Sample records for study assessing reproducibility

  1. Quantification of atrial dynamics using cardiovascular magnetic resonance: inter-study reproducibility.

    PubMed

    Kowallick, Johannes T; Morton, Geraint; Lamata, Pablo; Jogiya, Roy; Kutty, Shelby; Hasenfuß, Gerd; Lotz, Joachim; Nagel, Eike; Chiribiri, Amedeo; Schuster, Andreas

    2015-05-17

    Cardiovascular magnetic resonance (CMR) offers quantification of phasic atrial functions based on volumetric assessment and more recently, on CMR feature tracking (CMR-FT) quantitative strain and strain rate (SR) deformation imaging. Inter-study reproducibility is a key requirement for longitudinal studies but has not been defined for CMR-based quantification of left atrial (LA) and right atrial (RA) dynamics. Long-axis 2- and 4-chamber cine images were acquired at 9:00 (Exam A), 9:30 (Exam B) and 14:00 (Exam C) in 16 healthy volunteers. LA and RA reservoir, conduit and contractile booster pump functions were quantified by volumetric indexes as derived from fractional volume changes and by strain and SR as derived from CMR-FT. Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation of atrial function. Inter-study reproducibility was within acceptable limits for all LA and RA volumetric, strain and SR parameters. Inter-study reproducibility was better for volumetric indexes and strain than for SR parameters and better for LA than for RA dynamics. For the LA, reservoir function showed the best reproducibility (intraclass correlation coefficient (ICC) 0.94-0.97, coefficient of variation (CoV) 4.5-8.2%), followed by conduit (ICC 0.78-0.97, CoV 8.2-18.5%) and booster pump function (ICC 0.71-0.95, CoV 18.3-22.7). Similarly, for the RA, reproducibility was best for reservoir function (ICC 0.76-0.96, CoV 7.5-24.0%) followed by conduit (ICC 0.67-0.91, CoV 13.9-35.9) and booster pump function (ICC 0.73-0.90, CoV 19.4-32.3). Atrial dynamics were not measurably affected by diurnal variation between morning and afternoon scans. Inter-study reproducibility for CMR-based derivation of LA and RA functions is acceptable using either volumetric, strain or SR parameters with LA function showing higher reproducibility than RA function assessment. Amongst the different functional components, reservoir function is most reproducibly assessed by either technique followed by conduit and booster pump function, which needs to be considered in future longitudinal research studies.

  2. The Dutch motor skills assessment as tool for talent development in table tennis: a reproducibility and validity study.

    PubMed

    Faber, Irene R; Nijhuis-Van Der Sanden, Maria W G; Elferink-Gemser, Marije T; Oosterveld, Frits G J

    2015-01-01

    A motor skills assessment could be helpful in talent development by estimating essential perceptuo-motor skills of young players, which are considered requisite to develop excellent technical and tactical qualities. The Netherlands Table Tennis Association uses a motor skills assessment in their talent development programme consisting of eight items measuring perceptuo-motor skills specific to table tennis under varying conditions. This study aimed to investigate this assessment regarding its reproducibility, internal consistency, underlying dimensions and concurrent validity in 113 young table tennis players (6-10 years). Intraclass correlation coefficients of six test items met the criteria of 0.7 with coefficients of variation between 3% and 8%. Cronbach's alpha valued 0.853 for internal consistency. The principal components analysis distinguished two conceptually meaningful factors: "ball control" and "gross motor function." Concurrent validity analyses demonstrated moderate associations between the motor skills assessment's results and national ranking; boys r = -0.53 (P < 0.001) and girls r = -0.45 (P = 0.015). In conclusion, this evaluation demonstrated six test items with acceptable reproducibility, good internal consistency and good prospects for validity. Two test items need revision to upgrade reproducibility. Since the motor skills assessment seems to be a reproducible, objective part of a talent development programme, more longitudinal studies are required to investigate its predictive validity.

  3. Development of a stain shade guide to aid the measurement of extrinsic dental stain.

    PubMed

    Gadhia, K; Shah, R; Swaminathan, D; Wetton, S; Moran, J

    2006-05-01

    Accurate and reproducible assessment of extrinsic staining is pivotal to determining efficacy of some tooth whitening oral hygiene products. The aim of this study was: (1) to produce a stain shade guide to aid the in vitro and in vivo stain assessment (2) to assess intra- and inter-examiner reproducibility of stain assessment using the stain shade guide. Using chlorhexidine and tea, perspex and acrylic teeth specimens were stained. The amount of staining on the perspex was measured with a spectrophotometer and the values obtained were assigned to the stained acrylic teeth, which were made into a stain guide. Using clinical photographs and a group of 10 volunteers, stain area and intensity were assessed using the stain guide and the recognized Lobene stain index by two examiners. The degree of intra- and inter-examiner reproducibility for these measurements were assessed using Cohen's kappa statistics. For both the clinical examination and use of photographs, intra-examiner reproducibility for stain intensity was improved when using the stain guide compared with the Lobene Index. Similarly, when assessing inter-examiner reproducibility, stain intensity kappa values were greater using the stain guide (kappa = 0.82) compared with the Lobene Index (kappa = 0.57). The findings of this study would suggest that the use of the stain guide could be of importance in the assessment of extrinsic dental stain.

  4. Response to Comment on "Estimating the reproducibility of psychological science".

    PubMed

    Anderson, Christopher J; Bahník, Štěpán; Barnett-Cowan, Michael; Bosco, Frank A; Chandler, Jesse; Chartier, Christopher R; Cheung, Felix; Christopherson, Cody D; Cordes, Andreas; Cremata, Edward J; Della Penna, Nicolas; Estel, Vivien; Fedor, Anna; Fitneva, Stanka A; Frank, Michael C; Grange, James A; Hartshorne, Joshua K; Hasselman, Fred; Henninger, Felix; van der Hulst, Marije; Jonas, Kai J; Lai, Calvin K; Levitan, Carmel A; Miller, Jeremy K; Moore, Katherine S; Meixner, Johannes M; Munafò, Marcus R; Neijenhuijs, Koen I; Nilsonne, Gustav; Nosek, Brian A; Plessow, Franziska; Prenoveau, Jason M; Ricker, Ashley A; Schmidt, Kathleen; Spies, Jeffrey R; Stieger, Stefan; Strohminger, Nina; Sullivan, Gavin B; van Aert, Robbie C M; van Assen, Marcel A L M; Vanpaemel, Wolf; Vianello, Michelangelo; Voracek, Martin; Zuni, Kellylynn

    2016-03-04

    Gilbert et al. conclude that evidence from the Open Science Collaboration's Reproducibility Project: Psychology indicates high reproducibility, given the study methodology. Their very optimistic assessment is limited by statistical misconceptions and by causal inferences from selectively interpreted, correlational data. Using the Reproducibility Project: Psychology data, both optimistic and pessimistic conclusions about reproducibility are possible, and neither are yet warranted. Copyright © 2016, American Association for the Advancement of Science.

  5. Assessing the accuracy and reproducibility of modality independent elastography in a murine model of breast cancer

    PubMed Central

    Weis, Jared A.; Flint, Katelyn M.; Sanchez, Violeta; Yankeelov, Thomas E.; Miga, Michael I.

    2015-01-01

    Abstract. Cancer progression has been linked to mechanics. Therefore, there has been recent interest in developing noninvasive imaging tools for cancer assessment that are sensitive to changes in tissue mechanical properties. We have developed one such method, modality independent elastography (MIE), that estimates the relative elastic properties of tissue by fitting anatomical image volumes acquired before and after the application of compression to biomechanical models. The aim of this study was to assess the accuracy and reproducibility of the method using phantoms and a murine breast cancer model. Magnetic resonance imaging data were acquired, and the MIE method was used to estimate relative volumetric stiffness. Accuracy was assessed using phantom data by comparing to gold-standard mechanical testing of elasticity ratios. Validation error was <12%. Reproducibility analysis was performed on animal data, and within-subject coefficients of variation ranged from 2 to 13% at the bulk level and 32% at the voxel level. To our knowledge, this is the first study to assess the reproducibility of an elasticity imaging metric in a preclinical cancer model. Our results suggest that the MIE method can reproducibly generate accurate estimates of the relative mechanical stiffness and provide guidance on the degree of change needed in order to declare biological changes rather than experimental error in future therapeutic studies. PMID:26158120

  6. Inter-study reproducibility of left ventricular torsion and torsion rate quantification using MR myocardial feature tracking.

    PubMed

    Kowallick, Johannes T; Morton, Geraint; Lamata, Pablo; Jogiya, Roy; Kutty, Shelby; Lotz, Joachim; Hasenfuß, Gerd; Nagel, Eike; Chiribiri, Amedeo; Schuster, Andreas

    2016-01-01

    To determine the inter-study reproducibility of MR feature tracking (MR-FT) derived left ventricular (LV) torsion and torsion rates for a combined assessment of systolic and diastolic myocardial function. Steady-state free precession (SSFP) cine LV short-axis stacks were acquired at 9:00 (Exam A), 9:30 (Exam B), and 14:00 (Exam C) in 16 healthy volunteers at 3 Tesla. SSFP images were analyzed offline using MR-FT to assess rotational displacement in apical and basal slices. Global peak torsion, peak systolic and peak diastolic torsion rates were calculated using different definitions ("twist", "normalized twist" and "circumferential-longitudinal (CL) shear angle"). Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation. The different methods showed good inter-study reproducibility for global peak torsion (intraclass correlation coefficient [ICC]: 0.90-0.92; coefficient of variation [CoV]: 19.0-20.3%) and global peak systolic torsion rate (ICC: 0.82-0.84; CoV: 25.9-29.0%). Conversely, global peak diastolic torsion rate showed little inter-study reproducibility (ICC: 0.34-0.47; CoV: 40.8-45.5%). Global peak torsion as determined by the CL shear angle showed the best inter-study reproducibility (ICC: 0.90;CoV: 19.0%). MR-FT results were not measurably affected by diurnal variation between morning and afternoon scans (CL shear angle: 4.8 ± 1.4°, 4.8 ± 1.5°, and 4.1 ± 1.6° for Exam A, B, and C, respectively; P = 0.21). MR-FT based derivation of myocardial peak torsion and peak systolic torsion rate has high inter-study reproducibility as opposed to peak diastolic torsion rate. The CL shear angle was the most reproducible parameter independently of cardiac anatomy and may develop into a robust tool to quantify cardiac rotational mechanics in longitudinal MR-FT patient studies. © 2015 Wiley Periodicals, Inc.

  7. Validity and reproducibility of electrical impedance tomography for measurement of calf blood flow in healthy subjects.

    PubMed

    Vonk Noordegraaf, A; Kunst, P W; Janse, A; Smulders, R A; Heethaar, R M; Postmus, P E; Faes, T J; de Vries, P M

    1997-03-01

    The Sheffield electrical impedance tomography; (EIT) system produces images of changes in the distribution of resistivity within tissue. The paper reports on the application of electrical impedance tomography in monitoring volume changes in the limb during venous occlusion. The aim of the study is to assess the feasibility, reproducibility and validity of calf blood flow measurements by EIT. In 14 healthy volunteers calf blood flow is compared, as determined in a calf segment by strain-gauge plethysmography (SGP), with the impedance changes measured by EIT during rest and post-ischaemic hyperaemia. The measurements are repeated to assess reproducibility. The reproducibility for the EIT, assessed from the repeated measurements and expressed as a reproducibility coefficient, is 0.88 during rest and 0.89 during hyperaemia. The reproducibility coefficient for SGP data is 0.83 at rest and 0.67 during hyperaemia. Flow measurements, assessed by means of two methods, correlate well at rest (r = 0.89), but only moderately during hyperaemia (r = 0.51). The correlation coefficient for the pooled flow measurements is 0.98. It is concluded that EIT is a valid and reliable method for assessing blood flow in the limb. Possible applications of EIT in localising fluid changes are discussed.

  8. Quality Control and Reproducibility in M-mode, Two-dimensional, and Speckle Tracking Echocardiography Acquisition and Analysis: The CARDIA Study, Year-25 Examination Experience

    PubMed Central

    Armstrong, Anderson C.; Ricketts, Erin P.; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; RDCS; Sidney, Stephen; Lewis, Cora E.; Schreiner, Pamela J.; Shikany, James M.; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S.; Lima, João A. C.

    2014-01-01

    Introduction Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultra-sound, particularly in novel techniques such as Speckle Tracking (STE). We evaluate the echocardiography assessment performance in the CARDIA study Y25 examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and Reading Center (RC) accuracy. Methods The CARDIA Y25 examination had 3,475 echocardiograms performed in 4 US Field Centers and analyzed in a Reading Center, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (2- and 4-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intra-class correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. Results For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and 4-chamber and 58% in 2-chamber. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with Echo RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Conclusion Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. PMID:25382818

  9. Quality Control and Reproducibility in M-Mode, Two-Dimensional, and Speckle Tracking Echocardiography Acquisition and Analysis: The CARDIA Study, Year 25 Examination Experience.

    PubMed

    Armstrong, Anderson C; Ricketts, Erin P; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; Sidney, Stephen; Lewis, Cora E; Schreiner, Pamela J; Shikany, James M; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S; Lima, João A C

    2015-08-01

    Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy. The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. © 2014, Wiley Periodicals, Inc.

  10. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    PubMed

    Grams, Samantha Torres; Kimoto, Karen Yumi Mota; Azevedo, Elen Moda de Oliveira; Lança, Marina; Albuquerque, André Luis Pereira de; Brito, Christina May Moran de; Yamaguti, Wellington Pereira

    2015-01-01

    Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. This study aimed to compare the MIP values assessed by standard method (MIPsta) and by unidirectional expiratory valve method (MIPuni) in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated. This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1]) was used to determine intraobserver and interobserver reproducibility. The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O) than the mean values for MIPsta (-102.5 ± 23.9 cmH2O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91), and high correlation for Test 2 (ICC[2,1] = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86) and evaluator B (ICC[2,1] = 0.77). MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  11. Reproducibility of Single-Pulse, Paired-Pulse, and Intermittent Theta-Burst TMS Measures in Healthy Aging, Type-2 Diabetes, and Alzheimer’s Disease

    PubMed Central

    Fried, Peter J.; Jannati, Ali; Davila-Pérez, Paula; Pascual-Leone, Alvaro

    2017-01-01

    Background: Transcranial magnetic stimulation (TMS) can be used to assess neurophysiology and the mechanisms of cortical brain plasticity in humans in vivo. As the use of these measures in specific populations (e.g., Alzheimer’s disease; AD) increases, it is critical to understand their reproducibility (i.e., test–retest reliability) in the populations of interest. Objective: Reproducibility of TMS measures was evaluated in older adults, including healthy, AD, and Type-2 diabetes mellitus (T2DM) groups. Methods: Participants received two identical neurophysiological assessments within a year including motor thresholds, baseline motor evoked potentials (MEPs), short- and long-interval intracortical inhibition (SICI, LICI) and intracortical facilitation (ICF), and MEP changes following intermittent theta-burst stimulation (iTBS). Cronbach’s α coefficients were calculated to assess reproducibility. Multiple linear regression analyses were used to investigate factors related to intraindividual variability. Results: Reproducibility was highest for motor thresholds, followed by baseline MEPs, SICI and LICI, and was lowest for ICF and iTBS aftereffects. The AD group tended to show higher reproducibility than T2DM or controls. Intraindividual variability of baseline MEPs was related to age and variability of RMT, while the intraindividual variability in post-iTBS measures was related to baseline MEP variability, intervisit duration, and Brain-derived neurotrophic factor (BDNF) polymorphism. Conclusion: Increased reproducibility in AD may reflect pathophysiological declines in the efficacy of neuroplastic mechanisms. Reproducibility of iTBS aftereffects can be improved by keeping baseline MEPs consistent, controlling for BDNF genotype, and waiting at least a week between visits. Significance: These findings provide the first direct assessment of reproducibility of TMS measures in older clinical populations. Reproducibility coefficients may be used to adjust effect- and sample size calculations for future studies. PMID:28871222

  12. The validity and reproducibility of food-frequency questionnaire-based total antioxidant capacity estimates in Swedish women.

    PubMed

    Rautiainen, Susanne; Serafini, Mauro; Morgenstern, Ralf; Prior, Ronald L; Wolk, Alicja

    2008-05-01

    Total antioxidant capacity (TAC) provides an assessment of antioxidant activity and synergistic interactions of redox molecules in foods and plasma. We investigated the validity and reproducibility of food-frequency questionnaire (FFQ)-based TAC estimates assessed by oxygen radical absorbance capacity (ORAC), total radical-trapping antioxidant parameters (TRAP), and ferric-reducing antioxidant power (FRAP) food values. Validity and reproducibility were evaluated in 2 random samples from the Swedish Mammography Cohort. Validity was studied by comparing FFQ-based TAC estimates with one measurement of plasma TAC in 108 women (54-73-y-old dietary supplement nonusers). Reproducibility was studied in 300 women (56-75 y old, 50.7% dietary supplement nonusers) who completed 2 FFQs 1 y apart. Fruit and vegetables (mainly apples, pears, oranges, and berries) were the major contributors to FFQ-based ORAC (56.5%), TRAP (41.7%), and FRAP (38.0%) estimates. In the validity study, whole plasma ORAC was correlated (Pearson) with FFQ-based ORAC (r = 0.35), TRAP (r = 0.31), and FRAP (r = 0.28) estimates from fruit and vegetables. Correlations between lipophilic plasma ORAC and FFQ-based ORAC, TRAP, and FRAP estimates from fruit and vegetables were 0.41, 0.31, and 0.28, and correlations with plasma TRAP estimates were 0.31, 0.30, and 0.28, respectively. Hydrophilic plasma ORAC and plasma FRAP values did not correlate with FFQ-based TAC estimates. Reproducibility, assessed by intraclass correlations, was 0.60, 0.61, and 0.61 for FFQ-based ORAC, TRAP, and FRAP estimates, respectively, from fruit and vegetables. FFQ-based TAC values represent valid and reproducible estimates that may be used in nutritional epidemiology to assess antioxidant intake from foods. Further studies in other populations to confirm these results are needed.

  13. Field assessment of balance in 10 to 14 year old children, reproducibility and validity of the Nintendo Wii board.

    PubMed

    Larsen, Lisbeth Runge; Jørgensen, Martin Grønbech; Junge, Tina; Juul-Kristensen, Birgit; Wedderkopp, Niels

    2014-06-10

    Because body proportions in childhood are different to those in adulthood, children have a relatively higher centre of mass location. This biomechanical difference and the fact that children's movements have not yet fully matured result in different sway performances in children and adults. When assessing static balance, it is essential to use objective, sensitive tools, and these types of measurement have previously been performed in laboratory settings. However, the emergence of technologies like the Nintendo Wii Board (NWB) might allow balance assessment in field settings. As the NWB has only been validated and tested for reproducibility in adults, the purpose of this study was to examine reproducibility and validity of the NWB in a field setting, in a population of children. Fifty-four 10-14 year-olds from the CHAMPS-Study DK performed four different balance tests: bilateral stance with eyes open (1), unilateral stance on dominant (2) and non-dominant leg (3) with eyes open, and bilateral stance with eyes closed (4). Three rounds of the four tests were completed with the NWB and with a force platform (AMTI). To assess reproducibility, an intra-day test-retest design was applied with a two-hour break between sessions. Bland-Altman plots supplemented by Minimum Detectable Change (MDC) and concordance correlation coefficient (CCC) demonstrated satisfactory reproducibility for the NWB and the AMTI (MDC: 26.3-28.2%, CCC: 0.76-0.86) using Centre Of Pressure path Length as measurement parameter. Bland-Altman plots demonstrated satisfactory concurrent validity between the NWB and the AMTI, supplemented by satisfactory CCC in all tests (CCC: 0.74-0.87). The ranges of the limits of agreement in the validity study were comparable to the limits of agreement of the reproducibility study. Both NWB and AMTI have satisfactory reproducibility for testing static balance in a population of children. Concurrent validity of NWB compared with AMTI was satisfactory. Furthermore, the results from the concurrent validity study were comparable to the reproducibility results of the NWB and the AMTI. Thus, NWB has the potential to replace the AMTI in field settings in studies including children. Future studies are needed to examine intra-subject variability and to test the predictive validity of NWB.

  14. Field assessment of balance in 10 to 14 year old children, reproducibility and validity of the Nintendo Wii board

    PubMed Central

    2014-01-01

    Background Because body proportions in childhood are different to those in adulthood, children have a relatively higher centre of mass location. This biomechanical difference and the fact that children’s movements have not yet fully matured result in different sway performances in children and adults. When assessing static balance, it is essential to use objective, sensitive tools, and these types of measurement have previously been performed in laboratory settings. However, the emergence of technologies like the Nintendo Wii Board (NWB) might allow balance assessment in field settings. As the NWB has only been validated and tested for reproducibility in adults, the purpose of this study was to examine reproducibility and validity of the NWB in a field setting, in a population of children. Methods Fifty-four 10–14 year-olds from the CHAMPS-Study DK performed four different balance tests: bilateral stance with eyes open (1), unilateral stance on dominant (2) and non-dominant leg (3) with eyes open, and bilateral stance with eyes closed (4). Three rounds of the four tests were completed with the NWB and with a force platform (AMTI). To assess reproducibility, an intra-day test-retest design was applied with a two-hour break between sessions. Results Bland-Altman plots supplemented by Minimum Detectable Change (MDC) and concordance correlation coefficient (CCC) demonstrated satisfactory reproducibility for the NWB and the AMTI (MDC: 26.3-28.2%, CCC: 0.76-0.86) using Centre Of Pressure path Length as measurement parameter. Bland-Altman plots demonstrated satisfactory concurrent validity between the NWB and the AMTI, supplemented by satisfactory CCC in all tests (CCC: 0.74-0.87). The ranges of the limits of agreement in the validity study were comparable to the limits of agreement of the reproducibility study. Conclusion Both NWB and AMTI have satisfactory reproducibility for testing static balance in a population of children. Concurrent validity of NWB compared with AMTI was satisfactory. Furthermore, the results from the concurrent validity study were comparable to the reproducibility results of the NWB and the AMTI. Thus, NWB has the potential to replace the AMTI in field settings in studies including children. Future studies are needed to examine intra-subject variability and to test the predictive validity of NWB. PMID:24913461

  15. Reproducibility of studies on text mining for citation screening in systematic reviews: Evaluation and checklist.

    PubMed

    Olorisade, Babatunde Kazeem; Brereton, Pearl; Andras, Peter

    2017-09-01

    Independent validation of published scientific results through study replication is a pre-condition for accepting the validity of such results. In computation research, full replication is often unrealistic for independent results validation, therefore, study reproduction has been justified as the minimum acceptable standard to evaluate the validity of scientific claims. The application of text mining techniques to citation screening in the context of systematic literature reviews is a relatively young and growing computational field with high relevance for software engineering, medical research and other fields. However, there is little work so far on reproduction studies in the field. In this paper, we investigate the reproducibility of studies in this area based on information contained in published articles and we propose reporting guidelines that could improve reproducibility. The study was approached in two ways. Initially we attempted to reproduce results from six studies, which were based on the same raw dataset. Then, based on this experience, we identified steps considered essential to successful reproduction of text mining experiments and characterized them to measure how reproducible is a study given the information provided on these steps. 33 articles were systematically assessed for reproducibility using this approach. Our work revealed that it is currently difficult if not impossible to independently reproduce the results published in any of the studies investigated. The lack of information about the datasets used limits reproducibility of about 80% of the studies assessed. Also, information about the machine learning algorithms is inadequate in about 27% of the papers. On the plus side, the third party software tools used are mostly free and available. The reproducibility potential of most of the studies can be significantly improved if more attention is paid to information provided on the datasets used, how they were partitioned and utilized, and how any randomization was controlled. We introduce a checklist of information that needs to be provided in order to ensure that a published study can be reproduced. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Reproducibility of dynamically represented acoustic lung images from healthy individuals

    PubMed Central

    Maher, T M; Gat, M; Allen, D; Devaraj, A; Wells, A U; Geddes, D M

    2008-01-01

    Background and aim: Acoustic lung imaging offers a unique method for visualising the lung. This study was designed to demonstrate reproducibility of acoustic lung images recorded from healthy individuals at different time points and to assess intra- and inter-rater agreement in the assessment of dynamically represented acoustic lung images. Methods: Recordings from 29 healthy volunteers were made on three separate occasions using vibration response imaging. Reproducibility was measured using quantitative, computerised assessment of vibration energy. Dynamically represented acoustic lung images were scored by six blinded raters. Results: Quantitative measurement of acoustic recordings was highly reproducible with an intraclass correlation score of 0.86 (very good agreement). Intraclass correlations for inter-rater agreement and reproducibility were 0.61 (good agreement) and 0.86 (very good agreement), respectively. There was no significant difference found between the six raters at any time point. Raters ranged from 88% to 95% in their ability to identically evaluate the different features of the same image presented to them blinded on two separate occasions. Conclusion: Acoustic lung imaging is reproducible in healthy individuals. Graphic representation of lung images can be interpreted with a high degree of accuracy by the same and by different reviewers. PMID:18024534

  17. [Inter-rater agreement on self-reported exposure to ergonomic risk factors for the upper extremities among mechanic assemblers in an automotive industry].

    PubMed

    d'Errico, Angelo; Fontana, Dario; Merogno, Angela

    2016-01-01

    to assess reproducibility of self-reported exposure to ergonomic hazards for the upper limbs, measured through a questionnaire based on a diffused checklist for the assessment of ergonomic risk (OCRA) in a sample of mechanical assemblers of an automotive industry. cross-sectional study; reproducibility was assessed as interrater agreement of a composite index of ergonomic risk, estimated through the intraclass correlation coefficient (ICC). 58 mechanical assemblers, working in 29 twin areas, characterised by same work stations and tasks. composite index of ergonomic risk for the upper limbs. reproducibility of the ergonomic index was high in the overall sample (ICC: 0.81) and it was higher for the twin areas employing same-gender workers (ICC: 0.96), compared to those with workers of the opposite gender (ICC: 0.66). these results indicate that a questionnaire measuring with a great detail the exposure to the main ergonomic risk factors for the upper limbs, as the one based on the OCRA checklist used for this study, would allow to obtain a highly reproducible ergonomic index. If its validity against the corresponding observational checklist will be found elevated by future studies, this questionnaire may represent a useful tool for a preliminary assessment of workers' exposure to ergonomic hazards for the upper limbs.

  18. HiCRep: assessing the reproducibility of Hi-C data using a stratum-adjusted correlation coefficient

    PubMed Central

    Yang, Tao; Zhang, Feipeng; Yardımcı, Galip Gürkan; Song, Fan; Hardison, Ross C.; Noble, William Stafford; Yue, Feng; Li, Qunhua

    2017-01-01

    Hi-C is a powerful technology for studying genome-wide chromatin interactions. However, current methods for assessing Hi-C data reproducibility can produce misleading results because they ignore spatial features in Hi-C data, such as domain structure and distance dependence. We present HiCRep, a framework for assessing the reproducibility of Hi-C data that systematically accounts for these features. In particular, we introduce a novel similarity measure, the stratum adjusted correlation coefficient (SCC), for quantifying the similarity between Hi-C interaction matrices. Not only does it provide a statistically sound and reliable evaluation of reproducibility, SCC can also be used to quantify differences between Hi-C contact matrices and to determine the optimal sequencing depth for a desired resolution. The measure consistently shows higher accuracy than existing approaches in distinguishing subtle differences in reproducibility and depicting interrelationships of cell lineages. The proposed measure is straightforward to interpret and easy to compute, making it well-suited for providing standardized, interpretable, automatable, and scalable quality control. The freely available R package HiCRep implements our approach. PMID:28855260

  19. Reproducibility of food consumption frequencies derived from the Children's Eating Habits Questionnaire used in the IDEFICS study.

    PubMed

    Lanfer, A; Hebestreit, A; Ahrens, W; Krogh, V; Sieri, S; Lissner, L; Eiben, G; Siani, A; Huybrechts, I; Loit, H-M; Papoutsou, S; Kovács, E; Pala, V

    2011-04-01

    To investigate the reproducibility of food consumption frequencies derived from the food frequency section of the Children's Eating Habits Questionnaire (CEHQ-FFQ) that was developed and used in the IDEFICS (Identification and prevention of dietary- and lifestyle-induced health effects in children and infants) project to assess food habits in 2- to 9-year-old European children. From a subsample of 258 children who participated in the IDEFICS baseline examination, parental questionnaires of the CEHQ were collected twice to assess reproducibility of questionnaire results from 0 to 354 days after the first examination. Weighted Cohen's kappa coefficients (κ) and Spearman's correlation coefficients (r) were calculated to assess agreement between the first and second questionnaires for each food item of the CEHQ-FFQ. Stratification was performed for sex, age group, geographical region and length of period between the first and second administrations. Fisher's Z transformation was applied to test correlation coefficients for significant differences between strata. For all food items analysed, weighted Cohen's kappa coefficients (κ) and Spearman's correlation coefficients (r) were significant and positive (P<0.001). Reproducibility was lowest for diet soft drinks (κ=0.23, r=0.32) and highest for sweetened milk (κ=0.68, r=0.76). Correlation coefficients were comparable to those of previous studies on FFQ reproducibility in children and adults. Stratification did not reveal systematic differences in reproducibility by sex and age group. Spearman's correlation coefficients differed significantly between northern and southern European countries for 10 food items. In nine of them, the lower respective coefficient was still high enough to conclude acceptable reproducibility. As expected, longer time (>128 days) between the first and second administrations resulted in a generally lower, yet still acceptable, reproducibility. Results indicate that the CEHQ-FFQ gives reproducible estimates of the consumption frequency of 43 food items from 14 food groups in European children.

  20. Reproducibility of the dynamics of facial expressions in unilateral facial palsy.

    PubMed

    Alagha, M A; Ju, X; Morley, S; Ayoub, A

    2018-02-01

    The aim of this study was to assess the reproducibility of non-verbal facial expressions in unilateral facial paralysis using dynamic four-dimensional (4D) imaging. The Di4D system was used to record five facial expressions of 20 adult patients. The system captured 60 three-dimensional (3D) images per second; each facial expression took 3-4seconds which was recorded in real time. Thus a set of 180 3D facial images was generated for each expression. The procedure was repeated after 30min to assess the reproducibility of the expressions. A mathematical facial mesh consisting of thousands of quasi-point 'vertices' was conformed to the face in order to determine the morphological characteristics in a comprehensive manner. The vertices were tracked throughout the sequence of the 180 images. Five key 3D facial frames from each sequence of images were analyzed. Comparisons were made between the first and second capture of each facial expression to assess the reproducibility of facial movements. Corresponding images were aligned using partial Procrustes analysis, and the root mean square distance between them was calculated and analyzed statistically (paired Student t-test, P<0.05). Facial expressions of lip purse, cheek puff, and raising of eyebrows were reproducible. Facial expressions of maximum smile and forceful eye closure were not reproducible. The limited coordination of various groups of facial muscles contributed to the lack of reproducibility of these facial expressions. 4D imaging is a useful clinical tool for the assessment of facial expressions. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Diagnostic performance of reproducible chest wall tenderness to rule out acute coronary syndrome in acute chest pain: a prospective diagnostic study

    PubMed Central

    Gräni, Christoph; Senn, Oliver; Bischof, Manuel; Cippà, Pietro E; Hauffe, Till; Zimmerli, Lukas; Battegay, Edouard; Franzen, Daniel

    2015-01-01

    Objectives Acute chest pain (ACP) is a leading cause of hospital emergency unit consultation. As there are various underlying conditions, ranging from musculoskeletal disorders to acute coronary syndrome (ACS), thorough clinical diagnostics are warranted. The aim of this prospective study was to assess whether reproducible chest wall tenderness (CWT) on palpation in patients with ACP can help to rule out ACS. Methods In this prospective, double-blinded diagnostic study, all consecutive patients assessed in the emergency unit at the University Hospital Zurich because of ACP between July 2012 and December 2013 were included when a member of the study team was present. Reproducible CWT on palpation was the initial step and was recorded before further examinations were initiated. The final diagnosis was adjudicated by a study-independent physician. Results 121 patients (60.3% male, median age 47 years, IQR 34–66.5 years) were included. The prevalence of ACS was 11.6%. Non-reproducible CWT had a high sensitivity of 92.9% (95% CI 66.1% to 98.8%) for ACS and the presence of reproducible CWT ruled out ACS (p=0.003) with a high negative predictive value (98.1%, 95% CI 89.9% to 99.7%). Conversely non-reproducible CWT ruled in ACS with low specificity (48.6%, 95% CI 38.8% to 58.5%) and low positive predictive value (19.1%, 95% CI 10.6% to 30.5%). Conclusions This prospective diagnostic study supports the concept that reproducible CWT helps to rule out ACS in patients with ACP in an early stage of the evaluation process. However, ACS and other diagnoses should be considered in patients with a negative CWT test. Trial registration number ClinicalTrial.gov: NCT01724996. PMID:25631316

  2. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    PubMed

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  3. Can cancer researchers accurately judge whether preclinical reports will reproduce?

    PubMed Central

    Mandel, David R.; Kimmelman, Jonathan

    2017-01-01

    There is vigorous debate about the reproducibility of research findings in cancer biology. Whether scientists can accurately assess which experiments will reproduce original findings is important to determining the pace at which science self-corrects. We collected forecasts from basic and preclinical cancer researchers on the first 6 replication studies conducted by the Reproducibility Project: Cancer Biology (RP:CB) to assess the accuracy of expert judgments on specific replication outcomes. On average, researchers forecasted a 75% probability of replicating the statistical significance and a 50% probability of replicating the effect size, yet none of these studies successfully replicated on either criterion (for the 5 studies with results reported). Accuracy was related to expertise: experts with higher h-indices were more accurate, whereas experts with more topic-specific expertise were less accurate. Our findings suggest that experts, especially those with specialized knowledge, were overconfident about the RP:CB replicating individual experiments within published reports; researcher optimism likely reflects a combination of overestimating the validity of original studies and underestimating the difficulties of repeating their methodologies. PMID:28662052

  4. A comparison between laser-doppler imaging and colorimetry in the assessment of scarring: "a pilot study".

    PubMed

    Peeters, Wouter; Anthonissen, Mieke; Deliaert, An; Van der Hulst, Rene; Van den Kerckhove, Eric

    2012-05-01

    This cross-sectional pilot-study investigated the reproducibility of the LDI (Moor-LDI-B2; Moor Instruments) and the chromameter (Minolta chromameter CR-300) when used in scar assessment. Twenty-seven scars in 14 subjects were included between January and June 2003. One observer performed two times both measurements with 10 min apart. The intra-observer agreement is quantified by means of the intra-class correlations (ICC) and the standard errors of measurement (SEM) for both the LDI and the chromameter. Ignoring one outlier, the ICC of the LDI = 0.856 and the SEM = 34.56. The chromameter shows a better reproducibility with an ICC of 0.93 and a SEM of 0.79. This pilot-study with a limited number of measurements shows a moderate reproducibility of the LDI compared to the chromameter measurements, in the assessment of respectively flux and redness in scars. © 2011 John Wiley & Sons A/S.

  5. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    PubMed

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  6. Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease

    PubMed Central

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph

    2018-01-01

    Purpose To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Methods Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test–retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Results Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] −1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR −1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. Conclusion The microperimeter MP3 shows an adequate test–retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Translational Relevance Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies. PMID:29430338

  7. Test-Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease.

    PubMed

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph; Findl, Oliver

    2018-02-01

    To evaluate the test-retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test-retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] -1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR -1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. The microperimeter MP3 shows an adequate test-retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.

  8. Potential of Contrast-Enhanced Ultrasound as a Bedside Monitoring Technique in Cerebral Perfusion: a Systematic Review.

    PubMed

    Vinke, Elisabeth J; Kortenbout, Anna J; Eyding, Jens; Slump, Cornelis H; van der Hoeven, Johannes G; de Korte, Chris L; Hoedemaekers, Cornelia W E

    2017-12-01

    Contrast-enhanced ultrasound (CEUS) has been suggested as a new method to measure cerebral perfusion in patients with acute brain injury. In this systematic review, the tolerability, repeatability, reproducibility and accuracy of different CEUS techniques for the quantification of cerebral perfusion were assessed. We selected studies published between January 1994 and March 2017 using CEUS to measure cerebral perfusion. We included 43 studies (bolus kinetics n = 31, refill kinetics n = 6, depletion kinetics n = 6) with a total of 861 patients. Tolerability was reported in 28 studies describing 12 patients with mild and transient side effects. Repeatability was assessed in 3 studies, reproducibility in 2 studies and accuracy in 19 studies. Repeatability was high for experienced sonographers and significantly lower for less experienced sonographers. Reproducibility of CEUS was not clear. The sensitivity and specificity of CEUS for the detection of cerebral ischemia ranged from 75% to 96% and from 60% to 100%. Limited data on repeatability, reproducibility and accuracy may suggest that this technique could be feasible for use in acute brain injury patients. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  9. Natural progression of blood-induced joint damage in patients with haemophilia: clinical relevance and reproducibility of three-dimensional gait analysis.

    PubMed

    Lobet, S; Detrembleur, C; Francq, B; Hermans, C

    2010-09-01

    A major complication in haemophilia is the destruction of joint cartilage because of recurrent intraarticular and intramuscular bleeds. Therefore, joint assessment is critical to quantify the extent of joint damage, which has traditionally been evaluated using both radiological and clinical joint scores. Our study aimed to evaluate the natural progression of haemophilic arthopathy using three-dimensional gait analysis (3DGA) and to assess the reproducibility of this technique. We hypothesized that the musculoskeletal function was relatively stable in patients with haemophilia. Eighteen adults with established haemophilic arthropathies were evaluated twice by 3DGA (mean follow-up: 18 +/- 5 weeks). Unexpectedly, our findings revealed infraclinical deterioration of gait pattern, characterized by a 3.2% decrease in the recovery index, which is indicative of the subject's ability to save energy while walking. A tendency towards modification of segmental joint function was also observed. Gait analysis was sufficiently reproducible with regards to spatiotemporal parameters as well as kinetic, mechanical and energetic gait variables. The kinematic variables were reproducible in both the sagittal and frontal planes. In conclusion, 3DGA is a reproducible tool to assess abnormal gait patterns and monitor natural disease progression in haemophilic patients.

  10. HiCRep: assessing the reproducibility of Hi-C data using a stratum-adjusted correlation coefficient.

    PubMed

    Yang, Tao; Zhang, Feipeng; Yardımcı, Galip Gürkan; Song, Fan; Hardison, Ross C; Noble, William Stafford; Yue, Feng; Li, Qunhua

    2017-11-01

    Hi-C is a powerful technology for studying genome-wide chromatin interactions. However, current methods for assessing Hi-C data reproducibility can produce misleading results because they ignore spatial features in Hi-C data, such as domain structure and distance dependence. We present HiCRep, a framework for assessing the reproducibility of Hi-C data that systematically accounts for these features. In particular, we introduce a novel similarity measure, the stratum adjusted correlation coefficient (SCC), for quantifying the similarity between Hi-C interaction matrices. Not only does it provide a statistically sound and reliable evaluation of reproducibility, SCC can also be used to quantify differences between Hi-C contact matrices and to determine the optimal sequencing depth for a desired resolution. The measure consistently shows higher accuracy than existing approaches in distinguishing subtle differences in reproducibility and depicting interrelationships of cell lineages. The proposed measure is straightforward to interpret and easy to compute, making it well-suited for providing standardized, interpretable, automatable, and scalable quality control. The freely available R package HiCRep implements our approach. © 2017 Yang et al.; Published by Cold Spring Harbor Laboratory Press.

  11. Periodontal repair in dogs: examiner reproducibility in the supraalveolar periodontal defect model.

    PubMed

    Koo, Ki-Tae; Polimeni, Giuseppe; Albandar, Jasim M; Wikesjö, Ulf M E

    2004-06-01

    Histometric assessments are routinely used to evaluate biologic events ascertained in histologic sections acquired from animal and human studies. The objective of this study was to evaluate the intra- and inter-examiner reproducibility of histometric assessments in the supraalveolar periodontal defect model. Histometric analysis using incandescent and polarized light microscopy, an attached digital camera system, and a PC-based image analysis system including a custom program for the supraalveolar periodontal defect model was performed on histologic sections acquired from one jaw quadrant in each of 12 dogs. The animals had received an experimental protocol including implantation of a coral biomaterial and guided tissue regeneration (GTR) barrier devices, and were evaluated following a 4-week healing interval. Histometric parameters were recorded and repeated within a 3-month interval by two examiners following brief training. Intra- and inter-examiner reproducibility was assessed using the intra-class correlation coefficient (ICC). Most parameters showed high intra-examiner ICCs. Parameters including defect height, connective tissue repair, bone regeneration (height/area), formation of a junctional epithelium, positioning of the GTR device, ankylosis, root resorption, and defect area yielded an ICC> or 0..9. The ICCs for bone density and biomaterial density were somewhat lower (0.8 and 0.7, respectively). The inter-examiner reproducibility was somewhat lower compared to the intra-examiner reproducibility. Nevertheless, the ICCs were generally high (ICC range: 0.6-0.9). Histometric evaluations in the supraalveolar periodontal defect model yield highly reproducible results, in particular when a single examiner performs the histometric measurements, even when the examiner was exposed to limited training.

  12. Reproducibility of cervical range of motion in patients with neck pain

    PubMed Central

    Hoving, Jan Lucas; Pool, Jan JM; van Mameren, Henk; Devillé, Walter JLM; Assendelft, Willem JJ; de Vet, Henrica CW; de Winter, Andrea F; Koes, Bart W; Bouter, Lex M

    2005-01-01

    Background Reproducibility measurements of the range of motion are an important prerequisite for the interpretation of study results. The aim of the study is to assess the intra-rater and inter-rater reproducibility of the measurement of active Range of Motion (ROM) in patients with neck pain using the Cybex Electronic Digital Inclinometer-320 (EDI-320). Methods In an outpatient clinic in a primary care setting 32 patients with at least 2 weeks of pain and/or stiffness in the neck were randomly assessed, in a test- retest design with blinded raters using a standardized measurement protocol. Cervical flexion-extension, lateral flexion and rotation were assessed. Results Reliability expressed by the Intraclass Correlation Coefficient (ICC) was 0.93 (lateral flexion) or higher for intra-rater reliability and 0.89 (lateral flexion) or higher for inter-rater reliability. The 95% limits of agreement for intra-rater agreement, expressing the range of the differences between two ratings were -2.5 ± 11.1° for flexion-extension, -0.1 ± 10.4° for lateral flexion and -5.9 ± 13.5° for rotation. For inter-rater agreement the limits of agreement were 3.3 ± 17.0° for flexion-extension, 0.5 ± 17.0° for lateral flexion and -1.3 ± 24.6° for rotation. Conclusion In general, the intra-rater reproducibility and the inter-rater reproducibility were good. We recommend to compare the reproducibility and clinical applicability of the EDI-320 inclinometer with other cervical ROM measures in symptomatic patients. PMID:16351719

  13. Experimental investigations into visual and electronic tooth color measurement.

    PubMed

    Ratzmann, Anja; Treichel, Anja; Langforth, Gabriele; Gedrange, Tomasz; Welk, Alexander

    2011-04-01

    The present study aimed to examine the validity of the visual color assessment and an electronic tooth color measurement system by means of Shade Inspector™ in comparison with a gold standard. Additionally, reproducibility of electronic measurements was demonstrated by means of two reference systems. Ceramic specimens of two thicknesses (h=1.6 mm, h=2.6 mm) were used. Three experienced dental technicians using the VITAPAN Classical(®) color scale carried out all visual tests. Validity of the visual assessment and the electronic measurements was confirmed separately for both thicknesses by means of lightness and hue of the VITAPAN Classical(®) color scale. Reproducibility of electronic measurements was confirmed by means of the VITAPAN Classical(®) and 3D-Master(®). The 3D-Master(®) data were calculated according to lightness, hue and chroma. Intraclass correlation coefficient (ICC) was used in assessing validity/reproducibility for lightness and chroma, Kappa statistics were used for hue. A level ≥0.75 was pre-established for ICC and ≥0.60 for the Kappa index. RESULTS OF VISUAL COLOR ASSESSMENT: Validity for lightness was good for both thicknesses; agreement rates for hue were inconsistent. ELECTRONIC MEASUREMENT: Validity for lightness was fair to good, hue values were below 0.60. Reproducibility of lightness was good to very good for both reference systems. Hue values (VITAPAN Classical(®)) for 1.6 mm test specimens were upside, for 2.6 mm below 0.60, Kappa values for 3D-Master(®) were ≥0.60 for all measurements, reproducibility of chroma was very good. Validity was better for visual than for electronic color assessment. Reproducibility of the electronic device by means of the Shade Inspector™ was given for the VITAPAN Classical(®) and 3D-Master(®) systems.

  14. [Prognosis of the reproducibility of increased systolic arterial blood pressure in adolescents (an international cooperative study of juvenile arterial hypertension)].

    PubMed

    1986-10-01

    Three-year reproducibility of elevated (above 120 mmHg) systolic BP (BPs) in twelve- and thirteen-year-olds was studied on the basis of the data of an international collaborative study in juvenile arterial hypertension. Rules for the classification and regulation of the adolescents of both sexes by their tendency to reproduce elevated BPs were derived, using logical functions. The rules are presented as logical solution trees that make it possible to assess the probability of elevated BPs being maintained and identify the adolescents prone to persistent BPs rise.

  15. Female fecundity variation affects reproducibility of experiments on host plant preference and acceptance in a phytophagous insect

    PubMed Central

    Schäpers, Alexander; Petrén, Hampus; Wheat, Christopher W.; Wiklund, Christer

    2017-01-01

    Reproducibility is a scientific cornerstone. Many recent studies, however, describe a reproducibility crisis and call for assessments of reproducibility across scientific domains. Here, we explore the reproducibility of a classic ecological experiment—that of assessing female host plant preference and acceptance in phytophagous insects, a group in which host specialization is a key driver of diversification. We exposed multiple cohorts of Pieris napi butterflies from the same population to traditional host acceptance and preference tests on three Brassicaceae host species. Whereas the host plant rank order was highly reproducible, the propensity to oviposit on low-ranked hosts varied significantly even among cohorts exposed to similar conditions. Much variation could be attributed to among-cohort variation in female fecundity, a trait strongly correlated both to female size and to the size of the nuptial gift a female receives during mating. Small males provide small spermatophores, and in our experiment small females that mated with small males had a disproportionally low propensity to oviposit on low-ranked hosts. Hence, our results provide empirical support to the theoretical prediction that female host utilization is strongly affected by non-genetic, environmental variation, and that such variation can affect the reproducibility of ecological experiments even under seemingly identical conditions. PMID:28202813

  16. Twelve-hour reproducibility of retinal and optic nerve blood flow parameters in healthy individuals.

    PubMed

    Luksch, Alexandra; Lasta, Michael; Polak, Kaija; Fuchsjäger-Mayrl, Gabriele; Polska, Elzbieta; Garhöfer, Gerhard; Schmetterer, Leopold

    2009-11-01

    The aim of the present study was to investigate the reproducibility and potential diurnal variation of optic nerve head and retinal blood flow parameters in healthy individuals over a period of 12 hr. We measured optic nerve head and retinal blood flow parameters in 16 healthy male non-smoking individuals at five time-points during the day (08:00, 11:00, 14:00, 17:00 and 20:00 hr). Outcome parameters were perimacular white blood cell flux (as assessed with the blue field entoptic technique), blood velocities in retinal veins (as assessed with bi-directional laser Doppler velocimetry), retinal arterial and venous diameters (as assessed with the retinal vessel analyser), optic nerve head blood flow, volume and velocity (as assessed with single point and scanning laser Doppler flowmetry) and blood velocities in the central retinal artery (as assessed with colour Doppler imaging). The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. No diurnal variation in optic nerve head or retinal blood flow was observed with any of the techniques employed. Coefficients of variation were between 1.6% and 18.5% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 3.7% to 78.2%. Our data indicate that in healthy individuals the selected techniques provide adequate reproducibility to be used in clinical studies. However, in patients with eye diseases and reduced vision the reproducibility may be considerably worse.

  17. Test-Retest Reproducibility of Two Short-Form Balance Measures Used in Individuals with Stroke

    ERIC Educational Resources Information Center

    Liaw, Lih-Jiun; Hsieh, Ching-Lin; Hsu, Miao-Ju; Chen, Hui-Mei; Lin, Jau-Hong; Lo, Sing-Kai

    2012-01-01

    The aim of this study is to determine the test-retest reproducibility of the seven-item Short-Form Berg Balance Scale (SFBBS) and the five-item Short-Form Postural Assessment Scale for Stroke Patients (SFPASS) in individuals with chronic stroke. Fifty-two chronic stroke patients from two rehabilitation departments were included in the study. Both…

  18. Reproducibility patterns of multiple rapid swallows during high resolution esophageal manometry provide insights into esophageal pathophysiology.

    PubMed

    Price, L H; Li, Y; Patel, A; Gyawali, C Prakash

    2014-05-01

    Multiple rapid swallows (MRS) during esophageal high resolution manometry (HRM) assess esophageal neuromuscular integrity by evaluating postdeglutitive inhibition and rebound contraction, but most reports performed only a single MRS sequence. We assessed patterns of MRS reproducibility during clinical HRM in comparison to a normal cohort. Consecutive clinical HRM studies were included if two separate MRS sequences (four to six rapid swallows ≤4 s apart) were successfully performed. Chicago Classification diagnoses were identified; contraction wave abnormalities were additionally recorded. MRS-induced inhibition (contraction ≤3 cm during inhibition phase) and rebound contraction was assessed, and findings compared to 18 controls (28.0 ± 0.7 year, 50.0% female). Reproducibility consisted of similar inhibition and contraction responses with both sequences; discordance was segregated into inhibition and contraction phases. Multiple rapid swallows were successfully performed in 89.3% patients and all controls; 225 subjects (56.2 ± 0.9 year, 62.7% female) met study inclusion criteria. Multiple rapid swallows were reproducible in 76.9% patients and 94.4% controls (inhibition phase: 88.0% vs 94.4%, contraction phase 86.7% vs 100%, respectively, p = ns). A gradient of reproducibility was noted, highest in well-developed motor disorders (achalasia spectrum, hypermotility disorders, and aperistalsis, 91.7-100%, p = ns compared to controls); and lower in lesser motor disorders (contraction wave abnormalities, esophageal body hypomotility) or normal studies (62.2-70.8%, p < 0.0001 compared to well-developed motor disorders). Inhibition phase was most discordant in contraction wave abnormalities, while contraction phase was most discordant when studies were designated normal. Multiple rapid swallows are highly reproducible, especially in well-developed motor disorders, and complement the standard wet swallow manometry protocol. © 2014 John Wiley & Sons Ltd.

  19. Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study).

    PubMed

    Margossian, Renee; Schwartz, Marcy L; Prakash, Ashwin; Wruck, Lisa; Colan, Steven D; Atz, Andrew M; Bradley, Timothy J; Fogel, Mark A; Hurwitz, Lynne M; Marcus, Edward; Powell, Andrew J; Printz, Beth F; Puchalski, Michael D; Rychik, Jack; Shirali, Girish; Williams, Richard; Yoo, Shi-Joon; Geva, Tal

    2009-08-01

    Assessment of the size and function of a functional single ventricle (FSV) is a key element in the management of patients after the Fontan procedure. Measurement variability of ventricular mass, volume, and ejection fraction (EF) among observers by echocardiography and cardiac magnetic resonance imaging (CMR) and their reproducibility among readers in these patients have not been described. From the 546 patients enrolled in the Pediatric Heart Network Fontan Cross-Sectional Study (mean age 11.9 +/- 3.4 years), 100 echocardiograms and 50 CMR studies were assessed for measurement reproducibility; 124 subjects with paired studies were selected for comparison between modalities. Interobserver agreement for qualitative grading of ventricular function by echocardiography was modest for left ventricular (LV) morphology (kappa = 0.42) and weak for right ventricular (RV) morphology (kappa = 0.12). For quantitative assessment, high intraclass correlation coefficients were found for echocardiographic interobserver agreement (LV 0.87 to 0.92, RV 0.82 to 0.85) of systolic and diastolic volumes, respectively. In contrast, intraclass correlation coefficients for LV and RV mass were moderate (LV 0.78, RV 0.72). The corresponding intraclass correlation coefficients by CMR were high (LV 0.96, RV 0.85). Volumes by echocardiography averaged 70% of CMR values. Interobserver reproducibility for the EF was similar for the 2 modalities. Although the absolute mean difference between modalities for the EF was small (<2%), 95% limits of agreement were wide. In conclusion, agreement between observers of qualitative FSV function by echocardiography is modest. Measurements of FSV volume by 2-dimensional echocardiography underestimate CMR measurements, but their reproducibility is high. Echocardiographic and CMR measurements of FSV EF demonstrate similar interobserver reproducibility, whereas measurements of FSV mass and LV diastolic volume are more reproducible by CMR.

  20. Reproducibility assessment of brain responses to visual food stimuli in adults with overweight and obesity.

    PubMed

    Drew Sayer, R; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W

    2016-10-01

    The brain's reward system influences ingestive behavior and subsequently obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. This study sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n = 16) and men (n = 12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the two testing days. Mean fasting-state brain responses on day 2 were reduced compared with day 1 in the left insula and right amygdala, but mean day 1 and day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. © 2016 The Obesity Society.

  1. The Reproducibility and Relative Validity of a Mexican Diet Quality Index (ICDMx) for the Assessment of the Habitual Diet of Adults

    PubMed Central

    Macedo-Ojeda, Gabriela; Márquez-Sandoval, Fabiola; Fernández-Ballart, Joan; Vizmanos, Barbara

    2016-01-01

    The study of diet quality in a population provides information for the development of programs to improve nutritional status through better directed actions. The aim of this study was to assess the reproducibility and relative validity of a Mexican Diet Quality Index (ICDMx) for the assessment of the habitual diet of adults. The ICDMx was designed to assess the characteristics of a healthy diet using a validated semi-quantitative food frequency questionnaire (FFQ-Mx). Reproducibility was determined by comparing 2 ICDMx based on FFQs (one-year interval). Relative validity was assessed by comparing the ICDMx (2nd FFQ) with that estimated based on the intake averages from dietary records (nine days). The questionnaires were answered by 97 adults (mean age in years = 27.5, SD = 12.6). Pearson (r) and intraclass correlations (ICC) were calculated; Bland-Altman plots, Cohen’s κ coefficients and blood lipid determinations complemented the analysis. Additional analysis compared ICDMx scores with nutrients derived from dietary records, using a Pearson correlation. These nutrient intakes were transformed logarithmically to improve normality (log10) and adjusted according to energy, prior to analyses. The ICDMx obtained ICC reproducibility values ranged from 0.33 to 0.87 (23/24 items with significant correlations; mean = 0.63), while relative validity ranged from 0.26 to 0.79 (mean = 0.45). Bland-Altman plots showed a high level of agreement between methods. ICDMx scores were inversely correlated (p < 0.05) with total blood cholesterol (r = −0.33) and triglycerides (r = −0.22). ICDMx (as calculated from FFQs and DRs) obtained positive correlations with fiber, magnesium, potassium, retinol, thiamin, riboflavin, pyridoxine, and folate. The ICDMx obtained acceptable levels of reproducibility and relative validity in this population. It can be useful for population nutritional surveillance and to assess the changes resulting from the implementation of nutritional interventions. PMID:27563921

  2. Diagnostic performance of reproducible chest wall tenderness to rule out acute coronary syndrome in acute chest pain: a prospective diagnostic study.

    PubMed

    Gräni, Christoph; Senn, Oliver; Bischof, Manuel; Cippà, Pietro E; Hauffe, Till; Zimmerli, Lukas; Battegay, Edouard; Franzen, Daniel

    2015-01-28

    Acute chest pain (ACP) is a leading cause of hospital emergency unit consultation. As there are various underlying conditions, ranging from musculoskeletal disorders to acute coronary syndrome (ACS), thorough clinical diagnostics are warranted. The aim of this prospective study was to assess whether reproducible chest wall tenderness (CWT) on palpation in patients with ACP can help to rule out ACS. In this prospective, double-blinded diagnostic study, all consecutive patients assessed in the emergency unit at the University Hospital Zurich because of ACP between July 2012 and December 2013 were included when a member of the study team was present. Reproducible CWT on palpation was the initial step and was recorded before further examinations were initiated. The final diagnosis was adjudicated by a study-independent physician. 121 patients (60.3% male, median age 47 years, IQR 34-66.5 years) were included. The prevalence of ACS was 11.6%. Non-reproducible CWT had a high sensitivity of 92.9% (95% CI 66.1% to 98.8%) for ACS and the presence of reproducible CWT ruled out ACS (p=0.003) with a high negative predictive value (98.1%, 95% CI 89.9% to 99.7%). Conversely non-reproducible CWT ruled in ACS with low specificity (48.6%, 95% CI 38.8% to 58.5%) and low positive predictive value (19.1%, 95% CI 10.6% to 30.5%). This prospective diagnostic study supports the concept that reproducible CWT helps to rule out ACS in patients with ACP in an early stage of the evaluation process. However, ACS and other diagnoses should be considered in patients with a negative CWT test. ClinicalTrial.gov: NCT01724996. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Translation, cultural adaptation and validation into portuguese (Brazil) in Systemic Sclerosis Questionnaire (SySQ).

    PubMed

    Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros

    2014-01-01

    Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized methodology for translation and cultural adaptation of questionnaires, as well as to assess the reproducibility and validity.

  4. Reproducibility of an optical measurement system for the clinical evaluation of active knee rotation in weight-bearing, healthy subjects.

    PubMed

    Testa, R; Chouteau, J; Viste, A; Cheze, L; Fessy, M-H; Moyen, B

    2012-04-01

    A knee is typically evaluated passively by a clinician during an office visit, without using dedicated measurement tools. When the knee is evaluated with the patient standing and actively participating in the movement, the results will differ than when the knee is passively moved through its range-of-motion by the surgeon. If a precise measurement system was available, it could provide additional information to the clinician during this evaluation. The goal of this study was to verify the reproducibility of a fast, flexible optical measurement system to measure rotational knee laxity during weight-bearing. Two passive reflective targets were placed on the legs of 11 subjects to monitor femur and tibia displacements in three dimensions. Subjects performed internal and external rotation movements with the knee extended or flexed 30°. During each movement, seven variables were measured: internal rotation, external rotation and overall laxity in extension and 30° flexion, along with neutral rotation value in 30° flexion. Measurement accuracy was also assessed and the right and left knees were compared. Reproducibility was assessed over two measurements sessions. The calculated intra-class correlation coefficient (ICC) for reproducibility was above 0.9 for five of the seven variables measured. The calculated ICC for the right/left comparison was above 0.75 for five of the seven variables measured. These results confirmed that the proposed system provides reproducible measurements. Our right/left comparison results were consistent with the published literature. This system is fast, reproducible and flexible, which makes it suitable for assessing various weight-bearing movements during clinical evaluations. Level III, experimental study. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle.

    PubMed

    Semelka, R C; Tomei, E; Wagner, S; Mayo, J; Caputo, G; O'Sullivan, M; Parmley, W W; Chatterjee, K; Wolfe, C; Higgins, C B

    1990-06-01

    The validity of geometric formulas to derive mass and volumes in the morphologically abnormal left ventricle is problematic. Imaging techniques that are tomographic and therefore inherently three-dimensional should be more reliable and reproducible between studies in such ventricles. Determination of reproducibility between studies is essential to define the limits of an imaging technique for evaluating the response to therapy. Sequential cine magnetic resonance (MR) studies were performed on patients with dilated cardiomyopathy (n = 11) and left ventricular hypertrophy (n = 8) within a short interval in order to assess interstudy reproducibility. Left ventricular mass, volumes, ejection fraction, and end-systolic wall stress were determined by two independent observers. Between studies, left ventricular mass was highly reproducible for hypertrophied and dilated ventricles, with percent variability less than 6%. Ejection fraction and end-diastolic volume showed close reproducibility between studies, with percent variability less than 5% End-systolic volume varied by 4.3% and 4.5% in dilated cardiomyopathy and 8.4% and 7.2% in left ventricular hypertrophy for the two observers. End-systolic wall stress, which is derived from multiple measurements, varied the greatest, with percent variability of 17.2% and 15.7% in dilated cardiomyopathy and 14.8% and 13% in left ventricular hypertrophy, respectively. The results of this study demonstrate that mass, volume, and functional measurements are reproducible in morphologically abnormal ventricles.

  6. How measurement science can improve confidence in research results.

    PubMed

    Plant, Anne L; Becker, Chandler A; Hanisch, Robert J; Boisvert, Ronald F; Possolo, Antonio M; Elliott, John T

    2018-04-01

    The current push for rigor and reproducibility is driven by a desire for confidence in research results. Here, we suggest a framework for a systematic process, based on consensus principles of measurement science, to guide researchers and reviewers in assessing, documenting, and mitigating the sources of uncertainty in a study. All study results have associated ambiguities that are not always clarified by simply establishing reproducibility. By explicitly considering sources of uncertainty, noting aspects of the experimental system that are difficult to characterize quantitatively, and proposing alternative interpretations, the researcher provides information that enhances comparability and reproducibility.

  7. Apparent diffusion coefficient of the normal human brain for various experimental conditions

    NASA Astrophysics Data System (ADS)

    Moraru, Luminita; Dimitrievici, Lucian

    2017-01-01

    Diffusion-Weighted Magnetic Resonance Imaging (DW-MRI) is being increasingly used to assess both brain tissues and cerebrospinal fluid integrity. In this paper we study inter-site reproducibility of the apparent diffusion coefficient values for the main cerebral tissues such as gray matter, white matter and into cerebrospinal fluid and for three different stacks of slices that were spaced at L = 79.8, 84.9 and 90 mm. We assessed the impact of the attenuation factor and diffusion gradient on the results reproducibility.

  8. Reproducibility studies for experimental epitope detection in macrophages (EDIM).

    PubMed

    Japink, Dennis; Nap, Marius; Sosef, Meindert N; Nelemans, Patty J; Coy, Johannes F; Beets, Geerard; von Meyenfeldt, Maarten F; Leers, Math P G

    2014-05-01

    We have recently described epitope detection in macrophages (EDIM) by flow cytometry. This is a promising tool for the diagnosis and follow-up of malignancies. However, biological and technical validation is warranted before clinical applicability can be explored. The pre-analytic and analytic phases were investigated. Five different aspects were assessed: blood sample stability, intra-individual variability in healthy persons, intra-assay variation, inter-assay variation and assay transferability. The post-analytic phase was already partly standardized and described in an earlier study. The outcomes in the pre-analytic phase showed that samples are stable for 24h after venipuncture. Biological variation over time was similar to that of serum tumor marker assays; each patient has a baseline value. Intra-assay variation showed good reproducibility, while inter-assay variation showed reproducibility similar to that of to established serum tumor marker assays. Furthermore, the assay showed excellent transferability between analyzers. Under optimal analytic conditions the EDIM method is technically stable, reproducible and transferable. Biological variation over time needs further assessment in future work. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Reproducibility of current perception threshold with the Neurometer(®) vs the Stimpod NMS450 peripheral nerve stimulator in healthy volunteers: an observational study.

    PubMed

    Tsui, Ban C H; Shakespeare, Timothy J; Leung, Danika H; Tsui, Jeremy H; Corry, Gareth N

    2013-08-01

    Current methods of assessing nerve blocks, such as loss of perception to cold sensation, are subjective at best. Transcutaneous nerve stimulation is an alternative method that has previously been used to measure the current perception threshold (CPT) in individuals with neuropathic conditions, and various devices to measure CPT are commercially available. Nevertheless, the device must provide reproducible results to be used as an objective tool for assessing nerve blocks. We recruited ten healthy volunteers to examine CPT reproducibility using the Neurometer(®) and the Stimpod NMS450 peripheral nerve stimulator. Each subject's CPT was determined for the median (second digit) and ulnar (fifth digit) nerve sensory distributions on both hands - with the Neurometer at 5 Hz, 250 Hz, and 2000 Hz and with the Stimpod at pulse widths of 0.1 msec, 0.3 msec, 0.5 msec, and 1.0 msec, both at 5 Hz and 2 Hz. Intraclass correlation coefficients (ICC) were also calculated to assess reproducibility; acceptable ICCs were defined as ≥ 0.4. The ICC values for the Stimpod ranged from 0.425-0.79, depending on pulse width, digit, and stimulation; ICCs for the Neurometer were 0.615 and 0.735 at 250 and 2,000 Hz, respectively. These values were considered acceptable; however, the Neurometer performed less efficiently at 5 Hz (ICCs for the second and fifth digits were 0.292 and 0.318, respectively). Overall, the Stimpod device displayed good to excellent reproducibility in measuring CPT in healthy volunteers. The Neurometer displayed poor reproducibility at low frequency (5 Hz). These results suggest that peripheral nerve stimulators may be potential devices for measuring CPT to assess nerve blocks.

  10. Urinary incontinence self-report questions: reproducibility and agreement with bladder diary.

    PubMed

    Bradley, Catherine S; Brown, Jeanette S; Van Den Eeden, Stephen K; Schembri, Michael; Ragins, Arona; Thom, David H

    2011-12-01

    This study aims to measure self-report urinary incontinence questions' reproducibility and agreement with bladder diary. Data were analyzed from the Reproductive Risk of Incontinence Study at Kaiser. Participating women reporting at least weekly incontinence completed self-report incontinence questions and a 7-day bladder diary. Self-report question reproducibility was assessed and agreement between self-reported and diary-recorded voiding and incontinence frequency was measured. Test characteristics and area under the curve were calculated for self-reported incontinence types using diary as the gold standard. Five hundred ninety-one women were included and 425 completed a diary. The self-report questions had moderate reproducibility and self-reported and diary-recorded incontinence and voiding frequencies had moderate to good agreement. Self-reported incontinence types identified stress and urgency incontinence more accurately than mixed incontinence. Self-report incontinence questions have moderate reproducibility and agreement with diary, and considering their minimal burden, are acceptable research tools in epidemiologic studies.

  11. Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice.

    PubMed

    Haggerty, Christopher M; Kramer, Sage P; Binkley, Cassi M; Powell, David K; Mattingly, Andrea C; Charnigo, Richard; Epstein, Frederick H; Fornwalt, Brandon K

    2013-08-27

    Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice. Five normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15-20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer's analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility. LV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent reproducibility with CoVs of 1% and 3%, respectively. Finally, peak measures (e.g., strains) were generally more reproducible than the corresponding rates of change (e.g., strain rate). Cine DENSE CMR is a highly reproducible technique for quantification of advanced measures of left ventricular cardiac function in mice including strains, torsion and measures of synchrony. However, myocardial twist angles are not reproducible and future studies should instead report torsion.

  12. Within-person reproducibility of red blood cell mercury over a 10- to 15-year period among women in the Nurses' Health Study II.

    PubMed

    Kioumourtzoglou, Marianthi-Anna; Roberts, Andrea L; Nielsen, Flemming; Tworoger, Shelley S; Grandjean, Philippe; Weisskopf, Marc G

    2016-01-01

    Most epidemiologic studies of methylmercury (MeHg) health effects rely on a single measurement of a MeHg biomarker to assess long-term exposures. Long-term reproducibility data are, therefore, needed to assess the reliability of a single measure to reflect long-term exposures. In this study, we assessed within-person reproducibility of red blood cell (RBC) mercury (Hg), a marker of methyl-mercury, over 10-15 years in a sample of 57 women. Fifty-seven women from the Nurses' Health Study II provided two blood samples 10-15-years apart (median: 12 years), which were analyzed for mercury levels in the red blood cells (B-Hg*). To characterize within-person reproducibility, we estimated correlation and intraclass correlation coefficients (r and ICC) across the two samples. Further, we compared different prediction models, including variables on fish and seafood consumption, for B-Hg* at the first sample, using leave-one-out cross-validation to assess predictive ability. Overall, we observed strong correlations over 10-15 years (r=0.69), as well as a high ICC (0.67; 95% CI: 0.49, 0.79). Fish and seafood consumption reported concurrently with the first B-Hg* sample accounted for 26.8% of the variability in that B-Hg*, giving a correlation of r=0.52. Despite decreasing B-Hg* levels over time, we observed strong correlations and high ICC estimates across B-Hg* measured 10-15 years apart, suggesting good relative within-person stability over time. Our results indicate that a single measurement of B-Hg* likely is adequate to represent long-term exposures.

  13. [Good reproducibility of a 14-item food frequency questionnaire for cardiovascular prevention in students].

    PubMed

    Balquet, L; Noury-Desvaux, B; Jaquinandi, V; Mahé, G

    2015-02-01

    Diet is a modifiable risk factor of atherosclerosis. A 14-item food frequency questionnaire (FFQ) has been developed. The reproducibility of this FFQ is unknown in a student population whereas its use could be of interest. This FFQ allows calculating different scores for different food groups involved in cardiovascular disease. The vascular dietary score (VDS) can be calculated. The VSD ranges from -17 to +19. The higher the VSD, the better diet. Reproducibility was assessed in sports faculty students using mean tests comparing measurement 1 and 2 (minimum time interval ≥ 7 days) and intra-class correlation (ICC) tests. Thirty students (50% men) were included in a French Sports Faculty. Time between two FFQ assessments was 19 ± 9 days. Mean VSD was 0.50 ± 3.70 for the first assessment and 0.30 ± 3.14 for the second one (non significant). Any score for each food group was statistically significant between the first and the second measurement. ICC of VSD was 0.68 [95% confidence interval: 0.43-0.83]. This FFQ that assesses a risky vascular diet has good reproducibility. This tool could be useful for large studies involving students. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. The search and selection for primary studies in systematic reviews published in dental journals indexed in MEDLINE was not fully reproducible.

    PubMed

    Faggion, Clovis Mariano; Huivin, Raquel; Aranda, Luisiana; Pandis, Nikolaos; Alarcon, Marco

    2018-06-01

    To evaluate whether the reporting of search strategies and the primary study selection process in dental systematic reviews is reproducible. A survey of systematic reviews published in MEDLINE-indexed dental journals from June 2015 to June 2016 was conducted. Study selection was performed independently by two authors, and the reproducibility of the selection process was assessed using a tool consisting of 12 criteria. Regression analyses were implemented to evaluate any associations between degrees of reporting (measured by the number of items positively answered) and journal impact factor (IF), presence of meta-analysis, and number of citations of the systematic review in Google Scholar. Five hundred and thirty systematic reviews were identified. Following our 12 criteria, none of the systematic reviews had complete reporting of the search strategies and selection process. Eight (1.5%) systematic reviews reported the list of excluded articles (with reasons for exclusion) after title and abstract assessment. Systematic reviews with more positive answers to the criteria were significantly associated with higher journal IF, number of citations, and inclusion of meta-analysis. Search strategies and primary study selection process in systematic reviews published in MEDLINE-indexed dental journals may not be fully reproducible. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Reproducibility and responsiveness of quality of life assessment and six minute walk test in elderly heart failure patients.

    PubMed

    O'Keeffe, S T; Lye, M; Donnellan, C; Carmichael, D N

    1998-10-01

    To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Longitudinal within patient study. 60 patients with heart failure (mean age 82 years) attending a geriatric outpatient clinic, 45 of whom underwent a repeat assessment three to eight weeks later. Subjects underwent a standardised six minute walk test and completed the chronic heart failure questionnaire (CHQ), a heart failure specific quality of life questionnaire. Intraclass correlation coefficients (ICC) were calculated using a random effects one way analysis of variance as a measure of reproducibility. Guyatt's responsiveness coefficient and effect sizes were calculated as measures of responsiveness to change. 24 patients reported no major change in cardiac status, while seven had deteriorated and 14 had improved between the two clinic visits. Reproducibility was satisfactory (ICC > 0.75) for the six minute walk test, for the total CHQ score, and for the dyspnoea, fatigue, and emotion domains of the CHQ. Effect sizes for all measures were large (> 0.8), and responsiveness coefficients were very satisfactory (> 0.7). Effect sizes for detecting deterioration were greater than those for detecting improvement. Quality of life assessment and a six minute walk test are reproducible and responsive measures of cardiac status in frail, very elderly patients with heart failure.

  16. Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasma

    PubMed Central

    Addona, Terri A; Abbatiello, Susan E; Schilling, Birgit; Skates, Steven J; Mani, D R; Bunk, David M; Spiegelman, Clifford H; Zimmerman, Lisa J; Ham, Amy-Joan L; Keshishian, Hasmik; Hall, Steven C; Allen, Simon; Blackman, Ronald K; Borchers, Christoph H; Buck, Charles; Cardasis, Helene L; Cusack, Michael P; Dodder, Nathan G; Gibson, Bradford W; Held, Jason M; Hiltke, Tara; Jackson, Angela; Johansen, Eric B; Kinsinger, Christopher R; Li, Jing; Mesri, Mehdi; Neubert, Thomas A; Niles, Richard K; Pulsipher, Trenton C; Ransohoff, David; Rodriguez, Henry; Rudnick, Paul A; Smith, Derek; Tabb, David L; Tegeler, Tony J; Variyath, Asokan M; Vega-Montoto, Lorenzo J; Wahlander, Åsa; Waldemarson, Sofia; Wang, Mu; Whiteaker, Jeffrey R; Zhao, Lei; Anderson, N Leigh; Fisher, Susan J; Liebler, Daniel C; Paulovich, Amanda G; Regnier, Fred E; Tempst, Paul; Carr, Steven A

    2010-01-01

    Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low µg/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma. PMID:19561596

  17. The reliability of clinical decisions based on the cervical vertebrae maturation staging method.

    PubMed

    Sohrabi, Aydin; Babay Ahari, Sahar; Moslemzadeh, Hossein; Rafighi, Ali; Aghazadeh, Zahra

    2016-02-01

    Of the various techniques used to determine the optimum timing for growth modification treatments, the cervical vertebrae maturation method has great advantages, including validity and no need for extra X-ray exposure. Recently, the reproducibility of this method has been questioned. The aim of this study was to investigate the cause of poor reproducibility of this method and to assess the reproducibility of the clinical decisions made based on it. Seventy lateral cephalograms of Iranian patients aged 9‒15 years were observed twice by five experienced orthodontists. In addition to determining the developmental stage, each single parameter involved in this method was assessed in terms of inter- and intra-observer reproducibility. In order to evaluate the reproducibility of clinical decisions based on this method, cervical vertebrae maturation staging (CVMS) I and II were considered as phase 1 and CVMS IV and V were considered as phase 3. By considering the clinical approach of the CVMS method, inter-observer reproducibility of this method increased from 0.48 to 0.61 (moderate to substantial) and intra-observer reproducibility enhanced from 0.72 to 0.74. 1. Complete visualization of the first four cervical vertebrae was an inclusion criterion, which also limits the clinical application of CVMS method. 2. These results can be generalized when determining growth modification treatments solely for Class II patients. Difficulty in determining the morphology of C3 and C4 leads to poor reproducibility of the CVMS method. Despite this, it has acceptable reproducibility in determining the timing of functional treatment for Class II patients. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Hepatocellular carcinoma: short-term reproducibility of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0T.

    PubMed

    Kakite, Suguru; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Facciuto, Marcelo; Donnerhack, Claudia; Taouli, Bachir

    2015-01-01

    To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC. © 2014 Wiley Periodicals, Inc.

  19. Creating an Optimal 3D Printed Model for Temporal Bone Dissection Training.

    PubMed

    Takahashi, Kuniyuki; Morita, Yuka; Ohshima, Shinsuke; Izumi, Shuji; Kubota, Yamato; Yamamoto, Yutaka; Takahashi, Sugata; Horii, Arata

    2017-07-01

    Making a 3-dimensional (3D) temporal bone model is simple using a plaster powder bed and an inkjet printer. However, it is difficult to reproduce air-containing spaces and precise middle ear structures. The objective of this study was to overcome these problems and create a temporal bone model that would be useful both as a training tool and for preoperative simulation. Drainage holes were made to remove excess materials from air-containing spaces, ossicle ligaments were manually changed to bony structures, and small and/or soft tissue structures were colored differently while designing the 3D models. The outcomes were evaluated by 3 procedures: macroscopic and endoscopic inspection of the model, comparison of computed tomography (CT) images of the model to the original CT, and assessment of tactile sensation and reproducibility by 20 surgeons performing surgery on the model. Macroscopic and endoscopic inspection, CT images, and assessment by surgeons were in agreement in terms of reproducibility of model structures. Most structures could be reproduced, but the stapes, tympanic sinus, and mastoid air cells were unsatisfactory. Perioperative tactile sensation of the model was excellent. Although this model still does not embody perfect reproducibility, it proved sufficiently practical for use in surgical training.

  20. Reproducibility and validity of a food frequency questionnaire in assessing dietary intakes of low-income Caucasian postpartum women living in Sheffield, United Kingdom.

    PubMed

    Mouratidou, Theodora; Ford, Fiona A; Fraser, Robert B

    2011-04-01

    The aim of this study was to examine the reproducibility and validity of a semi-quantitative food frequency questionnaire (FFQ) for assessing dietary intakes of low-income, Caucasian, English-speaking, postpartum women living in Sheffield, United Kingdom. Data was obtained from a cross-sectional sample of the 'Healthy Start' study; a population-based survey of mothers and infants. Participants completed two FFQs at 4 and 8 weeks postpartum. Measures from 24-hour dietary recalls (24HDRs) were collected at 4, 6, 8 and 12 weeks postpartum. In the reproducibility study, crude Pearson's correlation coefficients ranged from 0.40 (riboflavin) to 0.73 (thiamine), mean value 0.54. In the validation study, crude Pearson correlation coefficients between the FFQ and the measures from the 24HDRs ranged from 0.10 (B12) to 0.55 (manganese), mean value 0.34. Energy-adjustments and corrections for attenuation had no significant effect on the strength of the correlation both observed in the reproducibility and validity study. On average, 68% of the participants were classified correctly, and 3% were misclassified into the extreme opposite quintile of the distribution. The authors conclude that the questionnaire performed well for the majority of nutrients examined and that is a valid tool for ranking individuals according to nutrient distribution. © 2009 Blackwell Publishing Ltd.

  1. Assessing the reproducibility of discriminant function analyses

    PubMed Central

    Andrew, Rose L.; Albert, Arianne Y.K.; Renaut, Sebastien; Rennison, Diana J.; Bock, Dan G.

    2015-01-01

    Data are the foundation of empirical research, yet all too often the datasets underlying published papers are unavailable, incorrect, or poorly curated. This is a serious issue, because future researchers are then unable to validate published results or reuse data to explore new ideas and hypotheses. Even if data files are securely stored and accessible, they must also be accompanied by accurate labels and identifiers. To assess how often problems with metadata or data curation affect the reproducibility of published results, we attempted to reproduce Discriminant Function Analyses (DFAs) from the field of organismal biology. DFA is a commonly used statistical analysis that has changed little since its inception almost eight decades ago, and therefore provides an opportunity to test reproducibility among datasets of varying ages. Out of 100 papers we initially surveyed, fourteen were excluded because they did not present the common types of quantitative result from their DFA or gave insufficient details of their DFA. Of the remaining 86 datasets, there were 15 cases for which we were unable to confidently relate the dataset we received to the one used in the published analysis. The reasons ranged from incomprehensible or absent variable labels, the DFA being performed on an unspecified subset of the data, or the dataset we received being incomplete. We focused on reproducing three common summary statistics from DFAs: the percent variance explained, the percentage correctly assigned and the largest discriminant function coefficient. The reproducibility of the first two was fairly high (20 of 26, and 44 of 60 datasets, respectively), whereas our success rate with the discriminant function coefficients was lower (15 of 26 datasets). When considering all three summary statistics, we were able to completely reproduce 46 (65%) of 71 datasets. While our results show that a majority of studies are reproducible, they highlight the fact that many studies still are not the carefully curated research that the scientific community and public expects. PMID:26290793

  2. [Reproducibility of subjective refraction measurement].

    PubMed

    Grein, H-J; Schmidt, O; Ritsche, A

    2014-11-01

    Reproducibility of subjective refraction measurement is limited by various factors. The main factors affecting reproducibility include the characteristics of the measurement method and of the subject and the examiner. This article presents the results of a study on this topic, focusing on the reproducibility of subjective refraction measurement in healthy eyes. The results of previous studies are not all presented in the same way by the respective authors and cannot be fully standardized without consulting the original scientific data. To the extent that they are comparable, the results of our study largely correspond largely with those of previous investigations: During repeated subjective refraction measurement, 95% of the deviation from the mean value was approximately ±0.2 D to ±0.65 D for the spherical equivalent and cylindrical power. The reproducibility of subjective refraction measurement in healthy eyes is limited, even under ideal conditions. Correct assessment of refraction results is only feasible after identifying individual variability. Several measurements are required. Refraction cannot be measured without a tolerance range. The English full-text version of this article is available at SpringerLink (under supplemental).

  3. Transferability and within- and between-laboratory reproducibilities of EpiSensA for predicting skin sensitization potential in vitro: A ring study in three laboratories.

    PubMed

    Mizumachi, Hideyuki; Sakuma, Megumi; Ikezumi, Mayu; Saito, Kazutoshi; Takeyoshi, Midori; Imai, Noriyasu; Okutomi, Hiroko; Umetsu, Asami; Motohashi, Hiroko; Watanabe, Mika; Miyazawa, Masaaki

    2018-05-03

    The epidermal sensitization assay (EpiSensA) is an in vitro skin sensitization test method based on gene expression of four markers related to the induction of skin sensitization; the assay uses commercially available reconstructed human epidermis. EpiSensA has exhibited an accuracy of 90% for 72 chemicals, including lipophilic chemicals and pre-/pro-haptens, when compared with the results of the murine local lymph node assay. In this work, a ring study was performed by one lead and two naive laboratories to evaluate the transferability, as well as within- and between-laboratory reproducibilities, of EpiSensA. Three non-coded chemicals (two lipophilic sensitizers and one non-sensitizer) were tested for the assessment of transferability and 10 coded chemicals (seven sensitizers and three non-sensitizers, including four lipophilic chemicals) were tested for the assessment of reproducibility. In the transferability phase, the non-coded chemicals (two sensitizers and one non-sensitizer) were correctly classified at the two naive laboratories, indicating that the EpiSensA protocol was transferred successfully. For the within-laboratory reproducibility, the data generated with three coded chemicals tested in three independent experiments in each laboratory gave consistent predictions within laboratories. For the between-laboratory reproducibility, 9 of the 10 coded chemicals tested once in each laboratory provided consistent predictions among the three laboratories. These results suggested that EpiSensA has good transferability, as well as within- and between-laboratory reproducibility. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Scan-rescan reproducibility of diastolic left ventricular kinetic energy, viscous energy loss and vorticity assessment using 4D flow MRI: analysis in healthy subjects.

