Sample records for study comparing conventional

  1. Improving the quality of randomized controlled trials in Chinese herbal medicine, part II: control group design.

    PubMed

    Bian, Zhao-Xiang; Moher, David; Dagenais, Simon; Li, You-Ping; Liu, Liang; Wu, Tai-Xiang; Miao, Jiang-Xia

    2006-03-01

    To discuss the types of control groups in randomized controlled trials (RCTs) of Chinese herbal medicine (CHM), and to provide suggestions for improving the design of control group in future clinical studies in this therapeutic area. A search of the Cochrane Library was conducted in July 2005 to identify RCTs of CHM, and 66 RCTs with CHM for type 2 diabetes mellitus were obtained as the basis for further analysis. Of 66 RCTs with CHM for type 2 diabetes mellitus, 61 (92.4%) trials had both a treatment group and a control group. Twenty-seven (40.9%) RCTs compared CHM plus conventional drug vs conventional drug, 24 (36.4%) compared CHM vs conventional drug, 5 (7.6%) compared CHM vs placebo, 3 (4.5%) compared CHM plus conventional drug vs conventional drug plus placebo, 3 (4.5%) compared CHM plus conventional drug vs other CHM, 1 (1.5%) compared CHM vs no treatment, 1 (1.5%) compared CHM plus placebo vs conventional drug plus placebo, 1 (1.5%) compared CHM vs CHM plus conventional drug vs conventional drug vs placebo, and 1 (1.5%) compared CHM vs conventional drug vs CHM plus conventional drug. A variety of control groups were used in RCTs of CHM for type 2 diabetes mellitus, including placebo, active, and no treatment control groups. Justification for selecting particular types of control groups were not provided in the trials reviewed in this study. Different control groups may be appropriate according to the study objectives, and several factors should be considered prior to selecting control groups in future RCTs of CHM. (1) Investigators of CHM who design clinical trials should understand the rationale for selecting different types of control groups; (2) Control groups for RCTs should be selected according to study objectives; (3) Active control groups should select interventions for comparisons that have the strongest evidence of efficacy and prescribe them as recommended; (4) Placebo control groups should select a placebo that mimics the physical characteristics of test intervention as closely as possible and is completely inert; (5) No treatment control groups should only be used when withholding treatment is ethical and objectives outcomes will not be subject to bias due to absent blinding; (6) Crossover control groups may be appropriate in chronic and stable conditions.

  2. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    PubMed Central

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). Results In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conclusions Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words:Systematic review, self ligation, torque expression, conventional ligation. PMID:28149476

  3. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

    PubMed

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words: Systematic review, self ligation, torque expression, conventional ligation.

  4. Comparison of marginal accuracy of castings fabricated by conventional casting technique and accelerated casting technique: an in vitro study.

    PubMed

    Reddy, S Srikanth; Revathi, Kakkirala; Reddy, S Kranthikumar

    2013-01-01

    Conventional casting technique is time consuming when compared to accelerated casting technique. In this study, marginal accuracy of castings fabricated using accelerated and conventional casting technique was compared. 20 wax patterns were fabricated and the marginal discrepancy between the die and patterns were measured using Optical stereomicroscope. Ten wax patterns were used for Conventional casting and the rest for Accelerated casting. A Nickel-Chromium alloy was used for the casting. The castings were measured for marginal discrepancies and compared. Castings fabricated using Conventional casting technique showed less vertical marginal discrepancy than the castings fabricated by Accelerated casting technique. The values were statistically highly significant. Conventional casting technique produced better marginal accuracy when compared to Accelerated casting. The vertical marginal discrepancy produced by the Accelerated casting technique was well within the maximum clinical tolerance limits. Accelerated casting technique can be used to save lab time to fabricate clinical crowns with acceptable vertical marginal discrepancy.

  5. Quality characteristics of battered and fried chicken: comparison of pressure frying and conventional frying.

    PubMed

    Das, Rashmi; Pawar, Deepthi P; Modi, Vinod Kumar

    2013-04-01

    The marinated and battered chicken leg meat and breast meat were pressure fried and their physico-chemical qualities were compared to the conventional fried product (open pan deep fat frying). Shrinkage due to frying process was significantly lesser in case of pressure fried leg meat (PLM) and breast meat (PBM) as compared to products prepared by conventional frying leg meat (CLM) and breast meat (CBM). Also, juiciness of pressure fried chicken products was superior (p ≤ 0.05) than fried products obtained by the conventional method. PLM and PBM had lower fat content (p ≤ 0.05) compared to conventionally fried CLM and CBM. Lipid oxidation was higher (p ≤ 0.05) in conventional frying as compared to pressure frying. Irrespective of the type of chicken meat, conventionally fried meat required higher shear force as compared to pressure fried products. Salmonella, Staphylococcus aureus, Shigella and E. coli were not detected. The study indicates the usefulness and superiority of pressure frying in comparison to conventional deep fat frying.

  6. Comparative Life Cycle Assessment between Warm SMA and Conventional SMA

    DOT National Transportation Integrated Search

    2011-09-01

    This report presents the comparative life cycle assessment (LCA) between warm stone mastic asphalt (SMA) and conventional : SMA. Specifically, the study evaluated and compared the life cycle environmental and economic performances of two mixtures: a ...

  7. A comparative study of conventionally sintered and microwave sintered nickel zinc ferrite

    NASA Astrophysics Data System (ADS)

    Rani, Rekha; Juneja, J. K.; Raina, K. K.; Kotnala, R. K.; Prakash, Chandra

    2014-04-01

    For the present work, nickel zinc ferrite having compositional formula Ni0.8Zn0.2Fe2O4 was synthesized by conventional solid state method and sintered in conventional and microwave furnaces. Pellets were sintered with very short soaking time of 10 min at 1150 °C in microwave furnace whereas 4 hrs of soaking time was selected for conventional sintering at 1200 °C. Phase formation was confirmed by X-ray diffraction analysis technique. Scanning electron micrographs were taken for microstructural study. Dielectric properties were studied as a function of temperature. To study magnetic behavior, M-H hysteresis loops were recorded for both samples. It is observed that microwave sintered sample could obtain comparable properties to the conventionally sintered one in lesser soaking time at lower sintering temperature.

  8. Comparative study of the results from conventional cervico-vaginal oncotic cytology and liquid-based cytology.

    PubMed

    Stabile, Sueli Aparecida Batista; Evangelista, Dilson Henrique Ramos; Talamonte, Valdely Helena; Lippi, Umberto Gazi; Lopes, Reginaldo Guedes Coelho

    2012-01-01

    To compare two oncotic cervical cytology techniques, the conventional and the liquid-based cytology, in low risk patients for uterine cervical cancer. Comparative prospective study with 100 patients who came to their annual gynecological exam, and were submitted simultaneously to both techniques. We used the McNemar test, with a significance level of p < 0.05 to compare the results obtained related to adequacy of the smear quality, descriptive diagnosis prevalence, guided biopsy confirmation and histology. Adequacy of the smear was similar for both methods. The quality with squamocolumnar junction in 93% of conventional cytology and in 84% of the liquid-based cytology had statistical significance. As for the diagnosis of atypical cells they were detected in 3% of conventional cytology and in 10% of liquid-based cytology (p = 0.06). Atypical squamous cells of undetermined significance were the most prevalent abnormality. The liquid-based cytology performance was better when compared with colposcopy (guided biopsy), presenting sensitivity of 66.7% and specificity of 100%. There was no cytological and histological concordance for the conventional cytology. Liquid-based cytology had a better performance to diagnose atypical cells and the cytohistological concordance was higher than in the conventional cytology.

  9. Outcome reporting following navigated high tibial osteotomy of the knee: a systematic review.

    PubMed

    Yan, James; Musahl, Volker; Kay, Jeffrey; Khan, Moin; Simunovic, Nicole; Ayeni, Olufemi R

    2016-11-01

    This systematic review evaluates radiographic and clinical outcome reporting following navigated high tibial osteotomy (HTO). Conventional HTO was used as a control to compare outcomes and furthermore investigate the quality of evidence in studies reporting outcomes for navigated HTO. It was hypothesized that navigated HTO will show superior clinical and radiographic outcomes compared to conventional HTO. Two independent reviewers searched PubMed, Ovid (MEDLINE), EMBASE, and Cochrane databases for studies reporting outcomes following navigated HTO. Titles, abstracts, and full-text were screened in duplicate using an a priori inclusion and exclusion criteria. Descriptive statistics were calculated using Minitab ® statistical software. Methodological Index for Nonrandomized Studies (MINORS) and Cochrane Risk of Bias Scores were used to evaluate methodological quality. Thirty-four studies which involved 2216 HTOs were analysed in this review, 1608 (72.6 %) navigated HTOs and 608 (27.4 %) conventional HTOs. The majority of studies were of level IV evidence (16). Clinical outcomes were reported in knee and function scores or range of motion comparisons. Postoperative clinical and functional scores were improved by navigated HTO although it is not demonstrated if there is significant improvement compared to conventional HTO. Most common clinical outcome score reported was Lysholm scores (6) which report postoperative scores of 87.8 (standard deviation 5.9) and 88.8 (standard deviation 5.9) for conventional and navigation-assisted HTO, respectively. Radiographic outcomes reported commonly were weight-bearing mechanical axis, coronal plane angle, and posterior tibial slope angle in the sagittal plane. Studies have shown HTO gives significant correction of mechanical alignment and navigated HTO produces significantly less change in posterior tibial slope postoperatively compared to conventional. The mean MINORS for the 17 non-comparative studies was 9/16, and 15/24 for the 14 non-randomized comparative studies. Navigation HTO results in improved mechanical axis alignment and demonstrates significantly better control over the tibial slope angle change postoperatively compared to conventional methods; however, these improvements have not yet been reflected in clinical outcome scores. Overall the studies report HTO does create significantly improved knee scores and functions compared to patients' preoperative ratings regardless of technique. Future studies on HTO outcomes need to focus on consistency of outcome reporting. IV.

  10. Continuous prophylaxis with recombinant factor IX Fc fusion protein and conventional recombinant factor IX products: comparisons of efficacy and weekly factor consumption.

    PubMed

    Iorio, Alfonso; Krishnan, Sangeeta; Myrén, Karl-Johan; Lethagen, Stefan; McCormick, Nora; Yermakov, Sander; Karner, Paul

    2017-04-01

    Continuous prophylaxis for patients with hemophilia B requires frequent injections that are burdensome and that may lead to suboptimal adherence and outcomes. Hence, therapies requiring less-frequent injections are needed. In the absence of head-to-head comparisons, this study compared the first extended-half-life-recombinant factor IX (rFIX) product-recombinant factor IX Fc fusion protein (rFIXFc)-with conventional rFIX products based on annualized bleed rates (ABRs) and factor consumption reported in studies of continuous prophylaxis. This study compared ABRs and weekly factor consumption rates in clinical studies of continuous prophylaxis treatment with rFIXFc and conventional rFIX products (identified by systematic literature review) in previously-treated adolescents and adults with moderate-to-severe hemophilia B. Meta-analysis was used to pool ABRs reported for conventional rFIX products for comparison. Comparisons of weekly factor consumption were based on the mean, reported or estimated from the mean dose per injection. Five conventional rFIX studies (injections 1 to >3 times/week) met the criteria for comparison with once-weekly rFIXFc reported by the B-LONG study. The pooled mean ABR for conventional rFIX was slightly higher than but comparable to rFIXFc (difference=0.71; p = 0.210). Weekly factor consumption was significantly lower with rFIXFc than in conventional rFIX studies (difference in means = 42.8-74.5 IU/kg/week [93-161%], p < 0.001). Comparisons of clinical study results suggest weekly injections with rFIXFc result in similar bleeding rates and significantly lower weekly factor consumption compared with more-frequently-injected conventional rFIX products. The real-world effectiveness of rFIXFc may be higher based on results from a model of the impact of simulated differences in adherence.

  11. The Use of Hyper-Reference and Conventional Dictionaries.

    ERIC Educational Resources Information Center

    Aust, Ronald; And Others

    1993-01-01

    Describes a study of 80 undergraduate foreign language learners that compared the use of a hyper-reference source incorporating an electronic dictionary and a conventional paper dictionary. Measures of consultation frequency, study time, efficiency, and comprehension are examined; bilingual and monolingual dictionary use is compared; and further…

  12. High resolution vs conventional esophageal manometry in the assessment of esophageal motor disorders in patients with non-cardiac chest pain.

    PubMed

    Akinsiku, O; Yamasaki, T; Brunner, S; Ganocy, S; Fass, R

    2018-06-01

    High-resolution esophageal manometry (HREM) has become a leading tool in the assessment of esophageal motor disorders, replacing conventional manometry. However, there is limited data about the contribution of HREM as compared with conventional manometry to the assessment of esophageal motor disorders in patients with non-cardiac chest pain (NCCP). The aim of the study was to compare the distribution of esophageal motor disorders in patients with NCCP using HREM as compared with conventional manometry and to determine if HREM improved diagnosis of these disorders. In this study, we included 300 consecutive patients with NCCP who underwent either HREM or conventional manometry over a period of 10 years. A total of 150 patients had conventional manometry and the other 150 patients HREM. The Chicago 3.0 classification and the Castell and Spechler classification were used to determine the esophageal motor disorder of NCCP patients undergoing HREM and conventional manometry, respectively. In both HREM and the conventional manometry groups, normal esophageal motility was the most frequent finding (47% and 36%; respectively, P = .054). Hypotensive lower esophageal sphincter was the most common motility disorder identified by conventional manometry (27.3%), while ineffective esophageal motility was the most common esophageal motor disorder identified by HREM (25.3%). There is a discrepancy in the type of esophageal motor disorders identified by HREM as compared with conventional manometry in NCCP patients. Hypotensive motility disorders are the most commonly diagnosed by both manometric techniques. © 2017 John Wiley & Sons Ltd.

  13. A comparative study of the incidence of Schneiderian membrane perforations during maxillary sinus augmentation with a sonic oscillating handpiece versus a conventional turbine handpiece.

    PubMed

    Geminiani, Alessandro; Weitz, Daniel S; Ercoli, Carlo; Feng, Changyong; Caton, Jack G; Papadimitriou, Dimitrios E V

    2015-04-01

    Sonic instruments may reduce perforation rates of the schneiderian membrane during lateral window sinus augmentation procedures. This study compares the incidence of membrane perforations using a sonic handpiece with an oscillating diamond insert versus a turbine handpiece with a conventional rotary diamond stone during lateral window sinus augmentation procedures. A retrospective chart analysis identified all lateral window sinus augmentation procedures done during a defined period. Among these procedures, those performed with a sonic handpiece and an oscillating diamond insert (experimental) and those performed with a conventional turbine and rotary diamond stone (conventional) were selected for this study. Reported occurrences of sinus membrane perforations during preparation of the osteotomy and elevation of the sinus membrane, as well as postoperative complications, were recorded and compared between treatment groups. Ninety-three consecutive patients were identified for a total of 130 sinus augmentation procedures (51 conventional, 79 experimental). Schneiderian membrane perforations were noted during preparation of the lateral window osteotomy in 27.5% of the sinuses in the conventional group and 12.7% of sinuses in the experimental group. During membrane elevation, perforations were noted in 43.1% of the sinuses in the conventional group and 25.3% of sinuses in the experimental group. Both differences in perforation rates were statistically significant (p < .05). There was no statistically significant difference in postoperative complications. In this study, the use of a sonic instrument to prepare the lateral window osteotomy during sinus elevation procedures resulted in a reduced perforation rate of the Schneiderian membrane compared with the conventional turbine instrument. © 2013 Wiley Periodicals, Inc.

  14. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

    PubMed

    Ishihara, Masaru; Onoguchi, Masahisa; Taniguchi, Yasuyo; Shibutani, Takayuki

    2017-12-01

    The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.

  15. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model.

    PubMed

    Park, Hong Suk; Choo, In Wook; Seo, Soowon; Hyun, Dongho; Lim, Sooyoun; Kim, Jae J; Hong, Saet-Byul; Min, Byung-Hoon; Do, Young Soo; Choo, Sung Wook; Shin, Sung Wook; Park, Kwang Bo; Cho, Sung Ki

    2015-01-01

    Migration of stents is one of the most common adverse events in covered stent placement in GI tract obstruction. To compare physical property and migration rates in a canine colon obstruction model among a novel stent and conventional stents. Comparative physical test and animal study. Medical device testing laboratory and animal laboratory. Mongrel dogs (N=26). Surgical colon obstruction followed by placement of a novel (n=13) or conventional (n=13) stent. Physical properties, migration, and adverse events. The novel stent showed better flexibility, as in a physical test of longitudinal compressibility and axial force, than did conventional stents, and it withstood the fatigue test for 10 days. In terms of radial force and tensile strength, the novel stent showed the same or better results than conventional stents. In a canine colon obstruction model, the migration rate of a novel stent was significantly lower than that of a conventional stent (2/13, 15.4% vs 8/13, 61.5%; P=.008). Animal study of limited size. The novel, ring-connected stent is more flexible and more resistant to migration than the conventional stents. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  16. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    PubMed

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, p<0.001). The five- and 10-year survival rates were 97.1% and 89.6%, respectively. No difference was detected in nine-year survival rates (p=0.369) between the two groups, although the clinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Comparative Study of Elemental Nutrients in Organic and Conventional Vegetables Using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Bhatt, Chet R; Alfarraj, Bader; Ghany, Charles T; Yueh, Fang Y; Singh, Jagdish P

    2017-04-01

    In this study, the laser-induced breakdown spectroscopy (LIBS) technique was used to identify and compare the presence of major nutrient elements in organic and conventional vegetables. Different parts of cauliflowers and broccolis were used as working samples. Laser-induced breakdown spectra from these samples were acquired at optimum values of laser energy, gate delay, and gate width. Both univariate and multivariate analyses were performed for the comparison of these organic and conventional vegetable flowers. Principal component analysis (PCA) was taken into account for multivariate analysis while for univariate analysis, the intensity of selected atomic lines of different elements and their intensity ratio with some reference lines of organic cauliflower and broccoli samples were compared with those of conventional ones. In addition, different parts of the cauliflower and broccoli were compared in terms of intensity and intensity ratio of elemental lines.

  18. A comparison of graft and patient outcomes following kidney transplantation in extended hour and conventional haemodialysis patients.

    PubMed

    See, Emily J; Hawley, Carmel M; Cho, Yeoungjee; Toussaint, Nigel D; Agar, John Wm; Pascoe, Elaine M; Lim, Wai H; Francis, Ross S; Collins, Michael G; Johnson, David W

    2018-01-08

    Differences in early graft function between kidney transplant recipients previously managed with either haemodialysis (HD) or peritoneal dialysis are well described. However, only two single-centre studies have compared graft and patient outcomes between extended hour and conventional HD patients, with conflicting results. This study compared the outcomes of all extended hour (≥24 hours/week) and conventional HD patients transplanted in Australia and New Zealand between 2000 and 2014. The primary outcome was delayed graft function (DGF), defined in an ordinal manner as either a spontaneous fall in serum creatinine of less than 10% within 24 hours, or the need for dialysis within 72 hours following transplantation. Secondary outcomes included the requirement for dialysis within 72 hours post-transplant, acute rejection, estimated glomerular filtration rate at 12 months, death-censored graft failure, all-cause and cardiovascular mortality, and a composite of graft failure and mortality. A total of 4,935 HD patients (378 extended hour HD, 4,557 conventional HD) received a kidney transplant during the study period. Extended hour HD was associated with an increased likelihood of DGF compared with conventional HD (adjusted proportional odds ratio 1.33; 95% confidence interval 1.06-1.67). There was no significant difference between extended hour and conventional HD in terms of any of the secondary outcomes. Compared to conventional HD, extended hour HD was associated with DGF, although long-term graft and patient outcomes were not different. This article is protected by copyright. All rights reserved.

  19. Incidence of Tardive Dyskinesia with Atypical and Conventional Antipsychotic Medications: Prospective Cohort Study

    PubMed Central

    Woods, Scott W.; Morgenstern, Hal; Saksa, John R.; Walsh, Barbara C.; Sullivan, Michelle C.; Money, Roy; Hawkins, Keith A.; Gueorguieva, Ralitza V.; Glazer, William M.

    2011-01-01

    Objective Most previous studies of the incidence of tardive dyskinesia with atypical compared to conventional antipsychotics have not had tardive dyskinesia as their primary focus. The current study aimed to compare the incidence of tardive dyskinesia with atypical vs. conventional antipsychotics using methods similar to those from a previous prospective cohort study at our site in the 1980s. Method 352 initially tardive dyskinesia-free psychiatric outpatients were examined for a new diagnosis of tardive dyskinesia every 6 months for up to 4 years at a community mental health center. At baseline, subjects were receiving conventional antipsychotics only (23%), atypicals only (64%), or both (14%). Only 26 subjects had never received conventional antipsychotics. Results Compared with subjects treated with conventional antipsychotics alone since the previous visit, the adjusted tardive dyskinesia incidence rate-ratio for subjects treated with atypical antipsychotics alone was 0.68 (95% confidence interval 0.29 to 1.64). The incidence and prevalence of tardive dyskinesia was similar to previous findings at this site in the 1980s. Conclusion The incidence of tardive dyskinesia with recent exposure to atypical antipsychotics alone was more similar to that for conventional antipsychotics than in most previous studies. Despite high penetration of atypical antipsychotics into clinical practice, the incidence and prevalence of tardive dyskinesia appeared relatively unchanged since the 1980s. Clinicians should continue to monitor for tardive dyskinesia, and researchers should continue to pursue efforts to treat or prevent it. PMID:20156410

  20. Gastrointestinal toxicity among patients taking selective COX-2 inhibitors or conventional NSAIDs, alone or combined with proton pump inhibitors: a case-control study.

    PubMed

    Bakhriansyah, Mohammad; Souverein, Patrick C; de Boer, Anthonius; Klungel, Olaf H

    2017-10-01

    To assess the risk of gastrointestinal perforation, ulcers, or bleeding (PUB) associated with the use of conventional nonsteroidal anti-inflammatory drugs (NSAIDs) with proton pump inhibitors (PPIs) and selective COX-2 inhibitors, with or without PPIs compared with conventional NSAIDs. A case-control study was performed within conventional NSAIDs and/or selective COX-2 inhibitors users identified from the Dutch PHARMO Record Linkage System in the period 1998-2012. Cases were patients aged ≥18 years with a first hospital admission for PUB. For each case, up to four controls were matched for age and sex at the date a case was hospitalized (index date). Logistic regression analysis was used to calculate odds ratios (ORs). At the index date, 2634 cases and 5074 controls were current users of conventional NSAIDs or selective COX-2 inhibitors. Compared with conventional NSAIDs, selective COX-2 inhibitors with PPIs had the lowest risk of PUB (adjusted OR 0.51, 95% confidence interval [CI]: 0.35-0.73) followed by selective COX-2 inhibitors (adjusted OR 0.66, 95%CI: 0.48-0.89) and conventional NSAIDs with PPIs (adjusted OR 0.79, 95%CI: 0.68-0.92). Compared with conventional NSAIDs, the risk of PUB was lower for those aged ≥75 years taking conventional NSAIDs with PPIs compared with younger patients (adjusted interaction OR 0.79, 95%CI: 0.64-0.99). However, those aged ≥75 years taking selective COX-2 inhibitors, the risk was higher compared with younger patients (adjusted interaction OR 1.22, 95%CI: 1.01-1.47). Selective COX-2 inhibitors with PPIs, selective COX-2 inhibitors, and conventional NSAIDs with PPIs were associated with lower risks of PUB compared with conventional NSAIDs. These effects were modified by age. © 2017 The Authors. Pharmacoepidemiology & Drug Safety Published by John Wiley & Sons Ltd. © 2017 The Authors. Pharmacoepidemiology & Drug Safety Published by John Wiley & Sons Ltd.

  1. Measuring the environmental effects of organic farming: A meta-analysis of structural variables in empirical research.

    PubMed

    Lee, Ki Song; Choe, Young Chan; Park, Sung Hee

    2015-10-01

    This study examined the structural variables affecting the environmental effects of organic farming compared to those of conventional farming. A meta-analysis based on 107 studies and 360 observations published from 1977 to 2012 compared energy efficiency (EE) and greenhouse gas emissions (GHGE) for organic and conventional farming. The meta-analysis systematically analyzed the results of earlier comparative studies and used logistic regression to identify the structural variables that contributed to differences in the effects of organic and conventional farming on the environment. The statistical evidence identified characteristics that differentiated the environmental effects of organic and conventional farming, which is controversial. The results indicated that data sources, sample size and product type significantly affected EE, whereas product type, cropping pattern and measurement unit significantly affected the GHGE of organic farming compared to conventional farming. Superior effects of organic farming on the environment were more likely to appear for larger samples, primary data rather than secondary data, monocropping rather than multicropping, and crops other than fruits and vegetables. The environmental effects of organic farming were not affected by the study period, geographic location, farm size, cropping pattern, or measurement method. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. [Comparative Study of Patient Identifications for Conventional and Portable Chest Radiographs Utilizing ROC Analysis].

    PubMed

    Kawashima, Hiroki; Hayashi, Norio; Ohno, Naoki; Matsuura, Yukihiro; Sanada, Shigeru

    2015-08-01

    To evaluate the patient identification ability of radiographers, previous and current chest radiographs were assessed with observer study utilizing a receiver operating characteristics (ROCs) analysis. This study included portable and conventional chest radiographs from 43 same and 43 different patients. The dataset used in this study was divided into the three following groups: (1) a pair of portable radiographs, (2) a pair of conventional radiographs, and (3) a combination of each type of radiograph. Seven observers participated in this ROC study, which aimed to identify same or different patients, using these datasets. ROC analysis was conducted to calculate the average area under ROC curve obtained by each observer (AUCave), and a statistical test was performed using the multi-reader multi-case method. Comparable results were obtained with pairs of portable (AUCave: 0.949) and conventional radiographs (AUCave: 0.951). In a comparison between the same modality, there were no significant differences. In contrast, the ability to identify patients by comparing a portable and conventional radiograph (AUCave: 0.873) was lower than with the matching datasets (p=0.002 and p=0.004, respectively). In conclusion, the use of different imaging modalities reduces radiographers' ability to identify their patients.

  3. A Comparative Evaluation of the Effect of Double Casting Technique Using Functionally Generated Path and Conventional Single Casting with Respect to Functional Articulation, Patient Satisfaction and Chair Side Time, in Single Unit Molar Teeth: An In Vivo Study.

    PubMed

    Memon, Sarfaraz

    2014-12-01

    A stable centric occlusal position that shows no evidence of occlusal disease should not be altered. Confirmative restorative dentistry deals with making restorations that are in harmony with existing jaw relations. Conventional techniques for construction have been unsuccessful in producing a prosthesis that can be inserted without minor intraoral occlusal adjustment. This study was conducted to evaluate the benefits of the double casting technique with FGP over the conventional casting technique. Ten patients with root canal treated maxillary molar were selected for the fabrication of metal crown. Two techniques, one involving the conventional fabrication and other using functionally generated path with double casting were used to fabricate the prosthesis. A comparison based on various parameters which was done between the two techniques. The change in the height of castings for the double casting group was less compared to the conventional group and was highly statistically significant (P < 0.001). The time taken for occlusal correction was significantly lower in double casting group than the conventional group (P < 0.001). The patient satisfaction (before occlusal correction) indicated better satisfaction for double casting group compared to conventional (P < 0.01). The functionally generated path with double casting technique resulted in castings which had better dimensional accuracy, less occlusal correction and better patient satisfaction compared to the conventional castings.

  4. Comparing organic versus conventional soil management on soil respiration.

    PubMed

    Mátyás, Bence; Chiluisa Andrade, Maritza Elizabeth; Yandun Chida, Nora Carmen; Taipe Velasco, Carina Maribel; Gavilanes Morales, Denisse Estefania; Miño Montero, Gisella Nicole; Ramirez Cando, Lenin Javier; Lizano Acevedo, Ronnie Xavier

    2018-01-01

    Soil management has great potential to affect soil respiration. In this study, we investigated the effects of organic versus conventional soil management on soil respiration.  We measured the main soil physical-chemical properties from conventional and organic managed soil in Ecuador. Soil respiration was determined using alkaline absorption according to Witkamp.  Soil properties such as organic matter, nitrogen, and humidity, were comparable between conventional and organic soils in the present study, and in a further analysis there was no statically significant correlation with soil respiration. Therefore, even though organic farmers tend to apply more organic material to their fields, but this did not result in a significantly higher CO2 production in their soils in the present study.

  5. Comparing organic versus conventional soil management on soil respiration

    PubMed Central

    Mátyás, Bence; Chiluisa Andrade, Maritza Elizabeth; Yandun Chida, Nora Carmen; Taipe Velasco, Carina Maribel; Gavilanes Morales, Denisse Estefania; Miño Montero, Gisella Nicole; Ramirez Cando, Lenin Javier; Lizano Acevedo, Ronnie Xavier

    2018-01-01

    Soil management has great potential to affect soil respiration. In this study, we investigated the effects of organic versus conventional soil management on soil respiration.  We measured the main soil physical-chemical properties from conventional and organic managed soil in Ecuador. Soil respiration was determined using alkaline absorption according to Witkamp.  Soil properties such as organic matter, nitrogen, and humidity, were comparable between conventional and organic soils in the present study, and in a further analysis there was no statically significant correlation with soil respiration. Therefore, even though organic farmers tend to apply more organic material to their fields, but this did not result in a significantly higher CO2 production in their soils in the present study. PMID:29623193

  6. Report on the study of the tax and rate treatment of renewable energy projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadley, S.W.; Hill, L.J.; Perlack, R.D.

    1993-12-01

    This study was conducted in response to the requirements of Section 1205 of the Energy Policy Act of 1992 (EPACT), which states: The Secretary (of Energy), in conjunction with State regulatory commissions, shall undertake a study to determine if conventional taxation and ratemaking procedures result in economic barriers to or incentives for renewable energy power plants compared to conventional power plants. The purpose of the study, therefore, is not to compare the cost-effectiveness of different types of renewable and conventional electric generating plants. Rather, it is to determine the relative impact of conventional ratemaking and taxation procedures on the selectionmore » of renewable power plants compared to conventional ones. To make this determination, we quantify the technical and financial parameters of renewable and conventional electric generating technologies, and hold them fixed throughout the study. Then, we vary taxation and ratemaking procedures to determine their effects on the financial criteria that investor-owned electric utilities (IOUs) and nonutility electricity generators (NUGs) use to make technology-adoption decisions. In the planning process of a typical utility, the opposite is usually the case. That is, utilities typically hold ratemaking and taxation procedures constant and look for the least-cost mix of resources, varying the values of engineering and financial parameters of generating plants in the process.« less

  7. No effect of the farming system (organic/conventional) on the bioavailability of apple (Malus domestica Bork., cultivar Golden Delicious) polyphenols in healthy men: a comparative study.

    PubMed

    Stracke, Berenike A; Rüfer, Corinna E; Bub, Achim; Seifert, Stephanie; Weibel, Franco P; Kunz, Clemens; Watzl, Bernhard

    2010-08-01

    The organic food sales have been increasing during the recent years. It has been hypothesised that organically grown fruits are healthier based on their higher content of phytochemicals. However, data on the bioavailability of phytochemicals from organically or conventionally produced plant foods are scarce. Two human intervention studies were performed to compare the bioavailability of polyphenols in healthy men after ingestion of apples from different farming systems. The administered apples were grown organically and conventionally under defined conditions and characterised regarding their polyphenol content and antioxidant capacity. No significant differences in the polyphenol content and the antioxidant capacity from the organic and conventional farming system were observed. In the short-term intervention study, six men consumed either organically or conventionally produced apples in a randomized cross-over study. After intake of 1 kg apples, phloretin (C (max) 13 + or - 5 nmol/l, t (max) 1.7 + or - 1.2 h) and coumaric acid (C (max )35 + or - 12 nmol/l, t (max) 3.0 + or - 0.8 h) plasma concentrations increased significantly (P < 0.0001) in both intervention groups, without differences between the two farming systems. In the long-term intervention study, 43 healthy volunteers consumed organically or conventionally produced apples (500 g/day; 4 weeks) or no apples in a double-blind, randomized intervention study. In this study, 24 h after the last dosing regime, the apple intake did not result in increasing polyphenol concentrations in plasma and urine compared to the control group suggesting no accumulation of apple polyphenols or degradation products in humans. Our study suggests that the two farming systems (organic/conventional) do not result in differences in the bioavailability of apple polyphenols.

  8. Effectiveness of additional supervised exercises compared with conventional treatment alone in patients with acute lateral ankle sprains: systematic review

    PubMed Central

    van Ochten, John; Luijsterburg, Pim A J; van Middelkoop, Marienke; Koes, Bart W; Bierma-Zeinstra, Sita M A

    2010-01-01

    Objective To summarise the effectiveness of adding supervised exercises to conventional treatment compared with conventional treatment alone in patients with acute lateral ankle sprains. Design Systematic review. Data sources Medline, Embase, Cochrane Central Register of Controlled Trials, Cinahl, and reference screening. Study selection Included studies were randomised controlled trials, quasi-randomised controlled trials, or clinical trials. Patients were adolescents or adults with an acute lateral ankle sprain. The treatment options were conventional treatment alone or conventional treatment combined with supervised exercises. Two reviewers independently assessed the risk of bias, and one reviewer extracted data. Because of clinical heterogeneity we analysed the data using a best evidence synthesis. Follow-up was classified as short term (up to two weeks), intermediate (two weeks to three months), and long term (more than three months). Results 11 studies were included. There was limited to moderate evidence to suggest that the addition of supervised exercises to conventional treatment leads to faster and better recovery and a faster return to sport at short term follow-up than conventional treatment alone. In specific populations (athletes, soldiers, and patients with severe injuries) this evidence was restricted to a faster return to work and sport only. There was no strong evidence of effectiveness for any of the outcome measures. Most of the included studies had a high risk of bias, with few having adequate statistical power to detect clinically relevant differences. Conclusion Additional supervised exercises compared with conventional treatment alone have some benefit for recovery and return to sport in patients with ankle sprain, though the evidence is limited or moderate and many studies are subject to bias. PMID:20978065

  9. Comparative Evaluation of Efficacy of Physics Forceps versus Conventional Forceps in Orthodontic Extractions: A Prospective Randomized Split Mouth Study.

    PubMed

    Patel, Harsh S; Managutti, Anil M; Menat, Shailesh; Agarwal, Arvind; Shah, Dishan; Patel, Jigar

    2016-07-01

    Tooth extraction is one of the most commonly performed procedures in dentistry. It is usually a traumatic procedure often resulting in immediate destruction and loss of alveolar bone and surrounding soft tissues. Various instruments have been described to perform atraumatic extractions which can prevent damage to the paradental structures. Recently developed physics forceps is one of the instruments which is claimed to perform atraumatic extractions. The aim of the present study was to compare the efficacy of physics forceps with conventional forceps in terms of operating time, prevention of marginal bone loss & soft tissue loss, postoperative pain and postoperative complications following bilateral premolar extractions for orthodontic purpose. In this prospective split-mouth study, outcomes of the 2 groups (n = 42 premolars) requiring extraction of premolars for orthodontic treatment purpose using Physics forceps and Conventional forceps were compared. Clinical outcomes in form of time taken, loss of buccal soft tissue and buccal cortical plate based on extraction defect classification system, postoperative pain and other complication associated with extraction were recorded and compared. Statistically significant reduction in the operating time was noted in physics forceps group. Marginal bone loss and soft tissue loss was also significantly lesser in physics forceps group when compared to conventional forceps group. However, there was no statistically significant difference in severity of postoperative pain between both groups. The results of the present study suggest that physics forceps was more efficient in reducing operating time and prevention of marginal bone loss & soft tissue loss when compared to conventional forceps in orthodontically indicated premolar extractions.

  10. Comparative Study on the Efficacy of Gingival Retraction using Polyvinyl Acetate Strips and Conventional Retraction Cord – An in Vivo Study

    PubMed Central

    Shivasakthy, M.; Asharaf Ali, Syed

    2013-01-01

    Statement of Problem: A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. Purpose of the Study: This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Material and Methods: Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. Results were analyzed statistically using Paired students t-test. Results: The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Conclusion: Merocel strip produces more gingival displacement than the conventional retraction cord. PMID:24298531

  11. Novel biopsy forceps for diagnosis of biliary tract diseases during endoscopic retrograde cholangiopancreatography: a prospective comparative study with 90° adjustable and conventional biopsy forceps.

    PubMed

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori

    2012-01-01

    Recently, controllable biopsy forceps (MTW, D°sseldorf, Germany) have been developed. This biopsy forceps were 90° adjustable. In the present study, the feasibility and efficacy of the controllable biopsy forceps were compared with those of conventional biopsy forceps in patients with biliary tract disease. A total of 27 patients with biliary tract lesions were enrolled. We evaluated the procedure time, the sample tissue size and the diagnostic accuracy. In addition, the physicians performing the procedure rated their impressions about operability into 3 classes: excellent, fair and poor. The sensitivity in distinguishing benign from malignant lesions was 71.4% (15/21) for the 90° adjustable type and 66.7% (14/21) for the conventional type. The accuracy rate was 77.8% (21/27) for the 90° adjustable type and 74.0% (20/27) for the conventional type. In terms of operability as rated by each physician, the 'excellent' rate was given more frequently to the 90° adjustable type 25.9% than for the conventional type 11.1% (p=0.047). This preliminary study showed that controllable biopsy forceps compared to conventional type biopsy forceps, despite a larger diameter, enables biopsy in a similar procedure time and its ease of use was rated better.

  12. Comparison of emerging contaminants in receiving waters downstream of a conventional wastewater treatment plant and a forest-water reuse system.

    PubMed

    McEachran, Andrew D; Hedgespeth, Melanie L; Newton, Seth R; McMahen, Rebecca; Strynar, Mark; Shea, Damian; Nichols, Elizabeth Guthrie

    2018-05-01

    Forest-water reuse (FWR) systems treat municipal, industrial, and agricultural wastewaters via land application to forest soils. Previous studies have shown that both large-scale conventional wastewater treatment plants (WWTPs) and FWR systems do not completely remove many contaminants of emerging concern (CECs) before release of treated wastewater. To better characterize CECs and potential for increased implementation of FWR systems, FWR systems need to be directly compared to conventional WWTPs. In this study, both a quantitative, targeted analysis and a nontargeted analysis were utilized to better understand how CECs release to waterways from an FWR system compared to a conventional treatment system. Quantitatively, greater concentrations and total mass load of CECs was exhibited downstream of the conventional WWTP compared to the FWR. Average summed concentrations of 33 targeted CECs downstream of the conventional system were ~ 1000 ng/L and downstream of the FWR were ~ 30 ng/L. From a nontargeted chemical standpoint, more tentatively identified chemicals were present, and at a greater relative abundance, downstream of the conventional system as well. Frequently occurring contaminants included phthalates, pharmaceuticals, and industrial chemicals. These data indicate that FWR systems represent a sustainable wastewater treatment alternative and that emerging contaminant release to waterways was lower at a FWR system than a conventional WWTP.

  13. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  14. Conventional Gymnasium vs. Geodesic Field House. A Comparative Study of High School Physical Education and Assembly Facilities.

    ERIC Educational Resources Information Center

    Educational Facilities Labs., Inc., New York, NY.

    A description is presented of the design features of a high school's geodesic dome field house. Following consideration of various design features and criteria for the physical education facility, a comprehensive analysis is given of comparative costs of a geodesic dome field house and conventional gymnasium. On the basis of the study it would…

  15. Real-time compound sonography of the rotator-cuff: evaluation of artefact reduction and image definition.

    PubMed

    De Candia, Alessandro; Doratiotto, Stefsano; Paschina, Elio; Segatto, Enrica; Pelizzo, Francesco; Bazzocchi, Massimo

    2003-04-01

    The aim of this study was to compare real time compound sonography with conventional sonography in the evaluation of rotator cuff tears. A prospective study was performed on 50 supraspinatus tendons in 101 patients treated by surgical acromioplasty. The surgeon described 33 (66%) full-thickness tears and 17 (34%) partial-thickness tears. All tendons were examined by conventional sonography and real time compound sonography on the day before surgery. The techniques were compared by evaluating the images for freedom from artefacts, contrast resolution and overall image definition. Real time compound sonography proved to be superior to conventional sonography as regards freedom from artefacts in 50 cases out of 50 (100%). It was superior to conventional sonography in evaluating the image contrast resolution in 45 cases out of 50 (90%), and superior to conventional sonography in overall image definition in 45 out of 50 cases (90%). Real-time compound sonography reduces the intrinsic artefacts of conventional sonography and allows better overall image definition. In particular, the digital technique allowed us to study the rotator cuff with better contrast resolution and sharper and more detailed images than did conventional sonography.

  16. Medical experiments on persons with special needs, a comparative study of Islamic jurisprudence vs. Arab laws: UAE law as case study.

    PubMed

    Hammad, Hamza Abed Al-Karim

    2014-01-01

    This article is a comparative study of medical experiments on persons with special needs in Islamic jurisprudence and Arab laws; United Arab Emirates (UAE) law as case study. The current study adopts a comparative analytical and descriptive approach. The conclusion of this study points out that the Convention on the Rights of Persons with Special Needs, ratified by a number of Arab States, including the United Arab Emirates, approves conducting medical experiments on persons with special needs, subject to their free consent. As a result of ratifying this Convention, a number of special laws were enacted to be enforced in the United Arab Emirates. On the other hand, this issue is controversial from an Islamic jurisprudence point of view. One group of jurisprudents permits conducting these experimentations if they are designed to treat the person involved, and prohibits such experimentations for scientific advancement. Other jurisprudents permit conducting medical experimentations on persons with special needs, whether the purpose of such experimentations is treatment of the disabled or achieving scientific advancement. The opinion of this group is consistent with the International Convention and the Arab laws in this respect. However, neither the Convention nor the Arab laws regulate this matter by specific and comprehensive conditions, as addressed by some contemporary scholars. It is recommended that the Convention and the Arab laws adopt these conditions. Additionally, the Convention does not state whether the experimentations may be conducted for the interest of the person with disability or for the purpose of scientific advancement. The text of the Convention is unclear and therefore requires further illumination.

  17. Lipid profile in antipsychotic drug users: A comparative study

    PubMed Central

    Roohafza, Hamidreza; Khani, Azam; Afshar, Hamid; Garakyaraghi, Mohammad; Amirpour, Afshin; Ghodsi, Basir

    2013-01-01

    BACKGROUND Schizophrenic patients who receive antipsychotic drugs may be highly prone to metabolic disorders such as weight gain, dyslipidemia, and insulin resistance. The objective of the present study was to compare the effect of atypical and conventional antipsychotics on lipid profile. METHODS 128 schizophrenic patients were enrolled into the study. Patients were divided into two groups. One group had received one type of atypical antipsychotic drug, and, the other, one type of conventional antipsychotic drug. They were considered as atypical and conventional groups. Moreover, both groups had not used any other antipsychotic drugs during the past year. Demographic data and food frequency questionnaire were completed by the participants. Serum triglyceride, total cholesterol (TC), high-density lipoprotein and low-density lipoprotein (LDL) cholesterols, and apolipoprotein A and B (Apo B) were tested by blood sample drawing after 12 hours of fasting through the antecubital vein. Student’s t-test was used to compare atypical and conventional groups. RESULTS There was no significant difference in age, gender, duration of illness, period of drug consumption, and age at onset of illness in the two groups. Patients in the atypical group used clozapine and risperidone (46.9%) more than olanzapine. In the conventional group 81.3% of patients used phenothiazines. Comparison between lipid profile in the conventional and atypical groups showed a significantly higher mean in TC (P = 0.01), LDL (P = 0.03), and Apo B (P = 0.01) in conventional group than the atypical group. CONCLUSION In schizophrenic patients, the level of lipid profile had been increased in both atypical and conventional antipsychotic users, especially conventional users, so the effect of antipsychotic drugs should be investigated periodically. PMID:23766777

  18. Comparative Study of the Diagnostic Value of Panoramic and Conventional Radiography of the Wrist in Scaphoid Fractures

    PubMed Central

    Ezoddini Ardakani, Fatemeh; Zangoie Booshehri, Maryam; Banadaki, Seyed Hossein Saeed; Nafisi-Moghadam, Reza

    2012-01-01

    Background Scaphoid fractures are the most common type of carpal fractures. Objectives The aim of the study was to compare the diagnostic value of panoramic and conventional radiographs of the wrist in scaphoid fractures. Patients and Methods The panoramic and conventional radiographs of 122 patients with acute and chronic wrist trauma were studied. The radiographs were analyzed and examined by two independent radiologist observers; one physician radiologist and one maxillofacial radiologist. The final diagnosis was made by an orthopedic specialist. Kappa test was used for statistical calculations, inter- and intra-observer agreement and correlation between the two techniques. Results Wrist panoramic radiography was more accurate than conventional radiography for ruling out scaphoid fractures. There was an agreement in 85% or more of the cases. Agreement values were higher with better inter and intra observer agreement for panoramic examinations than conventional radiographic examinations. Conclusion The panoramic examination of the wrist is a useful technique for the diagnosis and follow-up of scaphoid fractures. Its use is recommended as a complement to conventional radiography in cases with inconclusive findings. PMID:23599708

  19. A work study of the CAD/CAM method and conventional manual method in the fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis.

    PubMed

    Wong, M S; Cheng, J C Y; Wong, M W; So, S F

    2005-04-01

    A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.

  20. Microbial analysis of meatballs cooled with vacuum and conventional cooling.

    PubMed

    Ozturk, Hande Mutlu; Ozturk, Harun Kemal; Koçar, Gunnur

    2017-08-01

    Vacuum cooling is a rapid evaporative cooling technique and can be used for pre-cooling of leafy vegetables, mushroom, bakery, fishery, sauces, cooked food, meat and particulate foods. The aim of this study was to apply the vacuum cooling and the conventional cooling techniques for the cooling of the meatball and to show the vacuum pressure effect on the cooling time, the temperature decrease and microbial growth rate. The results of the vacuum cooling and the conventional cooling (cooling in the refrigerator) were compared with each other for different temperatures. The study shows that the conventional cooling was much slower than the vacuum cooling. Moreover, the microbial growth rate of the vacuum cooling was extremely low compared with the conventional cooling. Thus, the lowest microbial growth occurred at 0.7 kPa and the highest microbial growth was observed at 1.5 kPa for the vacuum cooling. The mass loss ratio for the conventional cooling and vacuum cooling was about 5 and 9% respectively.

  1. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    PubMed Central

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901

  2. Evaluation of the white test for the intraoperative detection of bile leakage.

    PubMed

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  3. Navigated versus conventional total knee arthroplasty: A prospective study at three years follow-up.

    PubMed

    Martín-Hernández, C; Sanz-Sainz, M; Revenga-Giertych, C; Hernández-Vaquero, D; Fernández-Carreira, J M; Albareda-Albareda, J; Castillo-Palacios, A; Ranera-Garcia, M

    2018-03-28

    Computer-assisted surgery application in total knee arthroplasty (TKA) has shown more accurate implant alignment compared with conventional instrumentation and is associated with more homogeneous alignment results. Although longer implant survival and superior clinical outcomes should be expected from navigated TKA, currently available evidence does not support this hypothesis. The aim of this study was to compare navigated TKA with conventional TKA regarding clinical and radiological outcomes after a 3-year follow-up under the hypothesis that navigated TKA would provide better outcomes than conventional TKA. In a prospective multicentre study, 119 patients underwent navigated TKA and 80 patients received conventional instrumentation. Patients were evaluated at the baseline and at postoperative months 3, 12, 24, and 36. Analysis included the American Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short Form-12 (SF12) Health Survey, and radiographic assessment. All clinical scores improved significantly for all patients during the follow-up but were significantly better in the navigation group. The percentage of patients showing a mechanical axis between 3° of varus and 3° of valgus was significantly higher in the ATR group (93%) than in the conventional TKA group (71%) (P<.01). The use of computer-assisted surgery in TKA provides more accurate mechanical alignment and superior short-term functional outcomes compared to conventional TKA. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Comparative environmental and economic analysis of conventional and nanofluid solar hot water technologies.

    PubMed

    Otanicar, Todd P; Golden, Jay S

    2009-08-01

    This study compares environmental and economic impacts of using nanofluids to enhance solar collector efficiency as compared to conventional solar collectors for domestic hotwater systems. Results show that for the current cost of nanoparticles the nanofluid based solar collector has a slightly longer payback period but at the end of its useful life has the same economic savings as a conventional solar collector. The nanofluid based collector has a lower embodied energy (approximately 9%) and approximately 3% higher levels of pollution offsets than a conventional collector. In addition if 50% penetration of residential nanofluid based solar collector systems for hot water heating could be achieved in Phoenix, Arizona over 1 million metric tons of CO2 would be offset per year.

  5. Moderate quality evidence that surgical anchorage more effective than conventional anchorage during orthodontic treatment.

    PubMed

    Reynders, Reint Meursinge; de Lange, Jan

    2014-12-01

    Cochrane Oral Health Groups Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, key international orthodontic and dental journals and the World Health Organization (WHO) International Clinical Trials Registry Platform. Randomised controlled trials comparing surgical anchorage with conventional anchorage in orthodontic patients. Trials comparing two types of surgical anchorage were also included. Data extraction was performed independently and in duplicate by three review authors and the Cochrane risk of bias tool was used to assess bias. Random-effects meta-analysis was used for more than three studies when pooling of the data was clinically and statistically appropriate. Fixed-effect analysis was undertaken with two or three studies. Fifteen studies, involving 543 analysed participants, were included. Five ongoing studies were identified. Eight studies were assessed to be at high overall risk of bias, six at unclear risk and one study at low risk of bias. Ten studies (407 randomised and 390 analysed patients) compared surgical anchorage with conventional anchorage for the primary outcome. A random-effects meta-analysis of seven studies for the primary outcome found strong evidence of an effect of surgical anchorage. Compared with conventional anchorage, surgical anchorage was more effective in the reinforcement of anchorage by 1.68 mm (95% CI -2.27 mm to -1.09 mm) (moderate quality evidence). This result should be interpreted with some caution, however, as there was a substantial degree of heterogeneity for this comparison. There was no evidence of a difference in overall duration of treatment between surgical and conventional anchorage (low quality of evidence).Information on patient-reported outcomes such as pain and acceptability was limited and inconclusive. When direct comparisons were made between two types of surgical anchorage, there was a lack of evidence to suggest that any one technique was better than another. There is moderate quality evidence that reinforcement of anchorage is more effective with surgical anchorage than conventional anchorage, and that results from mini-screw implants are particularly promising. While surgical anchorage is not associated with the inherent risks and compliance issues related to extra-oral headgear, none of the included studies reported on harms of surgical or conventional anchorage.

  6. Case study: Differences in milk characteristics between a cow herd transitioning to organic versus milk from a conventional dairy herd

    USDA-ARS?s Scientific Manuscript database

    Differences between organic and conventional milk were studied by comparing two adjacent farms over a 12-mo period starting at the beginning of the grazing season, thus eliminating variables due to geography and weather. Milk was collected from a farm where cows were fed a conventional total mixed ...

  7. Transumbilical Thoracoscopy Versus Conventional Thoracoscopy for Lung Wedge Resection: Safety and Efficacy in a Live Canine Model.

    PubMed

    Chen, Tzu-Ping; Yen-Chu; Wu, Yi-Cheng; Yeh, Chi-Ju; Liu, Chien-Ying; Hsieh, Ming-Ju; Yuan, Hsu-Chia; Ko, Po-Jen; Liu, Yun-Hen

    2015-12-01

    Transumbilical single-port surgery has been associated with less postoperative pain and offers better cosmetic outcomes than conventional 3-port laparoscopic surgery. This study compares the safety and efficacy of transumbilical thoracoscopy and conventional thoracoscopy for lung wedge resection. The animals (n = 16) were randomly assigned to the transumbilical thoracoscopic approach group (n = 8) or conventional thoracoscopic approach group (n = 8). Transumbilical lung resection was performed via an umbilical incision and a diaphragmatic incision. In the conventional thoracoscopic group, lung resection was completed through a thoracic incision. For both procedures, we compared the surgical outcomes, for example, operating time and operative complications; physiologic parameters, for example, respiratory rate and body temperature; inflammatory parameters, for example, white blood cell count; and pulmonary parameters, for example, arterial blood gas levels. The animals were euthanized 2 weeks after the surgery for gross and histologic evaluations. The lung wedge resection was successfully performed in all animals. There was no significant difference in the mean operating times or complications between the transumbilical and the conventional thoracoscopic approach groups. With regard to the physiologic impact of the surgeries, the transumbilical approach was associated with significant elevations in body temperature on postoperative day 1, when compared with the standard thoracoscopic approach. This study suggests that both approaches for performing lung wedge resection were comparable in efficacy and postoperative complications. © The Author(s) 2014.

  8. Live Interviews Conducted at the 1988 GOP Convention by ABC, CBS, NBC, and CNN.

    ERIC Educational Resources Information Center

    Womack, David L.

    To compare broadcast coverage of the 1984 and 1988 GOP Conventions, a study asked three research questions: (1) Did live interviews represent the same number of sources interviewed during broadcasts of the 1988 GOP convention by the four networks as during the 1984 convention? (2) Did 1988 live interview sources have the same distribution with…

  9. Comparative Study on the Efficacy of Gingival Retraction using Polyvinyl Acetate Strips and Conventional Retraction Cord - An in Vivo Study.

    PubMed

    Shivasakthy, M; Asharaf Ali, Syed

    2013-10-01

    A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. RESULTS were analyzed statistically using Paired students t-test. The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Merocel strip produces more gingival displacement than the conventional retraction cord.

  10. Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients.

    PubMed

    Mangano, Alessandro; Beretta, Matteo; Luongo, Giuseppe; Mangano, Carlo; Mangano, Francesco

    2018-01-01

    The objective of the present study was to compare patients' acceptability, comfort and stress with conventional and digital impressions. Thirty young orthodontic patients (15 males and 15 females) who had no previous experience of impressions were enrolled in this study. Conventional impressions for orthodontic study models of the dental arches were taken using an alginate impression material (Hydrogum ® , Zhermack Spa, Badia Polesine, Rovigo, Italy). Fifteen days later, digital impressions of both arches were acquired using an intraoral scanner (CS3600 ® , Carestream Dental, Rochester, NY, USA). Immediately after impression taking, patients' acceptability, comfort and stress were measured using two questionnaires and the State anxiety scale. Data showed no difference in terms of anxiety and stress; however, patients preferred the use of digital impressions systems instead of conventional impression techniques. Alginate impressions resulted as fast as digital impressions. Digital impressions resulted the most accepted and comfortable impression technique in young orthodontic patients, when compared to conventional techniques.

  11. Laparoendoscopic single-site surgery varicocelectomy versus conventional laparoscopic varicocele ligation: A meta-analysis

    PubMed Central

    Li, Mingchao; Wang, Zhengyun

    2016-01-01

    Objective To perform a meta-analysis of data from available published studies comparing laparoendoscopic single-site surgery varicocelectomy (LESSV) with conventional transperitoneal laparoscopic varicocele ligation. Methods A comprehensive data search was performed in PubMed and Embase to identify randomized controlled trials and comparative studies that compared the two surgical approaches for the treatment of varicoceles. Results Six studies were included in the meta-analysis. LESSV required a significantly longer operative time than conventional laparoscopic varicocelectomy but was associated with significantly less postoperative pain at 6 h and 24 h, a shorter recovery time and greater patient satisfaction with the cosmetic outcome. There was no difference between the two surgical approaches in terms of postoperative semen quality or the incidence of complications. Conclusion These data suggest that LESSV offers a well tolerated and efficient alternative to conventional laparoscopic varicocelectomy, with less pain, a shorter recovery time and better cosmetic satisfaction. Further well-designed studies are required to confirm these findings and update the results of this meta-analysis. PMID:27688686

  12. Advantages of laparoscopic compared to conventional surgery are not related to an innate immune response of peritoneal immune activation: an animal study in rats.

    PubMed

    Lingohr, Philipp; Dohmen, Jonas; Matthaei, Hanno; Schwandt, Timo; Stein, Kathy; Hong, Gun-Soo; Steitz, Julia; Longerich, Thomas; Bölke, Edwin; Wehner, Sven; Kalff, Jörg C

    2017-06-01

    Laparoscopic surgery (LS) has proved superior compared to conventional surgery (CS) regarding morbidity, length of hospital stay, rate of wound infection and time until recovery. An improved preservation of the postoperative immune function is assumed to contribute to these benefits though the role of the local peritoneal immune response is still poorly understood. Our study investigates the peritoneal immune response subsequent to abdominal surgery and compares it between laparoscopic and conventional surgery to find an immunological explanation for the clinically proven benefits of LS. Wistar rats (N = 140) underwent laparoscopic cecum resection (LCR; N = 28), conventional cecum resection (CCR; N = 28), laparoscopic sham operation (LSO; N = 28), conventional sham operation (CSO; N = 28), or no surgical treatment (CTRL; N = 28). Postoperatively, peritoneal lavages were performed, leukocytes isolated and analyzed regarding immune function and phagocytosis activity. Immune function was inhibited postoperatively in animals undergoing LCR or CCR compared to CTRL reflected by a lower TNF-α (CTRL 3956.65 pg/ml, LCR 2018.48 pg/ml (p = 0.023), CCR 2793.78 pg/ml (n.s.)) and IL-6 secretion (CTRL 625.84 pg/ml, LCR 142.84 pg/ml (p = 0.009), CCR 169.53 pg/ml (p = 0.01)). Phagocytosis was not affected in rats undergoing any kind of surgery compared to CTRL. Neither cytokine secretion nor phagocytosis activity differed significantly between laparoscopic and conventional surgery. According to our findings the benefits associated with LS compared to CS cannot be explained by differences in the postoperative peritoneal innate immune response. Further studies are needed to elucidate the causes for a more favorable postoperative outcome in patients after LS compared to CS.

  13. Expert advice provided through telemedicine improves healing of chronic wounds: prospective cluster controlled study.

    PubMed

    Zarchi, Kian; Haugaard, Vibeke B; Dufour, Deirdre N; Jemec, Gregor B E

    2015-03-01

    Telemedicine is widely considered as an efficient approach to manage the growing problem of chronic wounds. However, to date, there is no convincing evidence to support the clinical efficacy of telemedicine in wound management. In this prospective cluster controlled study, we tested the hypothesis that advice on wound management provided by a team of wound-care specialists through telemedicine would significantly improve the likelihood of wound healing compared with the best available conventional practice. A total of 90 chronic wound patients in home care met all study criteria and were included: 50 in the telemedicine group and 40 in the conventional group. Patients with pressure ulcers, surgical wounds, and cancer wounds were excluded. During the 1-year follow-up, complete wound healing was achieved in 35 patients (70%) in the telemedicine group compared with 18 patients (45%) in the conventional group. After adjusting for important covariates, offering advice on wound management through telemedicine was associated with significantly increased healing compared with the best available conventional practice (telemedicine vs. conventional practice: adjusted hazard ratio 2.19; 95% confidence interval: 1.15-4.17; P=0.017). This study strongly supports the use of telemedicine to connect home-care nurses to a team of wound experts in order to improve the management of chronic wounds.

  14. Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T.

    PubMed

    Prakkamakul, Supada; Witzel, Thomas; Huang, Susie; Boulter, Daniel; Borja, Maria J; Schaefer, Pamela; Rosen, Bruce; Heberlein, Keith; Ratai, Eva; Gonzalez, Gilberto; Rapalino, Otto

    2016-09-01

    To compare an ultrafast brain magnetic resonance imaging (MRI) protocol to the conventional protocol in motion-prone inpatient clinical settings. This retrospective study was HIPAA compliant and approved by the Institutional Review Board with waived inform consent. Fifty-nine inpatients (30 males, 29 females; mean age 55.1, range 23-93 years)who underwent 3-Tesla brain MRI using ultrafast and conventional protocols, both including five sequences, were included in the study. The total scan time for five ultrafast sequences was 4 minutes 59 seconds. The ideal conventional acquisition time was 10 minutes 32 seconds but the actual acquisition took 15-20 minutes. The average scan times for ultrafast localizers, T1-weighted, T2-weighted, fluid-attenuated inversion recovery (FLAIR), diffusion-weighted, T2*-weighted sequences were 14, 41, 62, 96, 80, 6 seconds, respectively. Two blinded neuroradiologists independently assessed three aspects: (1) image quality, (2) gray-white matter (GM-WM) differentiation, and (3) diagnostic concordance for the detection of six clinically relevant imaging findings. Wilcoxon signed-rank test was used to compare image quality and GM-WM scores. Interobserver reproducibility was calculated. The ultrafast T1-weighted sequence demonstrated significantly better image quality (P = .005) and GM-WM differentiation (P < .001) compared to the conventional sequence. There was high agreement (>85%) between both protocols for the detection of mass-like lesion, hemorrhage, diffusion restriction, WM FLAIR hyperintensities, subarachnoid FLAIR hyperintensities, and hydrocephalus. The ultrafast protocol achieved at least comparable image quality and high diagnostic concordance compared to the conventional protocol. This fast protocol can be a viable option to replace the conventional protocol in motion-prone inpatient clinical settings. Copyright © 2016 by the American Society of Neuroimaging.

  15. Incidence of tardive dyskinesia with atypical versus conventional antipsychotic medications: a prospective cohort study.

    PubMed

    Woods, Scott W; Morgenstern, Hal; Saksa, John R; Walsh, Barbara C; Sullivan, Michelle C; Money, Roy; Hawkins, Keith A; Gueorguieva, Ralitza V; Glazer, William M

    2010-04-01

    Most previous studies of the incidence of tardive dyskinesia with atypical antipsychotics compared with conventional antipsychotics have not had tardive dyskinesia as their primary focus. The current study aimed to compare the incidence of tardive dyskinesia with atypical vs conventional antipsychotics using methods similar to those from a previous prospective cohort study at our site in the 1980s. Three hundred fifty-two initially tardive dyskinesia-free psychiatric outpatients (diagnosed at baseline using the Structured Clinical Interview for DSM-IV) were examined for a new diagnosis of tardive dyskinesia (using the Abnormal Involuntary Movement Scale and Glazer-Morgenstern criteria) every 6 months for up to 4 years at a community mental health center. At baseline, subjects were receiving conventional antipsychotics only (23%), atypicals only (64%), or both (14%). Only 26 subjects had never received conventional antipsychotics. Baseline evaluations were conducted from November 2000 through May 2003. Follow-ups were conducted through February 2005. Compared with subjects treated with conventional antipsychotics alone since the previous visit, the adjusted tardive dyskinesia incidence rate-ratio for subjects treated with atypical antipsychotics alone was 0.68 (95% CI, 0.29-1.64). The incidence and prevalence of tardive dyskinesia was similar to previous findings at this site in the 1980s. The incidence of tardive dyskinesia with recent exposure to atypical antipsychotics alone was more similar to that for conventional antipsychotics than in most previous studies. Despite high penetration of atypical antipsychotics into clinical practice, the incidence and prevalence of tardive dyskinesia appeared relatively unchanged since the 1980s. Clinicians should continue to monitor for tardive dyskinesia, and researchers should continue to pursue efforts to treat or prevent it. Copyright 2010 Physicians Postgraduate Press, Inc.

  16. Evaluation of the Amount of Debris extruded apically by using Conv-entional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study

    PubMed Central

    Tambe, Varsha H; Nagmode, Pradnya S; Vishwas, Jayshree R; P, Saujanya K; Angadi, Prabakar; Ali, Fareedi Mukram

    2013-01-01

    Background: To compare the amount of debris extruded apically by using conventional syringe, Endovac & Ultrasonic irrigation. Materials & Methods: Thirty freshly extracted mandibular premolars were selected, working length was determined and mounted in a debris and collection apparatus. The canals were prepared. After each instrument change, 1 ml. of 3% sodium hypochlorite was used as irrigation. Debris extruded apically by using conventional syringe, endovac& ultrasonic irrigation tech, was measured using the electronic balance to determine its weight and statistical analysis was performed. The mean difference between the groups was determined using statistical analysis within the groups &between the groups for equal variances. Results: Among all the groups, significantly less debris were found apically in the Endovac group (0.96) compared to conventional and ultrasonic group (1.23) syringe. Conclusion: The present study showed that endovac system extrudes less amount of debris apically as compared to ultrasonic followed by conventional so incidence of flare up can be reduce by using endovac irrigation system. How to cite this article: Tambe V H, Nagmode P S, Vishwas J R, Saujanya K P, Angadi P, Ali F M. Evaluation of the Amount of Debris extruded apically by using Conventional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study. J Int Oral Health 2013; 5(3):63-66. PMID:24155604

  17. Comparative Assessment of Conventional Composites and Coloured Compomers in Permanent Molars of Children with Mixed Dentition: A Pilot Study

    PubMed Central

    Kohli, Divyata; Badakar, Chandrashekhar M; Vyavahare, Supriya S; Shah, Parin P; Gokhale, Niraj S; Patel, Punit M; Mundada, Madhura V

    2017-01-01

    Introduction Early treatment of carious lesions in children is important for the maintenance of oral health. Multicoloured restorations could be the impetus for an extremely nervous or defiant child to take dental treatment. Aim The aim of this study was to assess and compare the clinical success of conventional composites and coloured compomer material in first permanent molars of children with mixed dentition. Materials and Methods A total of sixty sites, divided into two groups, with thirty subjects in each group using split mouth design were chosen amongst patients reporting to Department of Pedodontics and Preventive Dentistry. In control group conventional composites were placed, similarly coloured compomers were placed in experimental group under standard operating protocol. Patients were recalled for assessment of clinical success amongst control as well as experimental group at regular intervals of one; three and six months follow up based on Modified Ryge’s Criteria. Statistical analysis was done using Chi-square test using SPSS version 20.0 (Chicago, USA). Results Both conventional composites and coloured compomers had comparable retention rates in terms of anatomical form, marginal integrity, secondary caries and marginal discolouration. Conclusion The coloured compomer material showed promising results in this six month follow up study in permanent molars and had properties comparable to that of conventional composites. PMID:28764297

  18. Comparison of retention between maxillary milled and conventional denture bases: A clinical study.

    PubMed

    AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J

    2017-02-01

    Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. COMPARISON OF CONVENTIONAL AND PROGRAMED INSTRUCTION IN TEACHING AVIONICS FUNDAMENTALS.

    ERIC Educational Resources Information Center

    LONGO, ALEXANDER A.; MAYO, G. DOUGLAS

    THIS STUDY, PART OF A SERIES INVOLVING A VARIETY OF COURSE CONTENT AND TRAINING CONDITIONS, COMPARED PROGRAMED INSTRUCTION WITH CONVENTIONAL INSTRUCTION TO GAIN INFORMATION ABOUT THE GENERAL UTILITY OF PROGRAMED METHODS. THE PERFORMANCE OF 200 NAVY TRAINEES TAKING 26 HOURS OF CONVENTIONAL INSTRUCTION IN ELECTRICAL CALCULATIONS, DIRECT CURRENT…

  20. A Comparison of Programed Instruction with Conventional Methods for Teaching Two Units of Eighth Grade Science.

    ERIC Educational Resources Information Center

    Eshleman, Winston Hull

    Compared were programed materials and conventional methods for teaching two units of eighth grade science. Programed materials used were linear programed books requiring constructed responses. The conventional methods included textbook study, written exercises, lectures, discussions, demonstrations, experiments, chalkboard drawings, films,…

  1. Perceptions of the Harm and Addictiveness of Conventional Cigarette Smoking Among Adolescent E-Cigarette Users.

    PubMed

    Owotomo, Olusegun; Maslowsky, Julie; Loukas, Alexandra

    2018-01-01

    Although existing evidence indicates that e-cigarette use is a risk factor for cigarette smoking initiation, mechanisms of this association are not yet known. E-cigarette users perceive e-cigarette use to be less harmful relative to conventional cigarettes, but their absolute perceptions of addictiveness of conventional cigarette smoking are unknown. This study examines how e-cigarette users compare with nonusers (non-e-cigarette users/nonconventional cigarette smokers), conventional cigarette smokers, and dual users on perceptions of harm and the addictiveness of conventional cigarette smoking and on other known predictors of cigarette smoking such as peer smoking, influence of antismoking ads, and risk-taking propensity. National samples of 8th- and 10th-grade students from 2014 and 2015 (N = 14,151) were obtained from the Monitoring the Future Study. Multivariate logistic regression models were used to examine relationships between adolescent smoking status and perceptions of harm and the addictiveness of conventional cigarette smoking while controlling for potential confounders. E-cigarette users had lower perceptions of the addictiveness of conventional cigarette smoking compared with nonusers but higher than cigarette smokers and dual users. E-cigarette users reported lower influence by antismoking ads, more conventional cigarette-smoking peers, and greater risk-taking propensity than nonusers. E-cigarette users and cigarette smokers did not differ in their perceived harm of conventional cigarette smoking or in their risk-taking propensity. E-cigarette users' attitudes and perceptions regarding conventional cigarette smoking may leave them vulnerable to becoming conventional cigarette smokers. Future studies should explore the prospective relationship between smoking-related perceptions of conventional cigarette smoking among e-cigarette users and the onset of cigarette smoking. Copyright © 2017 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  2. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    PubMed

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  3. A clinical comparative study between conventional and camouflaged syringes to evaluate behavior and anxiety in 6-11-year-old children during local anesthesia administration-a novel approach.

    PubMed

    Melwani, Anjana M; Srinivasan, Ila; Setty, Jyothsna V; D R, Murali Krishna; Pamnani, Sunaina S; Lalitya, Dandamudi

    2018-02-01

    The sight of dental injection can bring about severe anxiety in children. Therefore, an alternative method that is convenient, effective, and keeps the needle hidden making it child friendly is necessary. The objective of the study was to compare the efficacy of a camouflaged syringe and conventional syringe on behavior and anxiety in 6-11-year-old children during local anesthesia administration. The study was a randomized, crossover clinical study including 30 children. Children were separated into two groups. Group 1 consisted of 15 children aged 6-8 years while group 2 consisted of 15 children aged 9-11 years. This study involved two sessions wherein all the children were injected using conventional and camouflaged syringes in separate sessions. Their behavior was assessed using the Faces, Legs, Activity, Cry, Consolability (FLACC) behavior pain scale and anxiety was assessed by measuring changes in pulse rate. Patient and operator preferences were compared. The results showed a lower mean change in pulse rate and FLACC scores in the camouflaged group, suggesting a positive behavior and lesser anxiety with camouflaged syringes than with conventional syringes. The use of camouflaged syringes for anesthesia was demonstrated to be effective in improving the behavior of children and decreasing their anxiety, and is therefore recommended as an alternative to the use of conventional syringes for local anesthesia.

  4. Levonorgestrel-Releasing Intrauterine System versus Medical Therapy for Menorrhagia: A Systematic Review and Meta-Analysis

    PubMed Central

    Qiu, Jin; Cheng, Jiajing; Wang, Qingying; Hua, Jie

    2014-01-01

    Background The aim of this study was to compare the effects of the levonorgestrel-releasing intrauterine system (LNG-IUS) with conventional medical treatment in reducing heavy menstrual bleeding. Material/Methods Relevant studies were identified by a search of MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and clinical trials registries (from inception to April 2014). Randomized controlled trials comparing the LNG-IUS with conventional medical treatment (mefenamic acid, tranexamic acid, norethindrone, medroxyprogesterone acetate injection, or combined oral contraceptive pills) in patients with menorrhagia were included. Results Eight randomized controlled trials that included 1170 women (LNG-IUS, n=562; conventional medical treatment, n=608) met inclusion criteria. The LNG-IUS was superior to conventional medical treatment in reducing menstrual blood loss (as measured by the alkaline hematin method or estimated by pictorial bleeding assessment chart scores). More women were satisfied with the LNG-IUS than with the use of conventional medical treatment (odds ratio [OR] 5.19, 95% confidence interval [CI] 2.73–9.86). Compared with conventional medical treatment, the LNG-IUS was associated with a lower rate of discontinuation (14.6% vs. 28.9%, OR 0.39, 95% CI 0.20–0.74) and fewer treatment failures (9.2% vs. 31.0%, OR 0.18, 95% CI 0.10–0.34). Furthermore, quality of life assessment favored LNG-IUS over conventional medical treatment, although use of various measurements limited our ability to pool the data for more powerful evidence. Serious adverse events were statistically comparable between treatments. Conclusions The LNG-IUS was the more effective first choice for management of menorrhagia compared with conventional medical treatment. Long-term, randomized trials are required to further investigate patient-based outcomes and evaluate the cost-effectiveness of the LNG-IUS and other medical treatments. PMID:25245843

  5. Anti-TNF-A therapy about infliximab and adalimamab for the effectiveness in ulcerative colitis compared with conventional therapy: a meta-analysis.

    PubMed

    Zhou, Zheng; Dai, Cong; Liu, Wei-Xin

    2015-01-01

    TNF-α has an important role in the pathogenesis of ulcerative colitis (UC). It seems that anti-TNF-α therapy is beneficial in the treatment of UC. The aim was to assess the effectiveness of Infliximab and Adalimamab with UC compared with conventional therapy. The Pubmed and Embase databases were searched for studies investigating the efficacy of infliximab and adalimumab on UC. Infliximab had a statistically significant effects in induction of clinical response (RR = 1.67; 95% CI 1.12 to 2.50) of UC compared with conventional therapy, but those had not a statistically significant effects in clinical remission (RR = 1.63; 95% CI 0.84 to 3.18) and reduction of colectomy rate (RR = 0.54; 95% CI 0.26 to 1.12) of UC. And adalimumab had a statistically significant effects in induction of clinical remission (RR = 1.82; 95% CI 1.24 to 2.67) and clinical response (RR = 1.36; 95% CI 1.13 to 1.64) of UC compared with conventional therapy. Our meta-analyses suggested that Infliximab had a statistically significant effects in induction of clinical response of UC compared with conventional therapy and adalimumab had a statistically significant effects in induction of clinical remission and clinical response of UC compared with conventional therapy.

  6. Programmed Instruction in Secondary Education: A Meta-Analysis of the Impact of Class Size on Its Effectiveness.

    ERIC Educational Resources Information Center

    Boden, Andrea; Archwamety, Teara; McFarland, Max

    This review used meta-analytic techniques to integrate findings from 30 independent studies that compared programmed instruction to conventional methods of instruction at the secondary level. The meta-analysis demonstrated that programmed instruction resulted in higher achievement when compared to conventional methods of instruction (average…

  7. Comparison of Performance Due to Guided Hyperlearning, Unguided Hyperlearning, and Conventional Learning in Mathematics: An Empirical Study

    ERIC Educational Resources Information Center

    Fathurrohman, Maman; Porter, Anne; Worthy, Annette L.

    2014-01-01

    In this paper, the use of guided hyperlearning, unguided hyperlearning, and conventional learning methods in mathematics are compared. The design of the research involved a quasi-experiment with a modified single-factor multiple treatment design comparing the three learning methods, guided hyperlearning, unguided hyperlearning, and conventional…

  8. Achievement of Audi-Tutorial and Conventional Biology Students, A Comparative Study

    ERIC Educational Resources Information Center

    Sparks, Phillip D.; Unbehaun, Laraine M.

    1971-01-01

    Students studying a biology course by audio-tutorial or conventional lecture-laboratory methods differed in achievement on course examinations, with the A-T group scoring significantly higher on the total test and 3 of the 9 subtests. (AL)

  9. Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings.

