21 to 60 years were enrolled in this study. In the evening, 8 h after treatment administration, participants conducted the standardized 100-km on-road driving test. Primary outcome measure was the standard deviation of lateral position (SDLP), i.e., the weaving of the car. Mean lateral position, mean speed, and standard deviation of speed were secondary outcome measures. For SDLP, non-inferiority analyses were conducted, using +2.4 cm (relative to placebo) as a predefined non-inferiority margin for clinical relevant impairment. Twenty-four participants completed the study. No significant SDLP difference was found between esketamine and placebo (p = 0.7638), whereas the SDLP after mirtazapine was significantly higher when compared to placebo (p = 0.0001). The upper limit of the two-sided 95% confidence interval (CI) of the mean difference between esketamine and placebo was +0.86 cm, i.e., <+2.4 cm, thus demonstrating that esketamine was non-inferior to placebo. Non-inferiority could not be concluded for mirtazapine (+3.15 cm SDLP relative to placebo). No significant differences in mean speed, standard deviation of speed, and mean lateral position were observed between the active treatments and placebo. No significant difference in driving performance was observed 8 h after administering intranasal esketamine (84 mg) or placebo. In contrast, oral mirtazapine (30 mg) significantly impaired on road driving performance.
Weinsaft, Jonathan W; Manoushagian, Shant J; Patel, Taral; Shakoor, Aqsa; Kim, Robert J; Mirchandani, Sunil; Lin, Fay; Wong, Franklin J; Szulc, Massimiliano; Okin, Peter M; Kligfield, Paul D; Min, James K
2009-01-01
To assess the utility of stress electrocardiography (ECG) for identifying the presence and severity of obstructive coronary artery disease (CAD) defined by coronary computed tomographic angiography (CCTA) among patients with normal nuclear myocardial perfusion imaging (MPI). The study population comprised 119 consecutive patients with normal MPI who also underwent CCTA (interval 3.5+/-3.8 months). Stress ECG was performed at the time of MPI. CCTA and MPI were interpreted using established scoring systems, and CCTA was used to define the presence and extent of CAD, which was quantified by a coronary artery jeopardy score. Within this population, 28 patients (24%) had obstructive CAD identified by CCTA. The most common CAD pattern was single-vessel CAD (61%), although proximal vessel involvement was present in 46% of patients. Patients with CAD were nearly three times more likely to have positive standard test responses (1 mm ST-segment deviation) than patients with patent coronary arteries (36 vs. 13%, P=0.007). In multivariate analysis, a positive ST-segment test response was an independent marker for CAD (odds ratio: 2.02, confidence interval: 1.09-3.78, P=0.03) even after adjustment for a composite of clinical cardiac risk factors (odds ratio: 1.85, confidence interval: 1.05-3.23, P=0.03). Despite uniformly normal MPI, mean coronary jeopardy score was three-fold higher among patients with positive compared to those with negative ST-segment response to exercise or dobutamine stress (1.9+/-2.7 vs. 0.5+/-1.4, P=0.03). Stress-induced ST-segment deviation is an independent marker for obstructive CAD among patients with normal MPI. A positive stress ECG identifies patients with a greater anatomic extent of CAD as quantified by coronary jeopardy score.
[Quantification of prostate movements during radiotherapy].
Artignan, X; Rastkhah, M; Balosso, J; Fourneret, P; Gilliot, O; Bolla, M
2006-11-01
Decrease treatment uncertainties is one of the most important challenge in radiation oncology. Numerous techniques are available to quantify prostate motion and visualise prostate location day after day before each irradiation: CT-scan, cone-beam-CT-Scan, ultrason, prostatic markers... The knowledge of prostate motion is necessary to define the minimal margin around the target volume needed to avoid mispositioning during treatment session. Different kind of prostate movement have been studied and are reported in the present work: namely, those having a large amplitude extending through out the whole treatment period on one hand; and those with a shorter amplitude happening during treatment session one the other hand. The long lasting movement are mostly anterior-posterior (3 mm standard deviation), secondary in cranial-caudal (1-2 mm standard deviation) and lateral directions (0.5-1 mm standard deviation). They are mostly due to the rectal state of filling and mildly due to bladder filling or inferior limbs position. On the other hand, the shorter movement that occurs during the treatment session is mostly variation of position around a steady point represented by the apex. Ones again, the rectal filling state is the principle cause. This way, during the 20 minutes of a treatment session, including the positioning of the patient, a movement of less than 3 mm could be expected when the rectum is empty. Ideally, real time imaging tools should allow an accurate localisation of the prostate and the adaptation of the dosimetry before each treatment session in a time envelope not exceeding 20 minutes.
[Prism correction in heterophoria].
Kommerell, G; Kromeier, M
2002-01-01
Unlike heterotropia (= manifest strabismus), heterophoria (= latent strabismus) is not a primarily existing condition but is a reaction to an interruption of the sensory-motor feedback control system. The reaction consists of a deviation from the orthovergence position. Binocular vision causes a continuous calibration of the vergence position. This "orthophorisation" explains that in most persons, heterophoria differs only slightly from zero. Nevertheless, a small heterophoria is common (70-80% of the population). The need to compensate for heterophoria by sensory-motor fusion can cause asthenopic complaints, such as headaches with prolonged reading. Since a variety of other defects can lead to similar symptoms, a causal relationship with heterophoria can be assumed only after a thorough differential diagnosis. Prism spectacles or eye muscle surgery for heterophoria should be recommended only after prism trials in free space, which include yoked prisms as a placebo control. Heterophoria should be distinguished from "Winkelfehlsichtigkeit", which is a deviation from orthoposition that results from the "measuring and correcting methodology after H.-J. Haase" (MKH) and is based on the idea that fixation disparity, a minute deviation from orthovergence position, indicates an inability to overcome a larger "vergence angle at rest". Objective recordings have, however, revealed that the subjective tests with stereo cues applied in the MKH can mislead to the assumption of a fixation disparity although both eyes are aligned exactly to the fixation point. A trial conducted in the Netherlands concerning the therapy of asthenopic complaints showed no statistically significant advantage of prism spectacles determined with the MKH over conventional spectacles.
1981-09-15
Deviation Standard deviation of detrended phase component is calculated as 2 - 1/2 in radians, as measured at the receiver output, and not corrected for...next section, were calculated they were corrected for the finite receiver reference frequency of;. f-2 402 MI~z in the following manner. Assuming a...for quiet and disturbed times. The position of the geometrica ,’. enhancement for individual cases is between 60-61°A rather than betwee.o 63-640 A as
Thermodynamic properties and atomic structure of Ca-based liquid alloys
NASA Astrophysics Data System (ADS)
Poizeau, Sophie
To identify the most promising positive electrodes for Ca-based liquid metal batteries, the thermodynamic properties of diverse Ca-based liquid alloys were investigated. The thermodynamic properties of Ca-Sb alloys were determined by emf measurements. It was found that Sb as positive electrode would provide the highest voltage for Ca-based liquid metal batteries (1 V). The price of such a battery would be competitive for the grid-scale energy storage market. The impact of Pb, a natural impurity of Sb, was predicted successfully and confirmed via electrochemical measurements. It was shown that the impact on the open circuit voltage would be minor. Indeed, the interaction between Ca and Sb was demonstrated to be much stronger than between Ca and Pb using thermodynamic modeling, which explains why the partial thermodynamic properties of Ca would not vary much with the addition of Pb to Sb. However, the usage of the positive electrode would be reduced, which would limit the interest of a Pb-Sb positive electrode. Throughout this work, the molecular interaction volume model (MIVM) was used for the first time for alloys with thermodynamic properties showing strong negative deviation from ideality. This model showed that systems such as Ca-Sb have strong short-range order: Ca is most stable when its first nearest neighbors are Sb. This is consistent with what the more traditional thermodynamic model, the regular association model, would predict. The advantages of the MIVM are the absence of assumption regarding the composition of an associate, and the reduced number of fitting parameters (2 instead of 5). Based on the parameters derived from the thermodynamic modeling using the MIVM, a new potential of mixing for liquid alloys was defined to compare the strength of interaction in different Ca-based alloys. Comparing this trend with the strength of interaction in the solid state of these systems (assessed by the energy of formation of the intermetallics), the systems with the most stable intermetallics were found to have the strongest interaction in the liquid state. Eventually, a new criteria was formulated to select electrode materials for liquid metal batteries. Systems with the most stable intermetallics, which can be evaluated by the enthalpy of formation of these systems, will yield the highest voltage when assembled as positive and negative electrodes in a liquid metal battery. (Copies available exclusively from MIT Libraries, libraries.mit.edu/docs - docs@mit.edu)
Nuttin, Bart; Gielen, Frans; van Kuyck, Kris; Wu, Hemmings; Luyten, Laura; Welkenhuysen, Marleen; Brionne, Thomas C; Gabriëls, Loes
2013-01-01
In preparation for a multicenter study, a protocol was written on how to perform surgical targeting of the bed nucleus of the stria terminalis, based on the lead implantation experience in patients with treatment-refractory obsessive-compulsive disorder (OCD) at the Universitaire Ziekenhuizen Leuven (UZ Leuven). When analyzing the postoperative images, we were struck by the fact that the difference between the postoperative position of the leads and the planned position seemed larger than expected. The precision of targeting in four patients with severe OCD who received bilateral model 3391 leads (Medtronic) was compared with the precision of targeting in the last seven patients who underwent surgery at UZ Leuven for movement disorders (four with Parkinson disease and three with essential tremor; all received bilateral leads). Because the leads implanted in six of the seven patients with movement disorders were model 3387 leads (Medtronic), targeting precision was also analyzed in four patients with OCD in whom model 3387 leads were implanted in the same target as the other patients with OCD. In the patients with OCD, every implanted lead deviated at least 1.3 mm from its intended position in at least one of three directions (lateral, anteroposterior, and depth), whereas in the patients with movement disorders, the maximal deviation of any of all implanted leads was 1.3 mm. The deviations in lead placement were comparable in patients with OCD who received a model 3387 implant and patients who received a model 3391 implant. In the patients with OCD, all leads were implanted more posteriorly than planned. The cause of the posterior deviation could not be determined with certainty. The most likely cause was an increased mechanical resistance of the brain tissue along the trajectory when following the targeting protocol compared with the trajectories classically used for subthalamic nucleus or ventral intermediate nucleus of the thalamus stimulation. Copyright © 2013 Elsevier Inc. All rights reserved.
SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Q; Vigneri, P; Madu, C
2016-06-15
Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verificationmore » was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.« less
Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918
Warren, John Robert
2017-01-01
Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749
Holmstrom, Eero; Haberl, Bianca; Pakarinen, Olli H.; ...
2016-02-20
Variability in the short-to-intermediate range order of pure amorphous silicon prepared by different experimental and computational techniques is probed by measuring mass density, atomic coordination, bond-angle deviation, and dihedral angle deviation. It is found that there is significant variability in order parameters at these length scales in this archetypal covalently bonded, monoatomic system. This diversity strongly reflects preparation technique and thermal history in both experimental and simulated systems. Experiment and simulation do not fully quantitatively agree, partly due to differences in the way parameters are accessed. However, qualitative agreement in the trends is identified. Relaxed forms of amorphous silicon closelymore » resemble continuous random networks generated by a hybrid method of bond-switching Monte Carlo and molecular dynamics simulation. As-prepared ion implanted amorphous silicon can be adequately modeled using a structure generated from amorphization via ion bombardement using energetic recoils. Preparation methods which narrowly avoid crystallization such as experimental pressure-induced amorphization or simulated melt-quenching result in inhomogeneous structures that contain regions with significant variations in atomic ordering. Ad hoc simulated structures containing small (1 nm) diamond cubic crystal inclusions were found to possess relatively high bond-angle deviations and low dihedral angle deviations, a trend that could not be reconciled with any experimental material.« less
The impact of physical and mental tasks on pilot mental workoad
NASA Technical Reports Server (NTRS)
Berg, S. L.; Sheridan, T. B.
1986-01-01
Seven instrument-rated pilots with a wide range of backgrounds and experience levels flew four different scenarios on a fixed-base simulator. The Baseline scenario was the simplest of the four and had few mental and physical tasks. An activity scenario had many physical but few mental tasks. The Planning scenario had few physical and many mental taks. A Combined scenario had high mental and physical task loads. The magnitude of each pilot's altitude and airspeed deviations was measured, subjective workload ratings were recorded, and the degree of pilot compliance with assigned memory/planning tasks was noted. Mental and physical performance was a strong function of the manual activity level, but not influenced by the mental task load. High manual task loads resulted in a large percentage of mental errors even under low mental task loads. Although all the pilots gave similar subjective ratings when the manual task load was high, subjective ratings showed greater individual differences with high mental task loads. Altitude or airspeed deviations and subjective ratings were most correlated when the total task load was very high. Although airspeed deviations, altitude deviations, and subjective workload ratings were similar for both low experience and high experience pilots, at very high total task loads, mental performance was much lower for the low experience pilots.
ERIC Educational Resources Information Center
SMITH, STUART E.; AND OTHERS
FACTOR ANALYSIS WAS CARRIED OUT TO ASCERTAIN THE BEST OCCUPATIONAL GROUP LOCATION FOR EACH OF FOUR STRONG VOCATIONAL INTEREST BLANK (SVIB) SCALES--VETERMINARIAN, SENIOR CPA, PHARMACIST, AND MORTICIAN. THE SVIB WAS ADMINISTERED TO 125 MALE LIBERAL ARTS FRESHMEN. MEANS, STANDARD DEVIATIONS, AND INTERCORRELATIONS WERE COMPUTED. THIS FACTOR ANALYSIS…
Initiation and structures of gaseous detonation
NASA Astrophysics Data System (ADS)
Vasil'ev, A. A.; Vasiliev, V. A.
2018-03-01
The analysis of the initiation of a detonation wave (DW) and the emergence of a multi-front structure of the DW-front are presented. It is shown that the structure of the DW arises spontaneously at the stage of a strong overdriven of the wave. The hypothesis of the gradual enhancement of small perturbations on an initially smooth initiating blast wave, traditionally used in the numerical simulation of multi-front detonation, does not agree with the experimental data. The instability of the DW is due to the chemical energy release of the combustible mixture Q. A technique for determining the Q-value of mixture was proposed, based on reconstruction of the trajectory of the expanding wave from the position of the strong explosion model. The wave trajectory at the critical initiation of a multifront detonation in a combustible mixture is compared with the trajectory of an explosive wave from the same initiator in an inert mixture whose gas-dynamic parameters are equivalent to the parameters of the combustible mixture. The energy release of a mixture is defined as the difference in the joint energy release of the initiator and the fuel mixture during the critical initiation and energy release of the initiator when the blast wave is excited in an inert mixture. Observable deviations of the experimental profile of Q from existing model representations were found.
Multiphoton amplitude in a constant background field
NASA Astrophysics Data System (ADS)
Ahmad, Aftab; Ahmadiniaz, Naser; Corradini, Olindo; Kim, Sang Pyo; Schubert, Christian
2018-01-01
In this contribution, we present our recent compact master formulas for the multiphoton amplitudes of a scalar propagator in a constant background field using the worldline fomulation of quantum field theory. The constant field has been included nonperturbatively, which is crucial for strong external fields. A possible application is the scattering of photons by electrons in a strong magnetic field, a process that has been a subject of great interest since the discovery of astrophysical objects like radio pulsars, which provide evidence that magnetic fields of the order of 1012G are present in nature. The presence of a strong external field leads to a strong deviation from the classical scattering amplitudes. We explicitly work out the Compton scattering amplitude in a magnetic field, which is a process of potential relevance for astrophysics. Our final result is compact and suitable for numerical integration.
NASA Astrophysics Data System (ADS)
Nooshiri, N.; Saul, J.; Heimann, S.; Tilmann, F. J.; Dahm, T.
2015-12-01
The use of a 1D velocity model for seismic event location is often associated with significant travel-time residuals. Particularly for regional stations in subduction zones, where the velocity structure strongly deviates from the assumed 1D model, residuals of up to ±10 seconds are observed even for clear arrivals, which leads to strongly biased locations. In fact, due to mostly regional travel-time anomalies, arrival times at regional stations do not match the location obtained with teleseismic picks, and vice versa. If the earthquake is weak and only recorded regionally, or if fast locations based on regional stations are needed, the location may be far off the corresponding teleseismic location. In this case, implementation of travel-time corrections may leads to a reduction of the travel-time residuals at regional stations and, in consequence, significantly improve the relative location accuracy. Here, we have extended the source-specific station terms (SSST) technique to regional and teleseismic distances and adopted the algorithm for probabilistic, non-linear, global-search earthquake location. The method has been applied to specific test regions using P and pP phases from the GEOFON bulletin data for all available station networks. By using this method, a set of timing corrections has been calculated for each station varying as a function of source position. In this way, an attempt is made to correct for the systematic errors, introduced by limitations and inaccuracies in the assumed velocity structure, without solving for a new earth model itself. In this presentation, we draw on examples of the application of this global SSST technique to relocate earthquakes from the Tonga-Fiji subduction zone and from the Chilean margin. Our results have been showing a considerable decrease of the root-mean-square (RMS) residual in earthquake location final catalogs, a major reduction of the median absolute deviation (MAD) of the travel-time residuals at regional stations and sharper images of the seismicity compared to the initial locations.
Fearsome Flashes: A Study Of The Evolution Of Flaring Rates In Cool Stars Using Kepler Cluster Data
NASA Astrophysics Data System (ADS)
Saar, Steven
Strong solar flares can damage power grids, satellites, interrupt communications and GPS information, and threaten astronauts and high latitude air travelers. Despite the potential cost, their frequency is poorly determined. Beyond purely current terrestrial concerns, how the rate of large flares (and associated coronal mass ejections [CMEs], high-energy particle fluxes and far UV emission) varies over the stellar lifetime holds considerable astrophysical interest. These include: the contributions of flares to coronal energy budgets; the importance of flares and CMEs to terrestrial and exoplanet atmospheric and biological evolution; and importance of CME mass loss for angular momentum evolution. We will explore the rate of strong flares and its variation with stellar age, mass and rotation by studying Kepler data of cool stars in two open clusters NGC 6811 (age ~ 1 Gyr) and NGC 6819 (~2.5 Gyr). We will use two flare analysis methods to build white-light flare distributions for cluster stars. One subtracts a low-pass filtered version of the data and analyzes the residue for positive flux deviations, the other does a statistical analysis of the flux deviations vs. time lags compared with a model. For near- solar stars, a known solar relation can then be used to estimate X-ray production by the white-light flares. For stars much hotter or cooler or with significantly different chromospheric density, we will use particle code flare models including bombardment effects to estimate how the X-ray to white light scaling changes. With the X-ray values, we can estimate far UV fluxes and CME rates, building a picture of the flare effects; with the two cluster ages, we can make a first estimate of the solar rate (by projecting to the Sun's age) and begin to build up an understanding of flare rate evolution with mass and age. Our proposal falls squarely in the "Stellar Astrophysics and Exoplanets" research area, and is relevant to NASA astrophysics goals in promoting better understanding the evolution of stars and their exoplanets, and better understanding the environment in which life evolved, and threats to it, both on Earth and in the wider cosmos.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-10
...: The Loop Parkway Bridge, mile 0.7, across Long Creek has a vertical clearance in the closed position... deviation the Loop Parkway Bridge and the Meadowbrook Parkway Bridge may remain in the closed position... operation of the Loop Parkway Bridge, mile 0.7, across Long Creek, and the Meadowbrook Parkway Bridge, mile...
NASA Astrophysics Data System (ADS)
Korte, Andrew R.; Lee, Young Jin
2013-06-01
We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393-9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.
Improved particle position accuracy from off-axis holograms using a Chebyshev model.