    PubMed

    Kamphuis, Vivian P; Westenberg, Jos J M; van der Palen, Roel L F; van den Boogaard, Pieter J; van der Geest, Rob J; de Roos, Albert; Blom, Nico A; Roest, Arno A W; Elbaz, Mohammed S M

    2018-01-05

    The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. EL index was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, EL index and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. EL index showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless EL index , which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.

  5. Validation of a simplified food frequency questionnaire for the assessment of dietary habits in Iranian adults: Isfahan Healthy Heart Program, Iran.

    PubMed

    Mohammadifard, Noushin; Sajjadi, Firouzeh; Maghroun, Maryam; Alikhasi, Hassan; Nilforoushzadeh, Farzaneh; Sarrafzadegan, Nizal

    2015-03-01

    Dietary assessment is the first step of dietary modification in community-based interventional programs. This study was performed to validate a simple food frequency questionnaire (SFFQ) for assessment of selected food items in epidemiological studies with a large sample size as well as community trails. This validation study was carried out on 264 healthy adults aged ≥ 41 years old living in 3 district central of Iran, including Isfahan, Najafabad, and Arak. Selected food intakes were assessed using a 48-item food frequency questionnaire (FFQ). The FFQ was interviewer-administered, which was completed twice; at the beginning of the study and 2 weeks thereafter. The validity of this SFFQ was examined compared to estimated amount by single 24 h dietary recall and 2 days dietary record. Validation of the FFQ was determined using Spearman correlation coefficients between daily frequency consumption of food groups as assessed by the FFQ and the qualitative amount of daily food groups intake accessed by dietary reference method was applied to evaluate validity. Intraclass correlation coefficients (ICC) were used to determine the reproducibility. Spearman correlation coefficient between the estimated amount of food groups intake by examined and reference methods ranged from 0.105 (P = 0.378) in pickles to 0.48 (P < 0.001) in plant protein. ICC for reproducibility of FFQ were between 0.47-0.69 in different food groups (P < 0.001). The designed SFFQ has a good relative validity and reproducibility for assessment of selected food groups intake. Thus, it can serve as a valid tool in epidemiological studies and clinical trial with large participants.

  6. Within-person reproducibility of urinary bisphenol A and phthalate metabolites over a 1 to 3 year period among women in the Nurses’ Health Studies: a prospective cohort study

    PubMed Central

    2013-01-01

    Background Associations of bisphenol A and phthalates with chronic disease health outcomes are increasingly being investigated in epidemiologic studies. The majority of previous studies of within-person variability in urinary bisphenol A and phthalate metabolite concentrations have focused on reproducibility over short time periods. Long-term reproducibility data are needed to assess the potential usefulness of these biomarkers for prospective studies, particularly those examining risk of diseases with long latency periods. Low within-person reproducibility may attenuate relative risk estimates and reduce statistical power to detect associations with disease. Therefore, we assessed within-person reproducibility of bisphenol A, eight phthalate metabolites, and phthalic acid in spot urine samples over 1 to 3 years among women enrolled in two large cohort studies. Methods Women in the Nurses’ Health Study and Nurses’ Health Study II provided two spot urine samples, 1 to 3 years apart (n = 80 women for analyses of bisphenol A; n = 40 women for analyses of phthalate metabolites; n = 34 women for analyses of phthalic acid). To measure within-person reproducibility, we calculated Spearman rank correlation coefficients and intraclass correlation coefficients for creatinine-adjusted concentrations of bisphenol A, phthalate metabolites, and phthalic acid. Results Over 1 to 3 years, within-person variability of bisphenol A was high relative to total variability (intraclass correlation coefficient = 0.14) and rankings of bisphenol A levels between time-points were weakly correlated (Spearman correlation = 0.19). Seven of the eight phthalate metabolites and phthalic acid demonstrated moderate within-person stability over time (Spearman correlation or intraclass correlation coefficient = 0.39-0.55). Restricting analyses to first-morning urine samples did not alter results. Conclusions Single measurements of bisphenol A in spot urine samples were highly variable within women over 1 to 3 years, indicating that investigation of associations between a single urinary bisphenol A measurement and disease risk may be challenging in epidemiologic studies. The majority of urinary phthalate metabolites and phthalic acid appeared moderately reproducible within women over time, suggesting single measurements may be useful in epidemiologic studies, although observed relative risks can be substantially attenuated. PMID:24034517

  7. Within-person reproducibility of urinary bisphenol A and phthalate metabolites over a 1 to 3 year period among women in the Nurses' Health Studies: a prospective cohort study.

    PubMed

    Townsend, Mary K; Franke, Adrian A; Li, Xingnan; Hu, Frank B; Eliassen, A Heather

    2013-09-13

    Associations of bisphenol A and phthalates with chronic disease health outcomes are increasingly being investigated in epidemiologic studies. The majority of previous studies of within-person variability in urinary bisphenol A and phthalate metabolite concentrations have focused on reproducibility over short time periods. Long-term reproducibility data are needed to assess the potential usefulness of these biomarkers for prospective studies, particularly those examining risk of diseases with long latency periods. Low within-person reproducibility may attenuate relative risk estimates and reduce statistical power to detect associations with disease. Therefore, we assessed within-person reproducibility of bisphenol A, eight phthalate metabolites, and phthalic acid in spot urine samples over 1 to 3 years among women enrolled in two large cohort studies. Women in the Nurses' Health Study and Nurses' Health Study II provided two spot urine samples, 1 to 3 years apart (n = 80 women for analyses of bisphenol A; n = 40 women for analyses of phthalate metabolites; n = 34 women for analyses of phthalic acid). To measure within-person reproducibility, we calculated Spearman rank correlation coefficients and intraclass correlation coefficients for creatinine-adjusted concentrations of bisphenol A, phthalate metabolites, and phthalic acid. Over 1 to 3 years, within-person variability of bisphenol A was high relative to total variability (intraclass correlation coefficient = 0.14) and rankings of bisphenol A levels between time-points were weakly correlated (Spearman correlation = 0.19). Seven of the eight phthalate metabolites and phthalic acid demonstrated moderate within-person stability over time (Spearman correlation or intraclass correlation coefficient = 0.39-0.55). Restricting analyses to first-morning urine samples did not alter results. Single measurements of bisphenol A in spot urine samples were highly variable within women over 1 to 3 years, indicating that investigation of associations between a single urinary bisphenol A measurement and disease risk may be challenging in epidemiologic studies. The majority of urinary phthalate metabolites and phthalic acid appeared moderately reproducible within women over time, suggesting single measurements may be useful in epidemiologic studies, although observed relative risks can be substantially attenuated.

  8. Measures of low back function: a review of reproducibility studies.

    PubMed

    Essendrop, Morten; Maul, Irina; Läubli, Thomas; Riihimäki, Hilkka; Schibye, Bente

    2002-05-01

    The objective of the present study was to make a systematic literature review with preset quality criteria concerning reproducibility of the tests of the low back regarding strength, endurance and range of motion. Literature in Medline and local databases was reviewed for articles concerning the reproducibility of strength, endurance, and range of motion measurements. Measures of low back function are widely used, and are important for both clinical and research purposes in relation to low back problems. A review of the reproducibility of these tests has not previously been made. After extensive discussion among all the authors, general evaluation parameters were defined for the quality assessment. Every study was graded from 0 to 2 for each parameter. Parameters evaluated were: number of subjects, subject description, method description, test/retest interval, description of results, and statistics. The literature search revealed a total of 79 studies. Most studies suffered from methodological weaknesses and only eleven studies received ten or more quality points (maximum 14). The results from the highest graded studies are highlighted. It may be concluded that there is a considerable lack of information about the reproducibility of functional measures for the low back, and therefore a recommendation for consensus is difficult. However, most tests performed in the sagittal plane are reliable for use on groups. Measures of low back function are thought to be of great importance for clinicians, and low back researchers in general. A review of reproducibility will be helpful both as a survey of tests, and to provide information on the usefulness in relation to the level of reproducibility.

  9. Reproducibility assessment of brain responses to visual food stimuli in adults with overweight and obesity

    PubMed Central

    Sayer, R Drew; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W

    2016-01-01

    Objective The brain’s reward system influences ingestive behavior and subsequently, obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. We sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. Methods A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n=16) and men (n=12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the 2 testing days. Results Mean fasting-state brain responses on Day 2 were reduced compared to Day 1 in the left insula and right amygdala, but mean Day 1 and Day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. Conclusion fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility, but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. PMID:27542906

  10. Quantitative assessment of muscle in dogs using a vertebral epaxial muscle score.

    PubMed

    Freeman, Lisa M; Sutherland-Smith, James; Prantil, Lori R; Sato, Amy F; Rush, John E; Barton, Bruce A

    2017-10-01

    Muscle loss associated with disease (cachexia) or with aging (sarcopenia) is common in dogs, but clinically relevant methods for quantifying muscle loss are needed. We previously validated an ultrasound method of quantifying muscle size in dogs in a single breed. The goal of this study was to assess the variability and reproducibility of the Vertebral Epaxial Muscle Score (VEMS) in other dog breeds. Static ultrasound images were obtained from 38 healthy, neutered dogs of 5 different breeds between 1- and 5-years-old. The maximal transverse right epaxial muscle height and area at the level of the 13th thoracic vertebra (T13) were measured. Length of the 4th thoracic vertebra (T4) was measured from thoracic radiography. Ratios of the muscle height and area to vertebral length (height/T4 and area/T4, respectively) were calculated to account for differences in body size among breeds. Reproducibility testing was performed on 2 dogs of each breed (26% of the total) to determine intra- and inter-investigator reproducibility, as well as intra-class correlation. Mean height/T4 = 1.02 ± 0.18 and mean area/T4 = 3.32 ± 1.68. There was no significant difference for height/T4 ( P = 0.10) among breeds, but breeds were significantly different in area/T4 ( P < 0.001). Intra-class correlation ranged from 0.80 to 0.99. Testing showed better reproducibility for height/T4 compared to area/T4. The VEMS using height/T4 was valid and reproducible for healthy dogs of different sizes and body conformations. Studies assessing this technique in dogs with congestive heart failure and other diseases associated with muscle loss are warranted.

  11. Quantitative assessment of muscle in dogs using a vertebral epaxial muscle score

    PubMed Central

    Freeman, Lisa M.; Sutherland-Smith, James; Prantil, Lori R.; Sato, Amy F.; Rush, John E.; Barton, Bruce A.

    2017-01-01

    Muscle loss associated with disease (cachexia) or with aging (sarcopenia) is common in dogs, but clinically relevant methods for quantifying muscle loss are needed. We previously validated an ultrasound method of quantifying muscle size in dogs in a single breed. The goal of this study was to assess the variability and reproducibility of the Vertebral Epaxial Muscle Score (VEMS) in other dog breeds. Static ultrasound images were obtained from 38 healthy, neutered dogs of 5 different breeds between 1- and 5-years-old. The maximal transverse right epaxial muscle height and area at the level of the 13th thoracic vertebra (T13) were measured. Length of the 4th thoracic vertebra (T4) was measured from thoracic radiography. Ratios of the muscle height and area to vertebral length (height/T4 and area/T4, respectively) were calculated to account for differences in body size among breeds. Reproducibility testing was performed on 2 dogs of each breed (26% of the total) to determine intra- and inter-investigator reproducibility, as well as intra-class correlation. Mean height/T4 = 1.02 ± 0.18 and mean area/T4 = 3.32 ± 1.68. There was no significant difference for height/T4 (P = 0.10) among breeds, but breeds were significantly different in area/T4 (P < 0.001). Intra-class correlation ranged from 0.80 to 0.99. Testing showed better reproducibility for height/T4 compared to area/T4. The VEMS using height/T4 was valid and reproducible for healthy dogs of different sizes and body conformations. Studies assessing this technique in dogs with congestive heart failure and other diseases associated with muscle loss are warranted. PMID:29081582

  12. Methods and reproducibility of grading optimized digital color fundus photographs in the Age-Related Eye Disease Study 2 (AREDS2 Report Number 2).

    PubMed

    Danis, Ronald P; Domalpally, Amitha; Chew, Emily Y; Clemons, Traci E; Armstrong, Jane; SanGiovanni, John Paul; Ferris, Frederick L

    2013-07-08

    To establish continuity with the grading procedures and outcomes from the historical data of the Age-Related Eye Disease Study (AREDS), color photographic imaging and evaluation procedures for the assessment of age-related macular degeneration (AMD) were modified for digital imaging in the AREDS2. The reproducibility of the grading of index AMD lesion components and for the AREDS severity scale was tested at the AREDS2 reading center. Digital color stereoscopic fundus photographs from 4203 AREDS2 subjects collected at baseline and annual follow-up visits were optimized for tonal balance and graded according to a standard protocol slightly modified from AREDS. The reproducibility of digital grading of AREDS2 images was assessed by reproducibility exercises, temporal drift (regrading a subset of baseline annually, n = 88), and contemporaneous masked regrading (ongoing, monthly regrade on 5% of submissions, n = 1335 eyes). In AREDS2, 91% and 96% of images received replicate grades within two steps of the baseline value on the AREDS severity scale for temporal drift and contemporaneous assessment, respectively (weighted Kappa of 0.73 and 0.76). Historical data for temporal drift in replicate gradings on the AREDS film-based images were 88% within two steps (weighted Kappa = 0.88). There was no difference in AREDS2-AREDS concordance for temporal drift (exact P = 0.57). Digital color grading has nearly the same reproducibility as historical film grading. There is substantial agreement for testing the predictive utility of the AREDS severity scale in AREDS2 as a clinical trial outcome. (ClinicalTrials.gov number, NCT00345176.)

  13. Angiographic core laboratory reproducibility analyses: implications for planning clinical trials using coronary angiography and left ventriculography end-points.

    PubMed

    Steigen, Terje K; Claudio, Cheryl; Abbott, David; Schulzer, Michael; Burton, Jeff; Tymchak, Wayne; Buller, Christopher E; John Mancini, G B

    2008-06-01

    To assess reproducibility of core laboratory performance and impact on sample size calculations. Little information exists about overall reproducibility of core laboratories in contradistinction to performance of individual technicians. Also, qualitative parameters are being adjudicated increasingly as either primary or secondary end-points. The comparative impact of using diverse indexes on sample sizes has not been previously reported. We compared initial and repeat assessments of five quantitative parameters [e.g., minimum lumen diameter (MLD), ejection fraction (EF), etc.] and six qualitative parameters [e.g., TIMI myocardial perfusion grade (TMPG) or thrombus grade (TTG), etc.], as performed by differing technicians and separated by a year or more. Sample sizes were calculated from these results. TMPG and TTG were also adjudicated by a second core laboratory. MLD and EF were the most reproducible, yielding the smallest sample size calculations, whereas percent diameter stenosis and centerline wall motion require substantially larger trials. Of the qualitative parameters, all except TIMI flow grade gave reproducibility characteristics yielding sample sizes of many 100's of patients. Reproducibility of TMPG and TTG was only moderately good both within and between core laboratories, underscoring an intrinsic difficulty in assessing these. Core laboratories can be shown to provide reproducibility performance that is comparable to performance commonly ascribed to individual technicians. The differences in reproducibility yield huge differences in sample size when comparing quantitative and qualitative parameters. TMPG and TTG are intrinsically difficult to assess and conclusions based on these parameters should arise only from very large trials.

  14. Relative validity and reproducibility of a quantitative FFQ for assessing nutrient intakes of vegetarians in Taiwan.

    PubMed

    Chiu, Tina H T; Huang, Hui-Ya; Chen, Kuan-Ju; Wu, Yu-R U; Chiu, Jason P C; Li, Yi-Hwei; Chiu, Brian C-H; Lin, Chin-Lon; Lin, Ming-Nan

    2014-07-01

    To assess the relative validity and reproducibility of the quantitative FFQ used in the Tzu Chi Health Study (TCHS). The reproducibility was evaluated by comparing the baseline FFQ with the 2-year follow-up FFQ. The validity was evaluated by comparing the baseline FFQ with 3 d dietary records and biomarkers (serum folate and vitamin B12). Median comparison, cross-classification and Spearman correlation with and without energy adjustment and deattenuation for day-to-day variation were assessed. TCHS is a prospective cohort containing a high proportion of true vegetarians and part-time vegetarians (regularly consuming a vegetarian diet without completely avoiding meat). Subsets of 103, seventy-eight and 1528 TCHS participants were included in the reproducibility, dietary record-validity and biomarker-validity studies, respectively. Correlations assessing the reproducibility for repeat administrations of the FFQ were in the range of 0·46-0·65 for macronutrients and 0·35-0·67 for micronutrients; the average same quartile agreement was 40%. The correlation between FFQ and biomarkers was 0·41 for both vitamin B12 and folate. Moderate to good correlations between the baseline FFQ and dietary records were found for energy, protein, carbohydrate, saturated and monounsaturated fat, fibre, vitamin C, vitamin A, K, Ca, Mg, P, Fe and Zn (average crude correlation: 0·47 (range: 0·37-0·66); average energy-adjusted correlation: 0·43 (range: 0·38-0·55); average energy-adjusted deattenuated correlation: 0·50 (range: 0·44-0·66)) with same quartile agreement rate of 39% (range: 35-45%), while misclassification to the extreme quartile was rare (average: 4% (range: 0-6%)). The FFQ is a reliable and valid tool to rank relative intake of major nutrients for TCHS participants.

  15. Ultrasound functional imaging in an ex vivo beating porcine heart platform

    NASA Astrophysics Data System (ADS)

    Petterson, Niels J.; Fixsen, Louis S.; Rutten, Marcel C. M.; Pijls, Nico H. J.; van de Vosse, Frans N.; Lopata, Richard G. P.

    2017-12-01

    In recent years, novel ultrasound functional imaging (UFI) techniques have been introduced to assess cardiac function by measuring, e.g. cardiac output (CO) and/or myocardial strain. Verification and reproducibility assessment in a realistic setting remain major issues. Simulations and phantoms are often unrealistic, whereas in vivo measurements often lack crucial hemodynamic parameters or ground truth data, or suffer from the large physiological and clinical variation between patients when attempting clinical validation. Controlled validation in certain pathologies is cumbersome and often requires the use of lab animals. In this study, an isolated beating pig heart setup was adapted and used for performance assessment of UFI techniques such as volume assessment and ultrasound strain imaging. The potential of performing verification and reproducibility studies was demonstrated. For proof-of-principle, validation of UFI in pathological hearts was examined. Ex vivo porcine hearts (n  =  6, slaughterhouse waste) were resuscitated and attached to a mock circulatory system. Radio frequency ultrasound data of the left ventricle were acquired in five short axis views and one long axis view. Based on these slices, the CO was measured, where verification was performed using flow sensor measurements in the aorta. Strain imaging was performed providing radial, circumferential and longitudinal strain to assess reproducibility and inter-subject variability under steady conditions. Finally, strains in healthy hearts were compared to a heart with an implanted left ventricular assist device, simulating a failing, supported heart. Good agreement between ultrasound and flow sensor based CO measurements was found. Strains were highly reproducible (intraclass correlation coefficients  >0.8). Differences were found due to biological variation and condition of the hearts. Strain magnitude and patterns in the assisted heart were available for different pump action, revealing large changes compared to the normal condition. The setup provides a valuable benchmarking platform for UFI techniques. Future studies will include work on different pathologies and other means of measurement verification.

  16. Reproducibility over a 1-month period of 1H-MR spectroscopic imaging NAA/Cr ratios in clinically stable multiple sclerosis patients.

    PubMed

    Mostert, J P; Blaauw, Y; Koch, M W; Kuiper, A J; Hoogduin, J M; De Keyser, J

    2008-08-01

    N-acetylaspartate/creatine (NAA/Cr) ratios, assessed with proton magnetic resonance spectroscopy, are increasingly used as a surrogate marker for axonal dysfunction and degeneration in multiple sclerosis (MS). The purpose of this study was to test short-time reproducibility of NAA/Cr ratios in patients with clinically stable MS. In 35 MS patients we analysed NAA/Cr ratios obtained with (1)H-MR spectroscopic imaging at the centrum semiovale either with lateral ventricles partially included (group 1; n=15) or more cranially with no ventricles included (group 2; n=20). To test short-term reproducibility of the NAA/Cr measurements, patients were scanned twice 4 weeks apart. We determined mean NAA/Cr and Cho/Cr ratios of 12 grey matter and 24 white matter voxels. Mean NAA/Cr ratios of both the white and grey matter did not change after 4 weeks. Overall 4-week reproducibility of the NAA/Cr ratio, expressed as coefficient of variation, was 4.8% for grey matter and 3.5% for white matter. Reproducibility of cranial scanning of the ventricles was slightly better than with cerebrospinal fluid included. Our study shows good short-term reproducibility of NAA/Cr ratio measurements in the centrum semiovale, which supports the reliability of this technique for longitudinal studies.

  17. Using prediction markets to estimate the reproducibility of scientific research.

    PubMed

    Dreber, Anna; Pfeiffer, Thomas; Almenberg, Johan; Isaksson, Siri; Wilson, Brad; Chen, Yiling; Nosek, Brian A; Johannesson, Magnus

    2015-12-15

    Concerns about a lack of reproducibility of statistically significant results have recently been raised in many fields, and it has been argued that this lack comes at substantial economic costs. We here report the results from prediction markets set up to quantify the reproducibility of 44 studies published in prominent psychology journals and replicated in the Reproducibility Project: Psychology. The prediction markets predict the outcomes of the replications well and outperform a survey of market participants' individual forecasts. This shows that prediction markets are a promising tool for assessing the reproducibility of published scientific results. The prediction markets also allow us to estimate probabilities for the hypotheses being true at different testing stages, which provides valuable information regarding the temporal dynamics of scientific discovery. We find that the hypotheses being tested in psychology typically have low prior probabilities of being true (median, 9%) and that a "statistically significant" finding needs to be confirmed in a well-powered replication to have a high probability of being true. We argue that prediction markets could be used to obtain speedy information about reproducibility at low cost and could potentially even be used to determine which studies to replicate to optimally allocate limited resources into replications.

  18. Using prediction markets to estimate the reproducibility of scientific research

    PubMed Central

    Dreber, Anna; Pfeiffer, Thomas; Almenberg, Johan; Isaksson, Siri; Wilson, Brad; Chen, Yiling; Nosek, Brian A.; Johannesson, Magnus

    2015-01-01

    Concerns about a lack of reproducibility of statistically significant results have recently been raised in many fields, and it has been argued that this lack comes at substantial economic costs. We here report the results from prediction markets set up to quantify the reproducibility of 44 studies published in prominent psychology journals and replicated in the Reproducibility Project: Psychology. The prediction markets predict the outcomes of the replications well and outperform a survey of market participants’ individual forecasts. This shows that prediction markets are a promising tool for assessing the reproducibility of published scientific results. The prediction markets also allow us to estimate probabilities for the hypotheses being true at different testing stages, which provides valuable information regarding the temporal dynamics of scientific discovery. We find that the hypotheses being tested in psychology typically have low prior probabilities of being true (median, 9%) and that a “statistically significant” finding needs to be confirmed in a well-powered replication to have a high probability of being true. We argue that prediction markets could be used to obtain speedy information about reproducibility at low cost and could potentially even be used to determine which studies to replicate to optimally allocate limited resources into replications. PMID:26553988

  19. Reproducibility of electronic tooth colour measurements.

    PubMed

    Ratzmann, Anja; Klinke, Thomas; Schwahn, Christian; Treichel, Anja; Gedrange, Tomasz

    2008-10-01

    Clinical methods of investigation, such as tooth colour determination, should be simple, quick and reproducible. The determination of tooth colours usually relies upon manual comparison of a patient's tooth colour with a colour ring. After some days, however, measurement results frequently lack unequivocal reproducibility. This study aimed to examine an electronic method for reliable colour measurement. The colours of the teeth 14 to 24 were determined by three different examiners in 10 subjects using the colour measuring device Shade Inspector. In total, 12 measurements per tooth were taken. Two measurement time points were scheduled to be taken, namely at study onset (T(1)) and after 6 months (T(2)). At either time point, two measurement series per subject were taken by the different examiners at 2-week intervals. The inter-examiner and intra-examiner agreement of the measurement results was assessed. The concordance for lightness and colour intensity (saturation) was represented by the intra-class correlation coefficient. The categorical variable colour shade (hue) was assessed using the kappa statistic. The study results show that tooth colour can be measured independently of the examiner. Good agreement was found between the examiners.

  20. Evaluation of a short Food Frequency Questionnaire to assess cardiovascular disease-related diet and lifestyle factors

    PubMed Central

    Svendsen, Karianne; Henriksen, Hege Berg; Østengen, Beate; Jacobs, David R.; Telle-Hansen, Vibeke H.; Carlsen1, Monica H.; Retterstøl, Kjetil

    2018-01-01

    Background The Vascular lifestyle-Intervention and Screening in phArmacies (VISA) study investigates diet and lifestyle factors associated with risk of cardiovascular disease (CVD). As part of the study methodology, a short Food Frequency Questionnaire (FFQ), the VISA-FFQ, was adapted from the Norwegian NORDIET-FFQ. Objective The aim of this study was to evaluate the VISA-FFQ and its ability to estimate intakes of foods and lifestyle factors in screening for elevated risk of CVD. The evaluation included assessment of relative validity of intake of milk fat and assessment of reproducibility of several foods and lifestyle factors. Design Relative validity of milk fat estimated from the VISA-FFQ was assessed in 307 participants by comparing estimated dietary intake of the fatty acids pentadecanoic acid (15:0) and heptadecanoic acid (17:0), from milk fat with whole blood biomarkers 15:0 and 17:0. Reproducibility was evaluated in 122 participants by comparing consistency in intakes of different foods and lifestyle factors reported by the VISA-FFQ and administered twice with a 4-week interval. Results Dietary 15:0 milk fat estimated from the VISA-FFQ correlated positively with whole blood 15:0 (r = 0.32, P < 0.05). Men presented higher correlations than women did. Acceptable and consistent reproducibility (r = 0.44–0.94 and no large difference between test and retest) was observed for most beverages, milk products, spreads on bread and meat (all of which included food items categorised into at least two fat categories) and also for eggs, fruits and vegetables, nuts, pasta and rice, dessert/sweets, smoking and physical activity. Reproducibility did not consistently meet a satisfactory standard (r ≤ 0.41 or large difference between test and retest) for unsweetened cereals, fatty fish, cakes, oils, white-, bread, crispbread and rice. Conclusion The validity of the VISA-FFQ was acceptable for intake of milk fat, and there was an overall satisfactory, though variable, reproducibility for intake of several foods and lifestyle factors in the VISA-FFQ. PMID:29720928

  1. Measuring Age-Dependent Myocardial Stiffness across the Cardiac Cycle using MR Elastography: A Reproducibility Study

    PubMed Central

    Wassenaar, Peter A; Eleswarpu, Chethanya N; Schroeder, Samuel A; Mo, Xiaokui; Raterman, Brian D; White, Richard D; Kolipaka, Arunark

    2015-01-01

    Purpose To assess reproducibility in measuring left ventricular (LV) myocardial stiffness in volunteers throughout the cardiac cycle using magnetic resonance elastography (MRE) and to determine its correlation with age. Methods Cardiac MRE (CMRE) was performed on 29 normal volunteers, with ages ranging from 21 to 73 years. For assessing reproducibility of CMRE-derived stiffness measurements, scans were repeated per volunteer. Wave images were acquired throughout the LV myocardium, and were analyzed to obtain mean stiffness during the cardiac cycle. CMRE-derived stiffness values were correlated to age. Results Concordance correlation coefficient revealed good inter-scan agreement with rc of 0.77, with p-value<0.0001. Significantly higher myocardial stiffness was observed during end-systole (ES) compared to end-diastole (ED) across all subjects. Additionally, increased deviation between ES and ED stiffness was observed with increased age. Conclusion CMRE-derived stiffness is reproducible, with myocardial stiffness changing cyclically across the cardiac cycle. Stiffness is significantly higher during ES compared to ED. With age, ES myocardial stiffness increases more than ED, giving rise to an increased deviation between the two. PMID:26010456

  2. Reproducibility of data-driven dietary patterns in two groups of adult Spanish women from different studies.

    PubMed

    Castelló, Adela; Lope, Virginia; Vioque, Jesús; Santamariña, Carmen; Pedraz-Pingarrón, Carmen; Abad, Soledad; Ederra, Maria; Salas-Trejo, Dolores; Vidal, Carmen; Sánchez-Contador, Carmen; Aragonés, Nuria; Pérez-Gómez, Beatriz; Pollán, Marina

    2016-08-01

    The objective of the present study was to assess the reproducibility of data-driven dietary patterns in different samples extracted from similar populations. Dietary patterns were extracted by applying principal component analyses to the dietary information collected from a sample of 3550 women recruited from seven screening centres belonging to the Spanish breast cancer (BC) screening network (Determinants of Mammographic Density in Spain (DDM-Spain) study). The resulting patterns were compared with three dietary patterns obtained from a previous Spanish case-control study on female BC (Epidemiological study of the Spanish group for breast cancer research (GEICAM: grupo Español de investigación en cáncer de mama)) using the dietary intake data of 973 healthy participants. The level of agreement between patterns was determined using both the congruence coefficient (CC) between the pattern loadings (considering patterns with a CC≥0·85 as fairly similar) and the linear correlation between patterns scores (considering as fairly similar those patterns with a statistically significant correlation). The conclusions reached with both methods were compared. This is the first study exploring the reproducibility of data-driven patterns from two studies and the first using the CC to determine pattern similarity. We were able to reproduce the EpiGEICAM Western pattern in the DDM-Spain sample (CC=0·90). However, the reproducibility of the Prudent (CC=0·76) and Mediterranean (CC=0·77) patterns was not as good. The linear correlation between pattern scores was statistically significant in all cases, highlighting its arbitrariness for determining pattern similarity. We conclude that the reproducibility of widely prevalent dietary patterns is better than the reproducibility of more population-specific patterns. More methodological studies are needed to establish an objective measurement and threshold to determine pattern similarity.

  3. Novel Use of the Nintendo Wii Board for Measuring Isometric Lower Limb Strength: A Reproducible and Valid Method in Older Adults.

    PubMed

    Gronbech Jorgensen, Martin; Andersen, Stig; Ryg, Jesper; Masud, Tahir

    2015-01-01

    Portable, low-cost, objective and reproducible assessment of muscle strength in the lower limbs is important as it allows clinicians to precisly track progression of patients undergoing rehabilitation. The Nintendo Wii Balance Board (WBB) is portable, inexpensive, durable, available worldwide, and may serve the above function. The purpose of the study was to evaluate (1) reproducibility and (2) concurrent validity of the WBB for measuring isometric muscle strength in the lower limb. A custom hardware and software was developed to utilize the WBB for assessment of isometric muscle strength. Thirty older adults (69.0 ± 4.2 years of age) were studied on two separate occasions on both the WBB and a stationary isometric dynamometer (SID). On each occasion, three recordings were obtained from each device. For the first recording, means and maximum values were used for further analysis. The test-retest reproducibility was examined using intraclass correlation coefficients (ICC), Standard Error of Measurement (SEM), and limits of agreement (LOA). Bland-Altman plots (BAP) and ICC's were used to explore concurrent validity. No systematic difference between test-retest was detected for the WBB. ICC within-device were between 0.90 and 0.96 and between-devices were from 0.80 to 0.84. SEM ranged for the WBB from 9.7 to 13.9%, and for the SID from 11.9 to 13.1%. LOA ranged for the WBB from 20.3 to 28.7% and for the SID from 24.2 to 26.6%. The BAP showed no relationship between the difference and the mean. A high relative and an acceptable absolute reproducibility combined with a good validity was found for the novel method using the WBB for measuring isometric lower limb strength in older adults. Further research using the WBB for assessing lower limb strength should be conducted in different study-populations.

  4. Reproducibility of Tactile Assessments for Children with Unilateral Cerebral Palsy

    ERIC Educational Resources Information Center

    Auld, Megan Louise; Ware, Robert S.; Boyd, Roslyn Nancy; Moseley, G. Lorimer; Johnston, Leanne Marie

    2012-01-01

    A systematic review identified tactile assessments used in children with cerebral palsy (CP), but their reproducibility is unknown. Sixteen children with unilateral CP and 31 typically developing children (TDC) were assessed 2-4 weeks apart. Test-retest percent agreements within one point for children with unilateral CP (and TDC) were…

  5. Shear wave elastography for breast masses is highly reproducible.

    PubMed

    Cosgrove, David O; Berg, Wendie A; Doré, Caroline J; Skyba, Danny M; Henry, Jean-Pierre; Gay, Joel; Cohen-Bacrie, Claude

    2012-05-01

    To evaluate intra- and interobserver reproducibility of shear wave elastography (SWE) for breast masses. For intraobserver reproducibility, each observer obtained three consecutive SWE images of 758 masses that were visible on ultrasound. 144 (19%) were malignant. Weighted kappa was used to assess the agreement of qualitative elastographic features; the reliability of quantitative measurements was assessed by intraclass correlation coefficients (ICC). For the interobserver reproducibility, a blinded observer reviewed images and agreement on features was determined. Mean age was 50 years; mean mass size was 13 mm. Qualitatively, SWE images were at least reasonably similar for 666/758 (87.9%). Intraclass correlation for SWE diameter, area and perimeter was almost perfect (ICC ≥ 0.94). Intraobserver reliability for maximum and mean elasticity was almost perfect (ICC = 0.84 and 0.87) and was substantial for the ratio of mass-to-fat elasticity (ICC = 0.77). Interobserver agreement was moderate for SWE homogeneity (κ = 0.57), substantial for qualitative colour assessment of maximum elasticity (κ = 0.66), fair for SWE shape (κ = 0.40), fair for B-mode mass margins (κ = 0.38), and moderate for B-mode mass shape (κ = 0.58), orientation (κ = 0.53) and BI-RADS assessment (κ = 0.59). SWE is highly reproducible for assessing elastographic features of breast masses within and across observers. SWE interpretation is at least as consistent as that of BI-RADS ultrasound B-mode features. • Shear wave ultrasound elastography can measure the stiffness of breast tissue • It provides a qualitatively and quantitatively interpretable colour-coded map of tissue stiffness • Intraobserver reproducibility of SWE is almost perfect while intraobserver reproducibility of SWE proved to be moderate to substantial • The most reproducible SWE features between observers were SWE image homogeneity and maximum elasticity.

  6. Feasibility and observer reproducibility of speckle tracking echocardiography in congenital heart disease patients.

    PubMed

    Mokhles, Palwasha; van den Bosch, Annemien E; Vletter-McGhie, Jackie S; Van Domburg, Ron T; Ruys, Titia P E; Kauer, Floris; Geleijnse, Marcel L; Roos-Hesselink, Jolien W

    2013-09-01

    The twisting motion of the heart has an important role in the function of the left ventricle. Speckle tracking echocardiography is able to quantify left ventricular (LV) rotation and twist. So far this new technique has not been used in congenital heart disease patients. The aim of our study was to investigate the feasibility and the intra- and inter-observer reproducibility of LV rotation parameters in adult patients with congenital heart disease. The study population consisted of 66 consecutive patients seen in the outpatient clinic (67% male, mean age 31 ± 7.7 years, NYHA class 1 ± 0.3) with a variety of congenital heart disease. First, feasibility was assessed in all patients. Intra- and inter-observer reproducibility was assessed for the patients in which speckle tracking echocardiography was feasible. Adequate image quality, for performing speckle echocardiography, was found in 80% of patients. The bias for the intra-observer reproducibility of the LV twist was 0.0°, with 95% limits of agreement of -2.5° and 2.5° and for interobserver reproducibility the bias was 0.0°, with 95% limits of agreement of -3.0° and 3.0°. Intra- and inter-observer measurements showed a strong correlation (0.86 and 0.79, respectively). Also a good repeatability was seen. The mean time to complete full analysis per subject for the first and second measurement was 9 and 5 minutes, respectively. Speckle tracking echocardiography is feasible in 80% of adult patients with congenital heart disease and shows excellent intra- and inter-observer reproducibility. © 2013, Wiley Periodicals, Inc.

  7. Three-dimensional Frankfort horizontal plane for 3D cephalometry: a comparative assessment of conventional versus novel landmarks and horizontal planes.

    PubMed

    Pittayapat, Pisha; Jacobs, Reinhilde; Bornstein, Michael M; Odri, Guillaume A; Lambrichts, Ivo; Willems, Guy; Politis, Constantinus; Olszewski, Raphael

    2018-05-25

    To assess the reproducibility of landmarks in three dimensions that determine the Frankfort horizontal plane (FH) as well as two new landmarks, and to evaluate the angular differences of newly introduced planes to the FH. Three-dimensional (3D) surface models were created from CBCT scans of 26 dry human skulls. Porion (Po), orbitale (Or), internal acoustic foramen (IAF), and zygomatico-maxillary suture (ZyMS) were indicated in the software by three observers twice with a 4-week interval. Angles between two FHs (FH 1: Or-R, Or-L, mid-Po; FH 2: Po-R, Po-L, mid-Or) and between FHs and new planes (Plane 1-6) were measured. Coordinates were exported to a spreadsheet. A statistical analysis was performed to define the landmark reproducibility and 3D angles. Intra- and inter-observer landmark reproducibility showed mean difference more than 1 mm for x-coordinates of all landmarks except IAF. IAF showed significantly better reproducibility than other landmarks (P < 0.0018). The mean angular difference between FH 1 and FH 2 was 0.7 degrees. Plane 3, connecting Or-R, Or-L and mid-IAF, and Plane 4, connecting Po-R, Po-L and mid-ZyMS, both showed an angular difference of less than 1 degree when compared to FHs. This study revealed poor reproducibility of the traditional FH landmarks on the x-axis and good reproducibility of a new landmark tested to replace Po, the IAF. Yet, Or showed superior results compared to ZyMS. The potential of using new horizontal planes was demonstrated. Future studies should focus on identification of a valid alternative for Or and ZyMS and on clinical implementation of the findings.

  8. Reliability of basal plasma vasopressin concentrations in healthy male adults.

    PubMed

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Djupesland, Per G; Andreassen, Ole A

    2017-10-01

    The neuropeptides oxytocin (OT) and arginine vasopressin (AVP) play important and interrelated roles in modulating mammalian social behaviour. While the OT system has received considerable research attention for its potential to treat psychiatric symptoms, comparatively little is known about the role of the AVP system in human social behaviour. To better understand the intraindividual stability of basal AVP, the present study assessed the reproducibility of basal plasma AVP concentrations. Basal plasma AVP was assessed at four sampling points separated by 8 days, on average, in 16 healthy adult males. Only one out of six comparisons revealed strong evidence for reproducibility of basal AVP concentrations (visit 2 vs. visit 4: r=0.8, p0.1). The concordance correlation coefficient [0.15, 95% CI (-0.55, 0.73)] also revealed poor overall reproducibility. Poor reliability of basal AVP concentrations suggests future work covarying AVP with trait markers should proceed with careful consideration of intraindividual fluctuations.

  9. Imaging of striatal dopamine transporters in rat brain with single pinhole SPECT and co-aligned MRI is highly reproducible.

    PubMed

    Booij, Jan; de Bruin, Kora; de Win, Maartje M L; Lavini, Cristina; den Heeten, Gerard J; Habraken, Jan B A

    2003-08-01

    A recently developed pinhole high-resolution SPECT system was used to measure striatal to non-specific binding ratios in rats (n = 9), after injection of the dopamine transporter ligand (123)I-FP-CIT, and to assess its test/retest reproducibility. For co-alignment purposes, the rat brain was imaged on a 1.5 Tesla clinical MRI scanner using a specially developed surface coil. The SPECT images showed clear striatal uptake. On the MR images, cerebral and extra-cerebral structures could be easily delineated. The mean striatal to non-specific [(123)I]FP-CIT binding ratios of the test/retest studies were 1.7 +/- 0.2 and 1.6 +/- 0.2, respectively. The test/retest variability was approximately 9%. We conclude that the assessment of striatal [(123)I]FP-CIT binding ratios in rats is highly reproducible.

  10. Reproducibility of African giant pouched rats detecting Mycobacterium tuberculosis.

    PubMed

    Ellis, Haylee; Mulder, Christiaan; Valverde, Emilio; Poling, Alan; Edwards, Timothy

    2017-04-24

    African pouched rats sniffing sputum samples provided by local clinics have significantly increased tuberculosis case findings in Tanzania and Mozambique. The objective of this study was to determine the reproducibility of rat results. Over an 18-month period 11,869 samples were examined by the rats. Intra-rater reliability was assessed through Yule's Q. Inter-rater reliability was assessed with Krippendorff's alpha. Intra-rater reliability was high, with a mean Yule's Q of 0.9. Inter-rater agreement was fair, with Krippendorf's alpha ranging from 0.15 to 0.45. Both Intra- and Inter-rater reliability was independent of the sex of the animals, but they were positively correlated with age. Both intra- and inter-rater agreement was lowest for samples designated as smear-negative by the clinics. Overall, the reproducibility of tuberculosis detection rat results was fair and diagnostic results were therefore independent of the rats used.

  11. Reproducibility of straylight measurement by C-Quant for assessment of retinal straylight using the compensation comparison method.

    PubMed

    Guber, Ivo; Bachmann, Lucas M; Guber, Josef; Bochmann, Frank; Lange, Alex P; Thiel, Michael A

    2011-09-01

    Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.

  12. Echocardiographic agreement in the diagnostic evaluation for infective endocarditis.

    PubMed

    Lauridsen, Trine Kiilerich; Selton-Suty, Christine; Tong, Steven; Afonso, Luis; Cecchi, Enrico; Park, Lawrence; Yow, Eric; Barnhart, Huiman X; Paré, Carlos; Samad, Zainab; Levine, Donald; Peterson, Gail; Stancoven, Amy Butler; Johansson, Magnus Carl; Dickerman, Stuart; Tamin, Syahidah; Habib, Gilbert; Douglas, Pamela S; Bruun, Niels Eske; Crowley, Anna Lisa

    2016-07-01

    Echocardiography is essential for the diagnosis and management of infective endocarditis (IE). However, the reproducibility for the echocardiographic assessment of variables relevant to IE is unknown. Objectives of this study were: (1) To define the reproducibility for IE echocardiographic variables and (2) to describe a methodology for assessing quality in an observational cohort containing site-interpreted data. IE reproducibility was assessed on a subset of echocardiograms from subjects enrolled in the International Collaboration on Endocarditis registry. Specific echocardiographic case report forms were used. Intra-observer agreement was assessed from six site readers on ten randomly selected echocardiograms. Inter-observer agreement between sites and an echocardiography core laboratory was assessed on a separate random sample of 110 echocardiograms. Agreement was determined using intraclass correlation (ICC), coverage probability (CP), and limits of agreement for continuous variables and kappa statistics (κweighted) and CP for categorical variables. Intra-observer agreement for LVEF was excellent [ICC = 0.93 ± 0.1 and all pairwise differences for LVEF (CP) were within 10 %]. For IE categorical echocardiographic variables, intra-observer agreement was best for aortic abscess (κweighted = 1.0, CP = 1.0 for all readers). Highest inter-observer agreement for IE categorical echocardiographic variables was obtained for vegetation location (κweighted = 0.95; 95 % CI 0.92-0.99) and lowest agreement was found for vegetation mobility (κweighted = 0.69; 95 % CI 0.62-0.86). Moderate to excellent intra- and inter-observer agreement is observed for echocardiographic variables in the diagnostic assessment of IE. A pragmatic approach for determining echocardiographic data reproducibility in a large, multicentre, site interpreted observational cohort is feasible.

  13. Feasibility and reproducibility of feature-tracking-based strain and strain rate measures of the left ventricle in different diseases and genders.

    PubMed

    Maceira, Alicia M; Tuset-Sanchis, Luis; López-Garrido, Miguel; San Andres, Marta; López-Lereu, M Pilar; Monmeneu, Jose V; García-González, M Pilar; Higueras, Laura

    2018-05-01

    The measurement of myocardial deformation by strain analysis is an evolving tool to quantify regional and global myocardial function. To assess the feasibility and reproducibility of myocardial strain/strain rate measurements with magnetic resonance feature tracking (MR-FT) in healthy subjects and in patient groups. Prospective study. Sixty patients (20 hypertensives with left ventricular (LV) hypertrophy (H); 20 nonischemic dilated cardiomyopathy (D); 20 ischemic heart disease (I); as well as 20 controls (C) were included, 10 men and 10 women in each group. A 1.5T MR protocol including steady-state free precession (SSFP) cine sequences in the standard views and late enhancement sequences. LV volumes, mass, global and regional radial, circumferential, and longitudinal strain/strain rate were measured using CVI42 software. The analysis time was recorded. Intraobserver and interobserver agreement and intraclass correlation coefficients (ICC) were obtained for reproducibility assessment as well as differences according to gender and group of pertinence. Strain/strain rate analysis could be achieved in all subjects. The average analysis time was 14 ± 3 minutes. The average intraobserver ICC was excellent (ICC >0.90) for strain and good (ICC >0.75) for strain rate. Reproducibility of strain measurements was good to excellent (ICC >0.75) for all groups of subjects and both genders. Reproducibility of strain measurements was good for basal segments (ICC >0.75) and excellent for middle and apical segments (ICC >0.90). Reproducibility of strain rate measurements was moderate for basal segments (ICC >0.50) and good for middle and apical segments. MR-FT for strain/strain rate analysis is a feasible and highly reproducible technique. CVI42 FT analysis was equally feasible and reproducible in various pathologies and between genders. Better reproducibility was seen globally for middle and apical segments, which needs further clarification. 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018;47:1415-1425. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Diffusion Properties and 3D Architecture of Human Lower Leg Muscles Assessed with Ultra-High-Field-Strength Diffusion-Tensor MR Imaging and Tractography: Reproducibility and Sensitivity to Sex Difference and Intramuscular Variability.

    PubMed

    Fouré, Alexandre; Ogier, Augustin C; Le Troter, Arnaud; Vilmen, Christophe; Feiweier, Thorsten; Guye, Maxime; Gondin, Julien; Besson, Pierre; Bendahan, David

    2018-05-01

    Purpose To demonstrate the reproducibility of the diffusion properties and three-dimensional structural organization measurements of the lower leg muscles by using diffusion-tensor imaging (DTI) assessed with ultra-high-field-strength (7.0-T) magnetic resonance (MR) imaging and tractography of skeletal muscle fibers. On the basis of robust statistical mapping analyses, this study also aimed at determining the sensitivity of the measurements to sex difference and intramuscular variability. Materials and Methods All examinations were performed with ethical review board approval; written informed consent was obtained from all volunteers. Reproducibility of diffusion tensor indexes assessment including eigenvalues, mean diffusivity, and fractional anisotropy (FA) as well as muscle volume and architecture (ie, fiber length and pennation angle) were characterized in lower leg muscles (n = 8). Intramuscular variability and sex differences were characterized in young healthy men and women (n = 10 in each group). Student t test, statistical parametric mapping, correlation coefficients (Spearman rho and Pearson product-moment) and coefficient of variation (CV) were used for statistical data analysis. Results High reproducibility of measurements (mean CV ± standard deviation, 4.6% ± 3.8) was determined in diffusion properties and architectural parameters. Significant sex differences were detected in FA (4.2% in women for the entire lower leg; P = .001) and muscle volume (21.7% in men for the entire lower leg; P = .008), whereas architecture parameters were almost identical across sex. Additional differences were found independently of sex in diffusion properties and architecture along several muscles of the lower leg. Conclusion The high-spatial-resolution DTI assessed with 7.0-T MR imaging allows a reproducible assessment of structural organization of superficial and deep muscles, giving indirect information on muscle function. © RSNA, 2018 Online supplemental material is available for this article.

  15. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  16. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  17. Recommendations for assessing the risk of bias in systematic reviews of health-care interventions.

    PubMed

    Viswanathan, Meera; Patnode, Carrie D; Berkman, Nancy D; Bass, Eric B; Chang, Stephanie; Hartling, Lisa; Murad, M Hassan; Treadwell, Jonathan R; Kane, Robert L

    2018-05-01

    Risk-of-bias assessment is a central component of systematic reviews, but little conclusive empirical evidence exists on the validity of such assessments. In the context of such uncertainty, we present pragmatic recommendations that promote transparency and reproducibility in processes, address methodological advances in the risk-of-bias assessment, and can be applied consistently across review topics. Epidemiological study design principles; available empirical evidence, risk-of-bias tools, and guidance; and workgroup consensus. We developed recommendations for assessing the risk of bias of studies of health-care interventions specific to framing the focus and scope of risk-of-bias assessment; selecting the risk-of-bias categories; choosing assessment instruments; and conducting, analyzing, and presenting results of risk-of-bias assessments. Key recommendations include transparency and reproducibility of judgments, separating risk of bias from other constructs such as applicability and precision, and evaluating the risk of bias per outcome. We recommend against certain past practices, such as focusing on reporting quality, relying solely on study design or numerical quality scores, and automatically downgrading for industry sponsorship. Risk-of-bias assessment remains a challenging but essential step in systematic reviews. We presented standards to promote transparency of judgments. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Identification and reproducibility of dietary patterns in a Danish cohort: the Inter99 study.

    PubMed

    Lau, Cathrine; Glümer, Charlotte; Toft, Ulla; Tetens, Inge; Carstensen, Bendix; Jørgensen, Torben; Borch-Johnsen, Knut

    2008-05-01

    We aimed to identify dietary patterns in a Danish adult population and assess the reproducibility of the dietary patterns identified. Baseline data of 3,372 women and 3,191 men (30-60 years old) from the population-based survey Inter99 was used. Food intake, assessed by a FFQ, was aggregated into thirty-four separate food groups. Dietary patterns were identified by principal component analysis. Confirmatory factor analysis and Bland Altman plots were used to assess the reproducibility of the dietary patterns identified. The Bland Altman plots were used as an alternative and new method. Two factors were retained for both women and men, which accounted for 15.1-17.4 % of the total variation. The 'Traditional' pattern was characterised by high loadings ( > or = 0.40) on paté or high-fat meat for sandwiches, mayonnaise salads, red meat, potatoes, butter and lard, low-fat fish, low-fat meat for sandwiches, and sauces. The 'Modern' pattern was characterised by high loadings on vegetables, fruit, mixed vegetable dishes, vegetable oil and vinegar dressing, poultry, and pasta, rice and wheat kernels. Small differences were observed between patterns identified for women and men. The root mean square error approximation from the confirmatory factor analysis was 0.08. The variation observed from the Bland Altman plots of factors from explorative v. confirmative analyses and explorative analyses from two sub-samples was between 18.8 and 47.7 %. Pearson's correlation was >0.89 (P < 0.0001). The reproducibility was better for women than for men. We conclude that the 'Traditional' and 'Modern' dietary patterns identified were reproducible.

  19. Reproducibility of the Online Food4Me Food-Frequency Questionnaire for Estimating Dietary Intakes across Europe.

    PubMed

    Marshall, Steven J; Livingstone, Katherine M; Celis-Morales, Carlos; Forster, Hannah; Fallaize, Rosalind; O'Donovan, Clare B; Woolhead, Clara; Marsaux, Cyril Fm; Macready, Anna L; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Kolossa, Silvia; Tsirigoti, Lydia; Lambrinou, Christina P; Moschonis, George; Godlewska, Magdalena; Surwiłło, Agnieszka; Drevon, Christian A; Manios, Yannis; Traczyk, Iwona; Martínez, J Alfredo; Saris, Wim H; Daniel, Hannelore; Gibney, Eileen R; Brennan, Lorraine; Walsh, Marianne C; Lovegrove, Julie A; Gibney, Mike; Mathers, John C

    2016-05-01

    Accurate dietary assessment is key to understanding nutrition-related outcomes and is essential for estimating dietary change in nutrition-based interventions. The objective of this study was to assess the pan-European reproducibility of the Food4Me food-frequency questionnaire (FFQ) in assessing the habitual diet of adults. Participants from the Food4Me study, a 6-mo, Internet-based, randomized controlled trial of personalized nutrition conducted in the United Kingdom, Ireland, Spain, Netherlands, Germany, Greece, and Poland, were included. Screening and baseline data (both collected before commencement of the intervention) were used in the present analyses, and participants were included only if they completed FFQs at screening and at baseline within a 1-mo timeframe before the commencement of the intervention. Sociodemographic (e.g., sex and country) and lifestyle [e.g., body mass index (BMI, in kg/m(2)) and physical activity] characteristics were collected. Linear regression, correlation coefficients, concordance (percentage) in quartile classification, and Bland-Altman plots for daily intakes were used to assess reproducibility. In total, 567 participants (59% female), with a mean ± SD age of 38.7 ± 13.4 y and BMI of 25.4 ± 4.8, completed both FFQs within 1 mo (mean ± SD: 19.2 ± 6.2 d). Exact plus adjacent classification of total energy intake in participants was highest in Ireland (94%) and lowest in Poland (81%). Spearman correlation coefficients (ρ) in total energy intake between FFQs ranged from 0.50 for obese participants to 0.68 and 0.60 in normal-weight and overweight participants, respectively. Bland-Altman plots showed a mean difference between FFQs of 210 kcal/d, with the agreement deteriorating as energy intakes increased. There was little variation in reproducibility of total energy intakes between sex and age groups. The online Food4Me FFQ was shown to be reproducible across 7 European countries when administered within a 1-mo period to a large number of participants. The results support the utility of the online Food4Me FFQ as a reproducible tool across multiple European populations. This trial was registered at clinicaltrials.gov as NCT01530139. © 2016 American Society for Nutrition.

  20. Barostat testing of rectal sensation and compliance in humans: comparison of results across two centres and overall reproducibility.

    PubMed

    Cremonini, F; Houghton, L A; Camilleri, M; Ferber, I; Fell, C; Cox, V; Castillo, E J; Alpers, D H; Dewit, O E; Gray, E; Lea, R; Zinsmeister, A R; Whorwell, P J

    2005-12-01

    We assessed reproducibility of measurements of rectal compliance and sensation in health in studies conducted at two centres. We estimated samples size necessary to show clinically meaningful changes in future studies. We performed rectal barostat tests three times (day 1, day 1 after 4 h and 14-17 days later) in 34 healthy participants. We measured compliance and pressure thresholds for first sensation, urgency, discomfort and pain using ascending method of limits and symptom ratings for gas, urgency, discomfort and pain during four phasic distensions (12, 24, 36 and 48 mmHg) in random order. Results obtained at the two centres differed minimally. Reproducibility of sensory end points varies with type of sensation, pressure level and method of distension. Pressure threshold for pain and sensory ratings for non-painful sensations at 36 and 48 mmHg distension were most reproducible in the two centres. Sample size calculations suggested that crossover design is preferable in therapeutic trials: for each dose of medication tested, a sample of 21 should be sufficient to demonstrate 30% changes in all sensory thresholds and almost all sensory ratings. We conclude that reproducibility varies with sensation type, pressure level and distension method, but in a two-centre study, differences in observed results of sensation are minimal and pressure threshold for pain and sensory ratings at 36-48 mmHg of distension are reproducible.

  1. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    PubMed

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  2. [Reproducibility, internal consistency, and construct validity of KIDSCREEN-27 in Brazilian adolescents].

    PubMed

    Farias, José Cazuza de; Loch, Mathias Roberto; Lima, Antônio José de; Sales, Joana Marcela; Ferreira, Flávia Emília Leite de Lima

    2017-09-28

    : The objective of this two-part study was to estimate the reproducibility, internal consistency, and construct validity of KIDSCREEN-27, a questionnaire to measure health-related quality of life, in Brazilian adolescents. One study component estimated reproducibility (176 adolescents, 59.7% females, 64.7% 10 to 12 years of age), and another estimated internal consistency and validity (1,321 adolescents, 53.7% females, 56.9% 10 to 12 years of age). The studies were conducted with adolescents of both sexes in public schools in the municipality of João Pessoa, Paraíba State, Brazil. KIDSCREEN-27 consists of 27 items distributed across five domains (physical well-being, 5 items; psychological well-being, 7 items; parents and social support, 7 items; autonomy and relationship with parents, 4 items; school environment, 4 items). Reproducibility was estimated by intra-class correlation coefficient (ICC). Confirmatory factor analysis was used to assess construct validity, and composite reliability index (CRI) was used to verify the questionnaire's internal consistency. ICCs were greater than or equal to 0.70 (0.70 to 0.96). Factor loads were greater than 0.40, except for five items (0.28 to 0.39). The model's goodness-of-fit indices were adequate (χ2/df = 2.79; RMR = 0.035; RMSEA = 0.037; GFI = 0.951; AGFI = 0.941; CFI = 0.908; TLI = 0.901). CRI varied from 0.65 to 0.70 in the domains and was 0.90 for the questionnaire. KIDSCREEN-27 reached satisfactory levels of reproducibility, internal consistency, and construct validity and can be used to assess health-related quality of life in Brazilian adolescents 10 to 15 years of age.

  3. CHLORINE DISINFECTION STUDIES OF ENCEPHALITOZOON (SEPTATA) INTESTINALIS

    EPA Science Inventory

    A reproducible standardized assay was designed to determine two infective doses for E.intestinalis, the TCID50 and the MID. These doses can be used to assess the potential effectiveness of chlorine disinfection and can also be used to assess other disinfection parameters and ant...

  4. Repeatability and Reproducibility of Decisions by Latent Fingerprint Examiners

    PubMed Central

    Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia

    2012-01-01

    The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner) results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive) was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as “difficult” than for “easy” or “moderate” comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4); 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization). Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases. PMID:22427888

  5. Development and evaluation of an automatic method for the study of platelet osmotic response.

    PubMed

    Gigout, T; Blondel, W; Didelon, J; Latger, V; Dumas, D; Schooneman, F; Stoltz, J F

    1999-01-01

    Study of the osmotic resistance to hypotonic medium of platelets has often been suggested as a global test to assess the viability of these cells in transfusion or to study modification during haematological pathologies. A number of authors have analysed the behaviour of platelets in hypotonic media by a variety of methods (cell count, determinations of substances released, morphology, etc.), but most studies are currently based on the so-called "Hypotonic Shock Response" test (HSR). In this study, the authors describe a new automated and reproducible apparatus, called fragilimeter, using slow dialysis to assess platelet osmotic resistance. The variations in light transmission through a platelet suspension according to ionic strength are linked to the change in cellular volume and lysis and characterise the osmotic behaviour of the cells. The results revealed the good reproducibility and sensibility of the technique. This apparatus allows also the realisation of the "HSR" test.

  6. Automated, computer-guided PASI measurements by digital image analysis versus conventional physicians' PASI calculations: study protocol for a comparative, single-centre, observational study.

    PubMed

    Fink, Christine; Uhlmann, Lorenz; Klose, Christina; Haenssle, Holger A

    2018-05-17

    Reliable and accurate assessment of severity in psoriasis is very important in order to meet indication criteria for initiation of systemic treatment or to evaluate treatment efficacy. The most acknowledged tool for measuring the extent of psoriatic skin changes is the Psoriasis Area and Severity Index (PASI). However, the calculation of PASI can be tedious and subjective and high intraobserver and interobserver variability is an important concern. Therefore, there is a great need for a standardised and objective method that guarantees a reproducible PASI calculation. Within this study we will investigate the precision and reproducibility of automated, computer-guided PASI measurements in comparison to trained physicians to address these limitations. Non-interventional analyses of PASI calculations by either physicians in a prospective versus retrospective setting or an automated computer-guided algorithm in 120 patients with plaque psoriasis. All retrospective PASI calculations by physicians or by the computer algorithm are based on total body digital images. The primary objective of this study is comparison of automated computer-guided PASI measurements by means of digital image analysis versus conventional, prospective or retrospective physicians' PASI assessments. Secondary endpoints include (1) the assessment of physicians' interobserver variance in PASI calculations, (2) the assessment of physicians' intraobserver variance in PASI assessments of the same patients' images after a time interval of at least 4 weeks, (3) the assessment of the deviation between physicians' prospective versus retrospective PASI calculations, and (4) the reproducibility of automated computer-guided PASI measurements by assessment of two sets of total body digital images of the same patients taken at one time point. Ethical approval was provided by the Ethics Committee of the Medical Faculty of the University of Heidelberg (ethics approval number S-379/2016). DRKS00011818; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study

    PubMed Central

    van de Water, Tanja; Faber, Irene; Elferink-Gemser, Marije

    2017-01-01

    Abstract Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p < 0.05). Elite players did not outscore non-elite players on domain-general reaction time nor on both components of inhibitory control (p > 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p < 0.01) and non-elite (p = 0.70, p < 0.05) players. No relationship was found between the national ranking and badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players’ performance. PMID:28210347

  8. Assessing Cognitive Performance in Badminton Players: A Reproducibility and Validity Study.

    PubMed

    van de Water, Tanja; Huijgen, Barbara; Faber, Irene; Elferink-Gemser, Marije

    2017-01-01

    Fast reaction and good inhibitory control are associated with elite sports performance. To evaluate the reproducibility and validity of a newly developed Badminton Reaction Inhibition Test (BRIT), fifteen elite (25 ± 4 years) and nine non-elite (24 ± 4 years) Dutch male badminton players participated in the study. The BRIT measured four components: domain-general reaction time, badminton-specific reaction time, domain-general inhibitory control and badminton-specific inhibitory control. Five participants were retested within three weeks on the badminton-specific components. Reproducibility was acceptable for badminton-specific reaction time (ICC = 0.626, CV = 6%) and for badminton-specific inhibitory control (ICC = 0.317, CV = 13%). Good construct validity was shown for badminton-specific reaction time discriminating between elite and non-elite players (F = 6.650, p < 0.05). Elite players did not outscore non-elite players on domain-general reaction time nor on both components of inhibitory control (p > 0.05). Concurrent validity for domain-general reaction time was good, as it was associated with a national ranking for elite (p = 0.70, p < 0.01) and non-elite (p = 0.70, p < 0.05) players. No relationship was found between the national ranking and badminton-specific reaction time, nor both components of inhibitory control (p > 0.05). In conclusion, reproducibility and validity of inhibitory control assessment was not confirmed, however, the BRIT appears a reproducible and valid measure of reaction time in badminton players. Reaction time measured with the BRIT may provide input for training programs aiming to improve badminton players' performance.

  9. Three-dimensional ultrasound molecular imaging of angiogenesis in colon cancer using a clinical matrix array ultrasound transducer.

    PubMed

    Wang, Huaijun; Kaneko, Osamu F; Tian, Lu; Hristov, Dimitre; Willmann, Jürgen K

    2015-05-01

    We sought to assess the feasibility and reproducibility of 3-dimensional ultrasound molecular imaging (USMI) of vascular endothelial growth factor receptor 2 (VEGFR2) expression in tumor angiogenesis using a clinical matrix array transducer and a clinical grade VEGFR2-targeted contrast agent in a murine model of human colon cancer. Animal studies were approved by the Institutional Administrative Panel on Laboratory Animal Care. Mice with human colon cancer xenografts (n = 33) were imaged with a clinical ultrasound system and transducer (Philips iU22; X6-1) after intravenous injection of either clinical grade VEGFR2-targeted microbubbles or nontargeted control microbubbles. Nineteen mice were scanned twice to assess imaging reproducibility. Fourteen mice were scanned both before and 24 hours after treatment with either bevacizumab (n = 7) or saline only (n = 7). Three-dimensional USMI data sets were retrospectively reconstructed into multiple consecutive 1-mm-thick USMI data sets to simulate 2-dimensional imaging. Vascular VEGFR2 expression was assessed ex vivo using immunofluorescence. Three-dimensional USMI was highly reproducible using both VEGFR2-targeted microbubbles and nontargeted control microbubbles (intraclass correlation coefficient, 0.83). The VEGFR2-targeted USMI signal significantly (P = 0.02) decreased by 57% after antiangiogenic treatment compared with the control group, which correlated well with ex vivo VEGFR2 expression on immunofluorescence (ρ = 0.93, P = 0.003). If only central 1-mm tumor planes were analyzed to assess antiangiogenic treatment response, the USMI signal change was significantly (P = 0.006) overestimated by an average of 27% (range, 2%-73%) compared with 3-dimensional USMI. Three-dimensional USMI is feasible and highly reproducible and allows accurate assessment and monitoring of VEGFR2 expression in tumor angiogenesis in a murine model of human colon cancer.

  10. Reproducibility of radiomics for deciphering tumor phenotype with imaging

    NASA Astrophysics Data System (ADS)

    Zhao, Binsheng; Tan, Yongqiang; Tsai, Wei-Yann; Qi, Jing; Xie, Chuanmiao; Lu, Lin; Schwartz, Lawrence H.

    2016-03-01

    Radiomics (radiogenomics) characterizes tumor phenotypes based on quantitative image features derived from routine radiologic imaging to improve cancer diagnosis, prognosis, prediction and response to therapy. Although radiomic features must be reproducible to qualify as biomarkers for clinical care, little is known about how routine imaging acquisition techniques/parameters affect reproducibility. To begin to fill this knowledge gap, we assessed the reproducibility of a comprehensive, commonly-used set of radiomic features using a unique, same-day repeat computed tomography data set from lung cancer patients. Each scan was reconstructed at 6 imaging settings, varying slice thicknesses (1.25 mm, 2.5 mm and 5 mm) and reconstruction algorithms (sharp, smooth). Reproducibility was assessed using the repeat scans reconstructed at identical imaging setting (6 settings in total). In separate analyses, we explored differences in radiomic features due to different imaging parameters by assessing the agreement of these radiomic features extracted from the repeat scans reconstructed at the same slice thickness but different algorithms (3 settings in total). Our data suggest that radiomic features are reproducible over a wide range of imaging settings. However, smooth and sharp reconstruction algorithms should not be used interchangeably. These findings will raise awareness of the importance of properly setting imaging acquisition parameters in radiomics/radiogenomics research.

  11. Validation, reliability, and specificity of CliniCom™ Psychiatric Assessment Software.

    PubMed

    Handal, Nelson; LePage, James; Dayley, Philip; Baldwin, Barbara; Roeser, Amellia; Kay, Joni; Theobald, Heather Ann; Nellamattathil, Michael; Drotar, Scott; Weir, Connor; Tindell, Neil; Tice, Kevin

    2018-07-01

    The purpose of this study was to determine the specificity and reproducibility of CliniCom™ Psychiatric Assessment Software to appropriately diagnose five prevalent mental health disorders. This online assessment tool incorporates proprietary algorithms for its propensity assessment. Unlike other questionnaires, which require a survey per specific mental disorder, CliniCom can simultaneously assess multiple mental disorders for an individual. CliniCom was concordant with other commonly used assessment tools in diagnosing five prevalent disorders including: Attention Deficit and Hyperactivity Disorder, Generalized Anxiety Disorder, Major Depressive Disorder, Obsessive Compulsive Disorder, and Social Phobia. The online tool was overall 78% concordant in diagnosing the same disorder during a test-retest analysis. When subjects exhibited two, three, or four disorders, the tool was less consistent in diagnosing the same set of disorders during the test-retest analysis (53% concordant). However, if evaluated as individual disorders within subjects, the more persistent disorders had a higher rate of concordance: MDD (83.3%), ADHD (81.0%), and OCD (68.4%). This study proposes CliniCom as an online assessment tool that demonstrates specificity in identifying specific psychiatric conditions and shows reproducibility over multiple administrations. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Reproducibility and validity of the Dutch translation of the de Morton Mobility Index (DEMMI) used by physiotherapists in older patients with knee or hip osteoarthritis.

    PubMed

    Jans, Marielle P; Slootweg, Vera C; Boot, Cecile R; de Morton, Natalie A; van der Sluis, Geert; van Meeteren, Nico L

    2011-11-01

    To examine the reproducibility, construct validity, and unidimensionality of the Dutch translation of the de Morton Mobility Index (DEMMI), a performance-based measure of mobility for older patients. Cross-sectional study. Rehabilitation center (reproducibility study) and hospital (validity study). Patients (N=28; age >65y) after orthopedic surgery (reproducibility study) and patients (N=219; age >65y) waiting for total hip or total knee arthroplasty (validity study). Not applicable. Not applicable. The intraclass correlation coefficient for interrater reliability was high (.85; 95% confidence interval, 71-.93), and minimal detectable change with 90% confidence was 7 on the 100-point DEMMI scale. Rasch analysis identified that the Dutch translation of the DEMMI is a unidimensional measure of mobility in this population. DEMMI scores showed high correlations with scores on other performance-based measures of mobility (Timed Up and Go test, Spearman r=-.73; Chair Rise Time, r=-.69; walking test, r=.74). A lower correlation of .44 was identified with the self-report measure Western Ontario and McMaster Universities Osteoarthritis Index. The Dutch translation of the DEMMI is a reproducible and valid performance-based measure for assessing mobility in older patients with knee or hip osteoarthritis. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

    PubMed

    Chen, Kevin T; Izquierdo-Garcia, David; Poynton, Clare B; Chonde, Daniel B; Catana, Ciprian

    2017-03-01

    To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.

  14. Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level in patients after total knee arthroplasty.

    PubMed

    Bolszak, Sylvain; Casartelli, Nicola C; Impellizzeri, Franco M; Maffiuletti, Nicola A

    2014-02-20

    The need for valid and reproducible questionnaires to routinely assess the physical activity level of patients after total knee arthroplasty (TKA) is of particular concern in clinical settings. Aims of this study were to evaluate the validity and reproducibility of the physical activity scale for the elderly (PASE) questionnaire in TKA patients, with a particular view on gender differences. A total of 50 elderly patients (25 women and 25 men aged 70 ± 6 years) following primary unilateral TKA were recruited. The reproducibility was evaluated by administering the PASE questionnaire during two occasions separated by 7 days. The construct (criterion) validity was investigated by comparing the physical activity level reported by patients in the PASE questionnaire to that measured by accelerometry. Reproducibility was evaluated using intraclass correlation coefficients (ICC3,1) for reliability and standard error of measurement (SEM) and smallest detectable change (SDC) for agreement, while validity was investigated with Pearson correlation coefficients. Reliability of the PASE total score was acceptable for men (ICC = 0.77) but not for women (ICC = 0.58). Its agreement was low for both men and women, as witnessed by high SEM (32% and 35%, respectively) and SDC (89% and 97%, respectively). Construct validity of the PASE total score was low in both men (r = 0.45) and women (r = 0.06). The PASE questionnaire has several validity and reproducibility shortcomings, therefore its use is not recommended for the assessment of physical activity level in patients after TKA, particularly in women.

  15. Commentary on the Integration of Model Sharing and Reproducibility Analysis to Scholarly Publishing Workflow in Computational Biomechanics

    PubMed Central

    Erdemir, Ahmet; Guess, Trent M.; Halloran, Jason P.; Modenese, Luca; Reinbolt, Jeffrey A.; Thelen, Darryl G.; Umberger, Brian R.

    2016-01-01

    Objective The overall goal of this document is to demonstrate that dissemination of models and analyses for assessing the reproducibility of simulation results can be incorporated in the scientific review process in biomechanics. Methods As part of a special issue on model sharing and reproducibility in IEEE Transactions on Biomedical Engineering, two manuscripts on computational biomechanics were submitted: A. Rajagopal et al., IEEE Trans. Biomed. Eng., 2016 and A. Schmitz and D. Piovesan, IEEE Trans. Biomed. Eng., 2016. Models used in these studies were shared with the scientific reviewers and the public. In addition to the standard review of the manuscripts, the reviewers downloaded the models and performed simulations that reproduced results reported in the studies. Results There was general agreement between simulation results of the authors and those of the reviewers. Discrepancies were resolved during the necessary revisions. The manuscripts and instructions for download and simulation were updated in response to the reviewers’ feedback; changes that may otherwise have been missed if explicit model sharing and simulation reproducibility analysis were not conducted in the review process. Increased burden on the authors and the reviewers, to facilitate model sharing and to repeat simulations, were noted. Conclusion When the authors of computational biomechanics studies provide access to models and data, the scientific reviewers can download and thoroughly explore the model, perform simulations, and evaluate simulation reproducibility beyond the traditional manuscript-only review process. Significance Model sharing and reproducibility analysis in scholarly publishing will result in a more rigorous review process, which will enhance the quality of modeling and simulation studies and inform future users of computational models. PMID:28072567

  16. Use of Laser Speckle Contrast Imaging to Assess Digital Microvascular Function in Primary Raynaud Phenomenon and Systemic Sclerosis: A Comparison Using the Raynaud Condition Score Diary.

    PubMed

    Pauling, John D; Shipley, Jacqueline A; Hart, Darren J; McGrogan, Anita; McHugh, Neil J

    2015-07-01

    Evaluate objective assessment of digital microvascular function using laser speckle contrast imaging (LSCI) in a cross-sectional study of patients with primary Raynaud phenomenon (RP) and systemic sclerosis (SSc), comparing LSCI with both infrared thermography (IRT) and subjective assessment using the Raynaud Condition Score (RCS) diary. Patients with SSc (n = 25) and primary RP (n = 18) underwent simultaneous assessment of digital perfusion using LSCI and IRT with a cold challenge on 2 occasions, 2 weeks apart. The RCS diary was completed between assessments. The relationship between objective and subjective assessments of RP was evaluated. Reproducibility of LSCI/IRT was assessed, along with differences between primary RP and SSc, and the effect of sex. There was moderate-to-good correlation between LSCI and IRT (Spearman rho 0.58-0.84, p < 0.01), but poor correlation between objective assessments and the RCS diary (p > 0.05 for all analyses). Reproducibility of IRT and LSCI was moderate at baseline (ICC 0.51-0.63) and immediately following cold challenge (ICC 0.56-0.86), but lower during reperfusion (ICC 0.3-0.7). Neither subjective nor objective assessments differentiated between primary RP and SSc. Men reported lower median daily frequency of RP attacks (0.82 vs 1.93, p = 0.03). Perfusion using LSCI/IRT was higher in men for the majority of assessments. Objective and subjective methods provide differing information on microvascular function in RP. There is good convergent validity of LSCI with IRT and acceptable reproducibility of both modalities. Neither subjective nor objective assessments could differentiate between primary RP and SSc. Influence of sex on subjective and objective assessment of RP warrants further evaluation.

  17. Molecular markers for urothelial bladder cancer prognosis: toward implementation in clinical practice.

    PubMed

    van Rhijn, Bas W G; Catto, James W; Goebell, Peter J; Knüchel, Ruth; Shariat, Shahrokh F; van der Poel, Henk G; Sanchez-Carbayo, Marta; Thalmann, George N; Schmitz-Dräger, Bernd J; Kiemeney, Lambertus A

    2014-10-01

    To summarize the current status of clinicopathological and molecular markers for the prediction of recurrence or progression or both in non-muscle-invasive and survival in muscle-invasive urothelial bladder cancer, to address the reproducibility of pathology and molecular markers, and to provide directions toward implementation of molecular markers in future clinical decision making. Immunohistochemistry, gene signatures, and FGFR3-based molecular grading were used as molecular examples focussing on prognostics and issues related to robustness of pathological and molecular assays. The role of molecular markers to predict recurrence is limited, as clinical variables are currently more important. The prediction of progression and survival using molecular markers holds considerable promise. Despite a plethora of prognostic (clinical and molecular) marker studies, reproducibility of pathology and molecular assays has been understudied, and lack of reproducibility is probably the main reason that individual prediction of disease outcome is currently not reliable. Molecular markers are promising to predict progression and survival, but not recurrence. However, none of these are used in the daily clinical routine because of reproducibility issues. Future studies should focus on reproducibility of marker assessment and consistency of study results by incorporating scoring systems to reduce heterogeneity of reporting. This may ultimately lead to incorporation of molecular markers in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Reproducibility of the School-Based Nutrition Monitoring Questionnaire among Fourth-Grade Students in Texas

    ERIC Educational Resources Information Center

    Penkilo, Monica; George, Goldy Chacko; Hoelscher, Deanna M.

    2008-01-01

    Objective: To assess reproducibility of a School-Based Nutrition Monitoring (SBNM) questionnaire for fourth-grade students. Design: Test-retest. Setting: Fourth-grade elementary school classrooms. Participants: Multiethnic fourth-grade students from 2 area school districts (N = 322). Main Outcome Measures: Reproducibility coefficients with time…

  19. Composting in small laboratory pilots: performance and reproducibility.

    PubMed

    Lashermes, G; Barriuso, E; Le Villio-Poitrenaud, M; Houot, S

    2012-02-01

    Small-scale reactors (<10 l) have been employed in composting research, but few attempts have assessed the performance of composting considering the transformations of organic matter. Moreover, composting at small scales is often performed by imposing a fixed temperature, thus creating artificial conditions, and the reproducibility of composting has rarely been reported. The objectives of this study are to design an innovative small-scale composting device safeguarding self-heating to drive the composting process and to assess the performance and reproducibility of composting in small-scale pilots. The experimental setup included six 4-l reactors used for composting a mixture of sewage sludge and green wastes. The performance of the process was assessed by monitoring the temperature, O(2) consumption and CO(2) emissions, and characterising the biochemical evolution of organic matter. A good reproducibility was found for the six replicates with coefficients of variation for all parameters generally lower than 19%. An intense self-heating ensured the existence of a spontaneous thermophilic phase in all reactors. The average loss of total organic matter (TOM) was 46% of the initial content. Compared to the initial mixture, the hot water soluble fraction decreased by 62%, the hemicellulose-like fraction by 68%, the cellulose-like fraction by 50% and the lignin-like fractions by 12% in the final compost. The TOM losses, compost stabilisation and evolution of the biochemical fractions were similar to observed in large reactors or on-site experiments, excluding the lignin degradation, which was less important than in full-scale systems. The reproducibility of the process and the quality of the final compost make it possible to propose the use of this experimental device for research requiring a mass reduction of the initial composted waste mixtures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Validity and reproducibility of a food frequency questionnaire for assessment of fruit and vegetable intake in Iranian adults*

    PubMed Central

    Mohammadifard, Noushin; Omidvar, Nasrin; Houshiarrad, Anahita; Neyestani, Tirang; Naderi, Gholam-Ali; Soleymani, Bahram

    2011-01-01

    BACKGROUND: This study's aim was to design and validate a semi-quantitative food frequency questionnaire (FFQ) for assessment of fruits and vegetables (FV) consumption in adults of Isfahan by comparing the FFQ with dietary reference method and blood plasma levels of beta-carotene, vitamin C, and retinol. METHODS: This validation study was performed on 123 healthy adults of Isfahan. FV intake was assessed using a 110-item FFQ. Data collection was performed during two different time periods to control for seasonal effects, fall/winter (cold season) and spring/summer (warm season). In each phase a FFQ and 1 day recall, and 2 days of food records as the dietary reference method were completed and plasma vitamin C, beta-carotene and retinol were measured. Data was analyzed by Pearson or Spearman and intraclass correlations. RESULTS: Serum Lipids, sex, age, body mass index (BMI) and educational level adjusted Pearson correlation coefficient of FV with plasma vitamin C, beta-carotene and retinol were 0.55, 0.47 and 0.28 in the cold season (p < 0.05) and 0.52, 0.45 and 0.35 in the warm season (p < 0.001), respectively. Energy and fat intake, sex, age, BMI and educational level adjusted Pearson correlation coefficient for FV with dietary reference method in the cold and warm seasons were 0.62 and 0.60, respectively (p < 0.001). Intraclass correlation for reproducibility of FFQ in FV was 0.65 (p<0.001). CONCLUSIONS: The designed FFQ had a good criterion validity and reproducibility for assessment of FV intake. Thus, it can serve as a valid tool in epidemiological studies to assess fruit and vegetable intake. PMID:22973322

  1. Reproducibility and Validity of the 6-Minute Walk Test Using the Gait Real-Time Analysis Interactive Lab in Patients with COPD and Healthy Elderly

    PubMed Central

    Meijer, Kenneth; Delbressine, Jeannet M.; Willems, Paul J.; Franssen, Frits M. E.; Wouters, Emiel F. M.; Spruit, Martijn A.

