Sample records for structured diagnostic protocol

  1. Semantic Structures and Diagnostic Thinking of Experts and Novices.

    ERIC Educational Resources Information Center

    Bordage, Georges; Lemieux, Madeleine

    1991-01-01

    The diagnostic discourse of medical students and physicians in thinking-aloud protocols on paper cases was analyzed for evidence of semantic structure. Results show that structural semantics can be used to distinguish various levels of mental processing among novices as well as between novices and professionals. (MSE)

  2. Clinical outcomes and cost effectiveness of accelerated diagnostic protocol in a chest pain center compared with routine care of patients with chest pain.

    PubMed

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.

  3. Clinical Outcomes and Cost Effectiveness of Accelerated Diagnostic Protocol in a Chest Pain Center Compared with Routine Care of Patients with Chest Pain

    PubMed Central

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    Aims The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Methods and Results Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14–0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. Conclusion An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources. PMID:25622029

  4. Multiphysics Engineering Analysis for an Integrated Design of ITER Diagnostic First Wall and Diagnostic Shield Module Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Y.; Loesser, G.; Smith, M.

    ITER diagnostic first walls (DFWs) and diagnostic shield modules (DSMs) inside the port plugs (PPs) are designed to protect diagnostic instrument and components from a harsh plasma environment and provide structural support while allowing for diagnostic access to the plasma. The design of DFWs and DSMs are driven by 1) plasma radiation and nuclear heating during normal operation 2) electromagnetic loads during plasma events and associate component structural responses. A multi-physics engineering analysis protocol for the design has been established at Princeton Plasma Physics Laboratory and it was used for the design of ITER DFWs and DSMs. The analyses weremore » performed to address challenging design issues based on resultant stresses and deflections of the DFW-DSM-PP assembly for the main load cases. ITER Structural Design Criteria for In-Vessel Components (SDC-IC) required for design by analysis and three major issues driving the mechanical design of ITER DFWs are discussed. The general guidelines for the DSM design have been established as a result of design parametric studies.« less

  5. Quantifying Novice and Expert Differences in Visual Diagnostic Reasoning in Veterinary Pathology Using Eye-Tracking Technology.

    PubMed

    Warren, Amy L; Donnon, Tyrone L; Wagg, Catherine R; Priest, Heather; Fernandez, Nicole J

    2018-01-18

    Visual diagnostic reasoning is the cognitive process by which pathologists reach a diagnosis based on visual stimuli (cytologic, histopathologic, or gross imagery). Currently, there is little to no literature examining visual reasoning in veterinary pathology. The objective of the study was to use eye tracking to establish baseline quantitative and qualitative differences between the visual reasoning processes of novice and expert veterinary pathologists viewing cytology specimens. Novice and expert participants were each shown 10 cytology images and asked to formulate a diagnosis while wearing eye-tracking equipment (10 slides) and while concurrently verbalizing their thought processes using the think-aloud protocol (5 slides). Compared to novices, experts demonstrated significantly higher diagnostic accuracy (p<.017), shorter time to diagnosis (p<.017), and a higher percentage of time spent viewing areas of diagnostic interest (p<.017). Experts elicited more key diagnostic features in the think-aloud protocol and had more efficient patterns of eye movement. These findings suggest that experts' fast time to diagnosis, efficient eye-movement patterns, and preference for viewing areas of interest supports system 1 (pattern-recognition) reasoning and script-inductive knowledge structures with system 2 (analytic) reasoning to verify their diagnosis.

  6. An accelerated diagnostic protocol for the early, safe discharge of low-risk chest pain patients.

    PubMed

    Altherwi, Tawfeeq; Grad, Willis B

    2015-07-01

    Can an accelerated 2-hour diagnostic protocol using the cardiac troponin I (cTnI) measurement as the only biomarker be implemented to allow an earlier and safe discharge of low-risk chest pain patients? Than M, Cullen L, Aldous S, et al. 2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial. J Am Coll Cardiol 2012;59(23):2091-8. To determine whether an accelerated diagnostic protocol (ADP) for possible cardiac chest pain could identify low-risk patients suitable for early discharge using cTnI as the sole biomarker.

  7. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance.

    PubMed

    Guggenberger, Roman; Ulbrich, Erika J; Dietrich, Tobias J; Scholz, Rosemarie; Kaelin, Pascal; Köhler, Christoph; Elsässer, Thilo; Le Corroller, Thomas; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav

    2017-02-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.

  8. A decision-tree approach to the assessment of posttraumatic stress disorder: Engineering empirically rigorous and ecologically valid assessment measures.

    PubMed

    Stewart, Regan W; Tuerk, Peter W; Metzger, Isha W; Davidson, Tatiana M; Young, John

    2016-02-01

    Structured diagnostic interviews are widely considered to be the optimal method of assessing symptoms of posttraumatic stress; however, few clinicians report using structured assessments to guide clinical practice. One commonly cited impediment to these assessment approaches is the amount of time required for test administration and interpretation. Empirically keyed methods to reduce the administration time of structured assessments may be a viable solution to increase the use of standardized and reliable diagnostic tools. Thus, the present research conducted an initial feasibility study using a sample of treatment-seeking military veterans (N = 1,517) to develop a truncated assessment protocol based on the Clinician-Administered Posttraumatic Stress Disorder (PTSD) Scale (CAPS). Decision-tree analysis was utilized to identify a subset of predictor variables among the CAPS items that were most predictive of a diagnosis of PTSD. The algorithm-driven, atheoretical sequence of questions reduced the number of items administered by more than 75% and classified the validation sample at 92% accuracy. These results demonstrated the feasibility of developing a protocol to assess PTSD in a way that imposes little assessment burden while still providing a reliable categorization. (c) 2016 APA, all rights reserved).

  9. [The autopsy of the brain and spinal cord in the diagnosis of neurodegenerative diseases - a practical approach to optimize the examination].

    PubMed

    Rohan, Zdeněk; Matěj, Radoslav

    2015-01-01

    Brain and spinal cord autopsies aimed at neuropathological diagnosis of the causes of dementia and motor abnormalities are of increasing importance. Neuropathological brain examination is often the only diagnostic modality capable of definitive diagnosis of a neurodegenerative disease and thus serves as invaluable feedback for clinicians and biochemical and imaging diagnostics. The brain and spinal cord autopsy is performed following a standardized protocol and its goal is to sample all diagnostically relevant structures. Subsequent diagnostics are then done using standard and special histologic stainings, however state-of-the-art diagnostics can be achieved only using immunohistochemical methods. The purpose of the article is to provide the pathologists with a brief and practical guideline for brain and spinal cord autopsy when diagnosis of a neurodegenerative disease is suspected.

  10. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    PubMed

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  11. Diagnostic Yield and Economic Assessment of a Diagnostic Protocol With Systematic Use of an External Loop Recorder for Patients With Palpitations.

    PubMed

    Francisco-Pascual, Jaume; Santos-Ortega, Alba; Roca-Luque, Ivo; Rivas-Gándara, Nuria; Pérez-Rodón, Jordi; Milà-Pascual, Laia; García-Dorado, David; Moya-Mitjans, Àngel

    2018-05-24

    To assess the diagnostic yield and cost-effectiveness of a diagnostic protocol based on the systematic use of latest-generation external loop recorders (ELRs) compared with the classic diagnostic strategy for patients with recurrent unexplained palpitations. Two cohorts of consecutive patients referred for diagnosis of unexplained palpitations to the outpatient clinic of the arrhythmia unit were compared: a prospective cohort after the implementation of a new diagnostic protocol based on the systematic use of ELRs, and another, retrospective, cohort before the implementation of the protocol. The cost of diagnosis was calculated based on the number of complementary examinations, visits to outpatient clinics, or emergency department visits required to reach a diagnosis, and its costs according the prices published for the local health system. One hundred and forty-nine patients were included (91 in the ELR group, 58 in the control group). The diagnostic yield was higher in the ELR group (79 [86.8%] definitive diagnoses in the ELR group vs 12 [20.7%] in the control group, P < .001). The cost per diagnosis was €375.13 in the ELR group and €5184.75 in the control group (P < .001). The cost-effectiveness study revealed that the systematic use of ELR resulted in a cost reduction of €11.30 for each percentage point of increase in diagnosis yield. In patients with recurrent unexplained palpitations, evaluation by means of a study protocol that considers the systematic use of a latest-generation ELR increases diagnostic yield while reducing the cost per diagnosis. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Comparing Phytophthora ramorum diagnostic protocols for the national Sudden Oak death stream monitoring program

    Treesearch

    W. Sutton; E.M. Hansen; P. Reeser; A. Kanaskie

    2008-01-01

    Oregon was a participant in the pilot test of the national stream monitoring protocol for SOD. We routinely and continuously monitor about 50 streams in and near the SOD quarantine area in southwest Oregon using foliage baits. For the national protocol, we added six additional streams beyond the area of known infestation, and compared results from different diagnostic...

  13. Training and quality assurance with the Structured Clinical Interview for DSM-IV (SCID-I/P).

    PubMed

    Ventura, J; Liberman, R P; Green, M F; Shaner, A; Mintz, J

    1998-06-15

    Accuracy in psychiatric diagnosis is critical for evaluating the suitability of the subjects for entry into research protocols and for establishing comparability of findings across study sites. However, training programs in the use of diagnostic instruments for research projects are not well systematized. Furthermore, little information has been published on the maintenance of interrater reliability of diagnostic assessments. At the UCLA Research Center for Major Mental Illnesses, a Training and Quality Assurance Program for SCID interviewers was used to evaluate interrater reliability and diagnostic accuracy. Although clinically experienced interviewers achieved better interrater reliability and overall diagnostic accuracy than neophyte interviewers, both groups were able to achieve and maintain high levels of interrater reliability, diagnostic accuracy, and interviewer skill. At the first quality assurance check after training, there were no significant differences between experienced and neophyte interviewers in interrater reliability or diagnostic accuracy. Standardization of training and quality assurance procedures within and across research projects may make research findings from study sites more comparable.

  14. Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics

    NASA Astrophysics Data System (ADS)

    King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.

    2011-03-01

    The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.

  15. Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.

    PubMed

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2016-06-01

    The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The Structured Inventory of Malingered Symptomatology (SIMS): a systematic review and meta-analysis.

    PubMed

    van Impelen, Alfons; Merckelbach, Harald; Jelicic, Marko; Merten, Thomas

    2014-01-01

    We meta-analytically reviewed studies that used the Structured Inventory of Malingered Symptomatology (SIMS) to detect feigned psychopathology. We present weighted mean diagnostic accuracy and predictive power indices in various populations, based on 31 studies, including 61 subsamples and 4009 SIMS protocols. In addition, we provide normative data of patients, claimants, defendants, nonclinical adults, and various experimental feigners, based on 41 studies, including 125 subsamples and 4810 SIMS protocols. We conclude that the SIMS (1) is able to differentiate well between instructed feigners and honest responders; (2) generates heightened scores in groups that are known to have a raised prevalence of feigning (e.g., offenders who claim crime-related amnesia); (3) may overestimate feigning in patients who suffer from schizophrenia, intellectual disability, or psychogenic non-epileptic seizures; and (4) is fairly robust against coaching. The diagnostic power of the traditional cut scores of the SIMS (i.e., > 14 and > 16) is not so much limited by their sensitivity—which is satisfactory—but rather by their substandard specificity. This, however, can be worked around by combining the SIMS with other symptom validity measures and by raising the cut score, although the latter solution sacrifices sensitivity for specificity.

  17. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  18. Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

    PubMed

    Wuest, Wolfgang; May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael

    2016-11-01

    Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192x0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 × 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI vol 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. • Spectral optimization (tin filtration) is beneficial to low-dose parasinus CT • Tin filtration at 100 kV yields sufficient image quality for pre-operative planning • Diagnostic parasinus CT can be performed with an effective dose <0.05 mSv.

  19. 18F-FDG PET/CT in Detecting Metastatic Infection in Children.

    PubMed

    Kouijzer, Ilse J E; Blokhuis, Gijsbert J; Draaisma, Jos M T; Oyen, Wim J G; de Geus-Oei, Lioe-Fee; Bleeker-Rovers, Chantal P

    2016-04-01

    Metastatic infection is a severe complication of bacteremia with high morbidity and mortality. The aim of this study was to investigate the diagnostic value of 18F-FDG PET combined with CT (FDG PET/CT) in children suspected of having metastatic infection. The results of FDG PET/CT scans performed in children because of suspected metastatic infection from September 2003 to June 2013 were analyzed retrospectively. The results were compared with the final clinical diagnosis. FDG PET/CT was performed in 13 children with suspected metastatic infection. Of the total number of FDG PET/CT scans, 38% were clinically helpful. Positive predictive value of FDG PET/CT was 71%, and negative predictive value was 100%. FDG PET/CT appears to be a valuable diagnostic technique in children with suspected metastatic infection. Prospective studies of FDG PET/CT as part of a structured diagnostic protocol are needed to assess the exact additional diagnostic value.

  20. The Evolution of TMD Diagnosis

    PubMed Central

    Ohrbach, R.; Dworkin, S.F.

    2016-01-01

    This review explores the principles and process associated with the diagnosis of temporomandibular disorders (TMDs). TMD diagnosis has evolved substantially over the past 25 y. Previously, diagnosis focused solely on aberrations in oral structures, largely without empirical evidence. The Research Diagnostic Criteria for TMD (RDC/TMD) were developed on core principles of 1) a dual-axis system reflecting the biopsychosocial model, 2) a clear operationalization for reliability, and 3) the allowance of multiple diagnoses. These principles were retained in the subsequent validation research of the RDC/TMD, and the current diagnostic system—the Diagnostic Criteria for TMD (DC/TMD)—has improved on those principles as well as on diagnostic validity and protocols for assessing the psychosocial domain. Further investigations into etiology and its potential contribution to taxonomy revision are described, particularly within the context of complex disease. The review concludes with an outline of major research areas already underway that will support future revisions of the DC/TMD. PMID:27313164

  1. Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography.

    PubMed

    Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup

    2015-12-01

    The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, P<.001). The diagnostic acceptability was significantly lower in the low-concentration protocol with iterative reconstruction algorithm than in the conventional protocol (4.06±0.45 vs. 4.50±0.37, P<.001), however, all subjects showed at least more than standard diagnostic acceptability and the difference resided in the predefined non-inferiority margin. The signal-to-noise ratio, contrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (P<.001). CT urography using 240 mg I/mL iodine contrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. COMPARISON OF FUNCTIONAL ACTIVITIES ON STRUCTURAL CHANGES OF THE INFERIOR PATELLAR POLE

    PubMed Central

    Wallmann, Harvey; Stalcup, Patrick; DiTommaso, Katie

    2017-01-01

    Background It is well known that eccentric and concentric exercise produce varied amounts of stress on the connective tissues. Diagnostic ultrasound has been used to measure these structural changes by observing fascicle length, angle, and thickness; however, there is a lack of evidence comparing the structural changes as it relates to eccentric, concentric, and stretching protocols. Purpose The purpose of this study was to compare the acute effects of static stretching, eccentric, concentric, and a combination of eccentric/concentric exercises on structural changes of the muscle tendon unit at the inferior patellar pole utilizing the diagnostic ultrasound. Study Design A repeated measures 2 × 4 within factorial study design with repeated measures on both factors was used to determine the differences in patellar tendon thickness within and between groups. Methods Forty-seven healthy subjects were screened for any lower extremity deficits or orthopaedic pathology. Forty-four (N=44) subjects completed all four protocols; the attrition was due to injuries to the lower extremity, occurring unrelated to the study. A baseline measurement of the anterior inferior patellar tendon was performed with the diagnostic ultrasound prior to each participant completing one of the four interventions per week over a four-week period. Interventions completed by each participant included static stretching, concentric, eccentric, and combined concentric and eccentric exercises. Immediately following each intervention, a post-intervention inferior patellar tendon measurement was recorded using the diagnostic ultrasound. Results Significant differences in anterior to posterior tendon thickness of the inferior patellar tendon were observed between pre (4.983 ± 0.041mm) and post (5.198 ± 0.055mm) measurements (p<0.0005) for the main effect of time. However, no differences in tendon thickness were noted comparing each intervention to one another (p=0.351). Conclusion Differences in tendon thickness were noted acutely for pre- to post measurements across all interventions. Further research is needed to determine if differences in tendon thickness exist with a longer duration of exercise over time and with different types of intervention. PMID:29234561

  3. Implementation of a 5-Minute Magnetic Resonance Imaging Screening Protocol for Prostate Cancer in Men With Elevated Prostate-Specific Antigen Before Biopsy.

    PubMed

    Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios

    2018-03-01

    The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.

  4. Diagnostic and Therapeutic Knowledge and Practices in the Management of Congenital Syphilis by Pediatricians in Public Maternity Hospitals in Brazil.

    PubMed

    Dos Santos, Raquel Rodrigues; Niquini, Roberta Pereira; Bastos, Francisco Inácio; Domingues, Rosa Maria Soares Madeira

    2017-01-01

    The study aimed to assess conformity with Brazil's standard protocol for diagnostic and therapeutic practices in the management of congenital syphilis by pediatricians in public maternity hospitals. A cross-sectional study was conducted in 2015 with 41 pediatricians working in all the public maternity hospitals in Teresina, the capital of Piauí State, Northeast Brazil, through self-completed questionnaires. The study assessed the conformity of knowledge and practices according to the Brazilian Ministry of Health protocols. The study has made evident low access to training courses (54%) and insufficient knowledge of the case definition of congenital syphilis (42%) and rapid tests for syphilis (39%). Flaws were observed in the diagnostic workup and treatment of newborns. Requesting VDRL (88%) and correct treatment of neurosyphilis (88%) were the practices that showed the highest conformity with standard protocols. Low conformity with protocols leads to missed opportunities for identifying and adequately treating congenital syphilis. Based on the barriers identified in the study, better access to diagnostic and treatment protocols, improved recording on prenatal cards and hospital patient charts, availability of tests and medicines, and educational work with pregnant women should be urgently implemented, aiming to reverse the currently inadequate management of congenital syphilis and to curb its spread.

  5. Biparametric 3T Magnetic Resonance Imaging for prostatic cancer detection in a biopsy-naïve patient population: a further improvement of PI-RADS v2?

    PubMed

    Stanzione, Arnaldo; Imbriaco, Massimo; Cocozza, Sirio; Fusco, Ferdinando; Rusconi, Giovanni; Nappi, Carmela; Mirone, Vincenzo; Mangiapia, Francesco; Brunetti, Arturo; Ragozzino, Alfonso; Longo, Nicola

    2016-12-01

    To prospectively determine the diagnostic accuracy of a biparametric 3T magnetic resonance imaging protocol (BP-MRI) for prostatic cancer detection, compared to a multiparametric MRI protocol (MP-MRI), in a biopsy naïve patient population. Eighty-two untreated patients (mean age 65±7.6years) with clinical suspicion of prostate cancer and/or altered prostate-specific antigen (PSA) levels underwent a MP-MRI, including T2-weighted imaging, diffusion-weighted imaging (with the correspondent apparent diffusion coefficient maps) and dynamic contrast enhanced sequence, followed by prostate biopsy. Two radiologists reviewed both the BP-MRI and the MP-MRI protocols to establish a radiological diagnosis. Receiver operating characteristics curves were obtained to determine the diagnostic performance of the two protocols. The mean PSA level was 8.8±8.1ng/ml. A total of 34 prostatic tumors were identified, with a Gleason score that ranged from 3+3 to 5+4. Of these 34 tumors, 29 were located within the peripheral zone and 5 in the transitional zone. BP-MRI and MP-MRI showed a similar performance in terms of overall diagnostic accuracy, with an area under the curve of 0.91 and 0.93, respectively (p=n.s.). BP-MRI prostate protocol is feasible for prostatic cancer detection compared to a standard MP-MRI protocol, requiring a shorter acquisition and interpretation time, with comparable diagnostic accuracy to the conventional protocol, without the administration of gadolinium-based contrast agent. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. COMPARISON OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR™) AND MODEL-BASED ITERATIVE RECONSTRUCTION (VEO™) FOR PAEDIATRIC ABDOMINAL CT EXAMINATIONS: AN OBSERVER PERFORMANCE STUDY OF DIAGNOSTIC IMAGE QUALITY.

    PubMed

    Hultenmo, Maria; Caisander, Håkan; Mack, Karsten; Thilander-Klang, Anne

    2016-06-01

    The diagnostic image quality of 75 paediatric abdominal computed tomography (CT) examinations reconstructed with two different iterative reconstruction (IR) algorithms-adaptive statistical IR (ASiR™) and model-based IR (Veo™)-was compared. Axial and coronal images were reconstructed with 70 % ASiR with the Soft™ convolution kernel and with the Veo algorithm. The thickness of the reconstructed images was 2.5 or 5 mm depending on the scanning protocol used. Four radiologists graded the delineation of six abdominal structures and the diagnostic usefulness of the image quality. The Veo reconstruction significantly improved the visibility of most of the structures compared with ASiR in all subgroups of images. For coronal images, the Veo reconstruction resulted in significantly improved ratings of the diagnostic use of the image quality compared with the ASiR reconstruction. This was not seen for the axial images. The greatest improvement using Veo reconstruction was observed for the 2.5 mm coronal slices. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Clinical utility for diffusion MRI sequence in emergency and inpatient spine protocols.

    PubMed

    Hoch, Michael J; Rispoli, Joanne; Bruno, Mary; Wauchope, Mervin; Lui, Yvonne W; Shepherd, Timothy M

    Diffusion imaging of the spine has the potential to change clinical management, but is challenging due to the small size of the cord and susceptibility artifacts from adjacent structures. Reduced field-of-view (rFOV) diffusion can improve image quality by decreasing the echo train length. Over the past 2 years, we have acquired a rFOV diffusion sequence for MRI spine protocols on most inpatients and emergency room patients. We provide selected imaging diagnoses to illustrate the utility of including diffusion spine MRI in clinical practice. Our experiences support using diffusion MRI to improve diagnostic certainty and facilitate prompt treatment or clinical management. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Problem-solving strategies in psychiatry: differences between experts and novices in diagnostic accuracy and reasoning.

    PubMed

    Gabriel, Adel; Violato, Claudio

    2013-01-01

    The purpose of this study was to examine and compare diagnostic success and its relationship with the diagnostic reasoning process between novices and experts in psychiatry. Nine volunteers, comprising five expert psychiatrists and four clinical clerks, completed a think-aloud protocol while attempting to make a DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition) diagnosis of a selected case with both Axis I and Axis III diagnoses. Expert psychiatrists made significantly more successful diagnoses for both the primary psychiatric and medical diagnoses than clinical clerks. Expert psychiatrists also gave fewer differential options. Analyzing the think-aloud protocols, expert psychiatrists were much more organized, made fewer mistakes, and utilized significantly less time to access their knowledge than clinical clerks. Both novices and experts seemed to use the hypothetic-deductive and scheme-inductive approaches to diagnosis. However, experts utilized hypothetic-deductive approaches significantly more often than novices. The hypothetic-deductive diagnostic strategy was utilized more than the scheme-inductive approach by both expert psychiatrists and clinical clerks. However, a specific relationship between diagnostic reasoning and diagnostic success could not be identified in this small pilot study. The author recommends a larger study that would include a detailed analysis of the think-aloud protocols.

  9. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    PubMed

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  10. Diagnostic protocol for gestational diabetes mellitus (GDM) (IADPSG/ADA, 2011): influence on the occurrence of GDM and mild gestational hyperglycemia (MGH) and on the perinatal outcomes.

    PubMed

    Sirimarco, Mariana Pinto; Guerra, Helena Maciel; Lisboa, Eduardo Guimarães; Vernini, Joice Monalisa; Cassetari, Bianca Nicolosi; de Araujo Costa, Roberto Antonio; Rudge, Marilza Vieira Cunha; de Mattos Paranhos Calderon, Iracema

    2017-01-01

    In August 2011, the Specialized Center for Diabetes and Pregnancy of the Botucatu Medical School/Unesp adopted a new diagnostic protocol for gestational diabetes mellitus, recommended by the American Diabetes Association and the International Association of the Diabetes and Pregnancy Study Group. The glycemic profile was evaluated using the 75-g oral glucose tolerance test (OGTT) used to diagnose mild gestational hyperglycemia, recognized and treated in our department as gestational diabetes mellitus. The cost-effectiveness of the new guidelines and the continued need for the evaluation of the glycemic profile, as part of our Service protocol, are controversial and require further investigation. We aimed to assess the impact of the new guidelines on the evaluation of mild gestational hyperglycemia and gestational diabetes mellitus, the incidence of adverse perinatal outcomes, and the association between the 75-g OGTT and the glycemic profile for the diagnosis of mild gestational hyperglycemia. This cross-sectional study was performed identifying a convenience sample of pregnant women and their newborns. The women used our Service for diagnostic procedures, prenatal care and delivery, both before (January 2008 to August 14, 2011) and after (August 15, 2011 to December 2014) the protocol modification. The following variables were compared, following stratification according to diagnostic protocol: prevalence of gestational diabetes mellitus and mild gestational hyperglycemia, newborns large for gestational age, macrosomia, first cesarean delivery, and newborn hospital stay. Statistical analysis was performed using Poisson regression, the Student's t test, the Chi square or Fisher's exact test and risk estimate. The statistical significance threshold was set at 95% (p < 0.05). The new protocol resulted in an 85% increase in the number of women with GDM, but failed to identify 17.3% of pregnant women classified as having mild gestational hyperglycemia, despite a normal 75-g OGTT. The new guidelines did not affect perinatal outcome. These results support the validity of maintaining the glycemic profile as part of the diagnostic protocol at our hospital. Large multicenter studies with an adequate sample size are required for conclusive evidence on the cost-effectiveness of the new protocol.

  11. Diagnostic multiplex PCR for toxin genotyping of Clostridium perfringens isolates.

    PubMed

    Baums, Christoph G; Schotte, Ulrich; Amtsberg, Gunter; Goethe, Ralph

    2004-05-20

    In this study we provide a protocol for genotyping Clostridium perfringens with a new multiplex PCR. This PCR enables reliable and specific detection of the toxin genes cpa, cpb, etx, iap, cpe and cpb2 from heat lysed bacterial suspensions. The efficiency of the protocol was demonstrated by typing C. perfringens reference strains and isolates from veterinary bacteriological routine diagnostic specimens.

  12. The impact of extended longitudinal observation on the assessment of personality disorders.

    PubMed

    Pedersen, G; Karterud, S; Hummelen, B; Wilberg, T

    2013-11-01

    Multiple sources of information are necessary for a valid assessment of personality disorders (PDs). This study investigates the impact of longitudinal observation. The sample comprised 1217 patients from 15 different treatment units. PDs were assessed at admission to treatment using the Structured Clinical Interview for DSM-IV Axis II Personality Disorders (SCID-II) and additional clinical information (best estimate diagnosis). After approximately 18 weeks of treatment, the SCID-II protocols were re-examined at clinical conferences and the diagnostic status reassessed on the basis of longitudinal observations in multiple group situations (longitudinal, expert, all data principle). Using this procedure, 78% of the patients' diagnostic criteria sets were changed, and 32% of patients' diagnostic statuses were changed. Many (32%) patients who were evaluated initially as not having a PD received a PD diagnosis after re-examination. The information provided by customary clinical assessment has important limitations, and longitudinal observation provides additional information that may change the diagnostic status in approximately one-third of PD cases. Copyright © 2013 John Wiley & Sons, Ltd.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P., E-mail: Eiberg@dadlnet.d; Logager, Vibeke B., E-mail: viloe@heh.regionh.d

    The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as wellmore » as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.« less

  14. Nasal potential difference measurements in diagnosis of cystic fibrosis: an international survey.

    PubMed

    Naehrlich, Lutz; Ballmann, Manfred; Davies, Jane; Derichs, Nico; Gonska, Tanja; Hjelte, Lena; van Konigsbruggen-Rietschel, Silke; Leal, Teresinha; Melotti, Paola; Middleton, Peter; Tümmler, Burkhard; Vermeulen, Francois; Wilschanski, Michael

    2014-01-01

    The role of nasal potential difference (NPD) measurement as a diagnostic test for cystic fibrosis (CF) is a subject of global controversy because of the lack of validation studies, clear reference values, and standardized protocols for diagnostic NPD. To determine diagnostic NPD frequency, protocols, interpretation, and rater agreement, we surveyed the 18 NPD centres of the European Cystic Fibrosis Society Diagnostic Network Working Group. Fifteen centres reported performing 373 diagnostic NPDs in 2012. Most use the CFF-TDN-SOP (67%) and the chloride-free + isoproterenol response of the side with the largest response (47%) as diagnostic criteria and use centre-specific reference ranges. Rater agreement for five NPD tracings - in general - was good, but poor in tracings with different responses between the two nostrils. NPD is frequently used as a diagnostic and research tool for CF. Performance is highly standardized, centre-specific reference ranges are established, and rater agreement - in general - is good. Centre-independent diagnostic criteria and reference ranges must be defined by multicentre validation studies to improve standardized interpretation for diagnostic use. © 2013.

  15. Brain behavior relationships among African Americans, whites, and Hispanics.

    PubMed

    DeCarli, Charles; Reed, Bruce R; Jagust, William; Martinez, Oliver; Ortega, Mario; Mungas, Dan

    2008-01-01

    There is an increasing racial and ethnic diversity within the elderly population of the United States. Although increased diversity offers unique opportunities to study novel influences on aging and dementia, some aspects of racial and ethnic research have been hampered by the lack of culturally and linguistically consistent testing protocols. Structural brain imaging is commonly used to study the biology of normal aging and cognitive impairment and may therefore serve to explore potential biologic differences of cognitive impairment among racially and ethnically diverse individuals. To test this hypothesis, we recruited a cohort of approximately 400 African American, white, and Hispanic subjects with various degrees of cognitive ability. Each subject was carefully evaluated using standardized diagnostic protocols that included clinical review of brain magnetic resonance image (MRI) to arrive at a clinical diagnosis of normal cognition, mild cognitive impairment or dementia. Each MRI was then independently quantified for measures of brain, white matter hyperintensities, and hippocampal volumes by a technician blind to subject age, sex, ethnicity, race, and diagnostic category. The appearance of infarction on MRI was also rated by examining neurologists. Regression analyses were used to assess associations with various MRI measures across clinical diagnostic categories in relation to racial and ethnic differences. Hispanic subjects were, on average, significantly younger and had less years of education than African Americans or whites. Whites with dementia were significantly older than both African American and Hispanic dementia patients. Highly significant differences in MRI measures were associated with clinical diagnoses for the group as a whole after adjusting for the effects of age, sex, education, race, and ethnicity. Subsequent independent analyses by racial and ethnic status revealed consistent relationships between diagnostic category and MRI measures. Clinical diagnoses were associated with consistent differences in brain structure among a group of racially and ethnically diverse individuals. We believe these results help to validate current diagnostic assessment of individuals across a broad range of racial, ethnic, linguistic, and educational backgrounds. Moreover, interesting and potentially biologically relevant differences were found that might stimulate further research related to the understanding of dementia etiology within an increasingly racially and ethnically diverse population.

  16. Computed tomographic venography for varicose veins of the lower extremities: prospective comparison of 80-kVp and conventional 120-kVp protocols.

    PubMed

    Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee

    2012-01-01

    To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.

  17. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    PubMed Central

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra-articular disorder (sensitivity of 0.80 and specificity of 0.97). Diagnostic criteria for other common intra-articular disorders lack adequate validity for clinical diagnoses but can be used for screening purposes. Inter-examiner reliability for the clinical assessment associated with the validated DC/TMD criteria for pain-related TMD is excellent (kappa ≥ 0.85). Finally, a comprehensive classification system that includes both the common and less common TMD is also presented. The Axis II protocol retains selected original RDC/TMD screening instruments augmented with new instruments to assess jaw function as well as behavioral and additional psychosocial factors. The Axis II protocol is divided into screening and comprehensive self-report instrument sets. The screening instruments’ 41 questions assess pain intensity, pain-related disability, psychological distress, jaw functional limitations, and parafunctional behaviors, and a pain drawing is used to assess locations of pain. The comprehensive instruments, composed of 81 questions, assess in further detail jaw functional limitations and psychological distress as well as additional constructs of anxiety and presence of comorbid pain conditions. Conclusion The recommended evidence-based new DC/TMD protocol is appropriate for use in both clinical and research settings. More comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations. PMID:24482784

  18. [The value of bedside lung ultrasound in emergency-plus protocol for the assessment of lung consolidation and atelectasis in critical patients].

    PubMed

    Wang, Xiao-ting; Liu, Da-wei; Zhang, Hong-min; He, Huai-wu; Liu, Ye; Chai, Wen-zhao; Du, Wei

    2012-12-01

    To investigate the effect of the bedside lung ultrasound in emergency(BLUE)-plus lung ultrasound protocol on lung consolidation and atelectasis of critical patients. All patients who need to receive mechanical ventilation for more than 48 hours in ICU from June 2010 to December 2011 in Peking Union Medical College Hospital were included in the study. BLUE-plus and BLUE lung ultrasound, bedside X-ray, lung CT examination were performed on all patients at the same time. The condition of lung consolidation and atelectasis discovered by BLUE-plus lung ultrasound protocol was recorded and compared with bedside X-ray or lung CT. The difference in assessment of lung consolidation and atelectasis between BLUE-plus lung ultrasound protocol and BLUE protocol was compared. A total of 78 patients were finally enrolled in the study. The lung CT found 70 cases (89.74%) had different degrees of lung consolidation and atelectasis. The sensitivity, specificity and diagnostic accuracy of lung consolidation and atelectasis by the bedside chest X-ray were 31.29%, 75.00% and 38.46%, respectively. BLUE-plus lung ultrasound protocol found 68 cases with lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 95.71%, 87.50% and 94.87%, respectively, which were significantly higher than those of lung CT. BLUE protocol found 48 cases of lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 65.71%, 75.00% and 66.67%, respectively. The position of lung consolidation and atelectasis which hadn't been found by BLUE protocol was mainly proved to be located in the basement of lung by lung CT. The incidence of lung consolidation and atelectasis in critical patients who received mechanical ventilation is high. The BLUE-plus lung ultrasound protocol has a relatively higher sensitivity, specificity and diagnostic accuracy for consolidation and atelectasis, which can find majority of consolidation and atelectasis. As BLUE-plus lung ultrasound is a bedside noninvasive method allowing immediate assessment of most lung consolidation and atelectasis, it will be likely the alternative of the CT and play a key role in assessment of lung consolidation and atelectasis.

  19. Healthy individuals' perspectives on clinical research protocols and influences on enrollment decisions.

    PubMed

    Roberts, Laura Weiss; Kim, Jane Paik

    2017-01-01

    Understanding the perspectives of healthy individuals is important ethically and for the advancement of science. We assessed perceptions of risk associated with research procedures, comparing views of healthy individuals with and without experience in clinical research, and the respondents' reported willingness to volunteer. Semistructured interviews and written surveys were conducted. Study participants were healthy individuals, half of whom were currently enrolled in clinical research and half of whom had no prior experience in clinical research. Participants were queried regarding seven "minimal risk" or "greater than minimal risk" protocol vignettes with procedures of three types: routine diagnostic tests, more burdensome (i.e., more effort or potential harm) diagnostic tests, and pharmacologic interventions. Views of influences on enrollment decisions were also assessed. Most healthy individuals indicated that protocols with more burdensome or pharmacologic interventions were very risky (59%, 58%), as opposed to routine diagnostic test procedures (32%). Respondents' willingness to enroll in protocols varied by type of protocol (p value < .001) and was inversely correlated with risk assessments (regression coefficients from GEE = -0.4; -0.5; -0.7). The odds of healthy individuals with research experience expressing strong willingness to enroll in the depicted protocols were twice the odds of healthy individuals without research experience expressing the same level of willingness (OR = 2.0 95% CI: [1.1, 3.9]). Respondents did not assign risk categories as institutional review boards (IRBs) would, as indicated by low agreement (26%) between respondent and expert opinion on minimal risk protocols. Perceptions of procedure risk appear to influence healthy individuals' willingness to enroll in protocols. Participants with experience in clinical research were far more likely to express willingness to enroll, a finding with important scientific and ethical implications. The lack of alignment between healthy individuals' views of protocol risk and IRB categorization warrants further study.

  20. Optimization and validation of sample preparation for metagenomic sequencing of viruses in clinical samples.

    PubMed

    Lewandowska, Dagmara W; Zagordi, Osvaldo; Geissberger, Fabienne-Desirée; Kufner, Verena; Schmutz, Stefan; Böni, Jürg; Metzner, Karin J; Trkola, Alexandra; Huber, Michael

    2017-08-08

    Sequence-specific PCR is the most common approach for virus identification in diagnostic laboratories. However, as specific PCR only detects pre-defined targets, novel virus strains or viruses not included in routine test panels will be missed. Recently, advances in high-throughput sequencing allow for virus-sequence-independent identification of entire virus populations in clinical samples, yet standardized protocols are needed to allow broad application in clinical diagnostics. Here, we describe a comprehensive sample preparation protocol for high-throughput metagenomic virus sequencing using random amplification of total nucleic acids from clinical samples. In order to optimize metagenomic sequencing for application in virus diagnostics, we tested different enrichment and amplification procedures on plasma samples spiked with RNA and DNA viruses. A protocol including filtration, nuclease digestion, and random amplification of RNA and DNA in separate reactions provided the best results, allowing reliable recovery of viral genomes and a good correlation of the relative number of sequencing reads with the virus input. We further validated our method by sequencing a multiplexed viral pathogen reagent containing a range of human viruses from different virus families. Our method proved successful in detecting the majority of the included viruses with high read numbers and compared well to other protocols in the field validated against the same reference reagent. Our sequencing protocol does work not only with plasma but also with other clinical samples such as urine and throat swabs. The workflow for virus metagenomic sequencing that we established proved successful in detecting a variety of viruses in different clinical samples. Our protocol supplements existing virus-specific detection strategies providing opportunities to identify atypical and novel viruses commonly not accounted for in routine diagnostic panels.

  1. Patient-centred screening for primary immunodeficiency, a multi-stage diagnostic protocol designed for non-immunologists: 2011 update

    PubMed Central

    de Vries, E

    2012-01-01

    Members of the European Society for Immunodeficiencies (ESID) and other colleagues have updated the multi-stage expert-opinion-based diagnostic protocol for non-immunologists incorporating newly defined primary immunodeficiency diseases (PIDs). The protocol presented here aims to increase the awareness of PIDs among doctors working in different fields. Prompt identification of PID is important for prognosis, but this may not be an easy task. The protocol therefore starts from the clinical presentation of the patient. Because PIDs may present at all ages, this protocol is aimed at both adult and paediatric physicians. The multi-stage design allows cost-effective screening for PID of the large number of potential cases in the early phases, with more expensive tests reserved for definitive classification in collaboration with a specialist in the field of immunodeficiency at a later stage. PMID:22132890

  2. Issues of diagnostic review in brain tumor studies: from the Brain Tumor Epidemiology Consortium.

    PubMed

    Davis, Faith G; Malmer, Beatrice S; Aldape, Ken; Barnholtz-Sloan, Jill S; Bondy, Melissa L; Brännström, Thomas; Bruner, Janet M; Burger, Peter C; Collins, V Peter; Inskip, Peter D; Kruchko, Carol; McCarthy, Bridget J; McLendon, Roger E; Sadetzki, Siegal; Tihan, Tarik; Wrensch, Margaret R; Buffler, Patricia A

    2008-03-01

    Epidemiologists routinely conduct centralized single pathology reviews to minimize interobserver diagnostic variability, but this practice does not facilitate the combination of studies across geographic regions and institutions where diagnostic practices differ. A meeting of neuropathologists and epidemiologists focused on brain tumor classification issues in the context of protocol needs for consortial studies (http://epi.grants.cancer.gov/btec/). It resulted in recommendations relevant to brain tumors and possibly other rare disease studies. Two categories of brain tumors have enough general agreement over time, across regions, and between individual pathologists that one can consider using existing diagnostic data without further review: glioblastomas and meningiomas (as long as uniform guidelines such as those provided by the WHO are used). Prospective studies of these tumors benefit from collection of pathology reports, at a minimum recording the pathology department and classification system used in the diagnosis. Other brain tumors, such as oligodendroglioma, are less distinct and require careful histopathologic review for consistent classification across study centers. Epidemiologic study protocols must consider the study specific aims, diagnostic changes that have taken place over time, and other issues unique to the type(s) of tumor being studied. As diagnostic changes are being made rapidly, there are no readily available answers on disease classification issues. It is essential that epidemiologists and neuropathologists collaborate to develop appropriate study designs and protocols for specific hypothesis and populations.

  3. Retrospective analysis supports algorithm as efficient diagnostic approach to treatable intellectual developmental disabilities.

    PubMed

    Sayson, Bryan; Popurs, Marioara Angela Moisa; Lafek, Mirafe; Berkow, Ruth; Stockler-Ipsiroglu, Sylvia; van Karnebeek, Clara D M

    2015-05-01

    Intellectual developmental disorders (IDD(1)), characterized by a significant impairment in cognitive function and behavior, affect 2.5% of the population and are associated with considerable morbidity and healthcare costs. Inborn errors of metabolism (IEM) currently constitute the largest group of genetic defects presenting with IDD, which are amenable to causal therapy. Recently, we created an evidence-based 2-tiered diagnostic protocol (TIDE protocol); the first tier is a 'screening step' applied in all patients, comprising routinely performed, wide available metabolic tests in blood and urine, while second-tier tests are more specific and based on the patient's phenotype. The protocol is supported by an app (www.treatable-ID.org). To retrospectively examine the cost- and time-effectiveness of the TIDE protocol in patients identified with a treatable IEM at the British Columbia Children's Hospital. We searched the database for all IDD patients diagnosed with a treatable IEM, during the period 2000-2009 in our academic institution. Data regarding the patient's clinical phenotype, IEM, diagnostic tests and interval were collected. Total costs and time intervals associated with all testing and physician consultations actually performed were calculated and compared to the model of the TIDE protocol. Thirty-one patients (16 males) were diagnosed with treatable IDD during the period 2000-2009. For those identifiable via the 1st tier (n=20), the average cost savings would have been $311.17 CAD, and for those diagnosed via a second-tier test (n=11) $340.14 CAD. Significant diagnostic delay (mean 9 months; range 1-29 months) could have been avoided in 9 patients with first-tier diagnoses, had the TIDE protocol been used. For those with second-tier treatable IDD, diagnoses could have been more rapidly achieved with the use of the Treatable IDD app allowing for specific searches based on signs and symptoms. The TIDE protocol for treatable forms of IDD appears effective reducing diagnostic delay and unnecessary costs. Larger prospective studies, currently underway, are needed to prove that standard screening for treatable conditions in patients with IDD is time- and cost-effective, and most importantly will preserve brain function by timely diagnosis enabling initiation of causal therapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. What do providers, payers and patients need from comparative effectiveness research on diagnostics? The case of HER2/Neu testing in breast cancer.

    PubMed

    Trosman, Julia R; Weldon, Christine B; Schink, Julian C; Gradishar, William J; Benson, Al B

    2013-07-01

    Comparing effectiveness of diagnostic tests is one of the highest priorities for comparative effectiveness research (CER) set by the Institute of Medicine. Our study aims to identify what information providers, payers and patients need from CER on diagnostics, and what challenges they encounter implementing comparative information on diagnostic alternatives in practice and policy. Using qualitative research methods and the example of two alternative protocols for HER2 testing in breast cancer, we conducted interviews with 45 stakeholders: providers (n = 25) from four academic and eight nonacademic institutions, executives (n = 13) from five major US private payers and representatives (n = 7) from two breast cancer patient advocacies. The need for additional scientific evidence to determine the preferred HER2 protocol was more common for advocates than payers (100 vs 54%; p = 0.0515) and significantly more common for advocates than providers (100 vs 40%; p = 0.0077). The availability of information allowing assessment of the implementation impact from alternative diagnostic protocols on provider institutions may mitigate the need for additional scientific evidence for some providers and payers (24 and 46%, respectively). The cost-effectiveness of alternative protocols from the societal perspective is important to payers and advocates (69 and 71%, respectively) but not to providers (0%; p = 0.0001 and p = 0.0001). The lack of reporting laboratory practices is a more common implementation challenge for payers and advocates (77 and 86%, respectively) than for providers (32%). The absence of any mechanism for patient involvement was recognized as a challenge by payers and advocates (69 and 100%, respectively) but not by providers (0%; p = 0.0001 and p = 0.0001). Comparative implementation research is needed to inform the stakeholders considering diagnostic alternatives. Transparency of laboratory practices is an important factor in enabling implementation of CER on diagnostics in practice and policy. The incongruent views of providers versus patient advocates and payers on involving patients in diagnostic decisions is a concerning challenge to utilizing the results of CER.

  5. Automated processing of first-pass radioisotope ventriculography data to determine essential central circulation parameters

    NASA Astrophysics Data System (ADS)

    Krotov, Aleksei; Pankin, Victor

    2017-09-01

    The assessment of central circulation (including heart function) parameters is vital in the preventive diagnostics of inherent and acquired heart failures and during polychemotherapy. The protocols currently applied in Russia do not fully utilize the first-pass assessment (FPRNA) and that results in poor data formalization, while the FPRNA is the one of the fastest, affordable and compact methods among other radioisotope diagnostics protocols. A non-imaging algorithm basing on existing protocols has been designed to use the readings of an additional detector above vena subclavia to determine the total blood volume (TBV), not requiring blood sampling in contrast to current protocols. An automated processing of precordial detector readings is presented, in order to determine the heart strike volume (SV). Two techniques to estimate the ejection fraction (EF) of the heart are discussed.

  6. The Use of Protocols as Educational Tools for House Officers.

    ERIC Educational Resources Information Center

    Dworin, Aaron M.; Stross, Jeoffrey K.

    1979-01-01

    A project was initiated to determine whether protocols for the management of dysuria would be accepted by clinic house officers and whether these protocols could influence the care given to patients. Positive results were obtained in both areas. Significant improvement in documentation of patient history and diagnostic accuracy were noted. (JMD)

  7. Automatic image hanging protocol for chest radiographs in PACS.

    PubMed

    Luo, Hui; Hao, Wei; Foos, David H; Cornelius, Craig W

    2006-04-01

    Chest radiography is one of the most widely used techniques in diagnostic imaging. It comprises at least one-third of all diagnostic radiographic procedures in hospitals. However, in the picture archive and communication system, images are often stored with the projection and orientation unknown or mislabeled, which causes inefficiency for radiologists' interpretation. To address this problem, an automatic hanging protocol for chest radiographs is presented. The method targets the most effective region in a chest radiograph, and extracts a set of size-, rotation-, and translation-invariant features from it. Then, a well-trained classifier is used to recognize the projection. The orientation of the radiograph is later identified by locating the neck, heart, and abdomen positions in the radiographs. Initial experiments are performed on the radiographs collected from daily routine chest exams in hospitals and show promising results. Using the presented protocol, 98.2% of all cases could be hung correctly on projection view (without protocol, 62%), and 96.1% had correct orientation (without protocol, 75%). A workflow study on the protocol also demonstrates a significant improvement in efficiency for image display.

  8. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality.

    PubMed

    Hickethier, Tilman; Mammadov, Kamal; Baeßler, Bettina; Lichtenstein, Thorsten; Hinkelbein, Jochen; Smith, Lucy; Plum, Patrick Sven; Chon, Seung-Hun; Maintz, David; Chang, De-Hua

    2018-01-01

    The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs) for trauma patients using conventional or optimized patient positioning. Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging) and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning). Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%), liver (40 vs 8%) and spleen (27 vs 5%) occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality.

  9. Different protocols for cryobiopsy versus forceps biopsy in diagnosis of patients with endobronchial tumors.

    PubMed

    Jabari, Hamidreza; Sami, Ramin; Fakhri, Mohammad; Kiani, Arda

    2012-01-01

    Forceps biopsy is the standard procedure to obtain specimens in endobronchial lesions. New studies have proposed flexible cryoprobe as an accepted alternative method for this technique. Although diagnostic use of the cryobiopsy is confirmed in few studies, there is paucity of data with regard to an optimum protocol for this method since one of the main considerations in cryobiopsy is the freezing time. To evaluate diagnostic yield and safety of endobronchial biopsies using the flexible cryoprobe. Moreover, different freezing times were assessed to propose an optimized protocol for this diagnostic modality. For each patient with a confirmed intrabronchial lesion, diagnostic o value of forceps biopsy, cryobiopsy in three seconds, cryobiopsy in five seconds and combined results of cryobiopsy in both timings were recorded. A total of 60 patients (39 males and 21 females; Mean age 56.7 +/- 13.3) were included. Specimens that were obtained by cryobiopsy in five seconds were significantly larger than those of forceps biopsy and cryobiopsy in three seconds (p < 0.001). We showed that the achieved diagnostic yields for all three methods were not statistically different (p > 0.05). Simultaneous usage of samples produced in both cryobiopsies can significantly improve the diagnostic yield (p = 0.02). Statistical analysis showed that there were no significant differences in case of bleeding frequency among the three sampling methods. This study confirmed safety and feasibility of cryobiopsy. Additionally, combination of sampling with two different cold induction timings would significantly increase sensitivity of this emerging technique..

  10. Progeria Research Foundation Diagnostic Testing Program

    MedlinePlus

    ... Culture Protocols Immortalized Cell Culture Protocols Induced Pluripotent Stem Cells PRF Cell and Tissue Bank Publications Research Funding Opportunities Grant Application Application Deadlines Grants Funded Close Meet The Kids Meet The Kids Our Ambassadors Find The Other ...

  11. Measurement of fecal elastase improves performance of newborn screening for cystic fibrosis.

    PubMed

    Barben, Juerg; Rueegg, Corina S; Jurca, Maja; Spalinger, Johannes; Kuehni, Claudia E

    2016-05-01

    The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  12. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    PubMed

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  13. OMIP contribution to CMIP6: experimental and diagnostic protocol for the physical component of the Ocean Model Intercomparison Project

    NASA Astrophysics Data System (ADS)

    Griffies, Stephen M.; Danabasoglu, Gokhan; Durack, Paul J.; Adcroft, Alistair J.; Balaji, V.; Böning, Claus W.; Chassignet, Eric P.; Curchitser, Enrique; Deshayes, Julie; Drange, Helge; Fox-Kemper, Baylor; Gleckler, Peter J.; Gregory, Jonathan M.; Haak, Helmuth; Hallberg, Robert W.; Heimbach, Patrick; Hewitt, Helene T.; Holland, David M.; Ilyina, Tatiana; Jungclaus, Johann H.; Komuro, Yoshiki; Krasting, John P.; Large, William G.; Marsland, Simon J.; Masina, Simona; McDougall, Trevor J.; Nurser, A. J. George; Orr, James C.; Pirani, Anna; Qiao, Fangli; Stouffer, Ronald J.; Taylor, Karl E.; Treguier, Anne Marie; Tsujino, Hiroyuki; Uotila, Petteri; Valdivieso, Maria; Wang, Qiang; Winton, Michael; Yeager, Stephen G.

    2016-09-01

    The Ocean Model Intercomparison Project (OMIP) is an endorsed project in the Coupled Model Intercomparison Project Phase 6 (CMIP6). OMIP addresses CMIP6 science questions, investigating the origins and consequences of systematic model biases. It does so by providing a framework for evaluating (including assessment of systematic biases), understanding, and improving ocean, sea-ice, tracer, and biogeochemical components of climate and earth system models contributing to CMIP6. Among the WCRP Grand Challenges in climate science (GCs), OMIP primarily contributes to the regional sea level change and near-term (climate/decadal) prediction GCs.OMIP provides (a) an experimental protocol for global ocean/sea-ice models run with a prescribed atmospheric forcing; and (b) a protocol for ocean diagnostics to be saved as part of CMIP6. We focus here on the physical component of OMIP, with a companion paper (Orr et al., 2016) detailing methods for the inert chemistry and interactive biogeochemistry. The physical portion of the OMIP experimental protocol follows the interannual Coordinated Ocean-ice Reference Experiments (CORE-II). Since 2009, CORE-I (Normal Year Forcing) and CORE-II (Interannual Forcing) have become the standard methods to evaluate global ocean/sea-ice simulations and to examine mechanisms for forced ocean climate variability. The OMIP diagnostic protocol is relevant for any ocean model component of CMIP6, including the DECK (Diagnostic, Evaluation and Characterization of Klima experiments), historical simulations, FAFMIP (Flux Anomaly Forced MIP), C4MIP (Coupled Carbon Cycle Climate MIP), DAMIP (Detection and Attribution MIP), DCPP (Decadal Climate Prediction Project), ScenarioMIP, HighResMIP (High Resolution MIP), as well as the ocean/sea-ice OMIP simulations.

  14. Development of wide area environment accelerator operation and diagnostics method

    NASA Astrophysics Data System (ADS)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  15. Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma.

    PubMed

    Wurmb, T E; Quaisser, C; Balling, H; Kredel, M; Muellenbach, R; Kenn, W; Roewer, N; Brederlau, J

    2011-04-01

    Whole-body multislice helical CT becomes increasingly important as a diagnostic tool in patients with multiple injuries. Time gain in multiple-trauma patients who require emergency surgery might improve outcome. The authors hypothesised that whole-body multislice computed tomography (MSCT) (MSCT trauma protocol) as the initial diagnostic tool reduces the interval to start emergency surgery (tOR) if compared to conventional radiography, combined with abdominal ultrasound and organ-focused CT (conventional trauma protocol). The second goal of the study was to investigate whether the diagnostic approach chosen has an impact on outcome. The authors' level 1 trauma centre uses whole-body MSCT for initial radiological diagnostic work-up for patients with suspected multiple trauma. Before the introduction of MSCT in 2004, a conventional approach was used. Group I: data of trauma patients treated with conventional trauma protocol from 2001 to 2003. Group II: data from trauma patients treated with whole-body MSCT trauma protocol from 2004 to 2006. tOR in group I (n=155) was 120 (90-150) min (median and IQR) and 105 (85-133) min (median and IQR) in group II (n=163), respectively (p<0.05). Patients of group II had significantly more serious injuries. No difference in outcome data was found. 14 patients died in both groups within the first 30 days; five of these died within the first 24 h. A whole-body MSCT-based diagnostic approach to multiple trauma shortens the time interval to start emergency surgery in patients with multiple injuries. Mortality remained unchanged in both groups. Patients of group II were more seriously injured; an improvement of outcome might be assumed.

  16. Delving into cornerstones of hypersensitivity to antineoplastic and biological agents: value of diagnostic tools prior to desensitization.

    PubMed

    Alvarez-Cuesta, E; Madrigal-Burgaleta, R; Angel-Pereira, D; Ureña-Tavera, A; Zamora-Verduga, M; Lopez-Gonzalez, P; Berges-Gimeno, M P

    2015-07-01

    Evidence regarding drug provocation test (DPT) with antineoplastic and biological agents is scarce. Our aim was to assess the usefulness of including DPT as a paramount gold standard diagnostic tool (prior to desensitization). Prospective, observational, longitudinal study with patients who, during a 3-year period, were referred to the Desensitization Program at Ramon y Cajal University Hospital. Patients underwent a structured diagnostic protocol by means of anamnesis, skin tests (ST), risk assessment, and DPT. Oxaliplatin-specific IgE was determined in oxaliplatin-reactive patients (who underwent DPT regardless of oxaliplatin-specific IgE results). Univariate analysis and multivariate analysis were used to identify predictors of the final diagnosis among several variables. A total of 186 patients were assessed. A total of 104 (56%) patients underwent DPT. Sixty-four percent of all DPTs were negative (i.e., hypersensitivity was excluded). Sensitivity for oxaliplatin-specific IgE (0.35 UI/l cutoff point) was 34%, specificity 90.3%, negative predictive value 45.9%, positive predictive value 85%, negative likelihood ratio 0.7, and positive likelihood ratio 3.5. These are the first reported data based on more than 100 DPTs with antineoplastic and biological agents (paclitaxel, oxaliplatin, rituximab, infliximab, irinotecan, and other drugs). Implementation of DPT in diagnostic protocols helps exclude hypersensitivity (in 36% of all referred patients), and avoids unnecessary desensitizations in nonhypersensitive patients (30-56% of patients, depending on culprit-drug). Drug provocation test is vital to validate diagnostic tools; consequently, quality data are shown on oxaliplatin-specific IgE and oxaliplatin-ST in the largest series of oxaliplatin-reactive patients reported to date (74 oxaliplatin-reactive patients). Identifying phenotypes and predictors of a diagnosis of hypersensitivity may be helpful for tailored plans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 x-ray mammography findings.

    PubMed

    Bickelhaupt, Sebastian; Tesdorff, Jana; Laun, Frederik Bernd; Kuder, Tristan Anselm; Lederer, Wolfgang; Teiner, Susanne; Maier-Hein, Klaus; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter

    2017-02-01

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm 2 ). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. • Unenhanced breast MRI with additional DWIBS/T2w-image fusion allows reliable lesion characterization. • Abbreviated reading of fused DWIBS/T2w-images alone decreases diagnostic confidence and accuracy. • Reading fused DWIBS/T2w-images as the sole diagnostic method should be avoided.

  18. Spinal meningioma, aortic aneurysms and the missing link of observation: the anchoring heuristic approach.

    PubMed

    Floros, Nikolaos; Papadakis, Marios; Schelzig, Hubert; Oberhuber, Alexander

    2018-03-10

    Over the last three decades, the development of systematic and protocol-based algorithms, and advances in available diagnostic tests have become the indispensable parts of practising medicine. Naturally, despite the implementation of meticulous protocols involving diagnostic tests or even trials of empirical therapies, the cause of one's symptoms may still not be obvious. We herein report a case of chronic back pain, which took about 5 years to get accurately diagnosed. The case challenges the diagnostic assumptions and sets ground of discussion for the diagnostic reasoning pitfalls and heuristic biases that mislead the caring physicians and cost years of low quality of life to our patient. This case serves as an example of how anchoring heuristics can interfere in the diagnostic process of a complex and rare entity when combined with a concurrent potentially life-threatening condition. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Pulmonary Infiltrates in Immunosuppressed Patients: Analysis of a Diagnostic Protocol

    PubMed Central

    Danés, Cristina; González-Martín, Julián; Pumarola, Tomàs; Rañó, Ana; Benito, Natividad; Torres, Antoni; Moreno, Asunción; Rovira, Montserrat; Puig de la Bellacasa, Jorge

    2002-01-01

    A diagnostic protocol was started to study the etiology of pulmonary infiltrates in immunosuppressed patients. The diagnostic yields of the different techniques were analyzed, with special emphasis on the importance of the sample quality and the role of rapid techniques in the diagnostic strategy. In total, 241 patients with newly developed pulmonary infiltrates within a period of 19 months were included. Noninvasive or invasive evaluation was performed according to the characteristics of the infiltrates. Diagnosis was achieved in 202 patients (84%); 173 patients (72%) had pneumonia, and specific etiologic agents were found in 114 (66%). Bronchoaspirate and bronchoalveolar lavage showed the highest yields, either on global analysis (23 of 35 specimens [66%] and 70 of 134 specimens [52%], respectively) or on analysis of each type of pneumonia. A tendency toward better results with optimal-quality samples was observed, and a statistically significant difference was found in sputum bacterial culture. Rapid diagnostic tests yielded results in 71 of 114 (62.2%) diagnoses of etiological pneumonia. PMID:12037077

  20. Validating metal binding sites in macromolecule structures using the CheckMyMetal web server

    PubMed Central

    Zheng, Heping; Chordia, Mahendra D.; Cooper, David R.; Chruszcz, Maksymilian; Müller, Peter; Sheldrick, George M.

    2015-01-01

    Metals play vital roles in both the mechanism and architecture of biological macromolecules. Yet structures of metal-containing macromolecules where metals are misidentified and/or suboptimally modeled are abundant in the Protein Data Bank (PDB). This shows the need for a diagnostic tool to identify and correct such modeling problems with metal binding environments. The "CheckMyMetal" (CMM) web server (http://csgid.org/csgid/metal_sites/) is a sophisticated, user-friendly web-based method to evaluate metal binding sites in macromolecular structures in respect to 7350 metal binding sites observed in a benchmark dataset of 2304 high resolution crystal structures. The protocol outlines how the CMM server can be used to detect geometric and other irregularities in the structures of metal binding sites and alert researchers to potential errors in metal assignment. The protocol also gives practical guidelines for correcting problematic sites by modifying the metal binding environment and/or redefining metal identity in the PDB file. Several examples where this has led to meaningful results are described in the anticipated results section. CMM was designed for a broad audience—biomedical researchers studying metal-containing proteins and nucleic acids—but is equally well suited for structural biologists to validate new structures during modeling or refinement. The CMM server takes the coordinates of a metal-containing macromolecule structure in the PDB format as input and responds within a few seconds for a typical protein structure modeled with a few hundred amino acids. PMID:24356774

  1. Cognitive-behavioral group treatment for social phobia in adolescents. A preliminary study.

    PubMed

    Albano, A M; Marten, P A; Holt, C S; Heimberg, R G; Barlow, D H

    1995-10-01

    The present study is a preliminary evaluation of the effectiveness of a new cognitive-behavioral group treatment protocol for social phobia in adolescents. Five adolescents with social phobia were treated in a 16-session group treatment program, with parental involvement in selected sessions. Treatment involved skills training (social skills, problem solving, assertiveness), cognitive restructuring, behavioral exposure, and homework. Self-report measures of anxiety and depression, taken throughout treatment, indicated significant improvements over a 1-year follow-up period. Behavior test measures also indicated a decrease in subjective anxiety ratings after treatment which was maintained at follow-up. Structured diagnostic interviews 1 year after treatment confirmed full remission of social phobia for four subjects, with one subject's phobia in partial remission. Overall, the present findings support the continued evaluation of this protocol for social phobic adolescents.

  2. Fast and Noninvasive Characterization of Suspicious Lesions Detected at Breast Cancer X-Ray Screening: Capability of Diffusion-weighted MR Imaging with MIPs.

    PubMed

    Bickelhaupt, Sebastian; Laun, Frederik B; Tesdorff, Jana; Lederer, Wolfgang; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter

    2016-03-01

    To evaluate the ability of a diagnostic abbreviated magnetic resonance (MR) imaging protocol consisting of maximum intensity projections (MIPs) from diffusion-weighted imaging with background suppression (DWIBS) and unenhanced morphologic sequences to help predict the likelihood of malignancy on suspicious screening x-ray mammograms, as compared with an abbreviated contrast material-enhanced MR imaging protocol and a full diagnostic breast MR imaging protocol. This prospective institutional review board-approved study included 50 women (mean age, 57.1 years; range, 50-69 years), who gave informed consent and who had suspicious screening mammograms and an indication for biopsy, from September 2014 to January 2015. Before biopsy, full diagnostic contrast-enhanced MR imaging was performed that included DWIBS (b = 1500 sec/mm(2)). Two abbreviated protocols (APs) based on MIPs were evaluated regarding the potential to exclude malignancy: DWIBS (AP1) and subtraction images from the first postcontrast and the unenhanced series (AP2). Diagnostic indexes of both methods were examined by using the McNemar test and were compared with those of the full diagnostic protocol and histopathologic findings. Twenty-four of 50 participants had a breast carcinoma. With AP1 (DWIBS), the sensitivity was 0.92 (95% confidence interval [CI]: 0.73, 0.98), the specificity was 0.94 (95% CI: 0.77, 0.99), the negative predictive value (NPV) was 0.92 (95% CI: 0.75, 0.99), and the positive predictive value (PPV) was 0.93 (95% CI: 0.75, 0.99). The mean reading time was 29.7 seconds (range, 4.9-110.0 seconds) and was less than 3 seconds (range, 1.2-7.6 seconds) in the absence of suspicious findings on the DWIBS MIPs. With the AP2 protocol, the sensitivity was 0.85 (95% CI: 0.78, 0.95), the specificity was 0.90 (95% CI: 0.72, 0.97), the NPV was 0.87 (95% CI: 0.69, 0.95), the PPV was 0.89 (95% CI: 0.69, 0.97), and the mean reading time was 29.6 seconds (range, 6.0-100.0 seconds). Unenhanced diagnostic MR imaging (DWIBS mammography), with an NPV of 0.92 and an acquisition time of less than 7 minutes, could help exclude malignancy in women with suspicious x-ray screening mammograms. The method has the potential to reduce unnecessary invasive procedures and emotional distress for breast cancer screening participants if it is used as a complement after the regular screening clarification procedure.

  3. Screening for phaeochromocytoma and paraganglioma: impact of using supine reference intervals for plasma metanephrines with samples collected from fasted/seated patients.

    PubMed

    Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M

    2017-01-01

    Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.

  4. Moderate reagent mixing on an orbital shaker reduces the incubation time of enzyme-linked immunosorbent assay.

    PubMed

    Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip

    2017-07-01

    Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Economic evaluation of diagnostic methods used in dentistry. A systematic review.

    PubMed

    Christell, Helena; Birch, Stephen; Horner, Keith; Lindh, Christina; Rohlin, Madeleine

    2014-11-01

    To review the literature of economic evaluations regarding diagnostic methods used in dentistry. Four databases (MEDLINE, Web of Science, The Cochrane library, the NHS Economic Evaluation Database) were searched for studies, complemented by hand search, until February 2013. Two authors independently screened all titles or abstracts and then applied inclusion and exclusion criteria to select full-text publications published in English, which reported an economic evaluation comparing at least two alternative methods. Studies of diagnostic methods were assessed by four reviewers using a protocol based on the QUADAS tool regarding diagnostic methods and a check-list for economic evaluations. The results of the data extraction were summarized in a structured table and as a narrative description. From 476 identified full-text publications, 160 were considered to be economic evaluations. Only 12 studies (7%) were on diagnostic methods, whilst 78 studies (49%) were on prevention and 70 (40%) on treatment. Among studies on diagnostic methods, there was between-study heterogeneity methodologically, regarding the diagnostic method analysed and type of economic evaluation addressed. Generally, the choice of economic evaluation method was not justified and the perspective of the study not stated. Costing of diagnostic methods varied. A small body of literature addresses economic evaluation of diagnostic methods in dentistry. Thus, there is a need for studies from various perspectives with well defined research questions and measures of the cost and effectiveness. Economic resources in healthcare are finite. For diagnostic methods, an understanding of efficacy provides only part of the information needed for evidence-based practice. This study highlighted a paucity of economic evaluations of diagnostic methods used in dentistry, indicating that much of what we practise lacks sufficient evidence.

  6. Protocols for self-assembly and imaging of DNA nanostructures.

    PubMed

    Sobey, Thomas L; Simmel, Friedrich C

    2011-01-01

    Programed molecular structures allow us to research and make use of physical, chemical, and biological effects at the nanoscale. They are an example of the "bottom-up" approach to nanotechnology, with structures forming through self-assembly. DNA is a particularly useful molecule for this purpose, and some of its advantages include parallel (as opposed to serial) assembly, naturally occurring "tools," such as enzymes and proteins for making modifications and attachments, and structural dependence on base sequence. This allows us to develop one, two, and three dimensional structures that are interesting for their fundamental physical and chemical behavior, and for potential applications such as biosensors, medical diagnostics, molecular electronics, and efficient light-harvesting systems. We describe five techniques that allow one to assemble and image such structures: concentration measurement by ultraviolet absorption, titration gel electrophoresis, thermal annealing, fluorescence microscopy, and atomic force microscopy in fluids.

  7. Diagnostic accuracy of refractometer and Brix refractometer to assess failure of passive transfer in calves: protocol for a systematic review and meta-analysis.

    PubMed

    Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M

    2016-06-01

    Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.

  8. Two alternative DNA extraction methods to improve the detection of Mycobacterium-tuberculosis-complex members in cattle and red deer tissue samples.