Öhman, Johan; Sjödahl, Mikael
2018-01-01
Side scattered light from micrometer-sized particles is recorded using an off-axis digital holographic setup. From holograms, a volume is reconstructed with information about both intensity and phase. Finding particle positions is non-trivial, since poor axial resolution elongates particles in the reconstruction. To overcome this problem, the reconstructed wavefront around a particle is used to find the axial position. The method is based on the change in the sign of the curvature around the true particle position plane. The wavefront curvature is directly linked to the phase response in the reconstruction. In this paper we propose a new method of estimating the curvature based on a parametric model. The model is based on Chebyshev polynomials and is fit to the phase anomaly and compared to a plane wave in the reconstructed volume. From the model coefficients, it is possible to find particle locations. Simulated results show increased performance in the presence of noise, compared to the use of finite difference methods. The standard deviation is decreased from 3-39 μm to 6-10 μm for varying noise levels. Experimental results show a corresponding improvement where the standard deviation is decreased from 18 μm to 13 μm.
Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling
2016-01-01
To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.
Detecting DNA regulatory motifs by incorporating positional trendsin information content
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kechris, Katherina J.; van Zwet, Erik; Bickel, Peter J.
2004-05-04
On the basis of the observation that conserved positions in transcription factor binding sites are often clustered together, we propose a simple extension to the model-based motif discovery methods. We assign position-specific prior distributions to the frequency parameters of the model, penalizing deviations from a specified conservation profile. Examples with both simulated and real data show that this extension helps discover motifs as the data become noisier or when there is a competing false motif.
Tuerk, Andreas; Wiktorin, Gregor; Güler, Serhat
2017-05-01
Accuracy of transcript quantification with RNA-Seq is negatively affected by positional fragment bias. This article introduces Mix2 (rd. "mixquare"), a transcript quantification method which uses a mixture of probability distributions to model and thereby neutralize the effects of positional fragment bias. The parameters of Mix2 are trained by Expectation Maximization resulting in simultaneous transcript abundance and bias estimates. We compare Mix2 to Cufflinks, RSEM, eXpress and PennSeq; state-of-the-art quantification methods implementing some form of bias correction. On four synthetic biases we show that the accuracy of Mix2 overall exceeds the accuracy of the other methods and that its bias estimates converge to the correct solution. We further evaluate Mix2 on real RNA-Seq data from the Microarray and Sequencing Quality Control (MAQC, SEQC) Consortia. On MAQC data, Mix2 achieves improved correlation to qPCR measurements with a relative increase in R2 between 4% and 50%. Mix2 also yields repeatable concentration estimates across technical replicates with a relative increase in R2 between 8% and 47% and reduced standard deviation across the full concentration range. We further observe more accurate detection of differential expression with a relative increase in true positives between 74% and 378% for 5% false positives. In addition, Mix2 reveals 5 dominant biases in MAQC data deviating from the common assumption of a uniform fragment distribution. On SEQC data, Mix2 yields higher consistency between measured and predicted concentration ratios. A relative error of 20% or less is obtained for 51% of transcripts by Mix2, 40% of transcripts by Cufflinks and RSEM and 30% by eXpress. Titration order consistency is correct for 47% of transcripts for Mix2, 41% for Cufflinks and RSEM and 34% for eXpress. We, further, observe improved repeatability across laboratory sites with a relative increase in R2 between 8% and 44% and reduced standard deviation.
Strongly disordered TiN and NbTiN s-wave superconductors probed by microwave electrodynamics.
Driessen, E F C; Coumou, P C J J; Tromp, R R; de Visser, P J; Klapwijk, T M
2012-09-07
We probe the effects of strong disorder (2.4
Lane Level Localization; Using Images and HD Maps to Mitigate the Lateral Error
NASA Astrophysics Data System (ADS)
Hosseinyalamdary, S.; Peter, M.
2017-05-01
In urban canyon where the GNSS signals are blocked by buildings, the accuracy of measured position significantly deteriorates. GIS databases have been frequently utilized to improve the accuracy of measured position using map matching approaches. In map matching, the measured position is projected to the road links (centerlines) in this approach and the lateral error of measured position is reduced. By the advancement in data acquision approaches, high definition maps which contain extra information, such as road lanes are generated. These road lanes can be utilized to mitigate the positional error and improve the accuracy in position. In this paper, the image content of a camera mounted on the platform is utilized to detect the road boundaries in the image. We apply color masks to detect the road marks, apply the Hough transform to fit lines to the left and right road boundaries, find the corresponding road segment in GIS database, estimate the homography transformation between the global and image coordinates of the road boundaries, and estimate the camera pose with respect to the global coordinate system. The proposed approach is evaluated on a benchmark. The position is measured by a smartphone's GPS receiver, images are taken from smartphone's camera and the ground truth is provided by using Real-Time Kinematic (RTK) technique. Results show the proposed approach significantly improves the accuracy of measured GPS position. The error in measured GPS position with average and standard deviation of 11.323 and 11.418 meters is reduced to the error in estimated postion with average and standard deviation of 6.725 and 5.899 meters.
Intraoperative positioning of the hindfoot with the hindfoot alignment guide: a pilot study.
Frigg, Arno; Jud, Lukas; Valderrabano, Victor
2014-01-01
In a previous study, intraoperative positioning of the hindfoot by visual means resulted in the wrong varus/valgus position by 8 degrees and a relatively large standard deviation of 8 degrees. Thus, new intraoperative means are needed to improve the precision of hindfoot surgery. We therefore sought a hindfoot alignment guide that would be as simple as the alignment guides used in total knee arthroplasty. A novel hindfoot alignment guide (HA guide) has been developed that projects the mechanical axis from the tibia down to the heel. The HA guide enables the positioning of the hindfoot in the desired varus/valgus position and in plantigrade position in the lateral plane. The HA guide was used intraoperatively from May through November 2011 in 11 complex patients with simultaneous correction of the supramalleolar, tibiotalar, and inframalleolar alignment. Pre- and postoperative Saltzman views were taken and the position was measured. The HA guide significantly improved the intraoperative positioning compared with visual means: The accuracy with the HA guide was 4.5 ± 5.1 degrees (mean ± standard deviation) and without the HA guide 9.4 ± 5.5 degrees (P < .05). In 7 of 11 patients, the preoperative plan was changed because of the HA guide (2 avoided osteotomies, 5 additional osteotomies). The HA guide helped to position the hindfoot intraoperatively with greater precision than visual means. The HA guide was especially useful for multilevel corrections in which the need for and the amount of a simultaneous osteotomy had to be evaluated intraoperatively. Level IV, case series.
Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan
2016-12-01
The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
SU-E-J-194: Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, E; Rioux, A; Benedict, S
2015-06-15
Purpose: Continuous monitoring of the SBRT lung patient motion during delivery is critical for ensuring adequate target volume margins in stereotactic body radiotherapy (SBRT). This work assesses the deviation of the patient surface motion using a real-time surface tracking system throughout treatment delivery. Methods: Our SBRT protocol employs abdominal compression to reduce the diaphragm movement to within 1 cm, and this is confirmed daily with fluoroscopy. Most patients are prescribed 3–5 fractions, and on treatment day a repeat motion analysis with fluoroscopy is performed, followed by a kV CBCT is aligned with the original planning CT image for 3D setupmore » confirmation. During this entire process a patient surface data restricted to whole chest or the sternum at the middle of the breathing cycle was captured using AlignRT optical surface tracking system and defined as a reference surface. For 10 patients, the deviation of the patient position from the reference surface was recorded during the SBRT delivery in the anterior-posterior (AP) direction at 3–6 measurements per second. Results: On average, the patient position deviated from the reference surface more than 4 mm, 3 mm and 2 mm in the AP direction for 0.95%, 3.7% and 11.1% of the total treatment time, respectively. Only one of the 10 patients showed that the maximum deviation of the patient surface during the SBRT delivery was greater than 1 cm. The average deviation of the patient surface from the reference surface during the SBRT delivery was not greater than 1.6 mm for any patient. Conclusion: This investigation indicates that AP motion can be significant even though the frequency is low. Continuous monitoring during SBRT has demonstrated value in monitoring patient motion ensuring that margins selected for SBRT are appropriate, and the use of non-ionizing and high-frequency imaging can provide useful indicators of motion during treatment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giri, U; Ganesh, T; Saini, V
2016-06-15
Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeatedmore » 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.« less
Cole, Tim J; Singhal, Atul; Fewtrell, Mary S; Wells, Jonathan Ck
2016-10-01
Early rapid weight gain is associated with later overweight, which implies that weight centile crossing tracks over time. Centile crossing is defined in terms of the change or deviation in weight z score during 1 mo, and the correlations between successive deviations are explored at different ages. Two Cambridge (United Kingdom) growth cohorts were used: Widdowson (1094 infants born during 1959-1965) and the Cambridge Infant Growth Study (CIGS; 255 infants born during 1984-1987), each with weights measured monthly in the first year. Weights were converted to WHO age- and sex-adjusted z scores, deviations were calculated as the change in z score between adjacent measurement occasions, and the correlations between deviations were studied. In both cohorts, the correlations between successive monthly deviations were positive in the first 6 mo and highest at ages 3-4 mo (r = 0.3, P < 0.0001), whereas after 6 mo they were negative and were lowest at ages 10-11 mo (r = -0.3, P < 0.0001), with the correlation decreasing linearly with age between these extremes. Thus, during the first 6 mo of age, infants crossing centiles in 1 mo tended to continue crossing centiles in the same direction the following month, whereas after 6 mo they tended to cross back again. This represents positive and negative feedback, respectively. At age 12 mo, the correlation was close to zero, which suggests an infant-child transition in growth. The results confirm that weight centile crossing tracks over time, with the correlations between successive periods that change with age suggesting a complex feedback mechanism underlying infant growth. This may throw light on the link between early rapid weight gain and later overweight. Clinically, the correlations indicate that when predicting future weight from current weight, recent centile crossing affects the prediction in an age-dependent manner.
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Normal correspondence of tectal maps for saccadic eye movements in strabismus
Economides, John R.; Adams, Daniel L.
2016-01-01
The superior colliculus is a major brain stem structure for the production of saccadic eye movements. Electrical stimulation at any given point in the motor map generates saccades of defined amplitude and direction. It is unknown how this saccade map is affected by strabismus. Three macaques were raised with exotropia, an outwards ocular deviation, by detaching the medial rectus tendon in each eye at age 1 mo. The animals were able to make saccades to targets with either eye and appeared to alternate fixation freely. To probe the organization of the superior colliculus, microstimulation was applied at multiple sites, with the animals either free-viewing or fixating a target. On average, microstimulation drove nearly conjugate saccades, similar in both amplitude and direction but separated by the ocular deviation. Two monkeys showed a pattern deviation, characterized by a systematic change in the relative position of the two eyes with certain changes in gaze angle. These animals' saccades were slightly different for the right eye and left eye in their amplitude or direction. The differences were consistent with the animals' underlying pattern deviation, measured during static fixation and smooth pursuit. The tectal map for saccade generation appears to be normal in strabismus, but saccades may be affected by changes in the strabismic deviation that occur with different gaze angles. PMID:27605534
NASA Astrophysics Data System (ADS)
Scarpato, D. J.
2016-02-01
Slope construction in shale can present some interesting challenges for geotechnical design engineers and contractors alike. There are challenges that can be expected and designed for; however, all too frequently, such challenges manifest themselves as "surprises" in the field. Common constructibility challenges can include drill hole deviation during drilling for controlled blasting; and, excavation slope instability arising from inconsistent perimeter control drilling. Drill hole deviation results from the cumulative effects from both drilling mechanics and rock mass conditions. Once a hole has initiated the deviation trajectory, it is difficult to rectify drill steel position. Although such challenges are not necessarily unique to shale, they are often exacerbated by weak, weathered and transversely isotropic nature of bedrock conditions. All too often, the working assumption is that shale is "soft" and easily excavatable; however, this blanket assumption can prove to be costly. This paper is intended to provide design professionals and contractors with the practical considerations needed to avoid the "surprises" associated with drill hole deviation, and minimize the potential for costly claims.
NASA Astrophysics Data System (ADS)
Zhang, Wei; Qi, Yafei; Huang, Wei; Gao, Yubo
2017-01-01
The investigation on free-surface impact of projectiles has last for more than one hundred years due to its noticeable significance on improving defensive weapon technology. Laboratory-scaled water entry experiments for trajectory stability had been performed with four kinds of projectiles at a speed range of 20˜200 m/s. The nose shapes of the cylindrical projectiles were designed into flat, ogive, hemi-sphere and cone to make comparisons on the trajectory deviation when they were launched into water at a certain angle of 0˜20°. Two high-speed cameras positioned orthogonal to each other and normal to the water tank were employed to capture the entire process of projectiles' penetration. From the experimental results, the consecutive images in two planes were presented to display the general process of the trajectory deviation. Compared with the effect of impact velocities and nose shape on trajectory deviation, it merited conclude that flat projectiles had a better trajectory stability, while ogival projectiles experienced the largest attitude change. The characteristics of pressure waves were also investigated.
Li, Yinghui; Chen, Lixin; Zhu, Jinhan; Wang, Bin; Liu, Xiaowei
2017-07-01
A quantitative method based on the electronic portal imaging system (EPID) and film was developed for MLC position and speed testing; this method was used for three MLC types (Millennium, MLCi, and Agility MLC). To determine the leaf position, a picket fence designed by the dynamic (DMLC) model was used. The full-width half-maximum (FWHM) values of each gap measured by EPID and EBT3 were converted to the gap width using the FWHM versus nominal gap width relationship. The algorithm developed for the picket fence analysis was able to quantify the gap width, the distance between gaps, and each individual leaf position. To determine the leaf speed, a 0.5 × 20 cm 2 MLC-defined sliding gap was applied across a 14 × 20 cm 2 symmetry field. The linacs ran at a fixed-dose rate. The use of different monitor units (MUs) for this test led to different leaf speeds. The effect of leaf transmission was considered in a speed accuracy analysis. The difference between the EPID and film results for the MLC position is less than 0.1 mm. For the three MLC types, twice the standard deviation (2 SD) is provided; 0.2, 0.4, and 0.4 mm for gap widths of three MLC types, and 0.1, 0.2, and 0.2 mm for distances between gaps. The individual leaf positions deviate from the preset positions within 0.1 mm. The variations in the speed profiles for the EPID and EBT3 results are consistent, but the EPID results are slightly better than the film results. Different speeds were measured for each MLC type. For all three MLC types, speed errors increase with increasing speed. The analysis speeds deviate from the preset speeds within approximately 0.01 cm s -1 . This quantitative analysis of MLC position and speed provides an intuitive evaluation for MLC quality assurance (QA). © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
76 FR 26606 - Drawbridge Operation Regulation; Illinois Waterway, Near Morris, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-09
... allow removal of the existing lift span and installation of the replacement lift span. This deviation...-navigation position for eighty-four hours while the existing lift span is removed and the replacement lift...
76 FR 40237 - Drawbridge Operation Regulation; Illinois Waterway, Near Morris, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
... allow removal of the existing lift span and installation of the replacement lift span. This deviation... position for eighty-four hours while the existing lift span is removed and the replacement lift span is...
Numerical Investigations of Slip Phenomena in Centrifugal Compressor Impellers
NASA Astrophysics Data System (ADS)
Huang, Jeng-Min; Luo, Kai-Wei; Chen, Ching-Fu; Chiang, Chung-Ping; Wu, Teng-Yuan; Chen, Chun-Han
2013-03-01
This study systematically investigates the slip phenomena in the centrifugal air compressor impellers by CFD. Eight impeller blades for different specific speeds, wrap angles and exit blade angles are designed by compressor design software to analyze their flow fields. Except for the above three variables, flow rate and number of blades are the other two. Results show that the deviation angle decreases as the flow rate increases. The specific speed is not an important parameter regarding deviation angle or slip factor for general centrifugal compressor impellers. The slip onset position is closely related to the position of the peak value in the blade loading factor distribution. When no recirculation flow is present at the shroud, the variations of slip factor under various flow rates are mainly determined by difference between maximum blade angle and exit blade angle, Δβmax-2. The solidity should be of little importance to slip factor correlations in centrifugal compressor impellers.
Expected distributions of root-mean-square positional deviations in proteins.
Pitera, Jed W
2014-06-19
The atom positional root-mean-square deviation (RMSD) is a standard tool for comparing the similarity of two molecular structures. It is used to characterize the quality of biomolecular simulations, to cluster conformations, and as a reaction coordinate for conformational changes. This work presents an approximate analytic form for the expected distribution of RMSD values for a protein or polymer fluctuating about a stable native structure. The mean and maximum of the expected distribution are independent of chain length for long chains and linearly proportional to the average atom positional root-mean-square fluctuations (RMSF). To approximate the RMSD distribution for random-coil or unfolded ensembles, numerical distributions of RMSD were generated for ensembles of self-avoiding and non-self-avoiding random walks. In both cases, for all reference structures tested for chains more than three monomers long, the distributions have a maximum distant from the origin with a power-law dependence on chain length. The purely entropic nature of this result implies that care must be taken when interpreting stable high-RMSD regions of the free-energy landscape as "intermediates" or well-defined stable states.
Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation.
Helms, Gunther; Dathe, Henning; Dechent, Peter
2008-03-01
From the half-angle substitution of trigonometric terms in the Ernst equation, rational approximations of the flip angle dependence of the FLASH signal can be derived. Even the rational function of the lowest order was in good agreement with the experiment for flip angles up to 20 degrees . Three-dimensional maps of the signal amplitude and longitudinal relaxation rates in human brain were obtained from eight subjects by dual-angle measurements at 3T (nonselective 3D-FLASH, 7 degrees and 20 degrees flip angle, TR = 30 ms, isotropic resolution of 0.95 mm, each 7:09 min). The corresponding estimates of T1 and signal amplitude are simple algebraic expressions and deviated about 1% from the exact solution. They are ill-conditioned to estimate the local flip angle deviation but can be corrected post hoc by division of squared RF maps obtained by independent measurements. Local deviations from the nominal flip angles strongly affected the relaxation estimates and caused considerable blurring of the T1 histograms. (c) 2008 Wiley-Liss, Inc.
Post-Kerr black hole spectroscopy
NASA Astrophysics Data System (ADS)
Glampedakis, Kostas; Pappas, George; Silva, Hector O.; Berti, Emanuele
2017-09-01
One of the central goals of the newborn field of gravitational wave astronomy is to test gravity in the highly nonlinear, strong field regime characterizing the spacetime of black holes. In particular, "black hole spectroscopy" (the observation and identification of black hole quasinormal mode frequencies in the gravitational wave signal) is expected to become one of the main tools for probing the structure and dynamics of Kerr black holes. In this paper we take a significant step toward that goal by constructing a "post-Kerr" quasinormal mode formalism. The formalism incorporates a parametrized but general perturbative deviation from the Kerr metric and exploits the well-established connection between the properties of the spacetime's circular null geodesics and the fundamental quasinormal mode to provide approximate, eikonal limit formulas for the modes' complex frequencies. The resulting algebraic toolkit can be used in waveform templates for ringing black holes with the purpose of measuring deviations from the Kerr metric. As a first illustrative application of our framework, we consider the Johannsen-Psaltis deformed Kerr metric and compute the resulting deviation in the quasinormal mode frequency relative to the known Kerr result.