    2016-01-01

    Background The 6-minute walk test (6MWT) in a regular hallway is commonly used to assess functional exercise capacity in patients with chronic obstructive pulmonary disease (COPD). However, treadmill walking might provide additional advantages over overground walking, especially if virtual reality and self-paced treadmill walking are combined. Therefore, this study aimed to assess the reproducibility and validity of the 6MWT using the Gait Real-time Analysis Interactive Lab (GRAIL) in patients with COPD and healthy elderly. Methodology/Results Sixty-one patients with COPD and 48 healthy elderly performed two 6MWTs on the GRAIL. Patients performed two overground 6MWTs and healthy elderly performed one overground test. Differences between consecutive 6MWTs and the test conditions (GRAIL vs. overground) were analysed. Patients walked further in the second overground test (24.8 m, 95% CI 15.2–34.4 m, p<0.001) and in the second GRAIL test (26.8 m, 95% CI 13.9–39.6 m). Healthy elderly improved their second GRAIL test (49.6 m, 95% CI 37.0–62.3 m). The GRAIL 6MWT was reproducible (intra-class coefficients = 0.65–0.80). The best GRAIL 6-minute walk distance (6MWD) in patients was shorter than the best overground 6MWD (-27.3 ± 49.1 m, p<0.001). Healthy elderly walked further on the GRAIL than in the overground condition (23.6 ± 41.4 m, p<0.001). Validity of the GRAIL 6MWT was assessed and intra-class coefficient values ranging from 0.74–0.77 were found. Conclusion The GRAIL is a promising system to assess the 6MWD in patients with COPD and healthy elderly. The GRAIL 6MWD seems to be more comparable to the 6MWDs assessed overground than previous studies on treadmills have reported. Furthermore, good construct validity and reproducibility were established in assessing the 6MWD using the GRAIL in patients with COPD and healthy elderly. PMID:27607426

  2. Assessment of mastication in healthy children and children with cerebral palsy: a validity and consistency study.

    PubMed

    Remijn, L; Speyer, R; Groen, B E; Holtus, P C M; van Limbeek, J; Nijhuis-van der Sanden, M W G

    2013-05-01

    The aim of this study was to develop the Mastication Observation and Evaluation instrument for observing and assessing the chewing ability of children eating solid and lumpy foods. This study describes the process of item definition and item selection and reports the content validity, reproducibility and consistency of the instrument. In the developmental phase, 15 experienced speech therapists assessed item relevance and descriptions over three Delphi rounds. Potential items were selected based on the results from a literature review. At the initial Delphi round, 17 potential items were included. After three Delphi rounds, 14 items that regarded as providing distinctive value in assessment of mastication (consensus >75%) were included in the Mastication Observation and Evaluation instrument. To test item reproducibility and consistency, two experts and five students evaluated video recordings of 20 children (10 children with cerebral palsy aged 29-65 months and 10 healthy children aged 11-42 months) eating bread and a biscuit. Reproducibility was estimated by means of the intraclass correlation coefficient (ICC). With the exception of one item concerning chewing duration, all items showed good to excellent intra-observer agreement (ICC students: 0.73-1.0). With the exception of chewing duration and number of swallows, inter-observer agreement was fair to excellent for all items (ICC experts: 0.68-1.0 and ICC students: 0.42-1.0). Results indicate that this tool is a feasible instrument and could be used in clinical practice after further research is completed on the reliability of the tool. © 2013 Blackwell Publishing Ltd.

  3. Reproducibility and relative validity of food group intake in a food frequency questionnaire developed for Nepalese diet.

    PubMed

    Shrestha, Archana; Koju, Rajendra Prasad; Beresford, Shirley A A; Chan, Kwun Chuen Gary; Connell, Frederik A; Karmacharya, Biraj Man; Shrestha, Pramita; Fitzpatrick, Annette L

    2017-08-01

    We developed a food frequency questionnaire (FFQ) designed to measure the dietary practices of adult Nepalese. The present study examined the validity and reproducibility of the FFQ. To evaluate the reproducibility of the FFQ, 116 subjects completed two 115-item FFQ across a four-month interval. Six 24-h dietary recalls were collected (1 each month) to assess the validity of the FFQ. Seven major food groups and 23 subgroups were clustered from the FFQ based on macronutrient composition. Spearman correlation coefficients evaluating reproducibility for all food groups were greater than 0.5, with the exceptions of oil. The correlations varied from 0.41 (oil) to 0.81 (vegetables). All crude spearman coefficients for validity were greater than 0.5 except for dairy products, pizzas/pastas and sausage/burgers. The FFQ was found to be reliable and valid for ranking the intake of food groups for Nepalese dietary intake.

  4. Reproducibility of biomarkers in induced sputum and in serum from chronic smokers.

    PubMed

    Zuiker, Rob G J A; Kamerling, Ingrid M C; Morelli, Nicoletta; Calderon, Cesar; Boot, J Diderik; de Kam, Marieke; Diamant, Zuzana; Burggraaf, Jacobus; Cohen, Adam F

    2015-08-01

    Soluble inflammatory markers obtained from non-invasive airway sampling such as induced sputum may be useful biomarkers for targeted pharmaceutical interventions. However, before these soluble markers can be used as potential targets, their variability and reproducibility need to be established in distinct study populations. This study aimed to assess the reproducibility of biomarkers obtained from induced sputum and serum in chronic smokers and non-smokers. Sputum and serum samples were obtained from 16 healthy non-smokers and 16 asymptomatic chronic smokers (for both groups: 8M/8F, 30-52 years, FEV1 ≥80% pred.; ≥10 pack years for the smokers) on 2 separate visits 4-10 days apart. Soluble markers in serum and sputum were analysed by ELISA. The differences between smokers vs non-smokers were analysed with a t-test and variability was assessed on log-transformed data by a mixed model ANOVA. Analysable sputum samples could be obtained from all 32 subjects. In both study populations neutrophils and macrophages were the predominant cell types. Serum Pulmonary Surfactant Associated Protein D had favourable reproducibility criteria for reliability ratio (0.99), intra-subject coefficient of variation (11.2%) and the Bland Altman limits of agreement. Furthermore, chronic smokers, compared to non-smokers, had significantly higher sputum concentrations of IL-8 (1094.6 pg/mL vs 460.8 pg/mL, p = 0.006)), and higher serum concentrations of Pulmonary Surfactant Associated Protein D (110.9 pg/mL vs 64.7 pg/mL, p = 0.019), and lower concentrations of Serum Amyloid A (1352.4 pg/mL vs 2297.5 pg/mL, p = 0.022). Serum Pulmonary Surfactant Associated Protein D proved to be a biomarker that fulfilled the criteria for reproducibility in both study groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Development and validation of a food frequency questionnaire for dietary intake assessment among multi-ethnic primary school-aged children

    PubMed Central

    Fatihah, Fadil; Ng, Boon Koon; Hazwanie, Husin; Norimah, A Karim; Shanita, Safii Nik; Ruzita, Abd Talib; Poh, Bee Koon

    2015-01-01

    INTRODUCTION This study aimed to develop and validate a food frequency questionnaire (FFQ) to assess habitual diets of multi-ethnic Malaysian children aged 7–12 years. METHODS A total of 236 primary school children participated in the development of the FFQ and 209 subjects participated in the validation study, with a subsample of 30 subjects participating in the reproducibility study. The FFQ, consisting of 94 food items from 12 food groups, was compared with a three-day dietary record (3DR) as the reference method. The reproducibility of the FFQ was assessed through repeat administration (FFQ2), seven days after the first administration (FFQ1). RESULTS The results of the validation study demonstrated good acceptance of the FFQ. Mean intake of macronutrients in FFQ1 and 3DR correlated well, although the FFQ intake data tended to be higher. Cross-classification of nutrient intake between the two methods showed that < 7% of subjects were grossly misclassified. Moderate correlations noted between the two methods ranged from r = 0.310 (p < 0.001) for fat to r = 0.497 (p < 0.001) for energy. The reproducibility of the FFQ, as assessed by Cronbach’s alpha, ranged from 0.61 (protein) to 0.70 (energy, carbohydrates and fat). Spearman’s correlations between FFQ1 and FFQ2 ranged from rho = 0.333 (p = 0.072) for protein to rho = 0.479 (p < 0.01) for fat. CONCLUSION These findings indicate that the FFQ is valid and reliable for measuring the average intake of energy and macronutrients in a population of multi-ethnic children aged 7–12 years in Malaysia. PMID:26702165

  6. Residents-as-Teachers Publications: What Can Programs Learn From the Literature When Starting a New or Refining an Established Curriculum?

    PubMed

    Bree, Kelly K; Whicker, Shari A; Fromme, H Barrett; Paik, Steve; Greenberg, Larrie

    2014-06-01

    Teaching residents how to teach is a critical part of resident education because residents are often the major teachers of medical students. The importance of formal residents-as-teachers (RAT) curricula has been emphasized throughout the literature, yet not all residency programs have such a curriculum in place. The purpose of our study was to (1) review the medical education literature for established RAT curricula, (2) assess published curricula's reproducibility, (3) evaluate the type of outcomes achieved using the Kirkpatrick model of evaluation, and (4) identify curricula that training programs could feasibly adopt. We performed a literature review using PubMed, Medline, Scopus, PsycINFO, ERIC, and Embase. Key search words included residents, residents as teachers, teaching, internship and residency, and curriculum. In addition, a search of MedEdPORTAL was performed using the same key terms. Articles were evaluated based on the reproducibility of curricula and the assessment tools. Evaluation of educational outcomes was performed using the Kirkpatrick model. Thirty-nine articles were deemed appropriate for review. Interventions and evaluation techniques varied greatly. Only 1 article from the literature was deemed to have both curricula and assessments that would be fully reproducible by other programs. A literature review on RAT curricula found few articles that would be easily reproduced for residency programs that want to start or improve their own RAT curricula. It also demonstrated the difficulty and lack of rigorous outcome measurements for most curricula.

  7. Exhaled breath temperature in children: reproducibility and influencing factors.

    PubMed

    Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P

    2014-09-01

    This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.

  8. Reliability, agreement, and responsiveness of a 6-minute walk/run test in patients with heart disease.

    PubMed

    Berghmans, Danielle D; Lenssen, Antoine F; Bastiaenen, Carolien H; Ilhan, Mustafa; Lencer, Nicole H; Roox, George M

    2013-02-01

    The 6-minute walk test (6 MWT) is widely used to assess exercise tolerance in cardiac rehabilitation (CR). However, previous research shows it to be insufficiently responsive, especially for patients with a relatively high maximal exercise tolerance at baseline. We therefore designed a 6-minute walk/run test (6 MWRT), which has the same duration as the 6 MWT but allows running. The objective of this study was to determine the test-retest reproducibility and responsiveness of this 6 MWRT. Responsiveness was investigated in a prospective cohort study among a group of patients entering CR at Maastricht University Medical Center, with a cross-sectional part to assess the test-retest reproducibility. Test-retest reproducibility (reliability and agreement) was investigated using the intraclass correlation (ICC) and a Bland-Altman plot of two measurements implemented in the first week of rehabilitation. Responsiveness of the 6 MWT and the 6 MWRT was calculated using the standard response mean (SRM) over a 6-week period. The first reproducibility analysis included 34 patients, the second 22 patients. The ICCs were 0.935 and 0.906, respectively, with limits of agreement of ± 79 and ± 61 m. The responsiveness analysis included 27 patients. The SRM values were 0.83 for the 6 MWT and 0.71 for the 6 MWRT. Although the 6 MWRT is a reproducible test in CR, its responsiveness is not superior to that of the 6 MWT. We therefore prefer the conventional 6 MWT as an evaluative measurement in CR and advise against using the 6 MWRT as (evaluative) measurement in CR for this purpose.

  9. Proposal of a new classification of postoperative ileus based on its clinical impact-results of a global survey and preliminary evaluation in colorectal surgery.

    PubMed

    Venara, Aurélien; Slim, Karem; Regimbeau, Jean-Marc; Ortega-Deballon, Pablo; Vielle, Bruno; Lermite, Emilie; Meurette, Guillaume; Hamy, Antoine

    2017-06-01

    There is no consensual definition of postoperative ileus (POI), which leads to a lack of reproducibility. The aims of this study were (i) to propose and evaluate a classification of postoperative ileus based on its consequences and (ii) to assess the reproducibility of the classification. A national global survey was carried out according to the DELPHI method in order to create a classification of primary POI. The classification was subsequently tested on a cohort of patients who underwent colorectal surgery. Finally, a reproducibility test was performed in five teaching hospitals with junior and senior surgeons. A five-stage classification was proposed: grade A (least) to grade E (worst). For better differentiation, subcategories (D1/D2) were included. Overall, 173 patients were included who underwent colorectal surgery. Forty of them experienced primary postoperative ileus (23.1%). Grade A occurred in 10 cases, grade B in 10 cases, grade C in 14 cases, grade D1 in 2 cases, and grade D2 in 2 cases. POI-related death (grade E) occurred in 2 cases. Patients with grade A POI recovered their gastrointestinal function significantly faster than those with higher grades (p = 0.01), and were more likely to undergo laparoscopic surgery (p = 0.04). The Intraclass Correlation Coefficient (ICC) was 0.83 in the overall population, and 0.83 and 0.82 respectively in the junior and senior surgeon populations. This classification is easy to both use and reproduce. It will improve the reproducibility, evaluation, and assessment of POI. These preliminary results should be confirmed in a multi-centric international study.

  10. Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility?

    PubMed

    Goh, V; Halligan, S; Gartner, L; Bassett, P; Bartram, C I

    2006-07-01

    The purpose of this study was to determine if greater z-axis tumour coverage improves the reproducibility of quantitative colorectal cancer perfusion measurements using CT. A 65 s perfusion study was acquired following intravenous contrast administration in 10 patients with proven colorectal cancer using a four-detector row scanner. This was repeated within 48 h using identical technical parameters to allow reproducibility assessment. Quantitative tumour blood volume, blood flow, mean transit time and permeability measurements were determined using commercially available software (Perfusion 3.0; GE Healthcare, Waukesha, WI) for data obtained from a 5 mm z-axis tumour coverage, and from a 20 mm z-axis tumour coverage. Measurement reproducibility was assessed using Bland-Altman statistics, for a 5 mm z-axis tumour coverage, and 20 mm z-axis tumour coverage, respectively. The mean difference (95% limits of agreement) for blood volume, blood flow, mean transit time and permeability were 0.04 (-2.50 to +2.43) ml/100 g tissue; +8.80 (-50.5 to +68.0) ml/100 g tissue/min; -0.99 (-8.19 to +6.20) seconds; and +1.20 (-5.42 to +7.83) ml/100 g tissue/min, respectively, for a 5 mm coverage, and -0.04 (-2.61 to +2.53) ml/100 g tissue; +7.40 (-50.3 to +65.0) ml/100 g tissue/min; -2.46 (-12.61 to +7.69) seconds; and -0.23 (-8.31 to +7.85) ml/100 g tissue/min, respectively, for a 20 mm coverage, indicating similar levels of agreement. In conclusion, increasing z-axis coverage does not improve reproducibility of quantitative colorectal cancer perfusion measurements.

  11. Reproducibility of CT Perfusion Parameters in Liver Tumors and Normal Liver

    PubMed Central

    Ng, Chaan S.; Chandler, Adam G.; Wei, Wei; Herron, Delise H.; Anderson, Ella F.; Kurzrock, Razelle; Charnsangavej, Chusilp

    2011-01-01

    Purpose: To assess the reproducibility of computed tomographic (CT) perfusion measurements in liver tumors and normal liver and effects of motion and data acquisition time on parameters. Materials and Methods: Institutional review board approval and written informed consent were obtained for this prospective study. The study complied with HIPAA regulations. Two CT perfusion scans were obtained 2–7 days apart in seven patients with liver tumors with two scanning phases (phase 1: 30-second breath-hold cine; phase 2: six intermittent free-breathing cines) spanning 135 seconds. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability–surface area product (PS) for tumors and normal liver were calculated from phase 1 with and without rigid registration and, for combined phases 1 and 2, with manually and rigid-registered phase 2 images, by using deconvolution modeling. Variability was assessed with within-patient coefficients of variation (CVs) and Bland-Altman analyses. Results: For tumors, BF, BV, MTT, and PS values and reproducibility varied by analytical method, the former by up to 11%, 23%, 21%, and 138%, respectively. Median PS values doubled with the addition of phase 2 data to phase 1 data. The best overall reproducibility was obtained with rigidly registered phase 1 and phase 2 images, with within-patient CVs for BF, BV, MTT, and PS of 11.2%, 14.4%, 5.5% and 12.1%, respectively. Normal liver evaluations were similar, except with marginally lower variability. Conclusion: Absolute values and reproducibility of CT perfusion parameters were markedly influenced by motion and data acquisition time. PS, in particular, probably requires data acquisition beyond a single breath hold, for which motion-correction techniques are likely necessary. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110331/-/DC1 PMID:21788525

  12. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    PubMed

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  13. Reproducibility and Temporal Structure in Weekly Resting-State fMRI over a Period of 3.5 Years

    PubMed Central

    Choe, Ann S.; Jones, Craig K.; Joel, Suresh E.; Muschelli, John; Belegu, Visar; Caffo, Brian S.; Lindquist, Martin A.; van Zijl, Peter C. M.; Pekar, James J.

    2015-01-01

    Resting-state functional MRI (rs-fMRI) permits study of the brain’s functional networks without requiring participants to perform tasks. Robust changes in such resting state networks (RSNs) have been observed in neurologic disorders, and rs-fMRI outcome measures are candidate biomarkers for monitoring clinical trials, including trials of extended therapeutic interventions for rehabilitation of patients with chronic conditions. In this study, we aim to present a unique longitudinal dataset reporting on a healthy adult subject scanned weekly over 3.5 years and identify rs-fMRI outcome measures appropriate for clinical trials. Accordingly, we assessed the reproducibility, and characterized the temporal structure of, rs-fMRI outcome measures derived using independent component analysis (ICA). Data was compared to a 21-person dataset acquired on the same scanner in order to confirm that the values of the single-subject RSN measures were within the expected range as assessed from the multi-participant dataset. Fourteen RSNs were identified, and the inter-session reproducibility of outcome measures—network spatial map, temporal signal fluctuation magnitude, and between-network connectivity (BNC)–was high, with executive RSNs showing the highest reproducibility. Analysis of the weekly outcome measures also showed that many rs-fMRI outcome measures had a significant linear trend, annual periodicity, and persistence. Such temporal structure was most prominent in spatial map similarity, and least prominent in BNC. High reproducibility supports the candidacy of rs-fMRI outcome measures as biomarkers, but the presence of significant temporal structure needs to be taken into account when such outcome measures are considered as biomarkers for rehabilitation-style therapeutic interventions in chronic conditions. PMID:26517540

  14. Cervical vertebrae maturation method morphologic criteria: poor reproducibility.

    PubMed

    Nestman, Trenton S; Marshall, Steven D; Qian, Fang; Holton, Nathan; Franciscus, Robert G; Southard, Thomas E

    2011-08-01

    The cervical vertebrae maturation (CVM) method has been advocated as a predictor of peak mandibular growth. A careful review of the literature showed potential methodologic errors that might influence the high reported reproducibility of the CVM method, and we recently established that the reproducibility of the CVM method was poor when these potential errors were eliminated. The purpose of this study was to further investigate the reproducibility of the individual vertebral patterns. In other words, the purpose was to determine which of the individual CVM vertebral patterns could be classified reliably and which could not. Ten practicing orthodontists, trained in the CVM method, evaluated the morphology of cervical vertebrae C2 through C4 from 30 cephalometric radiographs using questions based on the CVM method. The Fleiss kappa statistic was used to assess interobserver agreement when evaluating each cervical vertebrae morphology question for each subject. The Kendall coefficient of concordance was used to assess the level of interobserver agreement when determining a "derived CVM stage" for each subject. Interobserver agreement was high for assessment of the lower borders of C2, C3, and C4 that were either flat or curved in the CVM method, but interobserver agreement was low for assessment of the vertebral bodies of C3 and C4 when they were either trapezoidal, rectangular horizontal, square, or rectangular vertical; this led to the overall poor reproducibility of the CVM method. These findings were reflected in the Fleiss kappa statistic. Furthermore, nearly 30% of the time, individual morphologic criteria could not be combined to generate a final CVM stage because of incompatible responses to the 5 questions. Intraobserver agreement in this study was only 62%, on average, when the inconclusive stagings were excluded as disagreements. Intraobserver agreement was worse (44%) when the inconclusive stagings were included as disagreements. For the group of subjects that could be assigned a CVM stage, the level of interobserver agreement as measured by the Kendall coefficient of concordance was only 0.45, indicating moderate agreement. The weakness of the CVM method results, in part, from difficulty in classifying the vertebral bodies of C3 and C4 as trapezoidal, rectangular horizontal, square, or rectangular vertical. This led to the overall poor reproducibility of the CVM method and our inability to support its use as a strict clinical guideline for the timing of orthodontic treatment. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  15. Relative validity and reproducibility of a food frequency questionnaire to assess dietary fiber intake in Danish adults.

    PubMed

    Vuholm, Stine; Lorenzen, Janne K; Kristensen, Mette

    2014-01-01

    Differences in habitual dietary fiber intake may modify effects of dietary fiber interventions, thus measurement of habitual dietary fiber intake is relevant to apply in intervention studies on fiber-rich foods, and food frequency questionnaire (FFQ) is a commonly used method. Rye bread is the major contributor of dietary fiber in the Danish population, and a nation-specific FFQ is therefore needed. The aim of this study was to assess the relative validity and reproducibility of a self-administered quantitative FFQ designed to assess total dietary fiber intake among Danish adults. In order to assess the relative validity of the FFQ, a total of 125 participants completed both a 7-day weighed dietary recording (DR) and an FFQ consisting of 60 questions. To evaluate the reproducibility of the FFQ, a sub-group of 12 participants subsequently completed an FFQ approximately 6 months later. Estimates of mean dietary fiber intake were 24.9±9.8 and 28.1±9.4 g/day when applying the FFQ and DR, respectively, where FFQ estimates were ~12% lower (p<0.001). Pearson's correlation coefficient between the estimated dietary fiber intake of the two methods was r=0.63 (p<0.001), and 62% of the participants were grouped into the same tertile of intake according to the two methods. The estimates of mean dietary intake of first and second FFQ were very similar (22.2±4.0 and 23.3±4.1 g/day, respectively, p=0.42) and showed a correlation of r=0.95 (95% CI 0.83-0.99). The developed FFQ showed moderate underestimation of dietary fiber intake (g/day), adequate ranking of subjects according to their dietary fiber intake, and good reproducibility. The FFQ is therefore believed to be a valuable tool for epidemiology and screening in human interventions, where intake of dietary fibers is of specific interest.

  16. Hierarchy of evidence relating to hand surgery in Brazilian orthopedic journals.

    PubMed

    Moraes, Vinícius Ynoe de; Belloti, João Carlos; Moraes, Fábio Ynoe de; Galbiatti, José Antonio; Palácio, Evandro Pereira; Santos, João Baptista Gomes Dos; Faloppa, Flávio

    2011-03-01

    There is no systematic assessment of the quality of scientific production in the specialty of hand surgery in our setting. This study aimed to systematically assess the status of evidence generation relating to hand surgery and to evaluate the reproducibility of the classification method based on an evidence pyramid. Secondary study conducted at Universidade Federal de São Paulo (Unifesp) and Faculdade Estadual de Medicina de Marília (Famema). Two researchers independently conducted an electronic database search for hand surgery studies published between 2000 and 2009 in the two main Brazilian orthopedic journals (Acta Ortopédica Brasileira and Revista Brasileira de Ortopedia). The studies identified were subsequently classified according to methodological design (systematic review of the literature, randomized clinical trial, cohort study, case-control study, case series and other studies) and evidence level (I to V). A total of 1,150 articles were evaluated, and 83 (7.2%) were included in the final analysis. Studies with evidence level IV (case series) accounted for 41 (49%) of the published papers. Studies with evidence level V (other studies) accounted for 12 (14.5%) of the papers. Only two studies (2.4%) were ranked as level I or II. The inter-rater reproducibility was excellent (k = 0.94). Hand surgery articles corresponded to less than one tenth of Brazilian orthopedic production. Studies with evidence level IV were the commonest type. The reproducibility of the classification stratified by evidence level was almost perfect.

  17. Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Using 82Rb-PET: Comparison with 13N-Ammonia

    PubMed Central

    Fakhri, Georges El

    2011-01-01

    82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2=0.843) and stress (r2=0.761). The Bland-Altman plots show no significant presence of proportional error at rest or stress, nor a dependence of the variations on the amplitude of the myocardial blood flow at rest or stress. A small systematic overestimation of 13N-ammonia MBF was observed with 82Rb at rest (0.129 ml/g/min) and the opposite, i.e., underestimation, at stress (0.22 ml/g/min). Conclusions Our results show that absolute quantitation of myocardial bloof flow is reproducible and accurate with 82Rb dynamic cardiac PET as compared to 13N-ammonia. The reproducibility of the quantitation approach itself was very good as well as inter-observer reproducibility. PMID:19525467

  18. A Novel Actinic Keratosis Field Assessment Scale for Grading Actinic Keratosis Disease Severity.

    PubMed

    Dréno, Brigitte; Cerio, Rino; Dirschka, Thomas; Nart, Ignasi Figueras; Lear, John T; Peris, Ketty; de Casas, Andrés Ruiz; Kaleci, Shaniko; Pellacani, Giovanni

    2017-10-02

    Actinic keratosis (AK) lesions are surrounded by field cancerization (areas of subclinical, non-visible sun damage). Existing AK grading tools rely on AK counts, which are not reproducible. An Actinic Keratosis Field Assessment Scale (AK-FAS) for grading the severity of AK/field was developed. Standardized photographs of patients representing the full range of AK severity were collected. Six investigators independently rated each photograph according to 3 criteria: AK area (total skin area affected by AK lesions), hyperkeratosis and sun damage. Inter-rater reproducibility was good for all 3 criteria. Validation of the AK-FAS showed good reproducibility for AK area and hyperkeratosis, even for dermatologists untrained on use of the scale. In conclusion, the AK-FAS is objective, easy to use and implement, and reproducible. It incorporates assessment of the entire field affected by AK instead of relying on lesion counts. Use of the AK-FAS may standardize AK diagnosis, making it relevant to routine clinical practice.

  19. Inter-study reproducibility of cardiovascular magnetic resonance tagging

    PubMed Central

    2013-01-01

    Background The aim of this study is to determine the test-retest reliability of the measurement of regional myocardial function by cardiovascular magnetic resonance (CMR) tagging using spatial modulation of magnetization. Methods Twenty-five participants underwent CMR tagging twice over 12 ± 7 days. To assess the role of slice orientation on strain measurement, two healthy volunteers had a first exam, followed by image acquisition repeated with slices rotated ±15 degrees out of true short axis, followed by a second exam in the true short axis plane. To assess the role of slice location, two healthy volunteers had whole heart tagging. The harmonic phase (HARP) method was used to analyze the tagged images. Peak midwall circumferential strain (Ecc), radial strain (Err), Lambda 1, Lambda 2, and Angle α were determined in basal, mid and apical slices. LV torsion, systolic and early diastolic circumferential strain and torsion rates were also determined. Results LV Ecc and torsion had excellent intra-, interobserver, and inter-study intra-class correlation coefficients (ICC range, 0.7 to 0.9). Err, Lambda 1, Lambda 2 and angle had excellent intra- and interobserver ICC than inter-study ICC. Angle had least inter-study reproducibility. Torsion rates had superior intra-, interobserver, and inter-study reproducibility to strain rates. The measurements of LV Ecc were comparable in all three slices with different short axis orientations (standard deviation of mean Ecc was 0.09, 0.18 and 0.16 at basal, mid and apical slices, respectively). The mean difference in LV Ecc between slices was more pronounced in most of the basal slices compared to the rest of the heart. Conclusions Intraobserver and interobserver reproducibility of all strain and torsion parameters was excellent. Inter-study reproducibility of CMR tagging by SPAMM varied between different parameters as described in the results above and was superior for Ecc and LV torsion. The variation in LV Ecc measurement due to altered slice orientation is negligible compared to the variation due to slice location. Trial registration This trial is registered as NCT00005487 at National Heart, Lung and Blood institute. PMID:23663535

  20. Three-dimensional surgical modelling with an open-source software protocol: study of precision and reproducibility in mandibular reconstruction with the fibula free flap.

    PubMed

    Ganry, L; Quilichini, J; Bandini, C M; Leyder, P; Hersant, B; Meningaud, J P

    2017-08-01

    Very few surgical teams currently use totally independent and free solutions to perform three-dimensional (3D) surgical modelling for osseous free flaps in reconstructive surgery. This study assessed the precision and technical reproducibility of a 3D surgical modelling protocol using free open-source software in mandibular reconstruction with fibula free flaps and surgical guides. Precision was assessed through comparisons of the 3D surgical guide to the sterilized 3D-printed guide, determining accuracy to the millimetre level. Reproducibility was assessed in three surgical cases by volumetric comparison to the millimetre level. For the 3D surgical modelling, a difference of less than 0.1mm was observed. Almost no deformations (<0.2mm) were observed post-autoclave sterilization of the 3D-printed surgical guides. In the three surgical cases, the average precision of fibula free flap modelling was between 0.1mm and 0.4mm, and the average precision of the complete reconstructed mandible was less than 1mm. The open-source software protocol demonstrated high accuracy without complications. However, the precision of the surgical case depends on the surgeon's 3D surgical modelling. Therefore, surgeons need training on the use of this protocol before applying it to surgical cases; this constitutes a limitation. Further studies should address the transfer of expertise. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Reproducibility of the anti-Factor Xa and anti-Factor IIa assays applied to enoxaparin solution.

    PubMed

    Martinez, Céline; Savadogo, Adama; Agut, Christophe; Anger, Pascal

    2013-01-01

    Enoxaparin is a widely used subcutaneously administered antithrombotic agent comprising a complex mixture of glycosaminoglycan chains. Owing to this complexity, its antithrombotic potency cannot be defined by physicochemical methods and is therefore evaluated using an enzymatic assay of anti-Xa and anti-IIa activity. Maintaining consistent anti-Xa activity in the final medicinal product allows physicians to ensure administration of the appropriate dosage to their patients. Bioassays are usually complex and display poorer reproducibility than physicochemical tests such as HPLC assays. Here, we describe the implementation of a common robotic platform and standard release potency testing procedures for enoxaparin sodium injection (Lovenox, Sanofi, Paris, France) products at seven quality control sites within Sanofi. Qualification and analytical procedures, as well as data handling, were optimized and harmonized to improve assay reproducibility. An inter-laboratory study was performed in routine-release conditions. The coefficients of variation for repeatability and reproducibility in assessments of anti-Xa activity were 1.0% and 1.2%, respectively. The tolerance interval in reproducibility precision conditions, expressed as percentage potency, was 96.8-103.2% of the drug product target of 10,000 IU/ml, comparing favorably with the United States of America Pharmacopeia specification (90-110%). The maximum difference between assays in two different laboratories is expected to be 4.1%. The reproducibility characteristics of anti-IIa activity assessments were found to be similar. These results demonstrate the effectiveness of the standardization process established and allow for further improvements to quality control in Lovenox manufacture. This process guarantees closeness between actual and target potencies, as exemplified by the results of release assays obtained during a three-year period. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Esthetic Evaluation of Implant Crowns and Peri-Implant Soft Tissue in the Anterior Maxilla: Comparison and Reproducibility of Three Different Indices.

    PubMed

    Tettamanti, Sandro; Millen, Christopher; Gavric, Jelena; Buser, Daniel; Belser, Urs C; Brägger, Urs; Wittneben, Julia-Gabriela

    2016-06-01

    A successful implant reconstruction with optimal esthetics consists of a visually pleasing prosthesis and complete and healthy surrounding soft tissue. In the current literature, numerous indices used to qualitatively assess esthetics have been described. However, studies comparing the indices and their reproducibility are scarce. The aim of this study was to compare three different esthetic indices for the evaluation of single implant-supported crowns. A total of 10 prosthodontists (P), 10 orthodontists (O), 10 general dentists (G), and 10 lay people (L) independently performed the same assessment using 30 photographs and corresponding casts with three different esthetic indices (Peri-Implant and Crown Index [PICI], Implant Crown Aesthetic Index [ICAI], "Pink Esthetic Score/White Esthetic Score [PES/WES]) and repeated the evaluations 4 weeks later. The PES/WES and the PICI showed significantly higher esthetic scores (pink, white, total) and clinical acceptance compared with the ICAI in all four groups and in both assessments. The highest intraobserver agreement was achieved using the PES/WES and the least with the ICAI. The mean Kappa per group ranged from 0.18 (group L with ICAI) to 0.63 (group G with PICI). In comparison with the ICAI, the PES/WES and PICI were more reproducible. Therefore, PES/WES and PICI seem to be more suitable as esthetic indices for single implant crowns. © 2015 Wiley Periodicals, Inc.

  3. Robust estimation of fractal measures for characterizing the structural complexity of the human brain: optimization and reproducibility

    PubMed Central

    Goñi, Joaquín; Sporns, Olaf; Cheng, Hu; Aznárez-Sanado, Maite; Wang, Yang; Josa, Santiago; Arrondo, Gonzalo; Mathews, Vincent P; Hummer, Tom A; Kronenberger, William G; Avena-Koenigsberger, Andrea; Saykin, Andrew J.; Pastor, María A.

    2013-01-01

    High-resolution isotropic three-dimensional reconstructions of human brain gray and white matter structures can be characterized to quantify aspects of their shape, volume and topological complexity. In particular, methods based on fractal analysis have been applied in neuroimaging studies to quantify the structural complexity of the brain in both healthy and impaired conditions. The usefulness of such measures for characterizing individual differences in brain structure critically depends on their within-subject reproducibility in order to allow the robust detection of between-subject differences. This study analyzes key analytic parameters of three fractal-based methods that rely on the box-counting algorithm with the aim to maximize within-subject reproducibility of the fractal characterizations of different brain objects, including the pial surface, the cortical ribbon volume, the white matter volume and the grey matter/white matter boundary. Two separate datasets originating from different imaging centers were analyzed, comprising, 50 subjects with three and 24 subjects with four successive scanning sessions per subject, respectively. The reproducibility of fractal measures was statistically assessed by computing their intra-class correlations. Results reveal differences between different fractal estimators and allow the identification of several parameters that are critical for high reproducibility. Highest reproducibility with intra-class correlations in the range of 0.9–0.95 is achieved with the correlation dimension. Further analyses of the fractal dimensions of parcellated cortical and subcortical gray matter regions suggest robustly estimated and region-specific patterns of individual variability. These results are valuable for defining appropriate parameter configurations when studying changes in fractal descriptors of human brain structure, for instance in studies of neurological diseases that do not allow repeated measurements or for disease-course longitudinal studies. PMID:23831414

  4. Reproducibility of airway luminal size in asthma measured by HRCT.

    PubMed

    Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A

    2017-10-01

    Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack of studies examining the reproducibility of high-resolution CT in asthma. The current study examined reproducibility of airway measurements. In stable well-controlled asthmatic subjects, it is possible to reproducibly image airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. Copyright © 2017 the American Physiological Society.

  5. Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification.

    PubMed

    Gu, Meng; Kim, Dong-Hyun; Mayer, Dirk; Sullivan, Edith V; Pfefferbaum, Adolf; Spielman, Daniel M

    2008-09-01

    A reproducibility study of proton MR spectroscopic imaging ((1)H-MRSI) of the human brain was conducted to evaluate the reliability of an automated 3D in vivo spectroscopic imaging acquisition and associated quantification algorithm. A PRESS-based pulse sequence was implemented using dualband spectral-spatial RF pulses designed to fully excite the singlet resonances of choline (Cho), creatine (Cre), and N-acetyl aspartate (NAA) while simultaneously suppressing water and lipids; 1% of the water signal was left to be used as a reference signal for robust data processing, and additional lipid suppression was obtained using adiabatic inversion recovery. Spiral k-space trajectories were used for fast spectral and spatial encoding yielding high-quality spectra from 1 cc voxels throughout the brain with a 13-min acquisition time. Data were acquired with an 8-channel phased-array coil and optimal signal-to-noise ratio (SNR) for the combined signals was achieved using a weighting based on the residual water signal. Automated quantification of the spectrum of each voxel was performed using LCModel. The complete study consisted of eight healthy adult subjects to assess intersubject variations and two subjects scanned six times each to assess intrasubject variations. The results demonstrate that reproducible whole-brain (1)H-MRSI data can be robustly obtained with the proposed methods.

  6. Framework for the quality assurance of 'omics technologies considering GLP requirements.

    PubMed

    Kauffmann, Hans-Martin; Kamp, Hennicke; Fuchs, Regine; Chorley, Brian N; Deferme, Lize; Ebbels, Timothy; Hackermüller, Jörg; Perdichizzi, Stefania; Poole, Alan; Sauer, Ursula G; Tollefsen, Knut E; Tralau, Tewes; Yauk, Carole; van Ravenzwaay, Ben

    2017-12-01

    'Omics technologies are gaining importance to support regulatory toxicity studies. Prerequisites for performing 'omics studies considering GLP principles were discussed at the European Centre for Ecotoxicology and Toxicology of Chemicals (ECETOC) Workshop Applying 'omics technologies in Chemical Risk Assessment. A GLP environment comprises a standard operating procedure system, proper pre-planning and documentation, and inspections of independent quality assurance staff. To prevent uncontrolled data changes, the raw data obtained in the respective 'omics data recording systems have to be specifically defined. Further requirements include transparent and reproducible data processing steps, and safe data storage and archiving procedures. The software for data recording and processing should be validated, and data changes should be traceable or disabled. GLP-compliant quality assurance of 'omics technologies appears feasible for many GLP requirements. However, challenges include (i) defining, storing, and archiving the raw data; (ii) transparent descriptions of data processing steps; (iii) software validation; and (iv) ensuring complete reproducibility of final results with respect to raw data. Nevertheless, 'omics studies can be supported by quality measures (e.g., GLP principles) to ensure quality control, reproducibility and traceability of experiments. This enables regulators to use 'omics data in a fit-for-purpose context, which enhances their applicability for risk assessment. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Reproducibility of the retinal vascular response to flicker light in Asians.

    PubMed

    Nguyen, Thanh T; Kreis, Andreas J; Kawasaki, Ryo; Wang, Jie Jin; Seifert, Bernd-U; Vilser, Walthard; Nagel, Edgar; Wong, Tien Y

    2009-12-01

    Dilation of retinal vessels in response to diffuse luminance flicker may reflect endothelial function. Although this has previously been shown to be reproducible in whites, there have been no similar data in Asians. We assess the reproducibility of repeated measurements of this response in Asians. Healthy Asians (n = 33) with normal vision and no history of glaucoma, age-related macular degeneration, cataract, or retinal arterial/venous occlusion participated in this study. Repeated measures from the same subjects were taken 30-60 min apart using the Dynamic Vessel Analyser (DVA, IMEDOS, Jena, Germany). Modification was made to the shape of the light source for Asian participants. Correlations of the first and second measures were assessed using Pearson correlation (R(2)), and agreement between the two measures was shown using Bland-Altman plots. After modification to the shape of the light source, almost perfect correlation was found between the 1st and 2nd measurements of baseline arteriolar (R(2) = 0.95) and venular diameters (R(2) = 0.98) of arteriolar maximum dilation (R(2) = 0.85). Substantially high correlation between the 1st and 2nd measurements of venular maximum dilation was found (R(2) = 0.80). Measurements of the dilation response of retinal vessels to diffuse luminance flicker an Asian sample using the DVA show high reproducibility for repeated measures over a short period of time. Such measurements may allow non-invasive quantification of endothelial function to study its association with systemic and ocular diseases.

  8. Variability of bioaccessibility results using seventeen different methods on a standard reference material, NIST 2710.

    PubMed

    Koch, Iris; Reimer, Kenneth J; Bakker, Martine I; Basta, Nicholas T; Cave, Mark R; Denys, Sébastien; Dodd, Matt; Hale, Beverly A; Irwin, Rob; Lowney, Yvette W; Moore, Margo M; Paquin, Viviane; Rasmussen, Pat E; Repaso-Subang, Theresa; Stephenson, Gladys L; Siciliano, Steven D; Wragg, Joanna; Zagury, Gerald J

    2013-01-01

    Bioaccessibility is a measurement of a substance's solubility in the human gastro-intestinal system, and is often used in the risk assessment of soils. The present study was designed to determine the variability among laboratories using different methods to measure the bioaccessibility of 24 inorganic contaminants in one standardized soil sample, the standard reference material NIST 2710. Fourteen laboratories used a total of 17 bioaccessibility extraction methods. The variability between methods was assessed by calculating the reproducibility relative standard deviations (RSDs), where reproducibility is the sum of within-laboratory and between-laboratory variability. Whereas within-laboratory repeatability was usually better than (<) 15% for most elements, reproducibility RSDs were much higher, indicating more variability, although for many elements they were comparable to typical uncertainties (e.g., 30% in commercial laboratories). For five trace elements of interest, reproducibility RSDs were: arsenic (As), 22-44%; cadmium (Cd), 11-41%; Cu, 15-30%; lead (Pb), 45-83%; and Zn, 18-56%. Only one method variable, pH, was found to correlate significantly with bioaccessibility for aluminum (Al), Cd, copper (Cu), manganese (Mn), Pb and zinc (Zn) but other method variables could not be examined systematically because of the study design. When bioaccessibility results were directly compared with bioavailability results for As (swine and mouse) and Pb (swine), four methods returned results within uncertainty ranges for both elements: two that were defined as simpler (gastric phase only, limited chemicals) and two were more complex (gastric + intestinal phases, with a mixture of chemicals).

  9. Test-retest reliability and validity of a web-based food-frequency questionnaire for adolescents aged 13-14 to be used in the Norwegian Mother and Child Cohort Study (MoBa).

    PubMed

    Overby, Nina Cecilie; Johannesen, Elisabeth; Jensen, Grete; Skjaevesland, Anne-Kirsti; Haugen, Margaretha

    2014-01-01

    The assessment of food intake is challenging and prone to errors; it is therefore important to consider the reliability and validity of the assessment methods. The aim of this study was to analyze the reproducibility and validity of a developed food-frequency questionnaire (FFQ) for use among adolescents. In total, 58 students (aged 13-14) from four different schools in the southern part of Norway participated in the reproducibility study of filling out the FFQ 4 weeks apart. In addition, 93 students participated in the relative validity study where the FFQ was compared to 2×24-hour dietary recalls, while 92 students participated in the absolute validity study where the intakes of fatty acids and vitamin D from the FFQ were compared to fatty acids and 25-hydroxy-vitamin D3 in whole blood. The median Spearman correlation coefficient for all nutrients in the test-retest reliability study was 0.57. The median Spearman correlation for all nutrients in the relative validity study was 0.26, while the correlations coefficients were low in the absolute validity study with n-3 fatty acid coefficients ranging from 0.05 to 0.25, and absent for vitamin D (r=0.000). The test-retest reproducibility was considered good, the relative validity was considered poor to good, and the absolute validity was considered poor. However, the results are comparable to other studies among adolescents.

  10. Assessment of orthodontic treatment need: a comparison of study models and facial photographs.

    PubMed

    Sherlock, Joseph M; Cobourne, Martyn T; McDonald, Fraser

    2008-02-01

    The current study aims to examine how orthodontic treatment need is prioritized depending upon whether dental study models or facial photographs are used as the means of assessment. A group of three orthodontists and three postgraduate orthodontic students assessed: (i) dental attractiveness; and (ii) need for orthodontic treatment in 40 subjects (19 males, 21 females). The 40 subjects displayed a range of malocclusions. Separate assessments were made from study models and facial photographs. There was a bias towards higher scores for dental attractiveness from facial photographs compared with assessment of study casts, for all examiners. This was statistically significant for five of the six examiners (P = 0.001-0.101). The need for orthodontic treatment was rated as 20% higher from study models compared with facial photographs (P < 0.001); overall the level of need for orthodontic treatment was rated as 18.9% higher from study models compared with facial photographs (P < 0.001). Reproducibility analyses showed that there was a considerable variation in the intra- and inter-examiner agreement. This study shows that a group of three orthodontists and three postgraduate students in orthodontics: (i) rated orthodontic treatment need higher from study models compared with facial photographs and; (ii) rated dental attractiveness higher from facial photographs compared with study models. It is suggested that the variable intra-examiner agreement may result from the assessment of orthodontic treatment need and dental attractiveness in the absence of any specific assessment criteria. The poor reproducibility of assessment of orthodontic treatment need and dental attractiveness in the absence of strict criteria may suggest the need to use an appropriate index.

  11. Intra- and inter-observer agreement in MRI assessment of rotator cuff healing using the Sugaya classification 10years after surgery.

    PubMed

    Niglis, L; Collin, P; Dosch, J-C; Meyer, N; Kempf, J-F

    2017-10-01

    The long-term outcomes of rotator cuff repair are unclear. Recurrent tears are common, although their reported frequency varies depending on the type and interpretation challenges of the imaging method used. The primary objective of this study was to assess the intra- and inter-observer reproducibility of the MRI assessment of rotator cuff repair using the Sugaya classification 10years after surgery. The secondary objective was to determine whether poor reproducibility, if found, could be improved by using a simplified yet clinically relevant classification. Our hypothesis was that reproducibility was limited but could be improved by simplifying the classification. In a retrospective study, we assessed intra- and inter-observer agreement in interpreting 49 magnetic resonance imaging (MRI) scans performed 10years after rotator cuff repair. These 49 scans were taken at random among 609 cases that underwent re-evaluation, with imaging, for the 2015 SoFCOT symposium on 10-year and 20-year clinical and anatomical outcomes of rotator cuff repair for full-thickness tears. Each of three observers read each of the 49 scans on two separate occasions. At each reading, they assessed the supra-spinatus tendon according to the Sugaya classification in five types. Intra-observer agreement for the Sugaya type was substantial (κ=0.64) but inter-observer agreement was only fair (κ=0.39). Agreement improved when the five Sugaya types were collapsed into two categories (1-2-3 and 4-5) (intra-observer κ=0.74 and inter-observer κ=0.68). Using the Sugaya classification to assess post-operative rotator cuff healing was associated with substantial intra-observer and fair inter-observer agreement. A simpler classification into two categories improved agreement while remaining clinically relevant. II, prospective randomised low-power study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Londrina Activities of Daily Living Protocol: Reproducibility, Validity, and Reference Values in Physically Independent Adults Age 50 Years and Older.

    PubMed

    Paes, Thaís; Belo, Letícia Fernandes; da Silva, Diego Rodrigues; Morita, Andrea Akemi; Donária, Leila; Furlanetto, Karina Couto; Sant'Anna, Thaís; Pitta, Fabio; Hernandes, Nidia Aparecida

    2017-03-01

    It is important to assess activities of daily living (ADL) in older adults due to impairment of independence and quality of life. However, there is no objective and standardized protocol available to assess this outcome. Thus, the aim of this study was to verify the reproducibility and validity of a new protocol for ADL assessment applied in physically independent adults age ≥50 y, the Londrina ADL protocol, and to establish an equation to predict reference values of the Londrina ADL protocol. Ninety-three physically independent adults age ≥50 y had their performance in ADL evaluated by registering the time spent to conclude the protocol. The protocol was performed twice. The 6-min walk test, which assesses functional exercise capacity, was used as a validation criterion. A multiple linear regression model was applied, including anthropometric and demographic variables that correlated with the protocol, to establish an equation to predict the protocol's reference values. In general, the protocol was reproducible (intraclass correlation coefficient 0.91). The average difference between the first and second protocol was 5.3%. The new protocol was valid to assess ADL performance in the studied subjects, presenting a moderate correlation with the 6-min walk test (r = -0.53). The time spent to perform the protocol correlated significantly with age (r = 0.45) but neither with weight (r = -0.17) nor with height (r = -0.17). A model of stepwise multiple regression including sex and age showed that age was the only determinant factor to the Londrina ADL protocol, explaining 21% ( P < .001) of its variability. The derived reference equation was: Londrina ADL protocol pred (s) = 135.618 + (3.102 × age [y]). The Londrina ADL protocol was reproducible and valid in physically independent adults age ≥50 y. A reference equation for the protocol was established including only age as an independent variable (r 2 = 0.21), allowing a better interpretation of the protocol's results in clinical practice. Copyright © 2017 by Daedalus Enterprises.

  13. The reproducibility of 31-phosphorus MRS measures of muscle energetics at 3 Tesla in trained men.

    PubMed

    Edwards, Lindsay M; Tyler, Damian J; Kemp, Graham J; Dwyer, Renee M; Johnson, Andrew; Holloway, Cameron J; Nevill, Alan M; Clarke, Kieran

    2012-01-01

    Magnetic resonance spectroscopy (MRS) provides an exceptional opportunity for the study of in vivo metabolism. MRS is widely used to measure phosphorus metabolites in trained muscle, although there are no published data regarding its reproducibility in this specialized cohort. Thus, the aim of this study was to assess the reproducibility of (31)P-MRS in trained skeletal muscle. We recruited fifteen trained men (VO(2)peak = 4.7±0.8 L min(-1)/58±8 mL kg(-1) min(-1)) and performed duplicate MR experiments during plantar flexion exercise, three weeks apart. Measures of resting phosphorus metabolites were reproducible, with 1.7 mM the smallest detectable difference in phosphocreatine (PCr). Measures of metabolites during exercise were less reliable: exercising PCr had a coefficient of variation (CV) of 27% during exercise, compared with 8% at rest. Estimates of mitochondrial function were variable, but experimentally useful. The CV of PCr(1/2t) was 40%, yet much of this variance was inter-subject such that differences of <20% were detectable with n = 15, given a significance threshold of p<0.05. 31-phosphorus MRS provides reproducible and experimentally useful measures of phosphorus metabolites and mitochondrial function in trained human skeletal muscle.

  14. Development, reproducibility and validity of the food frequency questionnaire in the Poland arm of the Prospective Urban and Rural Epidemiological (PURE) study.

    PubMed

    Dehghan, M; Ilow, R; Zatonska, K; Szuba, A; Zhang, X; Mente, A; Regulska-Ilow, B

    2012-06-01

    A food frequency questionnaire (FFQ) is the most commonly used method in large epidemiological studies. The validation of an FFQ is essential for specific populations because foods are culture-dependent. The present study aimed to develop an FFQ and evaluate its validity and reproducibility in estimating the intake of nutrients in urban and rural areas of Poland. Adult participants (n = 146) in the Polish arm of the ongoing Prospective Urban and Rural Epidemiological (PURE) study completed FFQs on two occasions, as well as four 24-h dietary recalls (DRs) during a 12-month period. Correlation coefficients (r) and de-attenuated correlation coefficients between dietary recalls and both FFQs were calculated for selected macro- and micronutrients. Agreement between the two methods was evaluated by classification into quartiles and the Bland-Altman method. Reproducibility was assessed by the intra-class correlation coefficient (ICC). The final food list contained 134 food items. For urban participants, FFQ2 generally underestimated energy, protein and fat compared to the FFQ1 and mean of DRs. In rural areas, compared to DRs, both FFQs overestimated energy and macronutrients. For both urban and rural settings, de-attenuated correlation exceeded 0.4 for almost all nutrients and the exact agreement in quartile categorisation was >66%. When assessing repeatability, ICC varied from 0.39-0.63 in an urban setting and 0.19-0.45 in a rural setting. This 134-item FFQ has good validity and reproducibility in relation to the reference method and can be used to rank individuals based on their macro- and micronutrient intake. © 2012 The Authors. Journal of Human Nutrition and Dietetics © 2012 The British Dietetic Association Ltd.

  15. An inter-observer Ki67 reproducibility study applying two different assessment methods: on behalf of the Danish Scientific Committee of Pathology, Danish breast cancer cooperative group (DBCG).

    PubMed

    Laenkholm, Anne-Vibeke; Grabau, Dorthe; Møller Talman, Maj-Lis; Balslev, Eva; Bak Jylling, Anne Marie; Tabor, Tomasz Piotr; Johansen, Morten; Brügmann, Anja; Lelkaitis, Giedrius; Di Caterino, Tina; Mygind, Henrik; Poulsen, Thomas; Mertz, Henrik; Søndergaard, Gorm; Bruun Rasmussen, Birgitte

    2018-01-01

    In 2011, the St. Gallen Consensus Conference introduced the use of pathology to define the intrinsic breast cancer subtypes by application of immunohistochemical (IHC) surrogate markers ER, PR, HER2 and Ki67 with a specified Ki67 cutoff (>14%) for luminal B-like definition. Reports concerning impaired reproducibility of Ki67 estimation and threshold inconsistency led to the initiation of this quality assurance study (2013-2015). The aim of the study was to investigate inter-observer variation for Ki67 estimation in malignant breast tumors by two different quantification methods (assessment method and count method) including measure of agreement between methods. Fourteen experienced breast pathologists from 12 pathology departments evaluated 118 slides from a consecutive series of malignant breast tumors. The staining interpretation was performed according to both the Danish and Swedish guidelines. Reproducibility was quantified by intra-class correlation coefficient (ICC) and Lights Kappa with dichotomization of observations at the larger than (>) 20% threshold. The agreement between observations by the two quantification methods was evaluated by Bland-Altman plot. For the fourteen raters the median ranged from 20% to 40% by the assessment method and from 22.5% to 36.5% by the count method. Light's Kappa was 0.664 for observation by the assessment method and 0.649 by the count method. The ICC was 0.82 (95% CI: 0.77-0.86) by the assessment method vs. 0.84 (95% CI: 0.80-0.87) by the count method. Although the study in general showed a moderate to good inter-observer agreement according to both ICC and Lights Kappa, still major discrepancies were identified in especially the mid-range of observations. Consequently, for now Ki67 estimation is not implemented in the DBCG treatment algorithm.

  16. Ultrasound anatomy in the normal neonatal and infant foot: an anatomic introduction to ultrasound assessment of foot deformities.

    PubMed

    Aurell, Y; Johansson, A; Hansson, G; Wallander, H; Jonsson, K

    2002-09-01

    The aim of this study was to establish guidelines for US assessment of the talo-crural, the talo-navicular and the calcaneo-cuboid joints during the first year of life, which could serve as a reference while studying foot deformities. The feet of 54 healthy children were examined at birth and at the age of 4, 7 and 12 months by using three easily defined and reproducible US projections. With a medial projection the relation of the navicular in relation to the medial malleolus and the head of the talus was studied. A lateral projection revealed the calcaneo-cuboid relationship and a dorsal projection the talo-navicular alignment in the sagittal plane. Normal values for measurements of these cartilaginous relationships were established for the different age groups. Intra- and inter-observer reliability was assessed and found to be acceptable ( r=0.53-0.90, Pearson correlation coefficient). With US it is possible to obtain reproducible planes of investigation that give reliable information about the talo-crural, the talo-navicular and the calcaneo-cuboid relationships during the first year of life.

  17. Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty.

    PubMed

    Daigre, Justin; Berlet, Gregory; Van Dyke, Bryan; Peterson, Kyle S; Santrock, Robert

    2017-04-01

    Implant survivorship is dependent on accuracy of implantation and successful soft tissue balancing. System instrumentation for total ankle arthroplasty implantation has a key influence on surgeon accuracy and reproducibility. The purpose of this study was to determine the accuracy and reproducibility of implant position with patient-specific guides for total ankle arthroplasty across multiple surgeons at multiple facilities. This retrospective, multicenter study included 44 patients who received a total ankle implant (INBONE II Total Ankle System; Wright Medical Technology, Memphis, TN) using PROPHECY patient-specific guides from January 2012 to December 2014. Forty-four patients with an average age of 63.0 years underwent total ankle arthroplasty using this preoperative patient-specific system. Preoperative computed tomography (CT) scans were obtained to assess coronal plane deformity, assess mechanical and anatomic alignment, and build patient-specific guides that referenced bony anatomy. The mean preoperative coronal deformity was 4.6 ± 4.6 degrees (range, 14 degrees varus to 17 degrees valgus). The first postoperative weightbearing radiographs were used to measure coronal and sagittal alignment of the implant vs the anatomic axis of the tibia. In 79.5% of patients, the postoperative implant position of the tibia corresponded to the preoperative plan of the tibia within 3 degrees of the intended target, within 4 degrees in 88.6% of patients, and within 5 degrees in 100% of patients. The tibial component coronal size was correctly predicted in 98% of cases, whereas the talar component was correctly predicted in 80% of cases. The use of patient-specific instrumentation for total ankle arthroplasty provided reliable alignment and reproducibility in the clinical situation similar to that shown in cadaveric testing. This study has shown that the preoperative patient-specific instrumentation provided for accuracy and reproducibility of ankle arthroplasty implantation in a cohort across multiple surgeons and facilities. Level III, retrospective comparative series.

  18. Kinetic modeling and long-term test-retest reproducibility of the mGluR5 PET tracer 18F-FPEB in human brain.

    PubMed

    Leurquin-Sterk, Gil; Postnov, Andrey; de Laat, Bart; Casteels, Cindy; Celen, Sofie; Crunelle, Cleo L; Bormans, Guy; Koole, Michel; Van Laere, Koen

    2016-04-01

    (18)F-FPEB is a promising PET tracer for studying the metabotropic glutamate subtype 5 receptor (mGluR5) expression in neuropsychiatric disorders. To assess the potential of (18)F-FPEB for longitudinal mGluR5 evaluation in patient studies, we evaluated the long-term test-retest reproducibility using various kinetic models in the human brain. Nine healthy volunteers underwent consecutive scans separated by a 6-month period. Dynamic PET was combined with arterial sampling and radiometabolite analysis. Total distribution volume (V(T)) and nondisplaceable binding potential (BP(ND)) were derived from a two-tissue compartment model without constraints (2TCM) and with constraining the K(1)/k(2) ratio to the value of either cerebellum (2TCM-CBL) or pons (2TCM-PONS). The effect of fitting different functions to the tracer parent fractions and reducing scan duration were assessed. Regional absolute test-retest variability (aTRV), coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were computed. The 2TCM-CBL showed best fits. The mean 6-month aTRV of V(T) ranged from 8 to 13% (CR < 25%) with ICC > 0.6 for all kinetic models. BPND from 2TCM-CBL with a sigmoid fit for the parent fractions showed the best reproducibility, with aTRV ≤ 7% (CR < 16%) and ICC > 0.9 in most regions. Reducing the scan duration from 90 to 60 min did not affect reproducibility. These results demonstrate for the first time that (18)F-FPEB brain PET has good long-term reproducibility, therefore validating its use to monitor mGluR5 expression in longitudinal clinical studies. We suggest a 2TCM-CBL with fitting a sigmoid function to the parent fractions to be optimal for this tracer. © 2016 Wiley Periodicals, Inc.

  19. Handgrip force steadiness in young and older adults: a reproducibility study.

    PubMed

    Blomkvist, Andreas W; Eika, Fredrik; de Bruin, Eling D; Andersen, Stig; Jorgensen, Martin

    2018-04-02

    Force steadiness is a quantitative measure of the ability to control muscle tonus. It is an independent predictor of functional performance and has shown to correlate well with different degrees of motor impairment following stroke. Despite being clinically relevant, few studies have assessed the validity of measuring force steadiness. The aim of this study was to explore the reproducibility of handgrip force steadiness, and to assess age difference in steadiness. Intrarater reproducibility (the degree to which a rating gives consistent result on separate occasions) was investigated in a test-retest design with seven days between sessions. Ten young and thirty older adults were recruited and handgrip steadiness was tested at 5%, 10% and 25% of maximum voluntary contraction (MVC) using Nintendo Wii Balance Board (WBB). Coefficients of variation were calculated from the mean force produced (CVM) and the target force (CVT). Area between the force curve and the target force line (Area) was also calculated. For the older adults we explored reliability using intraclass correlation coefficient (ICC) and agreement using standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD). A systematic improvement in handgrip steadiness was found between sessions for all measures (CVM, CVT, Area). CVM and CVT at 5% of MVC showed good to high reliability, while Area had poor reliability for all percentages of MVC. Averaged ICC for CVM, CVT and Area was 0.815, 0.806 and 0.464, respectively. Averaged ICC on 5%, 10%, and 25% of MVC was 0.751, 0.667 and 0.668, respectively. Measures of agreement showed similar trends with better results for CVM and CVT than for Area. Young adults had better handgrip steadiness than older adults across all measures. The CVM and CVT measures demonstrated good reproducibility at lower percentages of MVC using the WBB, and could become relevant measures in the clinical setting. The Area measure had poor reproducibility. Young adults have better handgrip steadiness than old adults.

  20. Improving the quality of preclinical research echocardiography: Observations, training and guidelines for measurement.

    PubMed

    Donner, Daniel G; Kiriazis, Helen; Du, Xiao-Jun; Marwick, Thomas H; McMullen, Julie R

    2018-04-20

    Informal training in preclinical research may be a contributor to the poor reproducibility of preclinical cardiology research and low rates of translation into clinical research and practice. Mouse echocardiography is a widely used technique to assess cardiac structure and function in drug intervention studies using disease models. The inter-observer variability (IOV) of clinical echocardiographic measurements has been shown to improve with formalized training, but preclinical echocardiography lacks similarly critical standardization of training. The aims of this investigation were to assess the IOV of echocardiographic measurements from studies in mice, and address any technical impediments to reproducibility by implementing standardized guidelines through formalized training. In this prospective, single-site, observational cohort study, 13 scientists performing preclinical echocardiographic image analysis were assessed for measurement of short-axis M-mode-derived dimensions and calculated left ventricular mass (LVMass). Ten M-mode images of mouse hearts acquired and analyzed by an expert researcher with a spectrum of LVMass were selected for assessment, and validated by autopsy weight. Following the initial observation, a structured formal training program was introduced, and accuracy and reproducibility were re-evaluated. Mean absolute percentage error (MAPE) for Expert-calculated LVMass was 6{plus minus}4% compared to autopsy LVMass, and 25{plus minus}21% for participants before training. Standardized formal training improved participant MAPE by approximately 30% relative to expert-calculated LVMass (p<0.001). Participants initially categorized with high-range error (25-45%) improved to low-moderate error ranges (<15-25%). This report reveals an example of technical skill training insufficiency likely endemic to preclinical research and provides validated guidelines for echocardiographic measurement for adaptation to formalized in-training programs.

  1. Composting in small laboratory pilots: Performance and reproducibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lashermes, G.; Barriuso, E.; Le Villio-Poitrenaud, M.

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer We design an innovative small-scale composting device including six 4-l reactors. Black-Right-Pointing-Pointer We investigate the performance and reproducibility of composting on a small scale. Black-Right-Pointing-Pointer Thermophilic conditions are established by self-heating in all replicates. Black-Right-Pointing-Pointer Biochemical transformations, organic matter losses and stabilisation are realistic. Black-Right-Pointing-Pointer The organic matter evolution exhibits good reproducibility for all six replicates. - Abstract: Small-scale reactors (<10 l) have been employed in composting research, but few attempts have assessed the performance of composting considering the transformations of organic matter. Moreover, composting at small scales is often performed by imposing a fixed temperature, thus creatingmore » artificial conditions, and the reproducibility of composting has rarely been reported. The objectives of this study are to design an innovative small-scale composting device safeguarding self-heating to drive the composting process and to assess the performance and reproducibility of composting in small-scale pilots. The experimental setup included six 4-l reactors used for composting a mixture of sewage sludge and green wastes. The performance of the process was assessed by monitoring the temperature, O{sub 2} consumption and CO{sub 2} emissions, and characterising the biochemical evolution of organic matter. A good reproducibility was found for the six replicates with coefficients of variation for all parameters generally lower than 19%. An intense self-heating ensured the existence of a spontaneous thermophilic phase in all reactors. The average loss of total organic matter (TOM) was 46% of the initial content. Compared to the initial mixture, the hot water soluble fraction decreased by 62%, the hemicellulose-like fraction by 68%, the cellulose-like fraction by 50% and the lignin-like fractions by 12% in the final compost. The TOM losses, compost stabilisation and evolution of the biochemical fractions were similar to observed in large reactors or on-site experiments, excluding the lignin degradation, which was less important than in full-scale systems. The reproducibility of the process and the quality of the final compost make it possible to propose the use of this experimental device for research requiring a mass reduction of the initial composted waste mixtures.« less

  2. Automated estimation of image quality for coronary computed tomographic angiography using machine learning.

    PubMed

    Nakanishi, Rine; Sankaran, Sethuraman; Grady, Leo; Malpeso, Jenifer; Yousfi, Razik; Osawa, Kazuhiro; Ceponiene, Indre; Nazarat, Negin; Rahmani, Sina; Kissel, Kendall; Jayawardena, Eranthi; Dailing, Christopher; Zarins, Christopher; Koo, Bon-Kwon; Min, James K; Taylor, Charles A; Budoff, Matthew J

    2018-03-23

    Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

  3. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    PubMed

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The accuracy and reproducibility of video assessment in the pitch-side management of concussion in elite rugby.

    PubMed

    Fuller, G W; Kemp, S P T; Raftery, M

    2017-03-01

    To investigate the accuracy and reliability of side-line video review of head impact events to aid identification of concussion in elite sport. Diagnostic accuracy and inter-rater agreement study. Immediate care, match day and team doctors involved in the 2015 Rugby Union World Cup viewed 20 video clips showing broadcaster's footage of head impact events occurring during elite Rugby matches. Subjects subsequently recorded whether any criteria warranting permanent removal from play or medical room head injury assessment were present. The accuracy of these ratings were compared to consensus expert opinion by calculating mean sensitivity and specificity across raters. The reproducibility of doctor's decisions was additionally assessed using raw agreement and Gwets AC1 chance corrected agreement coefficient. Forty rugby medicine doctors were included in the study. Compared to the expert reference standard overall sensitivity and specificity of doctors decisions were 77.5% (95% CI 73.1-81.5%) and 53.3% (95% CI 48.2-58.2%) respectively. Overall there was raw agreement of 67.8% (95% CI 57.9-77.7%) between doctors across all video clips. Chance corrected Gwets AC1 agreement coefficient was 0.39 (95% CI 0.17-0.62), indicating fair agreement. Rugby World Cup doctors' demonstrated moderate accuracy and fair reproducibility in head injury event decision making when assessing video clips of head impact events. The use of real-time video may improve the identification, decision making and management of concussion in elite sports. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Symmetry of proprioceptive sense in female soccer players.

    PubMed

    Iwańska, Dagmara; Karczewska, Magdalena; Madej, Anna; Urbanik, Czesław

    2015-01-01

    The purpose of the study was to assess the symmetry of proprioceptive sense among female soccer players when trying to reproduce isometric knee extensions (right and left) and to analyze the impact of a given level of muscle force on proprioception. The study involved 12 soccer players aged 19.5 ± 2.65 years. Soccer players performed a control measurement of a maximum 3s (knee at the 90°) position in the joint. Subsequently, 70%, 50%, and 30% of the maximum voluntary contraction (MVC) were all calculated and then reproduced by each subject with feedback. Next, the players reproduced the predefined muscle contraction values in three sequences: A - 50%, 70%, 30%; B - 50%, 30%, 70%; C - 70%, 30%, 50% of MVC without visual control. In every sequence, the participants found obtaining the value of 30% of MVC the most difficult. The value they reproduced most accurately was 70% of MVC. Both trial II and trial III demonstrated that the symmetry index SI significantly differed from values considered acceptable (SIRa). In each successive sequence the largest asymmetry occurred while reproducing the lowest values of MVC (30%) (p < 0.05). High level of prioprioceptive sense is important to soccer players due to the extensive overload associated with dynamics stops or changes in direction while running. Special attention should be paid to develop skills in sensing force of varying levels. It was much harder to reproduce the predefined values if there was no feedback.

  6. Reliability and discriminatory power of methods for dental plaque quantification

    PubMed Central

    RAGGIO, Daniela Prócida; BRAGA, Mariana Minatel; RODRIGUES, Jonas Almeida; FREITAS, Patrícia Moreira; IMPARATO, José Carlos Pettorossi; MENDES, Fausto Medeiros

    2010-01-01

    Objective This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. Material and Methods Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. Results Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. Conclusions The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque. PMID:20485931

  7. Cervical vertebral maturation as a biologic indicator of skeletal maturity.

    PubMed

    Santiago, Rodrigo César; de Miranda Costa, Luiz Felipe; Vitral, Robert Willer Farinazzo; Fraga, Marcelo Reis; Bolognese, Ana Maria; Maia, Lucianne Cople

    2012-11-01

    To identify and review the literature regarding the reliability of cervical vertebrae maturation (CVM) staging to predict the pubertal spurt. The selection criteria included cross-sectional and longitudinal descriptive studies in humans that evaluated qualitatively or quantitatively the accuracy and reproducibility of the CVM method on lateral cephalometric radiographs, as well as the correlation with a standard method established by hand-wrist radiographs. The searches retrieved 343 unique citations. Twenty-three studies met the inclusion criteria. Six articles had moderate to high scores, while 17 of 23 had low scores. Analysis also showed a moderate to high statistically significant correlation between CVM and hand-wrist maturation methods. There was a moderate to high reproducibility of the CVM method, and only one specific study investigated the accuracy of the CVM index in detecting peak pubertal growth. This systematic review has shown that the studies on CVM method for radiographic assessment of skeletal maturation stages suffer from serious methodological failures. Better-designed studies with adequate accuracy, reproducibility, and correlation analysis, including studies with appropriate sensitivity-specificity analysis, should be performed.

  8. Ptosis assessment spectacles: a new method of measuring lid position and movement in children.

    PubMed

    Khandwala, Mona; Dey, Sarju; Harcourt, Cassie; Wood, Clive; Jones, Carole A

    2011-01-01

    Accurate assessment of eyelid position and movement is vital in planning the surgical correction of ptosis. Conventional measurements taken using a millimeter ruler are considered the gold standard, although in young children this can be a difficult procedure. The authors have designed ptosis assessment spectacles with a measuring millimeter scale marked on the center of the lens to facilitate accurate assessment of eyelid position and function in children. The purpose of the study was to assess the accuracy and reproducibility of eyelid measurement using these ptosis assessment spectacles. Fifty-two children aged 2-12 years were recruited in this study. Each child underwent 2 sets of measurements. The first was undertaken by an ophthalmologist in the conventional manner using a ruler, and the second set made with ptosis assessment spectacles. On each occasion the palpebral aperture, skin crease, and levator function were recorded in millimeters. A verbal analog scale was used to assess parent satisfaction with each method. Clinically acceptable reproducibility was shown with the ruler and the spectacles for all measurements: palpebral aperture, skin crease, and levator function. Parents significantly preferred the glasses for measurement, as compared with the ruler (p < 0.05). The spectacles are as accurate as conventional methods of measurement, but are easier to use. Children tolerate these spectacles well, and most parents preferred them to the ruler.

  9. Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility

    PubMed Central

    Jafar, Maysam M; Parsai, Arman; Miquel, Marc E

    2016-01-01

    There is considerable disparity in the published apparent diffusion coefficient (ADC) values across different anatomies. Institutions are increasingly assessing repeatability and reproducibility of the derived ADC to determine its variation, which could potentially be used as an indicator in determining tumour aggressiveness or assessing tumour response. In this manuscript, a review of selected articles published to date in healthy extra-cranial body diffusion-weighted magnetic resonance imaging is presented, detailing reported ADC values and discussing their variation across different studies. In total 115 studies were selected including 28 for liver parenchyma, 15 for kidney (renal parenchyma), 14 for spleen, 13 for pancreatic body, 6 for gallbladder, 13 for prostate, 13 for uterus (endometrium, myometrium, cervix) and 13 for fibroglandular breast tissue. Median ADC values in selected studies were found to be 1.28 × 10-3 mm2/s in liver, 1.94 × 10-3 mm2/s in kidney, 1.60 × 10-3 mm2/s in pancreatic body, 0.85 × 10-3 mm2/s in spleen, 2.73 × 10-3 mm2/s in gallbladder, 1.64 × 10-3 mm2/s and 1.31 × 10-3 mm2/s in prostate peripheral zone and central gland respectively (combined median value of 1.54×10-3 mm2/s), 1.44 × 10-3 mm2/s in endometrium, 1.53 × 10-3 mm2/s in myometrium, 1.71 × 10-3 mm2/s in cervix and 1.92 × 10-3 mm2/s in breast. In addition, six phantom studies and thirteen in vivo studies were summarized to compare repeatability and reproducibility of the measured ADC. All selected phantom studies demonstrated lower intra-scanner and inter-scanner variation compared to in vivo studies. Based on the findings of this manuscript, it is recommended that protocols need to be optimised for the body part studied and that system-induced variability must be established using a standardized phantom in any clinical study. Reproducibility of the measured ADC must also be assessed in a volunteer population, as variations are far more significant in vivo compared with phantom studies. PMID:26834942

  10. Microbiologic tests in epidemiologic studies: are they reproducible?

    PubMed

    Aass, A M; Preus, H R; Zambon, J J; Gjermo, P

    1994-12-01

    Microbiologic assessments are often included in longitudinal studies to elucidate the significance of the association of certain Gram-negative bacteria and the development of periodontal diseases. In such studies, the reliability of methods is crucial. There are several methods to identify putative pathogens, and some of them are commercially available. The purpose of the present study was to compare the reproducibility of four different methods for detecting Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis, and Prevotella intermedia in order to evaluate their usefulness in epidemiologic studies. The test panel consisted of 10 young subjects and 10 adult periodontitis patients. Subgingival plaque was sampled from sites showing bone loss and "healthy" control sites. The four different methods for detecting the target bacteria were 1) cultivation, 2) Evalusite (a chair-side kit based on ELISA), 3) OmniGene, Inc, based on DNA probes, and 4) indirect immunofluorescence (IIF). The test procedure was repeated after a 1-wk interval and was performed by one examiner. Sites reported to be positive for a microorganism by any of the four methods at one or both examinations were considered to be positive for that organism and included in the analysis. The reproducibility of the four methods was low. The IIF and the cultivation methods showed somewhat higher reproducibility than did the commercial systems. A second test was done for Evalusite, three paper points for sampling being used instead of one as described in the manual. The reproducibility of the second test was improved, indicating that the detection level of the system may influence the reliability.

  11. Validation of the questionnaire on hand function assessment in leprosy.

    PubMed

    Ferreira, Telma Leonel; Alvarez, Rosicler Rocha Aiza; Virmond, Marcos da Cunha Lopes

    2012-06-01

    To validate the psychometric properties of the questionnaire on hand function assessment in leprosy. Study conducted with a convenience sample of 101 consecutive patients in Brasília (Central-Western Brazil), from June 2008 to July 2009. The individuals were adults affected by leprosy, with impairment of the ulnar, median and radial nerves. Interobservers and intraobserver reproducibility was analyzed through successive interviews, and construct validity was analyzed through association between age, clinical form of leprosy, duration of nerve injury, grip and pinch strength measured with a dynamometer, sensibility test performed with Semmes-Weinstein monofilaments and manual ability assessment using the Jebsen test of hand function. Pondered kappa coefficient was calculated and a Bland-Altman plot was constructed to assess the reproducibility of the instrument. For internal consistency, Cronbach's alpha coefficient was utilized. Pearson's correlation coefficient was calculated and a multiple regression model was used. The pondered kappa values for interobservers and intraobserver assessments ranged from 0.86 to 0.97 and from 0.85 to 0.97, respectively. The value of Cronbach's alpha coefficient was 0.967. Pearson's correlation coefficient showed an association (p < 0.001) among duration of nerve injury, grip and pinch strength, cutaneous sensibility and mean score in the Jebsen Test. The mean score of the questionnaire on hand functional assessment in leprosy was associated with operational classification of leprosy, duration of nerve injury, grip strength, cutaneous sensibility and manual ability (p < 0.0001 for the model as a whole). The questionnaire on hand functional assessment in leprosy presents almost perfect interobservers and intraobserver reproducibility, high internal consistency and correlation with operational classification of leprosy, duration of nerve injury, grip strength, cutaneous sensibility in the hands and manual ability.

  12. Development and validation of self-reported line drawings for assessment of knee malalignment and foot rotation: a cross-sectional comparative study

    PubMed Central

    2010-01-01

    Background For large scale epidemiological studies clinical assessments and radiographs can be impractical and expensive to apply to more than just a sample of the population examined. The study objectives were to develop and validate two novel instruments for self-reported knee malalignment and foot rotation suitable for use in questionnaire studies of knee pain and osteoarthritis. Methods Two sets of line drawings were developed using similar methodology. Each instrument consisted of an explanatory question followed by a set of drawings showing straight alignment, then two each at 7.5° angulation and 15° angulation in the varus/valgus (knee) and inward/outward (foot) directions. Forty one participants undertaking a community study completed the instruments on two occasions. Participants were assessed once by a blinded expert clinical observer with demonstrated excellent reproducibility. Validity was assessed by sensitivity, specificity and likelihood ratio (LR) using the observer as the reference standard. Reliability was assessed using weighted kappa (κ). Knee malalignment was measured on 400 knee radiographs. General linear model was used to assess for the presence of a linear increase in knee alignment angle (measured medially) from self-reported severe varus to mild varus, straight, mild valgus and severe valgus deformity. Results Observer reproducibility (κ) was 0.89 and 0.81 for the knee malalignment and foot rotation instruments respectively. Self-reported participant reproducibility was also good for the knee (κ 0.73) and foot (κ 0.87) instruments. Validity was excellent for the knee malalignment instrument, with a sensitivity of 0.74 (95%CI 0.54, 0.93) and specificity of 0.97 (95%CI 0.94, 1.00). Similarly the foot rotation instrument was also found to have high sensitivity (0.92, 95%CI 0.83, 1.01) and specificity (0.96, 95%CI 0.93, 1.00). The knee alignment angle increased progressively from self reported severe varus to mild varus, straight, mild valgus and severe valgus knee malalignment (ptrend <0.001). Conclusions The two novel instruments appear to provide a valid and reliable assessment of self-reported knee malalignment and foot rotation, and may have a practical use in epidemiological studies. PMID:20565825

  13. Reproducibility and validity of a semi-quantitative FFQ for trace elements.

    PubMed

    Lee, Yujin; Park, Kyong

    2016-09-01

    The aim of this study was to test the reproducibility and validity of a self-administered FFQ for the Trace Element Study of Korean Adults in the Yeungnam area (SELEN). Study subjects were recruited from the SELEN cohort selected from rural and urban areas in Yeungnam, Korea. A semi-quantitative FFQ with 146 items was developed considering the dietary characteristics of cohorts in the study area. In a validation study, seventeen men and forty-eight women aged 38-62 years completed 3-d dietary records (DR) and two FFQ over a 3-month period. The validity was examined with the FFQ and DR, and the reproducibility was estimated using partial correlation coefficients, the Bland-Altman method and cross-classification. There were no significant differences between the mean intakes of selected nutrients as estimated from FFQ1, FFQ2 and DR. The median correlation coefficients for all nutrients were 0·47 and 0·56 in the reproducibility and validity tests, respectively. Bland-Altman's index and cross-classification showed acceptable agreement between FFQ1 and FFQ2 and between FFQ2 and DR. Ultimately, 78 % of the subjects were classified into the same and adjacent quartiles for most nutrients. In addition, the weighted κ value indicated that the two methods agreed fairly. In conclusion, this newly developed FFQ was a suitable dietary assessment method for the SELEN cohort study.

  14. High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.

    PubMed

    Scott, Andrew D; Keegan, Jennifer; Firmin, David N

    2011-01-01

    To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P < 0.0001). Coronary wall thicknesses (± standard deviation [SD]) were not significantly different: 1.10 ± 0.14 mm (3D spiral (2RR)), 1.20 ± 0.16 mm (3D spiral (1RR)), 1.14 ± 0.15 mm (2D spiral), and 1.21 ± 0.17 mm (TSE). Wall thickness reproducibility ranged from good (ICC = 0.65, 3D spiral (1RR)) to excellent (ICC = 0.87, 3D spiral (2RR)). High-resolution 3D spiral imaging with B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression. Copyright © 2010 Wiley-Liss, Inc.

  15. A study of progress of labour using intrapartum translabial ultrasound, assessing head station, direction, and angle of descent.

    PubMed

    Tutschek, B; Braun, T; Chantraine, F; Henrich, W

    2011-01-01

    Intrapartum translabial ultrasound (ITU) has the potential to objectively and quantitatively assess the progress of labour. The relationships between the different ITU parameters and their development during normal term labour have not been studied. Observational study. University teaching hospital. Labouring women with normal term fetuses in cephalic presentation. Intrapartum translabial ultrasound measurements for 'head station', 'head direction', and 'angle of descent' (AoD) were taken in 50 labouring women, compared, studied for repeatability, and correlated with the progress of labour. Reproducibility and correlation of ITU parameters and their pattern of changes during labour. All three ITU parameters were clinically well reproducible. AoD and head station were interchangeable, and could be calculated from each other. Head station and head direction changed in a typical pattern along the birth canal. Time to delivery correlated with ITU head station. Intrapartum translabial ultrasound is a simple technique that improves the understanding of normal and abnormal labour, enables the objective measurement of birth progress and provides a more scientific basis for assessing labour. © 2010 The Authors Journal compilation © RCOG 2010 BJOG An International Journal of Obstetrics and Gynaecology.

  16. Assessment of Antero-Posterior Skeletal and Soft Tissue Relationships of Adult Indian Subjects in Natural Head Position and Centric Relation

    PubMed Central

    Latif, Vishnu Ben; Keshavaraj; Rai, Rohan; Hegde, Gautham; Shajahan, Shabna

    2015-01-01

    Background: The aim of this study was to verify the intra-individual reproducibility of natural head position (NHP) in centric relation (CR) position, to prove the inter-individual differences in the Frankfort horizontal plane and sella-nasion line compared with the true horizontal line, and to establish linear norms from A-point, B-point, Pog as well as soft tissue A-point, soft tissue B-point, and soft tissue Pog to nasion true vertical line (NTVL) in adult Indian subjects. Methods: Lateral cephalograms (T1) of Angle’s Class I subjects were taken in NHP and with bite in CR. A second lateral cephalogram (T2) of these subjects with ANB angle in the range 1-4° were taken after 1 week using the same wax bite and both the radiographs were analyzed based on six angular parameters using cephalometric software (Do-it, Dental studio NX version 4.1) to assess the reproducibility of NHP. Linear values of six landmarks were taken in relation to NTVL, and the mean values were calculated. A total of 116 subjects were included in this study. Results: When the cephalometric values of T1 and T2 were analyzed, it was found that, the parameters showed a P < 0.001, indicating the reproducibility of NHP in CR. Mean values for point A, point B, Pog and their soft tissue counterparts were also obtained. Conclusion: The study proved that NHP is a reproducible and accurate when recorded with the mandible in CR. Linear norms for skeletal Class I subjects in relation to NTVL were established. PMID:26124598

  17. Can we trust the calculation of texture indices of CT images? A phantom study.

    PubMed

    Caramella, Caroline; Allorant, Adrien; Orlhac, Fanny; Bidault, Francois; Asselain, Bernard; Ammari, Samy; Jaranowski, Patricia; Moussier, Aurelie; Balleyguier, Corinne; Lassau, Nathalie; Pitre-Champagnat, Stephanie

    2018-04-01

    Texture analysis is an emerging tool in the field of medical imaging analysis. However, many issues have been raised in terms of its use in assessing patient images and it is crucial to harmonize and standardize this new imaging measurement tool. This study was designed to evaluate the reliability of texture indices of CT images on a phantom including a reproducibility study, to assess the discriminatory capacity of indices potentially relevant in CT medical images and to determine their redundancy. For the reproducibility and discriminatory analysis, eight identical CT acquisitions were performed on a phantom including one homogeneous insert and two close heterogeneous inserts. Texture indices were selected for their high reproducibility and capability of discriminating different textures. For the redundancy analysis, 39 acquisitions of the same phantom were performed using varying acquisition parameters and a correlation matrix was used to explore the 2 × 2 relationships. LIFEx software was used to explore 34 different parameters including first order and texture indices. Only eight indices of 34 exhibited high reproducibility and discriminated textures from each other. Skewness and kurtosis from histogram were independent from the six other indices but were intercorrelated, the other six indices correlated in diverse degrees (entropy, dissimilarity, and contrast of the co-occurrence matrix, contrast of the Neighborhood Gray Level difference matrix, SZE, ZLNU of the Gray-Level Size Zone Matrix). Care should be taken when using texture analysis as a tool to characterize CT images because changes in quantitation may be primarily due to internal variability rather than from real physio-pathological effects. Some textural indices appear to be sufficiently reliable and capable to discriminate close textures on CT images. © 2018 American Association of Physicists in Medicine.