    PubMed

    Fell, Shari; Bröckl, Stephanie; Büttner, Mathias; Rettinger, Anna; Zimmermann, Pia; Straubinger, Reinhard K

    2016-09-15

    Bovine tuberculosis (bTB), which is caused by Mycobacterium bovis and M. caprae, is a notifiable animal disease in Germany. Diagnostic procedure is based on a prescribed protocol that is published in the framework of German bTB legislation. In this protocol small sample volumes are used for DNA extraction followed by real-time PCR analyses. As mycobacteria tend to concentrate in granuloma and the infected tissue in early stages of infection does not necessarily show any visible lesions, it is likely that DNA extraction from only small tissue samples (20-40 mg) of a randomly chosen spot from the organ and following PCR testing may result in false negative results. In this study two DNA extraction methods were developed to process larger sample volumes to increase the detection sensitivity of mycobacterial DNA in animal tissue. The first extraction method is based on magnetic capture, in which specific capture oligonucleotides were utilized. These nucleotides are linked to magnetic particles and capture Mycobacterium-tuberculosis-complex (MTC) DNA released from 10 to 15 g of tissue material. In a second approach remaining sediments from the magnetic capture protocol were further processed with a less complex extraction protocol that can be used in daily routine diagnostics. A total number of 100 tissue samples from 34 cattle (n = 74) and 18 red deer (n = 26) were analyzed with the developed protocols and results were compared to the prescribed protocol. All three extraction methods yield reliable results by the real-time PCR analysis. The use of larger sample volume led to a sensitivity increase of DNA detection which was shown by the decrease of Ct-values. Furthermore five samples which were tested negative or questionable by the official extraction protocol were detected positive by real time PCR when the alternative extraction methods were used. By calculating the kappa index, the three extraction protocols resulted in a moderate (0.52; protocol 1 vs 3) to almost perfect agreement (1.00; red deer sample testing with all protocols). Both new methods yielded increased detection rates for MTC DNA detection in large sample volumes and consequently improve the official diagnostic protocol.

  9. Use of bacteriophage cell wall-binding proteins for rapid diagnostics of Listeria.

    PubMed

    Schmelcher, Mathias; Loessner, Martin J

    2014-01-01

    Diagnostic protocols for food-borne bacterial pathogens such as Listeria need to be sensitive, specific, rapid, and inexpensive. Conventional culture methods are hampered by lengthy enrichment and incubation steps. Bacteriophage-derived high-affinity binding molecules (cell wall-binding domains, CBDs) specific for Listeria cells have recently been introduced as tools for detection and differentiation of this pathogen in foods. When coupled with magnetic separation, these proteins offer advantages in sensitivity and speed compared to the standard diagnostic methods. Furthermore, fusion of CBDs to differently colored fluorescent reporter proteins enables differentiation of Listeria strains in mixed cultures. This chapter provides protocols for detection of Listeria in food by CBD-based magnetic separation and subsequent multiplexed identification of strains of different serotypes with reporter-CBD fusion proteins.

  10. Patient-centred screening for primary immunodeficiency: a multi-stage diagnostic protocol designed for non-immunologists

    PubMed Central

    de Vries, E

    2006-01-01

    Efficient early identification of primary immunodeficiency disease (PID) is important for prognosis, but is not an easy task for non-immunologists. The Clinical Working Party of the European Society for Immunodeficiencies (ESID) has composed a multi-stage diagnostic protocol that is based on expert opinion, in order to increase the awareness of PID among doctors working in different fields. The protocol starts from the clinical presentation of the patient; immunological skills are not needed for its use. The multi-stage design allows cost-effective screening for PID within the large pool of potential cases in all hospitals in the early phases, while more expensive tests are reserved for definitive classification in collaboration with an immunologist at a later stage. Although many PIDs present in childhood, others may present at any age. The protocols presented here are therefore aimed at both adult physicians and paediatricians. While designed for use throughout Europe, there will be national differences which may make modification of this generic algorithm necessary. PMID:16879238

  11. A BMI-adjusted ultra-low-dose CT angiography protocol for the peripheral arteries-Image quality, diagnostic accuracy and radiation exposure.

    PubMed

    Schreiner, Markus M; Platzgummer, Hannes; Unterhumer, Sylvia; Weber, Michael; Mistelbauer, Gabriel; Loewe, Christian; Schernthaner, Ruediger E

    2017-08-01

    To investigate radiation exposure, objective image quality, and the diagnostic accuracy of a BMI-adjusted ultra-low-dose CT angiography (CTA) protocol for the assessment of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the standard of reference. In this prospective, IRB-approved study, 40 PAD patients (30 male, mean age 72 years) underwent CTA on a dual-source CT scanner at 80kV tube voltage. The reference amplitude for tube current modulation was personalized based on the body mass index (BMI) with 120 mAs for [BMI≤25] or 150 mAs for [2570%) was assessed by two readers independently and compared to subsequent DSA. Radiation exposure was assessed with the computed tomography dose index (CTDIvol) and the dosis-length product (DLP). Objective image quality was assessed via contrast- and signal-to-noise ratio (CNR and SNR) measurements. Radiation exposure and image quality were compared between the BMI groups and between the BMI-adjusted ultra-low-dose protocol and the low-dose institutional standard protocol (ISP). The BMI-adjusted ultra-low-dose protocol reached high diagnostic accuracy values of 94% for Reader 1 and 93% for Reader 2. Moreover, in comparison to the ISP, it showed significantly (p<0.001) lower CTDIvol (1.97±0.55mGy vs. 4.18±0.62 mGy) and DLP (256±81mGy x cm vs. 544±83mGy x cm) but similar image quality (p=0.37 for CNR). Furthermore, image quality was similar between BMI groups (p=0.86 for CNR). A CT protocol that incorporates low kV settings with a personalized (BMI-adjusted) reference amplitude for tube current modulation and iterative reconstruction enables very low radiation exposure CTA, while maintaining good image quality and high diagnostic accuracy in the assessment of PAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-03-01

    To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Diagnostic Accuracy of an MRI Protocol of the Knee Accelerated Through Parallel Imaging in Correlation to Arthroscopy.

    PubMed

    Schnaiter, Johannes Walter; Roemer, Frank; McKenna-Kuettner, Axel; Patzak, Hans-Joachim; May, Matthias Stefan; Janka, Rolf; Uder, Michael; Wuest, Wolfgang

    2018-03-01

     Parallel imaging allows for a considerable shortening of examination times. Limited data is available about the diagnostic accuracy of an accelerated knee MRI protocol based on parallel imaging evaluating all knee joint compartments in a large patient population compared to arthroscopy.  162 consecutive patients with a knee MRI (1.5 T, Siemens Aera) and arthroscopy were included. The total MRI scan time was less than 9 minutes. Meniscus and cartilage injuries, cruciate ligament lesions, loose joint bodies and medial patellar plicae were evaluated. Sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV), as well as diagnostic accuracy were determined.  For the medial meniscus, the values were: SE 97 %, SP 88 %, PPV 94 %, and NPV 94 %. For the lateral meniscus the values were: SE 77 %, SP 99 %, PPV 98 %, and NPV 89 %. For cartilage injuries the values were: SE 72 %, SP 80 %, PPV 86 %, and NPV 61 %. For the anterior cruciate ligament the values were: SE 90 %, SP 94 %, PPV 77 %, and NPV 98 %, while all values were 100 % for the posterior cruciate ligament. For loose bodies the values were: SE 48 %, SP 96 %, PPV 62 %, and NPV 93 %, and for the medial patellar plicae the values were: SE 57 %, SP 88 %, PPV 18 %, and NPV 98 %.  A knee MRI examination with parallel imaging and a scan time of less than 9 minutes delivers reliable results with high diagnostic accuracy.   · An accelerated knee MRI protocol with parallel imaging allows for high diagnostic accuracy.. · Especially meniscal and cruciate ligament injuries are well depicted.. · Cartilage injuries seem to be overestimated.. · Schnaiter JW, Roemer F, McKenna-Kuettner A et al. Diagnostic Accuracy of an MRI Protocol of the Knee Accelerated Through Parallel Imaging in Correlation to Arthroscopy. Fortschr Röntgenstr 2018; 190: 265 - 272. © Georg Thieme Verlag KG Stuttgart · New York.

  14. 21 CFR 660.46 - Samples; protocols; official release.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Samples; protocols; official release. 660.46 Section 660.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface...

  15. Documentation Protocols to Generate Risk Indicators Regarding Degradation Processes for Cultural Heritage Risk Evaluation

    NASA Astrophysics Data System (ADS)

    Kioussi, A.; Karoglou, M.; Bakolas, A.; Labropoulos, K.; Moropoulou, A.

    2013-07-01

    Sustainable maintenance and preservation of cultural heritage assets depends highly on its resilience to external or internal alterations and to various hazards. Risk assessment of a heritage asset's can be defined as the identification of all potential hazards affecting it and the evaluation of the asset's vulnerability (building materials and building structure conservation state).Potential hazards for cultural heritage are complex and varying. The risk of decay and damage associated with monuments is not limited to certain long term natural processes, sudden events and human impact (macroscale of the heritage asset) but is also a function of the degradation processes within materials and structural elements due to physical and chemical procedures. Obviously, these factors cover different scales of the problem. The deteriorating processes in materials may be triggered by external influences or caused because of internal chemical and/or physical variations of materials properties and characteristics. Therefore risk evaluation should be dealt in the direction of revealing the specific active decay and damage mechanism both in mesoscale [type of decay and damage] and microscale [decay phenomenon mechanism] level. A prerequisite for risk indicators identification and development is the existence of an organised source of comparable and interoperable data about heritage assets under observation. This unified source of information offers a knowledge based background of the asset's vulnerability through the diagnosis of building materials' and building structure's conservation state, through the identification of all potential hazards affecting these and through mapping of its possible alterations during its entire life-time. In this framework the identification and analysis of risks regarding degradation processes for the development of qualitative and quantitative indicators can be supported by documentation protocols. The data investigated by such protocols help identify the parameters needed for the assessment of the preservation state of a monument and its monitoring through its entire lifetime. The main tool for detecting these indicators is a diagnostic methodology based on appropriate standards that reveals the actual degradation processes responsible of the asset's vulnerability. It is very important that the integration between the material's diagnosis and the overall documentation is taken into consideration in order to identify the required levels of protection and preventive conservation for heritage assets depending on the most frequent local risks. The ranging of risks is therefore necessary according to their importance in each area. Documentation protocols provide with a specific diagnostic tool for materials characterization, decay diagnosis, evaluation process of former conservation materials and interventions, standard procedures for monitoring and control as well as data documentation based on specific guidelines and standards. Implementation and analysis of a "standardised" diagnostic study will reveal the main risks due to degradation processes affecting the heritage asset to be subsequently recorded in order to result into risk indicators. The development of risk indicators regarding degradation processes is the basic step towards uptaking efficient management, preventive conservation and strategic planning for heritage assets against various threats. These risk indicators could be further elaborated according to the activities of inspection, diagnosis and intervention works, offering scientific support to the decision making process for cultural heritage preventive conservation and overall protection.

  16. [Long-term prognosis of idiopathic chronic adult hydrocephalus: I. The University Hospital Marqués de Valdecilla diagnostic and therapeutic protocol].

    PubMed

    Martín-Láez, Rubén; Vázquez-Barquero, Alfonso

    Despite the existence of published guidelines for more than a decade, there is still a substantial variation in the management of idiopathic normal pressure hydrocephalus due to its diagnostic and therapeutic complexity. The diagnostic and therapeutic protocol for the management of idiopathic normal pressure hydrocephalus in use at the Department of Neurosurgery of the University Hospital Marqués de Valdecilla is presented. The diagnostic process includes neuropsychological testing, phase contrast cine MRI, urodynamic evaluation, continuous intracranial pressure monitoring, cerebrospinal fluid hydrodynamics by means of lumbar infusion testing, and intra-abdominal pressure measurement. A patient is considered a surgical candidate if any of the following criteria is met: mean intracranial pressure >15mmHg, or B-waves present in >10% of overnight recording; pressure-volume index <15ml, or resistance to cerebrospinal fluid outflow (R OUT ) >4.5mmHg/ml/min in bolus infusion test; R OUT >12mmHg/ml/min, intracranial pressure >22mmHg, or high amplitude B-waves in the steady-state of the continuous rate infusion test; or a clinical response to high-volume cerebrospinal fluid withdrawal. The implementation of a diagnostic and therapeutic protocol for idiopathic normal pressure hydrocephalus management could improve various aspects of patient care. It could reduce variability in clinical practice, optimise the use of health resources, and help in identifying scientific uncertainty areas, in order to direct research efforts in a more appropriate way. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Cost-effectiveness of strategies used in the evaluation of pregnancies complicated by elevated maternal serum alpha-fetoprotein levels.

    PubMed

    Nadel, A S; Norton, M E; Wilkins-Haug, L

    1997-05-01

    To perform a cost-effectiveness analysis of various protocols used in the diagnostic evaluation of pregnancies complicated by elevated levels of maternal serum alpha-fetoprotein (MSAFP). The variables incorporated in this model were the prevalence of relevant fetal anomalies; the sensitivity and specificity of MSAFP at 2.0 or 2.5 multiples of the median (MoM); and the sensitivity, specificity, cost, and safety of targeted ultrasound and amniocentesis. We expressed the cost-effectiveness of each strategy as the total cost of the diagnostic evaluation divided by the number of anomalous fetuses identified, yielding the cost per identified anomalous fetus. In a hypothetical cohort of 100,000 singleton pregnancies, a strategy of targeted ultrasound for MSAFP of at least 2.0 MoM detected 90 of 110 structurally abnormal fetuses, without iatrogenic fetal loss, at a cost of $5700 per anomalous fetus. A strategy of amniocentesis with karyo-type determination for MSAFP of at least 2.5 MoM detected 15 additional abnormal fetuses (87 structural abnormalities, ten autosomal aneuploidies, and eight sex chromosomal aneuploidies), with nine iatrogenic fetal losses, at an incremental cost of $46,100 per anomalous fetus. The increased cost and iatrogenic fetal loss rate may not justify the increased diagnostic yield of amniocentesis as compared with ultrasound in the evaluation of pregnancies complicated by elevated MSAFP.

  18. [Protocols for the diagnostic verification of lymph node toxoplasmosis].

    PubMed

    Carosi, G; Ghezzi, L G; Filice, G; Maccabruni, A; Parisi, A; Carnevale, G

    1983-05-31

    The protocol we have fixed for the diagnosis of lymphonodal toxoplasmosis includes a precise succession of tests: 1) specific repeated serological tests (I.H.A.T., I.F.A.T., IgM--I.F.A.T. on total serum and on pure IgM fraction); 2) lymphonodal biopsy for histological examination and biological test (isolation procedure in mouse). We have evaluated the effectiveness of our protocol in 20 cases that we observed during 1980.

  19. Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

    PubMed

    Spin-Neto, Rubens; Gotfredsen, Erik; Wenzel, Ann

    2013-08-01

    The objective of this study was to make a systematic review on the impact of voxel size in cone beam computed tomography (CBCT)-based image acquisition, retrieving evidence regarding the diagnostic outcome of those images. The MEDLINE bibliographic database was searched from 1950 to June 2012 for reports comparing diverse CBCT voxel sizes. The search strategy was limited to English-language publications using the following combined terms in the search strategy: (voxel or FOV or field of view or resolution) and (CBCT or cone beam CT). The results from the review identified 20 publications that qualitatively or quantitatively assessed the influence of voxel size on CBCT-based diagnostic outcome, and in which the methodology/results comprised at least one of the expected parameters (image acquisition, reconstruction protocols, type of diagnostic task, and presence of a gold standard). The diagnostic task assessed in the studies was diverse, including the detection of root fractures, the detection of caries lesions, and accuracy of 3D surface reconstruction and of bony measurements, among others. From the studies assessed, it is clear that no general protocol can be yet defined for CBCT examination of specific diagnostic tasks in dentistry. Rationale in this direction is an important step to define the utility of CBCT imaging.

  20. A New Dual-purpose Quality Control Dosimetry Protocol for Diagnostic Reference-level Determination in Computed Tomography.

    PubMed

    Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh

    2018-05-17

    A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).

  1. Accuracy of Pediatric Trauma Field Triage: A Systematic Review.

    PubMed

    van der Sluijs, Rogier; van Rein, Eveline A J; Wijnand, Joep G J; Leenen, Luke P H; van Heijl, Mark

    2018-05-16

    Field triage of pediatric patients with trauma is critical for transporting the right patient to the right hospital. Mortality and lifelong disabilities are potentially attributable to erroneously transporting a patient in need of specialized care to a lower-level trauma center. To quantify the accuracy of field triage and associated diagnostic protocols used to identify children in need of specialized trauma care. MEDLINE, Embase, PsycINFO, and Cochrane Register of Controlled Trials were searched from database inception to November 6, 2017, for studies describing the accuracy of diagnostic tests to identify children in need of specialized trauma care in a prehospital setting. Identified articles with a study population including patients not transported by emergency medical services were excluded. Quality assessment was performed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies-2. After deduplication, 1430 relevant articles were assessed, a full-text review of 38 articles was conducted, and 5 of those articles were included. All studies were observational, published between 1996 and 2017, and conducted in the United States, and data collection was prospective in 1 study. Three different protocols were studied that analyzed a combined total of 1222 children in need of specialized trauma care. One protocol was specifically developed for a pediatric out-of-hospital cohort. The percentage of pediatric patients requiring specialized trauma care in each study varied between 2.6% (110 of 4197) and 54.7% (58 of 106). The sensitivity of the prehospital triage tools ranged from 49.1% to 87.3%, and the specificity ranged from 41.7% to 84.8%. No prehospital triage protocol alone complied with the international standard of 95% or greater sensitivity. Undertriage and overtriage rates, representative of the quality of the full diagnostic strategy to transport a patient to the right hospital, were not reported for inclusive trauma systems or emergency medical services regions. It is crucial to transport the right patient to the right hospital. Yet the quality of the full diagnostic strategy to determine the optimal receiving hospital is unknown. None of the investigated field triage protocols complied with current sensitivity targets. Improved efforts are needed to develop accurate child-specific tools to prevent undertriage and its potential life-threatening consequences.

  2. Studying Autism Spectrum Disorder with Structural and Diffusion Magnetic Resonance Imaging: A Survey

    PubMed Central

    Ismail, Marwa M. T.; Keynton, Robert S.; Mostapha, Mahmoud M. M. O.; ElTanboly, Ahmed H.; Casanova, Manuel F.; Gimel'farb, Georgy L.; El-Baz, Ayman

    2016-01-01

    Magnetic resonance imaging (MRI) modalities have emerged as powerful means that facilitate non-invasive clinical diagnostics of various diseases and abnormalities since their inception in the 1980s. Multiple MRI modalities, such as different types of the sMRI and DTI, have been employed to investigate facets of ASD in order to better understand this complex syndrome. This paper reviews recent applications of structural magnetic resonance imaging (sMRI) and diffusion tensor imaging (DTI), to study autism spectrum disorder (ASD). Main reported findings are sometimes contradictory due to different age ranges, hardware protocols, population types, numbers of participants, and image analysis parameters. The primary anatomical structures, such as amygdalae, cerebrum, and cerebellum, associated with clinical-pathological correlates of ASD are highlighted through successive life stages, from infancy to adulthood. This survey demonstrates the absence of consistent pathology in the brains of autistic children and lack of research investigations in patients under 2 years of age in the literature. The known publications also emphasize advances in data acquisition and analysis, as well as significance of multimodal approaches that combine resting-state, task-evoked, and sMRI measures. Initial results obtained with the sMRI and DTI show good promise toward the early and non-invasive ASD diagnostics. PMID:27242476

  3. High-resolution rapid diagnostic imaging of whole prostate biopsies using video-rate fluorescence structured illumination microscopy

    PubMed Central

    Wang, Mei; Kimbrell, Hillary Z.; Sholl, Andrew B.; Tulman, David B.; Elfer, Katherine N.; Schlichenmeyer, Tyler C.; Lee, Benjamin R.; Lacey, Michelle; Brown, J. Quincy

    2015-01-01

    Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced trans-rectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histological, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols such as frozen section analysis (FSA) are destructive, and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive non-destructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds, and contain excellent contrast and detail, exhibiting close correlation with corresponding H&E histology. A clinically-relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the ROC curve (AUC) of 0.82–0.88, with a sensitivity ranging from 63–88% and a specificity ranging from 78–89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75–92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure. PMID:26282168

  4. The biomarker-based diagnosis of Alzheimer's disease. 1-ethical and societal issues.

    PubMed

    Porteri, Corinna; Albanese, Emiliano; Scerri, Charles; Carrillo, Maria C; Snyder, Heather M; Martensson, Birgitta; Baker, Mark; Giacobini, Ezio; Boccardi, Marina; Winblad, Bengt; Frisoni, Giovanni B; Hurst, Samia

    2017-04-01

    There is great interest in the use of biomarkers to assist in the timely identification of Alzheimer's disease (AD) in individuals with mild symptoms. However, the inclusion of AD biomarkers in clinical criteria poses socioethical challenges. The Geneva Task Force for the Roadmap of Alzheimer's Biomarkers was established to deliver a systematic strategic research agenda (aka roadmap) to promote efficient and effective validation of AD biomarkers and to foster their uptake in clinical practice. In this article, we summarize the workshop discussion of the Geneva Task Force "ethical and societal issues" working group, which comprised bioethicists, clinicians, health economists, and representatives of those affected by AD. The working group identified the following key issues that need to be included in the roadmap: improving access to services through timely diagnosis, the need for a diagnostic research protocol before moving to clinical routine, recruitment in diagnostic research protocols in the absence of effective therapy, respect for the autonomy of the individual with mild cognitive impairment in information and consent process and the right not to know biomarkers results, need for counseling programs, disclosure of the diagnosis in a structured environment and the involvement of family members, health policies including the individuals' views and the protection of their interests, and the economic costs for society. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. A protocol for bladder cancer screening and medical surveillance among high-risk groups: The Drake Health Registry experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsh, G.M.; Callahan, C.; Pavlock, D.

    In 1986, the Drake Health Registry Study initiated bladder cancer screening for 366 persons at high risk because of occupational exposure to beta-naphthylamine. The Drake Health Registry Study screening protocol consists of urinalysis, Papanicolaou cytology, and quantitative fluorescence image analysis. A positive screening test qualifies participants for a full diagnostic evaluation. The screening protocol has been modified during the first 3 years of the program's existence to address unexpected patterns of test results and to incorporate advances in screening technology. The current protocol, which has a two-tiered screening schedule, has been utilized successfully for 15 months. Of the 26 positivemore » results to date most have been based on abnormal Papanicolaou cytology and/or quantitative fluorescence image analysis. Bladder abnormalities were cited among most of the 18 study members who underwent diagnostic evaluation, including chronic cystitis, inflammation, hyperplasia, and dysplasia. We conclude that the screening program is detecting very early changes in a relatively young cohort and that these persons must be monitored over a number of years to ensure adequate medical surveillance.« less

  6. High level expression, purification and physico- and immunochemical characterisation of recombinant Pen a 1: a major allergen of shrimp.

    PubMed

    Albrecht, Melanie; Alessandri, Stefano; Conti, Amedeo; Reuter, Andreas; Lauer, Iris; Vieths, Stefan; Reese, Gerald

    2008-11-01

    Well-characterised and immunologically active recombinant allergens are of eminent importance for improvement of diagnostic tools and immunotherapy of allergic diseases. The use of recombinant allergens has several advantages such as the more precise quantification of the active substance compared to allergen extracts and the reduced risk of contamination with other allergenic proteins compared to purified natural allergens. Optimised standard protocols for expression and purification and a detailed physico-chemical characterisation of such recombinant allergens are necessary to ensure consistent quality and comparability of results obtained with recombinant material. In this study the major allergen Pen a 1 of brown shrimp (Penaeus aztecus) was expressed in E. coli and purified in two steps by immobilised metal chelate-affinity chromatography (IMAC) and size-exclusion chromatography. Identity and purity were verified with N-terminal sequencing and peptide mass fingerprinting. Circular dichroism and NMR-spectroscopy indicated an alpha-helical flexible structure of rPen a 1 which is in accordance with the known structure of tropomyosins. Finally, the recombinant allergen proved to be immunologically reactive in IgE Western blot analysis and ELISA. This study provides a protocol for the preparation of recombinant shrimp tropomyosin in standardised quality.

  7. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    NASA Astrophysics Data System (ADS)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  8. Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.

    PubMed

    Masa, Juan F; Corral, Jaime; Pereira, Ricardo; Duran-Cantolla, Joaquin; Cabello, Marta; Hernández-Blasco, Luis; Monasterio, Carmen; Alonso-Fernandez, Alberto; Chiner, Eusebi; Vázquez-Polo, Francisco-José; Montserrat, Jose M

    2013-04-01

    Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.

  9. On-wire lithography: synthesis, encoding and biological applications

    PubMed Central

    Banholzer, Matthew J; Qin, Lidong; Millstone, Jill E; Osberg, Kyle D; Mirkin, Chad A

    2014-01-01

    The next step in the maturing field of nanotechnology is to develop ways to introduce unusual architectural changes to simple building blocks. For nanowires, on-wire lithography (OWL) has emerged as a powerful way of synthesizing a segmented structure and subsequently introducing architectural changes through post-chemical treatment. In the OWL protocol presented here, multisegmented nanowires are grown and a support layer is deposited on one side of each nanostructure. After selective chemical etching of sacrificial segments, structures with gaps as small as 2 nm and disks as thin as 20 nm can be created. These nanostructures are highly tailorable and can be used in electrical transport, Raman enhancement and energy conversion. Such nanostructures can be functionalized with many types of adsorbates, enabling the use of OWL-generated structures as bioactive probes for diagnostic assays and molecular transport junctions. The process takes 13–36 h depending on the type of adsorbate used to functionalize the nanostructures. PMID:19444241

  10. Chronic idiopathic anal pain. Results of a diagnostic-therapeutic protocol in a colorectal referral unit.

    PubMed

    Armañanzas, Laura; Arroyo, Antonio; Ruiz-Tovar, Jaime; López, Alberto; Santos, Jair; Moya, Pedro; Gómez, María Amparo; Candela, Fernando; Calpena, Rafael

    2015-01-01

    Chronic idiopathic anal pain (CIAP) remains a diagnosis of exclusion. Its study and management still lack a standardized protocol. The aim of this study is to evaluate the results obtained with the diagnostic-therapeutic protocol established in our service. We performed a retrospective study of patients diagnosed with CIAP at the Colorectal Unit of the General University Hospital of Elche, between 2005 and 2011. We evaluated 57 patients with a diagnosis of chronic anal pain for functional anorectal disease (FAD). After the application of our diagnostic protocol, final diagnosis of chronic anal pain (CAP) was achieved in 43 cases (75%), including 22 cases of descending perineum syndrome, 12 of proctalgia fugax, 2 of pudendal neuritis and 7 of coccydynia. In 14 patients exclusion diagnosis of CIAP was established. Among the therapies used on patients with CIAP, biofeedback combined with conservative measures improved symptoms in 43% of the cases. Sacral nerve stimulation was assessed in patients who did not respond to other treatments. Through proper anamnesis, physical examination and complementary tests, a specific diagnosis of the cause of CAP by FAD can be achieved, reducing exclusion diagnosis of CIAP to 25% of cases. Conservative measures combined with biofeedback achieved an improvement in pain in more than 40% of the cases of CIAP in our study. Sacral nerve stimulation can be considered as a treatment option in refractory cases. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. 40 CFR 1048.110 - How must my engines diagnose malfunctions?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...

  12. 40 CFR 1048.110 - How must my engines diagnose malfunctions?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...

  13. 40 CFR 1048.110 - How must my engines diagnose malfunctions?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...

  14. Testing of low-risk patients presenting to the emergency department with chest pain: a scientific statement from the American Heart Association.

    PubMed

    Amsterdam, Ezra A; Kirk, J Douglas; Bluemke, David A; Diercks, Deborah; Farkouh, Michael E; Garvey, J Lee; Kontos, Michael C; McCord, James; Miller, Todd D; Morise, Anthony; Newby, L Kristin; Ruberg, Frederick L; Scordo, Kristine Anne; Thompson, Paul D

    2010-10-26

    The management of low-risk patients presenting to emergency departments is a common and challenging clinical problem entailing 8 million emergency department visits annually. Although a majority of these patients do not have a life-threatening condition, the clinician must distinguish between those who require urgent treatment of a serious problem and those with more benign entities who do not require admission. Inadvertent discharge of patients with acute coronary syndrome from the emergency department is associated with increased mortality and liability, whereas inappropriate admission of patients without serious disease is neither indicated nor cost-effective. Clinical judgment and basic clinical tools (history, physical examination, and electrocardiogram) remain primary in meeting this challenge and affording early identification of low-risk patients with chest pain. Additionally, established and newer diagnostic methods have extended clinicians' diagnostic capacity in this setting. Low-risk patients presenting with chest pain are increasingly managed in chest pain units in which accelerated diagnostic protocols are performed, comprising serial electrocardiograms and cardiac injury markers to exclude acute coronary syndrome. Patients with negative findings usually complete the accelerated diagnostic protocol with a confirmatory test to exclude ischemia. This is typically an exercise treadmill test or a cardiac imaging study if the exercise treadmill test is not applicable. Rest myocardial perfusion imaging has assumed an important role in this setting. Computed tomography coronary angiography has also shown promise in this setting. A negative accelerated diagnostic protocol evaluation allows discharge, whereas patients with positive findings are admitted. This approach has been found to be safe, accurate, and cost-effective in low-risk patients presenting with chest pain.

  15. The road map towards providing a robust Raman spectroscopy-based cancer diagnostic platform and integration into clinic

    NASA Astrophysics Data System (ADS)

    Lau, Katherine; Isabelle, Martin; Lloyd, Gavin R.; Old, Oliver; Shepherd, Neil; Bell, Ian M.; Dorney, Jennifer; Lewis, Aaran; Gaifulina, Riana; Rodriguez-Justo, Manuel; Kendall, Catherine; Stone, Nicolas; Thomas, Geraint; Reece, David

    2016-03-01

    Despite the demonstrated potential as an accurate cancer diagnostic tool, Raman spectroscopy (RS) is yet to be adopted by the clinic for histopathology reviews. The Stratified Medicine through Advanced Raman Technologies (SMART) consortium has begun to address some of the hurdles in its adoption for cancer diagnosis. These hurdles include awareness and acceptance of the technology, practicality of integration into the histopathology workflow, data reproducibility and availability of transferrable models. We have formed a consortium, in joint efforts, to develop optimised protocols for tissue sample preparation, data collection and analysis. These protocols will be supported by provision of suitable hardware and software tools to allow statistically sound classification models to be built and transferred for use on different systems. In addition, we are building a validated gastrointestinal (GI) cancers model, which can be trialled as part of the histopathology workflow at hospitals, and a classification tool. At the end of the project, we aim to deliver a robust Raman based diagnostic platform to enable clinical researchers to stage cancer, define tumour margin, build cancer diagnostic models and discover novel disease bio markers.

  16. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics.

    PubMed

    Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul

    2013-07-21

    Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.

  17. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics

    PubMed Central

    Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul

    2013-01-01

    Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format. PMID:23685876

  18. Validation of consensus panel diagnosis in dementia.

    PubMed

    Gabel, Matthew J; Foster, Norman L; Heidebrink, Judith L; Higdon, Roger; Aizenstein, Howard J; Arnold, Steven E; Barbas, Nancy R; Boeve, Bradley F; Burke, James R; Clark, Christopher M; Dekosky, Steven T; Farlow, Martin R; Jagust, William J; Kawas, Claudia H; Koeppe, Robert A; Leverenz, James B; Lipton, Anne M; Peskind, Elaine R; Turner, R Scott; Womack, Kyle B; Zamrini, Edward Y

    2010-12-01

    The clinical diagnosis of dementing diseases largely depends on the subjective interpretation of patient symptoms. Consensus panels are frequently used in research to determine diagnoses when definitive pathologic findings are unavailable. Nevertheless, research on group decision making indicates that many factors can adversely affect panel performance. To determine conditions that improve consensus panel diagnosis. Comparison of neuropathologic diagnoses with individual and consensus panel diagnoses based on clinical scenarios only, fludeoxyglucose F 18 positron emission tomography images only, and scenarios plus images. Expert and trainee individual and consensus panel deliberations using a modified Delphi method in a pilot research study of the diagnostic utility of fludeoxyglucose F 18 positron emission tomography. Forty-five patients with pathologically confirmed Alzheimer disease or frontotemporal dementia. Statistical measures of diagnostic accuracy, agreement, and confidence for individual raters and panelists before and after consensus deliberations. The consensus protocol using trainees and experts surpassed the accuracy of individual expert diagnoses when clinical information elicited diverse judgments. In these situations, consensus was 3.5 times more likely to produce positive rather than negative changes in the accuracy and diagnostic certainty of individual panelists. A rule that forced group consensus was at least as accurate as majority and unanimity rules. Using a modified Delphi protocol to arrive at a consensus diagnosis is a reasonable substitute for pathologic information. This protocol improves diagnostic accuracy and certainty when panelist judgments differ and is easily adapted to other research and clinical settings while avoiding the potential pitfalls of group decision making.

  19. TMS combined with EEG in genetic generalized epilepsy: A phase II diagnostic accuracy study.

    PubMed

    Kimiskidis, Vasilios K; Tsimpiris, Alkiviadis; Ryvlin, Philippe; Kalviainen, Reetta; Koutroumanidis, Michalis; Valentin, Antonio; Laskaris, Nikolaos; Kugiumtzis, Dimitris

    2017-02-01

    (A) To develop a TMS-EEG stimulation and data analysis protocol in genetic generalized epilepsy (GGE). (B) To investigate the diagnostic accuracy of TMS-EEG in GGE. Pilot experiments resulted in the development and optimization of a paired-pulse TMS-EEG protocol at rest, during hyperventilation (HV), and post-HV combined with multi-level data analysis. This protocol was applied in 11 controls (C) and 25 GGE patients (P), further dichotomized into responders to antiepileptic drugs (R, n=13) and non-responders (n-R, n=12).Features (n=57) extracted from TMS-EEG responses after multi-level analysis were given to a feature selection scheme and a Bayesian classifier, and the accuracy of assigning participants into the classes P-C and R-nR was computed. On the basis of the optimal feature subset, the cross-validated accuracy of TMS-EEG for the classification P-C was 0.86 at rest, 0.81 during HV and 0.92 at post-HV, whereas for R-nR the corresponding figures are 0.80, 0.78 and 0.65, respectively. Applying a fusion approach on all conditions resulted in an accuracy of 0.84 for the classification P-C and 0.76 for the classification R-nR. TMS-EEG can be used for diagnostic purposes and for assessing the response to antiepileptic drugs. TMS-EEG holds significant diagnostic potential in GGE. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  20. Towards a five-minute comprehensive cardiac MR examination using highly accelerated parallel imaging with a 32-element coil array: feasibility and initial comparative evaluation.

    PubMed

    Xu, Jian; Kim, Daniel; Otazo, Ricardo; Srichai, Monvadi B; Lim, Ruth P; Axel, Leon; Mcgorty, Kelly Anne; Niendorf, Thoralf; Sodickson, Daniel K

    2013-07-01

    To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern. Copyright © 2012 Wiley Periodicals, Inc.

  1. Pastoral diagnosis: assessing the psychotheological themes of freedom and meaning.

    PubMed

    Clarke, Joseph H

    2008-01-01

    This article is an exploration of the psychological and theological themes of freedom and meaning within the world of those who experience emotional pain. The article focuses on how freedom and meaning can contribute to the development of a pastorally rigorous diagnostic protocol. It is in the examination of emotional freedom and the search for meaning that practitioners of the pastoral arts come to an understanding of the nature of suffering. The article offers an overview of the state of pastoral diagnosis highlighting and drawing from those resources that emphasize the need for pastoral psychology to construct a diagnostic protocol that is both theological and resonate with the lived experience of clients.

  2. Clinical review: Current state and future perspectives in the diagnosis of diabetes insipidus: a clinical review.

    PubMed

    Fenske, Wiebke; Allolio, Bruno

    2012-10-01

    The differential diagnosis of diabetes insipidus (DI) is often challenging but essential, because treatment may vary substantially. This article analyzes the database and performance of currently used differential diagnostic tests for DI and discusses future perspectives for diagnostic improvement. A review of electronic and print data comprising original and review articles retrieved from the PubMed or Cochrane Library database up to January 2012 was conducted. The search term "polyuria polydipsia syndrome" was cross-referenced with underlying forms of disease and associated clinical, diagnostic, and therapeutic MeSH terms. In addition, references from review articles and textbook chapters were screened for papers containing original data. Search results were narrowed to articles containing primary data with a description of criteria for the differential diagnosis of DI. Fifteen articles on differential diagnosis of DI were identified, mainly consisting of small series of patients, and mostly covering only part of the differential diagnostic spectrum of DI. Test protocols differed, and prospective validation of diagnostic criteria was consistently missing. Inconsistent data were reported on the diagnostic superiority of direct plasma arginine vasopressin determination over the indirect water deprivation test. Both test methods revealed limitations, especially in the differentiation of disorders with a milder phenotype. The available data demonstrate limitations of current biochemical tests for the differential diagnosis of DI, potentially leading to incorrect diagnosis and treatment. The newly available assay for copeptin, the C terminus of the vasopressin precursor, holds promise for a higher diagnostic specificity and simplification of the differential diagnostic protocol in DI.

  3. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    PubMed

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  4. The clinical utility and diagnostic performance of magnetic resonance imaging for identification of early and advanced knee osteoarthritis: a systematic review.

    PubMed

    Quatman, Carmen E; Hettrich, Carolyn M; Schmitt, Laura C; Spindler, Kurt P

    2011-07-01

    Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of noninvasive interventions. To systematically review the literature relative to the following questions: (1) Is magnetic resonance imaging (MRI) a valid, sensitive, specific, accurate, and reliable instrument to identify knee articular cartilage abnormalities compared with arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Systematic review. A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), SCOPUS (from 1996), and EMBASE (from 1974) databases. Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared with arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26% and 96%. Specificity and accuracy were reported between 50% and 100% and between 49% and 94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0% and 86%, 48% and 95%, and 5% and 94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed, and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Because of heterogeneity of MRI sequences, it is not possible to make definitive conclusions regarding its global clinical utility for guiding diagnosis and treatment strategies. Traumatic sports injuries to the knee may be significant precursor events to early onset of posttraumatic osteoarthritis. Magnetic resonance imaging may aid in early identification of structural injuries to articular cartilage as evidenced by articular cartilage degeneration grading.

  5. The Clinical Utility and Diagnostic Performance of MRI for Identification of Early and Advanced Knee Osteoarthritis: A Systematic Review

    PubMed Central

    Quatman, Carmen E.; Hettrich, Carolyn M.; Schmitt, Laura C.; Spindler, Kurt P.

    2013-01-01

    Background Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of non-invasive interventions. Purpose Systematically review the literature relative to the following questions: (1) Is MRI a valid, sensitive, specific, accurate and reliable instrument to identify knee articular cartilage abnormalities compared to arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Study Design Systematic Review Methods A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), and SCOPUS (from 1996) databases. Results Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared to arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26–96%. Specificity and accuracy was reported between 50–100% and 49–94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0–86%, 48–95%, and 5–94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. Conclusions There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Due to heterogeneity of MRI sequences it is not possible to make definitive conclusions regarding its global clinical utility for guiding diagnosis and treatment strategies. Clinical Relevance Traumatic sports injuries to the knee may be significant precursor events to early onset of posttraumatic osteoarthritis. MRI may aid in early identification of structural injuries to articular cartilage as evidenced by articular cartilage degeneration grading. PMID:21730207

  6. Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T.

    PubMed

    Prakkamakul, Supada; Witzel, Thomas; Huang, Susie; Boulter, Daniel; Borja, Maria J; Schaefer, Pamela; Rosen, Bruce; Heberlein, Keith; Ratai, Eva; Gonzalez, Gilberto; Rapalino, Otto

    2016-09-01

    To compare an ultrafast brain magnetic resonance imaging (MRI) protocol to the conventional protocol in motion-prone inpatient clinical settings. This retrospective study was HIPAA compliant and approved by the Institutional Review Board with waived inform consent. Fifty-nine inpatients (30 males, 29 females; mean age 55.1, range 23-93 years)who underwent 3-Tesla brain MRI using ultrafast and conventional protocols, both including five sequences, were included in the study. The total scan time for five ultrafast sequences was 4 minutes 59 seconds. The ideal conventional acquisition time was 10 minutes 32 seconds but the actual acquisition took 15-20 minutes. The average scan times for ultrafast localizers, T1-weighted, T2-weighted, fluid-attenuated inversion recovery (FLAIR), diffusion-weighted, T2*-weighted sequences were 14, 41, 62, 96, 80, 6 seconds, respectively. Two blinded neuroradiologists independently assessed three aspects: (1) image quality, (2) gray-white matter (GM-WM) differentiation, and (3) diagnostic concordance for the detection of six clinically relevant imaging findings. Wilcoxon signed-rank test was used to compare image quality and GM-WM scores. Interobserver reproducibility was calculated. The ultrafast T1-weighted sequence demonstrated significantly better image quality (P = .005) and GM-WM differentiation (P < .001) compared to the conventional sequence. There was high agreement (>85%) between both protocols for the detection of mass-like lesion, hemorrhage, diffusion restriction, WM FLAIR hyperintensities, subarachnoid FLAIR hyperintensities, and hydrocephalus. The ultrafast protocol achieved at least comparable image quality and high diagnostic concordance compared to the conventional protocol. This fast protocol can be a viable option to replace the conventional protocol in motion-prone inpatient clinical settings. Copyright © 2016 by the American Society of Neuroimaging.

  7. Preoperative magnetic resonance imaging protocol for endoscopic cranial base image-guided surgery.

    PubMed

    Grindle, Christopher R; Curry, Joseph M; Kang, Melissa D; Evans, James J; Rosen, Marc R

    2011-01-01

    Despite the increasing utilization of image-guided surgery, no radiology protocols for obtaining magnetic resonance (MR) imaging of adequate quality are available in the current literature. At our institution, more than 300 endonasal cranial base procedures including pituitary, extended pituitary, and other anterior skullbase procedures have been performed in the past 3 years. To facilitate and optimize preoperative evaluation and assessment, there was a need to develop a magnetic resonance protocol. Retrospective Technical Assessment was performed. Through a collaborative effort between the otolaryngology, neurosurgery, and neuroradiology departments at our institution, a skull base MR image-guided (IGS) protocol was developed with several ends in mind. First, it was necessary to generate diagnostic images useful for the more frequently seen pathologies to improve work flow and limit the expense and inefficiency of case specific MR studies. Second, it was necessary to generate sequences useful for IGS, preferably using sequences that best highlight that lesion. Currently, at our institution, all MR images used for IGS are obtained using this protocol as part of preoperative planning. The protocol that has been developed allows for thin cut precontrast and postcontrast axial cuts that can be used to plan intraoperative image guidance. It also obtains a thin cut T2 axial series that can be compiled separately for intraoperative imaging, or may be fused with computed tomographic images for combined modality. The outlined protocol obtains image sequences effective for diagnostic and operative purposes for image-guided surgery using both T1 and T2 sequences. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Protocol for HER2 FISH Using a Non-cross-linking, Formalin-free Tissue Fixative to Combine Advantages of Cryo-preservation and Formalin Fixation

    PubMed Central

    Loibner, Martina; Oberauner-Wappis, Lisa; Viertler, Christian; Groelz, Daniel; Zatloukal, Kurt

    2017-01-01

    Morphologic assessment of formalin-fixed, paraffin-embedded (FFPE) tissue samples has been the gold standard for cancer diagnostics for decades due to its excellent preservation of morphology. Personalized medicine increasingly provides individually adapted and targeted therapies for characterized individual diseases enabled by combined morphological and molecular analytical technologies and diagnostics. Performance of morphologic and molecular assays from the same FFPE specimen is challenging because of the negative impact of formalin due to chemical modification and cross-linking of nucleic acids and proteins. A non-cross-linking, formalin-free tissue fixative has been recently developed to fulfil both requirements, i.e., to preserve morphology like FFPE and biomolecules like cryo-preservation. Since FISH is often required in combination with histopathology and molecular diagnostics, we tested the applicability of FISH protocols on tissues treated with this new fixative. We found that formalin post-fixation of histological sections of non-cross-linking, formalin-free and paraffin-embedded (NCFPE) breast cancer tissue generated equivalent results to those with FFPE tissue in human epidermal growth factor receptor 2 (HER2) FISH analysis. This protocol describes how a FISH assay originally developed and validated for FFPE tissue can be used for NCFPE tissues by a simple post-fixation step of histological sections. PMID:29364207

  9. Upgrade to the control system of the reflectometry diagnostic of ASDEX upgrade

    NASA Astrophysics Data System (ADS)

    Graça, S.; Santos, J.; Manso, M. E.

    2004-10-01

    The broadband frequency modulation-continuous wave microwave/millimeter wave reflectometer of ASDEX upgrade tokamak (Institut für Plasma Physik (IPP), Garching, Germany) developed by Centro de Fusão Nuclear (Lisboa, Portugal) with the collaboration of IPP, is a complex system with 13 channels (O and X modes) and two types of operation modes (swept and fixed frequency). The control system that ensures remote operation of the diagnostic incorporates VME and CAMAC bus based acquisition/timing systems. Microprocessor input/output boards are used to control and monitor the microwave circuitry and associated electronic devices. The implementation of the control system is based on an object-oriented client/server model: a centralized server manages the hardware and receives input from remote clients. Communication is handled through transmission control protocol/internet protocol sockets. Here we describe recent upgrades of the control system aiming to: (i) accommodate new channels; (ii) adapt to the heterogeneity of computing platforms and operating systems; and (iii) overcome remote access restrictions. Platform and operating system independence was achieved by redesigning the graphical user interface in JAVA. As secure shell is the standard remote access protocol adopted in major fusion laboratories, secure shell tunneling was implemented to allow remote operation of the diagnostic through the existing firewalls.

  10. Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.

    PubMed

    Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni

    2014-12-01

    The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.

  11. Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality.

    PubMed

    Ippolito, Davide; Fior, Davide; Franzesi, Cammillo Talei; Riva, Luca; Casiraghi, Alessandra; Sironi, Sandro

    2017-12-01

    Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose 4 ; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.

  12. Clinical Applicability and Cutoff Values for an Unstructured Neuropsychological Assessment Protocol for Older Adults with Low Formal Education

    PubMed Central

    de Paula, Jonas Jardim; Bertola, Laiss; Ávila, Rafaela Teixeira; Moreira, Lafaiete; Coutinho, Gabriel; de Moraes, Edgar Nunes; Bicalho, Maria Aparecida Camargos; Nicolato, Rodrigo; Diniz, Breno Satler; Malloy-Diniz, Leandro Fernandes

    2013-01-01

    Background and Objectives The neuropsychological exam plays a central role in the assessment of elderly patients with cognitive complaints. It is particularly relevant to differentiate patients with mild dementia from those subjects with mild cognitive impairment. Formal education is a critical factor in neuropsychological performance; however, there are few studies that evaluated the psychometric properties, especially criterion related validity, neuropsychological tests for patients with low formal education. The present study aims to investigate the validity of an unstructured neuropsychological assessment protocol for this population and develop cutoff values for clinical use. Methods and Results A protocol composed by the Rey-Auditory Verbal Learning Test, Frontal Assessment Battery, Category and Letter Fluency, Stick Design Test, Clock Drawing Test, Digit Span, Token Test and TN-LIN was administered to 274 older adults (96 normal aging, 85 mild cognitive impairment and 93 mild Alzheimer`s disease) with predominantly low formal education. Factor analysis showed a four factor structure related to Executive Functions, Language/Semantic Memory, Episodic Memory and Visuospatial Abilities, accounting for 65% of explained variance. Most of the tests showed a good sensitivity and specificity to differentiate the diagnostic groups. The neuropsychological protocol showed a significant ecological validity as 3 of the cognitive factors explained 31% of the variance on Instrumental Activities of Daily Living. Conclusion The study presents evidence of the construct, criteria and ecological validity for this protocol. The neuropsychological tests and the proposed cutoff values might be used for the clinical assessment of older adults with low formal education. PMID:24066031

  13. Evaluating the accessibility and utility of HIV-related point-of-care diagnostics for maternal health in rural South Africa: a study protocol

    PubMed Central

    Mashamba-Thompson, T P; Drain, P K; Sartorius, B

    2016-01-01

    Introduction Poor healthcare access is a major barrier to receiving antenatal care and a cause of high maternal mortality in South Africa (SA). ‘Point-of-care’ (POC) diagnostics is a powerful emerging healthcare approach to improve healthcare access. This study focuses on evaluating the accessibility and utility of POC diagnostics for maternal health in rural SA primary healthcare (PHC) clinics in order to generate a model framework of implementation of POC diagnostics in rural South African clinics. Method and analyses We will use several research methods, including a systematic review, quasi-experiments, survey, key informant interviews and audits. We will conduct a systematic review and experimental study to determine the impact of POC diagnostics on maternal health. We will perform a cross-sectional case study of 100 randomly selected rural primary healthcare clinics in KwaZulu-Natal to measure the context and patterns of POC diagnostics access and usage by maternal health providers and patients. We will conduct interviews with relevant key stakeholders to determine the reasons for POC deficiencies regarding accessibility and utility of HIV-related POC diagnostics for maternal health. We will also conduct a vertical audit to investigate all the quality aspects of POC diagnostic services including diagnostic accuracy in a select number of clinics. On the basis of information gathered, we will propose a model framework for improved implementation of POC diagnostics in rural South African public healthcare clinics. Statistical (Stata-13) and thematic (NVIVO) data analysis will be used in this study. Ethics and dissemination The study protocol was approved by the Ethics Committee of the University of KwaZulu-Natal (BE 484/14) and the KwaZulu-Natal Department of Health based on the Helsinki Declaration (HRKM 40/15). Findings of this study will be disseminated electronically and in print. They will be presented to conferences related to HIV/AIDS, diagnostics, maternal health and strengthening of health systems. PMID:27354074

  14. Screening for plant viruses by next generation sequencing using a modified double strand RNA extraction protocol with an internal amplification control.

    PubMed

    Kesanakurti, Prasad; Belton, Mark; Saeed, Hanaa; Rast, Heidi; Boyes, Ian; Rott, Michael

    2016-10-01

    The majority of plant viruses contain RNA genomes. Detection of viral RNA genomes in infected plant material by next generation sequencing (NGS) is possible through the extraction and sequencing of total RNA, total RNA devoid of ribosomal RNA, small RNA interference (RNAi) molecules, or double stranded RNA (dsRNA). Plants do not typically produce high molecular weight dsRNA, therefore the presence of dsRNA makes it an attractive target for plant virus diagnostics. The sensitivity of NGS as a diagnostic method demands an effective dsRNA protocol that is both representative of the sample and minimizes sample cross contamination. We have developed a modified dsRNA extraction protocol that is more efficient compared to traditional protocols, requiring reduced amounts of starting material, that is less prone to sample cross contamination. This was accomplished by using bead based homogenization of plant material in closed, disposable 50ml tubes. To assess the quality of extraction, we also developed an internal control by designing a real-time (quantitative) PCR (qPCR) assay that targets endornaviruses present in Phaseolus vulgaris cultivar Black Turtle Soup (BTS). Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  15. Comparison of PCR methods for the detection of genetic variants of carp edema virus.

    PubMed

    Adamek, Mikolaj; Matras, Marek; Jung-Schroers, Verena; Teitge, Felix; Heling, Max; Bergmann, Sven M; Reichert, Michal; Way, Keith; Stone, David M; Steinhagen, Dieter

    2017-09-20

    The infection of common carp and its ornamental variety, koi, with the carp edema virus (CEV) is often associated with the occurrence of a clinical disease called 'koi sleepy disease'. The disease may lead to high mortality in both koi and common carp populations. To prevent further spread of the infection and the disease, a reliable detection method for this virus is required. However, the high genetic variability of the CEV p4a gene used for PCR-based diagnostics could be a serious obstacle for successful and reliable detection of virus infection in field samples. By analysing 39 field samples from different geographical origins obtained from koi and farmed carp and from all 3 genogroups of CEV, using several recently available PCR protocols, we investigated which of the protocols would allow the detection of CEV from all known genogroups present in samples from Central European carp or koi populations. The comparison of 5 different PCR protocols showed that the PCR assays (both end-point and quantitative) developed in the Centre for Environment, Fisheries and Aquaculture Science exhibited the highest analytical inclusivity and diagnostic sensitivity. Currently, this makes them the most suitable protocols for detecting viruses from all known CEV genogroups.

  16. Examining Effectiveness of Group Cognitive-Behavioral Therapy for Externalizing and Internalizing Disorders in Urban Schools.

    PubMed

    Eiraldi, Ricardo; Power, Thomas J; Schwartz, Billie S; Keiffer, Jackie N; McCurdy, Barry L; Mathen, Manju; Jawad, Abbas F

    2016-07-01

    This article presents outcome data of the implementation of three group cognitive-behavioral therapy (GCBT) interventions for children with externalizing behavior problems, anxiety, and depression. School counselors and graduate students co-led the groups in two low-income urban schools. Data were analyzed to assess pre-treatment to post-treatment changes in diagnostic severity level. Results of the exploratory study indicated that all three GCBT protocols were effective at reducing diagnostic severity level for children who had a primary diagnosis of an externalizing disorder, anxiety disorder, or depressive disorder at the clinical or intermediate (at-risk) level. All three GCBT protocols were implemented with relatively high levels of fidelity. Data on the effectiveness of the interventions for reducing diagnostic severity level for externalizing and internalizing spectrum disorders and for specific disorders are presented. A discussion of implementation of mental health evidence-based interventions in urban schools is provided. © The Author(s) 2016.

  17. Detection and Characterization of Viral Species/Subspecies Using Isothermal Recombinase Polymerase Amplification (RPA) Assays.

    PubMed

    Glais, Laurent; Jacquot, Emmanuel

    2015-01-01

    Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.

  18. Location of core diagnostic information across various sequences in brain MRI and implications for efficiency of MRI scanner utilization.

    PubMed

    Sharma, Aseem; Chatterjee, Arindam; Goyal, Manu; Parsons, Matthew S; Bartel, Seth

    2015-04-01

    Targeting redundancy within MRI can improve its cost-effective utilization. We sought to quantify potential redundancy in our brain MRI protocols. In this retrospective review, we aggregated 207 consecutive adults who underwent brain MRI and reviewed their medical records to document clinical indication, core diagnostic information provided by MRI, and its clinical impact. Contributory imaging abnormalities constituted positive core diagnostic information whereas absence of imaging abnormalities constituted negative core diagnostic information. The senior author selected core sequences deemed sufficient for extraction of core diagnostic information. For validating core sequences selection, four readers assessed the relative ease of extracting core diagnostic information from the core sequences. Potential redundancy was calculated by comparing the average number of core sequences to the average number of sequences obtained. Scanning had been performed using 9.4±2.8 sequences over 37.3±12.3 minutes. Core diagnostic information was deemed extractable from 2.1±1.1 core sequences, with an assumed scanning time of 8.6±4.8 minutes, reflecting a potential redundancy of 74.5%±19.1%. Potential redundancy was least in scans obtained for treatment planning (14.9%±25.7%) and highest in scans obtained for follow-up of benign diseases (81.4%±12.6%). In 97.4% of cases, all four readers considered core diagnostic information to be either easily extractable from core sequences or the ease to be equivalent to that from the entire study. With only one MRI lacking clinical impact (0.48%), overutilization did not seem to contribute to potential redundancy. High potential redundancy that can be targeted for more efficient scanner utilization exists in brain MRI protocols.

  19. Impact of point-of-care diagnostics on maternal outcomes in HIV-infected women: systematic review and meta-analysis protocol

    PubMed Central

    Mashamba-Thompson, T P; Sartorius, B; Thabane, L; Shi, C X; Drain, P K

    2016-01-01

    Introduction Studies indicate substandard diagnostic care, delayed and missed diagnosis as some of the contributing factors to maternal mortality. The clinical impact of point-of-care (POC) diagnostics has been shown in the monitoring and treatment of a variety of infectious diseases, including HIV/AIDS and tuberculosis. The objective of this systematic review is to investigate the impact of POC diagnostics on maternal outcomes for HIV-infected women. Methods We will conduct a systematic review to evaluate the impact of POC diagnostics for improving desired healthcare outcomes for HIV-infected women. The search strategy will involve electronic databases including: Cochrane Infectious Disease Group Specialised Register; Cochrane Central Register of Control Trials, published in The Cochrane Library; PubMed; EBSCOhost and LILACS. The studies will be mapped in 2 stages: stage 1 will map studies descriptively by focus and method; stage 2 will involve additional inclusion criteria, quality assessment and data extraction undertaken by 2 reviewers in parallel. Evidence will be synthesised using relevant systematic research tools: meta-analysis and subgroup analysis will be conducted using RevMan and Stata 13 will be used for meta-regressions. We will follow recommendations described in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and the Cochrane Handbook for Intervention Reviews. Ethics and dissemination We anticipate finding a large number of studies on POC diagnostic interventions on maternal outcomes in HIV-infected women, which, once summarised, will be useful to guide future diagnostic interventions. The protocol for the systematic review has been registered in PROSPERO. The study will be disseminated electronically and in print. It will also be presented to conferences related to HIV/AIDS, POC diagnostics and maternal health. Trial registration number PROSPERO CRD42014015439. PMID:26817633

  20. Hyperventilation and photic stimulation are useful additions to a placebo-based suggestive seizure induction protocol in patients with psychogenic nonepileptic seizures.

    PubMed

    Popkirov, Stoyan; Grönheit, Wenke; Wellmer, Jörg

    2015-05-01

    The early and definitive diagnosis of psychogenic nonepileptic seizures is a common challenge in epileptology practice. Suggestive seizure induction is a valuable tool to aid the differentiation between epileptic and psychogenic nonepileptic seizures, especially when long-term video-EEG monitoring is inconclusive or unavailable. In this retrospective analysis, we compared the diagnostic yield of a classical, placebo-based induction protocol with that of an extended protocol that includes hyperventilation and photic stimulation as means of suggestion while also implementing more open, standardized patient information. We investigated whether the diversification of suggestive seizure induction has an effect on diagnostic yield and whether it preempts the administration of placebo. Data from 52 patients with confirmed psychogenic nonepileptic seizures were analyzed. While suggestive seizure induction using only placebo-based suggestion provoked a typical event in 13 of 20 patients (65%), the extended protocol was positive in 27 of 34 cases (84%); this improvement was not significant (p=0.11). Noninvasive suggestion techniques accounted for 78% of inductions, avoiding placebo administration in a majority of patients. Still, placebo remains an important part of suggestive seizure induction, responsible for 22% (6 out of 27) of successful inductions using our extended protocol. Our study demonstrates that the diversification of suggestive seizure induction is feasible and beneficial for both patients and diagnosticians. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. [Polish version of the ADOS (autism diagnostic observation schedule-generic)].

    PubMed

    Chojnicka, Izabela; Płoski, Rafał

    2012-01-01

    The article presents the Polish version of the autism diagnostic observation schedule-generic (ADOS), which together with the autism diagnostic interview-revised (ADI-R) is cited as the "gold standard" for the diagnosis of autism. The ADOS is a standardised, semistructured observation protocol appropriate for children and adults of differing age and language levels. It is linked to ICD-10 and DSM-IV-TR criteria. The ADOS consists of four modules, ranging from module 1 for nonverbal individuals to module 4 for verbally fluent adults. The adequate inter-rater reliability for items has been established. The protocol has high discriminant validity and distinguishes children with pervasive developmental disorders from children, who are outside of the spectrum. Although it does not enable to distinguish individuals with pervasive developmental disorder, unspecified from individuals with childhood autism. The paper presents subsequent steps of the translation process of the original version into Polish, as well as a chosen adaptation strategy of the Polish version. The ADOS is a very useful tool both for clinical diagnosis and for the scientific purpose diagnosis. In this last case it is extremely important to use a standardised method. Until now, there was no standardised diagnostic tool for autism in Poland.

  2. Validation of the Australian diagnostic reference levels for paediatric multi detector computed tomography: a comparison of RANZCR QUDI data and subsequent NDRLS data from 2012 to 2015.

    PubMed

    Anna, Hayton; Wallace, Anthony; Thomas, Peter

    2017-03-01

    The national diagnostic reference level service (NDRLS), was launched in 2011, however no paediatric data were submitted during the first calendar year of operation. As such, Australian national diagnostic reference levels (DRLs), for paediatric multi detector computed tomography (MDCT), were established using data obtained from a Royal Australian and New Zealand College of Radiologists (RANZCR), Quality Use of Diagnostic Imaging (QUDI), study. Paediatric data were submitted to the NDRLS in 2012 through 2015. An analysis has been made of the NDRLS paediatric data using the same method as was used to analyse the QUDI data to establish the Australian national paediatric DRLs for MDCT. An analysis of the paediatric NDRLS data has also been made using the method used to calculate the Australian national adult DRLs for MDCT. A comparison between the QUDI data and subsequent NDRLS data shows the NDRLS data to be lower on average for the Head and AbdoPelvis protocol and similar for the chest protocol. Using an average of NDRLS data submitted between 2012 and 2015 implications for updated paediatric DRLS are considered.

  3. Basic haemoglobinopathy diagnostics in Dutch laboratories; providing an informative test result.

    PubMed

    Kaufmann, J O; Smit, J W; Huisman, W; Idema, R N; Bakker, E; Giordano, P C

    2013-08-01

    After a first survey in 2001, the Dutch Association of Hematological Laboratory Research (VHL) advised its members to adopt a basic protocol for haemoglobinopathy carrier detection and to provide genetic information with all positive results to allow health-care professionals to inform carriers about potential genetic risks. This article reports on the compliance with these recommendations and their consequences. Clinical chemists of all 106 Dutch laboratories were invited to answer a survey on patient population, diagnostic techniques used, (self-reported) knowledge, use and effect of the additional information. The average increase in diagnostic output was over 60% and the recommended basic protocol was applied by 65% of the laboratories. Over 84% of the laboratories reported to be aware of the additional recommendations and 77% to be using them. Most laboratories with limited diagnostic requests were still sending their cases to other laboratories and included the genetic information received from these laboratories in their diagnostic reports. The effect of information on subsequent 'family analysis' was estimated to be between 26 and 50%. The present study shows an increase in diagnostic potential for haemoglobinopathy over the last decade, especially in the larger cities. Low 'family testing' rates were mostly found in areas with lower carrier prevalence or associated with local reluctance to pass the information to carriers. In spite of a dramatic improvement, too many carriers are still not informed because of lack of awareness among health-care providers and more education is needed. © 2012 John Wiley & Sons Ltd.

  4. Influence of tilt training on activation of the autonomic nervous system in patients with vasovagal syncope.

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Halawa, Bogumił; Mazurek, Walentyna

    2006-04-01

    Tilt training is a new treatment for vasovagal syncope. Its therapeutic efficacy is thought to be the result of the desensitization of cardiopulmonary receptors, but it could be the influence of the tilt training on the activation of the autonomic nervous system as well. The study group consisted of 24 vasovagal patients (17 women and 7 men) aged 32.5 +/- 11.8 years. The diagnostic head-up tilt test was performed according to the Italian protocol with nitroglycerin if necessary. The monitoring head-up tilt test was performed according to the Westminster protocol without provocation, after 1 to 3 months of tilt training. Holter ECG recordings for HRV parameters (time and frequency domain) were obtained from selected 2-min intervals before, during and after the diagnostic and monitoring tilt test. The diagnostic test was positive in the passive phase in 6 and after provocation in 18 patients. During the training period no syncope occurred. Analysing the HRV parameters we demonstrated the following findings: I. mRR decreases immediately after assumption of a vertical position in both tests (diagnostic and monitoring) but in the diagnostic test its further decrease occurs earlier than in the monitoring test; 2. the absolute power of the HF component is greater in the early phase of tilt after tilt training than in the corresponding period in the diagnostic test. After a longer period of tilt training the activation of the sympathetic nervous system in response to the erect position is diminished.

  5. Ultrastructural characterization of the new NG97ht human-derived glioma cell line using two different electron microscopy technical procedures.

    PubMed

    Machado, Camila Maria Longo; Zorzeto, Tatiane Queiroz; Bianco, Juares E Romero; Rosa, Renata Giardini; Genari, Selma Candelaria; Joazeiro, Paulo Pinto; Verinaud, Liana

    2009-04-01

    On the basis of transmission electron microscopy observations in tumor cell lines, oncologists have made innumerous diagnostic and therapeutical progresses. Following this path, the UNICAMP immunopathologies laboratory established the NG97 cell line derived from a human astrocytoma grade III, which when injected to the athymic nude mouse flank developed a grade IV astrocytoma. In this study, we focused on ultrastructural characterization of the NG97 cells after being recovered from xenotransplant (NG97ht). These cells in culture were assayed by two different electron microscopy procedures to characterize ultrastructures related to grade IV astrocytomas and to observe their structures through cell subcultivation. Additionally, comparative morphological descriptions of different cell passages in these technical procedures could be a useful tool for improving electron microscopy cell lineage protocols. Results from many cell passage observations showed ultrastructural similarities, which suggest malignant and glioblastoma phenotypes. In the first procedure, NG97ht cells were harvested and then incorporated into agarose before subjecting them to electron microscopy protocols, whereas in the second one, monolayer cells grew first on cover slides. Comparison among protocols revealed that organelles, cytoplasmatic extensions, spatial conformation of filopodia, and cell attachment to substrate were more preserved in the second procedure. Furthermore, in this latter procedure, a unique ellipsoidal structure was observed, which was already described when dealing with gliosarcoma cell line elsewhere. Therefore, these analyses demonstrated a morphological characterization of a new NG97ht cell line using electron transmission microscopy. Moreover, it has been shown that the second procedure provides more detailed information compared with the first.

  6. Low-field and high-field magnetic resonance contrast imaging of magnetoferritin as a pathological model system of iron accumulation

    NASA Astrophysics Data System (ADS)

    Strbak, Oliver; Balejcikova, Lucia; Baciak, Ladislav; Kovac, Jozef; Masarova-Kozelova, Marta; Krafcik, Andrej; Dobrota, Dusan; Kopcansky, Peter

    2017-09-01

    Various pathological processes including neurodegenerative disorders are associated with the accumulation of iron, while it is believed that a precursor of iron accumulation is ferritin. Physiological ferritin is due to low relaxivity, which results in only weak detection by magnetic resonance imaging (MRI) techniques. On the other hand, pathological ferritin is associated with disrupted iron homeostasis and structural changes in the mineral core, and should increase the hypointensive artefacts in MRI. On the basis of recent findings in respect to the pathological ferritin structure, we prepared the magnetoferritin particles as a possible pathological ferritin model system. The particles were characterised with dynamic light scattering, as well as with superconducting quantum interference device measurements. With the help of low-field (0.2 T) and high-field (4.7 T) MRI standard T 2-weighted protocols we found that it is possible to clearly distinguish between native ferritin as a physiological model system, and magnetoferritin as a pathological model system. Surprisingly, the T 2-weighted short TI inversion recovery protocol at low-field system showed the optimum contrast differentiation. Such findings are highly promising for exploiting the use of iron accumulation as a noninvasive diagnostics tool of pathological processes, where the magnetoferritin particles could be utilised as MRI iron quantification calibration samples.

  7. Optimising magnetic resonance image quality of the ear in healthy dogs.

    PubMed

    Wolf, Davina; Lüpke, Matthias; Wefstaedt, Patrick; Klopmann, Thilo; Nolte, Ingo; Seifert, Hermann

    2011-03-01

    The aim of this study was to develop an examination protocol for magnetic resonance imaging, in order to display diagnostically important information of the canine middle and inner ear. To ensure that this protocol could also be used as a basis for determining pathological changes, the anatomical structures of the ear were presented in detail. To minimise stress through anaesthesia in live animals, preliminary examinations were carried out on four dog cadavers. During these initial examinations, three-dimensional (3D) sequences proved to be superior to two-dimensional ones. Therefore, only 3D sequences were applied for the main examinations performed on six clinically healthy Beagles. The anonymised MR images were rated by three experienced reviewers using a five-point scale. The most valuable sequence was a T2-weighted CISS sequence (TR = 16.7 ms, TE = 8.08 ms). This sequence proved to be most suitable for illustrating the inner ear structures and enabled good tissue contrasts. The sequence ranked second best was also a T2-weighted DESS sequence (TR = 19 ms, TE = 6 ms), allowing the imaging of the tympanic cavity and enabling 3D reconstruction due to its isotropic voxels. Due to low contrast and strong noise, the other sequences (TSE, FISP, MP RAGE) were not suitable for anatomical illustration of the middle and inner ear.