Isaksen, Jonas; Leber, Remo; Schmid, Ramun; Schmid, Hans-Jakob; Generali, Gianluca; Abächerli, Roger
2017-02-01
The first-order high-pass filter (AC coupling) has previously been shown to affect the ECG for higher cut-off frequencies. We seek to find a systematic deviation in computer measurements of the electrocardiogram when the AC coupling with a 0.05 Hz first-order high-pass filter is used. The standard 12-lead electrocardiogram from 1248 patients and the automated measurements of their DC and AC coupled version were used. We expect a large unipolar QRS-complex to produce a deviation in the opposite direction in the ST-segment. We found a strong correlation between the QRS integral and the offset throughout the ST-segment. The coefficient for J amplitude deviation was found to be -0.277 µV/(µV⋅s). Potential dangerous alterations to the diagnostically important ST-segment were found. Medical professionals and software developers for electrocardiogram interpretation programs should be aware of such high-pass filter effects since they could be misinterpreted as pathophysiology or some pathophysiology could be masked by these effects. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Diameter effect on stress-wave evaluation of modulus of elasticity of logs
Xiping Wang; Robert J. Ross; Brian K. Brashaw; John Punches; John R. Erickson; John W. Forsman; Roy E. Pellerin
2004-01-01
Recent studies on nondestructive evaluation (NDE) of logs have shown that a longitudinal stress-wave method can be used to nondestructively evaluate the modulus of elasticity (MOE) of logs. A strong relationship has been found between stress-wave MOE and static MOE of logs, but a significant deviation was observed between stress-wave and static values. The objective of...
Diameter effect on stress-wave evaluation of modulus of elasticity of logs
Xiping Wang; Robert J. Ross; Brian K. Brashaw; John R. Erickson; John W. Forsman; Roy Pellerin
2003-01-01
Recent studies on nondestructive evaluation (NDE) of logs have shown that a longitudinal stress-wave method can be used to nondestructively evaluate the modulus of elasticity (MOE) of logs. A strong relationship has been found between stress-wave MOE and static MOE of logs, but a significant deviation was observed between stress-wave and static values. The objective of...
"Chemical contraction" in rubidium-bismuth melts
NASA Astrophysics Data System (ADS)
Khairulin, R. A.; Abdullaev, R. N.; Stankus, S. V.
2017-10-01
The density and thermal expansion of liquid rubidium and rubidium-bismuth alloy containing 25.0 at % Bi were measured by the gamma-ray attenuation technique at temperatures from liquidus to 1000 K. The results of this study were compared with the data obtained by other authors. The molar volume of the Rb75Bi25 melt strongly deviates from the additivity rule for ideal solutions.
Dynamics-Enabled Nanoelectromechanical Systems (NEMS) Oscillators
2014-06-01
it becomes strongly nonlinear, and thus constitutes an archetypal candidate for nonlinear engineering • its fundamental resonant frequency...width of spectral peaks of atomic force microscopy (AFM) resonators as they are brought close to a surface. 39 Approved for public release...alternating current AD Allan Deviation AFM atomic force microscopy AFRL Air Force Research Laboratory AlN aluminum nitride APN Anomalous Phase
[A new method to test vertical ocular deviations using perilimbal light reflexes].
Breyer, Armin; Rütsche, Adrian; Gampe, Elisabeth; Mojon, Daniel S
2003-03-01
To develop a new diagnostic technique to determine vertical ocular deviations when the center of the pupil is covered by swollen eyelids in up- and downgaze. In upgaze (downgaze) the reflex of a diagnostic lamp held at about 50 cm distance from the patient is observed on the lower (upper) limbus. In the case of an asymmetric reflex, prisms are used to obtain symmetrical reflexes. The amount of prisms indicates the size of the vertical misalignment. In five healthy volunteers, the angles of vertical changes of gaze position were plotted against the prism size needed to recenter the perilimbal reflex. There was a linear correlation between the amount of upgaze changes in degrees and the strength of prisms used for compensation in degrees. This linear correlation was also found in downgaze. For both the correlation coefficient was r = 0.98 +/- 0.01. In upgaze the slope of the average regression line was 0.55 +/- 2.3 degrees, in downgaze - 4.1 +/- 0.8 degrees. A prism of 1 degrees corresponds in upgaze to a vertical deviation of about 1.3 +/- 0.14 degrees, in downgaze to a deviation of about 1.1 +/- 0.07 degrees. These results demonstrate that the perilimbal light reflex test is suitable for measuring simulated vertical ocular deviations. Therefore, the test may also be used in patients with vertical deviations who cannot be measured with classical methods. The method is more exact for measurements in upgaze.
The Mott transition in the strong coupling perturbation theory
NASA Astrophysics Data System (ADS)
Sherman, A.
2015-01-01
Using the strong coupling diagram technique a self-consistent equation for the electron Green's function is derived for the repulsive Hubbard model. Terms of two lowest orders of the ratio of the bandwidth Δ to the Hubbard repulsion U are taken into account in the irreducible part of the Larkin equation. The obtained equation is shown to retain causality and reduces to Green's function of uncorrelated electrons in the limit U → 0. Calculations were performed for the semi-elliptical initial band. It is shown that the approximation describes the Mott transition, which occurs at Uc =√{ 3 } Δ / 2. This value coincides with that obtained in the Hubbard-III approximation. At half-filling, for 0 < U
Iutaka, Natalia A; Grochowski, Rubens A; Kasahara, Niro
2017-01-01
To evaluate the correlation between visual field index (VFI) and both structural and functional measures of the optic disc in primary open angle glaucoma patients and suspects. In this retrospective study, 162 glaucoma patients and suspects underwent standard automated perimetry (SAP), retinography, and retinal nerve fiber layer (RNFL) measurement. The optic disc was stratified according to the vertical cup/disc ratio (C/D) and sorted by the disc damage likelihood scale (DDLS). RNFL was measured with the optical coherence tomography. The VFI perimetry was correlated with the mean deviation (MD) and pattern standard deviation (PSD) obtained by SAP, and structural parameters by Pearson's correlation coefficients. VFI displayed strong correlation with MD ( R = 0.959) and PSD ( R = -0.744). The linear correlations between VFI and structural measures including C/D ( R = -0.179, P = 0.012), DDLS ( R = -0.214, P = 0.006), and RNFL ( R = 0.416, P < 0.001) were weak but statistically significant. VFI showed a strong correlation with MD and PSD but demonstrated a weak correlation with structural measures. It can possibly be used as a marker for functional impairment severity in patients with glaucoma.
Underwater auditory localization by a swimming harbor seal (Phoca vitulina).
Bodson, Anais; Miersch, Lars; Mauck, Bjoern; Dehnhardt, Guido
2006-09-01
The underwater sound localization acuity of a swimming harbor seal (Phoca vitulina) was measured in the horizontal plane at 13 different positions. The stimulus was either a double sound (two 6-kHz pure tones lasting 0.5 s separated by an interval of 0.2 s) or a single continuous sound of 1.2 s. Testing was conducted in a 10-m-diam underwater half circle arena with hidden loudspeakers installed at the exterior perimeter. The animal was trained to swim along the diameter of the half circle and to change its course towards the sound source as soon as the signal was given. The seal indicated the sound source by touching its assumed position at the board of the half circle. The deviation of the seals choice from the actual sound source was measured by means of video analysis. In trials with the double sound the seal localized the sound sources with a mean deviation of 2.8 degrees and in trials with the single sound with a mean deviation of 4.5 degrees. In a second experiment minimum audible angles of the stationary animal were found to be 9.8 degrees in front and 9.7 degrees in the back of the seal's head.
Wu, Zhijin; Liu, Dongmei; Sui, Yunxia
2008-02-01
The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.
Defining the Role of ATP Hydrolysis in Mitotic Segregation of Bacterial Plasmids
Ah-Seng, Yoan; Rech, Jérôme; Lane, David; Bouet, Jean-Yves
2013-01-01
Hydrolysis of ATP by partition ATPases, although considered a key step in the segregation mechanism that assures stable inheritance of plasmids, is intrinsically very weak. The cognate centromere-binding protein (CBP), together with DNA, stimulates the ATPase to hydrolyse ATP and to undertake the relocation that incites plasmid movement, apparently confirming the need for hydrolysis in partition. However, ATP-binding alone changes ATPase conformation and properties, making it difficult to rigorously distinguish the substrate and cofactor roles of ATP in vivo. We had shown that mutation of arginines R36 and R42 in the F plasmid CBP, SopB, reduces stimulation of SopA-catalyzed ATP hydrolysis without changing SopA-SopB affinity, suggesting the role of hydrolysis could be analyzed using SopA with normal conformational responses to ATP. Here, we report that strongly reducing SopB-mediated stimulation of ATP hydrolysis results in only slight destabilization of mini-F, although the instability, as well as an increase in mini-F clustering, is proportional to the ATPase deficit. Unexpectedly, the reduced stimulation also increased the frequency of SopA relocation over the nucleoid. The increase was due to drastic shortening of the period spent by SopA at nucleoid ends; average speed of migration per se was unchanged. Reduced ATP hydrolysis was also associated with pronounced deviations in positioning of mini-F, though time-averaged positions changed only modestly. Thus, by specifically targeting SopB-stimulated ATP hydrolysis our study reveals that even at levels of ATPase which reduce the efficiency of splitting clusters and the constancy of plasmid positioning, SopB still activates SopA mobility and plasmid positioning, and sustains near wild type levels of plasmid stability. PMID:24367270
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wootton, L; Kudchadker, R; Lee, A
Purpose: To evaluate the performance characteristics of plastic scintillation detectors (PSDs) in an in vivo environment for external beam radiation, and to establish the usefulness and ease of implementation of a PSD based in vivo dosimetry system for routine clinical use. Methods: A five patient IRB approved in vivo dosimetry study was performed. Five patients with prostate cancer were enrolled and PSDs were used to monitor rectal wall dose and verify the delivered dose for approximately two fractions each week over the course of their treatment (approximately fourteen fractions), resulting in a total of 142 in vivo measurements. A setmore » of two PSDs was fabricated for each patient. At each monitored fraction the PSDs were attached to the anterior surface of an endorectal balloon used to immobilize the patient's prostate during treatment. A CT scan was acquired with a CTon- rails linear accelerator to localize the detectors and to calculate the dose expected to be delivered to the detectors. Each PSD acquired data in 10 second intervals for the duration of the treatment. The deviation between expected and measured cumulative dose was calculated for each detector for each fraction, and averaged over each patient and the patient population as a whole. Results: The average difference between expected dose and measured dose ranged from -3.3% to 3.3% for individual patients, with standard deviations between 5.6% and 7.1% for four of the patients. The average difference for the entire population was -0.4% with a standard deviation of 2.8%. The detectors were well tolerated by the patients and the system did not interrupt the clinical workflow. Conclusion: PSDs perform well as in vivo dosimeters, exhibiting good accuracy and precision. This, combined with the practicability of using such a system, positions the PSD as a strong candidate for clinical in vivo dosimetry in the future. This work supported in part by the National Cancer Institute through an R01 grant (CA120198-01A2) and by the American Legion Auxiliary through the American Auxiliary Fellowship in Cancer Research.« less
High-Resolution Study of the First Stretching Overtones of H3Si79Br.
Ceausu; Graner; Bürger; Mkadmi; Pracna; Lafferty
1998-11-01
The Fourier transform infrared spectrum of monoisotopic H3Si79Br (resolution 7.7 x 10(-3) cm-1) was studied from 4200 to 4520 cm-1, in the region of the first overtones of the Si-H stretching vibration. The investigation of the spectrum revealed the presence of two band systems, the first consisting of one parallel (nu0 = 4340.2002 cm-1) and one perpendicular (nu0 = 4342.1432 cm-1) strong component, and the second of one parallel (nu0 = 4405.789 cm-1) and one perpendicular (nu0 = 4416.233 cm-1) weak component. The rovibrational analysis shows strong local perturbations for both strong and weak systems. Seven hundred eighty-one nonzero-weighted transitions belonging to the strong system [the (200) manifold in the local mode picture] were fitted to a simple model involving a perpendicular component interacting by a weak Coriolis resonance with a parallel component. The most severely perturbed transitions (whose ||obs-calc || values exceeded 3 x 10(-3) cm-1) were given zero weights. The standard deviations of the fit were 1.0 x 10(-3) and 0.69 x 10(-3) cm-1 for the parallel and the perpendicular components, respectively. The weak band system, severely perturbed by many "dark" perturbers, was fitted to a model involving one parallel and one perpendicular band, connected by a Coriolis-type resonance. The K" . DeltaK = +10 to +18 subbands of the perpendicular component, which showed very high observed - calculated values ( approximately 0.5 cm-1), were excluded from this calculation. The standard deviations of the fit were 11 x 10(-3) and 13 x 10(-3) cm-1 for the parallel and the perpendicular components, respectively. Copyright 1998 Academic Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Katsumasa; Shioyama, Yoshiyuki; Nomoto, Satoru
2007-05-01
Purpose: The voluntary breath-hold (BH) technique is a simple method to control the respiration-related motion of a tumor during irradiation. However, the abdominal and chest wall position may not be accurately reproduced using the BH technique. The purpose of this study was to examine whether visual feedback can reduce the fluctuation in wall motion during BH using a new respiratory monitoring device. Methods and Materials: We developed a laser-based BH monitoring and visual feedback system. For this study, five healthy volunteers were enrolled. The volunteers, practicing abdominal breathing, performed shallow end-expiration BH (SEBH), shallow end-inspiration BH (SIBH), and deep end-inspirationmore » BH (DIBH) with or without visual feedback. The abdominal and chest wall positions were measured at 80-ms intervals during BHs. Results: The fluctuation in the chest wall position was smaller than that of the abdominal wall position. The reproducibility of the wall position was improved by visual feedback. With a monitoring device, visual feedback reduced the mean deviation of the abdominal wall from 2.1 {+-} 1.3 mm to 1.5 {+-} 0.5 mm, 2.5 {+-} 1.9 mm to 1.1 {+-} 0.4 mm, and 6.6 {+-} 2.4 mm to 2.6 {+-} 1.4 mm in SEBH, SIBH, and DIBH, respectively. Conclusions: Volunteers can perform the BH maneuver in a highly reproducible fashion when informed about the position of the wall, although in the case of DIBH, the deviation in the wall position remained substantial.« less
Populin, Luis C; Tollin, Daniel J; Yin, Tom C T
2004-10-01
We examined the motor error hypothesis of visual and auditory interaction in the superior colliculus (SC), first tested by Jay and Sparks in the monkey. We trained cats to direct their eyes to the location of acoustic sources and studied the effects of eye position on both the ability of cats to localize sounds and the auditory responses of SC neurons with the head restrained. Sound localization accuracy was generally not affected by initial eye position, i.e., accuracy was not proportionally affected by the deviation of the eyes from the primary position at the time of stimulus presentation, showing that eye position is taken into account when orienting to acoustic targets. The responses of most single SC neurons to acoustic stimuli in the intact cat were modulated by eye position in the direction consistent with the predictions of the "motor error" hypothesis, but the shift accounted for only two-thirds of the initial deviation of the eyes. However, when the average horizontal sound localization error, which was approximately 35% of the target amplitude, was taken into account, the magnitude of the horizontal shifts in the SC auditory receptive fields matched the observed behavior. The modulation by eye position was not due to concomitant movements of the external ears, as confirmed by recordings carried out after immobilizing the pinnae of one cat. However, the pattern of modulation after pinnae immobilization was inconsistent with the observations in the intact cat, suggesting that, in the intact animal, information about the position of the pinnae may be taken into account.
Refractivity of Molten Nitrates and Chlorides: Binary Mixtures Containing Cesium Ions
NASA Astrophysics Data System (ADS)
Uchiyama, Yohji; Karawacki, Ernest
1981-05-01
By using an interferometric technique, the refractive index of some molten salt mixtures containing Cs+ ions was measured with high accuracy: (Li-Cs)NO3, (Na-Cs)NO3, (Ag-Cs)NO3, (Li-Cs)Cl, and also pure RbCl. The isotherms of molar refractivity show a small negative deviation from additivity in the (Li-Cs)NO3 and (Li-Cs)Cl systems and a positive deviation in the (Ag-Cs)NO3 mixture. A tentative attempt was made to relate the excess molar refractivities with the absorption bands of the ions.
A passive autofocus system by using standard deviation of the image on a liquid lens
NASA Astrophysics Data System (ADS)
Rasti, Pejman; Kesküla, Arko; Haus, Henry; Schlaak, Helmut F.; Anbarjafari, Gholamreza; Aabloo, Alvo; Kiefer, Rudolf
2015-04-01
Today most of applications have a small camera such as cell phones, tablets and medical devices. A micro lens is required in order to reduce the size of the devices. In this paper an auto focus system is used in order to find the best position of a liquid lens without any active components such as ultrasonic or infrared. In fact a passive auto focus system by using standard deviation of the images on a liquid lens which consist of a Dielectric Elastomer Actuator (DEA) membrane between oil and water is proposed.
Diagnostics for insufficiencies of posterior calculations in Bayesian signal inference.
Dorn, Sebastian; Oppermann, Niels; Ensslin, Torsten A
2013-11-01
We present an error-diagnostic validation method for posterior distributions in Bayesian signal inference, an advancement of a previous work. It transfers deviations from the correct posterior into characteristic deviations from a uniform distribution of a quantity constructed for this purpose. We show that this method is able to reveal and discriminate several kinds of numerical and approximation errors, as well as their impact on the posterior distribution. For this we present four typical analytical examples of posteriors with incorrect variance, skewness, position of the maximum, or normalization. We show further how this test can be applied to multidimensional signals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velec, Michael, E-mail: michael.velec@rmp.uhn.on.ca; Institute of Medical Science, University of Toronto, Toronto, ON; Moseley, Joanne L.
2012-07-15
Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between themore » accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.« less
NASA Astrophysics Data System (ADS)
Zhou, H.; Chen, B.; Han, Z. X.; Zhang, F. Q.
2009-05-01
The study on probability density function and distribution function of electricity prices contributes to the power suppliers and purchasers to estimate their own management accurately, and helps the regulator monitor the periods deviating from normal distribution. Based on the assumption of normal distribution load and non-linear characteristic of the aggregate supply curve, this paper has derived the distribution of electricity prices as the function of random variable of load. The conclusion has been validated with the electricity price data of Zhejiang market. The results show that electricity prices obey normal distribution approximately only when supply-demand relationship is loose, whereas the prices deviate from normal distribution and present strong right-skewness characteristic. Finally, the real electricity markets also display the narrow-peak characteristic when undersupply occurs.
NASA Astrophysics Data System (ADS)
Itoh, Tamitake; Yamamoto, Yuko S.; Tamaru, Hiroharu; Biju, Vasudevanpillai; Murase, Norio; Ozaki, Yukihiro
2013-06-01
We find unique properties accompanying surface-enhanced fluorescence (SEF) from dye molecules adsorbed on Ag nanoparticle aggregates, which generate surface-enhanced Raman scattering. The properties are observed in excitation laser energy dependence of SEF after excluding plasmonic spectral modulation in SEF. The unique properties are large blue shifts of fluorescence spectra, deviation of ratios between anti-Stokes SEF intensity and Stokes from those of normal fluorescence, super-broadening of Stokes spectra, and returning to original fluorescence by lower energy excitation. We elucidate that these properties are induced by electromagnetic enhancement of radiative decay rates exceeding the vibrational relaxation rates within an electronic excited state, which suggests that molecular electronic dynamics in strong plasmonic fields can be largely deviated from that in free space.
A massive pulsar in a compact relativistic binary.
Antoniadis, John; Freire, Paulo C C; Wex, Norbert; Tauris, Thomas M; Lynch, Ryan S; van Kerkwijk, Marten H; Kramer, Michael; Bassa, Cees; Dhillon, Vik S; Driebe, Thomas; Hessels, Jason W T; Kaspi, Victoria M; Kondratiev, Vladislav I; Langer, Norbert; Marsh, Thomas R; McLaughlin, Maura A; Pennucci, Timothy T; Ransom, Scott M; Stairs, Ingrid H; van Leeuwen, Joeri; Verbiest, Joris P W; Whelan, David G
2013-04-26
Many physically motivated extensions to general relativity (GR) predict substantial deviations in the properties of spacetime surrounding massive neutron stars. We report the measurement of a 2.01 ± 0.04 solar mass (M⊙) pulsar in a 2.46-hour orbit with a 0.172 ± 0.003 M⊙ white dwarf. The high pulsar mass and the compact orbit make this system a sensitive laboratory of a previously untested strong-field gravity regime. Thus far, the observed orbital decay agrees with GR, supporting its validity even for the extreme conditions present in the system. The resulting constraints on deviations support the use of GR-based templates for ground-based gravitational wave detectors. Additionally, the system strengthens recent constraints on the properties of dense matter and provides insight to binary stellar astrophysics and pulsar recycling.