    PubMed

    Andreadis, Emmanuel A; Geladari, Charalampia V; Angelopoulos, Epameinondas T; Savva, Florentia S; Georgantoni, Anna I; Papademetriou, Vasilios

    2018-04-07

    Automated office blood pressure (AOBP) measurement is superior to conventional office blood pressure (OBP) because it eliminates the "white coat effect" and shows a strong association with ambulatory blood pressure. We conducted a cross-sectional study in 146 participants with office hypertension, and we compared AOBP readings, taken with or without the presence of study personnel, before and after the conventional office readings to determine whether their variation in blood pressure showed a difference in blood pressure values. We also compared AOBP measurements with daytime ambulatory blood pressure monitoring and conventional office readings. The mean age of the studied population was 56±12 years, and 53.4% of participants were male. Bland-Altman analysis revealed a bias (ie, mean of the differences) of 0.6±6 mm Hg systolic for attended AOBP compared with unattended and 1.4±6 and 0.1±6 mm Hg bias for attended compared with unattended systolic AOBP when measurements were performed before and after conventional readings, respectively. A small bias was observed when unattended and attended systolic AOBP measurements were compared with daytime ambulatory blood pressure monitoring (1.3±13 and 0.6±13 mm Hg, respectively). Biases were higher for conventional OBP readings compared with unattended AOBP (-5.6±15 mm Hg for unattended AOBP and oscillometric OBP measured by a physician, -6.8±14 mm Hg for unattended AOBP and oscillometric OBP measured by a nurse, and -2.1±12 mm Hg for unattended AOBP and auscultatory OBP measured by a second physician). Our findings showed that independent of the presence or absence of medical staff, AOBP readings revealed similar values that were closer to daytime ambulatory blood pressure monitoring than conventional office readings, further supporting the use of AOBP in the clinical setting. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Self-disinfecting Alginate vs Conventional Alginate: Effect on Surface Hardness of Gypsum Cast-An in vitro Study.

    PubMed

    Madhavan, Ranjith; George, Navia; Thummala, Niharika R; Ravi, S V; Nagpal, Ajay

    2017-11-01

    For the construction of any dental prosthesis, accurate impressions are necessary. Hence, we undertook the present study to evaluate and compare the surface hardness of gypsum casts poured from impressions made using conventional alginate and self-disinfecting alginate. A total of 30 impressions of stainless steel die were made, out of which 15 impressions were made with conventional alginate and 15 were made with self-disinfecting alginate and poured using Type III dental stone. Thirty stone specimens were subjected for hardness testing. Data were analyzed using independent samples t-test to compare the mean surface hardness. Difference in surface hardness was statistically insignificant (p > 0.05). Surface hardness of gypsum casts poured using impressions made from self-disinfecting alginate and conventional alginates were comparable. Self-disinfecting alginates may be employed in clinical practice as safe and effective materials to overcome the infection control issues without compromising on the properties of the material.

  11. The utility of indocyanine green fluorescence imaging during robotic adrenalectomy.

    PubMed

    Colvin, Jennifer; Zaidi, Nisar; Berber, Eren

    2016-08-01

    Indocyanine green (ICG) has been used for medical imaging since 1950s, but has more recently become available for use in minimally invasive surgery owing to improvements in technology. This study investigates the use of ICG florescence to guide an accurate dissection by delineating the borders of adrenal tumors during robotic adrenalectomy (RA). This prospective study compared conventional robotic view with ICG fluorescence imaging in 40 consecutive patients undergoing RA. Independent, non-blinded observers assessed how accurately ICG fluorescence delineated the borders of adrenal tumors compared to conventional robotic view. A total of 40 patients underwent 43 adrenalectomies. ICG imaging was superior, equivalent, or inferior to conventional robotic view in 46.5% (n = 20), 25.6% (n = 11), and 27.9% (n = 12) of the procedures. On univariate analysis, the only parameter that predicted the superiority of ICG imaging over conventional robotic view was the tumor type, with adrenocortical tumors being delineated more accurately on ICG imaging compared to conventional robotic view. This study demonstrates the utility of ICG to guide the dissection and removal of adrenal tumors during RA. A simple reproducible method is reported, with a detailed description of the utility based on tumor type, approach and side. J. Surg. Oncol. 2016;114:153-156. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Movement quality of conventional prostheses and the DEKA Arm during everyday tasks

    PubMed Central

    Cowley, Jeffrey; Resnik, Linda; Wilken, Jason; Walters, Lisa Smurr; Gates, Deanna

    2017-01-01

    Background Conventional prosthetic devices fail to restore the function and characteristic movement quality of the upper limb. The DEKA Arm is a new, advanced prosthesis featuring a compound, powered wrist and multiple grip configurations. Objectives The purpose of this study was to determine if the DEKA Arm improved the movement quality of upper limb prosthesis users compared to conventional prostheses. Study design Case series. Methods Three people with transradial amputation completed tasks of daily life with their conventional prosthesis and with the DEKA Arm. A total of 10 healthy controls completed the same tasks. The trajectory of the wrist joint center was analyzed to determine how different prostheses affected movement duration, speed, smoothness, and curvature compared to patients’ own intact limbs and controls. Results Movement quality decreased with the DEKA Arm for two participants, and increased for the third. Prosthesis users made slower, less smooth, more curved movements with the prosthetic limb compared to the intact limb and controls, particularly when grasping and manipulating objects. Conclusion The effects of one month of training with the DEKA Arm on movement quality varied with participants’ skill and experience with conventional prostheses. Future studies should examine changes in movement quality after long-term use of advanced prostheses. PMID:26932980

  13. A comparison between conventional and digital radiography in root canal working length determination.

    PubMed

    Farida, Abesi; Maryam, Ehsani; Ali, Mirzapour; Ehsan, Moudi; Sajad, Yousefi; Soraya, Khafri

    2013-01-01

    Obtaining a correct working length is necessary for successful root canal treatment. The aim of this study was to compare conventional and digital radiography in measuring root canal working length. In this in vitro study 20 mesio buccal canal from maxillary first molars with moderate and severe curvature and 20 canal form anterior teeth with mild curvature were chosen and their working length were measured with number 15 k file (Maillefer, DENTSPLY, Germany). Then for each canal five radiographies were taken, three conventional radiographies using three methods of processing: Manual, automatic, and monobath solution; in addition to two other digital radiographies using CCD and PSP receptors. Two independent observers measured working length in each technique. Finally, the mean of working length in each group was compared with real working length using a paired T-test. Also a one-way ANOVA test was used for comparing the two groups. The level of statistical significance was P < 0.05. The results have shown that there was a high interobserver agreement on the measurements of the working length in conventional and digital radiography (P ≤ 0.001). Also there was no significant difference between conventional and digital radiography in measuring working length (P > 0.05). Therefore it was concluded that the accuracy of digital radiography is comparable with conventional radiography in measuring working length, so considering the advantages of the digital radiography, it can be used for working length determination.

  14. Single incision laparoscopic surgery for appendicectomy: a retrospective comparative analysis.

    PubMed

    Chow, Andre; Purkayastha, Sanjay; Nehme, Jean; Darzi, Lord Ara; Paraskeva, Paraskevas

    2010-10-01

    Single incision laparoscopic surgery (SILS) may further reduce the trauma of surgery leading to reduced port site complications and postoperative pain. The improved cosmetic result also may lead to improved patient satisfaction with surgery. Data were prospectively collected and retrospectively analyzed for all patients who underwent SILS appendicectomy at our institution and were compared with those who had undergone conventional laparoscopic appendicectomy during the same time period. This included patient demographic data, intraoperative, and postoperative outcomes. Thirty-three patients underwent conventional laparoscopic appendicectomy and 40 patients underwent SILS appendicectomy between January 26, 2008 and July 14, 2009. Operative time was shorter with SILS appendicectomy compared with conventional laparoscopic appendicectomy (p < 0.05). No patients in the SILS appendicectomy group required conversion to open surgery compared with two patients in the conventional laparoscopic appendicectomy group. Patients stayed an average of 1.36 days after SILS appendicectomy, and 2.36 days after conventional laparoscopic appendicectomy. SILS appendicectomy seems to be a safe and efficacious technique. Further work in the form of randomized studies is required to investigate any significant advantages of this new and attractive technique.

  15. Functional MRI of Conventional and Anomalous Metaphors in Mandarin Chinese

    ERIC Educational Resources Information Center

    Ahrens, Kathleen; Liu, Ho-Ling; Lee, Chia-Ying; Gong, Shu-Ping; Fang, Shin-Yi; Hsu, Yuan-Yu

    2007-01-01

    This study looks at whether conventional and anomalous metaphors are processed in different locations in the brain while being read when compared with a literal condition in Mandarin Chinese. We find that conventional metaphors differ from the literal condition with a slight amount of increased activation in the right inferior temporal gyrus. In…

  16. Root resorption during orthodontic treatment with self-ligating or conventional brackets: a systematic review and meta-analysis.

    PubMed

    Yi, Jianru; Li, Meile; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2016-11-21

    The aim of this study was to compare the external apical root resorption (EARR) in patients receiving fixed orthodontic treatment with self-ligating or conventional brackets. Studies comparing the EARR between orthodontic patients using self-ligating or conventional brackets were identified through electronic search in databases including CENTRAL, PubMed, EMBASE, China National Knowledge Infrastructure (CNKI) and SIGLE, and manual search in relevant journals and reference lists of the included studies until Apr 2016. The extraction of data and risk of bias evaluation were conducted by two investigators independently. The original outcome underwent statistical pooling by using Review Manager 5. Seven studies were included in the systematic review, out of which, five studies were statistically pooled in meta-analysis. The value of EARR of maxillary central incisors in the self-ligating bracket group was significantly lower than that in the conventional bracket group (SMD -0.31; 95% CI: -0.60--0.01). No significant differences in other incisors were observed between self-ligating and conventional brackets. Current evidences suggest self-ligating brackets do not outperform conventional brackets in reducing the EARR in maxillary lateral incisors, mandible central incisors and mandible lateral incisors. However, self-ligating brackets appear to have an advantage in protecting maxillary central incisor from EARR, which still needs to be confirmed by more high-quality studies.

  17. Cost-effectiveness of liquid-based cytology with or without hybrid-capture II HPV test compared with conventional Pap smears: a study by the French Society of Clinical Cytology.

    PubMed

    Cochand-Priollet, Béatrix; Cartier, Isabelle; de Cremoux, Patricia; Le Galès, Catherine; Ziol, Marianne; Molinié, Vincent; Petitjean, Alain; Dosda, Anne; Merea, Estelle; Biaggi, Annonciade; Gouget, Isabelle; Arkwright, Sylviane; Vacher-Lavenu, Marie-Cécile; Vielh, Philippe; Coste, Joël

    2005-11-01

    Many articles concerning conventional Pap smears, ThinPrep liquid-based cytology (LBC) and Hybrid-Capture II HPV test (HC II) have been published. This study, carried out by the French Society of Clinical Cytology, may be conspicuous for several reasons: it was financially independent; it compared the efficiency of the conventional Pap smear and LBC, of the conventional Pap smear and HC II, and included an economic study based on real costs; for all the women, a "gold standard" reference method, colposcopy, was available and biopsies were performed whenever a lesion was detected; The conventional Pap smear, the LBC (split-sample technique), the colposcopy, and the biopsies were done at the same time. This study included 2,585 women shared into two groups: a group A of a high-risk population, a group B of a screening population. The statistical analysis of the results showed that conventional Pap smears consistently had superior or equivalent sensitivity and specificity than LBC for the lesions at threshold CIN-I (Cervical Intraepithelial Neoplasia) or CIN-II or higher. It underlined the low specificity of the HC II. Finally, the LBC mean cost was never covered by the Social Security tariff.

  18. Effects of conventional ozonation and electro-peroxone pretreatment of surface water on disinfection by-product formation during subsequent chlorination.

    PubMed

    Mao, Yuqin; Guo, Di; Yao, Weikun; Wang, Xiaomao; Yang, Hongwei; Xie, Yuefeng F; Komarneni, Sridhar; Yu, Gang; Wang, Yujue

    2018-03-01

    The electro-peroxone (E-peroxone) process is an emerging ozone-based electrochemical advanced oxidation process that combines conventional ozonation with in-situ cathodic hydrogen peroxide (H 2 O 2 ) production for oxidative water treatment. In this study, the effects of the E-peroxone pretreatment on disinfection by-product (DBP) formation from chlorination of a synthetic surface water were investigated and compared to conventional ozonation. Results show that due to the enhanced transformation of ozone (O 3 ) to hydroxyl radicals (OH) by electro-generated H 2 O 2 , the E-peroxone process considerably enhanced dissolved organic carbon (DOC) abatement and significantly reduced bromate (BrO 3 - ) formation compared to conventional ozonation. However, natural organic matter (NOM) with high UV 254 absorbance, which is the major precursors of chlorination DBPs, was less efficiently abated during the E-peroxone process than conventional ozonation. Consequently, while both conventional ozonation and the E-peroxone process substantially reduced the formation of DBPs (trihalomethanes and haloacetic acids) during post-chlorination, higher DBP concentrations were generally observed during chlorination of the E-peroxone pretreated waters than conventional ozonation treated. In addition, because of conventional ozonation or the E-peroxone treatment, DBPs formed during post-chlorination shifted to more brominated species. The overall yields of brominated DBPs exhibited strong correlations with the bromide concentrations in water. Therefore, while the E-peroxone process can effectively suppress bromide transformation to bromate, it may lead to higher formation of brominated DBPs during post-chlorination compared to conventional ozonation. These results suggest that the E-peroxone process can lead to different DBP formation and speciation during water treatment trains compared to conventional ozonation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Echocardiography-based hemodynamic management of left ventricular diastolic dysfunction: a feasibility and safety study.

    PubMed

    Shillcutt, Sasha K; Montzingo, Candice R; Agrawal, Ankit; Khaleel, Maseeha S; Therrien, Stacey L; Thomas, Walker R; Porter, Thomas R; Brakke, Tara R

    2014-11-01

    Patients with left ventricular diastolic dysfunction (LVDD) are at increased risk of postoperative adverse events. The primary aim of this study was to evaluate the safety and feasibility of using echocardiography-guided hemodynamic management (EGHEM) during surgery in subjects with LVDD compared to conventional management. The feasibility of using echocardiography to direct a treatment algorithm and clinical outcomes were compared for safety between groups. Subjects were screened for LVDD by preoperative transthoracic echocardiography (TTE) and randomized to the conventional or EGHEM group. Subjects in EGHEM received hemodynamic management based on left ventricular filling patterns on transesophageal echocardiography (TEE). Primary outcomes measured were the feasibility to obtain TEE images and follow a TEE-based treatment algorithm. Safety outcomes also compared the following clinical differences between groups: length of hospitalization, incidence of atrial fibrillation, congestive heart failure (CHF), myocardial infarction, cerebrovascular accident, transient ischemic attack and renal failure measured 30 days postoperatively. Population consisted of 28 surgical subjects (14 in conventional group and 14 in EGHEM group). Mean subject age was 73.4 ± 6.7 years (36% male) in conventional group and 65.9 ± 14.4 years (36% male) in EGHEM group. Procedures included orthopedic (conventional = 29%, EGHEM 36%), general (conventional = 50%, EGHEM = 36%), vascular (conventional = 7%, EGHEM = 21%), and thoracic (conventional = 14%, EGHEM = 7%). There was no statistically significant difference in adverse clinical events between the 2 groups. The EGHEM group had less CHF, atrial fibrillation, and shorter length of stay. Echocardiography-guided hemodynamic management of patients with LVDD during surgery is feasible and may be a safe alternative to conventional management. © 2014, Wiley Periodicals, Inc.

  20. Comparison of frictional resistance among conventional, active and passive selfligating brackets with different combinations of arch wires: a finite elements study.

    PubMed

    Gómez, Sandra L; Montoya, Yesid; Garcia, Nora L; Virgen, Ana L; Botero, Javier E

    2016-09-01

    The aim of this study was to compare frictional resistance among conventional, passive and active selfligating brackets using Finite Elements Analysis (FEA). Seventynine (79) slide tests were performed by combining an upper first bicuspid conventional bracket, 0.018" stainless steel wires and 0.010" ligature by means of an INSTRON 3345 load system to obtain average maximum static frictional resistance (MSFR). This value was compared to the FR (frictional resistance) obtained by simulation of a slide of the same combination by FEA following conventional bracket modeling by means of Computer Aided Design (CAD). Once the FEA was validated, bracket CADs were designed (upper right first bicuspid conventional, active and passive selfligating bracket) and bracket properties calculated. MSFR was compared among conventional, active and passive selfligating brackets with different alloys and archwire cross sections such as 0.018", 0.019" x 0.025"and 0.020" x 0.020". Passive selfligating brackets had the lowest MSFR, followed by conventional brackets and active selfligating brackets. In conventional brackets, a 0.018" archwire produced a linear pattern of stress with maximum concentration at the center. Conversely, stress in 0.020 x 0.020" and 0.019 x 0.025" archwires was distributed across the width of the slot. The highest normal forces were 1.53 N for the 0.018" archwire, 4.85 N for the 0.020 x 0.020" archwire and 8.18 N for the 0.019 x 0.025" archwire. Passive selfligating brackets presented less frictional resistance than conventional and active selfligating brackets. Regardless of bracket type, greater contact area between the slot and the archwire and the spring clip increased frictional resistance. Sociedad Argentina de Pediatría.

  1. Comparison of performance of shell-and-tube heat exchangers with conventional segmental baffles and continuous helical baffle

    NASA Astrophysics Data System (ADS)

    Ahmed, Asif; Ferdous, Imam Ul.; Saha, Sumon

    2017-06-01

    In the present study, three-dimensional numerical simulation of two shell-and-tube heat exchangers (STHXs) with conventional segmental baffles (STHXsSB) and continuous helical baffle (STHXsHB) is carried out and a comparative study is performed based on the simulation results. Both of the STHXs contain 37 tubes inside a 500 mm long and 200 mm diameter shell and mass flow rate of shell-side fluid is varied from 0.5 kg/s to 2 kg/s. At first, physical and mathematical models are developed and numerically simulated using finite element method (FEM). For the validation of the computational model, shell-side average nusselt number (Nus) is calculated from the simulation results and compared with the available experimental results. The comparative study shows that STHXsHB has 72-127% higher heat transfer coefficient per unit pressure drop compared to the conventional STHXsSB for the same shell-side mass flow rate. Moreover, STHXsHB has 59-63% lower shell-side pressure drop than STHXsSB.

  2. VOLATILE CONSTITUENTS OF GINGER OIL PREPARED ACCORDING TO IRANIAN TRADITIONAL MEDICINE AND CONVENTIONAL METHOD: A COMPARATIVE STUDY.

    PubMed

    Shirooye, Pantea; Mokaberinejad, Roshanak; Ara, Leila; Hamzeloo-Moghadam, Maryam

    2016-01-01

    Herbal medicines formulated as oils were believed to possess more powerful effects than their original plants in Iranian Traditional Medicine (ITM). One of the popular oils suggested for treatment of various indications was ginger oil. In the present study, to suggest a more convenient method of oil preparation (compared to the traditional method), ginger oil has been prepared according to both the traditional and conventional maceration methods and the volatile oil constituents have been compared. Ginger oil was obtained in sesame oil according to both the traditional way and the conventional (maceration) methods. The volatile oil of dried ginger and both oils were obtained by hydro-distillation and analyzed by gas chromatography/mass spectroscopy. Fifty five, fifty nine and fifty one components consisting 94 %, 94 % and 98 % of the total compounds were identified in the volatile oil of ginger, traditional and conventional oils, respectively. The most dominant compounds of the traditional and conventional oils were almost similar; however they were different from ginger essential oil which has also been to possess limited amounts of anti-inflammatory components. It was concluded that ginger oil could be prepared through maceration method and used for indications mentioned in ITM.

  3. Is minimal access spine surgery more cost-effective than conventional spine surgery?

    PubMed

    Lubelski, Daniel; Mihalovich, Kathryn E; Skelly, Andrea C; Fehlings, Michael G; Harrop, James S; Mummaneni, Praveen V; Wang, Michael Y; Steinmetz, Michael P

    2014-10-15

    Systematic review. To summarize and critically review the economic literature evaluating the cost-effectiveness of minimal access surgery (MAS) compared with conventional open procedures for the cervical and lumbar spine. MAS techniques may improve perioperative parameters (length of hospital stay and extent of blood loss) compared with conventional open approaches. However, some have questioned the clinical efficacy of these differences and the associated cost-effectiveness implications. When considering the long-term outcomes, there seem to be no significant differences between MAS and open surgery. PubMed, EMBASE, the Cochrane Collaboration database, University of York, Centre for Reviews and Dissemination (NHS-EED and HTA), and the Tufts CEA Registry were reviewed to identify full economic studies comparing MAS with open techniques prior to December 24, 2013, based on the key questions established a priori. Only economic studies that evaluated and synthesized the costs and consequences of MAS compared with conventional open procedures (i.e., cost-minimization, cost-benefit, cost-effectiveness, or cost-utility) were considered for inclusion. Full text of the articles meeting inclusion criteria were reviewed by 2 independent investigators to obtain the final collection of included studies. The Quality of Health Economic Studies instrument was scored by 2 independent reviewers to provide an initial basis for critical appraisal of included economic studies. The search strategy yielded 198 potentially relevant citations, and 6 studies met the inclusion criteria, evaluating the costs and consequences of MAS versus conventional open procedures performed for the lumbar spine; no studies for the cervical spine met the inclusion criteria. Studies compared MAS tubular discectomy with conventional microdiscectomy, minimal access transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion, and multilevel hemilaminectomy via MAS versus open approach. Overall, the included cost-effectiveness studies generally supported no significant differences between open surgery and MAS lumbar approaches. However, these conclusions are preliminary because there was a paucity of high-quality evidence. Much of the evidence lacked details on methodology for modeling, related assumptions, justification of economic model chosen, and sources and types of included costs and consequences. The follow-up periods were highly variable, indirect costs were not frequently analyzed or reported, and many of the studies were conducted by a single group, thereby limiting generalizability. Prospective studies are needed to define differences and optimal treatment algorithms. 3.

  4. Nanosize Fe x O y @SBA-3: A Comparative Study Between Conventional and Microwave Assisted Synthesis.

    PubMed

    Barik, Sunita; Badamali, Sushanta K; Sahoo, Sagarika; Behera, Nandakishor; Dapurkar, Sudhir E

    2018-01-01

    The present study is focussed on development of highly dispersed nanosize iron oxide (FexOy) particles within the uniform mesopore channels of SBA-3. Herein we report a comparative study between conventional incipient wetness and microwave assisted synthesis routes adopted to devise nanoparticles. The developed materials are characterised by following X-ray diffraction, high resolution transmission electron microscopy, proton induced X-ray emission, diffuse reflectance UV-visible spectroscopy, thermogravimetry and Fourier transform infrared spectroscopy. Mesoporous siliceous SBA-3 was prepared at room temperature to obtain samples with good crystallinity and ordered pore structure. Pore channels of SBA-3 were used as nanoreactor for developing iron oxide nanoparticles. Iron oxide nanoparticles developed under microwave activation showed uniform distribution within the SBA-3 structure along with retaining the orderness of the pore architecture. On the contrary, iron oxides developed under incipient wetness method followed by conventional heating resulted in agglomeration of nanoparticles along with significant loss in SBA-3 pore structure. Proton induced X-ray emission studies revealed the extremely high purity of the samples and almost thrice higher amount of iron oxide particles are encapsulated within the host by microwave assisted preparation as compared to incipient/conventional heating method.

  5. The Misgav Ladach method: a step forward in the operative technique of caesarean section.

    PubMed

    Poonam; Banerjee, B; Singh, S N; Raina, A

    2006-01-01

    Caesarean delivery remains the most common intraperitoneal surgical procedure in obstetric and gynaecologic practice. Since time immemorial there have been countless efforts to improve the technique of caesarean section. One such innovative breakthrough technique is the Misgav Ladach method of caesarean of section. The objective of this trial was to compare the intraoperative and short-term postoperative outcomes between the conventional and the Misgav-Ladach technique for caesarean section. The randomized prospective comparative study was carried out in the department of Obstetrics and Gynaecology, B.P Koirala Institute of Health Sciences, Dharan Nepal. Four hundred patients were randomized to either Misgav Ladach or the Conventional method of caesarean section. Only term pregnancies with singleton foetuses' were included whereas pregnancies with previous caesarean section were excluded from the study. The study period was from September 2001 to September 2004. There was not much difference in the demographic variables between the two groups. The age of the patients ranged between 18-40 years. The mean age of patients in Misgav Ladach and conventional group was 24.5 and 23.6 years respectively. Foetal distress was the commonest indication for caesarean section followed by non progress of labour. The mean incision to delivery interval, operating time and blood loss in the Misgav Ladach group was 1 minute 30 seconds, 16 minutes and 35 0ml as compared to 3 minutes, 28 minutes and 600 ml in the conventional group respectively. 3.5%of patients in the Misgav Ladach group showed febrile morbidity as compared to 7% in the conventional group. 19% from conventional group and only 4%from Misgav Ladach group required added analgesia. Almost equal number of patients (10-12) in each group experienced significant headache.).0.1%in the Misgav group and 5% in the Conventional group required post operative blood transfusion. Four patients from the conventional group had their wound gaped. The number of neonates requiring intensive care was sixteen (8% ) in the conventional group and 3 (1.5%) in the Misgav group.6.5% from conventional group and 2% from Misgav Ladach group required maternal intensive care admissions. Misgav-Ladach technique has been be associated with shorter operative time, quicker recovery, and lesser need for postoperative medications, when compared with traditional caesarean section. It has also been shown to be more cost-effective. A further advantage of the technique may be the shorter time taken for the delivery of the child.

  6. Comparison of the financial performance of Islamic and conventional bank in Malaysia during and after economic crisis

    NASA Astrophysics Data System (ADS)

    Kadir, Norhidayah A.; Jaffar, Aidatullaini; Abdullah, Nur Lina; Harun, Nurzalina

    2013-09-01

    This paper is a continuation of our former work. In this paper, we compare the financial performance of the two banking systems that exist in Malaysia over two periods of time, during economic crisis (1997-1999) and after economic crisis (2001-2003). In order to see the conventional as well as Islamic bank's performance over these two periods of time, the study uses 10 financial ratios which are broadly categorized into 4 groups: (a) profitability ratios; (b) liquidity ratios; (c) risk and solvency ratios; and (d) efficiency ratios. Next, the study used T-test in determining the significance of the differential performance of the two banks over two periods of time. By using inter-bank comparison, the study found that, conventional bank has better performance, efficient, more profitable and has greater risk as compared to Islamic bank. However, in terms of utilizing asset, Islamic bank is better than conventional bank. As an overall, conventional bank is better in much aspect due to the longer history and experience in the industry than Islamic bank that start their operation in 1983.

  7. Durability of styrene-butadiene latex modified concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaker, F.A.; El-Dieb, A.S.; Reda, M.M.

    1997-05-01

    The durability of reinforced concrete structures represents a major concern to many investigators. The use of latex modified concrete (LMC) in construction has urged researchers to review and investigate its different properties. This study is part of a comprehensive investigation carried on the use of polymers in concrete. The main objective of this study to investigate and evaluate the main durability aspects of Styrene-Butadiene latex modified concrete (LMC) compared to those of conventional concrete. Also, the main microstructural characteristics of LMC were studied using a Scanning Electron Microscope (SEM). The SEM investigation of the LMC showed major differences in itsmore » microstructure compared to that of the conventional concrete. The LMC proved to be superior in its durability compared to the durability of conventional concrete especially its water tightness (measured by water penetration, absorption, and sorptivity tests), abrasion, corrosion, and sulphate resistance.« less

  8. Antireflux Versus Conventional Plastic Stent in Malignant Biliary Obstruction: A Prospective Randomized Study.

    PubMed

    Vihervaara, Hanna; Grönroos, Juha M; Hurme, Saija; Gullichsen, Risto; Salminen, Paulina

    2017-01-01

    Endoscopic stents are used to relieve obstructive jaundice. The purpose of this prospective randomized study was to compare the patency of antireflux and conventional plastic biliary stent in relieving distal malignant biliary obstruction. All jaundiced patients admitted to hospital with suspected unresectable malignant distal biliary stricture between October 2009 and September 2010 were evaluated for the study. Eligible patients were randomized either to antireflux or conventional plastic stent arms. The primary endpoint was stent patency and the follow-up was continued either until the stent was occluded or until 6 months after the stent placement. At an interim analysis, antireflux stents (ARSs; n = 6) had a significantly shorter median patency of 34 (8-49) days compared with the conventional stent (n = 7) patency of 167 (38-214) days (P = .0003). Based on these results, the study was terminated due to ethical concerns. According to these results, the use of this ARS is not recommended.

  9. Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

    PubMed

    Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover

    2012-06-01

    The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.

  10. Seamless Phase IIa/IIb and enhanced dose-finding adaptive design.

    PubMed

    Yuan, Jiacheng; Pang, Herbert; Tong, Tiejun; Xi, Dong; Guo, Wenzhao; Mesenbrink, Peter

    2016-01-01

    In drug development, when the drug class has a relatively well-defined path to regulatory approval and the enrollment is slow with certain patient populations, one may want to consider combining studies of different phases. This article considers combining a proof of concept (POC) study and a dose-finding (DF) study with a control treatment. Conventional DF study designs sometimes are not efficient, or do not have a high probability to find the optimal dose(s) for Phase III trials. This article seeks more efficient DF strategies that allow the economical testing of more doses. Hypothetical examples are simulated to compare the proposed adaptive design vs. the conventional design based on different models of the overall quantitative representation of efficacy, safety, and tolerability. The results show that the proposed adaptive design tests more active doses with higher power and comparable or smaller sample size in a shorter overall study duration for POC and DF, compared with a conventional design.

  11. Factorial design studies of antiretroviral drug-loaded stealth liposomal injectable: PEGylation, lyophilization and pharmacokinetic studies

    NASA Astrophysics Data System (ADS)

    Sudhakar, Beeravelli; Krishna, Mylangam Chaitanya; Murthy, Kolapalli Venkata Ramana

    2016-01-01

    The aim of the present study was to formulate and evaluate the ritonavir-loaded stealth liposomes by using 32 factorial design and intended to delivered by parenteral delivery. Liposomes were prepared by ethanol injection method using 32 factorial designs and characterized for various physicochemical parameters such as drug content, size, zeta potential, entrapment efficiency and in vitro drug release. The optimization process was carried out using desirability and overlay plots. The selected formulation was subjected to PEGylation using 10 % PEG-10000 solution. Stealth liposomes were characterized for the above-mentioned parameters along with surface morphology, Fourier transform infrared spectrophotometer, differential scanning calorimeter, stability and in vivo pharmacokinetic studies in rats. Stealth liposomes showed better result compared to conventional liposomes due to effect of PEG-10000. The in vivo studies revealed that stealth liposomes showed better residence time compared to conventional liposomes and pure drug solution. The conventional liposomes and pure drug showed dose-dependent pharmacokinetics, whereas stealth liposomes showed long circulation half-life compared to conventional liposomes and pure ritonavir solution. The results of statistical analysis showed significance difference as the p value is (<0.05) by one-way ANOVA. The result of the present study revealed that stealth liposomes are promising tool in antiretroviral therapy.

  12. The efficacy and safety of drug-eluting balloons for the treatment of in-stent restenosis as compared with drug-eluting stents and with conventional balloon angioplasty

    PubMed Central

    Oh, Pyung Chun; Suh, Soon Yong; Kang, Woong Chol; Lee, Kyounghoon; Han, Seung Hwan; Ahn, Taehoon; Shin, Eak Kyun

    2016-01-01

    Background/Aims: Treatment of coronary in-stent restenosis (ISR) is still associated with a high incidence of recurrence. We aimed to compare the efficacy and safety of drug-eluting balloons (DEB) for the treatment of ISR as compared with conventional balloon angioplasty (BA) and drug-eluting stents (DES). Methods: Between January 2006 and May 2012 a total of 177 patients (188 lesions, 64.1 ± 11.7 years old) who underwent percutaneous coronary intervention for ISR were retrospectively enrolled. Clinical outcomes were compared between patients treated with DEB (n = 58, 32.8%), conventional BA (n = 65, 36.7%), or DES (n = 54, 30.5%). The primary end point was a major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction, and target lesion revascularization(TLR). Results: Baseline characteristics were not different except for a history of previous MI, which was more frequent in patients treated by conventional BA or DES than in patients treated by DEB (40.0% vs. 48.1% vs. 17.2%, respectively, p = 0.002). The total incidences of MACEs were 10.7%, 7.4%, and 15.4% in patients treated by DEB, DES, or conventional BA, respectively (p > 0.05). TLR was more frequent in patients treated by conventional BA than in patients treated by DEB or DES, but this was not statistically significant (10.8% vs. 6.9% vs. 3.7%, p > 0.05 between all group pairs, respectively). Conclusions: This study showed that percutaneous coronary intervention using DEB might be a feasible alternative to conventional BA or DES implantation for treatment of coronary ISR. Further large-scaled, randomized study assessing long-term clinical and angiographic outcomes will be needed. PMID:26951915

  13. Robotic versus laparoscopic proctectomy for rectal cancer: a meta-analysis.

    PubMed

    Memon, Sameer; Heriot, Alexander G; Murphy, Declan G; Bressel, Mathias; Lynch, A Craig

    2012-07-01

    Robot-assisted laparoscopic surgery is being performed more frequently for the minimally invasive management of rectal cancer. The objective of this meta-analysis was to compare the clinical and oncologic safety and efficacy of robot-assisted versus conventional laparoscopic surgery. A search of the Medline and Embase databases was performed for studies that compared clinical or oncologic outcomes of conventional laparoscopic proctectomy with robot-assisted laparoscopic proctectomy for rectal cancer. The methodological quality of the selected studies was critically assessed to identify studies suitable for inclusion. Meta-analysis was performed by a random effects model and analyzed by Review Manager. Clinical outcomes evaluated were conversion rates, operation times, length of hospital stay, and complications. Oncologic outcomes evaluated were circumferential margin status, number of lymph nodes collected, and distal resection margin lengths. Eight comparative studies were assessed for quality, and seven studies were included in the meta-analysis. Two studies were matched case-control studies, and five were unmatched. A total of 353 robot-assisted laparoscopic surgery proctectomy cases and 401 conventional laparoscopic surgery proctectomy cases were analyzed. Robotic surgery was associated with a significantly lower conversion rate (P=0.03; 95% confidence interval 1-12). There was no difference in complications, circumferential margin involvement, distal resection margin, lymph node yield, or hospital stay (P=NS). Robot-assisted surgery decreased the conversion rate compared to conventional laparoscopic surgery. Other clinical outcomes and oncologic outcomes were equivalent. The benefits of robotic rectal cancer surgery may differ between population groups.

  14. The dependence of Islamic and conventional stocks: A copula approach

    NASA Astrophysics Data System (ADS)

    Razak, Ruzanna Ab; Ismail, Noriszura

    2015-09-01

    Recent studies have found that Islamic stocks are dependent on conventional stocks and they appear to be more risky. In Asia, particularly in Islamic countries, research on dependence involving Islamic and non-Islamic stock markets is limited. The objective of this study is to investigate the dependence between financial times stock exchange Hijrah Shariah index and conventional stocks (EMAS and KLCI indices). Using the copula approach and a time series model for each marginal distribution function, the copula parameters were estimated. The Elliptical copula was selected to present the dependence structure of each pairing of the Islamic stock and conventional stock. Specifically, the Islamic versus conventional stocks (Shariah-EMAS and Shariah-KLCI) had lower dependence compared to conventional versus conventional stocks (EMAS-KLCI). These findings suggest that the occurrence of shocks in a conventional stock will not have strong impact on the Islamic stock.

  15. A Comparative Study of Phosphoric Acid-doped m-PBI Membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, Kelly A; More, Karren Leslie; Payzant, E Andrew

    2014-01-01

    Phosphoric acid (PA)-doped m-polybenzimidazole (PBI) membranes used in high temperature fuel cells and hydrogen pumps were prepared by a conventional imbibing process and a sol-gel fabrication process. A comparative study was conducted to investigate the critical properties of PA doping levels, ionic conductivities, mechanical properties, and molecular ordering. This systematic study found that sol-gel PA-doped m-PBI membranes were able to absorb higher acid doping levels and to achieve higher ionic conductivities than conventionally imbibed membranes when treated in an equivalent manner. Even at similar acid loadings, the sol-gel membranes exhibited higher ionic conductivities. Heat treatment of conventionally imbibed membranes withmore » 29wt% solids caused a significant reduction in mechanical properties; conversely, sol-gel membranes exhibited an enhancement in mechanical properties. From X-ray structural studies and atomistic simulations, both conventionally imbibed and sol-gel membranes exhibited d-spacings of 3.5 and 4.6 , which were tentatively attributed to parallel ring stacking and staggered side-to-side packing, respectively, of the imidazole rings in these aromatic hetercyclic polymers. An anisotropic staggered side-to-side chain packing present in the conventional membranes may be root to the reduction in mechanical properties.« less

  16. Properties of Concrete partially replaced with Coconut Shell as Coarse aggregate and Steel fibres in addition to its Concrete volume

    NASA Astrophysics Data System (ADS)

    Kalyana Chakravarthy, P. R.; Janani, R.; Ilango, T.; Dharani, K.

    2017-03-01

    Cement is a binder material with various composition of Concrete but instantly it posses low tensile strength. The study deals with mechanical properties of that optimized fiber in comparison with conventional and coconut shell concrete. The accumulation of fibers arbitrarily dispersed in the composition increases the resistance to cracking, deflection and other serviceability conditions substantially. The steel fiber in extra is one of the revision in coconut shell concrete and the outcome of steel fiber in coconut shell concrete was to investigate and compare with the conventional concrete. For the given range of steel fibe from 0.5 to 2.0%, 12 beams and 36 cylindrical specimens were cast and tested to find the mechanical properties like flexural strength, split tensile, impact resistance and the modulus of elasticity of both conventional and coconut shell concrete has been studied and the test consequences are compared with the control concrete and coconut shell concrete for M25 Grade. It is fulfilled that, the steel fibers used in this venture has shown significant development in all the properties of conventional and coconut shell concrete while compared to controlled conventional and coconut shell concrete like, Flexural strength by 6.67 % for 1.0 % of steel fiber in conventional concrete and by 5.87 % for 1.5 % of steel fiber in coconut shell concrete.

  17. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    PubMed

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  18. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability.

    PubMed

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-09-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee.

  19. Measuring Teacher Classroom Management Skills: A Comparative Analysis of Distance Trained and Conventional Trained Teachers

    ERIC Educational Resources Information Center

    Henaku, Christina Bampo; Pobbi, Michael Asamani

    2017-01-01

    Many researchers and educationist remain skeptical about the effectiveness of distance learning program and have termed it as second to the conventional training method. This perception is largely due to several challenges which exist within the management of distance learning program across the country. The general aim of the study is compare the…

  20. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment.

    PubMed

    Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F

    2009-12-01

    New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.

  1. Influence of nanophase titania topography on bacterial attachment and metabolism

    PubMed Central

    Park, Margaret R; Banks, Michelle K; Applegate, Bruce; Webster, Thomas J

    2008-01-01

    Surfaces with nanophase compared to conventional (or nanometer smooth) topographies are known to have different properties of area, charge, and reactivity. Previously published research indicates that the attachment of certain bacteria (such as Pseudomonas fluorescens 5RL) is higher on surfaces with nanophase compared to conventional topographies, however, their effect on bacterial metabolism is unclear. Results presented here show that the adhesion of Pseudomonas fluorescens 5RL and Pseudomonas putida TVA8 was higher on nanophase than conventional titania. Importantly, in terms of metabolism, bacteria attached to the nanophase surfaces had higher bioluminescence rates than on the conventional surfaces under all nutrient conditions. Thus, the results from this study show greater select bacterial metabolism on nanometer than conventional topographies, critical results with strong consequences for the design of improved biosensors for bacteria detection. PMID:19337418

  2. Clinical effect of individualized parenteral nutrition vs conventional method in patients undergoing autologous hematopoietic SCT.

    PubMed

    Tavakoli-Ardakani, M; Neman, B; Mehdizadeh, M; Hajifathali, A; Salamzadeh, J; Tabarraee, M

    2013-07-01

    Malnutrition in patients undergoing hematopoietic SCT is known as a risk factor for adverse effects and is directly or indirectly responsible for excess mortality and morbidity. We designed the present study to evaluate the effects of individualized parenteral nutrition (PN) and compare the present method to the conventional PN. Individualized PN based on the Harris-Benedict equation was administered to 30 patients after hematopoietic SCT and was compared with an age, gender and disease matched group of patients who underwent hematopoietic SCT with conventional PN. These two groups were compared on clinical, hematological, nutritional outcomes. Comparing duration of hospital stay (P value<0.0001), infection (P value = 0.01), time to platelet engraftment (P value = 0.02), units of packed cell transfusion (P value = 0.006) and decrease in body weight (P value = 0.004) showed significant differences between the two groups. In conclusion, the use of individualized PN seems more beneficial than conventional PN.

  3. Stability and Curving Performance of Conventional and Advanced Rail Transit Vehicles

    DOT National Transportation Integrated Search

    1984-01-01

    Analytical studies are presented which compare the curving performance and speed capability of conventional rail transit trucks with self steering (cross-braced) and forced steering (linkages between carbody and wheelsets) radial trucks. Truck curvin...

  4. Demystifying the Enigma of Smoking – An Observational Comparative Study on Tobacco Smoking

    PubMed Central

    Nallakunta, Rajesh; Reddy, Sudhakara Reddy; Chennoju, Sai Kiran

    2016-01-01

    Introduction Smoking is a hazardous habit which causes definite changes in the oral cavity, consequently there exist changes in the mucosa when subjected to smoking. Palatal mucosa is first to be affected. The present study determines the palatal status in reverse smokers and conventional smokers. Aim To study and compare the clinical, cytological and histopathological changes in palatal mucosa among reverse and conventional smokers. Materials and Methods Study sample was categorized into two groups. Group 1 comprised of 20 subjects with the habit of reverse smoking and Group 2 comprised of 20 subjects with the habit of conventional smoking. Initially, clinical appearance of the palatal mucosa was recorded, followed by a cytological smear and biopsy of the involved area among all the subjects. The findings were studied clinically, the specimens were analysed cytologically and histopathologically, and compared among the two groups. Results The severity of clinical changes of the palatal mucosa among reverse smokers was statistically significant when compared to those of conventional smokers. There was no statistically significant difference observed in cytological staging between the groups with a p-value of 0.35. The histopathological changes in both the groups showed a significant difference with a p-value of 0.02. A significant positive correlation was observed between the clinical appearance, and cytological, histopathological changes. Conclusion Profound clinically aggressive changes were observed in group I compared to group II. Severity of dysplastic changes have been detected in few subjects through histopathological examination irrespective of no prominent clinical and cytological changes observed among the two groups. PMID:27190962

  5. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    PubMed

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; P<.001). The intraoral mask resulted in greater received minute volume received compared with conventional cuffed face mask during ventilation with a 1-handed mask seal in a cadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  6. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness.

    PubMed

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. The results of the t -test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness.

  7. Comparative study of long-term outcomes of accelerated and conventional collagen crosslinking for progressive keratoconus.

    PubMed

    Males, J J; Viswanathan, D

    2018-01-01

    PurposeTo compare the long-term outcomes of accelerated corneal collagen crosslinking (CXL) to conventional CXL for progressive keratoconus.Patients and methodsComparative clinical study of consecutive progressive keratoconic eyes that underwent either accelerated CXL (9 mW/cm 2 ultraviolet A (UVA) light irradiance for 10 min) or conventional CXL (3 mW/cm 2 UVA light irradiance for 30 min). Eyes with minimum 12 months' follow-up were included. Post-procedure changes in keratometry readings (Flat meridian: K1; steep meridian: K2), central corneal thickness (CCT), best spectacle-corrected visual acuity (BSCVA), and manifest refraction spherical equivalent (MRSE) were analysed.ResultsA total of 42 eyes were included. In all, 21 eyes had accelerated CXL (20.5±5.5 months' follow-up) and 21 eyes had conventional CXL group (20.2±5.6 months' follow-up). In the accelerated CXL group, a significant reduction in K2 (P=0.02), however no significant change in K1 (P=0.35) and CCT (P=0.62) was noted. In the conventional CXL group, a significant reduction was seen in K1 (P=0.01) and K2 (P=0.04), but not in CCT (P=0.95). Although both groups exhibited significant reductions in K2 readings, no noteworthy differences were noted between them (P=0.36). Improvements in BSCVA (accelerated CXL; P=0.22 and conventional CXL; P=0.20) and MRSE (accelerated CXL; P=0.97 and conventional CXL; P=0.54) were noted, however were not significant in either group.ConclusionAccelerated and conventional CXL appear to be effective procedures for stabilising progressive keratoconus in the long-term.

  8. Blood culture bottles are superior to conventional media for vitreous culture.

    PubMed

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P < 0.00001) and an odds ratio of 3.47 (95% confidence interval 1.92, 6.63). A combination of blood culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  9. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A

    2005-01-01

    To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.

  10. Effect of milk type and processing on iodine concentration of organic and conventional winter milk at retail: implications for nutrition.

    PubMed

    Payling, Laura M; Juniper, Darren T; Drake, Chris; Rymer, Caroline; Givens, D Ian

    2015-07-01

    Milk is the largest source of iodine in UK diets and an earlier study showed that organic summer milk had significantly lower iodine concentration than conventional milk. There are no comparable studies with winter milk or the effect of milk fat class or heat processing method. Two retail studies with winter milk are reported. Study 1 showed no effect of fat class but organic milk was 32.2% lower in iodine than conventional milk (404 vs. 595 μg/L; P<0.001). Study 2 found no difference between conventional and Channel Island milk but organic milk contained 35.5% less iodine than conventional milk (474 vs. 306 μg/L; P<0.001). UHT and branded organic milk also had lower iodine concentrations than conventional milk (331 μg/L; P<0.001 and 268 μg/L: P<0.0001 respectively). The results indicate that replacement of conventional milk by organic or UHT milk will increase the risk of sub-optimal iodine status especially for pregnant/lactating women. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study

    DTIC Science & Technology

    2011-01-01

    Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study Samuel A. Spear1 and James V. Crawford2 1 48th Medical Group, ENT...cited. Objective. To visually compare the Nitinol “smart” stapes prosthesis to conventional manual crimping stapes pistons in temporal bone cadaver...answer questions about each stapes piston. The answers to the survey were then recorded for analysis. Results. 8 of 9 Nitinol pistons were described as

  12. Unsedated transnasal small-caliber esophagogastroduodenoscopy in elderly and bedridden patients.

    PubMed

    Yuki, Mika; Amano, Yuji; Komazawa, Yoshinori; Fukuhara, Hiroyuki; Shizuku, Toshihiro; Yamamoto, Shun; Kinoshita, Yoshikazu

    2009-11-28

    To evaluate the safety of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) for elderly and critically ill bedridden patients. One prospective randomized comparative study and one crossover comparative study between transnasal small-caliber EGD and transoral conventional EGD was done (Study 1). For the comparative study, we enrolled 240 elderly patients aged > 65 years old. For the crossover analysis, we enrolled 30 bedridden patients with percutaneous endoscopic gastrostomy (PEG) (Study 2). We evaluated cardiopulmonary effects by measuring arterial oxygen saturation (SpO(2)) and calculating the rate-pressure product (RPP) (pulse rate x systolic blood pressure/100) at baseline, 2 and 5 min after endoscopic intubation in Study 1. To assess the risk for endoscopy-related aspiration pneumonia during EGD, we also measured blood leukocyte counts and serum C-reactive protein (CRP) levels before and 3 d after EGD in Study 2. In Study 1, we observed significant decreases in SpO(2) during conventional transoral EGD, but not during transnasal small-caliber EGD (0.24% vs -0.24% after 2 min, and 0.18% vs -0.29% after 5 min, P = 0.034, P = 0.044). Significant differences of the RPP were not found between conventional transoral and transnasal small-caliber EGD. In Study 2, crossover analysis showed statistically significant increases of the RPP at 2 min after intubation and the end of endoscopy (26.8 and 34.6 vs 3.1 and 15.2, P = 0.044, P = 0.046), and decreases of SpO(2) (-0.8% vs -0.1%, P = 0.042) during EGD with transoral conventional in comparison with transnasal small-caliber endoscopy. Thus, for bedridden patients with PEG feeding, who were examined in the supine position, transoral conventional EGD more severely suppressed cardiopulmonary function than transnasal small-caliber EGD. There were also significant increases in the markers of inflammation, blood leukocyte counts and serum CRP values, in bedridden patients after transoral conventional EGD, but not after transnasal small-caliber EGD performed with the patient in the supine position. Leukocyte count increased from 6053 +/- 1975/L to 6900 +/- 3392/L (P = 0.0008) and CRP values increased from 0.93 +/- 0.24 to 2.49 +/- 0.91 mg/dL (P = 0.0005) at 3 d after transoral conventional EGD. Aspiration pneumonia, possibly caused by the endoscopic examination, was found subsequently in two of 30 patients after transoral conventional EGD. Transnasal small-caliber EGD is a safer method than transoral conventional EGD in critically ill, bedridden patients who are undergoing PEG feeding.

  13. Unsedated transnasal small-caliber esophagogastroduodenoscopy in elderly and bedridden patients

    PubMed Central

    Yuki, Mika; Amano, Yuji; Komazawa, Yoshinori; Fukuhara, Hiroyuki; Shizuku, Toshihiro; Yamamoto, Shun; Kinoshita, Yoshikazu

    2009-01-01

    AIM: To evaluate the safety of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) for elderly and critically ill bedridden patients. METHODS: One prospective randomized comparative study and one crossover comparative study between transnasal small-caliber EGD and transoral conventional EGD was done (Study 1). For the comparative study, we enrolled 240 elderly patients aged > 65 years old. For the crossover analysis, we enrolled 30 bedridden patients with percutaneous endoscopic gastrostomy (PEG) (Study 2). We evaluated cardiopulmonary effects by measuring arterial oxygen saturation (SpO2) and calculating the rate-pressure product (RPP) (pulse rate × systolic blood pressure/100) at baseline, 2 and 5 min after endoscopic intubation in Study 1. To assess the risk for endoscopy-related aspiration pneumonia during EGD, we also measured blood leukocyte counts and serum C-reactive protein (CRP) levels before and 3 d after EGD in Study 2. RESULTS: In Study 1, we observed significant decreases in SpO2 during conventional transoral EGD, but not during transnasal small-caliber EGD (0.24% vs -0.24% after 2 min, and 0.18% vs -0.29% after 5 min, P = 0.034, P = 0.044). Significant differences of the RPP were not found between conventional transoral and transnasal small-caliber EGD. In Study 2, crossover analysis showed statistically significant increases of the RPP at 2 min after intubation and the end of endoscopy (26.8 and 34.6 vs 3.1 and 15.2, P = 0.044, P = 0.046), and decreases of SpO2 (-0.8% vs -0.1%, P = 0.042) during EGD with transoral conventional in comparison with transnasal small-caliber endoscopy. Thus, for bedridden patients with PEG feeding, who were examined in the supine position, transoral conventional EGD more severely suppressed cardiopulmonary function than transnasal small-caliber EGD. There were also significant increases in the markers of inflammation, blood leukocyte counts and serum CRP values, in bedridden patients after transoral conventional EGD, but not after transnasal small-caliber EGD performed with the patient in the supine position. Leukocyte count increased from 6053 ± 1975/L to 6900 ± 3392/L (P = 0.0008) and CRP values increased from 0.93 ± 0.24 to 2.49 ± 0.91 mg/dL (P = 0.0005) at 3 d after transoral conventional EGD. Aspiration pneumonia, possibly caused by the endoscopic examination, was found subsequently in two of 30 patients after transoral conventional EGD. CONCLUSION: Transnasal small-caliber EGD is a safer method than transoral conventional EGD in critically ill, bedridden patients who are undergoing PEG feeding. PMID:19938199

  14. Comparative Short-Term Clinical Outcomes of Mediastinum Tumor Excision Performed by Conventional VATS and Single-Port VATS: Is It Worthwhile?

    PubMed

    Wu, Ching-Feng; Gonzalez-Rivas, Diego; Wen, Chih-Tsung; Liu, Yun-Hen; Wu, Yi-Cheng; Chao, Yin-Kai; Hsieh, Ming-Ju; Wu, Ching-Yang; Chen, Wei-Hsun

    2015-11-01

    Single-port video-assisted thoracoscopic surgery (VATS) has been widely applied recently. However, there are still only few reports describing its use in mediastinum tumor resection. We present the technique of single-port video-assisted thoracoscopic mediastinum tumor resection and compare it with conventional VATS with regard to short-term outcome.We retrospectively enrolled 105 patients who received mediastinum surgery in Chang Gung Memorial Hospital. Sixteen patients received sternotomy or thoracotomy, 29 patients received single-port VATS, and 60 patients received conventional VATS (3 ports). The operative time, blood loss, postoperation day 1 pain score, discharge day pain score, and postoperative hospital stay were compared. In order to establish a well balanced cohort study, we also use propensity scores match (1:1) to compare the short-term clinical outcome in 2 groups.No operative deaths occurred in this study. Single-port VATS was associated with shorter operative time, lower postoperation day 1 pain score, and shorter postoperation hospital stay in our cohort study (P = 0.001, <0.001, and 0.039), and propensity scores matched cohort study (P = 0.003, <0.001, and <0.001).Single-port VATS for mediastinum tumor appears to be a safe and promising technique with short-term outcome not inferior to conventional VATS in our cohort study. The long-term oncology outcome may require time and more enrolled patients to be further evaluated.

  15. The influence of droplet size on the stability, in vivo digestion, and oral bioavailability of vitamin E emulsions.

    PubMed

    Parthasarathi, S; Muthukumar, S P; Anandharamakrishnan, C

    2016-05-18

    Vitamin E (α-tocopherol) is a nutraceutical compound, which has been shown to possess potent antioxidant and anticancer activity. However, its biological activity may be limited by its poor bioavailability. Colloidal delivery systems have shown wide applications in the food and pharmaceutical industries to deliver lipophilic bioactive compounds. In this study, we have developed conventional and nanoemulsions of vitamin E from food grade ingredients (sunflower oil, saponin, and water) and showed the nanoemulsion formulation increased the oral bioavailability when compared to the conventional emulsion. The mean droplet diameters in the nano and conventional emulsions were 0.277 and 1.285 μm, respectively. The stability of the emulsion formulation after thermal processing, long-term storage at different temperatures, mechanical stress and in plasma was determined. The results showed that the saponin coated nanoemulsion was stable to droplet coalescence during thermal processing (30-90 °C), long-term storage and mechanical stress when compared to the conventional emulsion. The biological fate of the emulsion formulations were studied using male Wistar rats as an animal model. The emulsion droplet stability during passage through the gastrointestinal tract was evaluated by their introduction into rat stomachs. Microscopy was used to investigate the structural changes that occurred during digestion. Both the conventional emulsion and nanoemulsion formulations showed strong evidence of droplet flocculation and coalescence during in vivo digestion. The in vivo oral bioavailability study revealed that vitamin E in a nanoemulsion form showed a 3-fold increase in the AUC when compared to the conventional emulsion. The information reported in this study will facilitate the design of colloidal delivery systems using nanoemulsion formulations.

  16. Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI.

    PubMed

    Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane

    2018-07-01

    To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.

  17. Anti-TNF-A Therapy about Infliximab and Adalimamab for the Effectiveness in Ulcerative Colitis Compared with Conventional Therapy: A Meta-Analysis.

    PubMed

    Zhou, Zheng; Dai, Cong; Liu, Wei-xin

    2015-06-01

    TNF-α has an important role in the pathogenesis of ulcerative colitis (UC). It seems that anti-TNF-α therapy is beneficial in the treatment of UC. The aim was to assess the effectiveness of Infliximab and Adalimamab with UC compared with con- ventional therapy. The Pubmed and Embase databases were searched for studies investigating the efficacy of infliximab and adalimumab on UC. Infliximab had a statistically significant effects in induction of clinical response (RR = 1.67; 95% CI 1.12 to 2.50) of UC compared with conventional therapy, but those had not a statistically significant effects in clinical remission (RR = 1.63; 95% CI 0.84 to 3.18) and reduction of colectomy rate (RR = 0.54; 95% CI 0.26 to 1.12) of UC. And adalimumab had a statistically significant effects in induction of clinical remission (RR =1.82; 95% CI 1.24 to 2.67) and clinical response (RR =1.36; 95% CI 1.13 to 1.64) of UC compared with conventional therapy. Our meta-analyses suggested that Infliximab had a statistically significant effects in induction of clinical response of UC compared with conventional therapy and adalimumab had a statistically significant effects in induction of clinical remission and clinical response of UC compared with conventional therapy.

  18. High-Flow Nasal Cannula versus Conventional Oxygen Therapy in Children with Respiratory Distress.

    PubMed

    Sitthikarnkha, Punthila; Samransamruajkit, Rujipat; Prapphal, Nuanchan; Deerojanawong, Jitladda; Sritippayawan, Suchada

    2018-05-01

    The aim of this study is to determine the clinical efficacy of high-flow nasal cannula (HFNC) therapy compared with conventional oxygen therapy in children presented with respiratory distress. This was a randomized controlled study. Infants and children aged between 1 month to 5 years who were admitted to our tertiary referral center for respiratory distress (July 1, 2014 to March 31, 2015) and met the inclusion criteria were recruited. Infants and children hospitalized with respiratory distress were randomized into two groups of interventions. All clinical data, for example, respiratory score, pulse rate, and respiratory rate were recorded. The results were subsequently analyzed. A total of 98 respiratory distress children were enrolled during the study period. Only 4 children (8.2%) failed in HFNC therapy, compared with 10 children (20.4%) in conventional oxygen therapy group ( P = 0.09). After adjusted for body weight, underlying diseases, and respiratory distress score, there was an 85% reduction in the odds of treatment failure in HFNC therapy group (adjusted odds ratio 0.15, 95% confidence interval 0.03-0.66, P = 0.01). Most children in HFNC therapy group had significant improvement in clinical respiratory score, heart rate, and respiratory rate at 240, 360, and 120 min compared with conventional oxygen therapy ( P = 0.03, 0.04, and 0.03). HFNC therapy revealed a potential clinical advantage in management children hospitalized with respiratory distress compared with conventional respiratory therapy. The early use of HFNC in children with moderate-to-severe respiratory distress may prevent endotracheal tube intubation. TCTR 20170222007.

  19. Enhanced sun protection of nano-sized metal oxide particles over conventional metal oxide particles: an in vitro comparative study.

    PubMed

    Singh, P; Nanda, A

    2014-06-01

    A systematic and detailed study has been designed and conducted, taking into account some of the proposed benefits such as increased efficiency, transparency, unique texture, protection of active ingredient and higher consumer compliance of cosmetics containing nano-sized metal oxides. This study also presents an in vitro method to determine sun protection factor of the investigational sunscreen cream samples containing zinc oxide and titanium dioxide with a varied range of particle size. Finally, a comparative study has been conducted between metal oxide particles, conventional as well as nanoparticles. All the skin cosmetics formulated were thermally stable with a pH ranging from 7.9 to 8.2. Moreover, the fatty acid substance content and residue were found to be analogous to the standard values in each skin cosmetic. The skin cosmetics containing the titanium or zinc oxide nanoparticles were found to have improved spreadability as compared to skin cosmetics containing conventional titanium or zinc oxide particles, respectively. All skin cosmetics were found to have uniform distribution of the particles. The sunscreen creams containing zinc oxide nanoparticles and titanium dioxide nanoparticles were found to have higher in vitro sun protection factor (SPF of 3.65 for ZnO nanoparticles and 4.93 for TiO2 nanoparticles) as compared to that of sunscreen creams containing conventional zinc oxide particles (SPF = 2.90) and conventional titanium dioxide (SPF = 1.29), clearly indicating the effect of reduction in particles size, from micro to nano, on the sun protection factor. Good texture, better spreadability and enhanced in vitro SPF proved the advantageous role of nanoparticles in cosmetics. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  20. Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

    PubMed

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-07-01

    Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding.

  1. Wound healing of osteotomy defects prepared with piezo or conventional surgical instruments: a pilot study in rabbits.

    PubMed

    Ma, Li; Mattheos, Nikos; Sun, Yan; Liu, Xi Ling; Yip Chui, Ying; Lang, Niklaus Peter

    2015-08-01

    The aim of the present study was to evaluate and compare the wound-healing process following osteotomies performed with either conventional rotary burs or piezoelectric surgery in a rabbit model. Two types of osteotomy window defects of the nasal cavities were prepared on the nasal bone of 16 adult New Zealand white rabbits with either a conventional rotary bur or piezo surgery. The defects were covered with a resorbable membrane. Four animals were killed at 1, 2, 3, and 5 weeks after the surgical procedure, respectively. Histological and morphometric evaluations were performed to assess the volumetric density of various tissue components: the blood clot, vascularized structures, provisional matrix, osteoid, mineralized bone, bone debris, residual tissue, and old bone. Significantly more bone debris was found at 1 week in the conventionally-prepared defects compared to the piezo surgically-prepared defects. At 2 and 3 weeks, a newly-formed hard tissue bridge, mainly composed of woven bone, was seen; however, no statistically-significant differences were observed. At 5 weeks, the defects were completely filled with newly-formed bone. The defects prepared by piezo surgery showed a significantly decreased proportion of bone debris at 1 week, compared to conventional rotary bur defect. © 2014 Wiley Publishing Asia Pty Ltd.

  2. Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique

    PubMed Central

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-01-01

    Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050

  3. The Importance of Considering Differences in Study Design in Network Meta-analysis: An Application Using Anti-Tumor Necrosis Factor Drugs for Ulcerative Colitis.

    PubMed

    Cameron, Chris; Ewara, Emmanuel; Wilson, Florence R; Varu, Abhishek; Dyrda, Peter; Hutton, Brian; Ingham, Michael

    2017-11-01

    Adaptive trial designs present a methodological challenge when performing network meta-analysis (NMA), as data from such adaptive trial designs differ from conventional parallel design randomized controlled trials (RCTs). We aim to illustrate the importance of considering study design when conducting an NMA. Three NMAs comparing anti-tumor necrosis factor drugs for ulcerative colitis were compared and the analyses replicated using Bayesian NMA. The NMA comprised 3 RCTs comparing 4 treatments (adalimumab 40 mg, golimumab 50 mg, golimumab 100 mg, infliximab 5 mg/kg) and placebo. We investigated the impact of incorporating differences in the study design among the 3 RCTs and presented 3 alternative methods on how to convert outcome data derived from one form of adaptive design to more conventional parallel RCTs. Combining RCT results without considering variations in study design resulted in effect estimates that were biased against golimumab. In contrast, using the 3 alternative methods to convert outcome data from one form of adaptive design to a format more consistent with conventional parallel RCTs facilitated more transparent consideration of differences in study design. This approach is more likely to yield appropriate estimates of comparative efficacy when conducting an NMA, which includes treatments that use an alternative study design. RCTs based on adaptive study designs should not be combined with traditional parallel RCT designs in NMA. We have presented potential approaches to convert data from one form of adaptive design to more conventional parallel RCTs to facilitate transparent and less-biased comparisons.

  4. Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

    PubMed

    Ullattuthodi, Sujana; Cherian, Kandathil Phillip; Anandkumar, R; Nambiar, M Sreedevi

    2017-01-01

    This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t -test and analysis of variance (ANOVA). The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings ( P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings ( P < 0.05). Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference.

  5. Pars Plana-Modified versus Conventional Ahmed Glaucoma Valve in Patients Undergoing Penetrating Keratoplasty: A Prospective Comparative Randomized Study.

    PubMed

    Parihar, Jitendra Kumar Singh; Jain, Vaibhav Kumar; Kaushik, Jaya; Mishra, Avinash

    2017-03-01

    To compare the outcome of pars-plana-modified Ahmed glaucoma valve (AGV) versus limbal-based conventional AGV into the anterior chamber, in patients undergoing penetrating keratoplasty (PK) for glaucoma with coexisting corneal diseases. In this prospective randomized clinical trial, 58 eyes of 58 patients with glaucoma and coexisting corneal disease were divided into two groups. Group 1 (29 eyes of 29 patients) included patients undergoing limbal-based conventional AGV into the anterior chamber (AC) along-with PK and group 2 (29 eyes of 29 patients) included those undergoing pars-plana-modified AGV along-with PK. Outcome measures included corneal graft clarity, intraocular pressure (IOP), number of antiglaucoma medications, and postoperative complications. Patients were followed up for a minimum period of 2 years. Out of 58 eyes (58 patients), 50 eyes (50 patients: 25 eyes of 25 patients each in group 1 and group 2) completed the study and were analyzed. Complete success rate for AGV (group 1: 76%; group 2: 72%; p = 0.842) and corneal graft clarity (group 1: 68%; group 2: 76%; p = 0.081) were comparable between the two groups at 2 years. Graft failure was more in conventional AGV (32%) as compared to pars plana-modified AGV (24%) but not statistically significant (p = 0.078) at 2 years. Though both procedures were comparable in various outcome measures, pars-plana-modified AGV is a viable option for patients undergoing PK, as it provides a relatively better corneal graft survival rate and lesser complications that were associated with conventional AGV.

  6. Feasibility of ballistic strengthening exercises in neurologic rehabilitation.

    PubMed

    Williams, Gavin; Clark, Ross A; Hansson, Jessica; Paterson, Kade

    2014-09-01

    Conventional methods for strength training in neurologic rehabilitation are not task specific for walking. Ballistic strength training was developed to improve the functional transfer of strength training; however, no research has investigated this in neurologic populations. The aim of this pilot study was to evaluate the feasibility of applying ballistic principles to conventional leg strengthening exercises in individuals with mobility limitations as a result of neurologic injuries. Eleven individuals with neurologic injuries completed seated and reclined leg press using conventional and ballistic techniques. A 2 × 2 repeated-measures analysis of variance was used to compare power measures (peak movement height and peak velocity) between exercises and conditions. Peak jump velocity and peak jump height were greater when using the ballistic jump technique rather than the conventional concentric technique (P < 0.01). These findings suggest that when compared with conventional strengthening exercises, the incorporation of ballistic principles was associated with increased peak height and peak velocities.

  7. Comparison of performance due to guided hyperlearning, unguided hyperlearning, and conventional learning in mathematics: an empirical study

    NASA Astrophysics Data System (ADS)

    Fathurrohman, Maman; Porter, Anne; Worthy, Annette L.

    2014-07-01

    In this paper, the use of guided hyperlearning, unguided hyperlearning, and conventional learning methods in mathematics are compared. The design of the research involved a quasi-experiment with a modified single-factor multiple treatment design comparing the three learning methods, guided hyperlearning, unguided hyperlearning, and conventional learning. The participants were from three first-year university classes, numbering 115 students in total. Each group received guided, unguided, or conventional learning methods in one of the three different topics, namely number systems, functions, and graphing. The students' academic performance differed according to the type of learning. Evaluation of the three methods revealed that only guided hyperlearning and conventional learning were appropriate methods for the psychomotor aspects of drawing in the graphing topic. There was no significant difference between the methods when learning the cognitive aspects involved in the number systems topic and the functions topic.

  8. Research on Writing Conventions: U R What U Write

    ERIC Educational Resources Information Center

    Nelson, Leah; Feinstein, Sheryl G.

    2007-01-01

    The purpose of this quantitative study is to determine how secondary students use conventions in classroom composition assignments compared to the Internet writing outlets of e-mail, instant messaging, and blogs. Thirty-two ninth grade students were identified to participate in this study. Half of the participants were deeply involved in online…

  9. Prototype electronic stethoscope vs. conventional stethoscope for auscultation of heart sounds.

    PubMed

    Kelmenson, Daniel A; Heath, Janae K; Ball, Stephanie A; Kaafarani, Haytham M A; Baker, Elisabeth M; Yeh, Daniel D; Bittner, Edward A; Eikermann, Matthias; Lee, Jarone

    2014-08-01

    In an effort to decrease the spread of hospital-acquired infections, many hospitals currently use disposable plastic stethoscopes in patient rooms. As an alternative, this study examines a prototype electronic stethoscope that does not break the isolation barrier between clinician and patient and may also improve the diagnostic accuracy of the stethoscope exam. This study aimed to investigate whether the new prototype electronic stethoscope improved auscultation of heart sounds compared to the standard conventional isolation stethoscope. In a controlled, non-blinded, cross-over study, clinicians were randomized to identify heart sounds with both the prototype electronic stethoscope and a conventional stethoscope. The primary outcome was the score on a 10-question heart sound identification test. In total, 41 clinicians completed the study. Subjects performed significantly better in the identification of heart sounds when using the prototype electronic stethoscope (median = 9 [7-10] vs. 8 [6-9] points, p value <0.0001). Subjects also significantly preferred the prototype electronic stethoscope. Clinicians using a new prototype electronic stethoscope achieved greater accuracy in identification of heart sounds and also universally favoured the new device, compared to the conventional stethoscope.

  10. Comparison of piezosurgery and conventional rotative instruments in direct sinus lifting.

    PubMed

    Delilbasi, Cagri; Gurler, Gokhan

    2013-12-01

    The purpose of this study was to compare the intraoperative and postoperative effects of Piezosurgery and conventional rotative instruments in direct sinus lifting procedure. Twenty-three patients requiring direct sinus lifting were enrolled. The osteotomy and sinus membrane elevation were performed either with Piezosurgery tips or rotative diamond burs and manual membrane elevators. Time elapsed between bony window opening and completion of membrane elevation (duration), incidence of membrane perforation, visibility of the operation site, postoperative pain, swelling, sleeping, eating, phonetics, daily routine, and missed work as well as patient's expectation before and experience after the operation were evaluated. There was no significant difference between Piezosurgery and conventional groups regarding incidence of membrane perforation, duration, and operation site visibility as well as patient's expectation before and experience after the operation (P > 0.05). However, there were significantly more pain and swelling in the conventional group compared with the Piezosurgery group (P ≤ 0.05). Sinus lifting procedure performed with Piezosurgery causes less pain and swelling postoperatively compared with conventional technique. Patients' daily life activities and experience about the operation are not affected from the surgical technique.

  11. Modification of UASB reactor by using CFD simulations for enhanced treatment of municipal sewage.

    PubMed

    Das, Suprotim; Sarkar, Supriya; Chaudhari, Sanjeev

    2018-02-01

    Up-flow anaerobic sludge blanket (UASB) has been in use since last few decades for the treatment of organic wastewaters. However, the performance of UASB reactor is quite low for treatment of low strength wastewaters (LSWs) due to less biogas production leading to poor mixing. In the present research work, a modification was done in the design of UASB to improve mixing of reactor liquid which is important to enhance the reactor performance. The modified UASB (MUASB) reactor was designed by providing a slanted baffle along the height of the reactor having an angle of 5.7° with the vertical wall. A two-dimensional computational fluid dynamics (CFD) simulation of three phase gas-liquid-solid flow in MUASB reactor was performed and compared with conventional UASB reactor. The CFD study indicated better mixing in terms of vorticity magnitude in MUASB reactor as compared to conventional UASB, which was reflected in the reactor performance. The performance of MUASB was compared with conventional UASB reactor for the onsite treatment of domestic sewage as LSW. Around 16% higher total chemical oxygen demand removal efficiency was observed in MUASB reactor as compared to conventional UASB during this study. Therefore, this MUASB model demonstrates a qualitative relationship between mixing and performance during the treatment of LSW. From the study, it seems that MUASB holds promise for field applications.

  12. Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison.

    PubMed

    Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D

    2013-11-01

    There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.

  13. High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability.

    PubMed

    Barkagan, Michael; Contreras-Valdes, Fernando M; Leshem, Eran; Buxton, Alfred E; Nakagawa, Hiroshi; Anter, Elad

    2018-05-30

    PV reconnection is often the result of catheter instability and tissue edema. High-power short-duration (HP-SD) ablation strategies have been shown to improve atrial linear continuity in acute pre-clinical models. This study compares the safety, efficacy and long-term durability of HP-SD ablation with conventional ablation. In 6 swine, 2 ablation lines were performed anterior and posterior to the crista terminalis, in the smooth and trabeculated right atrium, respectively; and the right superior PV was isolated. In 3 swine, ablation was performed using conventional parameters (THERMOCOOL-SMARTTOUCH ® SF; 30W/30 sec) and in 3 other swine using HP-SD parameters (QDOT-MICRO™, 90W/4 sec). After 30 days, linear integrity was examined by voltage mapping and pacing, and the heart and surrounding tissues were examined by histopathology. Acute line integrity was achieved with both ablation strategies; however, HP-SD ablation required 80% less RF time compared with conventional ablation (P≤0.01 for all lines). Chronic line integrity was higher with HP-SD ablation: all 3 posterior lines were continuous and transmural compared to only 1 line created by conventional ablation. In the trabeculated tissue, HP-SD ablation lesions were wider and of similar depth with 1 of 3 lines being continuous compared to 0 of 3 using conventional ablation. Chronic PVI without stenosis was evident in both groups. There were no steam-pops. Pleural markings were present in both strategies, but parenchymal lung injury was only evident with conventional ablation. HP-SD ablation strategy results in improved linear continuity, shorter ablation time, and a safety profile comparable to conventional ablation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Utility of a Newly Designed Film Holder for Premolar Bitewing Radiography.

    PubMed

    Safi, Yaser; Esmaeelinejad, Mohammad; Vasegh, Zahra; Valizadeh, Solmaz; Aghdasi, Mohammad Mehdi; Sarani, Omid; Afsahi, Mahmoud

    2015-11-01

    Bitewing radiography is a valuable technique for assessment of proximal caries, alveolar crest and periodontal status. Technical errors during radiography result in erroneous radiographic interpretation, misdiagnosis, possible mistreatment or unnecessary exposure of patient for taking a repeat radiograph. In this study, we aimed to evaluate the efficacy of a film holder modified from the conventional one and compared it with that of conventional film holder. Our study population comprised of 70 patients who were referred to the Radiology Department for bilateral premolar bitewing radiographs as requested by their attending clinician. Bitewing radiographs in each patient were taken using the newly designed holder in one side and the conventional holder in the other side. The acceptability of the two holders from the perspectives of the technician and patients was determined using a 0-20 point scale. The frequency of overlap and film positioning errors was calculated for each method. The conventional holder had greater acceptability among patients compared to the newly designed holder (mean score of 16.59 versus 13.37). From the technicians' point of view, the newly designed holder was superior to the conventional holder (mean score of 17.33 versus 16.44). The frequency of overlap was lower using the newly designed holder (p<0.001) and it allowed more accurate film positioning (p=0.005). The newly designed holder may facilitate the process of radiography for technicians and may be associated with less frequency of radiographic errors compared to the conventional holder.