  8. The implementation of a new Malaria Treatment Protocol in Timor-Leste: challenges and constraints

    PubMed Central

    Martins, João Soares; Zwi, Anthony B; Hobday, Karen; Bonaparte, Fernando; Kelly, Paul M

    2012-01-01

    Background Timor-Leste changed its malaria treatment protocol in 2007, replacing the first-line for falciparum malaria from sulphadoxine-pyrimethamine to artemether-lumefantrine. This study explored the factors affecting the implementation of the revised treatment protocol, with an emphasis on identifying key constraints. Methods A mixed method approach drew on both qualitative and quantitative data. The study included data from District Health Services in seven districts, community health centres in 14 sub-districts, four hospitals, five private clinics, one private pharmacy and the country's autonomous medical store. In-depth interviews with 36 key informants, five group interviews and 15 focus group discussions were conducted. A survey was also undertaken at community health centres and hospitals to assess the availability of a physical copy of the Malaria Treatment Protocol, as well as the availability and utilization of artemether-lumefantrine and sulphadoxine-pyrimethamine. Results Many factors impeded the implementation of the new malaria protocol. These included: inadequate introduction and training around the revised treatment protocol; unclear phasing out of sulphadoxine-pyrimethamine and phasing in of the revised treatment, artemether-lumefantrine, and the rapid diagnostic test (RDT); lack of supervision; lack of adherence to the revised guidelines by foreign health workers; lack of access to the new drug by the private sector; obstacles in the procurement process; and the use of trade names rather than generic drug description. Insufficient understanding of the rapid diagnostic test and the untimely supply of drugs further hampered implementation. Conclusion To effectively implement a revised malaria treatment protocol, barriers should be identified during the policy formulation process and those emerging during implementation should be recognized promptly and addressed. PMID:22460007

  9. A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin

    PubMed Central

    Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim

    2015-01-01

    Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511

  10. Evaluation of an imaging protocol using ultrasound as the primary diagnostic modality in pediatric patients with superficial soft tissue infections of the face and neck.

    PubMed

    Sethia, Rishabh; Mahida, Justin B; Subbarayan, Rahul A; Deans, Katherine J; Minneci, Peter C; Elmaraghy, Charles A; Essig, Garth F

    2017-05-01

    To determine the clinical impact of an initiative to use ultrasound (US) as the primary diagnostic modality for children with superficial face and neck infections versus use of computed tomography (CT). Children with a diagnosis of lymphadenitis, face or neck abscess, or face and neck cellulitis were retrospectively evaluated by the otolaryngology service. Patients were separated into two groups based on implementation of a departmental initiative to use US as the primary diagnostic modality. The pre-implementation cohort consisted of patients treated prior to the initiative (2006-2009) and the current protocol cohort consisted of patients treated after the initiative was started (2010-2013). Demographics, use of US or CT, necessity of surgical intervention, and failure of medical management were compared. Three hundred seventy three children were evaluated; 114 patients were included in the pre-implementation cohort and 259 patients were included in the current protocol cohort for comparison. Patients presenting during the current protocol period were more likely to undergo US (pre-implementation vs. current protocol, p-value) (12% vs. 49%, p < 0.0001) and less likely to undergo CT (66% vs. 41%, p < 0.0001) for their initial evaluation. There were no differences in the percentage of children who underwent prompt surgical drainage, prompt discharge without surgery, or trial inpatient observation. There were also no differences in the rate of treatment failure for patients undergoing prompt surgery or prompt discharge on antibiotics. For those patients who underwent repeat evaluation following trial medical management, US was used more frequently in the current protocol period (4% vs. 20%, p = 0.002) with no difference in CT use, selected treatment strategy, or treatment failure rates. Increased use of US on initial evaluation of children with superficial face and neck infections resulted in decreased CT utilization, without negatively impacting outcome. Decreasing pediatric radiation exposure and potential long-term effects is of primary importance. Copyright © 2017. Published by Elsevier B.V.

  11. Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients.

    PubMed

    Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert

    2018-05-01

    The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.

  12. A New On-Line Diagnosis Protocol for the SPIDER Family of Byzantine Fault Tolerant Architectures

    NASA Technical Reports Server (NTRS)

    Geser, Alfons; Miner, Paul S.

    2004-01-01

    This paper presents the formal verification of a new protocol for online distributed diagnosis for the SPIDER family of architectures. An instance of the Scalable Processor-Independent Design for Electromagnetic Resilience (SPIDER) architecture consists of a collection of processing elements communicating over a Reliable Optical Bus (ROBUS). The ROBUS is a specialized fault-tolerant device that guarantees Interactive Consistency, Distributed Diagnosis (Group Membership), and Synchronization in the presence of a bounded number of physical faults. Formal verification of the original SPIDER diagnosis protocol provided a detailed understanding that led to the discovery of a significantly more efficient protocol. The original protocol was adapted from the formally verified protocol used in the MAFT architecture. It required O(N) message exchanges per defendant to correctly diagnose failures in a system with N nodes. The new protocol achieves the same diagnostic fidelity, but only requires O(1) exchanges per defendant. This paper presents this new diagnosis protocol and a formal proof of its correctness using PVS.

  13. Diagnostic value of FDG-PET/(CT) in children with fever of unknown origin and unexplained fever during immune suppression.

    PubMed

    Blokhuis, Gijsbert J; Bleeker-Rovers, Chantal P; Diender, Marije G; Oyen, Wim J G; Draaisma, Jos M Th; de Geus-Oei, Lioe-Fee

    2014-10-01

    Fever of unknown origin (FUO) and unexplained fever during immune suppression in children are challenging medical problems. The aim of this study is to investigate the diagnostic value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and FDG-PET combined with computed tomography (FDG-PET/CT) in children with FUO and in children with unexplained fever during immune suppression. All FDG-PET/(CT) scans performed in the Radboud university medical center for the evaluation of FUO or unexplained fever during immune suppression in the last 10 years were reviewed. Results were compared with the final clinical diagnosis. FDG-PET/(CT) scans were performed in 31 children with FUO. A final diagnosis was established in 16 cases (52 %). Of the total number of scans, 32 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in these patients was 80 % and 78 %, respectively. FDG-PET/(CT) scans were performed in 12 children with unexplained fever during immune suppression. A final diagnosis was established in nine patients (75 %). Of the total number of these scans, 58 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in children with unexplained fever during immune suppression was 78 % and 67 %, respectively. FDG-PET/CT appears a valuable imaging technique in the evaluation of children with FUO and in the diagnostic process of children with unexplained fever during immune suppression. Prospective studies of FDG-PET/CT as part of a structured diagnostic protocol are warranted to assess the additional diagnostic value.

  14. Evaluation and treatment of sex addiction.

    PubMed

    Rosenberg, Kenneth Paul; Carnes, Patrick; O'Connor, Suzanne

    2014-01-01

    There have been several diagnostic labels for persistent, excessive sexual behaviors, often referred in the popular media as sex addiction. Two related diagnoses, Internet addictive disorder and hypersexual disorder, were considered for, but not included in the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders. However, most clinicians, even those trained in sexual disorders or addiction medicine, have little to no training in treating sexual compulsivity and cybersex addiction. The authors present the historical context, proposed diagnostic criteria, evaluation protocols, comorbid disorders, speculations about the neuroscience, and treatment recommendations.

  15. Cerebrospinal fluid biomarkers for the diagnosis and prognosis of Parkinson's disease: protocol for a systematic review and individual participant data meta-analysis.

    PubMed

    Eusebi, Paolo; Hansson, Oskar; Paciotti, Silvia; Orso, Massimiliano; Chiasserini, Davide; Calabresi, Paolo; Blennow, Kaj; Parnetti, Lucilla

    2017-11-22

    Idiopathic Parkinson's disease (PD) is a progressive neurodegenerative disorder related to α-synuclein misfolding and aggregation. For this reason, it belongs to the family of 'synucleinopathies', which also includes some other neurological diseases. Although imaging and ancillary investigations may be helpful in the diagnostic workup, the diagnosis of PD mostly relies on the clinician's expertise. Furthermore, there is a need today for markers that can track the disease progression in PD that might improve the evaluation of novel disease-modifying therapies. The cerebrospinal fluid (CSF) has been widely investigated with the purpose of finding useful diagnostic and prognostic biomarkers for PD. This systematic review protocol has been developed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses Protocol 2015 statement and was registered on the PROSPERO international prospective register of systematic reviews. An international collaboration will be established. We will search the Cochrane Library, Web of Science, Medline and Embase from inception, using appropriate search strategies. Individual participant data from all included studies will be merged into a single database. We will include any study assessing the diagnostic and prognostic role of CSF biomarkers in PD. To evaluate the risk of bias and applicability of primary diagnostic accuracy studies, we will use Quality Assessment of Diagnostic Accuracy Studies-2 and Quality in Prognostic Studies. We will use standard meta-analytic procedures. We will first explore the utility of each CSF biomarker in turn. For each biomarker, we will assess its diagnostic and prognostic utility by means of receiver operating characteristic analysis and regression models. We will then move towards a multivariate approach considering different panels of biomarkers. Our study will not include confidential data, and no intervention will be involved, so ethical approval is not required. The results of the study will be reported in international peer-reviewed journals. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Interpersonal Factors Are Associated with Lower Therapist Adherence in Cognitive-Behavioural Therapy for Panic Disorder.

    PubMed

    Zickgraf, Hana F; Chambless, Dianne L; McCarthy, Kevin S; Gallop, Robert; Sharpless, Brian A; Milrod, Barbara L; Barber, Jacques P

    2016-05-01

    The contributions of disorder severity, comorbidity and interpersonal variables to therapists' adherence to a cognitive-behavioural treatment (CBT) manual were tested. Thirty-eight patients received panic control therapy (PCT) for panic disorder. Trained observers watching videotapes of the sixth session of a 24-session protocol rated therapists' adherence to PCT and their use of interventions from outside the CBT model. Different observers rated patients' behavioural resistance to therapy in the same session using the client resistance code. Interview measures obtained before treatment included the Panic Disorder Severity Scale, the anxiety disorders interview schedule for Diagnostic and Statistical Manual of Mental Disorders (DSM)-IV and the structured clinical interview for DSM-IV, Axis II. Questionnaire measures were the anxiety sensitivity index at intake, and, at session 2, the therapist and client versions of the working alliance inventory-short form. The higher the patients' resistance and the more Axis II traits a patient had, the less adherent the therapist. Moreover, the more resistant the client, the more therapists resorted to interventions from outside the CBT model. Stronger therapist and patient alliance was also generally related to better adherence, but these results were somewhat inconsistent across therapists. Pretreatment disorder severity and comorbidity were not related to adherence. Interpersonal variables, particularly behavioural resistance to therapy, are related to therapists' ability to adhere to a treatment manual and to their use of interventions from outside of the CBT model. Copyright © 2015 John Wiley & Sons, Ltd. Patients' behavioural resistance to therapy may make it more difficult for cognitive-behavioural clinicians to adhere to a structured treatment protocol and more likely for them to borrow interventions from outside the CBT model. Patients' Axis II traits may make adherence to treatment CBT protocol more difficult, although whether this is true varies across therapists. Therapists' adherence to a structured protocol and borrowing from outside of the CBT model do not appear to be affected by disorder severity or Axis I comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Carbon nanotube enhanced label-free detection of microRNAs based on hairpin probe triggered solid-phase rolling-circle amplification

    NASA Astrophysics Data System (ADS)

    Tian, Qianqian; Wang, Ying; Deng, Ruijie; Lin, Lei; Liu, Yang; Li, Jinghong

    2014-12-01

    The detection of microRNAs (miRNAs) is imperative for gaining a better understanding of the functions of these biomarkers and has great potential for the early diagnosis of human disease. High sensitivity and selectivity for miRNA detection brings new challenges. Herein, an ultrasensitive protocol for electrochemical detection of miRNA is designed through carbon nanotube (CNT) enhanced label-free detection based on hairpin probe triggered solid-phase rolling-circle amplification (RCA). Traditionally, RCA, widely applied for signal enhancement in the construction of a variety of biosensors, has an intrinsic limitation of ultrasensitive detection, as it is difficult to separate the enzymes, templates, and padlock DNAs from the RCA products in the homogeneous solution. We purposely designed a solid-phase RCA strategy, using CNTs as the solid substrate, integrated with a hairpin structured probe to recognize target miRNA. In the presence of miRNA the stem-loop structure will be unfolded, triggering the CNT based RCA process. Due to the efficient blocking effect originating from the polymeric RCA products, the label-free assay of miRNA exhibits an ultrasensitive detection limit of 1.2 fM. Furthermore, the protocol possesses excellent specificity for resolving lung cancer-related let-7 family members which have only one-nucleotide variations. The high sensitivity and selectivity give the method great potential for applications in online diagnostics and in situ detection in long-term development.The detection of microRNAs (miRNAs) is imperative for gaining a better understanding of the functions of these biomarkers and has great potential for the early diagnosis of human disease. High sensitivity and selectivity for miRNA detection brings new challenges. Herein, an ultrasensitive protocol for electrochemical detection of miRNA is designed through carbon nanotube (CNT) enhanced label-free detection based on hairpin probe triggered solid-phase rolling-circle amplification (RCA). Traditionally, RCA, widely applied for signal enhancement in the construction of a variety of biosensors, has an intrinsic limitation of ultrasensitive detection, as it is difficult to separate the enzymes, templates, and padlock DNAs from the RCA products in the homogeneous solution. We purposely designed a solid-phase RCA strategy, using CNTs as the solid substrate, integrated with a hairpin structured probe to recognize target miRNA. In the presence of miRNA the stem-loop structure will be unfolded, triggering the CNT based RCA process. Due to the efficient blocking effect originating from the polymeric RCA products, the label-free assay of miRNA exhibits an ultrasensitive detection limit of 1.2 fM. Furthermore, the protocol possesses excellent specificity for resolving lung cancer-related let-7 family members which have only one-nucleotide variations. The high sensitivity and selectivity give the method great potential for applications in online diagnostics and in situ detection in long-term development. Electronic supplementary information (ESI) available: Preparation of the chemically modified multi-walled carbon nanotubes (CNTs), characterization of the CNTs and modified CNTs, preparation of the circular probe, gel electrophoresis of the RCA products, and DNA probes as noted in the text. See DOI: 10.1039/c4nr05243a

  18. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.

    PubMed

    Park, Clara; Gruber-Rouh, Tatjana; Leithner, Doris; Zierden, Amelie; Albrecht, Mortiz H; Wichmann, Julian L; Bodelle, Boris; Elsabaie, Mohamed; Scholtz, Jan-Erik; Kaup, Moritz; Vogl, Thomas J; Beeres, Martin

    2016-10-10

    Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDI vol ) values were compared. Diagnostic image quality was obtained in all patients. The median CTDI vol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.

  19. ELPIDA: a general architecture for medical imaging systems supporting telemedicine applications

    NASA Astrophysics Data System (ADS)

    Lymberopoulos, Dimitris C.; Spiropoulos, Kostas V.; Anastassopoulos, George C.; Kotsopoulos, Stavros A.; Solomou, Katerina G.

    1995-01-01

    During the next years, profound changes are expected in computer and communication technologies that will offer the medical imaging systems (MIS) industry a challenge to develop advanced telemedicine applications of high performance. Medical industry, vendors, and specialists need to agree on a universal MIS structure that will provide a stack of functions, protocols, and interfaces suitable for coordination and management of high-level image consults, reports, and review activities. Doctors and engineers have worked together to determine the types, targets, and range of such activities within a medical group working domain and to posit their impact on MIS structure. As a result, the fundamental MIS functions have been posed and organized in the form of a general MIS architecture, denoted as ELPIDA. The structure of this architecture was kept as simple as possible to allow its extension to diverse multimode operational schemes handling medical and conversational audiovisual information of different classes. The fundamentals of ELPIDA and pulmonary image diagnostic aspects have been employed for the development of a prototype MIS.

  20. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  1. Formal Logic and Flowchart for Diagnosis Validity Verification and Inclusion in Clinical Decision Support Systems

    NASA Astrophysics Data System (ADS)

    Sosa, M.; Grundel, L.; Simini, F.

    2016-04-01

    Logical reasoning is part of medical practice since its origins. Modern Medicine has included information-intensive tools to refine diagnostics and treatment protocols. We are introducing formal logic teaching in Medical School prior to Clinical Internship, to foster medical practice. Two simple examples (Acute Myocardial Infarction and Diabetes Mellitus) are given in terms of formal logic expression and truth tables. Flowcharts of both diagnostic processes help understand the procedures and to validate them logically. The particularity of medical information is that it is often accompanied by “missing data” which suggests to adapt formal logic to a “three state” logic in the future. Medical Education must include formal logic to understand complex protocols and best practices, prone to mutual interactions.

  2. Theranostic barcoded nanoparticles for personalized cancer medicine

    PubMed Central

    Yaari, Zvi; da Silva, Dana; Zinger, Assaf; Goldman, Evgeniya; Kajal, Ashima; Tshuva, Rafi; Barak, Efrat; Dahan, Nitsan; Hershkovitz, Dov; Goldfeder, Mor; Roitman, Janna Shainsky; Schroeder, Avi

    2016-01-01

    Personalized medicine promises to revolutionize cancer therapy by matching the most effective treatment to the individual patient. Using a nanoparticle-based system, we predict the therapeutic potency of anticancer medicines in a personalized manner. We carry out the diagnostic stage through a multidrug screen performed inside the tumour, extracting drug activity information with single cell sensitivity. By using 100 nm liposomes, loaded with various cancer drugs and corresponding synthetic DNA barcodes, we find a correlation between the cell viability and the drug it was exposed to, according to the matching barcodes. Based on this screen, we devise a treatment protocol for mice bearing triple-negative breast-cancer tumours, and its results confirm the diagnostic prediction. We show that the use of nanotechnology in cancer care is effective for generating personalized treatment protocols. PMID:27830705

  3. A low-dose, dual-phase cardiovascular CT protocol to assess left atrial appendage anatomy and exclude thrombus prior to left atrial intervention.

    PubMed

    Lazoura, Olga; Ismail, Tevfik F; Pavitt, Christopher; Lindsay, Alistair; Sriharan, Mona; Rubens, Michael; Padley, Simon; Duncan, Alison; Wong, Tom; Nicol, Edward

    2016-02-01

    Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.

  4. Feasibility and Safety of Evaluating Patients with Prior Coronary Artery Disease Using an Accelerated Diagnostic Algorithm in a Chest Pain Unit

    PubMed Central

    Goldkorn, Ronen; Goitein, Orly; Ben-Zekery, Sagit; Shlomo, Nir; Narodetsky, Michael; Livne, Moran; Sabbag, Avi; Asher, Elad; Matetzky, Shlomi

    2016-01-01

    An accelerated diagnostic protocol for evaluating low-risk patients with acute chest pain in a cardiologist-based chest pain unit (CPU) is widely employed today. However, limited data exist regarding the feasibility of such an algorithm for patients with a history of prior coronary artery disease (CAD). The aim of the current study was to assess the feasibility and safety of evaluating patients with a history of prior CAD using an accelerated diagnostic protocol. We evaluated 1,220 consecutive patients presenting with acute chest pain and hospitalized in our CPU. Patients were stratified according to whether they had a history of prior CAD or not. The primary composite outcome was defined as a composite of readmission due to chest pain, acute coronary syndrome, coronary revascularization, or death during a 60-day follow-up period. Overall, 268 (22%) patients had a history of prior CAD. Non-invasive evaluation was performed in 1,112 (91%) patients. While patients with a history of prior CAD had more comorbidities, the two study groups were similar regarding hospitalization rates (9% vs. 13%, p = 0.08), coronary angiography (13% vs. 11%, p = 0.41), and revascularization (6.5% vs. 5.7%, p = 0.8) performed during CPU evaluation. At 60-days the primary endpoint was observed in 12 (1.6%) and 6 (3.2%) patients without and with a history of prior CAD, respectively (p = 0.836). No mortalities were recorded. To conclude, Patients with a history of prior CAD can be expeditiously and safely evaluated using an accelerated diagnostic protocol in a CPU with outcomes not differing from patients without such a history. PMID:27669521

  5. Internet-Based Cervical Cytology Screening Program

    DTIC Science & Technology

    2005-04-01

    and Second Trials of Each Pathologist. * Reference diagnostic category: NEG, ASCUS , LSIL > HSIL Pathologist 1 Interpretation. Negative or LSIL 24 (22...Principal Investigator: David C. Wdlbbur, M.D. Description of Subject Population: Women above the age of l18 years having Pap tests performe PURPOSE We...Subject Population: Women above the age of 18 years having Pay tests performed IRB Protocol Number: 2003P-001658 Sponsor Protocol Number: n/a Consent Form

  6. Diagnosis of Arrhythmogenic Right Ventricular Cardiomyopathy: Progress and Pitfalls.

    PubMed

    Oomen, Ad W G J; Semsarian, Christopher; Puranik, Rajesh; Sy, Raymond W

    2018-04-04

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy that predominantly affects the right ventricle. With a prevalence in the range of 1:5000 to 1:2000 persons, ARVC is one of the leading causes of sudden cardiac death in young people and in athletes. Although early detection and treatment is important, the diagnosis of ARVC remains challenging. There is no single pathognomonic diagnostic finding in ARVC; rather, current international task force criteria specify diagnostic major and minor criteria in six categories: right ventricular imaging (including echocardiography and cardiac magnetic resonance imaging (MRI)), histology, repolarisation abnormalities, depolarisation and conduction abnormalities, arrhythmias and family history (including genetic testing). Combining findings from differing diagnostic modalities can establish a "definite", "borderline" or "possible" diagnosis of ARVC. However, there are limitations inherent in the current task force criteria, including the lack of specificity for ARVC; future iterations may be improved, for example, by enhanced imaging protocols able to detect subtle changes in the structure and function of the right ventricle, incorporation of electro-anatomical data, response to adrenergic challenge, and validated criteria for interpreting genetic variants. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Diagnostic reasoning strategies and diagnostic success.

    PubMed

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  8. Should the diagnostic and therapeutic protocols for adrenal incidentalomas be changed?

    PubMed

    Mateo-Gavira, Isabel; Vilchez-López, Francisco Javier; Larrán-Escandón, Laura; Ojeda-Schuldt, María Belén; Tinoco, Cristina López; Aguilar-Diosdado, Manuel

    2015-01-01

    The prevalence of adrenal incidentalomas is increasing with the aging of the population and the use of high resolution imaging technics. Current protocols propose a comprehensive monitoring of their functional and morphological state, but with no conclusive clinical evidence that endorses it. Retrospective study of 96 patients diagnosed with adrenal incidentaloma between 2008 and 2012. We evaluated clinical, functional and imaging at baseline and during follow-up. Initially, 9 cases were surgically removed: 4 due to hyperfunction (2 Cushing syndromes and 2 pheochromocytomas) and 5 due to size larger than 4cm. During follow-up one case of pheochromocytoma was diagnosed and another grew more than 1cm, needing surgery. In 98.86% of nonfunctional and benign lesions, there was no functional and/or morphological changes in the final evaluation. The results of our study challenge the validity of current diagnostic-therapeutic protocols of incidentalomas, which should be reassessed in prospective studies taking into account efficiency characteristics. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Paracoccidioidomycosis vaccine

    PubMed Central

    Travassos, Luiz R.; Taborda, Carlos P.

    2012-01-01

    Paracoccidioidomycosis is a granulomatous pulmonary infection that is generally controlled by chemotherapy. The efficacy of treatment, however, is limited by the status of the host immune response. The inhibition of a Th-2 immunity or the stimulation of Th-1 cytokines generally increases the efficacy of antifungal drugs.1 This has been achieved by immunization with an internal peptide of the major diagnostic antigen gp43 of Paracoccidioides brasiliensis. Peptide 10 (QTLIAIHTLAIRYAN) elicits an IFN-γ rich Th-1 immune response that protects against experimental intratracheal infection by this fungus. The combination of chemotherapy with P10 immunization showed additive protective effect even after 30 d of infection or in anergic mice, rendering in general, increased production of IL-12 and IFN-γ and reduction of IL-4 and IL-10. Immunotherapy with P10 even in the absence of simultaneous chemotherapy has been effective using various protocols, adjuvants, nanoparticles, P10-primed dendritic cells, and especially a combination of plasmids encoding the P10 minigene and IL-12. Gene therapy, in a long-term infection protocol succeeded in the virtual elimination of the fungus, preserving the lung structure, free from immunopathological side effects. PMID:22894948

  10. Embedded controller for GEM detector readout system

    NASA Astrophysics Data System (ADS)

    Zabołotny, Wojciech M.; Byszuk, Adrian; Chernyshova, Maryna; Cieszewski, Radosław; Czarski, Tomasz; Dominik, Wojciech; Jakubowska, Katarzyna L.; Kasprowicz, Grzegorz; Poźniak, Krzysztof; Rzadkiewicz, Jacek; Scholz, Marek

    2013-10-01

    This paper describes the embedded controller used for the multichannel readout system for the GEM detector. The controller is based on the embedded Mini ITX mainboard, running the GNU/Linux operating system. The controller offers two interfaces to communicate with the FPGA based readout system. FPGA configuration and diagnostics is controlled via low speed USB based interface, while high-speed setup of the readout parameters and reception of the measured data is handled by the PCI Express (PCIe) interface. Hardware access is synchronized by the dedicated server written in C. Multiple clients may connect to this server via TCP/IP network, and different priority is assigned to individual clients. Specialized protocols have been implemented both for low level access on register level and for high level access with transfer of structured data with "msgpack" protocol. High level functionalities have been split between multiple TCP/IP servers for parallel operation. Status of the system may be checked, and basic maintenance may be performed via web interface, while the expert access is possible via SSH server. System was designed with reliability and flexibility in mind.

  11. Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol.

    PubMed

    Gomes, Mafalda; Matias, Alexandra; Macedo, Filipe

    2015-12-01

    Every day, medical practitioners face the dilemma of exposing pregnant or possibly pregnant patients to radiation from diagnostic examinations. Both doctors and patients often have questions about the risks of radiation. The most vulnerable period is between the 8th and 15th weeks of gestation. Deterministic effects like pregnancy loss, congenital malformations, growth retardation and neurobehavioral abnormalities have threshold doses above 100-200 mGy. The risk is considered negligible at 50 mGy and in reality no diagnostic examination exceeds this limit. The risk of carcinogenesis is slightly higher than in the general population. Intravenous iodinated contrast is discouraged, except in highly selected patients. Considering all the possible noxious effects of radiation exposure, measures to diminish radiation are essential and affect the fetal outcome. Nonionizing procedures should be considered whenever possible and every radiology center should have its own data analysis on fetal radiation exposure. In this review, we analyze existing literature on fetal risks due to radiation exposure, producing a clinical protocol to guide safe radiation use in a clinical setting.

  12. Diagnostic performance of a streamlined 18F-choline PET-CT protocol for the detection of prostate carcinoma recurrence in combination with appropriate-use criteria.

    PubMed

    Frood, R; Baren, J; McDermott, G; Bottomley, D; Patel, C; Scarsbrook, A

    2018-04-30

    To evaluate the efficacy of single time-point half-body (skull base to thighs) fluorine-18 choline positron emission tomography-computed tomography (PET-CT) compared to a triple-phase acquisition protocol in the detection of prostate carcinoma recurrence. Consecutive choline PET-CT studies performed at a single tertiary referral centre in patients with biochemical recurrence of prostate carcinoma between September 2012 and March 2017 were reviewed retrospectively. The indication for the study, imaging protocol used, imaging findings, whether management was influenced by the PET-CT, and subsequent patient outcome were recorded. Ninety-one examinations were performed during the study period; 42 were carried out using a triple-phase protocol (dynamic pelvic imaging for 20 minutes after tracer injection, half-body acquisition at 60 minutes and delayed pelvic scan at 90 minutes) between 2012 and August 2015. Subsequently following interim review of diagnostic performance, a streamlined protocol and appropriate-use criteria were introduced. Forty-nine examinations were carried out using the single-phase protocol between 2015 and 2017. Twenty-nine (69%) of the triple-phase studies were positive for recurrence compared to 38 (78%) of the single-phase studies. Only one patient who had a single-phase study would have benefited from a dynamic acquisition, they have required no further treatment or imaging and are currently under prostate-specific antigen (PSA) surveillance. Choline PET-CT remains a useful tool for the detection of prostate recurrence when used in combination with appropriate-use criteria. Removal of dynamic and delayed acquisition phases reduces study time without adversely affecting accuracy. Benefits include shorter imaging time which improves patient comfort, reduced cost, and improved scanner efficiency. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Adherence to, and outcomes of, a galactomannan screening protocol in high-risk hematology patients.

    PubMed

    Harricharan, S; Biederman, K; Bombassaro, A M; Lazo-Langner, A; Elsayed, S; Fulford, A; Delport, J A; Xenocostas, A

    2018-04-01

    A twice-weekly galactomannan (gm) screening protocol was implemented in high-risk hematology inpatients. Study objectives were to determine adherence to the protocol, use of selected resources, and patient outcomes. This retrospective cohort study compared outcomes of interest before and after implementation of gm screening. Adults undergoing matched related allogeneic hematopoietic stem-cell transplantation or induction chemotherapy for acute leukemia were eligible. Patients could be enrolled more than once and were evaluated as episodes. Adherence to the gm protocol was assessed in post-implementation episodes. Use of broad-spectrum antifungals (bsafs), consultations (infectious diseases, respirology), and diagnostic procedures (computed tomography imaging, bronchoalveolar lavage) were compared between phases, as were the patient outcomes of all-cause mortality and clinical success (alive and not taking a bsaf). Of 182 episodes consecutively screened, 70 per phase were enrolled. Clinical characteristics and duration of assessment were similar for the phases. Full or partial adherence to the protocol was observed in 61 post-implementation episodes (87%), with full adherence in 40 episodes (57%). More episodes in the pre-implementation phase than in the post-implementation phase involved receipt of bsafs, consultations, and diagnostics (27% vs. 7%, p = 0.02; 46% vs. 26%, p = 0.014; and 46% vs. 31%, p = 0.083 respectively). Although mortality was similar in the two phases, clinical success at the final assessment was observed in fewer pre-implementation than post-implementation episodes (79% vs. 98%, p < 0.001). Implementation of a gm screening protocol was feasible and associated with significantly fewer episodes involving receipt of bsafs and consultations, and with significantly more episodes showing clinical success.

  14. Advances in molecular-based diagnostics in meeting crop biosecurity and phytosanitary issues.

    PubMed

    Schaad, Norman W; Frederick, Reid D; Shaw, Joe; Schneider, William L; Hickson, Robert; Petrillo, Michael D; Luster, Douglas G

    2003-01-01

    Awareness of crop biosecurity and phytosanitation has been heightened since 9/11 and the unresolved anthrax releases in October 2001. Crops are highly vulnerable to accidental or deliberate introductions of crop pathogens from outside U.S. borders. Strategic thinking about protection against deliberate or accidental release of a plant pathogen is an urgent priority. Rapid detection will be the key to success. This review summarizes recent progress in the development of rapid real-time PCR protocols and evaluates their effectiveness in a proposed nationwide network of diagnostic laboratories that will facilitate rapid diagnostics and improved communication.

  15. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography

    NASA Astrophysics Data System (ADS)

    Alshipli, Marwan; Kabir, Norlaili A.

    2017-05-01

    Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.

  16. CT-angiography protocol with low dose radiation and low volume contrast medium for non-cardiac chest pain

    PubMed Central

    Ozkurt, Huseyin; Tokgoz, Safiye; Karabay, Esra; Ucan, Berna; Akdogan, Melek Pala; Basak, Muzaffer

    2014-01-01

    Aim To evaluate the diagnostic quality of a new multiple detector-row computed tomography angiography (MDCT-A) protocol using low dose radiation and low volume contrast medium techniques for evaluation of non-cardiac chest pain. Methods Forty-five consecutive patients with clinically suspected noncardiac chest pain and requiring contrast-enhanced chest computed tomography (CT) were examined. The patients were assigned to the protocol, with 80 kilovolt (peak) (kV[p]) and 150 effective milliampere-second (eff mA-s). In our study group, 40 mL of low osmolar contrast material was administered at 3.0 mL/s. Results In the study group, four patients with pulmonary embolism, four with pleural effusion, two with ascending aortic aneurysm and eight patients with pneumonic consolidation were detected. The mean attenuation of the pulmonary truncus and ascendant aortic locations was considered 264±44 and 249±51 HU, respectively. The mean effective radiation dose was 0.83 mSv for MDCT-A. Conclusions Pulmonary artery and the aorta scanning simultaneously was significantly reduced radiation exposure with the mentioned dose saving technique. Additionally, injection of low volume (40 cc) contrast material may reduce the risk of contrast induced nephropathy, therefore, facilitate the diagnostic approach. This technique can be applied to all cases and particularly patients at high risk of contrast induced nephropathy due to its similar diagnostic quality with a low dose and high levels of arteriovenous enhancement simultaneously. PMID:25392818

  17. Large-scale production and isolation of Candida biofilm extracellular matrix.

    PubMed

    Zarnowski, Robert; Sanchez, Hiram; Andes, David R

    2016-12-01

    The extracellular matrix of biofilm is unique to the biofilm lifestyle, and it has key roles in community survival. A complete understanding of the biochemical nature of the matrix is integral to the understanding of the roles of matrix components. This knowledge is a first step toward the development of novel therapeutics and diagnostics to address persistent biofilm infections. Many of the assay methods needed for refined matrix composition analysis require milligram amounts of material that is separated from the cellular components of these complex communities. The protocol described here explains the large-scale production and isolation of the Candida biofilm extracellular matrix. To our knowledge, the proposed procedure is the only currently available approach in the field that yields milligram amounts of biofilm matrix. This procedure first requires biofilms to be seeded in large-surface-area roller bottles, followed by cell adhesion and biofilm maturation during continuous movement of the medium across the surface of the rotating bottle. The formed matrix is then separated from the entire biomass using sonication, which efficiently removes the matrix without perturbing the fungal cell wall. Subsequent filtration, dialysis and lyophilization steps result in a purified matrix product sufficient for biochemical, structural and functional assays. The overall protocol takes ∼11 d to complete. This protocol has been used for Candida species, but, using the troubleshooting guide provided, it could be adapted for other fungi or bacteria.

  18. A universal protocol to generate consensus level genome sequences for foot-and-mouth disease virus and other positive-sense polyadenylated RNA viruses using the Illumina MiSeq.

    PubMed

    Logan, Grace; Freimanis, Graham L; King, David J; Valdazo-González, Begoña; Bachanek-Bankowska, Katarzyna; Sanderson, Nicholas D; Knowles, Nick J; King, Donald P; Cottam, Eleanor M

    2014-09-30

    Next-Generation Sequencing (NGS) is revolutionizing molecular epidemiology by providing new approaches to undertake whole genome sequencing (WGS) in diagnostic settings for a variety of human and veterinary pathogens. Previous sequencing protocols have been subject to biases such as those encountered during PCR amplification and cell culture, or are restricted by the need for large quantities of starting material. We describe here a simple and robust methodology for the generation of whole genome sequences on the Illumina MiSeq. This protocol is specific for foot-and-mouth disease virus (FMDV) or other polyadenylated RNA viruses and circumvents both the use of PCR and the requirement for large amounts of initial template. The protocol was successfully validated using five FMDV positive clinical samples from the 2001 epidemic in the United Kingdom, as well as a panel of representative viruses from all seven serotypes. In addition, this protocol was successfully used to recover 94% of an FMDV genome that had previously been identified as cell culture negative. Genome sequences from three other non-FMDV polyadenylated RNA viruses (EMCV, ERAV, VESV) were also obtained with minor protocol amendments. We calculated that a minimum coverage depth of 22 reads was required to produce an accurate consensus sequence for FMDV O. This was achieved in 5 FMDV/O/UKG isolates and the type O FMDV from the serotype panel with the exception of the 5' genomic termini and area immediately flanking the poly(C) region. We have developed a universal WGS method for FMDV and other polyadenylated RNA viruses. This method works successfully from a limited quantity of starting material and eliminates the requirement for genome-specific PCR amplification. This protocol has the potential to generate consensus-level sequences within a routine high-throughput diagnostic environment.

  19. A vascular laboratory protocol for improving and managing after-hours suspected acute deep venous thrombosis.

    PubMed

    Martin, Angela H; Eckert, George; Lemmon, Gary W; Sawchuk, Alan; Dalsing, Michael C

    2014-04-01

    This study reviews the clinical and workforce impact of a suggested protocol designed for the management of suspected acute deep venous thrombosis (DVT) in patients seen after standard vascular laboratory business hours. The protocol included the use of Wells score, D-dimer and a single dose of therapeutic anticoagulant to defer venous duplex ultrasound (VDU) testing until routine business hours unless contraindicated. Information was collected on medical history, physical exam and the timing of any diagnostic studies and treatment provided. Over 15% of studies done after-hours were deemed unnecessary by our protocol and in every individual the results were negative for an acute DVT. There were no adverse events from a one-time dose of anticoagulant. Limiting emergency VDU coverage to evaluate for acute DVT based on a management protocol can eliminate unnecessary after-hours VDU testing without having a negative impact on patient care.

  20. Sensitive Troponin I and Stress Testing in the Emergency Department for the Early Management of Chest Pain Using 2-Hour Protocol.

    PubMed

    Dadkhah, Shahriar; Almuwaqqat, Zakaria; Sulaiman, Samian; Husein, Husein; Nguyen, Quang; Ali, Saad; Taskesen, Tuncay

    2017-09-01

    Despite improvements in identifying high-risk patients with non-ST segment ACS (acute coronary syndrome), low risk patients presenting with atypical chest pain and non-diagnostic Electrocardiogram (ECG) continued to undergo unnecessary admissions and testing. Since 1992, our chest pain protocol included using 4-hour serial biomarkers from ED admission in combination with stress testing to evaluate these patients. Our study aimed at determining whether a new accelerated diagnostic protocol using sensitive cardiac troponin I (cTnI) 2 hours after admission to the ED followed by stress testing is safe and effective in emergency settings, allowing for appropriate triage, earlier discharge and reducing costs. We conducted a single center randomized trial at Presence St. Francis Hospital Chest pain center in Evanston, Illinois enrolling sixty-four consecutive patients with atypical chest pain and non-diagnostic ECG, participants were randomized to accelerated 2 hrs protocol or our pre-existing 4-hrs protocol. Sixty patients completed the protocol and were randomized to either a 2-hour (29 patients) or 4-hour protocol using both I-STAT and PATHFAST cTnI (31 Patients). Troponin I was evaluated at 0 and at 2 hours from ED presentation with and additional draw for patients in the 4-hour rule out-group. Patients with normal serial biomarkers were then evaluated with stress testing and qualified for earlier discharge if the stress test was negative, while those with a positive biomarker at any time were admitted. Thirty-six patients had exercise treadmill stress test and 24 patients had either nuclear or Echo stress test. Fifty-three patients had a normal stress test and were discharged home. One patient in the 4-hour group with normal serial troponins developed ventricular tachycardia/fibrillation during the recovery period of a regular stress test. Six patients had a positive PATHFAST cTnI and a normal I-STAT cTnI at 2-hours. Two out of these six patients evaluated by coronary angiography. One patient had severe tortuous coronaries but no significant obstructive lesion and one had a severe CAD who needed Coronary artery bypass grafting (CABG). Three of the six patients had a normal stress test and one patient decided to leave without further testing. None of the patients with a normal stress test had a major cardiac event or adverse cardiac outcome at six-month follow up. This study demonstrates that the 2 hours accelerated protocol using high sensitivity Troponin assay at 0 and 2 hours with comprehensive clinical evaluation and ECG followed by stress testing might be successful in identifying low-risk patient population who may benefit from early discharge from ED reducing associated costs and length of stay.

  1. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    PubMed

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  2. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia

    PubMed Central

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-01-01

    Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612

  3. Bedside diagnosis of dysphagia: a systematic review.

    PubMed

    O'Horo, John C; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-04-01

    Dysphagia is associated with aspiration, pneumonia, and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. We conducted a comprehensive search of 7 databases, including MEDLINE, Embase, and Scopus, from each database's earliest inception through June 9, 2014. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study or flexible endoscopic evaluation of swallowing with sensory testing) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design, and prediction of aspiration. The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and 1 description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in poststroke adults, limiting the generalizability of results. No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. © 2015 Society of Hospital Medicine.

  4. Two different PCR approaches for universal diagnosis of brown rot and identification of Monilinia spp. in stone fruit trees.

    PubMed

    Gell, I; Cubero, J; Melgarejo, P

    2007-12-01

    To design a protocol for the universal diagnosis of brown rot by polymerase chain reaction (PCR) in plant material and subsequently Monilinia spp. identification. Primers for discrimination of Monilinia spp. from other fungal genera by PCR were designed following a ribosomal DNA analysis. Discrimination among species of Monilinia was subsequently achieved by developing primers using SCAR (Sequence Characterised Amplified Region) markers obtained after a random amplified polymorphic DNA study. In addition, an internal control (IC) based on the utilization of a mimic plasmid was designed to be used in the diagnostic protocol of brown rot to recognize false negatives due to the inhibition of PCR. The four sets of primers designed allowed detection and discrimination of all Monilinia spp. causing brown rot in fruit trees. Addition of an IC in each PCR reaction performed increased the reliability of the diagnostic protocol. The detection protocol presented here, that combined a set of universal primers and the inclusion of the plasmid pGMON as an IC for diagnosis of all Monilinia spp., and three sets of primers to discriminate the most important species of Monilinia, could be an useful and valuable tool for epidemiological studies. The method developed could be used in programmes to avoid the spread and introduction of this serious disease in new areas.

  5. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review.

    PubMed

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2015-04-02

    Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may provide a more accurate and immediate diagnosis of implant-root contact (target condition) than radiographic imaging (reference standard). An accurate index test could reduce or eliminate X-ray exposure. These issues, the common use of OMIs, the high prevalence of the target condition, and because most OMIs are placed between roots warrant a systematic review. We will assess 1) the diagnostic accuracy and the adverse effects of the index test, 2) whether OMIs with root contact have higher insertion torque values than those without, and 3) whether intermediate torque values have clinical diagnostic utility. The Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) 2015 statement was used as a the guideline for reporting this protocol. Inserting implants deliberately into dental roots of human participants would not be approved by ethical review boards and adverse effects of interventions are generally underreported. We will therefore apply broad spectrum eligibility criteria, which will include clinical, animal and cadaver models. Not including these models could slow down knowledge translation. Both randomized and non-randomized research studies will be included. Comparisons of interest and subgroups are pre-specified. We will conduct searches in MEDLINE and more than 40 other electronic databases. We will search the grey literature and reference lists and hand-search ten journals. All methodological procedures will be conducted by three reviewers. Study selection, data extraction and analyses, and protocols for contacting authors and resolving conflicts between reviewers are described. Designed specific risk of bias tools will be tailored to the research question. Different research models will be analysed separately. Parameters for exploring statistical heterogeneity and conducting meta-analyses are pre-specified. The quality of evidence for outcomes will be assessed through the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The findings of this systematic review will be useful for patients, clinicians, researchers, guideline developers, policymakers, and surgical companies.

  6. Translational Neuromodulation: Approximating Human Transcranial Magnetic Stimulation Protocols In Rats

    PubMed Central

    Vahabzadeh-Hagh, Andrew M.; Muller, Paul A.; Gersner, Roman; Zangen, Abraham; Rotenberg, Alexander

    2015-01-01

    Objective Transcranial magnetic stimulation (TMS) is a well-established clinical protocol with numerous potential therapeutic and diagnostic applications. Yet, much work remains in the elucidation of TMS mechanisms, optimization of protocols, and in development of novel therapeutic applications. As with many technologies, the key to these issues lies in the proper experimentation and translation of TMS methods to animal models, among which rat models have proven popular. A significant increase in the number of rat TMS publications has necessitated analysis of their relevance to human work. We therefore review the essential principles necessary for the approximation of human TMS protocols in rats as well as specific methods that addressed these issues in published studies. Materials and Methods We performed an English language literature search combined with our own experience and data. We address issues that we see as important in the translation of human TMS methods to rat models and provide a summary of key accomplishments in these areas. Results An extensive literature review illustrated the growth of rodent TMS studies in recent years. Current advances in the translation of single, paired-pulse, and repetitive stimulation paradigms to rodent models are presented. The importance of TMS in the generation of data for preclinical trials is also highlighted. Conclusions Rat TMS has several limitations when considering parallels between animal and human stimulation. However, it has proven to be a useful tool in the field of translational brain stimulation and will likely continue to aid in the design and implementation of stimulation protocols for therapeutic and diagnostic applications. PMID:22780329

  7. Influence of LCD color reproduction accuracy on observer performance using virtual pathology slides

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Silverstein, Louis D.; Hashmi, Syed F.; Graham, Anna R.; Weinstein, Ronald S.; Roehrig, Hans

    2012-02-01

    The use of color LCDs in medical imaging is growing as more clinical specialties use digital images as a resource in diagnosis and treatment decisions. Telemedicine applications such as telepathology, teledermatology and teleophthalmology rely heavily on color images. However, standard methods for calibrating, characterizing and profiling color displays do not exist, resulting in inconsistent presentation. To address this, we developed a calibration, characterization and profiling protocol for color-critical medical imaging applications. Physical characterization of displays calibrated with and without the protocol revealed high color reproduction accuracy with the protocol. The present study assessed the impact of this protocol on observer performance. A set of 250 breast biopsy virtual slide regions of interest (half malignant, half benign) were shown to 6 pathologists, once using the calibration protocol and once using the same display in its "native" off-the-shelf uncalibrated state. Diagnostic accuracy and time to render a decision were measured. In terms of ROC performance, Az (area under the curve) calibrated = 0.8640; uncalibrated = 0.8558. No statistically significant difference (p = 0.2719) was observed. In terms of interpretation speed, mean calibrated = 4.895 sec, mean uncalibrated = 6.304 sec which is statistically significant (p = 0.0460). Early results suggest a slight advantage diagnostically for a properly calibrated and color-managed display and a significant potential advantage in terms of improved workflow. Future work should be conducted using different types of color images that may be more dependent on accurate color rendering and a wider range of LCDs with varying characteristics.

  8. Electromagnetic Analysis of ITER Diagnostic Equatorial Port Plugs During Plasma Disruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Y. Zhai, R. Feder, A. Brooks, M. Ulrickson, C.S. Pitcher and G.D. Loesser

    2012-08-27

    ITER diagnostic port plugs perform many functionsincluding structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs), Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less

  9. Pre-cut Filter Paper for Detecting Anti-Japanese Encephalitis Virus IgM from Dried Cerebrospinal Fluid Spots

    PubMed Central

    Bharucha, Tehmina; Chanthongthip, Anisone; Phuangpanom, Soumphou; Phonemixay, Ooyanong; Sengvilaipaseuth, Onanong; Vongsouvath, Manivanh; Lee, Sue; Newton, Paul N.; Dubot-Pérès, Audrey

    2016-01-01

    Background The use of filter paper as a simple, inexpensive tool for storage and transportation of blood, ‘Dried Blood Spots’ or Guthrie cards, for diagnostic assays is well-established. In contrast, there are a paucity of diagnostic evaluations of dried cerebrospinal fluid (CSF) spots. These have potential applications in low-resource settings, such as Laos, where laboratory facilities for central nervous system (CNS) diagnostics are only available in Vientiane. In Laos, a major cause of CNS infection is Japanese encephalitis virus (JEV). We aimed to develop a dried CSF spot protocol and to evaluate its diagnostic performance using the World Health Organisation recommended anti-JEV IgM antibody capture enzyme-linked immunosorbent assay (JEV MAC-ELISA). Methodology and Principal Findings Sample volumes, spotting techniques and filter paper type were evaluated using a CSF-substitute of anti-JEV IgM positive serum diluted in Phosphate Buffer Solution (PBS) to end-limits of detection by JEV MAC-ELISA. A conventional protocol, involving eluting one paper punch in 200μl PBS, did not detect the end-dilution, nor did multiple punches utilising diverse spotting techniques. However, pre-cut filter paper enabled saturation with five times the volume of CSF-substitute, sufficiently improving sensitivity to detect the end-dilution. The diagnostic accuracy of this optimised protocol was compared with routine, neat CSF in a pilot, retrospective study of JEV MAC-ELISA on consecutive CSF samples, collected 2009–15, from three Lao hospitals. In comparison to neat CSF, 132 CSF samples stored as dried CSF spots for one month at 25–30°C showed 81.6% (65.7–92.3 95%CI) positive agreement, 96.8% (91.0–99.3 95%CI) negative agreement, with a kappa coefficient of 0.81 (0.70–0.92 95%CI). Conclusions/Significance The novel design of pre-cut filter paper saturated with CSF could provide a useful tool for JEV diagnostics in settings with limited laboratory access. It has the potential to improve national JEV surveillance and inform vaccination policies. The saturation of filter paper has potential use in the wider context of pathogen detection, including dried spots for detecting other analytes in CSF, and other body fluids. PMID:26986061

  10. 7T MRI in focal epilepsy with unrevealing conventional field strength imaging.

    PubMed

    De Ciantis, Alessio; Barba, Carmen; Tassi, Laura; Cosottini, Mirco; Tosetti, Michela; Costagli, Mauro; Bramerio, Manuela; Bartolini, Emanuele; Biagi, Laura; Cossu, Massimo; Pelliccia, Veronica; Symms, Mark R; Guerrini, Renzo

    2016-03-01

    To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T) MRI. We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure-onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three-dimensional [3D] T1 -weighted [T1W] fast-spoiled gradient echo (FSPGR), 3D susceptibility-weighted angiography [SWAN], 3D fluid-attenuated inversion recovery [FLAIR]) and targeted imaging (2D T2*-weighted dual-echo gradient-recalled echo [GRE] and 2D gray-white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE-IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus-based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T targeted at the suspected SOZ increases the diagnostic yield. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  11. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    PubMed Central

    Pedraza, Rodrigo; Nieto, Javier; Ibarra, Sergio; Haas, Eric M.

    2014-01-01

    Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR) is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1) initial baseline phase; (2) rapid contraction phase; (3) tonic contraction and endurance phase; and (4) late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1) down-training; (2) accessory muscle isolation; (3) discrimination training; (4) muscle strengthening; (5) endurance training; and (6) electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course. PMID:25006337

  12. The Montreal Protocol for Identification of Amusia.

    PubMed

    Vuvan, D T; Paquette, S; Mignault Goulet, G; Royal, I; Felezeu, M; Peretz, I

    2018-04-01

    The Montreal Battery for the Evaluation of Amusia (MBEA; Peretz, Champod, & Hyde Annals of the New York Academy of Sciences, 999, 58-75, 2003) is an empirically grounded quantitative tool that is widely used to identify individuals with congenital amusia. The use of such a standardized measure ensures that the individuals tested will conform to a specific neuropsychological profile, allowing for comparisons across studies and research groups. Recently, a number of researchers have published credible critiques of the usefulness of the MBEA as a diagnostic tool for amusia. Here we argue that the MBEA and its online counterpart, the AMUSIA tests (Peretz et al. Music Perception, 25, 331-343, 2008), should be considered steps in a screening process for amusia, rather than standalone diagnostic tools. The goal of this article is to present, in detailed and easily replicable format, the full protocol through which congenital amusics should be identified. In providing information that has often gone unreported in published articles, we aim to clarify the strengths and limitations of the MBEA and to make recommendations for its continued use by the research community as part of the Montreal Protocol for Identification of Amusia.

  13. Chronic inflammatory demyelinating polyneuropathy: evaluation of the vestibular system with cervical and ocular vestibular evoked myogenic potentials.

    PubMed

    Magliulo, Giuseppe; Iannella, Giannicola; Manno, Alessandra; Libonati, Laura; Onesti, Emanuela; Vestri, Annarita; Fegatelli, Danilo Alunni; Angeletti, Diletta; Pace, Annalisa; Gulotta, Giampiero; Gagliardi, Silvia; Inghilleri, Maurizio

    2018-06-01

    To investigate the possibility of vestibular damage in a group of patients suffering from chronic inflammatory demyelinating polyneuropathy (CIDP) using a diagnostic protocol including the caloric test, C-VEMPs and O-VEMPs. Twenty patients suffering from CIDP (mean age 58.5 years, range 33-80 years; 4 women and 16 men) were investigated. To assess any eventual audio-vestibular involvement, all patients of the study underwent pure tone audiometry, Fitzgerald-Hallpike caloric vestibular test, C-VEMPs and O-VEMPs. In 11 patients with CIDP values of both O-VEMPs and C-VEMPs were either absent or abnormal. An absent trace at O-VEMPs testing occurred in 36% of these pathological patients, whereas an increase of n10 latency and amplitude was present in the other 64% . A specific diagnostic protocol including the caloric test, C-VEMPS, O-VEMPS, could be useful when employed for identifying vestibular damage in CIDP patients.

  14. Digitized molecular diagnostics: reading disk-based bioassays with standard computer drives.

    PubMed

    Li, Yunchao; Ou, Lily M L; Yu, Hua-Zhong

    2008-11-01

    We report herein a digital signal readout protocol for screening disk-based bioassays with standard optical drives of ordinary desktop/notebook computers. Three different types of biochemical recognition reactions (biotin-streptavidin binding, DNA hybridization, and protein-protein interaction) were performed directly on a compact disk in a line array format with the help of microfluidic channel plates. Being well-correlated with the optical darkness of the binding sites (after signal enhancement by gold nanoparticle-promoted autometallography), the reading error levels of prerecorded audio files can serve as a quantitative measure of biochemical interaction. This novel readout protocol is about 1 order of magnitude more sensitive than fluorescence labeling/scanning and has the capability of examining multiplex microassays on the same disk. Because no modification to either hardware or software is needed, it promises a platform technology for rapid, low-cost, and high-throughput point-of-care biomedical diagnostics.

  15. Abdominal symptoms during physical exercise and the role of gastrointestinal ischaemia: a study in 12 symptomatic athletes.

    PubMed

    ter Steege, Rinze W F; Geelkerken, Robert H; Huisman, Ad B; Kolkman, Jeroen J

    2012-10-01

    Gastrointestinal (GI) symptoms during exercise may be caused by GI ischaemia. The authors report their experience with the diagnostic protocol and management of athletes with symptomatic exercise-induced GI ischaemia. The value of prolonged exercise tonometry in the diagnostic protocol of these patients was evaluated. Patients referred for GI symptoms during physical exercise underwent a standardised diagnostic protocol, including prolonged exercise tonometry. Indicators of GI ischaemia, as measured by tonometry, were related to the presence of symptoms during the exercise test (S+ and S- tests) and exercise intensity. 12 athletes were specifically referred for GI symptoms during exercise (five males and seven females; median age 29 years (range 15-46 years)). Type of sport was cycling, long-distance running and triathlon. Median duration of symptoms was 32 months (range 7-240 months). Splanchnic artery stenosis was found in one athlete. GI ischaemia was found in six athletes during submaximal exercise. All athletes had gastric and jejunal ischaemia during maximum intensity exercise. No significant difference was found in gastric and jejunal Pco(2) or gradients between S+ and S- tests during any phase of the exercise protocol. In S+ tests, but not in S- tests, a significant correlation between lactate and gastric gradient was found. In S+ tests, the regression coefficients of gradients were higher than those in S- tests. Treatment advice aimed at limiting GI ischaemia were successful in reducing complaints in the majority of the athletes. GI ischaemia was present in all athletes during maximum intensity exercise and in 50% during submaximal exercise. Athletes with GI symptoms had higher gastric gradients per mmol/l increase in lactate, suggesting an increased susceptibility for the development of ischaemia during exercise. Treatment advice aimed at limiting GI ischaemia helped the majority of the referred athletes to reduce their complaints. Our results suggest an important role for GI ischaemia in the pathophysiology of their complaints.

  16. Improving statistical inference on pathogen densities estimated by quantitative molecular methods: malaria gametocytaemia as a case study.

    PubMed

    Walker, Martin; Basáñez, María-Gloria; Ouédraogo, André Lin; Hermsen, Cornelus; Bousema, Teun; Churcher, Thomas S

    2015-01-16

    Quantitative molecular methods (QMMs) such as quantitative real-time polymerase chain reaction (q-PCR), reverse-transcriptase PCR (qRT-PCR) and quantitative nucleic acid sequence-based amplification (QT-NASBA) are increasingly used to estimate pathogen density in a variety of clinical and epidemiological contexts. These methods are often classified as semi-quantitative, yet estimates of reliability or sensitivity are seldom reported. Here, a statistical framework is developed for assessing the reliability (uncertainty) of pathogen densities estimated using QMMs and the associated diagnostic sensitivity. The method is illustrated with quantification of Plasmodium falciparum gametocytaemia by QT-NASBA. The reliability of pathogen (e.g. gametocyte) densities, and the accompanying diagnostic sensitivity, estimated by two contrasting statistical calibration techniques, are compared; a traditional method and a mixed model Bayesian approach. The latter accounts for statistical dependence of QMM assays run under identical laboratory protocols and permits structural modelling of experimental measurements, allowing precision to vary with pathogen density. Traditional calibration cannot account for inter-assay variability arising from imperfect QMMs and generates estimates of pathogen density that have poor reliability, are variable among assays and inaccurately reflect diagnostic sensitivity. The Bayesian mixed model approach assimilates information from replica QMM assays, improving reliability and inter-assay homogeneity, providing an accurate appraisal of quantitative and diagnostic performance. Bayesian mixed model statistical calibration supersedes traditional techniques in the context of QMM-derived estimates of pathogen density, offering the potential to improve substantially the depth and quality of clinical and epidemiological inference for a wide variety of pathogens.

  17. Design and Implementation of Software Protocol in VAX/VMS Using Ethernet Local Area Network.

    DTIC Science & Technology

    1983-06-01

    firm hclding the trademark: INTEL Ccrporation, Santa Clara, California INTELLEC IDS Multbus DIGITAL Research, Pacific Grove, California CE/M-80...bcard NS2030 VMS device driver and N11010 diagnostic program DIGITAL Equipment Corporation, Maynard, Massachusetts V&Z-11/780 Mini computer VAX/VMS...8217 . . - - . , . editors, libary , etc.) of one node to an application process in another ncde. Such protocols may include: 1) .. 11 T f6 - allowing a process in one node to

  18. Improvement of malaria diagnostic system based on acridine orange staining.

    PubMed

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  19. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  20. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research.

    PubMed

    Waddell, Lisa A; Greig, Judy; Mascarenhas, Mariola; Harding, Shannon; Lindsay, Robbin; Ogden, Nicholas

    2016-01-01

    There has been an increasing incidence of Lyme disease (LD) in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto). There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42) and in-house developed tests used by private laboratories which have not been evaluated in the primary literature.

  1. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research

    PubMed Central

    Lindsay, Robbin; Ogden, Nicholas

    2016-01-01

    There has been an increasing incidence of Lyme disease (LD) in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto). There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42) and in-house developed tests used by private laboratories which have not been evaluated in the primary literature. PMID:28002488

  2. Cholera diagnosis in human stool and detection in water: protocol for a systematic review of available technologies.

    PubMed

    Diaconu, Karin; Falconer, Jennifer; O'May, Fiona; Jimenez, Miguel; Matragrano, Joe; Njanpop-Lafourcade, Betty; Ager, Alastair

    2018-02-20

    Cholera is a highly infectious diarrheal disease spread via fecal contamination of water and food sources; it is endemic in parts of Africa and Asia and recent outbreaks have been reported in Haiti, the Zambia and Democratic Republic of the Congo. If left untreated, the disease can be fatal in less than 24 h and result in case fatality ratios of 30-50%. Cholera disproportionately affects those living in areas with poor access to water and sanitation: the long-term public health response is focused on improving water and hygiene facilities and access. Short-term measures for infection prevention and control, and disease characterization and surveillance, are impaired by diagnostic delays: culture methods are slow and rely on the availability of infrastructure and specialist equipment. Rapid diagnostic tests have shown promise under field conditions and further innovations in this area have been proposed. This paper is the protocol for a systematic review focused on identifying current technologies and methods used for cholera diagnosis in stool, and detection in water. We will synthesize and appraise information on product technical specifications, accuracy and design features in order to inform infection prevention and control and innovation development. Embase, MEDLINE, CINAHL, Proquest, IndMed and the WHO and Campbell libraries will be searched. We will include studies reporting on field evaluations, including within-study comparisons against a reference standard, and laboratory evaluations reporting on product validation against field stool or water samples. We will extract data according to protocol and attempt meta-analyses if appropriate given data availability and quality. The systematic review builds on a previous scoping review in this field and expands upon this by synthesising data on both product technical characteristics and design features. The review will be of particular value to stakeholders engaged in diagnostic procurement and manufacturers interested in developing cholera or diarrheal disease diagnostics. PROSPERO CRD42016048428 .

  3. [A novel biologic electricity signal measurement based on neuron chip].

    PubMed

    Lei, Yinsheng; Wang, Mingshi; Sun, Tongjing; Zhu, Qiang; Qin, Ran

    2006-06-01

    Neuron chip is a multiprocessor with three pipeline CPU; its communication protocol and control processor are integrated in effect to carry out the function of communication, control, attemper, I/O, etc. A novel biologic electronic signal measurement network system is composed of intelligent measurement nodes with neuron chip at the core. In this study, the electronic signals such as ECG, EEG, EMG and BOS can be synthetically measured by those intelligent nodes, and some valuable diagnostic messages are found. Wavelet transform is employed in this system to analyze various biologic electronic signals due to its strong time-frequency ability of decomposing signal local character. Better effect is gained. This paper introduces the hardware structure of network and intelligent measurement node, the measurement theory and the signal figure of data acquisition and processing.

  4. [Long-term impact of the diagnostic announcement on the insight of patients suffering from schizophrenic disorders].

    PubMed

    Gastal, D; Januel, D

    2010-06-01

    The importance of insight in patients with schizophrenia is linked to the notion that few subjects are conscious of their pathology and that some treatments fail due to a lack of consciousness of the necessity of medication. Since then, studies have been frequently undertaken into the insight of schizophrenic patients. It is believed that a good degree of insight could influence the quality of acceptance by the patient of the disease. This would facilitate closer medicinal supervision, resulting in fewer relapses and thus a decrease in the number of hospitalizations and subsequent improved quality of life for the patients. In 2002, a protocol of diagnostic announcement was set up for schizophrenic patients in the Ville-Evrard Hospital. Two years later, we observed a high level of compliance in these patients (70 %). The aim of our new study is therefore to assess insight in stabilized schizophrenic patients having benefited from the protocol of diagnostic announcement and to compare their degree of insight with a control population. Two scales of insight were used: the hetero-questionnaire Scale to Assess Unawareness of Mental Disorder (SUMD, Schizophr Bull 17 (1991) 113-32), and the self-questionnaire: Self Appraisal of Ilness Questionnaire (SAIQ, Schizophr Res 45 (2000) 203-11). The clinical symptom of psychosis was assessed by the Positive and Negative Syndrome Scale (PANSS). The Man and Whitney Test was used for the quantitative data and the exact Fisher test for qualitative data. A total of 31 patients were included, 15 in the group having received the diagnostic announcement - population with protocol (P) and 16 in the control group without protocol (SP). The socio-demographic data analysis of the population P (having received the diagnostic announcement) showed a younger population with a shorter evolution of the disease compared to the population "SP". The P group is in demand as regards information on their disorders. In addition, in patients having lived with this disease for many years, these episodes have taken on a taboo status compared to patients in the early stage of the disease. One can consider that the psychiatrists proposed this psycho-informative protocol to younger patients. The results obtained with the SUMD scale were improved in the population "P" as regards development of insight (significantly with the factor 5). Attribution (factor 5) is the factor which the patients had the greatest difficulty estimating. Attribution is the result of external training, rather than awareness which solicits greater introspection. Therefore, psycho-education support played the role of "apprenticeship". Degree of insight was globally of good quality in this questionnaire (compared with the self-questionnaire). Results of the self-questionnaire: SAIQ shows that the degree of insight is quite low in both populations. Few authentic and reflected answers were possible in either of the two groups. However, the presence of a correlation between the overall two scores confirms that we did assess the same phenomenon. The PANSS clinical evaluation shows that the population "P" has symptoms of lesser intensity overall and significantly fewer positive symptoms than the population "SP". The limits of our study are linked to the small number of patients included, despite a homogeneous sample. In conclusion, the protocol of diagnostic announcement and psycho-education have helped stabilize schizophrenic patients in order to improve their insight, without increasing the intensity of this disease in the short- or long-term. Work on insight should allow a new understanding of the patient's relation with the disease along with the medical team and his close relations. Copyright (c) 2009 L'Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.

  5. Measuring multi-configurational character by orbital entanglement

    NASA Astrophysics Data System (ADS)

    Stein, Christopher J.; Reiher, Markus

    2017-09-01

    One of the most critical tasks at the very beginning of a quantum chemical investigation is the choice of either a multi- or single-configurational method. Naturally, many proposals exist to define a suitable diagnostic of the multi-configurational character for various types of wave functions in order to assist this crucial decision. Here, we present a new orbital-entanglement-based multi-configurational diagnostic termed Zs(1). The correspondence of orbital entanglement and static (or non-dynamic) electron correlation permits the definition of such a diagnostic. We chose our diagnostic to meet important requirements such as well-defined limits for pure single-configurational and multi-configurational wave functions. The Zs(1) diagnostic can be evaluated from a partially converged, but qualitatively correct, and therefore inexpensive density matrix renormalisation group wave function as in our recently presented automated active orbital selection protocol. Its robustness and the fact that it can be evaluated at low cost make this diagnostic a practical tool for routine applications.

  6. Electronic patient record and archive of records in Cardio.net system for telecardiology.

    PubMed

    Sierdziński, Janusz; Karpiński, Grzegorz

    2003-01-01

    In modern medicine the well structured patient data set, fast access to it and reporting capability become an important question. With the dynamic development of information technology (IT) such question is solved via building electronic patient record (EPR) archives. We then obtain fast access to patient data, diagnostic and treatment protocols etc. It results in more efficient, better and cheaper treatment. The aim of the work was to design a uniform Electronic Patient Record, implemented in cardio.net system for telecardiology allowing the co-operation among regional hospitals and reference centers. It includes questionnaires for demographic data and questionnaires supporting doctor's work (initial diagnosis, final diagnosis, history and physical, ECG at the discharge, applied treatment, additional tests, drugs, daily and periodical reports). The browser is implemented in EPR archive to facilitate data retrieval. Several tools for creating EPR and EPR archive were used such as: XML, PHP, Java Script and MySQL. The separate question is the security of data on WWW server. The security is ensured via Security Socket Layer (SSL) protocols and other tools. EPR in Cardio.net system is a module enabling the co-work of many physicians and the communication among different medical centers.

  7. Recent advances in tuberculosis diagnostics in resource-limited settings.

    PubMed

    Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi

    2018-04-19

    Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.