Coercivity of die upset NdFeB magnets: A strong pinning model
NASA Astrophysics Data System (ADS)
Pinkerton, F. E.; Fuerst, C. D.
1990-09-01
We show that the temperature dependence of the intrinsic coercivity Hci( T) between 5 and 600 K in a die-upset NdFeB magnet is in good agreement with a model for strong domain wall pinning by a random array of pinning sites proposed by Gaunt [P. Gaunt, Phil. Mag. B48 (1983) 261]. The model includes both the temperature dependence of the intrinsic magnetic properties of the Nd 2Fe 14B phase and the effects of thermal activation of domain walls over the pinning barrier. The pinning sites are modeled as nonmagnetic planar inhomogeneities at the boundaries aetween platelet-shaped Nd 2Fe 14B grains. We develop an expression for the maximum pinning force per site, f, and derive the model prediction that (H ci/γH A) {1}/{2} varies linearly with (T/γ) {2}/{3}, where HA and γ are the magnetocrystalline anisotropy and the domain wall energy per unit area of the Nd 2Fe 14B phase, respectively. The model is in good agreement with the observed Hci values over a broad temperature range from 200 to 477 K. Deviations from the model below 200 K are an artifact of the axial-to-conical spin reorientation in Nd 2Fe 14B at low temperature. Deviations at high temperature most likely occur because the strong pinning model is no longer valid close to the Curie temperature (585 K).
NASA Astrophysics Data System (ADS)
Valeev, R. G.; Romanov, E. A.; Vorobiev, V. L.; Mukhgalin, V. V.; Kriventsov, V. V.; Chukavin, A. I.; Robouch, B. V.
2015-02-01
Interest to ZnSxSe1-x alloys is due to their band-gap tunability varying S and Se content. Films of ZnSxSe1-x were grown evaporating ZnS and ZnSe powder mixtures onto SiO2, NaCl, Si and ITO substrates using an original low-cost method. X-ray diffraction patterns and Raman spectroscopy, show that the lattice structure of these films is cubic ZnSe-like, as S atoms replace Se and film compositions have their initial S/Se ratio. Optical absorption spectra show that band gap values increase from 2.25 to 3 eV as x increases, in agreement with the literature. Because S atomic radii are smaller than Se, EXAFS spectra confirm that bond distances and Se coordination numbers decrease as the Se content decreases. The strong deviation from linearity of ZnSe coordination numbers in the ZnSxSe1-x indicate that within this ordered crystal structure strong site occupation preferences occur in the distribution of Se and S ions. The behavior is quantitatively confirmed by the strong deviation from the random Bernoulli distribution of the three sight occupation preference coefficients of the strained tetrahedron model. Actually, the ternary ZnSxSe1-x system is a bi-binary (ZnS+ZnSe) alloy with evanescent formation of ternary configurations throughout the x-range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsi, Wen C.; Fagundes, Marcio; Zeidan, Omar
Purpose: To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. Methods: TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markersmore » were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. Results: A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Conclusions: Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification can be perfomed reliably and reproducibly for proton therapy in prostate cancer.« less
Hsi, Wen C; Fagundes, Marcio; Zeidan, Omar; Hug, Eugen; Schreuder, Niek
2013-05-01
To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markers were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification can be perfomed reliably and reproducibly for proton therapy in prostate cancer.
Cholesteric pitch transitions induced by mechanical strain.
Lelidis, I; Barbero, G; Alexe-Ionescu, A L
2013-02-01
We investigate thickness and surface anchoring strength influence on pitch transitions in a planar cholesteric liquid crystal layer. The cholesteric-nematic transition is also investigated. We assume planar boundary conditions, with strong anchoring strength at one interface and weak anchoring strength at the other. The surface anchoring energy we consider to describe the deviation of the surface twist angle from the easy axis induced by a bulk deformation is a parabolic potential or Rapini and Papoular periodic potential, respectively. We show that under strain, all pitch transitions take place at a critical thickness that is equal to the quarter of the natural cholesteric pitch. The latter result does not depend on the anchoring strength, the particular surface potential, or material properties. The twist angle on the limiting surface characterized by weak anchoring varies with strain either by slipping and or in a discontinuous manner according to the thickness of the sample. The position of the bifurcation point depends only on the ratio of the extrapolation length over the layer thickness, but its value is model dependent. Multistability and multiplicity of the transition are discussed.
NASA Technical Reports Server (NTRS)
Wang, J. R.; Shiue, J. C.; Engman, E. T.; Rusek, M.; Steinmeier, C.
1986-01-01
An experiment was conducted from an L-band SAR aboard Space Shuttle Challenger in October 1984 to study the microwave backscatter dependence on soil moisture, surface roughness, and vegetation cover. The results based on the analyses of an image obtained at 21-deg incidence angle show a positive correlatlion between scattering coefficient and soil moisture content, with a sensitivity comparable to that derived from the ground radar measurements reported by Ulaby et al. (1978). The surface roughness strongly affects the microwave backscatter. A factor of two change in the standard deviation of surface roughness height gives a corresponding change of about 8 dB in the scattering coefficient. The microwave backscatter also depends on the vegetation types. Under the dry soil conditions, the scattering coefficient is observed to change from about -24 dB for an alfalfa or lettuce field to about -17 dB for a mature corn field. These results suggest that observations with a SAR system of multiple frequencies and polarizations are required to unravel the effects of soil moisture, surface roughness, and vegetation cover.
Gargallo, Raimundo; Hünenberger, Philippe H.; Avilés, Francesc X.; Oliva, Baldomero
2003-01-01
Molecular dynamics (MD) simulations of the activation domain of porcine procarboxypeptidase B (ADBp) were performed to examine the effect of using the particle-particle particle-mesh (P3M) or the reaction field (RF) method for calculating electrostatic interactions in simulations of highly charged proteins. Several structural, thermodynamic, and dynamic observables were derived from the MD trajectories, including estimated entropies and solvation free energies and essential dynamics (ED). The P3M method leads to slightly higher atomic positional fluctuations and deviations from the crystallographic structure, along with somewhat lower values of the total energy and solvation free energy. However, the ED analysis of the system leads to nearly identical results for both simulations. Because of the strong similarity between the results, both methods appear well suited for the simulation of highly charged globular proteins in explicit solvent. However, the lower computational demand of the RF method in the present implementation represents a clear advantage over the P3M method. PMID:14500874
Changes in Income at Macro Level Predict Sex Ratio at Birth in OECD Countries.
Kanninen, Ohto; Karhula, Aleksi
2016-01-01
The human sex ratio at birth (SRB) is approximately 107 boys for every 100 girls. SRB was rising until the World War II and has been declining slightly after the 1950s in several industrial countries. Recent studies have shown that SRB varies according to exposure to disasters and socioeconomic conditions. However, it remains unknown whether changes in SRB can be explained by observable macro-level socioeconomic variables across multiple years and countries. Here we show that changes in disposable income at the macro level positively predict SRB in OECD countries. A one standard deviation increase in the change of disposable income is associated with an increase of 1.03 male births per 1000 female births. The relationship is possibly nonlinear and driven by extreme changes. The association varies from country to country being particular strong in Estonia. This is the first evidence to show that economic and social conditions are connected to SRB across countries at the macro level. This calls for further research on the effects of societal conditions on general characteristics at birth.
Hollar, David; Hobgood, Cherri; Foster, Beverly; Aleman, Marco; Sawning, Susan
2012-01-01
Positive attitudes towards teamwork among health care professionals are critical to patient safety. The purpose of this study is to describe the development and concurrent validation of a new instrument to measure attitudes towards healthcare teamwork that is generalizable across various populations of healthcare students. The Collaborative Healthcare Interdisciplinary Planning (CHIRP) scale was validated against the Readiness for Inter-Professional Learning Scale (RIPLS). Analyses included student (n = 266) demographics, ANOVA, internal consistency, factor analysis, and Rasch analysis. The two instruments correlated at r = .582. The CHIRP showed a multifactorial structure having excellent internal consistency (alpha = .850), with 25 of the 36 scale items loading onto a single Teamwork Attitudes factor. The RIPLS likewise had strong internal consistency (alpha = .796) and a three-factor structure, supporting previous studies of the instrument. However, Rasch analyses showed 14 (38.9%) of the 36 CHIRP items, but only four (21.1%) of the 19 RIPLS items remaining within the satisfactory standardized OUTFIT zone of 2.0 standard deviation units. We propose the 14 fitting items as a new, validated teamwork attitudes scale.
Wang, Taofeng; Li, Guangwu; Zhu, Liping; ...
2016-01-08
The dependence of correlations of neutron multiplicity ν and γ-ray multiplicity M γ in spontaneous fission of 252Cf on fragment mass A* and total kinetic energy (TKE) have been investigated by employing the ratio of M γ/ν and the form of M γ(ν). We show for the first time that M γ and ν have a complex correlation for heavy fragment masses, while there is a positive dependence of Mγ for light fragment masses and for near-symmetric mass splits. The ratio M γ/ν exhibits strong shell effects for neutron magic number N=50 and near doubly magic number shell closure atmore » Z=50 and N=82. The γ-ray multiplicity Mγ has a maximum for TKE=165-170 MeV. Above 170 MeV M γ(TKE) is approximately linear, while it deviates significantly from a linear dependence at lower TKE. The correlation between the average neutron and γ-ray multiplicities can be partly reproduced by model calculations.« less
VLBI observations to the APOD satellite
NASA Astrophysics Data System (ADS)
Sun, Jing; Tang, Geshi; Shu, Fengchun; Li, Xie; Liu, Shushi; Cao, Jianfeng; Hellerschmied, Andreas; Böhm, Johannes; McCallum, Lucia; McCallum, Jamie; Lovell, Jim; Haas, Rüdiger; Neidhardt, Alexander; Lu, Weitao; Han, Songtao; Ren, Tianpeng; Chen, Lue; Wang, Mei; Ping, Jinsong
2018-02-01
The APOD (Atmospheric density detection and Precise Orbit Determination) is the first LEO (Low Earth Orbit) satellite in orbit co-located with a dual-frequency GNSS (GPS/BD) receiver, an SLR reflector, and a VLBI X/S dual band beacon. From the overlap statistics between consecutive solution arcs and the independent validation by SLR measurements, the orbit position deviation was below 10 cm before the on-board GNSS receiver got partially operational. In this paper, the focus is on the VLBI observations to the LEO satellite from multiple geodetic VLBI radio telescopes, since this is the first implementation of a dedicated VLBI transmitter in low Earth orbit. The practical problems of tracking a fast moving spacecraft with current VLBI ground infrastructure were solved and strong interferometric fringes were obtained by cross-correlation of APOD carrier and DOR (Differential One-way Ranging) signals. The precision in X-band time delay derived from 0.1 s integration time of the correlator output is on the level of 0.1 ns. The APOD observations demonstrate encouraging prospects of co-location of multiple space geodetic techniques in space, as a first prototype.
Nonlinear Meridional Moisture Advection and the ENSO-Southern China Rainfall Teleconnection
NASA Astrophysics Data System (ADS)
Wang, Qiang; Cai, Wenju; Zeng, Lili; Wang, Dongxiao
2018-05-01
In the boreal cooler months of 2015, southern China (SC) experienced the largest rainfall since 1950, exceeding 4 times the standard deviation of SC rainfall. Although an El Niño typically induces a positive SC rainfall anomaly during these months, the unprecedented rainfall increase cannot be explained by the strong El Niño of 2015/2016, and the dynamics is unclear. Here we show that a nonlinear meridional moisture advection contributes substantially to the unprecedented rainfall increase. During cooler months of 2015, the meridional flow anomaly over the South China Sea region, which acts on an El Niño-induced anomalous meridional moisture gradient, is particularly large and is supported by an anomalous zonal sea surface temperature gradient over the northwestern Pacific, which recorded its largest value in 2015 since 1950. Our study highlights, for the first time, the importance of the nonlinear process associated with the combined impact of a regional sea surface temperature gradient and large-scale El Niño anomalies in forcing El Niño rainfall teleconnection.
Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard
2015-10-01
Flapless implant placement using surgical templates may guarantee predictable and esthetic results provided that preplanned implant positions are transfered precisely into surgical reality. The study aims to investigate the effect of three-dimensional accuracy in guided implant surgery on the esthetic outcome of single-tooth implants in the anterior maxilla. Single-tooth implants for delayed replacement of upper incisors were inserted in 27 patients using stereolithographic templates. Superimposition of postoperative cone beam computed tomography (CBCT) scans allowed assessment of positional inaccuracy at the implant shoulder and apex, as well as angular deviation. Objective evaluation of implant esthetics was performed after a mean follow-up of 2.3 years using the Pink Esthetic Score (PES). Mean deviation between planned and actual implant position was 0.84 mm at the implant shoulder and significantly correlated to average PES of 12 (p = .031). Inaccuracy toward the buccal side was most frequent (70%). Deviations ≥ 0.8 mm resulted in significantly worse implant esthetics (median PES: 9.5, interquartile range [IQR]: 8-11) compared with more accurate implant positions (median PES: 13, IQR: 12-13, p = .039). Positional inaccuracy is low in guided implant surgery, but may however significantly compromise implant esthetics in the anterior maxilla. © 2014 Wiley Periodicals, Inc.
Weksler, Natan; Velan, Gad J; Semionov, Michael; Gurevitch, Boris; Klein, Moti; Rozentsveig, Vsevolod; Rudich, Tzvia
2007-12-01
It is a common practice to the link low back pain with protruding disc even when neurological signs are absent. Because pain caused by sacroiliac joint dysfunction can mimic discogenic or radicular low back pain, we assumed that the diagnosis of sacroiliac joint dysfunction is frequently overlooked. To assess the incidence of sacroiliac joint dysfunction in patients with low back pain and positive disc findings on CT scan or MRI, but without claudication or objective neurological deficits. Fifty patients with low back pain and disc herniation, without claudication or neurological abnormalities such as decreased motor strength, sensory alterations or sphincter incontinence and with positive pain provocation tests for sacroiliac joint dysfunction were submitted to fluoroscopic diagnostic sacroiliac joint infiltration. The mean baseline VAS pain score was 7.8 +/- 1.77 (range 5-10). Thirty minutes after infiltration, the mean VAS score was 1.3 +/- 1.76 (median 0.000E+00 with an average deviation from median = 1.30) (P = 0.0002). Forty-six patients had a VAS score ranging from 0 to 3, 8 weeks after the fluoroscopic guided infiltration. There were no serious complications after treatment. An unanticipated motor block that required hospitalization was seen in four patients, lasting from 12 to 36 h. Sacroiliac joint dysfunction should be considered strongly in the differential diagnosis of low back pain in this group of patients.
Shu, Bao; Liu, Hui; Xu, Longwei; Qian, Chuang; Gong, Xiaopeng; An, Xiangdong
2018-04-14
For GPS medium-long baseline real-time kinematic (RTK) positioning, the troposphere parameter is introduced along with coordinates, and the model is ill-conditioned due to its strong correlation with the height parameter. For BeiDou Navigation Satellite System (BDS), additional difficulties occur due to its special satellite constellation. In fact, relative zenith troposphere delay (RZTD) derived from high-precision empirical zenith troposphere models can be introduced. Thus, the model strength can be improved, which is also called the RZTD-constrained RTK model. In this contribution, we first analyze the factors affecting the precision of BDS medium-long baseline RTK; thereafter, 15 baselines ranging from 38 km to 167 km in different troposphere conditions are processed to assess the performance of RZTD-constrained RTK. Results show that the troposphere parameter is difficult to distinguish from the height component, even with long time filtering for BDS-only RTK. Due to the lack of variation in geometry for the BDS geostationary Earth orbit satellite, the long convergence time of ambiguity parameters may reduce the height precision of GPS/BDS-combined RTK in the initial period. When the RZTD-constrained model was used in BDS and GPS/BDS-combined situations compared with the traditional RTK, the standard deviation of the height component for the fixed solution was reduced by 52.4% and 34.0%, respectively.
Liu, Hui; Xu, Longwei; Qian, Chuang; Gong, Xiaopeng; An, Xiangdong
2018-01-01
For GPS medium-long baseline real-time kinematic (RTK) positioning, the troposphere parameter is introduced along with coordinates, and the model is ill-conditioned due to its strong correlation with the height parameter. For BeiDou Navigation Satellite System (BDS), additional difficulties occur due to its special satellite constellation. In fact, relative zenith troposphere delay (RZTD) derived from high-precision empirical zenith troposphere models can be introduced. Thus, the model strength can be improved, which is also called the RZTD-constrained RTK model. In this contribution, we first analyze the factors affecting the precision of BDS medium-long baseline RTK; thereafter, 15 baselines ranging from 38 km to 167 km in different troposphere conditions are processed to assess the performance of RZTD-constrained RTK. Results show that the troposphere parameter is difficult to distinguish from the height component, even with long time filtering for BDS-only RTK. Due to the lack of variation in geometry for the BDS geostationary Earth orbit satellite, the long convergence time of ambiguity parameters may reduce the height precision of GPS/BDS-combined RTK in the initial period. When the RZTD-constrained model was used in BDS and GPS/BDS-combined situations compared with the traditional RTK, the standard deviation of the height component for the fixed solution was reduced by 52.4% and 34.0%, respectively. PMID:29661999
Rivera-Rivera, Carlos J.; Montoya-Burgos, Juan I.
2016-01-01
Phylogenetic inference artifacts can occur when sequence evolution deviates from assumptions made by the models used to analyze them. The combination of strong model assumption violations and highly heterogeneous lineage evolutionary rates can become problematic in phylogenetic inference, and lead to the well-described long-branch attraction (LBA) artifact. Here, we define an objective criterion for assessing lineage evolutionary rate heterogeneity among predefined lineages: the result of a likelihood ratio test between a model in which the lineages evolve at the same rate (homogeneous model) and a model in which different lineage rates are allowed (heterogeneous model). We implement this criterion in the algorithm Locus Specific Sequence Subsampling (LS³), aimed at reducing the effects of LBA in multi-gene datasets. For each gene, LS³ sequentially removes the fastest-evolving taxon of the ingroup and tests for lineage rate homogeneity until all lineages have uniform evolutionary rates. The sequences excluded from the homogeneously evolving taxon subset are flagged as potentially problematic. The software implementation provides the user with the possibility to remove the flagged sequences for generating a new concatenated alignment. We tested LS³ with simulations and two real datasets containing LBA artifacts: a nucleotide dataset regarding the position of Glires within mammals and an amino-acid dataset concerning the position of nematodes within bilaterians. The initially incorrect phylogenies were corrected in all cases upon removing data flagged by LS³. PMID:26912812
Technology at the zoo: the influence of a touchscreen computer on orangutans and zoo visitors.