  15. A review of the application of propensity score methods yielded increasing use, advantages in specific settings, but not substantially different estimates compared with conventional multivariable methods

    PubMed Central

    Stürmer, Til; Joshi, Manisha; Glynn, Robert J.; Avorn, Jerry; Rothman, Kenneth J.; Schneeweiss, Sebastian

    2006-01-01

    Objective Propensity score analyses attempt to control for confounding in non-experimental studies by adjusting for the likelihood that a given patient is exposed. Such analyses have been proposed to address confounding by indication, but there is little empirical evidence that they achieve better control than conventional multivariate outcome modeling. Study design and methods Using PubMed and Science Citation Index, we assessed the use of propensity scores over time and critically evaluated studies published through 2003. Results Use of propensity scores increased from a total of 8 papers before 1998 to 71 in 2003. Most of the 177 published studies abstracted assessed medications (N=60) or surgical interventions (N=51), mainly in cardiology and cardiac surgery (N=90). Whether PS methods or conventional outcome models were used to control for confounding had little effect on results in those studies in which such comparison was possible. Only 9 out of 69 studies (13%) had an effect estimate that differed by more than 20% from that obtained with a conventional outcome model in all PS analyses presented. Conclusions Publication of results based on propensity score methods has increased dramatically, but there is little evidence that these methods yield substantially different estimates compared with conventional multivariable methods. PMID:16632131

  16. Computed Tomography Window Blending: Feasibility in Thoracic Trauma.

    PubMed

    Mandell, Jacob C; Wortman, Jeremy R; Rocha, Tatiana C; Folio, Les R; Andriole, Katherine P; Khurana, Bharti

    2018-02-07

    This study aims to demonstrate the feasibility of processing computed tomography (CT) images with a custom window blending algorithm that combines soft-tissue, bone, and lung window settings into a single image; to compare the time for interpretation of chest CT for thoracic trauma with window blending and conventional window settings; and to assess diagnostic performance of both techniques. Adobe Photoshop was scripted to process axial DICOM images from retrospective contrast-enhanced chest CTs performed for trauma with a window-blending algorithm. Two emergency radiologists independently interpreted the axial images from 103 chest CTs with both blended and conventional windows. Interpretation time and diagnostic performance were compared with Wilcoxon signed-rank test and McNemar test, respectively. Agreement with Nexus CT Chest injury severity was assessed with the weighted kappa statistic. A total of 13,295 images were processed without error. Interpretation was faster with window blending, resulting in a 20.3% time saving (P < .001), with no difference in diagnostic performance, within the power of the study to detect a difference in sensitivity of 5% as determined by post hoc power analysis. The sensitivity of the window-blended cases was 82.7%, compared to 81.6% for conventional windows. The specificity of the window-blended cases was 93.1%, compared to 90.5% for conventional windows. All injuries of major clinical significance (per Nexus CT Chest criteria) were correctly identified in all reading sessions, and all negative cases were correctly classified. All readers demonstrated near-perfect agreement with injury severity classification with both window settings. In this pilot study utilizing retrospective data, window blending allows faster preliminary interpretation of axial chest CT performed for trauma, with no significant difference in diagnostic performance compared to conventional window settings. Future studies would be required to assess the utility of window blending in clinical practice. Copyright © 2018 The Association of University Radiologists. All rights reserved.

  17. Radiosurgical fistulotomy; an alternative to conventional procedure in fistula in ano.

    PubMed

    Gupta, Pravin J

    2003-01-01

    Most surgeons continue to prefer the classic lay open technique [fistulotomy] as the gold standard of treatment in anal fistula. In this randomized study, a comparison is made between conventional fistulotomy and fistulotomy performed by a radio frequency device. One hundred patients of low anal fistula posted for fistulotomy were randomized prospectively to either a conventional or radio frequency technique. Parameters measured included time taken for the procedure, amount of blood loss, postoperative pain, return to work, and recurrence rate. The patient demographic was comparable in 2 groups. The radio frequency fistulotomy was quicker as compared to a conventional one [22 versus 37 minutes, p = 0.001], amount of bleeding was significantly less [47 ml versus 134 ml, p = 0.002], and hospital stay was less when patient was operated by radio frequency method [37 hours versus 56 hours in conventional method, p = 0.001]. The postoperative pain in the first 24 hours was more in conventional group [2 to 5 versus 0 to 3 on visual analogue scale]. The patients from radio frequency group resumed their duties early with a reduced healing period of the wounds [47 versus 64 days, p = 0.01]. The recurrence or failure rates were comparable in the radio frequency and conventional groups [2% versus 6%]. Fistulotomy procedure using a radio frequency technique has significant advantages over a conventional procedure with regard to operation time, blood loss, return to normal activity, and healing time of the wound.

  18. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    PubMed

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  19. Randomized clinical study comparing piezosurgery and conventional rotatory surgery in mandibular cyst enucleation.

    PubMed

    Pappalardo, Sabrina; Guarnieri, Renzo

    2014-07-01

    The aim of the present study is to compare piezoelectric surgery to the conventional rotatory surgery in mandibular cyst enucleation, and to determine the 2 method's suitability and the postoperative outcomes. Eighty patients were included in the study. 35 male and 45 female, which showed cystic mandibular lesions, compared with the inferior alveolar nerve or the mental nerve. The patients were randomly divided into two groups. In the test group, cystectomy was performed using conventional rotatory instrumentation (rotatory-group), and in the other one piezoelectric surgery (piezo-group). The swelling was documented 24/48/72 h and 1 week post-surgery and the patients recorded their subjective postoperative pain daily for 7 days using a Visual Analog Scale (VAS). Patients treated with piezoelectric technique have presented a lower VAS, minor swelling and less recovery time compared to the rotatory-group. No lesions of the mandible nerve were detected with piezosurgery whereas surgery with rotary instruments resulted in 8% hypesthesia at least up to one week. The results of this study suggest that piezosurgery may be considered effective in cyst enucleation compared to traditional procedures with burs, since it grants the patients significantly less post-surgical pain and swelling. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Characterisation of debris from laser and mechanical cutting of bone.

    PubMed

    Rachmanis, Nikolaos; McGuinness, Garrett B; McGeough, Joseph A

    2014-07-01

    Laser cutting of bones has been proposed as a technology in orthopaedic surgery. In this short study, the laser-bone interaction was examined using a pulsed erbium-doped yttrium aluminium garnet laser and compared to a conventional cutting technique. Microscopic analysis revealed the nature of waste debris and showed higher proportions of finer particles for conventional sagittal sawing compared to laser cutting. © IMechE 2014.

  1. The early psychological adjustment of cleft patients after maxillary distraction osteogenesis and conventional orthognathic surgery: a preliminary study.

    PubMed

    Cheung, Lim Kwong; Loh, John Ser Pheng; Ho, Samuel M Y

    2006-12-01

    To compare the early psychological changes of cleft lip and palate (CLP) and noncleft patients after maxillofacial corrective surgery, including maxillary distraction osteogenesis and conventional orthognathic surgery. Nine CLP patients were compared with a group of 9 non-CLP patients having similar dentofacial deformities in a prospective longitudinal cohort study. Five of the CLP patients underwent maxillary distraction osteogenesis and 4 underwent conventional orthognathic surgery. A control group of 9 noncleft patients received conventional orthognathic surgery. All patients completed a set of questionnaires to enable their psychological profile to be assessed. The data were collected immediately before surgery (T1), and at 3 weeks (T2) and 12 weeks (T3) after surgery. The CLP patients treated with distraction osteogenesis were happier, but had a higher level of social anxiety and distress than the CLP patients receiving conventional orthognathic surgery. On the other hand, the CLP patients overall were happier, with lower social anxiety and distress, than the noncleft control group. The CLP patients showed a higher level of parental self-esteem than the noncleft patients. This preliminary study shows that CLP patients were generally happier, and had a higher level of parental support, than normal patients suffering from dentofacial deformities. Maxillary distraction osteogenesis seemed to induce a higher level of anxiety and distress in CLP patients than conventional orthognathic surgery in both cleft and noncleft patients.

  2. Randomized controlled pilot study to compare Homeopathy and Conventional therapy in Acute Otitis Media.

    PubMed

    Sinha, M N; Siddiqui, V A; Nayak, C; Singh, Vikram; Dixit, Rupali; Dewan, Deepti; Mishra, Alok

    2012-01-01

    To compare the effectiveness of Homeopathy and Conventional therapy in Acute Otitis Media (AOM). A randomized placebo-controlled parallel group pilot study of homeopathic vs conventional treatment for AOM was conducted in Jaipur, India. Patients were randomized by a computer generated random number list to receive either individualized homeopathic medicines in fifty millesimal (LM) potencies, or conventional treatment including analgesics, antipyretics and anti-inflammatory drugs. Patients who did not improve were prescribed antibiotics at the 3rd day. Outcomes were assessed by the Acute Otitis Media-Severity of Symptoms (AOM-SOS) Scale and Tympanic Membrane Examination over 21 days. 81 patients were included, 80 completed follow-up: 41 for conventional and 40 for homeopathic treatment. In the Conventional group, all 40 (100%) patients were cured, in the Homeopathy group, 38 (95%) patients were cured while 02 (5%) patients were lost to the last two follow-up. By the 3rd day of treatment, 4 patients were cured in Homeopathy group but in Conventional group only one patient was cured. In the Conventional group antibiotics were prescribed in 39 (97.5%), no antibiotics were required in the Homeopathy group. 85% of patients were prescribed six homeopathic medicines. Individualized homeopathy is an effective conventional treatment in AOM, there were no significant differences between groups in the main outcome. Symptomatic improvement was quicker in the Homeopathy group, and there was a large difference in antibiotic requirements, favouring homeopathy. Further work on a larger scale should be conducted. Copyright © 2011 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  3. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness

    PubMed Central

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726

  4. Comparative evaluation of the amount of debris extruded apically using conventional syringe, passive ultrasonic irrigation and EndoIrrigator Plus system: An in vitro study

    PubMed Central

    Shetty, Vidhi Prabhakar; Naik, Balaram Damodar; Pachlag, Amit Kashinath; Yeli, Mahantesh Mrityunjay

    2017-01-01

    Aim: The aim of this study is to compare the effects of conventional syringe, passive ultrasonic irrigation (PUI), and EndoIrrigator Plus on the amount of apically extruded debris. Materials and Methods: Thirty extracted human mandibular premolars were selected and randomly assigned to three groups (n = 10). The root canals were irrigated with conventional syringe, PUI, and EndoIrrigator Plus. Sodium hypochlorite was used as an irrigant, and debris was collected in a previously described experimental model (Myers and Montgomery 1991). It was then stored in an incubator at 37°C for 10 days to evaporate the irrigant before weighing the dry debris. The mean weight of debris was assessed, one-way analysis of variance was used for comparison of values, and post hoc Tukey's test was used between groups (P = 0.05). Results: The EndoIrrigator Plus group extruded significantly less debris than PUI and conventional syringe groups (P < 0.05). Furthermore, PUI group extruded significantly less debris than conventional syringe irrigation group (P < 0.05). Conclusions: 1. All the three irrigation systems were associated with apical extrusion of debris, 2. EndoIrrigator Plus system extruded significantly less debris than the PUI system and the conventional syringe irrigation system, 3. PUI system extruded significantly less debris than the conventional syringe irrigation system. PMID:29430092

  5. Ultrasonic dissection versus conventional electrocautery during gastrectomy for gastric cancer: a meta-analysis of randomized controlled trials.

    PubMed

    Sun, Z C; Xu, W G; Xiao, X M; Yu, W H; Xu, D M; Xu, H M; Gao, H L; Wang, R X

    2015-04-01

    Use of ultrasonic surgical instrument is gaining popularity for dissection and coagulation in open surgery. However, there is still no consensus on the efficacy and safety of its use compared with conventional surgical technique in open gastrectomy for gastric cancer. The aim of this meta-analysis was to evaluate the role and surgical outcomes of ultrasonic dissection (UD) compared with conventional electrocautery (EC). A systematic literature search was performed to identify all studies comparing UD and EC in gastric cancer surgery. Intraoperative and postoperative outcomes were compared using weighted mean differences (WMDs) and odds ratios (ORs). Five studies were included in this meta-analysis, comprising 489 patients. Meta-analysis results showed that compared with EC, UD was associated with significantly shorter operation time (P = 0.03), less intraoperative blood loss (P = 0.002), lower morbidity (P = 0.02), and reduced postoperative hospital stay (P = 0.03). However, there was no significant difference between the two surgical techniques with regards to postoperative abdominal drainage (P = 0.17), and total cost in hospital (P = 0.59). Compared to EC, the use of UD during open gastrectomy can provide several improved outcomes for operation time, intraoperative blood loss, overall morbidity, and postoperative hospital stay. It appears that UD can be used instead of conventional EC in open gastric cancer surgery, although more larger trials with long follow-up should be performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

    PubMed

    Mirzakouchaki, Behnam; Shirazi, Sajjad; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-02-01

    Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.

  7. Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

    PubMed Central

    Mirzakouchaki, Behnam; Sharghi, Reza; Shirazi, Samaneh; Moghimi, Mahsan; Shahrbaf, Shirin

    2016-01-01

    Background Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. Material and Methods 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. Results The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. Conclusions The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. PMID:26855704

  8. Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction.

    PubMed

    Naghibi, Saeed; Seifirad, Sirous; Adami Dehkordi, Mahboobeh; Einolghozati, Sasan; Ghaffarian Eidgahi Moghadam, Nafiseh; Akhavan Rezayat, Amir; Seifirad, Soroush

    2016-01-01

    Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients.

  9. Tretinoin Nanogel 0.025% Versus Conventional Gel 0.025% in Patients with Acne Vulgaris: A Randomized, Active Controlled, Multicentre, Parallel Group, Phase IV Clinical Trial

    PubMed Central

    Chandrashekhar, B S; Anitha, M.; Ruparelia, Mukesh; Vaidya, Pradyumna; Aamir, Riyaz; Shah, Sunil; Thilak, S; Aurangabadkar, Sanjeev; Pal, Sandeep; Saraswat, Abir

    2015-01-01

    Background: Conventional topical tretinoin formulation is often associated with local adverse events. Nanogel formulation of tretinoin has good physical stability and enables good penetration of tretinoin into the pilo-sebaceous glands. Aim: The present study was conducted to assess the efficacy and safety of a nanogel formulation of tretinoin as compared to its conventional gel formulation in the treatment of acne vulgaris of the face. Materials and Methods: This randomized, active controlled, multicentric, phase IV clinical trial evaluated the treatment of patients with acne vulgaris of the face by the two gel formulations locally applied once daily at night for 12 wk. Acne lesion counts (inflammatory, non-inflammatory & total) and severity grading were carried out on the monthly scheduled visits along with the tolerability assessments. Results: A total of 207 patients were randomized in the study. Reductions in the total (72.9% vs. 65.0%; p = 0.03) and inflammatory (78.1% vs. 66.9%; p = 0.02) acne lesions were reported to be significantly greater with the nanogel formulation as compared to the conventional gel formulation. Local adverse events were significantly less (p = 0.04) in the nanogel group (13.3%) as compared to the conventional gel group (24.7%). Dryness was the most common adverse event reported in both the treatment groups while peeling of skin, burning sensation and photosensitivity were reported in patients using the conventional gel only. Conclusion: In the treatment of acne vulgaris of the face, tretinoin nanogel formulation appears to be more effective and better tolerated than the conventional gel formulation. PMID:25738069

  10. High-frequency, high-intensity transcutaneous electrical nerve stimulation as treatment of pain after surgical abortion.

    PubMed

    Platon, B; Andréll, P; Raner, C; Rudolph, M; Dvoretsky, A; Mannheimer, C

    2010-01-01

    The aim of the study was to compare the pain-relieving effect and the time spent in the recovery ward after treatment with high-frequency, high-intensity transcutaneous electrical nerve stimulation (TENS) or intravenous (IV) conventional pharmacological treatment after surgical abortion. Two-hundred women who underwent surgical abortion and postoperatively reported a visual analogue scale (VAS) pain score3 were included. The patients were randomised to TENS or conventional pharmacological treatment for their postoperative pain. The TENS treatment was given with a stimulus intensity between 20 and 60 mA during 1 min and repeated once if insufficient pain relief (VAS3). In the conventional pharmacological treatment group, a maximum dose of 100 microg fentanyl was given IV. There was no difference between the groups with regard to pain relief according to the VAS pain score (TENS=VAS 1.3 vs. IV opioids=VAS 1.6; p=0.09) upon discharge from the recovery ward. However, the patients in the TENS group spent shorter time (44 min) in the recovery ward than the conventional pharmacological treatment group (62 min; p<0.0001). The number of patients who needed additional analgesics in the recovery ward was comparable in both groups, as was the reported VAS pain score upon leaving the hospital (TENS=2.0 vs. conventional pharmacological treatment=1.8, NS). These results suggest that the pain-relieving effect of TENS seems to be comparable to conventional pharmacological treatment with IV opioids. Hence, TENS may be a suitable alternative to conventional pain management with IV opioids after surgical abortion. Copyright 2009 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  11. Proposal of ICI cancellation using opposite weightings on symmetric subcarrier pairs in CO-OFDM systems

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Chen, Xuemei; Deng, Mingliang; Zeng, Dengke; Yang, Heming; Qiu, Kun

    2015-08-01

    We propose a novel ICI cancellation using opposite weighting on symmetric subcarrier pairs to combat the linear phase noise of laser source and the nonlinear phase noise resulted from the fiber nonlinearity. We compare the proposed ICI cancellation scheme with conventional OFDM and the ICI self-cancellation at the same raw bit rate of 35.6 Gb/s. In simulations, the proposed ICI cancellation scheme shows better phase noise tolerance compared with conventional OFDM and has similar phase noise tolerance with the ICI self-cancellation. The laser linewidth is about 13 MHz at BER of 2 × 10-3 with ICI cancellation scheme while it is 5 MHz in conventional OFDM. We also study the nonlinearity tolerance and find that the proposed ICI cancellation scheme is better compared with the other two schemes which due to the first order nonlinearity mitigation. The launch power is 7 dBm for the proposed ICI cancellation scheme and its SNR improves by 4 dB or 3 dB compared with the ICI self-cancellation or conventional OFDM at BER of 1.1 × 10-3, respectively.

  12. Flow and Turbulence Modeling and Computation of Shock Buffet Onset for Conventional and Supercritical Airfoils

    NASA Technical Reports Server (NTRS)

    Bartels, Robert E.

    1998-01-01

    Flow and turbulence models applied to the problem of shock buffet onset are studied. The accuracy of the interactive boundary layer and the thin-layer Navier-Stokes equations solved with recent upwind techniques using similar transport field equation turbulence models is assessed for standard steady test cases, including conditions having significant shock separation. The two methods are found to compare well in the shock buffet onset region of a supercritical airfoil that involves strong trailing-edge separation. A computational analysis using the interactive-boundary layer has revealed a Reynolds scaling effect in the shock buffet onset of the supercritical airfoil, which compares well with experiment. The methods are next applied to a conventional airfoil. Steady shock-separated computations of the conventional airfoil with the two methods compare well with experiment. Although the interactive boundary layer computations in the shock buffet region compare well with experiment for the conventional airfoil, the thin-layer Navier-Stokes computations do not. These findings are discussed in connection with possible mechanisms important in the onset of shock buffet and the constraints imposed by current numerical modeling techniques.

  13. Tablet-based cardiac arrest documentation: a pilot study.

    PubMed

    Peace, Jack M; Yuen, Trevor C; Borak, Meredith H; Edelson, Dana P

    2014-02-01

    Conventional paper-based resuscitation transcripts are notoriously inaccurate, often lacking the precision that is necessary for recording a fast-paced resuscitation. The aim of this study was to evaluate whether a tablet computer-based application could improve upon conventional practices for resuscitation documentation. Nurses used either the conventional paper code sheet or a tablet application during simulated resuscitation events. Recorded events were compared to a gold standard record generated from video recordings of the simulations and a CPR-sensing defibrillator/monitor. Events compared included defibrillations, medication deliveries, and other interventions. During the study period, 199 unique interventions were observed in the gold standard record. Of these, 102 occurred during simulations recorded by the tablet application, 78 by the paper code sheet, and 19 during scenarios captured simultaneously by both documentation methods These occurred over 18 simulated resuscitation scenarios, in which 9 nurses participated. The tablet application had a mean sensitivity of 88.0% for all interventions, compared to 67.9% for the paper code sheet (P=0.001). The median time discrepancy was 3s for the tablet, and 77s for the paper code sheet when compared to the gold standard (P<0.001). Similar to prior studies, we found that conventional paper-based documentation practices are inaccurate, often misreporting intervention delivery times or missing their delivery entirely. However, our study also demonstrated that a tablet-based documentation method may represent a means to substantially improve resuscitation documentation quality, which could have implications for resuscitation quality improvement and research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. The MAGEC system for spinal lengthening in children with scoliosis: A NICE Medical Technology Guidance.

    PubMed

    Jenks, Michelle; Craig, Joyce; Higgins, Joanne; Willits, Iain; Barata, Teresa; Wood, Hannah; Kimpton, Christine; Sims, Andrew

    2014-12-01

    Scoliosis-structural lateral curvature of the spine-affects around four children per 1,000. The MAGEC system comprises a magnetically distractible spinal rod implant and an external remote controller, which lengthens the rod; this system avoids repeated surgical lengthening. Rod implants brace the spine internally and are lengthened as the child grows, preventing worsening of scoliosis and delaying the need for spinal fusion. The Medical Technologies Advisory Committee at the National Institute for Health and Care Excellence (NICE) selected the MAGEC system for evaluation in a NICE medical technologies guidance. Six studies were identified by the sponsor (Ellipse Technologies Inc.) as being relevant to the decision problem. Meta-analysis was used to compare the clinical evidence results with those of one conventional growth rod study, and equal efficacy of the two devices was concluded. The key weakness was selection of a single comparator study. The External Assessment Centre (EAC) identified 16 conventional growth rod studies and undertook meta-analyses of relevant outcomes. Its critique highlighted limitations around study heterogeneity and variations in baseline characteristics and follow-up duration, precluding the ability to draw firm conclusions. The sponsor constructed a de novo costing model showing that MAGEC rods generated cost savings of £9,946 per patient after 6 years, compared with conventional rods. The EAC critiqued and updated the model structure and inputs, calculating robust cost savings of £12,077 per patient with MAGEC rods compared with conventional rods over 6 years. The year of valuation was 2012. NICE issued a positive recommendation as supported by the evidence (Medical Technologies Guidance 18).

  15. Comparative study of the novel and conventional injection approach for inferior alveolar nerve block.

    PubMed

    Boonsiriseth, K; Sirintawat, N; Arunakul, K; Wongsirichat, N

    2013-07-01

    This study aimed to evaluate the efficacy of anesthesia obtained with a novel injection approach for inferior alveolar nerve block compared with the conventional injection approach. 40 patients in good health, randomly received each of two injection approaches of local anesthetic on each side of the mandible at two separate appointments. A sharp probe and an electric pulp tester were used to test anesthesia before injection, after injection when the patients' sensation changed, and 5 min after injection. This study comprised positive aspiration and intravascular injection 5% and neurovascular bundle injection 7.5% in the conventional inferior alveolar nerve block, but without occurrence in the novel injection approach. A visual analog scale (VAS) pain assessment was used during injection and surgery. The significance level used in the statistical analysis was p<0.05. For the novel injection approach compared with the conventional injection approach, no significant difference was found on the subjective onset, objective onset, operation time, duration of anesthesia and VAS pain score during operation, but the VAS pain score during injection was significantly different. The efficacy of inferior alveolar nerve block by the novel injection approach provided adequate anesthesia and caused less pain and greater safety during injection. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Defining the Pros and Cons of Open, Conventional Laparoscopy, and Robot-Assisted Pyeloplasty in a Developing Nation

    PubMed Central

    Pahwa, Archna R.; Girotra, Mohit; Abrahm, Rtika Ryfka; Kathuria, Sachin; Sharma, Ajay

    2014-01-01

    Introduction. Congenital pelviureteric junction obstruction (PUJO) is one of the most common causes of hydronephrosis. Historically, open dismembered pyeloplasty has been considered the gold standard intervention for correcting PUJO. The aim of this study was to compare the surgical and functional outcomes of three different approaches, namely, open, conventional laparoscopy, and robotic pyeloplasty. Material and Methods. 60 patients underwent minimally invasive pyeloplasty (30 conventional laparoscopies and 30 robotics) for congenital PUJO at a tertiary health center in India. Demographic, perioperative, and postoperative data were prospectively collected and analyzed. The data of these patients were retrospectively compared with another cohort of 30 patients who had undergone open pyeloplasty. Results. There was significant difference in operative time, time to drain removal, hospital stay, pain score, and complications rate between open and minimally invasive pyeloplasty (P < 0.05). SFI was considerably lesser in robotic as compared to conventional laparoscopy. The success rate in OP, CLP, and RP was 93.33, 96.67, and 96.67%. Conclusion. Robotic pyeloplasty is safe, effective, and feasible. It is associated with significantly lesser operative time, lesser blood loss, less pain, shorter hospital stay, and fewer complications. It is also associated with considerably lesser surgeon fatigue as compared to conventional laparoscopy pyeloplasty. PMID:24624138

  17. Selective extra levator versus conventional abdomino perineal resection: experience from a tertiary-care center

    PubMed Central

    Pai, Vishwas D.; Engineer, Reena; Patil, Prachi S.; Arya, Supreeta; Desouza, Ashwin L.

    2016-01-01

    Background To compare extra levator abdomino perineal resection (ELAPER) with conventional abdominoperineal resection (APER) in terms of short-term oncological and clinical outcomes. Methods This is a retrospective review of a prospectively maintained database including all the patients of rectal cancer who underwent APER at Tata Memorial Center between July 1, 2013, and January 31, 2015. Short-term oncological parameters evaluated included circumferential resection margin involvement (CRM), tumor site perforation, and number of nodes harvested. Peri operative outcomes included blood loss, length of hospital stay, postoperative perineal wound complications, and 30-day mortality. The χ2-test was used to compare the results between the two groups. Results Forty-two cases of ELAPER and 78 cases of conventional APER were included in the study. Levator involvement was significantly higher in the ELAPER compared with the conventional group; otherwise, the two groups were comparable in all the aspects. CRM involvement was seen in seven patients (8.9%) in the conventional group compared with three patients (7.14%) in the ELAPER group. Median hospital stay was significantly longer with ELAPER. The univariate analysis of the factors influencing CRM positivity did not show any significance. Conclusions ELAPER should be the preferred approach for low rectal tumors with involvement of levators. For those cases in which levators are not involved, as shown in preoperative magnetic resonance imaging (MRI), the current evidence is insufficient to recommend ELAPER over conventional APER. This stresses the importance of preoperative MRI in determining the best approach for an individual patient. PMID:27284466

  18. Arthroscopic undersurface rotator cuff repair versus conventional arthroscopic double-row rotator cuff repair - Comparable results at 2-year follow-up.

    PubMed

    Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng

    2018-01-01

    The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p < 0.001). Both arthroscopic undersurface rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.

  19. Comparison between laser terahertz emission microscope and conventional methods for analysis of polycrystalline silicon solar cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakanishi, Hidetoshi, E-mail: nakanisi@screen.co.jp; Ito, Akira, E-mail: a.ito@screen.co.jp; Takayama, Kazuhisa, E-mail: takayama.k0123@gmail.com

    2015-11-15

    A laser terahertz emission microscope (LTEM) can be used for noncontact inspection to detect the waveforms of photoinduced terahertz emissions from material devices. In this study, we experimentally compared the performance of LTEM with conventional analysis methods, e.g., electroluminescence (EL), photoluminescence (PL), and laser beam induced current (LBIC), as an inspection method for solar cells. The results showed that LTEM was more sensitive to the characteristics of the depletion layer of the polycrystalline solar cell compared with EL, PL, and LBIC and that it could be used as a complementary tool to the conventional analysis methods for a solar cell.

  20. Late outcomes of a randomized trial of high-frequency oscillation in neonates.

    PubMed

    Zivanovic, Sanja; Peacock, Janet; Alcazar-Paris, Mireia; Lo, Jessica W; Lunt, Alan; Marlow, Neil; Calvert, Sandy; Greenough, Anne

    2014-03-20

    Results from an observational study involving neonates suggested that high-frequency oscillatory ventilation (HFOV), as compared with conventional ventilation, was associated with superior small-airway function at follow-up. Data from randomized trials are needed to confirm this finding. We studied 319 adolescents who had been born before 29 weeks of gestation and had been enrolled in a multicenter, randomized trial that compared HFOV with conventional ventilation immediately after birth. The trial involved 797 neonates, of whom 592 survived to hospital discharge. We compared follow-up data from adolescents who had been randomly assigned to HFOV with follow-up data from those who had been randomly assigned to conventional ventilation, with respect to lung function and respiratory health, health-related quality of life, and functional status, as assessed with the use of questionnaires completed when the participants were 11 to 14 years of age. The primary outcome was forced expiratory flow at 75% of the expired vital capacity (FEF75). The HFOV group had superior results on a test of small-airway function (z score for FEF75, -0.97 with HFOV vs. -1.19 with conventional therapy; adjusted difference, 0.23 [95% confidence interval, 0.02 to 0.45]). There were significant differences in favor of HFOV in several other measures of respiratory function, including forced expiratory volume in 1 second, forced vital capacity, peak expiratory flow, diffusing capacity, and impulse-oscillometric findings. As compared with the conventional-therapy group, the HFOV group had significantly higher ratings from teachers in three of eight school subjects assessed, but there were no other significant differences in functional outcomes. In a randomized trial involving children who had been born extremely prematurely, those who had undergone HFOV, as compared with those who had received conventional ventilation, had superior lung function at 11 to 14 years of age, with no evidence of poorer functional outcomes. (Funded by the National Institute for Health Research Health Technology Assessment Programme and others.).

  1. How do the outcomes of the DEKA Arm compare to conventional prostheses?

    PubMed

    Resnik, Linda J; Borgia, Matthew L; Acluche, Frantzy; Cancio, Jill M; Latlief, Gail; Sasson, Nicole

    2018-01-01

    Objectives were to 1) compare self-reported function, dexterity, activity performance, quality of life and community integration of the DEKA Arm to conventional prostheses; and 2) examine differences in outcomes by conventional prosthesis type, terminal device type and by DEKA Arm configuration level. This was a two-part study; Part A consisted of in-laboratory training. Part B consisted of home use. Study participants were 23 prosthesis users (mean age = 45 ± 16; 87% male) who completed Part A, and 15 (mean age = 45 ± 18; 87% male) who completed Parts A and B. Outcomes including self-report and performance measures, were collected at Baseline using participants' personal prostheses and at the End of Parts A and B. Scores were compared using paired t-tests. Wilcoxon signed-rank tests were used to compare outcomes for the full sample, and for the sample stratified by device and terminal device type. Analysis of outcomes by configuration level was performed graphically. At the End of Part A activity performance using the DEKA Arm and conventional prosthesis was equivalent, but slower with the DEKA Arm. After Part B, performance using the DEKA Arm surpassed conventional prosthesis scores, and speed of activity completion was equivalent. Participants reported using the DEKA Arm to perform more activities, had less perceived disability, and less difficulty in activities at the End of A and B as compared to Baseline. No differences were observed in dexterity, prosthetic skill, spontaneity, pain, community integration or quality of life. Comparisons stratified by device type revealed similar patterns. Graphic comparisons revealed variations by configuration level. Participants using the DEKA Arm had less perceived disability and more engagement of the prosthesis in everyday tasks, although activity performance was slower. After home use experience, activity performance was improved and activity speed equivalent to using conventional prostheses.

  2. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

    PubMed

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F; Erlandsson, Kjell; Sharir, Tali; Roth, Nathaniel; Waddington, Wendy A; Berman, Daniel S; Ell, Peter J

    2010-08-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p<0.0001 for all). In six patients stress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. Fast and high-quality simultaneous DR MPI is feasible with D-SPECT in a single imaging session with comparable diagnostic performance and image quality to conventional SPECT and to a separate rest (201)Tl D-SPECT acquisition.

  3. Nutritional evaluation of canola meals produced from new varieties of canola seeds for poultry.

    PubMed

    Chen, X; Parr, C; Utterback, P; Parsons, C M

    2015-05-01

    This study evaluated the nutritional value of 14 canola meals from new varieties of canola and compared them to conventional canola meal samples and soybean meals in chickens. Five experiments that included different sources of canola meals or soybean meals were conducted. For each experiment, a precision-fed rooster assay with conventional or cecectomized roosters was conducted to determine TMEn or amino acid digestibility. Analyzed nutritional composition of the canola meal samples indicated increases in crude protein and amino acids for all test canola meals (49.41 to 50.58% crude protein on a dry matter basis) compared to conventional canola meals (40.73 to 43.01%). All test canola meals also contained lower amounts of neutral detergent fiber and acid detergent fiber. Most test canola meals had significantly higher TMEn values than the conventional canola meals (P < 0.05), but all were lower than the soybean meal (P < 0.05). The test canola meals had higher amino acid digestibility coefficients than conventional canola meals in Experiments 1, 2, and 4 (P < 0.05), and higher concentrations of digestible amino acids in all 5 experiments. The results of this study indicated that nutritional value of the canola meal from new varieties of canola was greater than conventional canola meal for poultry. © 2015 Poultry Science Association Inc.

  4. Perioperative surgical outcome of conventional and robot-assisted total laparoscopic hysterectomy.

    PubMed

    van Weelden, W J; Gordon, B B M; Roovers, E A; Kraayenbrink, A A; Aalders, C I M; Hartog, F; Dijkhuizen, F P H L J

    2017-01-01

    To evaluate surgical outcome in a consecutive series of patients with conventional and robot assisted total laparoscopic hysterectomy. A retrospective cohort study was performed among patients with benign and malignant indications for a laparoscopic hysterectomy. Main surgical outcomes were operation room time and skin to skin operating time, complications, conversions, rehospitalisation and reoperation, estimated blood loss and length of hospital stay. A total of 294 patients were evaluated: 123 in the conventional total laparoscopic hysterectomy (TLH) group and 171 in the robot TLH group. After correction for differences in basic demographics with a multivariate linear regression analysis, the skin to skin operating time was a significant 18 minutes shorter in robot assisted TLH compared to conventional TLH (robot assisted TLH 92m, conventional TLH 110m, p0.001). The presence or absence of previous abdominal surgery had a significant influence on the skin to skin operating time as did the body mass index and the weight of the uterus. Complications were not significantly different. The robot TLH group had significantly less blood loss and lower rehospitalisation and reoperation rates. This study compares conventional TLH with robot assisted TLH and shows shorter operating times, less blood loss and lower rehospitalisation and reoperation rates in the robot TLH group.

  5. Corticotomy-facilitated orthodontics using piezosurgery versus rotary instruments: an experimental study.

    PubMed

    Farid, Karim A; Mostafa, Yehya A; Kaddah, Mohammed A; El-Sharaby, Fouad Aly

    2014-10-01

    The aim of this study was to evaluate corticotomy-facilitated orthodontics (CFO) using piezosurgery versus conventional rotary instruments. Ten healthy adult male mongrel dogs of comparable age with a complete set of permanent dentition with average weights between 13-17 kilograms were used. CFO using conventional rotary instruments versus piezosurgery was performed on each dog in a split mouth design. For every dog, mandibular 2nd premolar retraction on each side was attempted after extracting 3rd premolars followed by corticotomy-facilitated orthodontics using conventional rotary surgical burs on the left side and an ultrasonic piezosurgery system on the right side of the same animal. Intraoral measurements of the rate of tooth movement were taken with a sliding caliper. Measurements were performed by the same operator at the time of surgery (appliance delivery) and every month for six months. The dogs were sacrificed after six months from initiation of tooth movement to evaluate the amount of tooth movement for both conventional rotary and piezosurgery corticotomy techniques. A statistically significantly higher mean amount of tooth movement for conventional rotary instrument versus the piezosurgery corticotomy technique was observed at all time intervals. Tooth movement was 1.6 times faster when CFO was done using conventional rotary instruments as compared to a piezosurgery device.

  6. Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions

    NASA Astrophysics Data System (ADS)

    Nugrahani, F.; Jazaldi, F.; Noerhadi, N. A. I.

    2017-08-01

    The field of orthodontics is always evolving,and this includes the use of innovative technology. One type of orthodontic technology is the development of three-dimensional (3D) digital study models that replace conventional study models made by stone. This study aims to compare the mesio-distal teeth width, intercanine width, and intermolar width measurements between a 3D digital study model and a conventional study model. Twelve sets of upper arch dental impressions were taken from subjects with non-crowding teeth. The impressions were taken twice, once with alginate and once with polivinylsiloxane. The alginate impressions used in the conventional study model and the polivinylsiloxane impressions were scanned to obtain the 3D digital study model. Scanning was performed using a laser triangulation scanner device assembled by the School of Electrical Engineering and Informatics at the Institut Teknologi Bandung and David Laser Scan software. For the conventional model, themesio-distal width, intercanine width, and intermolar width were measured using digital calipers; in the 3D digital study model they were measured using software. There were no significant differences between the mesio-distal width, intercanine width, and intermolar width measurments between the conventional and 3D digital study models (p>0.05). Thus, measurements using 3D digital study models are as accurate as those obtained from conventional study models

  7. Clinical evaluation of extraperitoneal colostomy without damaging the muscle layer of the abdominal wall.

    PubMed

    Dong, L-R; Zhu, Y-M; Xu, Q; Cao, C-X; Zhang, B-Z

    2012-01-01

    This study investigated whether extraperitoneal colostomy without damaging the muscle layer of the abdominal wall is an improved surgical procedure compared with conventional sigmoid colostomy in patients undergoing abdominoperineal resection. Patients with rectal cancer undergoing abdominoperineal resection were selected and randomly divided into two groups: the study group received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and the control group received conventional colostomy. Clinical data from both groups were analysed. A total of 128 patients were included: 66 received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and 62 received conventional colostomy. Significant differences between the two groups were found in relation to colostomy operating time, defaecation sensation, bowel control and overall stoma-related complications. Duration of postoperative hospital stay was also significantly different between the study groups. Extraperitoneal colostomy without damaging the muscle layer of the abdominal wall was found to be an improved procedure compared with conventional sigmoid colostomy in abdominoperineal resection, and may reduce colostomy-related complications, shorten operating time and postoperative hospital stay, and potentially improve patients' quality of life.

  8. Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

    PubMed

    Kumar, Sujeet; Singh, Shamsher; Hamsa P R, Rani; Ahmed, Sameer; Prasanthma; Bhatnagar, Apoorva; Sidhu, Manreet; Shetty, Pramod

    2014-05-01

    The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). An experimental model which consisted of 5 aligned stainless steel 0.022-in brackets was used to assess frictional forces which were produced by SLBs (self ligating brackets) and CELs (conventional elastomeric ligatures) with use of 0.016 nickel titanium, 0.018 nickel titanium, 0.017 X 0.025"stainless steel and 0.019 X 0.025"stainless steel wires. One way ANOVA test was used to study the effect of the bracket type, wire alloy and section on frictional resistance test . Conventional brackets produced highest levels of friction for all bracket/archwire combinations. Both Damon III and Forestadent brackets were found to produce significantly lower levels of friction when they were compared with elastomerically tied conventional brackets. SLBs are valid alternatives for low friction during sliding mechanics.

  9. Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    PubMed

    Lu, Huangling; Kalkman, Deborah N; Grundeken, Maik J; Tijssen, Jan G P; Wykrzykowska, Joanna J; de Winter, Robbert J; Koch, Karel T

    2018-02-01

    With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.

  10. What Really Matters in Synagogue Education: A Comparative Case Study of a Conventional School and an Alternative Program

    ERIC Educational Resources Information Center

    Litman, Lesley

    2017-01-01

    This article examines case studies of two part-time synagogue education programs, a conventional "Hebrew School" and an alternative program modeled after Jewish summer camp. Using the lens of teaching of Bible to children in Grades 3-5, the study provides insight into similarities and differences between the two types of programs and the…

  11. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    PubMed Central

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    Background There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. Objectives To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. Patients and Methods A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Results Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. Conclusion For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee. PMID:24348599

  12. Patient-centered outcomes comparing digital and conventional implant impression procedures: a randomized crossover trial.

    PubMed

    Joda, Tim; Brägger, Urs

    2016-12-01

    The aim of this randomized controlled trial was to compare patient-centered outcomes during digital and conventional implant impressions. In a crossover study design, intraoral scanning (IOS) [test] as well as classical polyether impressions [control] were both performed on 20 patients for single-tooth replacement with implant-supported crowns. The sequential distribution of either starting with the test or the control procedure was randomly selected. Patients' perception and satisfaction on the level of convenience-related factors were assessed with visual analogue scale (VAS) questionnaires. In addition, clinical work time was separately recorded for test and control procedures. Statistical analyses were performed with Wilcoxon signed-rank tests and corrected for multiple testing by the method of Holm. On VAS ranging from 0 to 100, patients scored a mean convenience level of 78.6 (SD ± 14.0) in favor of IOS compared to conventional impressions with 53.6 (SD ± 15.4) [P = 0.0001]. All included patients would prefer the digital workflow if in the future they could choose between the two techniques. Secondary, IOS was significantly faster with 14.8 min (SD ± 2.2) compared to the conventional approach with 17.9 min (SD ± 1.1) [P = 0.0001]. Based on the findings of this investigation, both impression protocols worked successfully for all study participants capturing the 3D implant positions. However, the digital technique emerges as the most preferred one according to patient-centered outcomes and was more time-effective compared to conventional impressions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Conventional and Accelerated-Solvent Extractions of Green Tea (Camellia sinensis) for Metabolomics-based Chemometrics

    PubMed Central

    Kellogg, Joshua J.; Wallace, Emily D.; Graf, Tyler N.; Oberlies, Nicholas H.; Cech, Nadja B.

    2018-01-01

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. PMID:28787673

  14. Mechanical and conventional manual sutures of the bronchial stump. A comparative study of 298 surgical patients.

    PubMed

    Péterffy, A; Calabrese, E

    1979-01-01

    A U.S.-made TA-30 model stapling device was utilized to close the bronchial stump in 146 patients, while conventional manual suturing with chromic catgut was performed for the same purpose in 152 patients. The two groups were comparable in respect of pre-operative status and operative diagnosis. Patients, in whom the stapler was utilized, showed a decreased incidence of bronchial fistula (1% vs. 3%) and empyema without fistula (1% vs. 3%). The stapler, compared with conventional manual sutures, allows a simpler and swifter suture of the bronchial stump, reduces the contamination of the operative field, achieves uniform and tighter closure of the bronchus, leaves a better preserved terminal blood perfusion of the stump and utilizes a more tolerated sewing material with less resultant tissue inflammation.

  15. Mastitis and related management factors in certified organic dairy herds in Sweden

    PubMed Central

    Hamilton, Cecilia; Emanuelson, Ulf; Forslund, Kristina; Hansson, Ingrid; Ekman, Torkel

    2006-01-01

    Background Mastitis is one of the major threats to animal health, in organic farming as well as conventional. Preliminary studies of organic dairy herds have indicated better udder health in such herds, as compared to conventional herds. The aim of this paper was to further study mastitis and management related factors in certified organic dairy herds. Methods An observational study of 26 certified organic dairy herds in mid-eastern Sweden was conducted during one year. A large-animal practitioner visited the herds three times and clinically examined and sampled cows, and collected information about general health and management routines. Data on milk production and disorders treated by a veterinarian in the 26 herds, as well as in 1102 conventional herds, were retrieved from official records. Multivariable logistic regression was used to assess associations between herd type (organic vs. conventional) and incidence of disorders. Results The organic herds that took part in the study ranged in size from 12 to 64 cows, in milk production from 3772 to 10334 kg per cow and year, and in bulk milk somatic cell counts from 83000 to 280000 cells/ml. The organic herds were found to have a lower incidence of clinical mastitis, teat injuries, and a lower proportion of cows with a high somatic cell count (as indicated by the UDS, Udder Disease Score) compared to conventional herds. The spectrum of udder pathogenic bacteria was similar to that found in other Swedish studies. Treatment of mastitis was found to be similar to what is practised in conventional herds. Homeopathic remedies were not widely used in the treatment of clinical mastitis. The calves in most of these organic herds suckled their dams for only a few days, which were not considered to substantially affect the udder health. The main management factor that was different from conventional herds was the feeding strategy, where organic herds used a larger share of forage. Conclusion Udder health in Swedish organic herds appears to be better than in conventional herds of comparable size and production. The major difference in management between the two types of farms is the proportion of concentrates fed. The mechanisms explaining the association between intensity of feeding and udder health in dairy cows require further research. PMID:16987390

  16. Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia.

    PubMed

    Peñarrocha-Oltra, D; Ata-Ali, J; Oltra-Moscardó, M-J; Peñarrocha-Diago, M-A; Peñarrocha, M

    2012-03-01

    To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. A total of 200 oral anesthetic procedures were carried out in 100 patients. The mean patient age was 28.6±9.92 years. Fifty-five vestibular infiltrations and 45 mandibular blocks were performed. All patients were also subjected to IA. The type of intervention (conservative or endodontic) exerted no significant influence (p=0.58 and p=0.62, respectively). The latency period was 8.52±2.44 minutes for the conventional techniques and 0.89±0.73 minutes for IA - the difference being statistically significant (p<0.05). Regarding patient anesthesia sensation, the infiltrative techniques lasted a maximum of one hour, the inferior alveolar nerve blocks lasted between 1-3 hours, and IA lasted only 2.5 minutes - the differences being statistically significant (p≤0.0000, Φ=0.29). Anesthetic success was recorded in 89% of the conventional procedures and in 78% of the IA. Most patients preferred IA (61%)(p=0.0032). The two anesthetic procedures have been compared for latency, duration of anesthetic effect, anesthetic success rate and patient preference. Intraosseous anesthesia has been shown to be a technique to be taken into account when planning conservative and endodontic treatments.

  17. Comparative effects of Facebook and conventional media on body image dissatisfaction.

    PubMed

    Cohen, Rachel; Blaszczynski, Alex

    2015-01-01

    Appearance comparison has consistently been shown to engender body image dissatisfaction. To date, most studies have demonstrated this relationship between appearance comparison and body image dissatisfaction in the context of conventional media images depicting the thin-ideal. Social comparison theory posits that people are more likely to compare themselves to similar others. Since social media forums such as Facebook involve one's peers, the current study aimed to determine whether the relationship between appearance comparison and body image dissatisfaction would be stronger for those exposed to social media images, compared to conventional media images. A sample of 193 female first year university students were randomly allocated to view a series of either Facebook or conventional media thin-ideal images. Participants completed questionnaires assessing pre- and post- image exposure measures of thin-ideal internalisation, appearance comparison, self-esteem, Facebook use and eating disorder risk. Type of exposure was not found to moderate the relationship between appearance comparison and changes in body image dissatisfaction. When analysed according to exposure type, appearance comparison only significantly predicted body image dissatisfaction change for those exposed to Facebook, but not conventional media. Facebook use was found to predict higher baseline body image dissatisfaction and was associated with higher eating disorder risk. The findings suggest the importance of extending the body image dissatisfaction literature by taking into account emerging social media formats. It is recommended that interventions for body image dissatisfaction and eating disorders consider appearance comparison processes elicited by thin-ideal content on social media forums, such as Facebook, in addition to conventional media.

  18. Implementing reduced-risk integrated pest management in fresh-market cabbage: improved net returns via scouting and timing of effective control.

    PubMed

    Burkness, Eric C; Hutchison, W D

    2008-04-01

    During 1998-2001, field studies were done to assess the efficacy of an integrated pest management (IPM) program using an action threshold and "reduced-risk" insecticides. The IPM program was compared with a conventional grower-based program. Program performance was evaluated based on management of Trichoplusia ni (Hiibner), Pieris (=Artogeia) rapae (L.), and Plutella xylostella (L.), as well as the economic impact of each program on net returns. The action threshold used in the IPM program consisted of 10% plants infested with T. ni larvae, based on previous small-plot experiment station trials. In all years of the study, the IPM program resulted in significantly lower percentages of plants infested than the conventional program or untreated check. The mean reduction in insecticide applications for the IPM program compared with the conventional program was 23.5%, whereas, on average, the costs of the IPM program were 46.0% higher than the conventional program. Pest reduction in the IPM program resulted in an average of 10.5% higher marketable yields than the conventional program. Percentages of marketable heads in the IPM program ranged from 82 to 99% and from 63 to 96% in the conventional program. Mean net returns for the IPM program exceeded the conventional program by $984.20/ha. These results indicated that the IPM program reduced insecticide use overall, even though costs of the IPM program, with either spinosad or indoxacarb, were sometimes higher. Overall, net returns of the IPM program were higher due to active pest scouting, improved application timing, and increases in marketable yield. Given the potential decrease in insecticide applications and increases in net profit resulting from this IPM program, additional analyses should be conducted to quantify the economic risk, or consistency of the results, to fully evaluate the benefits of the IPM program compared with a conventional program.

  19. A review of the impacts of tobacco heating system on indoor air quality versus conventional pollution sources.

    PubMed

    Kaunelienė, Violeta; Meišutovič-Akhtarieva, Marija; Martuzevičius, Dainius

    2018-05-08

    With the introduction of novel and potentially less polluting nicotine containing products to the market, the impacts of their usage to indoor air quality as opposed to conventional pollution sources must be reviewed and considered. This review study aimed to comparatively analyse changes in indoor air quality as the consequence of tobacco heating system (THS) generated pollution against general indoor air quality in various micro-environments, especially with combustion-based pollution sources present. Indoor concentrations of formaldehyde, acetaldehyde, benzene, toluene, nicotine and PM 2.5 were reviewed and compared; concentrations of other harmful and potentially harmful substances (HPHCs) were discussed. Generally, the usage of THS has been associated with lower or comparable indoor air pollutant concentrations compared against other conventional indoor sources or environments, in most cases distinguishable above background, thus potentially being associated with health effects at prolonged exposures as any other artificial air pollution source. In the controlled environment the use of THS (as well as an electronic cigarette) resulted in the lowest concentrations of formaldehyde, benzene, toluene, PM 2.5, among majority researched pollution sources (conventional cigarettes, waterpipe, incense, mosquito coils). The exposure to significantly higher pollution levels of benzene, toluene, and formaldehyde occurred in public environments, especially transport micro-environments. Such low levels of conventionally-assessed indoor pollutants resulting from the use of new nicotine containing products raise challenges for epidemiological studies of second-hand exposure to THS aerosol in real-life environments. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Comparative efficacy trial of cupping and serkangabin versus conventional therapy of migraine headaches: A randomized, open-label, comparative efficacy trial.

    PubMed

    Firoozabadi, Mohammad Dehghani; Navabzadeh, Maryam; Roudsari, Mohammad Khodashenas; Zahmatkash, Mohsen

    2014-12-01

    Migraine headaches are the most common acute and recurrent headaches. Current treatment of a migraine headache consists of multiple medications for control and prevention of recurrent attacks. Global emergence of alternative medicine led us to examine the efficacy of cupping therapy plus serkangabin syrup in the treatment of migraine headaches. This study was a randomized, controlled, open-label, comparative efficacy trial. We randomly assigned patients with migraine into cupping therapy plus serkangabin group (30 patients) and conventional treatment group (30 patients). An investigator assessed the severity of headache, frequency of attacks in a week and duration of attacks per hour in 5 visits (at the end of 2 weeks, 1, 3 and 6 months). Generalized estimating equations approach was used to analyze repeated measures data to compare outcomes in both groups. Average age for cupping therapy group and conventional treatment group were 31.7 (±7.6) and 32.6 (±12.7) years, respectively (P = 0.45). After treatment for 2 weeks; and 1, 3 and 6 months, severity of headache (P = 0.80), frequency of migraine attacks (P = 0.63) and duration of attacks per hours (P = 0.48) were similar in conventional and cupping groups but these symptoms were decreased in each group during the study (P < 0.001). There was no significant difference between cupping plus serkangabin therapy and conventional treatment in the treatment and prophylaxis of migraine. The alternative therapy may be used in cases of drug intolerance, no medication response, and in primary care.

  1. Comparative efficacy trial of cupping and serkangabin versus conventional therapy of migraine headaches: A randomized, open-label, comparative efficacy trial

    PubMed Central

    Firoozabadi, Mohammad Dehghani; Navabzadeh, Maryam; Roudsari, Mohammad Khodashenas; Zahmatkash, Mohsen

    2014-01-01

    Background: Migraine headaches are the most common acute and recurrent headaches. Current treatment of a migraine headache consists of multiple medications for control and prevention of recurrent attacks. Global emergence of alternative medicine led us to examine the efficacy of cupping therapy plus serkangabin syrup in the treatment of migraine headaches. Materials and Methods: This study was a randomized, controlled, open-label, comparative efficacy trial. We randomly assigned patients with migraine into cupping therapy plus serkangabin group (30 patients) and conventional treatment group (30 patients). An investigator assessed the severity of headache, frequency of attacks in a week and duration of attacks per hour in 5 visits (at the end of 2 weeks, 1, 3 and 6 months). Generalized estimating equations approach was used to analyze repeated measures data to compare outcomes in both groups. Results: Average age for cupping therapy group and conventional treatment group were 31.7 (±7.6) and 32.6 (±12.7) years, respectively (P = 0.45). After treatment for 2 weeks; and 1, 3 and 6 months, severity of headache (P = 0.80), frequency of migraine attacks (P = 0.63) and duration of attacks per hours (P = 0.48) were similar in conventional and cupping groups but these symptoms were decreased in each group during the study (P < 0.001). Conclusion: There was no significant difference between cupping plus serkangabin therapy and conventional treatment in the treatment and prophylaxis of migraine. The alternative therapy may be used in cases of drug intolerance, no medication response, and in primary care. PMID:25709653

  2. Evaluation of a patient specific femoral alignment guide for hip resurfacing.

    PubMed

    Olsen, Michael; Naudie, Douglas D; Edwards, Max R; Sellan, Michael E; McCalden, Richard W; Schemitsch, Emil H

    2014-03-01

    A novel alternative to conventional instrumentation for femoral component insertion in hip resurfacing is a patient specific, computed tomography based femoral alignment guide. A benchside study using cadaveric femora was performed comparing a custom alignment guide to conventional instrumentation and computer navigation. A clinical series of twenty-five hip resurfacings utilizing a custom alignment guide was conducted by three surgeons experienced in hip resurfacing. Using cadaveric femora, the custom guide was comparable to conventional instrumentation with computer navigation proving superior to both. Clinical femoral component alignment accuracy was 3.7° and measured within ± 5° of plan in 20 of 24 cases. Patient specific femoral alignment guides provide a satisfactory level of accuracy and may be a better alternative to conventional instrumentation for initial femoral guidewire placement in hip resurfacing. Crown Copyright © 2014. All rights reserved.

  3. Using atmospheric pressure plasma treatment for treating grey cotton fabric.

    PubMed

    Kan, Chi-Wai; Lam, Chui-Fung; Chan, Chee-Kooi; Ng, Sun-Pui

    2014-02-15

    Conventional wet treatment, desizing, scouring and bleaching, for grey cotton fabric involves the use of high water, chemical and energy consumption which may not be considered as a clean process. This study aims to investigate the efficiency of the atmospheric pressure plasma (APP) treatment on treating grey cotton fabric when compared with the conventional wet treatment. Grey cotton fabrics were treated with different combinations of plasma parameters with helium and oxygen gases and also through conventional desizing, scouring and bleaching processes in order to obtain comparable results. The results obtained from wicking and water drop tests showed that wettability of grey cotton fabrics was greatly improved after plasma treatment and yielded better results than conventional desizing and scouring. The weight reduction of plasma treated grey cotton fabrics revealed that plasma treatment can help remove sizing materials and impurities. Chemical and morphological changes in plasma treated samples were analysed by FTIR and SEM, respectively. Finally, dyeability of the plasma treated and conventional wet treated grey cotton fabrics was compared and the results showed that similar dyeing results were obtained. This can prove that plasma treatment would be another choice for treating grey cotton fabrics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Improved usability of a multi-infusion setup using a centralized control interface: A task-based usability test

    PubMed Central

    Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J.; Nijsten, Maarten W.

    2017-01-01

    The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface. PMID:28800617

  5. Improved usability of a multi-infusion setup using a centralized control interface: A task-based usability test.

    PubMed

    Doesburg, Frank; Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J; Nijsten, Maarten W

    2017-01-01

    The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface.

  6. Robotic hysterectomy versus conventional laparoscopic hysterectomy: outcome and cost analyses of a matched case-control study.

    PubMed

    Sarlos, Dimitri; Kots, Lavonne; Stevanovic, Nebojsa; Schaer, Gabriel

    2010-05-01

    Robotic surgery, with its technical advances, promises to open a new window to minimally invasive surgery in gynaecology. Feasibility and safety of this surgical innovation have been demonstrated in several studies, and now a critical analysis of these new developments regarding outcome and costs is in place. So far only a few studies compare robotic with conventional laparoscopic surgery in gynaecology. Our objective was to evaluate our initial experience performing total robot-assisted hysterectomy with the da Vinci surgical system and compare peri-operative outcome and costs with total laparoscopic hysterectomy. For this prospective matched case-control study at our institution, peri-operative data from our first 40 consecutive total robot-assisted hysterectomies for benign indications were recorded and matched 1:1 with total laparoscopic hysterectomies according to age, BMI and uterus weight. Surgical costs were calculated for both procedures. Surgeons' subjective impressions of robotics were evaluated with a self-developed questionnaire. No conversions to laparotomy or severe peri-operative complications occurred. Mean operating time was 109 (113; 50-170) min for the robotic group and 83 (80; 55-165) min for the conventional laparoscopic group. Mean postoperative hospitalisation for robotic surgery was 3.3 (3; 2-6) days versus 3.9 (4; 2-7) days for the conventional laparoscopic group. Average surgical cost of a robot-assisted laparoscopic hysterectomy was 4067 euros compared to 2151 euros for the conventional laparoscopic procedure at our institution. For the robotic group wider range of motion of the instruments and better ergonomics were considered to be an advantage, and lack of direct access to the patient was stated as a disadvantage. Robot-assited hysterectomy is a feasible and interesting new technique with comparable outcome to total laparoscopic hysterectomy. Operating times of total laparoscopic hysterectomy seem to be achieved quickly especially for experienced laparoscopic surgeons. However, costs of robotic surgery are still higher than for conventional laparoscopy. Randomised clinical trials need to be conducted to further evaluate benefits of this new technology for patients and surgeons and analyse its cost-effectiveness in gynaecology. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Respiratory protection during simulated emergency pediatric life support: a randomized, controlled, crossover study.

    PubMed

    Schumacher, Jan; Gray, Stuart A; Michel, Sophie; Alcock, Roger; Brinker, Andrea

    2013-02-01

    Emergency pediatric life support (EPLS) of children infected with transmissible respiratory diseases requires adequate respiratory protection for medical first responders. Conventional air-purifying respirators (APR) and modern loose-fitting powered air-purifying respirator-hoods (PAPR-hood) may have a different impact during pediatric resuscitation and therefore require evaluation. This study investigated the influence of APRs and PAPR-hoods during simulated pediatric cardiopulmonary resuscitation. Study design was a randomized, controlled, crossover study. Sixteen paramedics carried out a standardized EPLS scenario inside an ambulance, either unprotected (control) or wearing a conventional APR or a PAPR-hood. Treatment times and wearer comfort were determined and compared. All paramedics completed the treatment objectives of the study arms without adverse events. Study subjects reported that communication, dexterity and mobility were significantly better in the APR group, whereas the heat-build-up was significantly less in the PAPR-hood group. Treatment times compared to the control group did not significantly differ for the APR group but did with the PAPR-hood group (261±12 seconds for the controls, 275±9 seconds for the conventional APR and 286±13 seconds for the PAPR-hood group, P < .05. APRs showed a trend to better treatment times compared to PAPR-hoods during simulated pediatric cardiopulmonary resuscitation. Study participants rated mobility, ease of communication and dexterity with the tight-fitting APR system significantly better compared to the loose-fitting PAPR-hood.

  8. A comparative Thermal Analysis of conventional parabolic receiver tube and Cavity model tube in a Solar Parabolic Concentrator

    NASA Astrophysics Data System (ADS)

    Arumugam, S.; Ramakrishna, P.; Sangavi, S.

    2018-02-01

    Improvements in heating technology with solar energy is gaining focus, especially solar parabolic collectors. Solar heating in conventional parabolic collectors is done with the help of radiation concentration on receiver tubes. Conventional receiver tubes are open to atmosphere and loose heat by ambient air currents. In order to reduce the convection losses and also to improve the aperture area, we designed a tube with cavity. This study is a comparative performance behaviour of conventional tube and cavity model tube. The performance formulae were derived for the cavity model based on conventional model. Reduction in overall heat loss coefficient was observed for cavity model, though collector heat removal factor and collector efficiency were nearly same for both models. Improvement in efficiency was also observed in the cavity model’s performance. The approach towards the design of a cavity model tube as the receiver tube in solar parabolic collectors gave improved results and proved as a good consideration.

  9. Comparison of total oxidant/antioxidant status in unconjugated hyperbilirubinemia of newborn before and after conventional and LED phototherapy: A prospective randomized controlled trial.

    PubMed

    Demirel, Gamze; Uras, Nurdan; Celik, Istemi H; Aksoy, Hatice T; Oguz, Serife S; Erdeve, Omer; Erel, Ozcan; Dilmen, Ugur

    2010-10-01

    We evaluated and compared the oxidant and antioxidant status of hyperbilirubinemic infants before and after the two forms of phototherapy: conventional and LED phototherapy, in order to identify the optimal treatment method. Thirty newborns exposed to conventional (Group I) phototherapy and 30 infants exposed to LED phototherapy (Group II) were studied. The serum total antioxidant capacity (TAC) and the total oxidant status (TOS) were assessed by EREL's method. There were no statistically significant differences in TAC or TOS levels between Group I and Group II prior to phototherapy, and no statistically significant difference in TAC levels between the two groups after phototherapy; however, TOS levels were significantly lower in Group II compared to Group I after phototherapy. Oxidative stress index (OSI) increased after conventional phototherapy (p < 0.05) The increase in TOS following conventional phototherapy was not not observed following LED phototherapy. This difference should be considered when using phototherapy.

  10. A prospective single center study to assess the impact of surgical stabilization in patients with rib fracture.

    PubMed

    Khandelwal, Gaurav; Mathur, R K; Shukla, Sumit; Maheshwari, Ankur

    2011-01-01

    To compare the intensity of pain and duration of return to normal activity in patients with rib fractures treated with surgical stabilization with plating versus conventional treatment modalities. This study was conducted over a 12 month period. Patients with rib fractures were assessed by numerical pain scale. Patients having pain scale less than 5 were excluded from study. Patients having pain scale of 5 or more than 5 were treated with conventional treatment for next 10 days. On 11th day patients were again assessed by numerical pain scale and patients having score less than 5 were excluded from study. Patients having pain scale of 5, 6, and 7 were treated with conventional treatment and patients having pain scale of 8, 9, and 10 were selected for operative management. Operative and control group were compared on basis of intensity of pain and duration of return to normal activity. Follow up was done on 5, 15, and 30 post operative day. There was less pain in operative group as compared to control group. Mean rib fracture pain in operative group was 9.15, 2.31, 1.12 as compared to 6.25, 5.96, 4.50 in control group on 5, 15 and 30 post operative days. Also there was early return to normal activity in operative group. Surgical stabilization of rib fracture, an underutilized intervention is better than conventional conservative management in terms of both, decrease in intensity of pain and early return to normal activity. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  11. Comparison of methods for identifying causative bacterial microorganisms in presumed acute endophthalmitis: conventional culture, blood culture, and PCR.

    PubMed

    Pongsachareonnont, Pear; Honglertnapakul, Worawalun; Chatsuwan, Tanittha

    2017-02-21

    Identification of bacterial pathogens in endophthalmitis is important to inform antibiotic selection and treatment decisions. Hemoculture bottles and polymerase chain reaction (PCR) analysis have been proposed to offer good detection sensitivity. This study compared the sensitivity and accuracy of a blood culture system, a PCR approach, and conventional culture methods for identification of causative bacteria in cases of acute endophthalmitis. Twenty-nine patients with a diagnosis of presumed acute bacterial endophthalmitis who underwent vitreous specimen collection at King Chulalongkorn Memorial Hospital were enrolled in this study. Forty-one specimens were collected. Each specimen was divided into three parts, and each part was analyzed using one of three microbial identification techniques: conventional plate culture, blood culture, and polymerase chain reaction and sequencing. The results of the three methods were then compared. Bacteria were identified in 15 of the 41 specimens (36.5%). Five (12.2%) specimens were positive by conventional culture methods, 11 (26.8%) were positive by hemoculture, and 11 (26.8%) were positive by PCR. Cohen's kappa analysis revealed p-values for conventional methods vs. hemoculture, conventional methods vs. PCR, and hemoculture vs. PCR of 0.057, 0.33, and 0.009, respectively. Higher detection rates of Enterococcus faecalis were observed for hemoculture and PCR than for conventional methods. Blood culture bottles and PCR detection may facilitate bacterial identification in cases of presumed acute endophthalmitis. These techniques should be used in addition to conventional plate culture methods because they provide a greater degree of sensitivity than conventional plate culture alone for the detection of specific microorganisms such as E. faecalis. Thai Clinical Trial Register No. TCTR20110000024 .

  12. Differences in energy expenditure for conventional and femtosecond-assisted cataract surgery using 2 different phacoemulsification systems.

    PubMed

    Yesilirmak, Nilufer; Diakonis, Vasilios F; Sise, Adam; Waren, Daniel P; Yoo, Sonia H; Donaldson, Kendall E

    2017-01-01

    To compare the mean cumulative dissipated energy (CDE) in patients having femtosecond laser-assisted or conventional phacoemulsification cataract surgery using 2 different phacoemulsification platforms. Bascom Palmer Eye Institute, Miami, Florida, USA. Prospective comparative nonrandomized clinical study. Consecutive patients were scheduled to have femtosecond laser-assisted cataract surgery with the Lensx laser or conventional phacoemulsification using an active-fluidics torsional platform (Centurion) or torsional platform (Infiniti). The mean CDE and cataract grade were recorded. The study comprised 570 eyes (570 patients). There was no statistically significant difference in mean age (P = .41, femtosecond group; P = .33, conventional group) or cataract grade (P = .78 and P = .45, respectively) between the active-fluidics and gravity-fluidics platforms. In femtosecond cases (145 eyes), the mean CDE (percent-seconds) was 5.18 ± 4.58 (SD) with active fluidics and 7.00 ± 6.85 with gravity fluidics; in conventional cases (425 eyes), the mean CDE was 7.77 ± 6.97 and 11.43 ± 9.12, respectively. In both femtosecond cases and conventional cases, the CDE was lower with the active-fluidics platform than with the gravity-fluidics platform (P = .029, femtosecond group; P < .001 conventional group). With both fluidics platforms, the mean CDE was significantly lower in the femtosecond group than in the conventional group (both P < .001). The active-fluidics phacoemulsification platform achieved lower CDE values than the gravity-fluidics platform for conventional cataract extraction. Femtosecond laser pretreatment with the active-fluidics platform further reduced CDE. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Hydraulic Hybrid and Conventional Parcel Delivery Vehicles' Measured Laboratory Fuel Economy on Targeted Drive Cycles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammert, M. P.; Burton, J.; Sindler, P.

    2014-10-01

    This research project compares laboratory-measured fuel economy of a medium-duty diesel powered hydraulic hybrid vehicle drivetrain to both a conventional diesel drivetrain and a conventional gasoline drivetrain in a typical commercial parcel delivery application. Vehicles in this study included a model year 2012 Freightliner P100H hybrid compared to a 2012 conventional gasoline P100 and a 2012 conventional diesel parcel delivery van of similar specifications. Drive cycle analysis of 484 days of hybrid parcel delivery van commercial operation from multiple vehicles was used to select three standard laboratory drive cycles as well as to create a custom representative cycle. These fourmore » cycles encompass and bracket the range of real world in-use data observed in Baltimore United Parcel Service operations. The NY Composite cycle, the City Suburban Heavy Vehicle Cycle cycle, and the California Air Resources Board Heavy Heavy-Duty Diesel Truck (HHDDT) cycle as well as a custom Baltimore parcel delivery cycle were tested at the National Renewable Energy Laboratory's Renewable Fuels and Lubricants Laboratory. Fuel consumption was measured and analyzed for all three vehicles. Vehicle laboratory results are compared on the basis of fuel economy. The hydraulic hybrid parcel delivery van demonstrated 19%-52% better fuel economy than the conventional diesel parcel delivery van and 30%-56% better fuel economy than the conventional gasoline parcel delivery van on cycles other than the highway-oriented HHDDT cycle.« less

  14. A comparison of piezosurgery with conventional techniques for internal osteotomy.

    PubMed

    Koçak, I; Doğan, R; Gökler, O

    2017-06-01

    To compare conventional osteotomy with the piezosurgery medical device, in terms of postoperative edema, ecchymosis, pain, operation time, and mucosal integrity, in rhinoplasty patients. In this prospective study, 49 rhinoplasty patients were randomly divided into two groups according to osteotomy technique used, either conventional osteotomy or piezosurgery. For all patients, the total duration of the operation was recorded, and photographs were taken and scored for ecchymosis and edema on postoperative days 2, 4, and 7. In addition, pain level was evaluated on postoperative day 2, and mucosal integrity was assessed on day 4. All scoring and evaluation was conducted by a physician who was blinded to the osteotomy procedure. In the piezosurgery group, edema scores on postoperative day 2 and ecchymosis scores on postoperative days 2, 4, and 7 were significantly lower than in the conventional osteotomy group (p < 0.05). On postoperative day 2, the pain level was lower in the piezosurgery group than in the conventional osteotomy group (p < 0.05). In an endoscopic examination on postoperative day 4, while 24% of the patients in the conventional osteotomy group had mucosal damage, no such damage was observed in the piezosurgery group. When total operation duration was compared, there was no significant difference between the groups (p > 0.05). Piezosurgery is a safe osteotomy method, with less edema (in the early postoperative period) and ecchymosis compared with conventional osteotomy, as well as less pain, a similar operation duration, and no mucosal damage.

  15. Percutaneous laser disc decompression versus conventional microdiscectomy in sciatica: a randomized controlled trial.

    PubMed

    Brouwer, Patrick A; Brand, Ronald; van den Akker-van Marle, M Elske; Jacobs, Wilco C H; Schenk, Barry; van den Berg-Huijsmans, Annette A; Koes, Bart W; van Buchem, M A; Arts, Mark P; Peul, Wilco C

    2015-05-01

    Percutaneous laser disc decompression (PLDD) is a minimally invasive treatment for lumbar disc herniation, with Food and Drug Administration approval since 1991. However, no randomized trial comparing PLDD to conventional treatment has been performed. In this trial, we assessed the effectiveness of a strategy of PLDD as compared with conventional surgery. This randomized prospective trial with a noninferiority design was carried out in two academic and six teaching hospitals in the Netherlands according to an intent-to-treat protocol with full institutional review board approval. One hundred fifteen eligible surgical candidates, with sciatica from a disc herniation smaller than one-third of the spinal canal, were included. The main outcome measures for this trial were the Roland-Morris Disability Questionnaire for sciatica, visual analog scores for back and leg pain, and the patient's report of perceived recovery. Patients were randomly allocated to PLDD (n=57) or conventional surgery (n=58). Blinding was impossible because of the nature of the interventions. This study was funded by the Healthcare Insurance Board of the Netherlands. The primary outcome, Roland-Morris Disability Questionnaire, showed noninferiority of PLDD at 8 (-0.1; [95% confidence interval (CI), -2.3 to 2.1]) and 52 weeks (-1.1; 95% CI, -3.4 to 1.1) compared with conventional surgery. There was, however, a higher speed of recovery in favor of conventional surgery (hazard ratio, 0.64 [95% CI, 0.42-0.97]). The number of reoperations was significantly less in the conventional surgery group (38% vs. 16%). Overall, a strategy of PLDD, with delayed surgery if needed, resulted in noninferior outcomes at 1 year. At 1 year, a strategy of PLDD, followed by surgery if needed, resulted in noninferior outcomes compared with surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Short daily-, nocturnal- and conventional-home hemodialysis have similar patient and treatment survival.

    PubMed

    Tennankore, Karthik K; Na, Yingbo; Wald, Ron; Chan, Christopher T; Perl, Jeffrey

    2018-01-01

    Home hemodialysis (HHD) has many benefits, but less is known about relative outcomes when comparing different home-based hemodialysis modalities. Here, we compare patient and treatment survival for patients receiving short daily HHD (2-3 hours/5 plus sessions per week), nocturnal HHD (6-8 hours/5 plus sessions per week) and conventional HHD (3-6 hours/2-4 sessions per week). A nationally representative cohort of Canadian HHD patients from 1996-2012 was studied. The primary outcome was death or treatment failure (defined as a permanent return to in-center hemodialysis or peritoneal dialysis) using an intention to treat analysis and death-censored treatment failure as a secondary outcome. The cohort consisted of 600, 508 and 202 patients receiving conventional, nocturnal, and short daily HHD, respectively. Conventional-HHD patients were more likely to use dialysis catheter access (43%) versus nocturnal or short daily HHD (32% and 31%, respectively). Although point estimates were in favor of both therapies, after multivariable adjustment for patient and center factors, there was no statistically significant reduction in the relative hazard for the death/treatment failure composite comparing nocturnal to conventional HHD (hazard ratio 0.83 [95% confidence interval 0.66-1.03]) or short daily to conventional HHD (0.84, 0.63-1.12). Among those with information on vascular access, patients receiving nocturnal HHD had a relative improvement in death-censored treatment survival (0.75, 0.57-0.98). Thus, in this national cohort of HHD patients, those receiving short daily and nocturnal HHD had similar patient/treatment survival compared with patients receiving conventional HHD. Copyright © 2017 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  17. The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study.

    PubMed

    Awad, Manal A; Rashid, Faahim; Feine, Jocelyne S

    2014-01-01

    To determine the difference in oral health-related quality of life (OHRQoL) in patients who received mandibular 2-implant overdentures and conventional dentures in a pragmatic international study. In this prospective study, data were gathered from 203 edentulous patients (mean age, 68.8; SD: 10.4 years) at eight centres in North America, South America and Europe. The patients were provided with new mandibular conventional dentures or implant overdentures supported by 2 implants and ball attachments and opposed by conventional dentures. At baseline and at 6 months post-treatment, patients rated their oral health-related quality of life using the OHIP-20. A significantly higher proportion of the participants in the implant group in North America reported improvement in both the psychological and the handicap domains, compared to those who received conventional dentures (93% vs. 52%; P < 0.05). In South America, 100% of participants who received implant overdentures reported improvement in physical pain, compared to 66% in the conventional group (P < 0.05). Differences in mean change scores among those who expressed improvement were not significantly different between sites or treatments. Mandibular 2-implant overdentures are more likely than conventional dentures to improve OHRQL for edentulous patients. Cultural differences were also observed in the impact of implant overdentures on the different domains of the OHIP-20. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Comparison of Bolton analysis and Little’s irregularity index on laser scanned three-dimensional digital study models with conventional study models

    NASA Astrophysics Data System (ADS)

    Kurnia, H.; Noerhadi, N. A. I.