  18. METALS IN GROUND WATER: SAMPLING ARTIFACTS AND REPRODUCIBILITY

    EPA Science Inventory

    Field studies evaluated sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. esearch at three different metal-contaminated sites has shown that 0.45 tm filtration has not removed potentially mobile ...

  19. Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test.

    PubMed

    Hatanaka, Marcelo; Alencar, Luciana M; De Moraes, Carlos G; Susanna, Remo

    2013-01-01

    The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37). Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  20. Test–retest reliability and validity of a web-based food-frequency questionnaire for adolescents aged 13–14 to be used in the Norwegian Mother and Child Cohort Study (MoBa)

    PubMed Central

    Øverby, Nina Cecilie; Johannesen, Elisabeth; Jensen, Grete; Skjaevesland, Anne-Kirsti; Haugen, Margaretha

    2014-01-01

    Background The assessment of food intake is challenging and prone to errors; it is therefore important to consider the reliability and validity of the assessment methods. Objective The aim of this study was to analyze the reproducibility and validity of a developed food-frequency questionnaire (FFQ) for use among adolescents. Design In total, 58 students (aged 13–14) from four different schools in the southern part of Norway participated in the reproducibility study of filling out the FFQ 4 weeks apart. In addition, 93 students participated in the relative validity study where the FFQ was compared to 2×24-hour dietary recalls, while 92 students participated in the absolute validity study where the intakes of fatty acids and vitamin D from the FFQ were compared to fatty acids and 25-hydroxy-vitamin D3 in whole blood. Results The median Spearman correlation coefficient for all nutrients in the test–retest reliability study was 0.57. The median Spearman correlation for all nutrients in the relative validity study was 0.26, while the correlations coefficients were low in the absolute validity study with n-3 fatty acid coefficients ranging from 0.05 to 0.25, and absent for vitamin D (r=0.000). Conclusion The test–retest reproducibility was considered good, the relative validity was considered poor to good, and the absolute validity was considered poor. However, the results are comparable to other studies among adolescents. PMID:25371661

  1. The Jebsen Taylor Test of Hand Function: A Pilot Test-Retest Reliability Study in Typically Developing Children.

    PubMed

    Reedman, Sarah Elizabeth; Beagley, Simon; Sakzewski, Leanne; Boyd, Roslyn N

    2016-08-01

    The aim of this pilot study was to evaluate reproducibility of the Jebsen Taylor Test of Hand Function (JTTHF) in children. Eighty-seven typically developing children 5 to 10 years old were included from five Outside School Hours Care centers in the Greater Brisbane Region, Australia. Hand function was assessed on two occasions with a modified JTTHF, then reproducibility was assessed using Intraclass Correlation Coefficient (ICC [3,1]) and the Standard Error of Measurement (SEM). Total scores for male and female children were not significantly different. Five-year-old children were significantly different to all other age groups and were excluded from further analysis. Results for 71 children, 6 to 10 years old were analyzed (mean age 8.31 years (SD 1.32); 33 males). Test-retest reliability for total scores on the dominant and nondominant hands were ICC 0.74 (95% CI 0.61, 0.83) and ICC 0.72 (95% CI 0.59, 0.82), respectively. 'Writing' and 'Simulated Feeding' subtests demonstrated poor reproducibility. The Smallest Real Difference was 5.09 seconds for total score on the dominant hand. Findings indicate good test-retest reliability for the JTTHF total score to measure hand function in typically developing children aged 6 to 10 years.

  2. Reproducibility of repeated measurements with the Kikuhime pressure sensor under pressure garments in burn scar treatment.

    PubMed

    Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke

    2007-08-01

    This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.

  3. Assessment of Modeling Capability for Reproducing Storm Impacts on TEC

    NASA Astrophysics Data System (ADS)

    Shim, J. S.; Kuznetsova, M. M.; Rastaetter, L.; Bilitza, D.; Codrescu, M.; Coster, A. J.; Emery, B. A.; Foerster, M.; Foster, B.; Fuller-Rowell, T. J.; Huba, J. D.; Goncharenko, L. P.; Mannucci, A. J.; Namgaladze, A. A.; Pi, X.; Prokhorov, B. E.; Ridley, A. J.; Scherliess, L.; Schunk, R. W.; Sojka, J. J.; Zhu, L.

    2014-12-01

    During geomagnetic storm, the energy transfer from solar wind to magnetosphere-ionosphere system adversely affects the communication and navigation systems. Quantifying storm impacts on TEC (Total Electron Content) and assessment of modeling capability of reproducing storm impacts on TEC are of importance to specifying and forecasting space weather. In order to quantify storm impacts on TEC, we considered several parameters: TEC changes compared to quiet time (the day before storm), TEC difference between 24-hour intervals, and maximum increase/decrease during the storm. We investigated the spatial and temporal variations of the parameters during the 2006 AGU storm event (14-15 Dec. 2006) using ground-based GPS TEC measurements in the selected 5 degree eight longitude sectors. The latitudinal variations were also studied in two longitude sectors among the eight sectors where data coverage is relatively better. We obtained modeled TEC from various ionosphere/thermosphere (IT) models. The parameters from the models were compared with each other and with the observed values. We quantified performance of the models in reproducing the TEC variations during the storm using skill scores. This study has been supported by the Community Coordinated Modeling Center (CCMC) at the Goddard Space Flight Center. Model outputs and observational data used for the study will be permanently posted at the CCMC website (http://ccmc.gsfc.nasa.gov) for the space science communities to use.

  4. Systems-based biological concordance and predictive reproducibility of gene set discovery methods in cardiovascular disease.

    PubMed

    Azuaje, Francisco; Zheng, Huiru; Camargo, Anyela; Wang, Haiying

    2011-08-01

    The discovery of novel disease biomarkers is a crucial challenge for translational bioinformatics. Demonstration of both their classification power and reproducibility across independent datasets are essential requirements to assess their potential clinical relevance. Small datasets and multiplicity of putative biomarker sets may explain lack of predictive reproducibility. Studies based on pathway-driven discovery approaches have suggested that, despite such discrepancies, the resulting putative biomarkers tend to be implicated in common biological processes. Investigations of this problem have been mainly focused on datasets derived from cancer research. We investigated the predictive and functional concordance of five methods for discovering putative biomarkers in four independently-generated datasets from the cardiovascular disease domain. A diversity of biosignatures was identified by the different methods. However, we found strong biological process concordance between them, especially in the case of methods based on gene set analysis. With a few exceptions, we observed lack of classification reproducibility using independent datasets. Partial overlaps between our putative sets of biomarkers and the primary studies exist. Despite the observed limitations, pathway-driven or gene set analysis can predict potentially novel biomarkers and can jointly point to biomedically-relevant underlying molecular mechanisms. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    PubMed

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  6. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    PubMed Central

    Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz

    2017-01-01

    Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017

  7. Benchmarking contactless acquisition sensor reproducibility for latent fingerprint trace evidence

    NASA Astrophysics Data System (ADS)

    Hildebrandt, Mario; Dittmann, Jana

    2015-03-01

    Optical, nano-meter range, contactless, non-destructive sensor devices are promising acquisition techniques in crime scene trace forensics, e.g. for digitizing latent fingerprint traces. Before new approaches are introduced in crime investigations, innovations need to be positively tested and quality ensured. In this paper we investigate sensor reproducibility by studying different scans from four sensors: two chromatic white light sensors (CWL600/CWL1mm), one confocal laser scanning microscope, and one NIR/VIS/UV reflection spectrometer. Firstly, we perform an intra-sensor reproducibility testing for CWL600 with a privacy conform test set of artificial-sweat printed, computer generated fingerprints. We use 24 different fingerprint patterns as original samples (printing samples/templates) for printing with artificial sweat (physical trace samples) and their acquisition with contactless sensory resulting in 96 sensor images, called scan or acquired samples. The second test set for inter-sensor reproducibility assessment consists of the first three patterns from the first test set, acquired in two consecutive scans using each device. We suggest using a simple feature space set in spatial and frequency domain known from signal processing and test its suitability for six different classifiers classifying scan data into small differences (reproducible) and large differences (non-reproducible). Furthermore, we suggest comparing the classification results with biometric verification scores (calculated with NBIS, with threshold of 40) as biometric reproducibility score. The Bagging classifier is nearly for all cases the most reliable classifier in our experiments and the results are also confirmed with the biometric matching rates.

  8. A new framework to enhance the interpretation of external validation studies of clinical prediction models.

    PubMed

    Debray, Thomas P A; Vergouwe, Yvonne; Koffijberg, Hendrik; Nieboer, Daan; Steyerberg, Ewout W; Moons, Karel G M

    2015-03-01

    It is widely acknowledged that the performance of diagnostic and prognostic prediction models should be assessed in external validation studies with independent data from "different but related" samples as compared with that of the development sample. We developed a framework of methodological steps and statistical methods for analyzing and enhancing the interpretation of results from external validation studies of prediction models. We propose to quantify the degree of relatedness between development and validation samples on a scale ranging from reproducibility to transportability by evaluating their corresponding case-mix differences. We subsequently assess the models' performance in the validation sample and interpret the performance in view of the case-mix differences. Finally, we may adjust the model to the validation setting. We illustrate this three-step framework with a prediction model for diagnosing deep venous thrombosis using three validation samples with varying case mix. While one external validation sample merely assessed the model's reproducibility, two other samples rather assessed model transportability. The performance in all validation samples was adequate, and the model did not require extensive updating to correct for miscalibration or poor fit to the validation settings. The proposed framework enhances the interpretation of findings at external validation of prediction models. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Online Dietary Intake Estimation: Reproducibility and Validity of the Food4Me Food Frequency Questionnaire Against a 4-Day Weighed Food Record

    PubMed Central

    Fallaize, Rosalind; Forster, Hannah; Macready, Anna L; Walsh, Marianne C; Mathers, John C; Brennan, Lorraine; Gibney, Eileen R; Gibney, Michael J

    2014-01-01

    Background Advances in nutritional assessment are continuing to embrace developments in computer technology. The online Food4Me food frequency questionnaire (FFQ) was created as an electronic system for the collection of nutrient intake data. To ensure its accuracy in assessing both nutrient and food group intake, further validation against data obtained using a reliable, but independent, instrument and assessment of its reproducibility are required. Objective The aim was to assess the reproducibility and validity of the Food4Me FFQ against a 4-day weighed food record (WFR). Methods Reproducibility of the Food4Me FFQ was assessed using test-retest methodology by asking participants to complete the FFQ on 2 occasions 4 weeks apart. To assess the validity of the Food4Me FFQ against the 4-day WFR, half the participants were also asked to complete a 4-day WFR 1 week after the first administration of the Food4Me FFQ. Level of agreement between nutrient and food group intakes estimated by the repeated Food4Me FFQ and the Food4Me FFQ and 4-day WFR were evaluated using Bland-Altman methodology and classification into quartiles of daily intake. Crude unadjusted correlation coefficients were also calculated for nutrient and food group intakes. Results In total, 100 people participated in the assessment of reproducibility (mean age 32, SD 12 years), and 49 of these (mean age 27, SD 8 years) also took part in the assessment of validity. Crude unadjusted correlations for repeated Food4Me FFQ ranged from .65 (vitamin D) to .90 (alcohol). The mean cross-classification into “exact agreement plus adjacent” was 92% for both nutrient and food group intakes, and Bland-Altman plots showed good agreement for energy-adjusted macronutrient intakes. Agreement between the Food4Me FFQ and 4-day WFR varied, with crude unadjusted correlations ranging from .23 (vitamin D) to .65 (protein, % total energy) for nutrient intakes and .11 (soups, sauces and miscellaneous foods) to .73 (yogurts) for food group intake. The mean cross-classification into “exact agreement plus adjacent” was 80% and 78% for nutrient and food group intake, respectively. There were no significant differences between energy intakes estimated using the Food4Me FFQ and 4-day WFR, and Bland-Altman plots showed good agreement for both energy and energy-controlled nutrient intakes. Conclusions The results demonstrate that the online Food4Me FFQ is reproducible for assessing nutrient and food group intake and has moderate agreement with the 4-day WFR for assessing energy and energy-adjusted nutrient intakes. The Food4Me FFQ is a suitable online tool for assessing dietary intake in healthy adults. PMID:25113936

  10. An International Ki67 Reproducibility Study

    PubMed Central

    2013-01-01

    Background In breast cancer, immunohistochemical assessment of proliferation using the marker Ki67 has potential use in both research and clinical management. However, lack of consistency across laboratories has limited Ki67’s value. A working group was assembled to devise a strategy to harmonize Ki67 analysis and increase scoring concordance. Toward that goal, we conducted a Ki67 reproducibility study. Methods Eight laboratories received 100 breast cancer cases arranged into 1-mm core tissue microarrays—one set stained by the participating laboratory and one set stained by the central laboratory, both using antibody MIB-1. Each laboratory scored Ki67 as percentage of positively stained invasive tumor cells using its own method. Six laboratories repeated scoring of 50 locally stained cases on 3 different days. Sources of variation were analyzed using random effects models with log2-transformed measurements. Reproducibility was quantified by intraclass correlation coefficient (ICC), and the approximate two-sided 95% confidence intervals (CIs) for the true intraclass correlation coefficients in these experiments were provided. Results Intralaboratory reproducibility was high (ICC = 0.94; 95% CI = 0.93 to 0.97). Interlaboratory reproducibility was only moderate (central staining: ICC = 0.71, 95% CI = 0.47 to 0.78; local staining: ICC = 0.59, 95% CI = 0.37 to 0.68). Geometric mean of Ki67 values for each laboratory across the 100 cases ranged 7.1% to 23.9% with central staining and 6.1% to 30.1% with local staining. Factors contributing to interlaboratory discordance included tumor region selection, counting method, and subjective assessment of staining positivity. Formal counting methods gave more consistent results than visual estimation. Conclusions Substantial variability in Ki67 scoring was observed among some of the world’s most experienced laboratories. Ki67 values and cutoffs for clinical decision-making cannot be transferred between laboratories without standardizing scoring methodology because analytical validity is limited. PMID:24203987

  11. Three-dimensional endoanal ultrasound is accurate and reproducible in determining type and height of anal fistulas.

    PubMed

    Kołodziejczak, M; Santoro, G A; Obcowska, A; Lorenc, Z; Mańczak, M; Sudoł-Szopińska, I

    2017-04-01

    Surgical treatment of high anal fistulas is associated with the potential risk of faecal incontinence and recurrence. The primary aim of this study was to determine the accuracy of three-dimensional endoanal ultrasound (3D-EAUS) in the assessment of height and type of anal fistulas, compared to the intra-operative findings (gold standard). The secondary aim was to evaluate the inter-observer reproducibility of 3D-EAUS. The study design was a prospective analysis of retrospective data. 299 patients (202 men), mean age 45.3 years, who underwent surgery for anal fistulas, were included. All patients were preoperatively assessed by 3D-EAUS. Two readers independently reviewed the volumes to determine the type and height of fistulas. Sensitivity, specificity, positive and negative predictive values, proportion of agreements and Cohen's kappa coefficient (κ) were calculated for both examiners. Ultrasound findings were compared with intra-operative data (reference standard), evaluated blindly by the surgeons. At surgery, 201 (67%) were transsphincteric, 49 (16%) suprasphincteric, 47 (16%) intersphincteric and two (1%) extrasphincteric fistulas. Intra-operatively, 177 (59%) were low and 122 (41%) high fistulas. The overall accuracy of 3D-EAUS was 91% for fistula type (271/299 fistulas: 97% transsphincteric, 100% intersphincteric, 57% suprasphincteric, 0% extrasphincteric) and 92% for fistula height (275/299 fistulas: 80% high and 100% low). Both readers reported very good agreement with surgery in the assessment of fistula type (proportion of agreement 0.88, κ = 0.89) and height (proportion of agreement 0.90, κ = 0.91). 3D-EAUS is an accurate and reproducible modality for the assessment of type and height of anal fistulas. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  12. A Diet Score Assessing Norwegian Adolescents' Adherence to Dietary Recommendations-Development and Test-Retest Reproducibility of the Score.

    PubMed

    Handeland, Katina; Kjellevold, Marian; Wik Markhus, Maria; Eide Graff, Ingvild; Frøyland, Livar; Lie, Øyvind; Skotheim, Siv; Stormark, Kjell Morten; Dahl, Lisbeth; Øyen, Jannike

    2016-07-29

    Assessment of adolescents' dietary habits is challenging. Reliable instruments to monitor dietary trends are required to promote healthier behaviours in this group. The purpose of this cross-sectional study was to assess adolescents' adherence to Norwegian dietary recommendations with a diet score and to report results from, and test-retest reliability of, the score. The diet score involved seven food groups and one physical activity indicator, and was applied to answers from a semi-quantitative food frequency questionnaire (FFQ) administered twice. Reproducibility of the score was assessed with Cohen's Kappa (κ statistics) at an interval of three months. The setting was eight lower-secondary schools in Hordaland County, Norway, and subjects were adolescents (n = 472) aged 14-15 years and their caregivers. Results showed that the proportion of adolescents consistently classified by the diet score was 87.6% (κ = 0.465). For food groups, proportions ranged from 74.0% to 91.6% (κ = 0.249 to κ = 0.573). Less than 40% of the participants were found to adhere to recommendations for frequencies of eating fruits, vegetables, added sugar, and fish. Highest compliance to recommendations was seen for choosing water as beverage and limit the intake of red meat. The score was associated with parental socioeconomic status. The diet score was found to be reproducible at an acceptable level. Health promoting work targeting adolescents should emphasize to increase the intake of recommended foods to approach nutritional guidelines.

  13. A Diet Score Assessing Norwegian Adolescents’ Adherence to Dietary Recommendations—Development and Test-Retest Reproducibility of the Score

    PubMed Central

    Handeland, Katina; Kjellevold, Marian; Wik Markhus, Maria; Eide Graff, Ingvild; Frøyland, Livar; Lie, Øyvind; Skotheim, Siv; Stormark, Kjell Morten; Dahl, Lisbeth; Øyen, Jannike

    2016-01-01

    Assessment of adolescents’ dietary habits is challenging. Reliable instruments to monitor dietary trends are required to promote healthier behaviours in this group. The purpose of this cross-sectional study was to assess adolescents’ adherence to Norwegian dietary recommendations with a diet score and to report results from, and test-retest reliability of, the score. The diet score involved seven food groups and one physical activity indicator, and was applied to answers from a semi-quantitative food frequency questionnaire (FFQ) administered twice. Reproducibility of the score was assessed with Cohen’s Kappa (κ statistics) at an interval of three months. The setting was eight lower-secondary schools in Hordaland County, Norway, and subjects were adolescents (n = 472) aged 14–15 years and their caregivers. Results showed that the proportion of adolescents consistently classified by the diet score was 87.6% (κ = 0.465). For food groups, proportions ranged from 74.0% to 91.6% (κ = 0.249 to κ = 0.573). Less than 40% of the participants were found to adhere to recommendations for frequencies of eating fruits, vegetables, added sugar, and fish. Highest compliance to recommendations was seen for choosing water as beverage and limit the intake of red meat. The score was associated with parental socioeconomic status. The diet score was found to be reproducible at an acceptable level. Health promoting work targeting adolescents should emphasize to increase the intake of recommended foods to approach nutritional guidelines. PMID:27483312

  14. Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects

    PubMed Central

    Polska, E; Polak, K; Luksch, A; Fuchsjager-Mayrl, G; Petternel, V; Findl, O; Schmetterer, L

    2004-01-01

    Aims/background: To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. Methods: The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. Results: None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. Conclusions: These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency. PMID:15031172

  15. Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.

    PubMed

    Polska, E; Polak, K; Luksch, A; Fuchsjager-Mayrl, G; Petternel, V; Findl, O; Schmetterer, L

    2004-04-01

    To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency.

  16. Coronary flow velocity reserve by echocardiography: feasibility, reproducibility and agreement with PET in overweight and obese patients with stable and revascularized coronary artery disease.

    PubMed

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin; Christensen, Thomas Emil; Ghotbi, Adam Ali; Hasbak, Philip; Kjaer, Andreas; Haugaard, Steen B; Prescott, Eva

    2016-06-07

    Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow reserve (MFR) measured by PET in overweight and obese patients. Participants with revascularized coronary artery disease were examined by CFVR. Subgroups were examined by repeated CFVR (reproducibility) or Rubidium-82-PET (agreement). To account for time variation, results were computed for scans performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5 %, and reliability 0.97. Agreement with MFR of the LAD territory (n = 35) was without significant bias and overall LOA were (-1.40;1.46). Agreement was best for examinations performed within 1-week of participants without MI of the LAD-territory (n = 12); LOA = (-0.68;0.88). CFVR was highly feasible with a good reproducibility on par with other contemporary measures applied in cardiology. Agreement with MFR was acceptable, though discrepancy related to prior MI has to be considered. CFVR of LAD is a valid tool in overweight and obese patients.

  17. Reproducibility of forearm vasodilator response to intra-arterial infusion of calcitonin gene-related peptide assessed by venous occlusion plethysmography

    PubMed Central

    Vanmolkot, Floris H M; de Hoon, Jan N J M

    2005-01-01

    Aims To assess the reproducibility of the forearm blood flow (FBF) response to intra-arterial infusion of calcitonin-gene related peptide (CGRP), measured by venous occlusion plethysmography. In addition, to compare different ways of expressing the FBF response and perform sample size calculations. Methods On two separate visits, CGRP (10 ng min−1 dl−1 forearm) was infused for 45 min into the brachial artery of six healthy subjects. Reproducibility was assessed by calculating mean difference, repeatability coefficient, within-subject coefficient of variation (WCV) and intraclass correlation coefficient. Results CGRP increased FBF from 2.8 ± 0.4 and 3.2 ± 0.7 (at baseline) to 15.4 ± 1.4 and 15.2 ± 1.5 ml min−1 dl−1 forearm (at 45 min) on visits 1 and 2, respectively (P < 0.0001 for both visits). Mean difference in FBF at 45 min between both visits was 0.3 ml min−1 dl−1 forearm (repeatability coefficient: 4.1 ml min−1 dl−1 forearm). This FBF response appeared to be more reproducible when expressed as absolute FBF in the infused arm (WCV 11%) compared with absolute FBF-ratio between both arms (WCV 37%), percentage change from baseline in FBF in the infused arm (WCV 29%) and percentage change from baseline in FBF-ratio (WCV 40%). When expressed as absolute FBF, a sample size of five (95% confidence interval: 2–12) subjects gives 90% power at a type I error probability of 0.05 to detect a 25% shift in FBF response. Conclusions Intra-arterial infusion of CGRP results in a forearm vasodilator response which is reproducible between days. This response is most reproducible when expressed as absolute FBF. The presented methodology provides a suitable pharmacodynamic model to assess the in vivo activity of CGRP-receptor antagonists in a small number of subjects. PMID:15801933

  18. FRAMES-2.0 Software System: Providing Password Protection and Limited Access to Models and Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whelan, Gene; Pelton, Mitch A.

    2007-08-09

    One of the most important concerns for regulatory agencies is the concept of reproducibility (i.e., reproducibility means credibility) of an assessment. One aspect of reproducibility deals with tampering of the assessment. In other words, when multiple groups are engaged in an assessment, it is important to lock down the problem that is to be solved and/or to restrict the models that are to be used to solve the problem. The objective of this effort is to provide the U.S. Nuclear Regulatory Commission (NRC) with a means to limit user access to models and to provide a mechanism to constrain themore » conceptual site models (CSMs) when appropriate. The purpose is to provide the user (i.e., NRC) with the ability to “lock down” the CSM (i.e., picture containing linked icons), restrict access to certain models, or both.« less

  19. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    PubMed

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86

  20. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  1. CT Guidance is Needed to Achieve Reproducible Positioning of the Mouse Head for Repeat Precision Cranial Irradiation

    PubMed Central

    Armour, M.; Ford, E.; Iordachita, I.; Wong, J.

    2011-01-01

    To study the effects of cranial irradiation, we have constructed an all-plastic mouse bed equipped with an immobilizing head holder. The bed integrates with our in-house Small Animal Radiation Research Platform (SARRP) for precision focal irradiation experiments and cone-beam CT. We assessed the reproducibility of our head holder to determine the need for CT based targeting in cranial irradiation studies. To measure the holder’s reproducibility, a C57BL/6 mouse was positioned and CT scanned nine times. Image sets were loaded into the Pinnacle3 radiation treatment planning system and were registered to one another by one investigator using rigid body alignment of the cranial regions. Rotational and translational offsets were measured. The average vector shift between scans was 0.80 ± 0.49 mm. Such a shift is too large to selectively treat subregions of the mouse brain. In response, we use onboard imaging to guide cranial irradiation applications that require sub-millimeter precision. PMID:20041766

  2. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    PubMed

    Walker, Christopher M; Lee, Jaehyuk; Ramirez, Marc S; Schellingerhout, Dawid; Millward, Steven; Bankson, James A

    2013-01-01

    In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  3. CT guidance is needed to achieve reproducible positioning of the mouse head for repeat precision cranial irradiation.

    PubMed

    Armour, M; Ford, E; Iordachita, I; Wong, J

    2010-01-01

    To study the effects of cranial irradiation, we have constructed an all-plastic mouse bed equipped with an immobilizing head holder. The bed integrates with our in-house Small Animal Radiation Research Platform (SARRP) for precision focal irradiation experiments and cone-beam CT. We assessed the reproducibility of our head holder to determine the need for CT-based targeting in cranial irradiation studies. To measure the holder's reproducibility, a C57BL/6 mouse was positioned and CT-scanned nine times. Image sets were loaded into the Pinnacle(3) radiation treatment planning system and were registered to one another by one investigator using rigid body alignment of the cranial regions. Rotational and translational offsets were measured. The average vector shift between scans was 0.80 +/- 0.49 mm. Such a shift is too large to selectively treat subregions of the mouse brain. In response, we use onboard imaging to guide cranial irradiation applications that require sub-millimeter precision.

  4. Letter regarding 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics' by Patrizi et al. and research reproducibility.

    PubMed

    2017-04-01

    The reporting of research in a manner that allows reproduction in subsequent investigations is important for scientific progress. Several details of the recent study by Patrizi et al., 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics', are absent from the published manuscript and make reproduction of findings impossible. As new and complex technologies with great promise for ergonomics develop, new but surmountable challenges for reporting investigations using these technologies in a reproducible manner arise. Practitioner Summary: As with traditional methods, scientific reporting of new and complex ergonomics technologies should be performed in a manner that allows reproduction in subsequent investigations and supports scientific advancement.

  5. Reproducibility of Dual-Microphone Voice Range Profile Equipment

    ERIC Educational Resources Information Center

    Printz, Trine; Pedersen, Ellen Raben; Juhl, Peter; Nielsen, Troels; Grøntved, Ågot Møller; Godballe, Christian

    2017-01-01

    Purpose: The aim of this study was to add further knowledge about the usefulness of the Voice Range Profile (VRP) assessment in clinical settings and research by analyzing VRP dual-microphone equipment precision, reliability, and room effect. Method: Test-retest studies were conducted in an anechoic chamber and an office: (a) comparing sound…

  6. Magnetic resonance imaging of articular cartilage: trauma, degeneration, and repair.

    PubMed

    Potter, Hollis G; Foo, Li F

    2006-04-01

    The assessment of articular cartilage using magnetic resonance imaging has seen considerable advances in recent years. Cartilage morphologic characteristics can now be evaluated with a high degree of accuracy and reproducibility using dedicated pulse sequences, which are becoming standard at many institutions. These techniques detect clinically unsuspected traumatic cartilage lesions, allowing the physician to study their natural history with longitudinal evaluation and also to assess disease status in degenerative osteoarthritis. Magnetic resonance imaging also provides a more objective assessment of cartilage repair to augment the information obtained from more subjective clinical outcome instruments. Newly developed methods that provide detail at an ultrastructural level offer an important addition to cartilage evaluation, particularly in the detection of early alterations in the extracellular matrix. These methods have created an undeniably important role for magnetic resonance imaging in the reproducible, noninvasive, and objective evaluation and monitoring of cartilage. An overview of the advances, current techniques, and impact of magnetic resonance imaging in the setting of trauma, degenerative arthritides, and surgical treatment for cartilage injury is presented.

  7. Qualitative radiology assessment of tumor response: does it measure up?

    PubMed

    Gottlieb, Ronald H; Litwin, Alan; Gupta, Bhavna; Taylor, John; Raczyk, Cheryl; Mashtare, Terry; Wilding, Gregory; Fakih, Marwan

    2008-01-01

    Our purpose was to assess whether a simpler qualitative evaluation of tumor response by computed tomography is as reproducible and predictive of clinical outcome as the Response Evaluation Criteria in Solid Tumors (RECIST) and World Health Organization (WHO) methods. This study was a two-reader retrospective evaluation in which qualitative assessment resulted in agreement in 21 of 23 patients with metastatic colorectal carcinoma (91.3%, kappa=0.78; 95% CI, 0.51-1.00). Hepatic metastases were classified as increased, decreased, or unchanged, compared with agreement in 20 of 23 patients (87.0%) for RECIST (kappa=0.62; 95% CI, 0.23-1.00) and WHO (kappa=0.67; 95% CI, 0.34-1.00) methods. Patients were placed into partial response, stable disease, and disease progression categories. Time to progression of disease was better predicted qualitatively than by RECIST or WHO. Our pilot data suggest that our qualitative scoring system is more reproducible and predictive of patient clinical outcome than the RECIST and WHO methods.

  8. Evaluating Structural Equation Models for Categorical Outcomes: A New Test Statistic and a Practical Challenge of Interpretation.

    PubMed

    Monroe, Scott; Cai, Li

    2015-01-01

    This research is concerned with two topics in assessing model fit for categorical data analysis. The first topic involves the application of a limited-information overall test, introduced in the item response theory literature, to structural equation modeling (SEM) of categorical outcome variables. Most popular SEM test statistics assess how well the model reproduces estimated polychoric correlations. In contrast, limited-information test statistics assess how well the underlying categorical data are reproduced. Here, the recently introduced C2 statistic of Cai and Monroe (2014) is applied. The second topic concerns how the root mean square error of approximation (RMSEA) fit index can be affected by the number of categories in the outcome variable. This relationship creates challenges for interpreting RMSEA. While the two topics initially appear unrelated, they may conveniently be studied in tandem since RMSEA is based on an overall test statistic, such as C2. The results are illustrated with an empirical application to data from a large-scale educational survey.

  9. Threshold level for measurement of UV sensitivity: reproducibility of phototest.

    PubMed

    Lock-Andersen, J; Wulf, H C

    1996-08-01

    The ultraviolet (UV) sensitivity is determined by a phototest where the skin is exposed to well-defined doses of UV radiation and the resulting erythema is graded by visual scoring after 20-24 h. In this study we wanted to estimate the reproducibility of erythema assessment in phototesting. Twenty-one healthy Caucasians with skin types I to IV were phototested on UV un-exposed buttock skin using a xenon lamp solar simulator. Twenty-four hours after UV exposure eight physicians independently graded the erythema reactions two times. Data were analysed using inter- and intra-observer agreement and kappa statistics, which adjusts for agreement that could be caused by chance alone. Observed agreement and kappa statistics were found to decrease with increasing intensity of erythema and to be lower for skin types III and IV compared to skin types I and II. Intra-observer agreement was uniformly better than inter-observer agreement. The difference between observers assessment could be as much as three clinical erythema grades. Physicians's previous experience with phototesting only had a minor influence on agreement. In conclusion, phototesting is based on subjective assessment of erythema and is not as precise and reproducible as expected. Agreement was better for barely perceptible erythema than for erythema with a well-defined border and we therefore recommend that the barely perceptible erythema reaction should be used for measurement of the minimal erythema dose.

  10. Interactive Sonification Exploring Emergent Behavior Applying Models for Biological Information and Listening

    PubMed Central

    Choi, Insook

    2018-01-01

    Sonification is an open-ended design task to construct sound informing a listener of data. Understanding application context is critical for shaping design requirements for data translation into sound. Sonification requires methodology to maintain reproducibility when data sources exhibit non-linear properties of self-organization and emergent behavior. This research formalizes interactive sonification in an extensible model to support reproducibility when data exhibits emergent behavior. In the absence of sonification theory, extensibility demonstrates relevant methods across case studies. The interactive sonification framework foregrounds three factors: reproducible system implementation for generating sonification; interactive mechanisms enhancing a listener's multisensory observations; and reproducible data from models that characterize emergent behavior. Supramodal attention research suggests interactive exploration with auditory feedback can generate context for recognizing irregular patterns and transient dynamics. The sonification framework provides circular causality as a signal pathway for modeling a listener interacting with emergent behavior. The extensible sonification model adopts a data acquisition pathway to formalize functional symmetry across three subsystems: Experimental Data Source, Sound Generation, and Guided Exploration. To differentiate time criticality and dimensionality of emerging dynamics, tuning functions are applied between subsystems to maintain scale and symmetry of concurrent processes and temporal dynamics. Tuning functions accommodate sonification design strategies that yield order parameter values to render emerging patterns discoverable as well as rehearsable, to reproduce desired instances for clinical listeners. Case studies are implemented with two computational models, Chua's circuit and Swarm Chemistry social agent simulation, generating data in real-time that exhibits emergent behavior. Heuristic Listening is introduced as an informal model of a listener's clinical attention to data sonification through multisensory interaction in a context of structured inquiry. Three methods are introduced to assess the proposed sonification framework: Listening Scenario classification, data flow Attunement, and Sonification Design Patterns to classify sound control. Case study implementations are assessed against these methods comparing levels of abstraction between experimental data and sound generation. Outcomes demonstrate the framework performance as a reference model for representing experimental implementations, also for identifying common sonification structures having different experimental implementations, identifying common functions implemented in different subsystems, and comparing impact of affordances across multiple implementations of listening scenarios. PMID:29755311

  11. Differential reflectometry versus tactile sense detection of subgingival calculus in dentistry

    NASA Astrophysics Data System (ADS)

    Shakibaie, Fardad; Walsh, Laurence J.

    2012-10-01

    Detecting dental calculus is clinically challenging in dentistry. This study used typodonts with extracted premolar and molar teeth and simulated gingival tissue to compare the performance of differential reflectometry and periodontal probing. A total of 30 extracted teeth were set in an anatomical configuration in stone to create three typodonts. Clear polyvinyl siloxane impression material was placed to replicate the periodontal soft tissues. Pocket depths ranged from 10 to 15 mm. The three models were placed in a phantom head, and an experienced dentist assessed the presence of subgingival calculus first using the DetecTar (differential reflectometry) and then a periodontal probe. Scores from these two different methods were compared to the gold standard (direct examination of the root surface using 20× magnification) to determine the accuracy and reproducibility. Differential reflectometry was more accurate than tactile assessment (79% versus 60%), and its reproducibility was also higher (Cohen kappa 0.54 versus 0.39). Both methods performed better on single rooted premolar teeth than on multirooted teeth. These laboratory results indicate that differential reflectometry allows more accurate and reproducible detection of subgingival calculus than conventional probing, and supports its use for supplementing traditional periodontal examination methods in dental practice.

  12. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    PubMed

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  13. Accelerating Biomedical Discoveries through Rigor and Transparency.

    PubMed

    Hewitt, Judith A; Brown, Liliana L; Murphy, Stephanie J; Grieder, Franziska; Silberberg, Shai D

    2017-07-01

    Difficulties in reproducing published research findings have garnered a lot of press in recent years. As a funder of biomedical research, the National Institutes of Health (NIH) has taken measures to address underlying causes of low reproducibility. Extensive deliberations resulted in a policy, released in 2015, to enhance reproducibility through rigor and transparency. We briefly explain what led to the policy, describe its elements, provide examples and resources for the biomedical research community, and discuss the potential impact of the policy on translatability with a focus on research using animal models. Importantly, while increased attention to rigor and transparency may lead to an increase in the number of laboratory animals used in the near term, it will lead to more efficient and productive use of such resources in the long run. The translational value of animal studies will be improved through more rigorous assessment of experimental variables and data, leading to better assessments of the translational potential of animal models, for the benefit of the research community and society. Published by Oxford University Press on behalf of the Institute for Laboratory Animal Research 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  14. Development of a stable and sensitive semiconductor detector by using a mixture of lead(II) iodide and lead monoxide for NDT radiation dose detection

    NASA Astrophysics Data System (ADS)

    Heo, Y. J.; Kim, K. T.; Han, M. J.; Moon, C. W.; Kim, J. E.; Park, J. K.; Park, S. K.

    2018-03-01

    Recently, high-energy radiation has been widely used in various industrial fields, including the medical industry, and increasing research efforts have been devoted to the development of radiation detectors to be used with high-energy radiation. In particular, nondestructive industrial applications use high-energy radiation for ships and multilayered objects for accurate inspection. Therefore, it is crucial to verify the accuracy of radiation dose measurements and evaluate the precision and reproducibility of the radiation output dose. Representative detectors currently used for detecting the dose in high-energy regions include Si diodes, diamond diodes, and ionization chambers. However, the process of preparing these detectors is complex in addition to the processes of conducting dosimetric measurements, analysis, and evaluation. Furthermore, the minimum size that can be prepared for a detector is limited. In the present study, the disadvantages of original detectors are compensated by the development of a detector made of a mixture of polycrystalline PbI2 and PbO powder, which are both excellent semiconducting materials suitable for detecting high-energy gamma rays and X-rays. The proposed detector shows characteristics of excellent reproducibility and stable signal detection in response to the changes in energy, and was analyzed for its applicability. Moreover, the detector was prepared through a simple process of particle-in-binder to gain control over the thickness and meet the specific value designated by the user. A mixture mass ratio with the highest reproducibility was determined through reproducibility testing with respect to changes in the photon energy. The proposed detector was evaluated for its detection response characteristics with respect to high-energy photon beam, in terms of dose-rate dependence, sensitivity, and linearity evaluation. In the reproducibility assessment, the detector made with 15 wt% PbO powder showed the best characteristics of 0.59% and 0.25% at 6 and 15 MV, respectively. Based on its selection in the reproducibility assessment, the 15 wt% PbO detector showed no dependence on the dose-rate changes, with R-SD < 1%. Finally, a coefficient of determination of 1 in the linearity assessment demonstrated very good linearity with regards to changes in dose. These results demonstrate the applicability and usefulness of the proposed detector made from a mixture of PbI2 and PbO semiconductors.

  15. Intra-observer reproducibility and diagnostic performance of breast shear-wave elastography in Asian women.

    PubMed

    Park, Hye Young; Han, Kyung Hwa; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-06-01

    Our aim was to evaluate intra-observer reproducibility of shear-wave elastography (SWE) in Asian women. Sixty-four breast masses (24 malignant, 40 benign) were examined with SWE in 53 consecutive Asian women (mean age, 44.9 y old). Two SWE images were obtained for each of the lesions. The intra-observer reproducibility was assessed by intra-class correlation coefficients (ICC). We also evaluated various clinicoradiologic factors that can influence reproducibility in SWE. The ICC of intra-observer reproducibility was 0.789. In clinicoradiologic factor evaluation, masses surrounded by mixed fatty and glandular tissue (ICC: 0.619) showed lower intra-observer reproducibility compared with lesions that were surrounded by glandular tissue alone (ICC: 0.937; p < 0.05). Overall, the intra-observer reproducibility of breast SWE was excellent in Asian women. However, it may decrease when breast tissue is in a heterogeneous background. Therefore, SWE should be performed carefully in these cases. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. A systematic assessment of normalization approaches for the Infinium 450K methylation platform.

    PubMed

    Wu, Michael C; Joubert, Bonnie R; Kuan, Pei-fen; Håberg, Siri E; Nystad, Wenche; Peddada, Shyamal D; London, Stephanie J

    2014-02-01

    The Illumina Infinium HumanMethylation450 BeadChip has emerged as one of the most popular platforms for genome wide profiling of DNA methylation. While the technology is wide-spread, systematic technical biases are believed to be present in the data. For example, this array incorporates two different chemical assays, i.e., Type I and Type II probes, which exhibit different technical characteristics and potentially complicate the computational and statistical analysis. Several normalization methods have been introduced recently to adjust for possible biases. However, there is considerable debate within the field on which normalization procedure should be used and indeed whether normalization is even necessary. Yet despite the importance of the question, there has been little comprehensive comparison of normalization methods. We sought to systematically compare several popular normalization approaches using the Norwegian Mother and Child Cohort Study (MoBa) methylation data set and the technical replicates analyzed with it as a case study. We assessed both the reproducibility between technical replicates following normalization and the effect of normalization on association analysis. Results indicate that the raw data are already highly reproducible, some normalization approaches can slightly improve reproducibility, but other normalization approaches may introduce more variability into the data. Results also suggest that differences in association analysis after applying different normalizations are not large when the signal is strong, but when the signal is more modest, different normalizations can yield very different numbers of findings that meet a weaker statistical significance threshold. Overall, our work provides useful, objective assessment of the effectiveness of key normalization methods.

  17. Current whole-body MRI applications in the neurofibromatoses

    PubMed Central

    Fayad, Laura M.; Khan, Muhammad Shayan; Bredella, Miriam A.; Harris, Gordon J.; Evans, D. Gareth; Farschtschi, Said; Jacobs, Michael A.; Chhabra, Avneesh; Salamon, Johannes M.; Wenzel, Ralph; Mautner, Victor F.; Dombi, Eva; Cai, Wenli; Plotkin, Scott R.; Blakeley, Jaishri O.

    2016-01-01

    Objectives: The Response Evaluation in Neurofibromatosis and Schwannomatosis (REiNS) International Collaboration Whole-Body MRI (WB-MRI) Working Group reviewed the existing literature on WB-MRI, an emerging technology for assessing disease in patients with neurofibromatosis type 1 (NF1), neurofibromatosis type 2 (NF2), and schwannomatosis (SWN), to recommend optimal image acquisition and analysis methods to enable WB-MRI as an endpoint in NF clinical trials. Methods: A systematic process was used to review all published data about WB-MRI in NF syndromes to assess diagnostic accuracy, feasibility and reproducibility, and data about specific techniques for assessment of tumor burden, characterization of neoplasms, and response to therapy. Results: WB-MRI at 1.5T or 3.0T is feasible for image acquisition. Short tau inversion recovery (STIR) sequence is used in all investigations to date, suggesting consensus about the utility of this sequence for detection of WB tumor burden in people with NF. There are insufficient data to support a consensus statement about the optimal imaging planes (axial vs coronal) or 2D vs 3D approaches. Functional imaging, although used in some NF studies, has not been systematically applied or evaluated. There are no comparative studies between regional vs WB-MRI or evaluations of WB-MRI reproducibility. Conclusions: WB-MRI is feasible for identifying tumors using both 1.5T and 3.0T systems. The STIR sequence is a core sequence. Additional investigation is needed to define the optimal approach for volumetric analysis, the reproducibility of WB-MRI in NF, and the diagnostic performance of WB-MRI vs regional MRI. PMID:27527647

  18. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  19. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    PubMed Central

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  20. Reproducibility of Retinal Microvascular Traits Decoded by the Singapore I Vessel Assessment Software Across the Human Age Range.

    PubMed

    Huang, Qi-Fang; Wei, Fang-Fei; Zhang, Zhen-Yu; Raaijmakers, Anke; Asayama, Kei; Thijs, Lutgarde; Yang, Wen-Yi; Mujaj, Blerim; Allegaert, Karel; Verhamme, Peter; Struijker-Boudier, Harry A J; Li, Yan; Staessen, Jan A

    2018-03-10

    Retinal microvascular traits predict adverse health outcomes. The Singapore I Vessel Assessment (SIVA) software improved automated postprocessing of retinal photographs. In addition to microvessel caliber, it generates measures of arteriolar and venular geometry. Few studies addressed the reproducibility of SIVA measurements across a wide age range. In the current study, 2 blinded graders read images obtained by nonmydriatic retinal photography twice in 20 11-year-old children, born prematurely (n = 10) or at term (n = 10) and in 60 adults (age range, 18.9-86.1 years). Former preterm compared with term children had lower microvessel diameter and disorganized vessel geometry with no differences in intraobserver and interobserver variability. Among adults, microvessel caliber decreased with age and blood pressure and arteriolar geometry was inversely correlated with female sex and age. Intraobserver differences estimated by the Bland-Altman method did not reach significance for any measurement. Across measurements, median reproducibility (RM) expressed as percent of the average trait value was 8.8% in children (median intraclass correlation coefficient [ICC], 0.94) and 8.0% (0.97) in adults. Likewise, interobserver differences did not reach significance with RM (ICC) of 10.6% (0.85) in children and 10.4% (0.93) in adults. Reproducibility was best for microvessel caliber (intraobserver/interobserver RM, 4.7%/6.0%; ICC, 0.98/0.96), worst for venular geometry (17.0%/18.8%; 0.93/0.84), and intermediate for arteriolar geometry (10.9%/14.9%; 0.95/0.86). SIVA produces repeatable measures of the retinal microvasculature in former preterm and term children and in adults, thereby proving its usability from childhood to old age.

  1. Reproducibility of Brain Morphometry from Short-Term Repeat Clinical MRI Examinations: A Retrospective Study

    PubMed Central

    Liu, Hon-Man; Chen, Shan-Kai; Chen, Ya-Fang; Lee, Chung-Wei; Yeh, Lee-Ren

    2016-01-01

    Purpose To assess the inter session reproducibility of automatic segmented MRI-derived measures by FreeSurfer in a group of subjects with normal-appearing MR images. Materials and Methods After retrospectively reviewing a brain MRI database from our institute consisting of 14,758 adults, those subjects who had repeat scans and had no history of neurodegenerative disorders were selected for morphometry analysis using FreeSurfer. A total of 34 subjects were grouped by MRI scanner model. After automatic segmentation using FreeSurfer, label-wise comparison (involving area, thickness, and volume) was performed on all segmented results. An intraclass correlation coefficient was used to estimate the agreement between sessions. Wilcoxon signed rank test was used to assess the population mean rank differences across sessions. Mean-difference analysis was used to evaluate the difference intervals across scanners. Absolute percent difference was used to estimate the reproducibility errors across the MRI models. Kruskal-Wallis test was used to determine the across-scanner effect. Results The agreement in segmentation results for area, volume, and thickness measurements of all segmented anatomical labels was generally higher in Signa Excite and Verio models when compared with Sonata and TrioTim models. There were significant rank differences found across sessions in some labels of different measures. Smaller difference intervals in global volume measurements were noted on images acquired by Signa Excite and Verio models. For some brain regions, significant MRI model effects were observed on certain segmentation results. Conclusions Short-term scan-rescan reliability of automatic brain MRI morphometry is feasible in the clinical setting. However, since repeatability of software performance is contingent on the reproducibility of the scanner performance, the scanner performance must be calibrated before conducting such studies or before using such software for retrospective reviewing. PMID:26812647

  2. Intraobserver reproducibility of parameters of standard and 2D speckle tracking echocardiography, dynamics of global longitudinal strain I in patients with acute primary anterior STEMI

    NASA Astrophysics Data System (ADS)

    Kercheva, M.; Ryabova, T.; Ryabov, V.; Karpov, R.

    2015-11-01

    The aim of this study was to assess the intraobserver reproducibility of parameters of standard and 2 dimensional speckle tracking echocardiography, dynamics of global longitudinal strain in patients with acute primary anterior STEMI. The study included 24 patients, mean age 58.46±10.2. Echocardiography with 2D speckle tracking imaging was performed on the 1st (T1), 7th (T2), 14th days (T3) after STEMI («Vivid E9»). Analysis of echocardiographic images was performed offline at the different periods by the two independent observers (EchoPac) - experienced and inexperienced. In order to assess the agreement between standard and 2D speckle tracking echocardiography, a correlation analysis (Pearson correlation, Spearman's rank correlation coefficient) and Bland-Altman analysis were undertaken. The 23 patients had urgent reperfusion therapy, 6 patients underwent primary PCI, 16 patients - PCI after successful fibrinolysis (68%). GLS and WMSI had the best intraobsever reproducibility. Dynamics of EDV LV, ESV LV, EF LV was without significant differences. Nevertheless, it was found positive dynamic of GLS: - 12.65±3.53 (T1), -13.61±3.81 (T2), -14.27±4.1 (T3), p<0.05. GLS reduced 11.35% (p=0.0048) from T1 to T3. The best intraobserver reproducibility of parameters of 2 D speckle-tracking and standard echocardiography was revealed in GLS and WMSI. The modern management of STEMI patients limits adverse postinfarction remodeling and preserves of global left ventricular contractility detected by the EF LV. However, GLS had the positive dynamics and improved to the 14th day.

  3. Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer.

    PubMed

    Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei

    2015-10-01

    To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. [Reproducibility of quantifying Timed Up and Go test, measured with smartphone accelerometers in older people living in the community].

    PubMed

    Campillay Guzmán, Jorge; Guzmán Silva, Ricardo; Guzmán-Venegas, Rodrigo

    Inertial Measurement Units (IMU) incorporated in smartphones can provide records that match registers obtained by laboratory instruments. This means that the use of smartphones would be feasible for recording three-dimensional kinematics parameters like velocity and acceleration, enabling more robust analyses, such as the Timed Up and Go (TUG) test, that assess the risk of falls older people (OP) living in the community. The study included 35 female OP, users of the Family Health Centres (CESFAM) Juan Pablo II and Corvallis from Antofagasta city, Chile. They were evaluated with the TUG, with linear and angular acceleration and velocity being recorded simultaneously using a smartphone equipped with a three-dimensional IMU. Using a computer macro application, the start and end time of each sub-stage of the test was determined by two independent observers. Reproducibility of the times of each sub-stage of TUG was assessed using the Intraclass Correlation Coefficient (ICC). The ICC gave values of 0.78 to 0.99, with an acceptable confidence interval, (0.45-1.00), thus providing a reproducible and reliable recording. The reproducibility of the times of the sub-stages of TUG, recorded with inertial measurement units from a smartphone enables it to be used in clinical practices with OP groups, in order to improve the evaluation and prevention of the risk of falls. Copyright © 2017 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Development and Assessment of a New Empirical Model for Predicting Full Creep Curves

    PubMed Central

    Gray, Veronica; Whittaker, Mark

    2015-01-01

    This paper details the development and assessment of a new empirical creep model that belongs to the limited ranks of models reproducing full creep curves. The important features of the model are that it is fully standardised and is universally applicable. By standardising, the user no longer chooses functions but rather fits one set of constants only. Testing it on 7 contrasting materials, reproducing 181 creep curves we demonstrate its universality. New model and Theta Projection curves are compared to one another using an assessment tool developed within this paper. PMID:28793458

  6. Validation of a global scale to assess the quality of interprofessional teamwork in mental health settings.

    PubMed

    Tomizawa, Ryoko; Yamano, Mayumi; Osako, Mitue; Hirabayashi, Naotugu; Oshima, Nobuo; Sigeta, Masahiro; Reeves, Scott

    2017-12-01

    Few scales currently exist to assess the quality of interprofessional teamwork through team members' perceptions of working together in mental health settings. The purpose of this study was to revise and validate an interprofessional scale to assess the quality of teamwork in inpatient psychiatric units and to use it multi-nationally. A literature review was undertaken to identify evaluative teamwork tools and develop an additional 12 items to ensure a broad global focus. Focus group discussions considered adaptation to different care systems using subjective judgements from 11 participants in a pre-test of items. Data quality, construct validity, reproducibility, and internal consistency were investigated in the survey using an international comparative design. Exploratory factor analysis yielded five factors with 21 items: 'patient/community centred care', 'collaborative communication', 'interprofessional conflict', 'role clarification', and 'environment'. High overall internal consistency, reproducibility, adequate face validity, and reasonable construct validity were shown in the USA and Japan. The revised Collaborative Practice Assessment Tool (CPAT) is a valid measure to assess the quality of interprofessional teamwork in psychiatry and identifies the best strategies to improve team performance. Furthermore, the revised scale will generate more rigorous evidence for collaborative practice in psychiatry internationally.

  7. Intact cell mass spectrometry (ICMS) used to type methicillin-resistant Staphylococcus aureus: media effects and inter-laboratory reproducibility.

    PubMed

    Walker, J; Fox, A J; Edwards-Jones, V; Gordon, D B

    2002-02-01

    Intact cell mass spectrometry (ICMS) rapidly analyses the surface composition of microorganisms providing rapid, discriminatory fingerprints for identification and subtyping of important nosocomial pathogens such as methicillin resistant Staphylocccus aureus (MRSA). In this study, ICMS using matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI TOF/MS) was assessed for the identification and subtyping of MRSA. An intra- and inter-laboratory reproducibility study was carried out and the effects of culture media (an important source of variation for ICMS) were also studied. Several media used for the cultural identification of MRSA were examined using a panel of well-characterised staphylococcal isolates (n=26). Six MRSA isolates were analysed over a 1-month period for intra-laboratory reproducibility on the same instrument and three different culture media. Spectra were consistent for each isolate between the four experiments on the same culture medium. Individual isolates produced different spectral profiles on different culture media. Spectra from organisms grown on Columbia blood agar contained more peaks (approximately 120) compared to Columbia agar (approximately 50) and methicillin mannitol salt agar (approximately 25). All 26 staphylococcal isolates were subjected to an inter-laboratory study on two MALDI instruments. For each isolate, the overall spectral profile was the same for each of the two instruments but the baseline threshold values was adjusted due to instrument differences in detector sensitivities. Differences between certain regions of the spectra reproducibly identified isolates belonging to the two major MRSA strains (EMRSA phage group 15 and 16). These results demonstrate ICMS with appropriate media selection is a rapid and reproducible technique for identification and discrimination of MRSA.

  8. Photographic Assessment of Baseline Fundus Morphology in the Comparison of Age-related Macular Degeneration Treatments Trials

    PubMed Central

    Grunwald, Juan E.; Daniel, Ebenezer; Ying, Gui-shuang; Pistilli, Maxwell; Maguire, Maureen G.; Alexander, Judith; Whittock-Martin, Revell; Parker, Candace R.; Sepielli, Krista; Blodi, Barbara A.; Martin, Daniel F.

    2012-01-01

    Objective To describe the methods used for assessment of baseline fundus characteristics from color photography and fluorescein angiography (FA) in the Comparison of the Age-Related Macular Degeneration Treatments Trials (CATT), and the relationship between these characteristics and visual acuity. Design Randomized, masked, multicenter trial. Participants This investigation included 1185 participants of the CATT study. Methods Baseline stereoscopic color fundus photographs and FAs of participants in the CATT study were assessed at a central fundus photograph reading center by masked readers. Replicate assessments of random samples of photographs were performed to assess intra- and inter-grader agreements. The association of the lesion characteristics with baseline visual acuity was assessed using analyses of variance and correlation coefficients. Main Outcome Measures Intra- and inter-grader reproducibility, visual acuity and lesion characteristics. Results Intra- and inter-grader reproducibility showed agreements ranging from 75% to 100% and weighted kappas ranging from 0.48 to 1.0 for qualitative determinations. The intra-class correlation coefficients were 0.96-0.97 for quantitative measurements of choroidal neovascularization (CNV) area and total area of CNV lesion. The mean visual acuity (SE) varied by the type of pathology in the foveal center: 64.5 (0.7) letters for fluid only, 59.0 (0.5) for CNV, and 58.7 (1.3) for hemorrhage (p<0.001). Fibrotic or atrophic scar present in the lesion, but not under the center of the fovea, was also associated with a markedly reduced visual acuity 48.4 (2.2), p<0.0001. Although total area of CNV lesion was weakly correlated with visual acuity when all participants were assessed (Spearman correlation coefficient ρ= −0.16, p<0.001), the correlation was stronger within patients with predominantly classic lesions (ρ=−0.42, p<0.001). Conclusions Our results show that the methodology used for grading CATT fundus images has good reproducibility. As expected, larger total CNV lesion area, and pathologic findings such as hemorrhage, fibrosis and atrophy at baseline are associated with decreased visual acuity. Financial Disclosures The authors have no proprietary or commercial interests in any materials discussed in this article. PMID:22512984

  9. Development and intra-institutional and inter-institutional validation of a comprehensive new hepatobiliary software: Part 1--Liver and gallbladder function.

    PubMed

    Krishnamurthy, Gerbail T; Krishnamurthy, Shakuntala; Gambhir, Sanjiv Sam; Rodrigues, Cesar; Rosenberg, Jarrett; Schiepers, Christiaan; Buxton-Thomas, Muriel

    2009-12-01

    To develop a software tool for quantification of liver and gallbladder function, and to assess the repeatability and reproducibility of measurements made with it. The software tool developed with the JAVA programming language uses the JAVA2 Standard Edition framework. After manual selection of the regions of interest on a 99mTc hepatic iminodiacetic acid study, the program calculates differential hepatic bile flow, basal duodeno-gastric bile reflux (B-DGBR), hepatic extraction fraction (HEF) of both the lobes with deconvolutional analysis and excretion half-time with nonlinear least squares fit. Gallbladder ejection fraction, ejection period (EP), ejection rate (ER), and postcholecystokinin (CCK) DGBR are calculated after stimulation with CCK-8. To assess intra-observer repeatability and intra-observer reproducibility, measurements from 10 normal participants were analyzed twice by three nuclear medicine technologists at the primary center. To assess inter-site reproducibility, measurements from a superset of 24 normal participants were also assessed once by three observers at the primary center and single observer at three other sites. For the 24 control participants, mean+/-SD of hepatic bile flow into gallbladder was 63.87+/-28.7%, HEF of the right lobe 100+/-0%, left lobe 99.43+2.63%, excretion half-time of the right lobe 21.50+6.98 min, left lobe 28.3+/-11.3 min. Basal DGBR was 1.2+/-1.0%. Gallbladder ejection fraction was 80+/-11%, EP 15.0+/-3.0 min, ER 5.8+/-1.6%/min, and DGBR-CCK 1.3+/-2.3%. Left and right lobe HEF was virtually identical across readers. All measures showed high repeatability except for gallbladder bile flow, basal DGBR, and EP, which exhibited marginal repeatability. Ejection fraction exhibited high reproducibility. There was high concordance among the three primary center observers except for basal DGBR, EP, and ER. Concordance between the primary site and one of the other sites was high, one was fair, and one was poor. New United States Food and Drug Administration-approved personal computer-based Krishnamurthy Hepato-Biliary Software for quantification of the liver and gallbladder function shows promise for consistently repeatable and reproducible results both within and between institutions, and may help to promote universal standardization of data acquisition and analysis in nuclear hepatology.

  10. Hippocampal volume change measurement: quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST.

    PubMed

    Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo

    2014-05-15

    To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1-year μL volume change, with LoA of ±218 μL for FreeSurfer, ±319 μL for expert manual delineation, and ±333 μL for FIRST. Approximate p-values indicated that reproducibility was better for FreeSurfer than for manual or FIRST, and that manual and FIRST did not differ. Inclusion of failed automated segmentations led to worsening of reproducibility of both automated methods for 1-year raw and percentage volume change. Quantitative reproducibility values of 1-year microliter and percentage hippocampal volume change were roughly similar between expert manual outlining, FIRST and FreeSurfer, but FreeSurfer reproducibility was statistically significantly superior to both manual outlining and FIRST after exclusion of failed segmentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. An efficient and reproducible method for improving growth of a soil alga (Chlorococcum infusionum) for toxicity assays.

    PubMed

    Nam, Sun-Hwa; An, Youn-Joo

    2015-12-01

    This study evaluated five methods of soil inoculation using the soil alga Chlorococcum infusionum to determine the most efficient and reproducible method for promoting the growth of soil algae for toxicity testing. The five techniques included application of C. infusionum in a circle on top of the soil, to a central spot on top of the soil, to a central spot in the subsoil, to one side on top of the soil, and application divided between a circle and a central spot on top of the soil. Of these, the first method generated the greatest amount of chlorophyll fluorescence and was the method with the best reproducibility. We evaluated the applicability of this method in an assessment of the toxicity of copper and nickel to C. infusionum in two representative standard soils. Copper (20-75 mg/kg for OECD soil and 20-60 mg/kg Lufa 2.2 soil) and nickel (400-500 mg/kg for OECD soil and 60-100 mg/kg Lufa 2.2 soil) reduced the chlorophyll fluorescence of C. infusionum when the inoculation was delivered in a circle on top of both soil types. To our knowledge, this is the first study to assess the suitability of different soil algal inoculation methods for terrestrial toxicity testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Screening of hearing in elderly people: assessment of accuracy and reproducibility of the whispered voice test.

    PubMed

    Labanca, Ludimila; Guimarães, Fernando Sales; Costa-Guarisco, Letícia Pimenta; Couto, Erica de Araújo Brandão; Gonçalves, Denise Utsch

    2017-11-01

    Given the high prevalence of presbycusis and its detrimental effect on quality of life, screening tests can be useful tools for detecting hearing loss in primary care settings. This study therefore aimed to determine the accuracy and reproducibility of the whispered voice test as a screening method for detecting hearing impairment in older people. This cross-sectional study was carried out with 210 older adults aged between 60 and 97 years who underwent the whispered voice test employing ten different phrases and using audiometry as a reference test. Sensitivity, specificity and positive and negative predictive values were calculated and accuracy was measured by calculating the area under the ROC curve. The test was repeated on 20% of the ears by a second examiner to assess inter-examiner reproducibility (IER). The words and phrases that showed the highest area under the curve (AUC) and IER values were: "shoe" (AUC = 0.918; IER = 0.877), "window" (AUC = 0.917; IER = 0.869), "it looks like it's going to rain" (AUC = 0.911; IER = 0.810), and "the bus is late" (AUC = 0.900; IER = 0.810), demonstrating that the whispered voice test is a useful screening tool for detecting hearing loss among older people. It is proposed that these words and phrases should be incorporated into the whispered voice test protocol.

  13. Translation, cultural adaptation and reproducibility of the Cochin Hand Functional Scale questionnaire for Brazil

    PubMed Central

    Chiari, Aline; de Souza Sardim, Carla Caires; Natour, Jamil

    2011-01-01

    OBJECTIVE: To translate, to perform a cultural adaptation of and to test the reproducibility of the Cochin Hand Functional Scale questionnaire for Brazil. METHODS: First, the Cochin Hand Functional Scale questionnaire was translated into Portuguese and was then back-translated into French. These translations were reviewed by a committee to establish a Brazilian version of the questionnaire to be tested. The validity and reproducibility of the Cochin Hand Functional Scale questionnaire was evaluated. Patients of both sexes, who were aged 18 to 60 years and presented with rheumatoid arthritis affecting their hands, were interviewed. The patients were initially interviewed by two observers and were later interviewed by a single rater. First, the Visual Analogue Scale for hand pain, the Arm, Shoulder and Hand Disability questionnaire and the Health Assessment Questionnaire were administered. The third administration of the Cochin Hand Functional Scale was performed fifteen days after the first administration. Ninety patients were assessed in the present study. RESULTS: Two questions were modified as a result of the assessment of cultural equivalence. The Cronbach's alpha value for this assessment was 0.93. The intraclass intraobserver and interobserver correlation coefficients were 0.76 and 0.96, respectively. The Spearman's coefficient indicated that there was a low level of correlation between the Cochin Hand Functional Scale and the Visual Analogue Scale for pain (0.46) and that there was a moderate level of correlation of the Cochin Scale with the Health Assessment Questionnaire (0.66) and with the Disability of the Arm, Shoulder and Hand questionnaire (0.63). The average administration time for the Cochin Scale was three minutes. CONCLUSION: The Brazilian version of the Cochin Hand Functional Scale was successfully translated and adapted, and this version exhibited good internal consistency, reliability and construct validity. PMID:21789372

  14. Development of a soy food frequency questionnaire to estimate isoflavone consumption in US adults.

    PubMed

    Kirk, P; Patterson, R E; Lampe, J

    1999-05-01

    To develop a dietary assessment instrument to measure soy food consumption and isoflavone intake and test it for reliability. A soy food frequency questionnaire, designed for use in this study, was administered twice to participants, separated by a 2-week interval. The questionnaire was tested for reproducibility of estimates of soy food consumption and isoflavone (genistein and daidzein) intake. A convenience sample of 51 faculty, staff, and students was recruited from a naturopathic university. Intraclass correlation coefficients were used to assess reproducibility of estimates of soy food intake and genistein and daidzein intake. Correlation coefficients comparing mean soy food servings per month between the 2 administrations of the questionnaire ranged from 0.50 for soy yogurt to 0.89 for tempeh. Correlation coefficients for genistein and daidzein intake estimated by the 2 administrations of the questionnaire were the same: 0.89. Mean intake (+/- standard deviation) of genistein and daidzein was 7 +/- 10 and 4 +/- 6 mg/day, respectively. Fifteen soy foods contributed 95% of the total genistein and daidzein intake: tofu, soy yogurt, tempeh, soy milk, low-fat tofu, soy flour, miso, soy protein isolate, low-fat soy milk, veggie soy burger, textured vegetable protein, miso soup, cooked soybeans, soy hot dogs, and natto (fermented soy beans). The soy food frequency questionnaire developed in this study provided highly reproducible estimates of soy food consumption and isoflavone intake. This instrument may be a useful tool in studies of the associations between isoflavone exposure and risk for chronic disease.

  15. A method for the design and development of medical or health care information websites to optimize search engine results page rankings on Google.

    PubMed

    Dunne, Suzanne; Cummins, Niamh Maria; Hannigan, Ailish; Shannon, Bill; Dunne, Colum; Cullen, Walter

    2013-08-27

    The Internet is a widely used source of information for patients searching for medical/health care information. While many studies have assessed existing medical/health care information on the Internet, relatively few have examined methods for design and delivery of such websites, particularly those aimed at the general public. This study describes a method of evaluating material for new medical/health care websites, or for assessing those already in existence, which is correlated with higher rankings on Google's Search Engine Results Pages (SERPs). A website quality assessment (WQA) tool was developed using criteria related to the quality of the information to be contained in the website in addition to an assessment of the readability of the text. This was retrospectively applied to assess existing websites that provide information about generic medicines. The reproducibility of the WQA tool and its predictive validity were assessed in this study. The WQA tool demonstrated very high reproducibility (intraclass correlation coefficient=0.95) between 2 independent users. A moderate to strong correlation was found between WQA scores and rankings on Google SERPs. Analogous correlations were seen between rankings and readability of websites as determined by Flesch Reading Ease and Flesch-Kincaid Grade Level scores. The use of the WQA tool developed in this study is recommended as part of the design phase of a medical or health care information provision website, along with assessment of readability of the material to be used. This may ensure that the website performs better on Google searches. The tool can also be used retrospectively to make improvements to existing websites, thus, potentially enabling better Google search result positions without incurring the costs associated with Search Engine Optimization (SEO) professionals or paid promotion.

  16. Improvement of Biological Indicators by Uniformly Distributing Bacillus subtilis Spores in Monolayers To Evaluate Enhanced Spore Decontamination Technologies

    PubMed Central

    Raguse, Marina; Fiebrandt, Marcel; Stapelmann, Katharina; Madela, Kazimierz; Laue, Michael; Lackmann, Jan-Wilm; Thwaite, Joanne E.; Setlow, Peter; Awakowicz, Peter

    2016-01-01

    Novel decontamination technologies, including cold low-pressure plasma and blue light (400 nm), are promising alternatives to conventional surface decontamination methods. However, the standardization of the assessment of such sterilization processes remains to be accomplished. Bacterial endospores of the genera Bacillus and Geobacillus are frequently used as biological indicators (BIs) of sterility. Ensuring standardized and reproducible BIs for reliable testing procedures is a significant problem in industrial settings. In this study, an electrically driven spray deposition device was developed, allowing fast, reproducible, and homogeneous preparation of Bacillus subtilis 168 spore monolayers on glass surfaces. A detailed description of the structural design as well as the operating principle of the spraying device is given. The reproducible formation of spore monolayers of up to 5 × 107 spores per sample was verified by scanning electron microscopy. Surface inactivation studies revealed that monolayered spores were inactivated by UV-C (254 nm), low-pressure argon plasma (500 W, 10 Pa, 100 standard cubic cm per min), and blue light (400 nm) significantly faster than multilayered spores were. We have thus succeeded in the uniform preparation of reproducible, highly concentrated spore monolayers with the potential to generate BIs for a variety of nonpenetrating surface decontamination techniques. PMID:26801572

  17. Six-minute walk test as a determinant of the functional capacity of children and adolescents with cystic fibrosis: A systematic review.

    PubMed

    Andrade Lima, Cibelle; Dornelas de Andrade, Armèle; Campos, Shirley Lima; Brandão, Daniella Cunha; Mourato, Ianny Pereira; Britto, Murilo Carlos Amorim de

    2018-04-01

    Cystic Fibrosis (CF) is a multisystem disorder. The involvement of the respiratory system is frequent and culminates in dyspnea and exercise intolerance. Functional capacity is an important diagnostic tool, because it reflects the cardiorespiratory status, quality of life and prognosis. This systematic review aims to assess the reproducibility and validity of the six minute walk test (6MWT) to reflect the functional capacity of children and adolescents with cystic fibrosis, and also the correlation between 6MWT and lung function. Searches for articles were performed in eight databases using MeSH/DeCS keywords. A total of 695 articles were found and, after verifying all eligibility criteria, six articles were included for analysis and scoring regarding the methodological quality according to the QUADAS scale (Quality Assessment of Diagnostic Accuracy Studies). All articles had good methodology (QUADAS between 9 and 11 points). The 6MWT is not correlated with lung function. There is a strong indication that the 6MWT is a reproducible test to assess the functional capacity of children and adolescents with CF. The validity assessment could not be reached because the studies included in this systematic review did not use adequate statistical tools to carry out such an evaluation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Estimates of DNA damage by the comet assay in the direct-developing frog Eleutherodactylus johnstonei (Anura, Eleutherodactylidae)

    PubMed Central

    Valencia, Laura Carolina; García, Adriana; Ramírez-Pinilla, Martha Patricia; Fuentes, Jorge Luis

    2011-01-01

    The aim of this study was to use the Comet assay to assess genetic damage in the direct-developing frog Eleutherodactylus johnstonei. A DNA diffusion assay was used to evaluate the effectiveness of alkaline, enzymatic and alkaline/enzymatic treatments for lysing E. johnstonei blood cells and to determine the amount of DNA strand breakage associated with apoptosis and necrosis. Cell sensitivity to the mutagens bleomycin (BLM) and 4-nitro-quinoline-1-oxide (4NQO) was also assessed using the Comet assay, as was the assay reproducibility. Alkaline treatment did not lyse the cytoplasmic and nuclear membranes of E. johnstonei blood cells, whereas enzymatic digestion with proteinase K (40 μg/mL) yielded naked nuclei. The contribution of apoptosis and necrosis (assessed by the DNA diffusion assay) to DNA damage was estimated to range from 0% to 8%. BLM and 4NQO induced DNA damage in E. johnstonei blood cells at different concentrations and exposure times. Dose-effect curves with both mutagens were highly reproducible and showed consistently low coefficients of variation (CV ≤ 10%). The results are discussed with regard to the potential use of the modified Comet assay for assessing the exposure of E. johnstonei to herbicides in ecotoxicological studies. PMID:22215974

  19. Estimates of DNA damage by the comet assay in the direct-developing frog Eleutherodactylus johnstonei (Anura, Eleutherodactylidae).

    PubMed

    Valencia, Laura Carolina; García, Adriana; Ramírez-Pinilla, Martha Patricia; Fuentes, Jorge Luis

    2011-10-01

    The aim of this study was to use the Comet assay to assess genetic damage in the direct-developing frog Eleutherodactylus johnstonei. A DNA diffusion assay was used to evaluate the effectiveness of alkaline, enzymatic and alkaline/enzymatic treatments for lysing E. johnstonei blood cells and to determine the amount of DNA strand breakage associated with apoptosis and necrosis. Cell sensitivity to the mutagens bleomycin (BLM) and 4-nitro-quinoline-1-oxide (4NQO) was also assessed using the Comet assay, as was the assay reproducibility. Alkaline treatment did not lyse the cytoplasmic and nuclear membranes of E. johnstonei blood cells, whereas enzymatic digestion with proteinase K (40 μg/mL) yielded naked nuclei. The contribution of apoptosis and necrosis (assessed by the DNA diffusion assay) to DNA damage was estimated to range from 0% to 8%. BLM and 4NQO induced DNA damage in E. johnstonei blood cells at different concentrations and exposure times. Dose-effect curves with both mutagens were highly reproducible and showed consistently low coefficients of variation (CV ≤ 10%). The results are discussed with regard to the potential use of the modified Comet assay for assessing the exposure of E. johnstonei to herbicides in ecotoxicological studies.

  20. A study of measurement properties of the Life-Space Assessment questionnaire in older adults with chronic obstructive pulmonary disease.

    PubMed

    Garcia, Isabel Fialho Fontenele; Tiuganji, Carina Tiemi; Simões, Maria do Socorro Morais Pereira; Lunardi, Adriana Claudia

    2018-06-01

    To test the measurement properties (reliability, interpretability, and validity) of the Life-Space Assessment questionnaire for older adults with chronic obstructive pulmonary disease. Clinimetric study. Pneumology service, ambulatory care, São Paulo, SP, Brazil. Consecutive sample of older adults ( n = 62; 38 (61%) men, 24 (39%) women) with chronic obstructive pulmonary disease. Not applicable. Life-Space Assessment questionnaire assesses five space levels visited by the older adult in four weeks prior to the assessment. We tested the following measurement properties of this questionnaire: reliability (reproducibility assessed by a type-2,1 intraclass correlation coefficient (ICC 2,1 ); internal consistency assessed by the Cronbach's alpha; measurement error by determining the standard error of measurement (SEM)), interpretability (minimum detectable change with 90% confidence (MDC 90 ); ceiling and floor effects by calculating the proportion of participants who achieved the minimum and maximum scores), and validity by Pearson's correlation test between the Life-Space Assessment questionnaire scores and number of daily steps assessed by accelerometry. Reproducibility (ICC 2,1 ) was 0.90 (95% confidence interval (CI): 0.84-0.94), and internal consistency (Cronbach's α) was 0.80 (range = 0.76-0.80 for each item deleted). SEM was 3.65 points (3%), the MDC 90 was 0.20 points, and we observed no ceiling (2%) or floor (6%) effects. We observed an association between the score of the Life-Space Assessment questionnaire and daily steps ( r = 0.43; P = 0.01). Life-Space Assessment questionnaire shows adequate measurement properties for the assessment of life-space mobility in older adults with chronic obstructive pulmonary disease.

  1. Reporting to Improve Reproducibility and Facilitate Validity Assessment for Healthcare Database Studies V1.0.

    PubMed

    Wang, Shirley V; Schneeweiss, Sebastian; Berger, Marc L; Brown, Jeffrey; de Vries, Frank; Douglas, Ian; Gagne, Joshua J; Gini, Rosa; Klungel, Olaf; Mullins, C Daniel; Nguyen, Michael D; Rassen, Jeremy A; Smeeth, Liam; Sturkenboom, Miriam

    2017-09-01

    Defining a study population and creating an analytic dataset from longitudinal healthcare databases involves many decisions. Our objective was to catalogue scientific decisions underpinning study execution that should be reported to facilitate replication and enable assessment of validity of studies conducted in large healthcare databases. We reviewed key investigator decisions required to operate a sample of macros and software tools designed to create and analyze analytic cohorts from longitudinal streams of healthcare data. A panel of academic, regulatory, and industry experts in healthcare database analytics discussed and added to this list. Evidence generated from large healthcare encounter and reimbursement databases is increasingly being sought by decision-makers. Varied terminology is used around the world for the same concepts. Agreeing on terminology and which parameters from a large catalogue are the most essential to report for replicable research would improve transparency and facilitate assessment of validity. At a minimum, reporting for a database study should provide clarity regarding operational definitions for key temporal anchors and their relation to each other when creating the analytic dataset, accompanied by an attrition table and a design diagram. A substantial improvement in reproducibility, rigor and confidence in real world evidence generated from healthcare databases could be achieved with greater transparency about operational study parameters used to create analytic datasets from longitudinal healthcare databases. © 2017 The Authors. Pharmacoepidemiology & Drug Safety Published by John Wiley & Sons Ltd.

  2. Reproducibility of flow mediated skin fluorescence to assess microvascular function.

    PubMed

    Hellmann, Marcin; Tarnawska, Maria; Dudziak, Maria; Dorniak, Karolina; Roustit, Matthieu; Cracowski, Jean-Luc

    2017-09-01

    Recent technical developments enable skin fluorescence to be quantified in vivo in humans. The present study aimed at determining whether flow mediated skin fluorescence was reproducible, sensitive to changes within an individual, and if it could differ between patients with coronary artery disease and healthy volunteers. First, forearm flow mediated skin fluorescence recorded during and after brachial artery occlusion was assessed following successive forearm occlusion periods (1, 2, 3 and 5min) and expressed as ischemic and hyperemic responses (as % of baseline). Secondly, 3min flow mediated skin fluorescence was assessed before and after 10min local cooling to 15°C. In a third protocol, the inter-day reproducibility of ischemic and hyperemic responses to 3min occlusion was tested at an interval of 7days, and compared between healthy controls and patients with coronary artery disease (CAD). In the first protocol, we observed a time dependent increase in the ischemic and hyperemic responses to occlusion. Next, we observed a lower hyperemic response after local cooling (9.8±4.2 versus 17.8±2.5% respectively, P<0.001), while in contrast, the ischemic response was higher and exhibited greater variability (23±15 versus 11.8±6.4%; P=0.028). In the third protocol, the inter-day reproducibility of flow mediated skin fluorescence for a 3min occlusion period was excellent. The ischemic response was significantly lower in CAD patients than in healthy controls (6.7±4.8% vs 14.7±6.8% respectively, P<0.001). Similarly, the hyperemic response was significantly decreased in the CAD group compared to healthy controls (11.6±3.6% vs 19.5±5.4% respectively, P<0.001). We show that quantifying the ischemic and hyperemic flow mediated skin fluorescence is feasible, reproducible, sensitive to acute changes in skin blood flow, and distinguishes patients populations. However, more data are needed to evaluate the correlation with other methods or specific biochemical endothelial markers. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Kaifang; Reinhardt, Joseph M.; Christensen, Gary E.

    2013-12-15

    Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients priormore » to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.« less

  4. Comparative Study of Solution Phase and Vapor Phase Deposition of Aminosilanes on Silicon Dioxide Surfaces

    PubMed Central

    Yadav, Amrita R.; Sriram, Rashmi; Carter, Jared A.; Miller, Benjamin L.

    2014-01-01

    The uniformity of aminosilane layers typically used for the modification of hydroxyl bearing surfaces such as silicon dioxide is critical for a wide variety of applications, including biosensors. However, in spite of many studies that have been undertaken on surface silanization, there remains a paucity of easy-to-implement deposition methods reproducibly yielding smooth aminosilane monolayers. In this study, solution- and vapor-phase deposition methods for three aminoalkoxysilanes differing in the number of reactive groups (3-aminopropyl triethoxysilane (APTES), 3-aminopropyl methyl diethoxysilane (APMDES) and 3-aminopropyl dimethyl ethoxysilane (APDMES)) were assessed with the aim of identifying methods that yield highly uniform and reproducible silane layers that are resistant to minor procedural variations. Silane film quality was characterized based on measured thickness, hydrophilicity and surface roughness. Additionally, hydrolytic stability of the films was assessed via these thickness and contact angle values following desorption in water. We found that two simple solution-phase methods, an aqueous deposition of APTES and a toluene based deposition of APDMES, yielded high quality silane layers that exhibit comparable characteristics to those deposited via vapor-phase methods. PMID:24411379

  5. Automated computation of femoral angles in dogs from three-dimensional computed tomography reconstructions: Comparison with manual techniques.

    PubMed

    Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M

    2018-02-01

    The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Improving the Asynchronous Video Learning Model

    ERIC Educational Resources Information Center

    Griffiths, Michael E.

    2010-01-01

    Online education is popular from a consumer perspective, but there are elements of face-to-face instruction and assessment that are difficult to reproduce online (Bassoppo-Moyo 2006). The difficulty of reproducing valued elements of a face-to-face setting leads to concerns regarding the overall quality of the online learning experience.…

  7. CO[subscript 2] Rebreathing: An Undergraduate Laboratory to Study the Chemical Control of Breathing

    ERIC Educational Resources Information Center

    Domnik, N. J.; Turcotte, S. E.; Yuen, N. Y.; Iscoe, S.; Fisher, J. T.

    2013-01-01

    The Read CO[subscript]2 rebreathing method (Read DJ. "A clinical method for assessing the ventilatory response to carbon dioxide." "Australas Ann Med" 16: 20-32, 1967) provides a simple and reproducible approach for studying the chemical control of breathing. It has been widely used since the modifications made by Duffin and…

  8. The definition and evaluation of the skills required to obtain a patient's history of illness: the use of videotape recordings

    PubMed Central

    Anderson, J.; Dowling, M. A. C.; Day, J. L.; Pettingale, K. W.