  8. Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Y

    2014-03-03

    ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less

  9. Preoperative N Staging of Gastric Cancer by Stomach Protocol Computed Tomography

    PubMed Central

    Kim, Se Hoon; Kim, Jeong Jae; Lee, Jeong Sub; Kim, Seung Hyoung; Kim, Bong Soo; Maeng, Young Hee; Hyun, Chang Lim; Kim, Min Jeong

    2013-01-01

    Purpose Clinical stage of gastric cancer is currently assessed by computed tomography. Accurate clinical staging is important for the tailoring of therapy. This study evaluated the accuracy of clinical N staging using stomach protocol computed tomography. Materials and Methods Between March 2004 and November 2012, 171 patients with gastric cancer underwent preoperative stomach protocol computed tomography (Jeju National University Hospital; Jeju, Korea). Their demographic and clinical characteristics were reviewed retrospectively. Two radiologists evaluated cN staging using axial and coronal computed tomography images, and cN stage was matched with pathologic results. The diagnostic accuracy of stomach protocol computed tomography for clinical N staging and clinical characteristics associated with diagnostic accuracy were evaluated. Results The overall accuracy of stomach protocol computed tomography for cN staging was 63.2%. Computed tomography images of slice thickness 3.0 mm had a sensitivity of 60.0%; a specificity of 89.6%; an accuracy of 78.4%; and a positive predictive value of 78.0% in detecting lymph node metastases. Underestimation of cN stage was associated with larger tumor size (P<0.001), undifferentiated type (P=0.003), diffuse type (P=0.020), more advanced pathologic stage (P<0.001), and larger numbers of harvested and metastatic lymph nodes (P<0.001 each). Tumor differentiation was an independent factor affecting underestimation by computed tomography (P=0.045). Conclusions Computed tomography with a size criterion of 8 mm is highly specific but relatively insensitive in detecting nodal metastases. Physicians should keep in mind that computed tomography may not be an appropriate tool to detect nodal metastases for choosing appropriate treatment. PMID:24156034

  10. Bedside Diagnosis of Dysphagia: A Systematic Review

    PubMed Central

    O’Horo, John C.; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia

    2015-01-01

    Background Dysphagia is associated with aspiration, pneumonia and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. Methods We conducted a comprehensive search of seven databases, including MEDLINE, EMBASE and Scopus, from each database’s earliest inception through June 5th, 2013. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study [VFSS] or flexible endoscopic evaluation of swallowing with sensory testing [FEEST]) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design and prediction of aspiration. Results The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and one description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in post-stroke adults, limiting the generalizability of results. Conclusions No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. PMID:25581840

  11. Diagnostic hearing testing of infants aged 0-36 months in 3 South African provinces - Comparison of audiology records to HPCSA guidelines.

    PubMed

    Moodley, Selvarani; Störbeck, Claudine

    2016-12-01

    Within the Early Hearing Detection and Intervention (EHDI) pathway, which includes the processes of screening, diagnosis and intervention for paediatric hearing loss, paediatric diagnostic audiology involves a battery of specific tests and procedures. International studies have highlighted a golden standard for diagnosis of paediatric hearing loss as based on the Joint Committee of Infant Hearing (2007) diagnostic guidelines, closely resembling the HPCSA diagnostic guidelines. There are limited South African studies on the processes and protocols followed in diagnostic paediatric audiology. This study aims to provide a comparison for how the tests used for diagnosis of paediatric hearing loss in South Africa (within both the public and private healthcare sectors) compare to the HPCSA recommended diagnostic guidelines. A retrospective record review of paediatric clients with hearing loss (recruited through nonprobability convenience sampling) was conducted. This study is part of a longitudinal study of 711 deaf or hard of hearing children referred to the HI HOPES early intervention programme from September 2006 to December 2011. Diagnostic data from audiology reports of 117 children between 0 and 36 months were coded and analysed. Large variation was found in the tests included in the diagnostic audiology reports. For 22 children (19%) a comprehensive test battery was used. Health Professions Council of South Africa (HPCSA) recommended guidelines for diagnostic testing were not followed in any of the records analysed. Components of the HPCSA recommended test battery most frequently omitted was bone conduction testing. For both electrophysiology and behavioural testing, there was limited frequency specificity information. This exclusion of information is evidence of deficiencies in data recording and management, as well as having an effect on accuracy of classification of degree and type of hearing loss. There are gaps in age-appropriate assessment protocols, which will have an effect on accurate differential diagnosis of paediatric hearing loss. Reasons for not including all testing components of the HPCSA recommended guidelines, as well as the possibility of developing guidelines more relevant to a developing world context, should be explored. There might be a need for. The impact of South African specific factors that have an effect on provision of accurate paediatric diagnostic audiology services should be determined. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Cloud-Based CT Dose Monitoring using the DICOM-Structured Report: Fully Automated Analysis in Regard to National Diagnostic Reference Levels.

    PubMed

    Boos, J; Meineke, A; Rubbert, C; Heusch, P; Lanzman, R S; Aissa, J; Antoch, G; Kröpil, P

    2016-03-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDIvol) and dose length product (DLP). Data of 36,523 examinations (131,527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDIvol and DLP were 51.3% and 52.8% of the national DRLs, respectively. CTDIvol and DLP reached 43.8% and 43.1% for abdominal CT (n=10,590), 66.6% and 69.6% for cranial CT (n=16,098) and 37.8% and 44.0% for chest CT (n=10,387) of the compared national DRLs, respectively. Overall, the CTDIvol exceeded national DRLs in 1.9% of the examinations, while the DLP exceeded national DRLs in 2.9% of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50% of the DRLs. The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50% of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments. • The newly developed software based on the DICOM-Structured Report enables large-scale cloud-based CT dose monitoring • The implemented software solution enables automated benchmarking in regard to national DRLs • The local radiation exposure from CT reached approximately 50 % of the national DRLs • The cloud-based approach offers great potential for multi-center dose analysis. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Electron beam diagnostic system using computed tomography and an annular sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elmer, John W.; Teruya, Alan T.

    2015-08-11

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by themore » annular sensor structure.« less

  14. Electron beam diagnostic system using computed tomography and an annular sensor

    DOEpatents

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  15. Very Low Intravenous Contrast Volume Protocol for Computed Tomography Angiography Providing Comprehensive Cardiac and Vascular Assessment Prior to Transcatheter Aortic Valve Replacement in Patients with Chronic Kidney Disease

    PubMed Central

    Pulerwitz, Todd C.; Khalique, Omar K.; Nazif, Tamim N.; Rozenshtein, Anna; Pearson, Gregory D.N.; Hahn, Rebecca T.; Vahl, Torsten P.; Kodali, Susheel K.; George, Isaac; Leon, Martin B.; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J.

    2016-01-01

    Background Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. Methods 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30mL/min) who underwent a novel VLCV protocol (20mL of iohexol at 2.5mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. Results VLCV patients had mean(±SD) age 86±6.5, BMI 23.9±3.4 kg/m2 with 54% men; SCV patients age 83±8.8, BMI 28.7±5.3 kg/m2, 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. Conclusions This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. PMID:27061253

  16. Optic neuritis in paediatric patients: Experience over 27 years and a management protocol.

    PubMed

    Monge Galindo, L; Martínez de Morentín, A L; Pueyo Royo, V; García Iñiguez, J P; Sánchez Marco, S; López-Pisón, J; Peña-Segura, J L

    2018-03-08

    In this article, we present our experience on optic neuritis (ON) and provide a diagnostic/therapeutic protocol, intended to rule out other aetiologies (particularly infection), and a fact sheet for parents. We conducted a descriptive, retrospective study of patients with ON over a 27-year period (1990-2017). A review of the available scientific evidence was performed in order to draft the protocol and fact sheet. Our neuropaediatrics department has assessed 20,744 patients in the last 27 years, of whom 14 were diagnosed with ON: 8 had isolated ON, 1 had multiple sclerosis (MS), 1 had clinically isolated syndrome (CIS), 3 had acute disseminated encephalomyelitis, and 1 had isolated ON and a history of acute disseminated encephalomyelitis one year previously. Patients' age range was 4-13 years; 50% were boys. Eight patients were aged over 10: 7 had isolated ON and 1 had MS. Nine patients had bilateral ON, and 3 had retrobulbar ON. MRI results were normal in 7 patients and showed involvement of the optic nerve only in 2 patients and optic nerve involvement + central nervous system demyelination in 5. Thirteen patients received corticosteroids. One patient had been vaccinated against meningococcus-C the previous month. Progression was favourable, except in the patient with MS. A management protocol and fact sheet are provided. ON usually has a favourable clinical course. In children aged older than 10 years with risk factors for MS or optic neuromyelitis (hyperintensity on brain MRI, oligoclonal bands, anti-NMO antibody positivity, ON recurrence), the initiation of immunomodulatory treatment should be agreed with the neurology department. The protocol is useful for diagnostic decision-making, follow-up, and treatment of this rare disease with potentially major repercussions. The use of protocols and fact sheets is important. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols.

    PubMed

    Amoo-Achampong, Kelms; Nwachukwu, Benedict U; McCormick, Frank

    2016-11-01

    The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder ultrasound examination can be performed within ten minutes. Further, ultrasound provides opportunity to off-set costs through the engagement of revenue generating activity for the orthopedic practice.

  18. System for Configuring Modular Telemetry Transponders

    NASA Technical Reports Server (NTRS)

    Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A system for configuring telemetry transponder cards uses a database of error checking protocol data structures, each containing data to implement at least one CCSDS protocol algorithm. Using a user interface, a user selects at least one telemetry specific error checking protocol from the database. A compiler configures an FPGA with the data from the data structures to implement the error checking protocol.

  19. Patient doses from CT examinations in Turkey.

    PubMed

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.

  20. Comparative muscle study fatigue with sEMG signals during the isotonic and isometric tasks for diagnostics purposes.

    PubMed

    Sarmiento, Jhon F; Benevides, Alessandro B; Moreira, Marcelo H; Elias, Arlindo; Bastos, Teodiano F; Silva, Ian V; Pelegrina, Claudinei C

    2011-01-01

    The study of fatigue is an important tool for diagnostics of disease, sports, ergonomics and robotics areas. This work deals with the analysis of sEMG most important fatigue muscle indicators with use of signal processing in isometric and isotonic tasks with the propose of standardizing fatigue protocol to select the data acquisition and processing with diagnostic proposes. As a result, the slope of the RMS, ARV and MNF indicators were successful to describe the fatigue behavior expected. Whereas that, MDF and AIF indicators failed in the description of fatigue. Similarly, the use of a constant load for sEMG data acquisition was the best strategy in both tasks.

  1. MRI of penile fracture: what should be a tailored protocol in emergency?

    PubMed

    Esposito, Andrea Alessandro; Giannitto, Caterina; Muzzupappa, Claudia; Maccagnoni, Sara; Gadda, Franco; Albo, Giancarlo; Biondetti, Pietro Raimondo

    2016-09-01

    To conduct a review of literature to summarize the existing MRI protocols for penile trauma, suggesting a tailored protocol to reduce costs and time of examination. A systematic search was performed in Medline, Embase, Cochrane Library, and Cinahl databases from 1995 to 2015 to identify studies evaluating penis trauma with MRI examination. Studies were included if there was the description of MRI protocol with at least sequences and orthogonal planes used. We chose a systematic approach for data extraction and descriptive synthesis. 12 articles were included in our study. Among the list of 12 articles: 2 were case reports, 3 were clinical series, and 7 were reviews. Clinical trials were not found. There is no unanimous consensus among the authors. Summarizing the data, the most used protocol is characterized by T2 sequences in three orthogonal planes plus T1 sequences in one plane (either axial or sagittal) without contrast medium injection. There is a lack of a standard protocol. A tailored protocol to answer the diagnostic question, reducing costs and time of examination, is characterized by T2 sequences in three orthogonal planes plus at least a T1 sequence (either axial or sagittal plane).

  2. Molecular property diagnostic suite (MPDS): Development of disease-specific open source web portals for drug discovery.

    PubMed

    Nagamani, S; Gaur, A S; Tanneeru, K; Muneeswaran, G; Madugula, S S; Consortium, Mpds; Druzhilovskiy, D; Poroikov, V V; Sastry, G N

    2017-11-01

    Molecular property diagnostic suite (MPDS) is a Galaxy-based open source drug discovery and development platform. MPDS web portals are designed for several diseases, such as tuberculosis, diabetes mellitus, and other metabolic disorders, specifically aimed to evaluate and estimate the drug-likeness of a given molecule. MPDS consists of three modules, namely data libraries, data processing, and data analysis tools which are configured and interconnected to assist drug discovery for specific diseases. The data library module encompasses vast information on chemical space, wherein the MPDS compound library comprises 110.31 million unique molecules generated from public domain databases. Every molecule is assigned with a unique ID and card, which provides complete information for the molecule. Some of the modules in the MPDS are specific to the diseases, while others are non-specific. Importantly, a suitably altered protocol can be effectively generated for another disease-specific MPDS web portal by modifying some of the modules. Thus, the MPDS suite of web portals shows great promise to emerge as disease-specific portals of great value, integrating chemoinformatics, bioinformatics, molecular modelling, and structure- and analogue-based drug discovery approaches.

  3. Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjarnason, Thorarin

    Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used inmore » this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.« less

  4. Evaluation of Efficacy of Bone Scan With SPECT/CT in the Management of Low Back Pain: A Study Supported by Differential Diagnostic Local Anesthetic Blocks.

    PubMed

    Jain, Anuj; Jain, Suruchi; Agarwal, Anil; Gambhir, Sanjay; Shamshery, Chetna; Agarwal, Amita

    2015-12-01

    Conventional radiologic modalities provide details only about the anatomic aspect of the various structures of the spine. Frequently the structures that show abnormal morphology may not be the cause of low back pain (LBP). Functional imaging in the form of bone scan along with single photon emission computerized tomography (SPECT/CT) may be helpful in identifying structures causing pain, whether morphologically normal or not. The objective of this study is to evaluate the role of bone scan with SPECT/CT in management of patients with LBP. This is randomized double-blinded controlled study performed on 80 patients with LBP aged 20 to 80 years, ASA physical status I to III. Patients were randomized into bone scan and control groups consisting of 40 patients each. On the basis of the clinical features and radiologic findings a clinical diagnosis was made. After making a clinical diagnosis, the patients in bone scan group were subjected to bone scan with SPECT/CT. On the basis of the finding of the bone scan and SPECT/CT, a new working diagnosis was made and intervention was performed according to the new working diagnosis. Diagnostic blocks in the control group were given based on clinical diagnosis. Controlled comparative diagnostic blocks were performed with local anesthetic. The pain score just after the diagnostic block and at the time of discharge (approximately 4 h later) was recorded; the pain relief was recorded in percentage. In both the groups, sacroilitis was the most common diagnosis followed by facet joint arthropathy. The number of patients obtaining pain relief of >50% was significantly higher in the bone scan-positive group as compared with the control group. Three new clinical conditions were identified in the bone scan group. These conditions were multiple myeloma, avascular necrosis of the femoral head, and ankylosing spondylitis. Bone scan with SPECT/CT was found to complement the clinical workup of patients with LBP. Inclusion of bone scan with SPECT/CT in LBP management protocol can help in making a correct diagnosis. At times it might bring out some new information that may be vital for further management of the patients with LBP.

  5. Diagnostic Sampling to Reveal Hidden Lead and Copper Health Risks

    EPA Science Inventory

    Lead, copper and other metallic contamination sources in premise drinking water plumbing systems, are unevenly distributed and are usually hidden from thought, view, or both. Many sampling protocols exist, each with some set of implicit assumptions governing its applicability to...

  6. SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, L; Khan, M; Alapati, K

    2015-06-15

    Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with threemore » protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy.« less

  7. Dose reduction in whole-body computed tomography of multiple injuries (DoReMI): protocol for a prospective cohort study

    PubMed Central

    2014-01-01

    Background Single-pass, contrast-enhanced whole body multidetector computed tomography (MDCT) emerged as the diagnostic standard for evaluating patients with major trauma. Modern iterative image algorithms showed high image quality at a much lower radiation dose in the non-trauma setting. This study aims at investigating whether the radiation dose can safely be reduced in trauma patients without compromising the diagnostic accuracy and image quality. Methods/Design Prospective observational study with two consecutive cohorts of patients. Setting: A high-volume, academic, supra-regional trauma centre in Germany. Study population: Consecutive male and female patients who 1. had been exposed to a high-velocity trauma mechanism, 2. present with clinical evidence or high suspicion of multiple trauma (predicted Injury Severity Score [ISS] ≥16) and 3. are scheduled for primary MDCT based on the decision of the trauma leader on call. Imaging protocols: In a before/after design, a consecutive series of 500 patients will undergo single-pass, whole-body 128-row multi-detector computed tomography (MDCT) with a standard, as low as possible radiation dose. This will be followed by a consecutive series of 500 patients undergoing an approved ultra-low dose MDCT protocol using an image processing algorithm. Data: Routine administrative data and electronic patient records, as well as digital images stored in a picture archiving and communications system will serve as the primary data source. The protocol was approved by the institutional review board. Main outcomes: (1) incidence of delayed diagnoses, (2) diagnostic accuracy, as correlated to the reference standard of a synopsis of all subsequent clinical, imaging, surgical and autopsy findings, (3) patients’ safety, (4) radiation exposure (e.g. effective dose), (5) subjective image quality (assessed independently radiologists and trauma surgeons on a 100-mm visual analogue scale), (6) objective image quality (e.g., contrast-to-noise ratio). Analysis: Multivariate regression will be employed to adjust and correct the findings for time and cohort effects. An exploratory interim analysis halfway after introduction of low-dose MDCT will be conducted to assess whether this protocol is clearly inferior or superior to the current standard. Discussion Although non-experimental, this study will generate first large-scale data on the utility of imaging-enhancing algorithms in whole-body MDCT for major blunt trauma. Trial registration Current Controlled Trials ISRCTN74557102. PMID:24589310

  8. Role of Investigating Thrombophilic Disorders in Young Stroke

    PubMed Central

    Ng, Kay W. P.; Loh, Pei K.; Sharma, Vijay K.

    2011-01-01

    Our knowledge about various inherited and acquired causes of thrombophilic disorders has increased significantly during the past decade. Technology for various diagnostic tests for these rare disorders has matched the rapid advances in our understanding about the thrombophilic disorders. Inherited thrombophilic disorders predispose young patients for various venous or arterial thrombotic and thromboembolic episodes. Our understanding has also improved about various gene-gene and gene-environment interactions and their impact on the resultant heterogenous clinical manifestations. We describe various thrombophilic disorders, their diagnostic tests, pathogenic potential in isolation or with other concurrent inherited/acquired defects and possible therapeutic and prophylactic strategies. Better understanding, optimal diagnostic and screening protocols are expected to improve the diagnostic yield and help to reduce morbidity, disability, and mortality in relatively younger patients harbouring these inherited and acquired thrombophilic disorders. PMID:21331344

  9. The IHS diagnostic X-ray equipment radiation protection program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knapp, A.; Byrns, G.; Suleiman, O.

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using themore » National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload.« less

  10. Telehematology: a pilot experience of cytological diagnosis of acute myeloid leukemia via the Internet. A GOELAMS study.

    PubMed

    Leymarie, Vincent; Flandrin, Georges; Noguera, Maria Elena; Leymarie, Florence; Lioure, Bruno; Daliphard, Sylvie

    2006-09-01

    Although modern communication technology is well developed, telehematology does not readily lend itself to practical laboratory use. Multicenter therapeutic protocols may offer preferential opportunities. The cytologists of the AML-2001 protocol established an innovative organization to demonstrate the reliability of the diagnostic assessment of acute myeloid leukemia through a rapid and decentralized exchange of information via the internet and to define the conditions optimizing expert diagnosis. Telediagnosis appears to be a powerful tool for cytological review and other issues.

  11. Geographic variation in lumbar diskectomy: a protocol for evaluation.

    PubMed

    Barron, M; Kazandjian, V A

    1992-03-01

    In 1989 the Maryland Hospital Association (MHA) began developing a protocol related to lumbar diskectomy, a procedure with widely reported geographic variation in its use. The MHA's Laminectomy Advisory Committee drafted three criteria for performance of lumbar diskectomy and also developed a data-collection instrument with which the eight hospitals participating in a pilot study could abstract the necessary data from medical records. Both individual hospital and aggregate results showed wide variation in compliance with the criteria. These findings suggest research and development activities such as refinement of the data-collection instrument, use of the protocol for bench-marking, further investigation of clinical and other determinants of rate variation, and study of the effect of new diagnostic technology on utilization rates for this procedure.

  12. Need low-cost networking? Consider DeviceNet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moss, W.H.

    1996-11-01

    The drive to reduce production costs and optimize system performance in manufacturing facilities causes many end users to invest in network solutions. Because of distinct differences between the way tasks are performed and the way data are handled for various applications, it is clear than more than one network will be needed in most facilities. What is not clear is which network is most appropriate for a given application. The information layer is the link between automation and information environments via management information systems (MISs) and manufacturing execution systems (MESs) and manufacturing execution systems (MESs). Here the market has chosenmore » a de facto standard in Ethernet, primarily transmission control protocol/internet protocol (TCP/IP) and secondarily manufacturing messaging system (MMS). There is no single standard at the device layer. However, the DeviceNet communication standard has made strides to reach this goal. This protocol eliminates expensive hardwiring and provides improved communication between devices and important device-level diagnostics not easily accessible or available through hardwired I/O interfaces. DeviceNet is a low-cost communications link connecting industrial devices to a network. Many original equipment manufacturers and end users have chosen the DeviceNet platform for several reasons, but most frequently because of four key features: interchangeability; low cost; advanced diagnostics; insert devices under power.« less

  13. Validation of a new radiographic protocol for Asian elephant feet and description of their radiographic anatomy.

    PubMed

    Mumby, C; Bouts, T; Sambrook, L; Danika, S; Rees, E; Parry, A; Rendle, M; Masters, N; Weller, R

    2013-10-05

    Foot problems are extremely common in elephants and radiography is the only imaging method available but the radiographic anatomy has not been described in detail. The aims of this study were to develop a radiographic protocol for elephant feet using digital radiography, and to describe the normal radiographic anatomy of the Asian elephant front and hind foot. A total of fifteen cadaver foot specimens from captive Asian elephants were radiographed using a range of projections and exposures to determine the best radiographic technique. This was subsequently tested in live elephants in a free-contact setting. The normal radiographic anatomy of the Asian elephant front and hind foot was described with the use of three-dimensional models based on CT reconstructions. The projection angles that were found to be most useful were 65-70° for the front limb and 55-60° in the hind limb. The beam was centred 10-15 cm proximal to the cuticle in the front and 10-15 cm dorsal to the plantar edge of the sole in the hind foot depending on the size of the foot. The protocol developed can be used for larger-scale diagnostic investigations of captive elephant foot disorders, while the normal radiographic anatomy described can improve the diagnostic reliability of elephant feet radiography.

  14. The expanding cognitive-behavioural therapy treatment umbrella for the anxiety disorders: disorder-specific and transdiagnostic approaches.

    PubMed

    Rector, Neil A; Man, Vincent; Lerman, Bethany

    2014-06-01

    Cognitive-behavioural therapy (CBT) is an empirically supported treatment for anxiety disorders. CBT treatments are based on disorder-specific protocols that have been developed to target individual anxiety disorders, despite that anxiety disorders frequently co-occur and are comorbid with depression. Given the high rates of diagnostic comorbidity, substantial overlap in dimensional symptom ratings, and extensive evidence that the mood and anxiety disorders share a common set of psychological and biological vulnerabilities, transdiagnostic CBT protocols have recently been developed to treat the commonalities among the mood and anxiety disorders. We conducted a selective review of empirical developments in the transdiagnostic CBT treatment of anxiety and depression (2008-2013). Preliminary evidence suggests that theoretically based transdiagnostic CBT approaches lead to large treatment effects on the primary anxiety disorder, considerable reduction of diagnostic comorbidity, and some preliminary effects regarding the impact on the putative, shared psychological mechanisms. However, the empirical literature remains tentative owing to relatively small samples, limited direct comparisons with disorder-specific CBT protocols, and the relative absence of the study of disorder-specific compared with shared mechanisms of action in treatment. We conclude with a treatment conceptualization of the new transdiagnostic interventions as complementary, rather than contradictory, to disorder-specific CBT.

  15. Acute acquired toxoplasmosis: clinical-laboratorial aspects and ophthalmologic evaluation in a cohort of immunocompetent patients.

    PubMed

    Neves, E S; Bicudo, L N; Curi, A L; Carregal, E; Bueno, W F; Ferreira, R G; Amendoeira, M R; Benchimol, E; Fernandes, O

    2009-03-01

    Most cases of acute acquired toxoplasmosis (AAT) are oligosymptomatic and self-limited. Therefore, these infections rarely indicate treatment. Prospective studies of AAT patients are rare in the medical literature. The frequency of systemic manifestations has not been sufficiently studied. In order to search for risks factors for systemic and ocular involvement, 37 patients were submitted to a diagnostic investigative protocol. The most frequent findings were lymph node enlargement (94.6%), asthenia (86.5%), headache (70.3%), fever (67.6%) and weight loss (62.2%). Hepatomegaly and/or splenomegaly were present in 21.6% of cases (8/37). Liver transaminases were elevated in 11 patients (29.7%) and lactic dehydrogenase in 17 patients (45.9%). Anaemia was found in four patients (10.8%), leucopoenia in six patients (16.2%), lymphocytosis in 14 patients (37.8%) and thrombocytopenia in one patient (2.7%). Fundoscopic examination revealed retinochoroiditis in four patients (10.8%). No statistical association was found between any one morbidity and retinochoroiditis. Nevertheless, a significant association was found between the presence of more than eight morbidity features at evaluation and long-lasting disease. An ideal diagnostic protocol for AAT would include evidence of systemic involvement. Such a protocol could be used when planning treatment.

  16. A Streamlined Protocol for Molecular Testing of the DMD Gene within a Diagnostic Laboratory: A Combination of Array Comparative Genomic Hybridization and Bidirectional Sequence Analysis

    PubMed Central

    Marquis-Nicholson, Renate; Lai, Daniel; Love, Jennifer M.; Love, Donald R.

    2013-01-01

    Purpose. The aim of this study was to develop a streamlined mutation screening protocol for the DMD gene in order to confirm a clinical diagnosis of Duchenne or Becker muscular dystrophy in affected males and to clarify the carrier status of female family members. Methods. Sequence analysis and array comparative genomic hybridization (aCGH) were used to identify mutations in the dystrophin DMD gene. We analysed genomic DNA from six individuals with a range of previously characterised mutations and from eight individuals who had not previously undergone any form of molecular analysis. Results. We successfully identified the known mutations in all six patients. A molecular diagnosis was also made in three of the four patients with a clinical diagnosis who had not undergone prior genetic screening, and testing for familial mutations was successfully completed for the remaining four patients. Conclusion. The mutation screening protocol described here meets best practice guidelines for molecular testing of the DMD gene in a diagnostic laboratory. The aCGH method is a superior alternative to more conventional assays such as multiplex ligation-dependent probe amplification (MLPA). The combination of aCGH and sequence analysis will detect mutations in 98% of patients with the Duchenne or Becker muscular dystrophy. PMID:23476807

  17. Optimization of the protocols for the use of contrast agents in PET/CT studies.

    PubMed

    Pelegrí Martínez, L; Kohan, A A; Vercher Conejero, J L

    The introduction of PET/CT scanners in clinical practice in 1998 has improved care for oncologic patients throughout the clinical pathway, from the initial diagnosis of disease through the evaluation of the response to treatment to screening for possible recurrence. The CT component of a PET/CT study is used to correct the attenuation of PET studies; CT also provides anatomic information about the distribution of the radiotracer. CT is especially useful in situations where PET alone can lead to false positives and false negatives, and CT thereby improves the diagnostic performance of PET. The use of intravenous or oral contrast agents and optimal CT protocols have improved the detection and characterization of lesions. However, there are circumstances in which the systematic use of contrast agents is not justified. The standard acquisition in PET/CT scanners is the whole body protocol, but this can lead to artifacts due to the position of patients and respiratory movements between the CT and PET acquisitions. This article discusses these aspects from a constructive perspective with the aim of maximizing the diagnostic potential of PET/CT and providing better care for patients. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.

    2010-04-15

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less

  19. Diagnostic imaging modalities in head and neck disease.

    PubMed

    Dammann, Florian; Bootz, Friedrich; Cohnen, Mathias; Hassfeld, Stefan; Tatagiba, Marcos; Kösling, Sabrina

    2014-06-09

    Because of the complex anatomy of the head and neck region, conventional projection radiography alone is unreliable and carries a high risk of misdiagnosis. The poor risk-benefit ratio of conventional radiography has led to their replacement by tomographic imaging for nearly all studies in this region. This review is based on pertinent articles retrieved by a selective search in the PubMed database (January 1980 to May 2013) as well as on the relevant guidelines from Germany and abroad. The indication for diagnostic imaging in the anatomically complex head and neck region should be established for a specific type of imaging study on the basis of a thorough clinical examination. Conventional films, though easy to obtain, often cannot answer the diagnostic question and may yield confusing information leading to misdiagnosis. Computed tomography (CT) has the best risk-benefit profile and a high diagnostic value, but low-dose protocols have not yet been put into use in all centers. Magnetic resonance imaging (MRI) is best for bone and soft-tissue diagnosis, but consumes more resources. Digital volume tomography (DVT) is another type of three-dimensional, sectional imaging with high local resolution; the associated radiation exposure and image quality are generally both low, but may vary depending on the apparatus used. DVT cannot be used to evaluate the soft tissues. Ultrasonography can be used to evaluate superficial structures in the head and neck region; nuclear imaging can be used to evaluate thyroid disease and cancer. Inflammatory, traumatic, and neoplastic diseases of the head and neck are best evaluated with cross-sectional imaging (CT, MRI) in accordance with current guidelines. Conventional x-rays should, in general, only be used for dental evaluation, with rare exceptions.

  20. Bench-Top Fabrication of an All-PDMS Microfluidic Electrochemical Cell Sensor Integrating Micro/Nanostructured Electrodes.

    PubMed

    Saem, Sokunthearath; Zhu, Yujie; Luu, Helen; Moran-Mirabal, Jose

    2017-03-31

    In recent years, efforts in the development of lab-on-a-chip (LoC) devices for point-of-care (PoC) applications have increased to bring affordable, portable, and sensitive diagnostics to the patients' bedside. To reach this goal, research has shifted from using traditional microfabrication methods to more versatile, rapid, and low-cost options. This work focuses on the benchtop fabrication of a highly sensitive, fully transparent, and flexible poly (dimethylsiloxane) (PDMS) microfluidic (μF) electrochemical cell sensor. The μF device encapsulates 3D structured gold and platinum electrodes, fabricated using a shape-memory polymer shrinking method, which are used to set up an on-chip electrochemical cell. The PDMS to PDMS-structured electrode bonding protocol to fabricate the μF chip was optimized and found to have sufficient bond strength to withstand up to 100 mL/min flow rates. The sensing capabilities of the on-chip electrochemical cell were demonstrated by using cyclic voltammetry to monitor the adhesion of murine 3T3 fibroblasts in the presence of a redox reporter. The charge transfer across the working electrode was reduced upon cell adhesion, which was used as the detection mechanism, and allowed the detection of as few as 24 cells. The effective utilization of simple and low cost bench-top fabrication methods could accelerate the prototyping and development of LoC technologies and bring PoC diagnostics and personalized medicine to the patients' bedside.

  1. Bench-Top Fabrication of an All-PDMS Microfluidic Electrochemical Cell Sensor Integrating Micro/Nanostructured Electrodes

    PubMed Central

    Saem, Sokunthearath; Zhu, Yujie; Luu, Helen; Moran-Mirabal, Jose

    2017-01-01

    In recent years, efforts in the development of lab-on-a-chip (LoC) devices for point-of-care (PoC) applications have increased to bring affordable, portable, and sensitive diagnostics to the patients’ bedside. To reach this goal, research has shifted from using traditional microfabrication methods to more versatile, rapid, and low-cost options. This work focuses on the benchtop fabrication of a highly sensitive, fully transparent, and flexible poly (dimethylsiloxane) (PDMS) microfluidic (μF) electrochemical cell sensor. The μF device encapsulates 3D structured gold and platinum electrodes, fabricated using a shape-memory polymer shrinking method, which are used to set up an on-chip electrochemical cell. The PDMS to PDMS-structured electrode bonding protocol to fabricate the μF chip was optimized and found to have sufficient bond strength to withstand up to 100 mL/min flow rates. The sensing capabilities of the on-chip electrochemical cell were demonstrated by using cyclic voltammetry to monitor the adhesion of murine 3T3 fibroblasts in the presence of a redox reporter. The charge transfer across the working electrode was reduced upon cell adhesion, which was used as the detection mechanism, and allowed the detection of as few as 24 cells. The effective utilization of simple and low cost bench-top fabrication methods could accelerate the prototyping and development of LoC technologies and bring PoC diagnostics and personalized medicine to the patients’ bedside. PMID:28362329

  2. On-chip purification and detection of hepatitis C virus RNA from human plasma.

    PubMed

    Vaghi, V; Potrich, C; Pasquardini, L; Lunelli, L; Vanzetti, L; Ebranati, E; Lai, A; Zehender, G; Mombello, D; Cocuzza, M; Pirri, C F; Pederzolli, C

    2016-01-01

    Hepatitis C virus (HCV) is one of the main causes of chronic liver disease worldwide. The diagnosis and monitoring of HCV infection is a crucial need in the clinical management. The conventional diagnostic technologies are challenged when trying to address molecular diagnostics, especially because they require a complex and time-consuming sample preparation phase. Here, a new concept based on surface functionalization was applied to viral RNA purification: first of all polydimethylsiloxane (PDMS) flat surfaces were modified to hold RNA adsorption. After a careful chemical and morphological analysis of the modified surfaces, the functionalization protocols giving the best RNA adsorbing surfaces were applied to PDMS microdevices. The functionalized microdevices were then used for RNA purification from HCV infected human plasma samples. RNA purification and RT were successfully performed in the same microdevice chamber, saving time of analysis, reagents, and labor. The PCR protocol for HCV cDNA amplification was also implemented in the microdevice, demonstrating that the entire process of HCV analysis, from plasma to molecular readout, could be performed on-chip. Not only HCV but also other microdevice-based viral RNA detection could therefore result in a successful Point-of-Care (POC) diagnostics for resource-limited settings. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Ultrasound elastography in diagnosis and follow-up for patients with chronic recurrent parotitis.

    PubMed

    Zengel, Pamela; Reichel, Christoph Andreas; Vincek, Teresa; Clevert, Dirk André

    2017-01-01

    Chronic recurrent parotitis (CRP) is a non-obstructive disease with episodes characterized by painful swelling of the parotid gland. It presents in both a juvenile and an adult form, with no clear information on its actual origin. Diagnosis is based on patient medical history and ultrasound examination but is frequently not correctly identified. Acoustic Radiation Force Impulse Imaging (ARFI) is a novel ultrasound elastography technology that has recently been implemented in the diagnostic work-up of patients with malignancies. This study aimed to answer whether ARFI can reasonably be employed in the initial examination and follow-up during therapy in patients with CRP. Mechanical tissue properties of the salivary glands were analyzed by ARFI in 37 parotid glands of patients with CRP. Having integrated ARFI into our diagnostic protocol for CRP, affected parotid glands were found to exhibit lower tissue elasticity compared to both healthy contralateral glands in the same individuals as well as those of healthy individuals. Most importantly, this method enabled us to quantitatively assess the patient benefit of therapy regarding the recovery of the glands' diseased parenchyma. ARFI provides a quick, easy, and reliable diagnostic tool for the assessment of disease severity and progression in patients with CRP that can be seamlessly implemented into preexisting ultrasound protocols.

  4. Video Diagnostic for W7-X Stellarator

    NASA Astrophysics Data System (ADS)

    Sárközi, J.; Grosser, K.; Kocsis, G.; König, R.; Neuner, U.; Molnár, Á.; Petravich, G.; Por, G.; Porempovics, G.; Récsei, S.; Szabó, V.; Szappanos, A.; Zoletnik, S.

    2008-03-01

    The video diagnostics for W7-X—which is under development—is devoted to observe plasma and frrst wall elements during operation, to warn in case of hot spots and dangerous heat load and to give information about the plasma size, position, edge structure, the geometry and location of magnetic islands and distribution of impurities. The video diagnostics will be mounted on the tangential AEQ-ports of the torus that are not straight and have about 2m length and a typical diameter of 0.1m which makes its realization more difficult. The geometry of the 10 tangential views of the AEQ-ports allows giving an almost complete overview of the vessel interior making this diagnostic indispensable for the machine operation. Different concepts of the diagnostics were investigated and finally the following design was selected. As a large heat load is expected on the optical window located at the plasma-facing end of the AEQ-port, the port window is protected by a cooled pinhole. An uncooled shutter located behind the pinhole can be closed to prevent window contamination during vessel conditioning discharges (glow discharge cleaning) and from inter-pulse deposition of soft a-C:H layers. The imaging optics and the detection sensor are located behind the port window in the port tube, which will be under atmospheric pressure. To detect the visible radiation distribution a new camera system called Event Detection Intelligent Camera (EDICAM) is under development. The system is divided into three major separated components. The Sensor Module contains only the selected CMOS sensor, the analog digital converters and the minimal electronics necessary for the communication with the subsequent camera system module called Image Processing and Control Unit (IPCU). Its simple structure makes the Sensor Module suitable to operate despite being exposed to ionizing (neutron, γ-) radiation. The IPCU, which can be located far from the Sensor Module and therefore far from the plasma, is designed to perform real time evaluation of the images detecting predefined events, managing the sensor read-out and the input triggers and producing the output triggers generated by the detected events. The IPCU can also be used to reduce the amount of the stored data. A Standard 10 Gigabit Ethernet fiber optics connection connects the IPCU module to the PC with GigEVision communication protocol.

  5. Diagnosis of Alzheimer’s disease in Brazil: Supplementary exams

    PubMed Central

    Caramelli, Paulo; Teixeira, Antonio Lúcio; Buchpiguel, Carlos Alberto; Lee, Hae Won; Livramento, José Antônio; Fernandez, Liana Lisboa; Anghinah, Renato

    2011-01-01

    This article presents a review of the recommendations on supplementary exams employed for the clinical diagnosis of Alzheimer’s disease (AD) in Brazil published in 2005. A systematic assessment of the consensus reached in other countries, and of articles on AD diagnosis in Brazil available on the PUBMED and LILACS medical databases, was carried out. Recommended laboratory exams included complete blood count, serum creatinine, thyroid stimulating hormone (TSH), albumin, hepatic enzymes, Vitamin B12, folic acid, calcium, serological reactions for syphilis and serology for HIV in patients aged younger than 60 years with atypical clinical signs or suggestive symptoms. Structural neuroimaging, computed tomography or – preferably – magnetic resonance exams, are indicated for diagnostic investigation of dementia syndrome to rule out secondary etiologies. Functional neuroimaging exams (SPECT and PET), when available, increase diagnostic reliability and assist in the differential diagnosis of other types of dementia. The cerebrospinal fluid exam is indicated in cases of pre-senile onset dementia with atypical clinical presentation or course, for communicant hydrocephaly, and suspected inflammatory, infectious or prion disease of the central nervous system. Routine electroencephalograms aid the differential diagnosis of dementia syndrome with other conditions which impair cognitive functioning. Genotyping of apolipoprotein E or other susceptibility polymorphisms is not recommended for diagnostic purposes or for assessing the risk of developing the disease. Biomarkers related to the molecular alterations in AD are largely limited to use exclusively in research protocols, but when available can contribute to improving the accuracy of diagnosis of the disease. PMID:29213741

  6. Microfluidic differential immunocapture biochip for specific leukocyte counting

    PubMed Central

    Hassan, Umer; Watkins, Nicholas N; Reddy, Bobby; Damhorst, Gregory; Bashir, Rashid

    2016-01-01

    Enumerating specific cell types from whole blood can be very useful for research and diagnostic purposes—e.g., for counting of cD4 and cD8 t cells in HIV/aIDs diagnostics. We have developed a biosensor based on a differential immunocapture technology to enumerate specific cells in 30 min using 10 µl of blood. this paper provides a comprehensive stepwise protocol to replicate our biosensor for cD4 and cD8 cell counts. the biochip can also be adapted to enumerate other specific cell types such as somatic cells or cells from tissue or liquid biopsies. capture of other specific cells requires immobilization of their corresponding antibodies within the capture chamber. therefore, this protocol is useful for research into areas surrounding immunocapture-based biosensor development. the biosensor production requires 24 h, a one-time cell capture optimization takes 6–9 h, and the final cell counting experiment in a laboratory environment requires 30 min to complete. PMID:26963632

  7. PSMA Theranostics: Current Status and Future Directions

    PubMed Central

    Afshar-Oromieh, Ali; Jadvar, Hossein; Ahmadzadehfar, Hojjat

    2018-01-01

    Prostate-specific membrane antigen (PSMA) is a promising target for imaging diagnostics and targeted radionuclide therapy (theranostics) of prostate cancer and its metastases. There is increasing evidence of encouraging response rates and a low toxicity profile of radioligand therapy (RLT) of metastatic castration-resistant prostate cancer using 177Lu-labeled PSMA ligands. In this article, we review the current status of diagnostics and therapy using radiolabeled PSMA ligands. We also suggest protocols for patient selection criteria and conduct of PSMA-based RLT. Challenges and opportunities of PSMA theranostics are discussed. PMID:29873291

  8. Electro-mechanical probe positioning system for large volume plasma device

    NASA Astrophysics Data System (ADS)

    Sanyasi, A. K.; Sugandhi, R.; Srivastava, P. K.; Srivastav, Prabhakar; Awasthi, L. M.

    2018-05-01

    An automated electro-mechanical system for the positioning of plasma diagnostics has been designed and implemented in a Large Volume Plasma Device (LVPD). The system consists of 12 electro-mechanical assemblies, which are orchestrated using the Modbus communication protocol on 4-wire RS485 communications to meet the experimental requirements. Each assembly has a lead screw-based mechanical structure, Wilson feed-through-based vacuum interface, bipolar stepper motor, micro-controller-based stepper drive, and optical encoder for online positioning correction of probes. The novelty of the system lies in the orchestration of multiple drives on a single interface, fabrication and installation of the system for a large experimental device like the LVPD, in-house developed software, and adopted architectural practices. The paper discusses the design, description of hardware and software interfaces, and performance results in LVPD.

  9. Mixed Methods Survey of Zoonotic Disease Awareness and Practice among Animal and Human Healthcare Providers in Moshi, Tanzania

    PubMed Central

    Zhang, Helen L.; Mnzava, Kunda W.; Mitchell, Sarah T.; Melubo, Matayo L.; Kibona, Tito J.; Cleaveland, Sarah; Kazwala, Rudovick R.; Crump, John A.; Sharp, Joanne P.; Halliday, Jo E. B.

    2016-01-01

    Background Zoonoses are common causes of human and livestock illness in Tanzania. Previous studies have shown that brucellosis, leptospirosis, and Q fever account for a large proportion of human febrile illness in northern Tanzania, yet they are infrequently diagnosed. We conducted this study to assess awareness and knowledge regarding selected zoonoses among healthcare providers in Moshi, Tanzania; to determine what diagnostic and treatment protocols are utilized; and obtain insights into contextual factors contributing to the apparent under-diagnosis of zoonoses. Methodology/Results We conducted a questionnaire about zoonoses knowledge, case reporting, and testing with 52 human health practitioners and 10 livestock health providers. Immediately following questionnaire administration, we conducted semi-structured interviews with 60 of these respondents, using the findings of a previous fever etiology study to prompt conversation. Sixty respondents (97%) had heard of brucellosis, 26 (42%) leptospirosis, and 20 (32%) Q fever. Animal sector respondents reported seeing cases of animal brucellosis (4), rabies (4), and anthrax (3) in the previous 12 months. Human sector respondents reported cases of human brucellosis (15, 29%), rabies (9, 18%) and anthrax (6, 12%). None reported leptospirosis or Q fever cases. Nineteen respondents were aware of a local diagnostic test for human brucellosis. Reports of tests for human leptospirosis or Q fever, or for any of the study pathogens in animals, were rare. Many respondents expressed awareness of malaria over-diagnosis and zoonoses under-diagnosis, and many identified low knowledge and testing capacity as reasons for zoonoses under-diagnosis. Conclusions This study revealed differences in knowledge of different zoonoses and low case report frequencies of brucellosis, leptospirosis, and Q fever. There was a lack of known diagnostic services for leptospirosis and Q fever. These findings emphasize a need for improved diagnostic capacity alongside healthcare provider education and improved clinical guidelines for syndrome-based disease management to provoke diagnostic consideration of locally relevant zoonoses in the absence of laboratory confirmation. PMID:26943334

  10. Study protocol of the internet user Cohort for Unbiased Recognition of gaming disorder in Early adolescence (iCURE), Korea, 2015–2019

    PubMed Central

    Jeong, Hyunsuk; Jo, Sun-Jin; Lee, Seung-Yup; Kim, Eunjin; Son, Hye Jung; Han, Hyun-ho; Lee, Hae Kook; Kweon, Yong-Sil; Bhang, Soo-young; Choi, Jung-Seok; Kim, Bung-Nyun; Gentile, Douglas A; Potenza, Marc N

    2017-01-01

    Introduction In 2013, the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) proposed nine internet gaming disorder (IGD) diagnostic criteria as a condition warranting further empirical and clinical research. The aim of this study is to clarify the natural and clinical courses of IGD proposed DSM-5 in adolescents and to evaluate its risk and protective factors. Methods and analysis The Internet user Cohort for Unbiased Recognition of gaming disorder in Early Adolescence (iCURE) study is an ongoing multidisciplinary, prospective, longitudinal cohort study conducted in 21 schools in Korea. Participant recruitment commenced in March 2015 with the goal of registering 3000 adolescents. The baseline assessment included surveys on emotional, social and environmental characteristics. A parent or guardian completed questionnaires and a structured psychiatric comorbidity diagnostic interview regarding their children. Adolescents with the Internet Game Use-Elicited Symptom Screen total scores of 6 or higher were asked to participate in the clinical diagnostic interview. Two subcohorts of adolescents were constructed: a representative subcohort and a clinical evaluation subcohort. The representative subcohort comprises a randomly selected 10% of the iCURE to investigate the clinical course of IGD based on clinical diagnosis and to estimate the false negative rate. The clinical evaluation subcohort comprised participants meeting three or more of the nine IGD criteria, determined by clinical diagnostic interview, to show the clinical course of IGD. Follow-up data will be collected annually for the 3 years following the baseline assessments. The primary endpoint is 2-year incidence, remission and recurrence rates of IGD. Cross-sectional and longitudinal associations between exposures and outcomes as well as mediation factors will be evaluated. Ethics and dissemination This study is approved by the Institutional Review Board of the Catholic University of Korea. Results will be published in peer-reviewed journals. Trial registration number ClinicalTrials.gov (identifier: NCT02415322). PMID:28982839

  11. An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.

    PubMed

    Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa

    2016-04-01

    To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS(®) assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1%) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.

    PubMed

    Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa

    2016-11-01

    To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS ® assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1 %) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. An optimized 13C-urea breath test for the diagnosis of H pylori infection

    PubMed Central

    Campuzano-Maya, Germán

    2007-01-01

    AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy. METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol. RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively. CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost. PMID:17907288

  14. Lessons Learned From The Investigational Device Exemption (IDE) Review of Children's Oncology Group Trial AAML1031

    PubMed Central

    Meshinchi, Soheil; Hunger, Stephen P.; Aplenc, Richard; Adamson, Peter C.; Jessup, J. Milburn

    2012-01-01

    The FDA is now exerting its regulatory authority over molecular diagnostics and their assays used for medical-decision making in clinical trials by performing pre-Investigational Device Exemption (IDE) reviews in all phases of clinical trials. This review assesses the analytical performance of the assay for the diagnostic and considers how that performance affects the diagnostic and the patient and their risks and benefits from treatment. This manuscript reviews the process of the first review that was performed on a new Children's Oncology Group (COG) Phase III trial in Acute Myelogenous Leukemia. The lessons learned and recommendations for how to prepare for and incorporate this new level of regulatory review into the protocol development process are presented. PMID:22422407

  15. Biogeochemical Protocols and Diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    NASA Technical Reports Server (NTRS)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; hide

    2017-01-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF [subscript] 6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.

  16. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    NASA Astrophysics Data System (ADS)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; Griffies, Stephen M.; John, Jasmin G.; Joos, Fortunat; Levin, Ingeborg; Lindsay, Keith; Matear, Richard J.; McKinley, Galen A.; Mouchet, Anne; Oschlies, Andreas; Romanou, Anastasia; Schlitzer, Reiner; Tagliabue, Alessandro; Tanhua, Toste; Yool, Andrew

    2017-06-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are founded on those from previous phases of the Ocean Carbon-Cycle Model Intercomparison Project. They have been merged and updated to reflect improvements concerning gas exchange, carbonate chemistry, and new data for initial conditions and atmospheric gas histories. Code is provided to facilitate their implementation.

  17. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... a cell panel intended for identification of unexpected antibodies. The sample shall be packaged as... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  18. What Do Lead and Copper Sampling Protocols Mean, and Which Is Right for You?

    EPA Science Inventory

    this presentation will provide a short review of the explicit and implicit concepts behind most of the currently-used regulatory and diagnostic sampling schemes for lead, such as: random daytime sampling; automated proportional sampler; 30 minute first draw stagnation; Sequential...

  19. Exercise-Associated Collapse in Endurance Events: A Classification System.

    ERIC Educational Resources Information Center

    Roberts, William O.

    1989-01-01

    Describes a classification system devised for exercise-associated collapse in endurance events based on casualties observed at six Twin Cities Marathons. Major diagnostic criteria are body temperature and mental status. Management protocol includes fluid and fuel replacement, temperature correction, and leg cramp treatment. (Author/SM)

  20. Laboratory activities involving transmissible spongiform encephalopathy causing agents

    PubMed Central

    Leunda, Amaya; Van Vaerenbergh, Bernadette; Baldo, Aline; Roels, Stefan; Herman, Philippe

    2013-01-01

    Since the appearance in 1986 of epidemic of bovine spongiform encephalopathy (BSE), a new form of neurological disease in cattle which also affected human beings, many diagnostic and research activities have been performed to develop detection and therapeutic tools. A lot of progress was made in better identifying, understanding and controlling the spread of the disease by appropriate monitoring and control programs in European countries. This paper reviews the recent knowledge on pathogenesis, transmission and persistence outside the host of prion, the causative agent of transmissible spongiform encephalopathies (TSE) in mammals with a particular focus on risk (re)assessment and management of biosafety measures to be implemented in diagnostic and research laboratories in Belgium. Also, in response to the need of an increasing number of European diagnostic laboratories stopping TSE diagnosis due to a decreasing number of TSE cases reported in the last years, decontamination procedures and a protocol for decommissioning TSE diagnostic laboratories is proposed. PMID:24055928

  1. Hotspot mutations in cancer genes may be missed in routine diagnostics due to neighbouring sequence variants.

    PubMed

    Bartels, Stephan; Schipper, Elisa; Hasemeier, Britta; Kreipe, Hans; Lehmann, Ulrich

    2018-05-27

    The detection of hotspot mutations in key cancer genes is now an essential part of the diagnostic work-up in molecular pathology. Nearly all assays for mutation detection involve an amplification step. A second single nucleotide variant (SNV) on the same allele adjacent to a mutational hotspot can interfere with primer binding, leading to unnoticed allele-specific amplification of the wild type allele and thereby false-negative mutation testing. We present two diagnostic cases with false negative sequence results for JAK2 and SRSF2. In both cases mutations would have escaped detection if only one strand of DNA had been analysed. Because many commercially available diagnostic kits rely on the analysis of only one DNA strand they are prone to fail in cases like these. Detailed protocols and quality control measures to prevent corresponding pitfalls are presented. Copyright © 2017. Published by Elsevier Inc.

  2. Semi-Structured Interview Protocol for Constructing Logic Models

    ERIC Educational Resources Information Center

    Gugiu, P. Cristian; Rodriguez-Campos, Liliana

    2007-01-01

    This paper details a semi-structured interview protocol that evaluators can use to develop a logic model of a program's services and outcomes. The protocol presents a series of questions, which evaluators can ask of specific program informants, that are designed to: (1) identify key informants basic background and contextual information, (2)…

  3. Optimizing radiation exposure in screening of body packing: image quality and diagnostic acceptability of an 80 kVp protocol with automated tube current modulation.

    PubMed

    Aissa, Joel; Boos, Johannes; Rubbert, Christian; Caspers, Julian; Schleich, Christoph; Thomas, Christoph; Kröpil, Patric; Antoch, Gerald; Miese, Falk

    2017-06-01

    The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (group A). Forty-nine CT examinations were performed using a standard protocol with a tube voltage of 120 kVp and a fixed tube current time product of 40 mAs (group B). Subjective and objective image quality and visibility of drug packets were assessed. Radiation exposure of both protocols was compared. Contrast-to-noise ratio (group A: 0.56 ± 0.36; group B: 1.13 ± 0.91) and Signal-to-noise ratio (group A: 3.69 ± 0.98; group B: 7.08 ± 2.67) were significantly lower for group A compared to group B (p < 0.001). Subjectively, image quality was decreased for group A compared to group B (2.5 ± 0.8 vs. 1.2 ± 0.4; p < 0.001). Attenuation of body packets was higher with the new protocol (group A: 362.2 ± 70.3 Hounsfield Units (HU); group B: 210.6 ± 60.2 HU; p = 0.005). Volumetric Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) were significantly lower in group A (CTDIvol 2.2 ± 0.9 mGy, DLP 105.7 ± 52.3 mGycm) as compared to group B (CTDIvol 2.7 ± 0.1 mGy, DLP 126.0 ± 9.7 mGycm, p = 0.002 and p = 0.01). The novel 80 kVp CT protocol with ATCM leads to a significant dose reduction compared to a standard CT body packing protocol. The novel protocol led to a diagnostic image quality and cocaine body packets were reliably detected due to the high attenuation.

  4. New diagnostic pathways urgently needed. Protocol of PET Guidance I pilot study: positron emission tomography in suspected cardiac implantable electronic device-related infection.

    PubMed

    Marciniak-Emmons, Marta Barbara; Sterliński, Maciej; Syska, Paweł; Maciąg, Aleksander; Farkowski, Michał Mirosław; Firek, Bohdan; Dziuk, Mirosław; Zając, Dariusz; Pytkowski, Mariusz; Szwed, Hanna

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. We present a protocol of an observational case control clinical trial "Positron Emission Tomography Combined With Computed Tomography (PET CT) in Suspected Cardiac Implantable Electronic Device Infection, a Pilot Study - PET Guidance I" (NCT02196753). The aim of this observational clinical trial is to assess and standardise diagnostic algorithms for CIED infections (lead-dependent infective endocarditis, generator pocket infection, fever of unknown origin) with PET CT in Poland. Study group will consist of 20 patients with initial diagnosis of CIED-related infection paired with a control group of 20 patients with implanted CIEDs, who underwent PET CT due to other non-infectious indications and have no data for infectious process in follow-up. All patients included in the study will undergo standard diagnostic pro-cess. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures; imaging studies: echocardiography: transthoracic (TTE), and, if there are no contraindications transoesophageal, computed tomography scan for pulmonary embolism if indicated; if there are abnormalities in other systems, decisions concerning further diagnostics will be made at the physician's discretion. As well as standard diagnostic procedures, patients will undergo whole body PET CT scan to localise infection or inflammation. Diagnosis and therapeutic decision will be obtained from the Study Committee. Follow-up will be held within six months with control visits at three and six months. During each follow-up visit, all patients will undergo laboratory tests, two blood cultures collected 1 h apart, and TTE. In case of actual clinical suspicion of infective endocarditis or local generator pocket infection, patients will be referred for further diagnostics. Endpoints for the results assessment - primary endpoints are to standardise PET CT in the diagnostic process: sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis made by PET CT; secondary endpoints are: assessment of usefulness of PET CT for detection of remote infective complications (metastatic abscesses, infected pulmonary emboli), incidence of particular localisations of infection, influence of PET CT on therapeutic decision: confirmation or change of decision based on PET CT, safety and complications of diagnostic process of CIED-related infections with PET CT. Evaluation of PET CT use for device-related infections in a case control study may be conclusive and improve diagnostic pathway.

  5. A novel and rapid diagnostic method for discriminating between feces of sika deer and Japanese serow by loop-mediated isothermal amplification.

    PubMed

    Aikawa, T; Horino, S; Ichihara, Y

    2015-08-01

    Severe damages to natural vegetation, agriculture, and forestry caused by overpopulation of sika deer (Cervus nippon) have markedly increased in Japan in recent years. To devise a population management plan of sika deer, information on the distribution and population size of the animal in each region is indispensable. An easy and effective method to obtain this information is to count the fecal pellets in the field. However, the habitat of sika deer in Japan overlaps that of Japanese serow (Capricornis crispus). Additionally, it is difficult to discriminate between the feces of both animals. Here, we present a rapid and precise diagnostic method for discriminating between the feces of sika deer and Japanese serow using loop-mediated isothermal amplification (LAMP) targeting cytochrome b gene in the mitochondrial DNA. Our results showed that the LAMP can discriminate between the feces of sika deer and Japanese serow, and the method is simpler and more sensitive than the conventional molecular diagnostic method. Since LAMP method does not require special skills for molecular biology techniques, even the field researchers who have never done a molecular experiment can easily carry out the protocol. In addition, the entire protocol, from DNA extraction from fecal pellet to identification of species, takes only about 75 min and does not require expensive equipment. Hence, this diagnostic method is simple, fast, and accessible to anyone. As such, the method can be a useful tool to estimate distribution and population size of sika deer.

  6. A direct morphometric comparison of five labeling protocols for multi-atlas driven automatic segmentation of the hippocampus in Alzheimer's disease.

    PubMed

    Nestor, Sean M; Gibson, Erin; Gao, Fu-Qiang; Kiss, Alex; Black, Sandra E

    2013-02-01

    Hippocampal volumetry derived from structural MRI is increasingly used to delineate regions of interest for functional measurements, assess efficacy in therapeutic trials of Alzheimer's disease (AD) and has been endorsed by the new AD diagnostic guidelines as a radiological marker of disease progression. Unfortunately, morphological heterogeneity in AD can prevent accurate demarcation of the hippocampus. Recent developments in automated volumetry commonly use multi-template fusion driven by expert manual labels, enabling highly accurate and reproducible segmentation in disease and healthy subjects. However, there are several protocols to define the hippocampus anatomically in vivo, and the method used to generate atlases may impact automatic accuracy and sensitivity - particularly in pathologically heterogeneous samples. Here we report a fully automated segmentation technique that provides a robust platform to directly evaluate both technical and biomarker performance in AD among anatomically unique labeling protocols. For the first time we test head-to-head the performance of five common hippocampal labeling protocols for multi-atlas based segmentation, using both the Sunnybrook Longitudinal Dementia Study and the entire Alzheimer's Disease Neuroimaging Initiative 1 (ADNI-1) baseline and 24-month dataset. We based these atlas libraries on the protocols of (Haller et al., 1997; Killiany et al., 1993; Malykhin et al., 2007; Pantel et al., 2000; Pruessner et al., 2000), and a single operator performed all manual tracings to generate de facto "ground truth" labels. All methods distinguished between normal elders, mild cognitive impairment (MCI), and AD in the expected directions, and showed comparable correlations with measures of episodic memory performance. Only more inclusive protocols distinguished between stable MCI and MCI-to-AD converters, and had slightly better associations with episodic memory. Moreover, we demonstrate that protocols including more posterior anatomy and dorsal white matter compartments furnish the best voxel-overlap accuracies (Dice Similarity Coefficient=0.87-0.89), compared to expert manual tracings, and achieve the smallest sample sizes required to power clinical trials in MCI and AD. The greatest distribution of errors was localized to the caudal hippocampus and the alveus-fimbria compartment when these regions were excluded. The definition of the medial body did not significantly alter accuracy among more comprehensive protocols. Voxel-overlap accuracies between automatic and manual labels were lower for the more pathologically heterogeneous Sunnybrook study in comparison to the ADNI-1 sample. Finally, accuracy among protocols appears to significantly differ the most in AD subjects compared to MCI and normal elders. Together, these results suggest that selection of a candidate protocol for fully automatic multi-template based segmentation in AD can influence both segmentation accuracy when compared to expert manual labels and performance as a biomarker in MCI and AD. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. A Direct Morphometric Comparison of Five Labeling Protocols for Multi-Atlas Driven Automatic Segmentation of the Hippocampus in Alzheimer’s Disease

    PubMed Central

    Nestor, Sean M.; Gibson, Erin; Gao, Fu-Qiang; Kiss, Alex; Black, Sandra E.

    2012-01-01

    Hippocampal volumetry derived from structural MRI is increasingly used to delineate regions of interest for functional measurements, assess efficacy in therapeutic trials of Alzheimer’s disease (AD) and has been endorsed by the new AD diagnostic guidelines as a radiological marker of disease progression. Unfortunately, morphological heterogeneity in AD can prevent accurate demarcation of the hippocampus. Recent developments in automated volumetry commonly use multitemplate fusion driven by expert manual labels, enabling highly accurate and reproducible segmentation in disease and healthy subjects. However, there are several protocols to define the hippocampus anatomically in vivo, and the method used to generate atlases may impact automatic accuracy and sensitivity – particularly in pathologically heterogeneous samples. Here we report a fully automated segmentation technique that provides a robust platform to directly evaluate both technical and biomarker performance in AD among anatomically unique labeling protocols. For the first time we test head-to-head the performance of five common hippocampal labeling protocols for multi-atlas based segmentation, using both the Sunnybrook Longitudinal Dementia Study and the entire Alzheimer’s Disease Neuroimaging Initiative 1 (ADNI-1) baseline and 24-month dataset. We based these atlas libraries on the protocols of (Haller et al., 1997; Killiany et al., 1993; Malykhin et al., 2007; Pantel et al., 2000; Pruessner et al., 2000), and a single operator performed all manual tracings to generate de facto “ground truth” labels. All methods distinguished between normal elders, mild cognitive impairment (MCI), and AD in the expected directions, and showed comparable correlations with measures of episodic memory performance. Only more inclusive protocols distinguished between stable MCI and MCI-to-AD converters, and had slightly better associations with episodic memory. Moreover, we demonstrate that protocols including more posterior anatomy and dorsal white matter compartments furnish the best voxel-overlap accuracies (Dice Similarity Coefficient = 0.87–0.89), compared to expert manual tracings, and achieve the smallest sample sizes required to power clinical trials in MCI and AD. The greatest distribution of errors was localized to the caudal hippocampus and alveus-fimbria compartment when these regions were excluded. The definition of the medial body did not significantly alter accuracy among more comprehensive protocols. Voxel-overlap accuracies between automatic and manual labels were lower for the more pathologically heterogeneous Sunnybrook study in comparison to the ADNI-1 sample. Finally, accuracy among protocols appears to significantly differ the most in AD subjects compared to MCI and normal elders. Together, these results suggest that selection of a candidate protocol for fully automatic multi-template based segmentation in AD can influence both segmentation accuracy when compared to expert manual labels and performance as a biomarker in MCI and AD. PMID:23142652

  8. Structural and biomechanical changes in shoulders of junior javelin throwers: a comprehensive evaluation as a proof of concept for a preventive exercise protocol.

    PubMed

    Beitzel, Knut; Zandt, Julia F; Buchmann, Stefan; Beitzel, Kirsten I; Schwirtz, Ansgar; Imhoff, Andreas B; Brucker, Peter U

    2016-06-01

    The purpose of this study was to develop a preventive exercise protocol based on structural and functional changes present in shoulder joints of young throwing athletes. As a proof of concept, these changes were previously evaluated in a cross-section of high-performance junior javelin throwers. Thirteen members of the German and Bavarian junior javelin squad (mean age 17.5 ± 0.8 years) completed a systematic clinical examination, shoulder range of motion (ROM) measurement, and were scored with standardized clinical tools. 3.0 tesla magnetic resonance imaging (MRI) was conducted on both shoulders. Bilateral three-dimensional analysis of the scapulothoracic motion during multiplanar humeral elevation and isokinetic strength testing of the shoulder internal and external rotators was accomplished. Based on the findings, a preventive exercise protocol was confirmed. Dominant internal ROM was significantly decreased (dominant 48° ± 20° vs. non-dominant 57° ± 19°; P = 0.006) and dominant external ROM increased (dominant 117° ± 15° vs. non-dominant 107° ± 10°; P = 0.008). MRI revealed posterosuperior intraosseous cysts of the humeral head with a size larger than >3 mm in 69 % of the dominant shoulders and only in 15 % in the non-dominant shoulders. Motion analysis of the static scapular resting position was significantly different between dominant and non-dominant sides regarding anterior tilt (dominant > non-dominant, mean difference 4.2°, P = 0.010) and retraction (dominant > non-dominant, mean difference 2.4°, P = 0.038). Dominant scapular anterior tilt during flexion and abduction was significantly increased (-4.3°, P = 0.006; -3.4°, P = 0.046). Dominant retraction was significantly increased during abduction (-2.3°, P = 0.040). Isokinetic outcome parameters presented nonsignificant bilateral differences. Elite junior javelin throwers already present structural (humeral intraosseous cysts) and biomechanical changes (ROM deficits and asymmetric scapulothoracic motion patterns), even if they have no history of major shoulder pain or injury. A novel exercise protocol was developed in order to address the complex of alterations in a comprehensive way. Preventive diagnostics in combination with a systematic all-year preventive exercise intervention might be one option to detect and control risk factors of a symptomatic throwing shoulder at an early stage. IV.

  9. Computed Tomography of the Normal Bovine Tarsus.

    PubMed

    Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K

    2016-12-01

    The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20 o C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.

  10. Validating DNA barcodes: A non-destructive extraction protocol enables simultaneous vouchering of DNA and morphological vouchers

    USDA-ARS?s Scientific Manuscript database

    Morphology-based keys support accurate identification of many taxa. However, identification can be difficult for taxa that are not well studied, very small, members of cryptic species complexes, or represented by immature stages. For such cases, DNA barcodes may provide diagnostic characters. Ecolog...

  11. Toward a Best-Practice Protocol for Assessment of Sensory Features in ASD

    ERIC Educational Resources Information Center

    Schaaf, Roseann C.; Lane, Alison E.

    2015-01-01

    Sensory difficulties are a commonly occurring feature of autism spectrum disorders and are now included as one manifestation of the "restricted, repetitive patterns of behavior, interests, or activities" diagnostic criteria of the DSM5 necessitating guidelines for comprehensive assessment of these features. To facilitate the development…

  12. Ultrasound and the IRB

    ERIC Educational Resources Information Center

    Epstein, Melissa A.

    2005-01-01

    The purpose of this paper is to assist researchers in writing their research protocols and subject consent forms so that both the Institutional Review Board (IRB) and subjects are assured of the minimal risk associated with diagnostic B-scan ultrasound as it is used in speech research. There have been numerous epidemiological studies on fetal…

  13. Smart Sensors Gather Information for Machine Diagnostics

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Stennis Space Center was interested in using smart sensors to monitor components on test stands and avert equipment failures. Partnering with St. Paul, Minnesota-based Lion Precision through a Cooperative Agreement, the team developed a smart sensor and the associated communication protocols. The same sensor is now commercially available for manufacturing.

  14. Développement d’un programme multidisciplinaire de diagnostic de l’adrénoleucodystrophie liée à l’X au Maroc: résultats de la mise en œuvre du programme de diagnostic clinique et biologique

    PubMed Central

    Benjelloun, Fatima-Zohra Madani; Chabraoui, Layachi; Kriouile, Yamna

    2017-01-01

    Introduction L'adrénoleucodystrophie liée à l'X (X-ALD) est une maladie neurodégénérative sévère, due à des mutations du gène ABCD1. Elle se manifeste par une atteinte du système nerveux central et périphérique, une insuffisance surrénalienne et une atteinte des testicules chez le garçon. Son diagnostic repose sur le dosage des Acides Gras à Très Longue Chaine. Le diagnostic précoce est d'une grande importance puisque il définit l'accessibilité aux traitements selon le stage de la maladie. Méthodes Nous avons mis en place un programme de diagnostic de l'X-ALD au Maroc au niveau de l'Hôpital d'enfants et du Laboratoire centrale des maladies héréditaires et du métabolisme de Rabat. Le programme s'articule sur trois axes à savoir : le recrutement des patients, le diagnostic et la sensibilisation. Le diagnostic s'effectue selon trois protocoles : un protocole pour les cas symptomatiques, un deuxième pour les cas asymptomatiques et un troisième pour les femmes hétérozygotes. Résultats Durant trois ans après la mise en place de notre programme de diagnostic de l'Adrénoleucodystrophie liée à l'X, nous avons diagnostiqué la maladie chez sept familles, avec neuf garçons et trois femmes hétérozygotes. Tous les enfants diagnostiqués présentaient la forme cérébrale démyélinisante. Toutes les femmes hétérozygotes étaient asymptomatiques. Une prise en charge thérapeutique a été mise place selon la symptomatologie de chaque cas. Conclusion l'X-ALD est une maladie rare. Notre programme de diagnostique a permis de diagnostiquer un nombre important de cas, ce qui montre son importance. Les compagnes de sensibilisation auprès des professionnels permettront de mieux comprendre la maladie et mieux la diagnostiquer et ainsi donner accès à un nombre plus élevé de patients. PMID:29599883

  15. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    PubMed

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83-0.89)) and functional reference standards (AUC 0.88(0.84-0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .

  16. Design of the Protocol Processor for the ROBUS-2 Communication System

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Miner, Paul S.

    2005-01-01

    The ROBUS-2 Protocol Processor (RPP) is a custom-designed hardware component implementing the functionality of the ROBUS-2 fault-tolerant communication system. The Reliable Optical Bus (ROBUS) is the core communication system of the Scalable Processor-Independent Design for Enhanced Reliability (SPIDER), a general-purpose fault tolerant integrated modular architecture currently under development at NASA Langley Research Center. ROBUS is a time-division multiple access (TDMA) broadcast communication system with medium access control by means of time-indexed communication schedule. ROBUS-2 is a developmental version of the ROBUS providing guaranteed fault-tolerant services to the attached processing elements (PEs), in the presence of a bounded number of faults. These services include message broadcast (Byzantine Agreement), dynamic communication schedule update, time reference (clock synchronization), and distributed diagnosis (group membership). ROBUS also features fault-tolerant startup and restart capabilities. ROBUS-2 tolerates internal as well as PE faults, and incorporates a dynamic self-reconfiguration capability driven by the internal diagnostic system. ROBUS consists of RPPs connected to each other by a lower-level physical communication network. The RPP has a pipelined architecture and the design is parameterized in the behavioral and structural domains. The design of the RPP enables the bus to achieve a PE-message throughput that approaches the available bandwidth at the physical layer.

  17. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    PubMed

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to the clinical audit programme and the IAEA clinical audit protocol.

  18. Modeling Structure and Dynamics of Protein Complexes with SAXS Profiles

    PubMed Central

    Schneidman-Duhovny, Dina; Hammel, Michal

    2018-01-01

    Small-angle X-ray scattering (SAXS) is an increasingly common and useful technique for structural characterization of molecules in solution. A SAXS experiment determines the scattering intensity of a molecule as a function of spatial frequency, termed SAXS profile. SAXS profiles can be utilized in a variety of molecular modeling applications, such as comparing solution and crystal structures, structural characterization of flexible proteins, assembly of multi-protein complexes, and modeling of missing regions in the high-resolution structure. Here, we describe protocols for modeling atomic structures based on SAXS profiles. The first protocol is for comparing solution and crystal structures including modeling of missing regions and determination of the oligomeric state. The second protocol performs multi-state modeling by finding a set of conformations and their weights that fit the SAXS profile starting from a single-input structure. The third protocol is for protein-protein docking based on the SAXS profile of the complex. We describe the underlying software, followed by demonstrating their application on interleukin 33 (IL33) with its primary receptor ST2 and DNA ligase IV-XRCC4 complex. PMID:29605933

  19. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    PubMed

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR.

    PubMed

    Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W

    2015-04-01

    The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  1. Applying an Empirical Hydropathic Forcefield in Refinement May Improve Low-Resolution Protein X-Ray Crystal Structures

    PubMed Central

    Koparde, Vishal N.; Scarsdale, J. Neel; Kellogg, Glen E.

    2011-01-01

    Background The quality of X-ray crystallographic models for biomacromolecules refined from data obtained at high-resolution is assured by the data itself. However, at low-resolution, >3.0 Å, additional information is supplied by a forcefield coupled with an associated refinement protocol. These resulting structures are often of lower quality and thus unsuitable for downstream activities like structure-based drug discovery. Methodology An X-ray crystallography refinement protocol that enhances standard methodology by incorporating energy terms from the HINT (Hydropathic INTeractions) empirical forcefield is described. This protocol was tested by refining synthetic low-resolution structural data derived from 25 diverse high-resolution structures, and referencing the resulting models to these structures. The models were also evaluated with global structural quality metrics, e.g., Ramachandran score and MolProbity clashscore. Three additional structures, for which only low-resolution data are available, were also re-refined with this methodology. Results The enhanced refinement protocol is most beneficial for reflection data at resolutions of 3.0 Å or worse. At the low-resolution limit, ≥4.0 Å, the new protocol generated models with Cα positions that have RMSDs that are 0.18 Å more similar to the reference high-resolution structure, Ramachandran scores improved by 13%, and clashscores improved by 51%, all in comparison to models generated with the standard refinement protocol. The hydropathic forcefield terms are at least as effective as Coulombic electrostatic terms in maintaining polar interaction networks, and significantly more effective in maintaining hydrophobic networks, as synthetic resolution is decremented. Even at resolutions ≥4.0 Å, these latter networks are generally native-like, as measured with a hydropathic interactions scoring tool. PMID:21246043

  2. Mapping of Schistosomiasis and Soil-Transmitted Helminths in Namibia: The First Large-Scale Protocol to Formally Include Rapid Diagnostic Tests.

    PubMed

    Sousa-Figueiredo, José Carlos; Stanton, Michelle C; Katokele, Stark; Arinaitwe, Moses; Adriko, Moses; Balfour, Lexi; Reiff, Mark; Lancaster, Warren; Noden, Bruce H; Bock, Ronnie; Stothard, J Russell

    2015-01-01

    Namibia is now ready to begin mass drug administration of praziquantel and albendazole against schistosomiasis and soil-transmitted helminths, respectively. Although historical data identifies areas of transmission of these neglected tropical diseases (NTDs), there is a need to update epidemiological data. For this reason, Namibia adopted a new protocol for mapping of schistosomiasis and geohelminths, formally integrating rapid diagnostic tests (RDTs) for infections and morbidity. In this article, we explain the protocol in detail, and introduce the concept of 'mapping resolution', as well as present results and treatment recommendations for northern Namibia. This new protocol allowed a large sample to be surveyed (N = 17,896 children from 299 schools) at relatively low cost (7 USD per person mapped) and very quickly (28 working days). All children were analysed by RDTs, but only a sub-sample was also diagnosed by light microscopy. Overall prevalence of schistosomiasis in the surveyed areas was 9.0%, highly associated with poorer access to potable water (OR = 1.5, P<0.001) and defective (OR = 1.2, P<0.001) or absent sanitation infrastructure (OR = 2.0, P<0.001). Overall prevalence of geohelminths, more particularly hookworm infection, was 12.2%, highly associated with presence of faecal occult blood (OR = 1.9, P<0.001). Prevalence maps were produced and hot spots identified to better guide the national programme in drug administration, as well as targeted improvements in water, sanitation and hygiene. The RDTs employed (circulating cathodic antigen and microhaematuria for Schistosoma mansoni and S. haematobium, respectively) performed well, with sensitivities above 80% and specificities above 95%. This protocol is cost-effective and sensitive to budget limitations and the potential economic and logistical strains placed on the national Ministries of Health. Here we present a high resolution map of disease prevalence levels, and treatment regimens are recommended.

  3. Diagnostic, treatment, and prevention protocols for canine heartworm infection in animal sheltering agencies.

    PubMed

    Colby, Kathleen N; Levy, Julie K; Dunn, Kiri F; Michaud, Rachel I

    2011-03-22

    The high prevalence of heartworm infection in shelter dogs creates a dilemma for shelter managers, who frequently operate with insufficient funding, staffing, and expertise to comply with heartworm guidelines developed for owned pet dogs. The purpose of this study was to survey canine heartworm management protocols used by 504 animal sheltering agencies in the endemic states of Alabama, Florida, Georgia, and Mississippi. Open-admission shelters, which tended to be larger and more likely to perform animal control functions, were less likely (41%) to test all adult dogs than were limited-admission shelters (80%), which tended to be smaller non-profit humane agencies, and foster programs (98%) based out of private residences. Open-admission shelters were more likely to euthanize infected dogs (27%) or to release them without treatment (39%), whereas limited-admission shelters and foster programs were more likely to provide adulticide therapy (82% and 89%, respectively). Of the 319 agencies that treated infections, 44% primarily used a standard two-dose melarsomine protocol, and 35% primarily used a three-dose split-treatment melarsomine protocol. Long-term low-dose ivermectin was the most common treatment used in 22% of agencies. Open-admission shelters were less likely (35%) to provide preventive medications for all dogs than were limited-admission shelters (82%) and foster programs (97%). More agencies used preventives labeled for monthly use in dogs (60%) than ivermectin products labeled for livestock (38%). The most common reason diagnostic testing and preventive medication was not provided was cost. These results indicate a lack of protocol uniformity among agencies and insufficient resources to identify, treat, and prevent infection. Sheltering agencies and companion animal health industries should develop guidelines that are feasible for use in sheltering agencies and provide improved access to preventive and treatment strategies for management of Dirofilaria immitis. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Mapping of Schistosomiasis and Soil-Transmitted Helminths in Namibia: The First Large-Scale Protocol to Formally Include Rapid Diagnostic Tests

    PubMed Central

    Sousa-Figueiredo, José Carlos; Stanton, Michelle C.; Katokele, Stark; Arinaitwe, Moses; Adriko, Moses; Balfour, Lexi; Reiff, Mark; Lancaster, Warren; Noden, Bruce H.; Bock, Ronnie; Stothard, J. Russell

    2015-01-01

    Background Namibia is now ready to begin mass drug administration of praziquantel and albendazole against schistosomiasis and soil-transmitted helminths, respectively. Although historical data identifies areas of transmission of these neglected tropical diseases (NTDs), there is a need to update epidemiological data. For this reason, Namibia adopted a new protocol for mapping of schistosomiasis and geohelminths, formally integrating rapid diagnostic tests (RDTs) for infections and morbidity. In this article, we explain the protocol in detail, and introduce the concept of ‘mapping resolution’, as well as present results and treatment recommendations for northern Namibia. Methods/Findings/Interpretation This new protocol allowed a large sample to be surveyed (N = 17 896 children from 299 schools) at relatively low cost (7 USD per person mapped) and very quickly (28 working days). All children were analysed by RDTs, but only a sub-sample was also diagnosed by light microscopy. Overall prevalence of schistosomiasis in the surveyed areas was 9.0%, highly associated with poorer access to potable water (OR = 1.5, P<0.001) and defective (OR = 1.2, P<0.001) or absent sanitation infrastructure (OR = 2.0, P<0.001). Overall prevalence of geohelminths, more particularly hookworm infection, was 12.2%, highly associated with presence of faecal occult blood (OR = 1.9, P<0.001). Prevalence maps were produced and hot spots identified to better guide the national programme in drug administration, as well as targeted improvements in water, sanitation and hygiene. The RDTs employed (circulating cathodic antigen and microhaematuria for Schistosoma mansoni and S. haematobium, respectively) performed well, with sensitivities above 80% and specificities above 95%. Conclusion/Significance This protocol is cost-effective and sensitive to budget limitations and the potential economic and logistical strains placed on the national Ministries of Health. Here we present a high resolution map of disease prevalence levels, and treatment regimens are recommended. PMID:26196386

  5. Very low intravenous contrast volume protocol for computed tomography angiography providing comprehensive cardiac and vascular assessment prior to transcatheter aortic valve replacement in patients with chronic kidney disease.

    PubMed

    Pulerwitz, Todd C; Khalique, Omar K; Nazif, Tamim N; Rozenshtein, Anna; Pearson, Gregory D N; Hahn, Rebecca T; Vahl, Torsten P; Kodali, Susheel K; George, Isaac; Leon, Martin B; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  6. Compatible topologies and parameters for NMR structure determination of carbohydrates by simulated annealing.

    PubMed

    Feng, Yingang

    2017-01-01

    The use of NMR methods to determine the three-dimensional structures of carbohydrates and glycoproteins is still challenging, in part because of the lack of standard protocols. In order to increase the convenience of structure determination, the topology and parameter files for carbohydrates in the program Crystallography & NMR System (CNS) were investigated and new files were developed to be compatible with the standard simulated annealing protocols for proteins and nucleic acids. Recalculating the published structures of protein-carbohydrate complexes and glycosylated proteins demonstrates that the results are comparable to the published structures which employed more complex procedures for structure calculation. Integrating the new carbohydrate parameters into the standard structure calculation protocol will facilitate three-dimensional structural study of carbohydrates and glycosylated proteins by NMR spectroscopy.

  7. Compatible topologies and parameters for NMR structure determination of carbohydrates by simulated annealing

    PubMed Central

    2017-01-01

    The use of NMR methods to determine the three-dimensional structures of carbohydrates and glycoproteins is still challenging, in part because of the lack of standard protocols. In order to increase the convenience of structure determination, the topology and parameter files for carbohydrates in the program Crystallography & NMR System (CNS) were investigated and new files were developed to be compatible with the standard simulated annealing protocols for proteins and nucleic acids. Recalculating the published structures of protein-carbohydrate complexes and glycosylated proteins demonstrates that the results are comparable to the published structures which employed more complex procedures for structure calculation. Integrating the new carbohydrate parameters into the standard structure calculation protocol will facilitate three-dimensional structural study of carbohydrates and glycosylated proteins by NMR spectroscopy. PMID:29232406

  8. Construction of robust dynamic genome-scale metabolic model structures of Saccharomyces cerevisiae through iterative re-parameterization.

    PubMed

    Sánchez, Benjamín J; Pérez-Correa, José R; Agosin, Eduardo

    2014-09-01

    Dynamic flux balance analysis (dFBA) has been widely employed in metabolic engineering to predict the effect of genetic modifications and environmental conditions in the cell׳s metabolism during dynamic cultures. However, the importance of the model parameters used in these methodologies has not been properly addressed. Here, we present a novel and simple procedure to identify dFBA parameters that are relevant for model calibration. The procedure uses metaheuristic optimization and pre/post-regression diagnostics, fixing iteratively the model parameters that do not have a significant role. We evaluated this protocol in a Saccharomyces cerevisiae dFBA framework calibrated for aerobic fed-batch and anaerobic batch cultivations. The model structures achieved have only significant, sensitive and uncorrelated parameters and are able to calibrate different experimental data. We show that consumption, suboptimal growth and production rates are more useful for calibrating dynamic S. cerevisiae metabolic models than Boolean gene expression rules, biomass requirements and ATP maintenance. Copyright © 2014 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  9. Experiences in supporting the structured collection of cancer nanotechnology data using caNanoLab

    PubMed Central

    Gaheen, Sharon; Lijowski, Michal; Heiskanen, Mervi; Klemm, Juli

    2015-01-01

    Summary The cancer Nanotechnology Laboratory (caNanoLab) data portal is an online nanomaterial database that allows users to submit and retrieve information on well-characterized nanomaterials, including composition, in vitro and in vivo experimental characterizations, experimental protocols, and related publications. Initiated in 2006, caNanoLab serves as an established resource with an infrastructure supporting the structured collection of nanotechnology data to address the needs of the cancer biomedical and nanotechnology communities. The portal contains over 1,000 curated nanomaterial data records that are publicly accessible for review, comparison, and re-use, with the ultimate goal of accelerating the translation of nanotechnology-based cancer therapeutics, diagnostics, and imaging agents to the clinic. In this paper, we will discuss challenges associated with developing a nanomaterial database and recognized needs for nanotechnology data curation and sharing in the biomedical research community. We will also describe the latest version of caNanoLab, caNanoLab 2.0, which includes enhancements and new features to improve usability such as personalized views of data and enhanced search and navigation. PMID:26425409

  10. Estimating the strength of bone using linear response

    NASA Astrophysics Data System (ADS)

    Gunaratne, Gemunu H.

    2002-12-01

    Accurate diagnostic tools are required for effective management of osteoporosis; one method to identify additional diagnostics is to search for observable consequences of bone loss. An analysis of a model system is used to show that weakening of a bone is accompanied by a reduction of the fraction of the bone that participates in load transmission. On the basis of this observation, it is argued that the ratio Γ of linear responses of a network to dc and high-frequency ac driving can be used as a surrogate for their strength. Protocols needed to obtain Γ for bone samples are discussed.

  11. A systematic review of suggestive seizure induction for the diagnosis of psychogenic nonepileptic seizures.

    PubMed

    Popkirov, Stoyan; Grönheit, Wenke; Wellmer, Jörg

    2015-09-01

    Suggestive seizure induction is a widely used method for diagnosing psychogenic nonepileptic seizures (PNES). Despite seven decades of multidisciplinary research, however, there is still no unified protocol, no definitive agreement on the ethical framework and no consensus on diagnostic utility. This systematic review surveys the evidence at hand and addresses clinically relevant aspects of suggestive seizure induction. In addition to its use for facilitating the diagnostic process, its mechanism of action and utility in elucidating the psychopathology of PNES will be discussed. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  12. Diagnosis Protocol of Stomach Distemperament for Clinical Practice in Iranian Traditional Medicine: A Narrative Review

    PubMed Central

    ALIZADEH, Mahdi; KHADEM, Ebrahim; ALIASL, Jale

    2017-01-01

    Background: In Iranian traditional medicine (ITM) stomach is the important organ in the body. Its disorders can affect other organs such as liver, heart and also can cause depression. Stomach distemperaments can cause some disorders. The purpose of this study was to provide a diagnostic method of stomach distemperament for clinical practice. Methods: In this study authoritative ITM books such as Canon of Avicenna, Zakhirah-E-Kharazm Shahi by Hakim Esmail Jorjani, Kamel al-Sina’ah al-Tibbiyah by Ali ibn al-‘Abbas al-Majusi were assessed and symptoms and signs of stomach distemperament were collected. Results: Stomach has some normal temperament. The imbalance in temperament and humor can cause distemperments. There are 12 types of stomach distemperament and based on symptoms and signs a primary protocol is designed for diagnosis of stomach distemperament. Conclusion: There is no available guideline for gastric distemperamet diagnosis protocol. As a result, the presented protocol should be considered for use in clinical practice. PMID:28845397

  13. Spectral-domain Optical Coherence Tomography in Manifest Glaucoma: Its Additive Role in Structural Diagnosis.

    PubMed

    Kim, Ko Eun; Oh, Sohee; Jeoung, Jin Wook; Suh, Min Hee; Seo, Je Hyun; Kim, Martha; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan

    2016-11-01

    To investigate the additive role of spectral-domain optical coherence tomography (SDOCT) in the structural diagnosis in glaucoma. Reliability and validity analysis. Structural examinations from 109 eyes of 109 healthy individuals and 151 eyes of 151 glaucoma patients with different severities were included. Four structural-diagnostic examination sets were prepared using stereo-optic disc photography (SDP), red-free retinal nerve fiber layer photography (RNFLP), and SDOCT: (1) SDP (S), (2) SDP and SDOCT (SO), (3) SDP and RNFLP (SR), and (4) SDP, RNFLP, and SDOCT (SRO). Five glaucoma specialists were instructed to classify subjects as normal or glaucoma using each of the 4 diagnostic sets in the order S, SO, SR, and SRO, with a 1-month interval. The interobserver agreement was evaluated using kappa (κ) statistics. The additive effect of SDOCT on the diagnostic performance of the specialists was evaluated using the generalized estimating equation. Five glaucoma specialists showed an excellent level of interobserver agreement on the diagnostic assessments based on the 4 sets. In the comparison of the collective diagnostic performance of the specialists, addition of SDOCT to SDP showed an approximately 2-fold significant increase in the diagnostic accuracy. Adding SDOCT to SDP significantly enhanced the specialists' structural-diagnostic ability with respect to the moderate glaucoma, though not mild or advanced glaucoma. SDOCT significantly enhanced the diagnostic accuracy of the glaucoma specialists' performance, showing its additive diagnostic value in judging glaucomatous structural damage, especially in the moderate stage of glaucoma. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Technical innovation changes standard radiographic protocols in veterinary medicine: is it necessary to obtain two dorsoproximal-palmarodistal oblique views of the equine foot when using computerised radiography systems?

    PubMed

    Whitlock, J; Dixon, J; Sherlock, C; Tucker, R; Bolt, D M; Weller, R

    2016-05-21

    Since the 1950s, veterinary practitioners have included two separate dorsoproximal-palmarodistal oblique (DPr-PaDiO) radiographs as part of a standard series of the equine foot. One image is obtained to visualise the distal phalanx and the other to visualise the navicular bone. However, rapid development of computed radiography and digital radiography and their post-processing capabilities could mean that this practice is no longer required. The aim of this study was to determine differences in perceived image quality between DPr-PaDiO radiographs that were acquired with a computerised radiography system with exposures, centring and collimation recommended for the navicular bone versus images acquired for the distal phalanx but were subsequently manipulated post-acquisition to highlight the navicular bone. Thirty images were presented to four clinicians for quality assessment and graded using a 1-3 scale (1=textbook quality, 2=diagnostic quality, 3=non-diagnostic image). No significant difference in diagnostic quality was found between the original navicular bone images and the manipulated distal phalanx images. This finding suggests that a single DPr-PaDiO image of the distal phalanx is sufficient for an equine foot radiographic series, with appropriate post-processing and manipulation. This change in protocol will result in reduced radiographic study time and decreased patient/personnel radiation exposure. British Veterinary Association.

  15. [Work-related musculoskeletal diseases: experience of INAIL of the Apulia region 1998-2001].

    PubMed

    Allamprese, P; Attimonelli, R; Gigante, M R; Soleo, L

    2005-01-01

    The insurance recognition of Work related Muscolo Skeletal Disorders (WMSDs) has been introduced in Italy by the sentences of Constitutional Court n. 179/1988 and 208/1988. Afterwards the National Insurance Institute against work injuries (INAIL) tried to make homogeneous, in the different INAIL regional Departments, the diagnostic protocol of the work related illness associated with repetitive manual activities. Since 1998, indeed, a clinical diagnostic protocol has been used in the different departments. This report describes the Work related Muscolo Skeletal Disorders submitted to the Apulian INAIL Regional Direction in the period 1998-2001. Among 84 cases of disease reported to the Regional Direction, 21 were recognised as professional illness, the most part of which in workers employed in services sector and mining activities. The most represented disease was carpal tunnel syndrome and it was more recurrent in men than in women, in which the first symptoms were earlier than in men. The most represented risk factor, both in reported and in recognised cases, was the presence of repetitive working movements of the upper extremities, or the combination of the previous one with other risk factors such as high frequency of working activities, postural risk, strength demand, vibrations, climatic conditions. The development of specific diagnostic criteria, the detailed job analysis and the use of specific questionnaires seem to be the main elements for the WMSDs diagnosis and for the recognition of their professional etiology.

  16. Detection and molecular characterization of Cryptosporidium spp. in captive canaries (Serinus canaria) using different diagnostic methods.

    PubMed

    Camargo, Vinícius da Silva; Santana, Bruna Nicoleti; Ferrari, Elis Domingos; Nakamura, Alex Akira; Nagata, Walter Bertequini; Nardi, Ana Rita Moraes; Meireles, Marcelo Vasconcelos

    2018-01-01

    This study used several diagnostic methods to examine the occurrence of and molecularly characterize Cryptosporidium spp. in captive canaries (Serinus canaria) in southern and southeastern Brazil. A total of 498 fecal samples were purified by centrifugal-flotation using Sheather's solution. Cryptosporidium spp. diagnosis was performed using three diagnostic methods: malachite green negative staining, nested PCR targeting the 18S rRNA gene, followed by sequencing the amplified fragments, and duplex real-time PCR targeting the 18S rRNA specific to detect Cryptosporidium galli and Cryptosporidium avian genotype III. The overall positivity for Cryptosporidium spp. (total samples positive in at least one protocol) from the microscopic analysis, nested PCR and duplex real-time PCR protocol results was 13.3% (66/498). The positivity rates were 2.0% (10/498) and 4.6% (23/498) for Cryptosporidium spp. by microscopy and nested PCR, respectively. Sequencing of 20 samples amplified by nested PCR identified C. galli (3.0%; 15/498), Cryptosporidium avian genotype I (0.8%; 4/498) and Cryptosporidium avium (0.2%; 1/498). Duplex real-time PCR revealed a positivity of 7.8% (39/498) for C. galli and 2.4% (12/498) for avian genotype III. Malachite green negative staining differed significantly from nested PCR in detecting Cryptosporidium spp. Duplex real-time PCR was more sensitive than nested PCR/sequencing for detecting gastric Cryptosporidium in canaries.

  17. Prevalence and Phenotype of Childhood Apraxia of Speech In Youth with Galactosemia

    PubMed Central

    Shriberg, Lawrence D.; Potter, Nancy L.; Strand, Edythe A.

    2010-01-01

    Purpose We address the hypothesis that the severe and persistent speech disorder reported in persons with galactosemia meets contemporary diagnostic criteria for Childhood Apraxia of Speech (CAS). A positive finding for CAS in this rare metabolic disorder has the potential to impact treatment of persons with galactosemia and inform explanatory perspectives on CAS in neurological, neurodevelopmental, and idiopathic contexts. Method Thirty-three youth with galactosemia and significant prior or persistent speech sound disorder were assessed in their homes in 17 states. Participants completed a protocol yielding information on their cognitive, structural, sensorimotor, language, speech, prosody, and voice status and function. Results Eight of the 33 participants (24%) met contemporary diagnostic criteria for CAS. Two participants, one of whom was among the 8 with CAS, met criteria for ataxic or hyperkinetic dysarthria. Group-wise findings for the remaining 24 participants are consistent with a classification category termed Motor Speech Disorder-Not Otherwise Specified (MSD-NOS; Shriberg, Fourakis, et al., in press-a). Conclusion We estimate the prevalence of CAS in galactosemia at 18 per hundred, 180 times the estimated risk for idiopathic CAS. Findings support the need to study risk factors for the high occurrence of motor speech disorders in galactosemia, despite early compliant dietary management. PMID:20966389

  18. A Randomized, Placebo-controlled Trial of Digestive Enzymes in Children with Autism Spectrum Disorders.

    PubMed

    Saad, Khaled; Eltayeb, Azza A; Mohamad, Ismail L; Al-Atram, Abdulrahman A; Elserogy, Yasser; Bjørklund, Geir; El-Houfey, Amira A; Nicholson, Bubba

    2015-08-31

    There is growing evidence for a gut-brain connection associated with autism spectrum disorders (ASDs). This suggests a potential benefit from introduced digestive enzymes for children with ASD. We performed a double-blind, randomized clinical trial on 101 children with ASD (82 boys and 19 girls) aged from 3 to 9 years. ASD patients were diagnosed according to the Diagnostic and Statistical Manual of Mental Disorders 4th edition, text revision (DSM-IV-TR) diagnostic criteria. Structured interviews of at least one hour each both with the parents and the child were performed. Later on, another two hours-session was conducted applying the Childhood Autism Rating Scale (CARS). ASD patients were randomized to receive digestive enzymes or placebo. The ASD group receiving digestive enzyme therapy for 3 months had significant improvement in emotional response, general impression autistic score, general behavior and gastrointestinal symptoms. Our study demonstrated the usefulness of digestive enzyme in our population of ASD patients. Digestive enzymes are inexpensive, readily available, have an excellent safety profile, and have mildly beneficial effects in ASD patients. Depending on the parameter measured in our study, we propose digestive enzymes for managing symptoms of ASD. Digestive enzyme therapy may be a possible option in treatment protocols for ASD in the future.

  19. Low-tube voltage 100 kVp MDCT in screening of cocaine body packing: image quality and radiation dose compared to 120 kVp MDCT.

    PubMed

    Aissa, Joel; Rubbert, Christian; Boos, Johannes; Schleich, Christoph; Thomas, Christoph; Kröpil, Patric; Antoch, Gerald; Miese, Falk

    2015-10-01

    The aim of this study was to evaluate the impact of a reduced tube potential (100 kVp) for non-enhanced abdominal low-dose CT on radiation dose and image quality (IQ) in the detection of body packing. This retrospective study was approved by the local research ethics committee of our clinic. From March 2012 to July 2014, 99 subjects were referred to our institute with suspected body packing. 50 CT scans were performed using a 120 kVp protocol (group A), and 49 CTs were performed using a low-dose protocol with a tube voltage of 100 kVp (group B). Subjective and objective IQ were assessed. DLP and CTDIvol were analyzed. All examinations were of diagnostic IQ. Objective IQ was not significantly different between the 120 kVp and 100 kVp protocol. Mean density of solid and liquid body packets was 210 ± 60.2 HU at 120 kVp and 250.6 ± 29.7 HU at 100 kVp. Radiation dose was significantly lower in group B as compared to group A (p < 0.05). In group A, body packs were detected in 16 (32%) of the 50 patients. In group B, packets were observed in 15 (31%) of 49 patients. Laboratory analysis detected cocaine in all smuggled body packs. Low-tube voltage 100 kVp MDCT with automated tube current modulation in screening of illegal drugs leads to a diagnostic IQ and significant dose reduction compared to 120 kVp low-tube voltage protocols. Despite lower radiation dose, liquid and solid cocaine containers retain high attenuation and are easily detected.

  20. Sample-to-SNP kit: a reliable, easy and fast tool for the detection of HFE p.H63D and p.C282Y variations associated to hereditary hemochromatosis.

    PubMed

    Nielsen, Peter B; Petersen, Maja S; Ystaas, Viviana; Andersen, Rolf V; Hansen, Karin M; Blaabjerg, Vibeke; Refstrup, Mette

    2012-10-01

    Classical hereditary hemochromatosis involves the HFE-gene and diagnostic analysis of the DNA variants HFE p.C282Y (c.845G>A; rs1800562) and HFE p.H63D (c.187C>G; rs1799945). The affected protein alters the iron homeostasis resulting in iron overload in various tissues. The aim of this study was to validate the TaqMan-based Sample-to-SNP protocol for the analysis of the HFE-p.C282Y and p.H63D variants with regard to accuracy, usefulness and reproducibility compared to an existing SNP protocol. The Sample-to-SNP protocol uses an approach where the DNA template is made accessible from a cell lysate followed by TaqMan analysis. Besides the HFE-SNPs other eight SNPs were used as well. These SNPs were: Coagulation factor II-gene F2 c.20210G>A, Coagulation factor V-gene F5 p.R506Q (c.1517G>A; rs121917732), Mitochondria SNP: mt7028 G>A, Mitochondria SNP: mt12308 A>G, Proprotein convertase subtilisin/kexin type 9-gene PCSK9 p.R46L (c.137G>T), Plutathione S-transferase pi 1-gene GSTP1 p.I105V (c313A>G; rs1695), LXR g.-171 A>G, ZNF202 g.-118 G>T. In conclusion the Sample-to-SNP kit proved to be an accurate, reliable, robust, easy to use and rapid TaqMan-based SNP detection protocol, which could be quickly implemented in a routine diagnostic or research facility. Copyright © 2012. Published by Elsevier B.V.

  1. Application of Abbreviated Protocol of Magnetic Resonance Imaging for Breast Cancer Screening in Dense Breast Tissue.

    PubMed

    Chen, Shuang-Qing; Huang, Min; Shen, Yu-Ying; Liu, Chen-Lu; Xu, Chuan-Xiao

    2017-03-01

    The study aimed to evaluate the usefulness of an abbreviated protocol (AP) of magnetic resonance imaging (MRI) in comparison to a full diagnostic protocol (FDP) of MRI in the breast cancer screening with dense breast tissue. There are 478 female participants with dense breast tissue and negative mammography results, who were imaged with MRI using AP and FDP. The AP and FDP images were analyzed separately, and the sensitivity and specificity of breast cancer detection were calculated. The chi-square test and receiver operating characteristics curves were used to assess the breast cancer diagnostic capabilities of the two protocols. Sixteen cases of breast cancer from 478 patients with dense breasts were detected using the FDP method, with pathologic confirmation of nine cases of ductal carcinoma in situ, six cases of invasive ductal carcinoma, and one case of mucinous carcinoma. Fifteen cases of breast cancer were successfully screened using the AP method. The sensitivity showed no obvious significant difference between AP and FDP (χ 2  = 0.592, P = 0.623), but the specificity showed a statistically significant difference (χ 2  = 4.619, P = 0.036). The receiver operating characteristics curves showed high efficacy of both methods in the detection of breast cancer in dense breast tissue (the areas under the curve were 0.931 ± 0.025 and 0.947 ± 0.024, respectively), and the ability to diagnose breast cancer was not statistically significantly different between the two methods. The AP of MRI may improve the detection rate of breast cancer in dense breast tissue, and it may be useful in efficient breast cancer screening. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Diagnostic accuracy of the Bedside Lung Ultrasound in Emergency protocol for the diagnosis of acute respiratory failure in spontaneously breathing patients*,**

    PubMed Central

    Dexheimer, Felippe Leopoldo; de Andrade, Juliana Mara Stormovski; Raupp, Ana Carolina Tabajara; Townsend, Raquel da Silva; Beltrami, Fabiana Gabe; Brisson, Hélène; Lu, Qin; Dalcin, Paulo de Tarso Roth

    2015-01-01

    Objective: Bedside lung ultrasound (LUS) is a noninvasive, readily available imaging modality that can complement clinical evaluation. The Bedside Lung Ultrasound in Emergency (BLUE) protocol has demonstrated a high diagnostic accuracy in patients with acute respiratory failure (ARF). Recently, bedside LUS has been added to the medical training program of our ICU. The aim of this study was to investigate the accuracy of LUS based on the BLUE protocol, when performed by physicians who are not ultrasound experts, to guide the diagnosis of ARF. Methods: Over a one-year period, all spontaneously breathing adult patients consecutively admitted to the ICU for ARF were prospectively included. After training, 4 non-ultrasound experts performed LUS within 20 minutes of patient admission. They were blinded to patient medical history. LUS diagnosis was compared with the final clinical diagnosis made by the ICU team before patients were discharged from the ICU (gold standard). Results: Thirty-seven patients were included in the analysis (mean age, 73.2 ± 14.7 years; APACHE II, 19.2 ± 7.3). LUS diagnosis had a good agreement with the final diagnosis in 84% of patients (overall kappa, 0.81). The most common etiologies for ARF were pneumonia (n = 17) and hemodynamic lung edema (n = 15). The sensitivity and specificity of LUS as measured against the final diagnosis were, respectively, 88% and 90% for pneumonia and 86% and 87% for hemodynamic lung edema. Conclusions: LUS based on the BLUE protocol was reproducible by physicians who are not ultrasound experts and accurate for the diagnosis of pneumonia and hemodynamic lung edema. PMID:25750675

  3. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    PubMed

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Application of Metagenomic Sequencing to Food Safety: Detection of Shiga Toxin-Producing Escherichia coli on Fresh Bagged Spinach

    PubMed Central

    Leonard, Susan R.; Mammel, Mark K.; Lacher, David W.

    2015-01-01

    Culture-independent diagnostics reduce the reliance on traditional (and slower) culture-based methodologies. Here we capitalize on advances in next-generation sequencing (NGS) to apply this approach to food pathogen detection utilizing NGS as an analytical tool. In this study, spiking spinach with Shiga toxin-producing Escherichia coli (STEC) following an established FDA culture-based protocol was used in conjunction with shotgun metagenomic sequencing to determine the limits of detection, sensitivity, and specificity levels and to obtain information on the microbiology of the protocol. We show that an expected level of contamination (∼10 CFU/100 g) could be adequately detected (including key virulence determinants and strain-level specificity) within 8 h of enrichment at a sequencing depth of 10,000,000 reads. We also rationalize the relative benefit of static versus shaking culture conditions and the addition of selected antimicrobial agents, thereby validating the long-standing culture-based parameters behind such protocols. Moreover, the shotgun metagenomic approach was informative regarding the dynamics of microbial communities during the enrichment process, including initial surveys of the microbial loads associated with bagged spinach; the microbes found included key genera such as Pseudomonas, Pantoea, and Exiguobacterium. Collectively, our metagenomic study highlights and considers various parameters required for transitioning to such sequencing-based diagnostics for food safety and the potential to develop better enrichment processes in a high-throughput manner not previously possible. Future studies will investigate new species-specific DNA signature target regimens, rational design of medium components in concert with judicious use of additives, such as antibiotics, and alterations in the sample processing protocol to enhance detection. PMID:26386062

  5. Synchrotron x-ray microdiffraction reveals intrinsic structural features of amyloid deposits in situ.

    PubMed

    Briki, Fatma; Vérine, Jérôme; Doucet, Jean; Bénas, Philippe; Fayard, Barbara; Delpech, Marc; Grateau, Gilles; Riès-Kautt, Madeleine

    2011-07-20

    Amyloidoses are increasingly recognized as a major public health concern in Western countries. All amyloidoses share common morphological, structural, and tinctorial properties. These consist of staining by specific dyes, a fibrillar aspect in electron microscopy and a typical cross-β folding in x-ray diffraction patterns. Most studies that aim at deciphering the amyloid structure rely on fibers generated in vitro or extracted from tissues using protocols that may modify their intrinsic structure. Therefore, the fine details of the in situ architecture of the deposits remain unknown. Here, we present to our knowledge the first data obtained on ex vivo human renal tissue sections using x-ray microdiffraction. The typical cross-β features from fixed paraffin-embedded samples are similar to those formed in vitro or extracted from tissues. Moreover, the fiber orientation maps obtained across glomerular sections reveal an intrinsic texture that is correlated with the glomerulus morphology. These results are of the highest importance to understanding the formation of amyloid deposits and are thus expected to trigger new incentives for tissue investigation. Moreover, the access to intrinsic structural parameters such as fiber size and orientation using synchrotron x-ray microdiffraction, could provide valuable information concerning in situ mechanisms and deposit formation with potential benefits for diagnostic and therapeutic purposes. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  6. On-Orbit Prospective Echocardiography on International Space Station

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2010-01-01

    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

  7. Quantitative sensory testing of neuropathic pain patients: potential mechanistic and therapeutic implications.

    PubMed

    Pfau, Doreen B; Geber, Christian; Birklein, Frank; Treede, Rolf-Detlef

    2012-06-01

    Quantitative sensory testing (QST) is a widely accepted tool to investigate somatosensory changes in pain patients. Many different protocols have been developed in clinical pain research within recent years. In this review, we provide an overview of QST and tested neuroanatomical pathways, including peripheral and central structures. Based on research studies using animal and human surrogate models of neuropathic pain, possible underlying mechanisms of chronic pain are discussed. Clinically, QST may be useful for 1) the identification of subgroups of patients with different underlying pain mechanisms; 2) prediction of therapeutic outcomes; and 3) quantification of therapeutic interventions in pain therapy. Combined with sensory mapping, QST may provide useful information on the site of neural damage and on mechanisms of positive and negative somatosensory abnormalities. The use of QST in individual patients for diagnostic purposes leading to individualized therapy is an interesting concept, but needs further validation.

  8. An influenza A virus agglutination test using antibody-like polymers.

    PubMed

    Sukjee, Wannisa; Thitithanyanont, Arunee; Wiboon-Ut, Suwimon; Lieberzeit, Peter A; Paul Gleeson, M; Navakul, Krongkaew; Sangma, Chak

    2017-10-01

    Antibodies are commonly used in diagnostic routines to identify pathogens. The testing protocols are relatively simple, requiring a certain amount of a specific antibody to detect its corresponding pathogen. Antibody functionality can be mimicked by synthesizing molecularly imprinted polymers (MIPs), i.e. polymers that can selectively recognize a given template structure. Thus, MIPs are sometimes termed 'plastic antibody (PA)'. In this study, we have synthesized new granular MIPs using influenza A virus templates by precipitation polymerization. The selective binding of influenza A to the MIP particles was assessed and subsequently contrasted with other viruses. The affinities of influenza A virus towards the MIP was estimated based on an agglutination test by measuring the amount of influenza subtypes absorbed onto the MIPs. The MIPs produced using the H1N1 template showed specific reactivity to H1N1 while those produced using H5N1 and H3N2 templates showed cross-reactivity.

  9. Tailored hierarchical micelle architectures using living crystallization-driven self-assembly in two dimensions

    NASA Astrophysics Data System (ADS)

    Hudson, Zachary M.; Boott, Charlotte E.; Robinson, Matthew E.; Rupar, Paul A.; Winnik, Mitchell A.; Manners, Ian

    2014-10-01

    Recent advances in the self-assembly of block copolymers have enabled the precise fabrication of hierarchical nanostructures using low-cost solution-phase protocols. However, the preparation of well-defined and complex planar nanostructures in which the size is controlled in two dimensions (2D) has remained a challenge. Using a series of platelet-forming block copolymers, we have demonstrated through quantitative experiments that the living crystallization-driven self-assembly (CDSA) approach can be extended to growth in 2D. We used 2D CDSA to prepare uniform lenticular platelet micelles of controlled size and to construct precisely concentric lenticular micelles composed of spatially distinct functional regions, as well as complex structures analogous to nanoscale single- and double-headed arrows and spears. These methods represent a route to hierarchical nanostructures that can be tailored in 2D, with potential applications as diverse as liquid crystals, diagnostic technology and composite reinforcement.

  10. Electronic structure and optical properties of some anthocyanins extracted from grapes

    NASA Astrophysics Data System (ADS)

    Iosub, Ion; Kajzar, Francois; Makowska-Janusik, Malgorzata; Meghea, Aurelia; Tane, Alexandrina; Rau, Ileana

    2012-08-01

    The pallet of applications of natural dyes and pigments is continuously extending as a stringent need to meet the challenges arisen from sustainable development, particularly related to replacing synthetic chemicals by eco-friendly renewable raw materials. In this respect, the well known nutritive and therapeutic properties demonstrated by anthocyanin compounds present in selective plant extracts of numerous fruits, vegetables and flowers could be largely complemented by their characteristics as chromophores and fluorophores with high potential in promising applications in bio-imaging for diagnostic and therapy, but also in electronic and photonic devices, solar cells, etc. In this context, this paper proposes an improved protocol for extraction and HPLC detection of anthocyanins from black grapes. Moreover, in order to exploit their potential to be applied as chromatic and fluorescence molecular probes, the electronic properties have been studied by correlating spectral characteristics with trichromatic parameters, combined with quantum chemistry computation.

  11. Mandible condylar hyperplasia: a review of diagnosis and treatment protocol

    PubMed Central

    Olate, Sergio; Netto, Henrique Duque; Rodriguez-Chessa, Jaime; Alister, Juan Pablo; de Albergaria-Barbosa, Jose; de Moraes, Márcio

    2013-01-01

    Condylar hyperplasia (CH) is a bone disease characterized by the increased development of one mandibular condyle. It regularly presents as an active growth with facial asymmetry generally without pain. Statistically it affects more women in adolescence, although it does not discriminate by age or gender. Its best-known consequence is asymmetric facial deformity (AFD), which combined with alteration of the dental occlusion with unilateral crossbite or open bite. It is not known when CH begins and how long it lasts; diagnostic examinations are described and are efficient in some research about diagnosis. Protocol treatment is not well studie and depends on the criteria described in this paper. The aim of this research is to provide up-to-date information about the diagnosis of this disease and to analyze the treatment protocol, visualizing the CH and AFD presented. PMID:24179565

  12. Bacterial and fungal DNA extraction from blood samples: automated protocols.

    PubMed

    Lorenz, Michael G; Disqué, Claudia; Mühl, Helge

    2015-01-01

    Automation in DNA isolation is a necessity for routine practice employing molecular diagnosis of infectious agents. To this end, the development of automated systems for the molecular diagnosis of microorganisms directly in blood samples is at its beginning. Important characteristics of systems demanded for routine use include high recovery of microbial DNA, DNA-free containment for the reduction of DNA contamination from exogenous sources, DNA-free reagents and consumables, ideally a walkaway system, and economical pricing of the equipment and consumables. Such full automation of DNA extraction evaluated and in use for sepsis diagnostics is yet not available. Here, we present protocols for the semiautomated isolation of microbial DNA from blood culture and low- and high-volume blood samples. The protocols include a manual pretreatment step followed by automated extraction and purification of microbial DNA.

  13. Survey of protocols for the manual segmentation of the hippocampus: preparatory steps towards a joint EADC-ADNI harmonized protocol.

    PubMed

    Boccardi, Marina; Ganzola, Rossana; Bocchetta, Martina; Pievani, Michela; Redolfi, Alberto; Bartzokis, George; Camicioli, Richard; Csernansky, John G; de Leon, Mony J; deToledo-Morrell, Leyla; Killiany, Ronald J; Lehéricy, Stéphane; Pantel, Johannes; Pruessner, Jens C; Soininen, H; Watson, Craig; Duchesne, Simon; Jack, Clifford R; Frisoni, Giovanni B

    2011-01-01

    Manual segmentation from magnetic resonance imaging (MR) is the gold standard for evaluating hippocampal atrophy in Alzheimer's disease (AD). Nonetheless, different segmentation protocols provide up to 2.5-fold volume differences. Here we surveyed the most frequently used segmentation protocols in the AD literature as a preliminary step for international harmonization. The anatomical landmarks (anteriormost and posteriormost slices, superior, inferior, medial, and lateral borders) were identified from 12 published protocols for hippocampal manual segmentation ([Abbreviation] first author, publication year: [B] Bartzokis, 1998; [C] Convit, 1997; [dTM] deToledo-Morrell, 2004; [H] Haller, 1997; [J] Jack, 1994; [K] Killiany, 1993; [L] Lehericy, 1994; [M] Malykhin, 2007; [Pa] Pantel, 2000; [Pr] Pruessner, 2000; [S] Soininen, 1994; [W] Watson, 1992). The hippocampi of one healthy control and one AD patient taken from the 1.5T MR ADNI database were segmented by a single rater according to each protocol. The accuracy of the protocols' interpretation and translation into practice was checked with lead authors of protocols through individual interactive web conferences. Semantically harmonized landmarks and differences were then extracted, regarding: (a) the posteriormost slice, protocol [B] being the most restrictive, and [H, M, Pa, Pr, S] the most inclusive; (b) inclusion [C, dTM, J, L, M, Pr, W] or exclusion [B, H, K, Pa, S] of alveus/fimbria; (c) separation from the parahippocampal gyrus, [C] being the most restrictive, [B, dTM, H, J, Pa, S] the most inclusive. There were no substantial differences in the definition of the anteriormost slice. This survey will allow us to operationalize differences among protocols into tracing units, measure their impact on the repeatability and diagnostic accuracy of manual hippocampal segmentation, and finally develop a harmonized protocol.

  14. Real-time Ultrasound Assessment of Astronaut Spinal Anatomy and Disorders on the International Space Station.

    PubMed

    Garcia, Kathleen M; Harrison, Michael F; Sargsyan, Ashot E; Ebert, Douglas; Dulchavsky, Scott A

    2018-04-01

    Back pain is one of the most common conditions of astronauts during spaceflight and is hypothesized to be attributed to pathologic anatomic changes. Ultrasound (US) represents the only available imaging modality on the International Space Station, but a formal US protocol for imaging the structures of the spinal column does not exist. This investigation developed a method of acquiring diagnostic-quality images of the anterior lumbar and cervical regions of the spine during long-duration spaceflight. Comprehensive spinal US examinations were conducted on 7 long-duration spaceflight astronauts before flight, in flight, and after flight and compared to preflight and postflight magnetic resonance imaging data. In-flight scans were conducted after just-in-time training assisted by remote expert tele-US guidance. Novice users were able to obtain diagnostic-quality spinal images with a 92.5% success rate. Thirty-three anomalous or pathologic findings were identified during the preflight US analysis, and at least 14 new findings or progressions were identified during the postflight US analysis. Common findings included disk desiccation, osteophytes, and qualitative changes in the intervertebral disk height and angle. Ultrasound has proven efficacy as a portable and versatile diagnostic imaging modality under austere conditions. We demonstrated a potential role for US to evaluate spinal integrity and alterations in the extreme environment of space on the International Space Station. Further investigations should be performed to corroborate this imaging technique and to create a larger database related to in-flight spinal conditions during long-duration spaceflight. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Clinician, patient and general public beliefs about diagnostic imaging for low back pain: protocol for a qualitative evidence synthesis.

    PubMed

    Traeger, Adrian C; Reed, Benjamin J; O'Connor, Denise A; Hoffmann, Tammy C; Machado, Gustavo C; Bonner, Carissa; Maher, Chris G; Buchbinder, Rachelle

    2018-02-10

    Little is known about how to reduce unnecessary imaging for low back pain. Understanding clinician, patient and general public beliefs about imaging is critical to developing strategies to reduce overuse. To synthesise qualitative research that has explored clinician, patient or general public beliefs about diagnostic imaging for low back pain. We will perform a qualitative evidence synthesis of relevant qualitative research exploring clinician, patient and general public beliefs about diagnostic imaging for low back pain. Exclusions will be studies not using qualitative methods and studies not published in English. Studies will be identified using sensitive search strategies in MEDLINE, EMBASE, CINAHL, AMED and PsycINFO. Two reviewers will independently apply inclusion and exclusion criteria, extract data, and use the Critical Appraisal Skills Programme quality assessment tool to assess the quality of included studies. To synthesise the data we will use a narrative synthesis approach that involves developing a theoretical model, conducting a preliminary synthesis, exploring relations in the data, and providing a structured summary. We will code the data using NVivo. At least two reviewers will independently apply the thematic framework to extracted data. Confidence in synthesis findings will be evaluated using the GRADE Confidence in the Evidence from Reviews of Qualitative Research tool. Ethical approval is not required to conduct this review. We will publish the results in a peer-reviewed journal. CRD42017076047. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review

    PubMed Central

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Engel, Mark E

    2018-01-01

    Introduction Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Methods and analysis Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics and dissemination Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this review warrant a change in clinical practice, a summary report will be disseminated among leading clinicians and healthcare professionals in the field. PROSPERO registration number CRD42016051261. PMID:29440164

  17. Nationwide trends in use and timeliness of diagnostic coronary angiography in acute coronary syndromes from 2005 to 2011: Does distance to invasive heart centres matter?

    PubMed

    Hansen, Kim W; Sørensen, Rikke; Madsen, Mette; Madsen, Jan K; Jensen, Jan S; von Kappelgaard, Lene M; Mortensen, Poul E; Galatius, Søren

    2015-08-01

    To examine trends in the use of diagnostic coronary angiography according to distance from home to the nearest invasive heart centre following implementation of fast-track protocols and extensive pre-hospital triaging of acute coronary syndrome patients. We performed a register-based cohort study of all patients admitted to Danish hospitals with incident acute coronary syndrome in 2005-2011. Diagnostic coronary angiography within 60 days of admission was investigated according to distance tertiles (DTs) calculated as range from each patient's home to the nearest invasive heart centre (short DT: <22 km, medium DT: 22-65 km, long DT: >65 km). Cox proportional hazards models were applied.Among the 52,409 patients included, diagnostic coronary angiography was increasingly used during 2005-2011 (short DT: 76% to 81%; medium DT: 74% to 81%; long DT: 69% to 78%; all p-values for trend <0.001). Using the short DT as reference the adjusted hazard ratios for medium DT were 0.87 (0.84-0.89) for 2005-2007, 0.94 (0.90-0.98) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Corresponding figures for long DT were 0.74 (0.72-0.76) for 2005-2007, 0.87 (0.83-0.90) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Length of hospital stay, time to coronary angiography, and 60-day mortality decreased in all DT. This nationwide study found significant increases in diagnostic coronary angiography use over time in incident acute coronary syndrome patients with a relatively larger increase in patients residing farthest from an invasive heart centre. Additionally, selected quality of care measures improved in the entire cohort, suggesting a benefit of national clinical protocols. © The European Society of Cardiology 2014.

  18. Accuracy of LightCycler(R) SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol.

    PubMed

    Dark, Paul; Wilson, Claire; Blackwood, Bronagh; McAuley, Danny F; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Warhurst, Geoffrey

    2012-01-01

    Background There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. Registration PROSPERO-NIHR Prospective Register of Systematic Reviews (CRD42011001289).

  19. Diagnostic Accuracy of Chinese Medicine Diagnosis Scale of Phlegm and Blood Stasis Syndrome in Coronary Heart Disease: A Study Protocol.

    PubMed

    Liu, Xiao-Qi; Peng, Dan-Hong; Wang, Yan-Ping; Xie, Rong; Chen, Xin-Lin; Yu, Chun-Quan; Li, Xian-Tao

    2018-05-03

    Phlegm and blood stasis syndrome (PBSS) is one of the main syndromes in coronary heart disease (CHD). Syndromes of Chinese medicine (CM) are lack of quantitative and easyimplementation diagnosis standards. To quantify and standardize the diagnosis of PBSS, scales are usually applied. To evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. Six hundred patients with stable angina pectoris of CHD, 300 in case group and 300 in control group, will be recruited from 5 hospitals across China. Diagnosis from 2 experts will be considered as the "gold standard". The study design consists of 2 phases: pilot test is used to evaluate the reliability and validity, and diagnostic test is used to assess the diagnostic accuracy of the scale, including sensitivity, specififi city, likelihood ratio and area under the receiver operator characteristic (ROC) curve. This study will evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. The consensus of 2 experts may not be ideal as a "gold standard", and itself still requires further study. (No. ChiCTR-OOC-15006599).

  20. Therapeutic Treatment Protocol for Enuresis Using an Enuresis Alarm

    ERIC Educational Resources Information Center

    Shapira, Bettina E.; Dahlen, Penny

    2010-01-01

    Enuresis, one of the most prevalent and chronic childhood disorders, imposes serious financial, physical, and emotional burdens on the child and the family affected by it. This article provides counselors with an overview of the complex etiologies, diagnostic criteria, and current treatment options for the disorder, as well as assessment tools and…

  1. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  2. 21 CFR 660.46 - Samples; protocols; official release.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... with 125I or unlyophilized HBsAg-coated red blood cells means a sample from each lot of diagnostic test...) One sample until written notification of official release is no longer required under paragraph (c)(2... notification of official release is no longer required under paragraph (c)(2) of this section. The sample...

  3. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  4. 21 CFR 660.46 - Samples; protocols; official release.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... with 125I or unlyophilized HBsAg-coated red blood cells means a sample from each lot of diagnostic test...) One sample until written notification of official release is no longer required under paragraph (c)(2... notification of official release is no longer required under paragraph (c)(2) of this section. The sample...

  5. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  6. 21 CFR 660.46 - Samples; protocols; official release.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... with 125I or unlyophilized HBsAg-coated red blood cells means a sample from each lot of diagnostic test...) One sample until written notification of official release is no longer required under paragraph (c)(2... notification of official release is no longer required under paragraph (c)(2) of this section. The sample...

  7. Evaluation of Core Vocabulary Intervention for Treatment of Inconsistent Phonological Disorder: Three Treatment Case Studies

    ERIC Educational Resources Information Center

    McIntosh, Beth; Dodd, Barbara

    2009-01-01

    Children with unintelligible speech differ in severity, underlying deficit, type of surface error patterns and response to treatment. Detailed treatment case studies, evaluating specific intervention protocols for particular diagnostic groups, can identify best practice for children with speech disorder. Three treatment case studies evaluated the…

  8. Evidence-Based Assessment in Case Management to Improve Abnormal Cancer Screen Follow-Up

    ERIC Educational Resources Information Center

    Vourlekis, Betsy; Ell, Kathleen; Padgett, Deborah

    2005-01-01

    The authors describe an evidence-based assessment protocol for intensive case management to improve screening diagnostic follow-up developed through a research project in breast and cervical cancer early detection funded by the Centers for Disease Control and Prevention. Three components of an evidence-based approach to assessment are presented…

  9. Introduction of an accelerated diagnostic protocol in the assessment of emergency department patients with possible acute coronary syndrome: the Nambour Short Low-Intermediate Chest pain project.

    PubMed

    George, Terry; Ashover, Sarah; Cullen, Louise; Larsen, Peter; Gibson, Jason; Bilesky, Jennifer; Coverdale, Steven; Parsonage, William

    2013-08-01

    Emergency physicians can feel pressured by opposing forces of clinical reality and the need to publish successful key performance indicators in an environment of increasing demands and cost containment. This is particularly relevant to management of patients with undifferentiated chest pain and possible acute coronary syndrome. Unreliability of clinical assessment and high risk of adverse outcomes for all concerned exist, yet national guidelines are at odds with efforts to reduce ED crowding and access block. We report findings from the Nambour Short Low-Intermediate Chest pain risk trial, which safely introduced an accelerated diagnostic protocol with reduced ED length of stay and high patient acceptability. Over a 7-month period, there were no major adverse cardiac events by 30 days in 19% of undifferentiated chest pain presentations with possible acute coronary syndrome discharged after normal sensitive cardiac troponin taken 2 h after presentation and scheduled to return for outpatient exercise stress test. © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  10. International veterinary epilepsy task force recommendations for systematic sampling and processing of brains from epileptic dogs and cats.

    PubMed

    Matiasek, Kaspar; Pumarola I Batlle, Martí; Rosati, Marco; Fernández-Flores, Francisco; Fischer, Andrea; Wagner, Eva; Berendt, Mette; Bhatti, Sofie F M; De Risio, Luisa; Farquhar, Robyn G; Long, Sam; Muñana, Karen; Patterson, Edward E; Pakozdy, Akos; Penderis, Jacques; Platt, Simon; Podell, Michael; Potschka, Heidrun; Rusbridge, Clare; Stein, Veronika M; Tipold, Andrea; Volk, Holger A

    2015-08-28

    Traditionally, histological investigations of the epileptic brain are required to identify epileptogenic brain lesions, to evaluate the impact of seizure activity, to search for mechanisms of drug-resistance and to look for comorbidities. For many instances, however, neuropathological studies fail to add substantial data on patients with complete clinical work-up. This may be due to sparse training in epilepsy pathology and or due to lack of neuropathological guidelines for companion animals.The protocols introduced herein shall facilitate systematic sampling and processing of epileptic brains and therefore increase the efficacy, reliability and reproducibility of morphological studies in animals suffering from seizures.Brain dissection protocols of two neuropathological centres with research focus in epilepsy have been optimised with regards to their diagnostic yield and accuracy, their practicability and their feasibility concerning clinical research requirements.The recommended guidelines allow for easy, standardised and ubiquitous collection of brain regions, relevant for seizure generation. Tissues harvested the prescribed way will increase the diagnostic efficacy and provide reliable material for scientific investigations.

  11. [CHRONIC PERIODONTITIS WITH SYMPTOMATIC HYPERTROPHIC GINGIVITIS: CASE REPORT AND REVIEW OF THE LITERATURE].

    PubMed

    Shinkevich, V; Udaltsova, K; Pisarenko, E; Kolomiets, S; Khmil, T

    2015-12-01

    Gingivitis in traditional national dentistry referred to independent diseases or symptomatic condition in periodontitis and classified morphologically. The diagnostic features of the diseases are characteristic, but the clinical presentation of symptomatic gingivitis and patterns of bone destructions may vary between patients. Successful treatment of the disease depends from proper diagnosis and advanced disease stages, but for symptomatic gingivitis that accompanying chronic periodontitis, protocols include surgical excision. Despite of the high prevalence of chronic generalized periodontitis, its active treatment often start in severe destruction and bone loss (2-3 stage severity). Today etiotropic antimicrobial therapy is real way to control microbial biofilm and has solid evidence base. Applying of etiotropic antimicrobial therapy as systemic azithromycin with timely treatment of mild to moderate periodontal and bone destruction may reduce severe periodontitis incidence of and treatment-related complications in the future. This paper attempts to describe the clinical diagnostic features and the current treatment options along with a suggested protocol for comprehensive management of chronic generalized periodontitis and hypertrophic gingivitis patient with case reports and a brief review.

  12. Structure induction in diagnostic causal reasoning.

    PubMed

    Meder, Björn; Mayrhofer, Ralf; Waldmann, Michael R

    2014-07-01

    Our research examines the normative and descriptive adequacy of alternative computational models of diagnostic reasoning from single effects to single causes. Many theories of diagnostic reasoning are based on the normative assumption that inferences from an effect to its cause should reflect solely the empirically observed conditional probability of cause given effect. We argue against this assumption, as it neglects alternative causal structures that may have generated the sample data. Our structure induction model of diagnostic reasoning takes into account the uncertainty regarding the underlying causal structure. A key prediction of the model is that diagnostic judgments should not only reflect the empirical probability of cause given effect but should also depend on the reasoner's beliefs about the existence and strength of the link between cause and effect. We confirmed this prediction in 2 studies and showed that our theory better accounts for human judgments than alternative theories of diagnostic reasoning. Overall, our findings support the view that in diagnostic reasoning people go "beyond the information given" and use the available data to make inferences on the (unobserved) causal rather than on the (observed) data level. (c) 2014 APA, all rights reserved.

  13. A risk factor screening and assessment protocol for schizophrenia and related psychosis.

    PubMed

    Carr, V; Halpin, S; Lau, N; O'Brien, S; Beckmann, J; Lewin, T

    2000-11-01

    The Psychological Assistance Service (PAS) opened in Newcastle, New South Wales in 1997 as a clinical service for the assessment and treatment of young people at high risk of psychosis and those experiencing a first psychotic episode. The aim of this paper is to describe the assessment protocol of PAS, which is strongly influenced by the neurodevelopmental perspective on early onset psychosis. The systematic assessment of patients referred to PAS using a protocol over a 2 week period is described. The protocol includes a narrative history, structured diagnostic interview, quantitative assessment of symptoms and other clinical features, a neurological examination and comprehensive neuropsychological test battery. The clinic has received over 250 referrals in a 2 year period and accepted 116 patients for a full assessment, of whom 60 were deemed to be 'at-risk' of psychosis and 56 were experiencing their first psychotic episode. Both groups were similar with respect to gender and there were minor age differences. The first-episode group experienced more reality distortion, schizotypal and negative symptoms. While both groups showed some neuropsychological and neurological impairment, there were no statistically significant differences between the groups on these variables except for a test of executive functioning in which the first-episode group was more impaired than the 'at-risk' group. A low rate of conversion to psychosis occurred in the 'at-risk' group. The minor differences between the two groups may have been related to relatively small sample sizes, although some similarities between the groups were to be expected. The low rate of conversion to psychosis in the 'at-risk' group is discussed. Further analyses using larger samples are necessary to determine the validity of the various 'at-risk' categories and this will involve following a sufficiently large sample over an adequate time. The most efficient way of doing this would be to pool data across centres with comparable early intervention programs.

  14. SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tonkopi, E; Abdolell, M; Duffy, S

    2015-06-15

    Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentilemore » of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.« less

  15. A cluster randomised controlled trial of a brief couple-focused psychoeducational intervention to prevent common postnatal mental disorders among women: study protocol.

    PubMed

    Rowe, Heather; Wynter, Karen; Lorgelly, Paula; Amir, Lisa H; Ranasinha, Sanjeeva; Proimos, Jenny; Cann, Warren; Hiscock, Harriet; Bayer, Jordana; Burns, Joanna; Ride, Jemimah; Bobevski, Irene; Fisher, Jane

    2014-09-23

    Postnatal common mental disorders among women are an important public health problem internationally. Interventions to prevent postnatal depression have had limited success. What Were We Thinking (WWWT) is a structured, gender-informed, psychoeducational group programme for parents and their first infant that addresses two modifiable risks to postnatal mental health. This paper describes the protocol for a cluster randomised controlled trial to test the clinical effectiveness and cost-effectiveness of WWWT when implemented in usual primary care. 48 maternal and child health (MCH) centres from six diverse Local Government Areas, in Victoria, Australia are randomly allocated to the intervention group (usual care plus WWWT) or the control group (usual care). The required sample size is 184 women in each group. English-speaking primiparous women receiving postpartum healthcare in participating MCH centres complete two computer-assisted telephone interviews: baseline at 4 weeks and outcome at 6 months postpartum. Women attending intervention MCH centres are invited to attend WWWT in addition to usual care. The primary outcome is meeting Diagnostic and Statistical Manual-IV (DSM-IV) diagnostic criteria for major depressive episode; generalised anxiety disorder; panic disorder with or without agoraphobia, agoraphobia with or without panic, social phobia, adult separation anxiety or adjustment disorder with depressed mood, anxiety or mixed depressed mood and anxiety within the past 30 days at 6 months postpartum. Secondary outcomes are self-rated general and emotional health, infant sleep problems, method of infant feeding, quality of mother-infant relationship and intimate partner relationship, and healthcare costs and outcomes. Approval to conduct the study has been granted. A comprehensive dissemination plan has been devised. Australian New Zealand Clinical Trials Registry ACTRN12613000506796. UTN: U1111-1125-8208. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia.

    PubMed

    Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T; Zhang, Tao; Lustig, Michael; Vasanawala, Shreyas S

    2017-05-01

    To assess the feasibility of ferumoxytol-enhanced anesthesia-free cardiac MRI in neonates and young infants for complex congenital heart disease (CHD). With Institutional Review Board approval, 21 consecutive neonates and young infants (1 day to 11 weeks old; median age of 3 days) who underwent a rapid two-sequence (MR angiography [MRA] and four-dimensional [4D] flow) MRI protocol with intravenous ferumoxytol without sedation (n = 17) or light sedation (n = 4) at 3 Tesla (T) (except one case at 1.5T) between June 2014 and February 2016 were retrospectively identified. Medical records were reviewed for indication, any complications, if further diagnostic imaging was performed after MRI, and surgical findings. Two radiologists scored the images in two sessions on a 5-point scale for overall image quality and delineation of various anatomical structures. Confidence interval of proportions for likelihood of requiring additional diagnostic imaging after MRI was determined. For the possibility of reducing the protocol to a single rapid sequence, Wilcoxon-rank sum test was used to assess whether 4D flow and MRA significantly differed in anatomical delineation. One of 21 patients (4.8%, 80% confidence interval 0-11%) required additional imaging, a computed tomography angiography to assess lung parenchyma and peripheral pulmonary arteries. Only 1 of 13 patients (7.7%) with operative confirmation had a minor discrepancy between radiology and operative reports (80% confidence interval 0-17%). 4D flow was significantly superior to MRA (P < 0.05) for the evaluation of systemic arteries, valves, ventricular trabeculae, and overall quality. Using Cohen's kappa coefficient, there was good interobserver agreement for the evaluation of systemic arteries by 4D flow (κ = 0.782), and systemic veins and pulmonary arteries by MRA (κ > 0.6). Overall 4D flow measurements (mean κ = 0.64-0.74) had better internal agreement compared with MRA (mean κ = 0.30-0.64). Ferumoxytol-enhanced cardiac MRI, without anesthesia, is feasible for the evaluation of complex CHD in neonates and young infants, with a low likelihood of need for additional diagnostic studies. The decreased risk by avoiding anesthesia must be balanced against the potential for adverse reactions with ferumoxytol. 2 J. MAGN. RESON. IMAGING 2017;45:1407-1418. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Characterization of Incidental Renal Mass With Dual-Energy CT: Diagnostic Accuracy of Effective Atomic Number Maps for Discriminating Nonenhancing Cysts From Enhancing Masses.

    PubMed

    Mileto, Achille; Allen, Brian C; Pietryga, Jason A; Farjat, Alfredo E; Zarzour, Jessica G; Bellini, Davide; Ebner, Lukas; Morgan, Desiree E

    2017-10-01

    The purpose of this study was to assess the diagnostic accuracy of effective atomic number maps reconstructed from dual-energy contrast-enhanced data for discriminating between nonenhancing renal cysts and enhancing masses. Two hundred six patients (128 men, 78 women; mean age, 64 years) underwent a CT renal mass protocol (single-energy unenhanced and dual-energy contrast-enhanced nephrographic imaging) at two different hospitals. For each set of patients, two blinded, independent observers performed measurements on effective atomic number maps from contrast-enhanced dual-energy data. Renal mass assessment on unenhanced and nephrographic images, corroborated by imaging and medical records, was the reference standard. The diagnostic accuracy of effective atomic number maps was assessed with ROC analysis. Significant differences in mean effective atomic numbers (Z eff ) were observed between nonenhancing and enhancing masses (set A, 8.19 vs 9.59 Z eff ; set B, 8.05 vs 9.19 Z eff ; sets combined, 8.13 vs 9.37 Z eff ) (p < 0.0001). An effective atomic number value of 8.36 Z eff was the optimal threshold, rendering an AUC of 0.92 (95% CI, 0.89-0.94), sensitivity of 90.8% (158/174 [95% CI, 85.5-94.7%]), specificity of 85.2% (445/522 [95% CI, 81.9-88.2%]), and overall diagnostic accuracy of 86.6% (603/696 [95% CI, 83.9-89.1%]). Nonenhancing renal cysts, including hyperattenuating cysts, can be discriminated from enhancing masses on effective atomic number maps generated from dual-energy contrast-enhanced CT data. This technique may be of clinical usefulness when a CT protocol for comprehensive assessment of renal masses is not available.