    2017-08-01

    Three-dimensional digital study models were introduced following advances in digital technology. This study was carried out to assess the reliability of digital study models scanned by a laser scanning device newly assembled. The aim of this study was to compare the digital study models and conventional models. Twelve sets of dental impressions were taken from patients with mild-to-moderate crowding. The impressions were taken twice, one with alginate and the other with polyvinylsiloxane. The alginate impressions were made into conventional models, and the polyvinylsiloxane impressions were scanned to produce digital models. The mesiodistal tooth width and Little’s irregularity index (LII) were measured manually with digital calipers on the conventional models and digitally on the digital study models. Bolton analysis was performed on each study models. Each method was carried out twice to check for intra-observer variability. The reproducibility (comparison of the methods) was assessed using independent-sample t-tests. The mesiodistal tooth width between conventional and digital models did not significantly differ (p > 0.05). Independent-sample t-tests did not identify statistically significant differences for Bolton analysis and LII (p = 0.603 for Bolton and p = 0894 for LII). The measurements of the digital study models are as accurate as those of the conventional models.

  19. A Meta-Analysis of Individualized Instruction in Dental Education.

    ERIC Educational Resources Information Center

    Dacanay, Lakshmi S; Cohen, Peter A.

    1992-01-01

    Meta-analysis of 34 comparative studies on conventional vs. individualized instruction (II) found most favored the latter but with small-moderate overall effect. Pacing had significant effect, with teacher-pacing more effective than student-paced learning. On average, II required less time than conventional teaching. Additional research on this…

  20. Custodiol for myocardial protection and preservation: a systematic review

    PubMed Central

    Seco, Michael; Dunne, Ben; Matzelle, Shannon J.; Murphy, Michelle; Joshi, Pragnesh; Yan, Tristan D.; Wilson, Michael K.; Bannon, Paul G.; Vallely, Michael P.; Passage, Jurgen

    2013-01-01

    Introduction Custodiol cardioplegia is attractive for minimally invasive cardiac surgery, as a single dose provides a long period of myocardial protection. Despite widespread use in Europe, there is little data confirming its efficacy compared with conventional (blood or crystalloid) cardioplegia. There is similar enthusiasm for its use in organ preservation for transplant, but also a lack of data. This systematic review aimed to assess the evidence for the efficacy of Custodiol in myocardial protection and as a preservation solution in heart transplant. Methods Electronic searches were performed of six databases from inception to October 2013. Reviewers independently identified studies that compared Custodiol with conventional cardioplegia (blood or extracellular crystalloid) in adult patients for meta-analysis; large case series that reported results using Custodiol were analyzed. Next, we identified studies that compared Custodiol with other organ preservation solutions for organ preservation in heart transplant. Results Fourteen studies compared Custodiol with conventional cardioplegia for myocardial protection in adult cardiac surgery. No difference was identified in mortality; there was a trend for increased incidence of ventricular fibrillation in the Custodiol group that did not reach statistical significance. No difference was identified in studies that compared Custodiol with other solutions for heart transplant. Conclusions Despite widespread clinical use, the evidence supporting the superiority of Custodiol over other solutions for myocardial protection or organ preservation is limited. Large randomised trials are required. PMID:24349972

  1. The Ultimate Pile Bearing Capacity from Conventional and Spectral Analysis of Surface Wave (SASW) Measurements

    NASA Astrophysics Data System (ADS)

    Faizah Bawadi, Nor; Anuar, Shamilah; Rahim, Mustaqqim A.; Mansor, A. Faizal

    2018-03-01

    A conventional and seismic method for determining the ultimate pile bearing capacity was proposed and compared. The Spectral Analysis of Surface Wave (SASW) method is one of the non-destructive seismic techniques that do not require drilling and sampling of soils, was used in the determination of shear wave velocity (Vs) and damping (D) profile of soil. The soil strength was found to be directly proportional to the Vs and its value has been successfully applied to obtain shallow bearing capacity empirically. A method is proposed in this study to determine the pile bearing capacity using Vs and D measurements for the design of pile and also as an alternative method to verify the bearing capacity from the other conventional methods of evaluation. The objectives of this study are to determine Vs and D profile through frequency response data from SASW measurements and to compare pile bearing capacities obtained from the method carried out and conventional methods. All SASW test arrays were conducted near the borehole and location of conventional pile load tests. In obtaining skin and end bearing pile resistance, the Hardin and Drnevich equation has been used with reference strains obtained from the method proposed by Abbiss. Back analysis results of pile bearing capacities from SASW were found to be 18981 kN and 4947 kN compared to 18014 kN and 4633 kN of IPLT with differences of 5% and 6% for Damansara and Kuala Lumpur test sites, respectively. The results of this study indicate that the seismic method proposed in this study has the potential to be used in estimating the pile bearing capacity.

  2. Teaching Dental Students to Understand the Temporomandibular Joint Using MRI: Comparison of Conventional and Digital Learning Methods.

    PubMed

    Arús, Nádia A; da Silva, Átila M; Duarte, Rogério; da Silveira, Priscila F; Vizzotto, Mariana B; da Silveira, Heraldo L D; da Silveira, Heloisa E D

    2017-06-01

    The aims of this study were to evaluate and compare the performance of dental students in interpreting the temporomandibular joint (TMJ) with magnetic resonance imaging (MRI) scans using two learning methods (conventional and digital interactive learning) and to examine the usability of the digital learning object (DLO). The DLO consisted of tutorials about MRI and anatomic and functional aspects of the TMJ. In 2014, dental students in their final year of study who were enrolled in the elective "MRI Interpretation of the TMJ" course comprised the study sample. After exclusions for nonattendance and other reasons, 29 of the initial 37 students participated in the study, for a participation rate of 78%. The participants were divided into two groups: a digital interactive learning group (n=14) and a conventional learning group (n=15). Both methods were assessed by an objective test applied before and after training and classes. Aspects such as support and training requirements, complexity, and consistency of the DLO were also evaluated using the System Usability Scale (SUS). A significant between-group difference in the posttest results was found, with the conventional learning group scoring better than the DLO group, indicated by mean scores of 9.20 and 8.11, respectively, out of 10. However, when the pretest and posttest results were compared, both groups showed significantly improved performance. The SUS score was 89, which represented a high acceptance of the DLO by the users. The students who used the conventional method of learning showed superior performance in interpreting the TMJ using MRI compared to the group that used digital interactive learning.

  3. Comparative study between laser and conventional techniques for class V cavity preparation in gamma-irradiated teeth (in vitro study).

    PubMed

    Rasmy, Amr H M; Harhash, Tarek A; Ghali, Rami M S; El Maghraby, Eman M F; El Rouby, Dalia H

    2017-01-01

    The purpose of this study was to compare laser with conventional techniques in class V cavity preparation in gamma-irradiated teeth. Forty extracted human teeth with no carious lesions were used for this study and were divided into two main groups: Group I (n = 20) was not subjected to gamma radiation (control) and Group II (n=20) was subjected to gamma radiation of 60 Gray. Standard class V preparation was performed in buccal and lingual sides of each tooth in both groups. Buccal surfaces were prepared by the Er,Cr:YSGG laser (Waterlase iPlus) 2780 nm, using the gold handpiece with MZ10 Tip in non-contact and the "H" mode, following parameters of cavity preparation - power 6 W, frequency 50 Hz, 90% water and 70% air, then shifting to surface treatment laser parameters - power 4.5 W, frequency 50 Hz, 80% water and 50% air. Lingual surfaces were prepared by the conventional high-speed turbine using round diamond bur. Teeth were then sectioned mesio-distally, resulting in 80 specimens: 40 of which were buccal laser-treated (20 control and 20 gamma-irradiated specimens) and 40 were lingual conventional high-speed bur specimens (20 control and 20 gamma-irradiated specimens). Microleakage analysis revealed higher scores in both gamma groups compared with control groups. Chi-square test revealed no significant difference between both control groups and gamma groups (p=1, 0.819, respectively). A significant difference was revealed between all 4 groups (p=0.00018). Both laser and conventional high-speed turbine bur show good bond strength in control (non-gamma) group, while microleakage is evident in gamma group, indicating that gamma radiation had a dramatic negative effect on the bond strength in both laser and bur-treated teeth.

  4. Seat Integrated and Conventional Restraints: A Study of Crash Injury/Fatality Rates in Rollovers

    PubMed Central

    Padmanaban, Jeya; Burnett, Roger A.

    2008-01-01

    This study used police-reported motor vehicle crash data from eleven states to determine ejection, fatality, and fatal/serious injury risks for belted drivers in vehicles with conventional seatbelts compared to belted drivers in vehicles with seat integrated restraint systems (SIRS). Risks were compared for 11,159 belted drivers involved in single- or multiple-vehicle rollover crashes. Simple driver ejection (partial and complete), fatality, and injury rates were derived, and logistic regression analyses were used to determine relative contribution of factors (including event calendar year, vehicle age, driver age/gender/alcohol use) that significantly influence the likelihood of fatality and fatal/serious injury to belted drivers in rollovers. Results show no statistically significant difference in driver ejection, fatality, or fatal/serious injury rates between vehicles with conventional belts and vehicles with SIRS. PMID:19026243

  5. Usefulness of the automatic quantitative estimation tool for cerebral blood flow: clinical assessment of the application software tool AQCEL.

    PubMed

    Momose, Mitsuhiro; Takaki, Akihiro; Matsushita, Tsuyoshi; Yanagisawa, Shin; Yano, Kesato; Miyasaka, Tadashi; Ogura, Yuka; Kadoya, Masumi

    2011-01-01

    AQCEL enables automatic reconstruction of single-photon emission computed tomogram (SPECT) without image degradation and quantitative analysis of cerebral blood flow (CBF) after the input of simple parameters. We ascertained the usefulness and quality of images obtained by the application software AQCEL in clinical practice. Twelve patients underwent brain perfusion SPECT using technetium-99m ethyl cysteinate dimer at rest and after acetazolamide (ACZ) loading. Images reconstructed using AQCEL were compared with those reconstructed using conventional filtered back projection (FBP) method for qualitative estimation. Two experienced nuclear medicine physicians interpreted the image quality using the following visual scores: 0, same; 1, slightly superior; 2, superior. For quantitative estimation, the mean CBF values of the normal hemisphere of the 12 patients using ACZ calculated by the AQCEL method were compared with those calculated by the conventional method. The CBF values of the 24 regions of the 3-dimensional stereotaxic region of interest template (3DSRT) calculated by the AQCEL method at rest and after ACZ loading were compared to those calculated by the conventional method. No significant qualitative difference was observed between the AQCEL and conventional FBP methods in the rest study. The average score by the AQCEL method was 0.25 ± 0.45 and that by the conventional method was 0.17 ± 0.39 (P = 0.34). There was a significant qualitative difference between the AQCEL and conventional methods in the ACZ loading study. The average score for AQCEL was 0.83 ± 0.58 and that for the conventional method was 0.08 ± 0.29 (P = 0.003). During quantitative estimation using ACZ, the mean CBF values of 12 patients calculated by the AQCEL method were 3-8% higher than those calculated by the conventional method. The square of the correlation coefficient between these methods was 0.995. While comparing the 24 3DSRT regions of 12 patients, the squares of the correlation coefficient between AQCEL and conventional methods were 0.973 and 0.986 for the normal and affected sides at rest, respectively, and 0.977 and 0.984 for the normal and affected sides after ACZ loading, respectively. The quality of images reconstructed using the application software AQCEL were superior to that obtained using conventional method after ACZ loading, and high correlations were shown in quantity at rest and after ACZ loading. This software can be applied to clinical practice and is a useful tool for improvement of reproducibility and throughput.

  6. WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozguner, O; Halliburton, S; Dhanantwari, A

    2016-06-15

    Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation frommore » water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.« less

  7. Comparison of Conventional and Microwave Treatment on Soymilk for Inactivation of Trypsin Inhibitors and In Vitro Protein Digestibility

    PubMed Central

    Vagadia, Brinda Harish; Raghavan, Vijaya

    2018-01-01

    Soymilk is lower in calories compared to cow’s milk, since it is derived from a plant source (no cholesterol) and is an excellent source of protein. Despite the beneficial factors, soymilk is considered as one of the most controversial foods in the world. It contains serine protease inhibitors which lower its nutritional value and digestibility. Processing techniques for the elimination of trypsin inhibitors and lipoxygenase, which have shorter processing time and lower production costs are required for the large-scale manufacturing of soymilk. In this study, the suitable conditions of time and temperature are optimized during microwave processing to obtain soymilk with maximum digestibility with inactivation of trypsin inhibitors, in comparison to the conventional thermal treatment. The microwave processing conditions at a frequency of 2.45 GHz and temperatures of 70 °C, 85 °C and 100 °C for 2, 5 and 8 min were investigated and were compared to conventional thermal treatments at the same temperature for 10, 20 and 30 min. Response surface methodology is used to design and optimize the experimental conditions. Thermal processing was able to increase digestibility by 7% (microwave) and 11% (conventional) compared to control, while trypsin inhibitor activity reduced to 1% in microwave processing and 3% in conventional thermal treatment when compared to 10% in raw soybean. PMID:29316679

  8. Combining of ETHOS Operating Ergonomic Platform, Three-dimensional Laparoscopic Camera, and Radius Surgical System Manipulators Improves Ergonomy in Urologic Laparoscopy: Comparison with Conventional Laparoscopy and da Vinci in a Pelvi Trainer.

    PubMed

    Tokas, Theodoros; Gözen, Ali Serdar; Avgeris, Margaritis; Tschada, Alexandra; Fiedler, Marcel; Klein, Jan; Rassweiler, Jens

    2017-10-01

    Posture, vision, and instrumentation limitations are the main predicaments of conventional laparoscopy. To combine the ETHOS surgical chair, the three-dimensional laparoscope, and the Radius Surgical System manipulators, and compare the system with conventional laparoscopy and da Vinci in terms of task completion times and discomfort. Fifteen trainees performed the three main laparoscopic suturing tasks of the Heilbronn training program (IV: simulation of dorsal venous complex suturing; V: circular suturing of tubular structure; and VI: urethrovesical anastomosis) in a pelvi trainer. The tasks were performed conventionally, utilizing the three devices, and robotically. Task completion times were recorded and the surgeon discomfort was evaluated using questionnaires. Task completion times were compared using nonparametric Wilcoxon signed rank test and ergonomic scores were compared using Pearson chi-square test. The use of the full laparoscopic set (ETHOS chair, three-dimensional laparoscopic camera, Radius Surgical System needle holders), resulted in a significant improvement of the completion time of the three tested tasks compared with conventional laparoscopy (p<0.001) and similar to da Vinci surgery. After completing Tasks IV, V, and VI conventionally, 12 (80%), 13 (86.7%), and 13 (86.7%) of the 15 trainees, respectively, reported heavy total discomfort. The full laparoscopic system nullified heavy discomfort for Tasks IV and V and minimized it (6.7%) for the most demanding Task VI. Especially for Task VI, all trainees gained benefit, by using the system, in terms of task completion times and discomfort. The limited trainee robotic experience and the questionnaire subjectivity could be a potential limitation. The ergonomic laparoscopic system offers significantly improved task completion times and ergonomy than conventional laparoscopy. Furthermore, it demonstrates comparable results to robotic surgery. The study was conducted in a pelvi trainer and no patients were recruited. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  9. Comparative performance of conventional OPC concrete and HPC designed by densified mixture design algorithm

    NASA Astrophysics Data System (ADS)

    Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti

    2017-12-01

    This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.

  10. Conventional forceps or hot biopsy: comparative study of two methods in diagnosis of endobronchial lesions.

    PubMed

    Jabbari, Hamidreza; Fakhri, Mohammad; Lotfaliani, Mojtaba; Kiani, Arda

    2013-01-01

    It is suggested that hot electrocoagulation-enabled forceps (hot biopsy) may reduce hemorrhage risk after the biopsy in endobronchial tumors. The main concern in this method is possible reduction of the specimen's quality. To compare the procedure related hemorrhage with hot biopsy and conventional forceps biopsy and the diagnostic quality of the obtained specimens with either technique. In this prospective study, assessment of the biopsy samples and quantity of hemorrhage were done in a blind fashion. At first, for each patient a definite clinical diagnosis was made based on pathologic examination of all available samples, clinical data, and imaging findings. Then, second pathologist reviewed all samples to evaluate the quality of the samples. A total of 36 patients with endobronchial lesions were included in this study. Definite diagnosis was made in 83% of the patients. Diagnostic yield of the two methods were not statistically different, while the mean hemorrhage grades of all hot biopsy protocols were significantly lower as compared to that of conventional biopsy (p=0.003, p<0.001 and p<0.001 for 10,20and40 voltages respectively). No significant difference was detected between the qualities of specimens obtained by hot biopsy methods in comparison with conventional biopsy (p>0.05 for all three voltages). Hot biopsy can be a valuable alternative to forceps biopsy in evaluating endobronchial lesions.

  11. Treatment of localized gingival recession using the free rotated papilla autograft combined with coronally advanced flap by conventional (macrosurgery) and surgery under magnification (microsurgical) technique: A comparative clinical study

    PubMed Central

    Pandey, Suraj; Mehta, D. S.

    2013-01-01

    Background: The aim of the present study was to evaluate and compare the conventional (macro-surgical) and microsurgical approach in performing the free rotated papilla autograft combined with coronally advanced flap surgery in treatment of localized gingival recession. Materials and Methods: A total of 20 sites from 10 systemically healthy patients were selected for the study. The selected sites were randomly divided into experimental site A and experimental site B by using the spilt mouth design. Conventional (macro-surgical) approach for site A and micro-surgery for site B was applied in performing the free rotated papilla autograft combined with coronally advanced flap. Recession depth (RD), recession width (RW) clinical attachment level (CAL.) and width of keratinized tissue (WKT.) were recorded at baseline, 3 months and 6 months post-operatively. Results: Both (macro- and microsurgery) groups showed significant clinical improvement in all the parameters (RD, RW, CAL and WKT). However, on comparing both the groups, these parameters did not reach statistical significance. Conclusion: Both the surgical procedures were equally effective in treatment of localized gingival recession by the free rotated papilla autograft technique combined with coronally advanced flap. However, surgery under magnification (microsurgery) may be clinically better than conventional surgery in terms of less post-operative pain and discomfort experienced by patients at the microsurgical site. PMID:24554888

  12. Antimicrobial susceptibility of foodborne pathogens in organic or natural production systems: an overview.

    PubMed

    Jacob, Megan E; Fox, James Trent; Reinstein, Shelby L; Nagaraja, T G

    2008-12-01

    Organic and natural food production systems are increasing in popularity, at least partially because consumers perceive that these niche markets provide healthier and safer food products. One major difference between these niche markets and conventional production systems is the use of antimicrobials. Because antimicrobial agents exert selective pressures for antimicrobial resistance, relating antimicrobial susceptibility of foodborne bacteria to niche market production systems is of interest. Other differences between production systems might also influence the susceptibility of foodborne pathogens. The objective of this review is to compare the impact of food animal production systems on the antimicrobial susceptibility of common foodborne bacterial pathogens. Studies comparing the susceptibility of such pathogens were diverse in terms of geographic location, procedures, species of bacteria, and antimicrobials evaluated; thus, it was difficult to draw conclusions. The literature is highly variable in terms of production type and practices and susceptibility associations, although few studies have compared truly organic and conventional practices. When statistical associations were found between production type and minimum inhibitory concentrations or percentage of isolates resistant for a particular pathogen, the isolates from conventionally reared animals/products were more commonly resistant than the comparison group (organic, antibiotic free, etc.). Therefore, further studies are needed to better assess public health consequences of antimicrobial resistance and food animal production systems, specifically organic or natural versus conventional.

  13. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty.

    PubMed

    Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J

    2018-01-01

    Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.

  14. Dosimetric quality endpoints for low-dose-rate prostate brachytherapy using biological effective dose (bed) vs. conventional dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Rachana; Al-Hallaq, Hania; Pelizzari, Charles A.

    2003-12-31

    The purpose of this study was to compare conventional low-dose-rate prostate brachytherapy dosimetric quality parameters with their biological effective dose (BED) counterparts. To validate a model for transformation from conventional dose to BED, the postimplant plans of 31 prostate brachytherapy patients were evaluated using conventional dose-volume histogram (DVH) quality endpoints and analogous BED-DVH endpoints. Based on CT scans obtained 4 weeks after implantation, DVHs were computed and standard dosimetric endpoints V100 (volume receiving 100% of the prescribed dose), V150, V200, HI (1-[V150/V100]), and D90 (dose that 90% of the target volume received) were obtained for quality analysis. Using known andmore » reported transformations, dose grids were transformed to BED-early ({alpha}/{beta} = 10 Gy) and BED-late ({alpha}/{beta} = 3 Gy) grids, and the same dosimetric endpoints were analyzed. For conventional, BED-early and BED-late DVHs, no differences in V100 were seen (0.896, 0.893, and 0.894, respectively). However, V150 and V200 were significantly higher for both BED-early (0.582 and 0.316) and BED-late (0.595 and 0.337), compared with the conventional (0.539 and 0.255) DVHs. D90 was significantly lower for the BED-early (103.1 Gy) and BED-late transformations (106.9 Gy) as compared with the conventional (119.5 Gy) DVHs. The conventional prescription parameter V100 is the same for the corresponding BED-early and BED-late transformed DVHs. The toxicity parameters V150 and V200 are slightly higher using the BED transformations, suggesting that the BED doses are somewhat higher than predicted using conventional DVHs. The prescription/quality parameter D90 is slightly lower, implying that target coverage is lower than predicted using conventional DVHs. This methodology can be applied to analyze BED dosimetric endpoints to improve clinical outcome and reduce complications of prostate brachytherapy.« less

  15. Tube thoracostomy training with a medical simulator is associated with faster, more successful performance of the procedure

    PubMed Central

    Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Chung, Hyun Soo

    2016-01-01

    Objective Tube thoracostomy (TT) is a commonly performed intensive care procedure. Simulator training may be a good alternative method for TT training, compared with conventional methods such as apprenticeship and animal skills laboratory. However, there is insufficient evidence supporting use of a simulator. The aim of this study is to determine whether training with medical simulator is associated with faster TT process, compared to conventional training without simulator. Methods This is a simulation study. Eligible participants were emergency medicine residents with very few (≤3 times) TT experience. Participants were randomized to two groups: the conventional training group, and the simulator training group. While the simulator training group used the simulator to train TT, the conventional training group watched the instructor performing TT on a cadaver. After training, all participants performed a TT on a cadaver. The performance quality was measured as correct placement and time delay. Subjects were graded if they had difficulty on process. Results Estimated median procedure time was 228 seconds in the conventional training group and 75 seconds in the simulator training group, with statistical significance (P=0.040). The difficulty grading did not show any significant difference among groups (overall performance scale, 2 vs. 3; P=0.094). Conclusion Tube thoracostomy training with a medical simulator, when compared to no simulator training, is associated with a significantly faster procedure, when performed on a human cadaver. PMID:27752610

  16. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    PubMed

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  17. Comparison of patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures: A preliminary study.

    PubMed

    Omura, Yuri; Kanazawa, Manabu; Sato, Daisuke; Kasugai, Shohei; Minakuchi, Shunsuke

    2016-07-01

    The aim of this preliminary study is to compare patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures retained by magnetic attachments. Nineteen participants with edentulous mandibles were randomly assigned into either an immediate loading group (immediate group) or a conventional loading group (conventional group). Each participant received 2 implants in the inter-foraminal region by means of flapless surgery. Prostheses in the immediate and conventional groups were loaded using magnetic attachments on the same day as implant placement or 3 months after surgery, respectively. All participants completed questionnaires (the Japanese version of the Oral Health Impact Profile for edentulous [OHIP-EDENT-J], the patient's denture assessment [PDA], and general satisfaction) before implant placement (baseline) and 1, 2, 3, 4, 5, 6, and 12 months after surgery. The median differences between baseline and each monthly score were compared using the Mann-Whitney U test. The differences in median and 95% confidence interval between two groups were analyzed. The immediate group showed slightly lower OHIP-EDENT-J summary score at 1 and 3 months than the conventional group (P=0.09). In the lower denture domain of PDA, the immediate group showed a statistically higher score at 3 months (P=0.04). There was no statistically significant difference in general satisfaction between the two groups. Based on this preliminary study, immediate loading of mandibular two-implant overdentures with magnetic attachments tends to improve oral health-related quality of life and patient assessment earlier than observed with a conventional loading protocol. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Extended-hours hemodialysis is associated with lower mortality risk in patients with end-stage renal disease

    PubMed Central

    Rivara, Matthew B.; Adams, Scott V.; Kuttykrishnan, Sooraj; Kalantar-Zadeh, Kamyar; Arah, Onyebuchi A.; Cheung, Alfred K.; Katz, Ronit; Molnar, Miklos Z.; Ravel, Vanessa; Soohoo, Melissa; Streja, Elani; Himmelfarb, Jonathan; Mehrotra, Rajnish

    2016-01-01

    Extended-hours hemodialysis offers substantially longer treatment time compared to conventional hemodialysis schedules and is associated with improved fluid and electrolyte control and favorable cardiac remodeling. However, whether extended-hours hemodialysis improves survival remains unclear. Therefore, we determined the association between extended-hours compared to conventional hemodialysis and the risk of all-cause mortality in a nationally representative cohort of patients initiating maintenance dialysis in the United States from 2007 to 2011. Survival analyses using causal inference modeling with marginal structural models were performed to compare mortality risk among 1,206 individuals undergoing thrice weekly extended-hours hemodialysis or 111,707 patients receiving conventional hemodialysis treatments. The average treatment time per session for extended-hours hemodialysis was 399 minutes compared to 211 minutes for conventional therapy. The crude mortality rate with extended-hours hemodialysis was 6.4 deaths per 100 patient-years compared with 14.7 deaths per 100 patient-years for conventional hemodialysis. In the primary analysis, patients treated with extended-hours hemodialysis had a 33% lower adjusted risk of death compared to those who were treated with a conventional regimen (95% confidence interval: 7% to 51%). Additional analyses accounting for analytical assumptions regarding exposure and outcome, facility-level confounders, and prior modality history were similar. Thus, in this large nationally representative cohort, treatment with extended-hours hemodialysis was associated with a lower risk for mortality compared to treatment with conventional in-center therapy. Adequately powered randomized clinical trials comparing extended-hours to conventional hemodialysis are required to confirm these findings. PMID:27555118

  19. Holographic study of conventional and negative Poisson's ratio metallic foams - Elasticity, yield and micro-deformation

    NASA Technical Reports Server (NTRS)

    Chen, C. P.; Lakes, R. S.

    1991-01-01

    An experimental study by holographic interferometry is reported of the following material properties of conventional and negative Poisson's ratio copper foams: Young's moduli, Poisson's ratios, yield strengths and characteristic lengths associated with inhomogeneous deformation. The Young's modulus and yield strength of the conventional copper foam were comparable to those predicted by microstructural modeling on the basis of cellular rib bending. The reentrant copper foam exhibited a negative Poisson's ratio, as indicated by the elliptical contour fringes on the specimen surface in the bending tests. Inhomogeneous, non-affine deformation was observed holographically in both foam materials.

  20. Comparison of the lysis centrifugation method with the conventional blood culture method in cases of sepsis in a tertiary care hospital.

    PubMed

    Parikh, Harshal R; De, Anuradha S; Baveja, Sujata M

    2012-07-01

    Physicians and microbiologists have long recognized that the presence of living microorganisms in the blood of a patient carries with it considerable morbidity and mortality. Hence, blood cultures have become critically important and frequently performed test in clinical microbiology laboratories for diagnosis of sepsis. To compare the conventional blood culture method with the lysis centrifugation method in cases of sepsis. Two hundred nonduplicate blood cultures from cases of sepsis were analyzed using two blood culture methods concurrently for recovery of bacteria from patients diagnosed clinically with sepsis - the conventional blood culture method using trypticase soy broth and the lysis centrifugation method using saponin by centrifuging at 3000 g for 30 minutes. Overall bacteria recovered from 200 blood cultures were 17.5%. The conventional blood culture method had a higher yield of organisms, especially Gram positive cocci. The lysis centrifugation method was comparable with the former method with respect to Gram negative bacilli. The sensitivity of lysis centrifugation method in comparison to conventional blood culture method was 49.75% in this study, specificity was 98.21% and diagnostic accuracy was 89.5%. In almost every instance, the time required for detection of the growth was earlier by lysis centrifugation method, which was statistically significant. Contamination by lysis centrifugation was minimal, while that by conventional method was high. Time to growth by the lysis centrifugation method was highly significant (P value 0.000) as compared to time to growth by the conventional blood culture method. For the diagnosis of sepsis, combination of the lysis centrifugation method and the conventional blood culture method with trypticase soy broth or biphasic media is advocable, in order to achieve faster recovery and a better yield of microorganisms.

  1. Effect of mechanical alloying synthesis process on the dielectric properties of (Bi{sub 0.5}Na{sub 0.5}){sub 0.94}Ba{sub 0.06}TiO{sub 3} piezoceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghazanfari, Mohammad Reza, E-mail: Ghazanfari.mr@gmail.com; Amini, Rasool; Shams, Seyyedeh Fatemeh

    Highlights: • MA samples show higher dielectric permittivity and Curie temperature. • In MA samples, dielectric loss is almost 27% less than conventional ones. • In MA samples, sintering time and temperature are lower than conventional ones. • In MA samples, particle morphology is more homogeneous conventional ones. • In MA samples, crystallite size is smaller conventional ones. - Abstract: In present work, in order to study the effects of synthesis techniques on dielectric properties, the BNBT lead-free piezoceramics with (Bi{sub 0.5}Na{sub 0.5}){sub 0.94}Ba{sub 0.06}TiO{sub 3} stoichiometry (called as BNBT6) were synthesized by mechanical alloying (MA) and conventional mixed oxidesmore » methods. The structural, microstructural, and dielectric properties were carried out by X-ray diffractometer (XRD), scanning electron microscope (SEM), and impedance analyzer LCR meter, respectively. Based on results, the density of MA samples is considerably higher than conventional samples owning to smaller particles size and more uniformity of particle shape of MA samples. Moreover, the dielectric properties of MA samples are comparatively improved in which the dielectric loss of these samples is almost 27% less than conventional ones. Furthermore, MA samples exhibit obviously higher dielectric permittivity and Curie temperature compared to the conventional samples.« less

  2. Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia

    PubMed Central

    Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha-Diago, María; Peñarrocha, Miguel

    2012-01-01

    Objective: To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. Materials and methods: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for res-pective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Results: A total of 200 oral anesthetic procedures were carried out in 100 patients. The mean patient age was 28.6±9.92 years. Fifty-five vestibular infiltrations and 45 mandibular blocks were performed. All patients were also subjected to IA. The type of intervention (conservative or endodontic) exerted no significant influence (p=0.58 and p=0.62, respectively). The latency period was 8.52±2.44 minutes for the conventional techniques and 0.89±0.73 minutes for IA – the difference being statistically significant (p<0.05). Regarding patient anesthesia sensation, the infiltrative techniques lasted a maximum of one hour, the inferior alveolar nerve blocks lasted between 1-3 hours, and IA lasted only 2.5 minutes – the differences being statistically significant (p≤0.0000, Φ=0.29). Anesthetic success was recorded in 89% of the conventional procedures and in 78% of the IA. Most patients preferred IA (61%) (p=0.0032). Conclusions: The two anesthetic procedures have been compared for latency, duration of anesthetic effect, anesthetic success rate and patient preference. Intraosseous anesthesia has been shown to be a technique to be taken into account when planning conservative and endodontic treatments. Key words: Anesthesia, intraosseous, oral anesthesia, Stabident®, infiltrative, mandibular block. PMID:22143700

  3. Performance and cost analysis of Siriraj liquid-based cytology: a direct-to-vial study.

    PubMed

    Laiwejpithaya, Somsak; Benjapibal, Mongkol; Laiwejpithaya, Sujera; Wongtiraporn, Weerasak; Sangkarat, Suthi; Rattanachaiyanont, Manee

    2009-12-01

    To compare the cytological diagnoses, specimen adequacy, and cost of the Siriraj liquid-based cytology (LBC) with those of the conventional smear technique. An observational study with historical comparison was conducted in a tertiary university hospital. Cytological reports of 23,676 Siriraj-LBC specimens obtained in 2006 were compared with those of 25,510 conventional smears obtained in 2004. Overall prevalence of abnormal cervical cytology detected by conventional smear was 1.76% and by Siriraj-LBC was 3.70%. Compared with the conventional method, the Siriraj-LBC yielded a significantly higher overall detection rate of abnormal cervical cytology, with a 110.23% increase in the detection rate (P<0.001), mainly due to the increase in diagnosis of squamous intraepithelial lesions (SIL), both low and high grade, together with atypical squamous cells of undetermined significance, "atypical squamous cells cannot exclude HSIL", and malignancies, but not atypical glandular cells. The Siriraj-LBC had a smaller proportion of unsatisfactory slides (4.94% vs. 18.60%, P<0.001) and a higher negative predictive value (96.33% vs. 92.74%, P=0.001), but no difference in positive predictive value (83.03% vs. 86.83%, P=0.285). The cost of Siriraj-LBC was approximately 67% higher than that of the conventional cytology used in Siriraj Hospital and 50-70% lower than that of the commercially available LBC techniques in Thailand. The Siriraj-LBC increases the detection rate of abnormal cytology, improves specimen adequacy, and enhances the negative predictive value without compromising the positive predictive value. For centers where conventional Pap smear does not perform well, the introduction of a low cost Siriraj-LBC might help to improve performance and it may be an economical alternative to the commercially available liquid-based cytology.

  4. Meta-analysis of oral Chinese herbal medicine as an adjuvant treatment in relieving pain secondary to bone metastases.

    PubMed

    Wang, Shi-Jun; Xu, Juan; Gong, Dan-Dan; Man, Chang-Feng; Fan, Yu

    2013-10-14

    To assess the effectiveness of oral Chinese herbal medicine (CHM) in relieving pain secondary to bone metastases in patients. The searched electronic literature databases included both English and Chinese articles published in the MEDLINE, EMBASE, Wanfang database and China National Knowledge Infrastructure (up to December 2012). The studies included randomized controlled trials (RCTs) comparing CHM plus conventional treatment with conventional treatment alone for patients with pain secondary to bone metastases. The outcomes were the odds ratio (OR) with 95% confidence intervals (CI) for the pain-relief rate and adverse events. A total of 16 RCTs involving 1,008 patients were identified and analyzed. All of the included RCTs were associated with a moderate to high risk of bias. In the metaanalysis, CHM plus conventional treatment increased the pain-relief rate compared with the conventional treatment alone (OR, 2.59; 95% CI 1.95 to 3.45). In subgroup analysis, the pooled OR of the pain-relief rate of CHM plus conventional treatment compared with conventional treatment was 3.11 (95% CI 2.01 to 4.79) for CHM plus bisphosphonates, 2.24 (95% CI 1.33 to 3.78) for CHM plus analgesics, 2.28 (95% CI 1.09 to 4.79) for CHM plus radiotherapy, and 2.22 (95% CI 0.95 to 5.15) for CHM plus analgesics and bisphosphonates. The adverse events included nausea, vomiting, dizziness, fever, and constipation. No serious adverse events were reported in any of the included studies. CHM interventions appear to have beneficial effects on pain secondary to bone metastases in patients. However, published efficacy trials are small in size to draw any firm conclusions.

  5. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    PubMed

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (P<0.001 for circumference; P=0.003 for thinning). Severe collagen damage such as denatured collagen was also significantly less in the irrigated compared with the conventional radiofrequency group (P<0.001). Nerve damage although not statistically different between the irrigated radiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (P<0.001). Saline irrigation significantly reduces arterial and periarterial tissue damage during radiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  6. Clinicopathologic features and survival in Spitzoid malignant melanoma and conventional malignant melanoma.

    PubMed

    Semkova, Kristina; Lott, Jason P; Lazova, Rossitza

    2014-09-01

    Although recent advances in genetics have revealed distinct mutational profiles and molecular signaling pathways associated with Spitzoid malignant melanoma (SMM), less is known about the clinicopathologic characteristics and behavior of SMM compared with conventional melanoma. We sought to determine the clinicopathologic characteristics and mortality risk associated with SMM and conventional malignant melanoma. We conducted a retrospective study of 30 patients with SMM and 30 patients with conventional melanoma. The two groups were matched by age, gender, and depth of tumor invasion. Additional patient- and tumor-level characteristics were compared between groups and regression modeling was used to assess relative mortality risk. Unadjusted analyses of SMM and conventional malignant melanoma revealed no significant differences in clinical impression, anatomic location, mitotic rate, and presence of ulceration. Sentinel lymph node biopsy, completion lymphadenectomy, and visceral metastases did not differ between groups. Cox proportional hazards regression showed no differences in mortality between Spitzoid and conventional melanoma. Small sample size, short follow-up duration, and residual confounding may limit the accuracy and generalizability of our results. SMM and conventional malignant melanoma differ in some clinicopathologic features. We did not find a statistically significant difference in mortality between the two. Copyright © 2014 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  7. Improved alignment and operating room efficiency with patient-specific instrumentation for TKA.

    PubMed

    Renson, Luc; Poilvache, Pascal; Van den Wyngaert, Hans

    2014-12-01

    Achieving accurate alignment in total knee arthroplasty (TKA) remains a concern. Patient-specific instrumentation (PSI) produced using preoperative 3D models was developed to offer surgeons a simplified, reliable, efficient and customised TKA procedure. In this prospective study, 60 patients underwent TKA with conventional instrumentation and 71 patients were operated on using PSI. The primary endpoint was surgical time. Secondary endpoints included operating room (OR) time, the number of instrument trays used and postoperative radiographic limb alignment. Compared to conventional instrumentation, PSI significantly reduced total surgical time by 8.9 ± 3.3 min (p=0.038), OR time by 8.6 ± 4.2 min (p=0.043), and the number of instrument trays by six trays (p<0.001). Mechanical axis malalignment of the lower limb of >3° was observed in 13% of PSI patients versus 29% with conventional instrumentation (p=0.043). PSI predicted the size of the femoral and tibial components actually used in 85.9% and 78.9% of cases, respectively. PSI improves alignment, surgical and OR time, reduces the number of instruments trays used compared to conventional instrumentation in patients undergoing TKA and results in fewer outliers in overall mechanical alignment in the coronal plane. Prospective comparative therapeutic study. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. For 481 biomedical open access journals, articles are not searchable in the Directory of Open Access Journals nor in conventional biomedical databases

    PubMed Central

    Andresen, Kristoffer; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2015-01-01

    Background. Open access (OA) journals allows access to research papers free of charge to the reader. Traditionally, biomedical researchers use databases like MEDLINE and EMBASE to discover new advances. However, biomedical OA journals might not fulfill such databases’ criteria, hindering dissemination. The Directory of Open Access Journals (DOAJ) is a database exclusively listing OA journals. The aim of this study was to investigate DOAJ’s coverage of biomedical OA journals compared with the conventional biomedical databases. Methods. Information on all journals listed in four conventional biomedical databases (MEDLINE, PubMed Central, EMBASE and SCOPUS) and DOAJ were gathered. Journals were included if they were (1) actively publishing, (2) full OA, (3) prospectively indexed in one or more database, and (4) of biomedical subject. Impact factor and journal language were also collected. DOAJ was compared with conventional databases regarding the proportion of journals covered, along with their impact factor and publishing language. The proportion of journals with articles indexed by DOAJ was determined. Results. In total, 3,236 biomedical OA journals were included in the study. Of the included journals, 86.7% were listed in DOAJ. Combined, the conventional biomedical databases listed 75.0% of the journals; 18.7% in MEDLINE; 36.5% in PubMed Central; 51.5% in SCOPUS and 50.6% in EMBASE. Of the journals in DOAJ, 88.7% published in English and 20.6% had received impact factor for 2012 compared with 93.5% and 26.0%, respectively, for journals in the conventional biomedical databases. A subset of 51.1% and 48.5% of the journals in DOAJ had articles indexed from 2012 and 2013, respectively. Of journals exclusively listed in DOAJ, one journal had received an impact factor for 2012, and 59.6% of the journals had no content from 2013 indexed in DOAJ. Conclusions. DOAJ is the most complete registry of biomedical OA journals compared with five conventional biomedical databases. However, DOAJ only indexes articles for half of the biomedical journals listed, making it an incomplete source for biomedical research papers in general. PMID:26038727

  9. For 481 biomedical open access journals, articles are not searchable in the Directory of Open Access Journals nor in conventional biomedical databases.

    PubMed

    Liljekvist, Mads Svane; Andresen, Kristoffer; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2015-01-01

    Background. Open access (OA) journals allows access to research papers free of charge to the reader. Traditionally, biomedical researchers use databases like MEDLINE and EMBASE to discover new advances. However, biomedical OA journals might not fulfill such databases' criteria, hindering dissemination. The Directory of Open Access Journals (DOAJ) is a database exclusively listing OA journals. The aim of this study was to investigate DOAJ's coverage of biomedical OA journals compared with the conventional biomedical databases. Methods. Information on all journals listed in four conventional biomedical databases (MEDLINE, PubMed Central, EMBASE and SCOPUS) and DOAJ were gathered. Journals were included if they were (1) actively publishing, (2) full OA, (3) prospectively indexed in one or more database, and (4) of biomedical subject. Impact factor and journal language were also collected. DOAJ was compared with conventional databases regarding the proportion of journals covered, along with their impact factor and publishing language. The proportion of journals with articles indexed by DOAJ was determined. Results. In total, 3,236 biomedical OA journals were included in the study. Of the included journals, 86.7% were listed in DOAJ. Combined, the conventional biomedical databases listed 75.0% of the journals; 18.7% in MEDLINE; 36.5% in PubMed Central; 51.5% in SCOPUS and 50.6% in EMBASE. Of the journals in DOAJ, 88.7% published in English and 20.6% had received impact factor for 2012 compared with 93.5% and 26.0%, respectively, for journals in the conventional biomedical databases. A subset of 51.1% and 48.5% of the journals in DOAJ had articles indexed from 2012 and 2013, respectively. Of journals exclusively listed in DOAJ, one journal had received an impact factor for 2012, and 59.6% of the journals had no content from 2013 indexed in DOAJ. Conclusions. DOAJ is the most complete registry of biomedical OA journals compared with five conventional biomedical databases. However, DOAJ only indexes articles for half of the biomedical journals listed, making it an incomplete source for biomedical research papers in general.

  10. Comparison of autologous conditioned plasma injection, extracorporeal shockwave therapy, and conventional treatment for plantar fasciitis: a randomized trial.

    PubMed

    Chew, Kelvin Tai Loon; Leong, Darren; Lin, Cindy Y; Lim, Kay Kiat; Tan, Benedict

    2013-12-01

    To evaluate the efficacy of autologous conditioned plasma (ACP) compared with extracorporeal shockwave (ESWT) and conventional treatments for plantar fasciitis. Randomized trial. Sports medicine center in a tertiary care hospital. Fifty-four subjects (age range, 29-71 years) with unilateral chronic plantar fasciitis with more than 4 months of symptoms. Subjects randomized to 3 groups: 19 to ACP and conventional treatment (ACP group), 19 to ESWT and conventional treatment (ESWT group), and 16 to conventional treatment alone. Conventional treatment included stretching exercises and orthotics if indicated. Outcomes were pain-Visual Analog Scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasound plantar fascia thickness assessed at baseline before treatment and at 1 month, 3 months, and 6 months after treatment. VAS, AOFAS ankle-hindfoot scale, and plantar fascia thickness improved in all groups. Significant VAS pain score improvements in the ACP group compared with conventional treatment at month 1 (P = .037) and for the ESWT group compared with conventional treatment at months 1, 3, and 6 (P = .017, P = .022, and P = .042). The AOFAS ankle-hindfoot scale score improved in the ACP group at months 3 and 6 (P = .004 and P = .013) and, for the ESWT group, at months 1 and 3 (P = .011 and P = .003) compared with conventional treatment. Significant improvements in plantar fascia thickness were seen in the ACP group at months 1 and 3 compared with conventional treatments (P = .015 and P = .014) and at months 3 and 6 compared with the ESWT group (P = .019 and P = .027). No adverse events reported. Treatment of plantar fasciitis with ACP or ESWT plus conventional treatments resulted in improved pain and functional outcomes compared with conventional treatment alone. There was no significant difference between ACP and ESWT in terms of VAS and AOFAS ankle-hindfoot scale improvements, although the ACP group demonstrated greater reductions in plantar fascia thickness. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. Comparing the effectiveness of laser vs. conventional endoforehead lifting.

    PubMed

    Chang, Cheng-Jen; Yu, De-Yi; Chang, Shu-Ying; Hsiao, Yen-Chang

    2018-04-01

    The objective of this study was to compare the efficacy and safety of laser versus conventional endoforehead lifting. Over a period of 12 years (January 2000-January 2012), a total of 110 patients with hyperactive muscles over the frontal region have been collected for a retrospective study. The SurgiLase 150XJ CO 2 laser system, in conjunction with the flexible FIBERLASE, was used. The endoscope was 4 mm in diameter with an angle of 30°. The primary efficacy measurement was the assessment of the final outcome for using laser vs. conventional methods. Both groups were observed at three weeks, six weeks and six months after surgery. The most common complication in early convalescence (three weeks) was swelling. This was followed by local paraesthesia, ecchymosis, localized hematomas and scar with alopecia. All these problems disappeared completely after the 6-month study period. Based on a chi-square analysis, there were clinically and statistically significant differences favouring the laser endoforehead surgery in the operative time, early and late complications. All patients achieved significant improvement after both laser and conventional endoforehead surgery in the final outcome. However, the early and late complications indicated a greater difference in the laser group.

  12. Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review.

    PubMed

    Aragón, Mônica L C; Pontes, Luana F; Bichara, Lívia M; Flores-Mir, Carlos; Normando, David

    2016-08-01

    The development of 3D technology and the trend of increasing the use of intraoral scanners in dental office routine lead to the need for comparisons with conventional techniques. To determine if intra- and inter-arch measurements from digital dental models acquired by an intraoral scanner are as reliable and valid as the similar measurements achieved from dental models obtained through conventional intraoral impressions. An unrestricted electronic search of seven databases until February 2015. Studies that focused on the accuracy and reliability of images obtained from intraoral scanners compared to images obtained from conventional impressions. After study selection the QUADAS risk of bias assessment tool for diagnostic studies was used to assess the risk of bias (RoB) among the included studies. Four articles were included in the qualitative synthesis. The scanners evaluated were OrthoProof, Lava, iOC intraoral, Lava COS, iTero and D250. These studies evaluated the reliability of tooth widths, Bolton ratio measurements, and image superimposition. Two studies were classified as having low RoB; one had moderate RoB and the remaining one had high RoB. Only one study evaluated the time required to complete clinical procedures and patient's opinion about the procedure. Patients reported feeling more comfortable with the conventional dental impression method. Associated costs were not considered in any of the included study. Inter- and intra-arch measurements from digital models produced from intraoral scans appeared to be reliable and accurate in comparison to those from conventional impressions. This assessment only applies to the intraoral scanners models considered in the finally included studies. Digital models produced by intraoral scan eliminate the need of impressions materials; however, currently, longer time is needed to take the digital images. PROSPERO (CRD42014009702). None. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. Using methods from the data mining and machine learning literature for disease classification and prediction: A case study examining classification of heart failure sub-types

    PubMed Central

    Austin, Peter C.; Tu, Jack V.; Ho, Jennifer E.; Levy, Daniel; Lee, Douglas S.

    2014-01-01

    Objective Physicians classify patients into those with or without a specific disease. Furthermore, there is often interest in classifying patients according to disease etiology or subtype. Classification trees are frequently used to classify patients according to the presence or absence of a disease. However, classification trees can suffer from limited accuracy. In the data-mining and machine learning literature, alternate classification schemes have been developed. These include bootstrap aggregation (bagging), boosting, random forests, and support vector machines. Study design and Setting We compared the performance of these classification methods with those of conventional classification trees to classify patients with heart failure according to the following sub-types: heart failure with preserved ejection fraction (HFPEF) vs. heart failure with reduced ejection fraction (HFREF). We also compared the ability of these methods to predict the probability of the presence of HFPEF with that of conventional logistic regression. Results We found that modern, flexible tree-based methods from the data mining literature offer substantial improvement in prediction and classification of heart failure sub-type compared to conventional classification and regression trees. However, conventional logistic regression had superior performance for predicting the probability of the presence of HFPEF compared to the methods proposed in the data mining literature. Conclusion The use of tree-based methods offers superior performance over conventional classification and regression trees for predicting and classifying heart failure subtypes in a population-based sample of patients from Ontario. However, these methods do not offer substantial improvements over logistic regression for predicting the presence of HFPEF. PMID:23384592

  14. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    PubMed

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  15. FT-Raman study of dehydrogenation polymer (DHP) lignins

    Treesearch

    Umesh P. Agarwal; Noritsugu Terashima

    2003-01-01

    Compared to conventional Raman spectroscopy where samples are excited using visible light lasers, 1064 nm-excited FT-Raman technique has the single most important advantage that the sample-fluorescence is significantly suppressed for samples that are strongly fluorescent. DHPs are difficult to analyze in conventional Raman because small amounts of chromophores present...

  16. The Effectiveness of PowerPoint Presentation and Conventional Lecture on Pedagogical Content Knowledge Attainment

    ERIC Educational Resources Information Center

    Cosgun Ögeyik, Muhlise

    2017-01-01

    In English language teaching settings, the type of lecture is important since students should be exposed to instantly recognisable linguistic features in the target language through interaction. This quasi-experimental study was designed to compare the effectiveness of PowerPoint presentations (PPP) and conventional lecture/discussion sessions on…

  17. Metaphor Comprehension by Deaf Young Adults

    ERIC Educational Resources Information Center

    Gold, Rinat; Segal, Osnat

    2017-01-01

    In the present study, we compared the processing of both conventional and novel metaphors by deaf versus hearing young adults. Eighteen deaf participants with severe-to-profound hearing loss and 18 controls matched for age, sex, and years of education were presented with word pairs of 4 types (literal, conventional metaphors, novel metaphors, and…

  18. Comparative Analysis Between Guided Self-Instruction and Conventional Lectures in Neuroanatomy

    ERIC Educational Resources Information Center

    de Carvalho, Claudio A. F.; And Others

    1977-01-01

    A study using 60 first-year medical students in the Santo Amaro Faculty of Medicine, San Paulo, Brazil, found that self-instructional methods such as guided self-instruction or discussion groups are not superior to conventional classes. Self-instruction does have the advantages of low cost and easy applicability. (LBH)

  19. Comparative evaluation of surgical outcome after removal of impacted mandibular third molars using a Piezotome or a conventional handpiece: a prospective study.

    PubMed

    Goyal, Manoj; Marya, Karan; Jhamb, Aakarsh; Chawla, Sonia; Sonoo, Priyanshu Ranjan; Singh, Veenita; Aggarwal, Anuj

    2012-09-01

    Our aim was to compare the use of a conventional rotary handpiece and a Piezosurgical unit for extraction of lower third molars. We studied 40 patients, who were allocated alternately to have the third molar removed with either the handpiece or the Piezosurgical unit. Pain, trismus, and oedema were evaluated at baseline and then postoperatively, together with paraesthesiae, on postoperative days 1, 3, 5, 7, and 15. Damage to surrounding tissue was checked on the same day whereas dry socket was evaluated from postoperative day 3 onwards. More patients complained of pain in the conventional group, they also required more analgesics, and they developed trismus more often than in the Piezosurgery group. There was also significantly more postoperative swelling in the conventional group. Patients were also evaluated using the subjective Postoperative Symptom Severity (PoSSe) scale. Our results suggest that apart from some inherent limitations with the Piezotome, it is a valuable alternative for extraction of third molars. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. The Effect of Adaptive Nonlinear Frequency Compression on Phoneme Perception.

    PubMed

    Glista, Danielle; Hawkins, Marianne; Bohnert, Andrea; Rehmann, Julia; Wolfe, Jace; Scollie, Susan

    2017-12-12

    This study implemented a fitting method, developed for use with frequency lowering hearing aids, across multiple testing sites, participants, and hearing aid conditions to evaluate speech perception with a novel type of frequency lowering. A total of 8 participants, including children and young adults, participated in real-world hearing aid trials. A blinded crossover design, including posttrial withdrawal testing, was used to assess aided phoneme perception. The hearing aid conditions included adaptive nonlinear frequency compression (NFC), static NFC, and conventional processing. Enabling either adaptive NFC or static NFC improved group-level detection and recognition results for some high-frequency phonemes, when compared with conventional processing. Mean results for the distinction component of the Phoneme Perception Test (Schmitt, Winkler, Boretzki, & Holube, 2016) were similar to those obtained with conventional processing. Findings suggest that both types of NFC tested in this study provided a similar amount of speech perception benefit, when compared with group-level performance with conventional hearing aid technology. Individual-level results are presented with discussion around patterns of results that differ from the group average.

  1. Comparative life cycle studies on poly(3-hydroxybutyrate)-based composites as potential replacement for conventional petrochemical plastics.

    PubMed

    Pietrini, Matteo; Roes, Lex; Patel, Martin K; Chiellini, Emo

    2007-07-01

    A cradle-to-grave environmental life cycle assessment (LCA) of a few poly(3-hydroxybutyrate) (PHB) based composites has been performed and was compared to commodity petrochemical polymers. The end products studied are a cathode ray tube (CRT) monitor housing (conventionally produced from high-impact polystyrene, HIPS) and the internal panels of an average car (conventionally produced from glass-fibers-filled polypropylene, PP-GF). The environmental impact is evaluated on the basis of nonrenewable energy use (NREU) and global warming potential over a 100 years time horizon (GWP100). Sugar cane bagasse (SCB) and nanoscaled organophilic montmorillonite (OMMT) are used as PHB fillers. The results obtained show that, despite the unsatisfying mechanical properties of PHB composites, depending on the type of filler and on the product, it is possible to reach lower environmental impacts than by use of conventional petrochemical polymers. These savings are mainly related to the PHB production process, while there are no improvements related to composites preparation. SCB-based composites seem to be environmentally superior to clay-based ones.

  2. Time-Efficiency Analysis Comparing Digital and Conventional Workflows for Implant Crowns: A Prospective Clinical Crossover Trial.

    PubMed

    Joda, Tim; Brägger, Urs

    2015-01-01

    To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

  3. Measles vaccination coverage estimates from surveys, clinic records, and immune markers in oral fluid and blood: a population-based cross-sectional study.

    PubMed

    Hayford, Kyla T; Shomik, Mohammed S; Al-Emran, Hassan M; Moss, William J; Bishai, David; Levine, Orin S

    2013-12-20

    Recent outbreaks of measles and polio in low-income countries illustrate that conventional methods for estimating vaccination coverage do not adequately identify susceptible children. Immune markers of protection against vaccine-preventable diseases in oral fluid (OF) or blood may generate more accurate measures of effective vaccination history, but questions remain about whether antibody surveys are feasible and informative tools for monitoring immunization program performance compared to conventional vaccination coverage indicators. This study compares six indicators of measles vaccination status, including immune markers in oral fluid and blood, from children in rural Bangladesh and evaluates the implications of using each indicator to estimate measles vaccination coverage. A cross-sectional population-based study of children ages 12-16 months in Mirzapur, Bangladesh, ascertained measles vaccination (MCV1) history from conventional indicators: maternal report, vaccination card records, 'card+history' and EPI clinic records. Oral fluid from all participants (n=1226) and blood from a subset (n=342) were tested for measles IgG antibodies as indicators of MCV1 history and compared to conventional MCV1 coverage indicators. Maternal report yielded the highest MCV1 coverage estimates (90.8%), followed by EPI records (88.6%), and card+history (84.2%). Seroprotection against measles by OF (57.3%) was significantly lower than other indicators, even after adjusting for incomplete seroconversion and assay performance (71.5%). Among children with blood results, 88.6% were seroprotected, which was significantly higher than coverage by card+history and OF serostatus but consistent with coverage by maternal report and EPI records. Children with vaccination cards or EPI records were more likely to have a history of receiving MCV1 than those without cards or records. Despite similar MCV1 coverage estimates across most indicators, within-child agreement was poor for all indicators. Measles IgG antibodies in OF was not a suitable immune marker for monitoring measles vaccination coverage in this setting. Because agreement between conventional MCV1 indicators was mediocre, immune marker surveillance with blood samples could be used to validate conventional MCV1 indicators and generate adjusted results that can be compared across indicators.

  4. User-composable Electronic Health Record Improves Efficiency of Clinician Data Viewing for Patient Case Appraisal: A Mixed-Methods Study.

    PubMed

    Senathirajah, Yalini; Kaufman, David; Bakken, Suzanne

    2016-01-01

    Challenges in the design of electronic health records (EHRs) include designing usable systems that must meet the complex, rapidly changing, and high-stakes information needs of clinicians. The ability to move and assemble elements together on the same page has significant human-computer interaction (HCI) and efficiency advantages, and can mitigate the problems of negotiating multiple fixed screens and the associated cognitive burdens. We compare MedWISE-a novel EHR that supports user-composable displays-with a conventional EHR in terms of the number of repeat views of data elements for patient case appraisal. The study used mixed-methods for examination of clinical data viewing in four patient cases. The study compared use of an experimental user-composable EHR with use of a conventional EHR, for case appraisal. Eleven clinicians used a user-composable EHR in a case appraisal task in the laboratory setting. This was compared with log file analysis of the same patient cases in the conventional EHR. We investigated the number of repeat views of the same clinical information during a session and across these two contexts, and compared them using Fisher's exact test. There was a significant difference (p<.0001) in proportion of cases with repeat data element viewing between the user-composable EHR (14.6 percent) and conventional EHR (72.6 percent). Users of conventional EHRs repeatedly viewed the same information elements in the same session, as revealed by log files. Our findings are consistent with the hypothesis that conventional systems require that the user view many screens and remember information between screens, causing the user to forget information and to have to access the information a second time. Other mechanisms (such as reduction in navigation over a population of users due to interface sharing, and information selection) may also contribute to increased efficiency in the experimental system. Systems that allow a composable approach that enables the user to gather together on the same screen any desired information elements may confer cognitive support benefits that can increase productive use of systems by reducing fragmented information. By reducing cognitive overload, it can also enhance the user experience.

  5. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial

    PubMed Central

    Zhang, Dong; Yin, Dong; Song, Chenxi; Zhu, Chengang; Kirtane, Ajay J; Xu, Bo; Dou, Kefei

    2017-01-01

    Introduction The intentional strategy (aggressive side branch (SB) protection strategy: elective two-stent strategy or jailed balloon technique) is thought to be associated with lower SB occlusion rate than conventional strategy (provisional two-stent strategy or jailed wire technique). However, most previous studies showed comparable outcomes between the two strategies, probably due to no risk classification of SB occlusion when enrolling patients. There is still no randomised trial compared the intentional and conventional strategy when treating bifurcation lesions with high risk of SB occlusion. We aim to investigate if intentional strategy is associated with significant reduction of SB occlusion rate compared with conventional strategy in high-risk patients. Methods and analysis The Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion (CIT-RESOLVE) is a prospective, randomised, single-blind, multicentre clinical trial comparing the rate of SB occlusion between the intentional strategy group and the conventional strategy group (positive control group) in a consecutive cohort of patients with high risk of side branch occlusion defined by V-RESOLVE score, which is a validated angiographic scoring system to evaluate the risk of SB occlusion in bifurcation intervention and used as one of the inclusion criteria to select patients with high SB occlusion risk (V-RESOLVE score ≥12). A total of 21 hospitals from 10 provinces in China participated in the present study. 566 patients meeting all inclusion/exclusion criteria are randomised to either intentional strategy group or conventional strategy group. The primary endpoint is SB occlusion (defined as any decrease in thrombolysis in myocardial infarction flow grade or absence of flow in SB after main vessel stenting). All patients are followed up for 12-month postdischarge. Ethics and dissemination The protocol has been approved by all local ethics committee. The ethics committee have approved the study protocol, evaluated the risk to benefit ratio, allowed operators with a minimum annual volume of 200 cases to participate in the percutaneous coronary intervention procedure and permitted them to perform both conventional and intentional strategies. Written informed consent would be acquired from all participants. The findings of the trial will be shared by the participant hospitals and disseminated through peer-reviewed journals. Trial registration number NCT02644434; Pre-results. PMID:28606906

  6. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial.

    PubMed

    Zhang, Dong; Yin, Dong; Song, Chenxi; Zhu, Chengang; Kirtane, Ajay J; Xu, Bo; Dou, Kefei

    2017-06-12

    The intentional strategy (aggressive side branch (SB) protection strategy: elective two-stent strategy or jailed balloon technique) is thought to be associated with lower SB occlusion rate than conventional strategy (provisional two-stent strategy or jailed wire technique). However, most previous studies showed comparable outcomes between the two strategies, probably due to no risk classification of SB occlusion when enrolling patients. There is still no randomised trial compared the intentional and conventional strategy when treating bifurcation lesions with high risk of SB occlusion. We aim to investigate if intentional strategy is associated with significant reduction of SB occlusion rate compared with conventional strategy in high-risk patients. The Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion (CIT-RESOLVE) is a prospective, randomised, single-blind, multicentre clinical trial comparing the rate of SB occlusion between the intentional strategy group and the conventional strategy group (positive control group) in a consecutive cohort of patients with high risk of side branch occlusion defined by V-RESOLVE score, which is a validated angiographic scoring system to evaluate the risk of SB occlusion in bifurcation intervention and used as one of the inclusion criteria to select patients with high SB occlusion risk (V-RESOLVE score ≥12). A total of 21 hospitals from 10 provinces in China participated in the present study. 566 patients meeting all inclusion/exclusion criteria are randomised to either intentional strategy group or conventional strategy group. The primary endpoint is SB occlusion (defined as any decrease in thrombolysis in myocardial infarction flow grade or absence of flow in SB after main vessel stenting). All patients are followed up for 12-month postdischarge. The protocol has been approved by all local ethics committee. The ethics committee have approved the study protocol, evaluated the risk to benefit ratio, allowed operators with a minimum annual volume of 200 cases to participate in the percutaneous coronary intervention procedure and permitted them to perform both conventional and intentional strategies. Written informed consent would be acquired from all participants. The findings of the trial will be shared by the participant hospitals and disseminated through peer-reviewed journals. NCT02644434; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Indirect comparisons of efficacy and weekly factor consumption during continuous prophylaxis with recombinant factor VIII Fc fusion protein and conventional recombinant factor VIII products.

    PubMed

    Iorio, A; Krishnan, S; Myrén, K J; Lethagen, S; McCormick, N; Yermakov, S; Karner, P

    2017-05-01

    Recombinant factor VIII (rFVIII) products with extended half-lives have the potential to improve adherence and outcomes in haemophilia beyond the results obtained with conventional rFVIII products. In the absence of head-to-head comparisons, annualized bleed rates (ABRs) and weekly factor consumption with rFVIII Fc fusion protein (rFVIIIFc) and conventional rFVIII products were indirectly compared using studies of continuous prophylaxis. A systematic literature review was conducted to identify studies of rFVIII products for comparison with rFVIIIFc in the continuous prophylactic treatment of previously treated adolescents and adults with moderate and severe haemophilia A. Mean ABRs were compared between rFVIIIFc and individual rFVIII studies and between rFVIIIFc and a pooled measure for rFVIII estimated by meta-analysis. Comparisons of factor consumption were based on mean or median weekly factor consumption. Results from seven studies of conventional rFVIII products (injections 2-4 times week -1 ) were compared with rFVIIIFc (injections 1.4-2.4 times week -1 ). The pooled mean ABR for rFVIII products was significantly higher compared with rFVIIIFc (difference = 2.0; P = 0.007). Compared with most rFVIII studies, the reported weekly factor consumption was lower with rFVIIIFc [mean differences = 15.5-21.8 IU kg -1 week -1 (17-26%); median differences = 12.7-29.8 IU kg -1 week -1 (16-37%)]. In one comparison, mean weekly factor consumption with rFVIII was significantly lower but mean ABR was significantly higher than rFVIIIFc. Prophylaxis with rFVIIIFc may be associated with improved bleeding rates and lower weekly factor consumption than more frequently injected rFVIII products. Relative to rFVIII products with similar bleeding rates, results indicate that rFVIIIFc is associated with reduced weekly factor consumption while requiring fewer prescribed injections. © 2017 John Wiley & Sons Ltd.

  8. The validation study on a three-dimensional burn estimation smart-phone application: accurate, free and fast?

    PubMed

    Cheah, A K W; Kangkorn, T; Tan, E H; Loo, M L; Chong, S J

    2018-01-01

    Accurate total body surface area burned (TBSAB) estimation is a crucial aspect of early burn management. It helps guide resuscitation and is essential in the calculation of fluid requirements. Conventional methods of estimation can often lead to large discrepancies in burn percentage estimation. We aim to compare a new method of TBSAB estimation using a three-dimensional smart-phone application named 3D Burn Resuscitation (3D Burn) against conventional methods of estimation-Rule of Palm, Rule of Nines and the Lund and Browder chart. Three volunteer subjects were moulaged with simulated burn injuries of 25%, 30% and 35% total body surface area (TBSA), respectively. Various healthcare workers were invited to use both the 3D Burn application as well as the conventional methods stated above to estimate the volunteer subjects' burn percentages. Collective relative estimations across the groups showed that when used, the Rule of Palm, Rule of Nines and the Lund and Browder chart all over-estimated burns area by an average of 10.6%, 19.7%, and 8.3% TBSA, respectively, while the 3D Burn application under-estimated burns by an average of 1.9%. There was a statistically significant difference between the 3D Burn application estimations versus all three other modalities ( p  < 0.05). Time of using the application was found to be significantly longer than traditional methods of estimation. The 3D Burn application, although slower, allowed more accurate TBSAB measurements when compared to conventional methods. The validation study has shown that the 3D Burn application is useful in improving the accuracy of TBSAB measurement. Further studies are warranted, and there are plans to repeat the above study in a different centre overseas as part of a multi-centre study, with a view of progressing to a prospective study that compares the accuracy of the 3D Burn application against conventional methods on actual burn patients.

  9. The Effect of Right Colon Retroflexion on Adenoma Detection: A Systematic Review and Meta-analysis.

    PubMed

    Cohen, Jonah; Grunwald, Douglas; Grossberg, Laurie B; Sawhney, Mandeep S

    2017-10-01

    Although colonoscopy with polypectomy can prevent up to 80% of colorectal cancers, a significant adenoma miss rate still exists, particularly in the right colon. Previous studies addressing right colon retroflexion have revealed discordant evidence regarding the benefit of this maneuver on adenoma detection with concomitant concerns about safety and rates of maneuver success. In this meta-analysis, we sought to determine the effect of right colon retroflexion on improving adenoma detection compared with conventional colonoscopy without retroflexion, as well as determine the rates of retroflexion maneuver success and adverse events. Multiple databases including MEDLINE, Embase, and Web of Science were searched for studies on right colon retroflexion and its impact on adenoma detection compared with conventional colonoscopy. Pooled analyses of adenoma detection and retroflexion success were based on mixed-effects and random-effects models with heterogeneity analyses. Eight studies met the inclusion criteria (N=3660). The primary analysis comparing colonoscopy with right-sided retroflexion versus conventional colonoscopy to determine the per-adenoma miss rate in the right colon was 16.9% (95% confidence interval, 12.5%-22.5%). The overall rate of successful retroflexion was 91.9% (95% confidence interval, 86%-95%) and rate of adverse events was 0.03%. Colonoscopy with right-sided retroflexion significantly increases the detection of adenomas in the right colon compared with conventional colonoscopy with a high rate of maneuver success and small risk of adverse events. Thus, reexamination of the right colon in retroflexed view should be strongly considered in future standard of care colonoscopy guidelines for quality improvement in colon cancer prevention.

  10. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    PubMed

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  11. Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography.

    PubMed

    Fink, Christian; Hallscheidt, Peter J; Noeldge, Gerd; Kampschulte, Annette; Radeleff, Boris; Hosch, Waldemar P; Kauffmann, Günter W; Hansmann, Jochen

    2002-02-01

    The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.

  12. Microwave processing of gustatory tissues for immunohistochemistry

    PubMed Central

    Bond, Amanda; Kinnamon, John C.

    2013-01-01

    We use immunohistochemistry to study taste cell structure and function as a means to elucidate how taste receptor cells communicate with nerve fibers and adjacent taste cells. This conventional method, however, is time consuming. In the present study we used taste buds from rat circumvallate papillae to compare conventional immunohistochemical tissue processing with microwave processing for the colocalization of several biochemical pathway markers (PLCβ2, syntaxin-1, IP3R3, α-gustducin) and the nuclear stain, Sytox. The results of our study indicate that in microwave versus conventional immunocytochemistry: (1) fixation quality is improved; (2) the amount of time necessary for processing tissue is decreased; (3) antigen retrieval is no longer needed; (4) image quality is superior. In sum, microwave tissue processing of gustatory tissues is faster and superior to conventional immunohistochemical tissue processing for many applications. PMID:23473796

  13. Conventional and accelerated-solvent extractions of green tea (camellia sinensis) for metabolomics-based chemometrics.

    PubMed

    Kellogg, Joshua J; Wallace, Emily D; Graf, Tyler N; Oberlies, Nicholas H; Cech, Nadja B

    2017-10-25

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. Copyright © 2017. Published by Elsevier B.V.

  14. A Radiographic Comparison of Progressive and Conventional Loading on Crestal Bone Loss and Density in Single Dental Implants: A Randomized Controlled Trial Study

    PubMed Central

    Ghoveizi, Rahab; Alikhasi, Marzieh; Siadat, Mohammad-Reza; Siadat, Hakimeh; Sorouri, Majid

    2013-01-01

    Objective: Crestal bone loss is a biological complication in implant dentistry. The aim of this study was to compare the effect of progressive and conventional loading on crestal bone height and bone density around single osseointegrated implants in the posterior maxilla by a longitudinal radiographic assessment technique. Materials and Methods: Twenty micro thread implants were placed in 10 patients (two implants per patient). One of the two implants in each patient was assigned to progressive and the other to conventional loading groups. Eight weeks after surgery, conventional implants were restored with a metal ceramic crown and the progressive group underwent a progressive loading protocol. The progressive loading group took different temporary acrylic crowns at 2, 4 and 6 months. After eight months, acrylic crowns were replaced with a metal ceramic crown. Computer radiography of both progressive and conventional implants was taken at 2, 4, 6, and 12 months. Image analysis was performed to measure the height of crestal bone loss and bone density. Results: The mean values of crestal bone loss at month 12 were 0.11 (0.19) mm for progressively and 0.36 (0.36) mm for conventionally loaded implants, with a statistically significant difference (P < 0.05) using Wilcoxon sign rank. Progressively loaded group showed a trend for higher bone density gain compared to the conventionally loaded group, but when tested with repeated measure ANOVA, the differences were not statistically significant (P > 0.05). Conclusion: The progressive group showed less crestal bone loss in single osseointegrated implant than the conventional group. Bone density around progressively loaded implants showed increase in crestal, middle and apical areas. PMID:23724215

  15. Large spot transpupillary thermotherapy: a quicker laser for treatment of high risk prethreshold retinopathy of prematurity - a randomized study.

    PubMed

    Shah, Parag K; Narendran, V; Kalpana, N

    2011-01-01

    To compare structural and functional outcome and time efficiency between standard spot sized conventional pulsed mode diode laser and continuous mode large spot transpupillary thermotherapy (LS TTT) for treatment of high risk prethreshold retinopathy of prematurity (ROP). Ten eyes of five preterm babies having bilateral symmetrical high risk prethreshold ROP were included in this study. One eye of each baby was randomized to get either standard spot sized conventional pulsed mode diode laser or continuous mode LS TTT. There was no significant difference between structural or functional outcome in either group. The mean time taken for conventional diode laser was 20.07 minutes, while that for LS TTT was 12.3 minutes. LS TTT was 40% more time efficient than the conventional laser. It may be better suited for the very small fragile premature infants as it is quicker than the conventional laser.

  16. Chinese Herbal Medicine for Symptom Management in Cancer Palliative Care

    PubMed Central

    Chung, Vincent C.H.; Wu, Xinyin; Lu, Ping; Hui, Edwin P.; Zhang, Yan; Zhang, Anthony L.; Lau, Alexander Y.L.; Zhao, Junkai; Fan, Min; Ziea, Eric T.C.; Ng, Bacon F.L.; Wong, Samuel Y.S.; Wu, Justin C.Y.

    2016-01-01

    Abstract Use of Chinese herbal medicines (CHM) in symptom management for cancer palliative care is very common in Chinese populations but clinical evidence on their effectiveness is yet to be synthesized. To conduct a systematic review with meta-analysis to summarize results from CHM randomized controlled trials (RCTs) focusing on symptoms that are undertreated in conventional cancer palliative care. Five international and 3 Chinese databases were searched. RCTs evaluating CHM, either in combination with conventional treatments or used alone, in managing cancer-related symptoms were considered eligible. Effectiveness was quantified by using weighted mean difference (WMD) using random effect model meta-analysis. Fourteen RCTs were included. Compared with conventional intervention alone, meta-analysis showed that combined CHM and conventional treatment significantly reduced pain (3 studies, pooled WMD: −0.90, 95% CI: −1.69 to −0.11). Six trials comparing CHM with conventional medications demonstrated similar effect in reducing constipation. One RCT showed significant positive effect of CHM plus chemotherapy for managing fatigue, but not in the remaining 3 RCTs. The additional use of CHM to chemotherapy does not improve anorexia when compared to chemotherapy alone, but the result was concluded from 2 small trials only. Adverse events were infrequent and mild. CHM may be considered as an add-on to conventional care in the management of pain in cancer patients. CHM could also be considered as an alternative to conventional care for reducing constipation. Evidence on the use of CHM for treating anorexia and fatigue in cancer patients is uncertain, warranting further research. PMID:26886628

  17. Are nuclear ships environmentally safer than conventionally powered ships

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bone, C.A.; Molgaard, C.A.; Helmkamp, J.C.

    1988-03-01

    An epidemiologic analysis was conducted to determine if risk of hospitalization varied by age, ship type, or occupation between nuclear and conventional powered ship crews in the U.S. Navy. Study cohorts consisted of all male enlisted personnel who served exclusively aboard conventional or nuclear powered aircraft carriers and cruisers during the years 1975-1979; cases were those men hospitalized during this period (N = 48,242). Conventional ship personnel showed significantly elevated rates of injury and disease when compared to nuclear ship personnel. The largest relative risks by age occurred for conventional ship crewmen less than 30 years old. Seaman, logistics (supply),more » and healthcare personnel serving aboard conventional ships comprised the occupational groups exhibiting the highest hospitalization rate differentials. The results strongly suggest that nuclear ships provide a healthier, safer working and living environment than conventional ships.« less

  18. Comparison between mechanical freezer and conventional freezing using liquid nitrogen in normozoospermia.

    PubMed

    Rahana, A R; Ng, S P; Leong, C F; Rahimah, M D

    2011-10-01

    This study evaluated the effect of human semen cryopreservation using an ultra-low temperature technique with a mechanical freezer at -85°C as an alternative method to the conventional liquid nitrogen technique at -196°C. This was a prospective experimental study conducted in the Medically Assisted Conception unit, Department of Obstetrics and Gynaecology, National University Hospital, Malaysia from January 1, 2006 to April 30, 2007. All normozoospermic semen samples were included in the study. The concentration, motility and percentage of intact DNA of each semen sample were assessed before and after freezing and thawing on Days 7 and 30 post freezing. Sperm cryopreservation at -85°C was comparable to the conventional liquid nitrogen technique for a period of up to 30 days in a normozoospermic sample. There was no statistical difference in concentration (Day 7 p-value is 0.1, Day 30 p-value is 0.2), motility (Day 7 p-value is 0.9, Day 30 p-value is 0.5) and proportion of intact DNA (Day 7 p-value is 0.1, Day 30 p-value is 0.2) between the ultra-low temperature technique and conventional liquid nitrogen cryopreservation at Days 7 and 30 post thawing. This study clearly demonstrates that short-term storage of sperm at -85°C could be a viable alternative to conventional liquid nitrogen cryopreservation at -196°C due to their comparable post-thaw results.