Perdue, Bonnie M; Clay, Andrea W; Gaalema, Diann E; Maple, Terry L; Stoinski, Tara S
2012-01-01
A computer-controlled touchscreen apparatus (hereafter referred to as "touchscreen") in the orangutan exhibit at Zoo Atlanta provides enrichment to the animals and allows cognitive research to take place on exhibit. This study investigated the impact of the touchscreen on orangutan behavior and visibility, as well as its impact on zoo visitors. Despite previous research suggesting that providing a single computer system may negatively affect orangutan behavior, there was not a significant increase in aggression, stereotypic, or distress-related behaviors following the activation of the on-exhibit touchscreen. We also investigated the possibility that zoo visitors may be negatively affected by technology because it deviates from naturalism. However, we did not find a change in stay time or overall experience rating when the computer was turned on. This research was the first to assess visitor attitudes toward technology at the zoo, and we found that visitors report highly positive attitudes about technology for both animals and visitors. If subjects visited the exhibit when the computer was turned on, they more strongly agreed that orangutans benefit from interacting with computerized enrichment. This study is the first investigation of an on-exhibit touchscreen in group-housed apes; our findings of no negative effects on the animals or zoo visitors and positive attitudes toward technology suggest a significant value of this practice. © 2011 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Asgari, Jamal; Mohammadloo, Tannaz H.; Amiri-Simkooei, Ali Reza
2015-09-01
GNSS kinematic techniques are capable of providing precise coordinates in extremely short observation time-span. These methods usually determine the coordinates of an unknown station with respect to a reference one. To enhance the precision, accuracy, reliability and integrity of the estimated unknown parameters, GNSS kinematic equations are to be augmented by possible constraints. Such constraints could be derived from the geometric relation of the receiver positions in motion. This contribution presents the formulation of the constrained kinematic global navigation satellite systems positioning. Constraints effectively restrict the definition domain of the unknown parameters from the three-dimensional space to a subspace defined by the equation of motion. To test the concept of the constrained kinematic positioning method, the equation of a circle is employed as a constraint. A device capable of moving on a circle was made and the observations from 11 positions on the circle were analyzed. Relative positioning was conducted by considering the center of the circle as the reference station. The equation of the receiver's motion was rewritten in the ECEF coordinates system. A special attention is drawn onto how a constraint is applied to kinematic positioning. Implementing the constraint in the positioning process provides much more precise results compared to the unconstrained case. This has been verified based on the results obtained from the covariance matrix of the estimated parameters and the empirical results using kinematic positioning samples as well. The theoretical standard deviations of the horizontal components are reduced by a factor ranging from 1.24 to 2.64. The improvement on the empirical standard deviation of the horizontal components ranges from 1.08 to 2.2.
Effects of climate change and variability on population dynamics in a long-lived shorebird.
van de Pol, Martijn; Vindenes, Yngvild; Saether, Bernt-Erik; Engen, Steinar; Ens, Bruno J; Oosterbeek, Kees; Tinbergen, Joost M
2010-04-01
Climate change affects both the mean and variability of climatic variables, but their relative impact on the dynamics of populations is still largely unexplored. Based on a long-term study of the demography of a declining Eurasian Oystercatcher (Haematopus ostralegus) population, we quantify the effect of changes in mean and variance of winter temperature on different vital rates across the life cycle. Subsequently, we quantify, using stochastic stage-structured models, how changes in the mean and variance of this environmental variable affect important characteristics of the future population dynamics, such as the time to extinction. Local mean winter temperature is predicted to strongly increase, and we show that this is likely to increase the population's persistence time via its positive effects on adult survival that outweigh the negative effects that higher temperatures have on fecundity. Interannual variation in winter temperature is predicted to decrease, which is also likely to increase persistence time via its positive effects on adult survival that outweigh the negative effects that lower temperature variability has on fecundity. Overall, a 0.1 degrees C change in mean temperature is predicted to alter median time to extinction by 1.5 times as many years as would a 0.1 degrees C change in the standard deviation in temperature, suggesting that the dynamics of oystercatchers are more sensitive to changes in the mean than in the interannual variability of this climatic variable. Moreover, as climate models predict larger changes in the mean than in the standard deviation of local winter temperature, the effects of future climatic variability on this population's time to extinction are expected to be overwhelmed by the effects of changes in climatic means. We discuss the mechanisms by which climatic variability can either increase or decrease population viability and how this might depend both on species' life histories and on the vital rates affected. This study illustrates that, for making reliable inferences about population consequences in species in which life history changes with age or stage, it is crucial to investigate the impact of climate change on vital rates across the entire life cycle. Disturbingly, such data are unavailable for most species of conservation concern.
Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner
2011-10-01
This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were within the safety margins recommended by the planning software. © 2011 John Wiley & Sons A/S.
Describing temporal variation in reticuloruminal pH using continuous monitoring data.
Denwood, M J; Kleen, J L; Jensen, D B; Jonsson, N N
2018-01-01
Reticuloruminal pH has been linked to subclinical disease in dairy cattle, leading to considerable interest in identifying pH observations below a given threshold. The relatively recent availability of continuously monitored data from pH boluses gives new opportunities for characterizing the normal patterns of pH over time and distinguishing these from abnormal patterns using more sensitive and specific methods than simple thresholds. We fitted a series of statistical models to continuously monitored data from 93 animals on 13 farms to characterize normal variation within and between animals. We used a subset of the data to relate deviations from the normal pattern to the productivity of 24 dairy cows from a single herd. Our findings show substantial variation in pH characteristics between animals, although animals within the same farm tended to show more consistent patterns. There was strong evidence for a predictable diurnal variation in all animals, and up to 70% of the observed variation in pH could be explained using a simple statistical model. For the 24 animals with available production information, there was also a strong association between productivity (as measured by both milk yield and dry matter intake) and deviations from the expected diurnal pattern of pH 2 d before the productivity observation. In contrast, there was no association between productivity and the occurrence of observations below a threshold pH. We conclude that statistical models can be used to account for a substantial proportion of the observed variability in pH and that future work with continuously monitored pH data should focus on deviations from a predictable pattern rather than the frequency of observations below an arbitrary pH threshold. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pressure fluctuation generated by the interaction of blade and tongue
NASA Astrophysics Data System (ADS)
Zheng, Lulu; Dou, Hua-Shu; Chen, Xiaoping; Zhu, Zuchao; Cui, Baoling
2018-02-01
Pressure fluctuation around the tongue has large effect on the stable operation of a centrifugal pump. In this paper, the Reynolds averaged Navier-Stokes equations (RANS) and the RNG k-epsilon turbulence model is employed to simulate the flow in a pump. The flow field in the centrifugal pump is computed for a range of flow rate. The simulation results have been compared with the experimental data and good agreement has been achieved. In order to study the interaction of the tongue with the impeller, fifteen monitor probes are evenly distributed circumferentially at three radii around the tongue. Pressure distribution is investigated at various blade positions while the blade approaches to and leaves the tongue region. Results show that pressure signal fluctuates largely around the tongue, and it is more intense near the tongue surface. At design condition, standard deviation of pressure fluctuation is the minimum. At large flow rate, the increased low pressure region at the blade trailing edge results in the increases of pressure fluctuation amplitude and pressure spectra at the monitor probes. Minimum pressure is obtained when the blade is facing to the tongue. It is found that the amplitude of pressure fluctuation strongly depends on the blade positions at large flow rate, and pressure fluctuation is caused by the relative movement between blades and tongue. At small flow rate, the rule of pressure fluctuation is mainly depending on the structure of vortex flow at blade passage exit besides the influence from the relative position between the blade and the tongue.
Konishi, Eiji; Konishi, Mayu
2011-01-01
Japanese encephalitis virus (JEV) and the four dengue viruses (DENV1-4) are co-distributed in Southeast and South Asia. Since JEV is antigenically cross-reactive with DENV1-4, the differentiation between these viruses using antibody assays may be difficult. Herein, we describe the development of an epitope-blocking enzyme-linked immunosorbent assay (ELISA) using a monoclonal antibody specific for the nonstructural protein 1 (NS1) of JEV (JEV-NS1) to differentiate antibodies against JEV from those against DENV1-4. Hyperimmune mouse sera against JEV-NS1 showed >60% inhibition, whereas those against NS1 of DENV1-4 showed <30% inhibition. The present assay could therefore detect antibodies specific for JEV. For testing of human sera, a temporary cutoff value (30.8%) was calculated the average and standard deviation obtained for sera of control humans negative for JEV antibodies. Human sera positive for antibodies to any of DENV1-4 NS1 but negative for antibodies to JEV-NS1 showed a lower percentage inhibition than the cutoff value. On the other hand, sera with JEV-NS1 antibody levels of ≥0.400, as determined by the conventional ELISA (medially/strongly positive for JEV-NS1 antibodies), showed percentage inhibition greater than the cutoff. Although this blocking ELISA afforded false-negative results for most sera that were weakly positive for JEV-NS1 antibodies, it may be useful for investigating the seroepidemiology of JEV antibodies in dengue-endemic areas.
Mori, S
2014-05-01
To ensure accuracy in respiratory-gating treatment, X-ray fluoroscopic imaging is used to detect tumour position in real time. Detection accuracy is strongly dependent on image quality, particularly positional differences between the patient and treatment couch. We developed a new algorithm to improve the quality of images obtained in X-ray fluoroscopic imaging and report the preliminary results. Two oblique X-ray fluoroscopic images were acquired using a dynamic flat panel detector (DFPD) for two patients with lung cancer. The weighting factor was applied to the DFPD image in respective columns, because most anatomical structures, as well as the treatment couch and port cover edge, were aligned in the superior-inferior direction when the patient lay on the treatment couch. The weighting factors for the respective columns were varied until the standard deviation of the pixel values within the image region was minimized. Once the weighting factors were calculated, the quality of the DFPD image was improved by applying the factors to multiframe images. Applying the image-processing algorithm produced substantial improvement in the quality of images, and the image contrast was increased. The treatment couch and irradiation port edge, which were not related to a patient's position, were removed. The average image-processing time was 1.1 ms, showing that this fast image processing can be applied to real-time tumour-tracking systems. These findings indicate that this image-processing algorithm improves the image quality in patients with lung cancer and successfully removes objects not related to the patient. Our image-processing algorithm might be useful in improving gated-treatment accuracy.
Behavioral Economics Applied to Energy Demand Analysis: A Foundation
2014-01-01
Neoclassical economics has shaped our understanding of human behavior for several decades. While still an important starting point for economic studies, neoclassical frameworks have generally imposed strong assumptions, for example regarding utility maximization, information, and foresight, while treating consumer preferences as given or external to the framework. In real life, however, such strong assumptions tend to be less than fully valid. Behavioral economics refers to the study and formalizing of theories regarding deviations from traditionally-modeled economic decision-making in the behavior of individuals. The U.S. Energy Information Administration (EIA) has an interest in behavioral economics as one influence on energy demand.
Electrical and Thermal Transport in Inhomogeneous Luttinger Liquids
DeGottardi, Wade; Matveev, K. A.
2015-06-12
In this paper, we study the transport properties of long quantum wires by generalizing the Luttinger liquid approach to allow for the finite lifetime of the bosonic excitations. Our theory accounts for long-range disorder and strong electron interactions, both of which are common features of experiments with quantum wires. We obtain the electrical and thermal resistances and thermoelectric properties of such quantum wires and find a strong deviation from perfect conductance quantization. Finally, we cast our results in terms of the thermal conductivity and bulk viscosity of the electron liquid and give the temperature scale above which the transport canmore » be described by classical hydrodynamics.« less
ω→π0γ* and ϕ→π0γ* transition form factors in dispersion theory
NASA Astrophysics Data System (ADS)
Schneider, Sebastian P.; Kubis, Bastian; Niecknig, Franz
2012-09-01
We calculate the ω→π0γ* and ϕ→π0γ* electromagnetic transition form factors based on dispersion theory, relying solely on a previous dispersive analysis of the corresponding three-pion decays and the pion vector form factor. We compare our findings to recent measurements of the ω→π0μ+μ- decay spectrum by the NA60 collaboration, and strongly encourage experimental investigation of the Okubo-Zweig-Iizuka forbidden ϕ→π0ℓ+ℓ- decays in order to understand the strong deviations from vector-meson dominance found in these transition form factors.
Who pays for public employee health costs?
Clemens, Jeffrey; Cutler, David M
2014-12-01
We analyze the incidence of public-employee health benefits. Because these benefits are negotiated through the political process, relevant labor market institutions deviate significantly from the competitive, private-sector benchmark. Empirically, we find that roughly 15 percent of the cost of recent benefit growth was passed onto school district employees through reductions in wages and salaries. Strong teachers' unions were associated with relatively strong linkages between benefit growth and growth in total compensation. Our analysis is consistent with the view that the costs of public workers' benefits are difficult to monitor, contributing to benefit oriented, and often under-funded, compensation schemes. Copyright © 2014 Elsevier B.V. All rights reserved.
Heightened odds of large earthquakes near Istanbul: an interaction-based probability calculation
Parsons, T.; Toda, S.; Stein, R.S.; Barka, A.; Dieterich, J.H.
2000-01-01
We calculate the probability of strong shaking in Istanbul, an urban center of 10 million people, from the description of earthquakes on the North Anatolian fault system in the Marmara Sea during the past 500 years and test the resulting catalog against the frequency of damage in Istanbul during the preceding millennium, departing from current practice, we include the time-dependent effect of stress transferred by the 1999 moment magnitude M = 7.4 Izmit earthquake to faults nearer to Istanbul. We find a 62 ± 15% probability (one standard deviation) of strong shaking during the next 30 years and 32 ± 12% during the next decade.
Sterling, Robie; Miranda, J Jaime; Gilman, Robert H; Cabrera, Lilia; Sterling, Charles R; Bern, Caryn; Checkley, William
2014-01-01
While childhood malnutrition is associated with increased morbidity and mortality, less well understood is how early childhood growth influences height and body composition later in life. We revisited 152 Peruvian children who participated in a birth cohort study between 1995 and 1998, and obtained anthropometric and bioimpedance measurements 11 to 14 years later. We used multivariable regression models to study the effects of childhood anthropometric indices on height and body composition in early adolescence. Each standard deviation decrease in length-for-age at birth was associated with a decrease in adolescent height-for-age of 0.7 SD in both boys and girls (all p<0.001) and 9.7 greater odds of stunting (95% CI 3.3 to 28.6). Each SD decrease in length-for-age in the first 30 months of life was associated with a decrease in adolescent height-for-age of 0.4 in boys and 0.6 standard deviation in girls (all p<0.001) and with 5.8 greater odds of stunting (95% CI 2.6 to 13.5). The effect of weight gain during early childhood on weight in early adolescence was more complex to understand. Weight-for-length at birth and rate of change in weight-for-length in early childhood were positively associated with age- and sex-adjusted body mass index and a greater risk of being overweight in early adolescence. Linear growth retardation in early childhood is a strong determinant of adolescent stature, indicating that, in developing countries, growth failure in height during early childhood persists through early adolescence. Interventions addressing linear growth retardation in childhood are likely to improve adolescent stature and related-health outcomes in adulthood. PMID:22552904
Sterling, Robie; Miranda, J Jaime; Gilman, Robert H; Cabrera, Lilia; Sterling, Charles R; Bern, Caryn; Checkley, William
2012-07-01
While childhood malnutrition is associated with increased morbidity and mortality, less well understood is how early childhood growth influences height and body composition later in life. We revisited 152 Peruvian children who participated in a birth cohort study between 1995 and 1998, and obtained anthropometric and bioimpedance measurements 11-14 years later. We used multivariable regression models to study the effects of childhood anthropometric indices on height and body composition in early adolescence. Each standard deviation decrease in length-for-age at birth was associated with a decrease in adolescent height-for-age of 0.7 SD in both boys and girls (all P < 0.001) and 9.7 greater odds of stunting (95% CI 3.3-28.6). Each SD decrease in length-for-age in the first 30 months of life was associated with a decrease in adolescent height-for-age of 0.4 in boys and 0.6 standard deviation in girls (all P < 0.001) and with 5.8 greater odds of stunting (95% CI 2.6-13.5). The effect of weight gain during early childhood on weight in early adolescence was more complex to understand. Weight-for-length at birth and rate of change in weight-for-length in early childhood were positively associated with age- and sex-adjusted body mass index and a greater risk of being overweight in early adolescence. Linear growth retardation in early childhood is a strong determinant of adolescent stature, indicating that, in developing countries, growth failure in height during early childhood persists through early adolescence. Interventions addressing linear growth retardation in childhood are likely to improve adolescent stature and related-health outcomes in adulthood. Copyright © 2012 Wiley Periodicals, Inc.
Meyers, Nicholaus; Sukopp, Matthias; Jäger, Rudolf; Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz
2017-01-01
Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies.
Steiner, Malte; Matthys, Romano; Lapatki, Bernd; Ignatius, Anita; Claes, Lutz
2017-01-01
Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies. PMID:28453556
The Astrometric Recognition of the Solar Clementine Gnomon (1702)
NASA Astrophysics Data System (ADS)
Sigismondi, Costantino
The Clementine gnomon has been built in 1702 to measure the Earth's obliquity variation. For this reason the pinhole was located in the walls of Diocletian's times (305 a. D.) in order to remain stable along the centuries, but its original form and position have been modified. We used an astrometric method to recover the original position of the pinhole: reshaping the pinhole to a circle of 1.5 cm of diameter, the positions of the Northern and Southern limbs have been compared with the ephemerides. A sistematic shift of 4.5 mm Southward of the whole solar image shows that the original pinhole was 4.5 mm North of the actual position, as the images in the Bianchini's book (1703) suggest. The oval shape of the actual pinhole is also wrong. Using a circle the larger solar spots are clearly visible. Some reference stars of the catalogue of Philippe de la Hire (1702), used originally for measuring the ecliptic latitude of the Sun, are written next to the meridian line, but after the last restauration (2000), four of them are wrongly located. Finally the deviation from the true North, of the meridian line's azimuth confirms the value recovered in 1750. This, with the local deviations of a true line, will remain as systematic error, like for all these historical instruments.
GNSS Antenna Caused Near-Field Interference Effect in Precise Point Positioning Results
NASA Astrophysics Data System (ADS)
Dawidowicz, Karol; Baryła, Radosław
2017-06-01
Results of long-term static GNSS observation processing adjustment prove that the often assumed "averaging multipath effect due to extended observation periods" does not actually apply. It is instead visible a bias that falsifies the coordinate estimation. The comparisons between the height difference measured with a geometrical precise leveling and the height difference provided by GNSS clearly verify the impact of the near-field multipath effect. The aim of this paper is analysis the near-field interference effect with respect to the coordinate domain. We demonstrate that the way of antennas mounting during observation campaign (distance from nearest antennas) can cause visible changes in pseudo-kinematic precise point positioning results. GNSS measured height differences comparison revealed that bias of up to 3 mm can be noticed in Up component when some object (additional GNSS antenna) was placed in radiating near-field region of measuring antenna. Additionally, for both processing scenario (GPS and GPS/GLONASS) the scattering of results clearly increased when additional antenna crosses radiating near-field region of measuring antenna. It is especially true for big choke ring antennas. In short session (15, 30 min.) the standard deviation was about twice bigger in comparison to scenario without additional antenna. When we used typical surveying antennas (short near-field region radius) the effect is almost invisible. In this case it can be observed the standard deviation increase of about 20%. On the other hand we found that surveying antennas are generally characterized by lower accuracy than choke ring antennas. The standard deviation obtained on point with this type of antenna was bigger in all processing scenarios (in comparison to standard deviation obtained on point with choke ring antenna).
Mazzoni, Simona; Marchetti, Claudio; Sgarzani, Rossella; Cipriani, Riccardo; Scotti, Roberto; Ciocca, Leonardo
2013-06-01
The aim of the present study was to evaluate the accuracy of prosthetically guided maxillofacial surgery in reconstructing the mandible with a free vascularized flap using custom-made bone plates and a surgical guide to cut the mandible and fibula. The surgical protocol was applied in a study group of seven consecutive mandibular-reconstructed patients who were compared with a control group treated using the standard preplating technique on stereolithographic models (indirect computer-aided design/computer-aided manufacturing method). The precision of both surgical techniques (prosthetically guided maxillofacial surgery and indirect computer-aided design/computer-aided manufacturing procedure) was evaluated by comparing preoperative and postoperative computed tomographic data and assessment of specific landmarks. With regard to midline deviation, no significant difference was documented between the test and control groups. With regard to mandibular angle shift, only one left angle shift on the lateral plane showed a statistically significant difference between the groups. With regard to angular deviation of the body axis, the data showed a significant difference in the arch deviation. All patients in the control group registered greater than 8 degrees of deviation, determining a facial contracture of the external profile at the lower margin of the mandible. With regard to condylar position, the postoperative condylar position was better in the test group than in the control group, although no significant difference was detected. The new protocol for mandibular reconstruction using computer-aided design/computer-aided manufacturing prosthetically guided maxillofacial surgery to construct custom-made guides and plates may represent a viable method of reproducing the patient's anatomical contour, giving the surgeon better procedural control and reducing procedure time. Therapeutic, III.