  18. The diagnosis of primary eosinophilic oesophagitis in adults: missed or misinterpreted?

    PubMed

    Kanakala, Venkatesh; Lamb, Christopher A; Haigh, Chris; Stirling, Robert W; Attwood, Stephen E

    2010-07-01

    The diagnosis of adult eosinophilic oesophagitis (EOE) is rarely made in the UK despite projections of high frequency and prevalence within Western society. This study aimed to identify the frequency of diagnosis of EOE in our community, and to establish reasons for diagnostic failure or delay. The pathology records of all gastroscopies performed (67 840) in Northumbria NHS trust during the years January 2001-November 2008 were reviewed for oesophageal eosinophilia. Case notes and investigations were then inspected to identify patients with a diagnosis of EOE in accordance with American Gastroenterology Association guidelines. In total, 37 patients fulfilled diagnostic criteria for EOE. The mean duration of symptoms before the diagnosis was 4 years (range 4 months-30 years) and 14 patients (38%) remained undiagnosed until the time of study. Reasons for diagnostic failure and delay included: delayed request for endoscopy in patients with dysphagia (49%, n=18 of 37); poor recognition of typical endoscopic appearances of EOE (16%, n=6 of 37); clinical mislabelling as gastro-oesophageal reflux disease (22%, n=8 of 37) and candida (13%, n=5 of 37); histological mislabelling as gastro-oesophageal reflux disease (19%, n=7 of 37), candida (5%, n=2 of 37), 'inflammation' (8%, n=3 of 37) and Barrett's oesophagus (3%, n=1 of 37); failed recognition or recording of maximal eosinophil concentrations within biopsies (35%, n=13 of 37). In 40% (n=15 of 37) of patients the decision to biopsy was based solely on a dysphagia protocol introduced in 2004. No cases were identified before the protocol implementation. EOE is underdiagnosed in our community owing to lack of clinical suspicion, failure to biopsy, and histopathological misinterpretation. Educating clinicians and pathologists before planning an endoscopy may improve the diagnostic sensitivity.

  19. Improved cryoEM-Guided Iterative Molecular Dynamics–Rosetta Protein Structure Refinement Protocol for High Precision Protein Structure Prediction

    PubMed Central

    2016-01-01

    Many excellent methods exist that incorporate cryo-electron microscopy (cryoEM) data to constrain computational protein structure prediction and refinement. Previously, it was shown that iteration of two such orthogonal sampling and scoring methods – Rosetta and molecular dynamics (MD) simulations – facilitated exploration of conformational space in principle. Here, we go beyond a proof-of-concept study and address significant remaining limitations of the iterative MD–Rosetta protein structure refinement protocol. Specifically, all parts of the iterative refinement protocol are now guided by medium-resolution cryoEM density maps, and previous knowledge about the native structure of the protein is no longer necessary. Models are identified solely based on score or simulation time. All four benchmark proteins showed substantial improvement through three rounds of the iterative refinement protocol. The best-scoring final models of two proteins had sub-Ångstrom RMSD to the native structure over residues in secondary structure elements. Molecular dynamics was most efficient in refining secondary structure elements and was thus highly complementary to the Rosetta refinement which is most powerful in refining side chains and loop regions. PMID:25883538

  20. Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease

    PubMed Central

    2013-01-01

    Cardiovascular magnetic resonance (CMR) has taken on an increasingly important role in the diagnostic evaluation and pre-procedural planning for patients with congenital heart disease. This article provides guidelines for the performance of CMR in children and adults with congenital heart disease. The first portion addresses preparation for the examination and safety issues, the second describes the primary techniques used in an examination, and the third provides disease-specific protocols. Variations in practice are highlighted and expert consensus recommendations are provided. Indications and appropriate use criteria for CMR examination are not specifically addressed. PMID:23763839

  1. Colon cleansing protocol in children: research conditions vs. clinical practice.

    PubMed

    Elitsur, Yoram; Balfaqih, Yaslam; Preston, Deborah

    2018-04-01

     Colon preparation rates are the limiting factor for a successful diagnostic colonoscopy in children. Different colon cleansing protocols have been published for use in children. Unfortunately, the applicability of those published research protocols has not been formally evaluated in routine clinical practice. We investigated the success rate of our previously published colon cleansing protocol as utilized in our clinical practice.  This was a retrospective study. In the clinical practice, the colon cleansing protocol included PEG-3350 at a dose of 2 g/kg/day plus Dulcolax (Bisacodyl, Boehringer Ingelheim, TX USA) 5 mg/day for 2 days. Adequate colon preparation was graded between 1 - 5, as previously described, and grade ≥ 4.0 was considered an adequate preparation. Patients were instructed to complete a questionnaire that included PEG-3350 dose, number of stools per day, consistency of each stool, and side effects (vomiting, abdominal pain). Clinical and endoscopic results were compared between the protocol under research conditions and routine practice.  The success rate of the colon preparation in our clinical practice was similar to the results observed under our research protocol (75 % vs. 73.6 %). Moreover, the total number of stools, stool consistency, and the intubation rate of the terminal ileum were also similar. We concluded, that in our experience, the colon cleansing protocol used under research conditions was effective and appropriate for use in routine clinical practice.  We recommend testing each new protocol under the routine conditions of clinical practice to confirm its applicability for general practitioners.

  2. Introducing automation to the molecular diagnosis of Trypanosoma cruzi infection: A comparative study of sample treatments, DNA extraction methods and real-time PCR assays.

    PubMed

    Abras, Alba; Ballart, Cristina; Llovet, Teresa; Roig, Carme; Gutiérrez, Cristina; Tebar, Silvia; Berenguer, Pere; Pinazo, María-Jesús; Posada, Elizabeth; Gascón, Joaquim; Schijman, Alejandro G; Gállego, Montserrat; Muñoz, Carmen

    2018-01-01

    Polymerase chain reaction (PCR) has become a useful tool for the diagnosis of Trypanosoma cruzi infection. The development of automated DNA extraction methodologies and PCR systems is an important step toward the standardization of protocols in routine diagnosis. To date, there are only two commercially available Real-Time PCR assays for the routine laboratory detection of T. cruzi DNA in clinical samples: TCRUZIDNA.CE (Diagnostic Bioprobes Srl) and RealCycler CHAG (Progenie Molecular). Our aim was to evaluate the RealCycler CHAG assay taking into account the whole process. We assessed the usefulness of an automated DNA extraction system based on magnetic particles (EZ1 Virus Mini Kit v2.0, Qiagen) combined with a commercially available Real-Time PCR assay targeting satellite DNA (SatDNA) of T. cruzi (RealCycler CHAG), a methodology used for routine diagnosis in our hospital. It was compared with a well-known strategy combining a commercial DNA isolation kit based on silica columns (High Pure PCR Template Preparation Kit, Roche Diagnostics) with an in-house Real-Time PCR targeting SatDNA. The results of the two methodologies were in almost perfect agreement, indicating they can be used interchangeably. However, when variations in protocol factors were applied (sample treatment, extraction method and Real-Time PCR), the results were less convincing. A comprehensive fine-tuning of the whole procedure is the key to successful results. Guanidine EDTA-blood (GEB) samples are not suitable for DNA extraction based on magnetic particles due to inhibition, at least when samples are not processed immediately. This is the first study to evaluate the RealCycler CHAG assay taking into account the overall process, including three variables (sample treatment, extraction method and Real-Time PCR). Our findings may contribute to the harmonization of protocols between laboratories and to a wider application of Real-Time PCR in molecular diagnostic laboratories associated with health centers.

  3. Ultra-low-dose computed tomographic angiography with model-based iterative reconstruction compared with standard-dose imaging after endovascular aneurysm repair: a prospective pilot study.

    PubMed

    Naidu, Sailen G; Kriegshauser, J Scott; Paden, Robert G; He, Miao; Wu, Qing; Hara, Amy K

    2014-12-01

    An ultra-low-dose radiation protocol reconstructed with model-based iterative reconstruction was compared with our standard-dose protocol. This prospective study evaluated 20 men undergoing surveillance-enhanced computed tomography after endovascular aneurysm repair. All patients underwent standard-dose and ultra-low-dose venous phase imaging; images were compared after reconstruction with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction. Objective measures of aortic contrast attenuation and image noise were averaged. Images were subjectively assessed (1 = worst, 5 = best) for diagnostic confidence, image noise, and vessel sharpness. Aneurysm sac diameter and endoleak detection were compared. Quantitative image noise was 26% less with ultra-low-dose model-based iterative reconstruction than with standard-dose adaptive statistical iterative reconstruction and 58% less than with ultra-low-dose adaptive statistical iterative reconstruction. Average subjective noise scores were not different between ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction (3.8 vs. 4.0, P = .25). Subjective scores for diagnostic confidence were better with standard-dose adaptive statistical iterative reconstruction than with ultra-low-dose model-based iterative reconstruction (4.4 vs. 4.0, P = .002). Vessel sharpness was decreased with ultra-low-dose model-based iterative reconstruction compared with standard-dose adaptive statistical iterative reconstruction (3.3 vs. 4.1, P < .0001). Ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction aneurysm sac diameters were not significantly different (4.9 vs. 4.9 cm); concordance for the presence of endoleak was 100% (P < .001). Compared with a standard-dose technique, an ultra-low-dose model-based iterative reconstruction protocol provides comparable image quality and diagnostic assessment at a 73% lower radiation dose.

  4. Diagnostics for Lassa Fever: Detecting Host Antibody Responses.

    PubMed

    Salvato, Maria S; Lukashevich, Igor S; Medina-Moreno, Sandra; Zapata, Juan Carlos

    2018-01-01

    There are two types of viral diagnostics: (1) those that detect components of the pathogen (like viral RNA or proteins) and (2) those that detect host molecules that rise or fall as a consequence of pathogen infection (like anti-viral antibodies or virus-induced inflammatory cytokines). Quantitative PCR to detect Lassa RNA, and clinical chemistry to detect high liver enzymes (AST/ALT) are commonly used to diagnose Lassa fever. Here, we discuss the various types of diagnostics for Lassa fever and the urgent need for early diagnosis. We also describe a protocol for using the attenuated Lassa vaccine candidate, ML29 , as an antigen for detecting Lassa-specific antibodies. Since antibodies are developed late in the progression of Lassa fever disease, this is not an early diagnostic, but is more useful in surveillance of the population to determine the sero-prevalence of antibodies to Lassa virus (LASV ), and to define treatment options for people in close contact with a Lassa-infected person.

  5. Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps.

    PubMed

    Wong, Jessica X H; Li, Xiaochun; Liu, Frank S F; Yu, Hua-Zhong

    2015-06-30

    The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today's smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps.

  6. Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps

    PubMed Central

    Wong, Jessica X. H.; Li, Xiaochun; Liu, Frank S. F.; Yu, Hua-Zhong

    2015-01-01

    The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today’s smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps. PMID:26122608

  7. Bulgarian experience in the establishment of reference dose levels and implementation of a quality control system in diagnostic radiology.

    PubMed

    Vassileva, J; Dimov, A; Slavchev, A; Karadjov, A

    2005-01-01

    Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.

  8. Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps

    NASA Astrophysics Data System (ADS)

    Wong, Jessica X. H.; Li, Xiaochun; Liu, Frank S. F.; Yu, Hua-Zhong

    2015-06-01

    The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today’s smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps.

  9. Using comparative genomics to develop a molecular diagnostic for the identification of an emerging pest Drosophila suzukii.

    PubMed

    Murphy, K A; Unruh, T R; Zhou, L M; Zalom, F G; Shearer, P W; Beers, E H; Walton, V M; Miller, B; Chiu, J C

    2015-06-01

    Drosophila suzukii (Spotted Wing Drosophila) has recently become a serious invasive pest of fruit crops in the USA, Canada, and Europe, leading to substantial economic losses. D. suzukii is a direct pest, ovipositing directly into ripe or ripening fruits; in contrast, other Drosophilids utilize decaying or blemished fruits and are nuisance pests at worst. Immature stages of D. suzukii are difficult to differentiate from other Drosophilids, posing problems for research and for meeting quarantine restrictions designed to prevent the spread of this pest in fruit exports. Here we used a combined phylogenetic and bioinformatic approach to discover genetic markers suitable for a species diagnostic protocol of this agricultural pest. We describe a molecular diagnostic for rapid identification of single D. suzukii larva using multiplex polymerase chain reaction. Our molecular diagnostic was validated using nine different species of Drosophila for specificity and 19 populations of D. suzukii from different geographical regions to ensure utility within species.

  10. Improved prediction of antibody VL–VH orientation

    PubMed Central

    Marze, Nicholas A.; Lyskov, Sergey; Gray, Jeffrey J.

    2016-01-01

    Antibodies are important immune molecules with high commercial value and therapeutic interest because of their ability to bind diverse antigens. Computational prediction of antibody structure can quickly reveal valuable information about the nature of these antigen-binding interactions, but only if the models are of sufficient quality. To achieve high model quality during complementarity-determining region (CDR) structural prediction, one must account for the VL–VH orientation. We developed a novel four-metric VL–VH orientation coordinate frame. Additionally, we extended the CDR grafting protocol in RosettaAntibody with a new method that diversifies VL–VH orientation by using 10 VL–VH orientation templates rather than a single one. We tested the multiple-template grafting protocol on two datasets of known antibody crystal structures. During the template-grafting phase, the new protocol improved the fraction of accurate VL–VH orientation predictions from only 26% (12/46) to 72% (33/46) of targets. After the full RosettaAntibody protocol, including CDR H3 remodeling and VL–VH re-orientation, the new protocol produced more candidate structures with accurate VL–VH orientation than the standard protocol in 43/46 targets (93%). The improved ability to predict VL–VH orientation will bolster predictions of other parts of the paratope, including the conformation of CDR H3, a grand challenge of antibody homology modeling. PMID:27276984

  11. FoldGPCR: structure prediction protocol for the transmembrane domain of G protein-coupled receptors from class A.

    PubMed

    Michino, Mayako; Chen, Jianhan; Stevens, Raymond C; Brooks, Charles L

    2010-08-01

    Building reliable structural models of G protein-coupled receptors (GPCRs) is a difficult task because of the paucity of suitable templates, low sequence identity, and the wide variety of ligand specificities within the superfamily. Template-based modeling is known to be the most successful method for protein structure prediction. However, refinement of homology models within 1-3 A C alpha RMSD of the native structure remains a major challenge. Here, we address this problem by developing a novel protocol (foldGPCR) for modeling the transmembrane (TM) region of GPCRs in complex with a ligand, aimed to accurately model the structural divergence between the template and target in the TM helices. The protocol is based on predicted conserved inter-residue contacts between the template and target, and exploits an all-atom implicit membrane force field. The placement of the ligand in the binding pocket is guided by biochemical data. The foldGPCR protocol is implemented by a stepwise hierarchical approach, in which the TM helical bundle and the ligand are assembled by simulated annealing trials in the first step, and the receptor-ligand complex is refined with replica exchange sampling in the second step. The protocol is applied to model the human beta(2)-adrenergic receptor (beta(2)AR) bound to carazolol, using contacts derived from the template structure of bovine rhodopsin. Comparison with the X-ray crystal structure of the beta(2)AR shows that our protocol is particularly successful in accurately capturing helix backbone irregularities and helix-helix packing interactions that distinguish rhodopsin from beta(2)AR. (c) 2010 Wiley-Liss, Inc.

  12. Survey of Protocols for the Manual Segmentation of the Hippocampus: Preparatory Steps Towards a Joint EADC-ADNI Harmonized Protocol

    PubMed Central

    Boccardi, Marina; Ganzola, Rossana; Bocchetta, Martina; Pievani, Michela; Redolfi, Alberto; Bartzokis, George; Camicioli, Richard; Csernansky, John G.; de Leon, Mony J.; deToledo-Morrell, Leyla; Killiany, Ronald J.; Lehéricy, Stéphane; Pantel, Johannes; Pruessner, Jens C.; Soininen, H.; Watson, Craig; Duchesne, Simon; Jack, Clifford R.; Frisoni, Giovanni B.

    2013-01-01

    Manual segmentation from magnetic resonance imaging (MR) is the gold standard for evaluating hippocampal atrophy in Alzheimer’s disease (AD). Nonetheless, different segmentation protocols provide up to 2.5-fold volume differences. Here we surveyed the most frequently used segmentation protocols in the AD literature as a preliminary step for international harmonization. The anatomical landmarks (anteriormost and posteriormost slices, superior, inferior, medial, and lateral borders) were identified from 12 published protocols for hippocampal manual segmentation ([Abbreviation] first author, publication year: [B] Bartzokis, 1998; [C] Convit, 1997; [dTM] deToledo-Morrell, 2004; [H] Haller, 1997; [J] Jack, 1994; [K] Killiany, 1993; [L] Lehericy, 1994; [M] Malykhin, 2007; [Pa] Pantel, 2000; [Pr] Pruessner, 2000; [S] Soininen, 1994; [W] Watson, 1992). The hippocampi of one healthy control and one AD patient taken from the 1.5T MR ADNI database were segmented by a single rater according to each protocol. The accuracy of the protocols’ interpretation and translation into practice was checked with lead authors of protocols through individual interactive web conferences. Semantically harmonized landmarks and differences were then extracted, regarding: (a) the posteriormost slice, protocol [B] being the most restrictive, and [H, M, Pa, Pr, S] the most inclusive; (b) inclusion [C, dTM, J, L, M, Pr, W] or exclusion [B, H, K, Pa, S] of alveus/fimbria; (c) separation from the parahippocampal gyrus, [C] being the most restrictive, [B, dTM, H, J, Pa, S] the most inclusive. There were no substantial differences in the definition of the anteriormost slice. This survey will allow us to operationalize differences among protocols into tracing units, measure their impact on the repeatability and diagnostic accuracy of manual hippocampal segmentation, and finally develop a harmonized protocol. PMID:21971451

  13. Evidence-based protocol for structural rehabilitation of the spine and posture: review of clinical biomechanics of posture (CBP®) publications

    PubMed Central

    Oakley, Paul A.; Harrison, Donald D.; Harrison, Deed E.; Haas, Jason W.

    2005-01-01

    BACKGROUND Although practice protocols exist for SMT and functional rehabilitation, no practice protocols exist for structural rehabilitation. Traditional chiropractic practice guidelines have been limited to acute and chronic pain treatment, with limited inclusion of functional and exclusion of structural rehabilitation procedures. OBJECTIVE (1) To derive an evidence-based practice protocol for structural rehabilitation from publications on Clinical Biomechanics of Posture (CBP®) methods, and (2) to compare the evidence for Diversified, SMT, and CBP®. METHODS Clinical control trials utilizing CBP® methods and spinal manipulative therapy (SMT) were obtained from searches in Mantis, CINAHL, and Index Medicus. Using data from SMT review articles, evidence for Diversified Technique (as taught in chiropractic colleges), SMT, and CBP® were rated and compared. RESULTS From the evidence from Clinical Control Trials on SMT and CBP®, there is very little evidence support for Diversified (our rating = 18), as taught in chiropractic colleges, for the treatment of pain subjects, while CBP® (our rating = 46) and SMT for neck pain (rating = 58) and low back pain (our rating = 202) have evidence-based support. CONCLUSIONS While CBP® Technique has approximately as much evidence-based support as SMT for neck pain, CBP® has more evidence to support its methods than the Diversified technique taught in chiropractic colleges, but not as much as SMT for low back pain. The evolution of chiropractic specialization has occurred, and doctors providing structural-based chiropractic care require protocol guidelines for patient quality assurance and standardization. A structural rehabilitation protocol was developed based on evidence from CBP® publications. PMID:17549209

  14. Tuberculose péritonéale pseudo tumorale mimant un cancer ovarien: un diagnostic différentiel important à considérer

    PubMed Central

    Moukit, Mounir; Fadel, Fatimazahra Ait El; Kouach, Jaouad; Babahabib, Abdellah; Dehayni, Mohammed; Rahali, Driss Moussaoui

    2016-01-01

    La tuberculose est une maladie infectieuse curable qui peut simuler dans sa localisation péritonéale un cancer ovarien avancé conduisant ainsi à une chirurgie étendue et inutile souvent chez des femmes en âge de reproduction. Nous rapportons un nouveau cas de tuberculose péritonéale pseudo tumorale chez une patiente âgée de 43 ans chez qui le diagnostic d’un cancer ovarien avec carcinose péritonéale avait été suspecté. La laparotomie exploratrice avec examen histologique extemporané ont permis de confirmer le diagnostic de tuberculose péritonéale. La patiente a bien répondu au traitement antituberculeux selon le protocole 2ERHZ/4RH. PMID:28292155

  15. Protocol for selecting ASR-affected structures for lithium treatment

    DOT National Transportation Integrated Search

    2006-02-01

    This TechBrief describes a protocol for evaluating damaged concrete structures to determine whether they are suitable candidates for lithium treatment to address alkali-silica reactivity (ASR). A major part of the TechBrief's source document, Protoco...

  16. The use of parallel imaging for MRI assessment of knees in children and adolescents.

    PubMed

    Doria, Andrea S; Chaudry, Gulraiz A; Nasui, Cristina; Rayner, Tammy; Wang, Chenghua; Moineddin, Rahim; Babyn, Paul S; White, Larry M; Sussman, Marshall S

    2010-03-01

    Parallel imaging provides faster scanning at the cost of reduced signal-to-noise ratio (SNR) and increased artifacts. To compare the diagnostic performance of two parallel MRI protocols (PPs) for assessment of pathologic knees using an 8-channel knee coil (reference standard, conventional protocol [CP]) and to characterize the SNR losses associated with parallel imaging. Two radiologists blindly interpreted 1.5 Tesla knee MRI images in 21 children (mean 13 years, range 9-18 years) with clinical indications for an MRI scan. Sagittal proton density, T2-W fat-saturated FSE, axial T2-W fat-saturated FSE, and coronal T1-W (NEX of 1,1,1) images were obtained with both CP and PP. Images were read for soft tissue and osteochondral findings. There was a 75% decrease in acquisition time using PP in comparison to CP. The CP and PP protocols fell within excellent or upper limits of substantial agreement: CP, kappa coefficient, 0.81 (95% CIs, 0.73-0.89); PP, 0.80-0.81 (0.73-0.89). The sensitivity of the two PPs was similar for assessment of soft (0.98-1.00) and osteochondral (0.89-0.94) tissues. Phantom data indicated an SNR of 1.67, 1.6, and 1.51 (axial, sagittal and coronal planes) between CP and PP scans. Parallel MRI provides a reliable assessment for pediatric knees in a significantly reduced scan time without affecting the diagnostic performance of MRI.

  17. Diagnosis of colorectal cancer using Raman spectroscopy of laser-trapped single living epithelial cells

    NASA Astrophysics Data System (ADS)

    Chen, Kun; Qin, Yejun; Zheng, Feng; Sun, Menghong; Shi, Daren

    2006-07-01

    A single-cell diagnostic technique for epithelial cancers is developed by utilizing laser trapping and Raman spectroscopy to differentiate cancerous and normal epithelial cells. Single-cell suspensions were prepared from surgically removed human colorectal tissues following standard primary culture protocols and examined in a near-infrared laser-trapping Raman spectroscopy system, where living epithelial cells were investigated one by one. A diagnostic model was built on the spectral data obtained from 8 patients and validated by the data from 2 new patients. Our technique has potential applications from epithelial cancer diagnosis to the study of cell dynamics of carcinogenesis.

  18. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    PubMed

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  19. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective

    PubMed Central

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes. PMID:29138741

  20. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective.

    PubMed

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.

  1. Identification of segregated regions in the functional brain connectome of autistic patients by a combination of fuzzy spectral clustering and entropy analysis

    PubMed Central

    Sato, João Ricardo; Balardin, Joana; Vidal, Maciel Calebe; Fujita, André

    2016-01-01

    Background Several neuroimaging studies support the model of abnormal development of brain connectivity in patients with autism-spectrum disorders (ASD). In this study, we aimed to test the hypothesis of reduced functional network segregation in autistic patients compared with controls. Methods Functional MRI data from children acquired under a resting-state protocol (Autism Brain Imaging Data Exchange [ABIDE]) were submitted to both fuzzy spectral clustering (FSC) with entropy analysis and graph modularity analysis. Results We included data from 814 children in our analysis. We identified 5 regions of interest comprising the motor, temporal and occipito-temporal cortices with increased entropy (p < 0.05) in the clustering structure (i.e., more segregation in the controls). Moreover, we noticed a statistically reduced modularity (p < 0.001) in the autistic patients compared with the controls. Significantly reduced eigenvector centrality values (p < 0.05) in the patients were observed in the same regions that were identified in the FSC analysis. Limitations There is considerable heterogeneity in the fMRI acquisition protocols among the sites that contributed to the ABIDE data set (e.g., scanner type, pulse sequence, duration of scan and resting-state protocol). Moreover, the sites differed in many variables related to sample characterization (e.g., age, IQ and ASD diagnostic criteria). Therefore, we cannot rule out the possibility that additional differences in functional network organization would be found in a more homogeneous data sample of individuals with ASD. Conclusion Our results suggest that the organization of the whole-brain functional network in patients with ASD is different from that observed in controls, which implies a reduced modularity of the brain functional networks involved in sensorimotor, social, affective and cognitive processing. PMID:26505141

  2. Remote control of the industry processes. POWERLINK protocol application

    NASA Astrophysics Data System (ADS)

    Wóbel, A.; Paruzel, D.; Paszkiewicz, B.

    2017-08-01

    The present technological development enables the use of solutions characterized by a lower failure rate, and work with greater precision. This allows you to obtain the most efficient production, high speed production and reliability of individual components. The main scope of this article was POWERLINK protocol application for communication with the controller B & R through communication Ethernet for recording process parameters. This enables control of run production cycle using an internal network connected to the PC industry. Knowledge of the most important parameters of the production in real time allows detecting of a failure immediately after occurrence. For this purpose, the position of diagnostic use driver X20CP1301 B&R to record measurement data such as pressure, temperature valve between the parties and the torque required to change the valve setting was made. The use of POWERLINK protocol allows for the transmission of information on the status of every 200 μs.

  3. Measurement of pulmonary arterial impedance and reflection from single-slice phase-contrast and steady-state free precession MRI

    NASA Astrophysics Data System (ADS)

    Leimbigler, Peter John

    Pulmonary arterial hypertension (PAH) alters vessel wall mechanics and vasomotor tone, driving up pulmonary hemodynamic variables such as pulse wave velocity, input and characteristic impedance, and pulse wave reflection magnitude. Heterogeneous treatment response necessitates frequent hemodynamic evaluation, for which right-heart catheterization (RHC) remains the gold standard; however, several disadvantages limit its frequency of use. In this work, a non-invasive magnetic resonance (MR) imaging protocol is developed to address the shortcomings of invasive hemodynamic monitoring and may support existing diagnostic procedures. First, accuracy and precision of the proposed method is characterized through linear uncertainty propagation and numerical simulation of the data-processing pipeline. Second, the MR protocol is tested in seven healthy adult volunteers. Third, a rapid version of the MR protocol is tested in a healthy volunteer, yielding good agreement with mean values obtained in the seven-volunteer study.

  4. Meeting The Joint Commission's Dose Incident Identification and External Benchmarking Requirements Using the ACR's Dose Index Registry.

    PubMed

    Bohl, Michael A; Goswami, Roopa; Strassner, Brett; Stanger, Paula

    2016-08-01

    The purpose of this investigation was to evaluate the potential of using the ACR's Dose Index Registry(®) to meet The Joint Commission's requirements to identify incidents in which the radiation dose index from diagnostic CT examinations exceeded the protocol's expected dose index range. In total, 10,970 records in the Dose Index Registry were statistically analyzed to establish both an upper and lower expected dose index for each protocol. All 2015 studies to date were then retrospectively reviewed to identify examinations whose total examination dose index exceeded the protocol's defined upper threshold. Each dose incident was then logged and reviewed per the new Joint Commission requirements. Facilities may leverage their participation in the ACR's Dose Index Registry to fully meet The Joint Commission's dose incident identification review and external benchmarking requirements. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Department of Defense picture archiving and communication system acceptance testing: results and identification of problem components.

    PubMed

    Allison, Scott A; Sweet, Clifford F; Beall, Douglas P; Lewis, Thomas E; Monroe, Thomas

    2005-09-01

    The PACS implementation process is complicated requiring a tremendous amount of time, resources, and planning. The Department of Defense (DOD) has significant experience in developing and refining PACS acceptance testing (AT) protocols that assure contract compliance, clinical safety, and functionality. The DOD's AT experience under the initial Medical Diagnostic Imaging Support System contract led to the current Digital Imaging Network-Picture Archiving and Communications Systems (DIN-PACS) contract AT protocol. To identify the most common system and component deficiencies under the current DIN-PACS AT protocol, 14 tri-service sites were evaluated during 1998-2000. Sixteen system deficiency citations with 154 separate types of limitations were noted with problems involving the workstation, interfaces, and the Radiology Information System comprising more than 50% of the citations. Larger PACS deployments were associated with a higher number of deficiencies. The most commonly cited systems deficiencies were among the most expensive components of the PACS.

  6. Coronal and Prominence Plasmas

    NASA Technical Reports Server (NTRS)

    Poland, Arthur I. (Editor)

    1986-01-01

    Various aspects of solar prominences and the solar corona are discussed. The formation of prominences, prominence diagnostics and structure, prominence dissappearance, large scale coronal structure, coronal diagnostics, small scale coronal structure, and non-equilibrium/coronal heating are among the topics covered.

  7. Assessment of Diverse Biological Indicators in Gulf War Illness: Are They Replicable Are They Related

    DTIC Science & Technology

    2016-04-01

    compared to 50 healthy veteran controls in a protocol that includes physical and neuropsychological evaluations, neuroimaging (MRI, fMRI, DTI), adrenal...SUBJECT TERMS Gulf War illness, neuroimaging, neuropsychological testing, immune function, hypothalamic-pituitary-adrenal testing 16. SECURITY... neuropsychological evaluations, assessment of hypothalamic-pituitary-adrenal function, standard clinical diagnostic laboratory tests, and research

  8. [Idiopathic gynecomastia: our experience].

    PubMed

    Barbuscia, M; Di Pietro, N; Rizzo, A G; Catalfamo, A; Melita, G; Sanò, M; Mancuso, V; Gorgone, S

    2003-04-01

    The Authors reporting their experience, discuss some concepts about physiologic evolution of male and female breast. They distinguish between real and false gynaecomastia; stressing the causes of abnormal development of male breast and morphopathological characteristics of gynaecomastia. Careful diagnostic protocol is necessary for a therapeutic approach based on traditional surgery or liposuction: it depends on prevalence of glandular or adipose breast's tissue.

  9. Complete radiotherapy response in rectal cancer: A review of the evidence.

    PubMed

    Couch, Daniel G; Hemingway, David M

    2016-01-14

    Complete response to chemoradiotherapy for rectal cancer is becoming a common clinical entity. Techniques to diagnose complete response and how to survey these patients without operative intervention are still unclear. We review the most recent evidence. Barriers to firm conclusions regarding this are heterogeneity of diagnostic definitions, differing surveillance protocols, and a lack of randomised studies.

  10. The Rockefeller University Navigation Program: A Structured Multidisciplinary Protocol Development and Educational Program to Advance Translational Research

    PubMed Central

    Kost, Rhonda G.; Dowd, Kathleen A.; Hurley, Arlene M.; Rainer, Tyler‐Lauren; Coller, Barry S.

    2014-01-01

    Abstract The development of translational clinical research protocols is complex. To assist investigators, we developed a structured supportive guidance process (Navigation) to expedite protocol development to the standards of good clinical practice (GCP), focusing on research ethics and integrity. Navigation consists of experienced research coordinators leading investigators through a concerted multistep protocol development process from concept initiation to submission of the final protocol. To assess the effectiveness of Navigation, we collect data on the experience of investigators, the intensity of support required for protocol development, IRB review outcomes, and protocol start and completion dates. One hundred forty‐four protocols underwent Navigation and achieved IRB approval since the program began in 2007, including 37 led by trainee investigators, 26 led by MDs, 9 by MD/PhDs, 57 by PhDs, and 12 by investigators with other credentials (e.g., RN, MPH). In every year, more than 50% of Navigated protocols were approved by the IRB within 30 days. For trainees who had more than one protocol navigated, the intensity of Navigation support required decreased over time. Navigation can increase access to translational studies for basic scientists, facilitate GCP training for investigators, and accelerate development and approval of protocols of high ethical and scientific quality. PMID:24405608

  11. Optimising μCT imaging of the middle and inner cat ear.

    PubMed

    Seifert, H; Röher, U; Staszyk, C; Angrisani, N; Dziuba, D; Meyer-Lindenberg, A

    2012-04-01

    This study's aim was to determine the optimal scan parameters for imaging the middle and inner ear of the cat with micro-computertomography (μCT). Besides, the study set out to assess whether adequate image quality can be obtained to use μCT in diagnostics and research on cat ears. For optimisation, μCT imaging of two cat skull preparations was performed using 36 different scanning protocols. The μCT-scans were evaluated by four experienced experts with regard to the image quality and detail detectability. By compiling a ranking of the results, the best possible scan parameters could be determined. From a third cat's skull, a μCT-scan, using these optimised scan parameters, and a comparative clinical CT-scan were acquired. Afterwards, histological specimens of the ears were produced which were compared to the μCT-images. The comparison shows that the osseous structures are depicted in detail. Although soft tissues cannot be differentiated, the osseous structures serve as valuable spatial orientation of relevant nerves and muscles. Clinical CT can depict many anatomical structures which can also be seen on μCT-images, but these appear a lot less sharp and also less detailed than with μCT. © 2011 Blackwell Verlag GmbH.

  12. Effects of immediate and delayed loading on peri-implant trabecular structures: a cone beam CT evaluation.

    PubMed

    Huang, Yan; Van Dessel, Jeroen; Liang, Xin; Depypere, Maarten; Zhong, Weijian; Ma, Guowu; Lambrichts, Ivo; Maes, Frederik; Jacobs, Reinhilde

    2014-12-01

    To develop a method for characterizing trabecular bone microarchitecture using cone beam computed tomography (CBCT) and to evaluate trabecular bone changes after rehabilitation using immediate versus delayed implant protocols. Six mongrel dogs randomly received 27 titanium implants in the maxillary incisor or mandibular premolar areas, following one of four protocols: (1) normal extraction socket healing; (2) immediate implant placement and immediate loading; (3) delayed implant placement and delayed loading; (4) delayed implant placement and immediate loading. The animals were euthanized at 8 weeks, and block biopsies were scanned using high resolution CBCT. Standard bone structural variables were assessed in coronal, middle, and apical levels. Coronal and middle regions had more compact, more platelike, and thicker trabeculae. Protocols (2), (3), and (4) had significantly higher values (p < 0.001) than protocol (1) for bone surface density, bone surface volume ratio, and connectivity density, while significantly lower values (p < 0.001) were found for trabecular separation and fractal dimension. However, protocols (2), (3), and (4) did not show significantly different bone remodeling. Compared with normal extraction healing, the implant protocols have an improved bone structural integration. Results do not suggest a different bone remodeling pattern when a delayed versus an immediate implant protocol is used. © 2013 Wiley Periodicals, Inc.

  13. Protocol for HER2 FISH determination on PAXgene-fixed and paraffin-embedded tissue in breast cancer.

    PubMed

    Oberauner-Wappis, Lisa; Loibner, Martina; Viertler, Christian; Groelz, Daniel; Wyrich, Ralf; Zatloukal, Kurt

    2016-04-01

    Molecular diagnostics in personalized medicine increasingly relies on the combination of a variety of analytical technologies to characterize individual diseases and to select patients for targeted therapies. The gold standard for tissue-based diagnostics is fixation in formalin and embedding in paraffin, which results in excellent preservation of morphology but negatively impacts on a variety of molecular assays. The formalin-free, non-cross-linking PAXgene tissue system preserves morphology in a similar way to formalin, but also preserves biomolecules essentially in a similar way to cryopreservation, which markedly widens the spectrum, sensitivity and accuracy of molecular analytics. In this study, we have developed and tested a protocol for PAXgene-fixed and paraffin-embedded tissues for fluorescent in situ hybridization (FISH). The implementation of a 24-h formalin postfixation step of slides from PAXgene-fixed and paraffin-embedded tissues allowed us to use the assays approved for formalin-fixed and paraffin-embedded tissues. The equivalence of the methodologies was demonstrated by FISH analysis of HER2 amplification in breast cancer cases. The 24-h postfixation step of the slides used for FISH can be well integrated in the routine diagnostic workflow and allows the remaining PAXgene-fixed and paraffin-embedded tissue to be used for further molecular testing. © 2016 The Authors. International Journal of Experimental Pathology published by John Wiley & Sons Ltd on behalf of Company of the International Journal of Experimental Pathology (CIJEP).

  14. Oriented conjugates of monoclonal and single-domain antibodies with quantum dots for flow cytometry and immunohistochemistry diagnostic applications

    NASA Astrophysics Data System (ADS)

    Sukhanova, Alyona; Even-Desrumeaux, Klervi; Millot, Jean-Marc; Chames, Patrick; Baty, Daniel; Artemyev, Mikhail; Oleinikov, Vladimir; Cohen, Jacques H. M.; Nabiev, Igor

    2012-03-01

    Ideal diagnostic nanoprobes should not exceed 15 nm in size and should contain high-affinity homogeneously oriented capture molecules on their surface. An advanced procedure for antibody (Ab) reduction was used to cleave each Ab into two functional half-Abs, 75-kDa heavy-light chain fragments, each containing an intact antigen-binding site. Affinity purification of half-Abs followed by their linkage to quantum dots (QDs) yielded oriented QD-Ab conjugates whose functionality was considerably improved compared to those obtained using the standard protocols. Ultrasmall diagnostic nanoprobes were engineered through oriented conjugation of QDs with 13-kDa single-domain Abs (sdAbs) derived from llama IgG. sdAbs were tagged with QDs via an additional cysteine residue specifically integrated into the C-terminal region of sdAb using genetic engineering. This approach made it possible to obtain sdAb-QD nanoprobes <12 nm in diameter comprising four copies of sdAbs linked to the same QD in an oriented manner. sdAb-QD conjugates against carcinoembryonic antigen (CEA) and HER2 exhibited an extremely high specificity in flow cytometry; the quality of immunohistochemical labeling of biopsy samples was found to be superior to that of labeling according to the current "gold standard" protocols of anatomo-pathological practice. The nano-bioengineering approaches developed can be extended to oriented conjugation of Abs and sdAbs with different semiconductor, noble metal, or magnetic nanoparticles.

  15. Early hearing detection and intervention: 2010 CODEPEH recommendation.

    PubMed

    Trinidad-Ramos, Germán; de Aguilar, Valentín Alzina; Jaudenes-Casaubón, Carmen; Núñez-Batalla, Faustino; Sequí-Canet, José Miguel

    2010-01-01

    Newborn hearing screening is currently performed routinely in many regional health-care systems in Spain. Despite the remarkable expansion in newborn hearing screening since 2000, its feasibility and the benefits of early identification and intervention, many major challenges still remain. In this article, the Committee for the Early Detection of Hearing Loss (Comisión para la Detección Precoz de la Hipoacusia, CODEPEH) updates the recommendations that are considered important for the future development of early hearing detection and intervention (EDHI) systems in the following points: 1. Screening protocols: Separate protocols are recommended for NICU (Neonatal Intensive Care Units) and well-infant nurseries. 2. Diagnostic audiology evaluation. Professionals with skills and expertise in evaluating newborn and young infants should provide diagnosis, selection and fitting of amplification devices. 3. Medical evaluation. Risk factors for congenital and acquired hearing loss have been combined in a single list rather than grouped by time of onset. A stepwise diagnostic paradigm is diagnostically more efficient and cost-effective than a simultaneous testing approach. 4. Early intervention and surveillance. All individuals providing services to infants with hearing loss should have specialized training and expertise in the development of audition, speech and language. Regular surveillance should be performed on developmental milestones, auditory skills, parental concerns, and middle ear status. 5. Quality control. Data management as part of an integrated system is important to monitor and improve the quality of EDHI services. 2009 Elsevier España, S.L. All rights reserved.

  16. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block.

    PubMed

    Cabeda, Estêvan Vieira; Falcão, Andréa Maria Gomes; Soares, José; Rochitte, Carlos Eduardo; Nomura, César Higa; Ávila, Luiz Francisco Rodrigues; Parga, José Rodrigues

    2015-12-01

    Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution's ethics committee. The patients' mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

  17. Wireless networking for the dental office: current wireless standards and security protocols.

    PubMed

    Mupparapu, Muralidhar; Arora, Sarika

    2004-11-15

    Digital radiography has gained immense popularity in dentistry today in spite of the early difficulty for the profession to embrace the technology. The transition from film to digital has been happening at a faster pace in the fields of Orthodontics, Oral Surgery, Endodontics, Periodontics, and other specialties where the radiographic images (periapical, bitewing, panoramic, cephalometric, and skull radiographs) are being acquired digitally, stored within a server locally, and eventually accessed for diagnostic purposes, along with the rest of the patient data via the patient management software (PMS). A review of the literature shows the diagnostic performance of digital radiography is at least comparable to or even better than that of conventional radiography. Similarly, other digital diagnostic tools like caries detectors, cephalometric analysis software, and digital scanners were used for many years for the diagnosis and treatment planning purposes. The introduction of wireless charged-coupled device (CCD) sensors in early 2004 (Schick Technologies, Long Island City, NY) has moved digital radiography a step further into the wireless era. As with any emerging technology, there are concerns that should be looked into before adapting to the wireless environment. Foremost is the network security involved in the installation and usage of these wireless networks. This article deals with the existing standards and choices in wireless technologies that are available for implementation within a contemporary dental office. The network security protocols that protect the patient data and boost the efficiency of modern day dental clinics are enumerated.

  18. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    PubMed

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage†

    PubMed Central

    Borthakur, Arijitt; Mellon, Eric; Niyogi, Sampreet; Witschey, Walter; Kneeland, J. Bruce; Reddy, Ravinder

    2010-01-01

    In this article, both sodium magnetic resonance (MR) and T1ρ relaxation mapping aimed at measuring molecular changes in cartilage for the diagnostic imaging of osteoarthritis are reviewed. First, an introduction to structure of cartilage, its degeneration in osteoarthritis (OA) and an outline of diagnostic imaging methods in quantifying molecular changes and early diagnostic aspects of cartilage degeneration are described. The sodium MRI section begins with a brief overview of the theory of sodium NMR of biological tissues and is followed by a section on multiple quantum filters that can be used to quantify both bi-exponential relaxation and residual quadrupolar interaction. Specifically, (i) the rationale behind the use of sodium MRI in quantifying proteoglycan (PG) changes, (ii) validation studies using biochemical assays, (iii) studies on human OA specimens, (iv) results on animal models and (v) clinical imaging protocols are reviewed. Results demonstrating the feasibility of quantifying PG in OA patients and comparison with that in healthy subjects are also presented. The section concludes with the discussion of advantages and potential issues with sodium MRI and the impact of new technological advancements (e.g. ultra-high field scanners and parallel imaging methods). In the theory section on T1ρ, a brief description of (i) principles of measuring T1ρ relaxation, (ii) pulse sequences for computing T1ρ relaxation maps, (iii) issues regarding radio frequency power deposition, (iv) mechanisms that contribute to T1ρ in biological tissues and (v) effects of exchange and dipolar interaction on T1ρ dispersion are discussed. Correlation of T1ρ relaxation rate with macromolecular content and biomechanical properties in cartilage specimens subjected to trypsin and cytokine-induced glycosaminoglycan depletion and validation against biochemical assay and histopathology are presented. Experimental T1ρ data from osteoarthritic specimens, animal models, healthy human subjects and as well from osteoarthritic patients are provided. The current status of T1ρ relaxation mapping of cartilage and future directions is also discussed. PMID:17075961

  20. Study protocol of the internet user Cohort for Unbiased Recognition of gaming disorder in Early adolescence (iCURE), Korea, 2015-2019.

    PubMed

    Jeong, Hyunsuk; Yim, Hyeon Woo; Jo, Sun-Jin; Lee, Seung-Yup; Kim, Eunjin; Son, Hye Jung; Han, Hyun-Ho; Lee, Hae Kook; Kweon, Yong-Sil; Bhang, Soo-Young; Choi, Jung-Seok; Kim, Bung-Nyun; Gentile, Douglas A; Potenza, Marc N

    2017-10-05

    In 2013, the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) proposed nine internet gaming disorder (IGD) diagnostic criteria as a condition warranting further empirical and clinical research. The aim of this study is to clarify the natural and clinical courses of IGD proposed DSM-5 in adolescents and to evaluate its risk and protective factors. The Internet user Cohort for Unbiased Recognition of gaming disorder in Early Adolescence (iCURE) study is an ongoing multidisciplinary, prospective, longitudinal cohort study conducted in 21 schools in Korea. Participant recruitment commenced in March 2015 with the goal of registering 3000 adolescents. The baseline assessment included surveys on emotional, social and environmental characteristics. A parent or guardian completed questionnaires and a structured psychiatric comorbidity diagnostic interview regarding their children. Adolescents with the Internet Game Use-Elicited Symptom Screen total scores of 6 or higher were asked to participate in the clinical diagnostic interview. Two subcohorts of adolescents were constructed: a representative subcohort and a clinical evaluation subcohort. The representative subcohort comprises a randomly selected 10% of the iCURE to investigate the clinical course of IGD based on clinical diagnosis and to estimate the false negative rate. The clinical evaluation subcohort comprised participants meeting three or more of the nine IGD criteria, determined by clinical diagnostic interview, to show the clinical course of IGD. Follow-up data will be collected annually for the 3 years following the baseline assessments. The primary endpoint is 2-year incidence, remission and recurrence rates of IGD. Cross-sectional and longitudinal associations between exposures and outcomes as well as mediation factors will be evaluated. This study is approved by the Institutional Review Board of the Catholic University of Korea. Results will be published in peer-reviewed journals. ClinicalTrials.gov (identifier: NCT02415322). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Structure and Computation in Immunoreagent Design: From Diagnostics to Vaccines.

    PubMed

    Gourlay, Louise; Peri, Claudio; Bolognesi, Martino; Colombo, Giorgio

    2017-12-01

    Novel immunological tools for efficient diagnosis and treatment of emerging infections are urgently required. Advances in the diagnostic and vaccine development fields are continuously progressing, with reverse vaccinology and structural vaccinology (SV) methods for antigen identification and structure-based antigen (re)design playing increasingly relevant roles. SV, in particular, is predicted to be the front-runner in the future development of diagnostics and vaccines targeting challenging diseases such as AIDS and cancer. We review state-of-the-art methodologies for structure-based epitope identification and antigen design, with specific applicative examples. We highlight the implications of such methods for the engineering of biomolecules with improved immunological properties, potential diagnostic and/or therapeutic uses, and discuss the perspectives of structure-based rational design for the production of advanced immunoreagents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. The use of plant community attributes to detect habitat quality in coastal environments

    PubMed Central

    Del Vecchio, Silvia; Slaviero, Antonio; Fantinato, Edy; Buffa, Gabriella

    2016-01-01

    The monitoring of biodiversity has mainly focused on the species level. However, researchers and land managers are making increasing use of complementary assessment tools that address higher levels of biological organization, i.e. communities, habitats and ecosystems. Recently, a variety of frameworks have been proposed for assessing the conservation status of communities or ecosystems. Among the various criteria proposed, all the protocols suggest considering (i) spatial aspects (range and area), and (ii) qualitative aspects of specific structures and functions. However, changes to ecological function are difficult to quantify and many protocols end up by using qualitative criteria. The aim of this work was to test the efficacy of some plant community attributes for the detection of vegetation quality in sand dune plant communities. We chose plant community attributes that either help to distinguish a habitat from others (diagnostic components) or play a significant role in habitat function and persistence over time. We used a diachronic approach by contrasting up-to-date vegetation data with data from previous studies carried out within the same areas. Changes in species composition were detected through detrended correspondence analyses (detrended correspondence analyses), Multi-Response Permutation Procedures and Indicator Species Analysis, while structural changes were analyzed by comparing species richness, total species cover, ecological groups of species and growth forms through null models. Ecological groups such as native focal species and aliens, and growth forms proved their efficacy in discriminating between habitat types and in describing their changes over time. The approach used in this study may provide an instrument for the assessment of plant community quality that can be applied to other coastal ecosystems. PMID:27255516

  3. [Protocols for the health surveillance of fisherman].

    PubMed

    Soleo, Leonardo; Cannizzaro, Emanuele; Lovreglio, Piero; Basso, Antonella; D'Errico, Maria Nicolà; Pira, Enrico

    2013-01-01

    To define protocols for health surveillance of workers in the marine fishing sector for specific occupational risk factors, considering the latest and most advanced scientific knowledge. The specific literature was analyzed to identify the occupational risk factors to which fishermen are exposed. Then, for each risk factor a protocol for the relative health checkups and their time schedule was defined. The risk factors to which fishermen are exposed are essentially noise, vibrations, solar and ultraviolet radiation, climatic agents (heat, cold, wind, rain, damp), chemical agents, shifts, work rate, night work, physical strain, stress, manual handling of loads, upper limb repetitive tasks, incongruous postures. The health protocols stipulate the health screening investigations to be carried out in all workers of a homogeneous group, and in-depth diagnostic investigations to be carried out in symptomatic workers. Complementary health investigations must be focused on a functional exploration of the organs specifically exposed to the risk factor. For hearing impairments due to noise exposure, the medico-legal measures with which the occupational health physician must comply, in cases of occupational disease, are indicated.

  4. Post-Traumatic Stress Disorder in Maltreated Youth: A Study of Diagnostic Comorbidity and Child Factors

    ERIC Educational Resources Information Center

    Linning, Lisa M.; Kearney, Christopher A.

    2004-01-01

    The study of post-traumatic stress disorder (PTSD) in maltreated youth has received increased attention, though extensive comparisons to maltreated youth without PTSD and administrations of anxiety-based structured diagnostic interviews remain needed. We examined maltreated youth with or without PTSD using structured diagnostic interviews and…

  5. Computed Tomography of the Abdomen in Eight Clinically Normal Common Marmosets (Callithrix jacchus).

    PubMed

    du Plessis, W M; Groenewald, H B; Elliott, D

    2017-08-01

    The aim of this study was to provide a detailed anatomical description of the abdomen in the clinically normal common marmoset by means of computed tomography (CT). Eight clinically healthy mature common marmosets ranging from 12 to 48 months and 235 to 365 g bodyweight were anesthetized and pre- and post-contrast CT examinations were performed using different CT settings in dorsal recumbency. Abdominal organs were identified and visibility noted. Diagnostic quality abdominal images could be obtained of the common marmoset despite its small size using a dual-slice CT scanner. Representative cross-sectional images were chosen from different animals illustrating the abdominal CT anatomy of clinically normal common marmosets. Identification or delineation of abdominal organs greatly improved with i.v. contrast. A modified high-frequency algorithm with edge enhancement added valuable information for identification of small structures such as the ureters. The Hounsfield unit (HU) of major abdominal organs differed from that of small animals (domestic dogs and cats). Due to their size and different anatomy, standard small animal CT protocols need to be critically assessed and adapted for exotics, such as the common marmoset. The established normal reference range of HU of major abdominal organs and adapted settings for a CT protocol will aid clinical assessment of the common marmoset. © 2017 Blackwell Verlag GmbH.

  6. An evaluation of the use of oral contrast media in abdominopelvic CT.

    PubMed

    Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis

    2014-11-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.

  7. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases.

    PubMed

    Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F

    2016-05-01

    To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will targetmore » these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.« less

  9. TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, S.

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will targetmore » these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.« less

  10. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garra, B.

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will targetmore » these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.« less

  11. Visual grading characteristics and ordinal regression analysis during optimisation of CT head examinations.

    PubMed

    Zarb, Francis; McEntee, Mark F; Rainford, Louise

    2015-06-01

    To evaluate visual grading characteristics (VGC) and ordinal regression analysis during head CT optimisation as a potential alternative to visual grading assessment (VGA), traditionally employed to score anatomical visualisation. Patient images (n = 66) were obtained using current and optimised imaging protocols from two CT suites: a 16-slice scanner at the national Maltese centre for trauma and a 64-slice scanner in a private centre. Local resident radiologists (n = 6) performed VGA followed by VGC and ordinal regression analysis. VGC alone indicated that optimised protocols had similar image quality as current protocols. Ordinal logistic regression analysis provided an in-depth evaluation, criterion by criterion allowing the selective implementation of the protocols. The local radiology review panel supported the implementation of optimised protocols for brain CT examinations (including trauma) in one centre, achieving radiation dose reductions ranging from 24 % to 36 %. In the second centre a 29 % reduction in radiation dose was achieved for follow-up cases. The combined use of VGC and ordinal logistic regression analysis led to clinical decisions being taken on the implementation of the optimised protocols. This improved method of image quality analysis provided the evidence to support imaging protocol optimisation, resulting in significant radiation dose savings. • There is need for scientifically based image quality evaluation during CT optimisation. • VGC and ordinal regression analysis in combination led to better informed clinical decisions. • VGC and ordinal regression analysis led to dose reductions without compromising diagnostic efficacy.

  12. Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

    PubMed

    De Bondt, Timo; Mulkens, Tom; Zanca, Federica; Pyfferoen, Lotte; Casselman, Jan W; Parizel, Paul M

    2017-02-01

    To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters. Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to automatically gather information. Dose (CTDI and DLP), scan length, amount of retakes and demographic data were stratified by age and clinical indication; appropriate use of child-specific protocols was assessed. In total, 296 paediatric cranial CT-procedures were collected. Although the median dose of each hospital was below national and international diagnostic reference level (DRL) for all age categories, statistically significant (p-value < 0.001) dose differences among hospitals were observed. The hospital with lowest dose levels showed smallest dose variability and used age-stratified protocols for standardizing paediatric head exams. Erroneous selection of adult protocols for children still occurred, mostly in the oldest age-group. Even though all hospitals complied with national and international DRLs, dose tracking and benchmarking showed that further dose optimization and standardization is possible by using age-stratified protocols for paediatric cranial CT. Moreover, having a dose tracking system revealed that adult protocols are still applied for paediatric CT, a practice that must be avoided. • Significant differences were observed in the delivered dose between age-groups and hospitals. • Using age-adapted scanning protocols gives a nearly linear dose increase. • Sharing dose-data can be a trigger for hospitals to reduce dose levels.

  13. Truth and lies: Disclosure and the power of diagnosis.

    PubMed

    Jutel, Annemarie

    2016-09-01

    The moment at which a diagnosis is delivered to a patient, particularly when it is serious, is an important social moment. It not only dictates the clinical pathway, it also rewrites the patient narrative, shifts their identity, predicts potential outcomes, and foregrounds mortality. It may provide a sense of relief, or one of despair. Over time, and across cultures, there have been many different approaches used to palliate the potential impact of the diagnostic utterance on the patient. France, as one example, provides an interesting case study. Until the turn of the century, cancer diagnoses were often concealed from patients. However, recent legislation now requires full diagnostic disclosure according to prescribed protocols. Using Zerubavel's social patterning methodology, and transcultural historical methods, I seek to understand beliefs about the potential impact of the diagnostic moment by identifying common features across cultural and historical social contexts. I examine writings of French oncologists, and physicians in related fields, from the pre- and post-legislation era who discuss if and how a cancer diagnosis should be disclosed to the patient. While the approach to diagnostic disclosure has changed significantly, medical representations of diagnostic power have not. The diagnostic utterance is still cast by medical professionals as a terrifying and life-disrupting moment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Effect of Watermarking on Diagnostic Preservation of Atherosclerotic Ultrasound Video in Stroke Telemedicine.

    PubMed

    Dey, Nilanjan; Bose, Soumyo; Das, Achintya; Chaudhuri, Sheli Sinha; Saba, Luca; Shafique, Shoaib; Nicolaides, Andrew; Suri, Jasjit S

    2016-04-01

    Embedding of diagnostic and health care information requires secure encryption and watermarking. This research paper presents a comprehensive study for the behavior of some well established watermarking algorithms in frequency domain for the preservation of stroke-based diagnostic parameters. Two different sets of watermarking algorithms namely: two correlation-based (binary logo hiding) and two singular value decomposition (SVD)-based (gray logo hiding) watermarking algorithms are used for embedding ownership logo. The diagnostic parameters in atherosclerotic plaque ultrasound video are namely: (a) bulb identification and recognition which consists of identifying the bulb edge points in far and near carotid walls; (b) carotid bulb diameter; and (c) carotid lumen thickness all along the carotid artery. The tested data set consists of carotid atherosclerotic movies taken under IRB protocol from University of Indiana Hospital, USA-AtheroPoint™ (Roseville, CA, USA) joint pilot study. ROC (receiver operating characteristic) analysis was performed on the bulb detection process that showed an accuracy and sensitivity of 100 % each, respectively. The diagnostic preservation (DPsystem) for SVD-based approach was above 99 % with PSNR (Peak signal-to-noise ratio) above 41, ensuring the retention of diagnostic parameter devalorization as an effect of watermarking. Thus, the fully automated proposed system proved to be an efficient method for watermarking the atherosclerotic ultrasound video for stroke application.

  15. Structured Transition Protocol for Children with Cystinosis

    PubMed Central

    Raina, Rupesh; Wang, Joseph; Krishnappa, Vinod

    2017-01-01

    The transition from pediatric to adult medical services has a greater impact on the care of adolescents or young adults with chronic diseases such as cystinosis. This transition period is a time of psychosocial development and new responsibilities placing these patients at increased risk of non-adherence. This can lead to serious adverse effects such as graft loss and progression of the disease. Our transition protocol will provide patients, families, physicians, and all those involved a structured guide to transitioning cystinosis patients. This structured protocol depends on four areas of competency: Recognition, Insight, Self-reliance, and Establishment of healthy habits (RISE). This protocol has not been tested and therefore challenges not realized. With a focus on medical, social, and educational/vocational aspects, we aim to improve transition for cystinosis patients in all aspects of their lives. PMID:28913329

  16. Comparison of Head Elevation Protocols Following Femoral Artery Sheath Removal After Coronary Angiography.

    PubMed

    Olson, Nancy C

    2016-06-01

    To compare 2 standard protocols for head elevation following removal of a femoral artery sheath after coronary angiography and their effects on bleeding complications and reported levels of back pain. One protocol involved flat supine bed rest; the other allowed progressive head elevation. A prospective comparative study of 80 adult patients undergoing coronary angiography via the femoral approach. The Numeric Rating Scale was used as the measure of reported pain. No bleeding complications occurred in either group. Both groups had very low mean pain scores. Repeated-measures analysis demonstrated that the experience of pain differed significantly over time by location (F5,70 = 3.864, P = .004), with a notable decrease in pain scores more than 1 hour after sheath removal at the location that used the progressive head elevation protocol. Patients' satisfaction scores after discharge did not differ significantly between the 2 groups. Patients with a history of chronic back pain had consistently higher pain scores, but those pain scores did not differ significantly by location (or protocol). It appears that using a progressive head-elevation protocol within the first 3 hours after diagnostic angiography is not associated with an increased risk of bleeding complications at the access site and warrants further exploration in the mitigation of back pain associated with prolonged supine bed rest. ©2016 American Association of Critical-Care Nurses.

  17. Eliciting improved quantitative judgements using the IDEA protocol: A case study in natural resource management.

    PubMed

    Hemming, Victoria; Walshe, Terry V; Hanea, Anca M; Fidler, Fiona; Burgman, Mark A

    2018-01-01

    Natural resource management uses expert judgement to estimate facts that inform important decisions. Unfortunately, expert judgement is often derived by informal and largely untested protocols, despite evidence that the quality of judgements can be improved with structured approaches. We attribute the lack of uptake of structured protocols to the dearth of illustrative examples that demonstrate how they can be applied within pressing time and resource constraints, while also improving judgements. In this paper, we demonstrate how the IDEA protocol for structured expert elicitation may be deployed to overcome operational challenges while improving the quality of judgements. The protocol was applied to the estimation of 14 future abiotic and biotic events on the Great Barrier Reef, Australia. Seventy-six participants with varying levels of expertise related to the Great Barrier Reef were recruited and allocated randomly to eight groups. Each participant provided their judgements using the four-step question format of the IDEA protocol ('Investigate', 'Discuss', 'Estimate', 'Aggregate') through remote elicitation. When the events were realised, the participant judgements were scored in terms of accuracy, calibration and informativeness. The results demonstrate that the IDEA protocol provides a practical, cost-effective, and repeatable approach to the elicitation of quantitative estimates and uncertainty via remote elicitation. We emphasise that i) the aggregation of diverse individual judgements into pooled group judgments almost always outperformed individuals, and ii) use of a modified Delphi approach helped to remove linguistic ambiguity, and further improved individual and group judgements. Importantly, the protocol encourages review, critical appraisal and replication, each of which is required if judgements are to be used in place of data in a scientific context. The results add to the growing body of literature that demonstrates the merit of using structured elicitation protocols. We urge decision-makers and analysts to use insights and examples to improve the evidence base of expert judgement in natural resource management.

  18. Esthetic Rehabilitation of Anterior Teeth with Laminates Composite Veneers

    PubMed Central

    Riva, Giancarlo

    2014-01-01

    No- or minimal-preparation veneers associated with enamel preservation offer predictable results in esthetic dentistry; indirect additive anterior composite restorations represent a quick, minimally invasive, inexpensive, and repairable option for a smile enhancement treatment plan. Current laboratory techniques associated with a strict clinical protocol satisfy patients' restorative and esthetic needs. The case report presented describes minimal invasive treatment of four upper incisors with laminate nanohybrid resin composite veneers. A step-by-step protocol is proposed for diagnostic evaluation, mock-up fabrication and trial, teeth preparation and impression, and adhesive cementation. The resolution of initial esthetic issues, patient satisfaction, and nice integration of indirect restorations confirmed the success of this anterior dentition rehabilitation. PMID:25013730

  19. Effects of different duration isometric contractions on tendon elasticity in human quadriceps muscles

    PubMed Central

    Kubo, Keitaro; Kanehisa, Hiroaki; Fukunaga, Tetsuo

    2001-01-01

    The present study aimed to investigate the influence of isometric training protocols with long- and short-duration contractions on the elasticity of human tendon structures in vivo. The elasticity was assessed through in vivo determination of the elongation (L) of the tendons and aponeuroses using ultrasonography, while the subjects performed ramp isometric exercise up to maximum voluntary contraction (MVC).Eight young males completed 12 weeks (4 days per week) of a unilateral isometric training programme on knee extensors, which consisted of two different combinations of contraction and relaxation times at 70 % MVC: one leg was trained using a short-duration protocol (3 sets of 50 repetitions of contraction for 1 s and relaxation for 2 s), and the other leg was trained using a long-duration protocol (4 sets of a combination of contraction for 20 s and relaxation for 1 min). The training volume per session, expressed as the integrated torque, was the same for the two protocols.Both protocols resulted in a significant increase in MVC: 31.8 ± 17.2 % for the short-duration protocol and 33.9 ± 14.4 % for the long-duration protocol. Moreover, the training produced significant increases in the muscle volume of the constituents of the quadriceps femoris, with similar relative gains for the two protocols: 7.4 ± 3.9 % for the short-duration protocol and 7.6 ± 4.3 % for the long-duration protocol.The short-duration protocol produced no significant change in L values at any of the force production levels. For the long-duration protocol, however, the L values above 550 N were significantly shorter after training. Analysis revealed that the group × test time interaction effect on tendon stiffness was significant. Stiffness increased significantly for the long-duration protocol, but not for the short-duration protocol.The present study demonstrates a greater increase in stiffness of human tendon structures following isometric training using longer duration contractions compared to shorter contractions. This suggests that the changes in the elasticity of the tendon structures after resistance training may be affected by the duration of muscle contraction. PMID:11600697

  20. Alternative parallel ring protocols

    NASA Technical Reports Server (NTRS)

    Mukkamala, R.; Foudriat, E. C.; Maly, Kurt J.; Kale, V.

    1990-01-01

    Communication protocols are know to influence the utilization and performance of communication network. The effect of two token ring protocols on a gigabit network with multiple ring structure is investigated. In the first protocol, a mode sends at most one message on receiving a token. In the second protocol, a mode sends all the waiting messages when a token is received. The behavior of these protocols is shown to be highly dependent on the number of rings as well as the load in the network.

  1. Medical Images Remote Consultation

    NASA Astrophysics Data System (ADS)

    Ferraris, Maurizio; Frixione, Paolo; Squarcia, Sandro

    Teleconsultation of digital images among different medical centers is now a reality. The problem to be solved is how to interconnect all the clinical diagnostic devices in a hospital in order to allow physicians and health physicists, working in different places, to discuss on interesting clinical cases visualizing the same diagnostic images at the same time. Applying World Wide Web technologies, the proposed system can be easily used by people with no specific computer knowledge providing a verbose help to guide the user through the right steps of execution. Diagnostic images are retrieved from a relational database or from a standard DICOM-PACS through the DICOM-WWW gateway allowing connection of the usual Web browsers to DICOM applications via the HTTP protocol. The system, which is proposed for radiotherapy implementation, where radiographies play a fundamental role, can be easily converted to different field of medical applications where a remote access to secure data are compulsory.

  2. Cushing Syndrome: Diagnostic Workup and Imaging Features, With Clinical and Pathologic Correlation.

    PubMed

    Wagner-Bartak, Nicolaus A; Baiomy, Ali; Habra, Mouhammed Amir; Mukhi, Shalini V; Morani, Ajaykumar C; Korivi, Brinda R; Waguespack, Steven G; Elsayes, Khaled M

    2017-07-01

    Cushing syndrome (CS) is a constellation of clinical signs and symptoms resulting from chronic exposure to excess cortisol, either exogenous or endogenous. Exogenous CS is most commonly caused by administration of glucocorticoids. Endogenous CS is subdivided into two types: adrenocorticotropic hormone (ACTH) dependent and ACTH independent. Cushing disease, which is caused by a pituitary adenoma, is the most common cause of ACTH-dependent CS for which pituitary MRI can be diagnostic, with bilateral inferior petrosal sinus sampling useful in equivocal cases. In ectopic ACTH production, which is usually caused by a tumor in the thorax (e.g., small cell lung carcinoma, bronchial and thymic carcinoids, or medullary thyroid carcinoma) or abdomen (e.g., gastroenteropancreatic neuroendocrine tumors or pheochromocytoma), CT, MRI, and nuclear medicine tests are used for localizing the source of ACTH. In ACTH-independent CS, which is caused by various adrenal abnormalities, adrenal protocol CT or MRI is usually diagnostic.