  19. A Systematic Review of Economic Evaluations of Pacemaker Telemonitoring Systems.

    PubMed

    López-Villegas, Antonio; Catalán-Matamoros, Daniel; Martín-Saborido, Carlos; Villegas-Tripiana, Irene; Robles-Musso, Emilio

    2016-02-01

    Over the last decade, telemedicine applied to pacemaker monitoring has undergone extraordinary growth. It is not known if telemonitoring is more or less efficient than conventional monitoring. The aim of this study was to carry out a systematic review analyzing the available evidence on resource use and health outcomes in both follow-up modalities. We searched 11 databases and included studies published up until November 2014. The inclusion criteria were: a) experimental or observational design; b) studies based on complete economic evaluations; c) patients with pacemakers, and d) telemonitoring compared with conventional hospital monitoring. Seven studies met the inclusion criteria, providing information on 2852 patients, with a mean age of 81 years. The main indication for device implantation was atrioventricular block. With telemonitoring, cardiovascular events were detected and treated 2 months earlier than with conventional monitoring, thus reducing length of hospital stay by 34% and reducing routine and emergency hospital visits as well. There were no significant intergroup differences in perceived quality of life or number of adverse events. The cost of telemonitoring was 60% lower than that of conventional hospital monitoring. Compared with conventional monitoring, cardiovascular events were detected earlier and the number or hospitalizations and hospital visits was reduced with pacemaker telemonitoring. In addition, the costs associated with follow-up were lower with telemonitoring. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Estimating the cost-effectiveness of stroke units in France compared with conventional care.

    PubMed

    Launois, R; Giroud, M; Mégnigbêto, A C; Le Lay, K; Présenté, G; Mahagne, M H; Durand, I; Gaudin, A F

    2004-03-01

    The incidence of stroke in France is estimated at between 120 000 and 150 000 cases per year. This modeling study assessed the clinical and economic benefits of establishing specialized stroke units compared with conventional care. Data from the Dijon stroke registry were used to determine healthcare trajectories according to the degree of autonomy and organization of patient care. The relative risks of death or institutionalization or death or dependence after passage through a stroke unit were compared with conventional care. These risks were then inserted with the costing data into a Markov model to estimate the cost-effectiveness of stroke units. Patients cared for in a stroke unit survive more trimesters without sequelae in the 5 years after hospitalization than those cared for conventionally (11.6 versus 8.28 trimesters). The mean cost per patient at 5 years was estimated at 30 983 for conventional care and 34 638 in a stroke unit. An incremental cost-effectiveness ratio for stroke units of 1359 per year of life gained without disability was estimated. The cost-effectiveness ratio for stroke units is much lower than the threshold (53 400 ) of acceptability recognized by the international scientific community. This finding justifies organizational changes in the management of stroke patients and the establishment of stroke units in France.

  1. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    PubMed

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  2. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting.

    PubMed

    Suero, Eduardo M; Lueke, Ulrich; Stuebig, Timo; Hawi, Nael; Krettek, Christian; Liodakis, Emmanouil

    2018-04-25

    Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting. PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA. This is a retrospective cohort study of 385 primary TKAs (Women=59%. Mean age=67years. Mean BMI=30.1kg/m 2 ), which were performed using conventional instrumentation (n=117; 30%), computer navigation (n=209; 54%), or patient-specific instrumentation (n=59; 15%) in a low-volume center (<50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3° from neutral), average alignment and operation time were assessed. The risk of postoperative mechanical alignment outliers (>3°) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR=0.11; p<0.0001). No significant improvement was observed in the PSI group (27%) (RR=0.91; p=0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR=0.37; p=0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR=1.08; p=0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR=0.33; p=0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR=1.94; p=0.110). Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data. Retrospective cohort study. Level IV. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  3. A pilot comparative study of topical latanoprost and tacrolimus in combination with narrow-band ultraviolet B phototherapy and microneedling for the treatment of nonsegmental vitiligo.

    PubMed

    Korobko, Igor V; Lomonosov, Konstantin M

    2016-11-01

    Prostaglandins and their analogues are beneficial as topical agents in vitiligo treatment, yet neither of the previous study addressed their comparative efficiency with conventional topical agents used in vitiligo treatment. In this pilot (24 patients) left-right comparative study we addressed efficiency of prostaglandin F2α analogue latanoprost versus tacrolimus when combined with narrow-band ultraviolet B and microneedling in repigmentation of nonsegmental vitiligo lesions. Our results confirm potency of prostaglandins, in particular, that of latanoprost, in inducing repigmentation, with the efficiency being at least comparable to that of tacrolimus, while contribution of microneedling remains unclear. In summary, results of our study provide further evidences for justified use of prostaglandins, in particular, latanoprost, in vitiligo treatment. In turn, this warrants future studies on the topic aiming to conclusively introduce prostaglandin-based formulations as conventional agents for vitiligo management. © 2016 Wiley Periodicals, Inc.

  4. Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients.

    PubMed

    Yoneyama, Hiroto; Shibutani, Takayuki; Konishi, Takahiro; Mizutani, Asuka; Hashimoto, Ryosuke; Onoguchi, Masahisa; Okuda, Koichi; Matsuo, Shinro; Nakajima, Kenichi; Kinuya, Seigo

    2017-09-01

    The IQ•SPECT system, which is equipped with multifocal collimators ( SMART ZOOM) and uses ordered-subset conjugate gradient minimization as the reconstruction algorithm, reduces the acquisition time of myocardial perfusion imaging compared with conventional SPECT systems equipped with low-energy high-resolution collimators. We compared the IQ•SPECT system with a conventional SPECT system for estimating left ventricular ejection fraction (LVEF) in patients with a small heart (end-systolic volume < 20 mL). Methods: The study consisted of 98 consecutive patients who underwent a 1-d stress-rest myocardial perfusion imaging study with a 99m Tc-labeled agent for preoperative risk assessment. Data were reconstructed using filtered backprojection for conventional SPECT and ordered-subset conjugate gradient minimization for IQ•SPECT. End-systolic volume, end-diastolic volume, and LVEF were calculated using quantitative gated SPECT (QGS) and cardioREPO software. We compared the LVEF from gated myocardial perfusion SPECT to that from echocardiographic measurements. Results: End-diastolic volume, end-systolic volume, and LVEF as obtained from conventional SPECT, IQ•SPECT, and echocardiography showed a good to excellent correlation regardless of whether they were calculated using QGS or using cardioREPO. Although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (65.4% ± 13.8% vs. 68.4% ± 15.2%) ( P = 0.0002), LVEF calculated using cardioREPO did not (69.5% ± 10.6% vs. 69.5% ± 11.0%). Likewise, although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (75.0 ± 9.6 vs. 79.5 ± 8.3) ( P = 0.0005), LVEF calculated using cardioREPO did not (72.3% ± 9.0% vs. 74.3% ± 8.3%). Conclusion: In small-heart patients, the difference in LVEF between IQ•SPECT and conventional SPECT was less when calculated using cardioREPO than when calculated using QGS. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Initial assessment of hearing loss using a mobile application for audiological evaluation.

    PubMed

    Derin, S; Cam, O H; Beydilli, H; Acar, E; Elicora, S S; Sahan, M

    2016-03-01

    This study aimed to compare an Apple iOS mobile operating system application for audiological evaluation with conventional audiometry, and to determine its accuracy and reliability in the initial evaluation of hearing loss. The study comprised 32 patients (16 females) diagnosed with hearing loss. The patients were first evaluated with conventional audiometry and the degree of hearing loss was recorded. Then they underwent a smartphone-based hearing test and the data were compared using Cohen's kappa analysis. Patients' mean age was 53.59 ± 18.01 years (range, 19-85 years). The mobile phone audiometry results for 39 of the 64 ears were fully compatible with the conventional audiometry results. There was a statistically significant concordant relationship between the two sets of audiometry results (p < 0.05). Ear Trumpet version 1.0.2 is a compact and simple mobile application on the Apple iPhone 5 that can measure hearing loss with reliable results.

  6. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

    PubMed

    Yadav, Sucheta; Thukral, Anu; Sankar, M Jeeva; Sreenivas, V; Deorari, Ashok K; Paul, Vinod K; Agarwal, Ramesh

    2012-09-01

    To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants. Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation. Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35). The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.

  7. Progressive changes in patients with skeletal Class III malocclusion treated by 2-jaw surgery with minimal and conventional presurgical orthodontics: A comparative study.

    PubMed

    Zhou, Yang; Li, Zili; Wang, Xiaoxia; Zou, Bingshuang; Zhou, Yanheng

    2016-02-01

    In this study, we aimed to compare treatment efficacy and postsurgical stability between minimal presurgical orthodontics and conventional presurgical orthodontics for patients with skeletal Class III malocclusion. Forty patients received minimal presurgical orthodontics (n = 20) or conventional presurgical orthodontics (n = 20). Lateral cephalograms were obtained before treatment, before orthognathic surgery, and at 1 week, 3 months, 6 months, and 12 months after surgery. Changes of overjet and mandibular incisal angle before surgery were greater in the conventional presurgical orthodontics group than in the minimal presurgical orthodontics group. Postsurgical horizontal changes in Points A and B, overjet, and mandibular incisal angle showed significant differences among the time points. Most of the horizontal and vertical relapses in the maxilla and the mandible occurred within the first 6 months in both groups. Minimal presurgical orthodontics and conventional presurgical orthodontics showed similar extents and directions of skeletal changes in patients with Class III malocclusion. However, orthodontists and surgeons should preoperatively consider the postsurgical counterclockwise rotation of the mandible when using minimal presurgical orthodontics. Close and frequent observations are recommended in the early postsurgical stages. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Conventional versus ultrasound-assisted liposuction in gynaecomastia surgery: a 13-year review.

    PubMed

    Wong, Kai Yuen; Malata, Charles M

    2014-07-01

    Numerous surgical techniques exist for gynaecomastia treatment. Although ultrasound-assisted liposuction (UAL) is thought to be more effective than conventional liposuction, to date there remains no objective and direct comparison of the two modalities. Hence, a comparative study was performed of a single surgeon's experience over 13 years using two definitive parameters, namely intraoperative conversion to open excision and postoperative revisional surgery rates. All gynaecomastia patients treated with UAL or conventional liposuction (1999-2012) were retrospectively studied. UAL was only available in the private sector and was used for all such patients with no other selection or exclusion criteria. A total of 219 patients (384 breasts) with a mean age of 29 years (range 12-74) were evaluated. UAL was utilised in 24% of breasts (47 patients, 91 breasts). Compared with conventional liposuction, UAL had significantly lower rates of intraoperative conversion to open excision (25% vs. 39%; p<0.05) and postoperative revision (2% vs. 19%; p<0.001) using Fisher's exact test. The haematoma rate for each technique was 1%. UAL is a more effective treatment modality for gynaecomastia than conventional liposuction as determined by intraoperative conversion to open surgery and subsequent need for revision. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Laparoendoscopic single-site surgery (LESS) versus conventional laparoscopic surgery for adnexal preservation: a randomized controlled study

    PubMed Central

    Cho, Yeon Jean; Kim, Mi-La; Lee, Soo Yoon; Lee, Hee Suk; Kim, Joo Myoung; Joo, Kwan Young

    2012-01-01

    Objective To compare the operative outcomes, postoperative pain, and subsequent convalescence after laparoendoscopic single-site surgery (LESS) or conventional laparoscopic surgery for adnexal preservation. Study design From December 2009 to September 2010, 63 patients underwent LESS (n = 33) or a conventional laparoscopic surgery (n = 30) for cyst enucleation. The overall operative outcomes including postoperative pain measurement using the visual analog scale (VAS) were evaluated (time points 6, 24, and 24 hours). The convalescence data included data obtained from questionnaires on the need for analgesics and on patient-reported time to recovery end points. Results The preoperative characteristics did not significantly differ between the two groups. The postoperative hemoglobin drop was higher in the LESS group than in the conventional laparoscopic surgery group (P = 0.048). Postoperative pain at each VAS time point, oral analgesic requirement, intramuscular analgesic requirement, and the number of days until return to work were similar in both groups. Conclusion In adnexa-preserving surgery performed in reproductive-age women, the operative outcomes, including satisfaction of the patients and convalescence after surgery, are comparable for LESS and conventional laparoscopy. LESS may be a feasible and a promising alternative method for scarless abdominal surgery in the treatment of young women with adnexal cysts PMID:22448110

  10. A prospective, split-face, double-blinded, randomized study of the efficacy and safety of a fractional 1064-nm Q-switched Nd:YAG laser for photoaging-associated mottled pigmentation in Asian skin.

    PubMed

    Won, Kwang Hee; Lee, Sang Hyung; Lee, Mi Hye; Rhee, Do-Young; Yeo, Un-Cheol; Chang, Sung Eun

    2016-11-01

    Laser toning using low-fluence 1064-nm Q-switched neodymium-doped yttrium aluminum laser (QSNY) has gained popularity in the treatment of photoaging-associated mottled pigmentation (PMP). However, hypopigmentation or lack of efficacy has been reported depending on the fluences used. To compare a novel fractional 1064-nm QSNY with conventional 1064-nm QSNY for the treatment of photoaging-associated mottled pigmentary lesions except epidermal lesions of lentigines and freckles through a randomized, split-face, double-blind study. Thirteen Asian women were treated every week for 6 weeks with fractional 1064-nm QSNY on one side of the face and conventional 1064-nm QSNY on the other side. We evaluated the pigmentation area and severity index (PSI), melanin index, erythema index, and the patient's global assessment of improvement. At three months post-treatment, the PSI score improved compared with baseline, by 14.48% on the conventional 1064-nm QSNY side and 21.81% on the fractional 1064-nm QSNY side. Both groups showed improvements in the melanin index. Both fractional 1064-nm QSNY and strictly low-fluence conventional 1064-nm QSNY are moderately effective against PMP and other photoaging signs. Fractional laser toning shows better subjective outcomes than conventional toning.

  11. Invited review: organic and conventionally produced milk-an evaluation of factors influencing milk composition.

    PubMed

    Schwendel, B H; Wester, T J; Morel, P C H; Tavendale, M H; Deadman, C; Shadbolt, N M; Otter, D E

    2015-02-01

    Consumer perception of organic cow milk is associated with the assumption that organic milk differs from conventionally produced milk. The value associated with this difference justifies the premium retail price for organic milk. It includes the perceptions that organic dairy farming is kinder to the environment, animals, and people; that organic milk products are produced without the use of antibiotics, added hormones, synthetic chemicals, and genetic modification; and that they may have potential benefits for human health. Controlled studies investigating whether differences exist between organic and conventionally produced milk have so far been largely equivocal due principally to the complexity of the research question and the number of factors that can influence milk composition. A main complication is that farming practices and their effects differ depending on country, region, year, and season between and within organic and conventional systems. Factors influencing milk composition (e.g., diet, breed, and stage of lactation) have been studied individually, whereas interactions between multiple factors have been largely ignored. Studies that fail to consider that factors other than the farming system (organic vs. conventional) could have caused or contributed to the reported differences in milk composition make it impossible to determine whether a system-related difference exists between organic and conventional milk. Milk fatty acid composition has been a central research area when comparing organic and conventional milk largely because the milk fatty acid profile responds rapidly and is very sensitive to changes in diet. Consequently, the effect of farming practices (high input vs. low input) rather than farming system (organic vs. conventional) determines milk fatty acid profile, and similar results are seen between low-input organic and low-input conventional milks. This confounds our ability to develop an analytical method to distinguish organic from conventionally produced milk and provide product verification. Lack of research on interactions between several influential factors and differences in trial complexity and consistency between studies (e.g., sampling period, sample size, reporting of experimental conditions) complicate data interpretation and prevent us from making unequivocal conclusions. The first part of this review provides a detailed summary of individual factors known to influence milk composition. The second part presents an overview of studies that have compared organic and conventional milk and discusses their findings within the framework of the various factors presented in part one. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. WE-FG-BRA-05: Potential Clinical Benefit of LINAC Flattening-Filter-Free (FFF) Mode - Improvement of Treatment Therapeutic Ratio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, S; Department of Biomedical Engineering, University of North Carolina- Chapel Hill/ North Carolina State University, Chapel Hill, North Carolina; Lineberger Clinical Cancer Center, University of North Carolina, Chapel Hill, NC

    Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression andmore » cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.« less

  13. Comparison of a conventional and nested PCR for diagnostic confirmation and genotyping of Orientia tsutsugamushi.

    PubMed

    Janardhanan, Jeshina; Prakash, John Antony Jude; Abraham, Ooriapadickal C; Varghese, George M

    2014-05-01

    A nested polymerase chain reaction (PCR) targeting the 56-kDa antigen gene is currently the most commonly used molecular technique for confirmation of scrub typhus and genotyping of Orientia tsutsugamushi. In this study, we have compared the commonly used nested PCR (N-PCR) with a single-step conventional PCR (C-PCR) for amplification and genotyping. Eschar samples collected from 24 patients with scrub typhus confirmed by IgM enzyme-linked immunosorbent assay were used for DNA extraction following which amplifications were carried out using nested and C-PCR methods. The amplicons were sequenced and compared to other sequences in the database using BLAST. Conventional PCR showed a high positivity rate of 95.8% compared to the 75% observed using N-PCR. On sequence analysis, the N-PCR amplified region showed more variation among strains than the C-PCR amplified region. The C-PCR, which is more economical, provided faster and better results compared to N-PCR. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Preliminary design optimization of joined-wing aircraft

    NASA Technical Reports Server (NTRS)

    Gallman, John W.; Kroo, Ilan M.; Smith, Stephen C.

    1990-01-01

    The joined wing is an innovative aircraft configuration that has a its tail connected to the wing forming a diamond shape in both top and plan view. This geometric arrangement utilizes the tail for both pitch control and as a structural support for the wing. Several researchers have studied this configuration and predicted significant reductions in trimmed drag or structural weight when compared with a conventional T-tail configuration. Kroo et al. compared the cruise drag of joined wings with conventional designs of the same lifting-surface area and structural weight. This study showed an 11 percent reduction in cruise drag for the lifting system of a joined wing. Although this reduction in cruise drag is significant, a complete design study is needed before any economic savings can be claimed for a joined-wing transport. Mission constraints, such as runway length, could increase the wing area and eliminate potential drag savings. Since other design codes do not accurately represent the interaction between structures and aerodynamics for joined wings, we developed a new design code for this study. The aerodynamic and structural analyses in this study are significantly more sophisticated than those used in most conventional design codes. This sophistication was needed to predict the aerodynamic interference between the wing and tail and the stresses in the truss-like structure. This paper describes these analysis methods, discusses some problems encountered when applying the numerical optimizer NPSOL, and compares optimum joined wings with conventional aircraft on the basis of cruise drag, lifting surface weight, and direct operating cost (DOC).

  15. Evidence of variable bacterial colonization on coloured elastomeric ligatures during orthodontic treatment: An intermodular comparative study.

    PubMed

    Sharma, Ravish; Sharma, Kavita; Sawhney, Rajesh

    2018-03-01

    Besides, other factors, the choice of materials used as orthodontic ligatures could be one of the many tools to counter the effects of microbial adhesion, that culminates into dental ailments. Therefore, we assessed bacterial adhesion on elastomeric ligatures with special reference to coloured elastomeric rings during orthodontic treatment. A split mouth study, involving 240 samples of different elastomeric ligatures from forty orthodontic patients possessing good oral hygiene was carried out. The archwire was ligated to the brackets on both arches with elastomeric rings (superslick, clear transparent , blue and pink) at predetermined quadrants. After six weeks, ligatures from second premolars were removed and processed for bacterial enumeration using standard techniques. Bacterial counts were also determined for stimulated saliva samples taken at 0 and 6 weeks. A statistically significant difference in bacterial counts was obtained amongst different elastomeric modules used. Maximum bacterial counts were found on conventional pigmented elastomeric modules, followed by Superslick module and clear module. More number of bacteria associated with the conventional pink as compared to the conventional blue pigmented modules, however it was not statistically significant. The three bacterial genera Streptococcus Staphylococcus and Aerobic Lactobacilli adhered to elastomeric modules in following predominant pattern i.e. Conventional pink>Conventional Blue>Superslick>Clear. The studies evidenced colour and material dependent bacterial colonization on orthodontic modules and could be an indicator of bacterial biofilm forming potential based on surface chemistries and a clinically efficacious tool to redesign conventional and modified elastomeric rings as orthodontic ligation accessories. Key words: Bacterial colonization, biofilm, coloured elastomers, orthodontic ligatures.

  16. Primary thoracoscopic treatment of empyema in children.

    PubMed

    Cohen, Gordon; Hjortdal, Vibeke; Ricci, Marco; Jaffe, Adam; Wallis, Colin; Dinwiddie, Robert; Elliott, Martin J; de Leval, Marc R

    2003-01-01

    The optimal treatment of pediatric empyema remains controversial. The objective of this study is to compare the use of conventional management versus primary thoracoscopic drainage and decortication in children with empyema. Conventional management has consisted of chest drain insertion under general anesthesia plus intravenous antibiotics. Thoracoscopic drainage and decortication has consisted of primary thoracoscopic drainage and decortication plus antibiotics. The clinical course of 54 patients treated conventionally between 1989 and 1997 was compared with that of 21 patients treated by means of thoracoscopic drainage and decortication between September 2000 and September 2001. Results of the study demonstrated that patients in the drainage-decortication group had fewer invasive interventions per patient than those in the conventional management group (1.0 vs 1.26). Patients undergoing thoracoscopic drainage and decortication also had significantly shorter durations of intravenous antibiotic therapy (7.6 +/- 1.2 vs 18.2 +/- 7.5 days), chest tube drainage (4.0 +/- 0.5 vs 10.2 +/- 6.1 days), and hospital stays (7.4 +/- 0.8 vs 15.4 +/- 7.4). Moreover, there were no open thoracotomies and decortications in the thoracoscopic drainage and decortication group, whereas in the conventional management group 39% (21/54) of patients underwent an open procedure. Although the 2 groups were not prospectively randomized and they were treated in different time periods, the results of this study support the use of thoracoscopic surgery as the primary therapeutic modality in children presenting with pleural empyema. This strategy appears to offer significant benefits over conventional treatment in terms of duration of treatment and the need for more invasive surgery.

  17. A NEW METHOD OF SWEAT TESTING: THE CF QUANTUM® SWEAT TEST

    PubMed Central

    Rock, Michael J.; Makholm, Linda; Eickhoff, Jens

    2015-01-01

    Background Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Methods Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. Results The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97–0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94–100%) and 96% (95% confidence interval: 89–99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%)(p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. Conclusions The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. PMID:24862724

  18. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    PubMed

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Chest CT window settings with multiscale adaptive histogram equalization: pilot study.

    PubMed

    Fayad, Laura M; Jin, Yinpeng; Laine, Andrew F; Berkmen, Yahya M; Pearson, Gregory D; Freedman, Benjamin; Van Heertum, Ronald

    2002-06-01

    Multiscale adaptive histogram equalization (MAHE), a wavelet-based algorithm, was investigated as a method of automatic simultaneous display of the full dynamic contrast range of a computed tomographic image. Interpretation times were significantly lower for MAHE-enhanced images compared with those for conventionally displayed images. Diagnostic accuracy, however, was insufficient in this pilot study to allow recommendation of MAHE as a replacement for conventional window display.

  20. A Comparative Study of the Effects of the Neurocognitive-Based Model and the Conventional Model on Learner Attention, Working Memory and Mood

    ERIC Educational Resources Information Center

    Srikoon, Sanit; Bunterm, Tassanee; Nethanomsak, Teerachai; Ngang, Tang Keow

    2017-01-01

    Purpose: The attention, working memory, and mood of learners are the most important abilities in the learning process. This study was concerned with the comparison of contextualized attention, working memory, and mood through a neurocognitive-based model (5P) and a conventional model (5E). It sought to examine the significant change in attention,…

  1. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    PubMed

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  2. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions.

    PubMed

    Ender, Andreas; Attin, Thomas; Mehl, Albert

    2016-03-01

    Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; digitized scannable vinylsiloxanether, VSES-D; and irreversible hydrocolloid, ALG) and 7 digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; Lava COS, LAV; Lava True Definition Scanner, T-Def; 3Shape Trios, TRI; and 3Shape Trios Color, TRC) techniques. Impressions were made 3 times each in 5 participants (N=15). The impressions were then compared within and between the test groups. The cast surfaces were measured point-to-point using the signed nearest neighbor method. Precision was calculated from the (90%-10%)/2 percentile value. The precision ranged from 12.3 μm (VSE) to 167.2 μm (ALG), with the highest precision in the VSE and VSES groups. The deviation pattern varied distinctly according to the impression method. Conventional impressions showed the highest accuracy across the complete dental arch in all groups, except for the ALG group. Conventional and digital impression methods differ significantly in the complete-arch accuracy. Digital impression systems had higher local deviations within the complete arch cast; however, they achieve equal and higher precision than some conventional impression materials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. The biomechanical and perceptual influence of chain resistance on the performance of the olympic clean.

    PubMed

    Berning, Joseph M; Coker, Cheryl A; Briggs, Doug

    2008-03-01

    Proponents of chain training suggest that using chains hung from the ends of barbells rather than using conventional barbells alone enhances strength, power, and neuromuscular adaptations. The purpose of this study was to determine whether a conventional barbell with chains compared to a conventional barbell without chains would affect the performance of an Olympic Clean. The subjects were also asked regarding their perception of how chains affected their lifting. Four male and 3 female competitive weightlifters who used chains as part of their training participated in the study. The testing protocol compared the subjects' lifting 80% and 85% of their 1 repetition maximum (1RM) using conventional barbells and their lifting 80% and 85% of their 1RM using chains (75% conventional barbells + 5% chains and 80% conventional barbells + 5% chains, respectively). Video analysis evaluated the bar's vertical displacement and velocity and the rate of force production. Vertical ground reaction forces for the first-pull, unweighting, and second-pull phases of the lift were evaluated by using a force plate. After testing, the subjects completed a 2-item questionnaire asking individual perception of the effects of the chains. The results showed no significant difference for condition for any of the variables examined. In contrast, all subjects perceived that the chains required a greater effort. In conclusion, the results indicated that the addition of chains provided no greater value over lifting conventional barbells alone in the performance of the Olympic Clean, although the subjects perceived the chains to have a positive effect.

  4. Circumferential Trabeculotomy Versus Conventional Angle Surgery: Comparing Long-term Surgical Success and Clinical Outcomes in Children With Primary Congenital Glaucoma.

    PubMed

    Neustein, Rebecca F; Beck, Allen D

    2017-11-01

    This study compares the long-term efficacy of circumferential trabeculotomy to that of conventional angle surgeries in primary congenital glaucoma (PCG), as judged by glaucoma and visual outcomes. Retrospective observational case series. Setting: Emory Eye Center, Atlanta, Georgia. This was a single-institution retrospective study involving children with PCG who underwent circumferential trabeculotomy, standard trabeculotomy, or goniotomy with ≥2-year follow-up. Postoperative success (intraocular pressure [IOP] < 22 mm Hg ± glaucoma medications, without glaucoma progression/additional IOP-lowering surgery), Snellen-equivalent visual acuity (VA), and IOP at last follow-up. Kaplan-Meier method estimated the probability of glaucoma control vs time postoperatively, and values were compared between angle surgery cohorts using Wilcoxon signed rank tests, Mann-Whitney U tests, and Fisher exact tests. Included were 58 eyes (33 children) after circumferential trabeculotomy and 42 eyes (27 children) after standard trabeculotomy/goniotomy, with mean follow-up of 7.2 ± 4.0 and 8.2 ± 4.5 years, respectively. Postoperative success at last follow-up in the circumferential vs conventional cohorts was 81% (47 of 58 eyes) vs 31% (13 of 42 eyes) (P < .0001). At last follow-up, the circumferential cohort had better median VA than the conventional cohort (20/30 (interquartile range [IQR] 20/25 to 20/70) vs 20/70 (IQR 20/40 to 20/200), P = .009), required fewer glaucoma medications (0.55 ± 1.2 vs 1.61 ± 1.51, P < .0001), had lower IOP in first operated eye (15.2 ± 3.6 vs 18.2 ± 7.0, P = .048), and had comparable incidence of devastating complications (P = .065). In this retrospective study, circumferential trabeculotomy afforded better long-term success and visual outcomes than conventional angle surgery for children with PCG. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Nicotine Levels and Presence of Selected Tobacco-Derived Toxins in Tobacco Flavoured Electronic Cigarette Refill Liquids

    PubMed Central

    Farsalinos, Konstantinos E.; Gillman, I. Gene; Melvin, Matt S.; Paolantonio, Amelia R.; Gardow, Wendy J.; Humphries, Kathy E.; Brown, Sherri E.; Poulas, Konstantinos; Voudris, Vassilis

    2015-01-01

    Background. Some electronic cigarette (EC) liquids of tobacco flavour contain extracts of cured tobacco leaves produced by a process of solvent extraction and steeping. These are commonly called Natural Extract of Tobacco (NET) liquids. The purpose of the study was to evaluate nicotine levels and the presence of tobacco-derived toxins in tobacco-flavoured conventional and NET liquids. Methods. Twenty-one samples (10 conventional and 11 NET liquids) were obtained from the US and Greek market. Nicotine levels were measured and compared with labelled values. The levels of tobacco-derived chemicals were compared with literature data on tobacco products. Results. Twelve samples had nicotine levels within 10% of the labelled value. Inconsistency ranged from −21% to 22.1%, with no difference observed between conventional and NET liquids. Tobacco-specific nitrosamines (TSNAs) were present in all samples at ng/mL levels. Nitrates were present almost exclusively in NET liquids. Acetaldehyde was present predominantly in conventional liquids while formaldehyde was detected in almost all EC liquids at trace levels. Phenols were present in trace amounts, mostly in NET liquids. Total TSNAs and nitrate, which are derived from the tobacco plant, were present at levels 200–300 times lower in 1 mL of NET liquids compared to 1 gram of tobacco products. Conclusions. NET liquids contained higher levels of phenols and nitrates, but lower levels of acetaldehyde compared to conventional EC liquids. The lower levels of tobacco-derived toxins found in NET liquids compared to tobacco products indicate that the extraction process used to make these products did not transfer a significant amount of toxins to the NET. Overall, all EC liquids contained far lower (by 2–3 orders of magnitude) levels of the tobacco-derived toxins compared to tobacco products. PMID:25811768

  6. Nicotine levels and presence of selected tobacco-derived toxins in tobacco flavoured electronic cigarette refill liquids.

    PubMed

    Farsalinos, Konstantinos E; Gillman, I Gene; Melvin, Matt S; Paolantonio, Amelia R; Gardow, Wendy J; Humphries, Kathy E; Brown, Sherri E; Poulas, Konstantinos; Voudris, Vassilis

    2015-03-24

    Some electronic cigarette (EC) liquids of tobacco flavour contain extracts of cured tobacco leaves produced by a process of solvent extraction and steeping. These are commonly called Natural Extract of Tobacco (NET) liquids. The purpose of the study was to evaluate nicotine levels and the presence of tobacco-derived toxins in tobacco-flavoured conventional and NET liquids. Twenty-one samples (10 conventional and 11 NET liquids) were obtained from the US and Greek market. Nicotine levels were measured and compared with labelled values. The levels of tobacco-derived chemicals were compared with literature data on tobacco products. Twelve samples had nicotine levels within 10% of the labelled value. Inconsistency ranged from -21% to 22.1%, with no difference observed between conventional and NET liquids. Tobacco-specific nitrosamines (TSNAs) were present in all samples at ng/mL levels. Nitrates were present almost exclusively in NET liquids. Acetaldehyde was present predominantly in conventional liquids while formaldehyde was detected in almost all EC liquids at trace levels. Phenols were present in trace amounts, mostly in NET liquids. Total TSNAs and nitrate, which are derived from the tobacco plant, were present at levels 200-300 times lower in 1 mL of NET liquids compared to 1 gram of tobacco products. NET liquids contained higher levels of phenols and nitrates, but lower levels of acetaldehyde compared to conventional EC liquids. The lower levels of tobacco-derived toxins found in NET liquids compared to tobacco products indicate that the extraction process used to make these products did not transfer a significant amount of toxins to the NET. Overall, all EC liquids contained far lower (by 2-3 orders of magnitude) levels of the tobacco-derived toxins compared to tobacco products.

  7. Extended-hours hemodialysis is associated with lower mortality risk in patients with end-stage renal disease.

    PubMed

    Rivara, Matthew B; Adams, Scott V; Kuttykrishnan, Sooraj; Kalantar-Zadeh, Kamyar; Arah, Onyebuchi A; Cheung, Alfred K; Katz, Ronit; Molnar, Miklos Z; Ravel, Vanessa; Soohoo, Melissa; Streja, Elani; Himmelfarb, Jonathan; Mehrotra, Rajnish

    2016-12-01

    Extended-hours hemodialysis offers substantially longer treatment time compared to conventional hemodialysis schedules and is associated with improved fluid and electrolyte control and favorable cardiac remodeling. However, whether extended-hours hemodialysis improves survival remains unclear. Therefore, we determined the association between extended-hours compared to conventional hemodialysis and the risk of all-cause mortality in a nationally representative cohort of patients initiating maintenance dialysis in the United States from 2007 to 2011. Survival analyses using causal inference modeling with marginal structural models were performed to compare mortality risk among 1206 individuals undergoing thrice weekly extended-hours hemodialysis or 111,707 patients receiving conventional hemodialysis treatments. The average treatment time per session for extended-hours hemodialysis was 399 minutes compared to 211 minutes for conventional therapy. The crude mortality rate with extended-hours hemodialysis was 6.4 deaths per 100 patient-years compared with 14.7 deaths per 100 patient-years for conventional hemodialysis. In the primary analysis, patients treated with extended-hours hemodialysis had a 33% lower adjusted risk of death compared to those who were treated with a conventional regimen (95% confidence interval: 7% to 51%). Additional analyses accounting for analytical assumptions regarding exposure and outcome, facility-level confounders, and prior modality history were similar. Thus, in this large nationally representative cohort, treatment with extended-hours hemodialysis was associated with a lower risk for mortality compared to treatment with conventional in-center therapy. Adequately powered randomized clinical trials comparing extended-hours to conventional hemodialysis are required to confirm these findings. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  8. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy.

    PubMed

    Giada, Franco; Gulizia, Michele; Francese, Maura; Croci, Francesco; Santangelo, Lucio; Santomauro, Maurizio; Occhetta, Eraldo; Menozzi, Carlo; Raviele, Antonio

    2007-05-15

    The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations. In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis. We studied 50 patients with infrequent (< or =1 episode/month), sustained (>1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated. A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012). In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.

  9. Comparison of machinability of manganese alloyed austempered ductile iron produced using conventional and two step austempering processes

    NASA Astrophysics Data System (ADS)

    Hegde, Ananda; Sharma, Sathyashankara

    2018-05-01

    Austempered Ductile Iron (ADI) is a revolutionary material with high strength and hardness combined with optimum ductility and toughness. The discovery of two step austempering process has lead to the superior combination of all the mechanical properties. However, because of the high strength and hardness of ADI, there is a concern regarding its machinability. In the present study, machinability of ADI produced using conventional and two step heat treatment processes is assessed using tool life and the surface roughness. Speed, feed and depth of cut are considered as the machining parameters in the dry turning operation. The machinability results along with the mechanical properties are compared for ADI produced using both conventional and two step austempering processes. The results have shown that two step austempering process has produced better toughness with good hardness and strength without sacrificing ductility. Addition of 0.64 wt% manganese did not cause any detrimental effect on the machinability of ADI, both in conventional and two step processes. Marginal improvement in tool life and surface roughness were observed in two step process compared to that with conventional process.

  10. Transdermal delivery of raloxifene HCl via ethosomal system: Formulation, advanced characterizations and pharmacokinetic evaluation.

    PubMed

    Mahmood, Syed; Mandal, Uttam Kumar; Chatterjee, Bappaditya

    2018-05-05

    Raloxifene HCl belongs to a class of selective estrogen receptor modulators (SERMs) which is used for the management of breast cancer. The major problem reported with raloxifene is its poor bioavailability which is only up to 2%. The main objective of the present work was to formulate raloxifene loaded ethosomal preparation for transdermal application and compare it with an oral formulation of the drug. Five ethosomal formulations with different concentrations of ethanol and a conventional liposomes formulation were prepared by rotary evaporation method. The prepared systems were characterised by high resolution transmission electron microscopy (HRTEM), force emission electron microscopy (FESEM), atomic force microscopy (AFM), X-ray diffraction (XRD) and 31 P NMR study. All these advanced characterization study established that the ethosome formulation was well defined by its size, shape and its bilayer formation. Transdermal flux of the optimized ethosome formulation was 22.14 ± 0.83 µg/ml/cm 2 which was 21 times higher when compared to the conventional liposomes. Confocal microscopy study revealed an enhanced permeation of coumarin-6 dye loaded ethosomes to much deeper layers of skin when compared with conventional liposomes. The gel was found to be pseudoplastic with elastic behaviour. In-vivo studies on rats showed a higher bioavailability of RXL (157% times) for ethosomal formulation when compared with the oral formulation. In conclusion, RXL loaded ethosomal formulation via transdermal route showed superior drug delivery properties as compared to oral formulation. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Feasibility of light-emitting diode uses for annular reactor inner-coated with TiO2 or nitrogen-doped TiO2 for control of dimethyl sulfide.

    PubMed

    Jo, Wan-Kuen; Eun, Sung-Soo; Shin, Seung-Ho

    2011-01-01

    Limited environmental pollutants have only been investigated for the feasibility of light-emitting diodes (LED) uses in photocatalytic decomposition (PD). The present study investigated the applicability of LEDs for annular photocatalytic reactors by comparing PD efficiencies of dimethyl sulfide (DMS), which has not been investigated with any LED-PD system, between photocatalytic systems utilizing conventional and various LED lamps with different wavelengths. A conventional 8 W UV/TiO(2) system exhibited a higher DMS PD efficiency as compared with UV-LED/TiO(2) system. Similarly, a conventional 8 W visible-lamp/N-enhanced TiO(2) (NET) system exhibited a higher PD efficiency as compared with six visible-LED/NET systems. However, the ratios of PD efficiency to the electric power consumption were rather high for the photocatalytic systems using UV- or visible-LED lamps, except for two LED lamps (yellow- and red-LED lamps), compared to the photocatalytic systems using conventional lamps. For the photocatalytic systems using LEDs, lower flow rates and input concentrations and shorter hydraulic diameters exhibited higher DMS PD efficiencies. An Fourier-transformation infrared analysis suggested no significant absorption of byproducts on the catalyst surface. Consequently, it was suggested that LEDs can still be energy-efficiently utilized as alternative light sources for the PD of DMS, under the operational conditions used in this study. © 2011 The Authors. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  12. An innovative method of ocular prosthesis fabrication by bio-CAD and rapid 3-D printing technology: A pilot study.

    PubMed

    Alam, Md Shahid; Sugavaneswaran, M; Arumaikkannu, G; Mukherjee, Bipasha

    2017-08-01

    Ocular prosthesis is either a readymade stock shell or custom made prosthesis (CMP). Presently, there is no other technology available, which is either superior or even comparable to the conventional CMP. The present study was designed to fabricate ocular prosthesis using computer aided design (CAD) and rapid manufacturing (RM) technology and to compare it with custom made prosthesis (CMP). The ocular prosthesis prepared by CAD was compared with conventional CMP in terms of time taken for fabrication, weight, cosmesis, comfort, and motility. Two eyes of two patients were included. Computerized tomography scan of wax model of socket was converted into three dimensional format using Materialize Interactive Medical Image Control System (MIMICS)software and further refined. This was given as an input to rapid manufacturing machine (Polyjet 3-D printer). The final painting on prototype was done by an ocularist. The average effective time required for fabrication of CAD prosthesis was 2.5 hours; and weight 2.9 grams. The same for CMP were 10 hours; and 4.4 grams. CAD prosthesis was more comfortable for both the patients. The study demonstrates the first ever attempt of fabricating a complete ocular prosthesis using CAD and rapid manufacturing and comparing it with conventional CMP. This prosthesis takes lesser time for fabrication, and is more comfortable. Studies with larger sample size will be required to further validate this technique.

  13. Effect of chlorhexidine disinfectant on bond strength of glass ionomer cement to dentin using atraumatic restorative treatment.

    PubMed

    Wadenya, Rose; Menon, Sandhya; Mante, Francis

    2011-01-01

    This study investigated the effect of 2% chlorhexidine gluconate (CHX) disinfectant on bond strength (BS) of high-density glass ionomer cement (HDGIC) to dentin following atraumatic restorative treatment (ART) and conventional preparations. Specimens were divided into four groups: Group 1--ART (control); Group 2--ART with CHX disinfection; Group 3--Conventional (control); Group 4--Conventional with CHX disinfection. HDGIC was packed in cylindrical molds placed over flat dentin surfaces; BS was measured after seven days. ART-prepared dentin surfaces disinfected with CHX provided bonding to HDGIC that was comparable to untreated dentin and to conventionally prepared dentin.

  14. Dry-grind processing using amylase corn and superior yeast to reduce the exogenous enzyme requirements in bioethanol production.

    PubMed

    Kumar, Deepak; Singh, Vijay

    2016-01-01

    Conventional corn dry-grind ethanol production process requires exogenous alpha and glucoamylases enzymes to breakdown starch into glucose, which is fermented to ethanol by yeast. This study evaluates the potential use of new genetically engineered corn and yeast, which can eliminate or minimize the use of these external enzymes, improve the economics and process efficiencies, and simplify the process. An approach of in situ ethanol removal during fermentation was also investigated for its potential to improve the efficiency of high-solid fermentation, which can significantly reduce the downstream ethanol and co-product recovery cost. The fermentation of amylase corn (producing endogenous α-amylase) using conventional yeast and no addition of exogenous α-amylase resulted in ethanol concentration of 4.1 % higher compared to control treatment (conventional corn using exogenous α-amylase). Conventional corn processed with exogenous α-amylase and superior yeast (producing glucoamylase or GA) with no exogenous glucoamylase addition resulted in ethanol concentration similar to control treatment (conventional yeast with exogenous glucoamylase addition). Combination of amylase corn and superior yeast required only 25 % of recommended glucoamylase dose to complete fermentation and achieve ethanol concentration and yield similar to control treatment (conventional corn with exogenous α-amylase, conventional yeast with exogenous glucoamylase). Use of superior yeast with 50 % GA addition resulted in similar increases in yield for conventional or amylase corn of approximately 7 % compared to that of control treatment. Combination of amylase corn, superior yeast, and in situ ethanol removal resulted in a process that allowed complete fermentation of 40 % slurry solids with only 50 % of exogenous GA enzyme requirements and 64.6 % higher ethanol yield compared to that of conventional process. Use of amylase corn and superior yeast in the dry-grind processing industry can reduce the total external enzyme usage by more than 80 %, and combining their use with in situ removal of ethanol during fermentation allows efficient high-solid fermentation.

  15. Do aggregate stability and soil organic matter content increase following organic inputs?

    NASA Astrophysics Data System (ADS)

    Lehtinen, Taru; Gísladóttir, Guðrún; van Leeuwen, Jeroen P.; Bloem, Jaap; Steffens, Markus; Vala Ragnarsdóttir, Kristin

    2014-05-01

    Agriculture is facing several challenges such as loss of soil organic matter (SOM); thus, sustainable farming management practices are needed. Organic farming is growing as an alternative to conventional farming; in Iceland approximately 1% and in Austria 16% of utilized agricultural area is under organic farming practice. We analyzed the effect of different farming practices (organic, and conventional) on soil physicochemical and microbiological properties in grassland soils in Iceland and cropland soils in Austria. Organic farms differed from conventional farms by absence of chemical fertilizers and pesticide use. At these farms, we investigated soil physicochemical (e.g. soil texture, pH, CAL-extractable P and K) and microbiological properties (fungal and bacterial biomass and activity). The effects of farming practices on soil macroaggregate stability and SOM quantity, quality and distribution between different fractions were studied following a density fractionation. In Iceland, we sampled six grassland sites on Brown (BA) and Histic (HA) Andosols; two sites on extensively managed grasslands, two sites under organic and two sites under conventional farming practice. In Austria, we sampled four cropland sites on Haplic Chernozems; two sites under organic and two sites under conventional farming practice. We found significantly higher macroaggregate stability in the organic compared to the conventional grasslands in Iceland. In contrast, slightly higher macroaggregation in conventional compared to the organic farming practice was found in croplands in Austria, although the difference was not significant. Macroaggregates were positively correlated with fungal biomass in Iceland, and with Feo and fungal activity in Austria. In Austria, SOM content and nutrient status (except for lower CAL-extractable P at one site) were similar between organic and conventional farms. Our results show that the organic inputs may have enhanced macroaggregation in organic farming practice compared to conventional in the permanent grassland soils in Iceland but were only enough to maintain the SOM content and macroaggregation in the cropland soils in Austria.

  16. Beyond Epilepsy: How Can Quantitative Electroencephalography Improve Conventional Electroencephalography Findings? A Systematic Review of Comparative EEG Studies.

    PubMed

    Martins, Cassio Henrique Taques; Assunção, Catarina De Marchi

    2018-01-01

    It is a fundamental element in both research and clinical applications of electroencephalography to know the frequency composition of brain electrical activity. The quantitative analysis of brain electrical activity uses computer resources to evaluate the electroencephalography and allows quantification of the data. The contribution of the quantitative perspective is unique, since conventional electroencephalography based on the visual examination of the tracing is not as objective. A systematic review was performed on the MEDLINE database in October 2017. The authors independently analyzed the studies, by title and abstract, and selected articles that met the inclusion criteria: comparative studies, not older than 30 years, that compared the use of conventional electroencephalogram (EEG) with the use of quantitative electroencephalogram (QEEG) in the English language. One hundred twelve articles were automatically selected by the MEDLINE search engine, but only six met the above criteria. The review found that given a 95% confidence interval, QEEG had no statistically higher sensitivity than EEG in four of the six studies reviewed. However, these results must be viewed with appropriate caution, particularly as groups in between studies were not matched on important variables such as gender, age, type of illness, recovery stage, and treatment. The authors' findings in this systematic review are suggestive of the importance of QEEG as an auxiliary tool to traditional EEG, and as such, justifying further refinement, standardization, and eventually the future execution of a head-to-head prospective study on comparing the two methods.

  17. Comparison of conventional medicine, TCM treatment, and combination of both conventional medicine and TCM treatment for patients with chronic obstructive pulmonary disease: study protocol of a randomized comparative effectiveness research trial.

    PubMed

    Li, Jian-Sheng; Xie, Yang; Li, Su-Yun; Yu, Xue-Qing

    2014-05-01

    Chronic obstructive pulmonary disease (COPD) affects millions worldwide. Although many therapies exist and are being developed to relieve symptoms and reduce mortality, few data are available to understand which of the therapeutic alternatives is the most cost-effective for COPD patients in everyday clinical practice, especially for traditional Chinese medicine (TCM). Comparative effectiveness research can help patients, clinicians, and decision-makers make best informed treatment decisions where such evidence was previously lacking. This study aims to compare the effectiveness and economic evaluation of three treatments: (1) conventional Western medicine; (2) TCM treatments, which have been evaluated and have certain effect; and (3) a combination of both conventional Western medicine and TCM treatments, and then determine which treatment is the most suitable for COPD patients. A multicenter, pragmatic, randomized, controlled trial is adopted. A total of 360 patients will be recruited and randomly assigned to one of the three treatments group, with 120 in each group. Patients in the conventional Western medicine group will be given Salbutamol, Formoterol, Salmeterol/fluticasone, respectively, according to the guidelines. For the TCM group, patients will be given Bufei granule, Bu-Fei Jian-Pi granule, Bu-Fei Yi-Shen granule, and Yi-Qi Zi-Shen granule based on their corresponding TCM syndrome patterns, respectively. For the combination of conventional medicine and TCM treatments group, patients will be given a combination of conventional Western medicine and TCM granules. Treatments in each group are recognized as a whole comprehensive intervention. After the 26-week treatment, another 26 weeks will be followed up. The outcome measures including the frequency and duration of acute exacerbations, lung function, dyspnea, exercise capacity, quality of life, and economic evaluation will be assessed. It is hypothesized that each of the three treatments will have beneficial effects in reducing the frequency and duration of acute exacerbations, improving exercise capacity and psychosocial function of COPD patients. In addition, the combination of conventional medicine and TCM treatments may be most suitable for COPD patients with better effectiveness and economic evaluation. ClinicalTrials.gov NCT01836016.

  18. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery

    PubMed Central

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-01-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser. PMID:29619098

  19. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery.

    PubMed

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-04-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser.

  20. DNA analysis using an integrated microchip for multiplex PCR amplification and electrophoresis for reference samples.

    PubMed

    Le Roux, Delphine; Root, Brian E; Reedy, Carmen R; Hickey, Jeffrey A; Scott, Orion N; Bienvenue, Joan M; Landers, James P; Chassagne, Luc; de Mazancourt, Philippe

    2014-08-19

    A system that automatically performs the PCR amplification and microchip electrophoretic (ME) separation for rapid forensic short tandem repeat (STR) forensic profiling in a single disposable plastic chip is demonstrated. The microchip subassays were optimized to deliver results comparable to conventional benchtop methods. The microchip process was accomplished in sub-90 min compared with >2.5 h for the conventional approach. An infrared laser with a noncontact temperature sensing system was optimized for a 45 min PCR compared with the conventional 90 min amplification time. The separation conditions were optimized using LPA-co-dihexylacrylamide block copolymers specifically designed for microchip separations to achieve accurate DNA size calling in an effective length of 7 cm in a plastic microchip. This effective separation length is less than half of other reports for integrated STR analysis and allows a compact, inexpensive microchip design. This separation quality was maintained when integrated with microchip PCR. Thirty samples were analyzed conventionally and then compared with data generated by the microfluidic chip system. The microfluidic system allele calling was 100% concordant with the conventional process. This study also investigated allelic ladder consistency over time. The PCR-ME genetic profiles were analyzed using binning palettes generated from two sets of allelic ladders run three and six months apart. Using these binning palettes, no allele calling errors were detected in the 30 samples demonstrating that a microfluidic platform can be highly consistent over long periods of time.

  1. Comparative analysis of stress in a new proposal of dental implants.

    PubMed

    Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Macedo, Ana Paula; Shimano, Antonio Carlos; Dos Reis, Andréa Cândido

    2017-08-01

    The purpose of this study was to compare, through photoelastic analysis, the stress distribution around conventional and modified external hexagon (EH) and morse taper (MT) dental implant connections. Four photoelastic models were prepared (n=1): Model 1 - conventional EH cylindrical implant (Ø 4.0mm×11mm - Neodent®), Model 2 - modified EH cylindrical implant, Model 3 - conventional MT Conical implant (Ø 4.3mm×10mm - Neodent®) and Model 4 - modified MT conical implant. 100 and 150N axial and oblique loads (30° tilt) were applied in the devices coupled to the implants. A plane transmission polariscope was used in the analysis of fringes and each position of interest was recorded by a digital camera. The Tardy method was used to quantify the fringe order (n), that calculates the maximum shear stress (τ) value in each selected point. The results showed lower stress concentration in the modified cylindrical implant (EH) compared to the conventional model, with application of 150N axial and 100N oblique loads. Lower stress was observed for the modified conical (MT) implant with the application of 100 and 150N oblique loads, which was not observed for the conventional implant model. The comparative analysis of the models showed that the new design proposal generates good stress distribution, especially in the cervical third, suggesting the preservation of bone tissue in the bone crest region. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparing the Efficacy of Low Dose and Conventional Dose of Oral Isotretinoin in Treatment of Moderate and Severe Acne Vulgaris.

    PubMed

    Faghihi, Gita; Mokhtari, Fatemeh; Fard, Nasrin Motamedi; Motamedi, Narges; Hosseini, Sayed Mohsen

    2017-01-01

    This study was conducted to compare the effect of low-dose isotretinoin with its conventional dose in patients with moderate and severe acne. This was a clinical trial conducted on 60 male and female patients with moderate and severe acne vulgaris. The patients were divided into two treatment groups: 0.5 mg/kg/day isotretinoin capsule and low-dose isotretinoin capsule (0.25 mg/kg/day). Patients in both groups received 6-month treatment. At the end of the 6 th month and 12 th month (6 months after the end of the treatment), they were examined again, and their improvement was determined and compared. The average severity of acne in the two treatment groups did not differ significantly within any of the study periods. The most common side effects were nose dryness in the low-dose group (17%) and hair thinning and loss in the conventional-dose group (33.2%), although all the patients had dry lips. According to the same severity of the acne in two groups in different study periods, as well as fewer side effects and more patients' satisfaction, the low-dose isotretinoin can be considered in the treatment of acne.

  3. Comparing the Efficiency of Two Different Extraction Techniques in Removal of Maxillary Third Molars: A Randomized Controlled Trial.

    PubMed

    Edward, Joseph; Aziz, Mubarak A; Madhu Usha, Arjun; Narayanan, Jyothi K

    2017-12-01

    Extractions are routine procedures in dental surgery. Traditional extraction techniques use a combination of severing the periodontal attachment, luxation with an elevator, and removal with forceps. A new technique of extraction of maxillary third molar is introduced in this study-Joedds technique, which is compared with the conventional technique. One hundred people were included in the study, the people were divided into two groups by means of simple random sampling. In one group conventional technique of maxillary third molar extraction was used and on second Joedds technique was used. Statistical analysis was carried out with student's t test. Analysis of 100 patients based on parameters showed that the novel joedds technique had minimal trauma to surrounding tissues, less tuberosity and root fractures and the time taken for extraction was <2 min while compared to other group of patients. This novel technique has proved to be better than conventional third molar extraction technique, with minimal complications. If Proper selection of cases and right technique are used.

  4. Simulation of introgression of the polled allele into the Holstein breed via conventional breeding versus gene editing

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to simulate the introgression of the polled allele into a dairy cattle population and compare the impact of using the methods of conventional breeding versus gene editing to increase the frequency of the polled allele. The rate of minor allele frequency (MAF) change, ...

  5. The Effectiveness of Programed Instruction Versus the Lecture-Discussion Method of Teaching Basic Metallurgical Concepts.

    ERIC Educational Resources Information Center

    Bockman, David Carl

    The purpose of this study was to compare the conventional lecture-discussion method and an illustrated programed textbook method when teaching a unit of instruction on the basic concepts of metallurgy. The control group used a portion of a conventional textbook accompanied by lecture, chalkboard illustration, and class discussion. The experimental…

  6. Effect of Tillage System, Row Spacing and Herbicide Technologies on Plant Growth and Lint Yield in Cotton

    USDA-ARS?s Scientific Manuscript database

    A field study was conducted from 2004 through 2006 growing seasons at the E.V. Smith Research Center, Field Crops Unit near Shorter, AL, to compare a conventional variety, a glyphosate tolerant variety, and a glufosinate tolerant variety under both the conventional tillage and the conservation tilla...

  7. Nitrous oxide, methane emission, and yield-scaled emission from organically and conventionally managed systems

    USDA-ARS?s Scientific Manuscript database

    There is a gap in empirical greenhouse gas (GHG) data from many regions of the USA including the northern Corn Belt. This study compared nitrous oxide (N2O) emission in diverse, low-tillage conventionally- and organically-managed systems. Both systems had a four-year rotation, mole-knife, strip till...

  8. Colon Cancer Survival With Herbal Medicine and Vitamins Combined With Standard Therapy in a Whole-Systems Approach: Ten-Year Follow-up Data Analyzed With Marginal Structural Models and Propensity Score Methods

    PubMed Central

    McCulloch, Michael; Broffman, Michael; van der Laan, Mark; Hubbard, Alan; Kushi, Lawrence; Abrams, Donald I.; Gao, Jin; Colford, John M.

    2014-01-01

    Although localized colon cancer is often successfully treated with surgery, advanced disease requires aggressive systemic therapy that has lower effectiveness. Approximately 30% to 75% of patients with colon cancer use complementary and alternative medicine (CAM), but there is limited formal evidence of survival efficacy. In a consecutive case series with 10-year follow-up of all colon cancer patients (n = 193) presenting at a San Francisco Bay-Area center for Chinese medicine (Pine Street Clinic, San Anselmo, CA), the authors compared survival in patients choosing short-term treatment lasting the duration of chemotherapy/radiotherapy with those continuing long-term. To put these data into the context of treatment responses seen in conventional medical practice, they also compared survival with Pan-Asian medicine + vitamins (PAM+V) with that of concurrent external controls from Kaiser Permanente Northern California and California Cancer Registries. Kaplan-Meier, traditional Cox regression, and more modern methods were used for causal inference—namely, propensity score and marginal structural models (MSMs), which have not been used before in studies of cancer survival and Chinese herbal medicine. PAM+V combined with conventional therapy, compared with conventional therapy alone, reduced the risk of death in stage I by 95%, stage II by 64%, stage III by 29%, and stage IV by 75%. There was no significant difference between short-term and long-term PAM+V. Combining PAM+V with conventional therapy improved survival, compared with conventional therapy alone, suggesting that prospective trials combining PAM+V with conventional therapy are justified. PMID:21964510

  9. Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

    PubMed

    Tofangchiha, Maryam; Adel, Mamak; Bakhshi, Mahin; Esfehani, Mahsa; Nazeman, Pantea; Ghorbani Elizeyi, Mojgan; Javadi, Amir

    2013-01-01

    Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). The type of monitor does not influence diagnosis of vertical root fractures.

  10. Differences in sheep and goats milk fatty acid profile between conventional and organic farming systems.

    PubMed

    Tsiplakou, Eleni; Kotrotsios, Vaios; Hadjigeorgiou, Ioannis; Zervas, George

    2010-08-01

    The objective of this study was to investigate whether there is a difference in chemical composition and particularly in fatty acid (FA) profile, with emphasis on cis-9, trans-11 CLA, of milk obtained from conventional and organic dairy sheep and goats farms under the farming conditions practiced in Greece. Four dairy sheep and four dairy goat farms, representing common conventional production systems and another four dairy sheep and four dairy goat farms, organically certified, representing organic production and feeding systems were selected from all over Greece. One hundred and sixty two individual milk samples were collected from those farms in January-February 2009, about three months after parturition. The milk samples were analyzed for their main chemical constituents and their FA profile. The results showed that the production system affected milk chemical composition: in particular fat content was lower in the organic sheep and goats milk compared with the corresponding conventional. Milk from organic sheep had higher content in MUFA, PUFA, alpha-LNA, cis-9, trans-11 CLA, and omega-3 FA, whereas in milk from organic goats alpha-LNA and omega-3 FA content was higher than that in conventional one. These differences are, mainly, attributed to different feeding practices used by the two production systems. The results of this study show that the organic milk produced under the farming conditions practiced in Greece has higher nutritional value, due to its FA profile, compared with the respective conventional milk.

  11. Automated audiometry using apple iOS-based application technology.

    PubMed

    Foulad, Allen; Bui, Peggy; Djalilian, Hamid

    2013-11-01

    The aim of this study is to determine the feasibility of an Apple iOS-based automated hearing testing application and to compare its accuracy with conventional audiometry. Prospective diagnostic study. Setting Academic medical center. An iOS-based software application was developed to perform automated pure-tone hearing testing on the iPhone, iPod touch, and iPad. To assess for device variations and compatibility, preliminary work was performed to compare the standardized sound output (dB) of various Apple device and headset combinations. Forty-two subjects underwent automated iOS-based hearing testing in a sound booth, automated iOS-based hearing testing in a quiet room, and conventional manual audiometry. The maximum difference in sound intensity between various Apple device and headset combinations was 4 dB. On average, 96% (95% confidence interval [CI], 91%-100%) of the threshold values obtained using the automated test in a sound booth were within 10 dB of the corresponding threshold values obtained using conventional audiometry. When the automated test was performed in a quiet room, 94% (95% CI, 87%-100%) of the threshold values were within 10 dB of the threshold values obtained using conventional audiometry. Under standardized testing conditions, 90% of the subjects preferred iOS-based audiometry as opposed to conventional audiometry. Apple iOS-based devices provide a platform for automated air conduction audiometry without requiring extra equipment and yield hearing test results that approach those of conventional audiometry.

  12. TU-CD-207-05: A Novel Digital Tomosynthesis System Using Orthogonal Scanning Technique: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J; Park, C; Kauweloa, K

    2015-06-15

    Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-raymore » projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various on-line clinical applications.« less

  13. Unidirectional growth of benzil crystal from solution by Sankaranarayanan-Ramasamy method and its characterization

    NASA Astrophysics Data System (ADS)

    Rajalakshmi, M.; Shyju, T. S.; Indirajith, R.; Gopalakrishnan, R.

    2012-02-01

    Good quality <1 0 0> benzil single crystal with a diameter 18 mm and length 75 mm was successfully grown from solution by the unidirectional growth method of Sankaranarayanan-Ramasamy (SR) for the first time in the literature. The seed crystals have been harvested from conventional solution growth technique and subsequently used for unidirectional growth. The grown crystal was subjected to various characterization studies. The results of UV-vis spectral analysis, photoluminescence, etching and microhardness studies were compared with conventional solution grown crystal to that of SR method grown crystal. The quality of SR method grown benzil crystal is better than conventional solution grown crystal.

  14. Rationale for the tinnitus retraining therapy trial.

    PubMed

    Formby, Craig; Scherer, Roberta

    2013-01-01

    The Tinnitus Retraining Therapy Trial (TRTT) is a National Institutes of Health-sponsored, multi-centered, placebo-controlled, randomized trial evaluating the efficacy of tinnitus retraining therapy (TRT) and its component parts, directive counseling and sound therapy, as treatments for subjective debilitating tinnitus in the military. The TRTT will enroll 228 individuals at an allocation ratio of 1:1:1 to: (1) directive counseling and sound therapy using conventional sound generators; (2) directive counseling and placebo sound generators; or (3) standard of care as administered in the military. Study centers include a Study Chair's Office, a Data Coordinating Center, and six Military Clinical Centers with treatment and data collection standardized across all clinics. The primary outcome is change in Tinnitus Questionnaire (TQ) score assessed longitudinally at 3, 6, 12, and 18-month follow-up visits. Secondary outcomes include: Change in TQ sub-scales, Tinnitus Handicap Inventory, Tinnitus Functional Index, and TRT interview visual analog scale; audiometric and psychoacoustic measures; and change in quality of life. The TRTT will evaluate TRT efficacy by comparing TRT (directive counseling and conventional sound generators) with standard of care; directive counseling by comparing directive counseling plus placebo sound generators versus standard of care; and sound therapy by comparing conventional versus placebo sound generators. We hypothesize that full TRT will be more efficacious than standard of care, directive counseling and placebo sound generators more efficacious than standard of care, and conventional more efficacious than placebo sound generators in habituating the tinnitus awareness, annoyance, and impact on the study participant's life.

  15. Plaque reduction over time of an integrated oral hygiene system.

    PubMed

    Nunn, Martha E; Ruhlman, C Douglas; Mallatt, Philip R; Rodriguez, Sally M; Ortblad, Katherine M

    2004-10-01

    This article compares the efficacy of a prototype integrated system (the IntelliClean System from Sonicare and Crest) in the reduction of supragingival plaque to that of a manual toothbrush and conventional toothpaste. The integrated system was compared to a manual toothbrush with conventional toothpaste in a randomized, single-blinded, parallel, 4-week, controlled clinical trial with 100 subjects randomized to each treatment group. There was a low dropout rate, with 89 subjects in the manual toothbrush group (11% loss to follow-up) and 93 subjects in the integrated system group (7% loss to follow-up) completing the study. The Turesky modification of the Quigley and Hein Plaque Index was used to assess full-mouth plaque scores for each subject. Prebrushing plaque scores were obtained at baseline and at 4 weeks after 14 to 20 hours of plaque accumulation. A survey also was conducted at the conclusion of the study to determine the attitude toward the two oral hygiene systems. The integrated system was found to significantly reduce overall and interproximal prebrushing plaque scores over 4 weeks, both by 8.6%, demonstrating statistically significant superiority in overall plaque reduction (P = .002) and interproximal plaque reduction (P < .001) compared to the manual toothbrush with conventional toothpaste, which showed no significant reduction in either overall plaque or interproximal plaque. This study demonstrates that the IntelliClean System from Sonicare and Crest is superior to a manual toothbrush with conventional toothpaste in reducing overall plaque and interproximal plaque over time.

  16. Comparing errors in ED computer-assisted vs conventional pediatric drug dosing and administration.

    PubMed

    Yamamoto, Loren; Kanemori, Joan

    2010-06-01

    Compared to fixed-dose single-vial drug administration in adults, pediatric drug dosing and administration requires a series of calculations, all of which are potentially error prone. The purpose of this study is to compare error rates and task completion times for common pediatric medication scenarios using computer program assistance vs conventional methods. Two versions of a 4-part paper-based test were developed. Each part consisted of a set of medication administration and/or dosing tasks. Emergency department and pediatric intensive care unit nurse volunteers completed these tasks using both methods (sequence assigned to start with a conventional or a computer-assisted approach). Completion times, errors, and the reason for the error were recorded. Thirty-eight nurses completed the study. Summing the completion of all 4 parts, the mean conventional total time was 1243 seconds vs the mean computer program total time of 879 seconds (P < .001). The conventional manual method had a mean of 1.8 errors vs the computer program with a mean of 0.7 errors (P < .001). Of the 97 total errors, 36 were due to misreading the drug concentration on the label, 34 were due to calculation errors, and 8 were due to misplaced decimals. Of the 36 label interpretation errors, 18 (50%) occurred with digoxin or insulin. Computerized assistance reduced errors and the time required for drug administration calculations. A pattern of errors emerged, noting that reading/interpreting certain drug labels were more error prone. Optimizing the layout of drug labels could reduce the error rate for error-prone labels. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Intravoxel Incoherent Motion MR Imaging in the Differentiation of Benign and Malignant Sinonasal Lesions: Comparison with Conventional Diffusion-Weighted MR Imaging.

    PubMed

    Xiao, Z; Tang, Z; Qiang, J; Wang, S; Qian, W; Zhong, Y; Wang, R; Wang, J; Wu, L; Tang, W; Zhang, Z

    2018-01-25

    Intravoxel incoherent motion is a promising method for the differentiation of sinonasal lesions. This study aimed to evaluate the value of intravoxel incoherent motion in the differentiation of benign and malignant sinonasal lesions and to compare the diagnostic performance of intravoxel incoherent motion with that of conventional DWI. One hundred thirty-one patients with histologically proved solid sinonasal lesions (56 benign and 75 malignant) who underwent conventional DWI and intravoxel incoherent motion were recruited in this study. The diffusion coefficient ( D ), pseudodiffusion coefficient ( D *), and perfusion fraction ( f ) values derived from intravoxel incoherent motion and ADC values derived from conventional DWI were measured and compared between the 2 groups using the Student t test. Receiver operating characteristic curve analysis, logistic regression analysis, and 10-fold cross-validation were performed to evaluate the diagnostic performance of single-parametric and multiparametric models. The mean ADC and D values were significantly lower in malignant sinonasal lesions than in benign sinonasal lesions (both P < .001). The mean f value was higher in malignant lesions than in benign lesions ( P = .003). Multiparametric models can significantly improve the cross-validated areas under the curve for the differentiation of sinonasal lesions compared with single-parametric models (all corrected P < .05 except the D value). The model of D + f provided a better diagnostic performance than the ADC value (corrected P < .001). Intravoxel incoherent motion appears to be a more effective MR imaging technique than conventional DWI in the differentiation of benign and malignant sinonasal lesions. © 2018 by American Journal of Neuroradiology.

  18. Quality of life after robotic thyroidectomy by a gasless unilateral axillary approach.

    PubMed

    Song, Chang Myeon; Ji, Yong Bae; Bang, Hyang Sook; Park, Chul Won; Kim, Dong Sun; Tae, Kyung

    2014-12-01

    Robotic thyroidectomies have been safely performed with early surgical outcomes comparable to conventional cervical thyroidectomies. However, health-related quality of life (HRQOL) after robotic thyroidectomy has not yet been evaluated. The aim of this study was to compare HRQOL of patients who underwent robotic thyroidectomy with that of those who received conventional thyroidectomy. We conducted a cross-sectional study in 111 patients who underwent either robotic thyroidectomy (44 patients) via a gasless unilateral axillary approach, or conventional cervical thyroidectomy (67 patients), for papillary thyroid carcinoma (PTC). HRQOL of patients was assessed using two questionnaires, the University of Washington Quality of Life (UW-QOL) questionnaire for patients with head and neck cancer, and the Quality of Life-Thyroid Version (QOL-TV), which was specifically designed for thyroid cancer patients. The survey using the questionnaires was performed 1 year after surgery at a routine outpatient clinic follow-up. There was no difference in UW-QOL scores between the two groups for any factor other than neck appearance and physical composite score, which were higher in the robotic group. Humor (mood) and anxiety, emotional measures of UW-QOL, were selected by patients in both groups as being their most significant issue during the preceding 7 days. There was no between-group difference in the four QOL-TV domains (physical, psychological, social, and spiritual well-being). Patients who underwent robotic thyroidectomy reported a higher score for satisfaction with neck appearance compared to patients receiving conventional cervical thyroidectomy. However, the overall HRQOL of patients in the robotic and conventional groups was similar.

  19. Holographic neural networks versus conventional neural networks: a comparative evaluation for the classification of landmine targets in ground-penetrating radar images

    NASA Astrophysics Data System (ADS)

    Mudigonda, Naga R.; Kacelenga, Ray; Edwards, Mark

    2004-09-01

    This paper evaluates the performance of a holographic neural network in comparison with a conventional feedforward backpropagation neural network for the classification of landmine targets in ground penetrating radar images. The data used in the study was acquired from four different test sites using the landmine detection system developed by General Dynamics Canada Ltd., in collaboration with the Defense Research and Development Canada, Suffield. A set of seven features extracted for each detected alarm is used as stimulus inputs for the networks. The recall responses of the networks are then evaluated against the ground truth to declare true or false detections. The area computed under the receiver operating characteristic curve is used for comparative purposes. With a large dataset comprising of data from multiple sites, both the holographic and conventional networks showed comparable trends in recall accuracies with area values of 0.88 and 0.87, respectively. By using independent validation datasets, the holographic network"s generalization performance was observed to be better (mean area = 0.86) as compared to the conventional network (mean area = 0.82). Despite the widely publicized theoretical advantages of the holographic technology, use of more than the required number of cortical memory elements resulted in an over-fitting phenomenon of the holographic network.

  20. Liposomal Bupivacaine Injection Technique in Total Knee Arthroplasty.

    PubMed

    Meneghini, R Michael; Bagsby, Deren; Ireland, Philip H; Ziemba-Davis, Mary; Lovro, Luke R

    2017-01-01

    Liposomal bupivacaine has gained popularity for pain control after total knee arthroplasty (TKA), yet its true efficacy remains unproven. We compared the efficacy of two different periarticular injection (PAI) techniques for liposomal bupivacaine with a conventional PAI control group. This retrospective cohort study compared consecutive patients undergoing TKA with a manufacturer-recommended, optimized injection technique for liposomal bupivacaine, a traditional injection technique for liposomal bupivacaine, and a conventional PAI of ropivacaine, morphine, and epinephrine. The optimized technique utilized a smaller gauge needle and more injection sites. Self-reported pain scores, rescue opioids, and side effects were compared. There were 41 patients in the liposomal bupivacaine optimized injection group, 60 in the liposomal bupivacaine traditional injection group, and 184 in the conventional PAI control group. PAI liposomal bupivacaine delivered via manufacturer-recommended technique offered no benefit over PAI ropivacaine, morphine, and epinephrine. Mean pain scores and the proportions reporting no or mild pain, time to first opioid, and amount of opioids consumed were not better with PAI liposomal bupivacaine compared with PAI ropivacaine, morphine, and epinephrine. The use of the manufacturer-recommended technique for PAI of liposomal bupivacaine does not offer benefit over a conventional, less expensive PAI during TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Accuracy of reading liquid based cytology slides using the ThinPrep Imager compared with conventional cytology: prospective study

    PubMed Central

    d'Assuncao, Jefferson; Irwig, Les; Macaskill, Petra; Chan, Siew F; Richards, Adele; Farnsworth, Annabelle

    2007-01-01

    Objective To compare the accuracy of liquid based cytology using the computerised ThinPrep Imager with that of manually read conventional cytology. Design Prospective study. Setting Pathology laboratory in Sydney, Australia. Participants 55 164 split sample pairs (liquid based sample collected after conventional sample from one collection) from consecutive samples of women choosing both types of cytology and whose specimens were examined between August 2004 and June 2005. Main outcome measures Primary outcome was accuracy of slides for detecting squamous lesions. Secondary outcomes were rate of unsatisfactory slides, distribution of squamous cytological classifications, and accuracy of detecting glandular lesions. Results Fewer unsatisfactory slides were found for imager read cytology than for conventional cytology (1.8% v 3.1%; P<0.001). More slides were classified as abnormal by imager read cytology (7.4% v 6.0% overall and 2.8% v 2.2% for cervical intraepithelial neoplasia of grade 1 or higher). Among 550 patients in whom imager read cytology was cervical intraepithelial neoplasia grade 1 or higher and conventional cytology was less severe than grade 1, 133 of 380 biopsy samples taken were high grade histology. Among 294 patients in whom imager read cytology was less severe than cervical intraepithelial neoplasia grade 1 and conventional cytology was grade 1 or higher, 62 of 210 biopsy samples taken were high grade histology. Imager read cytology therefore detected 71 more cases of high grade histology than did conventional cytology, resulting from 170 more biopsies. Similar results were found when one pathologist reread the slides, masked to cytology results. Conclusion The ThinPrep Imager detects 1.29 more cases of histological high grade squamous disease per 1000 women screened than conventional cytology, with cervical intraepithelial neoplasia grade 1 as the threshold for referral to colposcopy. More imager read slides than conventional slides were satisfactory for examination and more contained low grade cytological abnormalities. PMID:17604301

  2. The Value of Diffusion-Weighted Imaging in Combination With Conventional Magnetic Resonance Imaging for Improving Tumor Detection for Early Cervical Carcinoma Treated With Fertility-Sparing Surgery.