    1970-01-01

    Videotape recording apparatus was used to make records of case histories obtained from patients by students and doctors. These records were studied in order to identify the skills required to obtain a patient's history of illness. Each skill was defined. A questionnaire was developed in order to assess these skills and three independent observers watched the records of eighteen students and completed a questionnaire for each. The results of this were analysed for reliability and reproducibility between examiners. Moderate reliability and reproducibility were demonstrated. The questionnaire appeared to be a valid method of assessment and was capable of providing significant discrimination between students for each skill. A components analysis suggested that the marks for each skill depend on an overall impression obtained by each examiner and this overall impression is influenced by different skills for each examiner. PMID:5488220

  9. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method.

    PubMed

    Lázzari, J O; Pereira, M; Antunes, C M; Guimarães, A; Moncayo, A; Chávez Domínguez, R; Hernández Pieretti, O; Macedo, V; Rassi, A; Maguire, J; Romero, A

    1998-11-01

    An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG) tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (kappa) index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (kappa = 0.66; SE 0.02). While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  10. Common Data Models and Efficient Reproducible Workflows for Distributed Ocean Model Skill Assessment

    NASA Astrophysics Data System (ADS)

    Signell, R. P.; Snowden, D. P.; Howlett, E.; Fernandes, F. A.

    2014-12-01

    Model skill assessment requires discovery, access, analysis, and visualization of information from both sensors and models, and traditionally has been possible only by a few experts. The US Integrated Ocean Observing System (US-IOOS) consists of 17 Federal Agencies and 11 Regional Associations that produce data from various sensors and numerical models; exactly the information required for model skill assessment. US-IOOS is seeking to develop documented skill assessment workflows that are standardized, efficient, and reproducible so that a much wider community can participate in the use and assessment of model results. Standardization requires common data models for observational and model data. US-IOOS relies on the CF Conventions for observations and structured grid data, and on the UGRID Conventions for unstructured (e.g. triangular) grid data. This allows applications to obtain only the data they require in a uniform and parsimonious way using web services: OPeNDAP for model output and OGC Sensor Observation Service (SOS) for observed data. Reproducibility is enabled with IPython Notebooks shared on GitHub (http://github.com/ioos). These capture the entire skill assessment workflow, including user input, search, access, analysis, and visualization, ensuring that workflows are self-documenting and reproducible by anyone, using free software. Python packages for common data models are Pyugrid and the British Met Office Iris package. Python packages required to run the workflows (pyugrid, pyoos, and the British Met Office Iris package) are also available on GitHub and on Binstar.org so that users can run scenarios using the free Anaconda Python distribution. Hosted services such as Wakari enable anyone to reproduce these workflows for free, without installing any software locally, using just their web browser. We are also experimenting with Wakari Enterprise, which allows multi-user access from a web browser to an IPython Server running where large quantities of model output reside, increasing the efficiency. The open development and distribution of these workflows, and the software on which they depend, is an educational resource for those new to the field and a center of focus where practitioners can contribute new software and ideas.

  11. Validity of the International Physical Activity Questionnaire and the Singapore Prospective Study Program physical activity questionnaire in a multiethnic urban Asian population.

    PubMed

    Nang, Ei Ei Khaing; Gitau Ngunjiri, Susan Ayuko; Wu, Yi; Salim, Agus; Tai, E Shyong; Lee, Jeannette; Van Dam, Rob M

    2011-10-13

    Physical activity patterns of a population remain mostly assessed by the questionnaires. However, few physical activity questionnaires have been validated in Asian populations. We previously utilized a combination of different questionnaires to assess leisure time, transportation, occupational and household physical activity in the Singapore Prospective Study Program (SP2). The International Physical Activity Questionnaire (IPAQ) has been developed for a similar purpose. In this study, we compared estimates from these two questionnaires with an objective measure of physical activity in a multi-ethnic Asian population. Physical activity was measured in 152 Chinese, Malay and Asian Indian adults using an accelerometer over five consecutive days, including a weekend. Participants completed both the physical activity questionnaire in SP2 (SP2PAQ) and IPAQ long form. 43 subjects underwent a second set of measurements on average 6 months later to assess reproducibility of the questionnaires and the accelerometer measurements. Spearman correlations were used to evaluate validity and reproducibility and correlations for validity were corrected for within-person variation of accelerometer measurements. Agreement between the questionnaires and the accelerometer measurements was also evaluated using Bland Altman plots. The corrected correlation with accelerometer estimates of energy expenditure from physical activity was better for the SP2PAQ (vigorous activity: r = 0.73; moderate activity: r = 0.27) than for the IPAQ (vigorous activity: r = 0.31; moderate activity: r = 0.15). For moderate activity, the corrected correlation between SP2PAQ and the accelerometer was higher for Chinese (r = 0.38) and Malays (r = 0.57) than for Indians (r = -0.09). Both questionnaires overestimated energy expenditure from physical activity to a greater extent at higher levels of physical activity than at lower levels of physical activity. The reproducibility for moderate activity (accelerometer: r = 0.68; IPAQ: r = 0.58; SP2PAQ: r = 0.55) and vigorous activity (accelerometer: 0.52; IPAQ: r = 0.38; SP2PAQ: r = 0.75) was moderate to high for all instruments. The agreement between IPAQ and accelerometer measurements of energy expenditure from physical activity was poor in our Asian study population. The SP2PAQ showed good validity and reproducibility for vigorous activity, but performed less well for moderate activity particularly in Indians. Further effort is needed to develop questionnaires that better capture moderate activity in Asian populations.

  12. Reproducibility and repeatability of semi-quantitative 18F-fluorodihydrotestosterone (FDHT) uptake metrics in castration-resistant prostate cancer metastases: a prospective multi-center study.

    PubMed

    Vargas, Hebert Alberto; Kramer, Gem M; Scott, Andrew M; Weickhardt, Andrew; Meier, Andreas A; Parada, Nicole; Beattie, Bradley J; Humm, John L; Staton, Kevin D; Zanzonico, Pat B; Lyashchenko, Serge K; Lewis, Jason S; Yaqub, Maqsood; Sosa, Ramon E; van den Eertwegh, Alfons J; Davis, Ian D; Ackermann, Uwe; Pathmaraj, Kunthi; Schuit, Robert C; Windhorst, Albert D; Chua, Sue; Weber, Wolfgang A; Larson, Steven M; Scher, Howard I; Lammertsma, Adriaan A; Hoekstra, Otto; Morris, Michael J

    2018-04-06

    18 F-fluorodihydrotestosterone ( 18 F-FDHT) is a radiolabeled analogue of the androgen receptor's primary ligand that is currently being credentialed as a biomarker for prognosis, response, and pharmacodynamic effects of new therapeutics. As part of the biomarker qualification process, we prospectively assessed its reproducibility and repeatability in men with metastatic castration-resistant prostate cancer (mCRPC). Methods: We conducted a prospective multi-institutional study of mCRPC patients undergoing two (test/re-test) 18 F-FDHT PET/CT scans on two consecutive days. Two independent readers evaluated all examinations and recorded standardized uptake values (SUVs), androgen receptor-positive tumor volumes (ARTV), and total lesion uptake (TLU) for the most avid lesion detected in each of 32 pre-defined anatomical regions. The relative absolute difference and reproducibility coefficient (RC) of each metric were calculated between the test and re-test scans. Linear regression analyses, intra-class correlation coefficients (ICC), and Bland-Altman plots were used to evaluate repeatability of 18 F-FDHT metrics. The coefficient of variation (COV) and ICC were used to assess inter-observer reproducibility. Results: Twenty-seven patients with 140 18 F-FDHT-avid regions were included. The best repeatability among 18 F-FDHT uptake metrics was found for SUV metrics (SUV max , SUVmean, and SUVpeak), with no significant differences in repeatability found among them. Correlations between the test and re-test scans were strong for all SUV metrics (R2 ≥ 0.92; ICC ≥ 0.97). The RCs of the SUV metrics ranged from 21.3% for SUVpeak to 24.6% for SUV max The test and re-test ARTV and TLU, respectively, were highly correlated (R2 and ICC ≥ 0.97), although variability was significantly higher than that for SUV (RCs > 46.4%). The PSA levels, Gleason score, weight, and age did not affect repeatability, nor did total injected activity, uptake measurement time, or differences in uptake time between the two scans. Including the single most avid lesion per patient, the five most avid lesions per patient, only lesions ≥ 4.2 mL, only lesions with an SUV ≥ 4 g/mL, or normalizing of SUV to area under the parent plasma activity concentration-time curve did not significantly affect repeatability. All metrics showed high inter-observer reproducibility (ICC > 0.98; COV < 0.2-10.8%). Conclusion: 18 F-FDHT is a highly reproducible means of imaging mCRPC. Amongst 18 F-FDHT uptake metrics, SUV had the highest repeatability among the measures assessed. These performance characteristics lend themselves to further biomarker development and clinical qualification of the tracer. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. THE POWER TO DETECT A DIFFERENCE: DETERMINING SAMPLE SIZE REQUIREMENTS FOR EVALUATION OF REPRODUCTIVE/DEVELOPMENTAL EFFECTS FROM EXPOSURE TO COMPLEX MIXTURES OF DISINFECTION BYPRODUCTS

    EPA Science Inventory

    Toxicological assessment of environmentally-realistic complex mixtures of drinking-water disinfection byproducts (DBPs) are needed to address concerns raised by some epidemiological studies showing associations between exposure to chemically disinfected water and adverse reproduc...

  14. Ambulatory Assessment in Panic Disorder and Specific Phobia

    ERIC Educational Resources Information Center

    Alpers, Georg W.

    2009-01-01

    Anxiety disorders are among the most prevalent mental disorders. In panic disorder, panic attacks often occur at unpredictable times, making it difficult to study these episodes in the laboratory. In specific phobias, symptoms occur in very circumscribed situations and specific triggers are sometimes difficult to reproduce in the laboratory.…

  15. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.

    PubMed

    Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J

    2010-07-27

    Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  16. Voxel size dependency, reproducibility and sensitivity of an in vivo bone loading estimation algorithm

    PubMed Central

    Christen, Patrik; Schulte, Friederike A.; Zwahlen, Alexander; van Rietbergen, Bert; Boutroy, Stephanie; Melton, L. Joseph; Amin, Shreyasee; Khosla, Sundeep; Goldhahn, Jörg; Müller, Ralph

    2016-01-01

    A bone loading estimation algorithm was previously developed that provides in vivo loading conditions required for in vivo bone remodelling simulations. The algorithm derives a bone's loading history from its microstructure as assessed by high-resolution (HR) computed tomography (CT). This reverse engineering approach showed accurate and realistic results based on micro-CT and HR-peripheral quantitative CT images. However, its voxel size dependency, reproducibility and sensitivity still need to be investigated, which is the purpose of this study. Voxel size dependency was tested on cadaveric distal radii with micro-CT images scanned at 25 µm and downscaled to 50, 61, 75, 82, 100, 125 and 150 µm. Reproducibility was calculated with repeated in vitro as well as in vivo HR-pQCT measurements at 82 µm. Sensitivity was defined using HR-pQCT images from women with fracture versus non-fracture, and low versus high bone volume fraction, expecting similar and different loading histories, respectively. Our results indicate that the algorithm is voxel size independent within an average (maximum) error of 8.2% (32.9%) at 61 µm, but that the dependency increases considerably at voxel sizes bigger than 82 µm. In vitro and in vivo reproducibility are up to 4.5% and 10.2%, respectively, which is comparable to other in vitro studies and slightly higher than in other in vivo studies. Subjects with different bone volume fraction were clearly distinguished but not subjects with and without fracture. This is in agreement with bone adapting to customary loading but not to fall loads. We conclude that the in vivo bone loading estimation algorithm provides reproducible, sensitive and fairly voxel size independent results at up to 82 µm, but that smaller voxel sizes would be advantageous. PMID:26790999

  17. Assessment of the Validity and Reproducibility of a Novel Standardized Test Meal for the Study of Postprandial Triacylglycerol Concentrations.

    PubMed

    Tentolouris, Nikolaos; Kanellos, Panagiotis T; Siami, Evangelia; Athanasopoulou, Elpida; Chaviaras, Nikolaos; Kolovou, Genovefa; Sfikakis, Petros P; Katsilambros, Nikolaos

    2017-08-01

    Lipotest ® is a standardized fat-rich meal designed for use as a test meal during a fat tolerance test (FTT) for the study of postprandial triacylglycerol (TAG) concentrations. Herein we examined the precision and reproducibility of examination using Lipotest ® on postprandial TAG levels. A total of 26 healthy consenting subjects were examined twice after 8-10 h fasting with an interval of approximately 1 week apart. Blood samples were collected at baseline and 1, 2, 3, and 4 h after consumption of the test meal for measurement of plasma total TAG levels. We examined agreement, precision, and accuracy between the two visits using the Altman plots and correlation coefficient. Reproducibility was tested using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Moreover, the area under the curve (AUC) as a summary measure of the overall postprandial TAG levels was calculated. The agreement, precision (r ≥ 0.74, p < 0.001), and accuracy (≥0.99) between the measurements in plasma TAG during Lipotest ® testing in the two visits were high. In terms of reproducibility, the values of CV were 15.59-23.83% while those of ICC were ≥0.75. The values of the AUCs in the visits were not different (p = 0.87). A single measurement of plasma TAG levels at 4 h after Lipotest ® consumption depicted peak postprandial TAG concentration. A FTT using Lipotest ® as a standardized meal has good precision and reproducibility for the study of postprandial TAG levels in healthy individuals. A single determination of plasma TAG concentration at 4 h after Lipotest ® consumption captures peak postprandial TAG response.

  18. Evaluation of New Cone-beam Computed Tomographic Criteria for Radiographic Healing Evaluation after Apical Surgery: Assessment of Repeatability and Reproducibility.

    PubMed

    von Arx, Thomas; Janner, Simone F M; Hänni, Stefan; Bornstein, Michael M

    2016-02-01

    Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Reproducibility of a peripheral quantitative computed tomography scan protocol to measure the material properties of the second metatarsal.

    PubMed

    Chaplais, Elodie; Greene, David; Hood, Anita; Telfer, Scott; du Toit, Verona; Singh-Grewal, Davinder; Burns, Joshua; Rome, Keith; Schiferl, Daniel J; Hendry, Gordon J

    2014-07-19

    Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec(-1). The reference line was positioned at the most distal portion of the 2(nd) metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI - mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI - mid shaft (ICC 0.99; CV% 3.2). The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2(nd) metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures.

  20. Reproducibility of a peripheral quantitative computed tomography scan protocol to measure the material properties of the second metatarsal

    PubMed Central

    2014-01-01

    Background Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Methods Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec-1. The reference line was positioned at the most distal portion of the 2nd metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Results Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI – mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI – mid shaft (ICC 0.99; CV% 3.2). Conclusions The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2nd metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures. PMID:25037451

  1. Reproducibility of subjective appetite ratings and ad libitum test meal energy intake in overweight and obese males.

    PubMed

    Horner, Katy M; Byrne, Nuala M; King, Neil A

    2014-10-01

    To determine whether changes in appetite and energy intake (EI) can be detected and play a role in the effectiveness of interventions, it is necessary to identify their variability under normal conditions. We assessed the reproducibility of subjective appetite ratings and ad libitum test meal EI after a standardised pre-load in overweight and obese males. Fifteen overweight and obese males (BMI 30.3 ± 4.9 kg/m(2), aged 34.9 ± 10.6 years) completed two identical test days, 7 days apart. Participants were provided with a standardised fixed breakfast (1676 kJ) and 5 h later an ad libitum pasta lunch. An electronic appetite rating system was used to assess subjective ratings before and after the fixed breakfast, and periodically during the postprandial period. EI was assessed at the ad libitum lunch meal. Sample size estimates for paired design studies were calculated. Appetite ratings demonstrated a consistent oscillating pattern between test days, and were more reproducible for mean postprandial than fasting ratings. The correlation between ad libitum EI on the two test days was r = 0.78 (P <0.01). Using a paired design and a power of 0.8, a minimum of 12 participants would be needed to detect a 10 mm change in 5 h postprandial mean ratings and 17 to detect a 500 kJ difference in ad libitum EI. Intra-individual variability of appetite and ad libitum test meal EI in overweight and obese males is comparable to previous reports in normal weight adults. Sample size requirements for studies vary depending on the parameter of interest and sensitivity needed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Current whole-body MRI applications in the neurofibromatoses: NF1, NF2, and schwannomatosis.

    PubMed

    Ahlawat, Shivani; Fayad, Laura M; Khan, Muhammad Shayan; Bredella, Miriam A; Harris, Gordon J; Evans, D Gareth; Farschtschi, Said; Jacobs, Michael A; Chhabra, Avneesh; Salamon, Johannes M; Wenzel, Ralph; Mautner, Victor F; Dombi, Eva; Cai, Wenli; Plotkin, Scott R; Blakeley, Jaishri O

    2016-08-16

    The Response Evaluation in Neurofibromatosis and Schwannomatosis (REiNS) International Collaboration Whole-Body MRI (WB-MRI) Working Group reviewed the existing literature on WB-MRI, an emerging technology for assessing disease in patients with neurofibromatosis type 1 (NF1), neurofibromatosis type 2 (NF2), and schwannomatosis (SWN), to recommend optimal image acquisition and analysis methods to enable WB-MRI as an endpoint in NF clinical trials. A systematic process was used to review all published data about WB-MRI in NF syndromes to assess diagnostic accuracy, feasibility and reproducibility, and data about specific techniques for assessment of tumor burden, characterization of neoplasms, and response to therapy. WB-MRI at 1.5T or 3.0T is feasible for image acquisition. Short tau inversion recovery (STIR) sequence is used in all investigations to date, suggesting consensus about the utility of this sequence for detection of WB tumor burden in people with NF. There are insufficient data to support a consensus statement about the optimal imaging planes (axial vs coronal) or 2D vs 3D approaches. Functional imaging, although used in some NF studies, has not been systematically applied or evaluated. There are no comparative studies between regional vs WB-MRI or evaluations of WB-MRI reproducibility. WB-MRI is feasible for identifying tumors using both 1.5T and 3.0T systems. The STIR sequence is a core sequence. Additional investigation is needed to define the optimal approach for volumetric analysis, the reproducibility of WB-MRI in NF, and the diagnostic performance of WB-MRI vs regional MRI. © 2016 American Academy of Neurology.

  3. A new rapid method to measure human platelet cholesterol: a pilot study.

    PubMed

    Jagroop, I Anita; Persaud, Jahm Want; Mikhailidis, Dimitri P

    2011-01-01

    Platelet cholesterol (PC) could be used to assess "tissue" cholesterol of patients with vascular disease. However, the methods available so far to measure PC involve a complex extraction process. We developed a rapid method to measure PC and assessed its correlation with serum total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), LDL-C/HDL-C ratio, triglycerides (TG), and non-HDL-C. We assessed repeatability (20 times, 3 participants) and reproducibility (8 times, 2 participants). A group of 47 healthy participants was studied. Blood was collected to analyze serum TC, LDL-C, HDL-C, and TG. Citrated blood was used to prepare a platelet pellet. A "clear soup" was produced (by disrupting this pellet using freeze-thaw and sonication cycles) and used to measure PC. Repeatability of PC showed a coefficient of variation (CV) of 4.8%. The reproducibility of PC over a period of 2 months was CV 7.5% and 8.1% (8 measurements for 2 participants). The PC of participants with serum LDL-C >2.6 mmol/L (treatment goal recommended by the National Cholesterol Education Program Adult Treatment Panel III) was 377 ± 120 μmol/10(12) platelets (n = 25). There was a significant correlation (Spearman, correlation coefficient) of PC (n = 25) with serum LDL-C (r(s) = 0.45, P = .02), LDL-C/HDL-C (r(s) = 0.45, P = .02), TG (r(s) = 0.43, P = .03), and non-HDL-C (r(s) = 0.53, P = .007). This technique of measuring PC has the advantage of being reproducible, fast, and simpler than previous methods. Thus, it may be useful for multiple sampling when investigating changes in PC in hypercholesterolemic patients. More extensive evaluation is necessary.

  4. Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    PubMed

    Clément, Julien; Raison, Maxime; Rouleau, Dominique M

    2018-02-08

    None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Detection of animal-derived proteins in feedstuffs in Italy: a reproducibility study.

    PubMed

    Ingravalle, Francesco; Abete, Maria Cesarina; Crescio, Maria Ines; Ru, Giuseppe

    2007-04-01

    Bovine spongiform encephalopathy is a prion disease of ruminants that was first recognized in 1986 in the United Kingdom. Early in the epidemic, it became obvious that the presence of meat and bone meal in feed rations was a common factor in all bovine spongiform encephalopathy cases. The first ban of derived animal proteins in feed was enforced in Europe in 1994 and implemented by Regulation 999/2001 that prohibited the feeding of animal-derived protein to farm animals. The only official method currently accepted by the European Union Commission for test for the presence of animal-derived proteins in feedstuffs is feed microscopy. In Italy, monitoring of feedstuff safety is provided by both the Ministry of Health and the Ministry of Agriculture. The quality of official control, usually assessed by verifying the reproducibility and the accuracy of the testing method, is of fundamental importance for all laboratories and institutions using these results for comparative purposes. The aims of this study were to assess the reproducibility of the official method over all the Italian surveillance network and to provide a model for evaluating the performance of the monitoring system. The accuracy of the identification of the animal class of derived protein detected (avian, mammalian, or aquatic organism) was assessed. The interlaboratory agreement within the overall network reached 0.97 (95% confidence interval of 0.95 to 0.98) for determining the presence or absence of animal-derived proteins (e.g., for mammalian, avian, or aquatic species), and specificity of the identification of the animal class indicated that fish proteins are more easily recognized than are avian or mammalian proteins.

  6. Ecological Momentary Assessment Methodology in Chronic Pain Research: A Systematic Review.

    PubMed

    May, Marcella; Junghaenel, Doerte U; Ono, Masakatsu; Stone, Arthur A; Schneider, Stefan

    2018-01-31

    Self-reported pain intensity assessments are central to chronic pain research. Ecological momentary assessment (EMA) methodologies are uniquely positioned to collect these data, and are indeed being used in the field. However, EMA protocols are complex, and many decisions are necessary in the design of EMA research studies. A systematic literature review identified 105 articles drawing from 62 quantitative EMA research projects examining pain intensity in adult chronic pain patients. Study characteristics were tabulated to summarize and describe the use of EMA, with an emphasis placed on various dimensions of decision-making involved in executing EMA methodologies. Most identified studies considered within-person relationships between pain and other variables, and a few examined interventions on chronic pain. There was a trend toward the use of smartphones as EMA data collection devices more recently, and completion rates were not reported in nearly one third of studies. Pain intensity items varied widely with respect to number of scale points, anchor labels, and length of reporting period; most used numeric rating scales. Recommendations are provided for reporting to improve reproducibility, comparability, and interpretation of results, and for opportunities to clarify the importance of design decisions. Studies that use EMA methodologies to assess pain intensity are heterogeneous. Aspects of protocol design, including data input modality and pain item construction, have the potential to influence the data collected. Thorough reporting on design features and completion rates therefore facilitates reproducibility, comparability, and interpretation of study results. Copyright © 2018 The American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. Guidelines to electrode positioning for human and animal electrical impedance myography research

    NASA Astrophysics Data System (ADS)

    Sanchez, Benjamin; Pacheck, Adam; Rutkove, Seward B.

    2016-09-01

    The positioning of electrodes in electrical impedance myography (EIM) is critical for accurately assessing disease progression and effectiveness of treatment. In human and animal trials for neuromuscular disorders, inconsistent electrode positioning adds errors to the muscle impedance. Despite its importance, how the reproducibility of resistance and reactance, the two parameters that define EIM, are affected by changes in electrode positioning remains unknown. In this paper, we present a novel approach founded on biophysical principles to study the reproducibility of resistance and reactance to electrode misplacements. The analytical framework presented allows the user to quantify a priori the effect on the muscle resistance and reactance using only one parameter: the uncertainty placing the electrodes. We also provide quantitative data on the precision needed to position the electrodes and the minimum muscle length needed to achieve a pre-specified EIM reproducibility. The results reported here are confirmed with finite element model simulations and measurements on five healthy subjects. Ultimately, our data can serve as normative values to enhance the reliability of EIM as a biomarker and facilitate comparability of future human and animal studies.

  8. Development of standard operating procedures to obtain longitudinal vaginal specimens from nulliparous rabbits as part of HIV vaccine mucosal immunogenicity studies.

    PubMed

    Gómez Román, Victor Raúl; Vinner, Lasse; Grevstad, Berit; Hansen, Jesper Juhl; Wegmann, Frank; Spetz, Anna-Lena; Fomsgaard, Anders

    2010-12-15

    The New Zealand white rabbit model (Oryctolagus cuniculus) is widely used to test whether HIV vaccine candidates elicit systemic antibody responses; however, its use in mucosal immunology has not been fully exploited due to the difficulty in collecting mucosal specimens longitudinally and reproducibly. Here we describe feasible and non-feasible methods to collect vaginal and nasal specimens from nulliparous rabbits. Non-feasible methods were those resulting in poor reproducibility and considerable animal twitching during sampling, whereas feasible methods resulted in no animal twitching and potential for sampling reproducibility. Standard operating procedures (SOPs) were implemented to collect vaginal swabs yielding total IgA titres ranging from 12,500 to 312,500. Intranasal immunisation with a naked DNA vaccine encoding HIV gp140 elicited HIV envelope-specific IgA detectable in nasal but not in vaginal secretions. Our methods provide an alternative to reliably assess pre- and post-vaccination mucosal antibody titres longitudinally in rabbits as part of mucosal HIV vaccine immunogenicity studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. 32 CFR 2700.33 - Mandatory review for declassification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... made more specific, no further action will be taken. (4) Subject to paragraph (b)(7) of this section... one hour. (ii) Reproduction of documents: Documents will be reproduced at a rate of $.25 per page for all copying of four pages or more. No fee shall be assessed for reproducing documents which are three...

  10. 32 CFR 2700.33 - Mandatory review for declassification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... made more specific, no further action will be taken. (4) Subject to paragraph (b)(7) of this section... one hour. (ii) Reproduction of documents: Documents will be reproduced at a rate of $.25 per page for all copying of four pages or more. No fee shall be assessed for reproducing documents which are three...

  11. 32 CFR 2700.33 - Mandatory review for declassification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... made more specific, no further action will be taken. (4) Subject to paragraph (b)(7) of this section... one hour. (ii) Reproduction of documents: Documents will be reproduced at a rate of $.25 per page for all copying of four pages or more. No fee shall be assessed for reproducing documents which are three...

  12. Most blood biomarkers related to vitamin status, one-carbon metabolism, and the kynurenine pathway show adequate preanalytical stability and within-person reproducibility to allow assessment of exposure or nutritional status in healthy women and cardiovascular patients.

    PubMed

    Midttun, Oivind; Townsend, Mary K; Nygård, Ottar; Tworoger, Shelley S; Brennan, Paul; Johansson, Mattias; Ueland, Per Magne

    2014-05-01

    Knowledge of stability during sample transportation and changes in biomarker concentrations within person over time are paramount for proper design and interpretation of epidemiologic studies based on a single measurement of biomarker status. Therefore, we investigated stability and intraindividual vs. interindividual variation in blood concentrations of biomarkers related to vitamin status, one-carbon metabolism, and the kynurenine pathway. Whole blood (EDTA and heparin, n = 12) was stored with an icepack for 24 or 48 h, and plasma concentrations of 38 biomarkers were determined. Stability was calculated as change per hour, intraclass correlation coefficient (ICC), and simple Spearman correlation. Within-person reproducibility of biomarkers was expressed as ICC in samples collected 1-2 y apart from 40 postmenopausal women and in samples collected up to 3 y apart from 551 patients with stable angina pectoris. Biomarker stability was similar in EDTA and heparin blood. Most biomarkers were essentially stable, except for choline and total homocysteine (tHcy), which increased markedly. Within-person reproducibility in postmenopausal women was excellent (ICC > 0.75) for cotinine, all-trans retinol, cobalamin, riboflavin, α-tocopherol, Gly, pyridoxal, methylmalonic acid, creatinine, pyridoxal 5'-phosphate, and Ser; was good to fair (ICC of 0.74-0.40) for pyridoxic acid, kynurenine, tHcy, cholecalciferol, flavin mononucleotide, kynurenic acid, xanthurenic acid, 3-hydroxykynurenine, sarcosine, anthranilic acid, cystathionine, homoarginine, 3-hydroxyanthranilic acid, betaine, Arg, folate, total cysteine, dimethylglycine, asymmetric dimethylarginine, neopterin, symmetric dimethylarginine, and Trp; and poor (ICC of 0.39-0.15) for methionine sulfoxide, Met, choline, and trimethyllysine. Similar reproducibilities were observed in patients with coronary heart disease. Thus, most biomarkers investigated were essentially stable in cooled whole blood for up to 48 h and had a sufficient within-person reproducibility to allow one-exposure assessment of biomarker status in epidemiologic studies. The Western Norway B Vitamin Intervention Trial was registered at clinicaltrials.gov as NTC00354081.

  13. Reproducibility of MRI-Determined Proton Density Fat Fraction Across Two Different MR Scanner Platforms

    PubMed Central

    Kang, Geraldine H.; Cruite, Irene; Shiehmorteza, Masoud; Wolfson, Tanya; Gamst, Anthony C.; Hamilton, Gavin; Bydder, Mark; Middleton, Michael S.; Sirlin, Claude B.

    2016-01-01

    Purpose To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. Materials and Methods This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. Results 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/−0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. Conclusion MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T. PMID:21769986

  14. Reproducibility of MRI-determined proton density fat fraction across two different MR scanner platforms.

    PubMed

    Kang, Geraldine H; Cruite, Irene; Shiehmorteza, Masoud; Wolfson, Tanya; Gamst, Anthony C; Hamilton, Gavin; Bydder, Mark; Middleton, Michael S; Sirlin, Claude B

    2011-10-01

    To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/-0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T. Copyright © 2011 Wiley-Liss, Inc.

  15. Performance assessment of a programmable five degrees-of-freedom motion platform for quality assurance of motion management techniques in radiotherapy.

    PubMed

    Huang, Chen-Yu; Keall, Paul; Rice, Adam; Colvill, Emma; Ng, Jin Aun; Booth, Jeremy T

    2017-09-01

    Inter-fraction and intra-fraction motion management methods are increasingly applied clinically and require the development of advanced motion platforms to facilitate testing and quality assurance program development. The aim of this study was to assess the performance of a 5 degrees-of-freedom (DoF) programmable motion platform HexaMotion (ScandiDos, Uppsala, Sweden) towards clinically observed tumor motion range, velocity, acceleration and the accuracy requirements of SABR prescribed in AAPM Task Group 142. Performance specifications for the motion platform were derived from literature regarding the motion characteristics of prostate and lung tumor targets required for real time motion management. The performance of the programmable motion platform was evaluated against (1) maximum range, velocity and acceleration (5 DoF), (2) static position accuracy (5 DoF) and (3) dynamic position accuracy using patient-derived prostate and lung tumor motion traces (3 DoF). Translational motion accuracy was compared against electromagnetic transponder measurements. Rotation was benchmarked with a digital inclinometer. The static accuracy and reproducibility for translation and rotation was <0.1 mm or <0.1°, respectively. The accuracy of reproducing dynamic patient motion was <0.3 mm. The motion platform's range met the need to reproduce clinically relevant translation and rotation ranges and its accuracy met the TG 142 requirements for SABR. The range, velocity and acceleration of the motion platform are sufficient to reproduce lung and prostate tumor motion for motion management. Programmable motion platforms are valuable tools in the investigation, quality assurance and commissioning of motion management systems in radiation oncology.

  16. A Reliable and Reproducible Model for Assessing the Effect of Different Concentrations of α-Solanine on Rat Bone Marrow Mesenchymal Stem Cells.

    PubMed

    Ordóñez-Vásquez, Adriana; Jaramillo-Gómez, Lorenza; Duran-Correa, Camilo; Escamilla-García, Erandi; De la Garza-Ramos, Myriam Angélica; Suárez-Obando, Fernando

    2017-01-01

    Αlpha-solanine ( α -solanine) is a glycoalkaloid present in potato (Solanum tuberosum) . It has been of particular interest because of its toxicity and potential teratogenic effects that include abnormalities of the central nervous system, such as exencephaly, encephalocele, and anophthalmia. Various types of cell culture have been used as experimental models to determine the effect of α -solanine on cell physiology. The morphological changes in the mesenchymal stem cell upon exposure to α -solanine have not been established. This study aimed to describe a reliable and reproducible model for assessing the structural changes induced by exposure of mouse bone marrow mesenchymal stem cells (MSCs) to different concentrations of α -solanine for 24 h. The results demonstrate that nonlethal concentrations of α -solanine (2-6  μ M) changed the morphology of the cells, including an increase in the number of nucleoli, suggesting elevated protein synthesis, and the formation of spicules. In addition, treatment with α -solanine reduced the number of adherent cells and the formation of colonies in culture. Immunophenotypic characterization and staining of MSCs are proposed as a reproducible method that allows description of cells exposed to the glycoalkaloid, α -solanine.

  17. A Reliable and Reproducible Model for Assessing the Effect of Different Concentrations of α-Solanine on Rat Bone Marrow Mesenchymal Stem Cells

    PubMed Central

    Ordóñez-Vásquez, Adriana; Jaramillo-Gómez, Lorenza; Duran-Correa, Camilo

    2017-01-01

    Αlpha-solanine (α-solanine) is a glycoalkaloid present in potato (Solanum tuberosum). It has been of particular interest because of its toxicity and potential teratogenic effects that include abnormalities of the central nervous system, such as exencephaly, encephalocele, and anophthalmia. Various types of cell culture have been used as experimental models to determine the effect of α-solanine on cell physiology. The morphological changes in the mesenchymal stem cell upon exposure to α-solanine have not been established. This study aimed to describe a reliable and reproducible model for assessing the structural changes induced by exposure of mouse bone marrow mesenchymal stem cells (MSCs) to different concentrations of α-solanine for 24 h. The results demonstrate that nonlethal concentrations of α-solanine (2–6 μM) changed the morphology of the cells, including an increase in the number of nucleoli, suggesting elevated protein synthesis, and the formation of spicules. In addition, treatment with α-solanine reduced the number of adherent cells and the formation of colonies in culture. Immunophenotypic characterization and staining of MSCs are proposed as a reproducible method that allows description of cells exposed to the glycoalkaloid, α-solanine. PMID:29201465

  18. Assessment of four midcarpal radiologic determinations.

    PubMed

    Cho, Mickey S; Battista, Vincent; Dubin, Norman H; Pirela-Cruz, Miguel

    2006-03-01

    Several radiologic measurement methods have been described for determining static carpal alignment of the wrist. These include the scapholunate, radiolunate, and capitolunate angles. The triangulation method is an alternative radiologic measurement which we believe is easier to use and more reproducible and reliable than the above mentioned methods. The purpose of this study is to assess the intraobserver reproducibility and interobserver reliability of the triangulation method, scapholunate, radiolunate, and capitolunate angles. Twenty orthopaedic residents and staff at varying levels of training made four radiologic measurements including the scapholunate, radiolunate and capitolunate angles as well as the triangulation method on five different lateral, digitized radiographs of the wrist and forearm in neutral radioulnar deviation. Thirty days after the initial measurements, the participants repeated the four radiologic measurements using the same radiographs. The triangulation method had the best intra-and-interobserver agreement of the four methods tested. This agreement was significantly better than the capitolunate and radiolunate angles. The scapholunate angle had the next best intraobserver reproducibility and interobserver reliability. The triangulation method has the best overall observer agreement when compared to the scapholunate, radiolunate, and capitolunate angles in determining static midcarpal alignment. No comment can be made on the validity of the measurements since there is no radiographic gold standard in determining static carpal alignment.

  19. Automation of metabolic stability studies in microsomes, cytosol and plasma using a 215 Gilson liquid handler.

    PubMed

    Linget, J M; du Vignaud, P

    1999-05-01

    A 215 Gilson liquid handler was used to automate enzymatic incubations using microsomes, cytosol and plasma. The design of automated protocols are described. They were based on the use of 96 deep well plates and on HPLC-based methods for assaying the substrate. The assessment of those protocols was made with comparison between manual and automated incubations, reliability and reproducibility of automated incubations in microsomes and cytosol. Examples of the use of those programs in metabolic studies in drug research, i.e. metabolic screening in microsomes and plasma were shown. Even rapid processes (with disappearance half lives as low as 1 min) can be analysed. This work demonstrates how stability studies can be automated to save time, render experiments involving human biological media less hazardous and may be improve inter-laboratory reproducibility.

  20. A Simulation Study Comparing Procedures for Assessing Individual Educational Growth. Report No. 182.

    ERIC Educational Resources Information Center

    Richards, James M., Jr.

    A computer simulation procedure was developed to reproduce the overall pattern of results obtained in the Educational Testing Service Growth Study. Then simulated data for seven sets of 10,000 to 15,000 cases were analyzed, and findings compared on the basis of correlations between estimated and true growth scores. Findings showed that growth was…

  1. Long-term reproducibility of phantom signal intensities in nonuniformity corrected STIR-MRI examinations of skeletal muscle.

    PubMed

    Viddeleer, Alain R; Sijens, Paul E; van Ooijen, Peter M A; Kuypers, Paul D L; Hovius, Steven E R; Oudkerk, Matthijs

    2009-08-01

    Nerve regeneration could be monitored by comparing MRI image intensities in time, as denervated muscles display increased signal intensity in STIR sequences. In this study long-term reproducibility of STIR image intensity was assessed under clinical conditions and the required image intensity nonuniformity correction was improved by using phantom scans obtained at multiple positions. Three-dimensional image intensity nonuniformity was investigated in phantom scans. Next, over a three-year period, 190 clinical STIR hand scans were obtained using a standardized acquisition protocol, and corrected for intensity nonuniformity by using the results of phantom scanning. The results of correction with 1, 3, and 11 phantom scans were compared. The image intensities in calibration tubes close to the hands were measured every time to determine the reproducibility of our method. With calibration, the reproducibility of STIR image intensity improved from 7.8 to 6.4%. Image intensity nonuniformity correction with 11 phantom scans gave significantly better results than correction with 1 or 3 scans. The image intensities in clinical STIR images acquired at different times can be compared directly, provided that the acquisition protocol is standardized and that nonuniformity correction is applied. Nonuniformity correction is preferably based on multiple phantom scans.

  2. Molecular imaging using light-absorbing imaging agents and a clinical optical breast imaging system--a phantom study.

    PubMed

    van de Ven, Stephanie M W Y; Mincu, Niculae; Brunette, Jean; Ma, Guobin; Khayat, Mario; Ikeda, Debra M; Gambhir, Sanjiv S

    2011-04-01

    The aim of the study was to determine the feasibility of using a clinical optical breast scanner with molecular imaging strategies based on modulating light transmission. Different concentrations of single-walled carbon nanotubes (SWNT; 0.8-20.0 nM) and black hole quencher-3 (BHQ-3; 2.0-32.0 µM) were studied in specifically designed phantoms (200-1,570 mm(3)) with a clinical optical breast scanner using four wavelengths. Each phantom was placed in the scanner tank filled with optical matching medium. Background scans were compared to absorption scans, and reproducibility was assessed. All SWNT phantoms were detected at four wavelengths, with best results at 684 nm. Higher concentrations (≥8.0 µM) were needed for BHQ-3 detection, with the largest contrast at 684 nm. The optical absorption signal was dependent on phantom size and concentration. Reproducibility was excellent (intraclass correlation 0.93-0.98). Nanomolar concentrations of SWNT and micromolar concentrations of BHQ-3 in phantoms were reproducibly detected, showing the potential of light absorbers, with appropriate targeting ligands, as molecular imaging agents for clinical optical breast imaging.

  3. A UK NEQAS ICC and ISH multicentre study using the Kreatech Poseidon HER2 FISH probe: intersite variation can be rigorously controlled using FISH.

    PubMed

    Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith

    2010-02-01

    To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.

  4. Evaluation of questionnaire-based information on previous physical work loads. Stockholm MUSIC 1 Study Group. Musculoskeletal Intervention Center.

    PubMed

    Torgén, M; Winkel, J; Alfredsson, L; Kilbom, A

    1999-06-01

    The principal aim of the present study was to evaluate questionnaire-based information on past physical work loads (6-year recall). Effects of memory difficulties on reproducibility were evaluated for 82 subjects by comparing previously reported results on current work loads (test-retest procedure) with the same items recalled 6 years later. Validity was assessed by comparing self-reports in 1995, regarding work loads in 1989, with worksite measurements performed in 1989. Six-year reproducibility, calculated as weighted kappa coefficients (k(w)), varied between 0.36 and 0.86, with the highest values for proportion of the workday spent sitting and for perceived general exertion and the lowest values for trunk and neck flexion. The six-year reproducibility results were similar to previously reported test-retest results for these items; this finding indicates that memory difficulties was a minor problem. The validity of the questionnaire responses, expressed as rank correlations (r(s)) between the questionnaire responses and workplace measurements, varied between -0.16 and 0.78. The highest values were obtained for the items sitting and repetitive work, and the lowest and "unacceptable" values were for head rotation and neck flexion. Misclassification of exposure did not appear to be differential with regard to musculoskeletal symptom status, as judged by the calculated risk estimates. The validity of some of these self-administered questionnaire items appears sufficient for a crude assessment of physical work loads in the past in epidemiologic studies of the general population with predominantly low levels of exposure.

  5. Polarisation-sensitive OCT is useful for evaluating retinal pigment epithelial lesions in patients with neovascular AMD.

    PubMed

    Schütze, Christopher; Teleky, Katharina; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2016-03-01

    To examine the reproducibility of lesion dimensions of the retinal pigment epithelium (RPE) in neovascular age-related macular degeneration (AMD) with polarisation-sensitive optical coherence tomography (PS-OCT), specifically imaging the RPE. Twenty-six patients (28 eyes) with neovascular AMD were included in this study, and examined by a PS-OCT prototype. Each patient was scanned five times at a 1-day visit. The PS-OCT B-scan located closest to the macular centre presenting with RPE atrophy was identified, and the longitudinal diameter of the lesion was quantified manually using AutoCAD 2008. This procedure was followed for the identical B-scan position in all five scans per eye and patient. Reproducibility of qualitative changes in PS-OCT was evaluated. Interobserver variability was assessed. Results were compared with intensity-based spectral-domain OCT (SD-OCT) imaging. Mean variability of all atrophy lesion dimensions was 0.10 mm (SD±=0.06 mm). Coefficient of variation (SD±/mean) was 0.06 on average (SD±=0.03). Interobserver variability assessment showed a mean difference of 0.02 mm across all patients regarding RPE lesion size evaluation (paired t test: p=0.38). Spearman correlation coefficient was r=0.98, p<0.001. Results revealed a good overall reproducibility of ∼90%. PS-OCT specifically detected the RPE in all eyes compared with conventional intensity-based SD-OCT that was not capable to clearly identify RPE atrophy in 25 eyes (89.3%, p<0.01). PS-OCT offers good reproducibility of RPE atrophy assessment in neovascular AMD, and may be suitable for precise RPE evaluation in clinical practice. PS-OCT unambiguously identifies RPE changes in choroidal neovascularisation compared with intensity-based SD-OCT that does not identify the RPE status reliably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Cross-cultural adaptation and validation of the neonatal/infant Braden Q risk assessment scale.

    PubMed

    de Lima, Edson Luiz; de Brito, Maria José Azevedo; de Souza, Diba Maria Sebba Tosta; Salomé, Geraldo Magela; Ferreira, Lydia Masako

    2016-02-01

    To translate into Brazilian Portuguese and cross-culturally adapt the Neonatal/Infant Braden Q Risk Assessment Scale (Neonatal/Infant Braden Q Scale), and test the psychometric properties, reproducibility and validity of the instrument. There is a lack of studies on the development of pressure ulcers in children, especially in neonates. Thirty professionals participated in the cross-cultural adaptation of the Brazilian-Portuguese version of the scale. Fifty neonates of both sexes were assessed between July 2013 and June 2014. Reliability and reproducibility were tested in 20 neonates and construct validity was measured by correlating the Neonatal/Infant Braden Q Scale with the Braden Q Risk Assessment Scale (Braden Q Scale). Discriminant validity was assessed by comparing the scores of neonates with and without ulcers. The scale showed inter-rater reliability (ICC = 0.98; P < 0.001) and intra-rater reliability (ICC = 0.79; P < 0.001). A strong correlation was found between the Neonatal/Infant Braden Q Scale and Braden Q Scale (r = 0.96; P < 0.001). The cross-culturally adapted Brazilian version of the Neonatal/Infant Braden Q Scale is a reliable instrument, showing face, content and construct validity. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  7. Within-person reproducibility and sensitivity to dietary change of C15:0 and C17:0 levels in dried blood spots: Data from the European Food4Me Study.

    PubMed

    Albani, Viviana; Celis-Morales, Carlos; O'Donovan, Clare B; Walsh, Marianne C; Woolhead, Clara; Forster, Hannah; Fallaize, Rosalind; Macready, Anna L; Marsaux, Cyril F M; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Kolossa, Silvia; Mavrogianni, Christina; Lambrinou, Christina P; Moschonis, George; Godlewska, Magdalena; Surwillo, Agnieszka; Traczyk, Iwona; Gundersen, Thomas E; Drevon, Christian A; Daniel, Hannelore; Manios, Yannis; Martinez, J Alfredo; Saris, Wim H M; Lovegrove, Julie A; Gibney, Michael J; Gibney, Eileen R; Mathers, John C; Adamson, Ashley J; Brennan, Lorraine

    2017-10-01

    Previous work highlighted the potential of odd-chain length saturated fatty acids as potential markers of dairy intake. The aim of this study was to assess the reproducibility of these biomarkers and their sensitivity to changes in dairy intake. Fatty acid profiles and dietary intakes from food frequency questionnaires (FFQs) were measured three times over six months in the Food4Me Study. Reproducibility was explored through intra-class correlation coefficients (ICCs) and within-subject coefficients of variation (WCV). Sensitivity to changes in diet was examined using regression analysis. C15:0 blood levels showed high correlation over time (ICC: 0.62, 95% CI: 0.57, 0.68), however, the ICC for C17:0 was much lower (ICC: 0.32, 95% CI: 0.28, 0.46). The WCV for C15:0 was 16.6% and that for C17:0 was 14.6%. There were significant associations between changes in intakes of total dairy, high-fat dairy, cheese and butter and C15:0; and change in intakes of high-fat dairy and cream and C17:0. Results provide evidence of reproducibility of C15:0 levels over time and sensitivity to change in intake of high-fat dairy products with results comparable to the well-established biomarker of fish intake (EPA+DHA). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Comet assay in reconstructed 3D human epidermal skin models--investigation of intra- and inter-laboratory reproducibility with coded chemicals.

    PubMed

    Reus, Astrid A; Reisinger, Kerstin; Downs, Thomas R; Carr, Gregory J; Zeller, Andreas; Corvi, Raffaella; Krul, Cyrille A M; Pfuhler, Stefan

    2013-11-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure.

  9. Reproducibility of ad libitum energy intake with the use of a computerized vending machine system123

    PubMed Central

    Votruba, Susanne B; Franks, Paul W; Krakoff, Jonathan; Salbe, Arline D

    2010-01-01

    Background: Accurate assessment of energy intake is difficult but critical for the evaluation of eating behavior and intervention effects. Consequently, methods to assess ad libitum energy intake under controlled conditions have been developed. Objective: Our objective was to evaluate the reproducibility of ad libitum energy intake with the use of a computerized vending machine system. Design: Twelve individuals (mean ± SD: 36 ± 8 y old; 41 ± 8% body fat) consumed a weight-maintaining diet for 3 d; subsequently, they self-selected all food with the use of a computerized vending machine system for an additional 3 d. Mean daily energy intake was calculated from the actual weight of foods consumed and expressed as a percentage of weight-maintenance energy needs (%WMEN). Subjects repeated the study multiple times during 2 y. The within-person reproducibility of energy intake was determined through the calculation of the intraclass correlation coefficients (ICCs) between visits. Results: Daily energy intake for all subjects was 5020 ± 1753 kcal during visit 1 and 4855 ± 1615 kcal during visit 2. There were no significant associations between energy intake and body weight, body mass index, or percentage body fat while subjects used the vending machines, which indicates that intake was not driven by body size or need. Despite overconsumption (%WMEN = 181 ± 57%), the reproducibility of intake between visits, whether expressed as daily energy intake (ICC = 0.90), %WMEN (ICC = 0.86), weight of food consumed (ICC = 0.87), or fat intake (g/d; ICC = 0.87), was highly significant (P < 0.0001). Conclusion: Although ad libitum energy intake exceeded %WMEN, the within-person reliability of this intake across multiple visits was high, which makes this a reproducible method for the measurement of ad libitum intake in subjects who reside in a research unit. This trial was registered at clinicaltrials.gov as NCT00342732. PMID:19923376

  10. Comet assay in reconstructed 3D human epidermal skin models—investigation of intra- and inter-laboratory reproducibility with coded chemicals

    PubMed Central

    Pfuhler, Stefan

    2013-01-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure. PMID:24150594

  11. Between and within laboratory reliability of mouse behaviour recorded in home-cage and open-field.

    PubMed

    Robinson, Lianne; Spruijt, Berry; Riedel, Gernot

    2018-04-15

    Reproducibility of behavioural findings between laboratories is difficult due to behaviour being sensitive to environmental factors and interactions with genetics. The objective of this study was to investigate reproducibility of behavioural data between laboratories using the PhenoTyper home cage observation system and within laboratory reproducibility using different lighting regimes. The ambulatory activity of C57BL/6 and DBA/2 mice was tested in PhenoTypers in two laboratories under near identical housing and testing conditions (Exp. 1). Additionally activity and anxiety were also assessed in the open-field test. Furthermore, testing in either a normal or inverted light/dark cycle was used to determine effects of lighting regime in a within-laboratory comparison in Aberdeen (Exp. 2). Using the PhenoTyper similar circadian rhythms were observed across laboratories. Higher levels of baseline and novelty-induced activity were evident in Aberdeen compared to Utrecht although strain differences were consistent between laboratories. Open field activity was also similar across laboratories whereas strain differences in anxiety were different. Within laboratory analysis of different lighting regimes revealed that behaviour of the mice was sensitive to changes in lighting. Utilisation of a home cage observation system facilitates the reproducibility of activity but not anxiety-related behaviours across laboratories by eliminating environmental factors known to influence reproducibility in standard behavioural tests. Standardisation of housing/test conditions resulted in reproducibility of home cage and open field activity but not anxiety-related phenotypes across laboratories with some behaviours more sensitive to environmental factors. Environmental factors include lighting and time of day. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners

    PubMed Central

    2013-01-01

    Background Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (λ), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by ΔR1myocardium phantom/ΔR1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and λ across field strength, scanners, and protocols. Results Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not λ accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for λ vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision. PMID:23890156

  13. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing.

    PubMed

    Busquet, François; Strecker, Ruben; Rawlings, Jane M; Belanger, Scott E; Braunbeck, Thomas; Carr, Gregory J; Cenijn, Peter; Fochtman, Przemyslaw; Gourmelon, Anne; Hübler, Nicole; Kleensang, André; Knöbel, Melanie; Kussatz, Carola; Legler, Juliette; Lillicrap, Adam; Martínez-Jerónimo, Fernando; Polleichtner, Christian; Rzodeczko, Helena; Salinas, Edward; Schneider, Katharina E; Scholz, Stefan; van den Brandhof, Evert-Jan; van der Ven, Leo T M; Walter-Rohde, Susanne; Weigt, Stefan; Witters, Hilda; Halder, Marlies

    2014-08-01

    The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were analytically confirmed for 11 chemicals. Newly fertilised zebrafish eggs (20/concentration and control) were exposed for 96h to chemicals. Four apical endpoints were recorded daily as indicators of acute lethality: coagulation of the embryo, lack of somite formation, non-detachment of the tail bud from the yolk sac and lack of heartbeat. Results (LC50 values for 48/96h exposure) show that the ZFET is a robust method with a good intra- and inter-laboratory reproducibility (CV<30%) for most chemicals and laboratories. The reproducibility was lower (CV>30%) for some very toxic or volatile chemicals, and chemicals tested close to their limit of solubility. The ZFET is now available as OECD Test Guideline 236. Considering the high predictive capacity of the ZFET demonstrated by Belanger et al. (2013) in their retrospective analysis of acute fish toxicity and fish embryo acute toxicity data, the ZFET is ready to be considered for acute fish toxicity for regulatory purposes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Validity and reproducibility of a food frequency questionnaire (FFQ) for dietary assessment in Malay adolescents in Malaysia.

    PubMed

    Nurul-Fadhilah, Abdullah; Teo, Pey Sze; Foo, Leng Huat

    2012-01-01

    Food frequency questionnaire (FFQ) must be tailored to the target populations because dietary habits vary within the populations due to differences in cultural and lifestyles practices. Limited information is available to assess the validity of FFQ used among Malaysian adolescents. To construct the validity and reproducibility of a newly developed FFQ in assessing habitual nutrients intake over the past year of 170 Malay adolescent boys and girls in Kelantan, Malaysia. The FFQ that consisted of 124 food items was assessed, whereas three days of 24-hours dietary recalls (DR) was administered as the standard criteria method. Estimated mean intake for most nutrients assessed by the FFQ were higher as compared to the three DRs (p<0.05). Pearson correlation coefficients for energy-adjusted nutrients intake between both methods were ranged from 0.22 (zinc) to 0.68 (calcium) with a median r-value of 0.43. The cross classification of quartile analysis showed that most nutrients were classified into the same or adjacent quartiles (median=52.7%). For the reproducibility of FFQ, the correlation of nutrients ranged from 0.43 for carotene to 0.86 for total fat intake (median=0.67), after adjusting for total energy intake. The newly developed dietary FFQ is a relatively good and valid tool in assessing habitual nutrients intake for the past year among Malay adolescents in Malaysia.

  15. Evaluation of normality and reproducibility parameters of scintigraphy with (99m)Tc-MAA in the diagnosis of intrapulmonary vascular dilatations.

    PubMed

    de Queirós, Andréa Simone Siqueira; Brandão, Simone Cristina Soares; Macedo, Liana Gonçalves; Ourem, Maira Souto; Mota, Vitor Gomes; Leite, Luiz Arthur Calheiros; Lopes, Edmundo Pessoa Almeida; Domingues, Ana Lúcia Coutinho

    2015-01-01

    The formation of intrapulmonary vascular dilations (IPVD) is the key event for the onset of hepatopulmonary syndrome, vascular changes secondary to portal hypertension that leads to hypoxemia. The diagnosis of IPVD can be made by contrasted transthoracic echocardiography or scintigraphy with technetium-macroaggregated albumin-((99m)Tc-MAA)-that is a sensitive and specific diagnostic method and quantifies the IPVD magnitude. However, its procedure and diagnostic indices are not yet standardized and well defined in health services. The aims of this study were to define normality values and evaluate the inter- and intra-observer reproducibility degree of diagnostic indexes of IPVD through (99m)Tc-MAA scintigraphy. Cross-sectional study was conducted at the Clinical Hospital, Federal University of Pernambuco (HC-UFPE) between July and December 2012. Fifteen patients with hepatosplenic schistosomiasis and nine patients without liver or heart disease (control group) were assessed. After clinical assessment, ultrasound and echocardiography, patients underwent (99m)Tc-MAA scintigraphy, and a relative brain uptake value exceeding 6 % or systemic uptake value exceeding 11 % was considered diagnostic of IPVD. Each assessment was performed by two independent observers. To analyze the results of the normal group, the nonparametric Bootsptrap method simulation model combined with the Monte Carlo method was used and to analyze inter- and intra-observer reproducibility indexes, the kappa and intra-class correlation coefficient were used. In normal subjects, the average brain uptake of (99m)Tc-MAA was 7.9 ± 0.01 % and systemic uptake was 12.4 ± 0.03 %, with low dispersal rates for both measures. The intra-observer agreement was 100 %, with kappa index of 1.0 (p < 0.0001), suggesting a perfect agreement. The inter-observer agreement was also 100 % (kappa = 1.0, p < 0.0001) for brain uptake; however, systemic uptake showed kappa = 0.25 (p = 0.07), which features tolerable concordance. The intra-class correlation was excellent for both uptake indexes. The normality values were slightly higher than those reported in studies from other countries. The demographic characteristics of the Brazilian population, the small number of patients or different methodologies can be the causes of such differences. (99m)Tc-MAA scintigraphy showed excellent reproducibility.

  16. Gross Motor Skill Acquisition in Adolescents with Down Syndrome

    ERIC Educational Resources Information Center

    Meegan, Sarah; Maraj, Brian K. V.; Weeks, Daniel; Chua, Romeo

    2006-01-01

    The purpose of this study was to assess whether verbal-motor performances deficits exhibited by individuals with Down syndrome limited their ability to acquire gross motor skills when given visual and verbal instruction together and then transferred to either a visual or verbal instructional mode to reproduce the movement. Nine individuals with…

  17. A Screening Matrix for an Initial Line of Inquiry

    ERIC Educational Resources Information Center

    Nordness, Philip D.; Swain, Kristine D.; Haverkost, Ann

    2012-01-01

    The Screening for Understanding: Initial Line of Inquiry was designed to be used in conjunction with the child study team planning process for dealing with continuous problem behaviors prior to conducting a formal functional behavioral assessment. To conduct the initial line of inquiry a one-page reproducible screening matrix was used during child…

  18. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    PubMed

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p<0,001): 18.73° (SD = 6.42), -3,25° (SD = 5.51) and 6,89° (SD = 4,41) respectively for V-pattern, A- pattern and normal subjects. Neither observers (F = 0,2028 p = 0,9369) nor time between 1st and 2nd NMFP (F = 0,6312 p = 0,4271) seem to influence the measure of disc-foveal angle. The evaluation of disc-foveal angle was very reproducible between observers (ICC>0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  19. Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance.

    PubMed

    D'Errico, Luigia; Lamacie, Mariana M; Jimenez Juan, Laura; Deva, Djeven; Wald, Rachel M; Ley, Sebastian; Hanneman, Kate; Thavendiranathan, Paaladinesh; Wintersperger, Bernd J

    2016-09-22

    Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student's t-test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm; P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL; P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[-9.5 %,10.3 %] and 2.1 %[-12.3 %,16.4 %] for short-axis and 1.1 %[-7.3 %,9.4 %] and 0.8 %[-16.0 %,17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395-0.824), intra-observer variability (p = 0.726-0.862) or inter-observer variability (p = 0.447-0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769-0.986 vs. 0.625-0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment.

  20. Quantitative susceptibility mapping of human brain at 3T: a multisite reproducibility study.

    PubMed

    Lin, P-Y; Chao, T-C; Wu, M-L

    2015-03-01

    Quantitative susceptibility mapping of the human brain has demonstrated strong potential in examining iron deposition, which may help in investigating possible brain pathology. This study assesses the reproducibility of quantitative susceptibility mapping across different imaging sites. In this study, the susceptibility values of 5 regions of interest in the human brain were measured on 9 healthy subjects following calibration by using phantom experiments. Each of the subjects was imaged 5 times on 1 scanner with the same procedure repeated on 3 different 3T systems so that both within-site and cross-site quantitative susceptibility mapping precision levels could be assessed. Two quantitative susceptibility mapping algorithms, similar in principle, one by using iterative regularization (iterative quantitative susceptibility mapping) and the other with analytic optimal solutions (deterministic quantitative susceptibility mapping), were implemented, and their performances were compared. Results show that while deterministic quantitative susceptibility mapping had nearly 700 times faster computation speed, residual streaking artifacts seem to be more prominent compared with iterative quantitative susceptibility mapping. With quantitative susceptibility mapping, the putamen, globus pallidus, and caudate nucleus showed smaller imprecision on the order of 0.005 ppm, whereas the red nucleus and substantia nigra, closer to the skull base, had a somewhat larger imprecision of approximately 0.01 ppm. Cross-site errors were not significantly larger than within-site errors. Possible sources of estimation errors are discussed. The reproducibility of quantitative susceptibility mapping in the human brain in vivo is regionally dependent, and the precision levels achieved with quantitative susceptibility mapping should allow longitudinal and multisite studies such as aging-related changes in brain tissue magnetic susceptibility. © 2015 by American Journal of Neuroradiology.

  1. Cosmetics Europe multi-laboratory pre-validation of the SkinEthic™ reconstituted human corneal epithelium test method for the prediction of eye irritation.

    PubMed

    Alépée, N; Bessou-Touya, S; Cotovio, J; de Smedt, A; de Wever, B; Faller, C; Jones, P; Le Varlet, B; Marrec-Fairley, M; Pfannenbecker, U; Tailhardat, M; van Goethem, F; McNamee, P

    2013-08-01

    Cosmetics Europe, The Personal Care Association, known as Colipa before 2012, conducted a program of technology transfer and assessment of Within/Between Laboratory (WLV/BLV) reproducibility of the SkinEthic™ Reconstituted Human Corneal Epithelium (HCE) as one of two human reconstructed tissue eye irritation test methods. The SkinEthic™ HCE test method involves two exposure time treatment procedures - one for short time exposure (10 min - SE) and the other for long time exposure (60 min - LE) of tissues to test substance. This paper describes pre-validation studies of the SkinEthic™ HCE test method (SE and LE protocols) as well as the Eye Peptide Reactivity Assay (EPRA). In the SE WLV study, 30 substances were evaluated. A consistent outcome with respect to viability measurement across all runs was observed with all substances showing an SD of less than 18%. In the LE WLV study, 44 out of 45 substances were consistently classified. These data demonstrated a high level of reproducibility within laboratory for both the SE and LE treatment procedures. For the LE BLV, 19 out of 20 substances were consistently classified between the three laboratories, again demonstrating a high level of reproducibility between laboratories. The results for EPRA WLV and BLV studies demonstrated that all substances analysed were categorised similarly and that the method is reproducible. The SkinEthic™ HCE test method entered into the experimental phase of a formal ECVAM validation program in 2010. Copyright © 2013. Published by Elsevier Ltd.

  2. Current Strategies for Quantitating Fibrosis in Liver Biopsy

    PubMed Central

    Wang, Yan; Hou, Jin-Lin

    2015-01-01

    Objective: The present mini-review updated the progress in methodologies based on using liver biopsy. Data Sources: Articles for study of liver fibrosis, liver biopsy or fibrosis assessment published on high impact peer review journals from 1980 to 2014. Study Selection: Key articles were selected mainly according to their levels of relevance to this topic and citations. Results: With the recently mounting progress in chronic liver disease therapeutics, comes by a pressing need for precise, accurate, and dynamic assessment of hepatic fibrosis and cirrhosis in individual patients. Histopathological information is recognized as the most valuable data for fibrosis assessment. Conventional histology categorical systems describe the changes of fibrosis patterns in liver tissue; but the simplified ordinal digits assigned by these systems cannot reflect the fibrosis dynamics with sufficient precision and reproducibility. Morphometric assessment by computer assist digital image analysis, such as collagen proportionate area (CPA), detects change of fibrosis amount in tissue section in a continuous variable, and has shown its independent diagnostic value for assessment of advanced or late-stage of fibrosis. Due to its evident sensitivity to sampling variances, morphometric measurement is feasible to be taken as a reliable statistical parameter for the study of a large cohort. Combining state-of-art imaging technology and fundamental principle in Tissue Engineering, structure-based quantitation was recently initiated with a novel proof-of-concept tool, qFibrosis. qFibrosis showed not only the superior performance to CPA in accurately and reproducibly differentiating adjacent stages of fibrosis, but also the possibility for facilitating analysis of fibrotic regression and cirrhosis sub-staging. Conclusions: With input from multidisciplinary innovation, liver biopsy assessment as a new “gold standard” is anticipated to substantially support the accelerated progress of Hepatology medicine. PMID:25591571

  3. Digital image analysis: improving accuracy and reproducibility of radiographic measurement.

    PubMed

    Bould, M; Barnard, S; Learmonth, I D; Cunningham, J L; Hardy, J R

    1999-07-01

    To assess the accuracy and reproducibility of a digital image analyser and the human eye, in measuring radiographic dimensions. We experimentally compared radiographic measurement using either an image analyser system or the human eye with digital caliper. The assessment of total hip arthroplasty wear from radiographs relies on both the accuracy of radiographic images and the accuracy of radiographic measurement. Radiographs were taken of a slip gauge (30+/-0.00036 mm) and slip gauge with a femoral stem. The projected dimensions of the radiographic images were calculated by trigonometry. The radiographic dimensions were then measured by blinded observers using both techniques. For a single radiograph, the human eye was accurate to 0.26 mm and reproducible to +/-0.1 mm. In comparison the digital image analyser system was accurate to 0.01 mm with a reproducibility of +/-0.08 mm. In an arthroplasty model, where the dimensions of an object were corrected for magnification by the known dimensions of a femoral head, the human eye was accurate to 0.19 mm, whereas the image analyser system was accurate to 0.04 mm. The digital image analysis system is up to 20 times more accurate than the human eye, and in an arthroplasty model the accuracy of measurement increases four-fold. We believe such image analysis may allow more accurate and reproducible measurement of wear from standard follow-up radiographs.

  4. Comparison of non-invasive methods for the assessment of haemodynamic drug effects in healthy male and female volunteers: sex differences in cardiovascular responsiveness.

    PubMed Central

    Wolzt, M; Schmetterer, L; Rheinberger, A; Salomon, A; Unfried, C; Breiteneder, H; Ehringer, H; Eichler, H G; Fercher, A F

    1995-01-01

    1. The study was performed to determine the sensitivity and short-term and day-to-day variability of a novel technique based on laser interferometry of ocular fundus pulsations and of non-invasive methods for the quantification of haemodynamic drug effects. An additional aim was to assess sex differences in haemodynamic responsiveness to cardiovascular drugs in male and female healthy volunteers. 2. Ten males and nine females (age range 20-33 years) were studied in a double-blind, randomized, cross-over trial. Simultaneous measurements from systemic haemodynamics, laser interferometry of ocular fundus pulsations, systolic time intervals from mechanocardiography, a/b ratio from oxymetric fingerplethysmography and Doppler sonography of the radial artery were used to describe the haemodynamic effects of cumulative, stepwise increasing intravenous doses of phenylephrine, isoprenaline, sodium nitroprusside and of placebo. 3. Laser interferometry detected the isoprenaline-effects at the lowest dose level of 0.1 micrograms min-1 with a high signal-to-noise ratio. The reproducibility of measurements under baseline was high, no changes were observed after systemically effective doses of phenylephrine or sodium nitroprusside. Systolic time intervals were sensitive and specific for isoprenaline-induced effects, PEP and QS2c-measurements had high reproducibility. Fingerplethysmography proved a sensitive measurement for the detection of the vasodilating effects of sodium nitroprusside, but was not specific, and showed low reproducibility. Measurements from Doppler sonography had lower reproducibility and sensitivity compared with the other applied methods. 4. There was a significant sex difference for several of the haemodynamic parameters under baseline conditions; however, the responsiveness to the drugs under study was not different, when drug effects were expressed as %-change from the baseline. 5. Laser interferometry is a valuable non-invasive, highly sensitive and specific approach for the detection of pulse pressure changes. A battery of non-invasive tests appears useful for the characterization of cardiovascular drugs. Gender differences may not pose a relevant problem for the study of acute haemodynamic effects of cardiovascular drugs. Images Figure 1 PMID:7640140

  5. Measurement properties of continuous text reading performance tests.

    PubMed

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  6. Automated volumetric evaluation of stereoscopic disc photography

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S

    2010-01-01

    PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996

  7. The modified patient enablement instrument: a Portuguese cross-cultural adaptation, validity and reliability study.

    PubMed

    Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime

    2017-01-12

    Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in Portugal. Further studies are needed to confirm its responsiveness.

  8. Clinical assessment of external rotation for the diagnosis of anterior shoulder hyperlaxity.

    PubMed

    Ropars, M; Fournier, A; Campillo, B; Bonan, I; Delamarche, P; Crétual, A; Thomazeau, H

    2010-12-01

    The aim of this study was to evaluate two methods of clinical assessment for external rotation of the shoulder to optimise the diagnosis of hyperlaxity in patients being selected for surgery for stabilisation of chronic anterior instability. External rotation was evaluated in 70 healthy student volunteers by two examiners (intertester study) using two methods of assessment at 15-day intervals (intratester study). The first method used was the protocol described for the Instability Severity Index Score (ISIS). In this case, the subject was evaluated in the sitting position, bilaterally with passive range of motion movements. The shoulder was considered hyperlax if ER1 was greater than 85°. With the second, so-called "elbow on the table" (EOT) method, the subject was evaluated in the decubitus dorsal position, unilaterally with passive range of motion. The subject was considered to be hyperlax if ER1 was greater than 90°. Kappa values for intra- and intertester agreement with the ISIS method were average, while they were satisfactory with the intraclass coefficient (ICC). Kappa values for inter- and intratester agreement with the EOT method were average and good, respectively. This tendency was confirmed by the ICC which went from good to excellent for the two examiners in both series of measurements using the EOT method, showing better reproducibility with this method. Our study confirms that the most reproducible method for assessing external rotation is obtained by unilateral assessment of the patient in the decubitus dorsal position, with passive range of motion. An ER1 of 90° is the necessary threshold for hyperlaxity because of elbow retropulsion with this method, which provides immediate and visual evaluation and eliminates the necessity of goniometry. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  9. Reproducibility in Natural Language Processing: A Case Study of Two R Libraries for Mining PubMed/MEDLINE.

    PubMed

    Cohen, K Bretonnel; Xia, Jingbo; Roeder, Christophe; Hunter, Lawrence E

    2016-05-01

    There is currently a crisis in science related to highly publicized failures to reproduce large numbers of published studies. The current work proposes, by way of case studies, a methodology for moving the study of reproducibility in computational work to a full stage beyond that of earlier work. Specifically, it presents a case study in attempting to reproduce the reports of two R libraries for doing text mining of the PubMed/MEDLINE repository of scientific publications. The main findings are that a rational paradigm for reproduction of natural language processing papers can be established; the advertised functionality was difficult, but not impossible, to reproduce; and reproducibility studies can produce additional insights into the functioning of the published system. Additionally, the work on reproducibility lead to the production of novel user-centered documentation that has been accessed 260 times since its publication-an average of once a day per library.

  10. Comparative study of solution-phase and vapor-phase deposition of aminosilanes on silicon dioxide surfaces.

    PubMed

    Yadav, Amrita R; Sriram, Rashmi; Carter, Jared A; Miller, Benjamin L

    2014-02-01

    The uniformity of aminosilane layers typically used for the modification of hydroxyl bearing surfaces such as silicon dioxide is critical for a wide variety of applications, including biosensors. However, in spite of many studies that have been undertaken on surface silanization, there remains a paucity of easy-to-implement deposition methods reproducibly yielding smooth aminosilane monolayers. In this study, solution- and vapor-phase deposition methods for three aminoalkoxysilanes differing in the number of reactive groups (3-aminopropyl triethoxysilane (APTES), 3-aminopropyl methyl diethoxysilane (APMDES) and 3-aminopropyl dimethyl ethoxysilane (APDMES)) were assessed with the aim of identifying methods that yield highly uniform and reproducible silane layers that are resistant to minor procedural variations. Silane film quality was characterized based on measured thickness, hydrophilicity and surface roughness. Additionally, hydrolytic stability of the films was assessed via these thickness and contact angle values following desorption in water. We found that two simple solution-phase methods, an aqueous deposition of APTES and a toluene based deposition of APDMES, yielded high quality silane layers that exhibit comparable characteristics to those deposited via vapor-phase methods. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Performance analysis of the OneTouch UltraVue blood glucose monitoring system.

    PubMed

    Chang, Anna; Orth, Alice; Le, Bryan; Menchavez, Perla; Miller, Lupe

    2009-09-01

    OneTouch UltraVue is a new meter for self-monitoring of blood glucose that includes a color display, used-strip ejector, and no-button interface. The system uses an electrochemical biosensor technology based on glucose oxidase chemistry to detect glucose concentrations from 20 to 600 mg/dl (1.1 to 33.3 mmol/liter). Accuracy and reproducibility were evaluated over a wide range of glucose concentrations according to standard criteria. Clinical accuracy was assessed by health care providers (HCPs) in two studies and by diabetes patients in the second study. Reference glucose levels were determined by a YSI 2300 analyzer. Same-day reproducibility and day-to-day reproducibility were also evaluated. In the accuracy studies, 99.7% and 98.7% of tests by HCPs and 97.0% of tests by patients were within +/-15 mg/dl (+/-0.8 mmol/liter) of the YSI reference for blood glucose <75 mg/dl (<4.2 mmol/liter), and within +/-20% for blood glucose > or =75 mg/dl (> or =4.2 mmol/liter), respectively. Consensus error grid analysis showed that 99.7% and 95.3% of tests by HCPs and 97.0% of tests by patients fell within zone A (i.e., has no effect on clinical action); all other results were in zone B (i.e., altered clinical action, little or no effect on clinical outcome). In the reproducibility studies, the standard deviation was <1.5 mg/dl (<0.1 mmol/liter) for glucose concentrations <100 mg/dl (<5.6 mmol/liter), and the coefficient of variation was <2% for concentrations > or = 100 mg/dl (> or =5.6 mmol/liter). OneTouch UltraVue meets standard acceptability criteria for accuracy and reproducibility across a wide range of glucose concentrations. Its simple interface and lack of contact with used strips make it a viable option for older patients and their caregivers. 2009 Diabetes Technology Society.

  12. Performance Analysis of the OneTouch® UltraVue™ Blood Glucose Monitoring System

    PubMed Central

    Chang, Anna; Orth, Alice; Le, Bryan; Menchavez, Perla; Miller, Lupe

    2009-01-01

    Background OneTouch® UltraVue™ is a new meter for self-monitoring of blood glucose that includes a color display, used-strip ejector, and no-button interface. The system uses an electrochemical biosensor technology based on glucose oxidase chemistry to detect glucose concentrations from 20 to 600 mg/dl (1.1 to 33.3 mmol/liter). Methods Accuracy and reproducibility were evaluated over a wide range of glucose concentrations according to standard criteria. Clinical accu-racy was assessed by health care providers (HCPs) in two studies and by diabetes patients in the second study. Reference glucose lev-els were determined by a YSI 2300 analyzer. Same-day reproducibility and day-to-day reproducibility were also evaluated. Results In the accuracy studies, 99.7% and 98.7% of tests by HCPs and 97.0% of tests by patients were within ±15 mg/dl (±0.8 mmol/liter) of the YSI reference for blood glucose <75 mg/dl (<4.2 mmol/liter), and within ±20% for blood glucose ≥75 mg/dl (≥4.2 mmol/liter), respectively. Consensus error grid analysis showed that 99.7% and 95.3% of tests by HCPs and 97.0% of tests by patients fell within zone A (i.e., has no effect on clinical action); all other results were in zone B (i.e., altered clinical action, little or no effect on clini-cal outcome). In the reproducibility studies, the standard deviation was <1.5 mg/dl (<0.1 mmol/liter) for glucose concentra-tions <100 mg/dl (<5.6 mmol/liter), and the coefficient of variation was <2% for concentrations ≥100 mg/dl (≥5.6 mmol/liter). Conclusions OneTouch UltraVue meets standard acceptability criteria for accuracy and reproducibility across a wide range of glucose concentra-tions. Its simple interface and lack of contact with used strips make it a viable option for older patients and their caregivers. PMID:20144431

  13. Validation of World Health Organization Assessment Schedule 2.0 in specialized somatic rehabilitation services in Norway.

    PubMed

    Moen, Vegard Pihl; Drageset, Jorunn; Eide, Geir Egil; Klokkerud, Mari; Gjesdal, Sturla

    2017-02-01

    The World Health Organization Disability Assessment Schedule (WHODAS) 2.0 is a generic instrument to assess disability covering six domains. The purpose of this study was to investigate the potential of the instrument for monitoring disability in specialized somatic rehabilitation by testing reliability, construct validity and responsiveness of WHODAS 2.0, Norwegian version, among patients with various health conditions. For taxonomy, terminology and definitions, the Consensus-based Standards for the Selection of Health Measurement Instruments were followed. Reproducibility was investigated by the intra-class correlation coefficient (ICC) in a randomly selected sample. Internal consistency was assessed by Cronbach's alpha. Construct validity was evaluated by correlations between WHODAS 2.0 and the Medical Outcomes Study 36-item Short Form, and fit of the hypothesized structure using confirmatory factor analysis (CFA). Responsiveness was evaluated in another randomly selected sample by testing a priori formulated hypotheses. Nine hundred seventy patients were included in the study. Reproducibility and responsiveness were evaluated in 53 and 104 patients, respectively. The ICC for the WHODAS 2.0 domains ranged from 0.63 to 0.84 and was 0.87 for total score. Cronbach's alpha for domains ranged from 0.75 to 0.94 and was 0.93 for total score. For construct validity, 6 of 12 expected correlations were confirmed and CFA did not achieve satisfactory fit indices. For responsiveness, 3 of 8 hypotheses were confirmed. The Norwegian version of WHODAS 2.0 showed moderate to satisfactory reliability and moderate validity in rehabilitation patients. However, the present study indicated possible limitations in terms of responsiveness.

  14. T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study.

    PubMed

    Albano, Domenico; Chianca, Vito; Cuocolo, Renato; Bignone, Rodolfo; Ciccia, Francesco; Sconfienza, Luca Maria; Midiri, Massimo; Brunetti, Arturo; Lagalla, Roberto; Galia, Massimo

    2018-04-20

    To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between T2 relaxation times and body mass index (BMI) was tested using the Spearman's rho. Eighty sacroiliac joints of 40 subjects (mean age: 28 ± 4.8 years, range: 20-43; mean BMI: 23.3 ± 3.1, range: 18.9-30) were imaged. The mean T2 values obtained by the senior radiologist in the first series of measurements were 42 ± 4.4 ms, whereas in the second series were 40.7 ± 4.5 ms. The mean T2 values obtained by the radiology resident were 41.1 ± 4.2 ms. Intra-observer reproducibility was 88% (coefficient of repeatability = 3.8; bias = 1.28; p < .001), while inter-observer reproducibility was 86% (4.7; -.88; p < .001). There was significant association between sex and T2 relaxation times (p = .024) and significant inverse correlation between T2 relaxation times and BMI (r = -.340, p = .002). The assessment of T2 relaxation time measurements of sacroiliac joints seems to be highly reproducible at 1.5 T. Further studies could investigate the potential clinical application of this tool in the sacroiliac joints.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, P; Wang, J; Zhong, H

    Purpose: To evaluate the reproducibility of radiomics features by repeating computed tomographic (CT) scans in rectal cancer. To choose stable radiomics features for rectal cancer. Methods: 40 rectal cancer patients were enrolled in this study, each of whom underwent two CT scans within average 8.7 days (5 days to 17 days), before any treatment was delivered. The rectal gross tumor volume (GTV) was distinguished and segmented by an experienced oncologist in both CTs. Totally, more than 2000 radiomics features were defined in this study, which were divided into four groups (I: GLCM, II: GLRLM III: Wavelet GLCM and IV: Waveletmore » GLRLM). For each group, five types of features were extracted (Max slice: features from the largest slice of target images, Max value: features from all slices of target images and choose the maximum value, Min value: minimum value of features for all slices, Average value: average value of features for all slices, Matrix sum: all slices of target images translate into GLCM and GLRLM matrices and superpose all matrices, then extract features from the superposed matrix). Meanwhile a LOG (Laplace of Gauss) filter with different parameters was applied to these images. Concordance correlation coefficients (CCC) and inter-class correlation coefficients (ICC) were calculated to assess the reproducibility. Results: 403 radiomics features were extracted from each type of patients’ medical images. Features of average type are the most reproducible. Different filters have little effect for radiomics features. For the average type features, 253 out of 403 features (62.8%) showed high reproducibility (ICC≥0.8), 133 out of 403 features (33.0%) showed medium reproducibility (0.8≥ICC≥0.5) and 17 out of 403 features (4.2%) showed low reproducibility (ICC≥0.5). Conclusion: The average type radiomics features are the most stable features in rectal cancer. Further analysis of these features of rectal cancer can be warranted for treatment monitoring and prognosis prediction.« less

  16. Reproducibility, Reliability, and Validity of Fuchsin-Based Beads for the Evaluation of Masticatory Performance.

    PubMed

    Sánchez-Ayala, Alfonso; Farias-Neto, Arcelino; Vilanova, Larissa Soares Reis; Costa, Marina Abrantes; Paiva, Ana Clara Soares; Carreiro, Adriana da Fonte Porto; Mestriner-Junior, Wilson

    2016-08-01

    Rehabilitation of masticatory function is inherent to prosthodontics; however, despite the various techniques for evaluating oral comminution, the methodological suitability of these has not been completely studied. The aim of this study was to determine the reproducibility, reliability, and validity of a test food based on fuchsin beads for masticatory function assessment. Masticatory performance was evaluated in 20 dentate subjects (mean age, 23.3 years) using two kinds of test foods and methods: fuchsin beads and ultraviolet-visible spectrophotometry, and silicone cubes and multiple sieving as gold standard. Three examiners conducted five masticatory performance trials with each test food. Reproducibility of the results from both test foods was separately assessed using the intraclass correlation coefficient (ICC). Reliability and validity of fuchsin bead data were measured by comparing the average mean of absolute differences and the measurement means, respectively, regarding silicone cube data using the paired Student's t-test (α = 0.05). Intraexaminer and interexaminer ICC for the fuchsin bead values were 0.65 and 0.76 (p < 0.001), respectively; those for the silicone cubes values were 0.93 and 0.91 (p < 0.001), respectively. Reliability revealed intraexaminer (p < 0.001) and interexaminer (p < 0.05) differences between the average means of absolute differences of each test foods. Validity also showed differences between the measurement means of each test food (p < 0.001). Intra- and interexaminer reproducibility of the test food based on fuchsin beads for evaluation of masticatory performance were good and excellent, respectively; however, the reliability and validity were low, because fuchsin beads do not measure the grinding capacity of masticatory function as silicone cubes do; instead, this test food describes the crushing potential of teeth. Thus, the two kinds of test foods evaluate different properties of masticatory capacity, confirming fushsin beads as a useful tool for this purpose. © 2015 by the American College of Prosthodontists.