  3. Errors in imaging patients in the emergency setting

    PubMed Central

    Reginelli, Alfonso; Lo Re, Giuseppe; Midiri, Federico; Muzj, Carlo; Romano, Luigia; Brunese, Luca

    2016-01-01

    Emergency and trauma care produces a “perfect storm” for radiological errors: uncooperative patients, inadequate histories, time-critical decisions, concurrent tasks and often junior personnel working after hours in busy emergency departments. The main cause of diagnostic errors in the emergency department is the failure to correctly interpret radiographs, and the majority of diagnoses missed on radiographs are fractures. Missed diagnoses potentially have important consequences for patients, clinicians and radiologists. Radiologists play a pivotal role in the diagnostic assessment of polytrauma patients and of patients with non-traumatic craniothoracoabdominal emergencies, and key elements to reduce errors in the emergency setting are knowledge, experience and the correct application of imaging protocols. This article aims to highlight the definition and classification of errors in radiology, the causes of errors in emergency radiology and the spectrum of diagnostic errors in radiography, ultrasonography and CT in the emergency setting. PMID:26838955

  4. Errors in imaging patients in the emergency setting.

    PubMed

    Pinto, Antonio; Reginelli, Alfonso; Pinto, Fabio; Lo Re, Giuseppe; Midiri, Federico; Muzj, Carlo; Romano, Luigia; Brunese, Luca

    2016-01-01

    Emergency and trauma care produces a "perfect storm" for radiological errors: uncooperative patients, inadequate histories, time-critical decisions, concurrent tasks and often junior personnel working after hours in busy emergency departments. The main cause of diagnostic errors in the emergency department is the failure to correctly interpret radiographs, and the majority of diagnoses missed on radiographs are fractures. Missed diagnoses potentially have important consequences for patients, clinicians and radiologists. Radiologists play a pivotal role in the diagnostic assessment of polytrauma patients and of patients with non-traumatic craniothoracoabdominal emergencies, and key elements to reduce errors in the emergency setting are knowledge, experience and the correct application of imaging protocols. This article aims to highlight the definition and classification of errors in radiology, the causes of errors in emergency radiology and the spectrum of diagnostic errors in radiography, ultrasonography and CT in the emergency setting.

  5. Prenatal diagnostic decision-making in adolescents.

    PubMed

    Plaga, Stacey L; Demarco, Kristin; Shulman, Lee P

    2005-04-01

    We sought to evaluate the prenatal decision-making of pregnant adolescents identified at increased risk for identifiable fetal genetic abnormalities. A retrospective review of records of gravid women 19 years old or younger undergoing genetic counseling from 2001-2003 (inclusive) was undertaken. Hospital-based academic center. Thirty-seven women were identified; four cases did not meet inclusion criteria. None. Decision to undergo or forgo invasive prenatal testing. Of the 33 women included in this study, the average age was 17.6 years (range: 15-19). Eighteen were Latinas, eight were African-Americans, and seven were Caucasians. Sixteen women had positive maternal serum screening outcomes; nine women sought counseling because of personal/family histories of genetic abnormalities, seven sought counseling after fetal structural anomalies were detected by ultrasound, and one woman sought counseling because she and her partner were positive for Mendelian disorder screening (sickle cell disease). Sixteen of the women (48.5%) chose to undergo invasive testing (15 amniocenteses, one chorionic villus sampling) whereas 17 (51.5%) chose to forgo invasive testing. Adolescents offered invasive prenatal diagnosis will chose to undergo or forgo such testing based on diagnostic and personal criteria as do adult women. Nonetheless, unique adolescent issues may make the process by which information is obtained and communicated during counseling to be different from counseling provided to adults. The development of new genetic screening and diagnostic protocols has and will increase the number of pregnant adolescent women who will be offered genetic counseling during their pregnancies. Such an increase in numbers will place considerably more pressure on an already taxed genetic counseling system; accordingly, new counseling paradigms will need to be developed to provide service to an expanded patient population seeking information for an increasing number of genetic issues.

  6. Heterocyclic Scaffolds for the Treatment of Alzheimer's Disease.

    PubMed

    Martorana, Annamaria; Giacalone, Valentina; Bonsignore, Riccardo; Pace, Andrea; Gentile, Carla; Pibiri, Ivana; Buscemi, Silvestre; Lauria, Antonino; Piccionello, Antonio Palumbo

    2016-01-01

    The treatment and diagnosis of Alzheimer's Disease (AD) are two of the most urgent goals for research around the world. The cognitive decline is generally associated with the elevated levels of extracellular senile plaques, intracellular neurofibrillary tangles (NFTs), and with a progressive shutdown of the cholinergic basal forebrain neurons transmission. Even if several key targets are under fervent investigation in the cure of AD, till now, the only approved therapeutic strategy is the treatment of symptoms by using cholinesterases inhibitors. It has been demonstrated that both acetylcholinesterase (AChE) and butyrylcholinesterase (BuChE) enzymes are not only responsible of acetylcholine levels, but also play an pivotal role in Aβ-aggregation during the early stages of senile plaque formation. On the other hand the difficult management of AD is also related to effective diagnostic methods and efficient assays for the study of pathological features. In such complex a wide framework, heterocyclic molecules are essential backbone to build new and selective drugs as well as diagnostic probes. The goal of this review is to examine a selected sample of relevant applications of five- and six-membered heterocycles in AD's therapeutic approaches. Concerning the research on AD, the contribution of heterocyclic compounds is huge and here we report some representative examples. The review is organized in two main sections focused on five and six-membered heterocycles. The analyzed cases have been classified on the base of the structural features of molecules, taking into account the progressive increase in heteroatoms number. The discovery of an effective therapy or a diagnostic protocol for AD is still far, but consistent improvements are underway and contribution of heterocyclic compounds will be consistent and hopefully determinant.

  7. Microfluidic Platform for Parallel Single Cell Analysis for Diagnostic Applications.

    PubMed

    Le Gac, Séverine

    2017-01-01

    Cell populations are heterogeneous: they can comprise different cell types or even cells at different stages of the cell cycle and/or of biological processes. Furthermore, molecular processes taking place in cells are stochastic in nature. Therefore, cellular analysis must be brought down to the single cell level to get useful insight into biological processes, and to access essential molecular information that would be lost when using a cell population analysis approach. Furthermore, to fully characterize a cell population, ideally, information both at the single cell level and on the whole cell population is required, which calls for analyzing each individual cell in a population in a parallel manner. This single cell level analysis approach is particularly important for diagnostic applications to unravel molecular perturbations at the onset of a disease, to identify biomarkers, and for personalized medicine, not only because of the heterogeneity of the cell sample, but also due to the availability of a reduced amount of cells, or even unique cells. This chapter presents a versatile platform meant for the parallel analysis of individual cells, with a particular focus on diagnostic applications and the analysis of cancer cells. We first describe one essential step of this parallel single cell analysis protocol, which is the trapping of individual cells in dedicated structures. Following this, we report different steps of a whole analytical process, including on-chip cell staining and imaging, cell membrane permeabilization and/or lysis using either chemical or physical means, and retrieval of the cell molecular content in dedicated channels for further analysis. This series of experiments illustrates the versatility of the herein-presented platform and its suitability for various analysis schemes and different analytical purposes.

  8. Technological challenges in Magnetic Resonance Imaging: enhancing sensitivity, moving to quantitative imaging and searching for disease biomarkers

    NASA Astrophysics Data System (ADS)

    Retico, A.

    2018-02-01

    Diagnostic imaging based on the Nuclear Magnetic Resonance phenomenon has increasingly spread in the recent few decades, mainly owing to its exquisite capability in depicting a contrast between soft tissues, to its generally non-invasive nature, and to the priceless advantage of using non-ionizing radiation. Magnetic Resonance (MR)-based acquisition techniques allow gathering information on the structure (through Magnetic Resonance Imaging— MRI), the metabolic composition (through Magnetic Resonance Spectroscopy—MRS), and the functioning (through functional MRI —fMRI) of the human body. MR investigations are the methods of choice for studying the brain in vivo, including anatomy, structural wiring and functional connectivity, in healthy and pathological conditions. Alongside the efforts of the clinical research community in extending the acquisition protocols to allow the exploration of a large variety of pathologies affecting diverse body regions, some relevant technological improvements are on the way to maximize the impact of MR in medical diagnostic. The development of MR scanners operating at ultra-high magnetic field (UHF) strength (>= 7 tesla), is pushing forward the spatial resolution of MRI and the spectral resolution of MRS, and it is increasing the specificity of fMRI to grey matter signal. UHF MR systems are currently in use for research purposes only; nevertheless, UHF technological advances are positively affecting MR investigations at clinical field strengths. To overcome the current major limitation of MRI, which is mostly based on contrast between tissues rather than on absolute measurements of physical quantities, a new acquisition modality is under development, which is referred as Magnetic Resonance Fingerprinting technique. Finally, as neuroimaging data acquired worldwide are reaching the typical size of Big Data, dedicated technical solutions are required to mine large amount of information and to identify specific biomarkers of pathological conditions.

  9. Thick SS316 materials TIG welding development activities towards advanced fusion reactor vacuum vessel applications

    NASA Astrophysics Data System (ADS)

    Kumar, B. Ramesh; Gangradey, R.

    2012-11-01

    Advanced fusion reactors like ITER and up coming Indian DEMO devices are having challenges in terms of their materials design and fabrication procedures. The operation of these devices is having various loads like structural, thermo-mechanical and neutron irradiation effects on major systems like vacuum vessel, divertor, magnets and blanket modules. The concept of double wall vacuum vessel (VV) is proposed in view of protecting of major reactor subsystems like super conducting magnets, diagnostic systems and other critical components from high energy 14 MeV neutrons generated from fusion plasma produced by D-T reactions. The double walled vacuum vessel is used in combination with pressurized water circulation and some special grade borated steel blocks to shield these high energy neutrons effectively. The fabrication of sub components in VV are mainly used with high thickness SS materials in range of 20 mm- 60 mm of various grades based on the required protocols. The structural components of double wall vacuum vessel uses various parts like shields, ribs, shells and diagnostic vacuum ports. These components are to be developed with various welding techniques like TIG welding, Narrow gap TIG welding, Laser welding, Hybrid TIG laser welding, Electron beam welding based on requirement. In the present paper the samples of 20 mm and 40 mm thick SS 316 materials are developed with TIG welding process and their mechanical properties characterization with Tensile, Bend tests and Impact tests are carried out. In addition Vickers hardness tests and microstructural properties of Base metal, Heat Affected Zone (HAZ) and Weld Zone are done. TIG welding application with high thick SS materials in connection with vacuum vessel requirements and involved criticalities towards welding process are highlighted.

  10. Zoom Reconstruction Tool: Evaluation of Image Quality and Influence on the Diagnosis of Root Fracture.

    PubMed

    Queiroz, Polyane Mazucatto; Santaella, Gustavo Machado; Capelozza, Ana Lúcia Alvares; Rosalen, Pedro Luiz; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2018-04-01

    This study evaluated the image quality and the diagnosis of root fractures when using the Zoom Reconstruction tool (J Morita, Kyoto, Japan). A utility wax phantom with a metal sample inside was used for objective evaluation, and a mandible with 27 single-rooted teeth (with and without obturation and with and without vertical or horizontal fractures) was used for diagnostic evaluation. The images were acquired in 3 protocols: protocol 1, field of view (FOV) of 4 × 4 cm and a voxel size of 0.08 mm; protocol 2, FOV of 10 × 10 cm and a voxel size of 0.2 mm; and protocol 3, Zoom Reconstruction of images from protocol 2 (FOV of 4 × 4 cm and a voxel size of 0.08 mm). The objective evaluation was achieved by measuring the image noise, and the diagnosis of fractures was performed by 3 evaluators. The area under the receiver operating characteristic curve was used to calculate accuracy, and analysis of variance compared the accuracy and image quality of the protocols. Regarding quality, protocol 1 was superior to protocol 2 (P < .0001) and Zoom Reconstruction (P < .0001). Additionally, images of protocol 2 presented less noise than the Zoom Reconstruction image (P < .0001); however, for diagnosis, Zoom Reconstruction was superior in relation to protocol 2 (P = .011) and did not differ from protocol 1 (P = .228) for the diagnosis of a vertical root fracture in filled teeth. The Zoom Reconstruction tool allows better accuracy for vertical root fracture detection in filled teeth, making it possible to obtain a higher-resolution image from a lower-resolution examination without having to expose the patient to more radiation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Imaging and radiology

    MedlinePlus

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  12. Using semantics for representing experimental protocols.

    PubMed

    Giraldo, Olga; García, Alexander; López, Federico; Corcho, Oscar

    2017-11-13

    An experimental protocol is a sequence of tasks and operations executed to perform experimental research in biological and biomedical areas, e.g. biology, genetics, immunology, neurosciences, virology. Protocols often include references to equipment, reagents, descriptions of critical steps, troubleshooting and tips, as well as any other information that researchers deem important for facilitating the reusability of the protocol. Although experimental protocols are central to reproducibility, the descriptions are often cursory. There is the need for a unified framework with respect to the syntactic structure and the semantics for representing experimental protocols. In this paper we present "SMART Protocols ontology", an ontology for representing experimental protocols. Our ontology represents the protocol as a workflow with domain specific knowledge embedded within a document. We also present the S ample I nstrument R eagent O bjective (SIRO) model, which represents the minimal common information shared across experimental protocols. SIRO was conceived in the same realm as the Patient Intervention Comparison Outcome (PICO) model that supports search, retrieval and classification purposes in evidence based medicine. We evaluate our approach against a set of competency questions modeled as SPARQL queries and processed against a set of published and unpublished protocols modeled with the SP Ontology and the SIRO model. Our approach makes it possible to answer queries such as Which protocols use tumor tissue as a sample. Improving reporting structures for experimental protocols requires collective efforts from authors, peer reviewers, editors and funding bodies. The SP Ontology is a contribution towards this goal. We build upon previous experiences and bringing together the view of researchers managing protocols in their laboratory work. Website: https://smartprotocols.github.io/ .

  13. Low-cost Cognitive Electronics Technology for Enhanced Communications and Situational Awareness for Networks of Small Unmanned Aerial Vehicles (UAV)

    DTIC Science & Technology

    2013-03-01

    series of checkpoints in a complex route network,” while observing standard traffic etiquette and regulations [17]. The rules for the 2012 RoboCup...structure or protocols above the PHY. To support AVEP operation, we developed a packet structure based on the transmission control protocol (TCP...Control Protocol .” 1981. [37] F. Ge, Q. Chen, Y. Wang, C. W. Bostian, T. W. Rondeau, and B. Le, “Cognitive radio: from spectrum sharing to adaptive

  14. Complete radiotherapy response in rectal cancer: A review of the evidence

    PubMed Central

    Couch, Daniel G; Hemingway, David M

    2016-01-01

    Complete response to chemoradiotherapy for rectal cancer is becoming a common clinical entity. Techniques to diagnose complete response and how to survey these patients without operative intervention are still unclear. We review the most recent evidence. Barriers to firm conclusions regarding this are heterogeneity of diagnostic definitions, differing surveillance protocols, and a lack of randomised studies. PMID:26811600

  15. 9 CFR 82.2 - Criteria for determining birds or poultry to be infected with, exposed to, or free from END.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of the following factors: clinical evidence (signs, post-mortem lesions, and history of the..., Animal and Plant Health Inspection Service, 4700 River Road, Unit 41, Riverdale, MD 20737-1231, or by... Road Unit 41, Riverdale, MD 20737-1231. The protocols are also found in “Recommended Uniform Diagnostic...

  16. 9 CFR 82.2 - Criteria for determining birds or poultry to be infected with, exposed to, or free from END.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of the following factors: clinical evidence (signs, post-mortem lesions, and history of the..., Animal and Plant Health Inspection Service, 4700 River Road, Unit 41, Riverdale, MD 20737-1231, or by... Road Unit 41, Riverdale, MD 20737-1231. The protocols are also found in “Recommended Uniform Diagnostic...

  17. Lyman C. Johnston, DC, FICC, FCCS(C): Canadian chiropractic's postural research pioneer and inventive entrepreneur

    PubMed Central

    Brown, Douglas M.

    2001-01-01

    This paper profiles Dr. Lyman Johnston and his contributions in the field of chiropractic research. Postural concepts, diagnostic instruments, therapeutic devices and treatment protocols are reviewed. Set out and briefly discussed are the Posturometer, Pyramidal Man, anterior-posterior gravity line, Postural Spinal Index, tension master, Spine Power Belt and the Mini-Gym. ImagesFigure 1

  18. 9 CFR 82.2 - Criteria for determining birds or poultry to be infected with, exposed to, or free from END.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... veterinarians and State veterinarians may be obtained by writing to Emergency Programs, Veterinary Services... referring to the local telephone book. 2 A copy of the protocols for END diagnostic tests may be obtained by writing to Emergency Programs, Veterinary Services, Animal and Plant Health Inspection Service, 4700 River...

  19. [PET/CT: protocol aspects and legal controversies].

    PubMed

    Gorospe Sarasúa, L; Vicente Bártulos, A; González Gordaliza, C; García Poza, J; Lourido García, D; Jover Díaz, R

    2008-01-01

    The combination of positron emission tomography (PET) and computed tomography (CT) in a single scanner (PET/CT) allows anatomic and metabolic images to be fused and correlated with a high degree of accuracy; this represents a very important landmark in the history of medicine and especially in the area of diagnostic imaging. Nevertheless, the implementation, startup, and operation of a PET/CT scanner presents particularly interesting challenges, because it involves the integration of two well-established and consolidated techniques (CT and PET, which provide complementary information) that have traditionally been carried out in the context of two different specialties (radiology and nuclear medicine). The rapid diffusion of this new integrated technology raises a series of questions related to the optimal protocols for image acquisition, the supervision of the examinations, image interpretation, and reporting, as well as questions related to the legal competence and responsibility of the specialists involved in a PET/CT study. The objective of this article is to approach these aspects from a constructive perspective and to stimulate the dialog between the specialties of radiology and nuclear medicine, with the aim of maximizing the diagnostic potential of PET/CT and thus of providing better care for patients.

  20. Fluorescent labeling of NASBA amplified tmRNA molecules for microarray applications

    PubMed Central

    Scheler, Ott; Glynn, Barry; Parkel, Sven; Palta, Priit; Toome, Kadri; Kaplinski, Lauris; Remm, Maido; Maher, Majella; Kurg, Ants

    2009-01-01

    Background Here we present a novel promising microbial diagnostic method that combines the sensitivity of Nucleic Acid Sequence Based Amplification (NASBA) with the high information content of microarray technology for the detection of bacterial tmRNA molecules. The NASBA protocol was modified to include aminoallyl-UTP (aaUTP) molecules that were incorporated into nascent RNA during the NASBA reaction. Post-amplification labeling with fluorescent dye was carried out subsequently and tmRNA hybridization signal intensities were measured using microarray technology. Significant optimization of the labeled NASBA protocol was required to maintain the required sensitivity of the reactions. Results Two different aaUTP salts were evaluated and optimum final concentrations were identified for both. The final 2 mM concentration of aaUTP Li-salt in NASBA reaction resulted in highest microarray signals overall, being twice as high as the strongest signals with 1 mM aaUTP Na-salt. Conclusion We have successfully demonstrated efficient combination of NASBA amplification technology with microarray based hybridization detection. The method is applicative for many different areas of microbial diagnostics including environmental monitoring, bio threat detection, industrial process monitoring and clinical microbiology. PMID:19445684

  1. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  2. Guidelines and sample protocol for sampling forest gaps.

    Treesearch

    J.R. Runkle

    1992-01-01

    A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.

  3. Examining a New Method to Studying Velopharyngeal Structures in a Child With 22q11.2 Deletion Syndrome.

    PubMed

    Kollara, Lakshmi; Schenck, Graham; Jaskolka, Michael; Perry, Jamie L

    2017-04-14

    To date, no studies have imaged the velopharynx in children with 22q11.2 deletion syndrome (22q11.2 DS) without the use of sedation. Dysmorphology in velopharyngeal structures has been shown to have significant negative implications on speech among these individuals. This single case study was designed to assess the feasibility of a child-friendly magnetic resonance imaging (MRI) scanning protocol in this clinically challenging population and to determine the utility of this MRI protocol for future work in this area. One 6-year-old White girl diagnosed with 22q11.2 DS was imaged using a child-friendly, nonsedated MRI protocol. Quantitative and qualitative measures of the velopharyngeal area and associated structures were evaluated, and comparisons were made to age-matched control subjects with normal velopharyngeal anatomy. MRI data were successfully obtained using the child-friendly scanning protocol in the subject in the present study. Quantitative and qualitative differences of the levator muscle and associated velopharyngeal structures were noted. Using these MRI and structural analyses methods, insights related to muscle morphology can be obtained and considered as part of the research and clinical examination of children with 22q11.2 DS. The imaging protocol described in this study presents an effective means to counteract difficulties in imaging young children.

  4. A statistical approach to detection of copy number variations in PCR-enriched targeted sequencing data.

    PubMed

    Demidov, German; Simakova, Tamara; Vnuchkova, Julia; Bragin, Anton

    2016-10-22

    Multiplex polymerase chain reaction (PCR) is a common enrichment technique for targeted massive parallel sequencing (MPS) protocols. MPS is widely used in biomedical research and clinical diagnostics as the fast and accurate tool for the detection of short genetic variations. However, identification of larger variations such as structure variants and copy number variations (CNV) is still being a challenge for targeted MPS. Some approaches and tools for structural variants detection were proposed, but they have limitations and often require datasets of certain type, size and expected number of amplicons affected by CNVs. In the paper, we describe novel algorithm for high-resolution germinal CNV detection in the PCR-enriched targeted sequencing data and present accompanying tool. We have developed a machine learning algorithm for the detection of large duplications and deletions in the targeted sequencing data generated with PCR-based enrichment step. We have performed verification studies and established the algorithm's sensitivity and specificity. We have compared developed tool with other available methods applicable for the described data and revealed its higher performance. We showed that our method has high specificity and sensitivity for high-resolution copy number detection in targeted sequencing data using large cohort of samples.

  5. Interfacing the PACS and the HIS: results of a 5-year implementation.

    PubMed

    Kinsey, T V; Horton, M C; Lewis, T E

    2000-01-01

    An interface was created between the Department of Defense's hospital information system (HIS) and its two picture archiving and communication system (PACS)-based radiology information systems (RISs). The HIS is called the Composite Healthcare Computer System (CHCS), and the RISs are called the Medical Diagnostic Imaging System (MDIS) and the Digital Imaging Network (DIN)-PACS. Extensive mapping between dissimilar data protocols was required to translate data from the HIS into both RISs. The CHCS uses a Health Level 7 (HL7) protocol, whereas the MDIS uses the American College of Radiology-National Electrical Manufacturers Association 2.0 protocol and the DIN-PACS uses the Digital Imaging and Communications in Medicine (DICOM) 3.0 protocol. An interface engine was required to change some data formats, as well as to address some nonstandard HL7 data being output from the CHCS. In addition, there are differences in terminology between fields and segments in all three protocols. This interface is in use at 20 military facilities throughout the world. The interface reduces the amount of manual entry into more than one automated system to the smallest level possible. Data mapping during installation saved time, improved productivity, and increased user acceptance during PACS implementation. It also resulted in more standardized database entries in both the HIS (CHCS) and the RIS (PACS).

  6. Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

    PubMed

    Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H

    2017-07-01

    The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.

  7. SMART Layer and SMART Suitcase for structural health monitoring applications

    NASA Astrophysics Data System (ADS)

    Lin, Mark; Qing, Xinlin; Kumar, Amrita; Beard, Shawn J.

    2001-06-01

    Knowledge of integrity of in-service structures can greatly enhance their safety and reliability and lower structural maintenance cost. Current practices limit the extent of real-time knowledge that can be obtained from structures during inspection, are labor-intensive and thereby increase life-cycle costs. Utilization of distributed sensors integrated with the structure is a viable and cost-effective means of monitoring the structure and reducing inspection costs. Acellent Technologies is developing a novel system for actively and passively interrogating the health of a structure through an integrated network of sensors and actuators. Acellent's system comprises of SMART Layers, SMART Suitcase and diagnostic software. The patented SMART Layer is a thin dielectric film with an embedded network of distributed piezoelectric actuators/sensors that can be surface-mounted on metallic structures or embedded inside composite structures. The SMART Suitcase is a portable diagnostic unit designed with multiple sensor/actuator channels to interface with the SMART Layer, generate diagnostic signals from actuators and record measurements from the embedded sensors. With appropriate diagnostic software, Acellent's system can be used for monitoring structural condition and for detecting damage while the structures are in service. This paper enumerates on the SMART Layer and SMART Suitcase and their applicability to composite and metal structures.

  8. How do gut feelings feature in tutorial dialogues on diagnostic reasoning in GP traineeship?

    PubMed

    Stolper, C F; Van de Wiel, M W J; Hendriks, R H M; Van Royen, P; Van Bokhoven, M A; Van der Weijden, T; Dinant, G J

    2015-05-01

    Diagnostic reasoning is considered to be based on the interaction between analytical and non-analytical cognitive processes. Gut feelings, a specific form of non-analytical reasoning, play a substantial role in diagnostic reasoning by general practitioners (GPs) and may activate analytical reasoning. In GP traineeships in the Netherlands, trainees mostly see patients alone but regularly consult with their supervisors to discuss patients and problems, receive feedback, and improve their competencies. In the present study, we examined the discussions of supervisors and their trainees about diagnostic reasoning in these so-called tutorial dialogues and how gut feelings feature in these discussions. 17 tutorial dialogues focussing on diagnostic reasoning were video-recorded and transcribed and the protocols were analysed using a detailed bottom-up and iterative content analysis and coding procedure. The dialogues were segmented into quotes. Each quote received a content code and a participant code. The number of words per code was used as a unit of analysis to quantitatively compare the contributions to the dialogues made by supervisors and trainees, and the attention given to different topics. The dialogues were usually analytical reflections on a trainee's diagnostic reasoning. A hypothetico-deductive strategy was often used, by listing differential diagnoses and discussing what information guided the reasoning process and might confirm or exclude provisional hypotheses. Gut feelings were discussed in seven dialogues. They were used as a tool in diagnostic reasoning, inducing analytical reflection, sometimes on the entire diagnostic reasoning process. The emphasis in these tutorial dialogues was on analytical components of diagnostic reasoning. Discussing gut feelings in tutorial dialogues seems to be a good educational method to familiarize trainees with non-analytical reasoning. Supervisors need specialised knowledge about these aspects of diagnostic reasoning and how to deal with them in medical education.

  9. New Diagnostic and Therapeutic Approaches for Preventing the Progression of Diabetic Retinopathy

    PubMed Central

    Park, Young Gun; Roh, Young-Jung

    2016-01-01

    Diabetic retinopathy (DR) is a severe sight-threatening complication of diabetes mellitus. Retinal laser photocoagulation, antivascular endothelial growth factors, steroid therapy, and pars plana vitrectomy are now used extensively to treat advanced stages of diabetic retinopathy. Currently, diagnostic devices like ultrawide field fundus fluorescein angiography and the improvement of optical coherence tomography have provided quicker and more precise diagnosis of early diabetic retinopathy. Thus, treatment protocols have been modified accordingly. Various types of lasers, including the subthreshold micropulse laser and RPE-targeting laser, and selective targeted photocoagulation may be future alternatives to conventional retinal photocoagulation, with fewer complications. The new developed intravitreal medications and implants have provided more therapeutic options, with promising results. PMID:26881240

  10. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2017-05-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The diagnosis of urinary tract infections in young children (DUTY): protocol for a diagnostic and prospective observational study to derive and validate a clinical algorithm for the diagnosis of UTI in children presenting to primary care with an acute illness.

    PubMed

    Downing, Harriet; Thomas-Jones, Emma; Gal, Micaela; Waldron, Cherry-Ann; Sterne, Jonathan; Hollingworth, William; Hood, Kerenza; Delaney, Brendan; Little, Paul; Howe, Robin; Wootton, Mandy; Macgowan, Alastair; Butler, Christopher C; Hay, Alastair D

    2012-07-19

    Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted.The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens.We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children.

  13. The diagnosis of urinary tract infections in young children (DUTY): protocol for a diagnostic and prospective observational study to derive and validate a clinical algorithm for the diagnosis of UTI in children presenting to primary care with an acute illness

    PubMed Central

    2012-01-01

    Background Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. Methods/design DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted. The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens. We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. Discussion This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children. PMID:22812651

  14. Lessons learned from additional research analyses of unsolved clinical exome cases.

    PubMed

    Eldomery, Mohammad K; Coban-Akdemir, Zeynep; Harel, Tamar; Rosenfeld, Jill A; Gambin, Tomasz; Stray-Pedersen, Asbjørg; Küry, Sébastien; Mercier, Sandra; Lessel, Davor; Denecke, Jonas; Wiszniewski, Wojciech; Penney, Samantha; Liu, Pengfei; Bi, Weimin; Lalani, Seema R; Schaaf, Christian P; Wangler, Michael F; Bacino, Carlos A; Lewis, Richard Alan; Potocki, Lorraine; Graham, Brett H; Belmont, John W; Scaglia, Fernando; Orange, Jordan S; Jhangiani, Shalini N; Chiang, Theodore; Doddapaneni, Harsha; Hu, Jianhong; Muzny, Donna M; Xia, Fan; Beaudet, Arthur L; Boerwinkle, Eric; Eng, Christine M; Plon, Sharon E; Sutton, V Reid; Gibbs, Richard A; Posey, Jennifer E; Yang, Yaping; Lupski, James R

    2017-03-21

    Given the rarity of most single-gene Mendelian disorders, concerted efforts of data exchange between clinical and scientific communities are critical to optimize molecular diagnosis and novel disease gene discovery. We designed and implemented protocols for the study of cases for which a plausible molecular diagnosis was not achieved in a clinical genomics diagnostic laboratory (i.e. unsolved clinical exomes). Such cases were recruited to a research laboratory for further analyses, in order to potentially: (1) accelerate novel disease gene discovery; (2) increase the molecular diagnostic yield of whole exome sequencing (WES); and (3) gain insight into the genetic mechanisms of disease. Pilot project data included 74 families, consisting mostly of parent-offspring trios. Analyses performed on a research basis employed both WES from additional family members and complementary bioinformatics approaches and protocols. Analysis of all possible modes of Mendelian inheritance, focusing on both single nucleotide variants (SNV) and copy number variant (CNV) alleles, yielded a likely contributory variant in 36% (27/74) of cases. If one includes candidate genes with variants identified within a single family, a potential contributory variant was identified in a total of ~51% (38/74) of cases enrolled in this pilot study. The molecular diagnosis was achieved in 30/63 trios (47.6%). Besides this, the analysis workflow yielded evidence for pathogenic variants in disease-associated genes in 4/6 singleton cases (66.6%), 1/1 multiplex family involving three affected siblings, and 3/4 (75%) quartet families. Both the analytical pipeline and the collaborative efforts between the diagnostic and research laboratories provided insights that allowed recent disease gene discoveries (PURA, TANGO2, EMC1, GNB5, ATAD3A, and MIPEP) and increased the number of novel genes, defined in this study as genes identified in more than one family (DHX30 and EBF3). An efficient genomics pipeline in which clinical sequencing in a diagnostic laboratory is followed by the detailed reanalysis of unsolved cases in a research environment, supplemented with WES data from additional family members, and subject to adjuvant bioinformatics analyses including relaxed variant filtering parameters in informatics pipelines, can enhance the molecular diagnostic yield and provide mechanistic insights into Mendelian disorders. Implementing these approaches requires collaborative clinical molecular diagnostic and research efforts.

  15. Rapid One-step Enzymatic Synthesis and All-aqueous Purification of Trehalose Analogues.

    PubMed

    Meints, Lisa M; Poston, Anne W; Piligian, Brent F; Olson, Claire D; Badger, Katherine S; Woodruff, Peter J; Swarts, Benjamin M

    2017-02-17

    Chemically modified versions of trehalose, or trehalose analogues, have applications in biology, biotechnology, and pharmaceutical science, among other fields. For instance, trehalose analogues bearing detectable tags have been used to detect Mycobacterium tuberculosis and may have applications as tuberculosis diagnostic imaging agents. Hydrolytically stable versions of trehalose are also being pursued due to their potential for use as non-caloric sweeteners and bioprotective agents. Despite the appeal of this class of compounds for various applications, their potential remains unfulfilled due to the lack of a robust route for their production. Here, we report a detailed protocol for the rapid and efficient one-step biocatalytic synthesis of trehalose analogues that bypasses the problems associated with chemical synthesis. By utilizing the thermostable trehalose synthase (TreT) enzyme from Thermoproteus tenax, trehalose analogues can be generated in a single step from glucose analogues and uridine diphosphate glucose in high yield (up to quantitative conversion) in 15-60 min. A simple and rapid non-chromatographic purification protocol, which consists of spin dialysis and ion exchange, can deliver many trehalose analogues of known concentration in aqueous solution in as little as 45 min. In cases where unreacted glucose analogue still remains, chromatographic purification of the trehalose analogue product can be performed. Overall, this method provides a "green" biocatalytic platform for the expedited synthesis and purification of trehalose analogues that is efficient and accessible to non-chemists. To exemplify the applicability of this method, we describe a protocol for the synthesis, all-aqueous purification, and administration of a trehalose-based click chemistry probe to mycobacteria, all of which took less than 1 hour and enabled fluorescence detection of mycobacteria. In the future, we envision that, among other applications, this protocol may be applied to the rapid synthesis of trehalose-based probes for tuberculosis diagnostics. For instance, short-lived radionuclide-modified trehalose analogues (e.g., 18 F-modified trehalose) could be used for advanced clinical imaging modalities such as positron emission tomography-computed tomography (PET-CT).

  16. Brain Gliomas: Multicenter Standardized Assessment of Dynamic Contrast-enhanced and Dynamic Susceptibility Contrast MR Images.

    PubMed

    Anzalone, Nicoletta; Castellano, Antonella; Cadioli, Marcello; Conte, Gian Marco; Cuccarini, Valeria; Bizzi, Alberto; Grimaldi, Marco; Costa, Antonella; Grillea, Giovanni; Vitali, Paolo; Aquino, Domenico; Terreni, Maria Rosa; Torri, Valter; Erickson, Bradley J; Caulo, Massimo

    2018-06-01

    Purpose To evaluate the feasibility of a standardized protocol for acquisition and analysis of dynamic contrast material-enhanced (DCE) and dynamic susceptibility contrast (DSC) magnetic resonance (MR) imaging in a multicenter clinical setting and to verify its accuracy in predicting glioma grade according to the new World Health Organization 2016 classification. Materials and Methods The local research ethics committees of all centers approved the study, and informed consent was obtained from patients. One hundred patients with glioma were prospectively examined at 3.0 T in seven centers that performed the same preoperative MR imaging protocol, including DCE and DSC sequences. Two independent readers identified the perfusion hotspots on maps of volume transfer constant (K trans ), plasma (v p ) and extravascular-extracellular space (v e ) volumes, initial area under the concentration curve, and relative cerebral blood volume (rCBV). Differences in parameters between grades and molecular subtypes were assessed by using Kruskal-Wallis and Mann-Whitney U tests. Diagnostic accuracy was evaluated by using receiver operating characteristic curve analysis. Results The whole protocol was tolerated in all patients. Perfusion maps were successfully obtained in 94 patients. An excellent interreader reproducibility of DSC- and DCE-derived measures was found. Among DCE-derived parameters, v p and v e had the highest accuracy (are under the receiver operating characteristic curve [A z ] = 0.847 and 0.853) for glioma grading. DSC-derived rCBV had the highest accuracy (A z = 0.894), but the difference was not statistically significant (P > .05). Among lower-grade gliomas, a moderate increase in both v p and rCBV was evident in isocitrate dehydrogenase wild-type tumors, although this was not significant (P > .05). Conclusion A standardized multicenter acquisition and analysis protocol of DCE and DSC MR imaging is feasible and highly reproducible. Both techniques showed a comparable, high diagnostic accuracy for grading gliomas. © RSNA, 2018 Online supplemental material is available for this article.

  17. Low contrast media volume in pre-TAVI CT examinations.

    PubMed

    Kok, Madeleine; Turek, Jakub; Mihl, Casper; Reinartz, Sebastian D; Gohmann, Robin F; Nijssen, Estelle C; Kats, Suzanne; van Ommen, Vincent G; Kietselaer, Bas L J H; Wildberger, Joachim E; Das, Marco

    2016-08-01

    To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. • Image quality could be maintained using low kVp scan protocols. • Low kVp protocols reduce contrast media volume by 34-67 %. • Less contrast media volume lowers the risk of contrast-induced nephropathy.

  18. Hierarchical mixture of experts and diagnostic modeling approach to reduce hydrologic model structural uncertainty: STRUCTURAL UNCERTAINTY DIAGNOSTICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moges, Edom; Demissie, Yonas; Li, Hong-Yi

    2016-04-01

    In most water resources applications, a single model structure might be inadequate to capture the dynamic multi-scale interactions among different hydrological processes. Calibrating single models for dynamic catchments, where multiple dominant processes exist, can result in displacement of errors from structure to parameters, which in turn leads to over-correction and biased predictions. An alternative to a single model structure is to develop local expert structures that are effective in representing the dominant components of the hydrologic process and adaptively integrate them based on an indicator variable. In this study, the Hierarchical Mixture of Experts (HME) framework is applied to integratemore » expert model structures representing the different components of the hydrologic process. Various signature diagnostic analyses are used to assess the presence of multiple dominant processes and the adequacy of a single model, as well as to identify the structures of the expert models. The approaches are applied for two distinct catchments, the Guadalupe River (Texas) and the French Broad River (North Carolina) from the Model Parameter Estimation Experiment (MOPEX), using different structures of the HBV model. The results show that the HME approach has a better performance over the single model for the Guadalupe catchment, where multiple dominant processes are witnessed through diagnostic measures. Whereas, the diagnostics and aggregated performance measures prove that French Broad has a homogeneous catchment response, making the single model adequate to capture the response.« less

  19. When the bell tolls on Bell's palsy: finding occult malignancy in acute-onset facial paralysis.

    PubMed

    Quesnel, Alicia M; Lindsay, Robin W; Hadlock, Tessa A

    2010-01-01

    This study reports 4 cases of occult parotid malignancy presenting with sudden-onset facial paralysis to demonstrate that failure to regain tone 6 months after onset distinguishes these patients from Bell's palsy patients with delayed recovery and to propose a diagnostic algorithm for this subset of patients. A case series of 4 patients with occult parotid malignancies presenting with acute-onset unilateral facial paralysis is reported. Initial imaging on all 4 patients did not demonstrate a parotid mass. Diagnostic delays ranged from 7 to 36 months from time of onset of facial paralysis to time of diagnosis of parotid malignancy. Additional physical examination findings, especially failure to regain tone, as well as properly protocolled radiologic studies reviewed with dedicated head and neck radiologists, were helpful in arriving at the diagnosis. An algorithm to minimize diagnostic delays in this subset of acute facial paralysis patients is presented. Careful attention to facial tone, in addition to movement, is important in the diagnostic evaluation of acute-onset facial paralysis. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Adulticidal Susceptibility Evaluation of Aedes albopictus Using New Diagnostic Doses in Penang Island, Malaysia.

    PubMed

    Rahim, Junaid; Ahmad, Abu H; Ahmad, Hamdan; Ishak, Intan H; Rus, Adanan Che; Maimusa, Hamisu A

    2017-09-01

    Insecticide-based vector control approaches are facing challenges due to the development of resistance in vector mosquitoes. Therefore, a proper resistance surveillance program using baseline lethal concentrations is crucial for resistance management strategies. Currently, the World Health Organization's (WHO) diagnostic doses established for Aedes aegypti and Anopheles species are being used to study the resistance status of Aedes albopictus. In this study, we established the diagnostic doses for permethrin, deltamethrin, and malathion using a known susceptible reference strain. Five field-collected populations were screened against these doses, following the WHO protocol. This study established the diagnostic dose of malathion at 2.4%, permethrin at 0.95%, and deltamethrin at 0.28%, which differ from the WHO doses for Aedes aegypti and Anopheles spp. Among the insecticides tested on the 5 wild populations, only deltamethrin showed high effectiveness. Different susceptibility and resistance patterns were observed with permethrin, malathion, and dichloro-diphenyl-trichloroethane (DDT) at 4%. This study may assist the health authorities to improve future chemical-based vector control operations in dengue-endemic areas.

  1. Vascular dementia: Diagnostic criteria and supplementary exams. Recommendations of the Scientific Department of Cognitive Neurology and Aging of the Brazilian Academy of Neurology. Part I

    PubMed Central

    Engelhardt, Eliasz; Tocquer, Carla; André, Charles; Moreira, Denise Madeira; Okamoto, Ivan Hideyo; Cavalcanti, José Luiz de Sá

    2011-01-01

    Vascular dementia (VaD) is the most prevalent form of secondary dementia and the second most common of all dementias. The present paper aims to define guidelines on the basic principles for treating patients with suspected VaD (and vascular cognitive impairment - no dementia) using an evidence-based, systematized approach. The knowledge used to define these guidelines was retrieved from searches of several databases (Medline, Scielo, Lilacs) containing scientific articles, systematic reviews, meta-analyses, largely published within the last 15 years or earlier when pertinent. Information retrieved and selected for relevance was used to analyze diagnostic criteria and to propose a diagnostic system encompassing diagnostic criteria, anamnesis, as well as supplementary and clinical exams (neuroimaging and laboratory). Wherever possible, instruments were selected that had versions previously adapted and validated for use in Brazil that take into account both schooling and age. This task led to proposed protocols for supplementary exams based on degree of priority, for application in clinical practice and research settings. PMID:29213752

  2. Verification of performance specifications of a molecular test: cystic fibrosis carrier testing using the Luminex liquid bead array.

    PubMed

    Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris

    2012-01-01

    The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.

  3. Intelligent QoS routing algorithm based on improved AODV protocol for Ad Hoc networks

    NASA Astrophysics Data System (ADS)

    Huibin, Liu; Jun, Zhang

    2016-04-01

    Mobile Ad Hoc Networks were playing an increasingly important part in disaster reliefs, military battlefields and scientific explorations. However, networks routing difficulties are more and more outstanding due to inherent structures. This paper proposed an improved cuckoo searching-based Ad hoc On-Demand Distance Vector Routing protocol (CSAODV). It elaborately designs the calculation methods of optimal routing algorithm used by protocol and transmission mechanism of communication-package. In calculation of optimal routing algorithm by CS Algorithm, by increasing QoS constraint, the found optimal routing algorithm can conform to the requirements of specified bandwidth and time delay, and a certain balance can be obtained among computation spending, bandwidth and time delay. Take advantage of NS2 simulation software to take performance test on protocol in three circumstances and validate the feasibility and validity of CSAODV protocol. In results, CSAODV routing protocol is more adapt to the change of network topological structure than AODV protocol, which improves package delivery fraction of protocol effectively, reduce the transmission time delay of network, reduce the extra burden to network brought by controlling information, and improve the routing efficiency of network.

  4. Prosthesis Prescription Protocol of the Arm (PPP-Arm): The implementation of a national prosthesis prescription protocol.

    PubMed

    Wijdenes, Paula; Brouwers, Michael; van der Sluis, Corry K

    2018-02-01

    In order to create more uniformity in the prescription of upper limb prostheses by Dutch rehabilitation teams, the development and implementation of a Prosthesis Prescription Protocol of the upper limb (PPP-Arm) was initiated. The aim was to create a national digital protocol to structure, underpin, and evaluate the prescription of upper limb prostheses for clients with acquired or congenital arm defects. Prosthesis Prescription Protocol of the Arm (PPP-Arm) was developed on the basis of the International Classification of Functioning and consisted of several layers. All stakeholders (rehabilitation teams, orthopedic workshops, patients, and insurance companies) were involved in development and implementation. A national project coordinator and knowledge brokers in each team were essential for the project. PPP-Arm was successfully developed and implemented in nine Dutch rehabilitation teams. The protocol improved team collaboration, structure, and completeness of prosthesis prescriptions and treatment uniformity and might be interesting for other countries as well. Clinical relevance A national protocol to prescribe upper limb prostheses can be helpful to create uniformity in treatment of patients with upper limb defects. Such a protocol improves quality of care for all patients in the country.

  5. Evidence-based development of a diagnosis-dependent therapy planning system and its implementation in modern diagnostic software.

    PubMed

    Ahlers, M O; Jakstat, H A

    2005-07-01

    The prerequisite for structured individual therapy of craniomandibular dysfunctions is differential diagnostics. Suggestions for the structured recording of findings and their structured evaluation beyond the global diagnosis of "craniomandibular disorders" have been published. Only this structured approach enables computerization of the diagnostic process. The respective software is available for use in practice (CMDcheck for CMD screening, CMDfact for the differential diagnostics). Based on this structured diagnostics, knowledge-based therapy planning is also conceivable. The prerequisite for this would be a model of achieving consensus on the indicated forms of therapy related to the diagnosis. Therefore, a procedure for evidence-based achievement of consensus on suitable forms of therapy in CMD was developed first in multicentric cooperation, and then implemented in corresponding software. The clinical knowledge of experienced specialists was included consciously for the consensus achievement process. At the same time, anonymized mathematical statistical evaluations were used for control and objectification. Different examiners form different departments of several universities working independently of one another assigned the theoretically conceiveable therapeutic alternatives to the already published diagnostic scheme. After anonymization, the correlation of these assignments was then calculated mathematically. For achieving consensus in those cases for which no agreement initally existed, agreement was subsequently arrived at in the course of a consensus conference on the basis of literature evaluations and the discussion of clinical case examples. This consensus in turn finally served as the basis of a therapy planner implemented in the above-mentioned diagnostic software CMDfact. Contributing to quality assurance, the principles of programming this assistant as well as the interface for linking into the diagnostic software are documented and also published here.

  6. The Relationship between Types of Attention and Auditory Processing Skills: Reconsidering Auditory Processing Disorder Diagnosis

    PubMed Central

    Stavrinos, Georgios; Iliadou, Vassiliki-Maria; Edwards, Lindsey; Sirimanna, Tony; Bamiou, Doris-Eva

    2018-01-01

    Measures of attention have been found to correlate with specific auditory processing tests in samples of children suspected of Auditory Processing Disorder (APD), but these relationships have not been adequately investigated. Despite evidence linking auditory attention and deficits/symptoms of APD, measures of attention are not routinely used in APD diagnostic protocols. The aim of the study was to examine the relationship between auditory and visual attention tests and auditory processing tests in children with APD and to assess whether a proposed diagnostic protocol for APD, including measures of attention, could provide useful information for APD management. A pilot study including 27 children, aged 7–11 years, referred for APD assessment was conducted. The validated test of everyday attention for children, with visual and auditory attention tasks, the listening in spatialized noise sentences test, the children's communication checklist questionnaire and tests from a standard APD diagnostic test battery were administered. Pearson's partial correlation analysis examining the relationship between these tests and Cochrane's Q test analysis comparing proportions of diagnosis under each proposed battery were conducted. Divided auditory and divided auditory-visual attention strongly correlated with the dichotic digits test, r = 0.68, p < 0.05, and r = 0.76, p = 0.01, respectively, in a sample of 20 children with APD diagnosis. The standard APD battery identified a larger proportion of participants as having APD, than an attention battery identified as having Attention Deficits (ADs). The proposed APD battery excluding AD cases did not have a significantly different diagnosis proportion than the standard APD battery. Finally, the newly proposed diagnostic battery, identifying an inattentive subtype of APD, identified five children who would have otherwise been considered not having ADs. The findings show that a subgroup of children with APD demonstrates underlying sustained and divided attention deficits. Attention deficits in children with APD appear to be centred around the auditory modality but further examination of types of attention in both modalities is required. Revising diagnostic criteria to incorporate attention tests and the inattentive type of APD in the test battery, provides additional useful data to clinicians to ensure careful interpretation of APD assessments. PMID:29441033

  7. Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol

    PubMed Central

    Wilson, Claire; Blackwood, Bronagh; McAuley, Danny F; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Warhurst, Geoffrey

    2012-01-01

    Background There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. Registration PROSPERO—NIHR Prospective Register of Systematic Reviews (CRD42011001289). PMID:22240646

  8. Evaluation of Quality Assessment Protocols for High Throughput Genome Resequencing Data

    PubMed Central

    Chiara, Matteo; Pavesi, Giulio

    2017-01-01

    Large-scale initiatives aiming to recover the complete sequence of thousands of human genomes are currently being undertaken worldwide, concurring to the generation of a comprehensive catalog of human genetic variation. The ultimate and most ambitious goal of human population scale genomics is the characterization of the so-called human “variome,” through the identification of causal mutations or haplotypes. Several research institutions worldwide currently use genotyping assays based on Next-Generation Sequencing (NGS) for diagnostics and clinical screenings, and the widespread application of such technologies promises major revolutions in medical science. Bioinformatic analysis of human resequencing data is one of the main factors limiting the effectiveness and general applicability of NGS for clinical studies. The requirement for multiple tools, to be combined in dedicated protocols in order to accommodate different types of data (gene panels, exomes, or whole genomes) and the high variability of the data makes difficult the establishment of a ultimate strategy of general use. While there already exist several studies comparing sensitivity and accuracy of bioinformatic pipelines for the identification of single nucleotide variants from resequencing data, little is known about the impact of quality assessment and reads pre-processing strategies. In this work we discuss major strengths and limitations of the various genome resequencing protocols are currently used in molecular diagnostics and for the discovery of novel disease-causing mutations. By taking advantage of publicly available data we devise and suggest a series of best practices for the pre-processing of the data that consistently improve the outcome of genotyping with minimal impacts on computational costs. PMID:28736571

  9. Cognitive behaviour therapy for chronic fatigue syndrome: Differences in treatment outcome between a tertiary treatment centre in the United Kingdom and the Netherlands.

    PubMed

    Worm-Smeitink, M; Nikolaus, S; Goldsmith, K; Wiborg, J; Ali, S; Knoop, H; Chalder, T

    2016-08-01

    Cognitive behaviour therapy (CBT) reduces fatigue and disability in chronic fatigue syndrome (CFS). However, outcomes vary between studies, possibly because of differences in patient characteristics, treatment protocols, diagnostic criteria and outcome measures. The objective was to compare outcomes after CBT in tertiary treatment centres in the Netherlands (NL) and the United Kingdom (UK), using different treatment protocols but identical outcome measures, while controlling for differences in patient characteristics and diagnostic criteria. Consecutively referred CFS patients who received CBT were included (NL: n=293, UK: n=163). Uncontrolled effect sizes for improvement in fatigue (Chalder Fatigue Questionnaire), physical functioning (SF-36 physical functioning subscale) and social functioning (Work and Social Adjustment Scale) were compared. Multiple regression analysis was used to examine whether patient differences explained outcome differences between centres. Effect sizes differed between centres for fatigue (Cohen's D NL=1.74, 95% CI=1.52-1.95; UK=0.99, CI=0.73-1.25), physical functioning (NL=0.99, CI=0.81-1.18; UK=0.33, CI=0.08-0.58) and social functioning (NL=1.47, CI=1.26-1.69; UK=0.61, CI=0.35-0.86). Patients in the UK had worse physical functioning at baseline and there were minor demographic differences. These could not explain differences in centre outcome. Effectiveness of CBT differed between treatment centres. Differences in treatment protocols may explain this and should be investigated to help further improve outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Approach to Anemia in Hospitalized Patients with Infectious Diseases; Is it Appropriate?

    PubMed

    Entezari-Maleki, Taher; Khalili, Hossein; Karimzadeh, Iman; Jafari, Sirous

    2015-01-01

    Anemia of chronic diseases (ACD) is a common problem in patients with infectious diseases and can influence the quality of life and patients' survival. Despite the clinical importance of ACD, data are still lacking regarding this problem in the infectious diseases. This study aimed to evaluate the prevalence, related factors, outcome and approaches to anemia in the infectious diseases ward. This retrospective study was performed to review the medical records of patients admitted to the infectious diseases department of Imam Khomeini hospital during a two-year period between 2009 and 2011. A standard protocol was developed to evaluate anemia. Patients' demographic data approaches to manage anemia and routine laboratory tests were recorded and compared with the protocol. Totally, 1,120 medical records were reviewed. ACD was recognized in 705 patients (63%). Only 5.1% of diagnostic and 8.7% of treatment approaches was based on the protocol. The majority of patients (89.4%) were received inappropriate treatment regarding. Mortality rate of patients with ACD was 3.4%. Moreover, a significant correlation between anemia and mortality was detected (r = 0.131; p = 0.026). A statistically significant correlation was also identified between patients' Hgb and ESR, CRP, reasons of admission, number of medications, and underlying diseases. In conclusion, results of this study suggested that ACD is a common problem in infectious diseases patients and significantly associated with patients' mortality. Moreover, the majority of studied patients were not received an appropriate diagnostic and treatment approach which arises more concerns regarding the management of ACD in infectious diseases setting.

  11. Hematoxylin and Eosin Counterstaining Protocol for Immunohistochemistry Interpretation and Diagnosis.

    PubMed

    Grosset, Andrée-Anne; Loayza-Vega, Kevin; Adam-Granger, Éloïse; Birlea, Mirela; Gilks, Blake; Nguyen, Bich; Soucy, Geneviève; Tran-Thanh, Danh; Albadine, Roula; Trudel, Dominique

    2017-12-21

    Hematoxylin and eosin (H&E) staining is a well-established technique in histopathology. However, immunohistochemistry (IHC) interpretation is done exclusively with hematoxylin counterstaining. Our goal was to investigate the potential of H&E as counterstaining (H&E-IHC) to allow for visualization of a marker while confirming the diagnosis on the same slide. The quality of immunostaining and the fast-technical performance were the main criteria to select the final protocol. We stained multiple diagnostic tissues with class I IHC tests with different subcellular localization markers (anti-CK7, CK20, synaptophysin, CD20, HMB45, and Ki-67) and with double-staining on prostate tissues with anti-high molecular weight keratins/p63 (DAB detection) and p504s (alkaline phosphatase detection). To validate the efficacy of the counterstaining, we stained tissue microarrays from the Canadian Immunohistochemistry Quality Control (cIQc) with class II IHC tests (ER, PR, HER2, and p53 markers). Interobserver and intraobserver concordance was assessed by κ statistics. Excellent agreement of H&E-IHC interpretation was observed in comparison with standard IHC from our laboratory (κ, 0.87 to 1.00), and with the cIQc reference values (κ, 0.81 to 1.00). Interobserver and intraobserver agreement was excellent (κ, 0.89 to 1.00 and 0.87 to 1.00, respectively). We therefore show for the first time the potential of using H&E counterstaining for IHC interpretation. We recommend the H&E-IHC protocol to enhance diagnostic precision for the clinical workflow and research studies.

  12. An International Survey of Brain Banking Operation and Characterization Practices

    PubMed Central

    Palmer-Aronsten, Beatrix; McCrossin, Toni; Kril, Jillian

    2016-01-01

    Brain banks continue to make a major contribution to the study of neurological and psychiatric disorders. The current complexity and scope of research heighten the need for well-characterized cases and the demand for larger cohorts and necessitate strategies, such as the establishment of bank networks based in regional areas. While individual brain banks have developed protocols that meet researchers' needs within the confines of resources and funding, to further promote collaboration, standardization and scientific validity and understanding of the current protocols of participating banks are required. A survey was sent to brain banks, identified by an Internet search, to investigate operational protocols, case characterization, cohort management, data collection, standardization, and degree of collaboration between banks. The majority of the 24 banks that returned the survey have been established for more than 20 years, and most are affiliated with a regional network. While prospective donor programs were the primary source of donation, the data collected on donors varied. Longitudinal information assists case characterization and enhances the analysis capabilities of research. However, acquiring this information depended on the availability of qualified staff. Respondents indicated a high level of importance for standardization, but only 8 of 24 considered this occurred between banks. Standard diagnostic criteria were not achieved in the classification of controls, and some banks relied on the researcher to indicate the criteria for classification of controls. Although the capacity to collaborate with other banks was indicated by 16 of 24 banks, this occurred infrequently. Engagement of all brain banks to participate toward a consensus of diagnostic tools, especially for controls, will strengthen collaboration. PMID:27399803

  13. An International Survey of Brain Banking Operation and Characterization Practices.

    PubMed

    Palmer-Aronsten, Beatrix; Sheedy, Donna; McCrossin, Toni; Kril, Jillian

    2016-12-01

    Brain banks continue to make a major contribution to the study of neurological and psychiatric disorders. The current complexity and scope of research heighten the need for well-characterized cases and the demand for larger cohorts and necessitate strategies, such as the establishment of bank networks based in regional areas. While individual brain banks have developed protocols that meet researchers' needs within the confines of resources and funding, to further promote collaboration, standardization and scientific validity and understanding of the current protocols of participating banks are required. A survey was sent to brain banks, identified by an Internet search, to investigate operational protocols, case characterization, cohort management, data collection, standardization, and degree of collaboration between banks. The majority of the 24 banks that returned the survey have been established for more than 20 years, and most are affiliated with a regional network. While prospective donor programs were the primary source of donation, the data collected on donors varied. Longitudinal information assists case characterization and enhances the analysis capabilities of research. However, acquiring this information depended on the availability of qualified staff. Respondents indicated a high level of importance for standardization, but only 8 of 24 considered this occurred between banks. Standard diagnostic criteria were not achieved in the classification of controls, and some banks relied on the researcher to indicate the criteria for classification of controls. Although the capacity to collaborate with other banks was indicated by 16 of 24 banks, this occurred infrequently. Engagement of all brain banks to participate toward a consensus of diagnostic tools, especially for controls, will strengthen collaboration.

  14. Quantitative Comparison of 21 Protocols for Labeling Hippocampal Subfields and Parahippocampal Subregions in In Vivo MRI: Towards a Harmonized Segmentation Protocol

    PubMed Central

    Yushkevich, Paul A.; Amaral, Robert S. C.; Augustinack, Jean C.; Bender, Andrew R.; Bernstein, Jeffrey D.; Boccardi, Marina; Bocchetta, Martina; Burggren, Alison C.; Carr, Valerie A.; Chakravarty, M. Mallar; Chetelat, Gael; Daugherty, Ana M.; Davachi, Lila; Ding, Song-Lin; Ekstrom, Arne; Geerlings, Mirjam I.; Hassan, Abdul; Huang, Yushan; Iglesias, Eugenio; La Joie, Renaud; Kerchner, Geoffrey A.; LaRocque, Karen F.; Libby, Laura A.; Malykhin, Nikolai; Mueller, Susanne G.; Olsen, Rosanna K.; Palombo, Daniela J.; Parekh, Mansi B; Pluta, John B.; Preston, Alison R.; Pruessner, Jens C.; Ranganath, Charan; Raz, Naftali; Schlichting, Margaret L.; Schoemaker, Dorothee; Singh, Sachi; Stark, Craig E. L.; Suthana, Nanthia; Tompary, Alexa; Turowski, Marta M.; Van Leemput, Koen; Wagner, Anthony D.; Wang, Lei; Winterburn, Julie L.; Wisse, Laura E.M.; Yassa, Michael A.; Zeineh, Michael M.

    2015-01-01

    OBJECTIVE An increasing number of human in vivo magnetic resonance imaging (MRI) studies have focused on examining the structure and function of the subfields of the hippocampal formation (the dentate gyrus, CA fields 1–3, and the subiculum) and subregions of the parahippocampal gyrus (entorhinal, perirhinal, and parahippocampal cortices). The ability to interpret the results of such studies and to relate them to each other would be improved if a common standard existed for labeling hippocampal subfields and parahippocampal subregions. Currently, research groups label different subsets of structures and use different rules, landmarks, and cues to define their anatomical extents. This paper characterizes, both qualitatively and quantitatively, the variability in the existing manual segmentation protocols for labeling hippocampal and parahippocampal substructures in MRI, with the goal of guiding subsequent work on developing a harmonized substructure segmentation protocol. METHOD MRI scans of a single healthy adult human subject were acquired both at 3 Tesla and 7 Tesla. Representatives from 21 research groups applied their respective manual segmentation protocols to the MRI modalities of their choice. The resulting set of 21 segmentations was analyzed in a common anatomical space to quantify similarity and identify areas of agreement. RESULTS The differences between the 21 protocols include the region within which segmentation is performed, the set of anatomical labels used, and the extents of specific anatomical labels. The greatest overall disagreement among the protocols is at the CA1/subiculum boundary, and disagreement across all structures is greatest in the anterior portion of the hippocampal formation relative to the body and tail. CONCLUSIONS The combined examination of the 21 protocols in the same dataset suggests possible strategies towards developing a harmonized subfield segmentation protocol and facilitates comparison between published studies. PMID:25596463

  15. Exponentially Decelerated Contrast Media Injection Rate Combined With a Novel Patient-Specific Contrast Formula Reduces Contrast Volume Administration and Radiation Dose During Computed Tomography Pulmonary Angiography.

    PubMed

    Saade, Charbel; Mayat, Ahmad; El-Merhi, Fadi

    2016-01-01

    Matching contrast injection timing with vessel dynamics significantly improves vessel opacification and reduces contrast dose in the assessment of pulmonary embolism during computed tomography (CT) pulmonary angiography. The aim of this study was to investigate opacification of the pulmonary vasculature (PV) during CT pulmonary angiography using a patient-specific contrast formula (PSCF) and exponentially decelerated contrast media (EDCM) injection rate. Institutional review board approved this retrospective study. Computed tomography pulmonary angiography was performed on 200 patients with suspected pulmonary embolism using a 64-channel CT scanner. Patient demographics were equally distributed. Patients were randomly assigned to 2 equal protocol groups: protocol A used a PSCF, and protocol B involved the use of a PSCF combined with EDCM. The mean cross-sectional opacification profile of 8 central and 11 peripheral PVs were measured for each patient, and arteriovenous contrast ratio was calculated. Protocols were compared using Mann-Whitney U nonparametric statistics. Jackknife alternative free-response receiver operating characteristic analyses were used to assess diagnostic efficacy. Interobserver variations were investigated using kappa methods. A number of pulmonary arteries demonstrated increases in opacification (P < 0.02) for protocol B compared with A, whereas opacification in all veins was reduced in protocol B (P < 0.03). Subsequently, increased arteriovenous contrast ratio in protocol B compared with A was observed at all anatomic locations (P < 0.0002). An increase in jackknife alternative free-response receiver operating characteristic figure of merit (P < 0.0002) and interobserver variation was observed with protocol B compared with protocol A (κ = 0.3-0.73). Mean contrast volume was reduced in protocol B (29 [4] mL) compared with protocol A (33 [9] mL). Mean effective radiation dose in protocol B (1.2 [0.4] mSv) was reduced by 14% compared with protocol A (1.4 [0.6] mSv). Significant improvements in visualization of the PV can be achieved with a low contrast volume using an EDCM and PSCF. The reduced risk of cancer induction is highlighted.

  16. Diagnostic efficiency of abattoir meat inspection service in Ethiopia to detect carcasses infected with Mycobacterium bovis: implications for public health.

    PubMed

    Biffa, Demelash; Bogale, Asseged; Skjerve, Eystein

    2010-08-06

    Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa

  17. Diagnostic efficiency of abattoir meat inspection service in Ethiopia to detect carcasses infected with Mycobacterium bovis: Implications for public health

    PubMed Central

    2010-01-01

    Background Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. Methods The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. Results There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa ≤ 0.2). RA inspection was able to detect only 117 of the total 3322 carcasses inspected (3.5%). The sensitivity (Sn) and specificity (Sp) of RA inspection were 28.2% (95/337) [95%CI: 23.4-33.0] and 99.3% (2963/2985) [95%CI: 99.0-99.6], respectively, when DA inspection was considered as reference test. When culture and microscopy (CM) was considered as reference test, the Sn and Sp of RA were 55.2% (58/105) [95%CI: 45.7-64.7] and 84.1% (195/232) [95%CI: 79.3-88.8]. RA inspection failed to detect 71.8% (242/337) and 44.8% (47/105) of TB infected carcasses as judged by DA inspection and CM, respectively. On the other hand, a much higher sensitivity of DA was obtained when CM and RD deletion analysis were considered as reference tests (96.3% (105/109) and 100.0% (24/24), respectively). Conclusions The study results indicate that meat inspection protocols currently utilized in abattoirs are insufficient to detect the majority of TB lesions at the gross level. DA inspection protocols were demonstrated to improve the detection level by approximately 3-fold. The failure of current inspection techniques to detect approximately 70% of carcasses presented with grossly-visible lesions of TB at the slaughter-plants indicates the magnitude of meat-borne zoonotic TB as an on-going risk to public health. Standardization of abattoir inspection protocols (in line with international sanitary requirements), enhanced training and proficiency testing of meat inspections, and raising public awareness are recommended as essential and cost-effective interventions to improve meat inspection service in Ethiopia, with subsequent protection of consumers' health. PMID:20691081

  18. Protocols for Image Processing based Underwater Inspection of Infrastructure Elements

    NASA Astrophysics Data System (ADS)

    O'Byrne, Michael; Ghosh, Bidisha; Schoefs, Franck; Pakrashi, Vikram

    2015-07-01

    Image processing can be an important tool for inspecting underwater infrastructure elements like bridge piers and pile wharves. Underwater inspection often relies on visual descriptions of divers who are not necessarily trained in specifics of structural degradation and the information may often be vague, prone to error or open to significant variation of interpretation. Underwater vehicles, on the other hand can be quite expensive to deal with for such inspections. Additionally, there is now significant encouragement globally towards the deployment of more offshore renewable wind turbines and wave devices and the requirement for underwater inspection can be expected to increase significantly in the coming years. While the merit of image processing based assessment of the condition of underwater structures is understood to a certain degree, there is no existing protocol on such image based methods. This paper discusses and describes an image processing protocol for underwater inspection of structures. A stereo imaging image processing method is considered in this regard and protocols are suggested for image storage, imaging, diving, and inspection. A combined underwater imaging protocol is finally presented which can be used for a variety of situations within a range of image scenes and environmental conditions affecting the imaging conditions. An example of detecting marine growth is presented of a structure in Cork Harbour, Ireland.

  19. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill.

    PubMed

    Lichtenstein, Daniel A

    2015-06-01

    This review article describes two protocols adapted from lung ultrasound: the bedside lung ultrasound in emergency (BLUE)-protocol for the immediate diagnosis of acute respiratory failure and the fluid administration limited by lung sonography (FALLS)-protocol for the management of acute circulatory failure. These applications require the mastery of 10 signs indicating normal lung surface (bat sign, lung sliding, A-lines), pleural effusions (quad and sinusoid sign), lung consolidations (fractal and tissue-like sign), interstitial syndrome (lung rockets), and pneumothorax (stratosphere sign and the lung point). These signs have been assessed in adults, with diagnostic accuracies ranging from 90% to 100%, allowing consideration of ultrasound as a reasonable bedside gold standard. In the BLUE-protocol, profiles have been designed for the main diseases (pneumonia, congestive heart failure, COPD, asthma, pulmonary embolism, pneumothorax), with an accuracy > 90%. In the FALLS-protocol, the change from A-lines to lung rockets appears at a threshold of 18 mm Hg of pulmonary artery occlusion pressure, providing a direct biomarker of clinical volemia. The FALLS-protocol sequentially rules out obstructive, then cardiogenic, then hypovolemic shock for expediting the diagnosis of distributive (usually septic) shock. These applications can be done using simple grayscale machines and one microconvex probe suitable for the whole body. Lung ultrasound is a multifaceted tool also useful for decreasing radiation doses (of interest in neonates where the lung signatures are similar to those in adults), from ARDS to trauma management, and from ICUs to points of care. If done in suitable centers, training is the least of the limitations for making use of this kind of visual medicine.

  20. Health Worker Compliance with a 'Test And Treat' Malaria Case Management Protocol in Papua New Guinea.

    PubMed

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M; Hetzel, Manuel W

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a 'test and treat' malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal.

  1. Health Worker Compliance with a ‘Test And Treat’ Malaria Case Management Protocol in Papua New Guinea

    PubMed Central

    Pulford, Justin; Smith, Iso; Mueller, Ivo; Siba, Peter M.; Hetzel, Manuel W.