    PubMed

    Li, Xiulei; Wang, Ling; Li, Yong; Song, Peiji

    2017-10-01

    This study aimed to investigate the value of diffusion-weighted imaging (DWI) in combination with conventional magnetic resonance imaging (MRI) for improving tumor detection in young patients treated with fertility-sparing surgery because of early cervical carcinoma. Fifty-four patients with stage Ia or Ib1 cervical carcinoma were enrolled into this study. Magnetic resonance examinations were performed for these patients using conventional MRI (including T1-weighted imaging, T2-weighted imaging, and dynamic contrast-enhanced MRI) and DWI. The apparent diffusion coefficient (ADC) values of cervical carcinoma were analyzed quantitatively and compared with that of adjacent epithelium. Sensitivity, positive predictive value, and accuracy of 2 sets of MRI sequences were calculated on the basis of histologic results, and the diagnostic ability of conventional MRI/DWI combinations was compared with that of conventional MRI. The mean ADC value from cervical carcinoma (mean, 786 × 10 mm/s ± 100) was significantly lower than that from adjacent epithelium (mean, 1352 × 10 mm/s ± 147) (P = 0.01). When the threshold ADC value set as 1010 × 10 mm/s, the sensitivity and specificity for differentiating cervical carcinoma from nontumor epithelium were 78.2% and 67.2%, respectively. The sensitivity and accuracy of conventional MRI for tumor detection were 76.0% and 70.4%, whereas the sensitivity and accuracy of conventional MRI/DWI combinations were 91.7% and 90.7%, respectively. Conventional MRI/DWI combinations revealed a positive predictive value of 97.8% and only 4 false-negative findings. The addition of DWI to conventional MRI considerably improves the sensitivity and accuracy of tumor detection in young patients treated with fertility-sparing surgery, which supports the inclusion quantitative analysis of ADC value in routine MRI protocol before fertility-sparing surgery.

  3. Chemical and toxicological characteristics of conventional and low-TSNA moist snuff tobacco products.

    PubMed

    Song, Min-Ae; Marian, Catalin; Brasky, Theodore M; Reisinger, Sarah; Djordjevic, Mirjana; Shields, Peter G

    2016-03-14

    Use of smokeless tobacco products (STPs) is associated with oral cavity cancer and other health risks. Comprehensive analysis for chemical composition and toxicity is needed to compare conventional and newer STPs with lower tobacco-specific nitrosamines (TSNAs) yields. Seven conventional and 12 low-TSNA moist snuff products purchased in the U.S., Sweden, and South Africa were analyzed for 18 chemical constituents (International Agency for Research on Cancer classified carcinogens), pH, nicotine, and free nicotine. Chemicals were compared in each product using Wilcoxon rank-sum test and principle component analysis (PCA). Conventional compared to low-TSNA moist snuff products had higher ammonia, benzo[a]pyrene, cadmium, nickel, nicotine, nitrate, and TSNAs and had lower arsenic in dry weight content and per mg nicotine. Lead and chromium were significantly higher in low-TSNA moist snuff products. PCA showed a clear difference for constituents between conventional and low-TSNA moist snuff products. Differences among products were reduced when considered on a per mg nicotine basis. As one way to contextualize differences in constituent levels, probabilistic lifetime cancer risk was estimated for chemicals included in The University of California's carcinogenic potency database (CPDB). Estimated probabilistic cancer risks were 3.77-fold or 3-fold higher in conventional compared to low-TSNA moist snuff products under dry weight or under per mg nicotine content, respectively. In vitro testing for the STPs indicated low level toxicity and no substantial differences. The comprehensive chemical characterization of both conventional and low-TSNA moist snuff products from this study provides a broader assessment of understanding differences in carcinogenic potential of the products. In addition, the high levels and probabilistic cancer risk estimates for certain chemical constituents of smokeless tobacco products will further inform regulatory decision makers and aid them in their efforts to reduce carcinogen exposure in smokeless tobacco products. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Robotic therapy provides a stimulus for upper limb motor recovery after stroke that is complementary to and distinct from conventional therapy.

    PubMed

    Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J; Lum, Peter S

    2014-05-01

    Individuals with chronic stroke often have long-lasting upper extremity impairments that impede function during activities of daily living. Rehabilitation robotics have shown promise in improving arm function, but current systems do not allow realistic training of activities of daily living. We have incorporated the ARMin III and HandSOME device into a novel robotic therapy modality that provides functional training of reach and grasp tasks. To compare the effects of equal doses of robotic and conventional therapy in individuals with chronic stroke. Subjects were randomized to 12 hours of robotic or conventional therapy and then crossed over to the other therapy type after a 1-month washout period. Twelve moderate to severely impaired individuals with chronic stroke were enrolled, and 10 completed the study. Across the 3-month study period, subjects showed significant improvements in the Fugl-Meyer (P = .013) and Box and Blocks tests (P = .028). The robotic intervention produced significantly greater improvements in the Action Research Arm Test than conventional therapy (P = .033). Gains in the Box and Blocks test from conventional therapy were larger than from robotic therapy in subjects who received conventional therapy after robotic therapy (P = .044). Data suggest that robotic therapy can elicit improvements in arm function that are distinct from conventional therapy and supplements conventional methods to improve outcomes. Results from this pilot study should be confirmed in a larger study.

  5. Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy

    PubMed Central

    Singh, Sunint; Palaskar, Jayant N.; Mittal, Sanjeev

    2013-01-01

    Background: Conventional heat cure poly methyl methacrylate (PMMA) is the most commonly used denture base resin despite having some short comings. Lengthy polymerization time being one of them and in order to overcome this fact microwave curing method was recommended. Unavailability of specially designed microwavable acrylic resin made it unpopular. Therefore, in this study, conventional heat cure PMMA was polymerized by microwave energy. Aim and Objectives: This study was designed to evaluate the surface porosities in PMMA cured by conventional water bath and microwave energy and compare it with microwavable acrylic resin cured by microwave energy. Materials and Methods: Wax samples were obtained by pouring molten wax into a metal mold of 25 mm × 12 mm × 3 mm dimensions. These samples were divided into three groups namely C, CM, and M. Group C denotes conventional heat cure PMMA cured by water bath method, CM denotes conventional heat cure PMMA cured by microwave energy, M denotes specially designed microwavable acrylic denture base resin cured by microwave energy. After polymerization, each sample was scanned in three pre-marked areas for surface porosities using the optical microscope. As per the literature available, this instrument is being used for the first time to measure the porosity in acrylic resin. It is a reliable method of measuring area of surface pores. Portion of the sample being scanned is displayed on the computer and with the help of software area of each pore was measured and data were analyzed. Results: Conventional heat cure PMMA samples cured by microwave energy showed maximum porosities than the samples cured by conventional water bath method and microwavable acrylic resin cured by microwave energy. Higher percentage of porosities was statistically significant, but well within the range to be clinically acceptable. Conclusion: Within the limitations of this in-vitro study, conventional heat cure PMMA can be cured by microwave energy without compromising on its property such as surface porosity. PMID:24015000

  6. A comparison between conventional and LANDSAT based hydrologic modeling: The Four Mile Run case study

    NASA Technical Reports Server (NTRS)

    Ragan, R. M.; Jackson, T. J.; Fitch, W. N.; Shubinski, R. P.

    1976-01-01

    Models designed to support the hydrologic studies associated with urban water resources planning require input parameters that are defined in terms of land cover. Estimating the land cover is a difficult and expensive task when drainage areas larger than a few sq. km are involved. Conventional and LANDSAT based methods for estimating the land cover based input parameters required by hydrologic planning models were compared in a case study of the 50.5 sq. km (19.5 sq. mi) Four Mile Run Watershed in Virginia. Results of the study indicate that the LANDSAT based approach is highly cost effective for planning model studies. The conventional approach to define inputs was based on 1:3600 aerial photos, required 110 man-days and a total cost of $14,000. The LANDSAT based approach required 6.9 man-days and cost $2,350. The conventional and LANDSAT based models gave similar results relative to discharges and estimated annual damages expected from no flood control, channelization, and detention storage alternatives.

  7. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

    PubMed Central

    Al-mejrad, Lamya A.; Albarrag, Ahmed M.

    2017-01-01

    PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649

  8. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    PubMed

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  9. Application of mid-frequency ventilation in an animal model of lung injury: a pilot study.

    PubMed

    Mireles-Cabodevila, Eduardo; Chatburn, Robert L; Thurman, Tracy L; Zabala, Luis M; Holt, Shirley J; Swearingen, Christopher J; Heulitt, Mark J

    2014-11-01

    Mid-frequency ventilation (MFV) is a mode of pressure control ventilation based on an optimal targeting scheme that maximizes alveolar ventilation and minimizes tidal volume (VT). This study was designed to compare the effects of conventional mechanical ventilation using a lung-protective strategy with MFV in a porcine model of lung injury. Our hypothesis was that MFV can maximize ventilation at higher frequencies without adverse consequences. We compared ventilation and hemodynamic outcomes between conventional ventilation and MFV. This was a prospective study of 6 live Yorkshire pigs (10 ± 0.5 kg). The animals were subjected to lung injury induced by saline lavage and injurious conventional mechanical ventilation. Baseline conventional pressure control continuous mandatory ventilation was applied with V(T) = 6 mL/kg and PEEP determined using a decremental PEEP trial. A manual decision support algorithm was used to implement MFV using the same conventional ventilator. We measured P(aCO2), P(aO2), end-tidal carbon dioxide, cardiac output, arterial and venous blood oxygen saturation, pulmonary and systemic vascular pressures, and lactic acid. The MFV algorithm produced the same minute ventilation as conventional ventilation but with lower V(T) (-1 ± 0.7 mL/kg) and higher frequency (32.1 ± 6.8 vs 55.7 ± 15.8 breaths/min, P < .002). There were no differences between conventional ventilation and MFV for mean airway pressures (16.1 ± 1.3 vs 16.4 ± 2 cm H2O, P = .75) even when auto-PEEP was higher (0.6 ± 0.9 vs 2.4 ± 1.1 cm H2O, P = .02). There were no significant differences in any hemodynamic measurements, although heart rate was higher during MFV. In this pilot study, we demonstrate that MFV allows the use of higher breathing frequencies and lower V(T) than conventional ventilation to maximize alveolar ventilation. We describe the ventilatory or hemodynamic effects of MFV. We also demonstrate that the application of a decision support algorithm to manage MFV is feasible. Copyright © 2014 by Daedalus Enterprises.

  10. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.

    PubMed

    Shepherd, Emma; Stuart, Graham; Martin, Rob; Walsh, Mark A

    2015-06-01

    SelectSecure™ pacing leads (Medtronic Inc) are increasingly being used in pediatric patients and adults with structural congenital heart disease. The 4Fr lead is ideal for patients who may require lifelong pacing and can be advantageous for patients with complex anatomy. The purpose of this study was to compare the extraction of SelectSecure leads with conventional (stylette-driven) pacing leads in patients with structural congenital heart disease and congenital atrioventricular block. The data on lead extractions from pediatric and adult congenital heart disease (ACHD) patients from August 2004 to July 2014 at Bristol Royal Hospital for Children and the Bristol Heart Institute were reviewed. Multivariable regression analysis was used to determine whether conventional pacing leads were associated with a more difficult extraction process. A total of 57 patients underwent pacemaker lead extractions (22 SelectSecure, 35 conventional). No deaths occurred. Mean age at the time of extraction was 17.6 ± 10.5 years, mean weight was 47 ± 18 kg, and mean lead age was 5.6 ± 2.6 years (range 1-11 years). Complex extraction (partial extraction/femoral extraction) was more common in patients with conventional pacing leads at univariate (P < .01) and multivariate (P = .04) levels. Lead age was also a significant predictor of complex extraction (P < .01). SelectSecure leads can be successfully extracted using techniques that are used for conventional pacing leads. They are less likely to be partially extracted and are less likely to require extraction using a femoral approach compared with conventional pacing leads. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Accelerated versus conventional corneal collagen cross-linking in patients with keratoconus: an intrapatient comparative study.

    PubMed

    Sadoughi, Mohammad Mehdi; Einollahi, Bahram; Baradaran-Rafii, Alireza; Roshandel, Danial; Hasani, Hamidreza; Nazeri, Mehrdad

    2018-02-01

    To compare the outcomes of the conventional and accelerated corneal collagen cross-linking (CXL) in patients with bilateral progressive keratoconus (KC). Fifteen consecutive patients with bilateral progressive KC were enrolled. In each patient, the fellow eyes were randomly assigned to the conventional CXL (3 mW/cm 2 for 30 min) or accelerated CXL (ACXL) (9 mW/cm 2 for 10 min) groups. Manifest refraction; uncorrected and corrected distant visual acuity; maximum and mean keratometry; corneal hysteresis and corneal resistance factor; endothelial cell density and morphology; central corneal thickness; and wavefront aberrations were measured before and 12 months after the CXL. Manifest refraction spherical equivalent and refractive cylinder improved significantly only in conventional group. Uncorrected and corrected distant visual acuity did not change significantly in either group. Also there was no significant change in the maximum and mean keratometry after 12 months. There was significant decrease in central corneal thickness in both groups which was more prominent in conventional group. Endothelial cell density reduced only in the conventional group which was not statistically significant (P = 0.147). CH, CRF, and wavefront aberrations did not change significantly in either group. We did not observe any significant difference in the changes of the variables between the two groups. Accelerated CXL with 9 mW/cm 2 irradiation for 10 min had similar refractive, visual, keratometric, and aberrometric results and less adverse effects on the corneal thickness and endothelial cells as compared with the conventional method after 12 months follow-up. However, randomized clinical trials with longer follow-ups and larger sample sizes are needed.

  12. Dose reduction of up to 89% while maintaining image quality in cardiovascular CT achieved with prospective ECG gating

    NASA Astrophysics Data System (ADS)

    Londt, John H.; Shreter, Uri; Vass, Melissa; Hsieh, Jiang; Ge, Zhanyu; Adda, Olivier; Dowe, David A.; Sabllayrolles, Jean-Louis

    2007-03-01

    We present the results of dose and image quality performance evaluation of a novel, prospective ECG-gated Coronary CT Angiography acquisition mode (SnapShot Pulse, LightSpeed VCT-XT scanner, GE Healthcare, Waukesha, WI), and compare it to conventional retrospective ECG gated helical acquisition in clinical and phantom studies. Image quality phantoms were used to measure noise, slice sensitivity profile, in-plane resolution, low contrast detectability and dose, using the two acquisition modes. Clinical image quality and diagnostic confidence were evaluated in a study of 31 patients scanned with the two acquisition modes. Radiation dose reduction in clinical practice was evaluated by tracking 120 consecutive patients scanned with the prospectively gated scan mode. In the phantom measurements, the prospectively gated mode resulted in equivalent or better image quality measures at dose reductions of up to 89% compared to non-ECG modulated conventional helical scans. In the clinical study, image quality was rated excellent by expert radiologist reviewing the cases, with pathology being identical using the two acquisition modes. The average dose to patients in the clinical practice study was 5.6 mSv, representing 50% reduction compared to a similar patient population scanned with the conventional helical mode.

  13. Atraumatic restorative treatment versus conventional restorative treatment for managing dental caries.

    PubMed

    Dorri, Mojtaba; Martinez-Zapata, Maria José; Walsh, Tanya; Marinho, Valeria Cc; Sheiham Deceased, Aubrey; Zaror, Carlos

    2017-12-28

    Dental caries is a sugar-dependent disease that damages tooth structure and, due to loss of mineral components, may eventually lead to cavitation. Dental caries is the most prevalent disease worldwide and is considered the most important burden of oral health. Conventional treatment methods (drill and fill) involve the use of rotary burs under local anaesthesia. The need for an electricity supply, expensive handpieces and highly trained dental health personnel may limit access to dental treatment, especially in underdeveloped regions.To overcome the limitations of conventional restorative treatment, the Atraumatic Restorative Treatment (ART) was developed, mainly for treating caries in children living in under-served areas of the world where resources and facilities such as electricity and trained manpower are limited. ART is a minimally invasive approach which involves removal of decayed tissue using hand instruments alone, usually without use of anaesthesia and electrically driven equipment, and restoration of the dental cavity with an adhesive material (glass ionomer cement (GIC), composite resins, resin-modified glass-ionomer cement (RM-GICs) and compomers). To assess the effects of Atraumatic Restorative Treatment (ART) compared with conventional treatment for managing dental caries lesions in the primary and permanent teeth of children and adults. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 February 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 1), MEDLINE Ovid (1946 to 22 February 2017), Embase Ovid (1980 to 22 February 2017), LILACS BIREME Virtual Health Library (Latin American and Caribbean Health Science Information database; 1982 to 22 February 2017) and BBO BIREME Virtual Health Library (Bibliografia Brasileira de Odontologia; 1986 to 22 February 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. We included randomised controlled trials (RCTs) with at least six months' follow-up that compared the effects of ART with a conventional restorative approach using the same or different restorative dental materials to treat caries lesions. Two review authors independently screened search results, extracted data from included studies and assessed the risk of bias in those studies. We used standard methodological procedures expected by Cochrane to evaluate risk of bias and synthesise data. Where pooling was appropriate we conducted meta-analyses using the random-effects model. We assessed the quality of the evidence using GRADE criteria. We included a total of 15 eligible studies randomising 3760 participants in this review. The age of participants across the studies ranged from 3 to 101 years, with a mean of 25.42 years. 48% of participants were male. All included studies were published between 2002 and 2016. Two of the 15 studies declared that the financial support was from companies that manufacture restorative material. Five studies were individually randomised parallel-group studies; six were cluster-randomised parallel-group studies; and four were randomised studies that used a split-mouth design. Eleven studies evaluated the effects of ART on primary teeth only, and four on permanent teeth. The follow-up period of the included studies ranged from 6 months to 36 months. We judged all studies to be at high risk of bias.For the main comparison of ART compared to conventional treatment using the same material: all but two studies used high-viscosity glass ionomer (H-GIC) as the restorative material; one study used a composite material; and one study used resin-modified glass ionomer cement (RM-GIC)).Compared to conventional treatment using H-GIC, ART may increase the risk of restoration failure in the primary dentition, over a follow-up period from 12 to 24 months (OR 1.60, 95% CI 1.13 to 2.27, five studies; 643 participants analysed; low-quality evidence). Our confidence in this effect estimate is limited due to serious concerns over risk of performance and attrition bias. For this comparison, ART may reduce pain during procedure compared with conventional treatment (MD -0.65, 95% CI -1.38 to 0.07; 40 participants analysed; low-quality evidence)Comparisons of ART to conventional treatment using composite or RM-GIC were downgraded to very low quality due to indirectness, imprecision and high risk of performance and attrition bias. Given the very low quality of the evidence from single studies, we are uncertain about the restoration failure of ART compared with conventional treatment using composite over a 24-month follow-up period (OR 1.11, 95% CI 0.54 to 2.29; one study; 57 participants) and ART using RM-GIC in the permanent teeth of older adults with root caries lesions over a six-month follow-up period (OR 2.71, 95% CI 0.94 to 7.81; one study; 64 participants).No studies reported on adverse events or costs. Low-quality evidence suggests that ART using H-GIC may have a higher risk of restoration failure than conventional treatment for caries lesions in primary teeth. The effects of ART using composite and RM-GIC are uncertain due to the very low quality of the evidence and we cannot rely on the findings. Most studies evaluated the effects of ART on the primary dentition.Well-designed RCTs are required that report on restoration failure at clinically meaningful time points, as well as participant-reported outcomes such as pain and discomfort. Due to the potential confounding effects from the use of different dental materials, a robust body of evidence on the effects of ART compared with conventional treatment using the same restoration material is necessary. We identified four ongoing trials that could provide further insights into this area.

  14. Cryotop vitrification as compared to conventional slow freezing for human embryos at the cleavage stage: survival and outcomes.

    PubMed

    Lin, Tseng-Kai; Su, Jin-Tsung; Lee, Fa-Kung; Lin, Yu-Ru; Lo, Hsiao-Ching

    2010-09-01

    This study was conducted to compare the efficacy of cryotop vitrification of human cleavage-stage embryos to that of conventional slow freezing of these embryos with respect to survival. A second objective was to compare the two cryopreservation techniques with respect to outcomes for a cohort of women. Cleavage-stage embryos from 102 patients were cryopreserved either by vitrification (57 patients) or by traditional slow freezing (45 patients). After thawing, rates of embryo survival, implantation, and clinical pregnancy were determined. Survival of embryos was significantly higher with the vitrification procedure as compared to traditional slow freezing [287/298 (96.3%) vs. 294/446 (65.9%); p < 0.05). Rates of implantation and clinical pregnancy were also significantly higher using vitrification procedure as compared to the slow freezing procedure (24.3% vs. 7.1% and 35.6% vs. 15.6% respectively, p < 0.05). As compared to conventional slow freezing, cryopreservation of human cleavage-stage embryo using vitrification results in higher rates of embryo survival, implantation, and clinical pregnancy. Vitrification therefore represents the superior cryopreservation technique for cleavage-stage embryos. Copyright © 2010 Taiwan Association of Obstetric & Gynecology. Published by Elsevier B.V. All rights reserved.

  15. A matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy.

    PubMed

    Ellison, Jonathan S; Montgomery, Jeffrey S; Wolf, J Stuart; Hafez, Khaled S; Miller, David C; Weizer, Alon Z

    2012-07-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot-assisted partial nephrectomy likely improves surgeon and patient accessibility to minimally invasive nephron sparing surgery. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Commentary on "a matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy." Ellison JS, Montgomery JS, Wolf Jr JS, Hafez KS, Miller DC, Weizer AZ, Department of Urology, University of Michigan, Ann Arbor, MI, USA: J Urol 2012;188(1):45-50.

    PubMed

    Kane, Christopher

    2013-02-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot-assisted partial nephrectomy likely improves surgeon and patient accessibility to minimally invasive nephron sparing surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Accuracy of pedicle screw insertion in the thoracic and lumbar spine: a comparative study between percutaneous screw insertion and conventional open technique.

    PubMed

    Ikeuchi, Hiroko; Ikuta, Ko

    2016-09-01

    In the last decade, posterior instrumented fusion using percutaneous pedicle screws (PPSs) had been growing in popularity, and its safety and good clinical results have been reported. However, there have been few previous reports of the accuracy of PPS placement compared with that of conventional open screw insertion in an institution. This study aimed to evaluate the accuracy of PPS placement compared with that of conventional open technique. One hundred patients were treated with posterior instrumented fusion of the thoracic and lumbar spine from April 2008 to July 2013. Four cases of revised instrumentation surgery were excluded. In this study, the pedicle screws inserted below Th7 were investigated, therefore, a total of 455 screws were enrolled. Two hundred and ninety-three pedicle screws were conventional open-inserted screws (O-group) and 162 screws were PPSs (P-group). We conducted a comparative study about the accuracy of placement between the two groups. Postoperative computed tomography scans were carried out to all patients, and the pedicle screw position was assessed according to a scoring system described by Zdichavsky et al. (Eur J Trauma 30:241-247, 2004; Eur J Trauma 30:234-240, 2004) and a classification described by Wiesner et al. (Spine 24:1599-1603, 1999). Based on Zdichavsky's scoring system, the number of grade Ia screws was 283 (96.6 %) in the O-group and 153 (94.4 %) in the P-group, whereas 5 screws (1.7 %) in the O-group and one screw (0.6 %) in the P-group were grade IIIa/IIIb. Meanwhile, the pedicle wall penetrations based on Wiesner classification were demonstrated in 20 screws (6.8 %) in the O-group, and 12 screws (7.4 %) in the P-group. No neurologic complications were observed and no screws had to be replaced in both groups. The PPSs could be ideally inserted without complications. There were no statistically significant differences about the accuracy between the conventional open insertion and PPS placement.

  18. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    PubMed

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p < 0.0001), and the correlation between IQ-SPECT with and without SCAC was also good (r = 0.907 and p < 0.0001). Regarding diagnostic performance, the sensitivity, specificity, and accuracy were 80.8, 78.9, and 79.4%, respectively, for the conventional SPECT; 80.8, 80.3, and 82.0%, respectively, for IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT was comparable with that of the conventional system regardless of different characteristics of myocardial accumulation in the conventional system.

  19. Three-year postoperative outcomes between MIS and conventional TLIF in1-segment lumbar disc herniation.

    PubMed

    Lv, You; Chen, Jingyang; Chen, Jinchuan; Wu, Yuling; Chen, Xiangyang; Liu, Yi; Chu, Zhaoming; Sheng, Luxin; Qin, Rujie; Chen, Ming

    2017-06-01

    The aim of this study is to assess the long-term clinical and radiological outcomes between minimally invasive (MIS) and conventional transforaminal lumbar interbody fusion (TLIF) in treating one-segment lumbar disc herniation (LDH). One-hundred and six patients treated by MIS-TLIF (50 cases) or conventional TLIF (56 cases) were included. Perioperative results were evaluated. Clinical outcomes were compared preoperatively and postoperatively. Radiologic parameters were based on a comparison of preoperative and three-year postoperative lumbar lordosis, segmental lordosis, sacral slope, the cross-sectional area of the paraspinal muscle and fusion rates. MIS TILF had significantly less blood, shorter operation time, mean return to work time and lower intramuscular pressure compared with the conventional group during the operation. VAS scores for lower back pain and ODI in MIS-TLIF were significantly decreased. The mean cross-sectional area of the paraspinal muscle was significantly decreased after surgery in the conventional TLIF group and no significant intragroup differences were established in the MIS-TLIF group. No significant differences were found in fusion rate, lumbar lordosis, segmental lordosis and sacral slope. Both MIS and conventional TLIF were beneficial for patients with LDH. However, MIS-TLIF manifests a great improvement in perioperative outcomes, low back pain, disability and preventing paraspinal muscle atrophy during the follow-up period observation.

  20. Comparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting

    PubMed Central

    Minion, Jessica; Pai, Madhukar; Ramsay, Andrew; Menzies, Dick; Greenaway, Christina

    2011-01-01

    Introduction Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. Methods In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. Results There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. Conclusions Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used. PMID:21811622

  1. Effects of persistent insecticides on beneficial soil arthropod in conventional fields compared to organic fields, puducherry.

    PubMed

    Anbarashan, Padmavathy; Gopalswamy, Poyyamoli

    2013-07-15

    The usage of synthetic fertilizers/insecticides in conventional farming has dramatically increased over the past decades. The aim of the study was to compare the effects of bio-pesticides and insecticides/pesticides on selected beneficial non targeted arthropods. Orders Collembola, Arachinida/Opiliones, Oribatida and Coleoptera were the main groups of arthropods found in the organic fields and Coleoptera, Oribatida, Gamasida and Collembola in conventional fields. Pesticides/insecticides had a significant effect on non-targeted arthropods order- Collembola, Arachinida/Opiliones, Hymenoptera and Thysonoptera were suppressed after pesticides/insecticides spraying. Bio-insecticides in organic fields had a non-significant effect on non targeted species and they started to increase in abundance after 7 days of spraying, whereas insecticide treatment in conventional fields had a significant long-term effect on non targeted arthropods and short term effect on pests/insects, it started to increase after 21 days of the spraying. These results indicate that insecticide treatment kept non targeted arthropods at low abundance. In conclusion, organic farming does not significantly affected the beneficial-non targeted arthropods biodiversity, whereas preventive insecticide application in conventional fields had significant negative effects on beneficial non targeted arthropods. Therefore, conventional farmers should restrict insecticide applications, unless pest densities reach the thresholds and more desirably can switch to organic farming practices.

  2. A comparison of the clinical effectiveness of spinal orthoses manufactured using the conventional manual method and CAD/CAM method in the management of AIS.

    PubMed

    Wong, M S; Cheng, C Y; Ng, B K W; Lam, T P; Chiu, S W

    2006-01-01

    Spinal orthoses are commonly prescribed to patients with moderate AIS for prevention of further deterioration. In a conventional manufacturing method, plaster bandages are used to get patient's body contour and plaster cast is rectified manually. With the introduction of CAD/CAM system, a series of automated processes from body scanning to digital rectification and milling of positive model can be performed in a fast and accurate fashion. This project is to study the impact of CAD/CAM method as compared with the conventional method. In assessing the 147 recruited subjects fitted with spinal orthoses (43 subjects using conventional method and 104 subjects using CAD/CAM method), significant decreases (p<0.05) were found in the Cobb angles when comparing the pre-intervention data with that of the first year of intervention. Regarding the learning curve, Orthotists are getting more competent with the CAD/CAM technique in four years time. The mean productivity of the CAD/CAM method is 2.75 times higher than that of the conventional method. The CAD/CAM method could achieve similar clinical outcomes and with its high efficiency, could be considered as substitute for conventional methods in fabricating spinal orthoses for patients with AIS.

  3. Are minimally invasive procedures harder to acquire than conventional surgical procedures?

    PubMed

    Hiemstra, Ellen; Kolkman, Wendela; le Cessie, Saskia; Jansen, Frank Willem

    2011-01-01

    It is frequently suggested that minimally invasive surgery (MIS) is harder to acquire than conventional surgery. To test this hypothesis, residents' learning curves of both surgical skills are compared. Residents had to be assessed using a general global rating scale of the OSATS (Objective Structured Assessment of Technical Skills) for every procedure they performed as primary surgeon during a 3-month clinical rotation in gynecological surgery. Nine postgraduate-year-4 residents collected a total of 319 OSATS during the 2 years and 3 months investigation period. These assessments concerned 129 MIS (laparoscopic and hysteroscopic) and 190 conventional (open abdominal and vaginal) procedures. Learning curves (in this study defined as OSATS score plotted against procedure-specific caseload) for MIS and conventional surgery were compared using a linear mixed model. The MIS curve revealed to be steeper than the conventional curve (1.77 vs. 0.75 OSATS points per assessed procedure; 95% CI 1.19-2.35 vs. 0.15-1.35, p < 0.01). Basic MIS procedures do not seem harder to acquire during residency than conventional surgical procedures. This may have resulted from the incorporation of structured MIS training programs in residency. Hopefully, this will lead to a more successful implementation of the advanced MIS procedures. Copyright © 2010 S. Karger AG, Basel.

  4. Retrospective study of efficacy of intravesical BCG alone in treatment of superficial bladder cancer.

    PubMed

    Mydlo, J H; Usher, S M; Camacho, F; Freed, S

    1986-09-01

    This is a review of 100 patients at our institution who were treated for superficial bladder cancer. In those patients with carcinoma in situ of the bladder who were treated with conventional therapy (resection and/or fulguration) and intravesical bacillus Calmette-Guerin (BCG) without intradermal BCG, and those patients who were treated with conventional therapy alone, we found a response rate of 60 per cent versus 40 per cent at the end of three months. In comparing those patients with superficial papillary cancer, we found a response of 39 per cent after conventional therapy and 63 per cent after conventional therapy and intravesical BCG. This suggests that intravesical BCG without intradermal BCG can be an important adjunct to the conventional therapy of bladder tumors.

  5. Does apical negative pressure prevent the apical extrusion of debris and irrigant compared with conventional irrigation? A systematic review and meta-analysis.

    PubMed

    Romualdo, Priscilla Coutinho; de Oliveira, Katharina Morant Holanda; Nemezio, Mariana Alencar; Küchler, Erika Calvano; Silva, Raquel Assed Bezerra; Nelson-Filho, Paulo; Silva, Lea Assed Bezerra

    2017-12-01

    The aim of this study was to evaluate if apical negative pressure (ANP) irrigation prevents the apical extrusion of debris and irrigant compared with conventional needle irrigation through a systematic review and meta-analysis. A computer search of dental literature was performed using four different databases. A combination of the terms 'apical negative pressure', 'endovac', 'apical extrusion', 'extrusion' and 'endodontics' was used. Studies that used extracted human teeth with a mature apex and that evaluated the apical extrusion of debris and/or irrigating solution were included. After an evaluation of the full studies according to the eligibility criteria, eight studies were critically analysed and subjected to quality assessment and risk of bias. Only four studies that evaluated extrusion of irrigant were considered as having high methodological quality and were subjected to a meta-analysis. Studies evaluating extrusion of debris did not have sufficient methodological quality to be subjected to the meta-analysis. The forest plot indicated that ANP irrigation prevents the risk of irrigant extrusion compared with conventional irrigation (OR 0.07 [95%CI 0.02-0.20]; P < 0.00001). This systematic review and meta-analysis showed that ANP prevents the apical extrusion of irrigant. There is no evidence if this type of irrigation prevents the extrusion of debris. © 2017 Australian Society of Endodontology Inc.

  6. Efficacy and safety of add on low-dose mirtazapine in depression.

    PubMed

    Matreja, Prithpal S; Badyal, Dinesh K; Deswal, Randhir S; Sharma, Arvind

    2012-03-01

    Although antidepressant medications are effective, they have a delayed onset of effect. Mirtazapine, an atypical antidepressant is an important option for add-on therapy in major depression. There is insufficient data on mirtazapine in Indian population; hence this study was designed to study the add-on effect of low-dose mirtazapine with selective serotonin reuptake inhibitors (SSRIs) in major depressive disorder (MDD) in Indian population. In an open, randomized study, 60 patients were divided into two groups. In Group A (n=30) patients received conventional SSRIs for 6 weeks. In Group B (n=30) patients received conventional SSRIs with low-dose mirtazapine for 6 weeks. Patients were evaluated at baseline and then at 1, 2, 3, 4, 5, and 6 weeks. There was significant improvement in Hamilton Depression Rating Scale (HDRS), Montgomery and Asberg depression rating scale (MADRS) scores (P<0.05) in both groups. Mirtazapine in low dose as add on therapy showed improvement in scores, had earlier onset of action, and more number of responders and remitters as compared to conventional treatment (P<0.05). No serious adverse event was reported in either of the groups. Low-dose mirtazapine as add-on therapy has shown better efficacy, earlier onset of action and more number of responders and remitters as compared to conventional treatment in MDD in Indian patients.

  7. Oral 5-aminosalicylic acid for maintenance of remission in ulcerative colitis.

    PubMed

    Wang, Yongjun; Parker, Claire E; Feagan, Brian G; MacDonald, John K

    2016-05-09

    Oral 5-aminosalicylic (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs were more effective than placebo but had a statistically significant therapeutic inferiority relative to SASP. This updated review includes more recent studies and evaluates the effectiveness, dose-responsiveness, and safety of 5-ASA preparations used for maintenance of remission in quiescent ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for maintenance of remission in quiescent ulcerative colitis. A secondary objective was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A literature search for relevant studies (inception to 9 July 2015) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled trials with a minimum treatment duration of six months. Studies of oral 5-ASA therapy for treatment of patients with quiescent ulcerative colitis compared with placebo, SASP or other 5-ASA formulations were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA and 5-ASA dose ranging studies were also considered for inclusion. The primary outcome was the failure to maintain clinical or endoscopic remission. Secondary outcomes included adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA formulation, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol and Salofalk). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the risk ratio (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention-to-treat basis. Forty-one studies (8928 patients) were included. The majority of included studies were rated as low risk of bias. Ten studies were rated at high risk of bias. Seven of these studies were single-blind and three studies were open-label. However, two open-label studies and four of the single-blind studies utilized investigator performed endoscopy as an endpoint, which may protect against bias. 5-ASA was significantly superior to placebo for maintenance of clinical or endoscopic remission. Forty-one per cent of 5-ASA patients relapsed compared to 58% of placebo patients (7 studies, 1298 patients; RR 0.69, 95% CI 0.62 to 0.77). There was a trend towards greater efficacy with higher doses of 5-ASA with a statistically significant benefit for the 1 to 1.9 g/day (RR 0.65; 95% CI 0.56 to 0.76) and the > 2 g/day subgroups (RR 0.73, 95% CI 0.60 to 0.89). SASP was significantly superior to 5-ASA for maintenance of remission. Forty-eight per cent of 5-ASA patients relapsed compared to 43% of SASP patients (12 studies, 1655 patients; RR 1.14, 95% CI 1.03 to 1.27). A GRADE analysis indicated that the overall quality of the evidence for the primary outcome for the placebo and SASP-controlled studies was high. No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Twenty-nine per cent of once daily patients relapsed over 12 months compared to 31% of conventionally dosed patients (8 studies, 3127 patients; RR 0.91, 95% CI 0.82 to 1.01). Eleven per cent of patients in the once daily group failed to adhere to their medication regimen compared to 9% of patients in the conventional dosing group (6 studies, 1462 patients; RR 1.22, 95% CI 0.91 to 1.64). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Forty-four per cent of patients in the 5-ASA group relapsed compared to 41% of patients in the 5-ASA comparator group (6 studies, 707 patients; RR 1.08, 95% CI 0.91 to 1.28). A pooled analysis of two studies showed no statistically significant difference in efficacy between Balsalazide 6 g and 3 g/day. Twenty-three per cent of patients in the 6 g/day group relapsed compared to 33% of patients in the 3 g/day group (216 patients; RR 0.76; 95% CI 0.45 to 2.79). One study found Balsalazide 4 g to be superior to 2 g/day. Thirty-seven per cent of patients in the 4 g/day Balsalazide group relapsed compared to 55% of patients in the 2 g/day group (133 patients; RR 0.66; 95% CI 0.45 to 0.97). One study found a statistically significant difference between Salofalk granules 3 g and 1.5 g/day. Twenty-five per cent of patients in the Salofalk 3 g/day group relapsed compared to 39% of patients in the 1.5 g/day group (429 patients; RR 0.65; 95% CI 0.49 to 0.86). Common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache, dyspepsia, and nasopharyngitis. There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, 5-ASA and SASP, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulations and 5-ASA dose ranging studies. The trials that compared 5-ASA and SASP may have been biased in favour of SASP because most trials enrolled patients known to be tolerant to SASP which may have minimized SASP-related adverse events. 5-ASA was superior to placebo for maintenance therapy in ulcerative colitis. However, 5-ASA had a statistically significant therapeutic inferiority relative to SASP. Oral 5-ASA administered once daily is as effective and safe as conventional dosing for maintenance of remission in quiescent ulcerative colitis. There does not appear to be any difference in efficacy or safety between the various formulations of 5-ASA. Patients with extensive ulcerative colitis or with frequent relapses may benefit from a higher dose of maintenance therapy. High dose therapy appears to be as safe as low dose and is not associated with a higher incidence of adverse events.

  8. Wound Healing Potential of Intermittent Negative Pressure under Limited Access Dressing in Burn Patients: Biochemical and Histopathological Study

    PubMed Central

    Muguregowda, Honnegowda Thittamaranahalli; Kumar, Pramod; Govindarama, Padmanabha Udupa Echalasara

    2018-01-01

    BACKGROUND Malondialdehyde (MDA) is an oxidant that causes damage to membranes, DNA, proteins, and lipids at the cellular level. Antioxidants minimize the effects of oxidants and thus help in formation of healthy granulation tissues with higher level of hydroxyproline and total protein. This study compared the effect of limited access dressing (LAD) with conventional closed dressing biochemically and histopathologically. METHODS Seventy-two 12-65 years old burn patients with mean wound size of 14 cm2 were divided to two groups of LAD (n=37), and conventional dressing groups (n=35). Various biochemical parameters were measured in granulation tissue. Histopathological analysis of the granulation tissue was studied too. RESULTS LAD group showed significant increase in hydroxyproline, total protein, GSH, and GPx and decrease in MDA levels compared to conventional dressing group. A significant negative correlation between GSH and MDA was noted in LAD group, but in conventional dressing group there was no significant correlation. A significant negative correlation between GPx and MDA was noticed in LAD group, but in conventional dressing group was not significant. There was a histologically fewer inflammatory cells, increased and well organized extracellular matrix deposit, more angiogenesis in LAD group after 10 days while the difference was significant between the groups. CONCLUSION Our study showed a significant reduction in oxidative stress biomarker of MDA, increase in hydroxyproline, total protein, antioxidants and amount of ECM deposition, number of blood vessels and a decrease in the amount of inflammatory cells and necrotic tissues in LAD group indicating the better healing effect of burn wounds. PMID:29651393

  9. Comprehensive non-dimensional normalization of gait data.

    PubMed

    Pinzone, Ornella; Schwartz, Michael H; Baker, Richard

    2016-02-01

    Normalizing clinical gait analysis data is required to remove variability due to physical characteristics such as leg length and weight. This is particularly important for children where both are associated with age. In most clinical centres conventional normalization (by mass only) is used whereas there is a stronger biomechanical argument for non-dimensional normalization. This study used data from 82 typically developing children to compare how the two schemes performed over a wide range of temporal-spatial and kinetic parameters by calculating the coefficients of determination with leg length, weight and height. 81% of the conventionally normalized parameters had a coefficient of determination above the threshold for a statistical association (p<0.05) compared to 23% of those normalized non-dimensionally. All the conventionally normalized parameters exceeding this threshold showed a reduced association with non-dimensional normalization. In conclusion, non-dimensional normalization is more effective that conventional normalization in reducing the effects of height, weight and age in a comprehensive range of temporal-spatial and kinetic parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A comparative evaluation of pain and anxiety levels in 2 different anesthesia techniques: locoregional anesthesia using conventional syringe versus intraosseous anesthesia using a computer-controlled system (Quicksleeper).

    PubMed

    Özer, Senem; Yaltirik, Mehmet; Kirli, Irem; Yargic, Ilhan

    2012-11-01

    The aim of this study was to compare anxiety and pain levels during anesthesia and efficacy of Quicksleeper intraosseous (IO) injection system, which delivers computer-controlled IO anesthesia and conventional inferior alveolar nerve block (IANB) in impacted mandibular third molars. Forty subjects with bilateral impacted mandibular third molars randomly received IO injection or conventional IANB at 2 successive appointments. The subjects received 1.8 mL 2% articaine. IO injection has many advantages, such as enabling painless anesthesia with less soft tissue numbness and quick onset of anesthesia as well as lingual and palatal anesthesia with single needle penetration. Although IO injection is a useful technique commonly used during various treatments in dentistry, the duration of injection takes longer than conventional techniques, there is a possibility of obstruction at the needle tip, and, the duration of the anesthetic effect is inadequate for prolonged surgical procedures. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children

    PubMed Central

    Martial, Lisa C.; Aarnoutse, Rob E.; Schreuder, Michiel F.; Henriet, Stefanie S.; Brüggemann, Roger J. M.; Joore, Manuela A.

    2016-01-01

    Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling. PMID:27941974

  12. Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children.

    PubMed

    Martial, Lisa C; Aarnoutse, Rob E; Schreuder, Michiel F; Henriet, Stefanie S; Brüggemann, Roger J M; Joore, Manuela A

    2016-01-01

    Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling.

  13. Denoising embolic Doppler ultrasound signals using Dual Tree Complex Discrete Wavelet Transform.

    PubMed

    Serbes, Gorkem; Aydin, Nizamettin

    2010-01-01

    Early and accurate detection of asymptomatic emboli is important for monitoring of preventive therapy in stroke-prone patients. One of the problems in detection of emboli is the identification of an embolic signal caused by very small emboli. The amplitude of the embolic signal may be so small that advanced processing methods are required to distinguish these signals from Doppler signals arising from red blood cells. In this study instead of conventional discrete wavelet transform, the Dual Tree Complex Discrete Wavelet Transform was used for denoising embolic signals. Performances of both approaches were compared. Unlike the conventional discrete wavelet transform discrete complex wavelet transform is a shift invariant transform with limited redundancy. Results demonstrate that the Dual Tree Complex Discrete Wavelet Transform based denoising outperforms conventional discrete wavelet denoising. Approximately 8 dB improvement is obtained by using the Dual Tree Complex Discrete Wavelet Transform compared to the improvement provided by the conventional Discrete Wavelet Transform (less than 5 dB).

  14. Comparison of particulate lead levels for different ammunition types used with the M16 rifle. Final report, July 1987-June 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoke, S.H.; Beard, A.S.; Brueggemann, E.E.

    1988-07-01

    Airborne lead generated during firing of conventional ammunition has lead to health concerns at indoor firing ranges. This study compares the relative amounts of airborne lead produced by the M16 rifle firing the M193 standard M16 5.56-mm conventional ammunition, the M862 5.56-mm plastic training ammunition, and the conventional caliber .22 rifle cartridge. Both breech and breech-plus-muzzle lead emissions were determined for each type of ammunition.

  15. Fuel Consumption Sensitivity of Conventional and Hybrid Electric Light-Duty Gasoline Vehicles to Driving Style

    DOE PAGES

    Thomas, John; Huff, Shean; West, Brian; ...

    2017-08-11

    Aggressive driving is a very important topic for many reasons, one of which is higher energy used per unit distance traveled, potentially accompanied by an elevated production of greenhouse gases and other pollutants. Examining a large data set of self-reported fuel economy (FE) values revealed that the dispersion of FE values is quite large and is larger for hybrid electric vehicles (HEVs) than for conventional gasoline vehicles. This occurred despite the fact that the city and highway FE ratings for HEVs are generally much closer in value than for conventional gasoline vehicles. A study was undertaken to better understand thismore » and better quantify the effects of aggressive driving, including reviewing past aggressive driving studies, developing and exercising a new vehicle energy model, and conducting a related experimental investigation. The vehicle energy model focused on the limitations of regenerative braking in combination with varying levels of driving-style aggressiveness to show that this could account for greater FE variation in an HEV compared to a similar conventional vehicle. A closely matched pair of gasoline-fueled sedans, one an HEV and the other having a conventional powertrain, was chosen for both modeling and chassis dynamometer experimental comparisons. Results indicate that the regenerative braking limitations could be a main contributor to the greater HEV FE variation under the range of drive cycles considered. Finally, the complete body of results gives insight into the range of fuel use penalties that results from aggressive driving and why the variation can be larger on a percent basis for an HEV compared to a similar conventional vehicle, while the absolute fuel use penalty for aggressive driving is generally larger for conventional vehicles than HEVs.« less

  16. Clinical equivalence assessment of T2 synthesized pediatric brain magnetic resonance imaging.

    PubMed

    Kerleroux, Basile; Kober, Tobias; Hilbert, Tom; Serru, Maxence; Sirinelli, Dominique; Morel, Baptiste

    2018-05-04

    Automated synthetic magnetic resonance imaging (MRI) provides qualitative, weighted image contrasts as well as quantitative information from one scan and is well-suited for various applications such as analysis of white matter disorders. However, the synthesized contrasts have been poorly evaluated in pediatric applications. The purpose of this study was to compare the image quality of synthetic T2 to conventional turbo spin echo (TSE) T2 in pediatric brain MRI. This was a mono-center prospective study. Synthetic and conventional MRI acquisitions at 1.5 Tesla were performed for each patient during the same session using a prototype accelerated T2 mapping sequence package (TA synthetic =3:07min, TA conventional =2:33min). Image sets were blindly and randomly analyzed by pediatric neuro-radiologists. Global image quality, morphologic legibility of standard structures and artifacts were assessed using a 4-point Likert scale. Inter-observer kappa agreements were calculated. The capability of the synthesized contrasts and conventional TSE T2 to discern normal and pathologic cases was evaluated. Sixty patients were included. The overall diagnostic quality of the synthesized contrasts was non-inferior to conventional imaging scale (p=0.06). There was no significant difference in the legibility of normal and pathological anatomic structures of synthetized and conventional TSE T2 (all p > 0.05) as well as for artifacts except for phase encoding (p=0.008). Interobserver agreement was good to almost perfect (kappa between 0.66 and 1). T2 synthesized contrasts, which also provides quantitative T2 information that could be useful, could be suggested as an equivalent technique in pediatric neuro-imaging, compared to conventional TSE T2. Copyright © 2018. Published by Elsevier Masson SAS.

  17. Fuel Consumption Sensitivity of Conventional and Hybrid Electric Light-Duty Gasoline Vehicles to Driving Style

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, John; Huff, Shean; West, Brian

    Aggressive driving is a very important topic for many reasons, one of which is higher energy used per unit distance traveled, potentially accompanied by an elevated production of greenhouse gases and other pollutants. Examining a large data set of self-reported fuel economy (FE) values revealed that the dispersion of FE values is quite large and is larger for hybrid electric vehicles (HEVs) than for conventional gasoline vehicles. This occurred despite the fact that the city and highway FE ratings for HEVs are generally much closer in value than for conventional gasoline vehicles. A study was undertaken to better understand thismore » and better quantify the effects of aggressive driving, including reviewing past aggressive driving studies, developing and exercising a new vehicle energy model, and conducting a related experimental investigation. The vehicle energy model focused on the limitations of regenerative braking in combination with varying levels of driving-style aggressiveness to show that this could account for greater FE variation in an HEV compared to a similar conventional vehicle. A closely matched pair of gasoline-fueled sedans, one an HEV and the other having a conventional powertrain, was chosen for both modeling and chassis dynamometer experimental comparisons. Results indicate that the regenerative braking limitations could be a main contributor to the greater HEV FE variation under the range of drive cycles considered. Finally, the complete body of results gives insight into the range of fuel use penalties that results from aggressive driving and why the variation can be larger on a percent basis for an HEV compared to a similar conventional vehicle, while the absolute fuel use penalty for aggressive driving is generally larger for conventional vehicles than HEVs.« less

  18. Comparison of atomization characteristics of drop-in and conventional jet fuels

    NASA Astrophysics Data System (ADS)

    Kannaiyan, Kumaran; Sadr, Reza; Micro Scale Thermo-Fluids Lab Team

    2016-11-01

    Surge in energy demand and stringent emission norms have been driving the interest on alternative drop-in fuels in aviation industry. The gas-to-liquid (GTL), synthetic paraffinic kerosene fuel derived from natural gas, has drawn significant attention as drop-in fuel due to its cleaner combustion characteristics when compared to other alternative fuels derived from various feedstocks. The fuel specifications such as chemical and physical properties of drop-in fuels are different from those of the conventional jet fuels, which can affect their atomization characteristics and in turn the combustion performance. The near nozzle liquid sheet dynamics of the drop-in fuel, GTL, is studied at different nozzle operating conditions and compared with that of the conventional Jet A-1 fuel. The statistical analysis of the near nozzle sheet dynamics shows that the drop-in fuel atomization characteristics are comparable to those of the conventional fuel. Furthermore, the microscopic spray characteristics measured using phase Doppler anemometry at downstream locations are slightly different between the fuels. Authors acknowledge the support by National Priorities Research Program (NPRP) of Qatar National Research Fund through the Grant NPRP-7-1449-2-523.

  19. Effects of a malfunctional column on conventional and FeedCol-simulated moving bed chromatography performance.

    PubMed

    Song, Ji-Yeon; Oh, Donghoon; Lee, Chang-Ha

    2015-07-17

    The effects of a malfunctional column on the performance of a simulated moving bed (SMB) process were studied experimentally and theoretically. The experimental results of conventional four-zone SMB (2-2-2-2 configuration) and FeedCol operation (2-2-2-2 configuration with one feed column) with one malfunctional column were compared with simulation results of the corresponding SMB processes with a normal column configuration. The malfunctional column in SMB processes significantly deteriorated raffinate purity. However, the extract purity was equivalent or slightly improved compared with the corresponding normal SMB operation because the complete separation zone of the malfunctional column moved to a lower flow rate range in zones II and III. With the malfunctional column configuration, FeedCol operation gave better experimental performance (up to 7%) than conventional SMB operation because controlling product purity with FeedCol operation was more flexible through the use of two additional operating variables, injection time and injection length. Thus, compared with conventional SMB separation, extract with equivalent or slightly better purity could be produced from FeedCol operation even with a malfunctional column, while minimizing the decrease in raffinate purity (less than 2%). Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Computational fluid dynamics evaluation of the cross-limb stent graft configuration for endovascular aneurysm repair.

    PubMed

    Shek, Tina L T; Tse, Leonard W; Nabovati, Aydin; Amon, Cristina H

    2012-12-01

    The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the "direct" and "cross" configurations, respectively). We also added a "planar" configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient's cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct configuration.

  1. Leaching of indium from obsolete liquid crystal displays: Comparing grinding with electrical disintegration in context of LCA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodbiba, Gjergj, E-mail: dodbiba@sys.t.u-tokyo.ac.jp; Nagai, Hiroki; Wang Lipang

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Two pre-treatment methods, prior to leaching of indium from obsolete LCD modules, were described. Black-Right-Pointing-Pointer Conventional grinding and electrical disintegration have been evaluated and compared in the context of LCA. Black-Right-Pointing-Pointer Experimental data on the leaching capacity for indium and the electricity consumption of equipment were inputted into the LCA model in order to compare the environmental performance of each method. Black-Right-Pointing-Pointer An estimate for the environmental performance was calculated as the sum of six impact categories. Black-Right-Pointing-Pointer Electrical disintegration method outperforms conventional grinding in all impact categories. - Abstract: In order to develop an effective recycling systemmore » for obsolete Liquid Crystal Displays (LCDs), which would enable both the leaching of indium (In) and the recovery of a pure glass fraction for recycling, an effective liberation or size-reduction method would be an important pre-treatment step. Therefore, in this study, two different types of liberation methods: (1) conventional grinding, and (2) electrical disintegration have been tested and evaluated in the context of Life Cycle Assessment (LCA). In other words, the above-mentioned methods were compared in order to find out the one that ensures the highest leaching capacity for indium, as well as the lowest environmental burden. One of the main findings of this study was that the electrical disintegration was the most effective liberation method, since it fully liberated the indium containing-layer, ensuring a leaching capacity of 968.5 mg-In/kg-LCD. In turn, the estimate for the environmental burden was approximately five times smaller when compared with the conventional grinding.« less

  2. Impact of facial form on the relationship between conventional or implant-assisted mandibular dentures and masticatory function.

    PubMed

    Ochiai, Kent T; Hojo, Satoru; Nakamura, Camille; Ikeda, Hideki; Garrett, Neal R

    2011-04-01

    It is not clear if the interaction of craniofacial form with type of prosthetic restoration (conventional or implant-assisted) is related to masticatory function in complete denture patients. The purpose of this study was to investigate the relationships among facial form, skeletal class, alveolar residual ridge heights and masticatory function in subjects treated with implant-assisted or conventional mandibular dentures with lateral cephalometric evaluation. Data from a previously reported randomized controlled clinical trial were accessed to compare treatment success rates, functional and perceptual outcomes, dietary intake, and craniofacial relationships between mandibular complete dentures and implant overdentures in edentulous diabetic subjects. Evaluation of the digitized post-insertion lateral cephalometric radiographs provided measures of facial form (mesocephalic "medium", brachycephalic "broad and square", dolichocephalic "vertical and long"), skeletal class (Class I, Class II, Class III), and alveolar ridge height (mm), which were compared to results of standardized masticatory tests as evaluated using MANOVA and REGW post-hoc evaluation (α=.05). Masticatory performance on the preferred side was slightly reduced in the dolichocephalic group, compared to brachycephalic and mesocephalic groups (P=.085). Swallowing threshold performance was significantly less in skeletal Class II subjects compared to Class I (P=.034). Maxillary residual alveolar ridge height was significantly less in the brachycephalic group compared to the dolichocephalic group (P<.001). No differences in mandibular ridge height were seen associated with facial form or skeletal class groups. Facial form may be related to masticatory function with conventional and implant-assisted mandibular dentures, but larger controlled studies are needed to confirm this relationship. Alveolar ridge height is reduced in edentulous subjects with a brachycephalic facial form. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  3. Pilot randomized trial for treatment of bacterial vaginosis using in situ forming metronidazole vaginal gel.

    PubMed

    Shaaban, Omar M; Fetih, Gihan N; Abdellah, Noura H; Ismail, Saeyd; Ibrahim, Maggie A; Ibrahim, El-sayed A

    2011-07-01

    To compare the efficacy of a novel vaginal delivery system for metronidazole (0.8% MTZ in situ gel) versus a conventional MTZ vaginal gel product in the treatment of bacterial vaginosis (BV). All consecutive patients who presented to a tertiary care hospital with symptoms suggestive of BV were approached to participate in the study. Forty-two eligible participants were randomly assigned to either MTZ in situ gel or a conventional vaginal gel product twice daily for 5 days. All participants were re-examined after one and 4 weeks of the beginning of treatment to ensure cure of infection and any side-effects. Demographic criteria of the participants were comparable in the two treatment groups. The cure rate after one week from the treatment was 85% in the in situ gel group and 71.4% in the conventional vaginal gel group (P = 0.294), while after 4 weeks, the cure rate showed significant difference in the in situ gel group as compared to the conventional vaginal gel group (16/20 [80%]) and (9/19 [47.4%]), respectively (P = 0.034). Pilot testing showed that in situ MTZ vaginal gel is more effective than the conventional vaginal gel for long-term cure of BV. These findings suggest a novel and efficient long-term treatment of BV. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  4. Is meat quality of forage-fed steers comparable to the meat quality of conventional beef from concentrate-fed bulls?

    PubMed

    Blanco, Mireia; Casasús, Isabel; Ripoll, Guillermo; Albertí, Pere; Panea, Begoña; Joy, Margalida

    2017-11-01

    Replacing concentrates with forages in the diet of finishing cattle to satisfy societal demands and for economic reasons is a target for beef farmers, but this change may affect meat acceptance. In the Mediterranean area, young bulls are usually finished on concentrates (Conventional beef). Alternatively, steers can be finished on grass with supplements (G-supp); however, if carcasses are too lean, meat quality may be negatively affected. To increase fat deposition, grazing steers were finished on a total mixed ration composed of alfalfa hay and corn (TMR). Thus the objective of the study was to compare the quality of Longissimus muscle of the three systems. Conventional beef had low yellowness and similar lightness and redness values compared with the beef from the forage-based systems, which differed slightly. The meat of the G-supp and TMR steers had higher conjugated linoleic acid (CLA) and total n-3 polyunsaturated fatty acid (PUFA) contents and lower n-6/n-3 PUFA ratio (more appropriate from a human health point of view) but was tougher than the Conventional beef. The Conventional beef was better accepted by consumers than the beef from both forage-based systems because it was the most tender. Thus tenderness of meat from forage-fed steers should be improved to ensure consumer acceptance. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review.

    PubMed

    Longoni, Juliano N; Lopes, Beatriz M; Freires, Irlan A; Dutra, Kamile L; Franco, Ademir; Paranhos, Luiz R

    2017-01-01

    The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans , 2 studies showed less accumulation in self-ligating than in conventional brackets. Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient - such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity.

  6. Calcium channel blockers in hypertension: reappraisal after new trials and major meta-analyses.

    PubMed

    Opie, L H

    2001-10-01

    This review evaluates the current position of calcium channel blockers (CCB) in antihypertensive treatment in the light of three major comparative studies and two extensive meta-analyses. The latter both show that CCB are equivalent to conventional (initial beta-blocker or diuretic therapy) when total and cardiovascular mortality are the end points. Divergent points between the meta-analyses include stroke and myocardial infarction (MI). One meta-analysis compared CCB with conventional therapy, to find a small 13% reduction in stroke and a small, nonsignificant 12% increase in MI. The other meta-analysis found a 26% increase in MI when CCB were compared with all other therapies including the angiotensin converting enzyme (ACE) inhibitors. This increase was most robust (P < .001) when comparing CCB with ACE inhibitors, consonant with proposed protective effects of ACE inhibitors on cardiovascular risk. At present, only the comparison of CCB with conventional therapy, and not that with ACE inhibitors, rests on secure comparative data. When cost is compelling, conventional therapy is less expensive. For the individual patient, issues of quality of life (for example, impotence with diuretics and beta-blockers) might be decisive. Nonetheless, beta-blockers are preferred in postinfarct patients or in those with heart failure or unstable angina (a contraindication to dihydropyridines in the absence of beta-blockade). In others, the benefits of only a borderline stroke reduction with CCB versus an equally borderline increase in MI should be evaluated for each individual patient, taking into account the age group and the patient's preferences. In conclusion, overall CCB are neither better nor worse than conventional therapy, allowing for possible small differences in stroke and MI. The ACE inhibitors may protect better, although data are incomplete.

  7. Comparison of Effects of Teaching English to Thai Undergraduate Teacher-Students through Cross-Curricular Thematic Instruction Program Based on Multiple Intelligence Theory and Conventional Instruction

    ERIC Educational Resources Information Center

    Rattanavich, Saowalak

    2013-01-01

    This study is aimed at comparing the effects of teaching English to Thai undergraduate teacher-students through cross-curricular thematic instruction program based on multiple intelligence theory and through conventional instruction. Two experimental groups, which utilized Randomized True Control Group-Pretest-posttest Time Series Design and…

  8. Assessing the Impact of Learning Environments on Students' Approaches to Learning: Comparing Conventional and Action Learning Designs

    ERIC Educational Resources Information Center

    Wilson, Keithia; Fowler, Jane

    2005-01-01

    This study investigated whether students' approaches to learning were influenced by the design of university courses. Pre- and post-evaluations of the approaches to learning of the same group of students concurrently enrolled in a conventional course (lectures and tutorials) and an action learning-based course (project work, learning groups) were…

  9. In Situ Fixation of Metal(loid)s in Contaminated Soils: A Comparison of Conventional, Opportunistic, and Engineered Soil Amendments

    EPA Science Inventory

    This study aimed to assess and compare the in vitro and in vivo bioaccessibility/bioavailability of As and Pb in a mining contaminated soil (As 2267 mg kg-1, Pb 1126 mg kg-1), after the addition of conventional (phosphoric acid), opportunistic ...

  10. Assessment of the Equivalence of Conventional versus Computer Administration of the Test of Workplace Essential Skills

    ERIC Educational Resources Information Center

    Whiting, Hal; Kline, Theresa J. B.

    2006-01-01

    This study examined the equivalency of computer and conventional versions of the Test of Workplace Essential Skills (TOWES), a test of adult literacy skills in Reading Text, Document Use and Numeracy. Seventy-three college students completed the computer version, and their scores were compared with those who had taken the test in the conventional…

  11. In vitro and in vivo Efficacy of New Blue Light Emitting Diode Phototherapy Compared to Conventional Halogen Quartz Phototherapy for Neonatal Jaundice

    PubMed Central

    Chang, Yun Sil; Hwang, Jong Hee; Kwon, Hyuk Nam; Choi, Chang Won; Ko, Sun Young; Park, Won Soon; Shin, Son Moon

    2005-01-01

    High intensity light emitting diodes (LEDs) are being studied as possible light sources for the phototherapy of neonatal jaundice, as they can emit high intensity light of narrow wavelength band in the blue region of the visible light spectrum corresponding to the spectrum of maximal bilirubin absorption. We developed a prototype blue gallium nitride LED phototherapy unit with high intensity, and compared its efficacy to commercially used halogen quartz phototherapy device by measuring both in vitro and in vivo bilirubin photodegradation. The prototype device with two focused arrays, each with 500 blue LEDs, generated greater irradiance than the conventional device tested. The LED device showed a significantly higher efficacy of bilirubin photodegradation than the conventional phototherapy in both in vitro experiment using microhematocrit tubes (44±7% vs. 35±2%) and in vivo experiment using Gunn rats (30±9% vs. 16±8%). We conclude that high intensity blue LED device was much more effective than conventional phototherapy of both in vitro and in vivo bilirubin photodegradation. Further studies will be necessary to prove its clinical efficacy. PMID:15716604

  12. Computational Design of a Krueger Flap Targeting Conventional Slat Aerodynamics

    NASA Technical Reports Server (NTRS)

    Akaydin, H. Dogus; Housman, Jeffrey A.; Kiris, Cetin C.; Bahr, Christopher J.; Hutcheson, Florence V.

    2016-01-01

    In this study, we demonstrate the design of a Krueger flap as a substitute for a conventional slat in a high-lift system. This notional design, with the objective of matching equivalent-mission performance on aircraft approach, was required for a comparative aeroacoustic study with computational and experimental components. We generated a family of high-lift systems with Krueger flaps based on a set of design parameters. Then, we evaluated the high-lift systems using steady 2D RANS simulations to find a good match for the conventional slat, based on total lift coefficients in free-air. Finally, we evaluated the mean aerodynamics of the high-lift systems with Krueger flap and conventional slat as they were installed in an open-jet wind tunnel flow. The surface pressures predicted with the simulations agreed well with experimental results.

  13. Maxillary incisors changes during space closure with conventional and skeletal anchorage methods: a systematic review.

    PubMed

    Jayaratne, Yasas Shri Nalaka; Uribe, Flavio; Janakiraman, Nandakumar

    2017-01-01

    The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes) and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration) were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. More RCT's that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  14. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    PubMed Central

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  15. [Experimental research on the effect of nanophase ceramics on osteoblasts functions].

    PubMed

    Wen, Bo; Chen, Zhiqing; Jiang, Yinshan; Yang, Zhengwen; Xu, Yongzhong

    2005-06-01

    In order to study the cytocompatibility of nanophase hydroxyapatite ceramic in vitro, we prepared hydroxyapatite by use of the wet chemistry techniques. The grain size of hydroxyapatite of interest to the present study was determined by scanning electron microscopy and atomic force microscopy with image analysis software. Primary culture of osteoblast from rat calvaria was established. Protein content, synthesis of alkaline phosphatase and deposition of calcium-containing mineral by osteoblasts cultured on nanophase hydroxyapatite ceramics and on conventional hydroxyapatite ceramics for 7, 14, 21 and 28 days were examined. The results showed that the average surface grain size of the nanophase and that of the conventional HA compact formulations was 55 (nanophase) and 780 (conventional) nm, respectively. More importantly, compared to the synthesis of alkaline phosphatase and deposition of calcium-containing mineral by osteoblasts cultured on nanophase was significantly greater than that on conventional ceramics after 21 and 28 days. The cytocompatibility was significantly greater on nanophase HA than on conventional formulations of the same ceramic.

  16. Apparent diffusion coefficient in glioblastoma with PNET-like components, a GBM variant.

    PubMed

    Ali, Saad; Joseph, Nancy M; Perry, Arie; Barajas, Ramon F; Cha, Soonmee

    2014-09-01

    Glioblastoma (GBM) with primitive neuroectodermal tumor (PNET)-like (GBM-PNET) components is a rare variant of GBM. Recent studies describe PNET-like clinical behavior in these patients-with significantly increased propensity for CSF dissemination and a benefit of "PNET-like" chemotherapy. The imaging appearance of GBM-PNET is not well-described and given areas of marked cellularity in the PNET components one might expect significantly reduced diffusion on MRI. The purpose of this study is to quantitatively evaluate the diffusion characteristics in GBM-PNET and compare them with conventional GBMs. Nine patients with surgical specimens yielding GBM-PNET were identified from the UCSF Pathology files. MR images of these patients were reviewed retrospectively. DWI (diffusion-weighted imaging) sequences were analyzed with multiple regions of interests placed within the tumor, and ADC (apparent diffusion coefficient) values were measured. Results were compared to previously published ADC values in pathology-proven conventional GBM cases from our institution. Reduced ADC was seen in GBM-PNET (mean 581 × 10(-6) mm(2)/s, range 338-817) compared to previously published mean of 1,030 × 10(-6) mm(2)/s in the enhancing components of conventional GBMs. We report substantially reduced ADC values in GBM-PNETs compared to conventional GBMs. If demonstrated in a larger sample, when areas of marked reduced diffusion are seen in a suspected GBM, MRI may appropriately direct tissue sampling and can advocate a thorough search for PNET-like components on histopathology. These patients may have a higher chance of developing CSF dissemination and may benefit from "PNET-like" platinum-based chemotherapy.

  17. A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions – An In Vitro Study

    PubMed Central

    Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir

    2014-01-01

    Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318

  18. An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniques.

    PubMed

    Bergin, Junping Ma; Rubenstein, Jeffrey E; Mancl, Lloyd; Brudvik, James S; Raigrodski, Ariel J

    2013-10-01

    Conventional impression techniques for recording the location and orientation of implant-supported, complete-arch prostheses are time consuming and prone to error. The direct optical recording of the location and orientation of implants, without the need for intermediate transfer steps, could reduce or eliminate those disadvantages. The objective of this study was to assess the feasibility of using a photogrammetric technique to record the location and orientation of multiple implants and to compare the results with those of a conventional complete-arch impression technique. A stone cast of an edentulous mandibular arch containing 5 implant analogs was fabricated to create a master model. The 3-dimensional (3D) spatial orientations of implant analogs on the master model were measured with a coordinate measuring machine (CMM) (control). Five definitive casts were made from the master model with a splinted impression technique. The positions of the implant analogs on the 5 casts were measured with a NobelProcera scanner (conventional method). Prototype optical targets were attached to the master model implant analogs, and 5 sets of images were recorded with a digital camera and a standardized image capture protocol. Dimensional data were imported into commercially available photogrammetry software (photogrammetric method). The precision and accuracy of the 2 methods were compared with a 2-sample t test (α=.05) and a 95% confidence interval. The location precision (standard error of measurement) for CMM was 3.9 µm (95% CI 2.7 to 7.1), for photogrammetry, 5.6 µm (95% CI 3.4 to 16.1), and for the conventional method, 17.2 µm (95% CI 10.3 to 49.4). The average measurement error was 26.2 µm (95% CI 15.9 to 36.6) for the conventional method and 28.8 µm (95% CI 24.8 to 32.9) for the photogrammetric method. The overall measurement accuracy was not significantly different when comparing the conventional to the photogrammetric method (mean difference = -2.6 µm, 95% CI -12.8 to 7.6). The precision of the photogrammetric method was similar to CMM, but lower for the conventional method as compared to CMM and the photogrammetric method. However, the overall measurement accuracy of the photogrammetric and conventional methods was similar. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  19. Reliability of patient specific instrumentation in total knee arthroplasty.

    PubMed

    Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David

    2015-12-01

    The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.

  20. Center index method-an alternative for wear measurements with radiostereometry (RSA).

    PubMed

    Dahl, Jon; Figved, Wender; Snorrason, Finnur; Nordsletten, Lars; Röhrl, Stephan M

    2013-03-01

    Radiostereometry (RSA) is considered to be the most precise and accurate method for wear-measurements in total hip replacement. Post-operative stereoradiographs has so far been necessary for wear measurement. Hence, the use of RSA has been limited to studies planned for RSA measurements. We compared a new RSA method for wear measurements that does not require previous radiographs with conventional RSA. Instead of comparing present stereoradiographs with post-operative ones, we developed a method for calculating the post-operative position of the center of the femoral head on the present examination and using this as the index measurement. We compared this alternative method to conventional RSA in 27 hips in an ongoing RSA study. We found a high degree of agreement between the methods for both mean proximal (1.19 mm vs. 1.14 mm) and mean 3D wear (1.52 mm vs. 1.44 mm) after 10 years. Intraclass correlation coefficients (ICC) were 0.958 and 0.955, respectively (p<0.001 for both ICCs). The results were also within the limits of agreement when plotted subject-by-subject in a Bland-Altman plot. Our alternative method for wear measurements with RSA offers comparable results to conventional RSA measurements. It allows precise wear measurements without previous radiological examinations. Copyright © 2012 Orthopaedic Research Society.

  1. User-composable Electronic Health Record Improves Efficiency of Clinician Data Viewing for Patient Case Appraisal: A Mixed-Methods Study

    PubMed Central

    Senathirajah, Yalini; Kaufman, David; Bakken, Suzanne

    2016-01-01

    Background: Challenges in the design of electronic health records (EHRs) include designing usable systems that must meet the complex, rapidly changing, and high-stakes information needs of clinicians. The ability to move and assemble elements together on the same page has significant human-computer interaction (HCI) and efficiency advantages, and can mitigate the problems of negotiating multiple fixed screens and the associated cognitive burdens. Objective: We compare MedWISE—a novel EHR that supports user-composable displays—with a conventional EHR in terms of the number of repeat views of data elements for patient case appraisal. Design and Methods: The study used mixed-methods for examination of clinical data viewing in four patient cases. The study compared use of an experimental user-composable EHR with use of a conventional EHR, for case appraisal. Eleven clinicians used a user-composable EHR in a case appraisal task in the laboratory setting. This was compared with log file analysis of the same patient cases in the conventional EHR. We investigated the number of repeat views of the same clinical information during a session and across these two contexts, and compared them using Fisher’s exact test. Results: There was a significant difference (p<.0001) in proportion of cases with repeat data element viewing between the user-composable EHR (14.6 percent) and conventional EHR (72.6 percent). Discussion and Conclusion: Users of conventional EHRs repeatedly viewed the same information elements in the same session, as revealed by log files. Our findings are consistent with the hypothesis that conventional systems require that the user view many screens and remember information between screens, causing the user to forget information and to have to access the information a second time. Other mechanisms (such as reduction in navigation over a population of users due to interface sharing, and information selection) may also contribute to increased efficiency in the experimental system. Systems that allow a composable approach that enables the user to gather together on the same screen any desired information elements may confer cognitive support benefits that can increase productive use of systems by reducing fragmented information. By reducing cognitive overload, it can also enhance the user experience. PMID:27195306

  2. Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery.

    PubMed

    McClelland, Jodie A; Webster, Kate E; Ramteke, Alankar A; Feller, Julian A

    2017-06-01

    Computer-assisted navigation in total knee arthroplasty (TKA) reduces variability and may improve accuracy in the postoperative static alignment. The effect of navigation on alignment and biomechanics during more dynamic movements has not been investigated. This study compared knee biomechanics during level walking of 121 participants: 39 with conventional TKA, 42 with computer-assisted navigation TKA and 40 unimpaired control participants. Standing lower-limb alignment was significantly closer to ideal in participants with navigation TKA. During gait, when differences in walking speed were accounted for, participants with conventional TKA had less knee flexion during stance and swing than controls (P<0.01), but there were no differences between participants with navigation TKA and controls for the same variables. Both groups of participants with TKA had lower knee adduction moments than controls (P<0.01). In summary, there were fewer differences in the biomechanics of computer-assisted navigation TKA patients compared to controls than for patients with conventional TKA. Computer-assisted navigation TKA may restore biomechanics during walking that are closer to normal than conventional TKA. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Conventional and thermophilic aerobic treatability of high strength oily pet food wastewater using membrane-coupled bioreactors.

    PubMed

    Kurian, R; Acharya, C; Nakhla, G; Bassi, A

    2005-11-01

    Although thermophilic treatment systems have recently gained considerable interest, limited information exists on the comparative performances of membrane-coupled bioreactors (MBR) at thermophilic and conventional conditions. In this study aerobic MBRs operating at room temperature (20 degrees C) and at lower thermophilic range (45 degrees C) were investigated for the treatment of dissolved air flotation (DAF) pretreated pet food wastewater. The particular wastewater is characterized by oil and grease (O & G) concentrations as high as 6 g/L, COD of 51 g/L, BOD of 16 g/L and volatile fatty acid (VFA) of 8.3 g/L. The performances of the two systems in terms of COD, BOD and O & G removal at varying hydraulic retention time (HRT) are compared. COD removal efficiencies in the thermophilic MBR varied from 75% to 98% and remained constant at 94% in the conventional MBR. The O & G removal efficiencies were 66-86% and 98% in the thermophilic and conventional MBR, respectively. Interestingly, high concentrations of VFA were recorded, equivalent to 50-73% of total COD, in the thermophilic MBR effluent. The observed yield in the thermophilic MBR was 40% of that observed in the conventional MBR.

  4. Unidirectional growth of benzil crystal from solution by Sankaranarayanan-Ramasamy method and its characterization.

    PubMed

    Rajalakshmi, M; Shyju, T S; Indirajith, R; Gopalakrishnan, R

    2012-02-01

    Good quality <100> benzil single crystal with a diameter 18 mm and length 75 mm was successfully grown from solution by the unidirectional growth method of Sankaranarayanan-Ramasamy (SR) for the first time in the literature. The seed crystals have been harvested from conventional solution growth technique and subsequently used for unidirectional growth. The grown crystal was subjected to various characterization studies. The results of UV-vis spectral analysis, photoluminescence, etching and microhardness studies were compared with conventional solution grown crystal to that of SR method grown crystal. The quality of SR method grown benzil crystal is better than conventional solution grown crystal. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Conventional Warfare and United States Military Involvement in Latin America: Early Adolescents' Views.

    ERIC Educational Resources Information Center

    Roscoe, Bruce; And Others

    1988-01-01

    Assessed adolescents' views concerning conventional war and compared views to those of adolescents 15 years ago. Surveyed 362 seventh graders regarding conventional warfare and United States military involvement in Latin America. Compared to adolescents in 1971, adolescents in 1986 were somewhat more accepting of war. Many were skeptical of…

  6. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  7. Detection of common diarrhea-causing pathogens in Northern Taiwan by multiplex polymerase chain reaction.