Evaluating metrics of local topographic position for multiscale geomorphometric analysis
NASA Astrophysics Data System (ADS)
Newman, D. R.; Lindsay, J. B.; Cockburn, J. M. H.
2018-07-01
The field of geomorphometry has increasingly moved towards the use of multiscale analytical techniques, due to the availability of fine-resolution digital elevation models (DEMs) and the inherent scale-dependency of many DEM-derived attributes such as local topographic position (LTP). LTP is useful for landform and soils mapping and numerous other environmental applications. Multiple LTP metrics have been proposed and applied in the literature; however, elevation percentile (EP) is notable for its robustness to elevation error and applicability to non-Gaussian local elevation distributions, both of which are common characteristics of DEM data sets. Multiscale LTP analysis involves the estimation of spatial patterns using a range of neighborhood sizes, traditionally achieved by applying spatial filtering techniques with varying kernel sizes. While EP can be demonstrated to provide accurate estimates of LTP, the computationally intensive method of its calculation makes it unsuited to multiscale LTP analysis, particularly at large neighborhood sizes or with fine-resolution DEMs. This research assessed the suitability of three LTP metrics for multiscale terrain characterization by quantifying their computational efficiency and by comparing their ability to approximate EP spatial patterns under varying topographic conditions. The tested LTP metrics included: deviation from mean elevation (DEV), percent elevation range (PER), and the novel relative topographic position (RTP) index. The results demonstrated that DEV, calculated using the integral image technique, offers fast and scale-invariant computation. DEV spatial patterns were strongly correlated with EP (r2 range of 0.699 to 0.967) under all tested topographic conditions. RTP was also a strong predictor of EP (r2 range of 0.594 to 0.917). PER was the weakest predictor of EP (r2 range of 0.031 to 0.801) without offering a substantial improvement in computational efficiency over RTP. PER was therefore determined to be unsuitable for most multiscale applications. It was concluded that the scale-invariant property offered by the integral image used by the DEV method counters the minor losses in robustness compared to EP, making DEV the optimal LTP metric for multiscale applications.
Methods for Linking Item Parameters.
1981-08-01
within and across data sets; all proportion-correct distributions were quite platykurtic . Biserial item-total correlations had relatively consistent...would produce a distribution of a parameters which had a larger mean and standard deviation, was more positively skewed, and was somewhat more platykurtic
Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Novotny, J., E-mail: josef.novotnyml@homolka.cz; Department of Medical Physics, Na Homolce Hospital, Prague 150 30; Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University in Prague, Prague 120 00
2014-03-15
Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, amore » service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.« less
SU-E-J-22: A Feasibility Study On KV-Based Whole Breast Radiation Patient Setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Q; Zhang, M; Yue, N
Purpose: In room kilovoltage x-ray (kV) imaging provides higher contrast than Megavoltage (MV) imaging with faster acquisition time compared with on-board cone-beam computed tomography (CBCT), thus improving patient setup accuracy and efficiency. In this study we evaluated the clinical feasibility of utilizing kV imaging for whole breast radiation patient setup. Methods: For six breast cancer patients with whole breast treatment plans using two opposed tangential fields, MV-based patient setup was conducted by aligning patient markers with in room lasers and MV portal images. Beam-eye viewed kV images were acquired using Varian OBI system after the set up process. In housemore » software was developed to transfer MLC blocks information overlaying onto kV images to demonstrate the field shape for verification. KV-based patient digital shift was derived by performing rigid registration between kV image and the digitally reconstructed radiography (DRR) to align the bony structure. This digital shift between kV-based and MV-based setup was defined as setup deviation. Results: Six sets of kV images were acquired for breast patients. The mean setup deviation was 2.3mm, 2.2mm and 1.8mm for anterior-posterior, superior-inferior and left-right direction respectively. The average setup deviation magnitude was 4.3±1.7mm for six patients. Patient with large breast had a larger setup deviation (4.4–6.2mm). There was no strong correlation between MV-based shift and setup deviation. Conclusion: A preliminary clinical workflow for kV-based whole breast radiation setup was established and tested. We observed setup deviation of the magnitude below than 5mm. With the benefit of providing higher contrast and MLC block overlaid on the images for treatment field verification, it is feasible to use kV imaging for breast patient setup.« less
Vasak, Christoph; Strbac, Georg D; Huber, Christian D; Lettner, Stefan; Gahleitner, André; Zechner, Werner
2015-02-01
The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method. Overall, 60 implants were placed in 10 artificial edentulous mandibles according to the NobelGuide™ protocol. For merging the pre- and postoperative DICOM data sets, three different fusion methods (Triple Scan Technique, NobelGuide™ Validation software, and AMIRA® software [VSG - Visualization Sciences Group, Burlington, MA, USA] as reference) were applied. Discrepancies between the virtual and the actual implant positions were measured. The mean deviations measured with AMIRA® were 0.49 mm (implant shoulder), 0.69 mm (implant apex), and 1.98°mm (implant axis). The Triple Scan Technique as well as the NobelGuide™ Validation software revealed similar deviations compared with the reference method. A significant correlation between angular and apical deviations was seen (r = 0.53; p < .001). A greater implant diameter was associated with greater deviations (p = .03). The Triple Scan Technique as a system-independent validation procedure as well as the NobelGuide™ Validation software are in accordance with the AMIRA® software. The NobelGuide™ system showed similar or less spatial and angular deviations compared with others. © 2013 Wiley Periodicals, Inc.
Navigated total knee arthroplasty: is it error-free?
Chua, Kerk Hsiang Zackary; Chen, Yongsheng; Lingaraj, Krishna
2014-03-01
The aim of this study was to determine whether errors do occur in navigated total knee arthroplasty (TKAs) and to study whether errors in bone resection or implantation contribute to these errors. A series of 20 TKAs was studied using computer navigation. The coronal and sagittal alignments of the femoral and tibial cutting guides, the coronal and sagittal alignments of the final tibial implant and the coronal alignment of the final femoral implant were compared with that of the respective bone resections. To determine the post-implantation mechanical alignment of the limb, the coronal alignment of the femoral and tibial implants was combined. The median deviation between the femoral cutting guide and bone resection was 0° (range -0.5° to +0.5°) in the coronal plane and 1.0° (range -2.0° to +1.0°) in the sagittal plane. The median deviation between the tibial cutting guide and bone resection was 0.5° (range -1.0° to +1.5°) in the coronal plane and 1.0° (range -1.0° to +3.5°) in the sagittal plane. The median deviation between the femoral bone resection and the final implant was 0.25° (range -2.0° to 3.0°) in the coronal plane. The median deviation between the tibial bone resection and the final implant was 0.75° (range -3.0° to +1.5°) in the coronal plane and 1.75° (range -4.0° to +2.0°) in the sagittal plane. The median post-implantation mechanical alignment of the limb was 0.25° (range -3.0° to +2.0°). When navigation is used only to guide the positioning of the cutting jig, errors may arise in the manual, non-navigated steps of the procedure. Our study showed increased cutting errors in the sagittal plane for both the femur and the tibia, and following implantation, the greatest error was seen in the sagittal alignment of the tibial component. Computer navigation should be used not only to guide the positioning of the cutting jig, but also to check the bone resection and implant position during TKA. IV.
Perceived Neighborhood Social Cohesion and Myocardial Infarction
Kim, Eric S.; Hawes, Armani M.; Smith, Jacqui
2015-01-01
Background The main strategy for alleviating heart disease has been to target individuals and encourage them to change their health behaviors. Though important, emphasis on individuals has diverted focus and responsibility away from neighborhood characteristics, which also strongly influence people’s behaviors. Although a growing body of research has repeatedly demonstrated strong associations between neighborhood characteristics and cardiovascular health, it has typically focused on negative neighborhood characteristics. Only a few studies have examined the potential health enhancing effects of positive neighborhood characteristics, such as perceived neighborhood social cohesion. Methods Using multiple logistic regression models, we tested whether higher perceived neighborhood social cohesion was associated with lower incidence of myocardial infarction. Prospective data from the Health and Retirement Study—a nationally representative panel study of American adults over the age of 50—were used to analyze 5,276 participants with no history of heart disease. Respondents were tracked for four years and analyses adjusted for relevant sociodemographic, behavioral, biological, and psychosocial factors. Results In a model that adjusted for age, gender, race, marital status, education, and total wealth, each standard deviation increase in perceived neighborhood social cohesion was associated with a 22% reduced odds of myocardial infarction (OR = 0.78, 95% CI, 0.63–0.94. The association between perceived neighborhood social cohesion and myocardial infarction remained even after adjusting for behavioral, biological, and psychosocial covariates. Conclusions Higher perceived neighborhood social cohesion may have a protective effect against myocardial infarction. PMID:25135074
Forest wildfire increases soil microbial biomass C:N:P stoichiometry in long-term effects
NASA Astrophysics Data System (ADS)
Zhou, Xuan
2017-04-01
Boreal forest fire strongly influences carbon (C) stock in permafrost soil by thawing permafrost table which accelerated microbe decomposition process. We studied soil microbial biomass stoichiometry in a gradient of four (3 yr, 25 yr, 46 yr and more than 100 yr) ages since fire in Canada boreal forest. Soil microbial biomass (MB) in long-term after fire is significantly higher than in short-term. MB C and nitrogen (N) were mainly dominated by corresponding soil element concentration and inorganic P, while MB phosphorus (P) changes were fully explained by soil N. Fire ages and soil temperature positively increased MB N and P, indicating the negative impact by fire. Microbial C:N:P gradually increased with fire ages from 15:2:1 to 76:6:1 and then drop down to 17:2:1 in the oldest fire ages. The degree of homeostasis of microbial C, N and P are close to 1 indicates non-homoeostasis within microbial elements, while it of C:N:P is close to 8 shows a strong homeostasis within element ratios and proved microbial stoichiometric ratio is not driven by soil element ratios. In conclusion, i) microbial biomass elements highly depends on soil nutrient supply rather than fire ages; ii) wildfire decreased microbial stoichiometry immediate after fire but increased with years after fire (YF) which at least 3 times higher than > 100 fire ages; iii) microbial biomass C, N and P deviated from strict homeostasis but C:N:P ratio reflects stronger homeostasis.
Characterization of magnetic flux density in passive sources used in magnetic stimulation
NASA Astrophysics Data System (ADS)
Torres, J.; Hincapie, E.; Gilart, F.
2018-03-01
The spatial distribution of the magnetic flux density (B) was determined for the passive sources of magnetic field most used in magnetic stimulation of biological systems, toroidal dipole magnets and cylindrical dipole magnets, in order to find the spatial characteristics of the magnetic field within the volumes of interest for the treatment of biological systems. The perpendicular and parallel components of B regarding the polar surface of the magnets were measured, for which a FW Bell 5180 digital teslameter was used with longitudinal and transverse probes and a two-dimensional positioning system with millimeter scale. It was found that the magnets of this type, which are the most used, present a strong variation of the magnitude and direction of the magnetic flux density for spaces specified in millimeters, reason why the homogeneity of the magnetic field in the regions of interest was found to be relatively low, which makes them elements with a strong applicability for the stimulation of biological systems in which magnetic field gradients up to mT/mm are required in the case of cylindrical magnets, and up to tens of mT/mm in the case of toroidal magnets. Finally, it is concluded that a high percentage of experiments reported in the literature on magnetic treatment of biological systems may be presenting values of B in their doses with deviations of more than 100% of the real value, which raises an incongruence in the cause-effect proposed relation.
SU-F-T-177: Impacts of Gantry Angle Dependent Scanning Beam Properties for Proton Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y; Clasie, B; Lu, H
Purpose: In pencil beam scanning (PBS), the delivered spot MU, position and size are slightly different at different gantry angles. We investigated the level of delivery uncertainty at different gantry angles through a log file analysis. Methods: 34 PBS fields covering full 360 degrees gantry angle spread were collected retrospectively from 28 patients treated at our institution. All fields were delivered at zero gantry angle and the prescribed gantry angle, and measured at isocenter with the MatriXX 2D array detector at the prescribed gantry angle. The machine log files were analyzed to extract the delivered MU per spot and themore » beam position from the strip ionization chambers in the treatment nozzle. The beam size was separately measured as a function of gantry angle and beam energy. Using this information, the dose was calculated in a water phantom at both gantry angles and compared to the measurement using the 3D γ-index at 2mm/2%. Results: The spot-by-spot difference between the beam position in the log files from the delivery at the two gantry angles has a mean of 0.3 and 0.4 mm and a standard deviation of 0.6 and 0.7 mm for × and y directions, respectively. Similarly, the spot-by-spot difference between the MU in the log files from the delivery at the two gantry angles has a mean 0.01% and a standard deviation of 0.7%. These small deviations lead to an excellent agreement in dose calculations with an average γ pass rate for all fields being approximately 99.7%. When each calculation is compared to the measurement, a high correlation in γ was also found. Conclusion: Using machine logs files, we verified that PBS beam delivery at different gantry angles are sufficiently small and the planned spot position and MU. This study brings us one step closer to simplifying our patient-specific QA.« less
Testing the cosmological principle of isotropy: local power-spectrum estimates of the WMAP data
NASA Astrophysics Data System (ADS)
Hansen, F. K.; Banday, A. J.; Górski, K. M.
2004-11-01
We apply the Gabor transform methodology proposed by Hansen et al. to the WMAP data in order to test the statistical properties of the cosmic microwave background (CMB) fluctuation field and specifically to evaluate the fundamental assumption of cosmological isotropy. In particular, we apply the transform with several apodization scales, thus allowing the determination of the positional dependence of the angular power spectrum with either high spatial localization or high angular resolution (i.e. narrow bins in multipole space). Practically, this implies that we estimate the angular power spectrum locally in discs of various sizes positioned in different directions: small discs allow the greatest sensitivity to positional dependence, whereas larger discs allow greater sensitivity to variations over different angular scales. In addition, we determine whether the spatial position of a few outliers in the angular power spectrum could suggest the presence of residual foregrounds or systematic effects. For multipoles close to the first peak, the most deviant local estimates from the best-fitting WMAP model are associated with a few particular areas close to the Galactic plane. Such deviations also include the `dent' in the spectrum just shortward of the first peak which was remarked upon by the WMAP team. Estimating the angular power spectrum excluding these areas gives a slightly higher first Doppler peak amplitude. Finally, we probe the isotropy of the largest angular scales by estimating the power spectrum on hemispheres and reconfirm strong indications of a north-south asymmetry previously reported by other authors. Indeed, there is a remarkable lack of power in a region associated with the North ecliptic Pole. With the greater fidelity in l-space allowed by this larger sky coverage, we find tentative evidence for residual foregrounds in the range l= 2-4, which could be associated with the low measured quadrupole amplitudes and other anomalies on these angular scales (e.g. planarity and alignment). However, over the range l= 5-40 the observed asymmetry is much harder to explain in terms of residual foregrounds and known systematic effects. By reorienting the coordinate axes, we partition the sky into different hemispheres and search for the reference frame which maximizes the asymmetric distribution of power. The North Pole for this coordinate frame is found to intersect the sphere at (80°, 57°) in Galactic colatitude and longitude over almost the entire multipole range l= 5-40. Furthermore, the strong negative outlier at l= 21 and the strong positive outlier at l= 39, as determined from the global power spectrum by the WMAP team, are found to be associated with the Northern and Southern hemispheres, respectively (in this frame of maximum asymmetry). Thus, these two outliers follow the general tendency of the multipoles l= 5-40 to be of systematically lower amplitude in the north and higher in the south. Such asymmetric distributions of power on the sky provide a serious test for the cosmological principle of isotropy.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... remain in the closed-to- navigation position for the duration of the 2011 Orange King Festival Bicycle... purpose of the running of the 2011 Orange King Festival Bike Race. This deviation is effective December 3...
NASA Astrophysics Data System (ADS)
Zhang, Wei; Huang, Wei; Gao, Yubo; Qi, Yafei; Hypervelocity Impact Research Center Team
2015-06-01
Laboratory-scaled oblique water entry experiments for the trajectory stability in the water column have been performed with four different nosed-projectiles at a range of velocities from 20m /s to 250 m /s . The slender projectiles are designed with flat, ogival, hemi-sperical, truncated-ogival noses to make comparisons on the trajectory deviation when they are launched at vertical and oblique impact angles (0°~25°). Two high-speed cameras that are positioned orthogonal to each other and normal to the column are employed to capture the entire process of projectiles' penetration. From the experimental results, the sequential images in two planes are presented to compare the trajectory deviation of different impact tests and the 3D trajectory models are extracted based on the location recorded by cameras. Considering the effect influenced by the impact velocities and noses of projectiles, it merited concluded that trajectory deviation is affected from most by impact angle, and least by impact velocities. Additionally, ogival projectiles tend to be more sensitive to oblique angle and experienced the largest attitude changing. National Natural Science Foundation of China (NO.: 11372088).
Ipsiversive ictal eye deviation in inferioposterior temporal lobe epilepsy-Two SEEG cases report.
Zhang, Wei; Liu, Xingzhou; Zuo, Lijun; Guo, Qiang; Chen, Qi; Wang, Yongjun
2017-02-21
Versive seizure characterized by conjugate eye movement during epileptic seizure has been considered commonly as one of the most valuable semiological signs for epilepsy localization, especially for frontal lobe epilepsy. However, the lateralizing and localizing significance of ictaleye deviation has been questioned by clinical observation of a series of focal epilepsy studies, including frontal, central, temporal, parietal and occipital epilepsy. Two epileptic cases characterized by ipsiversive eye deviation as initial clinical sign during the habitual epileptic seizures are presented in this paper. The localization of the epileptogenic zone of both of the cases has been confirmed as inferioposterior temporal region by the findings of ictalstereoelectroencephalography (SEEG) and a good result after epileptic surgery. Detailed analysis of the exact position of the key contacts of the SEEG electrodes identified the overlap between the location of the epileptogenic zone and human MT/MST complex, which play a crucial role in the control of smooth pursuit eye movement. Ipsiversive eye deviation could be the initial clinical sign of inferioposterior temporal lobe epilepsy and attribute to the involvement of human MT/MST complex, especially human MST whichwas located on the anterior/dorsal bank of the anterior occipital sulcus (AOS).
Mars Global Reference Atmospheric Model (Mars-GRAM) and Database for Mission Design
NASA Technical Reports Server (NTRS)
Justus, C. G.; Duvall, Aleta; Johnson, D. L.
2003-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model, while above 80 km it is based on Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter. Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science and Thermal Emission Spectrometer data. RS data from 2480 profiles were used, covering latitudes 75 deg S to 72 deg N, surface to approximately 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160 deg and 265-310 deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, RS density varied by about a factor of 2.5 over ranges of latitudes and Ls values observed. Evaluated at matching positions and times, these figures show average RSMars-GRAM density ratios were generally 1+/-)0.05, except at heights above approximately 25 km and latitudes above approximately 50 deg N. Average standard deviation of RSMars-GRAM density ratio was 6%. TES data were used covering surface to approximately 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). Depending on season, TES data covered latitudes 85 deg S to 85 deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (greater than 45 deg N), or at most altitudes in the southern hemisphere at Ls approximately 90 and 180 deg. Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approximately 2.5% for all data, or approximately 1-4%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about three times the standard deviation of TES data about the TES mean value at a given position and season.
Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects.
Su, Daniel; Greenberg, Andrew; Simonson, Joseph L; Teng, Christopher C; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2016-04-01
To investigate the efficacy of the Amsler grid test in detecting central visual field (VF) defects in glaucoma. Prospective, cross-sectional study. Patients with glaucoma with reliable Humphrey 10-2 Swedish Interactive Threshold Algorithm standard VF on the date of enrollment or within the previous 3 months. Amsler grid tests were performed for each eye and were considered "abnormal" if there was any perceived scotoma with missing or blurry grid lines within the central 10 degrees ("Amsler grid scotoma"). An abnormal 10-2 VF was defined as ≥3 adjacent points at P < 0.01 with at least 1 point at P < 0.005 in the same hemifield on the pattern deviation plot. Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area were calculated with the 10-2 VF as the clinical reference standard. Among eyes with an abnormal 10-2 VF, regression analyses were performed between the Amsler grid scotoma area and the 10-2 VF parameters (mean deviation [MD], scotoma extent [number of test points with P < 0.01 in total deviation map] and scotoma mean depth [mean sensitivity of test points with P < 0.01 in total deviation map]). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area. A total of 106 eyes (53 patients) were included (mean ± standard deviation age, 24-2 MD and 10-2 MD = 66±12 years, -9.61±8.64 decibels [dB] and -9.75±9.00 dB, respectively). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid test were 68%, 92%, 97%, and 46%, respectively. Sensitivity was 40% in eyes with 10-2 MD better than -6 dB, 58% in eyes with 10-2 MD between -12 and -6 dB, and 92% in eyes with 10-2 MD worse than -12 dB. The area under the receiver operating characteristic curve of the Amsler grid scotoma area was 0.810 (95% confidence interval, 0.723-0.880, P < 0.001). The Amsler grid scotoma area had the strongest relationship with 10-2 MD (quadratic R(2)=0.681), followed by 10-2 scotoma extent (quadratic R(2)=0.611) and 10-2 scotoma mean depth (quadratic R(2)=0.299) (all P < 0.001). The Amsler grid can be used to screen for moderate to severe central vision loss from glaucoma. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
[Cognitive errors in diagnostic decision making].
Gäbler, Martin
2017-10-01
Approximately 10-15% of our diagnostic decisions are faulty and may lead to unfavorable and dangerous outcomes, which could be avoided. These diagnostic errors are mainly caused by cognitive biases in the diagnostic reasoning process.Our medical diagnostic decision-making is based on intuitive "System 1" and analytical "System 2" diagnostic decision-making and can be deviated by unconscious cognitive biases.These deviations can be positively influenced on a systemic and an individual level. For the individual, metacognition (internal withdrawal from the decision-making process) and debiasing strategies, such as verification, falsification and rule out worst-case scenarios, can lead to improved diagnostic decisions making.
Long-term comparisons between two-way satellite and geodetic time transfer systems.
Plumb, John F; Larson, Kristine M
2005-11-01
Global Positioning System (GPS) observations recorded in the United States and Europe were used to evaluate time transfer capabilities of GETT (geodetic time transfer). Timing estimates were compared with two-way satellite time and frequency transfer (TWSTFT) systems. A comparison of calibrated links at the U.S. Naval Observatory, Washington, D.C., and Colorado Springs, CO, yielded agreement of 2.17 ns over 6 months with a standard deviation of 0.73 ns. An uncalibrated link between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt, Braunschweig, Germany, has a standard deviation of 0.79 ns over the same time period.
Temperature dependence of the LO phonon sidebands in free exciton emission of GaN
NASA Astrophysics Data System (ADS)
Xu, S. J.; Li, G. Q.; Xiong, S.-J.; Che, C. M.
2006-04-01
Temperature-dependent radiative recombination of free excitons involving one or two LO phonons in GaN is investigated in detail. It is found that both phonon sidebands possess asymmetric lineshapes and their energy spacings from the zero-phonon line strongly deviate from the characteristic energy of LO phonons as the temperature increases. Furthermore, the deviation rates of one- and two-phonon sidebands are significantly different. Segall-Mahan [Phys. Rev. 171, 935 (1968)] theory, taking the exciton-photon and exciton-phonon interactions into account, is employed to calculate the sidebands of one or two LO phonons for free excitons in a wide temperature range. Excellent agreement between the theory and experiment is achieved by using only one adjustable parameter, which leads to determination of the effective mass of heavy holes (~0.5m0).
Half-lives of 214Pb and 214Bi.
Martz, D E; Langner, G H; Johnson, P R
1991-10-01
New measurements on chemically separated samples of 214Bi have yielded a mean half-life value of 19.71 +/- 0.02 min, where the error quoted is twice the standard deviation of the mean based on 23 decay runs. This result provides strong support for the historic 19.72 +/- 0.04 min half-life value and essentially excludes the 19.9-min value, both reported in previous studies. New measurements of the decay rate of 222Rn progeny activity initially in radioactive equilibrium have yielded a value of 26.89 +/- 0.03 min for the half-life of 214Pb, where the error quoted is twice the standard deviation of the mean based on 12 decay runs. This value is 0.1 min longer than the currently accepted 214Pb half-value of 26.8 min.
NASA Technical Reports Server (NTRS)
Macfarlane, J. J.; Hubbard, W. B.
1983-01-01
A numerical technique for solving the Thomas-Fermi-Dirac (TED) equation in three dimensions, for an array of ions obeying periodic boundary conditions, is presented. The technique is then used to calculate deviations from ideal mixing for an alloy of hydrogen and helium at zero temperature and high presures. Results are compared with alternative models which apply perturbation theory to calculation of the electron distribution, based upon the assumption of weak response of the electron gas to the ions. The TFD theory, which permits strong electron response, always predicts smaller deviations from ideal mixing than would be predicted by perturbation theory. The results indicate that predicted phase separation curves for hydrogen-helium alloys under conditions prevailing in the metallic zones of Jupiter and Saturn are very model dependent.
Acoustic analysis of speech variables during depression and after improvement.
Nilsonne, A
1987-09-01
Speech recordings were made of 16 depressed patients during depression and after clinical improvement. The recordings were analyzed using a computer program which extracts acoustic parameters from the fundamental frequency contour of the voice. The percent pause time, the standard deviation of the voice fundamental frequency distribution, the standard deviation of the rate of change of the voice fundamental frequency and the average speed of voice change were found to correlate to the clinical state of the patient. The mean fundamental frequency, the total reading time and the average rate of change of the voice fundamental frequency did not differ between the depressed and the improved group. The acoustic measures were more strongly correlated to the clinical state of the patient as measured by global depression scores than to single depressive symptoms such as retardation or agitation.
Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2012-04-15
Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parametersmore » at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.« less
Patton, Gail Y.; Torgerson, Darrel D.
1987-01-01
An alignment reference device provides a collimated laser beam that minimizes angular deviations therein. A laser beam source outputs the beam into a single mode optical fiber. The output end of the optical fiber acts as a source of radiant energy and is positioned at the focal point of a lens system where the focal point is positioned within the lens. The output beam reflects off a mirror back to the lens that produces a collimated beam.
On the internal target model in a tracking task
NASA Technical Reports Server (NTRS)
Caglayan, A. K.; Baron, S.
1981-01-01
An optimal control model for predicting operator's dynamic responses and errors in target tracking ability is summarized. The model, which predicts asymmetry in the tracking data, is dependent on target maneuvers and trajectories. Gunners perception, decision making, control, and estimate of target positions and velocity related to crossover intervals are discussed. The model provides estimates for means, standard deviations, and variances for variables investigated and for operator estimates of future target positions and velocities.
[Strabismus surgery in Grave's disease--dose-effect relationships and functional results].
Schittkowski, M; Fichter, N; Guthoff, R
2004-11-01
Strabismus in thyroid ophthalmopathy is based on a loss of the contractility and distensibility of the external ocular muscles. Different therapeutic approaches are available, such as recession after pre-. or intraoperative measurement, adjustable sutures, antagonist resection, or contralateral synergist faden-operation. 26 patients with strabismus in thyroid ophthalmopathy were operated between 2000 and 2003. All patients were examined preoperatively, then 1 day and 3 - 6 months (maximum 36 months) postoperatively. Before proceeding with surgery, we waited at least 6 months after stabilization of ocular alignment and normalization of thyroid chemistry. Preoperative vertical deviation was 10-44 PD (mean 22), 3 months postoperatively it was 2-10 PD (mean 1.5). Recession of the fibrotic muscle leads to reproducible results: 3.98 +/- 0.52 PD vertical deviation/mm for the inferior rectus. In the case of a large preoperative deviation a correction should be expected, which might not be sufficient in the first few days or weeks; a second operation should not be carried out before 3 months. 7 patients were operated twice, 1 patient need three operations. 4 patients (preop. 0) achieved no double vision at all; 15 patients (preop. 1) had no double vision in the primary and reading positions; 3 patients (preop. 0) had no double vision with a maximum of 5 PD; 1 patient (preop. 7) had double vision in the primary or reading position even with prisms; and 2 patients (preop. 17) had double vision in every position. We advocate that recession of the restricted inferior or internal rectus muscle is precise, safe and effective in patients with thyroid ophthalmopathy. The recessed muscle should be fixed directly at the sclera to avoid late over-correction through a slipped muscle. The success rate in terms of binocular single vision was 76 % and 88 % with prisms added.
Contact Dependence and Velocity Crossover in Friction between Microscopic Solid/Solid Contacts.
McGraw, Joshua D; Niguès, Antoine; Chennevière, Alexis; Siria, Alessandro
2017-10-11
Friction at the nanoscale differs markedly from that between surfaces of macroscopic extent. Characteristically, the velocity dependence of friction between apparent solid/solid contacts can strongly deviate from the classically assumed velocity independence. Here, we show that a nondestructive friction between solid tips with radius on the scale of hundreds of nanometers and solid hydrophobic self-assembled monolayers has a strong velocity dependence. Specifically, using laterally oscillating quartz tuning forks, we observe a linear scaling in the velocity at the lowest accessed velocities, typically hundreds of micrometers per second, crossing over into a logarithmic velocity dependence. This crossover is consistent with a general multicontact friction model that includes thermally activated breaking of the contacts at subnanometric elongation. We find as well a strong dependence of the friction on the dimensions of the frictional probe.
Effect of Link Flexibility on tip position of a single link robotic arm
NASA Astrophysics Data System (ADS)
Madhusudan Raju, E.; Siva Rama Krishna, L.; Mouli, Y. Sharath Chandra; Nageswara Rao, V.
2015-12-01
The flexible robots are widely used in space applications due to their quick response, lower energy consumption, lower overall mass and operation at high speed compared to conventional industrial rigid link robots. These robots are inherently flexible, so that the kinematics of flexible robots can't be solved with rigid body assumptions. The flexibility in links and joints affects end-point positioning accuracy of the robot. It is important to model the link kinematics with precision which in turn simplifies modelling of dynamics of flexible robots. The main objective of this paper is to evaluate the effect of link flexibility on a tip position of a single link robotic arm for a given motion. The joint is assumed to be rigid and only link flexibility is considered. The kinematics of flexible link problem is evaluated by Assumed Modes Method (AMM) using MAT LAB Programming. To evaluate the effect of link flexibility (with and without payload) of robotic arm, the normalized tip deviation is found for flexible link with respect to a rigid link. Finally, the limiting inertia for payload mass is found if the allowable tip deviation is 5%.
Polar motion results from GEOS 3 laser ranging
NASA Technical Reports Server (NTRS)
Schutz, B. E.; Tapley, B. D.; Ries, J.; Eanes, R.
1979-01-01
The observability of polar motion from laser range data has been investigated, and the contributions from the dynamical and kinematical effects have been evaluated. Using 2-day arcs with GEOS 3 laser data, simultaneous solutions for pole position components and orbit elements have been obtained for a 2-week interval spanning August 27 to September 10, 1975, using three NASA Goddard Space Flight Center stations located at Washington, D.C., Bermuda, and Grand Turk. The results for the y-component of pole position from this limited data set differenced with the BIH linearly interpolated values yield a mean of 39 cm and a standard deviation of 1.07 m. Consideration of the variance associated with each estimate yields a mean of 20 cm and a standard deviation of 81 cm. The results for the x-component of pole position indicate that the mean value is in fair agreement with the BIH; however, the x-coordinate determination is weaker than the y-coordinate determination due to the distribution of laser sites (all three are between 77 deg W and 65 deg W) which results in greater sensitivity to the data distribution. In addition, the sensitivity of these results to various model parameters is discussed.
Distribution of kriging errors, the implications and how to communicate them
NASA Astrophysics Data System (ADS)
Li, Hong Yi; Milne, Alice; Webster, Richard
2016-04-01
Kriging in one form or another has become perhaps the most popular method for spatial prediction in environmental science. Each prediction is unbiased and of minimum variance, which itself is estimated. The kriging variances depend on the mathematical model chosen to describe the spatial variation; different models, however plausible, give rise to different minimized variances. Practitioners often compare models by so-called cross-validation before finally choosing the most appropriate for their kriging. One proceeds as follows. One removes a unit (a sampling point) from the whole set, kriges the value there and compares the kriged value with the value observed to obtain the deviation or error. One repeats the process for each and every point in turn and for all plausible models. One then computes the mean errors (MEs) and the mean of the squared errors (MSEs). Ideally a squared error should equal the corresponding kriging variance (σK2), and so one is advised to choose the model for which on average the squared errors most nearly equal the kriging variances, i.e. the ratio MSDR = MSE/σK2 ≈ 1. Maximum likelihood estimation of models almost guarantees that the MSDR equals 1, and so the kriging variances are unbiased predictors of the squared error across the region. The method is based on the assumption that the errors have a normal distribution. The squared deviation ratio (SDR) should therefore be distributed as χ2 with one degree of freedom with a median of 0.455. We have found that often the median of the SDR (MedSDR) is less, in some instances much less, than 0.455 even though the mean of the SDR is close to 1. It seems that in these cases the distributions of the errors are leptokurtic, i.e. they have an excess of predictions close to the true values, excesses near the extremes and a dearth of predictions in between. In these cases the kriging variances are poor measures of the uncertainty at individual sites. The uncertainty is typically under-estimated for the extreme observations and compensated for by over estimating for other observations. Statisticians must tell users when they present maps of predictions. We illustrate the situation with results from mapping salinity in land reclaimed from the Yangtze delta in the Gulf of Hangzhou, China. There the apparent electrical conductivity (ECa) of the topsoil was measured at 525 points in a field of 2.3 ha. The marginal distribution of the observations was strongly positively skewed, and so the observed ECas were transformed to their logarithms to give an approximately symmetric distribution. That distribution was strongly platykurtic with short tails and no evident outliers. The logarithms were analysed as a mixed model of quadratic drift plus correlated random residuals with a spherical variogram. The kriged predictions that deviated from their true values with an MSDR of 0.993, but with a medSDR=0.324. The coefficient of kurtosis of the deviations was 1.45, i.e. substantially larger than 0 for a normal distribution. The reasons for this behaviour are being sought. The most likely explanation is that there are spatial outliers, i.e. points at which the observed values that differ markedly from those at their their closest neighbours.
Distribution of kriging errors, the implications and how to communicate them
NASA Astrophysics Data System (ADS)
Li, HongYi; Milne, Alice; Webster, Richard
2015-04-01
Kriging in one form or another has become perhaps the most popular method for spatial prediction in environmental science. Each prediction is unbiased and of minimum variance, which itself is estimated. The kriging variances depend on the mathematical model chosen to describe the spatial variation; different models, however plausible, give rise to different minimized variances. Practitioners often compare models by so-called cross-validation before finally choosing the most appropriate for their kriging. One proceeds as follows. One removes a unit (a sampling point) from the whole set, kriges the value there and compares the kriged value with the value observed to obtain the deviation or error. One repeats the process for each and every point in turn and for all plausible models. One then computes the mean errors (MEs) and the mean of the squared errors (MSEs). Ideally a squared error should equal the corresponding kriging variance (σ_K^2), and so one is advised to choose the model for which on average the squared errors most nearly equal the kriging variances, i.e. the ratio MSDR=MSE/ σ_K2 ≈1. Maximum likelihood estimation of models almost guarantees that the MSDR equals 1, and so the kriging variances are unbiased predictors of the squared error across the region. The method is based on the assumption that the errors have a normal distribution. The squared deviation ratio (SDR) should therefore be distributed as χ2 with one degree of freedom with a median of 0.455. We have found that often the median of the SDR (MedSDR) is less, in some instances much less, than 0.455 even though the mean of the SDR is close to 1. It seems that in these cases the distributions of the errors are leptokurtic, i.e. they have an excess of predictions close to the true values, excesses near the extremes and a dearth of predictions in between. In these cases the kriging variances are poor measures of the uncertainty at individual sites. The uncertainty is typically under-estimated for the extreme observations and compensated for by over estimating for other observations. Statisticians must tell users when they present maps of predictions. We illustrate the situation with results from mapping salinity in land reclaimed from the Yangtze delta in the Gulf of Hangzhou, China. There the apparent electrical conductivity (EC_a) of the topsoil was measured at 525 points in a field of 2.3~ha. The marginal distribution of the observations was strongly positively skewed, and so the observed EC_as were transformed to their logarithms to give an approximately symmetric distribution. That distribution was strongly platykurtic with short tails and no evident outliers. The logarithms were analysed as a mixed model of quadratic drift plus correlated random residuals with a spherical variogram. The kriged predictions that deviated from their true values with an MSDR of 0.993, but with a medSDR=0.324. The coefficient of kurtosis of the deviations was 1.45, i.e. substantially larger than 0 for a normal distribution. The reasons for this behaviour are being sought. The most likely explanation is that there are spatial outliers, i.e. points at which the observed values that differ markedly from those at their their closest neighbours.
NASA Technical Reports Server (NTRS)
Hess, B. J.; Angelaki, D. E.
1997-01-01
The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.
Nucleotides containing variously modified sugars: energetics, structure, and mechanical properties.
Yurenko, Yevgen P; Novotný, Jan; Nikolaienko, Tymofii Yu; Marek, Radek
2016-01-21
The influence of various sugar residue modifications on intrinsic energetic, conformational, and mechanical properties of 2'-deoxyribonucleotide-5'-monophosphates (dNs) was comprehensively investigated using modern quantum chemical approaches. In total, fourteen sugar modifications, including double bonds and heteroatoms (S and N) inside the sugar ring, as well as fluorination in various positions, were analyzed. Among hundreds of possible conformational states of dNs, only two - AI and BI, corresponding to the most biologically significant forms of a double-helical DNA, were considered for each dN. It was established that the most of the studied modifications tend to strongly stabilize either AI or BI conformation of dNs both in the gas phase and in aqueous solution (modelled by implicit solvent models). Therefore, some of these modifications can be used as a tool for reducing structural polymorphism of nucleic acids in solution as well as for designing oligonucleotides with specific structural features. The evaluation of relaxed force constants (RFC) for glycosidic bonds suggests that the majority of the studied modifications of the sugar residue yield increased strengths of glycosidic bonds in dNs, and can therefore be used for designing modified nucleic acids with an increased resistance to abasic lesions. The most significant reinforcement of the glycosidic bond occurs in dNs containing the CF2 group instead of the O4' oxygen and the fluorine atom at the 2'-α-position. The calculation of the RFC and vibrational root-mean-square (VRMS) deviations for conformational degrees of freedom revealed a strong dependence between mechanical properties of dNs and their energetic characteristics. In particular, electronic energies of AI and BI conformers of dNs calculated in vacuo are closely connected with the values of relaxed force constants (RFC) for the δ angle: the higher RFC(δ) values correspond to more energetically favorable conformers.