    2016-01-01

    The Papua New Guinea (PNG) Department of Health introduced a ‘test and treat’ malaria case management protocol in 2011. This study assesses health worker compliance with the test and treat protocol on a wide range of measures, examines self-reported barriers to health worker compliance as well as health worker attitudes towards the test and treat protocol. Data were collected by cross-sectional survey conducted in randomly selected primary health care facilities in 2012 and repeated in 2014. The combined survey data included passive observation of current or recently febrile patients (N = 771) and interviewer administered questionnaires completed with health workers (N = 265). Across the two surveys, 77.6% of patients were tested for malaria infection by rapid diagnostic test (RDT) or microscopy, 65.6% of confirmed malaria cases were prescribed the correct antimalarials and 15.3% of febrile patients who tested negative for malaria infection were incorrectly prescribed an antimalarial. Overall compliance with a strictly defined test and treat protocol was 62.8%. A reluctance to test current/recently febrile patients for malaria infection by RDT or microscopy in the absence of acute malaria symptoms, reserving recommended antimalarials for confirmed malaria cases only and choosing to clinically diagnose a malaria infection, despite a negative RDT result were the most frequently reported barriers to protocol compliance. Attitudinal support for the test and treat protocol, as assessed by a nine-item measure, improved across time. In conclusion, health worker compliance with the full test and treat malaria protocol requires improvement in PNG and additional health worker support will likely be required to achieve this. The broader evidence base would suggest any such support should be delivered over a longer period of time, be multi-dimensional and multi-modal. PMID:27391594

  2. Implementing the American Academy of Pediatrics attention-deficit/hyperactivity disorder diagnostic guidelines in primary care settings.

    PubMed

    Leslie, Laurel K; Weckerly, Jill; Plemmons, Dena; Landsverk, John; Eastman, Sarita

    2004-07-01

    To evaluate the feasibility of the San Diego Attention-Deficit/Hyperactivity Disorder Project (SANDAP) protocol, a pediatric community-initiated quality improvement effort to foster implementation of the American Academy of Pediatrics (AAP) attention-deficit/hyperactivity disorder (ADHD) diagnostic guidelines, and to identify any additional barriers to providing evidence-based ADHD evaluative care. Seven research-naïve primary care offices in the San Diego area were recruited to participate. Offices were trained in the SANDAP protocol, which included 1) physician education, 2) a standardized assessment packet for parents and teachers, 3) an ADHD coordinator to assist in collection and collation of the assessment packet components, 4) educational materials for clinicians, parents, and teachers, in the form of handouts and a website, and 5) flowcharts delineating local paths for referral to medical subspecialists, mental health practitioners, and school-based professionals. The assessment packet included the parent and teacher versions of the Vanderbilt ADHD Diagnostic Rating Scales. In this study, we chose a conservative interpretation of the AAP ADHD guidelines for diagnosing ADHD, requiring that a child met criteria for ADHD on both the parent and teacher rating scales. A mixed-method analytic strategy was used to address feasibility and barriers, including quantitative surveys with parents and teachers and qualitative debriefing sessions conducted an average of 3 times per year with pediatricians and office staff members. Between December 2000 and April 2003, 159 children were consecutively enrolled for evaluation of school and/or behavioral problems. Clinically, only 44% of the children met criteria for ADHD on both the parent and teacher scales, and 73.5% of those children were categorized as having the combined subtype. More than 40% of the subjects demonstrated discrepant results on the Vanderbilt scales, with only the parent or teacher endorsing sufficient symptoms to meet the criteria of the Diagnostic and Statistical Manual of Mental Disorders, 4th ed. Other mental health and learning problems were common in the sample; 58.5% of subjects met screening criteria for oppositional defiant disorder/conduct disorder, 32.7% met screening criteria for anxiety/depression, and approximately one-third had an active individualized education program in place or had received an individualized education program in the past. On evaluation, the SANDAP protocol was acceptable and feasible for all stakeholders. However, additional barriers to implementing the AAP ADHD guidelines were identified, including 1) limited information in the guidelines regarding the use of specific ADHD rating scales, the evaluation and treatment of children with discrepant and/or negative results, and the indications for psychologic evaluation of learning problems, 2) families' need for education regarding ADHD and support, 3) characteristics of physical health and mental health plans that limited care for children with ADHD, and 4) limited knowledge and use of potential community resources. Our results indicate that children presenting for evaluation of possible ADHD in primary care offices have complex clinical characteristics. Providers need mechanisms for implementing the ADHD diagnostic guidelines that address the physician education and delivery system design aspects of care that were developed in the SANDAP protocol. Additional barriers were also identified. Careful attention to these factors will be necessary to ensure the sustained provision of quality care for children with ADHD in primary care settings.

  3. Implementing the American Academy of Pediatrics Attention-Deficit/Hyperactivity Disorder Diagnostic Guidelines in Primary Care Settings

    PubMed Central

    Leslie, Laurel K.; Weckerly, Jill; Plemmons, Dena; Landsverk, John; Eastman, Sarita

    2006-01-01

    Objectives To evaluate the feasibility of the San Diego Attention-Deficit/Hyperactivity Disorder Project (SANDAP) protocol, a pediatric community-initiated quality improvement effort to foster implementation of the American Academy of Pediatrics (AAP) attention-deficit/hyperactivity disorder (ADHD) diagnostic guidelines, and to identify any additional barriers to providing evidence-based ADHD evaluative care. Methods Seven research-naïve primary care offices in the San Diego area were recruited to participate. Offices were trained in the SANDAP protocol, which included 1) physician education, 2) a standardized assessment packet for parents and teachers, 3) an ADHD coordinator to assist in collection and collation of the assessment packet components, 4) educational materials for clinicians, parents, and teachers, in the form of handouts and a website, and 5) flowcharts delineating local paths for referral to medical subspecialists, mental health practitioners, and school-based professionals. The assessment packet included the parent and teacher versions of the Vanderbilt ADHD Diagnostic Rating Scales. In this study, we chose a conservative interpretation of the AAP ADHD guidelines for diagnosing ADHD, requiring that a child met criteria for ADHD on both the parent and teacher rating scales. A mixed-method analytic strategy was used to address feasibility and barriers, including quantitative surveys with parents and teachers and qualitative debriefing sessions conducted an average of 3 times per year with pediatricians and office staff members. Results Between December 2000 and April 2003, 159 children were consecutively enrolled for evaluation of school and/or behavioral problems. Clinically, only 44% of the children met criteria for ADHD on both the parent and teacher scales, and 73.5% of those children were categorized as having the combined subtype. More than 40% of the subjects demonstrated discrepant results on the Vanderbilt scales, with only the parent or teacher endorsing sufficient symptoms to meet the criteria of the Diagnostic and Statistical Manual of Mental Disorders, 4th ed. Other mental health and learning problems were common in the sample; 58.5% of subjects met screening criteria for oppositional defiant disorder/conduct disorder, 32.7% met screening criteria for anxiety/depression, and approximately one-third had an active individualized education program in place or had received an individualized education program in the past. On evaluation, the SANDAP protocol was acceptable and feasible for all stakeholders. However, additional barriers to implementing the AAP ADHD guidelines were identified, including 1) limited information in the guidelines regarding the use of specific ADHD rating scales, the evaluation and treatment of children with discrepant and/or negative results, and the indications for psychologic evaluation of learning problems, 2) families’ need for education regarding ADHD and support, 3) characteristics of physical health and mental health plans that limited care for children with ADHD, and 4) limited knowledge and use of potential community resources. Conclusions Our results indicate that children presenting for evaluation of possible ADHD in primary care offices have complex clinical characteristics. Providers need mechanisms for implementing the ADHD diagnostic guidelines that address the physician education and delivery system design aspects of care that were developed in the SANDAP protocol. Additional barriers were also identified. Careful attention to these factors will be necessary to ensure the sustained provision of quality care for children with ADHD in primary care settings. PMID:15231919

  4. Prototype development and implementation of picture archiving and communications systems based on ISO-OSI standard

    NASA Astrophysics Data System (ADS)

    Martinez, Ralph; Nam, Jiseung

    1992-07-01

    Picture Archiving and Communication Systems (PACS) is an integration of digital image formation in a hospital, which encompasses various imaging equipment, image viewing workstations, image databases, and a high speed network. The integration requires a standardization of communication protocols to connect devices from different vendors. The American College of Radiology and the National Electrical Manufacturers Association (ACR- NEMA) standard Version 2.0 provides a point-to-point hardware interface, a set of software commands, and a consistent set of data formats for PACS. But, it is inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks and an approach were proposed to ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS''s capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization/Open Systems Interconnection (ISO/OSI), TCP/IP protocols, and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the ISO-based protocol into a PACS prototype. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance comparison between the ISO and TCP/IP implementations are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is done by prototyping PACS on available platforms, which are Micro VAX II, DECstation and SUN Workstation.

  5. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    PubMed

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients <18 years and 17 patients >18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (<18 years) separately by using technical dose descriptors and estimated effective dose. Differences in dose were assessed with the Mann-Whitney U test. The median effective dose for the investigative protocol was 0.04 mSv (95% confidence interval [ CI confidence interval ]: 0.034 mSv, 0.10 mSv) for children and 0.05 mSv (95% CI confidence interval : 0.04 mSv, 0.08 mSv) for adults. These doses were much lower than those with conventional CT (median: 0.52 mSv [95% CI confidence interval : 0.31 mSv, 3.90 mSv] for children and 1.12 mSv [95% CI confidence interval : 0.57 mSv, 3.15 mSv] for adults) and of the same order of magnitude as those for conventional radiography (median: 0.012 mSv [95% CI confidence interval : 0.006 mSv, 0.022 mSv] for children and 0.012 mSv [95% CI confidence interval : 0.005 mSv, 0.031 mSv] for adults). All images were rated at least as diagnostically acceptable. Very good agreement was found in overall Bhalla score ( ICC intraclass correlation coefficient , 0.96) with regard to the severity of bronchiectasis ( ICC intraclass correlation coefficient , 0.87) and sacculations and abscesses ( ICC intraclass correlation coefficient , 0.84). Interobserver agreement was excellent ( ICC intraclass correlation coefficient , 0.86-1). For patients with CF cystic fibrosis , a dedicated chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  6. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children.

    PubMed

    Yoon, Haesung; Kim, Myung-Joon; Yoon, Choon-Sik; Choi, Jiin; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung

    2015-03-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique.

  7. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  8. Clinical and Genetic Diagnosis of Nonischemic Sudden Cardiac Death.

    PubMed

    Jiménez-Jáimez, Juan; Alcalde Martínez, Vicente; Jiménez Fernández, Miriam; Bermúdez Jiménez, Francisco; Rodríguez Vázquez Del Rey, María Del Mar; Perin, Francesca; Oyonarte Ramírez, José Manuel; López Fernández, Silvia; de la Torre, Inmaculada; García Orta, Rocío; González Molina, Mercedes; Cabrerizo, Elisa María; Álvarez Abril, Beatriz; Álvarez, Miguel; Macías Ruiz, Rosa; Correa, Concepción; Tercedor, Luis

    2017-10-01

    Nonischemic sudden cardiac death (SCD) is predominantly caused by cardiomyopathies and channelopathies. There are many diagnostic tests, including some complex techniques. Our aim was to analyze the diagnostic yield of a systematic diagnostic protocol in a specialized unit. The study included 56 families with at least 1 index case of SCD (resuscitated or not). Survivors were studied with electrocardiogram, advanced cardiac imaging, exercise testing, familial study, genetic testing and, in some cases, pharmacological testing. Families with deceased probands were studied using the postmortem findings, familial evaluation, and molecular autopsy with next-generation sequencing (NGS). A positive diagnosis was obtained in 80.4% of the cases, with no differences between survivors and nonsurvivors (P=.53). Cardiac channelopathies were more prevalent among survivors than nonsurvivors (66.6% vs 40%, P=.03). Among the 30 deceased probands, the definitive diagnosis was given by autopsy in 7. A diagnosis of cardiomyopathy tended to be associated with a higher event rate in the family. Genetic testing with NGS was performed in 42 index cases, with a positive result in 28 (66.6%), with no differences between survivors and nonsurvivors (P=.21). There is a strong likelihood of reaching a diagnosis in SCD after a rigorous protocol, with a more prevalent diagnosis of channelopathy among survivors and a worse familial prognosis in cardiomyopathies. Genetic testing with NGS is useful and its value is increasing with respect to the Sanger method. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  9. [Theoretical grounds of a structural and functional model for quality assurance of radiation diagnostics under conditions of development of the modern health care system in Ukraine].

    PubMed

    Korop, Oleg A; Lenskykh, Sergiy V

    2018-01-01

    Introduction: Modern changes in the health care system of Ukraine are focused on financial support in providing medical and diagnostic care to the population and are based on deep and consistent structural and functional transformations. They are aimed at providing adequate quality care, which is the main target function and a principal criterion for operation of health care system. The urgency of this problem is increasing in the context of reforming the health care system and global changes in the governmental financial guarantees for the provision of medical services to the population. The aim of the work is to provide theoretical grounds for a structural and functional model of quality assurance of radiation diagnostics at all levels of medical care given to the population under the current health care reform in Ukraine. Materials and methods: The object of the study is organizing the operation of the radiation diagnostic service; the information is based on the actual data on the characteristics of radiation diagnosis at different levels of medical care provision. Methods of systematic approach, system analysis and structural and functional analysis of the operating system of radiation diagnostics are used. Review: The basis of the quality assurance model is the cyclical process, which includes the stages of the problem identifition, planning of its solution, organization of the system for implementation of decisions, monitoring the quality management process of the radiation diagnostics, and factors influencing the quality of the radiation diagnostics service. These factors include the quality of the structure, process, results, organization of management and control of current processes and the results of radiation diagnostics management. Conclusions: The advantages of the proposed model for ensuring the quality of the radiation diagnostics service are its systemacy and complexity, elimination of identified defects and deficiencies, and achievement of profitability through modern redistribution and use of existing resources of the health care system. The results of adequate service quality management activities in radiation diagnostics are the improvement of organizational and economic principles along with legislative regulation, the implementation of a modern system of radiation diagnostics in the state health care at the national and regional levels, the increase of the accessibility, quality and efficiency of the radiation diagnostics service.

  10. [Validity of three methods for inmuno-diagnostic of neurocysticercosis: systematic review of the literature with meta-analysis 1960-2014].

    PubMed

    Cardona-Arias, Jaiberth Antonio; Carrasquilla-Agudelo, Yoneida Elena; Restrepo-Posada, Deisy Cristina

    2017-02-01

    The screening of neurocysticercosis is complex and immunological methods have varying validity. To evaluate the validity of ELISA for antigen and antibody, and EITB for antibody in the screening of neurocysticercosis. Meta-analysis of diagnostic tests with an ex-ante protocol implemented in five databases with 15 search strategies, ensuring reproducibility in the selection and extraction of information. Sensitivity, specificity, likelihood ratios (LR), diagnostic odds ratio and ROC curve were estimated in MetaDiSc, and predictive values, and Youden index were estimated in Epidat. EITB presented sensitivity of 85.7% (95% CI 83.5-87.7), specificity 93.9% (95% CI = 92.7-95.0), PLR 19.6 (95% CI = 8,6-44.6), NLR 0.16 (95% CI = 0.12-0.21), OR diagnostic 136.2 (95% CI = 54.7-342.6) and area under the curve 0.926. In ELISA for antibody sensitivity was 87.5% (95% CI = 86.1-88.8), specificity 92.2% (95% CI = 91.4-93.0), PLR 11.3 (95% CI = 8.45-15.11), NLR 0.15 (95% CI = 0.13-0.18), diagnostic OR 87.4 (95% CI = 60.1-127.1) and area under the curve 0.950. ELISA for antigen showed low diagnostic validity. No differences were found in these parameters by sample, antigen or antibody type. ELISA for antibodies and EITB have a similar diagnostic value, detection of serum and CSF showed a similar validity.

  11. Uncovering Multivariate Structure in Classroom Observations in the Presence of Rater Errors

    ERIC Educational Resources Information Center

    McCaffrey, Daniel F.; Yuan, Kun; Savitsky, Terrance D.; Lockwood, J. R.; Edelen, Maria O.

    2015-01-01

    We examine the factor structure of scores from the CLASS-S protocol obtained from observations of middle school classroom teaching. Factor analysis has been used to support both interpretations of scores from classroom observation protocols, like CLASS-S, and the theories about teaching that underlie them. However, classroom observations contain…

  12. Utility of the International Classification of Functioning, Disability and Health (ICF) for educational psychologists’ work

    PubMed Central

    Aljunied, Mariam; Frederickson, Norah

    2014-01-01

    Despite embracing a bio-psycho-social perspective, the World Health Organization’s International Classification of Functioning, Disability and Health (ICF) assessment framework has had limited application to date with children who have special educational needs (SEN). This study examines its utility for educational psychologists’ work with children who have Autism Spectrum Disorders (ASD). Mothers of 40 children with ASD aged eight to 12 years were interviewed using a structured protocol based on the ICF framework. The Diagnostic Interview for Social and Communication Disorder (DISCO) was completed with a subset of 19 mothers. Internal consistency and inter-rater reliability of the interview assessments were found to be acceptable and there was evidence for concurrent and discriminant validity. Despite some limitations, initial support for the utility of the ICF model suggests its potential value across educational, health and care fields. Further consideration of its relevance to educational psychologists in new areas of multi-agency working is warranted. PMID:26157197

  13. Microscale oxygraphy reveals OXPHOS impairment in MRC mutant cells

    PubMed Central

    Invernizzi, F.; D'Amato, I.; Jensen, P.B.; Ravaglia, S.; Zeviani, M.; Tiranti, V.

    2012-01-01

    Given the complexity of the respiratory chain structure, assembly and regulation, the diagnostic workout for the identification of defects of oxidative phosphorylation (OXPHOS) is a major challenge. Spectrophotometric assays, that measure the activity of individual respiratory complexes in tissue and cell homogenates or isolated mitochondria, are highly specific, but their utilization is limited by the availability of sufficient biological material and intrinsic sensitivity. A further limitation is tissue specificity, which usually determines attenuation, or disappearance, in cultured fibroblasts, of defects detected in muscle or liver. We used numerous fibroblast cell lines derived from patients with OXPHOS deficiencies to set up experimental protocols required for the direct readout of cellular respiration using the Seahorse XF96 apparatus, which measures oxygen consumption rate (OCR) and extra-cellular acidification rate (ECAR) in 96 well plates. Results demonstrate that first level screening based on microscale oxygraphy is more sensitive, cheaper and rapid than spectrophotometry for the biochemical evaluation of cells from patients with suspected mitochondrial disorders. PMID:22310368

  14. Investigator initiated IBD trials in the US: Facts, obstacles and answers

    PubMed Central

    Herfarth, Hans H; Jackson, Susan; Schliebe, Barbara G.; Martin, Christopher; Ivanova, Anastasia; Anton, Kristen; Sandler, Robert S; Long, Millie D; Isaacs, Kim L; Osterman, Mark T; Sands, Bruce E; Higgins, Peter D; Lewis, James D

    2016-01-01

    Investigator initiated randomized clinical trials (IITs) are the backbone of academic clinical research. IITs complement the large clinical studies sponsored by industry and address questions, which are usually not the main focus of a commercially directed research but have the purpose to confirm, improve or refute clinically important questions with regard to diagnostic and therapeutic approaches in patient care. The aim of this review is to illustrate the necessary steps to start and complete an IIT in the field of inflammatory bowel diseases (IBD) in the US. The initial milestones for an investigator include structuring a protocol, planning and building of the trial infrastructure, accurately estimating the costs of the trial and gauging the time span for recruitment. Once the trial has begun it is important to keep patient recruitment on target, monitor of the data quality, and document treatment emergent adverse events. This article provides a framework for the different phases of an IIT and outlines potential hurdles, which could hinder a successful execution. PMID:27598744

  15. Data acquisition for a real time fault monitoring and diagnosis knowledge-based system for space power system

    NASA Technical Reports Server (NTRS)

    Wilhite, Larry D.; Lee, S. C.; Lollar, Louis F.

    1989-01-01

    The design and implementation of the real-time data acquisition and processing system employed in the AMPERES project is described, including effective data structures for efficient storage and flexible manipulation of the data by the knowledge-based system (KBS), the interprocess communication mechanism required between the data acquisition system and the KBS, and the appropriate data acquisition protocols for collecting data from the sensors. Sensor data are categorized as critical or noncritical data on the basis of the inherent frequencies of the signals and the diagnostic requirements reflected in their values. The critical data set contains 30 analog values and 42 digital values and is collected every 10 ms. The noncritical data set contains 240 analog values and is collected every second. The collected critical and noncritical data are stored in separate circular buffers. Buffers are created in shared memory to enable other processes, i.e., the fault monitoring and diagnosis process and the user interface process, to freely access the data sets.

  16. ECM microenvironment unlocks brown adipogenic potential of adult human bone marrow-derived MSCs.

    PubMed

    Lee, Michelle H; Goralczyk, Anna G; Kriszt, Rókus; Ang, Xiu Min; Badowski, Cedric; Li, Ying; Summers, Scott A; Toh, Sue-Anne; Yassin, M Shabeer; Shabbir, Asim; Sheppard, Allan; Raghunath, Michael

    2016-02-17

    Key to realizing the diagnostic and therapeutic potential of human brown/brite adipocytes is the identification of a renewable, easily accessible and safe tissue source of progenitor cells, and an efficacious in vitro differentiation protocol. We show that macromolecular crowding (MMC) facilitates brown adipocyte differentiation in adult human bone marrow mesenchymal stem cells (bmMSCs), as evidenced by substantially upregulating uncoupling protein 1 (UCP1) and uncoupled respiration. Moreover, MMC also induced 'browning' in bmMSC-derived white adipocytes. Mechanistically, MMC creates a 3D extracellular matrix architecture enshrouding maturing adipocytes in a collagen IV cocoon that is engaged by paxillin-positive focal adhesions also at the apical side of cells, without contact to the stiff support structure. This leads to an enhanced matrix-cell signaling, reflected by increased phosphorylation of ATF2, a key transcription factor in UCP1 regulation. Thus, tuning the dimensionality of the microenvironment in vitro can unlock a strong brown potential dormant in bone marrow.

  17. Nanomaterials Work at NASA-Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Arepalli, Sivaram

    2005-01-01

    Nanomaterials activities at NASA-Johnson Space Center focus on single wall carbon nanotube production, characterization and their applications for aerospace. Nanotubes are produced by arc and laser methods and the growth process is monitored by in-situ diagnostics using time resolved passive emission and laser induced fluorescence of the active species. Parametric study of both these processes are conducted to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, laser fluence and arc current. Characterization of the nanotube material is performed using the NASA-JSC protocol developed by combining analytical techniques of SEM, TEM, UV-VIS-NIR absorption, Raman, and TGA. Efforts at JSC over the past five years in composites have centered on structural polymernanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large surface area as well as high conductivity exhibited by SWCNTs.

  18. A new paper-based platform technology for point-of-care diagnostics.

    PubMed

    Gerbers, Roman; Foellscher, Wilke; Chen, Hong; Anagnostopoulos, Constantine; Faghri, Mohammad

    2014-10-21

    Currently, the Lateral flow Immunoassays (LFIAs) are not able to perform complex multi-step immunodetection tests because of their inability to introduce multiple reagents in a controlled manner to the detection area autonomously. In this research, a point-of-care (POC) paper-based lateral flow immunosensor was developed incorporating a novel microfluidic valve technology. Layers of paper and tape were used to create a three-dimensional structure to form the fluidic network. Unlike the existing LFIAs, multiple directional valves are embedded in the test strip layers to control the order and the timing of mixing for the sample and multiple reagents. In this paper, we report a four-valve device which autonomously directs three different fluids to flow sequentially over the detection area. As proof of concept, a three-step alkaline phosphatase based Enzyme-Linked ImmunoSorbent Assay (ELISA) protocol with Rabbit IgG as the model analyte was conducted to prove the suitability of the device for immunoassays. The detection limit of about 4.8 fm was obtained.

  19. Physics, Techniques and Review of Neuroradiological Applications of Diffusion Kurtosis Imaging (DKI).

    PubMed

    Marrale, M; Collura, G; Brai, M; Toschi, N; Midiri, F; La Tona, G; Lo Casto, A; Gagliardo, C

    2016-12-01

    In recent years many papers about diagnostic applications of diffusion tensor imaging (DTI) have been published. This is because DTI allows to evaluate in vivo and in a non-invasive way the process of diffusion of water molecules in biological tissues. However, the simplified description of the diffusion process assumed in DTI does not permit to completely map the complex underlying cellular components and structures, which hinder and restrict the diffusion of water molecules. These limitations can be partially overcome by means of diffusion kurtosis imaging (DKI). The aim of this paper is the description of the theory of DKI, a new topic of growing interest in radiology. DKI is a higher order diffusion model that is a straightforward extension of the DTI model. Here, we analyze the physics underlying this method, we report our MRI acquisition protocol with the preprocessing pipeline used and the DKI parametric maps obtained on a 1.5 T scanner, and we review the most relevant clinical applications of this technique in various neurological diseases.

  20. RANZCR Body Systems Framework of diagnostic imaging examination descriptors.

    PubMed

    Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia

    2014-08-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.

  1. OSI-compatible protocols for mobile-satellite communications: The AMSS experience

    NASA Technical Reports Server (NTRS)

    Moher, Michael

    1990-01-01

    The protocol structure of the international aeronautical mobile satellite service (AMSS) is reviewed with emphasis on those aspects of protocol performance, validation, and conformance which are peculiar to mobile services. This is in part an analysis of what can be learned from the AMSS experience with protocols which is relevant to the design of other mobile satellite data networks, e.g., land mobile.

  2. Warfighter Neuroendocrinology: Modeling Stress Response, PTSD, and TBI

    DTIC Science & Technology

    studies are challenged by incongruent diagnostic criteria and confounding treatment protocols. Understanding PTSD is not a simple task as there is no...reliable biological predictor or marker for PTSD and diagnoses are heavily reliant on self-reporting. Current treatments include psychotherapy and...pharmacotherapy: it is not very clear how the two intervention methods inform each other and they are not always very successful. In part, these challenges

  3. [Invasive nosocomial pulmonary aspergillosis].

    PubMed

    Germaud, P; Haloun, A

    2001-04-01

    Immunodepressed patients, particularly those with neutropenia or bone marrow or organ grafts, are at risk of developing nosocomial invasive pulmonary aspergilosis. The favoring factors, early diagnostic criteria and curative treatment protocols are well known. Prognosis remains however quite severe with a death rate above 50%. Preventive measures are required for the treatment of these high-risk patients and epidemiology surveillance is needed in case of aspergillosis acquired in the hospital.

  4. "Tennis elbow". A challenging call for computation and medicine

    NASA Astrophysics Data System (ADS)

    Sfetsioris, D.; Bontioti, E. N.

    2014-10-01

    An attempt to give an insight on the features composing this musculotendinous disorder. We address the issues of definition, pathophysiology and the mechanism underlying the onset and the occurrence of the disease, diagnosis and diagnostic tools as well as the methods of treatment. We focus mostly on conservative treatment protocols and we recognize the need for a more thorough investigation with the aid of computation.

  5. SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsh, R; Silosky, M

    2016-06-15

    Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’smore » routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.« less

  6. Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE).

    PubMed

    Lee, Young Han; Hahn, Seok; Lim, Daekeon; Suh, Jin-Suck

    2017-02-01

    Background Conventionally, two-dimensional (2D) fast spin-echo (FSE) sequences have been widely used for clinical cartilage imaging as well as gradient (GRE) sequences. Recently, three-dimensional (3D) volumetric magnetic resonance imaging (MRI) has been introduced with one 3D volumetric scan, and this is replacing slice-by-slice 2D MR scans. Purpose To evaluate the image quality and diagnostic performance of two 3D sequences for abnormalities of knee cartilage: fat-suppressed (FS) FSE-based 3D volume isotropic turbo spin-echo acquisition (VISTA) and GRE-based 3D T1 high-resolution isovolumetric examination (THRIVE). Material and Methods The institutional review board approved the protocol of this retrospective review. This study enrolled 40 patients (41 knees) with arthroscopically confirmed abnormalities of cartilage. All patients underwent isovoxel 3D-VISTA and 3D-THRIVE MR sequences on 3T MRI. We assessed the cartilage grade on the two 3D sequences using arthroscopy as a gold standard. Inter-observer agreement for each technique was evaluated with the intraclass correlation coefficient (ICC). Differences in the area under the curve (AUC) were compared between the 3D-THRIVE and 3D-VISTA. Results Although inter-observer agreement for both sequences was excellent, the inter-observer agreement for 3D-VISTA was higher than for 3D-THRIVE for cartilage grading in all regions of the knee. There was no significant difference in the diagnostic performance ( P > 0.05) between the two sequences for detecting cartilage grade. Conclusion FSE-based 3D-VISTA images had good diagnostic performance that was comparable to GRE-based 3D-THRIVE images in the evaluation of knee cartilage, and can be used in routine knee MR protocols for the evaluation of cartilage.

  7. MRI Sequences in Head & Neck Radiology - State of the Art.

    PubMed

    Widmann, Gerlig; Henninger, Benjamin; Kremser, Christian; Jaschke, Werner

    2017-05-01

    Background  Magnetic resonance imaging (MRI) has become an essential imaging modality for the evaluation of head & neck pathologies. However, the diagnostic power of MRI is strongly related to the appropriate selection and interpretation of imaging protocols and sequences. The aim of this article is to review state-of-the-art sequences for the clinical routine in head & neck MRI and to describe the evidence for which medical question these sequences and techniques are useful. Method  Literature review of state-of-the-art sequences in head & neck MRI. Results and Conclusion  Basic sequences (T1w, T2w, T1wC+) and fat suppression techniques (TIRM/STIR, Dixon, Spectral Fat sat) are important tools in the diagnostic workup of inflammation, congenital lesions and tumors including staging. Additional sequences (SSFP (CISS, FIESTA), SPACE, VISTA, 3D-FLAIR) are used for pathologies of the cranial nerves, labyrinth and evaluation of endolymphatic hydrops in Menière's disease. Vessel and perfusion sequences (3D-TOF, TWIST/TRICKS angiography, DCE) are used in vascular contact syndromes, vascular malformations and analysis of microvascular parameters of tissue perfusion. Diffusion-weighted imaging (EPI-DWI, non-EPI-DWI, RESOLVE) is helpful in cholesteatoma imaging, estimation of malignancy, and evaluation of treatment response and posttreatment recurrence in head & neck cancer. Understanding of MRI sequences and close collaboration with referring physicians improves the diagnostic confidence of MRI in the daily routine and drives further research in this fascinating image modality. Key Points:   · Understanding of MRI sequences is essential for the correct and reliable interpretation of MRI findings.. · MRI protocols have to be carefully selected based on relevant clinical information.. · Close collaboration with referring physicians improves the output obtained from the diagnostic possibilities of MRI.. Citation Format · Widmann G, Henninger B, Kremser C et al. MRI Sequences in Head & Neck Radiology - State of the Art. Fortschr Röntgenstr 2017; 189: 413 - 422. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Power Tools for Talking: Custom Protocols Enrich Coaching Conversations

    ERIC Educational Resources Information Center

    Pomerantz, Francesca; Ippolito, Jacy

    2015-01-01

    Discussion-based protocols--an "agreed upon set of discussion or observation rules that guide coach/teacher/student work, discussion, and interactions" (Ippolito & Lieberman, 2012, p. 79)--can help focus and structure productive professional learning discussions. However, while protocols are slowly growing into essential elements of…

  9. Assessing and Managing Risk with Suicidal Individuals

    ERIC Educational Resources Information Center

    Linehan, Marsh M.; Comtois, Katherine A.; Ward-Ciesielski, Erin F.

    2012-01-01

    The University of Washington Risk Assessment Protocol (UWRAP) and Risk Assessment and Management Protocol (UWRAMP) have been used in numerous clinical trials treating high-risk suicidal individuals over several years. These protocols structure assessors and treatment providers to provide a thorough suicide risk assessment, review standards of care…

  10. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    PubMed

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-04-01

    To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p<0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the inclusion of DWI in the study protocol seems to be debatable. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. CT angiography of the aorta using 80 kVp in combination with sinogram-affirmed iterative reconstruction and automated tube current modulation: Effects on image quality and radiation dose.

    PubMed

    Boos, Johannes; Aissa, Joel; Lanzman, Rotem S; Heusch, Philipp; Schimmöller, Lars; Schleich, Christoph; Thomas, Christoph; Antoch, Gerald; Kröpil, Patric

    2016-04-01

    The objective of this study was to evaluate image quality and radiation dose of a CT angiography (CTA) protocol using 80 kVp in combination with iterative reconstruction and automated tube current modulation. Ninety-five aortic CTA examinations were included in this study. A novel 80 kVp aortic CTA-protocol with iterative reconstruction was introduced in our department in March 2012 for patients with a body mass index (BMI) below 32 kg/m(2). The first 72 consecutive examinations were retrospectively assigned to group A (56 patients, 42 men, 14 women, mean age 69.6 ± 10.7 years, BMI range 19.7-31.1 kg/m(2)). For comparison, the last 23 consecutive examinations performed with the old protocol (100 kVp) were assigned to group B (21 patients, 13 men, 8 women, mean age 67.4 ± 11.1 years, BMI range 19.7-31.9 kg/m(2)). Thoracic and abdominal contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and aortic attenuation were assessed. Subjective image quality was rated on a 5-point scale (1 = non diagnostic; 5 = excellent). Furthermore, dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were analysed. All examinations achieved diagnostic image quality. Attenuation of the aorta was significantly higher in group A compared with B (thoracic: 443.5 ± 90.5 Hounsfield units (HU) vs. 296.0 ± 61.0 HU; abdominal: 426.3 ± 94.2 HU vs. 283.6 ± 60.5 HU; P < 0.05, respectively). CNR, SNR and subjective image quality were comparable between both groups (CNR: 12.8 ± 3.7 vs. 13.0 ± 7.4; SNR 14.4 ± 3.9 vs. 14.9 ± 8.2; subjective image quality: 4.3 ± 0.6 vs. 4.5 ± 0.6; P > 0.05, respectively). CTDIvol and DLP were significantly lower in group A (1.9 ± 0.5 mGy; 139.2 ± 41.1 mGy × cm) as compared with group B (4.2 ± 1.4 mGy; 292.1 ± 91.5 mGy × cm; P < 0.001, respectively). Low-dose CTA of the aorta using 80 kVp with iterative reconstruction enables a significant dose reduction of up to 50% compared with a 100 kVp protocol in patients with a BMI below 32 kg/m(2) while diagnostic image quality is maintained. © 2016 The Royal Australian and New Zealand College of Radiologists.

  12. E-novo: an automated workflow for efficient structure-based lead optimization.

    PubMed

    Pearce, Bradley C; Langley, David R; Kang, Jia; Huang, Hongwei; Kulkarni, Amit

    2009-07-01

    An automated E-Novo protocol designed as a structure-based lead optimization tool was prepared through Pipeline Pilot with existing CHARMm components in Discovery Studio. A scaffold core having 3D binding coordinates of interest is generated from a ligand-bound protein structural model. Ligands of interest are generated from the scaffold using an R-group fragmentation/enumeration tool within E-Novo, with their cores aligned. The ligand side chains are conformationally sampled and are subjected to core-constrained protein docking, using a modified CHARMm-based CDOCKER method to generate top poses along with CDOCKER energies. In the final stage of E-Novo, a physics-based binding energy scoring function ranks the top ligand CDOCKER poses using a more accurate Molecular Mechanics-Generalized Born with Surface Area method. Correlation of the calculated ligand binding energies with experimental binding affinities were used to validate protocol performance. Inhibitors of Src tyrosine kinase, CDK2 kinase, beta-secretase, factor Xa, HIV protease, and thrombin were used to test the protocol using published ligand crystal structure data within reasonably defined binding sites. In-house Respiratory Syncytial Virus inhibitor data were used as a more challenging test set using a hand-built binding model. Least squares fits for all data sets suggested reasonable validation of the protocol within the context of observed ligand binding poses. The E-Novo protocol provides a convenient all-in-one structure-based design process for rapid assessment and scoring of lead optimization libraries.

  13. Current options for the treatment of facial angiofibromas.

    PubMed

    Salido-Vallejo, R; Garnacho-Saucedo, G; Moreno-Giménez, J C

    2014-01-01

    Facial angiofibromas are hamartomatous growths that are closely associated with tuberous sclerosis complex and, in fact, they constitute one of the main diagnostic criteria for that disease. These lesions composed of blood vessels and fibrous tissue appear on the face at an early age. Since they have important physical and psychological repercussions for patients, several treatment options have been used to remove them or improve their appearance. However, the lack of treatment guidelines prevents us from developing a common protocol for patients with this condition. The present article aims to review the treatments for facial angiofibromas used to date and to propose a new evidence-based treatment protocol. Copyright © 2012 Elsevier España, S.L. and AEDV. All rights reserved.

  14. PCR Amplification Strategies towards full-length HIV-1 Genome sequencing.

    PubMed

    Liu, Chao Chun; Ji, Hezhao

    2018-06-26

    The advent of next generation sequencing has enabled greater resolution of viral diversity and improved feasibility of full viral genome sequencing allowing routine HIV-1 full genome sequencing in both research and diagnostic settings. Regardless of the sequencing platform selected, successful PCR amplification of the HIV-1 genome is essential for sequencing template preparation. As such, full HIV-1 genome amplification is a crucial step in dictating the successful and reliable sequencing downstream. Here we reviewed existing PCR protocols leading to HIV-1 full genome sequencing. In addition to the discussion on basic considerations on relevant PCR design, the advantages as well as the pitfalls of published protocols were reviewed. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. [SCAN system--semi-structured interview based on diagnostic criteria].

    PubMed

    Adamowski, Tomasz; Kiejna, Andrzej; Hadryś, Tomasz

    2006-01-01

    This paper presents the main features of contemporary diagnostic systems which are implemented into the SCAN--modern and semi-structured diagnostic interview. The concepts of further development of the classifications, rationale for operationalized diagnostic criteria and for the divisional approach to mental diagnoses will be in focus. The structure and components of SCAN ver. 2.1 (WHO), i.e. Present State Examination--10th edition, Item Group Checklist, Clinical History Schedule, Glossary of Definitions and computer software with the diagnostic algorithm: I-Shell, as well as rules for a reliable use of diagnostic rating scales, will be discussed within the scope of this paper. The materials and training sets necessary for the learning of proper use of the SCAN, especially training sets for SCAN Training Centers and the Reference Manual--a form of guidebook for SCAN shall be introduced. Finally the paper will present evidence that SCAN is an instrument feasible in different cultural settings. Reliability and validity data of SCAN will also be dealt with indicating that SCAN could be widely used in research studies as well as in everyday clinical practice facilitating more detailed diagnostic approach to a patient.

  16. pH and salivary sodium bicarbonate during the administration protocol for methotrexate in children with leukemia.

    PubMed

    Rojas de Morales, Thais; Navas, Rita; Viera, Ninoska; Alvarez, Carmen Julia; Chaparro, Neira; Griman, Dariana

    2007-10-01

    To analyze the behavior of pH and sodium bicarbonate (NAHCO3) in the saliva of patients with leukemia during the administration protocol for Methotrexate (Mtx). A controlled clinical essay was carried out on 23 patients between 4 and 18 years of age with high-risk Acute Lymphoblastic Leukemia. Sampling was carried out at To: basal condition; T1: 12 hours after intravenous administration of sodium bicarbonate, before administering Mtx and T2: 3 hours after administering Mtx, the time of maximum concentration. Chiron-Diagnostic 378 equipment was used to determine pH and sodium bicarbonate. The data was interpreted using Analysis of Variance at the 5% significance level. The highest values of sodium bicarbonate were observed at T2, with salivary pH levels remaining within neutrality ranges, diminishing slightly in T1. CONCLUSION. In this study, the dose of sodium bicarbonate considered in the administration protocol of 3 g /m2 Mtx, kept sodium bicarbonate levels in saliva at normal levels and pH neutral.

  17. Tailoring protocols for chest CT applications: when and how?

    PubMed Central

    Iezzi, Roberto; Larici, Anna Rita; Franchi, Paola; Marano, Riccardo; Magarelli, Nicola; Posa, Alessandro; Merlino, Biagio; Manfredi, Riccardo; Colosimo, Cesare

    2017-01-01

    In the medical era of early detection of diseases and tailored therapies, an accurate characterization and staging of the disease is pivotal for treatment planning. The widespread use of computed tomography (CT)—often with the use of contrast material (CM)—probably represents the most important advance in diagnostic radiology. The result is a marked increase in radiation exposure of the population for medical purposes, with its intrinsic carcinogenic potential, and CM affecting kidney function. The radiologists should aim to minimize patient’s risk by reducing radiation exposure and CM amount, while maintaining the highest image quality. To achieve this goal, it is necessary to perform “patient-centric imaging”. The purpose of this review is to provide radiologists with “tips and tricks” to control radiation dose at CT, summarizing technical artifices in order to reduce image noise and increase image contrast. Also chest CT tailored protocols are supplied, with particular attention to three most common thoracic CT protocols: aortic/cardiac CT angiography (CTA), pulmonary CTA, and routine chest CT. PMID:29097345

  18. A Mobile Satellite Experiment (MSAT-X) network definition

    NASA Technical Reports Server (NTRS)

    Wang, Charles C.; Yan, Tsun-Yee

    1990-01-01

    The network architecture development of the Mobile Satellite Experiment (MSAT-X) project for the past few years is described. The results and findings of the network research activities carried out under the MSAT-X project are summarized. A framework is presented upon which the Mobile Satellite Systems (MSSs) operator can design a commercial network. A sample network configuration and its capability are also included under the projected scenario. The Communication Interconnection aspect of the MSAT-X network is discussed. In the MSAT-X network structure two basic protocols are presented: the channel access protocol, and the link connection protocol. The error-control techniques used in the MSAT-X project and the packet structure are also discussed. A description of two testbeds developed for experimentally simulating the channel access protocol and link control protocol, respectively, is presented. A sample network configuration and some future network activities of the MSAT-X project are also presented.

  19. Real-time echocardiogram transmission protocol based on regions and visualization modes.

    PubMed

    Cavero, Eva; Alesanco, Álvaro; García, José

    2014-09-01

    This paper proposes an Echocardiogram Transmission Protocol (ETP) for real-time end-to-end transmission of echocardiograms over IP networks. The ETP has been designed taking into account the echocardiogram characteristics of each visualized region, encoding each region according to its data type, visualization characteristics and diagnostic importance in order to improve the coding and thus the transmission efficiency. Furthermore, each region is sent separately and different error protection techniques can be used for each region. This leads to an efficient use of resources and provides greater protection for those regions with more clinical information. Synchronization is implemented for regions that change over time. The echocardiogram composition is different for each device. The protocol is valid for all echocardiogram devices thanks to the incorporation of configuration information which includes the composition of the echocardiogram. The efficiency of the ETP has been proved in terms of the number of bits sent with the proposed protocol. The codec and transmission rates used for the regions of interest have been set according to previous recommendations. Although the saving in the codified bits depends on the video composition, a coding gain higher than 7% with respect to without using ETP has been achieved.

  20. Novel multi-day sputum transport reagent works with routine tuberculosis tests and eliminates need for cold chain: Preliminary study of compatibility with the Xpert® MTB/RIF assay.

    PubMed

    Kelly-Cirino, Cassandra D; Curry, Patricia S; Marola, Jamie L; Helstrom, Niels K; Salfinger, Max

    2016-11-01

    OMNIgene®•SPUTUM (OM-S) is a sputum transport reagent designed to work with all tuberculosis diagnostics and eliminate the need for cold chain. The aim of this preliminary study was to assess the compatibility of OM-S-treated sputum with the Xpert® MTB/RIF assay. Fifty-five characterized sputa from the FIND TB Specimen Bank were used. Compatibility of OM-S was assessed for both Xpert sample preparation methods: H.1 protocol (sediment, n=25) and H.2 protocol (direct expectorate, n=30). All controls were prepared using the H.2 protocol. Results revealed 100% concordance of MTB/RIF results for all except the low-positive group in the H.1 study arm (n=10; 88% concordance). OM-S-treated sputa were successful in both protocols; if the Xpert buffer is not added during the H.2 procedure, sample viscosity may require repeat testing. Using OM-S could offer users flexibility in clinical testing algorithms. Larger compatibility studies are warranted, particularly with respect to MTB/RIF results for low-positive samples. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. [Cognitive therapy of trauma related guilt in patients with PTSD].

    PubMed

    Popiel, Agnieszka

    2014-01-01

    Various aspects of guilt are frequent problems of patients suffering from PTSD, though they have been included into the diagnostic criteria for PTSD just in the present version DSM-5. Some studies indicate limitation of effectiveness of exposure therapy in PTSD patients with predominant emotions of anger or guilt. The aim of this paper is to present cognitive conceptualization of guilt in PTSD proposed by Kubany, and a treatment protocol resulting from this conceptualization. The clinical application of the protocol is illustrated with preliminary results of systematic observation of 8 patients with moderate to severe PTSD who were treated with cognitive therapy for guilt followed by a standard prolonged exposure protocol. The cognitive therapy of guilt can be a valuable supplement for treatment of PTSD. This protocol can also be an inspiration for therapists working with patients with dysfunctional guilt as a problem in other than PTSD disorders--like depression or adjustment disorders. In discussion the place of guilt in treatment according to different (PE-Foa et al.; CPT-Resick et al.; CT-Ehlers and Clark) trauma focused therapy approaches is addressed, and the need for further studies is underlined.

  2. Defining Hand Stereotypies in Rett Syndrome: A Movement Disorders Perspective.

    PubMed

    Dy, Marisela E; Waugh, Jeff L; Sharma, Nutan; O'Leary, Heather; Kapur, Kush; D'Gama, Alissa M; Sahin, Mustafa; Urion, David K; Kaufmann, Walter E

    2017-10-01

    Hand stereotypies (HS) are a primary diagnostic criterion for Rett syndrome (RTT) but are difficult to characterize and quantify systematically. We collected video on 27 girls (2-12 years of age) with classic RTT who participated in a mecasermin trial. The present study focused exclusively on video analyses, by reviewing two five-minute windows per subject to identify the two most common HS. Three raters with expertise in movement disorders independently rated the five-minute windows using standardized terminology to determine the level of agreement. We iteratively refined the protocol in three stages to improve descriptive accuracy, categorizing HS as "central" or "peripheral," "simple" or "complex," scoring each hand separately. Inter-rater agreement was analyzed using Kappa statistics. In the initial protocol evaluating HS by video, inter-rater agreement was 20.7%. In the final protocol, inter-rater agreement for the two most frequent HS was higher than the initial protocol at 50%. Phenotypic variability makes standardized evaluation of HS in RTT a challenge; we achieved only 50% level of agreement and only for the most frequent HS. Therefore, objective measures are needed to evaluate HS. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Understanding the Latent Structure of the Emotional Disorders in Children and Adolescents

    ERIC Educational Resources Information Center

    Trosper, Sarah E.; Whitton, Sarah W.; Brown, Timothy A.; Pincus, Donna B.

    2012-01-01

    Investigators are persistently aiming to clarify structural relationships among the emotional disorders in efforts to improve diagnostic classification. The high co-occurrence of anxiety and mood disorders, however, has led investigators to portray the current structure of anxiety and depression in the "Diagnostic and Statistical Manual of Mental…

  4. An exploratory investigation of echocardiographic parameters and the effects of posture on cardiac structure and function in the Livingstone's fruit bat (Pteropus livingstonii).

    PubMed

    Drane, Aimee L; Shave, Robert; Routh, Andrew; Barbon, Alberto

    2018-01-01

    There is growing evidence that dilated cardiomyopathy may be a major cause of death in captive Livingstone's fruit bats (Pteropus livingstonii). Therefore, the primary aim of this prospective, exploratory study was to examine whether a systematic cardiac ultrasound protocol is feasible in this critically endangered species and to report basic measures of cardiac structure and function from a cohort of apparently healthy bats. A secondary aim was to test the effect posture (dorsal recumbency vs. roosting) has upon cardiac function in this species. Transthoracic echocardiograms, including 2D, Doppler, and tissue Doppler measures of cardiac structure and function were completed as part of routine health examinations for bats at a single center (n = 19). Bats were then grouped by age and disease status and the mean and range data reported for each group. In healthy adult bats, with the exception of a reduction in heart rate (P ≤ 0.05), right atrial systolic area (P ≤ 0.05), and right ventricular velocity during atrial contraction, there were no significant changes in cardiac structure or function in response to the roosting position. However, in the bats presenting with dilated cardiomyopathy the current data suggest that left ventricular ejection fraction is improved while roosting. Further work is required to confirm our initial findings, generate diagnostic reference intervals, and explore the causes of dilated cardiomyopathy in this species. © 2017 American College of Veterinary Radiology.

  5. Validity and Diagnostic Accuracy of Scores from the Autism Diagnostic Observation Schedule-Generic

    ERIC Educational Resources Information Center

    Reid, Melissa A.

    2012-01-01

    The purpose of this study was to examine the internal structure, relationships with other variables, and diagnostic accuracy of scores on the Autism Diagnostic Observation Schedule-Generic (ADOS-G; Lord et al., 1999) for the purpose of diagnostic decision-making. Participants were 462 children enrolled in a public school district in the southern…

  6. Cancer imaging phenomics toolkit: quantitative imaging analytics for precision diagnostics and predictive modeling of clinical outcome.

    PubMed

    Davatzikos, Christos; Rathore, Saima; Bakas, Spyridon; Pati, Sarthak; Bergman, Mark; Kalarot, Ratheesh; Sridharan, Patmaa; Gastounioti, Aimilia; Jahani, Nariman; Cohen, Eric; Akbari, Hamed; Tunc, Birkan; Doshi, Jimit; Parker, Drew; Hsieh, Michael; Sotiras, Aristeidis; Li, Hongming; Ou, Yangming; Doot, Robert K; Bilello, Michel; Fan, Yong; Shinohara, Russell T; Yushkevich, Paul; Verma, Ragini; Kontos, Despina

    2018-01-01

    The growth of multiparametric imaging protocols has paved the way for quantitative imaging phenotypes that predict treatment response and clinical outcome, reflect underlying cancer molecular characteristics and spatiotemporal heterogeneity, and can guide personalized treatment planning. This growth has underlined the need for efficient quantitative analytics to derive high-dimensional imaging signatures of diagnostic and predictive value in this emerging era of integrated precision diagnostics. This paper presents cancer imaging phenomics toolkit (CaPTk), a new and dynamically growing software platform for analysis of radiographic images of cancer, currently focusing on brain, breast, and lung cancer. CaPTk leverages the value of quantitative imaging analytics along with machine learning to derive phenotypic imaging signatures, based on two-level functionality. First, image analysis algorithms are used to extract comprehensive panels of diverse and complementary features, such as multiparametric intensity histogram distributions, texture, shape, kinetics, connectomics, and spatial patterns. At the second level, these quantitative imaging signatures are fed into multivariate machine learning models to produce diagnostic, prognostic, and predictive biomarkers. Results from clinical studies in three areas are shown: (i) computational neuro-oncology of brain gliomas for precision diagnostics, prediction of outcome, and treatment planning; (ii) prediction of treatment response for breast and lung cancer, and (iii) risk assessment for breast cancer.

  7. Severe oligohydramnios with intact membranes: an indication for diagnostic amnioinfusion.

    PubMed

    Pryde, P G; Hallak, M; Lauria, M R; Littman, L; Bottoms, S F; Johnson, M P; Evans, M I

    2000-01-01

    To quantify the improvement in ultrasonographic fetal imaging following diagnostic amnioinfusion for the indication of unexplained midtrimester oligohydramnios. Patients referred for unexplained midtrimester oligohydramnios were retrospectively reviewed. Videotapes of those undergoing diagnostic antenatal amnioinfusion were analyzed for quality of visualization of routinely imaged structures before and after the infusion procedure. The overall rate of adequate visualization of fetal structures improved from 50.98 to 76.79% (p < 0.0001). In fetuses having preinfusion-identified obstructive uropathy, there was improvement in identification of associated anomalies from 11.8 to 31.3%. Several authors have suggested that diagnostic amnioinfusion can facilitate fetal imaging and increase diagnostic precision in the setting of unexplained severe oligohydramnios. We have quantified the improvement in the rate of optimal visualization of fetal structures which likely translates, in experienced hands, into this observed improved diagnostic precision. Of particular importance is the improvement in appreciation of associated anomalies in cases of obstructive uropathy in which such findings may determine whether or not invasive fetal therapy is indicated. Copyright 2000 S. Karger AG, Basel.

  8. [Inter-rater reliability and validity of the OPD-CA axes structure and conflict].

    PubMed

    Benecke, Cord; Bock, Astrid; Wieser, Elke; Tschiesner, Reinhard; Lochmann, Martha; Küspert, Felicia; Schorn, Robert; Viertler, Bernhard; Steinmayr-Gensluckner, Maria

    2011-01-01

    The manual of the Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) is an instrument meanwhile widespread in the clinical practice to assess psychodynamic dimensions. Publications of inter-rater agreement and validity are still outstanding. This study assessed the interrater-reliability and validity for the axis structure and the axis conflict. 60 adolescents between 14 and 17 years, with and without psychic disorders, were diagnosed with the Operationalized Psychodynamic Diagnostics in childhood and adolescence (Arbeitskreis OPD-KJ, 2007) and SCID-II-interviews and questionnaires. A partial sample of 36 OPD-CA-interviews was the data basis for the assessment of inter-rater agreement. Calculations of validity for axis structure and axis conflict were made with the whole sample. Inter-rater agreement for the axis structure and the axis conflict showed good to very good weighted Kappa coefficients among the trained raters. Validity of the axis structure showed good results. The Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) allows a reliable diagnostic of axis structure and axis conflict, if the ratings are done on the basis of semistructured videotaped interviews by trained raters. The axis structure shows validity, while the results concerning the validity of the axis conflict remain unclear.

  9. Effective virtual screening protocol for CYP2C9 ligands using a screening site constructed from flurbiprofen and S-warfarin pockets

    NASA Astrophysics Data System (ADS)

    Polgár, Tímea; Menyhárd, Dóra K.; Keserű, György M.

    2007-09-01

    An effective virtual screening protocol was developed against an extended active site of CYP2C9, which was derived from X-ray structures complexed with flubiprofen and S-warfarin. Virtual screening has been effectively supported by our structure-based pharmacophore model. Importance of hot residues identified by mutation data and structural analysis was first estimated in an enrichment study. Key role of Arg108 and Phe114 in ligand binding was also underlined. Our screening protocol successfully identified 76% of known CYP2C9 ligands in the top 1% of the ranked database resulting 76-fold enrichment relative to random situation. Relevance of the protocol was further confirmed in selectivity studies, when 89% of CYP2C9 ligands were retrieved from a mixture of CYP2C9 and CYP2C8 ligands, while only 22% of CYP2C8 ligands were found applying the structure-based pharmacophore constraints. Moderate discrimination of CYP2C9 ligands from CYP2C18 and CYP2C19 ligands could also be achieved extending the application domain of our virtual screening protocol for the entire CYP2C family. Our findings further demonstrate the existence of an active site comprising of at least two binding pockets and strengthens the need of involvement of protein flexibility in virtual screening.

  10. A new rapid kindling variant for induction of cortical epileptogenesis in freely moving rats

    PubMed Central

    Morales, Juan Carlos; Álvarez-Ferradas, Carla; Roncagliolo, Manuel; Fuenzalida, Marco; Wellmann, Mario; Nualart, Francisco Javier; Bonansco, Christian

    2014-01-01

    Kindling, one of the most used models of experimental epilepsy is based on daily electrical stimulation in several brain structures. Unlike the classic or slow kindling protocols (SK), the rapid kindling types (RK) described until now require continuous stimulation at suprathreshold intensities applied directly to the same brain structure used for subsequent electrophysiological and immunohistochemical studies, usually the hippocampus. However, the cellular changes observed in these rapid protocols, such as astrogliosis and neuronal loss, could be due to experimental manipulation more than to epileptogenesis-related alterations. Here, we developed a new RK protocol in order to generate an improved model of temporal lobe epilepsy (TLE) which allows gradual progression of the epilepsy as well as obtaining an epileptic hippocampus, thus avoiding direct surgical manipulation and electric stimulation over this structure. This new protocol consists of basolateral amygdala (BLA) stimulation with 10 trains of biphasic pulses (10 s; 50 Hz) per day with 20 min-intervals, during 3 consecutive days, using a subconvulsive and subthreshold intensity, which guarantees tissue integrity. The progression of epileptic activity was evaluated in freely moving rats through electroencephalographic (EEG) recordings from cortex and amygdala, accompanied with synchronized video recordings. Moreover, we assessed the effectiveness of RK protocol and the establishment of epilepsy by evaluating cellular alterations of hippocampal slices from kindled rats. RK protocol induced convulsive states similar to SK protocols but in 3 days, with persistently lowered threshold to seizure induction and epileptogenic-dependent cellular changes in amygdala projection areas. We concluded that this novel RK protocol introduces a new variant of the chronic epileptogenesis models in freely moving rats, which is faster, highly reproducible and causes minimum cell damage with respect to that observed in other experimental models of epilepsy. PMID:25100948

  11. A new rapid kindling variant for induction of cortical epileptogenesis in freely moving rats.

    PubMed

    Morales, Juan Carlos; Alvarez-Ferradas, Carla; Roncagliolo, Manuel; Fuenzalida, Marco; Wellmann, Mario; Nualart, Francisco Javier; Bonansco, Christian

    2014-01-01

    Kindling, one of the most used models of experimental epilepsy is based on daily electrical stimulation in several brain structures. Unlike the classic or slow kindling protocols (SK), the rapid kindling types (RK) described until now require continuous stimulation at suprathreshold intensities applied directly to the same brain structure used for subsequent electrophysiological and immunohistochemical studies, usually the hippocampus. However, the cellular changes observed in these rapid protocols, such as astrogliosis and neuronal loss, could be due to experimental manipulation more than to epileptogenesis-related alterations. Here, we developed a new RK protocol in order to generate an improved model of temporal lobe epilepsy (TLE) which allows gradual progression of the epilepsy as well as obtaining an epileptic hippocampus, thus avoiding direct surgical manipulation and electric stimulation over this structure. This new protocol consists of basolateral amygdala (BLA) stimulation with 10 trains of biphasic pulses (10 s; 50 Hz) per day with 20 min-intervals, during 3 consecutive days, using a subconvulsive and subthreshold intensity, which guarantees tissue integrity. The progression of epileptic activity was evaluated in freely moving rats through electroencephalographic (EEG) recordings from cortex and amygdala, accompanied with synchronized video recordings. Moreover, we assessed the effectiveness of RK protocol and the establishment of epilepsy by evaluating cellular alterations of hippocampal slices from kindled rats. RK protocol induced convulsive states similar to SK protocols but in 3 days, with persistently lowered threshold to seizure induction and epileptogenic-dependent cellular changes in amygdala projection areas. We concluded that this novel RK protocol introduces a new variant of the chronic epileptogenesis models in freely moving rats, which is faster, highly reproducible and causes minimum cell damage with respect to that observed in other experimental models of epilepsy.

  12. Audit of HIV counselling and testing services among primary healthcare facilities in Cameroon: a protocol for a multicentre national cross-sectional study.

    PubMed

    Tianyi, Frank-Leonel; Tochie, Joel Noutakdie; Agbor, Valirie Ndip; Kadia, Benjamin Momo

    2018-03-01

    HIV testing is an invaluable entry point to prevention, care and treatment services for people living with HIV and AIDS. Poor adherence to recommended protocols and guidelines reduces the performance of rapid diagnostic tests, leading to misdiagnosis and poor estimation of HIV seroprevalence. This study seeks to evaluate the adherence of primary healthcare facilities in Cameroon to recommended HIV counselling and testing (HCT) procedures and the impact this may have on the reliability of HIV test results. This will be an analytical cross-sectional study involving primary healthcare facilities from all the 10 regions of Cameroon, selected by a multistaged random sampling of primary care facilities in each region. The study will last for 9 months. A structured questionnaire will be used to collect general information concerning the health facility, laboratory and other departments involved in the HCT process. The investigators will directly observe at least 10 HIV testing processes in each facility and fill out the checklist accordingly. Clearance has been obtained from the National Ethical Committee to carry out the study. Informed consent will be sought from the patients to observe the HIV testing process. The final study will be published in a peer-reviewed journal and the findings presented to health policy-makers and the general public. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Approach to the critically ill camelid.

    PubMed

    Bedenice, Daniela

    2009-07-01

    The estimation of fluid deficits in camelids is challenging. However, early recognition and treatment of shock and hypovolemia is instrumental to improve morbidity and mortality of critically ill camelids. Early goal-directed fluid therapy requires specific knowledge of clinical indicators of hypovolemia and assessment of resuscitation endpoints, but may significantly enhance the understanding, monitoring, and safety of intravenous fluid therapy in South American camelids (SAC). It is important to recognize that over-aggressive fluid resuscitation is just as detrimental as under resuscitation. Nonetheless, a protocol of conservative fluid management is often indicated in the treatment of camelids with pulmonary inflammation, to counteract edema formation. The early recognition of lung dysfunction is often based on advanced diagnostic techniques, including arterial blood gas analysis, diagnostic imaging, and noninvasive pulmonary function testing.

  14. A framework for solving ill-structured community problems

    NASA Astrophysics Data System (ADS)

    Keller, William Cotesworth

    A multifaceted protocol for solving ill-structured community problems has been developed. It embodies the lessons learned from the past by refining and extending features of previous models from the systems thinkers, and the fields of behavioral decision making and creative problem solving. The protocol also embraces additional features needed to address the unique aspects of community decision situations. The essential elements of the protocol are participants from the community, a problem-solving process, a systems picture, a facilitator, a modified Delphi method of communications, and technical expertise. This interdisciplinary framework has been tested by a quasi experiment with a real world community problem (the high cost of electrical power on Long Island, NY). Results indicate the protocol can enable members of the community to understand a complicated, ill-structured problem and guide them to action to solve the issue. However, the framework takes time (over one year in the test case) and will be inappropriate for crises where quick action is needed.

  15. Combination of interferometry and thermography data for cultural heritage structural diagnostic research

    NASA Astrophysics Data System (ADS)

    Tornari, Vivi; Andrianakis, Michalis; Hatzigiannakis, Kostas; Kosma, Kiki; Detalle, Vincent; Giovanacci, David

    2017-07-01

    The demand for non destructive and non invasive structural diagnostic techniques able to perform on field remote structural evaluation of historical structures and works of art it faces an increased demand. The techniques must have some basic important characteristics The non destructivity, accuracy, repeatability, non physical contact, portability, resolution, broad range of applicability depending on the type of artwork and the question at hand, are all among the important requirements underlying the requirement for on-field structural diagnostics. In this respect there are two known techniques that have been developed at full to provide a suited structural diagnostic application in artwork conservation. The systems presented here but discussed in detail elsewhere are stimulated infrared thermography (SIRT) and digital holographic speckle pattern interferometry (DHSPI) the prior can be found n market at commercial devise level while the latter is at laboratory prototype level. The two systems are being exploited for their complimentary advantages and in this paper are used in combined testing on art related targets according to the above criteria to confirm the enhanced diagnostic information that their complimentary use provides. Results confirm the effectiveness of each technique alone and the combination of data of both techniques in the conservation field. Each system is first briefly described and examples are given with the aim to present the suitability and appropriateness for use in structural documentation analysis and reports. The experimental work is in laboratory work-in-progress focusing on the hybriding of data synthesis.

  16. Development and implementation of clinical trial protocol templates at the National Institute of Allergy and Infectious Diseases.

    PubMed

    Bridge, Heather; Smolskis, Mary; Bianchine, Peter; Dixon, Dennis O; Kelly, Grace; Herpin, Betsey; Tavel, Jorge

    2009-08-01

    A clinical research protocol document must reflect both sound scientific rationale as well as local, national and, when applicable, international regulatory and human subject protections requirements. These requirements originate from a variety of sources, undergo frequent revision and are subject to interpretation. Tools to assist clinical investigators in the production of clinical protocols could facilitate navigating these requirements and ultimately increase the efficiency of clinical research. The National Institute of Allergy and Infectious Diseases (NIAID) developed templates for investigators to serve as the foundation for protocol development. These protocol templates are designed as tools to support investigators in developing clinical protocols. NIAID established a series of working groups to determine how to improve its capacity to conduct clinical research more efficiently and effectively. The Protocol Template Working Group was convened to determine what protocol templates currently existed within NIAID and whether standard NIAID protocol templates should be produced. After review and assessment of existing protocol documents and requirements, the group reached consensus about required and optional content, determined the format and identified methods for distribution as well as education of investigators in the use of these templates. The templates were approved by the NIAID Executive Committee in 2006 and posted as part of the NIAID Clinical Research Toolkit [1] website for broad access. These documents require scheduled revisions to stay current with regulatory and policy changes. The structure of any clinical protocol template, whether comprehensive or specific to a particular study phase, setting or design, affects how it is used by investigators. Each structure presents its own set of advantages and disadvantages. While useful, protocol templates are not stand-alone tools for creating an optimal protocol document, but must be complemented by institutional resources and support. Education and guidance of investigators in the appropriate use of templates is necessary to ensure a complete yet concise protocol document. Due to changing regulatory requirements, clinical protocol templates cannot become static, but require frequent revisions.

  17. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

  18. Impact of Diagnosticity on the Adequacy of Models for Cognitive Diagnosis under a Linear Attribute Structure: A Simulation Study

    ERIC Educational Resources Information Center

    de La Torre, Jimmy; Karelitz, Tzur M.

    2009-01-01

    Compared to unidimensional item response models (IRMs), cognitive diagnostic models (CDMs) based on latent classes represent examinees' knowledge and item requirements using discrete structures. This study systematically examines the viability of retrofitting CDMs to IRM-based data with a linear attribute structure. The study utilizes a procedure…

  19. Structural barriers in access to medical marijuana in the USA-a systematic review protocol.

    PubMed

    Valencia, Celina I; Asaolu, Ibitola O; Ehiri, John E; Rosales, Cecilia

    2017-08-07

    There are 43 state medical marijuana programs in the USA, yet limited evidence is available on the demographic characteristics of the patient population accessing these programs. Moreover, insights into the social and structural barriers that inform patients' success in accessing medical marijuana are limited. A current gap in the scientific literature exists regarding generalizable data on the social, cultural, and structural mechanisms that hinder access to medical marijuana among qualifying patients. The goal of this systematic review, therefore, is to identify the aforementioned mechanisms that inform disparities in access to medical marijuana in the USA. This scoping review protocol outlines the proposed study design for the systematic review and evaluation of peer-reviewed scientific literature on structural barriers to medical marijuana access. The protocol follows the guidelines set forth by the Preferred Reporting Items for Systematic review and Meta-Analysis Protocols (PRISMA-P) checklist. The overarching goal of this study is to rigorously evaluate the existing peer-reviewed data on access to medical marijuana in the USA. Income, ethnic background, stigma, and physician preferences have been posited as the primary structural barriers influencing medical marijuana patient population demographics in the USA. Identification of structural barriers to accessing medical marijuana provides a framework for future policies and programs. Evidence-based policies and programs for increasing medical marijuana access help minimize the disparity of access among qualifying patients.

  20. Pregnancy Research on Osteopathic Manipulation Optimizing Treatment Effects: The PROMOTE Study Protocol.

    PubMed

    Hensel, Kendi L; Carnes, Michael S; Stoll, Scott T

    2016-11-01

    The structural and physiologic changes in a woman's body during pregnancy can predispose pregnant women to low back pain and its associated disability, as well as to complications of pregnancy, labor, and delivery. Anecdotal and empirical evidence has indicated that osteopathic manipulative treatment (OMT) may be efficacious in improving pain and functionality in women who are pregnant. Based on that premise, the Pregnancy Research on Osteopathic Manipulation Optimizing Treatment Effects (PROMOTE) study was designed as a prospective, randomized, placebo-controlled, and blinded clinical trial to evaluate the efficacy of an OMT protocol for pain during third-trimester pregnancy. The OMT protocol developed for the PROMOTE study was based on physiologic theory and the concept of the interrelationship of structure and function. The 12 well-defined, standardized OMT techniques used in the protocol are commonly taught at osteopathic medical schools in the United States. These techniques can be easily replicated as a 20-minute protocol applied in conjunction with usual prenatal care, thus making it feasible to implement into clinical practice. This article presents an overview of the study design and treatment protocols used in the PROMOTE study.

Top