    PubMed

    Huang, Shu-Huan; Lin, Yi-Fang; Tsai, Ming-Han; Yang, Shuan; Liao, Mei-Ling; Chao, Shao-Wen; Hwang, Cheng-Cheng

    2018-06-01

    Conventional methods for identifying gastroenteritis pathogens are time consuming, more likely to result in a false-negative, rely on personnel with diagnostic expertise, and are dependent on the specimen status. Alternatively, molecular diagnostic methods permit the rapid, simultaneous detection of multiple pathogens with high sensitivity and specificity. The present study compared conventional methods with the Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for the diagnosis of infectious gastroenteritis in northern Taiwan. From July 2015 to April 2016, 217 clinical fecal samples were collected from patients with suspected infectious gastroenteritis. All specimens were tested using conventional diagnostic techniques following physicians' orders as well as with the xTAG GPP. The multiplex polymerase chain reaction (PCR) approach detected significantly more positive samples with bacterial, viral, and/or parasitic infections as compared to conventional analysis (55.8% vs 40.1%, respectively; P < .001). Moreover, multiplex PCR could detect Escherichia coli O157, enterotoxigenic E coli, Shiga-like toxin-producing E coli, Cryptosporidium, and Giardia, which were undetectable by conventional methods. Furthermore, 48 pathogens in 23 patients (10.6%) with coinfections were identified only using the multiplex PCR approach. Of which, 82.6% were from pediatric patients. Because the detection rates using multiplex PCR are higher than conventional methods, and some pediatric pathogens could only be detected by multiplex PCR, this approach may be useful in rapidly diagnosing diarrheal disease in children and facilitating treatment initiation. Further studies are necessary to determine if multiplex PCR improves patient outcomes and reduces costs.

  8. Detection of common diarrhea-causing pathogens in Northern Taiwan by multiplex polymerase chain reaction

    PubMed Central

    Huang, Shu-Huan; Lin, Yi-Fang; Tsai, Ming-Han; Yang, Shuan; Liao, Mei-Ling; Chao, Shao-Wen; Hwang, Cheng-Cheng

    2018-01-01

    Abstract Conventional methods for identifying gastroenteritis pathogens are time consuming, more likely to result in a false-negative, rely on personnel with diagnostic expertise, and are dependent on the specimen status. Alternatively, molecular diagnostic methods permit the rapid, simultaneous detection of multiple pathogens with high sensitivity and specificity. The present study compared conventional methods with the Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for the diagnosis of infectious gastroenteritis in northern Taiwan. From July 2015 to April 2016, 217 clinical fecal samples were collected from patients with suspected infectious gastroenteritis. All specimens were tested using conventional diagnostic techniques following physicians’ orders as well as with the xTAG GPP. The multiplex polymerase chain reaction (PCR) approach detected significantly more positive samples with bacterial, viral, and/or parasitic infections as compared to conventional analysis (55.8% vs 40.1%, respectively; P < .001). Moreover, multiplex PCR could detect Escherichia coli O157, enterotoxigenic E coli, Shiga-like toxin-producing E coli, Cryptosporidium, and Giardia, which were undetectable by conventional methods. Furthermore, 48 pathogens in 23 patients (10.6%) with coinfections were identified only using the multiplex PCR approach. Of which, 82.6% were from pediatric patients. Because the detection rates using multiplex PCR are higher than conventional methods, and some pediatric pathogens could only be detected by multiplex PCR, this approach may be useful in rapidly diagnosing diarrheal disease in children and facilitating treatment initiation. Further studies are necessary to determine if multiplex PCR improves patient outcomes and reduces costs. PMID:29879060

  9. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets.

    PubMed

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore de

    2016-01-01

    The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  10. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  11. A multicriteria decision analysis of augmentative treatment of upper limbs in persons with tetraplegia.

    PubMed

    Hummel, J M Marjan; Snoek, Govert J; van Til, Janine A; van Rossum, Wouter; Ijzerman, Maarten J

    2005-01-01

    This study supported the evaluation by a rehabilitation team of the performance of two treatment options that improve the arm-hand function in subjects with sixth cervical vertebra (C6) level Motor Group 2 tetraplegia. The analytic hierarchy process, a technique for multicriteria decision analysis, was used by a rehabilitation team and potential recipients to quantitatively compare a new technology, Functional Elec trical Stimulation (FES), with conventional surgery. Perform-ance was measured by functional improvement, treatment load, risks, user-friendliness, and social outcomes. Functional improvement after FES was considered better than that after conventional surgery. However, the rehabilitation team's overall rating for conventional surgery was slightly higher than that for FES (57% vs 44%). Compared with the rehabilitation team, potential recipients gave greater weight to burden of treatment and less weight to functional improvement. This study shows that evaluation of new technology must be more comprehensive than the evaluation of functional improvement alone, and that patient preferences may differ from those of the rehabilitation team.

  12. Comparative study on conventional, ultrasonication and microwave assisted extraction of γ-oryzanol from rice bran.

    PubMed

    Kumar, Pramod; Yadav, Devbrat; Kumar, Pradyuman; Panesar, Paramjeet Singh; Bunkar, Durga Shankar; Mishra, Diwaker; Chopra, H K

    2016-04-01

    In present study, conventional, ultrasonic and microwave assisted extraction methods were compared with the aim of optimizing best fitting solvent and method, solvent concentration and digestion time for high yield of γ-oryzanol from rice bran. Petroleum ether, hexane and methanol were used to prepare extracts. Extraction yield were evaluated for giving high crude oil yield, total phenolic content (TPC) and γ-oryzanol content. Gas chromatography-mass spectrophotometry was used for the determination of γ-oryzanol concentration. The highest concentration of γ-oryzanol was detected in methanolic extracts of microwave treatment (85.0 ppm) followed by ultrasonication (82.0 ppm) and conventional extraction method (73.5 ppm). Concentration of γ-oryzanol present in the extracts was found to be directly proportional to the total phenolic content. A combination of 80 % methanolic concentration and 55 minutes digestion time of microwave treatment yielded the best extraction method for TPC and thus γ-oryzanol (105 ppm).

  13. Does time-lapse imaging have favorable results for embryo incubation and selection compared with conventional methods in clinical in vitro fertilization? A meta-analysis and systematic review of randomized controlled trials.

    PubMed

    Chen, Minghao; Wei, Shiyou; Hu, Junyan; Yuan, Jing; Liu, Fenghua

    2017-01-01

    The present study aimed to undertake a review of available evidence assessing whether time-lapse imaging (TLI) has favorable outcomes for embryo incubation and selection compared with conventional methods in clinical in vitro fertilization (IVF). Using PubMed, EMBASE, Cochrane library and ClinicalTrial.gov up to February 2017 to search for randomized controlled trials (RCTs) comparing TLI versus conventional methods. Both studies randomized women and oocytes were included. For studies randomized women, the primary outcomes were live birth and ongoing pregnancy, the secondary outcomes were clinical pregnancy and miscarriage; for studies randomized oocytes, the primary outcome was blastocyst rate, the secondary outcome was good quality embryo on Day 2/3. Subgroup analysis was conducted based on different incubation and embryo selection between groups. Ten RCTs were included, four randomized oocytes and six randomized women. For oocyte-based review, the pool-analysis observed no significant difference between TLI group and control group for blastocyst rate [relative risk (RR) 1.08, 95% CI 0.94-1.25, I2 = 0%, two studies, including 1154 embryos]. The quality of evidence was moderate for all outcomes in oocyte-based review. For woman-based review, only one study provided live birth rate (RR 1,23, 95% CI 1.06-1.44,I2 N/A, one study, including 842 women), the pooled result showed no significant difference in ongoing pregnancy rate (RR 1.04, 95% CI 0.80-1.36, I2 = 59%, four studies, including 1403 women) between two groups. The quality of the evidence was low or very low for all outcomes in woman-based review. Currently there is insufficient evidence to support that TLI is superior to conventional methods for human embryo incubation and selection. In consideration of the limitations and flaws of included studies, more well designed RCTs are still in need to comprehensively evaluate the effectiveness of clinical TLI use.

  14. Lumbar spinous process splitting decompression provides equivalent outcomes to conventional midline decompression in degenerative lumbar canal stenosis: a prospective, randomized controlled study of 51 patients.

    PubMed

    Rajasekaran, S; Thomas, Ashok; Kanna, Rishi M; Prasad Shetty, Ajoy

    2013-09-15

    Prospective, randomized controlled study. To compare the functional outcomes and extent of paraspinal muscle damage between 2 decompressive techniques for lumbar canal stenosis. Lumbar spinous process splitting decompression (LSPSD) preserves the muscular and liga-mentous attachments of the posterior elements of the spine. It can potentially avoid problems such as paraspinal muscle atrophy and trunk extensor weakness that can occur after conventional midline decompression. However, large series prospective randomized controlled studies are lacking. Patients with lumbar canal stenosis were randomly allocated into 2 groups: LSPSD (28 patients) and conventional midline decompression (23 patients). The differences in operative time, blood loss, time to comfortable mobilization, and hospital stay were studied. Paraspinal muscle damage was assessed by postoperative rise in creatine phosphokinase and C-reactive protein levels. Functional outcome was evaluated at 1 year by Japanese Orthopaedic Association score, neurogenic claudication outcome score, and visual analogue scale for back pain and neurogenic claudication. Fifty-one patients of mean age 56 years were followed-up for a mean 14.2 ± 2.9 months. There were no significant differences in the operative time, blood loss, and hospital stay. Both the groups showed significant improvement in the functional outcome scores at 1 year. Between the 2 groups, the Japanese Orthopaedic Association score, neurogenic claudication outcome score improvement, visual analogue scale for back pain, neurogenic claudication visual analogue scale, and the postoperative changes in serum C-reactive protein and creatine phosphokinase levels did not show any statistically significant difference. On the basis of the Japanese Orthopaedic Association recovery rate, it was found that 73.9% of conventional midline decompression group had good outcomes compared with only 60.7% after LSPSD. The functional outcome scores, back pain, and claudication pain in the immediate period and at the end of 1 year are similar in both the techniques. More patients had better functional outcomes after conventional decompression than the LSPSD technique. On the basis of this study, the superiority of one technique compared with the other is not established, mandating the need for further long-term studies. 2.

  15. A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy

    PubMed Central

    Kirby, Anna M; Lee, Steven F; Bartlett, Freddie; Titmarsh, Kumud; Donovan, Ellen; Griffin, Clare L; Gothard, Lone; Locke, Imogen; McNair, Helen A

    2016-01-01

    Objective: The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. Methods: In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σsetup) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. Results: 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σsetup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. Conclusion: UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial. PMID:27710100

  16. A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy.

    PubMed

    Landeg, Steven J; Kirby, Anna M; Lee, Steven F; Bartlett, Freddie; Titmarsh, Kumud; Donovan, Ellen; Griffin, Clare L; Gothard, Lone; Locke, Imogen; McNair, Helen A

    2016-12-01

    The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σ setup ) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σ setup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial.

  17. Evaluation of interactive teaching for undergraduate medical students using a classroom interactive response system in India.

    PubMed

    Datta, Rakesh; Datta, Karuna; Venkatesh, M D

    2015-07-01

    The classical didactic lecture has been the cornerstone of the theoretical undergraduate medical education. Their efficacy however reduces due to reduced interaction and short attention span of the students. It is hypothesized that the interactive response pad obviates some of these drawbacks. The aim of this study was to evaluate the effectiveness of an interactive response system by comparing it with conventional classroom teaching. A prospective comparative longitudinal study was conducted on 192 students who were exposed to either conventional or interactive teaching over 20 classes. Pre-test, Post-test and retentions test (post 8-12 weeks) scores were collated and statistically analysed. An independent observer measured number of student interactions in each class. Pre-test scores from both groups were similar (p = 0.71). There was significant improvement in both post test scores when compared to pre-test scores in either method (p < 0.001). The interactive post-test score was better than conventional post test score (p < 0.001) by 8-10% (95% CI-difference of means - 8.2%-9.24%-10.3%). The interactive retention test score was better than conventional retention test score (p < 0.001) by 15-18% (95% CI-difference of means - 15.0%-16.64%-18.2%). There were 51 participative events in the interactive group vs 25 in the conventional group. The Interactive Response Pad method was efficacious in teaching. Students taught with the interactive method were likely to score 8-10% higher (statistically significant) in the immediate post class time and 15-18% higher (statistically significant) after 8-12 weeks. The number of student-teacher interactions increases when using the interactive response pads.

  18. Facebook advertising for participant recruitment into a blood pressure clinical trial.

    PubMed

    Nash, Erin L; Gilroy, Deborah; Srikusalanukul, Wichat; Abhayaratna, Walter P; Stanton, Tony; Mitchell, Geoffrey; Stowasser, Michael; Sharman, James E

    2017-12-01

    Recruitment of sufficient sample size into clinical trials is challenging. Conventional advertising methods are expensive and are often ineffective. The effectiveness of Facebook for recruitment into blood pressure clinical trials of middle-to-older-aged people is unknown. This study aimed to assess this by comparing Facebook advertising with conventional recruitment methods from a retrospective analysis within a clinical trial. Conventional advertisements (newspaper, radio and posters) were employed for the first 20 months of a randomized controlled clinical trial conducted in three Australian capital cities from Tasmania, Queensland and the Australian Capital Territory. With dwindling participant recruitment, at 20 months a Facebook advertising campaign was employed intermittently over a 4-month period. Recruitment results were retrospectively compared with those using conventional methods in the previous 4 months. Compared with conventional recruitment methods, Facebook advertisement was associated with a significant increase in the number of participants recruited in the Australian Capital Territory (from an average 1.8-7.3/month; P < 0.05). There was also an increase in Tasmania that was of borderline significance (from 4.0 participants recruited/month to 9.3/month; P = 0.052). However, there was no effect in Queensland (from 6.0 participants recruited/month to 3.0/month; P = 0.15). Facebook advertisement was associated with a significant decrease in the age of participants enquiring into the study (from 60.9 to 58.7 years; P < 0.001). Facebook advertising was successful in helping to increase recruitment of middle-to-older aged participants into a blood pressure clinical trial, although there may be some variability in effect that is dependent on location.

  19. Evaluation of the physicochemical properties and compaction behavior of melt granules produced in microwave-induced and conventional melt granulation in a single pot high shear processor.

    PubMed

    Loh, Z H; Sia, B Y; Heng, Paul W S; Lee, C C; Liew, Celine V

    2011-12-01

    Recently, microwave-induced melt granulation was shown to be a promising alternative to conventional melt granulation with improved process monitoring capabilities. This study aimed to compare the physicochemical and compaction properties of granules produced from microwave-induced and conventional melt granulation. Powder admixtures comprising equivalent proportions by weight of lactose 200 M and anhydrous dicalcium phosphate were granulated with polyethylene glycol 3350 under the influence of microwave-induced and conventional heating in a 10-L single pot high shear processor. The properties of the granules and compacts produced from the two processes were compared. Relative to conventional melt granulation, the rates at which the irradiated powders heated up in microwave-induced melt granulation were lower. Agglomerate growth proceeded at a slower rate, and this necessitated longer massing durations for growth induction. These factors prompted greater evaporative moisture losses from the melt granules. Additionally, nonuniform heating of the powders under the influence of microwaves led to increased inter-batch variations in the binder contents of resultant melt granules and a reliance of content homogeneity on massing duration. Agglomerate growth proceeded more rapidly under the influence of conventional heating due to the enhanced heating capabilities of the powders. Melt granules produced using the conventional method possessed higher moisture contents and improved content homogeneity. The compaction behavior of melt granules were affected by their mean sizes, porosities, flow properties, binder, and moisture contents. The last two factors were responsible for the disparities in compaction behavior of melt granules produced from microwave-induced and conventional melt granulation.

  20. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    PubMed

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  1. Robotic Assistance Enables Inexperienced Surgeons to Perform Unicompartmental Knee Arthroplasties on Dry Bone Models with Accuracy Superior to Conventional Methods

    PubMed Central

    Masjedi, Milad; Andrews, Barry; Cobb, Justin

    2013-01-01

    Robotic systems have been shown to improve unicompartmental knee arthroplasty (UKA) component placement accuracy compared to conventional methods when used by experienced surgeons. We aimed to determine whether inexperienced UKA surgeons can position components accurately using robotic assistance when compared to conventional methods and to demonstrate the effect repetition has on accuracy. Sixteen surgeons were randomised to an active constraint robot or conventional group performing three UKAs over three weeks. Implanted component positions and orientations were compared to planned component positions in six degrees of freedom for both femoral and tibial components. Mean procedure time decreased for both robot (37.5 mins to 25.7 mins) (P = 0.002) and conventional (33.8 mins to 21.0 mins) (P = 0.002) groups by attempt three indicating the presence of a learning curve; however, neither group demonstrated changes in accuracy. Mean compound rotational and translational errors were lower in the robot group compared to the conventional group for both components at all attempts for which rotational error differences were significant at every attempt. The conventional group's positioning remained inaccurate even with repeated attempts although procedure time improved. In comparison, by limiting inaccuracies inherent in conventional equipment, robotic assistance enabled surgeons to achieve precision and accuracy when positioning UKA components irrespective of their experience. PMID:23862069

  2. Investigation of nano lipid vesicles of methotrexate for anti-rheumatoid activity

    PubMed Central

    Prabhu, Prabhakara; Shetty, Rakshith; Koland, Marina; Vijayanarayana, K; Vijayalakshmi, KK; Nairy, M Harish; Nisha, GS

    2012-01-01

    Background The purpose of this study was to formulate and evaluate nano lipid vesicles of methotrexate (MTX) for its anti-rheumatoid activity. Methods In this study the principle of both active as well as passive targeting using MTX-loaded stealth liposomes as per the magic gun approach was followed. Stealth liposomes of MTX were prepared by thin-film hydration method using a PEGylated phospholipid-like DSPE-MPEG 2000. Similarly, conventional liposomes were prepared using phospholipids like DPPC and DSPC. Conventional liposomes were coated with a hydrophilic biocompatible polymer like chitosan. They were investigated for their physical properties and in vitro release profile. Further, in vivo screening of the formulations for their anti-rheumatoid efficacy was carried out in rats. Rheumatoid arthritis was induced in male Wistar-Lewis rats using complete Freund’s adjuvant (1 mg/mL Mycobacterium tuberculosis, heat killed in mineral oil). Results It was found that chitosan coating of the conventional liposomes increased the physical stability of the liposomal suspension as well as its entrapment efficiency. The size of the unsonicated lipid vesicles was found to be in the range of 8–10 μm, and the sonicated lipid vesicles in the range of 210–260 nm, with good polydispersity index. Further, chitosan-coated conventional liposomes and the PEGylated liposomes released the drug for a prolonged period of time, compared to the uncoated conventional liposomes. It was found that there was a significant reduction in edema volume in the rat group administered with the test stealth liposomal formulations and chitosan-coated conventional liposomes (PEGylated and chitosan-coated conventional) compared to that of the control and standard (administered with free MTX) group of rats. PEGylated liposomes showed almost equal efficacy as that of the chitosan-coated conventional liposomes. Conclusion Lipid nano vesicles of MTX can be administered by intravenous route, whereby the drug selectively reaches the target site with reduced toxicity to other organs. PMID:22275833

  3. Simplicity, safety, and acceptability of insulin pen use versus the conventional vial/syringe device in patients with type 1 and type 2 diabetes mellitus in Lebanon

    PubMed Central

    Ramadan, Wijdan H; Khreis, Noura A; Kabbara, Wissam K

    2015-01-01

    Background The aim of the study was to evaluate the simplicity, safety, patients’ preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes. Methods This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 months. Answers were entered into the Statistical Package for Social Sciences (SPSS) software and Excel spreadsheet. t-test, logistic regression analysis, and correlation analysis were used in order to analyze the results. Results A higher percentage of patients from the insulin pen users group (95.2%) found the method easy to use as compared to only 46.7% of the insulin conventional users group (P 0.001, relative risk [RR]: 2.041, 95% confidence interval [CI]: 1.178–3.535). Moreover, 61.9% and 26.7% of pen users and conventional users, respectively, could read the scale easily (P 0.037, RR 2.321, 95% CI: 0.940–5.731), while 85.7% of pen users found it more convenient shifting to pen and 86.7% of the conventional users would want to shift to pen if it had the same cost. Pain perception was statistically different between the groups. A much higher percentage (76.2%) of pen users showed no pain during injection compared to only 26.7% of conventional users (P 0.003, RR 2.857, 95% CI: 1.194–6.838). Conclusion The insulin pen was significantly much easier to use and less painful than the conventional vial/syringe. Proper education on the methods of administration/storage and disposal of needles/syringes is needed in both groups. PMID:25848231

  4. Paresthesia-Free High-Density Spinal Cord Stimulation for Postlaminectomy Syndrome in a Prescreened Population: A Prospective Case Series.

    PubMed

    Sweet, Jennifer; Badjatiya, Anish; Tan, Daniel; Miller, Jonathan

    2016-04-01

    Spinal cord stimulation (SCS) traditionally is thought to require paresthesia, but there is evidence that paresthesia-free stimulation using high-density (HD) parameters might also be effective. The purpose of this study is to evaluate relative effectiveness of conventional, subthreshold HD, and sham stimulation on pain intensity and quality of life. Fifteen patients with response to conventional stimulation (60 Hz/350 μsec) were screened with a one-week trial of subthreshold HD (1200 Hz/200 μsec/amplitude 90% paresthesia threshold) and enrolled if there was at least 50% reduction on visual analog scale (VAS) for pain. Subjects were randomized into two groups and treated with four two-week periods of conventional, subthreshold HD, and sham stimulation in a randomized crossover design. Four of 15 patients responded to subthreshold HD stimulation. Mean VAS during conventional, subthreshold HD, and sham stimulation was 5.32 ± 0.63, 2.29 ± 0.41, and 6.31 ± 1.22, respectively. There was a significant difference in pain scores during the blinded crossover study of subthreshold HD vs. sham stimulation (p < 0.05, Student's t-test). Post hoc analysis revealed that subjects reported significantly greater attention to pain during conventional stimulation compared with subthreshold HD stimulation (p < 0.05, Student's t-test). All subjects reported a positive impression of change for subthreshold HD stimulation compared with conventional stimulation, and there was a trend toward greater likelihood for response to subthreshold HD stimulation in comparison with sham stimulation (p = 0.07, Fisher's exact test). At the end of the trial, all subjects elected to continue to receive subthreshold HD stimulation rather than conventional stimulation. Paresthesia are not necessary for pain relief using commercially available SCS devices, and may actually increase attention to pain. Subthreshold HD SCS represents a viable alternative to conventional stimulation among patients who are confirmed to have a clinical response to it. © 2015 International Neuromodulation Society.

  5. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia

    PubMed Central

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H.; Wan Mohamed Radzi, Che W. J.; Thung, Tze-Young; Premarathne, Jayasekara M. K. J. K.; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B.; Mohd Fadzil, Siti N.; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count (P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S. Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S. Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S. Typhimurium, and S. Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to appropriate post-harvest handling practices from farm to fork to ensure the quality and safety of the fresh produce. PMID:28824567

  6. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia.

    PubMed

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H; Wan Mohamed Radzi, Che W J; Thung, Tze-Young; Premarathne, Jayasekara M K J K; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B; Mohd Fadzil, Siti N; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count ( P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S . Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S . Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S . Typhimurium, and S . Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to appropriate post-harvest handling practices from farm to fork to ensure the quality and safety of the fresh produce.

  7. Comparative Effectiveness of Homoeopathic vs. Conventional Therapy in Usual Care of Atopic Eczema in Children: Long-Term Medical and Economic Outcomes

    PubMed Central

    Roll, Stephanie; Reinhold, Thomas; Pach, Daniel; Brinkhaus, Benno; Icke, Katja; Staab, Doris; Jäckel, Tanja; Wegscheider, Karl; Willich, Stefan N.; Witt, Claudia M.

    2013-01-01

    Background One in five children visiting a homeopathic physician suffers from atopic eczema. Objectives We aimed to examine the long-term effectiveness, safety and costs of homoeopathic vs. conventional treatment in usual medical care of children with atopic eczema. Methods In this prospective multi-centre comparative observational non-randomized rater-blinded study, 135 children (48 homoeopathy, 87 conventional) with mild to moderate atopic eczema were included by their respective physicians. Depending on the specialisation of the physician, the primary treatment was either standard conventional treatment or individualized homeopathy as delivered in routine medical care. The main outcome was the SCORAD (SCORing Atopic Dermatitis) at 36 months by a blinded rater. Further outcomes included quality of life, conventional medicine consumption, safety and disease related costs at six, 12 and 36 months after baseline. A multilevel ANCOVA was used, with physician as random effect and the following fixed effects: age, gender, baseline value, severity score, social class and parents’ expectation. Results The adjusted mean SCORAD showed no significant differences between the groups at 36 months (13.7 95% CI [7.9–19.5] vs. 14.9 [10.4–19.4], p = 0.741). The SCORAD response rates at 36 months were similar in both groups (33% response: homoeopathic 63.9% vs. conventional 64.5%, p = 0.94; 50% response: 52.0% vs. 52.3%, p = 0.974). Total costs were higher in the homoeopathic versus the conventional group (months 31–36 200.54 Euro [132.33–268.76] vs. 68.86 Euro [9.13–128.58], p = 0.005). Conclusions Taking patient preferences into account, while being unable to rule out residual confounding, in this long-term observational study, the effects of homoeopathic treatment were not superior to conventional treatment for children with mild to moderate atopic eczema, but involved higher costs. PMID:23383019

  8. Improved detection rates and treatment planning of head and neck cancer using dual-layer spectral CT.

    PubMed

    Lohöfer, Fabian K; Kaissis, Georgios A; Köster, Frances L; Ziegelmayer, Sebastian; Einspieler, Ingo; Gerngross, Carlos; Rasper, Michael; Noel, Peter B; Koerdt, Steffen; Fichter, Andreas; Rummeny, Ernst J; Braren, Rickmer F

    2018-05-28

    The aim of this study was to evaluate the advantages of dual-layer spectral CT (DLSCT) in detection and staging of head and neck cancer (HNC) as well as the imaging of tumour margins and infiltration depth compared to conventional contrast enhanced CT (CECT). Thirty-nine patients with a proven diagnosis of HNC were examined with a DLSCT scanner and retrospectively analysed. An age-matched healthy control group of the same size was used. Images were acquired in the venous phase. Virtual monoenergetic 40keV-equivalent (MonoE40) images were compared to CECT-images. Diagnostic confidence for tumour identification and margin detection was rated independently by four experienced observers. The steepness of the Hounsfield unit (HU)-increase at the tumour margin was analysed. External carotid artery branch image reconstructions were performed and their contrast compared to conventional arterial phase imaging. Means were compared using a Student's t-test. ANOVA was used for multiple comparisons. MonoE40 images were superior to CECT-images in tumour detection and margin delineation. MonoE40 showed significantly higher attenuation differences between tumour and healthy tissue compared to CECT-images (p < 0.001). The HU-increase at the boundary of the tumour was significantly steeper in MonoE40 images compared to CECT-images (p < 0.001). Iodine uptake in the tumour was significantly higher compared to healthy tissue (p < 0.001). MonoE40 compared to conventional images allowed visualisation of external carotid artery branches from the venous phase in a higher number of cases (87% vs. 67%). DLSCT enables improved detection of primary and recurrent head and neck cancer and quantification of tumour iodine uptake. Improved contrast of MonoE40 compared to conventional reconstructions enables higher diagnostic confidence concerning tumour margin detection and vessel identification. • Sensitivity concerning tumour detection are higher using dual-layer spectral-CT than conventional CT. • Lesion to background contrast in DLSCT is significantly higher than in CECT. • DLSCT provides sufficient contrast for evaluation of external carotid artery branches.

  9. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients

    PubMed Central

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-01-01

    Abstract Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests. Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed. The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values. Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients. PMID:27311005

  10. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients.

    PubMed

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-06-01

    Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests.Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed.The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values.Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients.

  11. Evaluation of heavy metal leaching from coal ash-versus conventional concrete monoliths and debris.

    PubMed

    Gwenzi, Willis; Mupatsi, Nyarai M

    2016-03-01

    Application of coal ash in construction materials is constrained by the potential risk of heavy metal leaching. Limited information is available on the comparative heavy metal leaching from coal ash-versus conventional concrete. The current study compared total and leached heavy metal concentrations in unbound coal ash, cement and sand; and investigated the effect of initial leachant pH on heavy metal leaching from coal-ash versus conventional concrete monoliths and their debris. Total Pb, Mn and Zn in coal ash were lower than or similar to that of other materials, while Cu and Fe showed the opposite trend. Leached concentrations of Zn, Pb, Mn, Cu and Fe in unbound coal ash, its concrete and debris were comparable and in some cases even lower than that for conventional concrete. In all cases, leached concentrations accounted for just <1% of the total concentrations. Log-log plots of concentration and cumulative release of Fe versus time based on tank leaching data showed that leaching was dominated by diffusion. Overall, the risk of Zn, Pb, Mn, Cu and Fe leaching from coal ash and its concrete was minimal and comparable to that of conventional concrete, a finding in contrast to widely held public perceptions and earlier results reported in other regions such as India. In the current study the coal ash, and its concrete and debris had highly alkaline pH indicative of high acid neutralizing and pH buffering capacity, which account for the stabilization of Zn, Pb, Mn, Cu and Fe. Based on the low risk of Zn, Pb, Mn, Cu and Fe leaching from the coal ash imply that such coal ash can be incorporated in construction materials such as concrete without adverse impacts on public and environmental health from these constituents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The use of conventional transcutaneous electrical nerve stimulation in chronic facial myalgia patients.

    PubMed

    De Giorgi, Ilaria; Castroflorio, Tommaso; Sartoris, Barbara; Deregibus, Andrea

    2017-01-01

    The aim of this study was to evaluate the efficacy of conventional TENS in women affected by chronic facial myalgia. The study was performed on 49 women affected by chronic facial myalgia randomly allocated in the TENS group (34 women) and the control group (15 women). The subjective level of pain was assessed by the Visual Analogue Scale indicating the mean (VAS MEAN), the maximum (VAS MAX) and the current intensity of pain (VAS NOW). The level of pain at the muscular palpation sites was assessed by the Pericranial Muscle Tenderness Score (PTS) and the Cervical Muscle Tenderness Score (CTS). The TENS therapy lasted for 10 weeks, and data were collected at baseline, after 5, 10, 15 and 25 weeks. The differences between groups before and after treatment were compared with the Mann-Whitney and the Kolmogorov-Smirnov tests. The intra-group differences were compared with the one-way ANOVA test. The results showed that the VAS MEAN, VAS MAX, PTS and CTS were significantly reduced in the TENS group compared to the control group after 10 weeks of TENS (p < 0.05). The intra-group analysis revealed a decreasing tendency of VAS MEAN, VAS MAX, VAS NOW, PTS and CTS in the TENS group in a 25-week period (p < 0.05). The study demonstrated the efficacy of conventional TENS in patients with chronic facial myalgia and the decrease in both subjective and objective pain. Conventional TENS is a safe, non-invasive, easy-to-administer therapy for chronic facial myalgia.

  13. Rationale for the tinnitus retraining therapy trial

    PubMed Central

    Formby, Craig; Scherer, Roberta

    2013-01-01

    The Tinnitus Retraining Therapy Trial (TRTT) is a National Institutes of Health-sponsored, multi-centered, placebo-controlled, randomized trial evaluating the efficacy of tinnitus retraining therapy (TRT) and its component parts, directive counseling and sound therapy, as treatments for subjective debilitating tinnitus in the military. The TRTT will enroll 228 individuals at an allocation ratio of 1:1:1 to: (1) directive counseling and sound therapy using conventional sound generators; (2) directive counseling and placebo sound generators; or (3) standard of care as administered in the military. Study centers include a Study Chair’s Office, a Data Coordinating Center, and six Military Clinical Centers with treatment and data collection standardized across all clinics. The primary outcome is change in Tinnitus Questionnaire (TQ) score assessed longitudinally at 3, 6, 12, and 18-month follow-up visits. Secondary outcomes include: Change in TQ sub-scales, Tinnitus Handicap Inventory, Tinnitus Functional Index, and TRT interview visual analog scale; audiometric and psychoacoustic measures; and change in quality of life. The TRTT will evaluate TRT efficacy by comparing TRT (directive counseling and conventional sound generators) with standard of care; directive counseling by comparing directive counseling plus placebo sound generators versus standard of care; and sound therapy by comparing conventional versus placebo sound generators. We hypothesize that full TRT will be more efficacious than standard of care, directive counseling and placebo sound generators more efficacious than standard of care, and conventional more efficacious than placebo sound generators in habituating the tinnitus awareness, annoyance, and impact on the study participant’s life. PMID:23571304

  14. New surgical approach for root coverage of localized gingival recession with acellular dermal matrix: a 12-month comparative clinical study.

    PubMed

    Barros, Raquel R M; Novaes, Arthur B; Grisi, Márcio F M; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B

    2005-01-01

    Acellular dermal matrix graft (ADMG) has been used as an advantageous substitute for autogenous subepithelial connective tissue graft (SCTG). However, the surgical techniques used were primarily developed for the SCTG, and they may not be adequate for ADMG since it has a different healing process than SCTG owing to its different vascular and cellular structures. This study compared the 1-year clinical outcome of a new surgical approach with the outcome of a conventional procedure for the treatment of localized gingival recessions, both performed using the ADMG. The clinical parameters-probing depth, relative clinical attachment level, gingival recession (GR), and width of keratinized tissue-of 32 bilateral Miller Class I or II gingival recessions were assessed at baseline and 12 months postoperatively. Significant clinical changes for both surgical techniques were achieved after this period, including GR reduction from 3.4 mm presurgery to 1.2 mm at 1 year for the conventional technique and from 3.9 mm presurgery to 0.7 mm at 1 year for the new technique. The percentage of root coverage was 62.3% and 82.5% for the conventional and new techniques, respectively. Comparisons between the groups after this period by Mann-Whitney rank sum test revealed statistically significant greater reduction of GR favoring the new procedure (p = .000). Based on the results of this study, it can be concluded that a new surgical technique using an ADMG is more suitable for root coverage when compared with the conventional technique. The results revealed a statistically significant improvement in clinical performance with the ADMG approach.

  15. A Randomized Trial of Phototherapy with Filtered Sunlight in African Neonates.

    PubMed

    Slusher, Tina M; Olusanya, Bolajoko O; Vreman, Hendrik J; Brearley, Ann M; Vaucher, Yvonne E; Lund, Troy C; Wong, Ronald J; Emokpae, Abieyuwa A; Stevenson, David K

    2015-09-17

    Sequelae of severe neonatal hyperbilirubinemia constitute a substantial disease burden in areas where effective conventional phototherapy is unavailable. We previously found that the use of filtered sunlight for the purpose of phototherapy is a safe and efficacious method for reducing total bilirubin. However, its relative safety and efficacy as compared with conventional phototherapy are unknown. We conducted a randomized, controlled noninferiority trial in which filtered sunlight was compared with conventional phototherapy for the treatment of hyperbilirubinemia in term and late-preterm neonates in a large, urban Nigerian maternity hospital. The primary end point was efficacy, which was defined as a rate of increase in total serum bilirubin of less than 0.2 mg per deciliter per hour for infants up to 72 hours of age or a decrease in total serum bilirubin for infants older than 72 hours of age who received at least 5 hours of phototherapy; we prespecified a noninferiority margin of 10% for the difference in efficacy rates between groups. The need for an exchange transfusion was a secondary end point. We also assessed safety, which was defined as the absence of the need to withdraw therapy because of hyperthermia, hypothermia, dehydration, or sunburn. We enrolled 447 infants and randomly assigned 224 to filtered sunlight and 223 to conventional phototherapy. Filtered sunlight was efficacious on 93% of treatment days that could be evaluated, as compared with 90% for conventional phototherapy, and had a higher mean level of irradiance (40 vs. 17 μW per square centimeter per nanometer, P<0.001). Temperatures higher than 38.0°C occurred in 5% of the infants receiving filtered sunlight and in 1% of those receiving conventional phototherapy (P<0.001), but no infant met the criteria for withdrawal from the study for reasons of safety or required an exchange transfusion. Filtered sunlight was noninferior to conventional phototherapy for the treatment of neonatal hyperbilirubinemia and did not result in any study withdrawals for reasons of safety. (Funded by the Thrasher Research Fund, Salt Lake City, and the National Center for Advancing Translational Sciences of the National Institutes of Health; Clinical Trials.gov number, NCT01434810.).

  16. A simplified and efficient method for the analysis of fatty acid methyl esters suitable for large clinical studies.

    PubMed

    Masood, Athar; Stark, Ken D; Salem, Norman

    2005-10-01

    Conventional sample preparation for fatty acid analysis is a complicated, multiple-step process, and gas chromatography (GC) analysis alone can require >1 h per sample to resolve fatty acid methyl esters (FAMEs). Fast GC analysis was adapted to human plasma FAME analysis using a modified polyethylene glycol column with smaller internal diameters, thinner stationary phase films, increased carrier gas linear velocity, and faster temperature ramping. Our results indicated that fast GC analyses were comparable to conventional GC in peak resolution. A conventional transesterification method based on Lepage and Roy was simplified to a one-step method with the elimination of the neutralization and centrifugation steps. A robotics-amenable method was also developed, with lower methylation temperatures and in an open-tube format using multiple reagent additions. The simplified methods produced results that were quantitatively similar and with similar coefficients of variation as compared with the original Lepage and Roy method. The present streamlined methodology is suitable for the direct fatty acid analysis of human plasma, is appropriate for research studies, and will facilitate large clinical trials and make possible population studies.

  17. Effect of two bakery products on short-term food intake and gut-hormones in young adults: a pilot study.

    PubMed

    Santaliestra-Pasías, A M; Garcia-Lacarte, M; Rico, M C; Aguilera, C M; Moreno, L A

    2015-08-01

    The aim of this study is to compare the effect of conventional bread and a whole grain bread on appetite and energy intake, satiety and satiety gut-hormones. A randomized controlled crossover pilot study was carried out in 11 university students (age: 18.7 ± 0.9 years; body mass index: 22.7 ± 2.7 kg/m(2)). Participants consumed two different mid-morning cereal-based snacks, including a conventional or whole grain bread. Two testing days were completed, including satiety questionnaires, blood sampling and consumption of standardized breakfast, mid-morning test-snacks and ad libitum lunch. Several gut-hormones were analysed and satiation was assessed using Visual Analogue Scale scores. The consumption of whole grain bread increased satiety perception, decreased the remained energy intake during the testing day, and decreased the postprandial response of peptide YY, compared with conventional bread (p < 0.005). These data suggest that the consumption of whole grain bread might be a useful strategy to improve satiety.

  18. Comparing the Efficacy of Low Dose and Conventional Dose of Oral Isotretinoin in Treatment of Moderate and Severe Acne Vulgaris

    PubMed Central

    Faghihi, Gita; Mokhtari, Fatemeh; Fard, Nasrin Motamedi; Motamedi, Narges; Hosseini, Sayed Mohsen

    2017-01-01

    Objective: This study was conducted to compare the effect of low-dose isotretinoin with its conventional dose in patients with moderate and severe acne. Methods: This was a clinical trial conducted on 60 male and female patients with moderate and severe acne vulgaris. The patients were divided into two treatment groups: 0.5 mg/kg/day isotretinoin capsule and low-dose isotretinoin capsule (0.25 mg/kg/day). Patients in both groups received 6-month treatment. At the end of the 6th month and 12th month (6 months after the end of the treatment), they were examined again, and their improvement was determined and compared. Findings: The average severity of acne in the two treatment groups did not differ significantly within any of the study periods. The most common side effects were nose dryness in the low-dose group (17%) and hair thinning and loss in the conventional-dose group (33.2%), although all the patients had dry lips. Conclusion: According to the same severity of the acne in two groups in different study periods, as well as fewer side effects and more patients' satisfaction, the low-dose isotretinoin can be considered in the treatment of acne. PMID:29417084

  19. Comparison of computer assisted surgery with conventional technique for treatment of abaxial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A

    2008-01-01

    To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.

  20. Does children's moral compass waver under social pressure? Using the conformity paradigm to test preschoolers' moral and social-conventional judgments.

    PubMed

    Kim, Elizabeth B; Chen, Chuansheng; Smetana, Judith G; Greenberger, Ellen

    2016-10-01

    The current study tested whether preschoolers' moral and social-conventional judgments change under social pressure using Asch's conformity paradigm. A sample of 132 preschoolers (Mage=3.83years, SD=0.85) rated the acceptability of moral and social-conventional events and also completed a visual judgment task (i.e., comparing line length) both independently and after having viewed two peers who consistently made immoral, unconventional, or visually inaccurate judgments. Results showed evidence of conformity on all three tasks, but conformity was stronger on the social-conventional task than on the moral and visual tasks. Older children were less susceptible to pressure for social conformity for the moral and visual tasks but not for the conventional task. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Modeling the Relative GHG Emissions of Conventional and Shale Gas Production

    PubMed Central

    2011-01-01

    Recent reports show growing reserves of unconventional gas are available and that there is an appetite from policy makers, industry, and others to better understand the GHG impact of exploiting reserves such as shale gas. There is little publicly available data comparing unconventional and conventional gas production. Existing studies rely on national inventories, but it is not generally possible to separate emissions from unconventional and conventional sources within these totals. Even if unconventional and conventional sites had been listed separately, it would not be possible to eliminate site-specific factors to compare gas production methods on an equal footing. To address this difficulty, the emissions of gas production have instead been modeled. In this way, parameters common to both methods of production can be held constant, while allowing those parameters which differentiate unconventional gas and conventional gas production to vary. The results are placed into the context of power generation, to give a ″well-to-wire″ (WtW) intensity. It was estimated that shale gas typically has a WtW emissions intensity about 1.8–2.4% higher than conventional gas, arising mainly from higher methane releases in well completion. Even using extreme assumptions, it was found that WtW emissions from shale gas need be no more than 15% higher than conventional gas if flaring or recovery measures are used. In all cases considered, the WtW emissions of shale gas powergen are significantly lower than those of coal. PMID:22085088

  2. Modeling the relative GHG emissions of conventional and shale gas production.

    PubMed

    Stephenson, Trevor; Valle, Jose Eduardo; Riera-Palou, Xavier

    2011-12-15

    Recent reports show growing reserves of unconventional gas are available and that there is an appetite from policy makers, industry, and others to better understand the GHG impact of exploiting reserves such as shale gas. There is little publicly available data comparing unconventional and conventional gas production. Existing studies rely on national inventories, but it is not generally possible to separate emissions from unconventional and conventional sources within these totals. Even if unconventional and conventional sites had been listed separately, it would not be possible to eliminate site-specific factors to compare gas production methods on an equal footing. To address this difficulty, the emissions of gas production have instead been modeled. In this way, parameters common to both methods of production can be held constant, while allowing those parameters which differentiate unconventional gas and conventional gas production to vary. The results are placed into the context of power generation, to give a ″well-to-wire″ (WtW) intensity. It was estimated that shale gas typically has a WtW emissions intensity about 1.8-2.4% higher than conventional gas, arising mainly from higher methane releases in well completion. Even using extreme assumptions, it was found that WtW emissions from shale gas need be no more than 15% higher than conventional gas if flaring or recovery measures are used. In all cases considered, the WtW emissions of shale gas powergen are significantly lower than those of coal.

  3. A Systematic Review on Immediate Loading of Implants Used to Support Overdentures Opposed by Conventional Prostheses: Factors That Might Influence Clinical Outcomes.

    PubMed

    Zygogiannis, Kostas; Wismeijer, Daniel; Aartman, Irene Ha; Osman, Reham B

    2016-01-01

    Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of these protocols on survival rates as well as clinical and prosthodontic outcomes. Several electronic databases were searched for all relevant articles published from 1966 to June 2014. Only randomized controlled trials and prospective studies with a minimum follow-up of 12 months were selected. The primary outcomes of interest were the success and survival rates of the implants. Prosthodontic complications were also evaluated. Fourteen studies fulfilled the inclusion criteria. Of the studies identified, nine were randomized controlled trials and five were prospective studies. The mean follow-up period was 3 years or less for the vast majority of the studies. The reported survival and success rates were comparable to that of conventional loading for most of the included studies. No specific immediate loading protocol seemed to perform better in terms of clinical and prosthodontic outcomes. Immediate loading protocols of mandibular overdentures seem to be a viable alternative to conventional loading. It was not possible to recommend a specific treatment protocol related to the number, diameter of the implants, and attachment system used. Long-term, well-designed studies comparing different immediate loading modalities could help to establish a protocol that delivers the most clinically predictable, efficient, and cost-effective outcome for edentulous patients in need of implant overdentures.

  4. The Surprisingly Low Motivational Power of Future Rewards: Comparing Conventional Money-Based Measures of Discounting with Motivation-Based Measures

    ERIC Educational Resources Information Center

    Ebert, Jane E. J.

    2010-01-01

    Temporal discount rates are often poor predictors of behaviors that we expect will be motivated by the future. The current research suggests this may be because conventional discounting measures are poor measures of the motivational value of future rewards. In six studies, I develop motivation-based measures of the present value (PV) of future…

  5. The Critical Humanisms of Dorothy Dinnerstein and Immanuel Kant Employed for Responding to Gender Bias: A Study, and an Exercise, in Radical Critique

    ERIC Educational Resources Information Center

    Bynum, Gregory Lewis

    2011-01-01

    Two humanist, critical approaches--those of Dorothy Dinnerstein and Immanuel Kant--are summarized, compared, and employed to critique gender bias in science education. The value of Dinnerstein's approach lies in her way of seeing conventional "masculinity" and conventional "femininity" as developing in relation to each other from early childhood.…

  6. Enhanced planar perovskite solar cell efficiency and stability using a perovskite/PCBM heterojunction formed in one step.

    PubMed

    Zhou, Long; Chang, Jingjing; Liu, Ziye; Sun, Xu; Lin, Zhenhua; Chen, Dazheng; Zhang, Chunfu; Zhang, Jincheng; Hao, Yue

    2018-02-08

    Perovskite/PCBM heterojunctions are efficient for fabricating perovskite solar cells with high performance and long-term stability. In this study, an efficient perovskite/PCBM heterojunction was formed via conventional sequential deposition and one-step formation processes. Compared with conventional deposition, the one-step process was more facile, and produced a perovskite thin film of substantially improved quality due to fullerene passivation. Moreover, the resulting perovskite/PCBM heterojunction exhibited more efficient carrier transfer and extraction, and reduced carrier recombination. The perovskite solar cell device based on one-step perovskite/PCBM heterojunction formation exhibited a higher maximum PCE of 17.8% compared with that from the conventional method (13.7%). The device also showed exceptional stability, retaining 83% of initial PCE after 60 days of storage under ambient conditions.

  7. Virtual Reality Therapy for Adults Post-Stroke: A Systematic Review and Meta-Analysis Exploring Virtual Environments and Commercial Games in Therapy

    PubMed Central

    Lohse, Keith R.; Hilderman, Courtney G. E.; Cheung, Katharine L.; Tatla, Sandy; Van der Loos, H. F. Machiel

    2014-01-01

    Background The objective of this analysis was to systematically review the evidence for virtual reality (VR) therapy in an adult post-stroke population in both custom built virtual environments (VE) and commercially available gaming systems (CG). Methods MEDLINE, CINAHL, EMBASE, ERIC, PSYCInfo, DARE, PEDro, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews were systematically searched from the earliest available date until April 4, 2013. Controlled trials that compared VR to conventional therapy were included. Population criteria included adults (>18) post-stroke, excluding children, cerebral palsy, and other neurological disorders. Included studies were reported in English. Quality of studies was assessed with the Physiotherapy Evidence Database Scale (PEDro). Results Twenty-six studies met the inclusion criteria. For body function outcomes, there was a significant benefit of VR therapy compared to conventional therapy controls, G = 0.48, 95% CI = [0.27, 0.70], and no significant difference between VE and CG interventions (P = 0.38). For activity outcomes, there was a significant benefit of VR therapy, G = 0.58, 95% CI = [0.32, 0.85], and no significant difference between VE and CG interventions (P = 0.66). For participation outcomes, the overall effect size was G = 0.56, 95% CI = [0.02, 1.10]. All participation outcomes came from VE studies. Discussion VR rehabilitation moderately improves outcomes compared to conventional therapy in adults post-stroke. Current CG interventions have been too few and too small to assess potential benefits of CG. Future research in this area should aim to clearly define conventional therapy, report on participation measures, consider motivational components of therapy, and investigate commercially available systems in larger RCTs. Trial Registration Prospero CRD42013004338 PMID:24681826

  8. Virtual reality therapy for adults post-stroke: a systematic review and meta-analysis exploring virtual environments and commercial games in therapy.

    PubMed

    Lohse, Keith R; Hilderman, Courtney G E; Cheung, Katharine L; Tatla, Sandy; Van der Loos, H F Machiel

    2014-01-01

    The objective of this analysis was to systematically review the evidence for virtual reality (VR) therapy in an adult post-stroke population in both custom built virtual environments (VE) and commercially available gaming systems (CG). MEDLINE, CINAHL, EMBASE, ERIC, PSYCInfo, DARE, PEDro, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews were systematically searched from the earliest available date until April 4, 2013. Controlled trials that compared VR to conventional therapy were included. Population criteria included adults (>18) post-stroke, excluding children, cerebral palsy, and other neurological disorders. Included studies were reported in English. Quality of studies was assessed with the Physiotherapy Evidence Database Scale (PEDro). Twenty-six studies met the inclusion criteria. For body function outcomes, there was a significant benefit of VR therapy compared to conventional therapy controls, G = 0.48, 95% CI = [0.27, 0.70], and no significant difference between VE and CG interventions (P = 0.38). For activity outcomes, there was a significant benefit of VR therapy, G = 0.58, 95% CI = [0.32, 0.85], and no significant difference between VE and CG interventions (P = 0.66). For participation outcomes, the overall effect size was G = 0.56, 95% CI = [0.02, 1.10]. All participation outcomes came from VE studies. VR rehabilitation moderately improves outcomes compared to conventional therapy in adults post-stroke. Current CG interventions have been too few and too small to assess potential benefits of CG. Future research in this area should aim to clearly define conventional therapy, report on participation measures, consider motivational components of therapy, and investigate commercially available systems in larger RCTs. Prospero CRD42013004338.

  9. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    PubMed

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic nononcological perineal pain as compared with pulsed radiofrequency. The short-term follow-up period of only six weeks was a major drawback associated with this study. © 2018 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  10. Terminal illness and the increased mortality risk of conventional antipsychotics in observational studies: a systematic review.

    PubMed

    Luijendijk, Hendrika J; de Bruin, Niels C; Hulshof, Tessa A; Koolman, Xander

    2016-02-01

    Numerous large observational studies have shown an increased risk of mortality in elderly users of conventional antipsychotics. Health authorities have warned against use of these drugs. However, terminal illness is a potentially strong confounder of the observational findings. So, the objective of this study was to systematically assess whether terminal illness may have biased the observational association between conventional antipsychotics and risk of mortality in elderly patients. Studies were searched in PubMed, CINAHL, Embase, the references of selected studies and articles referring to selected studies (Web of Science). Inclusion criteria were (i) observational studies that estimated (ii) the risk of all-cause mortality in (iii) new elderly users of (iv) conventional antipsychotics compared with atypical antipsychotics or no use. Two investigators assessed the characteristics of the exposure and reference groups, main results, measured confounders and methods used to adjust for unmeasured confounders. We identified 21 studies. All studies were based on administrative medical and pharmaceutical databases. Sicker and older patients received conventional antipsychotics more often than new antipsychotics. The risk of dying was especially high in the first month of use, and when haloperidol was administered per injection or in high doses. Terminal illness was not measured in any study. Instrumental variables that were used were also confounded by terminal illness. We conclude that terminal illness has not been adjusted for in observational studies that reported an increased risk of mortality risk in elderly users of conventional antipsychotics. As the validity of the evidence is questionable, so is the warning based on it. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Using machine learning to assess covariate balance in matching studies.

    PubMed

    Linden, Ariel; Yarnold, Paul R

    2016-12-01

    In order to assess the effectiveness of matching approaches in observational studies, investigators typically present summary statistics for each observed pre-intervention covariate, with the objective of showing that matching reduces the difference in means (or proportions) between groups to as close to zero as possible. In this paper, we introduce a new approach to distinguish between study groups based on their distributions of the covariates using a machine-learning algorithm called optimal discriminant analysis (ODA). Assessing covariate balance using ODA as compared with the conventional method has several key advantages: the ability to ascertain how individuals self-select based on optimal (maximum-accuracy) cut-points on the covariates; the application to any variable metric and number of groups; its insensitivity to skewed data or outliers; and the use of accuracy measures that can be widely applied to all analyses. Moreover, ODA accepts analytic weights, thereby extending the assessment of covariate balance to any study design where weights are used for covariate adjustment. By comparing the two approaches using empirical data, we are able to demonstrate that using measures of classification accuracy as balance diagnostics produces highly consistent results to those obtained via the conventional approach (in our matched-pairs example, ODA revealed a weak statistically significant relationship not detected by the conventional approach). Thus, investigators should consider ODA as a robust complement, or perhaps alternative, to the conventional approach for assessing covariate balance in matching studies. © 2016 John Wiley & Sons, Ltd.

  12. Application of fermentation for isoflavone extraction from soy molasses

    NASA Astrophysics Data System (ADS)

    Duru, K. C.; Kovaleva, E. G.; Glukhareva, T. V.

    2017-09-01

    Extraction of isoflavones from soy products remains a major challenge for researchers. Different extraction techniques have been employed but the need to use a cheap green extraction technique remains the main focus. This study applied fermentation of soy molasses using Saccharomyces cerevisiae for extraction of isoflavones and compared this technique to the conventional extraction method. The aluminum chloride colorimetric method was used for the determination of total flavonoid content of extracts. The highest yield was observed from extraction using ethyl acetate after fermentation of soy molasses and the lowest one was given by the extract from conventional extraction method. The DPPH radical scavenging activities of the extracts were also compared. The extract obtained using ethyl acetate after fermentation showed the highest antioxidant activity (0.0269 meq), while extract from conventional extraction had the lowest antioxidant activity (0.0055 meq). The effect of time on daidzein yield was studied using HPLC standard addition method. Daidzein concentration was higher in extract obtained at t = 80 min (3.82 ± 0.11 mg of daidzein /g of extract) as compared to that obtained at t = 60 min (2.89 ± 0.10 mg of daidzein /g of extract).

  13. Effects of trunk-hip strengthening on standing in children with spastic diplegia: a comparative pilot study.

    PubMed

    Kim, Joong-Hwi; Seo, Hye-Jung

    2015-05-01

    [Purpose] This study evaluated the effects of trunk-hip strengthening exercise on trunk-hip activation and pelvic tilt motion during standing in children with spastic diplegia and compared the improvement of pelvic tilt between the modified trunk-hip strengthening exercise and conventional exercise. [Subjects and Methods] Ten ambulant children with spastic diplegia were randomized to the modified trunk-hip strengthening exercise (n = 5) or conventional exercise (n = 5) group. The intervention consisted of a 6-week modified trunk-hip strengthening exercise 3 times per week. The children were tested for trunk-hip muscles activation and pelvic tilt motion during standing by surface electromyography and an inclinometer before and after the intervention. [Results] The anterior pelvic tilt angle and activation of the extensor spinae, rectus femoris, and semitendinosus during standing decreased significantly in the modified exercise group. The activation of extensor spinae differed significantly between groups. [Conclusion] Compared to the conventional exercise, the modified exercise was more effective for trunk-hip activation improvement and anterior pelvic tilt motion decrease during standing in children with spastic diplegia. We suggest clinicians use an individually tailored modified trunk-hip strengthening exercise for strengthening the weakest muscle groups in children with standing ability problems.

  14. Ergonomic design and evaluation of the handle for an endoscopic dissector.

    PubMed

    Shimomura, Yoshihiro; Minowa, Keita; Kawahira, Hiroshi; Katsuura, Tetsuo

    2016-05-01

    The purpose of this study was to design an endoscopic dissector handle and objectively assess its usability. The handles were designed with increased contact area between the fingers and thumb and the eye rings, and the eye rings were modified to have a more perpendicular insertion angle to the finger midline. Four different handle models were compared, including a conventional product. Subjects performed dissection, exclusion, grasping, precision manipulation and precision handling tasks. Electromyography and subjective evaluations were measured. Compared to conventional handles, the designated handle reduced the muscle load in the extensor and flexor muscles of the forearm and increased subjective stability. The activity of the first dorsal interosseous muscle was sometimes influenced by the shape of the other parts. The ergonomically designed endoscopic dissector handle used in this study achieved high usability. Medical instrument designs based on ergonomic concepts should be assessed with objective indices. Practitioner Summary: The endoscopic dissector handles were designed with increased contact area and more suitable insertion angle between the fingers and thumb and the eye rings. Compared to conventional handles, the designated handle reduced the muscle load in the extensor and flexor muscles of the forearm and increased subjective stability.

  15. An experiment-based comparative study of fuzzy logic control

    NASA Technical Reports Server (NTRS)

    Berenji, Hamid R.; Chen, Yung-Yaw; Lee, Chuen-Chein; Murugesan, S.; Jang, Jyh-Shing

    1989-01-01

    An approach is presented to the control of a dynamic physical system through the use of approximate reasoning. The approach has been implemented in a program named POLE, and the authors have successfully built a prototype hardware system to solve the cartpole balancing problem in real-time. The approach provides a complementary alternative to the conventional analytical control methodology and is of substantial use when a precise mathematical model of the process being controlled is not available. A set of criteria for comparing controllers based on approximate reasoning and those based on conventional control schemes is furnished.

  16. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.

    PubMed

    Pasha, Azam; Vishwakarma, Swati; Narayan, Anjali; Vinay, K; Shetty, Smitha V; Roy, Partha Pratim

    2015-09-01

    Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket produced lesser friction than the conventional metal bracket; but not less than the ceramic metal slot bracket. Ceramic SLB produced lesser friction when compared with the Clarity Advanced bracket with UEL, but the metal SLB produced the least friction among all the groups and subgroups. The present study concluded that the SS SLB produced least friction among all groups. Using the archwire and ligation method, frictional forces observed in the Clarity Advanced bracket and the conventional ceramic with metal slot bracket were almost similar; but the least resistance was determined in SS CB using both the ligation (CEL and UEL) system.

  17. Preformed crowns for decayed primary molar teeth.

    PubMed

    Innes, Nicola P T; Ricketts, David; Chong, Lee Yee; Keightley, Alexander J; Lamont, Thomas; Santamaria, Ruth M

    2015-12-31

    Crowns for primary molars are preformed and come in a variety of sizes and materials to be placed over decayed or developmentally defective teeth. They can be made completely of stainless steel (know as 'preformed metal crowns' or PMCs), or to give better aesthetics, may be made of stainless steel with a white veneer cover or made wholly of a white ceramic material. In most cases, teeth are trimmed for the crowns to be fitted conventionally using a local anaesthetic. However, in the case of the Hall Technique, PMCs are pushed over the tooth with no local anaesthetic, carious tissue removal or tooth preparation. Crowns are recommended for restoring primary molar teeth that have had a pulp treatment, are very decayed or are badly broken down. However, few dental practitioners use them in clinical practice. This review updates the original review published in 2007. Primary objectiveTo evaluate the clinical effectiveness and safety of all types of preformed crowns for restoring primary teeth compared with conventional filling materials (such as amalgam, composite, glass ionomer, resin modified glass ionomer and compomers), other types of crowns or methods of crown placement, non-restorative caries treatment or no treatment. Secondary objectiveTo explore whether the extent of decay has an effect on the clinical outcome of primary teeth restored with all types of preformed crowns compared with those restored with conventional filling materials. We searched the following electronic databases: Cochrane Oral Health Group Trials Register (to 21 January 2015), Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, 2014, Issue 12), MEDLINE via Ovid (1946 to 21 January 2015) and EMBASE via Ovid (1980 to 21 January 2015). We searched the US National Institutes of Health Trials Register (http://clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing trials and Open Grey for grey literature (to 21 January 2015). No restrictions were placed on the language or date of publication when searching the databases. Randomised controlled trials (RCTs) that assessed the effectiveness of crowns compared with fillings, other types of crowns, non-restorative approaches or no treatment in children with untreated tooth decay in one or more primary molar teeth. We would also have included trials comparing different methods of fitting crowns.For trials to be considered for this review, the success or failure of the interventions and other clinical outcomes had to be reported at least six months after intervention (with the exception of 'pain/discomfort during treatment and immediately postoperatively'). Two review authors independently assessed the title and abstracts for each article from the search results. and independently assessed the full text for each potentially relevant study. At least two authors assessed risk of bias and extracted data using a piloted data extraction form. We included five studies that evaluated three comparisons. Four studies compared crowns with fillings; two of them compared conventional PMCs with open sandwich restorations, and two compared PMCs fitted using the Hall Technique with fillings. One of these studies included a third arm, which allowed the comparison of PMCs (fitted using the Hall Technique) versus non-restorative caries treatment. In the two studies using crowns fitted using the conventional method, all teeth had undergone pulpotomy prior to the crown being placed. The final study compared two different types of crowns: PMCs versus aesthetic stainless steel crowns with white veneers. No RCT evidence was found that compared different methods of fitting preformed metal crowns (i.e. Hall Technique versus conventional technique).We considered outcomes reported at the dental appointment or within 24 hours of it, and in the short term (less than 12 months) or long term (12 months or more). Some of our outcomes of interest were not measured in the studies: time to restoration failure or retreatment, patient satisfaction and costs. Crowns versus fillingsAll studies in this comparison used PMCs. One study reported outcomes in the short term and found no reports of major failure or pain in either group. There was moderate quality evidence that the risk of major failure was lower in the crowns group in the long term (risk ratio (RR) 0.18, 95% confidence interval (CI) 0.06 to 0.56; 346 teeth in three studies, one conventional and two using Hall Technique). Similarly, there was moderate quality evidence that the risk of pain was lower in the long term for the crown group (RR 0.15, 95% CI 0.04 to 0.67; 312 teeth in two studies).Discomfort associated with the procedure was lower for crowns fitted using the Hall Technique than for fillings (RR 0.56, 95% CI 0.36 to 0.87; 381 teeth) (moderate quality evidence).It is uncertain whether there is a clinically important difference in the risk of gingival bleeding when using crowns rather than fillings, either in the short term (RR 1.69, 95% CI 0.61 to 4.66; 226 teeth) or long term (RR 1.74, 95% CI 0.99 to 3.06; 195 teeth, two studies using PMCs with conventional technique at 12 months) (low quality evidence). Crowns versus non-restorative caries treatmentOnly one study compared PMCs (fitted with the Hall Technique) with non-restorative caries treatment; the evidence quality was very low and we are therefore we are uncertain about the estimates. Metal crowns versus aesthetic crownsOne split-mouth study (11 participants) compared PMCs versus aesthetic crowns (stainless steel with white veneers). It provided very low quality evidence so no conclusions could be drawn. Crowns placed on primary molar teeth with carious lesions, or following pulp treatment, are likely to reduce the risk of major failure or pain in the long term compared to fillings. Crowns fitted using the Hall Technique may reduce discomfort at the time of treatment compared to fillings. The amount and quality of evidence for crowns compared to non-restorative caries, and for metal compared with aesthetic crowns, is very low. There are no RCTs comparing crowns fitted conventionally versus using the Hall Technique.

  18. Budesonide for induction of remission in Crohn's disease.

    PubMed

    Rezaie, Ali; Kuenzig, M Ellen; Benchimol, Eric I; Griffiths, Anne Marie; Otley, Anthony R; Steinhart, A Hillary; Kaplan, Gilaad G; Seow, Cynthia H

    2015-06-03

    Corticosteroids are commonly used for the induction of remission in Crohn's disease. However, traditional corticosteroids can cause significant adverse events. Budesonide is an alternative glucocorticoid with limited systemic bioavailability. The primary objective was to evaluate the efficacy and safety of oral budesonide for the induction of remission in Crohn's disease. The following electronic databases were searched up to June 2014: MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane IBD/FBD Group Specialised Trial Register, and ClinicalTrials.gov. Reference lists of articles, as well as conference proceedings were manually searched. Randomised controlled trials comparing budesonide to a placebo or active comparator were considered for inclusion. Two independent investigators reviewed studies for eligibility, extracted the data and assessed study quality. Methodological quality was assessed using the Cochrane risk of bias tool The overall quality of the evidence supporting the outcomes was evaluated using the GRADE criteria. Meta-analysis was performed using RevMan 5.3.5 software. The primary outcome was induction of remission (defined by a Crohn's disease activity index (CDAI) < 150) by week 8 to 16 of treatment. Secondary outcomes included: time to remission, mean change in CDAI, clinical, histological or endoscopic improvement, improvement in quality of life, adverse events and early withdrawal. We calculated the relative risk (RR) and corresponding 95% confidence intervals (CIs) for each dichotomous outcome and the mean difference and corresponding 95% CI for each continuous outcome. Data were analyzed on an intention-to-treat basis. A random-effects model was used for the pooled analyses. The overall quality of the evidence supporting the primary outcomes and selected secondary outcomes was evaluated using the GRADE criteria. Fourteen studies (1805 patients) were included: Nine (779 patients) compared budesonide to conventional corticosteroids, three (535 patients) were placebo-controlled, and two (491 patients) compared budesonide to mesalamine. Ten studies were judged to be at low risk of bias. Three studies were judged to be at high risk of bias due to open label design. One study was judged to be at high risk of bias due to selective reporting. After eight weeks of treatment, 9 mg budesonide was significantly more effective than placebo for induction of clinical remission. Forty-seven per cent (115/246) of budesonide patients achieved remission at 8 weeks compared to 22% (29/133) of placebo patients (RR 1.93, 95% CI 1.37 to 2.73; 3 studies, 379 patients). A GRADE analysis indicated that the overall quality of the evidence for this outcome was moderate due to sparse data (144 events). Budesonide was significantly less effective than conventional steroids for induction of remission at eight weeks. Fifty-two per cent of budesonide patients achieved remission at week 8 compared to 61% of patients who received conventional steroids (RR 0.85, 95% CI 0.75 to 0.97; 8 studies, 750 patients). A GRADE analysis indicated that the overall quality of the evidence for this outcome was moderate due to risk of bias. Budesonide was significantly less effective than conventional steroids among patients with severe disease (CDAI > 300) (RR 0.52, 95% CI 0.28 to 0.95). Studies comparing budesonide to mesalamine were not pooled due to heterogeneity (I(2) = 81%). One study (n = 182) found budesonide to be superior to mesalamine for induction of remission at 8 weeks. Sixty-eight per cent (63/93) of budesonide patients were in remission at 8 weeks compared to 42% (37/89) of mesalamine patients (RR 1.63, 95% CI 1.23 to 2.16). The other study found no statistically significant difference in remission rates at eight weeks. Sixty-nine per cent (107/154) of budesonide patients were in remission at 8 weeks compared to 62% (132/242) of mesalamine patients (RR 1.12, 95% CI 0.95 to 1.32). Fewer adverse events occurred in those treated with budesonide compared to conventional steroids (RR 0.64, 95% CI 0.54 to 0.76) and budesonide was better than conventional steroids in preserving adrenal function (RR for abnormal ACTH test 0.65, 95% CI 0.55 to 0.78). Budesonide is more effective than placebo for induction of remission in Crohn's disease. Although short-term efficacy with budesonide is less than with conventional steroids, particularly in those with severe disease or more extensive colonic involvement, the likelihood of adverse events and adrenal suppression with budesonide is lower. The current evidence does not allow for a firm conclusion on the relative efficacy of budesonide compared to 5-ASA products.

  19. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    PubMed

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in patient satisfaction between Groups 1 and 2 but it was significantly higher than that in Group3 (p < 0.05). Two and four mini dental implants can be immediately used successfully for retaining lower complete dentures, as shown after a 1-year follow up. © 2016 Wiley Periodicals, Inc.

  20. Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.

    PubMed

    Wang, Yongjun; Parker, Claire E; Bhanji, Tania; Feagan, Brian G; MacDonald, John K

    2016-04-21

    Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to July 9, 2015) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention-to-treat basis. Fifty-three studies (8548 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-one per cent of 5-ASA patients failed to enter clinical remission compared to 83% of placebo patients (RR 0.86, 95% CI 0.82 to 0.89). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-five per cent of once daily patients failed to enter clinical remission compared to 48% of conventionally dosed patients (RR 0.94, 95% CI 0.83 to 1.07). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Fifty per cent of patients in the 5-ASA group failed to enter remission compared to 52% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.02). A pooled analysis of 3 studies (n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. Common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.

  1. Six-month follow-up of isthmus-dependent right atrial flutter ablation using a remote magnetic catheter navigation system: a case-control study.

    PubMed

    Huo, Yan; Hindricks, Gerhard; Piorkowski, Christopher; Bollmann, Andreas; Wetzel, Ulrike; Sommer, Phillip; Gaspar, Thomas; Kottkamp, Hans; Arya, Arash

    2010-06-01

    The objective of this study was to compare results between the magnetic navigation system (MNS) and conventional catheter ablation of cavo-tricuspid isthmus (CTI)-dependent right atrial flutter (AFL) in a case control study. A remote MNS has been used for ablation of various arrhythmias including CTI-dependent AFL but comparative results between MNS and conventional ablation are not available. Between May and September 2007, a total of 51 consecutive patients (45 men, mean age 65.4 +/- 9.4 years) had undergone catheter ablation for CTI-dependent AFL. The catheter ablation (70 degrees C, 70 W, 90 s) was performed with either an 8-mm-tip magnetic catheter using MNS (case group, n = 26, 23 men, mean age 64.6 +/- 9.6 y) or a conventional 8-mm catheter (case group, n = 25, 22 men, mean age 65.4 +/- 9.1 y). Acute procedural success was defined as complete bidirectional isthmus block and success at six months was defined as absence of AFL during the six months follow-up. With respect to baseline characteristics there were no differences between the two groups. The procedure time in MNS and conventional group was [median (range)] 53 (30-130) min and 45 (30-100) min, respectively (P = 0.12). Acute success was achieved by MNS and conventional ablation in 25/26 (96.2%) and 25/25 (100%) of patients, respectively (P = 0.53). During the six months of follow-up 4 patients, 2 in each group, experienced recurrence (P = 0.90). No major complication occurred during the procedure. Charring on the catheter tip occurred in 5 patients (19.2%) in MNS and none of the patients in the control group (P <0.05). This case-control study demonstrated the acute and mid-term efficacy and safety of catheter ablation by MNS for CTI-dependent AFL, similar to rates achieved by conventional radiofrequency catheter ablation.

  2. A new method of sweat testing: the CF Quantum®sweat test.

    PubMed

    Rock, Michael J; Makholm, Linda; Eickhoff, Jens

    2014-09-01

    Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  3. Animal Board Invited Review: Comparing conventional and organic livestock production systems on different aspects of sustainability.

    PubMed

    van Wagenberg, C P A; de Haas, Y; Hogeveen, H; van Krimpen, M M; Meuwissen, M P M; van Middelaar, C E; Rodenburg, T B

    2017-10-01

    To sustainably contribute to food security of a growing and richer world population, livestock production systems are challenged to increase production levels while reducing environmental impact, being economically viable, and socially responsible. Knowledge about the sustainability performance of current livestock production systems may help to formulate strategies for future systems. Our study provides a systematic overview of differences between conventional and organic livestock production systems on a broad range of sustainability aspects and animal species available in peer-reviewed literature. Systems were compared on economy, productivity, environmental impact, animal welfare and public health. The review was limited to dairy cattle, beef cattle, pigs, broilers and laying hens, and to Europe, North America and New Zealand. Results per indicators are presented as in the articles without performing additional calculations. Out of 4171 initial search hits, 179 articles were analysed. Studies varied widely in indicators, research design, sample size and location and context. Quite some studies used small samples. No study analysed all aspects of sustainability simultaneously. Conventional systems had lower labour requirements per unit product, lower income risk per animal, higher production per animal per time unit, higher reproduction numbers, lower feed conversion ratio, lower land use, generally lower acidification and eutrophication potential per unit product, equal or better udder health for cows and equal or lower microbiological contamination. Organic systems had higher income per animal or full time employee, lower impact on biodiversity, lower eutrophication and acidification potential per unit land, equal or lower likelihood of antibiotic resistance in bacteria and higher beneficial fatty acid levels in cow milk. For most sustainability aspects, sometimes conventional and sometimes organic systems performed better, except for productivity, which was consistently higher in conventional systems. For many aspects and animal species, more data are needed to conclude on a difference between organic and conventional livestock production systems.

  4. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  5. Microleakage and penetration of a hydrophilic sealant and a conventional resin-based sealant as a function of preparation techniques: a laboratory study.

    PubMed

    Khogli, Ahmed Eltigani; Cauwels, Rita; Vercruysse, Chris; Verbeeck, Ronald; Martens, Luc

    2013-01-01

    Optimal pit and fissure sealing is determined by surface preparation techniques and choice of materials. This study aimed (i) to compare the microleakage and penetration depth of a hydrophilic sealant and a conventional resin-based sealant using one of the following preparation techniques: acid etching (AE) only, a diamond bur + AE, and Er:YAG laser combined with AE, and (ii) to evaluate the microleakage and penetration depth of the hydrophilic pit and fissure sealant on different surface conditions. Eighty recently extracted 3rd molars were randomly assigned to eight groups of ten teeth according to the material, preparation technique, and surface condition. For saliva contamination, 0.1 mL of fresh whole human saliva was used. All samples were submitted to 1000 thermal cycles and immersed in 2% methylene blue dye for 4 h. Sections were examined by a light microscope and analysed using image analysis software (Sigmascan(®)). The combination of Er:YAG + AE + conventional sealant showed the least microleakage. The sealing ability of the hydrophilic sealant was influenced by the surface condition. Er:YAG ablation significantly decreased the microleakage at the tooth-sealant interface compared to the non-invasive technique. The hydrophilic sealant applied on different surface conditions showed comparable result to the conventional resin-based sealant. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  6. Retrograde light-guided laryngoscopy for tracheal intubation: clinical practice and comparison with conventional direct laryngoscopy.

    PubMed

    Yang, Tao; Hou, Jiong; Li, Jinbao; Zhang, Xu; Zhu, Xiaoyan; Ni, Wen; Mao, Yanfei; Deng, Xiaoming

    2013-05-01

    Tracheal intubation with conventional laryngoscopy requires many trials until beginners are sufficiently skilled in intubating patients safely. To facilitate intubation, the authors used retrograde light-guided laryngoscopy (RLGL) and compared its feasibility with conventional direct laryngoscopy (DL). Twenty operators participated in a prospective, randomized, open-label, parallel-arm study. These operators intubated 205 patients randomly according to a computer-generated procedure by using either DL or RLGL (five intubations with each technique). The primary outcome was the success rate of tracheal intubation. The authors evaluated the success rate of tracheal intubation, the time to glottic exposure and tracheal intubation, and the Cormack and Lehane grades. Compared with DL, the success rate was greater in the RLGL group for all five intubations (72% vs. 47%; rate difference, 25%; 95% CI [11.84-38.16%], P < 0.001). This was associated with a shorter time to glottic exposure (median [25th and 75th percentile]; 27 [15; 42] vs. 45 [30; 73] s, P < 0.001), shorter intubation time (66 [44; 120] vs. 120 [69; 120] s, P < 0.001), and decreased throat soreness (mean ± SD; visual analog scale, 2.1 ± 0.9 vs. 3.7 ± 1.0 cm, P = 0.001) in the RLGL group compared to the DL group. RLGL is an alternative intubation technique. In our study, it enables beginners to intubate patients more successfully and quickly than conventional DL.