  17. Quantitative Assessment of the Sensitivity of Various Commercial Reverse Transcriptases Based on Armored HIV RNA

    PubMed Central

    Okello, John B. A.; Rodriguez, Linda; Poinar, Debi; Bos, Kirsten; Okwi, Andrew L.; Bimenya, Gabriel S.; Sewankambo, Nelson K.; Henry, Kenneth R.; Kuch, Melanie; Poinar, Hendrik N.

    2010-01-01

    Background The in-vitro reverse transcription of RNA to its complementary DNA, catalyzed by the enzyme reverse transcriptase, is the most fundamental step in the quantitative RNA detection in genomic studies. As such, this step should be as analytically sensitive, efficient and reproducible as possible, especially when dealing with degraded or low copy RNA samples. While there are many reverse transcriptases in the market, all claiming to be highly sensitive, there is need for a systematic independent comparison of their applicability in quantification of rare RNA transcripts or low copy RNA, such as those obtained from archival tissues. Methodology/Principal Findings We performed RT-qPCR to assess the sensitivity and reproducibility of 11 commercially available reverse transcriptases in cDNA synthesis from low copy number RNA levels. As target RNA, we used a serially known number of Armored HIV RNA molecules, and observed that 9 enzymes we tested were consistently sensitive to ∼1,000 copies, seven of which were sensitive to ∼100 copies, while only 5 were sensitive to ∼10 RNA template copies across all replicates tested. Despite their demonstrated sensitivity, these five best performing enzymes (Accuscript, HIV-RT, M-MLV, Superscript III and Thermoscript) showed considerable variation in their reproducibility as well as their overall amplification efficiency. Accuscript and Superscript III were the most sensitive and consistent within runs, with Accuscript and Superscript II ranking as the most reproducible enzymes between assays. Conclusions/Significance We therefore recommend the use of Accuscript or Superscript III when dealing with low copy number RNA levels, and suggest purification of the RT reactions prior to downstream applications (eg qPCR) to augment detection. Although the results presented in this study were based on a viral RNA surrogate, and applied to nucleic acid lysates derived from archival formalin-fixed paraffin embedded tissue, their relative performance on RNA obtained from other tissue types may vary, and needs future evaluation. PMID:21085668

  18. Multisite analytic performance studies of a real-time polymerase chain reaction assay for the detection of BRAF V600E mutations in formalin-fixed, paraffin-embedded tissue specimens of malignant melanoma.

    PubMed

    Anderson, Steven; Bloom, Kenneth J; Vallera, Dino U; Rueschoff, Josef; Meldrum, Cliff; Schilling, Robert; Kovach, Barbara; Lee, Ju Ruey-Jiuan; Ochoa, Pam; Langland, Rachel; Halait, Harkanwal; Lawrence, H Jeffrey; Dugan, Michael C

    2012-11-01

    A polymerase chain reaction-based companion diagnostic (cobas 4800 BRAF V600 Mutation Test) was recently approved by the US Food and Drug Administration to select patients with BRAF-mutant metastatic melanoma for treatment with the BRAF inhibitor vemurafenib. (1) To compare the analytic performance of the cobas test to Sanger sequencing by using screening specimens from phase II and phase III trials of vemurafenib, and (2) to assess the reproducibility of the cobas test at different testing sites. Specimens from 477 patients were used to determine positive and negative percent agreements between the cobas test and Sanger sequencing for detecting V600E (1799T>A) mutations. Specimens were evaluated with a massively parallel pyrosequencing method (454) to resolve discordances between polymerase chain reaction and Sanger results. Reproducibility of the cobas test was assessed at 3 sites by using 3 reagent lots and an 8-member panel of melanoma samples. A valid cobas result was obtained for all eligible patients. Sanger sequencing had a failure rate of 9.2% (44 of 477). For the remaining 433 specimens, positive percent agreement was 96.4% (215 of 223) and negative percent agreement, 80% (168 of 210). Among 42 cobas mutation-positive/Sanger V600E-negative specimens, 17 were V600E positive and 24 were V600K positive by 454. The cobas test detected 70% of V600K mutations. In the reproducibility study, a correct interpretation was made for 100% of wild-type specimens and specimens with greater than 5% mutant alleles; V600E mutations were detected in 90% of specimens with less than 5% mutant alleles. The cobas test (1) had a lower assay failure rate than that of Sanger, (2) was more sensitive in detecting V600E mutations, (3) detected most V600K mutations, and (4) was highly reproducible.

  19. Comparative Validity and Reproducibility Study of Various Landmark-Oriented Reference Planes in 3-Dimensional Computed Tomographic Analysis for Patients Receiving Orthognathic Surgery

    PubMed Central

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209

  20. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    PubMed

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.

  1. Actinic cheilitis: proposition and reproducibility of a clinical criterion.

    PubMed

    Poitevin, Nádia Antunes; Rodrigues, Mariana Sudati; Weigert, Karen Loureiro; Macedo, Carmen Lúcia Rodrigues; Dos Santos, Rubem Beraldo

    2017-01-01

    The actinic cheilitis (AC) is a precancerous lip lesion seen as a consequence of chronic sun exposure. Clinically, the border between the lip's skin and the semimucosa could be blurred; in the more aggressive cases, leucoplakia and ulcers also represent its clinical feature. It seems that no clinical criterion is universally accepted for this disease yet. Therefore, this study was carried out to make a proposition of a clinical score to actinic cheilitis (Grade I starting from dryness of vermilion to endured ulcers representing Grade IV) and to assess its reproducibility. Fifty subjects were assessed, most of whom were male, Caucasian farmers, with an average age of 46.12 (18-74) years. The obtained data were analysed by means of descriptive statistics and by Kappa test to assess the inter-examiners and the clinical Golden-Pattern concordance (95% CI). During calibration, 15 patients were examined three times a week by each examiner (4) until Kappa test observed k =0.8 or more. In the main experiment, the inter-examiner concordance was classified between good ( k =0.779; P <0.05) and very good ( k =0.925; P <0.05) from the 35 examined subjects. With the Golden-Pattern, it was considered very good ( k =0.812; P <0.05 to k =0.925; P <0.05). Four examiners with different experiences could strongly suggest that after adequate calibration, it could be well applied by examiners with as much experience as a dental student. The authors concluded that the proposed classification was easily applied and had a very good reproducibility.

  2. Portuguese community pharmacists' attitudes to and knowledge of antibiotic misuse: questionnaire development and reliability.

    PubMed

    Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Gonzalez-Gonzalez, Cristian; Figueiras, Adolfo; Herdeiro, Maria Teresa

    2014-01-01

    To develop and evaluate the reliability of a self-administered questionnaire designed to assess the attitudes and knowledge of community pharmacists in Portugal about microbial resistance and the antibiotic dispensing process. This study was divided into the following three stages: (1) design of the questionnaire, which included a literature review and a qualitative study with focus-group sessions; (2) assessment of face and content validity, using a panel of experts and a pre-test of community pharmacists; and, (3) pilot study and reliability analysis, which included a test-retest study covering fifty practising pharmacists based at community pharmacies in five districts situated in Northern Portugal. Questionnaire reproducibility was quantified using the intraclass correlation coefficient (ICC; 95% confidence interval) computed by means of one-way analysis of variance (ANOVA). Internal consistency was evaluated using Cronbach's alpha. The correlation coefficients were fair to good (ICC>0.4) for all statements (scale-items) regarding knowledge of and attitudes to antibiotic resistance, and ranged from fair to good to excellent for statements about situations in which pharmacists acknowledged that antibiotics were sometimes dispensed without a medical prescription (ICC>0.8). Cronbach's alpha for this section was 0.716. The questionnaire designed in this study is valid and reliable in terms of content validity, face validity and reproducibility.

  3. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers.

    PubMed

    Sochat, Vanessa V; Prybol, Cameron J; Kurtzer, Gregory M

    2017-01-01

    Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub's primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers.

  4. Characterization and reproducibility of HepG2 hanging drop spheroids toxicology in vitro.

    PubMed

    Hurrell, Tracey; Ellero, Andrea Antonio; Masso, Zelie Flavienne; Cromarty, Allan Duncan

    2018-02-21

    Hepatotoxicity remains a major challenge in drug development despite preclinical toxicity screening using hepatocytes of human origin. To overcome some limitations of reproducing the hepatic phenotype, more structurally and functionally authentic cultures in vitro can be introduced by growing cells in 3D spheroid cultures. Characterisation and reproducibility of HepG2 spheroid cultures using a high-throughput hanging drop technique was performed and features contributing to potential phenotypic variation highlighted. Cultured HepG2 cells were seeded into Perfecta 3D® 96-well hanging drop plates and assessed over time for morphology, viability, cell cycle distribution, protein content and protein-mass profiles. Divergent aspects which were assessed included cell stocks, seeding density, volume of culture medium and use of extracellular matrix additives. Hanging drops are advantageous due to no complex culture matrix being present, enabling background free extractions for downstream experimentation. Varying characteristics were observed across cell stocks and batches, seeding density, culture medium volume and extracellular matrix when using immortalized HepG2 cells. These factors contribute to wide-ranging cellular responses and highlights concerns with respect to generating a reproducible phenotype in HepG2 hanging drop spheroids. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers

    PubMed Central

    Prybol, Cameron J.; Kurtzer, Gregory M.

    2017-01-01

    Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub’s primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers. PMID:29186161

  6. Discriminatory Power and Reproducibility of Novel DNA Typing Methods for Mycobacterium tuberculosis Complex Strains

    PubMed Central

    Kremer, Kristin; Arnold, Catherine; Cataldi, Angel; Gutiérrez, M. Cristina; Haas, Walter H.; Panaiotov, Stefan; Skuce, Robin A.; Supply, Philip; van der Zanden, Adri G. M.; van Soolingen, Dick

    2005-01-01

    In recent years various novel DNA typing methods have been developed which are faster and easier to perform than the current internationally standardized IS6110 restriction fragment length polymorphism typing method. However, there has been no overview of the utility of these novel typing methods, and it is largely unknown how they compare to previously published methods. In this study, the discriminative power and reproducibility of nine recently described PCR-based typing methods for Mycobacterium tuberculosis were investigated using the strain collection of the interlaboratory study of Kremer et al. (J. Clin. Microbiol. 37:2607-2618, 1999). This strain collection contains 90 M. tuberculosis complex and 10 non-M. tuberculosis complex mycobacterial strains, as well as 31 duplicated DNA samples to assess reproducibility. The highest reproducibility was found with variable numbers of tandem repeat typing using mycobacterial interspersed repetitive units (MIRU VNTR) and fast ligation-mediated PCR (FLiP), followed by second-generation spoligotyping, ligation-mediated PCR (LM-PCR), VNTR typing using five repeat loci identified at the Queens University of Belfast (QUB VNTR), and the Amadio speciation PCR. Poor reproducibility was associated with fluorescent amplified fragment length polymorphism typing, which was performed in three different laboratories. The methods were ordered from highest discrimination to lowest by the Hunter-Gaston discriminative index as follows: QUB VNTR typing, MIRU VNTR typing, FLiP, LM-PCR, and spoligotyping. We conclude that both VNTR typing methods and FLiP typing are rapid, highly reliable, and discriminative epidemiological typing methods for M. tuberculosis and that VNTR typing is the epidemiological typing method of choice for the near future. PMID:16272496

  7. Three-dimensional reproducibility of natural head position.

    PubMed

    Weber, Diana W; Fallis, Drew W; Packer, Mark D

    2013-05-01

    Although natural head position has proven to be reliable in the sagittal plane, with an increasing interest in 3-dimensional craniofacial analysis, a determination of its reproducibility in the coronal and axial planes is essential. This study was designed to evaluate the reproducibility of natural head position over time in the sagittal, coronal, and axial planes of space with 3-dimensional imaging. Three-dimensional photographs were taken of 28 adult volunteers (ages, 18-40 years) in natural head position at 5 times: baseline, 4 hours, 8 hours, 24 hours, and 1 week. Using the true vertical and horizontal laser lines projected in an iCAT cone-beam computed tomography machine (Imaging Sciences International, Hatfield, Pa) for orientation, we recorded references for natural head position on the patient's face with semipermanent markers. By using a 3-dimensional camera system, photographs were taken at each time point to capture the orientation of the reference points. By superimposing each of the 5 photographs on stable anatomic surfaces, changes in the position of the markers were recorded and assessed for parallelism by using 3dMDvultus (3dMD, Atlanta, Ga) and software (Dolphin Imaging & Management Solutions, Chatsworth, Calif). No statistically significant differences were observed between the 5 time points in any of the 3 planes of space. However, a statistically significant difference was observed between the mean angular deviations of 3 reference planes, with a hierarchy of natural head position reproducibility established as coronal > axial > sagittal. Within the parameters of this study, natural head position was found to be reproducible in the sagittal, coronal, and axial planes of space. The coronal plane had the least variation over time, followed by the axial and sagittal planes. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Compared to X-ray, three-dimensional computed tomography measurement is a reproducible radiographic method for normal proximal humerus.

    PubMed

    Jia, Xiaoyang; Chen, Yanxi; Qiang, Minfei; Zhang, Kun; Li, Haobo; Jiang, Yuchen; Zhang, Yijie

    2016-07-15

    Accurate comprehension of the normal humeral morphology is crucial for anatomical reconstruction in shoulder arthroplasty. However, traditional morphological measurements for humerus were mainly based on cadaver and radiography. The purpose of this study was to provide a series of precise and repeatable parameters of the normal proximal humerus for arthroplasty, based on the three-dimensional (3-D) measurements. Radiographic and 3-D computed tomography (CT) measurements of the proximal humerus were performed in a sample of 120 consecutive adults. Sex differences, two image modalities differences, and correlations of the parameters were evaluated. Intra- and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICCs). In the male group, all parameters except the neck-shaft angle of humerus, based on 3-D CT images, were greater than those in the female group (P < 0.05). All variables were significantly different between two image modalities (P < 0.05). In 3-D CT measurement, all parameters expect neck-shaft angle had correlation with each other (P < 0.001), particularly between two diameters of the humeral head (r = 0.907). All parameters in the 3-D CT measurement had excellent reproducibility (ICC range, 0.878 to 0.936) that was higher than those in the radiographs (ICC range, 0.741 to 0.858). The present study suggested that 3-D CT was more reproducible than plain radiography in the assessment of morphology of the normal proximal humerus. Therefore, this reproducible modality could be utilized in the preoperative planning. Our data could serve as an effective guideline for humeral component selection and improve the design of shoulder prosthesis.

  9. Resting-state functional connectivity assessed with two diffuse optical tomographic systems.

    PubMed

    Niu, Haijing; Khadka, Sabin; Tian, Fenghua; Lin, Zi-Jing; Lu, Chunming; Zhu, Chaozhe; Liu, Hanli

    2011-04-01

    Functional near-infrared spectroscopy (fNIRS) is recently utilized as a new approach to assess resting-state functional connectivity (RSFC) in the human brain. For any new technique or new methodology, it is necessary to be able to replicate similar experiments using different instruments in order to establish its liability and reproducibility. We apply two different diffuse optical tomographic (DOT) systems (i.e., DYNOT and CW5), with various probe arrangements to evaluate RSFC in the sensorimotor cortex by utilizing a previously published experimental protocol and seed-based correlation analysis. Our results exhibit similar spatial patterns and strengths in RSFC between the bilateral motor cortexes. The consistent observations are obtained from both DYNOT and CW5 systems, and are also in good agreement with the previous fNIRS study. Overall, we demonstrate that the fNIRS-based RSFC is reproducible by various DOT imaging systems among different research groups, enhancing the confidence of neuroscience researchers and clinicians to utilize fNIRS for future applications.

  10. Development and validation of a large, modular test meal with liquid and solid components for assessment of gastric motor and sensory function by non-invasive imaging.

    PubMed

    Parker, H L; Tucker, E; Hoad, C L; Pal, A; Costigan, C; Hudders, N; Perkins, A; Blackshaw, E; Gowland, P; Marciani, L; Fox, M R

    2016-04-01

    Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study introduces the large 'Nottingham Test Meal' (NTM) for assessment of gastric motor and sensory function by non-invasive imaging. NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and 12 solid agar-beads (0 kcal) with known breaking strength. Gastric fullness and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gastric emptying (GE) were measured in 24 healthy volunteers (HVs) by gastric scintigraphy (GS) and magnetic resonance imaging (MRI). The contribution of secretion to gastric volume was assessed. Parameters that describe GE were calculated from validated models. Inter-observer agreement and reproducibility were assessed. NTM produced moderate fullness (VAS ≥30) but no more than mild dyspeptic symptoms (VAS <30) in 24 HVs. Stable binding of meal components to labels in gastric conditions was confirmed. Distinct early and late-phase GE were detected by both modalities. Liquid GE half-time was median 49 (95% CI: 36-62) min and 68 (57-71) min for GS and MRI, respectively. Differences between GS and MRI measurements were explained by the contribution of gastric secretion. Breaking strength for agar-beads was 0.8 N/m(2) such that median 25 (8-50) % intact agar-beads and 65 (47-74) % solid material remained at 120 min on MRI and GS, respectively. Good reproducibility for liquid GE parameters was present and GE was not altered by agar-beads. The NTM provided an objective assessment of gastric motor and sensory function. The results were reproducible and liquid emptying was not affected by non-nutrient agar-beads. The method is potentially suitable for clinical practice. © 2016 John Wiley & Sons Ltd.

  11. Multislice computed tomography with colon water distension (MSCT-c) in the study of intestinal and ureteral endometriosis.

    PubMed

    Iosca, Simona; Lumia, Domenico; Bracchi, Elena; Duka, Ejona; De Bon, Monica; Lekaj, Manjola; Uccella, Stefano; Ghezzi, Fabio; Fugazzola, Carlo

    2013-01-01

    This study evaluates retrospectively the accuracy and reproducibility of multislice computed tomography with colon water distension (MSCT-c) in diagnosing bowel (BE) and ureteral (UE) endometriosis. Sixty-four patients underwent MSCT-c and videolaparoscopic surgery. Two radiologists reviewed MSCT-c examinations: sensitivity and specificity were calculated, considering histological exam as reference standard. In the BE cases, the degree of bowel wall infiltration was also assessed. Sensitivity and specificity for both readers were 100% and 97.6% for BE and 72.2% and 100% for UE; the interobserver agreement was excellent. The degree of bowel wall involvement was correctly defined in 90.9% of cases. MSCT-c is an accurate and reproducible technique but-considering the age of the patients-delivers a nonnegligible radiation dose. © 2013 Elsevier Inc. All rights reserved.

  12. A Method for the Design and Development of Medical or Health Care Information Websites to Optimize Search Engine Results Page Rankings on Google

    PubMed Central

    Cummins, Niamh Maria; Hannigan, Ailish; Shannon, Bill; Dunne, Colum; Cullen, Walter

    2013-01-01

    Background The Internet is a widely used source of information for patients searching for medical/health care information. While many studies have assessed existing medical/health care information on the Internet, relatively few have examined methods for design and delivery of such websites, particularly those aimed at the general public. Objective This study describes a method of evaluating material for new medical/health care websites, or for assessing those already in existence, which is correlated with higher rankings on Google's Search Engine Results Pages (SERPs). Methods A website quality assessment (WQA) tool was developed using criteria related to the quality of the information to be contained in the website in addition to an assessment of the readability of the text. This was retrospectively applied to assess existing websites that provide information about generic medicines. The reproducibility of the WQA tool and its predictive validity were assessed in this study. Results The WQA tool demonstrated very high reproducibility (intraclass correlation coefficient=0.95) between 2 independent users. A moderate to strong correlation was found between WQA scores and rankings on Google SERPs. Analogous correlations were seen between rankings and readability of websites as determined by Flesch Reading Ease and Flesch-Kincaid Grade Level scores. Conclusions The use of the WQA tool developed in this study is recommended as part of the design phase of a medical or health care information provision website, along with assessment of readability of the material to be used. This may ensure that the website performs better on Google searches. The tool can also be used retrospectively to make improvements to existing websites, thus, potentially enabling better Google search result positions without incurring the costs associated with Search Engine Optimization (SEO) professionals or paid promotion. PMID:23981848

  13. Automated 3D ultrasound measurement of the angle of progression in labor.

    PubMed

    Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly

    2018-01-01

    To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.

  14. Characteristics of the perception of different severity measures of citrus canker and the relations between the various symptom types

    USDA-ARS?s Scientific Manuscript database

    Citrus canker is a disease of citrus and is caused by the bacterial pathogen Xanthomonas axonopodis pv citri (Xac). Ways of managing the disease are being sought, and accurate, precise, reproducible disease assessment is needed for monitoring epidemics. The objective of this study was to investigate...

  15. Hydrological hysteresis and its value for assessing process consistency in catchment conceptual models

    Treesearch

    O. Fovet; L. Ruiz; M. Hrachowitz; M. Faucheux; C. Gascuel-Odoux

    2015-01-01

    While most hydrological models reproduce the general flow dynamics, they frequently fail to adequately mimic system-internal processes. In particular, the relationship between storage and discharge, which often follows annual hysteretic patterns in shallow hard-rock aquifers, is rarely considered in modelling studies. One main reason is that catchment storage is...

  16. Central Corneal Thickness Reproducibility among Ten Different Instruments.

    PubMed

    Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco

    2016-11-01

    To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.

  17. Reproducibility, interrater agreement, and age-related changes of fractional anisotropy measures at 3T in healthy subjects: effect of the applied b-value.

    PubMed

    Bisdas, S; Bohning, D E; Besenski, N; Nicholas, J S; Rumboldt, Z

    2008-06-01

    There is no reproducibility study of fractional anisotropy (FA) measurements at 3T using regions of interest (ROIs). Our purpose was to establish the extent and statistical significance of the interrater variability, the variability observed with 2 different b-values, and in 2 separate scanning sessions. Twelve healthy volunteers underwent MR imaging twice. MR imaging was performed on a 3T unit, and FA maps were analyzed independently by 2 observers using ROIs positioned in the corpus callosum, internal capsules, corticospinal tracts, and right thalamus. Changes in FA values (x10(3)) measured with 2 b-values (700 and 1000 s/mm(2)), age-related differences, interobserver agreement, and measurement reproducibility were assessed. In the right internal capsule genu (FA = 702/728; b = 1000/700 s/mm(2)) and the left anterior limb of the internal capsule (AIC; FA = 617/745; b = 1000/700 s/mm(2)), the FA values were significantly different between the 2 b-values (P = .02 and .05, respectively). Significant age-related differences in FA were observed in the genu of the corpus callosum and in the left AIC. Interrater measurements showed fair-to-moderate agreement for most anatomic structures. The lowest significant change for a single subject regarding any FA values between the 2 sessions was in the corpus callosum (4%), whereas the highest one was in the corticospinal tracts (27%). The Bland-Altman plot analysis showed that the 1000-s/mm(2) b-value gave satisfactorily reproducible measurements equally good or better than the 700-s/mm(2) b-value. The reproducibility of FA estimates using ROIs was satisfactory. Measurements with a b-value at 1000 s/mm(2) showed superior reproducibility in most anatomic locations.

  18. Representativeness of laboratory sampling procedures for the analysis of trace metals in soil.

    PubMed

    Dubé, Jean-Sébastien; Boudreault, Jean-Philippe; Bost, Régis; Sona, Mirela; Duhaime, François; Éthier, Yannic

    2015-08-01

    This study was conducted to assess the representativeness of laboratory sampling protocols for purposes of trace metal analysis in soil. Five laboratory protocols were compared, including conventional grab sampling, to assess the influence of sectorial splitting, sieving, and grinding on measured trace metal concentrations and their variability. It was concluded that grinding was the most important factor in controlling the variability of trace metal concentrations. Grinding increased the reproducibility of sample mass reduction by rotary sectorial splitting by up to two orders of magnitude. Combined with rotary sectorial splitting, grinding increased the reproducibility of trace metal concentrations by almost three orders of magnitude compared to grab sampling. Moreover, results showed that if grinding is used as part of a mass reduction protocol by sectorial splitting, the effect of sieving on reproducibility became insignificant. Gy's sampling theory and practice was also used to analyze the aforementioned sampling protocols. While the theoretical relative variances calculated for each sampling protocol qualitatively agreed with the experimental variances, their quantitative agreement was very poor. It was assumed that the parameters used in the calculation of theoretical sampling variances may not correctly estimate the constitutional heterogeneity of soils or soil-like materials. Finally, the results have highlighted the pitfalls of grab sampling, namely, the fact that it does not exert control over incorrect sampling errors and that it is strongly affected by distribution heterogeneity.

  19. PH Tester Gauge Repeatability and Reproducibility Study for WO3 Nanostructure Hydrothermal Growth Process

    NASA Astrophysics Data System (ADS)

    Abd Rashid, Amirul; Hayati Saad, Nor; Bien Chia Sheng, Daniel; Yee, Lee Wai

    2014-06-01

    PH value is one of the important variables for tungsten trioxide (WO3) nanostructure hydrothermal synthesis process. The morphology of the synthesized nanostructure can be properly controlled by measuring and controlling the pH value of the solution used in this facile synthesis route. Therefore, it is very crucial to ensure the gauge used for pH measurement is reliable in order to achieve the expected result. In this study, gauge repeatability and reproducibility (GR&R) method was used to assess the repeatability and reproducibility of the pH tester. Based on ANOVA method, the design of experimental metrics as well as the result of the experiment was analyzed using Minitab software. It was found that the initial GR&R value for the tester was at 17.55 % which considered as acceptable. To further improve the GR&R level, a new pH measuring procedure was introduced. With the new procedure, the GR&R value was able to be reduced to 2.05%, which means the tester is statistically very ideal to measure the pH of the solution prepared for WO3 hydrothermal synthesis process.

  20. Reproducibility of the measurement of sweet taste preferences.

    PubMed

    Asao, Keiko; Luo, Wendy; Herman, William H

    2012-12-01

    Developing interventions to prevent and treat obesity are medical and public health imperatives. Taste is a major determinant of food intake and reliable methods to measure taste preferences need to be established. This study aimed to establish the short-term reproducibility of sweet taste preference measurements using 5-level sucrose concentrations in healthy adult volunteers. We defined sweet taste preference as the geometric mean of the preferred sucrose concentration determined from two series of two-alternative, forced-choice staircase procedures administered 10min apart on a single day. We repeated the same procedures at a second visit 3-7days later. Twenty-six adults (13 men and 13 women, age 33.2±12.2years) completed the measurements. The median number of pairs presented for each series was three (25th and 75th percentiles: 3, 4). The intraclass correlation coefficients between the measurements was 0.82 (95% confidence interval [CI]: 0.63-0.92) within a few days. This study showed high short-term reproducibility of a simple, 5-level procedure for measuring sweet taste preferences. This method may be useful for assessing sweet taste preferences and the risks resulting from those preferences. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. A QC approach to the determination of day-to-day reproducibility and robustness of LC-MS methods for global metabolite profiling in metabonomics/metabolomics.

    PubMed

    Gika, Helen G; Theodoridis, Georgios A; Earll, Mark; Wilson, Ian D

    2012-09-01

    An approach to the determination of day-to-day analytical robustness of LC-MS-based methods for global metabolic profiling using a pooled QC sample is presented for the evaluation of metabonomic/metabolomic data. A set of 60 urine samples were repeatedly analyzed on five different days and the day-to-day reproducibility of the data obtained was determined. Multivariate statistical analysis was performed with the aim of evaluating variability and selected peaks were assessed and validated in terms of retention time stability, mass accuracy and intensity. The methodology enables the repeatability/reproducibility of extended analytical runs in large-scale studies to be determined, allowing the elimination of analytical (as opposed to biological) variability, in order to discover true patterns and correlations within the data. The day-to-day variability of the data revealed by this process suggested that, for this particular system, 3 days continuous operation was possible without the need for maintenance and cleaning. Variation was generally based on signal intensity changes over the 7-day period of the study, and was mainly a result of source contamination.

  2. Estimation of contrast agent bolus arrival delays for improved reproducibility of liver DCE MRI

    NASA Astrophysics Data System (ADS)

    Chouhan, Manil D.; Bainbridge, Alan; Atkinson, David; Punwani, Shonit; Mookerjee, Rajeshwar P.; Lythgoe, Mark F.; Taylor, Stuart A.

    2016-10-01

    Delays between contrast agent (CA) arrival at the site of vascular input function (VIF) sampling and the tissue of interest affect dynamic contrast enhanced (DCE) MRI pharmacokinetic modelling. We investigate effects of altering VIF CA bolus arrival delays on liver DCE MRI perfusion parameters, propose an alternative approach to estimating delays and evaluate reproducibility. Thirteen healthy volunteers (28.7  ±  1.9 years, seven males) underwent liver DCE MRI using dual-input single compartment modelling, with reproducibility (n  =  9) measured at 7 days. Effects of VIF CA bolus arrival delays were assessed for arterial and portal venous input functions. Delays were pre-estimated using linear regression, with restricted free modelling around the pre-estimated delay. Perfusion parameters and 7 days reproducibility were compared using this method, freely modelled delays and no delays using one-way ANOVA. Reproducibility was assessed using Bland-Altman analysis of agreement. Maximum percent change relative to parameters obtained using zero delays, were  -31% for portal venous (PV) perfusion, +43% for total liver blood flow (TLBF), +3247% for hepatic arterial (HA) fraction, +150% for mean transit time and  -10% for distribution volume. Differences were demonstrated between the 3 methods for PV perfusion (p  =  0.0085) and HA fraction (p  <  0.0001), but not other parameters. Improved mean differences and Bland-Altman 95% Limits-of-Agreement for reproducibility of PV perfusion (9.3 ml/min/100 g, ±506.1 ml/min/100 g) and TLBF (43.8 ml/min/100 g, ±586.7 ml/min/100 g) were demonstrated using pre-estimated delays with constrained free modelling. CA bolus arrival delays cause profound differences in liver DCE MRI quantification. Pre-estimation of delays with constrained free modelling improved 7 days reproducibility of perfusion parameters in volunteers.

  3. Validation of a buffet meal design in an experimental restaurant.

    PubMed

    Allirot, Xavier; Saulais, Laure; Disse, Emmanuel; Roth, Hubert; Cazal, Camille; Laville, Martine

    2012-06-01

    We assessed the reproducibility of intakes and meal mechanics parameters (cumulative energy intake (CEI), number of bites, bite rate, mean energy content per bite) during a buffet meal designed in a natural setting, and their sensitivity to food deprivation. Fourteen men were invited to three lunch sessions in an experimental restaurant. Subjects ate their regular breakfast before sessions A and B. They skipped breakfast before session FAST. The same ad libitum buffet was offered each time. Energy intakes and meal mechanics were assessed by foods weighing and video recording. Intrasubject reproducibility was evaluated by determining intraclass correlation coefficients (ICC). Mixed-models were used to assess the effects of the sessions on CEI. We found a good reproducibility between A and B for total energy (ICC=0.82), carbohydrate (ICC=0.83), lipid (ICC=0.81) and protein intake (ICC=0.79) and for meal mechanics parameters. Total energy, lipid and carbohydrate intake were higher in FAST than in A and B. CEI were found sensitive to differences in hunger level while the other meal mechanics parameters were stable between sessions. In conclusion, a buffet meal in a normal eating environment is a valid tool for assessing the effects of interventions on intakes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods

    PubMed Central

    AlBarakati, SF; Kula, KS; Ghoneima, AA

    2012-01-01

    Objective The aim of this study was to assess the reliability and reproducibility of angular and linear measurements of conventional and digital cephalometric methods. Methods A total of 13 landmarks and 16 skeletal and dental parameters were defined and measured on pre-treatment cephalometric radiographs of 30 patients. The conventional and digital tracings and measurements were performed twice by the same examiner with a 6 week interval between measurements. The reliability within the method was determined using Pearson's correlation coefficient (r2). The reproducibility between methods was calculated by paired t-test. The level of statistical significance was set at p < 0.05. Results All measurements for each method were above 0.90 r2 (strong correlation) except maxillary length, which had a correlation of 0.82 for conventional tracing. Significant differences between the two methods were observed in most angular and linear measurements except for ANB angle (p = 0.5), angle of convexity (p = 0.09), anterior cranial base (p = 0.3) and the lower anterior facial height (p = 0.6). Conclusion In general, both methods of conventional and digital cephalometric analysis are highly reliable. Although the reproducibility of the two methods showed some statistically significant differences, most differences were not clinically significant. PMID:22184624

  5. Factors affecting reproducibility between genome-scale siRNA-based screens

    PubMed Central

    Barrows, Nicholas J.; Le Sommer, Caroline; Garcia-Blanco, Mariano A.; Pearson, James L.

    2011-01-01

    RNA interference-based screening is a powerful new genomic technology which addresses gene function en masse. To evaluate factors influencing hit list composition and reproducibility, we performed two identically designed small interfering RNA (siRNA)-based, whole genome screens for host factors supporting yellow fever virus infection. These screens represent two separate experiments completed five months apart and allow the direct assessment of the reproducibility of a given siRNA technology when performed in the same environment. Candidate hit lists generated by sum rank, median absolute deviation, z-score, and strictly standardized mean difference were compared within and between whole genome screens. Application of these analysis methodologies within a single screening dataset using a fixed threshold equivalent to a p-value ≤ 0.001 resulted in hit lists ranging from 82 to 1,140 members and highlighted the tremendous impact analysis methodology has on hit list composition. Intra- and inter-screen reproducibility was significantly influenced by the analysis methodology and ranged from 32% to 99%. This study also highlighted the power of testing at least two independent siRNAs for each gene product in primary screens. To facilitate validation we conclude by suggesting methods to reduce false discovery at the primary screening stage. In this study we present the first comprehensive comparison of multiple analysis strategies, and demonstrate the impact of the analysis methodology on the composition of the “hit list”. Therefore, we propose that the entire dataset derived from functional genome-scale screens, especially if publicly funded, should be made available as is done with data derived from gene expression and genome-wide association studies. PMID:20625183

  6. Body Dysmorphic Symptoms Scale for patients seeking esthetic surgery: cross-cultural validation study.

    PubMed

    Ramos, Tatiana Dalpasquale; Brito, Maria José Azevedo de; Piccolo, Mônica Sarto; Rosella, Maria Fernanda Normanha da Silva Martins; Sabino, Miguel; Ferreira, Lydia Masako

    2016-07-21

    Rhinoplasty is one of the most sought-after esthetic operations among individuals with body dysmorphic disorder. The aim of this study was to cross-culturally adapt and validate the Body Dysmorphic Symptoms Scale. Cross-cultural validation study conducted in a plastic surgery outpatient clinic of a public university hospital. Between February 2014 and March 2015, 80 consecutive patients of both sexes seeking rhinoplasty were selected. Thirty of them participated in the phase of cultural adaptation of the instrument. Reproducibility was tested on 20 patients and construct validity was assessed on 50 patients, with correlation against the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder. The Brazilian version of the instrument showed Cronbach's alpha of 0.805 and excellent inter-rater reproducibility (intraclass correlation coefficient, ICC = 0.873; P < 0.001) and intra-rater reproducibility (ICC = 0.939; P < 0.001). Significant differences in total scores were found between patients with and without symptoms (P < 0.001). A strong correlation (r = 0.841; P < 0.001) was observed between the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder and the Body Dysmorphic Symptoms Scale. The area under the receiver operating characteristic curve was 0.981, thus showing good accuracy for discriminating between presence and absence of symptoms of body dysmorphic disorder. Forty-six percent of the patients had body dysmorphic symptoms and 54% had moderate to severe appearance-related obsessive-compulsive symptoms. The Brazilian version of the Body Dysmorphic Symptoms Scale is a reproducible instrument that presents face, content and construct validity.

  7. Body Dysmorphic Symptoms Scale for patients seeking esthetic surgery: cross-cultural validation study.

    PubMed

    Ramos, Tatiana Dalpasquale; Brito, Maria José Azevedo de; Piccolo, Mônica Sarto; Rosella, Maria Fernanda Normanha da Silva Martins; Sabino, Miguel; Ferreira, Lydia Masako

    2016-01-01

    Rhinoplasty is one of the most sought-after esthetic operations among individuals with body dysmorphic disorder. The aim of this study was to cross-culturally adapt and validate the Body Dysmorphic Symptoms Scale. Cross-cultural validation study conducted in a plastic surgery outpatient clinic of a public university hospital. Between February 2014 and March 2015, 80 consecutive patients of both sexes seeking rhinoplasty were selected. Thirty of them participated in the phase of cultural adaptation of the instrument. Reproducibility was tested on 20 patients and construct validity was assessed on 50 patients, with correlation against the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder. The Brazilian version of the instrument showed Cronbach's alpha of 0.805 and excellent inter-rater reproducibility (intraclass correlation coefficient, ICC = 0.873; P < 0.001) and intra-rater reproducibility (ICC = 0.939; P < 0.001). Significant differences in total scores were found between patients with and without symptoms (P < 0.001). A strong correlation (r = 0.841; P < 0.001) was observed between the Yale-Brown Obsessive Compulsive Scale for Body Dysmorphic Disorder and the Body Dysmorphic Symptoms Scale. The area under the receiver operating characteristic curve was 0.981, thus showing good accuracy for discriminating between presence and absence of symptoms of body dysmorphic disorder. Forty-six percent of the patients had body dysmorphic symptoms and 54% had moderate to severe appearance-related obsessive-compulsive symptoms. The Brazilian version of the Body Dysmorphic Symptoms Scale is a reproducible instrument that presents face, content and construct validity.

  8. Development and Validation of a Food Frequency Questionnaire to Estimate Intake among Children and Adolescents in Urban Peru

    PubMed Central

    Rodriguez, Carly A.; Smith, Emily R.; Villamor, Eduardo; Zavaleta, Nelly; Respicio-Torres, Graciela; Contreras, Carmen; Perea, Sara; Jimenez, Judith; Tintaya, Karen; Lecca, Leonid; Murray, Megan B.; Franke, Molly F.

    2017-01-01

    Tools to assess intake among children in Latin America are limited. We developed and assessed the reproducibility and validity of a semi-quantitative food frequency questionnaire (FFQ) administered to children, adolescents, and their caregivers in Lima, Peru. We conducted 24-h diet recalls (DRs) and focus groups to develop a locally-tailored FFQ prototype for children aged 0–14 years. To validate the FFQ, we administered two FFQs and three DRs to children and/or their caregivers (N = 120) over six months. We examined FFQ reproducibility by quartile agreement and Pearson correlation coefficients, and validity by quartile agreement and correlation with DRs. For reproducibility, quartile agreement ranged from 60–77% with correlations highest for vitamins A and C (0.31). Age-adjusted correlations for the mean DR and the second-administered FFQ were highest in the 0–7 age group, in which the majority of caregivers completed the FFQ on behalf of the child (total fat; 0.67) and in the 8–14 age group, in which both the child and caregiver completed the FFQ together (calcium, niacin; 0.54); correlations were <0.10 for most nutrients in the 8–14 age group in which the caregiver completed the FFQ on the child’s behalf. The FFQ was reproducible and the first developed and validated to assess various nutrients in children and adolescents in Peru. PMID:29036893

  9. Reproducibility of serum IgE, Ara h2 skin prick testing and fraction of exhaled nitric oxide for predicting clinical peanut allergy in children.

    PubMed

    Percival, Elizabeth; Bhatia, Rani; Preece, Kahn; McElduff, Patrick; McEvoy, Mark; Collison, Adam; Mattes, Joerg

    2016-01-01

    Ara h2 sIgE serum levels improve the diagnostic accuracy for predicting peanut allergy, but the use of Ara h2 purified protein as a skin prick test (SPT), has not been substantially evaluated. The fraction of exhaled nitric oxide (FeNO) shows promise as a novel biomarker of peanut allergy. Reproducibility of these measures has not been determined. The aim was to assess the accuracy and reproducibility (over a time-period of at least 12 months) of SPT to Ara h2 in comparison with four predictors of clinical peanut allergy (Peanut SPT, Ara h2 specific Immunoglobulin E (sIgE), Peanut sIgE and FeNO). Twenty-seven children were recruited in a follow-up of a prospective cohort of fifty-six children at least 12 months after an open-labelled peanut food challenge. Their repeat assessment involved a questionnaire, SPT to peanut and Ara h2 purified protein, FeNO and sIgE to peanut and Ara h2 measurements. Ara h2 SPT was no worse in accuracy when compared with peanut SPT, FeNO, Ara h2 sIgE and peanut sIgE (AUC 0.908 compared with 0.887, 0.889, 0.935 and 0.804 respectively) for predicting allergic reaction at previous food challenge. SPT for peanut and Ara h2 demonstrated limited reproducibility (ICC = 0.51 and 0.44); while FeNO demonstrated good reproducibility (ICC = 0.73) and sIgE for peanut and Ara h2 were highly reproducible (ICC = 0.81 and 0.85). In this population, Ara h2 SPT was no worse in accuracy when compared with current testing for the evaluation of clinical peanut allergy, but had-like peanut SPT-poor reproducibility. FeNO, peanut sIgE and Ara h2 sIgE were consistently reproducible despite an interval of at least 12 months between the repeated measurements.

  10. Reproducibility in Natural Language Processing: A Case Study of Two R Libraries for Mining PubMed/MEDLINE

    PubMed Central

    Cohen, K. Bretonnel; Xia, Jingbo; Roeder, Christophe; Hunter, Lawrence E.

    2018-01-01

    There is currently a crisis in science related to highly publicized failures to reproduce large numbers of published studies. The current work proposes, by way of case studies, a methodology for moving the study of reproducibility in computational work to a full stage beyond that of earlier work. Specifically, it presents a case study in attempting to reproduce the reports of two R libraries for doing text mining of the PubMed/MEDLINE repository of scientific publications. The main findings are that a rational paradigm for reproduction of natural language processing papers can be established; the advertised functionality was difficult, but not impossible, to reproduce; and reproducibility studies can produce additional insights into the functioning of the published system. Additionally, the work on reproducibility lead to the production of novel user-centered documentation that has been accessed 260 times since its publication—an average of once a day per library. PMID:29568821

  11. Cross-cultural adaptation and reproducibility of the Brazilian-Portuguese version of the modified FRESNO Test to evaluate the competence in evidence based practice by physical therapists

    PubMed Central

    Silva, Anderson M.; Costa, Lucíola C. M.; Comper, Maria L.; Padula, Rosimeire S.

    2016-01-01

    BACKGROUND: The Modified Fresno Test was developed to assess knowledge and skills of both physical therapy (PT) professionals and students to use evidence-based practice (EBP). OBJECTIVES: To translate the Modified Fresno Test into Brazilian-Portuguese and to evaluate the test's reproducibility. METHOD: The first step consisted of adapting the instrument into the Brazilian-Portuguese language. Then, a total of 57 participants, including PT students, PT professors and PT practitioners, completed the translated instrument. The responses from the participants were used to evaluate reproducibility of the translated instrument. Internal consistency was calculated using the Cronbach's alpha. Reliability was calculated using the intraclass correlation coefficient (ICC) for continuous variables, and the Kappa coefficient (K) for categorical variables. The agreement was assessed using the standard error of the measurement (SEM). RESULTS: The cross-cultural adaptation process was appropriate, providing an adequate Brazilian-Portuguese version of the instrument. The internal consistency was good (α=0.769). The reliability for inter- and intra-rater assessment were ICC=0.89 (95% CI 0.82 to 0.93); for evaluator 1 was ICC=0.85 (95% CI 0.57 to 0.93); and for evaluator 2 was ICC=0.98 (95% CI 0.97 to 0.99). The SEM was 13.04 points for inter-rater assessment, 12.57 points for rater 1 and 4.59 points for rater 2. CONCLUSION: The Brazilian-Portuguese language version of the Modified Fresno Test showed satisfactory results in terms of reproducibility. The Modified Fresno Test will allow physical therapy professionals and students to be evaluated on the use of understanding EBP. PMID:26786079

  12. Cross-cultural adaptation and reproducibility of the Brazilian-Portuguese version of the modified FRESNO Test to evaluate the competence in evidence based practice by physical therapists.

    PubMed

    Silva, Anderson M; Costa, Lucíola C M; Comper, Maria L; Padula, Rosimeire S

    2016-01-01

    The Modified Fresno Test was developed to assess knowledge and skills of both physical therapy (PT) professionals and students to use evidence-based practice (EBP). To translate the Modified Fresno Test into Brazilian-Portuguese and to evaluate the test's reproducibility. The first step consisted of adapting the instrument into the Brazilian-Portuguese language. Then, a total of 57 participants, including PT students, PT professors and PT practitioners, completed the translated instrument. The responses from the participants were used to evaluate reproducibility of the translated instrument. Internal consistency was calculated using the Cronbach's alpha. Reliability was calculated using the intraclass correlation coefficient (ICC) for continuous variables, and the Kappa coefficient (K) for categorical variables. The agreement was assessed using the standard error of the measurement (SEM). The cross-cultural adaptation process was appropriate, providing an adequate Brazilian-Portuguese version of the instrument. The internal consistency was good (α=0.769). The reliability for inter- and intra-rater assessment were ICC=0.89 (95% CI 0.82 to 0.93); for evaluator 1 was ICC=0.85 (95% CI 0.57 to 0.93); and for evaluator 2 was ICC=0.98 (95% CI 0.97 to 0.99). The SEM was 13.04 points for inter-rater assessment, 12.57 points for rater 1 and 4.59 points for rater 2. The Brazilian-Portuguese language version of the Modified Fresno Test showed satisfactory results in terms of reproducibility. The Modified Fresno Test will allow physical therapy professionals and students to be evaluated on the use of understanding EBP.

  13. Determinants of the reliability of ultrasound tomography sound speed estimates as a surrogate for volumetric breast density

    PubMed Central

    Khodr, Zeina G.; Sak, Mark A.; Pfeiffer, Ruth M.; Duric, Nebojsa; Littrup, Peter; Bey-Knight, Lisa; Ali, Haythem; Vallieres, Patricia; Sherman, Mark E.; Gierach, Gretchen L.

    2015-01-01

    Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density. PMID:26429241

  14. Determinants of the reliability of ultrasound tomography sound speed estimates as a surrogate for volumetric breast density

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khodr, Zeina G.; Pfeiffer, Ruth M.; Gierach, Gretchen L., E-mail: GierachG@mail.nih.gov

    Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (twomore » scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.« less

  15. Exploring the Role of Information Professionals in Improving Research Reproducibility:A Case Study in Geosciences

    NASA Astrophysics Data System (ADS)

    Yan, A.; West, J.

    2016-12-01

    The validity of Geosciences research is of great significance to general public and policy-makers. In an earlier study, we surveyed 136 faculty and graduate students in geosciences. The result indicated that nearly 80% of respondents who had ever reproduced a published study had failed at least one time in reproducing, suggesting a general lack of research reproducibility in geosciences. Although there is much enthusiasm for creation of technologies such as workflow system, literate programming, and cloud-based system to facilitate reproducibility, much less emphasis has been placed on the information services essential for meaningful use of these tools. Library and Information Science (LIS) has a rich tradition of providing customized service for research communities. LIS professionals such as academic librarians have made strong contribution to resources locating, software recommending, data curation, metadata guidance, project management, submission review and author training. In particular, university libraries have been actively developing tools and offering guidelines, consultations, and trainings on Data Management Plan (DMP) required by National Science Foundation (NSF). And effective data management is a significant first step towards reproducible research. Hereby we argue that LIS professionals may be well-positioned to assist researchers to make their research reproducible. In this study, we aim to answer the question: how can LIS professionals assist geoscience researchers in making their research capable of being reproduced? We first synthesize different definitions of "reproducibility" and provide a conceptual framework of "reproducibility" in geosciences to resolve some of the misunderstandings around related terminology. Using a case study approach, we then examine 1) university librarians' technical skills, domain knowledge, professional activities, together with their awareness of, readiness for, and attitudes towards research reproducibility and 2) geosciences researcher needs for assistance in making research reproducible and attitude towards LIS services. The results of our study provide empirical evidence for an extension of library services, as well as for a potential solution in facilitating research reproducibility.

  16. Test-retest assessment of functional near-infrared spectroscopy to measure risk decision making in young adults

    NASA Astrophysics Data System (ADS)

    Li, Lin; Lin, Zijing; Cazzell, Mary; Liu, Hanli

    2013-03-01

    Investigation of the reliability and reproducibility of the hemodynamic response is important for interpretation and understanding of the results of functional near-infrared spectroscopy (fNIRS). It measures optical signals absorbed by the brain tissue and reflects the neuronal activities indirectly. Here we described an fNIRS study measured in the prefrontal region (Brodman area 9, 10, part of 46)to examine the risk decision-making behavior in nine young adults. The Balloon Analog Risk Task (BART) is widely used to test the level of risk taking ability in the field of psychology. BART was a protocol utilized in this study to evoke a risk-taking environment with a gambling-like balloon game in each subject. Specifically, we recorded the brain oxygenated-hemoglobin (HbO) and deoxygenated-hemoglobin (HHb) changes during the two repeated measurements within a time interval of 3 weeks. The results demonstrate that the changes in HbO2 amplitudes have high reliability at the group level, and that the spatial patterns of the tomographic images have high reproducibility in size and a moderate degree of overlap. Overall, this study confirms that the hemodynamic response to risk decision-making (i.e., BART) seen by fNIRS is highly reliable and reproducible.

  17. Reproducibility and effect of posture on impulse oscillation parameters in persons with spinal cord injury

    PubMed Central

    Cirnigliaro, Christopher M.; Lesser, Marvin; Moyer, Jeremy; Kirshblum, Steven C.; Bauman, William A.; Spungen, Ann M.

    2012-01-01

    Background The impulse oscillation system (IOS) offers significant value in the assessment of airway dynamics in persons with spinal cord injury (SCI) because of minimal patient effort but measurement reproducibility in SCI is unknown. Objective To evaluate between-day reproducibility and the effect of posture on airway resistance [respiratory resistances at 5 Hz (R5) and 20 Hz (R20)] in subjects with tetraplegia, paraplegia and able-bodied controls. Methods Ten subjects with tetraplegia, 10 subjects with paraplegia and 11 able-bodied individuals were evaluated using IOS. Three 30 second trials were obtained in each while in the seated and supine position on Day 1, and repeated on Day 2. Results The within-day coefficient of variation (CV%) for R5 and R20 were comparable in the 3 study groups in the seated and supine positions. Compared to controls, the between-day CV% for the combined data was higher in subjects with tetraplegia and paraplegia for R5 seated, and was higher in subjects with tetraplegia for R5 supine. Conclusions IOS has applicability to the study of within-day respiratory resistance in SCI. However, performing longer-term studies in subjects with tetraplegia and paraplegia may be problematic because of the greater variability for R5 when compared to able-bodied individuals. PMID:22330188

  18. Development and relative validation of a food frequency questionnaire for French-Canadian adolescent and young adult survivors of acute lymphoblastic leukemia.

    PubMed

    Morel, Sophia; Portolese, Olivia; Chertouk, Yasmine; Leahy, Jade; Bertout, Laurence; Laverdière, Caroline; Krajinovic, Maja; Sinnett, Daniel; Levy, Emile; Marcil, Valérie

    2018-04-21

    Survivors of childhood acute lymphoblastic leukemia (cALL) experience cardiometabolic and bone complications after treatments. This study aimed at developing and validating an interview-administrated food frequency questionnaire (FFQ) that will serve to estimate the impact of nutrition in the development of long-term sequalea of French-Canadian cALL survivors. The FFQ was developed to assess habitual diet, Mediterranean diet score, nutrients promoting bone health and antioxidants. It was validated using a 3-day food record (3-DFR) in 80 cALL survivors (50% male) aged between 11.4 and 40.1 years (median of 18.0 years). Reproducibility was evaluated by comparing FFQs from visit 1 and 2 in 29 cALL survivors. When compared to 3-DFR, the mean values for macro- and micronutrient intake were overestimated by our FFQ with the exception of lipid-related nutrients. Correlations between nutrient intakes derived from the FFQs and the 3-DFRs showed moderate to very good correlations (0.46-0.74). Intraclass correlation coefficients assessing FFQ reproducibility ranged from 0.62 to 0.92, indicating moderate to good reliability. Furthermore, classification into quartiles showed more than 75% of macro- and micronutrients derived from FFQs 1 and 2 classified into the same or adjacent quartile. Overall, our results support the reproducibility and accuracy of the developed FFQ to appropriately classify individuals according to their dietary intake. This validated tool will be valuable for future studies analyzing the impact of nutrition on cardiometabolic and bone complications in French-speaking populations.

  19. SU-D-BRA-07: A Phantom Study to Assess the Variability in Radiomics Features Extracted From Cone-Beam CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fave, X; Fried, D; UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX

    2015-06-15

    Purpose: Several studies have demonstrated the prognostic potential for texture features extracted from CT images of non-small cell lung cancer (NSCLC) patients. The purpose of this study was to determine if these features could be extracted with high reproducibility from cone-beam CT (CBCT) images in order for features to be easily tracked throughout a patient’s treatment. Methods: Two materials in a radiomics phantom, designed to approximate NSCLC tumor texture, were used to assess the reproducibility of 26 features. This phantom was imaged on 9 CBCT scanners, including Elekta and Varian machines. Thoracic and head imaging protocols were acquired on eachmore » machine. CBCT images from 27 NSCLC patients imaged using the thoracic protocol on Varian machines were obtained for comparison. The variance for each texture measured from these patients was compared to the variance in phantom values for different manufacturer/protocol subsets. Levene’s test was used to identify features which had a significantly smaller variance in the phantom scans versus the patient data. Results: Approximately half of the features (13/26 for material1 and 15/26 for material2) had a significantly smaller variance (p<0.05) between Varian thoracic scans of the phantom compared to patient scans. Many of these same features remained significant for the head scans on Varian (12/26 and 8/26). However, when thoracic scans from Elekta and Varian were combined, only a few features were still significant (4/26 and 5/26). Three features (skewness, coarsely filtered mean and standard deviation) were significant in almost all manufacturer/protocol subsets. Conclusion: Texture features extracted from CBCT images of a radiomics phantom are reproducible and show significantly less variation than the same features measured from patient images when images from the same manufacturer or with similar parameters are used. Reproducibility between CBCT scanners may be high enough to allow the extraction of meaningful texture values for patients. This project was funded in part by the Cancer Prevention Research Institute of Texas (CPRIT). Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.« less

  20. Reproducibility of thoracic kyphosis measurements in patients with adolescent idiopathic scoliosis.

    PubMed

    Ohrt-Nissen, Søren; Cheung, Jason Pui Yin; Hallager, Dennis Winge; Gehrchen, Martin; Kwan, Kenny; Dahl, Benny; Cheung, Kenneth M C; Samartzis, Dino

    2017-01-01

    Current surgical treatment for adolescent idiopathic scoliosis (AIS) involves correction in both the coronal and sagittal plane, and thorough assessment of these parameters is essential for evaluation of surgical results. However, various definitions of thoracic kyphosis (TK) have been proposed, and the intra- and inter-rater reproducibility of these measures has not been determined. As such, the purpose of the current study was to determine the intra- and inter-rater reproducibility of several TK measurements used in the assessment of AIS. Twenty patients (90% females) surgically treated for AIS with alternate-level pedicle screw fixation were included in the study. Three raters independently evaluated pre- and postoperative standing lateral plain radiographs. For each radiograph, several definitions of TK were measured as well as L1-S1 and nonfixed lumbar lordosis. All variables were measured twice 14 days apart, and a mixed effects model was used to determine the repeatability coefficient (RC), which is a measure of the agreement between repeated measurements. Also, the intra- and inter-rater intra-class correlation coefficient (ICC) was determined as a measure of reliability. Preoperative median Cobb angle was 58° (range 41°-86°), and median surgical curve correction was 68% (range 49-87%). Overall intra-rater RC was highest for T2-T12 and nonfixed TK (11°) and lowest for T4-T12 and T5-T12 (8°). Inter-rater RC was highest for T1-T12, T1-nonfixed, and nonfixed TK (13°) and lowest for T5-T12 (9°). Agreement varied substantially between pre- and postoperative radiographs. Inter-rater ICC was highest for T4-T12 (0.92; 95% CI 0.88-0.95) and T5-T12 (0.92; 95% CI 0.88-0.95) and lowest for T1-nonfixed (0.80; 95% CI 0.72-0.88). Considerable variation for all TK measurements was noted. Intra- and inter-rater reproducibility was best for T4-T12 and T5-T12. Future studies should consider adopting a relevant minimum difference as a limit for true change in TK.

  1. Simultaneous Assessment of Myocardial Perfusion, Wall Motion, and Deformation during Myocardial Contrast Echocardiography: A Feasibility Study.

    PubMed

    Zoppellaro, Giacomo; Venneri, Lucia; Khattar, Rajdeep S; Li, Wei; Senior, Roxy

    2016-06-01

    Ultrasound contrast agents may be used for the assessment of regional wall motion and myocardial perfusion, but are generally considered not suitable for deformation analysis. The aim of our study was to assess the feasibility of deformation imaging on contrast-enhanced images using a novel methodology. We prospectively enrolled 40 patients who underwent stress echocardiography with continuous intravenous infusion of SonoVue for the assessment of myocardial perfusion imaging with flash replenishment technique. We compared longitudinal strain (Lε) values, assessed with a vendor-independent software (2D CPA), on 68 resting contrast-enhanced and 68 resting noncontrast recordings. Strain analysis on contrast recordings was evaluated in the first cardiac cycles after the flash. Tracking of contrast images was deemed feasible in all subjects and in all views. Contrast administration improved image quality and increased the number of segments used for deformation analysis. Lε of noncontrast and contrast-enhanced images were statistically different (-18.8 ± 4.5% and -22.8 ± 5.4%, respectively; P < 0.001), but their correlation was good (ICC 0.65, 95%CI 0.42-0.78). Patients with resting wall-motion abnormalities showed lower Lε values on contrast recordings (-18.6 ± 6.0% vs. -24.2 ± 5.5%, respectively; P < 0.01). Intra-operator and inter-operator reproducibility was good for both noncontrast and contrast images with no statistical differences. Our study shows that deformation analysis on postflash contrast-enhanced images is feasible and reproducible. Therefore, it would be possible to perform a simultaneous evaluation of wall-motion abnormalities, volumes, ejection fraction, perfusion defects, and cardiac deformation on the same contrast recording. © 2016, Wiley Periodicals, Inc.

  2. Assessment of Clinical Skills Using Simulator Technologies

    ERIC Educational Resources Information Center

    Srinivasan, Malathi; Hwang, Judith C.; West, Daniel; Yellowlees, Peter M.

    2006-01-01

    Objective: Simulation technologies are used to assess and teach competencies through the provision of reproducible stimuli. They have exceptional utility in assessing responses to clinical stimuli that occur sporadically or infrequently. In this article, the authors describe the utility of emerging simulation technologies, and discuss critical…

  3. Ferrets as Models for Influenza Virus Transmission Studies and Pandemic Risk Assessments

    PubMed Central

    Barclay, Wendy; Barr, Ian; Fouchier, Ron A.M.; Matsuyama, Ryota; Nishiura, Hiroshi; Peiris, Malik; Russell, Charles J.; Subbarao, Kanta; Zhu, Huachen

    2018-01-01

    The ferret transmission model is extensively used to assess the pandemic potential of emerging influenza viruses, yet experimental conditions and reported results vary among laboratories. Such variation can be a critical consideration when contextualizing results from independent risk-assessment studies of novel and emerging influenza viruses. To streamline interpretation of data generated in different laboratories, we provide a consensus on experimental parameters that define risk-assessment experiments of influenza virus transmissibility, including disclosure of variables known or suspected to contribute to experimental variability in this model, and advocate adoption of more standardized practices. We also discuss current limitations of the ferret transmission model and highlight continued refinements and advances to this model ongoing in laboratories. Understanding, disclosing, and standardizing the critical parameters of ferret transmission studies will improve the comparability and reproducibility of pandemic influenza risk assessment and increase the statistical power and, perhaps, accuracy of this model. PMID:29774862

  4. Estimating Time-Varying PCB Exposures Using Person-Specific Predictions to Supplement Measured Values: A Comparison of Observed and Predicted Values in Two Cohorts of Norwegian Women.

    PubMed

    Nøst, Therese Haugdahl; Breivik, Knut; Wania, Frank; Rylander, Charlotta; Odland, Jon Øyvind; Sandanger, Torkjel Manning

    2016-03-01

    Studies on the health effects of polychlorinated biphenyls (PCBs) call for an understanding of past and present human exposure. Time-resolved mechanistic models may supplement information on concentrations in individuals obtained from measurements and/or statistical approaches if they can be shown to reproduce empirical data. Here, we evaluated the capability of one such mechanistic model to reproduce measured PCB concentrations in individual Norwegian women. We also assessed individual life-course concentrations. Concentrations of four PCB congeners in pregnant (n = 310, sampled in 2007-2009) and postmenopausal (n = 244, 2005) women were compared with person-specific predictions obtained using CoZMoMAN, an emission-based environmental fate and human food-chain bioaccumulation model. Person-specific predictions were also made using statistical regression models including dietary and lifestyle variables and concentrations. CoZMoMAN accurately reproduced medians and ranges of measured concentrations in the two study groups. Furthermore, rank correlations between measurements and predictions from both CoZMoMAN and regression analyses were strong (Spearman's r > 0.67). Precision in quartile assignments from predictions was strong overall as evaluated by weighted Cohen's kappa (> 0.6). Simulations indicated large inter-individual differences in concentrations experienced in the past. The mechanistic model reproduced all measurements of PCB concentrations within a factor of 10, and subject ranking and quartile assignments were overall largely consistent, although they were weak within each study group. Contamination histories for individuals predicted by CoZMoMAN revealed variation between study subjects, particularly in the timing of peak concentrations. Mechanistic models can provide individual PCB exposure metrics that could serve as valuable supplements to measurements.

  5. Validation of biomarkers of food intake-critical assessment of candidate biomarkers.

    PubMed

    Dragsted, L O; Gao, Q; Scalbert, A; Vergères, G; Kolehmainen, M; Manach, C; Brennan, L; Afman, L A; Wishart, D S; Andres Lacueva, C; Garcia-Aloy, M; Verhagen, H; Feskens, E J M; Praticò, G

    2018-01-01

    Biomarkers of food intake (BFIs) are a promising tool for limiting misclassification in nutrition research where more subjective dietary assessment instruments are used. They may also be used to assess compliance to dietary guidelines or to a dietary intervention. Biomarkers therefore hold promise for direct and objective measurement of food intake. However, the number of comprehensively validated biomarkers of food intake is limited to just a few. Many new candidate biomarkers emerge from metabolic profiling studies and from advances in food chemistry. Furthermore, candidate food intake biomarkers may also be identified based on extensive literature reviews such as described in the guidelines for Biomarker of Food Intake Reviews (BFIRev). To systematically and critically assess the validity of candidate biomarkers of food intake, it is necessary to outline and streamline an optimal and reproducible validation process. A consensus-based procedure was used to provide and evaluate a set of the most important criteria for systematic validation of BFIs. As a result, a validation procedure was developed including eight criteria, plausibility, dose-response, time-response, robustness, reliability, stability, analytical performance, and inter-laboratory reproducibility. The validation has a dual purpose: (1) to estimate the current level of validation of candidate biomarkers of food intake based on an objective and systematic approach and (2) to pinpoint which additional studies are needed to provide full validation of each candidate biomarker of food intake. This position paper on biomarker of food intake validation outlines the second step of the BFIRev procedure but may also be used as such for validation of new candidate biomarkers identified, e.g., in food metabolomic studies.

  6. Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: an in vitro study.

    PubMed

    Schaefer, Oliver; Schmidt, Monika; Goebel, Roland; Kuepper, Harald

    2012-09-01

    The accuracy of impressions has been described in 1 or 2 dimensions, whereas it is most desirable to evaluate the accuracy of impressions spatially, in 3 dimensions. The purpose of this study was to demonstrate the accuracy and reproducibility of a 3-dimensional (3-D) approach to assessing impression preciseness and to quantitatively comparing the occlusal correctness of gypsum dies made with different impression materials. By using an aluminum replica of a maxillary molar, single-step dual viscosity impressions were made with 1 polyether/vinyl polysiloxane hybrid material (Identium), 1 vinyl polysiloxane (Panasil), and 1 polyether (Impregum) (n=5). Corresponding dies were made of Type IV gypsum and were optically digitized and aligned to the virtual reference of the aluminum tooth. Accuracy was analyzed by computing mean quadratic deviations between the virtual reference and the gypsum dies, while deviations of the dies among one another determined the reproducibility of the method. The virtual reference was adapted to create 15 occlusal contact points. The percentage of contact points deviating within a ±10 µm tolerance limit (PDP(10) = Percentage of Deviating Points within ±10 µm Tolerance) was set as the index for assessing occlusal accuracy. Visual results for the difference from the reference tooth were displayed with colors, whereas mean deviation values as well as mean PDP(10) differences were analyzed with a 1-way ANOVA and Scheffé post hoc comparisons (α=.05). Objective characterization of accuracy showed smooth axial surfaces to be undersized, whereas occlusal surfaces were accurate or enlarged when compared to the original tooth. The accuracy of the gypsum replicas ranged between 3 and 6 µm, while reproducibility results varied from 2 to 4 µm. Mean (SD) PDP(10)-values were: Panasil 91% (±11), Identium 77% (±4) and Impregum 29% (±3). One-way ANOVA detected significant differences among the subjected impression materials (P<.001). The accuracy and reproducibility of impressions were determined by 3-D analysis. Results were presented as color images and the newly developed PDP(10)-index was successfully used to quantify spatial dimensions for complex occlusal anatomy. Impression materials with high PDP(10)-values were shown to reproduce occlusal dimensions the most accurately. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  7. Genotypic variability enhances the reproducibility of an ecological study.

    PubMed

    Milcu, Alexandru; Puga-Freitas, Ruben; Ellison, Aaron M; Blouin, Manuel; Scheu, Stefan; Freschet, Grégoire T; Rose, Laura; Barot, Sebastien; Cesarz, Simone; Eisenhauer, Nico; Girin, Thomas; Assandri, Davide; Bonkowski, Michael; Buchmann, Nina; Butenschoen, Olaf; Devidal, Sebastien; Gleixner, Gerd; Gessler, Arthur; Gigon, Agnès; Greiner, Anna; Grignani, Carlo; Hansart, Amandine; Kayler, Zachary; Lange, Markus; Lata, Jean-Christophe; Le Galliard, Jean-François; Lukac, Martin; Mannerheim, Neringa; Müller, Marina E H; Pando, Anne; Rotter, Paula; Scherer-Lorenzen, Michael; Seyhun, Rahme; Urban-Mead, Katherine; Weigelt, Alexandra; Zavattaro, Laura; Roy, Jacques

    2018-02-01

    Many scientific disciplines are currently experiencing a 'reproducibility crisis' because numerous scientific findings cannot be repeated consistently. A novel but controversial hypothesis postulates that stringent levels of environmental and biotic standardization in experimental studies reduce reproducibility by amplifying the impacts of laboratory-specific environmental factors not accounted for in study designs. A corollary to this hypothesis is that a deliberate introduction of controlled systematic variability (CSV) in experimental designs may lead to increased reproducibility. To test this hypothesis, we had 14 European laboratories run a simple microcosm experiment using grass (Brachypodium distachyon L.) monocultures and grass and legume (Medicago truncatula Gaertn.) mixtures. Each laboratory introduced environmental and genotypic CSV within and among replicated microcosms established in either growth chambers (with stringent control of environmental conditions) or glasshouses (with more variable environmental conditions). The introduction of genotypic CSV led to 18% lower among-laboratory variability in growth chambers, indicating increased reproducibility, but had no significant effect in glasshouses where reproducibility was generally lower. Environmental CSV had little effect on reproducibility. Although there are multiple causes for the 'reproducibility crisis', deliberately including genetic variability may be a simple solution for increasing the reproducibility of ecological studies performed under stringently controlled environmental conditions.

  8. [Reliability of a questionnaire to assess physical activity in normal weight adolescents and overweight].

    PubMed

    Gómez Campos, Rossana; de Arruda, Miguel; Camargo, Cristiane; Cossio Bolaños, Marco A

    2015-05-01

    In recent years it has reported high levels of obesity associated with low levels of physical activity, which shows the need for assessment as elements of health and quality of life. To verify the ability of reproducibility of a PA questionnaire in school adolescents classified as normal weight, overweight and obese. A descriptive cross-sectional study was conducted in 1306 adolescent students (562 men and 744 women) from three municipal educational institutions of the province of Talca (Chile). The age range was from 12.0 to 17.9 years. Weight and height were assessed and body mass index was calculated. Cutoff points used CDC-2000 for nutritional classification categories (normal weight, overweight and obesity) was used. A survey of physical activity was applied to the three groups studied. 388 men and 533 women with normal weight were identified, 131 men and 169 overweight women, 43 men and 42 women with obesity. Both sexes showed high Cronbach alpha reliability values. In men (0.80 with normal weight, overweight 0.77 and 0.83 with obesity) and women (0.79 with normal weight, overweight 0.77 and 0.76 with obesity). The instrument used showed high reproducibility capacity in both normal weight adolescents, overweight and obesity. These results suggest everyday use in survey to assess the patterns of AF scale, regardless of nutritional status in which they are located. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  9. Reproducibility of MR-Based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer.

    PubMed

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H; Keller, Sune H; Löfgren, Johan; Hansen, Adam E; Kjær, Andreas; Langer, Seppo W; Fischer, Barbara M; Andersen, Flemming L

    2018-06-01

    Quantitative PET/MRI is dependent on reliable and reproducible MR-based attenuation correction (MR-AC). In this study, we evaluated the quality of current vendor-provided thoracic MR-AC maps and further investigated the reproducibility of their impact on 18 F-FDG PET quantification in patients with non-small cell lung cancer. Methods: Eleven patients with inoperable non-small cell lung cancer underwent 2-5 thoracic PET/MRI scan-rescan examinations within 22 d. 18 F-FDG PET data were acquired along with 2 Dixon MR-AC maps for each examination. Two PET images (PET A and PET B ) were reconstructed using identical PET emission data but with MR-AC from these intrasubject repeated attenuation maps. In total, 90 MR-AC maps were evaluated visually for quality and the occurrence of categorized artifacts by 2 PET/MRI-experienced physicians. Each tumor was outlined by a volume of interest (40% isocontour of maximum) on PET A , which was then projected onto the corresponding PET B SUV mean and SUV max were assessed from the PET images. Within-examination coefficients of variation and Bland-Altman analyses were conducted for the assessment of SUV variations between PET A and PET B Results: Image artifacts were observed in 86% of the MR-AC maps, and 30% of the MR-AC maps were subjectively expected to affect the tumor SUV. SUV mean and SUV max resulted in coefficients of variation of 5.6% and 6.6%, respectively, and scan-rescan SUV variations were within ±20% in 95% of the cases. Substantial SUV variations were seen mainly for scan-rescan examinations affected by respiratory motion. Conclusion: Artifacts occur frequently in standard thoracic MR-AC maps, affecting the reproducibility of PET/MRI. These, in combination with other well-known sources of error associated with PET/MRI examinations, lead to inconsistent SUV measurements in serial studies, which may affect the reliability of therapy response assessment. A thorough visual inspection of the thoracic MR-AC map and Dixon images from which it is derived remains crucial for the detection of MR-AC artifacts that may influence the reliability of SUV. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  10. HiC-bench: comprehensive and reproducible Hi-C data analysis designed for parameter exploration and benchmarking.

    PubMed

    Lazaris, Charalampos; Kelly, Stephen; Ntziachristos, Panagiotis; Aifantis, Iannis; Tsirigos, Aristotelis

    2017-01-05

    Chromatin conformation capture techniques have evolved rapidly over the last few years and have provided new insights into genome organization at an unprecedented resolution. Analysis of Hi-C data is complex and computationally intensive involving multiple tasks and requiring robust quality assessment. This has led to the development of several tools and methods for processing Hi-C data. However, most of the existing tools do not cover all aspects of the analysis and only offer few quality assessment options. Additionally, availability of a multitude of tools makes scientists wonder how these tools and associated parameters can be optimally used, and how potential discrepancies can be interpreted and resolved. Most importantly, investigators need to be ensured that slight changes in parameters and/or methods do not affect the conclusions of their studies. To address these issues (compare, explore and reproduce), we introduce HiC-bench, a configurable computational platform for comprehensive and reproducible analysis of Hi-C sequencing data. HiC-bench performs all common Hi-C analysis tasks, such as alignment, filtering, contact matrix generation and normalization, identification of topological domains, scoring and annotation of specific interactions using both published tools and our own. We have also embedded various tasks that perform quality assessment and visualization. HiC-bench is implemented as a data flow platform with an emphasis on analysis reproducibility. Additionally, the user can readily perform parameter exploration and comparison of different tools in a combinatorial manner that takes into account all desired parameter settings in each pipeline task. This unique feature facilitates the design and execution of complex benchmark studies that may involve combinations of multiple tool/parameter choices in each step of the analysis. To demonstrate the usefulness of our platform, we performed a comprehensive benchmark of existing and new TAD callers exploring different matrix correction methods, parameter settings and sequencing depths. Users can extend our pipeline by adding more tools as they become available. HiC-bench consists an easy-to-use and extensible platform for comprehensive analysis of Hi-C datasets. We expect that it will facilitate current analyses and help scientists formulate and test new hypotheses in the field of three-dimensional genome organization.

  11. Utilization of MRI for Cerebral White Matter Injury in a Hypobaric Swine Model-Validation of Technique

    DTIC Science & Technology

    2017-05-23

    study demonstrates high reproducibility of quantitative noninvasive MRI, suggesting MRI is an appropriate assessment tool for TBI and hypobaric-induced...propofol/ketamine adjusted to maintain stable physiological parameters and anesthesia. On study day 1, baseline imaging was performed. Exposure episodes...began on study day 3 with three subject animals exposed six times to 9,144 meters (ascent/descent time 15 minutes) over 12 days, one exposed five times

  12. New approach to weight-of-evidence assessment of ecotoxicological effects in regulatory decision-making.

    PubMed

    Hall, A Tilghman; Belanger, Scott E; Guiney, Pat D; Galay-Burgos, Malyka; Maack, Gerd; Stubblefield, William; Martin, Olwenn

    2017-07-01

    Ecological risk assessments and risk management decisions are only as sound as the underlying information and processes to integrate them. It is important to develop transparent and reproducible procedures a priori to integrate often-heterogeneous evidence. Current weight-of-evidence (WoE) approaches for effects or hazard assessment tend to conflate aspects of the assessment of the quality of the data with the strength of the body of evidence as a whole. We take forward recent developments in the critical appraisal of the reliability and relevance of individual ecotoxicological studies as part of the effect or hazard assessment of prospective risk assessments and propose a streamlined WoE approach. The aim is to avoid overlap and double accounting of criteria used in reliability and relevance with that used in current WoE methods. The protection goals, problem formulation, and evaluation process need to be clarified at the outset. The data are first integrated according to lines of evidence (LoEs), typically mechanistic insights (e.g., cellular, subcellular, genomic), in vivo experiments, and higher-tiered field or observational studies. Data are then plotted on the basis of both relevance and reliability scores or categories. This graphical approach provides a means to visually assess and communicate the credibility (reliability and relevance of available individual studies), quantity, diversity, and consistency of the evidence. In addition, the external coherence of the body of evidence needs to be considered. The final step in the process is to derive an expression of the confidence in the conclusions of integrating the information considering these 5 aspects in the context of remaining uncertainties. We suggest that this streamlined approach to WoE for the effects or hazard characterization should facilitate reproducible and transparent assessments of data across different regulatory requirements. Integr Environ Assess Manag 2017;13:573-579. © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  13. Durable Hybrid Coatings

    DTIC Science & Technology

    2007-10-01

    Freeman 1998). The concept of molecular FV and its relationship to a multiplicity of properties in materials has been discussed for decades. For...importance of FV and developed theoretical relationships without being able to accurately and directly measure it. Dilatometry, diffusion studies with an...found to decrease with increase oligomeric triol molecular weight . PAS was conducted on free films. In order to assess reproducibility, measurements

  14. A Comparison of Lung Nodule Segmentation Algorithms: Methods and Results from a Multi-institutional Study.

    PubMed

    Kalpathy-Cramer, Jayashree; Zhao, Binsheng; Goldgof, Dmitry; Gu, Yuhua; Wang, Xingwei; Yang, Hao; Tan, Yongqiang; Gillies, Robert; Napel, Sandy

    2016-08-01

    Tumor volume estimation, as well as accurate and reproducible borders segmentation in medical images, are important in the diagnosis, staging, and assessment of response to cancer therapy. The goal of this study was to demonstrate the feasibility of a multi-institutional effort to assess the repeatability and reproducibility of nodule borders and volume estimate bias of computerized segmentation algorithms in CT images of lung cancer, and to provide results from such a study. The dataset used for this evaluation consisted of 52 tumors in 41 CT volumes (40 patient datasets and 1 dataset containing scans of 12 phantom nodules of known volume) from five collections available in The Cancer Imaging Archive. Three academic institutions developing lung nodule segmentation algorithms submitted results for three repeat runs for each of the nodules. We compared the performance of lung nodule segmentation algorithms by assessing several measurements of spatial overlap and volume measurement. Nodule sizes varied from 29 μl to 66 ml and demonstrated a diversity of shapes. Agreement in spatial overlap of segmentations was significantly higher for multiple runs of the same algorithm than between segmentations generated by different algorithms (p < 0.05) and was significantly higher on the phantom dataset compared to the other datasets (p < 0.05). Algorithms differed significantly in the bias of the measured volumes of the phantom nodules (p < 0.05) underscoring the need for assessing performance on clinical data in addition to phantoms. Algorithms that most accurately estimated nodule volumes were not the most repeatable, emphasizing the need to evaluate both their accuracy and precision. There were considerable differences between algorithms, especially in a subset of heterogeneous nodules, underscoring the recommendation that the same software be used at all time points in longitudinal studies.

  15. Stability and reproducibility of proteomic profiles measured with an aptamer-based platform.

    PubMed

    Kim, Claire H; Tworoger, Shelley S; Stampfer, Meir J; Dillon, Simon T; Gu, Xuesong; Sawyer, Sherilyn J; Chan, Andrew T; Libermann, Towia A; Eliassen, A Heather

    2018-05-30

    The feasibility of SOMAscan, a multiplex, high sensitivity proteomics platform, for use in studies using archived plasma samples has not yet been assessed. We quantified 1,305 proteins from plasma samples donated by 16 Nurses' Health Study (NHS) participants, 40 NHSII participants, and 12 local volunteers. We assessed assay reproducibility using coefficients of variation (CV) from duplicate samples and intra-class correlation coefficients (ICC) and Spearman correlation coefficients (r) of samples processed (i.e., centrifuged and aliquoted into separate components) immediately, 24, and 48 hours after collection, as well as those of samples collected from the same individuals 1 year apart. CVs were <20% for 99% of proteins overall and <10% for 92% of proteins in heparin samples compared to 66% for EDTA samples. We observed ICC or Spearman r (comparing immediate vs. 24-hour delayed processing) ≥0.75 for 61% of proteins, with some variation by anticoagulant (56% for heparin and 70% for EDTA) and protein class (ranging from 49% among kinases to 83% among hormones). Within-person stability over 1 year was good (ICC or Spearman r ≥ 0.4) for 91% of proteins. These results demonstrate the feasibility of SOMAscan for analyses of archived plasma samples.

  16. Updating source term and atmospheric dispersion simulations for the dose reconstruction in Fukushima Daiichi Nuclear Power Station Accident

    NASA Astrophysics Data System (ADS)

    Nagai, Haruyasu; Terada, Hiroaki; Tsuduki, Katsunori; Katata, Genki; Ota, Masakazu; Furuno, Akiko; Akari, Shusaku

    2017-09-01

    In order to assess the radiological dose to the public resulting from the Fukushima Daiichi Nuclear Power Station (FDNPS) accident in Japan, especially for the early phase of the accident when no measured data are available for that purpose, the spatial and temporal distribution of radioactive materials in the environment are reconstructed by computer simulations. In this study, by refining the source term of radioactive materials discharged into the atmosphere and modifying the atmospheric transport, dispersion and deposition model (ATDM), the atmospheric dispersion simulation of radioactive materials is improved. Then, a database of spatiotemporal distribution of radioactive materials in the air and on the ground surface is developed from the output of the simulation. This database is used in other studies for the dose assessment by coupling with the behavioral pattern of evacuees from the FDNPS accident. By the improvement of the ATDM simulation to use a new meteorological model and sophisticated deposition scheme, the ATDM simulations reproduced well the 137Cs and 131I deposition patterns. For the better reproducibility of dispersion processes, further refinement of the source term was carried out by optimizing it to the improved ATDM simulation by using new monitoring data.

  17. Short- and long-term quantitation reproducibility of brain metabolites in the medial wall using proton echo planar spectroscopic imaging.