The practice and clinical implications of tablet splitting in international health
Elliott, Ivo; Mayxay, Mayfong; Yeuichaixong, Sengchanh; Lee, Sue J; Newton, Paul N
2014-01-01
Objective Tablet splitting is frequently performed to facilitate correct dosing, but the practice and implications in low-income settings have rarely been discussed. Methods We selected eight drugs, with narrow therapeutic indices or critical dosages, frequently divided in the Lao PDR (Laos). These were split, by common techniques used in Laos, by four nurses and four laypersons. The mean percentage deviation from the theoretical expected weight and weight loss of divided tablets/capsules were recorded. Results Five of eight study drugs failed, on splitting, to meet European Pharmacopoeia recommendations for tablet weight deviation from the expected weight of tablet/capsule halves with 10% deviating by more than 25%. There was a significant difference in splitting accuracy between nurses and laypersons (P = 0.027). Coated and unscored tablets were less accurately split than uncoated (P = 0.03 and 0.0019 for each half) and scored (0.0001 for both halves) tablets. Conclusion These findings have potential clinical implications on treatment outcome and the development of antimicrobial resistance. Investment by drug companies in a wider range of dosage units, particularly for narrow therapeutic index and critical dosage medicines, is strongly recommended. PMID:24702766
Evaluation of the MV (CAPON) Coherent Doppler Lidar Velocity Estimator
NASA Technical Reports Server (NTRS)
Lottman, B.; Frehlich, R.
1997-01-01
The performance of the CAPON velocity estimator for coherent Doppler lidar is determined for typical space-based and ground-based parameter regimes. Optimal input parameters for the algorithm were determined for each regime. For weak signals, performance is described by the standard deviation of the good estimates and the fraction of outliers. For strong signals, the fraction of outliers is zero. Numerical effort was also determined.
"The Errors Were the Results of Errors": Promoting Good Writing by Bad Example
ERIC Educational Resources Information Center
Korsunsky, Boris
2010-01-01
We learn best by example--this adage is probably as old as teaching itself. In my own classroom, I have found that very often the students learn best from the "negative" examples. Perhaps, this shouldn't come as a surprise at all. After all, we don't react strongly to the norm--but an obvious deviation from the norm may attract our attention and…
Response of jammed packings to thermal fluctuations
NASA Astrophysics Data System (ADS)
Wu, Qikai; Bertrand, Thibault; Shattuck, Mark D.; O'Hern, Corey S.
2017-12-01
We focus on the response of mechanically stable (MS) packings of frictionless, bidisperse disks to thermal fluctuations, with the aim of quantifying how nonlinearities affect system properties at finite temperature. In contrast, numerous prior studies characterized the structural and mechanical properties of MS packings of frictionless spherical particles at zero temperature. Packings of disks with purely repulsive contact interactions possess two main types of nonlinearities, one from the form of the interaction potential (e.g., either linear or Hertzian spring interactions) and one from the breaking (or forming) of interparticle contacts. To identify the temperature regime at which the contact-breaking nonlinearities begin to contribute, we first calculated the minimum temperatures Tc b required to break a single contact in the MS packing for both single- and multiple-eigenmode perturbations of the T =0 MS packing. We find that the temperature required to break a single contact for equal velocity-amplitude perturbations involving all eigenmodes approaches the minimum value obtained for a perturbation in the direction connecting disk pairs with the smallest overlap. We then studied deviations in the constant volume specific heat C¯V and deviations of the average disk positions Δ r from their T =0 values in the temperature regime TC ¯V
Beyond Word Frequency: Bursts, Lulls, and Scaling in the Temporal Distributions of Words
Altmann, Eduardo G.; Pierrehumbert, Janet B.; Motter, Adilson E.
2009-01-01
Background Zipf's discovery that word frequency distributions obey a power law established parallels between biological and physical processes, and language, laying the groundwork for a complex systems perspective on human communication. More recent research has also identified scaling regularities in the dynamics underlying the successive occurrences of events, suggesting the possibility of similar findings for language as well. Methodology/Principal Findings By considering frequent words in USENET discussion groups and in disparate databases where the language has different levels of formality, here we show that the distributions of distances between successive occurrences of the same word display bursty deviations from a Poisson process and are well characterized by a stretched exponential (Weibull) scaling. The extent of this deviation depends strongly on semantic type – a measure of the logicality of each word – and less strongly on frequency. We develop a generative model of this behavior that fully determines the dynamics of word usage. Conclusions/Significance Recurrence patterns of words are well described by a stretched exponential distribution of recurrence times, an empirical scaling that cannot be anticipated from Zipf's law. Because the use of words provides a uniquely precise and powerful lens on human thought and activity, our findings also have implications for other overt manifestations of collective human dynamics. PMID:19907645
Wang, Ming; Li, Haoqing; Tian, Yujing; Guo, Hong; Fang, Xiaoying; Guo, Yuebin
2018-01-01
Changes in various grain interfaces, including the grain boundary and phase boundary, are a strong indication of microstructural changes, particularly ultra-fined grains achieved by large strain deformation and subsequent annealing. After direct rolling and cross rolling with the same strain of ε = 2, the distributions of the interfaces in annealed UNS S32304 duplex stainless steel were investigated using electron backscatter diffraction (EBSD) in this study. The ferrite experienced continued recovery, and a high density of low-angle grain boundaries (LAGBs) was produced. The percentage and number of twin boundaries (TBs) and LAGBs varied within the austenite. TBs were frequently found within austenite, showing a deviation from the Kurdjumov-Sachs (K-S) orientation relationship (OR) with ferrite matrix. However, LAGBs usually occur in austenite, with the K-S OR in the ferrite matrix. LAGBs were prevalent in the precipitated austenite grains, and therefore a strong texture was introduced in the cross-rolled and annealed samples, in which the precipitated austenite readily maintained the K-S OR in the ferrite matrix. By contrast, more TBs and a less robust texture were found in the precipitated austenite in direct-rolled and annealed samples, deviating from the K-S OR. PMID:29772723
76 FR 21636 - Drawbridge Operation Regulation; Illinois Waterway, Joliet, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-18
... participants in an 8K run to cross the bridge. This deviation allows the bridge to be maintained in the closed...-navigation position for three hours while an 8K run is held in the city of Joliet, IL. The Cass Street...
Placencia, A M; Peeler, J T
1999-01-01
A collaborative study involving 11 laboratories was conducted to measure the microbial barrier effectiveness of porous medical packaging. Two randomly cut samples from each of 6 commercially available porous materials and one positive and one negative control were tested by one operator in each of 11 laboratories. Microbial barrier effectiveness was measured in terms of logarithm reduction value (LRV), which reflects the log10 microbial penetration of the material being tested. The logarithm of the final concentration is subtracted from that of the initial concentration to obtain the LRV. Thus the higher the LRV, the better the barrier. Repeatability standard deviations ranged from 6.42 to 16.40; reproducibility standard deviations ranged from 15.50 to 22.70. Materials B(53), C(50), D(CT), and E(45MF) differ significantly from the positive control. The microbial ranking of porous packaging materials (exposure chamber method), ASTM method, has been adopted First Action by AOAC INTERNATIONAL.
A figure control sensor for the Large Deployable Reflector (LDR)
NASA Technical Reports Server (NTRS)
Bartman, R.; Dubovitsky, S.
1988-01-01
A sensing and control system is required to maintain high optical figure quality in a segmented reflector. Upon detecting a deviation of the segmented surface from its ideal form, the system drives segment mounted actuators to realign the individual segments and thereby return the surface to its intended figure. When the reflector is in use, a set of figure sensors will determine positions of a number of points on the back surface of each of the reflector's segments, each sensor being assigned to a single point. By measuring the positional deviations of these points from previously established nominal values, the figure sensors provide the control system with the information required to maintain the reflector's optical figure. The optical lever, multiple wavelength interferometer, and electronic capacitive sensor, the most promising technologies for the development of the figure sensor, are illustrated. It is concluded that to select a particular implementation of the figure sensors, performance requirement will be refined and relevant technologies investigated further.
An Ab Initio Based Potential Energy Surface for Water
NASA Technical Reports Server (NTRS)
Partridge, Harry; Schwenke, David W.; Langhoff, Stephen R. (Technical Monitor)
1996-01-01
We report a new determination of the water potential energy surface. A high quality ab initio potential energy surface (PES) and dipole moment function of water have been computed. This PES is empirically adjusted to improve the agreement between the computed line positions and those from the HITRAN 92 data base. The adjustment is small, nonetheless including an estimate of core (oxygen 1s) electron correlation greatly improves the agreement with experiment. Of the 27,245 assigned transitions in the HITRAN 92 data base for H2(O-16), the overall root mean square (rms) deviation between the computed and observed line positions is 0.125/cm. However the deviations do not correspond to a normal distribution: 69% of the lines have errors less than 0.05/cm. Overall, the agreement between the line intensities computed in the present work and those contained in the data base is quite good, however there are a significant number of line strengths which differ greatly.
On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy
NASA Astrophysics Data System (ADS)
Götz, Th I.; Ermer, M.; Salas-González, D.; Kellermeier, M.; Strnad, V.; Bert, Ch; Hensel, B.; Tomé, A. M.; Lang, E. W.
2017-10-01
High dose rate brachytherapy affords a frequent reassurance of the precise dwell positions of the radiation source. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni—or bi—modal heavy—tailed distributions. The latter are well represented by α—stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment.
Symmetry analysis of talus bone: A Geometric morphometric approach.
Islam, K; Dobbe, A; Komeili, A; Duke, K; El-Rich, M; Dhillon, S; Adeeb, S; Jomha, N M
2014-01-01
The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones. Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified. Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery. We conclude that left and right talus bones of intact human ankle joints show a strong degree of symmetry. The results of this study may have significance with respect to talus surgery, and in investigating traumatic talus injury where the geometric shape of the contralateral talus can be used as control. Cite this article: Bone Joint Res 2014;3:139-45.
Efficiency of thin magnetically arrested discs around black holes
NASA Astrophysics Data System (ADS)
Avara, Mark J.; McKinney, Jonathan C.; Reynolds, Christopher S.
2016-10-01
The radiative and jet efficiencies of thin magnetized accretion discs around black holes (BHs) are affected by BH spin and the presence of a magnetic field that, when strong, could lead to large deviations from Novikov-Thorne (NT) thin disc theory. To seek the maximum deviations, we perform general relativistic magnetohydrodynamic simulations of radiatively efficient thin (half-height H to radius R of H/R ≈ 0.10) discs around moderately rotating BHs with a/M = 0.5. First, our simulations, each evolved for more than 70 000 rg/c (gravitational radius rg and speed of light c), show that large-scale magnetic field readily accretes inward even through our thin disc and builds-up to the magnetically arrested disc (MAD) state. Secondly, our simulations of thin MADs show the disc achieves a radiative efficiency of ηr ≈ 15 per cent (after estimating photon capture), which is about twice the NT value of ηr ˜ 8 per cent for a/M = 0.5 and gives the same luminosity as an NT disc with a/M ≈ 0.9. Compared to prior simulations with ≲10 per cent deviations, our result of an ≈80 per cent deviation sets a new benchmark. Building on prior work, we are now able to complete an important scaling law which suggests that observed jet quenching in the high-soft state in BH X-ray binaries is consistent with an ever-present MAD state with a weak yet sustained jet.
Symmetry analysis of talus bone
Islam, K.; Dobbe, A.; Komeili, A.; Duke, K.; El-Rich, M.; Dhillon, S.; Adeeb, S.; Jomha, N. M.
2014-01-01
Objective The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones. Methods Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified. Results Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery. Conclusions We conclude that left and right talus bones of intact human ankle joints show a strong degree of symmetry. The results of this study may have significance with respect to talus surgery, and in investigating traumatic talus injury where the geometric shape of the contralateral talus can be used as control. Cite this article: Bone Joint Res 2014;3:139–45. PMID:24802391
Suppression of Self-Induced Flavor Conversion in the Supernova Accretion Phase
NASA Astrophysics Data System (ADS)
Sarikas, Srdjan; Raffelt, Georg G.; Hüdepohl, Lorenz; Janka, Hans-Thomas
2012-02-01
Self-induced flavor conversions of supernova (SN) neutrinos can strongly modify the flavor-dependent fluxes. We perform a linearized flavor stability analysis with accretion-phase matter profiles of a 15M⊙ spherically symmetric model and corresponding neutrino fluxes. We use realistic energy and angle distributions, the latter deviating strongly from quasi-isotropic emission, thus accounting for both multiangle and multienergy effects. For our matter and neutrino density profile we always find stable conditions: flavor conversions are limited to the usual Mikheyev-Smirnov-Wolfenstein effect. In this case one may distinguish the neutrino mass hierarchy in a SN neutrino signal if the mixing angle θ13 is as large as suggested by recent experiments.
Suppression of self-induced flavor conversion in the supernova accretion phase.
Sarikas, Srdjan; Raffelt, Georg G; Hüdepohl, Lorenz; Janka, Hans-Thomas
2012-02-10
Self-induced flavor conversions of supernova (SN) neutrinos can strongly modify the flavor-dependent fluxes. We perform a linearized flavor stability analysis with accretion-phase matter profiles of a 15M[symbol: see text] spherically symmetric model and corresponding neutrino fluxes. We use realistic energy and angle distributions, the latter deviating strongly from quasi-isotropic emission, thus accounting for both multiangle and multienergy effects. For our matter and neutrino density profile we always find stable conditions: flavor conversions are limited to the usual Mikheyev-Smirnov-Wolfenstein effect. In this case one may distinguish the neutrino mass hierarchy in a SN neutrino signal if the mixing angle θ13 is as large as suggested by recent experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuddy-Walsh, SG; University of Ottawa Heart Institute; Wells, RG
2014-08-15
Myocardial perfusion imaging (MPI) with Single Photon Emission Computed Tomography (SPECT) is invaluable in the diagnosis and management of heart disease. It provides essential information on myocardial blood flow and ischemia. Multi-pinhole dedicated cardiac-SPECT cameras offer improved count sensitivity, and spatial and energy resolutions over parallel-hole camera designs however variable sensitivity across the field-of-view (FOV) can lead to position-dependent noise variations. Since MPI evaluates differences in the signal-to-noise ratio, noise variations in the camera could significantly impact the sensitivity of the test for ischemia. We evaluated the noise characteristics of GE Healthcare's Discovery NM530c camera with a goal of optimizingmore » the accuracy of our patient assessment and thereby improving outcomes. Theoretical sensitivity maps of the camera FOV, including attenuation effects, were estimated analytically based on the distance and angle between the spatial position of a given voxel and each pinhole. The standard deviation in counts, σ was inferred for each voxel position from the square root of the sensitivity mapped at that position. Noise was measured experimentally from repeated (N=16) acquisitions of a uniform spherical Tc-99m-water phantom. The mean (μ) and standard deviation (σ) were calculated for each voxel position in the reconstructed FOV. Noise increased ∼2.1× across a 12 cm sphere. A correlation of 0.53 is seen when experimental noise is compared with theory suggesting that ∼53% of the noise is attributed to the combined effects of attenuation and the multi-pinhole geometry. Further investigations are warranted to determine the clinical impact of the position-dependent noise variation.« less
Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A
2018-05-01
This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Local and regional species diversity of benthic Isopoda (Crustacea) in the deep Gulf of Mexico
NASA Astrophysics Data System (ADS)
Wilson, George D. F.
2008-12-01
Recent studies of deep-sea faunas considered the influence of mid-domain models in the distribution of species diversity and richness with depth. In this paper, I show that separating local diversity from regional species richness in benthic isopods clarifies mid-domain effects in the distribution of isopods in the Gulf of Mexico. Deviations from the randomised implied species ranges can be informative to understanding general patterns within the Gulf of Mexico. The isopods from the GoMB study contained 135 species, with a total of 156 species including those from an earlier study. More than 60 species may be new to science. Most families of deep-sea isopods (suborder Asellota) were present, although some were extremely rare. The isopod family Desmosomatidae dominated the samples, and one species of Macrostylis (Macrostylidae) was found in many samples. Species richness for samples pooled within sites ranged from 1 to 52 species. Because species in pooled samples were highly correlated with individuals, species diversity was compared across sites using the expected species estimator ( n=15 individuals, ES 15). Six depth transects had idiosyncratic patterns of ES 15, and transects with the greatest short-range variation in topography, such as basins and canyons, had the greatest short-range disparity. Basins on the deep slope did not have a consistent influence (i.e., relatively higher or lower than surrounding areas) on the comparative species diversity. ES 15 of all transects together showed a weak mid-domain effect, peaking around 1200-1500 m, with low values at the shallowest and deepest samples (Sigsbee Abyssal Plain); no longitudinal (east-west) pattern was found. The regional species pool was analyzed by summing the implied ranges of all species. The species ranges in aggregate did not have significant patterns across longitudes, and many species had broad depth ranges, suggesting that the isopod fauna of the Gulf of Mexico is well dispersed. The summed ranges, as expected, had strong mid-domain patterns, contrasting with the local species richness estimates. The longitudinal ranges closely matched a randomized pattern (species ranges placed randomly, 1000 iterations), with significant deviations in the east attributable to lower sampling effort. The depth pattern, however, deviated from the mid-domain model, with a bimodal peak displaced nearly 500 m shallower than the mode of the randomized distribution. The deviations from random expectation were significantly positive above 1600 m and negative below 2000 m, with the result that regional species richness peaked between 800 and 1200 m, and decreased rapidly at deeper depths. The highest species richness intervals corresponded to the number of individuals collected. Residuals from a regression of the deviations on individual numbers, however, still deviated from the randomized pattern. In this declining depth-diversity pattern, the Gulf of Mexico resembles other partially enclosed basins, such as the Norwegian Sea, known to have suffered geologically recent extinction events. This displaced diversity pattern and broad depth ranges implicate ongoing re-colonization of the deeper parts of the Gulf of Mexico. The Sigsbee Abyssal Plain sites could be depauperate for historical reasons (e.g., one or more extinction events) rather than ongoing ecological reasons (e.g., low food supply).
Rosenlund, Signe; Holsgaard-Larsen, Anders; Overgaard, Søren; Jensen, Carsten
2016-01-01
The Gait Deviation Index summarizes overall gait 'quality', based on kinematic data from a 3-dimensional gait analysis. However, it is unknown which clinical outcomes may affect the Gait Deviation Index in patients with primary hip osteoarthritis. The aim of this study was to investigate associations between Gait Deviation Index as a measure of gait 'quality' and hip muscle strength and between Gait Deviation Index and patient-reported outcomes in patients with primary hip osteoarthritis. Forty-seven patients (34 males), aged 61.1 ± 6.7 years, with BMI 27.3 ± 3.4 (kg/m2) and with severe primary hip osteoarthritis underwent 3-dimensional gait analysis. Mean Gait Deviation Index, pain after walking and maximal isometric hip muscle strength (flexor, extensor, and abductor) were recorded. All patients completed the 'Physical Function Short-form of the Hip disability and Osteoarthritis Outcome Score (HOOS-Physical Function) and the Hip disability and Osteoarthritis Outcome Score subscales for pain (HOOS-Pain) and quality-of-life (HOOS-QOL). Mean Gait Deviation Index was positively associated with hip abduction strength (p<0.01, r = 0.40), hip flexion strength (p = 0.01, r = 0.37), HOOS-Physical Function (p<0.01, r = 0.41) HOOS-QOL (p<0.01, r = 0.41), and negatively associated with HOOS-Pain after walking (p<0.01, r = -0.45). Adjusting the analysis for walking speed did not affect the association. Patients with the strongest hip abductor and hip flexor muscles had the best gait 'quality'. Furthermore, patients with higher physical function, quality of life scores and lower pain levels demonstrated better gait 'quality'. These findings indicate that interventions aimed at improving hip muscle strength and pain management may to a moderate degree improve the overall gait 'quality' in patients with primary hip OA.