    PubMed

    Tsai, Shang-Yueh; Lin, Yi-Ru; Wang, Woan-Chyi; Niddam, David M

    2012-11-15

    Proton echo planar spectroscopic imaging (PEPSI) is a fast magnetic resonance spectroscopic imaging (MRSI) technique that allows mapping spatial metabolite distributions in the brain. Although the medial wall of the cortex is involved in a wide range of pathological conditions, previous MRSI studies have not focused on this region. To decide the magnitude of metabolic changes to be considered significant in this region, the reproducibility of the method needs to be established. The study aims were to establish the short- and long-term reproducibility of metabolites in the right medial wall and to compare regional differences using a constant short-echo time (TE30) and TE averaging (TEavg) optimized to yield glutamatergic information. 2D sagittal PEPSI was implemented at 3T using a 32 channel head coil. Acquisitions were repeated immediately and after approximately 2 weeks to assess the coefficients of variation (COV). COVs were obtained from eight regions-of-interest (ROIs) of varying size and location. TE30 resulted in better spectral quality and similar or lower quantitation uncertainty for all metabolites except glutamate (Glu). When Glu and glutamine (Gln) were quantified together (Glx) reduced quantitation uncertainty and increased reproducibility was observed for TE30. TEavg resulted in lowered quantitation uncertainty for Glu but in less reliable quantification of several other metabolites. TEavg did not result in a systematically improved short- or long-term reproducibility for Glu. The ROI volume was a major factor influencing reproducibility. For both short- and long-term repetitions, the Glu COVs obtained with TEavg were 5-8% for the large ROIs, 12-17% for the medium sized ROIs and 16-26% for the smaller cingulate ROIs. COVs obtained with TE30 for the less specific Glx were 3-5%, 8-10% and 10-15%. COVs for N-acetyl aspartate, creatine and choline using TE30 with long-term repetition were between 2-10%. Our results show that the cost of more specific glutamatergic information (Glu versus Glx) is the requirement of an increased effect size especially with increasing anatomical specificity. This comes in addition to the loss of sensitivity for other metabolites. Encouraging results were obtained with TE30 compared to other previously reported MRSI studies. The protocols implemented here are reliable and may be used to study disease progression and intervention mechanisms. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. A review of the reporting of web searching to identify studies for Cochrane systematic reviews.

    PubMed

    Briscoe, Simon

    2018-03-01

    The literature searches that are used to identify studies for inclusion in a systematic review should be comprehensively reported. This ensures that the literature searches are transparent and reproducible, which is important for assessing the strengths and weaknesses of a systematic review and re-running the literature searches when conducting an update review. Web searching using search engines and the websites of topically relevant organisations is sometimes used as a supplementary literature search method. Previous research has shown that the reporting of web searching in systematic reviews often lacks important details and is thus not transparent or reproducible. Useful details to report about web searching include the name of the search engine or website, the URL, the date searched, the search strategy, and the number of results. This study reviews the reporting of web searching to identify studies for Cochrane systematic reviews published in the 6-month period August 2016 to January 2017 (n = 423). Of these reviews, 61 reviews reported using web searching using a search engine or website as a literature search method. In the majority of reviews, the reporting of web searching was found to lack essential detail for ensuring transparency and reproducibility, such as the search terms. Recommendations are made on how to improve the reporting of web searching in Cochrane systematic reviews. Copyright © 2017 John Wiley & Sons, Ltd.

  19. ProtocolNavigator: emulation-based software for the design, documentation and reproduction biological experiments.

    PubMed

    Khan, Imtiaz A; Fraser, Adam; Bray, Mark-Anthony; Smith, Paul J; White, Nick S; Carpenter, Anne E; Errington, Rachel J

    2014-12-01

    Experimental reproducibility is fundamental to the progress of science. Irreproducible research decreases the efficiency of basic biological research and drug discovery and impedes experimental data reuse. A major contributing factor to irreproducibility is difficulty in interpreting complex experimental methodologies and designs from written text and in assessing variations among different experiments. Current bioinformatics initiatives either are focused on computational research reproducibility (i.e. data analysis) or laboratory information management systems. Here, we present a software tool, ProtocolNavigator, which addresses the largely overlooked challenges of interpretation and assessment. It provides a biologist-friendly open-source emulation-based tool for designing, documenting and reproducing biological experiments. ProtocolNavigator was implemented in Python 2.7, using the wx module to build the graphical user interface. It is a platform-independent software and freely available from http://protocolnavigator.org/index.html under the GPL v2 license. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Statistical Issues in the Comparison of Quantitative Imaging Biomarker Algorithms using Pulmonary Nodule Volume as an Example

    PubMed Central

    2014-01-01

    Quantitative imaging biomarkers (QIBs) are being used increasingly in medicine to diagnose and monitor patients’ disease. The computer algorithms that measure QIBs have different technical performance characteristics. In this paper we illustrate the appropriate statistical methods for assessing and comparing the bias, precision, and agreement of computer algorithms. We use data from three studies of pulmonary nodules. The first study is a small phantom study used to illustrate metrics for assessing repeatability. The second study is a large phantom study allowing assessment of four algorithms’ bias and reproducibility for measuring tumor volume and the change in tumor volume. The third study is a small clinical study of patients whose tumors were measured on two occasions. This study allows a direct assessment of six algorithms’ performance for measuring tumor change. With these three examples we compare and contrast study designs and performance metrics, and we illustrate the advantages and limitations of various common statistical methods for QIB studies. PMID:24919828

  1. A method to calculate the volume of palatine tonsils.

    PubMed

    Prim, M P; De Diego, J I; García-Bermúdez, C; Pérez-Fernández, E; Hardisson, D

    2010-12-01

    The purpose of this study was to obtain a mathematical formula to calculate the tonsillar volume out of its measurements assessed on surgical specimens. Thirty consecutive surgical specimens of pediatric tonsils were studied. The maximum lengths ("a"), widths ("b"), and depths ("c") of the dissected specimens were measured in millimeters, and the volume of each tonsil was measured in milliliters. One-sample Kolmogorov-Smirnov test was used to check the normality of the sample. To calculate the reproducibility of the quantitative variables, intraclass correlation coefficients were used. Two formulas with high reproducibility (coefficient R between 0.75 and 1) were obtained: 1) [a*b*c* 0.5236] with R = 0.8688; and 2) [a*b*b* 0.3428] with R = 0.9073. It is possible to calculate the volume of the palatine tonsils in surgical specimens precisely enough based on their three measures, or their two main measures (length and width).

  2. Research Reproducibility in Geosciences: Current Landscape, Practices and Perspectives

    NASA Astrophysics Data System (ADS)

    Yan, An

    2016-04-01

    Reproducibility of research can gauge the validity of its findings. Yet currently we lack understanding of how much of a problem research reproducibility is in geosciences. We developed an online survey on faculty and graduate students in geosciences, and received 136 responses from research institutions and universities in Americas, Asia, Europe and other parts of the world. This survey examined (1) the current state of research reproducibility in geosciences by asking researchers' experiences with unsuccessful replication work, and what obstacles that lead to their replication failures; (2) the current reproducibility practices in community by asking what efforts researchers made to try to reproduce other's work and make their own work reproducible, and what the underlying factors that contribute to irreproducibility are; (3) the perspectives on reproducibility by collecting researcher's thoughts and opinions on this issue. The survey result indicated that nearly 80% of respondents who had ever reproduced a published study had failed at least one time in reproducing. Only one third of the respondents received helpful feedbacks when they contacted the authors of a published study for data, code, or other information. The primary factors that lead to unsuccessful replication attempts are insufficient details of instructions in published literature, and inaccessibility of data, code and tools needed in the study. Our findings suggest a remarkable lack of research reproducibility in geoscience. Changing the incentive mechanism in academia, as well as developing policies and tools that facilitate open data and code sharing are the promising ways for geosciences community to alleviate this reproducibility problem.

  3. Actinic cheilitis: proposition and reproducibility of a clinical criterion

    PubMed Central

    Poitevin, Nádia Antunes; Rodrigues, Mariana Sudati; Weigert, Karen Loureiro; Macedo, Carmen Lúcia Rodrigues; dos Santos, Rubem Beraldo

    2017-01-01

    Objectives/Aims: The actinic cheilitis (AC) is a precancerous lip lesion seen as a consequence of chronic sun exposure. Clinically, the border between the lip’s skin and the semimucosa could be blurred; in the more aggressive cases, leucoplakia and ulcers also represent its clinical feature. It seems that no clinical criterion is universally accepted for this disease yet. Therefore, this study was carried out to make a proposition of a clinical score to actinic cheilitis (Grade I starting from dryness of vermilion to endured ulcers representing Grade IV) and to assess its reproducibility. Materials and Methods: Fifty subjects were assessed, most of whom were male, Caucasian farmers, with an average age of 46.12 (18–74) years. The obtained data were analysed by means of descriptive statistics and by Kappa test to assess the inter-examiners and the clinical Golden-Pattern concordance (95% CI). Results: During calibration, 15 patients were examined three times a week by each examiner (4) until Kappa test observed k=0.8 or more. In the main experiment, the inter-examiner concordance was classified between good (k=0.779; P<0.05) and very good (k=0.925; P<0.05) from the 35 examined subjects. With the Golden-Pattern, it was considered very good (k=0.812; P<0.05 to k=0.925; P<0.05). Discussion: Four examiners with different experiences could strongly suggest that after adequate calibration, it could be well applied by examiners with as much experience as a dental student. Conclusions: The authors concluded that the proposed classification was easily applied and had a very good reproducibility. PMID:29607086

  4. Translational aspects of rectal evoked potentials: a comparative study in rats and humans

    PubMed Central

    Nissen, Thomas Dahl; Graversen, Carina; Coen, Steven J.; Hultin, Leif; Aziz, Qasim; Lykkesfeldt, Jens; Drewes, Asbjørn Mohr

    2013-01-01

    Inconsistencies between species has stunted the progress of developing new analgesics. To increase the success of translating results between species, improved comparable models are required. Twelve rats received rectal balloon distensions on 2 different days separated by 24.3 (SD 24.6) days. Rectal balloon distensions were also performed in 18 humans (mean age: 34 yr; range: 21–56 yr; 12 men) on two separate occasions, separated by 9.3 (SD 5.5) days. In rats, cerebral evoked potentials (CEPs) were recorded by use of implanted skull-electrodes to distension pressure of 80 mmHg. In humans surface electrodes and individualized pressure, corresponding to pain detection threshold, were used. Comparison of morphology was assessed by wavelet analysis. Within- and between-day reproducibility was assessed in terms of latencies, amplitudes, and frequency content. In rats CEPs showed triphasic morphology. No differences in latencies, amplitudes, and power distribution were seen within or between days (all P ≥ 0.5). Peak-to-peak amplitude between the first positive and negative potential were the most reproducible characteristic within and between days (evaluated by intraclass correlation coefficients, ICC) (ICC = 0.99 and ICC = 9.98, respectively). In humans CEPs showed a triphasic morphology. No differences in latencies, amplitudes, or power distribution were seen within or between days (all P ≥ 0.2). Latency to the second negative potential (ICC = 0.98) and the second positive potential (ICC = 0.95) was the most reproducible characteristic within and between days. A unique and reliable translational platform was established assessing visceral sensitivity in rats and humans, which may improve the translational process of developing new drugs targeting visceral pain. PMID:23703652

  5. Usefulness of 3-Tesla cardiac magnetic resonance imaging in the assessment of aortic stenosis severity in routine clinical practice.

    PubMed

    Levy, Franck; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carine; Hugues, Nicolas; Alexandrescu, Clara; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2016-11-01

    Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context. To evaluate the feasibility and reproducibility of the assessment of aortic valve area (AVA) using 3-Tesla CMR in routine clinical practice, and to assess concordance between TTE and CMR for the estimation of AS severity. Ninety-one consecutive patients (60 men; mean age 74±10years) with known AS documented by TTE were included prospectively in the study. All patients underwent comprehensive TTE and CMR examination, including AVA estimation using the TTE continuity equation (0.81±0.18cm 2 ), direct CMR planimetry (CMRp) (0.90±0.22cm 2 ) and CMR using Hakki's formula (CMRhk), a simplified Gorlin formula (0.70±0.19cm 2 ). Although significant agreement with TTE was found for CMRp (r=0.72) and CMRhk (r=0.66), CMRp slightly overestimated (bias=0.11±0.18cm 2 ) and CMRhk slightly underestimated (bias=-0.11±0.17cm 2 ) AVA compared with TTE. Inter- and intraobserver reproducibilities of CMR measurements were excellent (r=0.72 and r=0.74 for CMRp and r=0.88 and r=0.92 for peak aortic velocity, respectively). 3-Tesla CMR is a feasible, radiation-free, reproducible imaging modality for the estimation of severity of AS in routine practice, knowing that CMRp tends to overestimate AVA and CMRhk to underestimate AVA compared with TTE. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography

    PubMed Central

    Smith, Michael; Frost, Andrew; Graham, Christopher Mark; Shaw, Steven

    2007-01-01

    Aims To examine the effect of pupillary dilatation on the reliability of retinal nerve fibre layer (RNFL) and optic nerve head (ONH) assessments using Stratus OCT in a glaucoma clinic. Methods Observational study of 38 patients attending a glaucoma clinic. The “fast optic disc” and “fast RNFL thickness” programs on Stratus OCT were used to measure the RNFL thickness and ONH cup to disc ratio (CDR). Two scans were done before dilatation and two after dilatation with tropicamide 1% drops. The mean values and reproducibility before and after dilatation were compared, along with the quality of scans as indicated by the “signal strength” score. Results In nine patients (23.7%) no images were obtained undilated but after dilatation examination was possible in all patients. Inability to obtain an undilated scan was associated with smaller pupil size and increasing cataract. The scan quality, as judged by the signal strength score, was higher dilated than undilated for both RNFL thickness (p = 0.011) and ONH CDR (p = 0.007). Reproducibility was higher with dilated scans for RNFL thickness but not for ONH CDR. There were significant differences between the dilated and undilated examinations for three of the five RNFL thickness variables and two of the three ONH CDR categories. Conclusions Acquisition of high quality OCT images was not possible without pupillary dilatation in about 25% of the patients. The dilated scans were more reproducible and of higher quality than the undilated scans. The two methods of examination do not appear to be interchangeable, suggesting that in follow up examinations the pupil should be in the same condition as at baseline. Pupillary dilatation is recommended before glaucoma assessments using Stratus OCT. PMID:17556429

  7. IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T

    PubMed Central

    Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir

    2015-01-01

    Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236

  8. Reliability, repeatability, and reproducibility of pulmonary transit time assessment by contrast enhanced echocardiography.

    PubMed

    Herold, Ingeborg H F; Saporito, Salvatore; Bouwman, R Arthur; Houthuizen, Patrick; van Assen, Hans C; Mischi, Massimo; Korsten, Hendrikus H M

    2016-01-05

    The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.

  9. Quantification of early cutaneous manifestations of chronic venous insufficiency by automated analysis of photographic images: Feasibility and technical considerations.

    PubMed

    Becker, François; Fourgeau, Patrice; Carpentier, Patrick H; Ouchène, Amina

    2018-06-01

    We postulate that blue telangiectasia and brownish pigmentation at ankle level, early markers of chronic venous insufficiency, can be quantified for longitudinal studies of chronic venous disease in Caucasian people. Objectives and methods To describe a photographic technique specially developed for this purpose. The pictures were acquired using a dedicated photo stand to position the foot in a reproducible way, with a normalized lighting and acquisition protocol. The image analysis was performed with a tool developed using algorithms optimized to detect and quantify blue telangiectasia and brownish pigmentation and their relative surface in the region of interest. To test the short-term reproducibility of the measures. Results The quantification of the blue telangiectasia and of the brownish pigmentation using an automated digital photo analysis is feasible. The short-term reproducibility is good for blue telangiectasia quantification. It is a less accurate for the brownish pigmentation. Conclusion The blue telangiectasia of the corona phlebectatica and the ankle flare can be assessed using a clinimetric approach based on the automated digital photo analysis.

  10. Spotting and validation of a genome wide oligonucleotide chip with duplicate measurement of each gene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomassen, Mads; Skov, Vibe; Eiriksdottir, Freyja

    2006-06-16

    The quality of DNA microarray based gene expression data relies on the reproducibility of several steps in a microarray experiment. We have developed a spotted genome wide microarray chip with oligonucleotides printed in duplicate in order to minimise undesirable biases, thereby optimising detection of true differential expression. The validation study design consisted of an assessment of the microarray chip performance using the MessageAmp and FairPlay labelling kits. Intraclass correlation coefficient (ICC) was used to demonstrate that MessageAmp was significantly more reproducible than FairPlay. Further examinations with MessageAmp revealed the applicability of the system. The linear range of the chips wasmore » three orders of magnitude, the precision was high, as 95% of measurements deviated less than 1.24-fold from the expected value, and the coefficient of variation for relative expression was 13.6%. Relative quantitation was more reproducible than absolute quantitation and substantial reduction of variance was attained with duplicate spotting. An analysis of variance (ANOVA) demonstrated no significant day-to-day variation.« less

  11. Using simulated fluorescence cell micrographs for the evaluation of cell image segmentation algorithms.

    PubMed

    Wiesmann, Veit; Bergler, Matthias; Palmisano, Ralf; Prinzen, Martin; Franz, Daniela; Wittenberg, Thomas

    2017-03-18

    Manual assessment and evaluation of fluorescent micrograph cell experiments is time-consuming and tedious. Automated segmentation pipelines can ensure efficient and reproducible evaluation and analysis with constant high quality for all images of an experiment. Such cell segmentation approaches are usually validated and rated in comparison to manually annotated micrographs. Nevertheless, manual annotations are prone to errors and display inter- and intra-observer variability which influence the validation results of automated cell segmentation pipelines. We present a new approach to simulate fluorescent cell micrographs that provides an objective ground truth for the validation of cell segmentation methods. The cell simulation was evaluated twofold: (1) An expert observer study shows that the proposed approach generates realistic fluorescent cell micrograph simulations. (2) An automated segmentation pipeline on the simulated fluorescent cell micrographs reproduces segmentation performances of that pipeline on real fluorescent cell micrographs. The proposed simulation approach produces realistic fluorescent cell micrographs with corresponding ground truth. The simulated data is suited to evaluate image segmentation pipelines more efficiently and reproducibly than it is possible on manually annotated real micrographs.

  12. Different modelling approaches to evaluate nitrogen transport and turnover at the watershed scale

    NASA Astrophysics Data System (ADS)

    Epelde, Ane Miren; Antiguedad, Iñaki; Brito, David; Jauch, Eduardo; Neves, Ramiro; Garneau, Cyril; Sauvage, Sabine; Sánchez-Pérez, José Miguel

    2016-08-01

    This study presents the simulation of hydrological processes and nutrient transport and turnover processes using two integrated numerical models: Soil and Water Assessment Tool (SWAT) (Arnold et al., 1998), an empirical and semi-distributed numerical model; and Modelo Hidrodinâmico (MOHID) (Neves, 1985), a physics-based and fully distributed numerical model. This work shows that both models reproduce satisfactorily water and nitrate exportation at the watershed scale at annual and daily basis, MOHID providing slightly better results. At the watershed scale, both SWAT and MOHID simulated similarly and satisfactorily the denitrification amount. However, as MOHID numerical model was the only one able to reproduce adequately the spatial variation of the soil hydrological conditions and water table level fluctuation, it proved to be the only model able of reproducing the spatial variation of the nutrient cycling processes that are dependent to the soil hydrological conditions such as the denitrification process. This evidences the strength of the fully distributed and physics-based models to simulate the spatial variability of nutrient cycling processes that are dependent to the hydrological conditions of the soils.

  13. Dynamic microbubble contrast-enhanced US to measure tumor response to targeted therapy: a proposed clinical protocol with results from renal cell carcinoma patients receiving antiangiogenic therapy.

    PubMed

    Williams, Ross; Hudson, John M; Lloyd, Brendan A; Sureshkumar, Ahthavan R; Lueck, Gordon; Milot, Laurent; Atri, Mostafa; Bjarnason, Georg A; Burns, Peter N

    2011-08-01

    To develop and implement an evidence-based protocol for characterizing vascular response of renal cell carcinoma (RCC) to targeted therapy by using dynamic contrast material-enhanced (DCE) ultrasonography (US). The study was approved by the institutional research ethics board; written informed consent was obtained from all patients. Seventeen patients (four women; median age, 58 years; range, 42-72 years; 13 men, median age, 62 years; range, 45-81 years) with metastatic RCC were examined by using DCE US before and after 2 weeks of treatment with sunitinib (May 2007 to October 2009). Two contrast agent techniques--bolus injection and disruption-replenishment infusion of microbubbles--were compared. Changes in tumor blood velocity and fractional blood volume were measured with both methods, together with reproducibility and effect of compensation for respiratory motion. Tumor changes were assessed with computed tomography, by using the best response with the Response Evaluation Criteria in Solid Tumors (RECIST) and progression-free survival (PFS). Follow-up RECIST measurements were performed at 6-week intervals until progressive disease was detected. In response to treatment, median tumor fractional blood volume measured with the disruption-replenishment infusion method decreased by 73.2% (interquartile range, 46%-87%) (P < .002), with repeated-measure reproducibility of 9%-15%. Significant decreases were also seen with the bolus method, but with poor correlation of changes in bolus peak (r = 0.46, P = .066) and area under the curve (r = 0.47, P = .058), compared with infusion measurements. Changes in DCE US parameters over 2 weeks did not correlate with PFS and could not be used to predict long-term assessment of best response by using RECIST. Follow-up times ranged 28-501 days; the median was 164 days. DCE US provides reproducible and sensitive assessment of vascular changes in response to antiangiogenic therapy. The disruption-replenishment infusion protocol is a flexible method suitable for many tumor types, but further studies are needed to assess whether this protocol may be predictive of patient outcome. © RSNA, 2011.

  14. In vitro performance of DIAGNOdent laser fluorescence device for dental calculus detection on human tooth root surfaces.

    PubMed

    Rams, Thomas E; Alwaqyan, Abdulaziz Y

    2017-10-01

    This study assessed the reproducibility of a red diode laser device, and its capability to detect dental calculus in vitro on human tooth root surfaces. On each of 50 extracted teeth, a calculus-positive and calculus-free root surface was evaluated by two independent examiners with a low-power indium gallium arsenide phosphide diode laser (DIAGNOdent) fitted with a periodontal probe-like sapphire tip and emitting visible red light at 655 nm wavelength. Laser autofluorescence intensity readings of examined root surfaces were scored on a 0-99 scale, with duplicate assessments performed using the laser probe tip directed both perpendicular and parallel to evaluated tooth root surfaces. Pearson correlation coefficients of untransformed measurements, and kappa analysis of data dichotomized with a >40 autofluorescence intensity threshold, were calculated to assess intra- and inter-examiner reproducibility of the laser device. Mean autofluorescence intensity scores of calculus-positive and calculus-free root surfaces were evaluated with the Student's t -test. Excellent intra- and inter-examiner reproducibility was found for DIAGNOdent laser autofluorescence intensity measurements, with Pearson correlation coefficients above 94%, and kappa values ranging between 0.96 and 1.0, for duplicate readings taken with both laser probe tip orientations. Significantly higher autofluorescence intensity values were measured when the laser probe tip was directed perpendicular, rather than parallel, to tooth root surfaces. However, calculus-positive roots, particularly with calculus in markedly-raised ledges, yielded significantly greater mean DIAGNOdent laser autofluorescence intensity scores than calculus-free surfaces, regardless of probe tip orientation. DIAGNOdent autofluorescence intensity values >40 exhibited a stronger association with calculus (36.6 odds ratio) then measurements of ≥5 (20.1 odds ratio) when the laser probe tip was advanced parallel to root surfaces. Excellent intra- and inter-examiner reproducibility of autofluorescence intensity measurements was obtained with the DIAGNOdent laser fluorescence device on human tooth roots. Calculus-positive root surfaces exhibited significantly greater DIAGNOdent laser autofluorescence than calculus-free tooth roots, even with the laser probe tip directed parallel to root surfaces. These findings provide further in vitro validation of the potential utility of a DIAGNOdent laser fluorescence device for identifying dental calculus on human tooth root surfaces.

  15. Uncertainty analysis of atmospheric deposition simulation of radiocesium and radioiodine from Fukushima Daiichi Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Morino, Yu; Ohara, Toshimasa; Yumimoto, Keiya

    2014-05-01

    Chemical transport models (CTM) played key roles in understanding the atmospheric behaviors and deposition patterns of radioactive materials emitted from the Fukushima Daiichi nuclear power plant (FDNPP) after the nuclear accident that accompanied the great Tohoku earthquake and tsunami on 11 March 2011. In this study, we assessed uncertainties of atmospheric simulation by comparing observed and simulated deposition of radiocesium (137Cs) and radioiodine (131I). Airborne monitoring survey data were used to assess the model performance of 137Cs deposition patterns. We found that simulation using emissions estimated with a regional-scale (~500 km) CTM better reproduced the observed 137Cs deposition pattern in eastern Japan than simulation using emissions estimated with local-scale (~50 km) or global-scale CTM. In addition, we estimated the emission amount of 137Cs from FDNPP by combining a CTM, a priori source term, and observed deposition data. This is the first use of airborne survey data of 137Cs deposition (more than 16,000 data points) as the observational constraints in inverse modeling. The model simulation driven by a posteriori source term achieved better agreements with 137Cs depositions measured by aircraft survey and at in-situ stations over eastern Japan. Wet deposition module was also evaluated. Simulation using a process-based wet deposition module reproduced the observations well, whereas simulation using scavenging coefficients showed large uncertainties associated with empirical parameters. The best-available simulation reproduced the observed 137Cs deposition rates in high-deposition areas (≥10 kBq m-2) within one order of magnitude. Recently, 131I deposition map was released and helped to evaluate model performance of 131I deposition patterns. Observed 131I/137Cs deposition ratio is higher in areas southwest of FDNPP than northwest of FDNPP, and this behavior was roughly reproduced by a CTM if we assume that released 131I is more in gas phase than particles. Analysis of 131I deposition gives us better constraint for the atmospheric simulation of 131I, which is important in assessing public radiation exposure.

  16. Gastropod shell size and architecture influence the applicability of methods used to estimate internal volume.

    PubMed

    Ragagnin, Marilia Nagata; Gorman, Daniel; McCarthy, Ian Donald; Sant'Anna, Bruno Sampaio; de Castro, Cláudio Campi; Turra, Alexander

    2018-01-11

    Obtaining accurate and reproducible estimates of internal shell volume is a vital requirement for studies into the ecology of a range of shell-occupying organisms, including hermit crabs. Shell internal volume is usually estimated by filling the shell cavity with water or sand, however, there has been no systematic assessment of the reliability of these methods and moreover no comparison with modern alternatives, e.g., computed tomography (CT). This study undertakes the first assessment of the measurement reproducibility of three contrasting approaches across a spectrum of shell architectures and sizes. While our results suggested a certain level of variability inherent for all methods, we conclude that a single measure using sand/water is likely to be sufficient for the majority of studies. However, care must be taken as precision may decline with increasing shell size and structural complexity. CT provided less variation between repeat measures but volume estimates were consistently lower compared to sand/water and will need methodological improvements before it can be used as an alternative. CT indicated volume may be also underestimated using sand/water due to the presence of air spaces visible in filled shells scanned by CT. Lastly, we encourage authors to clearly describe how volume estimates were obtained.

  17. Assessment of metabolic phenotypic variability in children’s urine using 1H NMR spectroscopy

    NASA Astrophysics Data System (ADS)

    Maitre, Léa; Lau, Chung-Ho E.; Vizcaino, Esther; Robinson, Oliver; Casas, Maribel; Siskos, Alexandros P.; Want, Elizabeth J.; Athersuch, Toby; Slama, Remy; Vrijheid, Martine; Keun, Hector C.; Coen, Muireann

    2017-04-01

    The application of metabolic phenotyping in clinical and epidemiological studies is limited by a poor understanding of inter-individual, intra-individual and temporal variability in metabolic phenotypes. Using 1H NMR spectroscopy we characterised short-term variability in urinary metabolites measured from 20 children aged 8-9 years old. Daily spot morning, night-time and pooled (50:50 morning and night-time) urine samples across six days (18 samples per child) were analysed, and 44 metabolites quantified. Intraclass correlation coefficients (ICC) and mixed effect models were applied to assess the reproducibility and biological variance of metabolic phenotypes. Excellent analytical reproducibility and precision was demonstrated for the 1H NMR spectroscopic platform (median CV 7.2%). Pooled samples captured the best inter-individual variability with an ICC of 0.40 (median). Trimethylamine, N-acetyl neuraminic acid, 3-hydroxyisobutyrate, 3-hydroxybutyrate/3-aminoisobutyrate, tyrosine, valine and 3-hydroxyisovalerate exhibited the highest stability with over 50% of variance specific to the child. The pooled sample was shown to capture the most inter-individual variance in the metabolic phenotype, which is of importance for molecular epidemiology study design. A substantial proportion of the variation in the urinary metabolome of children is specific to the individual, underlining the potential of such data to inform clinical and exposome studies conducted early in life.

  18. [Validation of the IBS-SSS].

    PubMed

    Betz, C; Mannsdörfer, K; Bischoff, S C

    2013-10-01

    Irritable bowel syndrome (IBS) is a functional gastrointestinal disorder characterised by abdominal pain, associated with stool abnormalities and changes in stool consistency. Diagnosis of IBS is based on characteristic symptoms and exclusion of other gastrointestinal diseases. A number of questionnaires exist to assist diagnosis and assessment of severity of the disease. One of these is the irritable bowel syndrome - severity scoring system (IBS-SSS). The IBS-SSS was validated 1997 in its English version. In the present study, the IBS-SSS has been validated in German language. To do this, a cohort of 60 patients with IBS according to the Rome III criteria, was compared with a control group of healthy individuals (n = 38). We studied sensitivity and reproducibility of the score, as well as the sensitivity to detect changes of symptom severity. The results of the German validation largely reflect the results of the English validation. The German version of the IBS-SSS is also a valid, meaningful and reproducible questionnaire with a high sensitivity to assess changes in symptom severity, especially in IBS patients with moderate symptoms. It is unclear if the IBS-SSS is also a valid questionnaire in IBS patients with severe symptoms because this group of patients was not studied. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Repeatability and Reproducibility of Virtual Subjective Refraction.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-10-01

    To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.

  20. Inter-rater agreement in evaluation of disability: systematic review of reproducibility studies

    PubMed Central

    Barth, Jürgen; de Boer, Wout E L; Busse, Jason W; Hoving, Jan L; Kedzia, Sarah; Couban, Rachel; Fischer, Katrin; von Allmen, David Y; Spanjer, Jerry

    2017-01-01

    Objectives To explore agreement among healthcare professionals assessing eligibility for work disability benefits. Design Systematic review and narrative synthesis of reproducibility studies. Data sources Medline, Embase, and PsycINFO searched up to 16 March 2016, without language restrictions, and review of bibliographies of included studies. Eligibility criteria Observational studies investigating reproducibility among healthcare professionals performing disability evaluations using a global rating of working capacity and reporting inter-rater reliability by a statistical measure or descriptively. Studies could be conducted in insurance settings, where decisions on ability to work include normative judgments based on legal considerations, or in research settings, where decisions on ability to work disregard normative considerations.Teams of paired reviewers identified eligible studies, appraised their methodological quality and generalisability, and abstracted results with pretested forms. As heterogeneity of research designs and findings impeded a quantitative analysis, a descriptive synthesis stratified by setting (insurance or research) was performed. Results From 4562 references, 101 full text articles were reviewed. Of these, 16 studies conducted in an insurance setting and seven in a research setting, performed in 12 countries, met the inclusion criteria. Studies in the insurance setting were conducted with medical experts assessing claimants who were actual disability claimants or played by actors, hypothetical cases, or short written scenarios. Conditions were mental (n=6, 38%), musculoskeletal (n=4, 25%), or mixed (n=6, 38%). Applicability of findings from studies conducted in an insurance setting to real life evaluations ranged from generalisable (n=7, 44%) and probably generalisable (n=3, 19%) to probably not generalisable (n=6, 37%). Median inter-rater reliability among experts was 0.45 (range intraclass correlation coefficient 0.86 to κ−0.10). Inter-rater reliability was poor in six studies (37%) and excellent in only two (13%). This contrasts with studies conducted in the research setting, where the median inter-rater reliability was 0.76 (range 0.91-0.53), and 71% (5/7) studies achieved excellent inter-rater reliability. Reliability between assessing professionals was higher when the evaluation was guided by a standardised instrument (23 studies, P=0.006). No such association was detected for subjective or chronic health conditions or the studies’ generalisability to real world evaluation of disability (P=0.46, 0.45, and 0.65, respectively). Conclusions Despite their common use and far reaching consequences for workers claiming disabling injury or illness, research on the reliability of medical evaluations of disability for work is limited and indicates high variation in judgments among assessing professionals. Standardising the evaluation process could improve reliability. Development and testing of instruments and structured approaches to improve reliability in evaluation of disability are urgently needed. PMID:28122727

  1. Response assessment challenges in clinical trials of gliomas.

    PubMed

    Wen, Patrick Y; Norden, Andrew D; Drappatz, Jan; Quant, Eudocia

    2010-01-01

    Accurate, reproducible criteria for determining tumor response and progression after therapy are critical for optimal patient care and effective evaluation of novel therapeutic agents. Currently, the most widely used criteria for determining treatment response in gliomas is based on two-dimensional tumor measurements using neuroimaging studies (Macdonald criteria). In recent years, the limitation of these criteria, which only address the contrast-enhancing component of the tumor, have become increasingly apparent. This review discusses challenges that have emerged in assessing response in patients with gliomas and approaches being introduced to address them.

  2. Reproducibility of DCE-MRI time-intensity curve-shape analysis in patients with knee arthritis: A comparison with qualitative and pharmacokinetic analyses.

    PubMed

    van der Leij, Christiaan; Lavini, Cristina; van de Sande, Marleen G H; de Hair, Marjolein J H; Wijffels, Christophe; Maas, Mario

    2015-12-01

    To compare the between-session reproducibility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) combined with time-intensity curve (TIC)-shape analysis in arthritis patients, within one scanner and between two different scanners, and to compare this method with qualitative analysis and pharmacokinetic modeling (PKM). Fifteen knee joint arthritis patients were included and scanned twice on a closed-bore 1.5T scanner (n = 9, group 1), or on a closed-bore 1.5T and on an open-bore 1.0T scanner (n = 6, group 2). DCE-MRI data were postprocessed using in-house developed software ("Dynamo"). Disease activity was assessed. Disease activity was comparable between the two visits. In group 1 qualitative analysis showed the highest reproducibility with intraclass correlation coefficients (ICCs) between 0.78 and 0.98 and root mean square-coefficients of variation (RMS-CoV) of 8.0%-14.9%. TIC-shape analysis showed a slightly lower reproducibility with similar ICCs (0.78-0.97) but higher RMS-CoV (18.3%-42.9%). The PKM analysis showed the lowest reproducibility with ICCs between 0.39 and 0.64 (RMS-CoV 21.5%-51.9%). In group 2 TIC-shape analysis of the two most important TIC-shape types showed the highest reproducibility with ICCs of 0.78 and 0.71 (RMS-CoV 29.8% and 59.4%) and outperformed the reproducibility of the most important qualitative parameter (ICC 0.31, RMS-CoV 45.1%) and the within-scanner reproducibility of PKM analysis. TIC-shape analysis is a robust postprocessing method within one scanner, almost as reproducible as the qualitative analysis. Between scanners, the reproducibility of the most important TIC-shapes outperform that of the most important qualitative parameter and the within-scanner reproducibility of PKM analysis. © 2015 Wiley Periodicals, Inc.

  3. A Preclinical Consortium Approach for Assessing the Efficacy of Combined Anti-CD3 Plus IL-1 Blockade in Reversing New-Onset Autoimmune Diabetes in NOD Mice

    PubMed Central

    Gill, Ronald G.; Pagni, Philippe P.; Kupfer, Tinalyn; Wasserfall, Clive H.; Deng, Songyan; Posgai, Amanda; Manenkova, Yulia; Bel Hani, Amira; Straub, Laura; Bernstein, Philip; Atkinson, Mark A.; Herold, Kevan C.; von Herrath, Matthias; Staeva, Teodora; Ehlers, Mario R.; Nepom, Gerald T.

    2016-01-01

    There is an ongoing need to develop strategic combinations of therapeutic agents to prevent type 1 diabetes (T1D) or to preserve islet β-cell mass in new-onset disease. Although clinical trials using candidate therapeutics are commonly based on preclinical studies, concern is growing regarding the reproducibility as well as the potential clinical translation of reported results using animal models of human disorders. In response, the National Institutes of Health Immune Tolerance Network and JDRF established a multicenter consortium of academic institutions designed to assess the efficacy and intergroup reproducibility of clinically applicable immunotherapies for reversing new-onset disease in the NOD mouse model of T1D. Predicated on prior studies, this consortium conducted coordinated, prospective studies, using joint standard operating procedures, fixed criteria for study entry, and common reagents, to optimize combined anti-CD3 treatment plus interleukin-1 (IL-1) blockade to reverse new-onset disease in NOD mice. We did not find that IL-1 blockade with anti–IL-1β monoclonal antibody or IL-1trap provided additional benefit for reversing new-onset disease compared with anti-CD3 treatment alone. These results demonstrate the value of larger, multicenter preclinical studies for vetting and prioritizing therapeutics for future clinical use. PMID:26718498

  4. Quantifying patterns of research interest evolution

    NASA Astrophysics Data System (ADS)

    Jia, Tao; Wang, Dashun; Szymanski, Boleslaw

    Changing and shifting research interest is an integral part of a scientific career. Despite extensive investigations of various factors that influence a scientist's choice of research topics, quantitative assessments of mechanisms that give rise to macroscopic patterns characterizing research interest evolution of individual scientists remain limited. Here we perform a large-scale analysis of extensive publication records, finding that research interest change follows a reproducible pattern characterized by an exponential distribution. We identify three fundamental features responsible for the observed exponential distribution, which arise from a subtle interplay between exploitation and exploration in research interest evolution. We develop a random walk based model, which adequately reproduces our empirical observations. Our study presents one of the first quantitative analyses of macroscopic patterns governing research interest change, documenting a high degree of regularity underlying scientific research and individual careers.

  5. iPSC-derived neurons as a higher-throughput readout for autism: Promises and pitfalls

    PubMed Central

    Prilutsky, Daria; Palmer, Nathan P.; Smedemark-Margulies, Niklas; Schlaeger, Thorsten M.; Margulies, David M.; Kohane, Isaac S.

    2014-01-01

    The elucidation of disease etiologies and establishment of robust, scalable, high-throughput screening assays for autism spectrum disorders (ASDs) have been impeded by both inaccessibility of disease-relevant neuronal tissue and the genetic heterogeneity of the disorder. Neuronal cells derived from induced pluripotent stem cells (iPSCs) from autism patients may circumvent these obstacles and serve as relevant cell models. To date, derived cells are characterized and screened by assessing their neuronal phenotypes. These characterizations are often etiology-specific or lack reproducibility and stability. In this manuscript, we present an overview of efforts to study iPSC-derived neurons as a model for autism, and we explore the plausibility of gene expression profiling as a reproducible and stable disease marker. PMID:24374161

  6. A theoretical and experimental benchmark study of core-excited states in nitrogen

    NASA Astrophysics Data System (ADS)

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan; Nandi, Saikat; Coriani, Sonia; Gühr, Markus; Koch, Henrik

    2018-02-01

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. The computational results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.

  7. Imputation of adverse drug reactions: Causality assessment in hospitals

    PubMed Central

    Mastroianni, Patricia de Carvalho

    2017-01-01

    Background & objectives Different algorithms have been developed to standardize the causality assessment of adverse drug reactions (ADR). Although most share common characteristics, the results of the causality assessment are variable depending on the algorithm used. Therefore, using 10 different algorithms, the study aimed to compare inter-rater and multi-rater agreement for ADR causality assessment and identify the most consistent to hospitals. Methods Using ten causality algorithms, four judges independently assessed the first 44 cases of ADRs reported during the first year of implementation of a risk management service in a medium complexity hospital in the state of Sao Paulo (Brazil). Owing to variations in the terminology used for causality, the equivalent imputation terms were grouped into four categories: definite, probable, possible and unlikely. Inter-rater and multi-rater agreement analysis was performed by calculating the Cohen´s and Light´s kappa coefficients, respectively. Results None of the algorithms showed 100% reproducibility in the causal imputation. Fair inter-rater and multi-rater agreement was found. Emanuele (1984) and WHO-UMC (2010) algorithms showed a fair rate of agreement between the judges (k = 0.36). Interpretation & conclusions Although the ADR causality assessment algorithms were poorly reproducible, our data suggest that WHO-UMC algorithm is the most consistent for imputation in hospitals, since it allows evaluating the quality of the report. However, to improve the ability of assessing the causality using algorithms, it is necessary to include criteria for the evaluation of drug-related problems, which may be related to confounding variables that underestimate the causal association. PMID:28166274

  8. Assessments A to Z: A Collection of 50 Questionnaires, Instruments, and Inventories.

    ERIC Educational Resources Information Center

    Burn, Bonnie; Payment, Maggi

    This collection of reproducible instruments is designed to help trainers evaluate the performance of their students and to evaluate their success of the training itself. Part 1 discusses assessments and their use. Part 2 contains a topic and assessment matrix and includes 50 assessments that measure various job-related attitudes, knowledge, and…

  9. Comparing two methods to record maximal voluntary contractions and different electrode positions in recordings of forearm extensor muscle activity: Refining risk assessments for work-related wrist disorders.

    PubMed

    Dahlqvist, Camilla; Nordander, Catarina; Granqvist, Lothy; Forsman, Mikael; Hansson, Gert-Åke

    2018-01-01

    Wrist disorders are common in force demanding industrial repetitive work. Visual assessment of force demands have a low reliability, instead surface electromyography (EMG) may be used as part of a risk assessment for work-related wrist disorders. For normalization of EMG recordings, a power grip (hand grip) is often used as maximal voluntary contraction (MVC) of the forearm extensor muscles. However, the test-retest reproducibility is poor and EMG amplitudes exceeding 100% have occasionally been recorded during work. An alternative MVC is resisted wrist extension, which may be more reliable. To compare hand grip and resisted wrist extension MVCs, in terms of amplitude and reproducibility, and to examine the effect of electrode positioning. Twelve subjects participated. EMG from right forearm extensors, from four electrode pairs, was recorded during MVCs, on three separate occasions. The group mean EMG amplitudes for resisted wrist extension were 1.2-1.7 times greater than those for hand grip. Resisted wrist extension showed better reproducibility than hand grip. The results indicate that the use of resisted wrist extension is a more accurate measurement of maximal effort of wrist extensor contractions than using hand grip and should increase the precision in EMG recordings from forearm extensor muscles, which in turn will increase the quality of risk assessments that are based on these.

  10. Extreme Rainfall Events Over Southern Africa: Assessment of a Climate Model to Reproduce Daily Extremes

    NASA Astrophysics Data System (ADS)

    Williams, C.; Kniveton, D.; Layberry, R.

    2007-12-01

    It is increasingly accepted that any possible climate change will not only have an influence on mean climate but may also significantly alter climatic variability. This issue is of particular importance for environmentally vulnerable regions such as southern Africa. The subcontinent is considered especially vulnerable extreme events, due to a number of factors including extensive poverty, disease and political instability. Rainfall variability and the identification of rainfall extremes is a function of scale, so high spatial and temporal resolution data are preferred to identify extreme events and accurately predict future variability. The majority of previous climate model verification studies have compared model output with observational data at monthly timescales. In this research, the assessment of a state-of-the-art climate model to simulate climate at daily timescales is carried out using satellite derived rainfall data from the Microwave Infra-Red Algorithm (MIRA). This dataset covers the period from 1993-2002 and the whole of southern Africa at a spatial resolution of 0.1 degree longitude/latitude. Once the model's ability to reproduce extremes has been assessed, idealised regions of SST anomalies are used to force the model, with the overall aim of investigating the ways in which SST anomalies influence rainfall extremes over southern Africa. In this paper, results from sensitivity testing of the UK Meteorological Office Hadley Centre's climate model's domain size are firstly presented. Then simulations of current climate from the model, operating in both regional and global mode, are compared to the MIRA dataset at daily timescales. Thirdly, the ability of the model to reproduce daily rainfall extremes will be assessed, again by a comparison with extremes from the MIRA dataset. Finally, the results from the idealised SST experiments are briefly presented, suggesting associations between rainfall extremes and both local and remote SST anomalies.

  11. Examining the Reproducibility of 6 Published Studies in Public Health Services and Systems Research.

    PubMed

    Harris, Jenine K; B Wondmeneh, Sarah; Zhao, Yiqiang; Leider, Jonathon P

    2018-02-23

    Research replication, or repeating a study de novo, is the scientific standard for building evidence and identifying spurious results. While replication is ideal, it is often expensive and time consuming. Reproducibility, or reanalysis of data to verify published findings, is one proposed minimum alternative standard. While a lack of research reproducibility has been identified as a serious and prevalent problem in biomedical research and a few other fields, little work has been done to examine the reproducibility of public health research. We examined reproducibility in 6 studies from the public health services and systems research subfield of public health research. Following the methods described in each of the 6 papers, we computed the descriptive and inferential statistics for each study. We compared our results with the original study results and examined the percentage differences in descriptive statistics and differences in effect size, significance, and precision of inferential statistics. All project work was completed in 2017. We found consistency between original and reproduced results for each paper in at least 1 of the 4 areas examined. However, we also found some inconsistency. We identified incorrect transcription of results and omitting detail about data management and analyses as the primary contributors to the inconsistencies. Increasing reproducibility, or reanalysis of data to verify published results, can improve the quality of science. Researchers, journals, employers, and funders can all play a role in improving the reproducibility of science through several strategies including publishing data and statistical code, using guidelines to write clear and complete methods sections, conducting reproducibility reviews, and incentivizing reproducible science.

  12. Data sharing and reanalysis of randomized controlled trials in leading biomedical journals with a full data sharing policy: survey of studies published in The BMJ and PLOS Medicine

    PubMed Central

    Naudet, Florian; Sakarovitch, Charlotte; Janiaud, Perrine; Cristea, Ioana; Fanelli, Daniele; Moher, David

    2018-01-01

    Abstract Objectives To explore the effectiveness of data sharing by randomized controlled trials (RCTs) in journals with a full data sharing policy and to describe potential difficulties encountered in the process of performing reanalyses of the primary outcomes. Design Survey of published RCTs. Setting PubMed/Medline. Eligibility criteria RCTs that had been submitted and published by The BMJ and PLOS Medicine subsequent to the adoption of data sharing policies by these journals. Main outcome measure The primary outcome was data availability, defined as the eventual receipt of complete data with clear labelling. Primary outcomes were reanalyzed to assess to what extent studies were reproduced. Difficulties encountered were described. Results 37 RCTs (21 from The BMJ and 16 from PLOS Medicine) published between 2013 and 2016 met the eligibility criteria. 17/37 (46%, 95% confidence interval 30% to 62%) satisfied the definition of data availability and 14 of the 17 (82%, 59% to 94%) were fully reproduced on all their primary outcomes. Of the remaining RCTs, errors were identified in two but reached similar conclusions and one paper did not provide enough information in the Methods section to reproduce the analyses. Difficulties identified included problems in contacting corresponding authors and lack of resources on their behalf in preparing the datasets. In addition, there was a range of different data sharing practices across study groups. Conclusions Data availability was not optimal in two journals with a strong policy for data sharing. When investigators shared data, most reanalyses largely reproduced the original results. Data sharing practices need to become more widespread and streamlined to allow meaningful reanalyses and reuse of data. Trial registration Open Science Framework osf.io/c4zke. PMID:29440066

  13. Analysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008–2014 REACH Data

    PubMed Central

    Luechtefeld, Thomas; Maertens, Alexandra; Russo, Daniel P.; Rovida, Costanza; Zhu, Hao; Hartung, Thomas

    2017-01-01

    Summary Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test’s reproducibility based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation after a prior severe-irritant result according to UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation, we built a dataset of 5,629 substances (1,931 “irritant” and 3,698 “non-irritant”). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data (“May cause respiratory irritation”), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area. PMID:26863293

  14. Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

    PubMed Central

    Lee, Nak Bum

    2009-01-01

    Background/Aims Despite the clinical importance and widespread use of pulse wave velocity (PWV), there are no standards for pulse sensors or for system requirements to ensure accurate pulse wave measurement. We assessed the reproducibility of PWV values using a newly developed PWV measurement system. Methods The system used in this study was the PP-1000, which simultaneously provides regional PWV values from arteries at four different sites (carotid, femoral, radial, and dorsalis pedis). Seventeen healthy male subjects without any cardiovascular disease participated in this study. Two observers performed two consecutive measurements in the same subject in random order. To evaluate the reproducibility of the system, two sets of analyses (within-observer and between-observer) were performed. Results The means±SD of PWV for the aorta, arm, and leg were 7.0±1.48, 8.43±1.14, and 8.09±0.98 m/s as measured by observer A and 6.76±1.00, 7.97±0.80, and 7.97±0.72 m/s by observer B, respectively. Between-observer differences for the aorta, arm, and leg were 0.14±0.62, 0.18±0.84, and 0.07±0.86 m/s, respectively, and the correlation coefficients were high, especially for aortic PWV (r=0.93). All the measurements showed significant correlation coefficients, ranging from 0.94 to 0.99. Conclusions The PWV measurement system used in this study provides accurate analysis results with high reproducibility. It is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. PMID:19270477

  15. Inter-reader reproducibility of dynamic contrast-enhanced magnetic resonance imaging in patients with non-small cell lung cancer treated with bevacizumab and erlotinib.

    PubMed

    van den Boogaart, Vivian E M; de Lussanet, Quido G; Houben, Ruud M A; de Ruysscher, Dirk; Groen, Harry J M; Marcus, J Tim; Smit, Egbert F; Dingemans, Anne-Marie C; Backes, Walter H

    2016-03-01

    Objectives When evaluating anti-tumor treatment response by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) it is necessary to assure its validity and reproducibility. This has not been well addressed in lung tumors. Therefore we have evaluated the inter-reader reproducibility of response classification by DCE-MRI in patients with non-small cell lung cancer (NSCLC) treated with bevacizumab and erlotinib enrolled in a multicenter trial. Twenty-one patients were scanned before and 3 weeks after start of treatment with DCE-MRI in a multicenter trial. The scans were evaluated by two independent readers. The primary lung tumor was used for response assessment. Responses were assessed in terms of relative changes in tumor mean trans endothelial transfer rate (K(trans)) and its heterogeneity in terms of the spatial standard deviation. Reproducibility was expressed by the inter-reader variability, intra-class correlation coefficient (ICC) and dichotomous response classification. The inter-reader variability and ICC for the relative K(trans) were 5.8% and 0.930, respectively. For tumor heterogeneity the inter-reader variability and ICC were 0.017 and 0.656, respectively. For the two readers the response classification for relative K(trans) was concordant in 20 of 21 patients (k=0.90, p<0.0001) and for tumor heterogeneity in 19 of 21 patients (k=0.80, p<0.0001). Strong agreement was seen with regard to the inter-reader variability and reproducibility of response classification by the two readers of lung cancer DCE-MRI scans. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Peripapillary nerve fiber layer thickness measurement reproducibility using optical coherence tomography.

    PubMed

    Villain, Max A; Greenfield, David S

    2003-01-01

    To assess reproducibility of quadrantic and clock hour sectors of retinal nerve fiber layer thickness in normal eyes using optical coherence tomography. Normal eyes of healthy volunteers meeting eligibility criteria were imaged by two inexperienced operators. Six 360 degrees circular scans with a diameter of 3.4 mm centered on the optic disc were obtained during each scanning session, and a baseline image was formed using 3 high-quality images defined by the software. Images were obtained on three different days within a 4-week period. Variance and coefficient of variation (CV) were calculated for quadrantic and retinal nerve fiber layer clock hour sectors obtained from the baseline image. Five normal eyes were scanned. Intraoperator reproducibility was high. The mean (+/- SD) CV for total retinal nerve fiber layer thickness was 5.3 +/- 3.82% and 4.33 +/- 3.7% for operators 1 and 2, respectively. Interoperator reproducibility was good with statistically similar variance for all quadrantic and clock hour retinal nerve fiber layer parameters (P = .42 to .99). The nasal retinal nerve fiber layer was the most variable sector for both operators (mean CV: 10.42% and 7.83% for operators 1 and 2, respectively). Differences in mean total, nasal, temporal, and superior retinal nerve fiber layer thickness were not statistically significant between operators for all eyes; however, for inferior retinal nerve fiber layer thickness, there was a significant (P = .0007) difference between operators in one eye. Peripapillary retinal nerve fiber layer thickness assessments using optical coherence tomography have good intraoperator and interoperator reproducibility. Inexperienced operators can generate useful measurement data with acceptable levels of variance.

  17. Reproducibility of UAV-based earth surface topography based on structure-from-motion algorithms.

    NASA Astrophysics Data System (ADS)

    Clapuyt, François; Vanacker, Veerle; Van Oost, Kristof

    2014-05-01

    A representation of the earth surface at very high spatial resolution is crucial to accurately map small geomorphic landforms with high precision. Very high resolution digital surface models (DSM) can then be used to quantify changes in earth surface topography over time, based on differencing of DSMs taken at various moments in time. However, it is compulsory to have both high accuracy for each topographic representation and consistency between measurements over time, as DSM differencing automatically leads to error propagation. This study investigates the reproducibility of reconstructions of earth surface topography based on structure-from-motion (SFM) algorithms. To this end, we equipped an eight-propeller drone with a standard reflex camera. This equipment can easily be deployed in the field, as it is a lightweight, low-cost system in comparison with classic aerial photo surveys and terrestrial or airborne LiDAR scanning. Four sets of aerial photographs were created for one test field. The sets of airphotos differ in focal length, and viewing angles, i.e. nadir view and ground-level view. In addition, the importance of the accuracy of ground control points for the construction of a georeferenced point cloud was assessed using two different GPS devices with horizontal accuracy at resp. the sub-meter and sub-decimeter level. Airphoto datasets were processed with SFM algorithm and the resulting point clouds were georeferenced. Then, the surface representations were compared with each other to assess the reproducibility of the earth surface topography. Finally, consistency between independent datasets is discussed.

  18. [Reliability of nursing outcomes classification label "Knowledge: cardiac disease management (1830)" in outpatients with heart failure].

    PubMed

    Cañón-Montañez, Wilson; Oróstegui-Arenas, Myriam

    2015-01-01

    To determine the reliability (internal consistency, inter-rater reproducibility and level of agreement) of nursing outcome: "Knowledge: cardiac disease management (1830)" of the version published in Spanish, in outpatients with heart failure. A reliability study was conducted on 116 outpatients with heart failure. Six indicators of nursing outcome were operationalized. All participants were assessed simultaneously by two evaluators. Three evaluation periods were defined: initial (at baseline), final (a month later), and follow-up (two months later). Internal consistency by Cronbach alpha coefficient, inter-rater reproducibility with intraclass correlation coefficient of reproducibility or agreement and level agreement using the 95% limits of Bland and Altman. Cronbach's alpha was 0.83 (95% CI: 0.77 - 0.89) in the final evaluation, and follow-up values of 0.85 (95% CI: 0.82-0.89) and 0.83 (95% CI: 0.78 - 0.88) were found for the first and second evaluator, respectively. The intraclass correlation coefficient showed values greater 0.9 in the three evaluation periods in both the random and mixed model. The Bland-Altman 95% limits of agreement were close to zero in the three evaluations performed. The questionnaire operationalized to assess the nursing outcome: "Knowledge: cardiac disease management (1830)" in its Spanish version, is a reliable method to measure skills and knowledge in outpatients with heart failure in the Colombian context. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  19. New insight in spiral drawing analysis methods - Application to action tremor quantification.

    PubMed

    Legrand, André Pierre; Rivals, Isabelle; Richard, Aliénor; Apartis, Emmanuelle; Roze, Emmanuel; Vidailhet, Marie; Meunier, Sabine; Hainque, Elodie

    2017-10-01

    Spiral drawing is one of the standard tests used to assess tremor severity for the clinical evaluation of medical treatments. Tremor severity is estimated through visual rating of the drawings by movement disorders experts. Different approaches based on the mathematical signal analysis of the recorded spiral drawings were proposed to replace this rater dependent estimate. The objective of the present study is to propose new numerical methods and to evaluate them in terms of agreement with visual rating and reproducibility. Series of spiral drawings of patients with essential tremor were visually rated by a board of experts. In addition to the usual velocity analysis, three new numerical methods were tested and compared, namely static and dynamic unraveling, and empirical mode decomposition. The reproducibility of both visual and numerical ratings was estimated, and their agreement was evaluated. The statistical analysis demonstrated excellent agreement between visual and numerical ratings, and more reproducible results with numerical methods than with visual ratings. The velocity method and the new numerical methods are in good agreement. Among the latter, static and dynamic unravelling both display a smaller dispersion and are easier for automatic analysis. The reliable scores obtained through the proposed numerical methods allow considering that their implementation on a digitized tablet, be it connected with a computer or independent, provides an efficient automatic tool for tremor severity assessment. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  20. In Vitro Continuous Fermentation Model (PolyFermS) of the Swine Proximal Colon for Simultaneous Testing on the Same Gut Microbiota

    PubMed Central

    Tanner, Sabine A.; Zihler Berner, Annina; Rigozzi, Eugenia; Grattepanche, Franck; Chassard, Christophe; Lacroix, Christophe

    2014-01-01

    In vitro gut modeling provides a useful platform for a fast and reproducible assessment of treatment-related changes. Currently, pig intestinal fermentation models are mainly batch models with important inherent limitations. In this study we developed a novel in vitro continuous fermentation model, mimicking the porcine proximal colon, which we validated during 54 days of fermentation. This model, based on our recent PolyFermS design, allows comparing different treatment effects on the same microbiota. It is composed of a first-stage inoculum reactor seeded with immobilized fecal swine microbiota and used to constantly inoculate (10% v/v) five second-stage reactors, with all reactors fed with fresh nutritive chyme medium and set to mimic the swine proximal colon. Reactor effluents were analyzed for metabolite concentrations and bacterial composition by HPLC and quantitative PCR, and microbial diversity was assessed by 454 pyrosequencing. The novel PolyFermS featured stable microbial composition, diversity and metabolite production, consistent with bacterial activity reported for swine proximal colon in vivo. The constant inoculation provided by the inoculum reactor generated reproducible microbial ecosystems in all second-stage reactors, allowing the simultaneous investigation and direct comparison of different treatments on the same porcine gut microbiota. Our data demonstrate the unique features of this novel PolyFermS design for the swine proximal colon. The model provides a tool for efficient, reproducible and cost-effective screening of environmental factors, such as dietary additives, on pig colonic fermentation. PMID:24709947

  1. In vitro continuous fermentation model (PolyFermS) of the swine proximal colon for simultaneous testing on the same gut microbiota.

    PubMed

    Tanner, Sabine A; Zihler Berner, Annina; Rigozzi, Eugenia; Grattepanche, Franck; Chassard, Christophe; Lacroix, Christophe

    2014-01-01

    In vitro gut modeling provides a useful platform for a fast and reproducible assessment of treatment-related changes. Currently, pig intestinal fermentation models are mainly batch models with important inherent limitations. In this study we developed a novel in vitro continuous fermentation model, mimicking the porcine proximal colon, which we validated during 54 days of fermentation. This model, based on our recent PolyFermS design, allows comparing different treatment effects on the same microbiota. It is composed of a first-stage inoculum reactor seeded with immobilized fecal swine microbiota and used to constantly inoculate (10% v/v) five second-stage reactors, with all reactors fed with fresh nutritive chyme medium and set to mimic the swine proximal colon. Reactor effluents were analyzed for metabolite concentrations and bacterial composition by HPLC and quantitative PCR, and microbial diversity was assessed by 454 pyrosequencing. The novel PolyFermS featured stable microbial composition, diversity and metabolite production, consistent with bacterial activity reported for swine proximal colon in vivo. The constant inoculation provided by the inoculum reactor generated reproducible microbial ecosystems in all second-stage reactors, allowing the simultaneous investigation and direct comparison of different treatments on the same porcine gut microbiota. Our data demonstrate the unique features of this novel PolyFermS design for the swine proximal colon. The model provides a tool for efficient, reproducible and cost-effective screening of environmental factors, such as dietary additives, on pig colonic fermentation.

  2. In Vivo Imaging of Cortical Inflammation and Subpial Pathology in Multiple Sclerosis by Combined PET and MRI

    DTIC Science & Technology

    2016-09-01

    second-generation TSPO PET tracer with ~80 times more specific binding than 11C-PK1119520, and good reproducibility. In experimental studies inflammation...function). One patient was excluded because resulted as low-affinity binder, one subject withdrew from the study , one was later excluded because it...targeted enrollment has not been completed yet, the main aims of the study have been assessed in 12 RR MS cases , which have also been compared to 15

  3. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population

    PubMed Central

    González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida

    2018-01-01

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance. PMID:29690618

  4. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population.

    PubMed

    Bernal-Orozco, María Fernanda; Badillo-Camacho, Nayeli; Macedo-Ojeda, Gabriela; González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida; Vizmanos, Barbara

    2018-04-23

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April⁻August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  5. Reproducibility of ECG-gated ultrasound diameter assessment of small abdominal aortic aneurysms.

    PubMed

    Bredahl, K; Eldrup, N; Meyer, C; Eiberg, J E; Sillesen, H

    2013-03-01

    No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation. Prospective comparative study. Consecutive patients (N = 27) with an AAA, attending their 6-month control as part of a medical treatment trial, were scanned twice by two ultrasound operators. Then, all ultrasound recordings were transferred to a core facility and analysed by a third person. The AAA diameter was determined in four different ways: from the leading edge of adventitia on the anterior wall to either the leading edge of the adventitia (method A) or leading edge of the intima (method B) on the posterior wall, with both measurements performed in systole and diastole. Inter-operator reproducibility was ± 3 mm for all methods applied. There was no difference in outcome between methods A and B; likewise, end-diastolic measurement did not improve reproducibility in preference to peak-systolic measurement. The use of a standardised ultrasound protocol including ECG-gating and subsequent off-line reading with minute calliper placement reduces variability. This may be of use in developing protocols to better detect even small AAA growth rates during clinical trials. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Feasibility of using auto Mod-MPI system, a novel technique for automated measurement of fetal modified myocardial performance index.

    PubMed

    Lee, M-Y; Won, H-S; Jeon, E-J; Yoon, H C; Choi, J Y; Hong, S J; Kim, M-J

    2014-06-01

    To evaluate the reproducibility of measurement of the fetal left modified myocardial performance index (Mod-MPI) determined using a novel automated system. This was a prospective study of 116 ultrasound examinations from 110 normal singleton pregnancies at 12 + 1 to 37 + 1 weeks' gestation. Two experienced operators each measured the left Mod-MPI twice manually and twice automatically using the Auto Mod-MPI system. Intra- and interoperator reproducibility were assessed using intraclass correlation coefficients (ICCs) and the manual and automated measurements obtained by the more experienced operator were compared using Bland-Altman plots and ICCs. Both operators successfully measured the left Mod-MPI in all cases using the Auto Mod-MPI system. For both operators, intraoperator reproducibility was higher when performing automated measurements (ICC = 0.967 and 0.962 for Operators 1 and 2, respectively) than when performing manual measurements (ICC = 0.857 and 0.856 for Operators 1 and 2, respectively). Interoperator agreement was also better for automated than for manual measurements (ICC = 0.930 vs 0.723, respectively). There was good agreement between the automated and manual values measured by the more experienced operator. The Auto Mod-MPI system is a reliable technique for measuring fetal left Mod-MPI and demonstrates excellent reproducibility. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  7. Quantitative blood flow measurements in gliomas using arterial spin-labeling at 3T: intermodality agreement and inter- and intraobserver reproducibility study.

    PubMed

    Hirai, T; Kitajima, M; Nakamura, H; Okuda, T; Sasao, A; Shigematsu, Y; Utsunomiya, D; Oda, S; Uetani, H; Morioka, M; Yamashita, Y

    2011-12-01

    QUASAR is a particular application of the ASL method and facilitates the user-independent quantification of brain perfusion. The purpose of this study was to assess the intermodality agreement of TBF measurements obtained with ASL and DSC MR imaging and the inter- and intraobserver reproducibility of glioma TBF measurements acquired by ASL at 3T. Two observers independently measured TBF in 24 patients with histologically proved glioma. ASL MR imaging with QUASAR and DSC MR imaging were performed on 3T scanners. The observers placed 5 regions of interest in the solid tumor on rCBF maps derived from ASL and DSC MR images and 1 region of interest in the contralateral brain and recorded the measured values. Maximum and average sTBF values were calculated. Intermodality and intra- and interobsever agreement were determined by using 95% Bland-Altman limits of agreement and ICCs. The intermodality agreement for maximum sTBF was good to excellent on DSC and ASL images; ICCs ranged from 0.718 to 0.884. The 95% limits of agreement ranged from 59.2% to 65.4% of the mean. ICCs for intra- and interobserver agreement for maximum sTBF ranged from 0.843 to 0.850 and from 0.626 to 0.665, respectively. The reproducibility of maximum sTBF measurements obtained by methods was similar. In the evaluation of sTBF in gliomas, ASL with QUASAR at 3T yielded measurements and reproducibility similar to those of DSC perfusion MR imaging.

  8. Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography.

    PubMed

    Olszewski, R; Frison, L; Wisniewski, M; Denis, J M; Vynckier, S; Cosnard, G; Zech, F; Reychler, H

    2013-01-01

    The purpose of this study is to compare the reproducibility of three-dimensional cephalometric landmarks on three-dimensional computed tomography (3D-CT) surface rendering using clinical protocols based on low-dose (35-mAs) spiral CT and cone-beam CT (I-CAT). The absorbed dose levels for radiosensitive organs in the maxillofacial region during exposure in both 3D-CT protocols were also assessed. The study population consisted of ten human dry skulls examined with low-dose CT and cone-beam CT. Two independent observers identified 24 cephalometric anatomic landmarks at 13 sites on the 3D-CT surface renderings using both protocols, with each observer repeating the identification 1 month later. A total of 1,920 imaging measurements were performed. Thermoluminescent dosimeters were placed at six sites around the thyroid gland, the submandibular glands, and the eyes in an Alderson phantom to measure the absorbed dose levels. When comparing low-dose CT and cone-beam CT protocols, the cone-beam CT protocol proved to be significantly more reproducible for four of the 13 anatomical sites. There was no significant difference between the protocols for the other nine anatomical sites. Both low-dose and cone-beam CT protocols were equivalent in dose absorption to the eyes and submandibular glands. However, thyroid glands were more irradiated with low-dose CT. Cone-beam CT was more reproducible and procured less irradiation to the thyroid gland than low-dose CT. Cone-beam CT should be preferred over low-dose CT for developing three-dimensional bony cephalometric analyses.

  9. Reproducibility of combinatorial peptide ligand libraries for proteome capture evaluated by selected reaction monitoring.

    PubMed

    Di Girolamo, Francesco; Righetti, Pier Giorgio; Soste, Martin; Feng, Yuehan; Picotti, Paola

    2013-08-26

    Systems biology studies require the capability to quantify with high precision proteins spanning a broad range of abundances across multiple samples. However, the broad range of protein expression in cells often precludes the detection of low-abundance proteins. Different sample processing techniques can be applied to increase proteome coverage. Among these, combinatorial (hexa)peptide ligand libraries (CPLLs) bound to solid matrices have been used to specifically capture and detect low-abundance proteins in complex samples. To assess whether CPLL capture can be applied in systems biology studies involving the precise quantitation of proteins across a multitude of samples, we evaluated its performance across the whole range of protein abundances in Saccharomyces cerevisiae. We used selected reaction monitoring assays for a set of target proteins covering a broad abundance range to quantitatively evaluate the precision of the approach and its capability to detect low-abundance proteins. Replicated CPLL-isolates showed an average variability of ~10% in the amount of the isolated proteins. The high reproducibility of the technique was not dependent on the abundance of the protein or the amount of beads used for the capture. However, the protein-to-bead ratio affected the enrichment of specific proteins. We did not observe a normalization effect of CPLL beads on protein abundances. However, CPLLs enriched for and depleted specific sets of proteins and thus changed the abundances of proteins from a whole proteome extract. This allowed the identification of ~400 proteins otherwise undetected in an untreated sample, under the experimental conditions used. CPLL capture is thus a useful tool to increase protein identifications in proteomic experiments, but it should be coupled to the analysis of untreated samples, to maximize proteome coverage. Our data also confirms that CPLL capture is reproducible and can be confidently used in quantitative proteomic experiments. Combinatorial hexapeptide ligand libraries (CPLLs) bound to solid matrices have been proposed to specifically capture and detect low-abundance proteins in complex samples. To assess whether the CPLL capture can be confidently applied in systems biology studies involving the precise quantitation of proteins across a broad range of abundances and a multitude of samples, we evaluated its reproducibility and performance features. Using selected reaction monitoring assays for proteins covering the whole range of abundances we show that the technique is reproducible and compatible with quantitative proteomic studies. However, the protein-to-bead ratio affects the enrichment of specific proteins and CPLLs depleted specific sets of proteins from a whole proteome extract. Our results suggest that CPLL-based analyses should be coupled to the analysis of untreated samples, to maximize proteome coverage. Overall, our data confirms the applicability of CPLLs in systems biology research and guides the correct use of this technique. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Introduction of an automated user-independent quantitative volumetric magnetic resonance imaging breast density measurement system using the Dixon sequence: comparison with mammographic breast density assessment.

    PubMed

    Wengert, Georg Johannes; Helbich, Thomas H; Vogl, Wolf-Dieter; Baltzer, Pascal; Langs, Georg; Weber, Michael; Bogner, Wolfgang; Gruber, Stephan; Trattnig, Siegfried; Pinker, Katja

    2015-02-01

    The purposes of this study were to introduce and assess an automated user-independent quantitative volumetric (AUQV) breast density (BD) measurement system on the basis of magnetic resonance imaging (MRI) using the Dixon technique as well as to compare it with qualitative and quantitative mammographic (MG) BD measurements. Forty-three women with normal mammogram results (Breast Imaging Reporting and Data System 1) were included in this institutional review board-approved prospective study. All participants were subjected to BD assessment with MRI using the following sequence with the Dixon technique (echo time/echo time, 6 milliseconds/2.45 milliseconds/2.67 milliseconds; 1-mm isotropic; 3 minutes 38 seconds). To test the reproducibility, a second MRI after patient repositioning was performed. The AUQV magnetic resonance (MR) BD measurement system automatically calculated percentage (%) BD. The qualitative BD assessment was performed using the American College of Radiology Breast Imaging Reporting and Data System BD categories. Quantitative BD was estimated semiautomatically using the thresholding technique Cumulus4. Appropriate statistical tests were used to assess the agreement between the AUQV MR measurements and to compare them with qualitative and quantitative MG BD estimations. The AUQV MR BD measurements were successfully performed in all 43 women. There was a nearly perfect agreement of AUQV MR BD measurements between the 2 MR examinations for % BD (P < 0.001; intraclass correlation coefficient, 0.998) with no significant differences (P = 0.384). The AUQV MR BD measurements were significantly lower than quantitative and qualitative MG BD assessment (P < 0.001). The AUQV MR BD measurement system allows a fully automated, user-independent, robust, reproducible, as well as radiation- and compression-free volumetric quantitative BD assessment through different levels of BD. The AUQV MR BD measurements were significantly lower than the currently used qualitative and quantitative MG-based approaches, implying that the current assessment might overestimate breast density with MG.

  11. Normative data and predictors of leg muscle function and postural control in children.

    PubMed

    Hazell, Tom J; Sharma, Atul K; Vanstone, Catherine A; Gagnon, Isabelle; Pham, Thu Trang; Finch, Sarah L; Weiler, Hope A; Rodd, Celia J

    2014-11-01

    At the present there are limited tools available to measure muscle function in young children. Ground reaction force plates measure lower-body function and postural control in older children and adults. The purpose of this study was threefold: 1) develop normative data for evaluating global muscle development; 2) determine the reproducibility of ground reaction force plates for assessing muscle function in preschool-age children; and 3) identify predictors of skeletal muscle function. Children's (n = 81, 1.8 to 6.0 yr; M = 52%) muscle function and postural control was measured for jump (JMP), sit-to-stand (STS), and both undistracted and distracted body sway tests using a ground reaction force plate (Kistler 9200A). Whole body composition used dual-energy x-ray absorptiometry (Hologic 4500A Discovery Series). Plasma 25-hydroxyvitamin D [25(OH)D] and parathyroid hormone concentrations were measured by chemiluminescence (Liaison, Diasorin, Mississauga, ON, Canada) as well as ionized calcium (ABL80 FLEX, Radiometer Medical A/S). Demographics, and anthropometry were collected. ANOVA and linear regression were used to identify predictors. Reproducibility was assessed by intersubject coefficient of variation. Age was a consistent predictor in all models; body size or fat and lean mass were important predictors in 3 of the models - STS peak force, STS peak power, and JMP peak power. STS was the most reproducible maneuver (average coefficient of variation =15.7%). Distracted body sway testing was not appropriate in these youngsters. The novel data presented in this study demonstrate a clear age (developmental) effect without any effect of sex on muscle function and postural control in young children. Lean muscle mass was important in some models (STS peak force and JMP peak power). The STS test was the best of the 4 maneuvers.

  12. Validation of Ten Noninvasive Diagnostic Models for Prediction of Liver Fibrosis in Patients with Chronic Hepatitis B

    PubMed Central

    Cheng, Jieyao; Hou, Jinlin; Ding, Huiguo; Chen, Guofeng; Xie, Qing; Wang, Yuming; Zeng, Minde; Ou, Xiaojuan; Ma, Hong; Jia, Jidong

    2015-01-01

    Background and Aims Noninvasive models have been developed for fibrosis assessment in patients with chronic hepatitis B. However, the sensitivity, specificity and diagnostic accuracy in evaluating liver fibrosis of these methods have not been validated and compared in the same group of patients. The aim of this study was to verify the diagnostic performance and reproducibility of ten reported noninvasive models in a large cohort of Asian CHB patients. Methods The diagnostic performance of ten noninvasive models (HALF index, FibroScan, S index, Zeng model, Youyi model, Hui model, APAG, APRI, FIB-4 and FibroTest) was assessed against the liver histology by ROC curve analysis in CHB patients. The reproducibility of the ten models were evaluated by recalculating the diagnostic values at the given cut-off values defined by the original studies. Results Six models (HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest) had AUROCs higher than 0.70 in predicting any fibrosis stage and 2 of them had best diagnostic performance with AUROCs to predict F≥2, F≥3 and F4 being 0.83, 0.89 and 0.89 for HALF index, 0.82, 0.87 and 0.87 for FibroScan, respectively. Four models (HALF index, FibroScan, Zeng model and Youyi model) showed good diagnostic values at given cut-offs. Conclusions HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest show a good diagnostic performance and all of them, except S index and FibroTest, have good reproducibility for evaluating liver fibrosis in CHB patients. Registration Number ChiCTR-DCS-07000039. PMID:26709706

  13. Reproducibility of Echocardiograph-Derived Multilevel Left Ventricular Apical Twist Mechanics.

    PubMed

    Stewart, Glenn M; Yamada, Akira; Kavanagh, Justin J; Haseler, Luke J; Chan, Jonathan; Sabapathy, Surendran

    2016-02-01

    Left ventricular (LV) twist mechanics are routinely assessed via echocardiography in clinical and research trials investigating the function of obliquely oriented myocardial fibers. However, echocardiograph-derived measures of LV twist may be compromised by nonstandardized acquisition of the apical image. This study examined the reproducibility of echocardiograph-derived parameters of apical twist mechanics at multiple levels of the apical myocardium. Two sets of 2D LV parasternal short-axis images were obtained in 30 healthy subjects (24 men; 19-57 year) via echocardiography. Images were acquired immediately distal to the papillary muscles (apical image 1), immediately above the point of LV cavity obliteration at end systole (apical image 3), and midway between apical image 1 and apical image 3 (apical image 2). Repeat scans were performed within 1 hour, and twist mechanics (rotation and rotation rate) were calculated via frame-by-frame tracking of natural acoustic echocardiographic markers (speckle tracking). The magnitude of apical rotation increased progressively toward the apex (apical image 1: 4.2 ± 2.1°, apical image 2: 7.2 ± 3.9°, apical image 3: 11.8 ± 4.6°). apical images 1, 2, and 3 each had moderate to good correlations between repeat scans (ICC: 0.531-0.856). When apical images 1, 2, and 3 were averaged, rotation was 7.7 ± 2.7° and between-scan correlation was excellent (ICC: 0.910). Similar results were observed for systolic and diastolic rotation rates. Averaging multiple standardized apical images, tending progressively toward the apex, generated the most reproducible rotation indices and may be optimal for the assessment of LV twist mechanics across therapeutic, interventional, and research studies; however, care should be taken given the influence of acquisition level on the magnitude of apical rotation. © 2015, Wiley Periodicals, Inc.

  14. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    PubMed

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  15. An International Ki67 Reproducibility Study in Adrenal Cortical Carcinoma.

    PubMed

    Papathomas, Thomas G; Pucci, Eugenio; Giordano, Thomas J; Lu, Hao; Duregon, Eleonora; Volante, Marco; Papotti, Mauro; Lloyd, Ricardo V; Tischler, Arthur S; van Nederveen, Francien H; Nose, Vania; Erickson, Lori; Mete, Ozgur; Asa, Sylvia L; Turchini, John; Gill, Anthony J; Matias-Guiu, Xavier; Skordilis, Kassiani; Stephenson, Timothy J; Tissier, Frédérique; Feelders, Richard A; Smid, Marcel; Nigg, Alex; Korpershoek, Esther; van der Spek, Peter J; Dinjens, Winand N M; Stubbs, Andrew P; de Krijger, Ronald R

    2016-04-01

    Despite the established role of Ki67 labeling index in prognostic stratification of adrenocortical carcinomas and its recent integration into treatment flow charts, the reproducibility of the assessment method has not been determined. The aim of this study was to investigate interobserver variability among endocrine pathologists using a web-based virtual microscopy approach. Ki67-stained slides of 76 adrenocortical carcinomas were analyzed independently by 14 observers, each according to their method of preference including eyeballing, formal manual counting, and digital image analysis. The interobserver variation was statistically significant (P<0.001) in the absence of any correlation between the various methods. Subsequently, 61 static images were distributed among 15 observers who were instructed to follow a category-based scoring approach. Low levels of interobserver (F=6.99; Fcrit=1.70; P<0.001) as well as intraobserver concordance (n=11; Cohen κ ranging from -0.057 to 0.361) were detected. To improve harmonization of Ki67 analysis, we tested the utility of an open-source Galaxy virtual machine application, namely Automated Selection of Hotspots, in 61 virtual slides. The software-provided Ki67 values were validated by digital image analysis in identical images, displaying a strong correlation of 0.96 (P<0.0001) and dividing the cases into 3 classes (cutoffs of 0%-15%-30% and/or 0%-10%-20%) with significantly different overall survivals (P<0.05). We conclude that current practices in Ki67 scoring assessment vary greatly, and interobserver variation sets particular limitations to its clinical utility, especially around clinically relevant cutoff values. Novel digital microscopy-enabled methods could provide critical aid in reducing variation, increasing reproducibility, and improving reliability in the clinical setting.

  16. Nanoshell assisted laser soldering of vascular tissue.

    PubMed

    Schöni, Daniel S; Bogni, Serge; Bregy, Amadé; Wirth, Amina; Raabe, Andreas; Vajtai, Istvan; Pieles, Uwe; Reinert, Michael; Frenz, Martin

    2011-12-01

    Laser tissue soldering (LTS) is a promising technique for tissue fusion but is limited by the lack of reproducibility particularly when the amount of indocyanine green (ICG) applied as energy absorber cannot be controlled during the soldering procedure. Nanotechnology enables the control over the quantitative binding of the ICG. The aim of this study was to establish a highly reproducible and strong tissue fusion using ICG packed nanoshells. By including the chromophore in the soldering scaffold, dilution of the energy absorber during the soldering procedure is prevented. The feasibility of this novel nanoshell soldering technique was studied by assessing the local heating of the area and tensile strength of the resulting fused tissue. Nanoshells with a diameter of 250-270 nm were loaded with ICG and included in a porous polycaprolactone (PCL) scaffold doped with albumin solder. The nanoshell scaffold was used in a flexible, semi-dry formulation suitable for surgical use. Heat development, tensile strength as well as tissue damage were assessed. Rabbit aortic arteries were successfully soldered using an ICG packed nanoshell scaffold. Tensile strengths of these nanoshell soldered anastomoses were found to be 734 ± 327 mN (median = 640 mN). Thermal damage was restricted to the adventitia at the irradiated area. In addition, absorber dilution was prevented during the soldering procedure resulting in significantly lower variance in maximum temperature (P = 0.03) compared to the classical liquid ICG soldering technique. Using nanoshells, controlled amounts of chromophore could successfully be bound into the polymer scaffold. Diode laser soldering of vascular tissue using ICG-nanoshell scaffolds leads to strong and reproducible tissue fusion. With optimally chosen settings of irradiation time, nanoshells coating and scaffold properties, our improved LTS procedure demonstrates the potential for a clinically applicable anastomosis technique. Copyright © 2011 Wiley Periodicals, Inc.

  17. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Y; Yang, Y; Rangwala, N

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometricmore » reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent geometric fidelity, accurate and highly reproducible ADC measurements was proposed for longitudinal tumor response assessment using an MRI-guided RT system. Yu Gao acknowledges research support from ViewRay.« less

  18. Reproducibility and Transparency of Omics Research - Impacts on Human Health Risk Assessment

    EPA Science Inventory

    Omics technologies are becoming more widely used in toxicology, necessitating their consideration in human health hazard and risk assessment programs. Today, risk assessors in the United States Environmental Protection Agency’s Integrated Risk Information System (IRIS) Toxicologi...

  19. Reliability of vascular geometry factors derived from clinical MRA

    NASA Astrophysics Data System (ADS)

    Bijari, Payam B.; Antiga, Luca; Steinman, David A.

    2009-02-01

    Recent work from our group has demonstrated that the amount of disturbed flow at the carotid bifurcation, believed to be a local risk factor for carotid atherosclerosis, can be predicted from luminal geometric factors. The next step along the way to a large-scale retrospective or prospective imaging study of such local risk factors for atherosclerosis is to investigate whether these geometric features are reproducible and accurate from routine 3D contrast-enhanced magnetic resonance angiography (CEMRA) using a fast and practical method of extraction. Motivated by this fact, we examined the reproducibility of multiple geometric features that are believed important in atherosclerosis risk assessment. We reconstructed three-dimensional carotid bifurcations from 15 clinical study participants who had previously undergone baseline and repeat CEMRA acquisitions. Certain geometric factors were extracted and compared between the baseline and the repeat scan. As the spatial resolution of the CEMRA data was noticeably coarse and anisotropic, we also investigated whether this might affect the measurement of the same geometric risk factors by simulating the CEMRA acquisition for 15 normal carotid bifurcations previously acquired at high resolution. Our results show that the extracted geometric factors are reproducible and faithful, with intra-subject uncertainties well below inter-subject variabilities. More importantly, these geometric risk factors can be extracted consistently and quickly for potential use as disturbed flow predictors.

  20. A scoring metric for multivariate data for reproducibility analysis using chemometric methods

    PubMed Central

    Sheen, David A.; de Carvalho Rocha, Werickson Fortunato; Lippa, Katrice A.; Bearden, Daniel W.

    2017-01-01

    Process quality control and reproducibility in emerging measurement fields such as metabolomics is normally assured by interlaboratory comparison testing. As a part of this testing process, spectral features from a spectroscopic method such as nuclear magnetic resonance (NMR) spectroscopy are attributed to particular analytes within a mixture, and it is the metabolite concentrations that are returned for comparison between laboratories. However, data quality may also be assessed directly by using binned spectral data before the time-consuming identification and quantification. Use of the binned spectra has some advantages, including preserving information about trace constituents and enabling identification of process difficulties. In this paper, we demonstrate the use of binned NMR spectra to conduct a detailed interlaboratory comparison and composition analysis. Spectra of synthetic and biologically-obtained metabolite mixtures, taken from a previous interlaboratory study, are compared with cluster analysis using a variety of distance and entropy metrics. The individual measurements are then evaluated based on where they fall within their clusters, and a laboratory-level scoring metric is developed, which provides an assessment of each laboratory’s individual performance. PMID:28694553

  1. Comparison of qualitative and quantitative analysis of T2-weighted MRI scans in chronic-progressive multiple sclerosis

    NASA Astrophysics Data System (ADS)

    Adams, Hans-Peter; Wagner, Simone; Koziol, James A.

    1998-06-01

    Magnetic resonance imaging (MRI) is routinely used for the diagnosis of multiple sclerosis (MS), and for objective assessment of the extent of disease as a marker of treatment efficacy in MS clinical trials. The purpose of this study is to compare the evaluation of T2-weighted MRI scans in MS patients using a semi-automated quantitative technique with an independent assessment by a neurologist. Baseline, 6- month, and 12-month T2-weighted MRI scans from 41 chronic progressive MS patients were examined. The lesion volume ranged from 0.50 to 51.56 cm2 (mean: 8.08 cm2). Reproducibility of the quantitative technique was assessed by the re-evaluation of a random subset of 20 scans, the coefficient of variation of the replicate determinations was 8.2%. The reproducibility of the neurologist evaluations was assessed by the re-evaluation of a random subset of 10 patients. The rank correlation between the results of the two methods was 0.097, which did not significantly differ from zero. Disease-related activity in T2-weighted MRI scans is a multi-dimensional construct, and is not adequately summarized solely by determination of lesion volume. In this setting, image analysis software should not only support storage and retrieval as sets of pixels, but should also support links to an anatomical dictionary.

  2. Optimizing multi-dimensional high throughput screening using zebrafish

    PubMed Central

    Truong, Lisa; Bugel, Sean M.; Chlebowski, Anna; Usenko, Crystal Y.; Simonich, Michael T.; Massey Simonich, Staci L.; Tanguay, Robert L.

    2016-01-01

    The use of zebrafish for high throughput screening (HTS) for chemical bioactivity assessments is becoming routine in the fields of drug discovery and toxicology. Here we report current recommendations from our experiences in zebrafish HTS. We compared the effects of different high throughput chemical delivery methods on nominal water concentration, chemical sorption to multi-well polystyrene plates, transcription responses, and resulting whole animal responses. We demonstrate that digital dispensing consistently yields higher data quality and reproducibility compared to standard plastic tip-based liquid handling. Additionally, we illustrate the challenges in using this sensitive model for chemical assessment when test chemicals have trace impurities. Adaptation of these better practices for zebrafish HTS should increase reproducibility across laboratories. PMID:27453428

  3. Liver diffusion-weighted MR imaging: reproducibility comparison of ADC measurements obtained with multiple breath-hold, free-breathing, respiratory-triggered, and navigator-triggered techniques.

    PubMed

    Chen, Xin; Qin, Lei; Pan, Dan; Huang, Yanqi; Yan, Lifen; Wang, Guangyi; Liu, Yubao; Liang, Changhong; Liu, Zaiyi

    2014-04-01

    To prospectively compare the reproducibility of normal liver apparent diffusion coefficient (ADC) measurements by using different respiratory motion compensation techniques with multiple breath-hold (MBH), free-breathing (FB), respiratory-triggered (RT), and navigator-triggered (NT) diffusion-weighted (DW) imaging and to compare the ADCs at different liver anatomic locations. The study protocol was approved by the institutional review board, and written informed consent was obtained from each participant. Thirty-nine volunteers underwent liver DW imaging twice. Imaging was performed with a 1.5-T MR imager with MBH, FB, RT, and NT techniques (b = 0, 100, and 500 sec/mm(2)). Three representative sections--superior, central, and inferior--were selected on left and right liver lobes, respectively. On each selected section, three regions of interest were drawn, and ADCs were measured. Analysis of variance was used to assess ADCs among the four techniques and various anatomic locations. Reproducibility of ADCs was assessed with the Bland-Altman method. ADCs obtained with MBH (range: right lobe, [1.641-1.662] × 10(-3)mm(2)/sec; left lobe, [2.034-2.054] ×10(-3)mm(2)/sec) were higher than those obtained with FB (right, [1.349-1.391] ×10(-3)mm(2)/sec; left, [1.630-1.700] ×10(-3)mm(2)/sec), RT (right, [1.439-1.455] ×10(-3)mm(2)/sec; left, [1.720-1.755] ×10(-3)mm(2)/sec), or NT (right, [1.387-1.400] ×10(-3)mm(2)/sec; left, [1.661-1.736] ×10(-3)mm(2)/sec) techniques (P < .001); however, no significant difference was observed between ADCs obtained with FB, RT, and NT techniques (P = .130 to P >.99). ADCs showed a trend to decrease moving from left to right. Reproducibility in the left liver lobe was inferior to that in the right, and the central middle segment in the right lobe had the most reproducible ADC. Statistical differences in ADCs were observed in the left-right direction in the right lobe (P < .001), but they were not observed in the superior-inferior direction (P = .144-.450). However, in the left liver lobe, statistical differences existed in both directions (P = .001 to P = .016 in the left-right direction, P < .001 in the superior-inferior direction). Both anatomic location and DW imaging technique influence liver ADC measurements and their reproducibility. FB DW imaging is recommended for liver DW imaging because of its good reproducibility and shorter acquisition time compared with that of MBH, RT, and NT techniques. RSNA, 2014

  4. Frontal parenchymal atrophy measures in multiple sclerosis.

    PubMed

    Locatelli, Laura; Zivadinov, Robert; Grop, Attilio; Zorzon, Marino

    2004-10-01

    The aim of this study was to establish whether, in a cross-sectional study, the normalized measures of whole and regional brain atrophy correlate better with tests assessing the cognitive function than the absolute brain atrophy measures. The neuropsychological performances and disability have been assessed in 39 patients with relapsing-remitting multiple sclerosis (MS). T1- and T2-lesion load (LL) of total brain and frontal lobes (FLs) were measured using a reproducible semiautomated technique. The whole brain volume and the regional brain parenchymal volume (RBPV) of FLs were obtained using a computerized interactive program, which incorporates semiautomated and automated segmentation processes. Normalized measures of brain atrophy, i.e., brain parenchymal fraction (BPF) and regional brain parenchymal fraction (RBPF) of FLs, were calculated. The scan-rescan, inter- and intrarater coefficient of variation (COV) and intraclass correlation coefficient (ICC) have been estimated. The RBPF of FLs showed an acceptable level of reproducibility which ranged from 1.7% for intrarater variability to 3.2% for scan-rescan variability. The mean ICC was 0.88 (CI 0.82-0.93). The RBPF of FLs demonstrated stronger magnitudes of correlation with neuropsychological functioning, disability and quantitative MRI lesion measures than RBPV. These differences were statistically significant: P<0.001 for Stroop Color Word Interference test, P<0.001 for Paced Auditory Serial Addition Test, P=0.04 for Standard Raven Progressive Matrices, P=0.049 for Expanded Disability Status Scale, P=0.01 for T2-LL of FLs and P<0.001 for T1-LL of FLs. BPF demonstrated significant correlations with tests assessing cognitive functions, whereas BPAV did not. The correlation analysis results were supported by the results of multiple regression analysis which showed that only the normalized brain atrophy measures were associated with tests exploring the cognitive functions. These data suggest that RBPF is a reproducible and sensitive method for measuring frontal parenchymal atrophy. The normalized measures of whole and regional brain parenchymal atrophy should be preferred to absolute measures in future studies that correlate neuropsychological performances and brain atrophy measures in patients with MS.

  5. Standardization of Sonographic Lung-to-Head Ratio Measurements in Isolated Congenital Diaphragmatic Hernia: Impact on the Reproducibility and Efficacy to Predict Outcomes.

    PubMed

    Britto, Ingrid Schwach Werneck; Sananes, Nicolas; Olutoye, Oluyinka O; Cass, Darrell L; Sangi-Haghpeykar, Haleh; Lee, Timothy C; Cassady, Christopher I; Mehollin-Ray, Amy; Welty, Stephen; Fernandes, Caraciolo; Belfort, Michael A; Lee, Wesley; Ruano, Rodrigo

    2015-10-01

    The purpose of this study was to evaluate the impact of standardization of the lung-to-head ratio measurements in isolated congenital diaphragmatic hernia on prediction of neonatal outcomes and reproducibility. We conducted a retrospective cohort study of 77 cases of isolated congenital diaphragmatic hernia managed in a single center between 2004 and 2012. We compared lung-to-head ratio measurements that were performed prospectively in our institution without standardization to standardized measurements performed according to a defined protocol. The standardized lung-to-head ratio measurements were statistically more accurate than the nonstandardized measurements for predicting neonatal mortality (area under the receiver operating characteristic curve, 0.85 versus 0.732; P = .003). After standardization, there were no statistical differences in accuracy between measurements regardless of whether we considered observed-to-expected values (P > .05). Standardization of the lung-to-head ratio did not improve prediction of the need for extracorporeal membrane oxygenation (P> .05). Both intraoperator and interoperator reproducibility were good for the standardized lung-to-head ratio (intraclass correlation coefficient, 0.98 [95% confidence interval, 0.97-0.99]; bias, 0.02 [limits of agreement, -0.11 to +0.15], respectively). Standardization of lung-to-head ratio measurements improves prediction of neonatal outcomes. Further studies are needed to confirm these results and to assess the utility of standardization of other prognostic parameters.

  6. Comparison of Collection Methods for Fecal Samples in Microbiome Studies

    PubMed Central

    Vogtmann, Emily; Chen, Jun; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi

    2017-01-01

    Prospective cohort studies are needed to assess the relationship between the fecal microbiome and human health and disease. To evaluate fecal collection methods, we determined technical reproducibility, stability at ambient temperature, and accuracy of 5 fecal collection methods (no additive, 95% ethanol, RNAlater Stabilization Solution, fecal occult blood test cards, and fecal immunochemical test tubes). Fifty-two healthy volunteers provided fecal samples at the Mayo Clinic in Rochester, Minnesota, in 2014. One set from each sample collection method was frozen immediately, and a second set was incubated at room temperature for 96 hours and then frozen. Intraclass correlation coefficients (ICCs) were calculated for the relative abundance of 3 phyla, 2 alpha diversity metrics, and 4 beta diversity metrics. Technical reproducibility was high, with ICCs for duplicate fecal samples between 0.64 and 1.00. Stability for most methods was generally high, although the ICCs were below 0.60 for 95% ethanol in metrics that were more sensitive to relative abundance. When compared with fecal samples that were frozen immediately, the ICCs were below 0.60 for the metrics that were sensitive to relative abundance; however, the remaining 2 alpha diversity and 3 beta diversity metrics were all relatively accurate, with ICCs above 0.60. In conclusion, all fecal sample collection methods appear relatively reproducible, stable, and accurate. Future studies could use these collection methods for microbiome analyses. PMID:27986704

  7. Assessment of eating disorders with the diabetes eating problems survey - revised (DEPS-R) in a representative sample of insulin-treated diabetic patients: a validation study in Italy.

    PubMed

    Pinna, Federica; Diana, Enrica; Sanna, Lucia; Deiana, Valeria; Manchia, Mirko; Nicotra, Eraldo; Fiorillo, Andrea; Albert, Umberto; Nivoli, Alessandra; Volpe, Umberto; Atti, Anna Rita; Ferrari, Silvia; Medda, Federica; Atzeni, Maria Gloria; Manca, Daniela; Mascia, Elisa; Farci, Fernando; Ghiani, Mariangela; Cau, Rossella; Tuveri, Marta; Cossu, Efisio; Loy, Elena; Mereu, Alessandra; Mariotti, Stefano; Carpiniello, Bernardo

    2017-07-19

    The purpose of the study was to evaluate in a sample of insulin-treated diabetic patients, with type 1 or type 2 diabetes, the psychometric characteristics of the Italian version of the DEPS-R scale, a diabetes-specific self-report questionnaire used to analyze disordered eating behaviors. The study was performed on 211 consecutive insulin-treated diabetic patients attending two specialist centers. Lifetime prevalence of eating disorders (EDs) according to DSM-IV and DSM-5 criteria were assessed by means of the Module H of the Structured Clinical Interview for DSM IV Axis I Disorder and the Module H modified, according to DSM-5 criteria. The following questionnaires were administered: DEPS-R and the Eating Disorder Inventory - 3 (EDI-3). Test/retest reproducibility was assessed on a subgroup of 70 patients. The factorial structure, internal consistency, test-retest reliability and concurrent validity of DEPS-R were assessed. Overall, 21.8% of the sample met criteria for at least one DSM-5 diagnosis of ED. A "clinical risk" of ED was observed in 13.3% of the sample. Females displayed higher scores at DEPS-R, a higher percentage of at least one diagnosis of ED and a higher clinical risk for ED. A high level of reproducibility and homogeneity of the scale were revealed. A significant correlation was detected between DEPS-R and the 3 ED risk scales of EDI-3. The data confirmed the overall reliability and validity of the scale. In view of the significance and implications of EDs in diabetic patients, it should be conducted a more extensive investigation of the phenomenon by means of evaluation instruments of demonstrated validity and reliability.

  8. Assessing regeneration potential

    Treesearch

    Ivan L. Sander

    1989-01-01

    When a regeneration harvest cut is planned for even-aged stands or it is time to make another cut in uneven-aged stands, the first thing to do is assess the regeneration potential. Regeneration potential is the likelihood of being successful in reproducing desired species. You need an assessment to be reasonably sure that regeneration and management objectives can be...

  9. First French Pilot Quality Assessment of the EndoPredict Test for Early Luminal Breast Carcinoma.

    PubMed

    Lehmann-Che, Jacqueline; Miquel, Catherine; Wong, Jennifer; Callens, Celine; Rouleau, Etienne; Quillien, Veronique; Lozano, Nicolas; Cayre, Anne; Lacroix, Ludovic; Bieche, Ivan; Bertheau, Philippe; Teixeira, Luis; Llorca, Frederique Penault; Lamy, Pierre Jean; DE Cremoux, Patricia

    2018-05-01

    Genomic signatures are needed for the determination of prognosis in patients with early stage, estrogen receptor (ER)-positive, human epidermal growth factor receptor 2 (HER2)-negative breast cancers. EndoPredict test is a RNA-based multigene assay that assesses the risk of 10-year relapse in this context. Quality assessment is a mandatory requirement for a laboratory to address the analytical quality of these molecular analyses. The aim of the study was to demonstrate the robustness of this prognostic test, its usefulness for the patient's treatment strategy, at the national level. This study presents a pilot quality assessment (QA) of the EndoPredict test using composite design, including the follow-up of internal control values (qREF) of the 12 genes of the assay for 151 independent tests and one formalin-fixed paraffin embedded (FFPE) breast cancer sample. The evaluation of the test was performed by comparing the results of six independent medical laboratories. All measures were highly reproducible and quantification of the qREF showed a standard deviation of less than 0.50 and a coefficient of variation always of <2%. All laboratories found concordant results for the breast cancer samples. The mean EndoPredict (EP) score for the breast cancer sample was 4.97±0.24. The mean of EPclin score was 3.07±0.05. This first French independent reported QA assessed the robustness and reproducibility of the EndoPredict test. Such a simple composite design could represent an adapted QA for an expensive diagnostic test. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. Relative Validity and Reproducibility of a Food Frequency Questionnaire for Assessing Dietary Intakes in a Multi-Ethnic Asian Population Using 24-h Dietary Recalls and Biomarkers

    PubMed Central

    Whitton, Clare; Ho, Jolene Chien Yee; Tay, Zoey; Rebello, Salome A.; Lu, Yonghai; Ong, Choon Nam; van Dam, Rob M.

    2017-01-01

    The assessment of diets in multi-ethnic cosmopolitan settings is challenging. A semi-quantitative 163-item food frequency questionnaire (FFQ) was developed for the adult Singapore population, and this study aimed to assess its reproducibility and relative validity against 24-h dietary recalls (24 h DR) and biomarkers. The FFQ was administered twice within a six-month interval in 161 adults (59 Chinese, 46 Malay, and 56 Indian). Fasting plasma, overnight urine, and 24 h DR were collected after one month and five months. Intra-class correlation coefficients between the two FFQ were above 0.70 for most foods and nutrients. The median correlation coefficient between energy-adjusted deattenuated FFQ and 24 h DR nutrient intakes was 0.40 for FFQ1 and 0.39 for FFQ2, highest for calcium and iron, and lowest for energy and carbohydrates. Significant associations were observed between urinary isoflavones and soy protein intake (r = 0.46), serum carotenoids and fruit and vegetable intake (r = 0.34), plasma eicosapentaenoic acid and docosahexaenoic acid (EPA + DHA) and fish/seafood intake (r = 0.36), and plasma odd chain saturated fatty acids (SFA) and dairy fat intake (r = 0.25). Associations between plasma EPA + DHA and fish/seafood intake were consistent across ethnic groups (r = 0.28–0.49), while differences were observed for other associations. FFQ assessment of dietary intakes in modern cosmopolitan populations remains feasible for the purpose of ranking individuals’ dietary exposures in epidemiological studies. PMID:28946670

  11. Validation of self assessment patient knowledge questionnaire for heart failure patients.

    PubMed

    Lainscak, Mitja; Keber, Irena

    2005-12-01

    Several studies showed insufficient knowledge and poor compliance to non-pharmacological management in heart failure patients. Only a limited number of validated tools are available to assess their knowledge. The aim of the study was to test our 10-item Patient knowledge questionnaire. The Patient knowledge questionnaire was administered to 42 heart failure patients from Heart failure clinic and to 40 heart failure patients receiving usual care. Construct validity (Pearson correlation coefficient), internal consistency (Cronbach alpha), reproducibility (Wilcoxon signed rank test), and reliability (chi-square test and Student's t-test for independent samples) were assessed. Overall score of the Patient knowledge questionnaire had the strongest correlation to the question about regular weighing (r=0.69) and the weakest to the question about presence of heart disease (r=0.33). There was a strong correlation between question about fluid retention and questions assessing regular weighing, (r=0.86), weight of one litre of water (r=0.86), and salt restriction (r=0.57). The Cronbach alpha was 0.74 and could be improved by exclusion of questions about clear explanation (Chronbach alpha 0.75), importance of fruit, soup, and vegetables (Chronbach alpha 0.75), and self adjustment of diuretic (Chronbach alpha 0.81). During reproducibility testing 91% to 98% of questions were answered equally. Patients from Heart failure clinic scored significantly better than patients receiving usual care (7.9 (1.3) vs. 5.7 (2.2), p<0.001). Patient knowledge questionnaire is a valid and reliable tool to measure knowledge of heart failure patients.

  12. Quantification of mitral valve regurgitation in dogs with degenerative mitral valve disease by use of the proximal isovelocity surface area method.

    PubMed

    Gouni, Vassiliki; Serres, François J; Pouchelon, Jean-Louis; Tissier, Renaud; Lefebvre, Hervé P; Nicolle, Audrey P; Sampedrano, Carolina Carlos; Chetboul, Valérie

    2007-08-01

    To determine the within-day and between-day variability of regurgitant fraction (RF) assessed by use of the proximal isovelocity surface area (PISA) method in awake dogs with degenerative mitral valve disease (MVD), measure RF in dogs with MVD, and assess the correlation between RF and several clinical and Doppler echocardiographic variables. Prospective study. 6 MVD-affected dogs with no clinical signs and 67 dogs with MVD of differing severity (International Small Animal Cardiac Health Council [ISACHC] classification). The 6 dogs were used to determine the repeatability and reproducibility of the PISA method, and RF was then assessed in 67 dogs of various ISACHC classes. Mitral valve regurgitation was also assessed from the maximum area of regurgitant jet signal-to-left atrium area (ARJ/LAA) ratio determined via color Doppler echocardiographic mapping. Within- and between-day coefficients of variation of RF were 8% and 11%, respectively. Regurgitation fraction was significantly correlated with ISACHC classification and heart murmur grade and was higher in ISACHC class III dogs (mean +/- SD, 72.8 +/- 9.5%) than class II (57.9 +/- 20.1%) or I (40.7 +/- 19.2%) dogs. Regurgitation fraction and left atriumto-aorta ratio, fractional shortening, systolic pulmonary arterial pressure, and ARJ/LAA ratio were significantly correlated. Results suggested that RF is a repeatable and reproducible variable for noninvasive quantitative evaluation of mitral valve regurgitation in awake dogs. Regurgitation fraction also correlated well with disease severity. It appears that this Doppler echocardiographic index may be useful in longitudinal studies of MVD in dogs.

  13. Relative Validity and Reproducibility of a Food Frequency Questionnaire for Assessing Dietary Intakes in a Multi-Ethnic Asian Population Using 24-h Dietary Recalls and Biomarkers.

    PubMed

    Whitton, Clare; Ho, Jolene Chien Yee; Tay, Zoey; Rebello, Salome A; Lu, Yonghai; Ong, Choon Nam; van Dam, Rob M

    2017-09-25

    The assessment of diets in multi-ethnic cosmopolitan settings is challenging. A semi-quantitative 163-item food frequency questionnaire (FFQ) was developed for the adult Singapore population, and this study aimed to assess its reproducibility and relative validity against 24-h dietary recalls (24 h DR) and biomarkers. The FFQ was administered twice within a six-month interval in 161 adults (59 Chinese, 46 Malay, and 56 Indian). Fasting plasma, overnight urine, and 24 h DR were collected after one month and five months. Intra-class correlation coefficients between the two FFQ were above 0.70 for most foods and nutrients. The median correlation coefficient between energy-adjusted deattenuated FFQ and 24 h DR nutrient intakes was 0.40 for FFQ1 and 0.39 for FFQ2, highest for calcium and iron, and lowest for energy and carbohydrates. Significant associations were observed between urinary isoflavones and soy protein intake ( r = 0.46), serum carotenoids and fruit and vegetable intake ( r = 0.34), plasma eicosapentaenoic acid and docosahexaenoic acid (EPA + DHA) and fish/seafood intake ( r = 0.36), and plasma odd chain saturated fatty acids (SFA) and dairy fat intake ( r = 0.25). Associations between plasma EPA + DHA and fish/seafood intake were consistent across ethnic groups ( r = 0.28-0.49), while differences were observed for other associations. FFQ assessment of dietary intakes in modern cosmopolitan populations remains feasible for the purpose of ranking individuals' dietary exposures in epidemiological studies.

  14. Reliable and fast volumetry of the lumbar spinal cord using cord image analyser (Cordial).

    PubMed

    Tsagkas, Charidimos; Altermatt, Anna; Bonati, Ulrike; Pezold, Simon; Reinhard, Julia; Amann, Michael; Cattin, Philippe; Wuerfel, Jens; Fischer, Dirk; Parmar, Katrin; Fischmann, Arne

    2018-04-30

    To validate the precision and accuracy of the semi-automated cord image analyser (Cordial) for lumbar spinal cord (SC) volumetry in 3D T1w MRI data of healthy controls (HC). 40 3D T1w images of 10 HC (w/m: 6/4; age range: 18-41 years) were acquired at one 3T-scanner in two MRI sessions (time interval 14.9±6.1 days). Each subject was scanned twice per session, allowing determination of test-retest reliability both in back-to-back (intra-session) and scan-rescan images (inter-session). Cordial was applied for lumbar cord segmentation twice per image by two raters, allowing for assessment of intra- and inter-rater reliability, and compared to a manual gold standard. While manually segmented volumes were larger (mean: 2028±245 mm 3 vs. Cordial: 1636±300 mm 3 , p<0.001), accuracy assessments between manually and semi-automatically segmented images showed a mean Dice-coefficient of 0.88±0.05. Calculation of within-subject coefficients of variation (COV) demonstrated high intra-session (1.22-1.86%), inter-session (1.26-1.84%), as well as intra-rater (1.73-1.83%) reproducibility. No significant difference was shown between intra- and inter-session reproducibility or between intra-rater reliabilities. Although inter-rater reproducibility (COV: 2.87%) was slightly lower compared to all other reproducibility measures, between rater consistency was very strong (intraclass correlation coefficient: 0.974). While under-estimating the lumbar SCV, Cordial still provides excellent inter- and intra-session reproducibility showing high potential for application in longitudinal trials. • Lumbar spinal cord segmentation using the semi-automated cord image analyser (Cordial) is feasible. • Lumbar spinal cord is 40-mm cord segment 60 mm above conus medullaris. • Cordial provides excellent inter- and intra-session reproducibility in lumbar spinal cord region. • Cordial shows high potential for application in longitudinal trials.

  15. Reproducible diagnosis of chronic lymphocytic leukemia by flow cytometry: An European Research Initiative on CLL (ERIC) & European Society for Clinical Cell Analysis (ESCCA) Harmonisation project

    PubMed Central

    Kreuzer, Karl‐Anton; Soosapilla, Asha; Spacek, Martin; Stehlikova, Olga; Gambell, Peter; McIver‐Brown, Neil; Villamor, Neus; Psarra, Katherina; Arroz, Maria; Milani, Raffaella; de la Serna, Javier; Cedena, M. Teresa; Jaksic, Ozren; Nomdedeu, Josep; Moreno, Carol; Rigolin, Gian Matteo; Cuneo, Antonio; Johansen, Preben; Johnsen, Hans E.; Rosenquist, Richard; Niemann, Carsten Utoft; Kern, Wolfgang; Westerman, David; Trneny, Marek; Mulligan, Stephen; Doubek, Michael; Pospisilova, Sarka; Hillmen, Peter; Oscier, David; Hallek, Michael; Ghia, Paolo; Montserrat, Emili

    2018-01-01

    The diagnostic criteria for CLL rely on morphology and immunophenotype. Current approaches have limitations affecting reproducibility and there is no consensus on the role of new markers. The aim of this project was to identify reproducible criteria and consensus on markers recommended for the diagnosis of CLL. ERIC/ESCCA members classified 14 of 35 potential markers as “required” or “recommended” for CLL diagnosis, consensus being defined as >75% and >50% agreement, respectively. An approach to validate “required” markers using normal peripheral blood was developed. Responses were received from 150 participants with a diagnostic workload >20 CLL cases per week in 23/150 (15%), 5–20 in 82/150 (55%), and <5 cases per week in 45/150 (30%). The consensus for “required” diagnostic markers included: CD19, CD5, CD20, CD23, Kappa, and Lambda. “Recommended” markers potentially useful for differential diagnosis were: CD43, CD79b, CD81, CD200, CD10, and ROR1. Reproducible criteria for component reagents were assessed retrospectively in 14,643 cases from 13 different centers and showed >97% concordance with current approaches. A pilot study to validate staining quality was completed in 11 centers. Markers considered as “required” for the diagnosis of CLL by the participants in this study (CD19, CD5, CD20, CD23, Kappa, and Lambda) are consistent with current diagnostic criteria and practice. Importantly, a reproducible approach to validate and apply these markers in individual laboratories has been identified. Finally, a consensus “recommended” panel of markers to refine diagnosis in borderline cases (CD43, CD79b, CD81, CD200, CD10, and ROR1) has been defined and will be prospectively evaluated. © 2017 International Clinical Cytometry Society PMID:29024461

  16. Reproducible diagnosis of chronic lymphocytic leukemia by flow cytometry: An European Research Initiative on CLL (ERIC) & European Society for Clinical Cell Analysis (ESCCA) Harmonisation project.

    PubMed

    Rawstron, Andy C; Kreuzer, Karl-Anton; Soosapilla, Asha; Spacek, Martin; Stehlikova, Olga; Gambell, Peter; McIver-Brown, Neil; Villamor, Neus; Psarra, Katherina; Arroz, Maria; Milani, Raffaella; de la Serna, Javier; Cedena, M Teresa; Jaksic, Ozren; Nomdedeu, Josep; Moreno, Carol; Rigolin, Gian Matteo; Cuneo, Antonio; Johansen, Preben; Johnsen, Hans E; Rosenquist, Richard; Niemann, Carsten Utoft; Kern, Wolfgang; Westerman, David; Trneny, Marek; Mulligan, Stephen; Doubek, Michael; Pospisilova, Sarka; Hillmen, Peter; Oscier, David; Hallek, Michael; Ghia, Paolo; Montserrat, Emili

    2018-01-01

    The diagnostic criteria for CLL rely on morphology and immunophenotype. Current approaches have limitations affecting reproducibility and there is no consensus on the role of new markers. The aim of this project was to identify reproducible criteria and consensus on markers recommended for the diagnosis of CLL. ERIC/ESCCA members classified 14 of 35 potential markers as "required" or "recommended" for CLL diagnosis, consensus being defined as >75% and >50% agreement, respectively. An approach to validate "required" markers using normal peripheral blood was developed. Responses were received from 150 participants with a diagnostic workload >20 CLL cases per week in 23/150 (15%), 5-20 in 82/150 (55%), and <5 cases per week in 45/150 (30%). The consensus for "required" diagnostic markers included: CD19, CD5, CD20, CD23, Kappa, and Lambda. "Recommended" markers potentially useful for differential diagnosis were: CD43, CD79b, CD81, CD200, CD10, and ROR1. Reproducible criteria for component reagents were assessed retrospectively in 14,643 cases from 13 different centers and showed >97% concordance with current approaches. A pilot study to validate staining quality was completed in 11 centers. Markers considered as "required" for the diagnosis of CLL by the participants in this study (CD19, CD5, CD20, CD23, Kappa, and Lambda) are consistent with current diagnostic criteria and practice. Importantly, a reproducible approach to validate and apply these markers in individual laboratories has been identified. Finally, a consensus "recommended" panel of markers to refine diagnosis in borderline cases (CD43, CD79b, CD81, CD200, CD10, and ROR1) has been defined and will be prospectively evaluated. © 2017 International Clinical Cytometry Society. © 2017 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society.

  17. Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study.

    PubMed

    Engelberger, Rolf P; Blazek, Claudia; Amsler, Felix; Keo, Hong H; Baumann, Frédéric; Blättler, Werner; Baumgartner, Iris; Willenberg, Torsten

    2011-10-05

    Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

  18. Phosphotyrosine-based-phosphoproteomics scaled-down to biopsy level for analysis of individual tumor biology and treatment selection.

    PubMed

    Labots, Mariette; van der Mijn, Johannes C; Beekhof, Robin; Piersma, Sander R; de Goeij-de Haas, Richard R; Pham, Thang V; Knol, Jaco C; Dekker, Henk; van Grieken, Nicole C T; Verheul, Henk M W; Jiménez, Connie R

    2017-06-06

    Mass spectrometry-based phosphoproteomics of cancer cell and tissue lysates provides insight in aberrantly activated signaling pathways and potential drug targets. For improved understanding of individual patient's tumor biology and to allow selection of tyrosine kinase inhibitors in individual patients, phosphoproteomics of small clinical samples should be feasible and reproducible. We aimed to scale down a pTyr-phosphopeptide enrichment protocol to biopsy-level protein input and assess reproducibility and applicability to tumor needle biopsies. To this end, phosphopeptide immunoprecipitation using anti-phosphotyrosine beads was performed using 10, 5 and 1mg protein input from lysates of colorectal cancer (CRC) cell line HCT116. Multiple needle biopsies from 7 human CRC resection specimens were analyzed at the 1mg-level. The total number of phosphopeptides captured and detected by LC-MS/MS ranged from 681 at 10mg input to 471 at 1mg HCT116 protein. ID-reproducibility ranged from 60.5% at 10mg to 43.9% at 1mg. Per 1mg-level biopsy sample, >200 phosphopeptides were identified with 57% ID-reproducibility between paired tumor biopsies. Unsupervised analysis clustered biopsies from individual patients together and revealed known and potential therapeutic targets. This study demonstrates the feasibility of label-free pTyr-phosphoproteomics at the tumor biopsy level based on reproducible analyses using 1mg of protein input. The considerable number of identified phosphopeptides at this level is attributed to an effective down-scaled immuno-affinity protocol as well as to the application of ID propagation in the data processing and analysis steps. Unsupervised cluster analysis reveals patient-specific profiles. Together, these findings pave the way for clinical trials in which pTyr-phosphoproteomics will be performed on pre- and on-treatment biopsies. Such studies will improve our understanding of individual tumor biology and may enable future pTyr-phosphoproteomics-based personalized medicine. Copyright © 2017. Published by Elsevier B.V.

  19. Improving Writing: Resources, Strategies, Assessments.

    ERIC Educational Resources Information Center

    Lenski, Susan Davis; Johns, Jerry L.

    Comprehensive and practical, this book provides resources, strategies, and assessments that seamlessly weave writing into everyday classroom routines. The resources in the book include reproducible student worksheets, transparency masters, teacher and student examples, and technology tips in the form of Web site addresses. Strategies throughout…

  20. Standardization of whole slide image morphologic assessment with definition of a new application: Digital slide dynamic morphometry.

    PubMed

    Puppa, Giacomo; Risio, Mauro; Sheahan, Kieran; Vieth, Michael; Zlobec, Inti; Lugli, Alessandro; Pecori, Sara; Wang, Lai Mun; Langner, Cord; Mitomi, Hiroyuki; Nakamura, Takatoshi; Watanabe, Masahiko; Ueno, Hideki; Chasle, Jacques; Senore, Carlo; Conley, Stephen A; Herlin, Paulette; Lauwers, Gregory Y

    2011-01-01

    In histopathology, the quantitative assessment of various morphologic features is based on methods originally conceived on specific areas observed through the microscope used. Failure to reproduce the same reference field of view using a different microscope will change the score assessed. Visualization of a digital slide on a screen through a dedicated viewer allows selection of the magnification. However, the field of view is rectangular, unlike the circular field of optical microscopy. In addition, the size of the selected area is not evident, and must be calculated. A digital slide morphometric system was conceived to reproduce the various methods published for assessing tumor budding in colorectal cancer. Eighteen international experts in colorectal cancer were invited to participate in a web-based study by assessing tumor budding with five different methods in 100 digital slides. The specific areas to be tested by each method were marked by colored circles. The areas were grouped in a target-like pattern and then saved as an .xml file. When a digital slide was opened, the .xml file was imported in order to perform the measurements. Since the morphometric tool is composed of layers that can be freely moved on top of the digital slide, the technique was named digital slide dynamic morphometry. Twelve investigators completed the task, the majority of them performing the multiple evaluations of each of the cases in less than 12 minutes. Digital slide dynamic morphometry has various potential applications and might be a useful tool for the assessment of histologic parameters originally conceived for optical microscopy that need to be quantified.

  1. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    PubMed

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, G; Trakul, N; Chang, E

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproduciblemore » position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.« less

  3. Reproducibility of onset and recovery oxygen uptake kinetics in moderately impaired patients with chronic heart failure

    PubMed Central

    De Vries, Wouter R.; Hoogeveen, Adwin R.; Zonderland, Maria L.; Thijssen, Eric J. M.; Schep, Goof

    2007-01-01

    Oxygen (O2) kinetics reflect the ability to adapt to or recover from exercise that is indicative of daily life. In patients with chronic heart failure (CHF), parameters of O2 kinetics have shown to be useful for clinical purposes like grading of functional impairment and assessment of prognosis. This study compared the goodness of fit and reproducibility of previously described methods to assess O2 kinetics in these patients. Nineteen CHF patients, New York Heart Association class II–III, performed two constant-load tests on a cycle ergometer at 50% of the maximum workload. Time constants of O2 onset- and recovery kinetics (τ) were calculated by mono-exponential modeling with four different sampling intervals (5 and 10 s, 5 and 8 breaths). The goodness of fit was expressed as the coefficient of determination (R2). Onset kinetics were also evaluated by the mean response time (MRT). Considering O2 onset kinetics, τ showed a significant inverse correlation with peak- \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} $$ \\ifmmode\\expandafter\\dot\\else\\expandafter\\.\\fi{V}{\\text{O}}_{2} $$\\end{document} (R = −0.88, using 10 s sampling intervals). The limits of agreement of both τ and MRT, however, were not clinically acceptable. O2 recovery kinetics yielded better reproducibility and goodness of fit. Using the most optimal sampling interval (5 breaths), a change of at least 13 s in τ is needed to exceed normal test-to-test variations. In conclusion, O2 recovery kinetics are more reproducible for clinical purposes than O2 onset kinetics in moderately impaired patients with CHF. It should be recognized that this observation cannot be assumed to be generalizable to more severely impaired CHF patients. PMID:17277937

  4. Normal values for myocardial deformation within the right heart measured by feature-tracking cardiovascular magnetic resonance imaging.

    PubMed

    Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P

    2018-02-01

    Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Relative validity of micronutrient and fiber intake assessed with two new interactive meal- and Web-based food frequency questionnaires.

    PubMed

    Christensen, Sara E; Möller, Elisabeth; Bonn, Stephanie E; Ploner, Alexander; Bälter, Olle; Lissner, Lauren; Bälter, Katarina

    2014-02-21

    The meal- and Web-based food frequency questionnaires, Meal-Q and MiniMeal-Q, were developed for cost-efficient assessment of dietary intake in epidemiological studies. The objective of this study was to evaluate the relative validity of micronutrient and fiber intake assessed with Meal-Q and MiniMeal-Q. The reproducibility of Meal-Q was also evaluated. A total of 163 volunteer men and women aged between 20 and 63 years were recruited from Stockholm County, Sweden. Assessment of micronutrient and fiber intake with the 174-item Meal-Q was compared to a Web-based 7-day weighed food record (WFR). Two administered Meal-Q questionnaires were compared for reproducibility. The 126-item MiniMeal-Q, developed after the validation study, was evaluated in a simulated validation by using truncated Meal-Q data. The study population consisted of approximately 80% women (129/163) with a mean age of 33 years (SD 12) who were highly educated (130/163, 80% with >12 years of education) on average. Cross-classification of quartiles with the WFR placed 69% to 90% in the same/adjacent quartile for Meal-Q and 67% to 89% for MiniMeal-Q. Bland-Altman plots with the WFR and the questionnaires showed large variances and a trend of increasing underestimation with increasing intakes. Deattenuated and energy-adjusted Spearman rank correlations between the questionnaires and the WFR were in the range ρ=.25-.69, excluding sodium that was not statistically significant. Cross-classifications of quartiles of the 2 Meal-Q administrations placed 86% to 97% in the same/adjacent quartile. Intraclass correlation coefficients for energy-adjusted intakes were in the range of .50-.76. With the exception of sodium, this validation study demonstrates Meal-Q and MiniMeal-Q to be useful methods for ranking micronutrient and fiber intake in epidemiological studies with Web-based data collection.

  6. Stress Reduction Through a Brief Writing Intervention With Women in Jail.

    PubMed

    Pankey, Tyson; Kelly, Patricia J; Ramaswamy, Megha

    2016-07-01

    To assess the feasibility/acceptability of writing as a stress reduction strategy with incarcerated women. The authors implemented a writing intervention in which six women wrote on topics of their choosing for 20 minutes on 5 consecutive days. Feasibility was assessed with investigator field notes; daily post-writing evaluations assessed intervention acceptability. The study also assessed the continuation of writing at 1-month postintervention and acceptability of instruments for evaluation of future interventions. Implementation barriers were minimal; participants voiced enthusiasm about the program and continued to write 3 to 4 days per week in the month postintervention. No problems were encountered in the completion of evaluation instruments. Writing is a feasible, reproducible stress relief intervention for incarcerated women. © The Author(s) 2016.

  7. Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy.

    PubMed

    Aquila, Iolanda; González, Ariana; Fernández-Golfín, Covadonga; Rincón, Luis Miguel; Casas, Eduardo; García, Ana; Hinojar, Rocio; Jiménez-Nacher, José Julio; Zamorano, José Luis

    2016-05-17

    3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.

  8. Reproducibility and Variation of Diffusion Measures in the Squirrel Monkey Brain, In Vivo and Ex Vivo

    PubMed Central

    Schilling, Kurt; Gao, Yurui; Stepniewska, Iwona; Choe, Ann S; Landman, Bennett A; Anderson, Adam W

    2016-01-01

    Purpose Animal models are needed to better understand the relationship between diffusion MRI (dMRI) and the underlying tissue microstructure. One promising model for validation studies is the common squirrel monkey, Saimiri sciureus. This study aims to determine (1) the reproducibility of in vivo diffusion measures both within and between subjects; (2) the agreement between in vivo and ex vivo data acquired from the same specimen and (3) normal diffusion values and their variation across brain regions. Methods Data were acquired from three healthy squirrel monkeys, each imaged twice in vivo and once ex vivo. Reproducibility of fractional anisotropy (FA), mean diffusivity (MD), and principal eigenvector (PEV) was assessed, and normal values were determined both in vivo and ex vivo. Results The calculated coefficients of variation (CVs) for both intra-subject and inter-subject MD were below 10% (low variability) while FA had a wider range of CVs, 2–14% intra-subject (moderate variability), and 3–31% inter-subject (high variability). MD in ex vivo tissue was lower than in vivo (30%–50% decrease), while FA values increased in all regions (30–39% increase). The mode of angular differences between in vivo and ex vivo PEVs was 12 degrees. Conclusion This study characterizes the diffusion properties of the squirrel monkey brain and serves as the groundwork for using the squirrel monkey, both in vivo and ex vivo, as a model for diffusion MRI studies. PMID:27587226

  9. Ocular volumetry using fast high-resolution MRI during visual fixation.

    PubMed

    Tanitame, K; Sone, T; Miyoshi, T; Tanitame, N; Otani, K; Akiyama, Y; Takasu, M; Date, S; Kiuchi, Y; Awai, K

    2013-04-01

    Volumetry may be useful for evaluating treatment response and prognosis of intraocular lesions. Phantom, volunteer, and patient studies were performed to determine whether ocular MR volumetry is reproducible. Half-Fourier single-shot RARE and FSPGR sequences at 1.5T with a 76-mm-diameter surface coil were optimized to obtain still ocular images. Volumetry accuracies of each sequence were compared with simulated subretinal phantom volumes. Ocular volumetry was performed in 15 volunteers twice in 1 week by using contiguous axial images of the globes while the subjects stared at a target, and images were acquired in 2 seconds before the subjects were instructed to blink, with this process repeated as necessary. Imaging, intraobserver, and interobserver reproducibility for volumes of the whole eyeball and anterior chamber were assessed. Ocular volumetry was also performed in 6 patients with intraocular tumors before and after treatment. The phantom study demonstrated that measurement error rates with RARE were significantly lower than with FSPGR (P<.01). The volunteer study demonstrated excellent imaging and intraobserver reproducibility of RARE volumetry for whole eyeballs and anterior chambers (P<.01). Although no interobserver differences were observed in anterior chamber volume measurement (P=.33), there was a significant difference between the 2 observers in eyeball volume measurement (P<.01). Follow-up volumetric data were useful for treatment decisions in all patients. Ocular volumetry from contiguous ultrafast RARE images obtained during visual fixation is feasible in volunteer and patient studies and is superior to FSPGR images.

  10. Validity and reproducibility of cephalometric measurements obtained from digital photographs of analogue headfilms.

    PubMed

    Grybauskas, Simonas; Balciuniene, Irena; Vetra, Janis

    2007-01-01

    The emerging market of digital cephalographs and computerized cephalometry is overwhelming the need to examine the advantages and drawbacks of manual cephalometry, meanwhile, small offices continue to benefit from the economic efficacy and ease of use of analogue cephalograms. The use of modern cephalometric software requires import of digital cephalograms or digital capture of analogue data: scanning and digital photography. The validity of digital photographs of analogue headfilms rather than original headfilms in clinical practice has not been well established. Digital photography could be a fast and inexpensive method of digital capture of analogue cephalograms for use in digital cephalometry. The objective of this study was to determine the validity and reproducibility of measurements obtained from digital photographs of analogue headfilms in lateral cephalometry. Analogue cephalometric radiographs were performed on 15 human dry skulls. Each of them was traced on acetate paper and photographed three times independently. Acetate tracings and digital photographs were digitized and analyzed in cephalometric software. Linear regression model, paired t-test intergroup analysis and coefficient of repeatability were used to assess validity and reproducibility for 63 angular, linear and derivative measurements. 54 out of 63 measurements were determined to have clinically acceptable reproducibility in the acetate tracing group as well as 46 out of 63 in the digital photography group. The worst reproducibility was determined for measurements dependent on landmarks of incisors and poorly defined outlines, majority of them being angular measurements. Validity was acceptable for all measurements, and although statistically significant differences between methods existed for as many as 15 parameters, they appeared to be clinically insignificant being smaller than 1 unit of measurement. Validity was acceptable for 59 of 63 measurements obtained from digital photographs, substantiating the use of digital photography for headfilm capture and computer-aided cephalometric analysis.

  11. Reproducibility of R-fMRI metrics on the impact of different strategies for multiple comparison correction and sample sizes.

    PubMed

    Chen, Xiao; Lu, Bin; Yan, Chao-Gan

    2018-01-01

    Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. Assessment of the performance of numerical modeling in reproducing a replenishment of sediments in a water-worked channel

    NASA Astrophysics Data System (ADS)

    Juez, C.; Battisacco, E.; Schleiss, A. J.; Franca, M. J.

    2016-06-01

    The artificial replenishment of sediment is used as a method to re-establish sediment continuity downstream of a dam. However, the impact of this technique on the hydraulics conditions, and resulting bed morphology, is yet to be understood. Several numerical tools have been developed during last years for modeling sediment transport and morphology evolution which can be used for this application. These models range from 1D to 3D approaches: the first being over simplistic for the simulation of such a complex geometry; the latter requires often a prohibitive computational effort. However, 2D models are computationally efficient and in these cases may already provide sufficiently accurate predictions of the morphology evolution caused by the sediment replenishment in a river. Here, the 2D shallow water equations in combination with the Exner equation are solved by means of a weak-coupled strategy. The classical friction approach considered for reproducing the bed channel roughness has been modified to take into account the morphological effect of replenishment which provokes a channel bed fining. Computational outcomes are compared with four sets of experimental data obtained from several replenishment configurations studied in the laboratory. The experiments differ in terms of placement volume and configuration. A set of analysis parameters is proposed for the experimental-numerical comparison, with particular attention to the spreading, covered surface and travel distance of placed replenishment grains. The numerical tool is reliable in reproducing the overall tendency shown by the experimental data. The effect of fining roughness is better reproduced with the approach herein proposed. However, it is also highlighted that the sediment clusters found in the experiment are not well numerically reproduced in the regions of the channel with a limited number of sediment grains.

  13. Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T.

    PubMed

    Prinsen, Hetty; de Graaf, Robin A; Mason, Graeme F; Pelletier, Daniel; Juchem, Christoph

    2017-01-01

    To determine the reproducibility of a comprehensive single-session measurement of glutathione (GSH), γ-aminobutyric acid (GABA), glutamate, and other biochemicals implicated in the pathophysiology of multiple sclerosis (MS) in the human brain with 1 H magnetic resonance spectroscopy (MRS). Five healthy subjects were studied twice in separate 1-hour sessions at 7T. One MS patient was also scanned once. GSH and GABA were measured with J-difference editing using a semilocalized by adiabatic selective refocusing sequence (semi-LASER, TE = 72 msec). A stimulated echo acquisition mode sequence (STEAM, TE = 10 msec) was used to detect glutamate along with the overall biochemical profile. Spectra were quantified with LCModel. Quantification accuracy was assessed through Cramer-Rao lower bounds (CRLB). Reproducibility of the metabolite quantification was tested using coefficients of variation (CoV). CRLB were ≤7% for GSH, GABA, and glutamate and average CoV of 7.8 ± 3.2%, 9.5 ± 7.0%, and 3.2 ± 1.7% were achieved, respectively. The average test/retest concentration differences at this measurement reproducibility and quantification accuracy were smaller for GABA and glutamate than intersubject variations in metabolite content with CoV ratios of 0.6 and 0.8, respectively. As proof of principle, GSH, GABA, and glutamate were also detected in an MS patient. GSH, GABA, glutamate, and other metabolites relevant in MS can be quantified at 7T with high accuracy and reproducibility in a single 1-hour session. This methodology might serve as a clinical research tool to investigate biochemical markers associated with MS. 2 J. Magn. Reson. Imaging 2017;45:187-198. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Image quality stability of whole-body diffusion weighted imaging.

    PubMed

    Chen, Yun-bin; Hu, Chun-miao; Zhong, Jing; Sun, Fei

    2009-06-01

    To assess the reproducibility of whole-body diffusion weighted imaging (WB-DWI) technique in healthy volunteers under normal breathing with background body signal suppression. WB-DWI was performed on 32 healthy volunteers twice within two-week period using short TI inversion-recovery diffusion-weighted echo-planar imaging sequence and built-in body coil. The volunteers were scanned across six stations continuously covering the entire body from the head to the feet under normal breathing. The bone apparent diffusion coefficient (ADC) and exponential ADC (eADC) of regions of interest (ROIs) were measured. We analyzed correlation of the results using paired-t-test to assess the reproducibility of the WB-DWI technique. We were successful in collecting and analyzing data of 64 WB-DWI images. There was no significant difference in bone ADC and eADC of 824 ROIs between the paired observers and paired scans (P>0.05). Most of the images from all stations were of diagnostic quality. The measurements of bone ADC and eADC have good reproducibility. WB-DWI technique under normal breathing with background body signal suppression is adequate.

  15. A theoretical and experimental benchmark study of core-excited states in nitrogen

    DOE PAGES

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan; ...

    2018-02-14

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. In conclusion, the computationalmore » results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.« less

  16. A theoretical and experimental benchmark study of core-excited states in nitrogen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myhre, Rolf H.; Wolf, Thomas J. A.; Cheng, Lan

    The high resolution near edge X-ray absorption fine structure spectrum of nitrogen displays the vibrational structure of the core-excited states. This makes nitrogen well suited for assessing the accuracy of different electronic structure methods for core excitations. We report high resolution experimental measurements performed at the SOLEIL synchrotron facility. These are compared with theoretical spectra calculated using coupled cluster theory and algebraic diagrammatic construction theory. The coupled cluster singles and doubles with perturbative triples model known as CC3 is shown to accurately reproduce the experimental excitation energies as well as the spacing of the vibrational transitions. In conclusion, the computationalmore » results are also shown to be systematically improved within the coupled cluster hierarchy, with the coupled cluster singles, doubles, triples, and quadruples method faithfully reproducing the experimental vibrational structure.« less

  17. NetBenchmark: a bioconductor package for reproducible benchmarks of gene regulatory network inference.

    PubMed

    Bellot, Pau; Olsen, Catharina; Salembier, Philippe; Oliveras-Vergés, Albert; Meyer, Patrick E

    2015-09-29

    In the last decade, a great number of methods for reconstructing gene regulatory networks from expression data have been proposed. However, very few tools and datasets allow to evaluate accurately and reproducibly those methods. Hence, we propose here a new tool, able to perform a systematic, yet fully reproducible, evaluation of transcriptional network inference methods. Our open-source and freely available Bioconductor package aggregates a large set of tools to assess the robustness of network inference algorithms against different simulators, topologies, sample sizes and noise intensities. The benchmarking framework that uses various datasets highlights the specialization of some methods toward network types and data. As a result, it is possible to identify the techniques that have broad overall performances.

  18. Reproducibility of an in-laboratory test meal to assess ad libitum energy intake in adolescents with obesity.

    PubMed

    Thivel, David; Genin, Pauline Manon; Mathieu, Marie-Eve; Pereira, Bruno; Metz, Lore

    2016-10-01

    The aim of the present work was to test the reproducibility of a personalized in-laboratory ad libitum buffet meal in assessing energy and macronutrient intake in obese adolescents. Twelve 13.5 ± 1.5 years old obese adolescent girls were asked to complete three identical experimental sessions during which an ad libitum buffet meal was presented at lunch time. The buffet was personalized based on food preference questionnaires, presented usually consumed food items and excluded preferred foods. Total energy intake and the energy ingested derived from each macronutrient were assessed by investigators using the Bilnuts nutritional software. Mean body mass was 87.0 ± 13.7 kg and mean BMI was 32.2 ± 4.9 kg/m(2). Mean FM percentage was 39.1 ± 4.4% and FFM was 50.6 ± 7.7 kg. There was no significant difference between total energy intake, the percentage of intake related to fat, protein or Carbohydrates (CHO) between the three sessions. The Intraclass Correlations (ICC) observed for total energy intake was 0.99. ICC for Protein, Fat and CHO were 0.38; 0.96 and 0.81 respectively. The Bland & Altman visual analysis revealed an important agreement between meals. The proposed personalized in-laboratory ad libitum test meal produces is a reproducible methods to assess energy and macronutrients intake in obese adolescent girls. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Inconsistent Strategies to Spin up Models in CMIP5: Implications for Ocean Biogeochemical Model Performance Assessment

    NASA Technical Reports Server (NTRS)

    Seferian, Roland; Gehlen, Marion; Bopp, Laurent; Resplandy, Laure; Orr, James C.; Marti, Olivier; Dunne, John P.; Christian, James R.; Doney, Scott C.; Ilyina, Tatiana; hide

    2015-01-01

    During the fifth phase of the Coupled Model Intercomparison Project (CMIP5) substantial efforts were made to systematically assess the skill of Earth system models. One goal was to check how realistically representative marine biogeochemical tracer distributions could be reproduced by models. In routine assessments model historical hindcasts were compared with available modern biogeochemical observations. However, these assessments considered neither how close modeled biogeochemical reservoirs were to equilibrium nor the sensitivity of model performance to initial conditions or to the spin-up protocols. Here, we explore how the large diversity in spin-up protocols used for marine biogeochemistry in CMIP5 Earth system models (ESMs) contributes to model-to-model differences in the simulated fields. We take advantage of a 500-year spin-up simulation of IPSL-CM5A-LR to quantify the influence of the spin-up protocol on model ability to reproduce relevant data fields. Amplification of biases in selected biogeochemical fields (O2, NO3, Alk-DIC) is assessed as a function of spin-up duration. We demonstrate that a relationship between spin-up duration and assessment metrics emerges from our model results and holds when confronted with a larger ensemble of CMIP5 models. This shows that drift has implications for performance assessment in addition to possibly aliasing estimates of climate change impact. Our study suggests that differences in spin-up protocols could explain a substantial part of model disparities, constituting a source of model-to- model uncertainty. This requires more attention in future model intercomparison exercises in order to provide quantitatively more correct ESM results on marine biogeochemistry and carbon cycle feedbacks.

  20. Assessment of carotid stiffness and intima-media thickness from ultrasound data: comparison between two methods.

    PubMed

    Bianchini, Elisabetta; Bozec, Erwan; Gemignani, Vincenzo; Faita, Francesco; Giannarelli, Chiara; Ghiadoni, Lorenzo; Demi, Marcello; Boutouyrie, Pierre; Laurent, Stéphane

    2010-08-01

    Increased arterial stiffness and carotid intima-media thickness (IMT) are considered independent predictors of cardiovascular events. The aim of this study was to compare a system recently developed in our laboratory for automatic assessment of these parameters from ultrasound image sequences to a reference radio frequency (RF) echo-tracking system. Common carotid artery scans of 21 patients with cardiovascular risk factors and 12 healthy volunteers were analyzed by both devices for the assessment of diameter (D), IMT, and distension (DeltaD). In the healthy volunteers, analyses were repeated twice to evaluate intraobserver variability. Agreement was evaluated by Bland-Altman analysis, whereas reproducibility was expressed as a coefficient of variation (CV). Regarding the agreement between the two systems, bias values +/- SD were 0.060 +/- 0.110 mm for D, -0.006 +/- 0.039 mm for IMT, and -0.016 +/- 0.039 mm for DeltaD. Intraobserver CVs were 2% +/- 2% for D, 5% +/- 5% for IMT, and 6% +/- 6% for DeltaD with the RF echo-tracking system and 2% +/- 1% for D, 6% +/- 6% for IMT, and 8% +/- 6% for DeltaD with our automated system. Although B-mode-based devices are less precise than RF-based ones, our automated system has good agreement with the reference method and comparable reproducibility, at least when high-quality images are analyzed. Hence, this study suggests that the presented system based on image processing from standard ultrasound scans is a suitable device for measuring IMT and local arterial stiffness parameters in clinical studies.

  1. The biomarker-based validity of a brief-type diet history questionnaire for estimating eicosapentaenoic acid and docosahexaenoic acid intakes in pregnant Japanese women.

    PubMed

    Shiraishi, Mie; Haruna, Megumi; Matsuzaki, Masayo; Murayama, Ryoko; Sasaki, Satoshi

    2015-01-01

    Maternal docosahexaenoic acid (DHA) intakes is important for brain development in fetuses. Accurate assessment of EPA and DHA intakes is required in clinical settings to identify women with deficiency of these nutrients and provide an appropriate intervention for them. We examined the validity and reproducibility of a brief-type self-administered diet history questionnaire (BDHQ) for evaluating EPA and DHA intakes of pregnant Japanese women, to establish an easily administered dietary assessment tool. A total of 105 women in the second trimester and 102 women in the third trimester were studied at a university hospital in Tokyo, between November 2010 and February 2012. The reference values for the validation study were plasma concentrations of EPA and DHA. For the reproducibility study, 54 women completed the BDHQ twice, within a 4-week period in the second trimester. Energy-adjusted intakes of EPA, DHA, and EPA+DHA were significantly associated with the corresponding plasma concentrations (rs=0.354, rs=0.305, and rs=0.327 in the second trimester; rs=0.391, rs=0.316, and rs=0.358 in the third trimester, respectively). Intraclass correlation coefficients for the two-time BDHQ were 0.543 (EPA), 0.611 (DHA), and 0.581 (EPA+DHA). In the Bland-Altman plots, the intakes of EPA, DHA, and EPA+DHA in the two-time BDHQ showed that the values for most participants were in the accepted range of agreement. BDHQ has an acceptable validity level for assessing EPA and DHA intakes among Japanese women in the second and third trimesters.

  2. Assessment of pulmonary vascular reactivity to oxygen using fractional moving blood volume in fetuses with normal lung development and pulmonary hypoplasia in congenital diaphragmatic hernia.

    PubMed

    DeKoninck, Philip; Jimenez, Julio; Russo, Francesca M; Hodges, Ryan; Gratacós, Eduard; Deprest, Jan

    2014-10-01

    The objective of this study is to evaluate whether assessment pulmonary vascular reactivity in response to maternal hyperoxygenation using fractional moving blood volume (FMBV) is associated with lesser variability between individual measurements than what is observed with direct Doppler measurements. Forty-five measurements were performed in 15 singleton fetuses with normal lung development at three time points in the latter half of pregnancy (range: 25.9-36.7 weeks). We further evaluated five fetuses with severe congenital diaphragmatic hernia. Lung perfusion was assessed using power Doppler ultrasound, and images were stored for offline FMBV calculation, both at base line and during oxygen administration (9 L/min for 10 min). The proportionate difference between both measurements is further referred to as deltaFMBV. Overall, 91% of images were of sufficient quality for further analysis. There was no correlation between pulmonary reactivity to oxygen (deltaFMBV) and gestational age in controls (12.9 ± 32.1%). Moreover, deltaFMBV showed large variability between subjects, as well as within the same fetus throughout gestation. We observed good intraobserver (0.88; 0.84) and interobserver (0.88; 0.77) reproducibility for both controls and congenital diaphragmatic hernia, respectively (intraclass correlation coefficients). Despite being a reproducible method to study the lung vasculature, the large variability of FMBV following hyperoxygenation limits its clinical translation. © 2014 John Wiley & Sons, Ltd.

  3. A Comprehensive Histological Assessment of Osteoarthritis Lesions in Mice

    PubMed Central

    McNulty, Margaret A.; Loeser, Richard F.; Davey, Cynthia; Callahan, Michael F.; Ferguson, Cristin M.; Carlson, Cathy S.

    2011-01-01

    Objective: Accurate histological assessment of osteoarthritis (OA) is critical in studies evaluating the effects of interventions on disease severity. The purpose of the present study was to develop a histological grading scheme that comprehensively and quantitatively assesses changes in multiple tissues that are associated with OA of the stifle joint in mice. Design: Two representative midcoronal sections from 158 stifle joints, including naturally occurring and surgically induced OA, were stained with H&E and Safranin-O stains. All slides were evaluated to characterize the changes present. A grading scheme that includes both measurements and semiquantitative scores was developed, and principal components analysis (PCA) was applied to the resulting data from the medial tibial plateaus. A subset of 30 tibial plateaus representing a wide range of severity was then evaluated by 4 observers. Reliability of the results was evaluated using intraclass correlation coefficients (ICCs) and area under the receiver operating characteristic (ROC) curve. Results: Five factors were retained by PCA, accounting for 74% of the total variance. Interobserver and intraobserver reproducibilities for evaluations of articular cartilage and subchondral bone were acceptable. The articular cartilage integrity and chondrocyte viability factor scores were able to distinguish severe OA from normal, minimal, mild, and moderate disease. Conclusion: This newly developed grading scheme and resulting factors characterize a range of joint changes in mouse stifle joints that are associated with OA. Overall, the newly developed scheme is reliable and reproducible, characterizes changes in multiple tissues, and provides comprehensive information regarding a specific site in the stifle joint. PMID:26069594

  4. A novel model of human skin pressure ulcers in mice.

    PubMed

    Maldonado, Andrés A; Cristóbal, Lara; Martín-López, Javier; Mallén, Mar; García-Honduvilla, Natalio; Buján, Julia

    2014-01-01

    Pressure ulcers are a prevalent health problem in today's society. The shortage of suitable animal models limits our understanding and our ability to develop new therapies. This study aims to report on the development of a novel and reproducible human skin pressure ulcer model in mice. Male non-obese, diabetic, severe combined immunodeficiency mice (n = 22) were engrafted with human skin. A full-thickness skin graft was placed onto 4×3 cm wounds created on the dorsal skin of the mice. Two groups with permanent grafts were studied after 60 days. The control group (n = 6) was focused on the process of engraftment. Evaluations were conducted with photographic assessment, histological analysis and fluorescence in situ hybridization (FISH) techniques. The pressure ulcer group (n = 12) was created using a compression device. A pressure of 150 mmHg for 8 h, with a total of three cycles of compression-release was exerted. Evaluations were conducted with photographic assessment and histological analysis. Skin grafts in the control group took successfully, as shown by visual assessment, FISH techniques and histological analysis. Pressure ulcers in the second group showed full-thickness skin loss with damage and necrosis of all the epidermal and dermal layers (ulcer stage III) in all cases. Complete repair occurred after 40 days. An inexpensive, reproducible human skin pressure ulcer model has been developed. This novel model will facilitate the development of new clinically relevant therapeutic strategies that can be tested directly on human skin.

  5. Minimizing Interpolation Bias and Precision Error in In Vivo μCT-based Measurements of Bone Structure and Dynamics

    PubMed Central

    de Bakker, Chantal M. J.; Altman, Allison R.; Li, Connie; Tribble, Mary Beth; Lott, Carina; Tseng, Wei-Ju; Liu, X. Sherry

    2016-01-01

    In vivo μCT imaging allows for high-resolution, longitudinal evaluation of bone properties. Based on this technology, several recent studies have developed in vivo dynamic bone histomorphometry techniques that utilize registered μCT images to identify regions of bone formation and resorption, allowing for longitudinal assessment of bone remodeling. However, this analysis requires a direct voxel-by-voxel subtraction between image pairs, necessitating rotation of the images into the same coordinate system, which introduces interpolation errors. We developed a novel image transformation scheme, matched-angle transformation (MAT), whereby the interpolation errors are minimized by equally rotating both the follow-up and baseline images instead of the standard of rotating one image while the other remains fixed. This new method greatly reduced interpolation biases caused by the standard transformation. Additionally, our study evaluated the reproducibility and precision of bone remodeling measurements made via in vivo dynamic bone histomorphometry. Although bone remodeling measurements showed moderate baseline noise, precision was adequate to measure physiologically relevant changes in bone remodeling, and measurements had relatively good reproducibility, with intra-class correlation coefficients of 0.75-0.95. This indicates that, when used in conjunction with MAT, in vivo dynamic histomorphometry provides a reliable assessment of bone remodeling. PMID:26786342

  6. Minimizing Interpolation Bias and Precision Error in In Vivo µCT-Based Measurements of Bone Structure and Dynamics.

    PubMed

    de Bakker, Chantal M J; Altman, Allison R; Li, Connie; Tribble, Mary Beth; Lott, Carina; Tseng, Wei-Ju; Liu, X Sherry

    2016-08-01

    In vivo µCT imaging allows for high-resolution, longitudinal evaluation of bone properties. Based on this technology, several recent studies have developed in vivo dynamic bone histomorphometry techniques that utilize registered µCT images to identify regions of bone formation and resorption, allowing for longitudinal assessment of bone remodeling. However, this analysis requires a direct voxel-by-voxel subtraction between image pairs, necessitating rotation of the images into the same coordinate system, which introduces interpolation errors. We developed a novel image transformation scheme, matched-angle transformation (MAT), whereby the interpolation errors are minimized by equally rotating both the follow-up and baseline images instead of the standard of rotating one image while the other remains fixed. This new method greatly reduced interpolation biases caused by the standard transformation. Additionally, our study evaluated the reproducibility and precision of bone remodeling measurements made via in vivo dynamic bone histomorphometry. Although bone remodeling measurements showed moderate baseline noise, precision was adequate to measure physiologically relevant changes in bone remodeling, and measurements had relatively good reproducibility, with intra-class correlation coefficients of 0.75-0.95. This indicates that, when used in conjunction with MAT, in vivo dynamic histomorphometry provides a reliable assessment of bone remodeling.

  7. Characterization of Nanoparticle Batch-To-Batch Variability

    PubMed Central

    Mülhopt, Sonja; Dilger, Marco; Adelhelm, Christel; Anderlohr, Christopher; Gómez de la Torre, Johan; Langevin, Dominique; Mahon, Eugene; Piella, Jordi; Puntes, Victor; Ray, Sikha; Schneider, Reinhard; Wilkins, Terry; Weiss, Carsten

    2018-01-01

    A central challenge for the safe design of nanomaterials (NMs) is the inherent variability of NM properties, both as produced and as they interact with and evolve in, their surroundings. This has led to uncertainty in the literature regarding whether the biological and toxicological effects reported for NMs are related to specific NM properties themselves, or rather to the presence of impurities or physical effects such as agglomeration of particles. Thus, there is a strong need for systematic evaluation of the synthesis and processing parameters that lead to potential variability of different NM batches and the reproducible production of commonly utilized NMs. The work described here represents over three years of effort across 14 European laboratories to assess the reproducibility of nanoparticle properties produced by the same and modified synthesis routes for four of the OECD priority NMs (silica dioxide, zinc oxide, cerium dioxide and titanium dioxide) as well as amine-modified polystyrene NMs, which are frequently employed as positive controls for nanotoxicity studies. For 46 different batches of the selected NMs, all physicochemical descriptors as prioritized by the OECD have been fully characterized. The study represents the most complete assessment of NMs batch-to-batch variability performed to date and provides numerous important insights into the potential sources of variability of NMs and how these might be reduced. PMID:29738461

  8. Detection of Amine Impurity and Quality Assessment of the MALDI Matrix α-Cyano-4-Hydroxy-Cinnamic Acid for Peptide Analysis in the amol Range

    NASA Astrophysics Data System (ADS)

    Rechthaler, Justyna; Pittenauer, Ernst; Schaub, Tanner M.; Allmaier, Günter

    2013-05-01

    We have studied sample preparation conditions to increase the reproducibility of positive UV-MALDI-TOF mass spectrometry of peptides in the amol range. By evaluating several α-cyano-4-hydroxy-cinnamic acid (CHCA) matrix batches and preparation protocols, it became apparent that two factors have a large influence on the reproducibility and the quality of the generated peptide mass spectra: (1) the selection of the CHCA matrix, which allows the most sensitive measurements and an easier finding of the "sweet spots," and (2) the amount of the sample volume deposited onto the thin crystalline matrix layer. We have studied in detail the influence of a contaminant, coming from commercial CHCA matrix batches, on sensitivity of generated peptide mass spectra in the amol as well as fmol range of a tryptic peptide mixture. The structure of the contaminant, N, N-dimethylbutyl amine, was determined by applying MALDI-FT-ICR mass spectrometry experiments for elemental composition and MALDI high energy CID experiments utilizing a tandem mass spectrometer (TOF/RTOF). A recrystallization of heavily contaminated CHCA batches that reduces or eliminates the determined impurity is described. Furthermore, a fast and reliable method for the assessment of CHCA matrix batches prior to tryptic peptide MALDI mass spectrometric analyses is presented.

  9. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    PubMed

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. A new model of sperm nuclear architecture following assessment of the organization of centromeres and telomeres in three-dimensions.

    PubMed

    Ioannou, Dimitrios; Millan, Nicole M; Jordan, Elizabeth; Tempest, Helen G

    2017-01-31

    The organization of chromosomes in sperm nuclei has been proposed to possess a unique "hairpin-loop" arrangement, which is hypothesized to aid in the ordered exodus of the paternal genome following fertilization. This study simultaneously assessed the 3D and 2D radial and longitudinal organization of telomeres, centromeres, and investigated whether chromosomes formed the same centromere clusters in sperm cells. Reproducible radial and longitudinal non-random organization was observed for all investigated loci using both 3D and 2D approaches in multiple subjects. We report novel findings, with telomeres and centromeres being localized throughout the nucleus but demonstrating roughly a 1:1 distribution in the nuclear periphery and the intermediate regions with <15% occupying the nuclear interior. Telomeres and centromeres were observed to aggregate in sperm nuclei, forming an average of 20 and 7 clusters, respectively. Reproducible longitudinal organization demonstrated preferential localization of telomeres and centromeres in the mid region of the sperm cell. Preliminary evidence is also provided to support the hypothesis that specific chromosomes preferentially form the same centromere clusters. The more segmental distribution of telomeres and centromeres as described in this study could more readily accommodate and facilitate the sequential exodus of paternal chromosomes following fertilization.

  11. A new model of sperm nuclear architecture following assessment of the organization of centromeres and telomeres in three-dimensions

    PubMed Central

    Ioannou, Dimitrios; Millan, Nicole M.; Jordan, Elizabeth; Tempest, Helen G.

    2017-01-01

    The organization of chromosomes in sperm nuclei has been proposed to possess a unique “hairpin-loop” arrangement, which is hypothesized to aid in the ordered exodus of the paternal genome following fertilization. This study simultaneously assessed the 3D and 2D radial and longitudinal organization of telomeres, centromeres, and investigated whether chromosomes formed the same centromere clusters in sperm cells. Reproducible radial and longitudinal non-random organization was observed for all investigated loci using both 3D and 2D approaches in multiple subjects. We report novel findings, with telomeres and centromeres being localized throughout the nucleus but demonstrating roughly a 1:1 distribution in the nuclear periphery and the intermediate regions with <15% occupying the nuclear interior. Telomeres and centromeres were observed to aggregate in sperm nuclei, forming an average of 20 and 7 clusters, respectively. Reproducible longitudinal organization demonstrated preferential localization of telomeres and centromeres in the mid region of the sperm cell. Preliminary evidence is also provided to support the hypothesis that specific chromosomes preferentially form the same centromere clusters. The more segmental distribution of telomeres and centromeres as described in this study could more readily accommodate and facilitate the sequential exodus of paternal chromosomes following fertilization. PMID:28139771

  12. Statistical issues in the comparison of quantitative imaging biomarker algorithms using pulmonary nodule volume as an example.

    PubMed

    Obuchowski, Nancy A; Barnhart, Huiman X; Buckler, Andrew J; Pennello, Gene; Wang, Xiao-Feng; Kalpathy-Cramer, Jayashree; Kim, Hyun J Grace; Reeves, Anthony P

    2015-02-01

    Quantitative imaging biomarkers are being used increasingly in medicine to diagnose and monitor patients' disease. The computer algorithms that measure quantitative imaging biomarkers have different technical performance characteristics. In this paper we illustrate the appropriate statistical methods for assessing and comparing the bias, precision, and agreement of computer algorithms. We use data from three studies of pulmonary nodules. The first study is a small phantom study used to illustrate metrics for assessing repeatability. The second study is a large phantom study allowing assessment of four algorithms' bias and reproducibility for measuring tumor volume and the change in tumor volume. The third study is a small clinical study of patients whose tumors were measured on two occasions. This study allows a direct assessment of six algorithms' performance for measuring tumor change. With these three examples we compare and contrast study designs and performance metrics, and we illustrate the advantages and limitations of various common statistical methods for quantitative imaging biomarker studies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Robust tissue classification for reproducible wound assessment in telemedicine environments

    NASA Astrophysics Data System (ADS)

    Wannous, Hazem; Treuillet, Sylvie; Lucas, Yves

    2010-04-01

    In telemedicine environments, a standardized and reproducible assessment of wounds, using a simple free-handled digital camera, is an essential requirement. However, to ensure robust tissue classification, particular attention must be paid to the complete design of the color processing chain. We introduce the key steps including color correction, merging of expert labeling, and segmentation-driven classification based on support vector machines. The tool thus developed ensures stability under lighting condition, viewpoint, and camera changes, to achieve accurate and robust classification of skin tissues. Clinical tests demonstrate that such an advanced tool, which forms part of a complete 3-D and color wound assessment system, significantly improves the monitoring of the healing process. It achieves an overlap score of 79.3 against 69.1% for a single expert, after mapping on the medical reference developed from the image labeling by a college of experts.

  14. Echocardiographic assessment of left ventricular diastolic function.

    PubMed

    Pirat, Bahar; Zoghbi, William A

    2007-09-01

    Assessment of diastolic function and left ventricular filling pressures in the setting of both normal and reduced systolic function is of major importance particularly in patients with dyspnea. Since multiple echocardiography parameters are used to assess diastolic function each with some limitations, a comprehensive approach should be applied. Transmitral Doppler flow should be evaluated in combination with newer, less load dependent Doppler techniques. Tissue Doppler imaging provides accurate, well validated data regarding diastolic properties and filling pressures of the left ventricle. Tissue Doppler imaging should be the part of a routine echocardiography study due to its ease of use and high reproducibility. Pulmonary vein Doppler and flow propagation velocity should be incorporated into the evaluation when needed.

  15. Response assessment in neuro-oncology.

    PubMed

    Quant, Eudocia C; Wen, Patrick Y

    2011-02-01

    Accuracy and reproducibility in determining response to therapy and tumor progression can be difficult to achieve for nervous system tumors. Current response criteria vary depending on the pathology and have several limitations. Until recently, the most widely used criteria for gliomas were "Macdonald criteria," based on two-dimensional tumor measurements on neuroimaging studies. However, the Response Assessment in Neuro-Oncology (RANO) Working Group has published new recommendations in high-grade gliomas and is working on recommendations for other nervous system tumors. This article reviews current response criteria for high-grade glioma, low-grade glioma, brain metastasis, meningioma, and schwannoma.

  16. Optimizing multi-dimensional high throughput screening using zebrafish.

    PubMed

    Truong, Lisa; Bugel, Sean M; Chlebowski, Anna; Usenko, Crystal Y; Simonich, Michael T; Simonich, Staci L Massey; Tanguay, Robert L

    2016-10-01

    The use of zebrafish for high throughput screening (HTS) for chemical bioactivity assessments is becoming routine in the fields of drug discovery and toxicology. Here we report current recommendations from our experiences in zebrafish HTS. We compared the effects of different high throughput chemical delivery methods on nominal water concentration, chemical sorption to multi-well polystyrene plates, transcription responses, and resulting whole animal responses. We demonstrate that digital dispensing consistently yields higher data quality and reproducibility compared to standard plastic tip-based liquid handling. Additionally, we illustrate the challenges in using this sensitive model for chemical assessment when test chemicals have trace impurities. Adaptation of these better practices for zebrafish HTS should increase reproducibility across laboratories. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Protein precipitation of diluted samples in SDS-containing buffer with acetone leads to higher protein recovery and reproducibility in comparison with TCA/acetone approach.

    PubMed

    Santa, Cátia; Anjo, Sandra I; Manadas, Bruno

    2016-07-01

    Proteomic approaches are extremely valuable in many fields of research, where mass spectrometry methods have gained an increasing interest, especially because of the ability to perform quantitative analysis. Nonetheless, sample preparation prior to mass spectrometry analysis is of the utmost importance. In this work, two protein precipitation approaches, widely used for cleaning and concentrating protein samples, were tested and compared in very diluted samples solubilized in a strong buffer (containing SDS). The amount of protein recovered after acetone and TCA/acetone precipitation was assessed, as well as the protein identification and relative quantification by SWATH-MS yields were compared with the results from the same sample without precipitation. From this study, it was possible to conclude that in the case of diluted samples in denaturing buffers, the use of cold acetone as precipitation protocol is more favourable than the use of TCA/acetone in terms of reproducibility in protein recovery and number of identified and quantified proteins. Furthermore, the reproducibility in relative quantification of the proteins is even higher in samples precipitated with acetone compared with the original sample. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Effects of Gradient Coil Noise and Gradient Coil Replacement on the Reproducibility of Resting State Networks.

    PubMed

    Bagarinao, Epifanio; Tsuzuki, Erina; Yoshida, Yukina; Ozawa, Yohei; Kuzuya, Maki; Otani, Takashi; Koyama, Shuji; Isoda, Haruo; Watanabe, Hirohisa; Maesawa, Satoshi; Naganawa, Shinji; Sobue, Gen

    2018-01-01

    The stability of the MRI scanner throughout a given study is critical in minimizing hardware-induced variability in the acquired imaging data set. However, MRI scanners do malfunction at times, which could generate image artifacts and would require the replacement of a major component such as its gradient coil. In this article, we examined the effect of low intensity, randomly occurring hardware-related noise due to a faulty gradient coil on brain morphometric measures derived from T1-weighted images and resting state networks (RSNs) constructed from resting state functional MRI. We also introduced a method to detect and minimize the effect of the noise associated with a faulty gradient coil. Finally, we assessed the reproducibility of these morphometric measures and RSNs before and after gradient coil replacement. Our results showed that gradient coil noise, even at relatively low intensities, could introduce a large number of voxels exhibiting spurious significant connectivity changes in several RSNs. However, censoring the affected volumes during the analysis could minimize, if not completely eliminate, these spurious connectivity changes and could lead to reproducible RSNs even after gradient coil replacement.

  19. Effects of Gradient Coil Noise and Gradient Coil Replacement on the Reproducibility of Resting State Networks

    PubMed Central

    Bagarinao, Epifanio; Tsuzuki, Erina; Yoshida, Yukina; Ozawa, Yohei; Kuzuya, Maki; Otani, Takashi; Koyama, Shuji; Isoda, Haruo; Watanabe, Hirohisa; Maesawa, Satoshi; Naganawa, Shinji; Sobue, Gen

    2018-01-01

    The stability of the MRI scanner throughout a given study is critical in minimizing hardware-induced variability in the acquired imaging data set. However, MRI scanners do malfunction at times, which could generate image artifacts and would require the replacement of a major component such as its gradient coil. In this article, we examined the effect of low intensity, randomly occurring hardware-related noise due to a faulty gradient coil on brain morphometric measures derived from T1-weighted images and resting state networks (RSNs) constructed from resting state functional MRI. We also introduced a method to detect and minimize the effect of the noise associated with a faulty gradient coil. Finally, we assessed the reproducibility of these morphometric measures and RSNs before and after gradient coil replacement. Our results showed that gradient coil noise, even at relatively low intensities, could introduce a large number of voxels exhibiting spurious significant connectivity changes in several RSNs. However, censoring the affected volumes during the analysis could minimize, if not completely eliminate, these spurious connectivity changes and could lead to reproducible RSNs even after gradient coil replacement. PMID:29725294

  20. Reproducibility of a four-point clinical severity score for glabellar frown lines.

    PubMed

    Honeck, P; Weiss, C; Sterry, W; Rzany, B

    2003-08-01

    Focal injections of botulinum toxin A are used successfully for the treatment of hyperkinetic facial wrinkles. Efficacy can be measured by several methods. However, so far none has been investigated for its reproducibility. Objectives To investigate the reproducibility of a clinical 0-3 score for glabellar frown lines. In the first part of the study, a standardized photographic documentation of glabellar frown lines was produced. Based on the results of this phase, a consensus atlas of glabellar frown lines was developed and participants were trained using this atlas. In the main study, 50 standardized photographs were shown on two consecutive days to 28 dermatologists. The reproducibility of the score was investigated by conventional kappa statistics. In the main study, we found an unweighted kappa according to Fleiss of 0.62 for interobserver reproducibility. Intraobserver reproducibility showed an unweighted kappa according to Cohen of between 0.57 and 0.91 for each observer, and a weighted kappa according to Cicchetti and Allison of between 0.68 and 0.94. The clinical 0-3 score for glabellar frown lines shows a good inter- and intraobserver reproducibility.

Top