  7. [A comparative study between the Vitek YBC and Microscan Walk Away RYID automated systems with conventional phenotypic methods for the identification of yeasts of clinical interest].

    PubMed

    Ferrara, Giuseppe; Mercedes Panizol, Maria; Mazzone, Marja; Delia Pequeneze, Maria; Reviakina, Vera

    2014-12-01

    The aim of this study was to compare the identification of clin- ically relevant yeasts by the Vitek YBC and Microscan Walk Away RYID automated methods with conventional phenotypic methods. One hundred and ninety three yeast strains isolated from clinical samples and five controls strains were used. All the yeasts were identified by the automated methods previously mentioned and conventional phenotypic methods such as carbohydrate assimilation, visualization of microscopic morphology on corn meal agar and the use of chromogenic agar. Variables were assessed by 2 x 2 contingency tables, McNemar's Chi square, the Kappa index, and concordance values were calculated, as well as major and minor errors for the automated methods. Yeasts were divided into two groups: (1) frequent isolation and (2) rare isolation. The Vitek YBC and Microscan Walk Away RYID systems were concordant in 88.4 and 85.9% respectively, when compared to conventional phenotypic methods. Although both automated systems can be used for yeasts identification, the presence of major and minor errors indicates the possibility of misidentifications; therefore, the operator of this equipment must use in parallel, phenotypic tests such as visualization of microscopic morphology on corn meal agar and chromogenic agar, especially against infrequently isolated yeasts. Automated systems are a valuable tool; however, the expertise and judgment of the microbiologist are an important strength to ensure the quality of the results.

  8. Short-term effects of upper extremity circuit resistance training on muscle strength and functional independence in patients with paraplegia.

    PubMed

    Yildirim, Adem; Sürücü, Gülseren Dost; Karamercan, Ayşe; Gedik, Dilay Eken; Atci, Nermin; Dülgeroǧlu, Deniz; Özgirgin, Neşe

    2016-11-21

    A number of exercises to strengthen the upper extremities are recommended to increase functional independence and quality of life (QoL) in patients with paraplegia. Circuit resistance training (CRT) is a type of progressive resistive exercise performed repeatedly at fixed mechanical exercise stations. The aim of this study was to investigate the potential benefits of CRT for upper extremity muscle strength, functional independence, and QoL in patients with paraplegia. Twenty-six patients with paraplegia who were participating in a conventional rehabilitation program at a tertiary education and research hospital were enrolled in this study. The participants were randomly assigned to two groups. The exercise group participated in the CRT program, which consisted of repetitive exercises for the upper extremities performed at fixed mechanical stations 5 sessions per week for 6 weeks, in addition to conventional rehabilitation. Participants in the control group received only conventional rehabilitation over the same period. We compared the groups with respect to QoL, as well as isokinetic muscle test outcomes in the upper extremities, using the Functional Independence Measure (FIM) and Borg's scale. We observed significant increases in scores on the physical component of the FIM, Borg's scale, and QoL in both the exercise and control groups. Furthermore, the large majority of isokinetic values were significantly more improved in the exercise group compared to the control group. When post-treatment outcomes were compared between the groups, improvements in scores on the physical component of the FIM and in most isokinetic values were significantly greater in the exercise group. This study showed that CRT has positive effects on muscle strength in the upper extremities and the physical disability components of the FIM when added to conventional rehabilitation programs for paraplegic patients. However, we observed no significant improvement in QoL scores after adding CRT to a conventional treatment regime. Randomized trial (Level II).

  9. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  10. Frequency of unsatisfactory cervical cytology smears in cancer screening of Japanese women: A systematic review and meta-analysis.

    PubMed

    Hosono, Satoyo; Terasawa, Teruhiko; Katayama, Takafumi; Sasaki, Seiju; Hoshi, Keika; Hamashima, Chisato

    2018-04-01

    The Bethesda system (TBS) has been used for cervical cytological diagnosis in Japan since 2008. Evaluation of specimen adequacy is the most important aspect of quality assurance and for precise diagnosis in TBS. A systematic review and meta-analysis were carried out to assess the unsatisfactory specimen rate in the primary cervical cancer screening setting in Japan. Ovid Medline and Ichushi-Web databases were searched from inception through to May 2017. Prospective and retrospective studies that reported the proportion of unsatisfactory specimens in healthy asymptomatic Japanese women in a cervical cancer screening program were eligible for inclusion; 17 studies were included in the meta-analysis. The random-effects model meta-analysis calculated summary estimates of the unsatisfactory rate of 0.60% (95% confidence interval [CI], 0.18-1.96%; I 2 = 99%) for conventional cytology and 0.04% (95% CI, 0.00-0.35%; I 2 = 99%) for liquid-based cytology (LBC). However, comparative results between conventional and liquid-based cytology, based on four direct and nine comparative studies, showed no significant difference (summary odds ratio = 3.5 × 10 -2 favoring LBC [95% CI, 6.9 × 10 -4 -1.7]; I 2 = 98%). In the subgroup analyses and meta-regressions, use of non-cotton devices for conventional cytology and use of a particular platform for LBC were associated with lower unsatisfactory rates. Meta-regression also suggested chronological improvement in unsatisfactory rates for both tests. In Japanese cervical cancer screening programs, conventional cytology remains prevalent. Future research needs to focus on evaluating the impact of screening programs using LBC by comparing the accuracy, performance, and cost-effectiveness with conventional cytology in the Japanese population. © 2018 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  11. Effectiveness of Video Demonstration over Conventional Methods in Teaching Osteology in Anatomy.

    PubMed

    Viswasom, Angela A; Jobby, Abraham

    2017-02-01

    Technology and its applications are the most happening things in the world. So, is it in the field of medical education. This study was an evaluation of whether the conventional methods can compete with the test of technology. A comparative study of traditional method of teaching osteology in human anatomy with an innovative visual aided method. The study was conducted on 94 students admitted to MBBS 2014 to 2015 batch of Travancore Medical College. The students were divided into two academically validated groups. They were taught using conventional and video demonstrational techniques in a systematic manner. Post evaluation tests were conducted. Analysis of the mark pattern revealed that the group taught using traditional method scored better when compared to the visual aided method. Feedback analysis showed that, the students were able to identify bony features better with clear visualisation and three dimensional view when taught using the video demonstration method. The students identified visual aided method as the more interesting one for learning which helped them in applying the knowledge gained. In most of the questions asked, the two methods of teaching were found to be comparable on the same scale. As the study ends, we discover that, no new technique can be substituted for time tested techniques of teaching and learning. The ideal method would be incorporating newer multimedia techniques into traditional classes.

  12. General anesthesia versus segmental thoracic or conventional lumbar spinal anesthesia for patients undergoing laparoscopic cholecystectomy.

    PubMed

    Yousef, Gamal T; Lasheen, Ahmed E

    2012-01-01

    Laparoscopic cholecystectomy became the standard surgery for gallstone disease because of causing less postoperative pain, respiratory compromise and early ambulation. This study was designed to compare spinal anesthesia, (segmental thoracic or conventional lumbar) vs the gold standard general anesthesia as three anesthetic techniques for healthy patients scheduled for elective laparoscopic cholecystectomy, evaluating intraoperative parameters, postoperative recovery and analgesia, complications as well as patient and surgeon satisfaction. A total of 90 patients undergoing elective laparoscopic cholecystectomy, between January 2010 and May 2011, were randomized into three equal groups to undergo laparoscopic cholecystectomy with low-pressure CO2 pneumoperitoneum under segmental thoracic (TSA group) or conventional lumbar (LSA group) spinal anesthesia or general anesthesia (GA group). To achieve a T3 sensory level we used (hyperbaric bupivacaine 15 mg, and fentanyl 25 mg at L2/L3) for LSAgroup, and (hyperbaric bupivacaine 7.5 mg, and fentanyl 25 mg at T10/T11) for TSAgroup. Propofol, fentanyl, atracurium, sevoflurane, and tracheal intubation were used for GA group. Intraoperative parameters, postoperative recovery and analgesia, complications as well as patient and surgeon satisfaction were compared between the three groups. All procedures were completed laparoscopically by the allocated method of anesthesia with no anesthetic conversions. The time for the blockade to reach T3 level, intraoperative hypotensive and bradycardic events and vasopressor use were significantly lower in (TSA group) than in (LSA group). Postoperative pain scores as assessed throughout any time, postoperative right shoulder pain and hospital stay was lower for both (TSA group) and (LSA group) compared with (GA group). The higher degree of patients satisfaction scores were recorded in patients under segmental TSA. The present study not only confirmed that both segmental TSA and conventional lumber spinal anesthesia (LSA) are safe and good alternatives to general anesthesia (GA) in healthy patients undergoing laparoscopic cholecystectomy but also showed better postoperative pain control of both spinal techniques when compared with general anesthesia. Segmental TSA provides better hemodynamic stability, lesser vasopressor use and early ambulation and discharge with higher degree of patient satisfaction making it excellent for day case surgery compared with conventional lumbar spinal anesthesia.

  13. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    PubMed Central

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza, Leopoldino

    2015-01-01

    OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. RESULTS: No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. CONCLUSION: No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored. PMID:25992985

  14. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets.

    PubMed

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza Filho, Leopoldino

    2015-01-01

    The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored.

  15. Extrapolation-Based References Improve Motion and Eddy-Current Correction of High B-Value DWI Data: Application in Parkinson's Disease Dementia.

    PubMed

    Nilsson, Markus; Szczepankiewicz, Filip; van Westen, Danielle; Hansson, Oskar

    2015-01-01

    Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.

  16. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review

    PubMed Central

    Longoni, Juliano N.; Lopes, Beatriz M.; Freires, Irlan A.; Dutra, Kamile L.; Franco, Ademir; Paranhos, Luiz R.

    2017-01-01

    Objective: The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. Material and methods: The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. Results: The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans, 2 studies showed less accumulation in self-ligating than in conventional brackets. Conclusion: Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient – such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity. PMID:29279684

  17. Use of buffy coat thick films in detecting malaria parasites in patients with negative conventional thick films.

    PubMed

    Duangdee, Chatnapa; Tangpukdee, Noppadon; Krudsood, Srivicha; Wilairatana, Polrat

    2012-04-01

    To determine the frequency of malaria parasite detection from the buffy coat blood films by using capillary tube in falciparum malaria patients with negative conventional thick films. Thirty six uncomplicated falciparum malaria patients confirmed by conventional thick and thin films were included in the study. The patients were treated with artemisinin combination therapy at Hospital for Tropical Diseases, Bangkok, Thailand for 28 day. Fingerpricks for conventional blood films were conducted every 6 hours until negative parasitemia, then daily fingerpricks for parasite checks were conducted until the patients were discharged from hospital. Blood samples were also concurrently collected in 3 heparinized capillary tubes at the same time of fingerpricks for conventional blood films when the prior parasitemia was negative on thin films and parasitemia was lower than 50 parasites/200 white blood cells by thick film. The first negative conventional thick films were compared with buffy coat thick films for parasite identification. Out of 36 patients with thick films showing negative for asexual forms of parasites, buffy coat films could detect remaining 10 patients (27.8%) with asexual forms of Plasmodium falciparum. The study shows that buffy coat thick films are useful and can detect malarial parasites in 27.8% of patients whose conventional thick films show negative parasitemia.

  18. Oral 5-aminosalicylic acid for induction of remission in ulcerative colitis.

    PubMed

    Feagan, Brian G; Macdonald, John K

    2012-10-17

    Oral 5-aminosalicylic acid (5-ASA) preparations were intended to avoid the adverse effects of sulfasalazine (SASP) while maintaining its therapeutic benefits. Previously, it was found that 5-ASA drugs in doses of at least 2 g/day, were more effective than placebo but no more effective than SASP for inducing remission in ulcerative colitis. This updated review includes more recent studies and evaluates the efficacy and safety of 5-ASA preparations used for the treatment of mild to moderately active ulcerative colitis. The primary objectives were to assess the efficacy, dose-responsiveness and safety of oral 5-ASA compared to placebo, SASP, or 5-ASA comparators for induction of remission in active ulcerative colitis. A secondary objective of this systematic review was to compare the efficacy and safety of once daily dosing of oral 5-ASA with conventional (two or three times daily) dosing regimens. A computer-assisted literature search for relevant studies (inception to January 20, 2012) was performed using MEDLINE, EMBASE and the Cochrane Library. Review articles and conference proceedings were also searched to identify additional studies. Studies were accepted for analysis if they were randomized controlled clinical trials of parallel design, with a minimum treatment duration of four weeks. Studies of oral 5-ASA therapy for treatment of patients with active ulcerative colitis compared with placebo, SASP or other formulations of 5-ASA were considered for inclusion. Studies that compared once daily 5-ASA treatment with conventional dosing of 5-ASA (two or three times daily) and 5-ASA dose ranging studies were also considered for inclusion. The outcomes of interest were the failure to induce global/clinical remission, global/clinical improvement, endoscopic remission, endoscopic improvement, adherence, adverse events, withdrawals due to adverse events, and withdrawals or exclusions after entry. Trials were separated into five comparison groups: 5-ASA versus placebo, 5-ASA versus sulfasalazine, once daily dosing versus conventional dosing, 5-ASA versus comparator 5-ASA, and 5-ASA dose-ranging. Placebo-controlled trials were subgrouped by dosage. SASP-controlled trials were subgrouped by 5-ASA/SASP mass ratios. Once daily versus conventional dosing studies were subgrouped by formulation. 5-ASA-controlled trials were subgrouped by common 5-ASA comparators (e.g. Asacol, Claversal, Salofalk and Pentasa). Dose-ranging studies were subgrouped by 5-ASA formulation. We calculated the relative risk (RR) and 95% confidence intervals (95% CI) for each outcome. Data were analyzed on an intention to treat basis. Forty-eight studies (7776 patients) were included. The majority of included studies were rated as low risk of bias. 5-ASA was significantly superior to placebo with regard to all measured outcome variables. Seventy-two per cent of 5-ASA patients failed to enter clinical remission compared to 85% of placebo patients (RR 0.86, 95% CI 0.81 to 0.91). A dose-response trend for 5-ASA was also observed. No statistically significant differences in efficacy were found between 5-ASA and SASP. Fifty-four per cent of 5-ASA patients failed to enter remission compared to 58% of SASP patients (RR 0.90, 95% CI 0.77 to 1.04). No statistically significant differences in efficacy or adherence were found between once daily and conventionally dosed 5-ASA. Forty-two per cent of once daily patients failed to enter clinical remission compared to 44% of conventionally dosed patients (RR 0.95, 95% CI 0.82 to 1.10). Eight per cent of patients dosed once daily failed to adhere to their medication regimen compared to 6% of conventionally dosed patients (RR 1.36, 95% CI 0.64 to 2.86). There does not appear to be any difference in efficacy among the various 5-ASA formulations. Forty-eight per cent of patients in the 5-ASA group failed to enter remission compared to 50% of patients in the 5-ASA comparator group (RR 0.94, 95% CI 0.86 to 1.03). A pooled analysis of the ASCEND (I, II and III, n = 1459 patients) studies found no statistically significant difference in clinical improvement between Asacol 4.8 g/day and 2.4 g/day used for the treatment of moderately active ulcerative colitis. Thirty-seven per cent of patients in the 4.8 g/day group failed to improve clinically compared to 41% of patients in the 2.4 g/day group (RR 0.89; 95% CI 0.78 to 1.01). Subgroup analysis indicated that patients with moderate disease may benefit from the higher dose of 4.8 g/day. One study compared (n = 123 patients) Pentasa 4 g/day to 2.25 g/day in patients with moderate disease. Twenty-five per cent of patients in the 4 g/day group failed to improve clinically compared to 57% of patients in the 2.25 g/day group (RR 0.44; 95% CI 0.27 to 0.71). A pooled analysis of two studies comparing MMX mesalamine 4.8 g/day to 2.4 g/day found no statistically significant difference in efficacy (RR 1.03, 95% CI 0.82 to 1.29). 5-ASA was generally safe and common adverse events included flatulence, abdominal pain, nausea, diarrhea, headache and worsening ulcerative colitis. There were no statistically significant differences in the incidence of adverse events between 5-ASA and placebo, once daily and conventionally dosed 5-ASA, 5-ASA and comparator 5-ASA formulation and 5-ASA dose ranging (high dose versus low dose) studies. SASP was not as well tolerated as 5-ASA. Twenty-nine percent of SASP patients experienced an adverse event compared to 15% of 5-ASA patients (RR 0.48, 95% CI 0.37 to 0.63). 5-ASA was superior to placebo and no more effective than SASP. Considering their relative costs, a clinical advantage to using oral 5-ASA in place of SASP appears unlikely. 5-ASA dosed once daily appears to be as efficacious and safe as conventionally dosed 5-ASA. Adherence does not appear to be enhanced by once daily dosing in the clinical trial setting. It is unknown if once daily dosing of 5-ASA improves adherence in a community-based setting. There do not appear to be any differences in efficacy or safety among the various 5-ASA formulations. A daily dosage of 2.4 g appears to be a safe and effective induction therapy for patients with mild to moderately active ulcerative colitis. Patients with moderate disease may benefit from an initial dose of 4.8 g/day.

  19. Systematic Review on the Effects of Serious Games and Wearable Technology Used in Rehabilitation of Patients With Traumatic Bone and Soft Tissue Injuries.

    PubMed

    Meijer, Henriëtte A; Graafland, Maurits; Goslings, J Carel; Schijven, Marlies P

    2017-11-11

    To assess the effects on functional outcomes and treatment adherence of wearable technology and serious games (ie, interactive computer applications with specific purposes useful in the "real world") currently used in physical rehabilitation of patients after traumatic bone and soft tissue injuries. PubMed, EMBASE, Cochrane Library, and Current Index to Nursing and Allied Health Literature were searched without publication date restrictions for the terms wearable, serious game, videogame or mobile application, and rehabilitation, exercise therapy, and physiotherapy. The search yielded 2704 eligible articles, which were screened by 2 independent reviewers. Studies comparing serious games to standard therapy were included. Methodology and results of the studies were critically appraised in conformity with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Twelve articles were included, all of which tested "off-the-shelf" games. No studies on "wearable-controlled" games or games specifically developed for rehabilitation could be included. Medical conditions included postoperative rehabilitation and acute traumatic injuries. All studies were of low to moderate quality. Only 2 studies found beneficial effects of serious games compared to conventional therapy. One of 3 studies reporting pain scores found beneficial effects of serious games compared to physiotherapy. One of 5 trials reporting treatment adherence found a statistically significant advantage in the game group compared to conventional physiotherapy. Because of heterogeneity in study design and outcome measures, pooling of data was not possible. Serious games seem a safe alternative or addition to conventional physiotherapy after traumatic bone and soft tissue injuries. Future research should determine their validity and effectiveness in rehabilitation therapy, next to their cost-effectiveness and effect on treatment adherence. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods.

    PubMed

    Jambi, Safa; Walsh, Tanya; Sandler, Jonathan; Benson, Philip E; Skeggs, Richard M; O'Brien, Kevin D

    2014-08-19

    The term anchorage in orthodontic treatment refers to methods of controlling unwanted tooth movement. This is provided either by anchor sites within the mouth, such as the teeth and the palate, or from outside the mouth (headgear). Recently, new methods of providing anchorage have been developed using orthodontic implants which are surgically inserted into the bone in the mouth. This is termed surgical anchorage. This is an update of a Cochrane review first published in 2007. To assess the effects of surgical anchorage techniques compared to conventional anchorage in the prevention of unwanted tooth movement in patients undergoing orthodontic treatment by evaluating the mesiodistal movement of upper first molar teeth. A secondary objective was to compare the effects of one type of surgical anchorage with another. We searched the Cochrane Oral Health Group's Trials Register (to 28 October 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 9), MEDLINE via OVID (1946 to 28 October 2013) and EMBASE via OVID (1980 to 28 October 2013). We handsearched key international orthodontic and dental journals, and searched the trial database ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing and unpublished studies. Randomised controlled trials comparing surgical anchorage with conventional anchorage in orthodontic patients. Trials comparing two types of surgical anchorage were also included. At least two review authors independently and in duplicate extracted data and carried out risk of bias assessments. We contacted study authors to clarify aspects of study design and conduct, and to obtain unreported data. Fourteen new studies were added in this update resulting in a total of 15 studies reporting data from 561 randomised patients. The studies were conducted in Europe, India, China, South Korea and the USA. The age range of patients was commonly restricted to adolescents or young adults, however the participants of two studies were from a much wider age range (12 to 54 years). The distribution of males and females was similar in eight of the studies, with a predominance of female patients in seven studies.Eight studies were assessed to be at high overall risk of bias; six studies at unclear risk of bias; one study at low risk of bias.Ten studies with 407 randomised and 390 analysed patients compared surgical anchorage with conventional anchorage for the primary outcome of mesiodistal movement of upper first molars. We carried out a random-effects model meta-analysis for the seven studies that fully reported this outcome. There was strong evidence of an effect of surgical anchorage on this outcome. Compared with conventional anchorage, surgical anchorage was more effective in the reinforcement of anchorage by 1.68 mm (95% confidence interval (CI) -2.27 mm to -1.09 mm; seven studies, 308 participants analysed) with moderate quality of evidence (one study at high overall risk of bias, five studies at unclear risk of bias, one study at low risk of bias). This result should be interpreted with some caution, however, as there was a substantial degree of heterogeneity for this comparison. There was no evidence of a difference in overall duration of treatment between surgical and conventional anchorage (-0.15 years; 95% CI -0.37 years to 0.07 years; three studies, 111 analysed patients) with low quality of evidence (one study at high overall risk of bias and two studies at unclear risk of bias). Information on patient-reported outcomes such as pain and acceptability was limited and inconclusive.When direct comparisons were made between two types of surgical anchorage, there was a lack of evidence to suggest that any one technique was better than another.No included studies reported adverse effects. There is moderate quality evidence that reinforcement of anchorage is more effective with surgical anchorage than conventional anchorage, and that results from mini-screw implants are particularly promising. While surgical anchorage is not associated with the inherent risks and compliance issues related to extraoral headgear, none of the included studies reported on harms of surgical or conventional anchorage.

  1. Efficacy of Conventional Laser Irradiation Versus a New Method for Gingival Depigmentation (Sieve Method): A Clinical Trial.

    PubMed

    Houshmand, Behzad; Janbakhsh, Noushin; Khalilian, Fatemeh; Talebi Ardakani, Mohammad Reza

    2017-01-01

    Introduction: Diode laser irradiation has recently shown promising results for treatment of gingival pigmentation. This study sought to compare the efficacy of 2 diode laser irradiation protocols for treatment of gingival pigmentations, namely the conventional method and the sieve method. Methods: In this split-mouth clinical trial, 15 patients with gingival pigmentation were selected and their pigmentation intensity was determined using Dummett's oral pigmentation index (DOPI) in different dental regions. Diode laser (980 nm wavelength and 2 W power) was irradiated through a stipple pattern (sieve method) and conventionally in the other side of the mouth. Level of pain and satisfaction with the outcome (both patient and periodontist) were measured using a 0-10 visual analog scale (VAS) for both methods. Patients were followed up at 2 weeks, one month and 3 months. Pigmentation levels were compared using repeated measures of analysis of variance (ANOVA). The difference in level of pain and satisfaction between the 2 groups was analyzed by sample t test and general estimate equation model. Results: No significant differences were found regarding the reduction of pigmentation scores and pain and scores between the 2 groups. The difference in satisfaction with the results at the three time points was significant in both conventional and sieve methods in patients ( P = 0.001) and periodontists ( P = 0.015). Conclusion: Diode laser irradiation in both methods successfully eliminated gingival pigmentations. The sieve method was comparable to conventional technique, offering no additional advantage.

  2. The role of intraoperative MRI in resective epilepsy surgery for peri-eloquent cortex cortical dysplasias and heterotopias in pediatric patients.

    PubMed

    Sacino, Matthew F; Ho, Cheng-Ying; Murnick, Jonathan; Keating, Robert F; Gaillard, William D; Oluigbo, Chima O

    2016-03-01

    Previous studies have demonstrated that an important factor in seizure freedom following surgery for lesional epilepsy in the peri-eloquent cortex is completeness of resection. However, aggressive resection of epileptic tissue localized to this region must be balanced with the competing objective of retaining postoperative neurological functioning. The objective of this study was to investigate the role of intraoperative MRI (iMRI) as a complement to existing epilepsy protocol techniques and to compare rates of seizure freedom and neurological deficit in pediatric patients undergoing resection of perieloquent lesions. The authors retrospectively reviewed the medical records of pediatric patients who underwent resection of focal cortical dysplasia (FCD) or heterotopia localized to eloquent cortex regions at the Children's National Health System between March 2005 and August 2015. Patients were grouped into two categories depending on whether they underwent conventional resection (n = 18) or iMRI-assisted resection (n = 11). Patient records were reviewed for factors including demographics, length of hospitalization, postoperative seizure freedom, postoperative neurological deficit, and need for reoperation. Postsurgical seizure outcome was assessed at the last postoperative follow-up evaluation using the Engel Epilepsy Surgery Outcome Scale. At the time of the last postoperative follow-up examination, 9 (82%) of the 11 patients in the iMRI resection group were seizure free (Engel Class I), compared with 7 (39%) of the 18 patients in the control resection group (p = 0.05). Ten (91%) of the 11 patients in the iMRI cohort achieved gross-total resection (GTR), compared with 8 (44%) of 18 patients in the conventional resection cohort (p = 0.02). One patient in the iMRI-assisted resection group underwent successful reoperation at a later date for residual dysplasia, compared with 7 patients in the conventional resection cohort (with 2/7 achieving complete resection). Four (36%) of the patients in the iMRI cohort developed postoperative neurological deficits, compared with 15 patients (83%) in the conventional resection cohort (p = 0.02). These results suggest that in comparison with a conventional surgical protocol and technique for resection of epileptic lesions in peri-eloquent cortex, the incorporation of iMRI led to elevated rates of GTR and postoperative seizure freedom. Furthermore, this study suggests that iMRI-assisted surgeries are associated with a reduction in neurological deficits due to intraoperative damage of eloquent cortex.

  3. Dosimetric analysis of stereotactic body radiation therapy for pancreatic cancer using MR-guided Tri-60Co unit, MR-guided LINAC, and conventional LINAC-based plans.

    PubMed

    Ramey, Stephen James; Padgett, Kyle R; Lamichhane, Narottam; Neboori, Hanmath J; Kwon, Deukwoo; Mellon, Eric A; Brown, Karen; Duffy, Melissa; Victoria, James; Dogan, Nesrin; Portelance, Lorraine

    2018-03-01

    This study aims to perform a dosimetric comparison of 2 magnetic resonance (MR)-guided radiation therapy systems capable of performing online adaptive radiation therapy versus a conventional radiation therapy system for pancreas stereotactic body radiation therapy. Ten cases of patients with pancreatic adenocarcinoma previously treated in our institution were used for this analysis. MR-guided tri-cobalt 60 therapy (MR-cobalt) and MR-LINAC plans were generated and compared with conventional LINAC (volumetric modulated arc therapy) plans. The prescription dose was 40 Gy in 5 fractions covering 95% of the planning tumor volume for the 30 plans. The same organs at risk (OARs) dose constraints were used in all plans. Dose-volume-based indices were used to compare PTV coverage and OAR sparing. The conformity index of 40 Gy in 5 fractions covering 95% of the planning tumor volume demonstrated higher conformity in both LINAC-based plans compared with MR-cobalt plans. Although there was no difference in mean conformity index between LINAC and MR-LINAC plans (1.08 in both), there was a large difference between LINAC and MR-cobalt plans (1.08 vs 1.52). Overall, 79%, 72%, and 78% of critical structure dosimetric constraints were met with LINAC, MR-cobalt, and MR-LINAC plans, respectively. The MR-cobalt plans delivered more doses to all OARs compared with the LINAC plans. In contrast, the doses to the OARs of the MR-LINAC plans were similar to LINAC plans except in 2 cases: liver mean dose (MR-LINAC, 2 .8 Gy vs LINAC, 2.1 Gy) and volume of duodenum receiving at least 15 Gy (MR-LINAC, 13.2 mL vs LINAC, 15.4 mL). Both differences are likely not clinically significant. This study demonstrates that dosimetrically similar plans were achieved with conventional LINAC and MR-LINAC, whereas doses to OARs were statistically higher for MR-cobalt compared with conventional LINAC plans because of low-dose spillage. Given the improved tumor-tracking capabilities of MR-LINAC, further studies should evaluate potential benefits of adaptive radiation therapy-capable MR-guided LINAC treatment. Copyright © 2018. Published by Elsevier Inc.

  4. Comparison of Conventional and Microwave-assisted Synthesis of Benzimidazole Derivative from Citronellal in Kaffir lime oil (Citrus hystrix DC.)

    NASA Astrophysics Data System (ADS)

    Warsito, W.; Noorhamdani, A. S.; Suratmo; Dwi Sapri, R.; Alkaroma, D.; Azhar, A. Z.

    2018-04-01

    Simple method has been used for the synthesis of benzimidazole derivative from citronellal in kaffir lime oil under microwave irradiation. These compounds were synthesized also by conventional heating for comparison. In addtion, microwave-assited synthesis was also compared between using to dichloromethane and methanol solvents with variation of reaction time for 30 to 70 minutes and 4 to 12 h for conventional heating. The 2-citronellyl benzimidazole compound synthesized were characterised by FT-IR, GC-MS, 1H and 13C NMR spectroscopy. Comparison between conventional and microwave-assisted synthesis was done by comparing between correlation of reaction time and percentage yield. The time optimum of microwave-assisted and conventional synthesis using dichloromethane solvent respectively at 60 minutes (yield 19.23%) and 8 hours (yield 11.54%). In addition, microwave-assited synthesis increasing 157.81 times compared by conventional heating. While using methanol solvent tends to increase linearly however the percentage of yield only 0.77 times of synthesis using dichloromethane solvent.

  5. Parasites and parasite management practices of organic and conventional dairy herds in Minnesota.

    PubMed

    Sorge, U S; Moon, R D; Stromberg, B E; Schroth, S L; Michels, L; Wolff, L J; Kelton, D F; Heins, B J

    2015-05-01

    The objective of this study was to describe the prevalence and practices used to manage internal helminth parasites and external arthropod parasites on organic and conventional dairy herds in Minnesota. All organic (ORG) dairy herds in Minnesota (n=114) and a convenience sample of conventional herds were invited to participate in the study. Thirty-five ORG herds and 28 conventional herds were visited once in summer and fall of 2012. Conventional dairy herds were split into small conventional (SC,<200 cows) and medium-sized conventional herds (MC, ≥200 cows) so that SC herds were comparable in size to the ORG herds. Dairy managers were surveyed to assess their farm management practices and perceptions about parasites, hygiene scores were recorded for adult stock, and fecal samples were collected from a nominal 20 breeding-age heifers to characterize abundance of internal parasites. Nonparametric tests were used to compare fecal egg counts per gram (FEC) among farms grouped by management systems and practices. Organic farms had more designated pasture and were more likely to use rotational grazing compared with conventional farms, but the stocking densities of animals on pasture were similar among farm types. The overall FEC were very low, and only a few individual ORG heifers had FEC >500 eggs/gram. Samples from heifers on ORG farms had significantly more strongyle-type eggs than those on SC and MC farms (ORG: 6.6±2.1; SC: 0.5±0.3; MC: 0.8±0.7), but egg counts of other types of gastrointestinal parasites did not differ significantly among the 3 herd groups. Fly control measures were applied mainly to milking cows and preweaned calves and were used on 88.6% of ORG herds, 60.0% of SC herds, and 91.7% of MC herds. Approximately half of the producers reported having seen skin conditions suggestive of lice or tail mange in their cattle during the previous winter (ORG: 48.6%, SC: 57.1%, MC: 53.9%). Although most conventional producers reported treating these skin conditions, most organic producers stated they had not treated them. In conclusion, gastrointestinal parasite egg counts were low overall at the time of the survey, and most surveyed producers did not perceive gastrointestinal parasites to be a problem for their animals' health. Independent of the herd type, fly control was mostly targeted at the lactating herd and preweaned calves. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Conventional vs. reduced field of view diffusion weighted imaging of the prostate: Comparison of image quality, correlation with histology, and inter-reader agreement.

    PubMed

    Warndahl, Brent A; Borisch, Eric A; Kawashima, Akira; Riederer, Stephen J; Froemming, Adam T

    2018-04-01

    To evaluate if Field of view Optimized and Constrained Undistorted Single shot (FOCUS) (GE Healthcare, Waukesha, WI) diffusion weighted images (DWI) provide more reliable imaging than conventional DWI, with non-inferior quantitative apparent diffusion coefficient (ADC) results. IRB approval was obtained for this study of 43 patients (44 exams, one patient with two visits) that underwent multiparametric prostate MRI with two DWI sequences and subsequent radical prostatectomy with histology as the gold standard. Randomized DWI sequence images were graded independently by two blinded experienced prostate MRI radiologists with a period of memory extinction between the two separate reading sessions. Blinded images were also reviewed head to head in a later session for direct comparison. Multiple parameters were measured from a region of interest in a dominant lesion as well as two control areas. Patient characteristics were collected by chart review. There was good correlation between the mean ADC value for lesions obtained by conventional and FOCUS DWI (ρ=0.85), with no trend toward any systematic difference, and equivalent correlation between ADC measurements and Gleason score. Agreement between the two readers was significantly higher for lesion ROI analysis with the FOCUS DWI derived ADC values (CCC 0.839) compared with the conventional ADC values (CCC 0.618; difference 0.221, 95% CI 0.01-0.46). FOCUS showed significantly better image quality scores (separate review: mean 2.17±0.6, p<0.001) compared to the conventional sequence (mean 2.65±0.6, p<0.001). In 13 cases the image quality was improved from grade of 3+ with conventional DWI to <3 with FOCUS DWI, a clinically meaningful improvement. Head-to-head blinded review found 61 ratings showed strong to slight preference for FOCUS, 13 no preference, and 14 slight preference for the conventional sequence. There was also a strong and equivalent correlation between both sequences and PIRADS version 2 grading (ρ=-0.56 and -0.58 for FOCUS and conventional, respectively, p<0.001 for both). FOCUS DWI of the prostate shows significant improvement in inter-reader agreement and image quality. As opposed to previous conflicting smaller studies, we found equivalent ADC metrics compared with the conventional DWI sequence, and preserved correlation with Gleason score. In 52% of patients the improved image quality with FOCUS had the potential to salvage exams with otherwise limited to non-diagnostic DWI. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Cost-effectiveness of modern radiotherapy techniques in locally advanced pancreatic cancer.

    PubMed

    Murphy, James D; Chang, Daniel T; Abelson, Jon; Daly, Megan E; Yeung, Heidi N; Nelson, Lorene M; Koong, Albert C

    2012-02-15

    Radiotherapy may improve the outcome of patients with pancreatic cancer but at an increased cost. In this study, the authors evaluated the cost-effectiveness of modern radiotherapy techniques in the treatment of locally advanced pancreatic cancer. A Markov decision-analytic model was constructed to compare the cost-effectiveness of 4 treatment regimens: gemcitabine alone, gemcitabine plus conventional radiotherapy, gemcitabine plus intensity-modulated radiotherapy (IMRT); and gemcitabine with stereotactic body radiotherapy (SBRT). Patients transitioned between the following 5 health states: stable disease, local progression, distant failure, local and distant failure, and death. Health utility tolls were assessed for radiotherapy and chemotherapy treatments and for radiation toxicity. SBRT increased life expectancy by 0.20 quality-adjusted life years (QALY) at an increased cost of $13,700 compared with gemcitabine alone (incremental cost-effectiveness ratio [ICER] = $69,500 per QALY). SBRT was more effective and less costly than conventional radiotherapy and IMRT. An analysis that excluded SBRT demonstrated that conventional radiotherapy had an ICER of $126,800 per QALY compared with gemcitabine alone, and IMRT had an ICER of $1,584,100 per QALY compared with conventional radiotherapy. A probabilistic sensitivity analysis demonstrated that the probability of cost-effectiveness at a willingness to pay of $50,000 per QALY was 78% for gemcitabine alone, 21% for SBRT, 1.4% for conventional radiotherapy, and 0.01% for IMRT. At a willingness to pay of $200,000 per QALY, the probability of cost-effectiveness was 73% for SBRT, 20% for conventional radiotherapy, 7% for gemcitabine alone, and 0.7% for IMRT. The current results indicated that IMRT in locally advanced pancreatic cancer exceeds what society considers cost-effective. In contrast, combining gemcitabine with SBRT increased clinical effectiveness beyond that of gemcitabine alone at a cost potentially acceptable by today's standards. Copyright © 2011 American Cancer Society.

  8. Physical activity when riding an electric assisted bicycle.

    PubMed

    Berntsen, Sveinung; Malnes, Lena; Langåker, Aleksander; Bere, Elling

    2017-04-26

    The objectives of the present study were to compare time spent cycling, exercise intensity, and time spent in moderate- (MPA) and vigorous intensity physical activity (VPA) when cycling on an E-bike and a conventional bicycle on two "cycling-to-work" routes with differences in topography, defined as a hilly and a flat route. Eight adults (23-54 years, two women) cycled outdoors on a conventional bicycle and an E-bike, on a flat (8.2 km) and a hilly (7.1 km) route, resulting in 32 journeys. Duration, elevation, and oxygen consumption were recorded using a portable oxygen analyser with GPS. A maximal cardiorespiratory fitness test was performed on a cycle ergometer. Resting metabolic rate was obtained by indirect calorimetry with a canopy hood. The participants spent less time (median (IQR)) cycling on the E-bike compared with the conventional bicycle, on both the hilly (18.8 (4.9) vs. 26.3 (6.4) minutes) and the flat (20.0 (2.9) vs. 23.8 (1.8) minutes) routes. Lower exercise intensity was observed with the E-bike compared with the conventional bicycle, both on the hilly (50 (18) vs. 60 (22) % of maximal oxygen uptake) and the flat (52 (19) vs. 55 (12) % of maximal oxygen uptake) routes. In both cycling modes, most time was spent in MVPA (92-99%). However, fewer minutes were spent in MVPA with the E-bike than the conventional bicycle, for both the hilly (26% lower) and the flat (17% lower) routes. Cycling on the E-bike also resulted in 35 and 15% fewer minutes in vigorous intensity, respectively on the hilly and flat routes. Cycling on the E-bike resulted in lower trip duration and exercise intensity, compared with the conventional bicycle. However, most of the time was spent in MVPA. This suggests that changing the commuting mode from car to E-bike will significantly increase levels of physical activity while commuting.

  9. Comparison of the immunogenicity and safety of the conventional subunit, MF59-adjuvanted, and intradermal influenza vaccines in the elderly.

    PubMed

    Seo, Yu Bin; Choi, Won Suk; Lee, Jacob; Song, Joon Young; Cheong, Hee Jin; Kim, Woo Joo

    2014-07-01

    The influenza vaccination is known as the most effective method for preventing influenza infection and its complications in the elderly. Conventional subunit (Agrippal S1; Novartis), MF59-adjuvanted (Fluad; Novartis), and intradermal (IDflu15; Sanofi Pasteur) influenza vaccines are widely used throughout South Korea. However, few comparative studies evaluating the safety and immunogenicity of these vaccines are available. Prior to the beginning of the 2011-2012 influenza season, 335 healthy elderly volunteers randomly received one of three seasonal trivalent influenza vaccines, the conventional subunit, MF59-adjuvanted, or intradermal influenza vaccine. Serum hemagglutination-inhibiting antibody levels were measured at the time of vaccination and at 1 and 6 months after vaccination. Adverse events were recorded prospectively. A total of 113 conventional subunit, 111 MF59-adjuvanted, and 111 intradermal influenza vaccine volunteers were followed up during a 6-month postvaccination period. One month after vaccination, all three vaccines satisfied Committee for Medical Products for Human Use (CHMP) immunogenicity criteria for the A/H1N1 and A/H3N2 strains but not for the B strain. Compared with the subunit vaccine, the intradermal vaccine exhibited noninferiority, while the MF59-adjuvanted vaccine exhibited superiority. Furthermore, the MF59-adjuvanted vaccine was more immunogenic against the A/H3N2 strain than was the subunit vaccine up to 6 months postvaccination. The most common local and systemic reactions to the conventional subunit, MF59-adjuvanted, and intradermal influenza vaccines were pain at the injection site (7.1%, 10.8%, and 6.3%, respectively) and generalized myalgia (0.9%, 8.1%, and 5.4%, respectively). Local and systemic reactions were similar among the three vaccine groups. MF59-adjuvanted vaccine exhibited superior immunogenicity compared with a conventional subunit vaccine and had a comparable safety profile. For older adults, the MF59-adjuvanted vaccine is preferable for providing superior immunogenicity. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  10. Characterization and stability studies of a novel liposomal cyclosporin A prepared using the supercritical fluid method: comparison with the modified conventional Bangham method

    PubMed Central

    Karn, Pankaj Ranjan; Cho, Wonkyung; Park, Hee-Jun; Park, Jeong-Sook; Hwang, Sung-Joo

    2013-01-01

    A novel method to prepare cyclosporin A encapsulated liposomes was introduced using supercritical fluid of carbon dioxide (SCF-CO2) as an antisolvent. To investigate the strength of the newly developed SCF-CO2 method compared with the modified conventional Bangham method, particle size, zeta potential, and polydispersity index (PDI) of both liposomal formulations were characterized and compared. In addition, entrapment efficiency (EE) and drug loading (DL) characteristics were analyzed by reversed-phase high-performance liquid chromatography. Significantly larger particle size and PDI were revealed from the conventional method, while EE (%) and DL (%) did not exhibit any significant differences. The SCF-CO2 liposomes were found to be relatively smaller, multilamellar, and spherical with a smoother surface as determined by transmission electron microscopy. SCF-CO2 liposomes showed no significant differences in their particle size and PDI after more than 3 months, whereas conventional liposomes exhibited significant changes in their particle size. The initial yield (%), EE (%), and DL (%) of SCF-CO2 liposomes and conventional liposomes were 90.98 ± 2.94, 92.20 ± 1.36, 20.99 ± 0.84 and 90.72 ± 2.83, 90.24 ± 1.37, 20.47 ± 0.94, respectively, which changed after 14 weeks to 86.65 ± 0.30, 87.63 ± 0.72, 18.98 ± 0.22 and 75.04 ± 8.80, 84.59 ± 5.13, 15.94 ± 2.80, respectively. Therefore, the newly developed SCF-CO2 method could be a better alternative compared with the conventional method and may provide a promising approach for large-scale production of liposomes. PMID:23378759

  11. Image quality assessment of silent T2 PROPELLER sequence for brain imaging in infants.

    PubMed

    Kim, Hyun Gi; Choi, Jin Wook; Yoon, Soo Han; Lee, Sieun

    2018-02-01

    Infants are vulnerable to high acoustic noise. Acoustic noise generated by MR scanning can be reduced by a silent sequence. The purpose of this study is to compare the image quality of the conventional and silent T2 PROPELLER sequences for brain imaging in infants. A total of 36 scans were acquired from 24 infants using a 3 T MR scanner. Each patient underwent both conventional and silent T2 PROPELLER sequences. Acoustic noise level was measured. Quantitative and qualitative assessments were performed with the images taken with each sequence. The sound pressure level of the conventional T2 PROPELLER imaging sequence was 92.1 dB and that of the silent T2 PROPELLER imaging sequence was 73.3 dB (reduction of 20%). On quantitative assessment, the two sequences (conventional vs silent T2 PROPELLER) did not show significant difference in relative contrast (0.069 vs 0.068, p value = 0.536) and signal-to-noise ratio (75.4 vs 114.8, p value = 0.098). Qualitative assessment of overall image quality (p value = 0.572), grey-white differentiation (p value = 0.986), shunt-related artefact (p value > 0.999), motion artefact (p value = 0.801) and myelination degree in different brain regions (p values ≥ 0.092) did not show significant difference between the two sequences. The silent T2 PROPELLER sequence reduces acoustic noise and generated comparable image quality to that of the conventional sequence. Advances in knowledge: This is the first report to compare silent T2 PROPELLER images with that of conventional T2 PROPELLER images in children.

  12. When is rotational angiography superior to conventional single-plane angiography for planning coronary angioplasty?

    PubMed

    Morris, Paul D; Taylor, Jane; Boutong, Sara; Brett, Sarah; Louis, Amal; Heppenstall, James; Morton, Allison C; Gunn, Julian P

    2016-03-01

    To investigate the value of rotational coronary angiography (RoCA) in the context of percutaneous coronary intervention (PCI) planning. As a diagnostic tool, RoCA is associated with decreased patient irradiation and contrast use compared with conventional coronary angiography (CA) and provides superior appreciation of three-dimensional anatomy. However, its value in PCI remains unknown. We studied stable coronary artery disease assessment and PCI planning by interventional cardiologists. Patients underwent either RoCA or conventional CA pre-PCI for planning. These were compared with the referral CA (all conventional) in terms of quantitative lesion assessment and operator confidence. An independent panel reanalyzed all parameters. Six operators performed 127 procedures (60 RoCA, 60 conventional CA, and 7 crossed-over) and assessed 212 lesions. RoCA was associated with a reduction in the number of lesions judged to involve a bifurcation (23 vs. 30 lesions, P < 0.05) and a reduction in the assessment of vessel caliber (2.8 vs. 3.0 mm, P < 0.05). RoCA improved confidence assessing lesion length (P = 0.01), percentage stenosis (P = 0.02), tortuosity (P < 0.04), and proximity to a bifurcation (P = 0.03), particularly in left coronary artery cases. X-ray dose, contrast agent volume, and procedure duration were not significantly different. Compared with conventional CA, RoCA augments quantitative lesion assessment, enhances confidence in the assessment of coronary artery disease and the precise details of the proposed procedure, but does not affect X-ray dose, contrast agent volume, or procedure duration. © 2015 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  13. Design, simulation and comparative analysis of CNT based cascode operational transconductance amplifiers

    NASA Astrophysics Data System (ADS)

    Nizamuddin, M.; Loan, Sajad A.; Alamoud, Abdul R.; Abbassi, Shuja A.

    2015-10-01

    In this work, design and calibrated simulation of carbon nanotube field effect transistor (CNTFET)-based cascode operational transconductance amplifiers (COTA) have been performed. Three structures of CNTFET-based COTAs have been designed using HSPICE and have been compared with the conventional CMOS-based COTAs. The proposed COTAs include one using pure CNTFETs and two others that employ CNTFETs, as well as the conventional MOSFETs. The simulation study has revealed that the CNTFET-based COTAs have significantly outperformed the conventional MOSFET-based COTAs. A significant increase in dc gain, output resistance and slew rate of 81.4%, 25% and 13.2%, respectively, have been achieved in the proposed pure CNT-based COTA in comparison to the conventional CMOS-based COTA. The power consumption in the pure CNT-COTA is 324 times less in comparison to the conventional CMOS-COTA. Further, the phase margin (PM), gain margin (GM), common mode and power supply rejection ratios have been significantly increased in the proposed CNT-based COTAs in comparison to the conventional CMOS-based COTAs. Furthermore, to see the advantage of cascoding, the proposed CNT-based cascode OTAs have been compared with the CNT-based OTAs. It has been observed that by incorporating the concept of cascode in the CNTFET-based OTAs, significant increases in gain (12.5%) and output resistance (13.07%) have been achieved. The performance of the proposed COTAs has been further observed by changing the number of CNTs (N), CNT pitch (S) and CNT diameter (DCNT) in the CNTFETs used. It has been observed that the performance of the proposed COTAs can be significantly improved by using optimum values of N, S and DCNT.

  14. Comparison of conventional versus Hybrid knife peroral endoscopic myotomy methods for esophageal achalasia: a case-control study.

    PubMed

    Tang, Xiaowei; Gong, Wei; Deng, Zhiliang; Zhou, Jieqiong; Ren, Yutang; Zhang, Qiang; Chen, Zhenyu; Jiang, Bo

    2016-01-01

    Peroral endoscopic myotomy (POEM) has been developed to treat achalasia as a novel less invasive modality. We aimed to compare the efficacy and safety of conventional knife versus Hybrid knife (HK) during POEM procedure. Between June 2012 and July 2014, 31 patients underwent POEM using HK in our department (HK group), and 36 patients underwent POEM using conventional method (injection needle and triangular tip [TT] knife, TT group). Procedure-related parameters, symptom relief, adverse events were compared between two groups. There were no significant differences in the age, sex and other baseline characteristics between the two groups. The mean procedural time was significantly shorter in HK group than TT group (53.0 ± 17.2 vs. 67.6 ± 28.4 min, p = 0.015). The mean frequency of devices exchange was 4.7 ± 1.7 in HK group and 10.9 ± 1.8 in TT group (p = 0.000). No serious adverse events occurred postoperatively in both groups. At one-year follow-up, a total of 94% treatment success was achieved in all patients (93.5% in HK group and 94.4% in TT group, p = 0.877). HK in POEM can shorten the procedural time, and achieve similar treatment success compared to conventional TT knife.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Yasin; Khare, Vaibhav Rai; Mathur, Jyotirmay

    The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building usingmore » a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.« less

  16. Accuracy assessment methods of tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: comparison of measurements using direct and conventional methods.

    PubMed

    Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo

    2017-07-01

    The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.

  17. Transcriptome Sequencing Reveals Large-Scale Changes in Axenic Aedes aegypti Larvae

    PubMed Central

    Vogel, Kevin J.; Valzania, Luca; Coon, Kerri L.; Brown, Mark R.; Strand, Michael R.

    2017-01-01

    Mosquitoes host communities of microbes in their digestive tract that consist primarily of bacteria. We previously reported that Aedes aegypti larvae colonized by a native community of bacteria and gnotobiotic larvae colonized by only Escherichia coli develop very similarly into adults, whereas axenic larvae never molt and die as first instars. In this study, we extended these findings by first comparing the growth and abundance of bacteria in conventional, gnotobiotic, and axenic larvae during the first instar. Results showed that conventional and gnotobiotic larvae exhibited no differences in growth, timing of molting, or number of bacteria in their digestive tract. Axenic larvae in contrast grew minimally and never achieved the critical size associated with molting by conventional and gnotobiotic larvae. In the second part of the study we compared patterns of gene expression in conventional, gnotobiotic and axenic larvae by conducting an RNAseq analysis of gut and nongut tissues (carcass) at 22 h post-hatching. Approximately 12% of Ae. aegypti transcripts were differentially expressed in axenic versus conventional or gnotobiotic larvae. However, this profile consisted primarily of transcripts in seven categories that included the down-regulation of select peptidases in the gut and up-regulation of several genes in the gut and carcass with roles in amino acid transport, hormonal signaling, and metabolism. Overall, our results indicate that axenic larvae exhibit alterations in gene expression consistent with defects in acquisition and assimilation of nutrients required for growth. PMID:28060822

  18. Effects of butter from mountain-pasture grazing cows on risk markers of the metabolic syndrome compared with conventional Danish butter: a randomized controlled study.

    PubMed

    Werner, Louise B; Hellgren, Lars I; Raff, Marianne; Jensen, Søren K; Petersen, Rikke A; Drachmann, Tue; Tholstrup, Tine

    2013-07-10

    There is considerable interest in dairy products from low-input systems, such as mountain-pasture grazing cows, because these products are believed to be healthier than products from high-input conventional systems. This may be due to a higher content of bioactive components, such as phytanic acid, a PPAR-agonist derived from chlorophyll. However, the effects of such products on human health have been poorly investigated. To compare the effect of milk-fat from mountain-pasture grazing cows (G) and conventionally fed cows (C) on risk markers of the metabolic syndrome. In a double-blind, randomized, 12-week, parallel intervention study, 38 healthy subjects replaced part of their habitual dietary fat intake with 39 g fat from test butter made from milk from mountain-pasture grazing cows or from cows fed conventional winter fodder. Glucose-tolerance and circulating risk markers were analysed before and after the intervention. No differences in blood lipids, lipoproteins, hsCRP, insulin, glucose or glucose-tolerance were observed. Interestingly, strong correlations between phytanic acid at baseline and total (P<0.0001) and LDL cholesterol (P=0.0001) were observed. Lack of effects on blood lipids and inflammation indicates that dairy products from mountain-pasture grazing cows are not healthier than products from high-input conventional systems. Considering the strong correlation between LDL cholesterol and phytanic acid at baseline, it may be suggested that phytanic acid increases total and LDL cholesterol. ClinicalTrials.gov, NCT01343589.

  19. Comparison of conventional therapies for dentin hypersensitivity versus medical hypnosis.

    PubMed

    Eitner, Stephan; Bittner, Christian; Wichmann, Manfred; Nickenig, Hans-Joachim; Sokol, Biljana

    2010-10-01

    This study compared the efficacy of conventional treatments for dentin hypersensitivity (DHS) and hypnotherapy. During a 1-month period at an urban practice in a service area of approximately 22,000 inhabitants, all patients were examined. A total of 102 individuals were included in the evaluation. Values of 186 teeth were analyzed. The comparison of the different treatment methods (desensitizer, fluoridation, and hypnotherapy) did not show significant differences in success rates. However, a noticeable difference was observed in terms of onset and duration of effect. For both desensitizer and hypnotherapy treatments, onset of effect was very rapid. Compared to the other methods studied, hypnotherapy effects had the longest duration. In conclusion, hypnotherapy was as effective as other methods in the treatment of DHS.

  20. Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis compared with conventional staplers: A real-world analysis in Chinese colorectal cancer patients.

    PubMed

    Lu, Zhenhai; Peng, Jianhong; Li, Cong; Wang, Fulong; Jiang, Wu; Fan, Wenhua; Lin, Junzhong; Wu, Xiaojun; Wan, Desen; Pan, Zhizhong

    2016-05-01

    This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples. In total, 234 consecutive patients diagnosed with colorectal cancer receiving sigmoidectomy and anterior resection for end-to-end anastomosis from May 2010 to June 2012 were retrospectively analyzed. The postoperative clinical parameters, postoperative complications and 3-year overall survival in 77 patients using a NiTi CAR 27 compression ring (CAR group) and 157 patients with conventional circular staplers (STA group) were compared. There were no statistically significant differences between the patients in the two groups in terms of general demographics and tumor features. A clinically apparent anastomotic leak occurred in 2 patients (2.6%) in the CAR group and in 5 patients (3.2%) in the STA group (p=0.804). These eight patients received a temporary diverting ileostomy. One patient (1.3%) in the CAR group was diagnosed with anastomotic stricture through an electronic colonoscopy after 3 months postoperatively. The incidence of postoperative intestinal obstruction was comparable between the two groups (p=0.192). With a median follow-up duration of 39.6 months, the 3-year overall survival rate was 83.1% in the CAR group and 89.0% in the STA group (p=0.152). NiTi CAR 27 is safe and effective for colorectal end-to-end anastomosis. Its use is equivalent to that of the conventional circular staplers. This study suggests that NiTi CAR 27 may be a beneficial alternative in colorectal anastomosis in Chinese colorectal cancer patients.

  1. Comparative study of conventional US, contrast enhanced US and enhanced MR for the follow-up of prostatic radiofrequency ablation.

    PubMed

    Feng, Chao; Hu, Bin; Hu, Bing; Chen, Lei; Li, Jia; Huang, Jin

    2017-06-01

    The aim of the present study was to evaluate and compare the effectiveness of different imaging methods during follow-up of prostatic radiofrequency ablation. Prostatic radiofrequency ablation (RFA) was performed in 20 healthy beagle dogs. Various imaging examinations were used to monitor the results of RFA, including conventional ultrasound (US), contrast enhanced ultrasound (CEUS) and enhanced magnetic resonance (MR). Imaging exams were performed at five phases: Immediately following RFA, one week later, one month later, three months later and six months later. The morphology for each imaging test and histological results were recorded and compared in each phase. Based on the actual results from autopsy, the accuracy of those imaging exams was evaluated. The canine prostate gland demonstrated typical coagulative necrosis immediately following RFA. The lesion would develop into stable cyst if no other complications occurred within the six-month follow-up. Regarding the RFA lesion volume measurement and the reflection of pathological changes, conventional US was not able to accurately measure the volume of RFA lesion and missed many more details concerning the RFA-treated area than CEUS and MR during the three months. The results from CEUS exhibited comparable accuracy to those from enhanced MR at each phase. However, there were no significant differences in the results from US, CEUS and MR at six months, which may contribute to the complete formation of lesion cyst. In the early phase, conventional US was not sufficient for evaluating the efficacy of RFA. Enhanced US and MR provided clear images and accurate information. However, CEUS has the advantage of being more economical, using more convenient equipment and faster scanning, thus identifying it as the more feasible choice. Furthermore, no notable advantages were observed among any image examinations in the long-term follow-up.

  2. Colour stainability of indirect CAD-CAM processed composites vs. conventionally laboratory processed composites after immersion in staining solutions.

    PubMed

    Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R

    2014-07-01

    The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (p<0.01) when compared to control group. The highest ΔE00 observed was with red wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Comparing the impact of homogenization and heat processing on the properties and in vitro digestion of milk from organic and conventional dairy herds

    USDA-ARS?s Scientific Manuscript database

    The effects of homogenization and heat processing on the chemical and in vitro digestion traits of milk from organic and conventional herds were compared. Raw milk from organic (>50% of dry matter intake from pasture) and conventional (no access to pasture) farms were adjusted to commercial whole a...

  4. Comparison of organochlorine pesticides and polychlorinated biphenyls residues in vegetables, grain and soil from organic and conventional farming in Poland.

    PubMed

    Witczak, Agata; Abdel-Gawad, Hassan

    2012-01-01

    Organic and conventional crops were studied by identifying the relationship between persistent organic pollutants in cereals, vegetables and soil. The residues of organochlorine pesticides and polychlorinated biphenyls (PCBs) were determined in grains (rye and wheat), vegetables (carrots and beets) and soil collected from the fields. PCB residues recorded in the beets from organic farming were as high as 3.71 ppb dry weight (dry wt.), while in the soil from conventional farming of beets 0.53 ppb dry wt. Among vegetables, higher concentrations of pesticides were detected in organically grown beets (190.63 ppb dry wt.). Soil samples from the organic farming contained lower levels of organochlorine pesticide residues compared to the conventional farming. Taking into account toxicity equivalent (TEQ), the conventionally grown carrots accumulated the most toxic PCBs. Non-ortho and mono-ortho PCBs were also noted in the grain of conventionally grown rye and amounted to 3.05 pg-TEQ/g wet wt.

  5. Moisture distribution during conventional or electrical resistance oven baking of bread dough and subsequent storage.

    PubMed

    Derde, Liesbeth J; Gomand, Sara V; Courtin, Christophe M; Delcour, Jan A

    2014-07-09

    Electrical resistance oven (ERO) baking processes bread dough with little temperature gradient in the baking dough. Heating of the dough by means of an ERO is based on the principles of Joule's first law and Ohm's law. This study compared the changes in moisture distribution and physical changes in starch of breads conventionally baked or using an ERO. The moisture contents in fresh ERO breads are generally lower than those in conventional breads. During storage of conventionally baked breads, water migrates from the crumb to the crust and moisture contents decrease throughout the bread crumb. Evidently, less moisture redistribution occurs in ERO breads. Also, the protons of ERO bread constituents were less mobile than their counterparts in conventional bread. Starch retrogradation occurs to similar extents in conventional and ERO bread. As a result, the changes in proton mobility cannot be attributed to differences in levels of retrograded starch and seem to be primarily determined by the overall lower moisture content.

  6. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  7. Psoralen-ultraviolet A treatment with Psoralen-ultraviolet B therapy in the treatment of psoriasis.

    PubMed

    Ahmed Asim, Sadaf; Ahmed, Sitwat; Us-Sehar, Najam

    2013-05-01

    To compare the conventional psoralen-ultraviolet A treatment with psoralen-ultraviolet B therapy in the treatment of psoriasis. We studied 50 patients of plaque type psoriasis who were selected to receive either conventional psoralen-ultraviolet A or psoralen-ultraviolet B treatment. There was no significant difference between the two treatment groups in the number of patients whose skin cleared of psoriasis or the number of exposures required for clearance. Profile of side effects and disease status was also similar after three months of follow up. Psoralen-ultraviolet B treatment is as effective as conventional psoralen-ultraviolet A in the treatment of psoriasis. Further long term studies are needed to assess the safety of psoralen-ultraviolet B.

  8. Comparison of the iAssist Handheld Guidance System to Conventional Instruments for Mechanical Axis Restoration in Total Knee Arthroplasty.

    PubMed

    Kinney, Matthew C; Cidambi, Krishna R; Severns, Dustyn L; Gonzales, Francis B

    2018-01-01

    Recent advances in total knee arthroplasty (TKA) include an intelligent instrument system designed to provide intraoperative guidance to reduce mechanical alignment errors. Internal position-sensing technology is integrated into microelectronic pods that attach to cutting blocks. The purpose of this prospective, randomized study was to determine whether this iAssist system enables the surgeon to make more accurate bone resections and better restore the mechanical axis compared to conventional instruments in TKA. We randomized patients undergoing TKA into 2 groups. Group I (n = 25) underwent TKA assisted by the iAssist guidance system, group II (n = 25) underwent TKA using conventional instruments. Preoperative and postoperative mechanical axes were measured from full-length lower extremity radiographs to evaluate alignment. Additional surgical parameters were also assessed, including tourniquet time and blood loss. Patient demographics and preoperative mechanical axis alignments were similar between the groups. Postoperatively, 4.0% of patients had greater than 3° of tibial or femoral component mal-alignment in the guidance-assisted cohort, compared with 36.0% in the conventional group (P < .05). Additionally, group I showed significant improvement in variance seen in both the femoral mechanical axis (1.65° ± 0.17° vs 2.23° ± 0.33°, P < .005) and tibial mechanical axis (1.28° ± 0.13° vs 1.71° ± 0.24°, P < .005) compared to group II. There were no significant differences in tourniquet time (P = .86) or blood loss (P = .39) between groups. Use of the iAssist system in TKA results in an improved postoperative mechanical axis and decreased alignment variability compared to conventional instruments, without significantly increasing operative time. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Job requirements compared to medical school education: differences between graduates from problem-based learning and conventional curricula

    PubMed Central

    2010-01-01

    Background Problem-based Learning (PBL) has been suggested as a key educational method of knowledge acquisition to improve medical education. We sought to evaluate the differences in medical school education between graduates from PBL-based and conventional curricula and to what extent these curricula fit job requirements. Methods Graduates from all German medical schools who graduated between 1996 and 2002 were eligible for this study. Graduates self-assessed nine competencies as required at their day-to-day work and as taught in medical school on a 6-point Likert scale. Results were compared between graduates from a PBL-based curriculum (University Witten/Herdecke) and conventional curricula. Results Three schools were excluded because of low response rates. Baseline demographics between graduates of the PBL-based curriculum (n = 101, 49% female) and the conventional curricula (n = 4720, 49% female) were similar. No major differences were observed regarding job requirements with priorities for "Independent learning/working" and "Practical medical skills". All competencies were rated to be better taught in PBL-based curriculum compared to the conventional curricula (all p < 0.001), except for "Medical knowledge" and "Research competence". Comparing competencies required at work and taught in medical school, PBL was associated with benefits in "Interdisciplinary thinking" (Δ + 0.88), "Independent learning/working" (Δ + 0.57), "Psycho-social competence" (Δ + 0.56), "Teamwork" (Δ + 0.39) and "Problem-solving skills" (Δ + 0.36), whereas "Research competence" (Δ - 1.23) and "Business competence" (Δ - 1.44) in the PBL-based curriculum needed improvement. Conclusion Among medical graduates in Germany, PBL demonstrated benefits with regard to competencies which were highly required in the job of physicians. Research and business competence deserve closer attention in future curricular development. PMID:20074350

  10. Job requirements compared to medical school education: differences between graduates from problem-based learning and conventional curricula.

    PubMed

    Schlett, Christopher L; Doll, Hinnerk; Dahmen, Janosch; Polacsek, Ole; Federkeil, Gero; Fischer, Martin R; Bamberg, Fabian; Butzlaff, Martin

    2010-01-14

    Problem-based Learning (PBL) has been suggested as a key educational method of knowledge acquisition to improve medical education. We sought to evaluate the differences in medical school education between graduates from PBL-based and conventional curricula and to what extent these curricula fit job requirements. Graduates from all German medical schools who graduated between 1996 and 2002 were eligible for this study. Graduates self-assessed nine competencies as required at their day-to-day work and as taught in medical school on a 6-point Likert scale. Results were compared between graduates from a PBL-based curriculum (University Witten/Herdecke) and conventional curricula. Three schools were excluded because of low response rates. Baseline demographics between graduates of the PBL-based curriculum (n = 101, 49% female) and the conventional curricula (n = 4720, 49% female) were similar. No major differences were observed regarding job requirements with priorities for "Independent learning/working" and "Practical medical skills". All competencies were rated to be better taught in PBL-based curriculum compared to the conventional curricula (all p < 0.001), except for "Medical knowledge" and "Research competence". Comparing competencies required at work and taught in medical school, PBL was associated with benefits in "Interdisciplinary thinking" (Delta + 0.88), "Independent learning/working" (Delta + 0.57), "Psycho-social competence" (Delta + 0.56), "Teamwork" (Delta + 0.39) and "Problem-solving skills" (Delta + 0.36), whereas "Research competence" (Delta--1.23) and "Business competence" (Delta--1.44) in the PBL-based curriculum needed improvement. Among medical graduates in Germany, PBL demonstrated benefits with regard to competencies which were highly required in the job of physicians. Research and business competence deserve closer attention in future curricular development.

  11. Methods for Equating Mental Tests.

    DTIC Science & Technology

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  12. Perceived Risks and Normative Beliefs as Explanatory Models for College Student Alcohol Involvement: An Assessment of a Campus with Conventional Alcohol Control Policies and Enforcement Practices

    ERIC Educational Resources Information Center

    Lewis, Todd F.; Thombs, Dennis L.

    2005-01-01

    The aim of this study was to conduct a multivariate assessment of college student drinking motivations at a campus with conventional alcohol control policies and enforcement practices, including the establishment and dissemination of alcohol policies and the use of warnings to arouse fear of sanctions. Two explanatory models were compared:…

  13. A novel bile salts-lipase polymeric film-infused minitablet system for enhanced oral delivery of cholecalciferol.

    PubMed

    Braithwaite, Miles C; Choonara, Yahya E; Kumar, Pradeep; Tomar, Lomas K; Du Toit, Lisa C; Pillay, Viness

    2016-11-01

    Few researchers have investigated the use of multiple physiological enhancers combined with synthetic carriers to augment delivery of nutraceuticals. The current work describes the development of an oral delivery system termed a bioactive association platform (BAP) capable of delivering nutraceutical actives from a formulation framework specifically for enhancing the in vitro and in vivo performance of model vitamin, cholecalciferol (Vitamin D 3 ). Synthesis of a novel triple vitamin minitablet and an optimized bile salt/lipase alginate-glycerin film provided unique oral components for inclusion in a BAP capsule. Component validation and physicochemical characterizations included comparative ex vivo permeability, chemical structure mapping, thermodynamic analysis and magnetic resonance imaging. In vitro dissolution studies of the BAP produced an area under the dissolution curve (AUC) for cholecalciferol release that was 28% greater than a conventional comparator product. A total of 84.01% of cholecalciferol was released from the BAP within 3 h versus only 59% from a comparator. Ex vivo permeation studies revealed superior cholecalciferol membrane diffusion from the triple vitamin minitablet BAP component. In vivo performance showed a greater mean change from baseline cholecalciferol to peak plasma levels (C max ) from the BAP compared to the comparator (55.66 versus 46.05 ng/mL). Cholecalciferol bioavailability was improved in vivo with an AUC 0-inf from the BAP that was 3.2× greater than the conventional product. The BAP was also superior at improving and maintaining serum levels of the main metabolite, 25-hydroxyvitamin D 3 , compared to the conventional system. In vitro and in vivo results thus confirmed improvements in cholecalciferol dissolution, membrane permeability and plasma drug levels. The study results position the BAP as an ideal oral vehicle for enhanced delivery of cholecalciferol.

  14. Puerarin injection for treatment of unstable angina pectoris: a meta-analysis and systematic review

    PubMed Central

    Gao, Zhisheng; Wei, Baozhu; Qian, Cheng

    2015-01-01

    Background: Puerarin is an effective ingredient isolated from Radix Puerariae, a leguminous plant. In China, a large number of early studies suggest that puerarin may be used in the treatment of coronary heart disease. In recent years, puerarin injection has been widely used to treat coronary heart disease and angina pectoris. Objective: To systematically evaluate the clinical efficacy and safety of puerarin injection in the treatment of unstable angina pectoris (UAP). Methods: Data were retrieved from digital databases, including PubMed, Excerpt Medica Database (EMBASE), China Biology Medicine (CBM), the Cochrane Library, and Chinese databases. Results: Compared with patients who were treated with conventional Western medicines alone, the patients who were treated with conventional Western medicines in combination with puerarin injection exhibited significant improvements in the incidence of angina pectoris, electrocardiogram findings, nitroglycerin consumption and plasma endothelin levels. Conclusions: Strong evidence suggests that, the use of puerarin in combination with conventional Western medicines is a better treatment option for treating UAP, compared with the use of conventional Western medicines alone. PMID:26628941

  15. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  16. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    PubMed

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  17. Health need and the use of alternative medicine among adults who do not use conventional medicine

    PubMed Central

    2010-01-01

    Background We hypothesize that a substantial portion of individuals who forgo conventional care in a given year turn to some form of alternative medicine. This study also examines whether individuals who use only alternative medicine will differ substantially in health and sociodemographic status from individuals using neither alternative medicine nor conventional care in a given year. To identify those factors that predict alternative medicine use in those not using conventional care, we employed the socio-behavioral model of healthcare utilization. Methods The current study is a cross-sectional regression analysis using data from the 2002 National Health Interview Survey. Data were collected in-person from 31,044 adults throughout the 50 states and the District of Columbia. Results 19.3% of adults (38.3 million) did not use conventional care in a 12 month period, although 39.5% of these individuals (14.7 million) reported having one or more problems with their health. Of those not using conventional care, 24.8% (9.5 million) used alternative medicine. Users of alternative medicine had more health needs and were more likely to delay conventional care because of both cost and non-cost factors compared to those not using alternative medicine. While individual predisposing factors (gender, education) were positively associated with alternative medicine use, enabling factors (poverty status, insurance coverage) were not. Conclusions We found that a quarter of individuals who forgo conventional care in a given year turn towards alternative medicine. Our study suggests that the potential determinants of using only alternative medicine are multifactorial. Future research is needed to examine the decision process behind an individual's choice to use alternative medicine but not conventional medicine and the clinical outcomes of this choice. PMID:20670418

  18. Shared and task-specific muscle synergies of Nordic walking and conventional walking.

    PubMed

    Boccia, G; Zoppirolli, C; Bortolan, L; Schena, F; Pellegrini, B

    2018-03-01

    Nordic walking is a form of walking that includes a poling action, and therefore an additional subtask, with respect to conventional walking. The aim of this study was to assess whether Nordic walking required a task-specific muscle coordination with respect to conventional walking. We compared the electromyographic (EMG) activity of 15 upper- and lower-limb muscles of 9 Nordic walking instructors, while executing Nordic walking and conventional walking at 1.3 ms -1 on a treadmill. Non-negative matrix factorization method was applied to identify muscle synergies, representing the spatial and temporal organization of muscle coordination. The number of muscle synergies was not different between Nordic walking (5.2 ± 0.4) and conventional walking (5.0 ± 0.7, P = .423). Five muscle synergies accounted for 91.2 ± 1.1% and 92.9 ± 1.2% of total EMG variance in Nordic walking and conventional walking, respectively. Similarity and cross-reconstruction analyses showed that 4 muscle synergies, mainly involving lower-limb and trunk muscles, are shared between Nordic walking and conventional walking. One synergy acting during upper limb propulsion is specific to Nordic walking, modifying the spatial organization and the magnitude of activation of upper limb muscles compared to conventional walking. The inclusion of the poling action in Nordic walking does not increase the complexity of movement control and does not change the coordination of lower limb muscles. This makes Nordic walking a physical activity suitable also for people with low motor skill. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Utility of Intravascular US-Guided Portal Vein Access during Transjugular Intrahepatic Portosystemic Shunt Creation: Retrospective Comparison with Conventional Technique in 109 Patients.

    PubMed

    Pillai, Anil K; Andring, Brice; Faulconer, Nicholas; Reis, Stephen P; Xi, Yin; Iyamu, Ikponmwosa; Suthpin, Patrick D; Kalva, Sanjeeva P

    2016-08-01

    To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique. In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded. Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004). Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  20. Intensive Hemodialysis Associates with Improved Survival Compared with Conventional Hemodialysis

    PubMed Central

    Lindsay, Robert M.; Cuerden, Meaghan S.; Garg, Amit X.; Port, Friedrich; Austin, Peter C.; Moist, Louise M.; Pierratos, Andreas; Chan, Christopher T.; Zimmerman, Deborah; Lockridge, Robert S.; Couchoud, Cécile; Chazot, Charles; Ofsthun, Norma; Levin, Adeera; Copland, Michael; Courtney, Mark; Steele, Andrew; McFarlane, Philip A.; Geary, Denis F.; Pauly, Robert P.; Komenda, Paul; Suri, Rita S.

    2012-01-01

    Patients undergoing conventional maintenance hemodialysis typically receive three sessions per week, each lasting 2.5–5.5 hours. Recently, the use of more intensive hemodialysis (>5.5 hours, three to seven times per week) has increased, but the effects of these regimens on survival are uncertain. We conducted a retrospective cohort study to examine whether intensive hemodialysis associates with better survival than conventional hemodialysis. We identified 420 patients in the International Quotidian Dialysis Registry who received intensive home hemodialysis in France, the United States, and Canada between January 2000 and August 2010. We matched 338 of these patients to 1388 patients in the Dialysis Outcomes and Practice Patterns Study who received in-center conventional hemodialysis during the same time period by country, ESRD duration, and propensity score. The intensive hemodialysis group received a mean (SD) 4.8 (1.1) sessions per week with a mean treatment time of 7.4 (0.87) hours per session; the conventional group received three sessions per week with a mean treatment time of 3.9 (0.32) hours per session. During 3008 patient-years of follow-up, 45 (13%) of 338 patients receiving intensive hemodialysis died compared with 293 (21%) of 1388 patients receiving conventional hemodialysis (6.1 versus 10.5 deaths per 100 person-years; hazard ratio, 0.55 [95% confidence interval, 0.34–0.87]). The strength and direction of the observed association between intensive hemodialysis and improved survival were consistent across all prespecified subgroups and sensitivity analyses. In conclusion, there is a strong association between intensive home hemodialysis and improved survival, but whether this relationship is causal remains unknown. PMID:22362910

Top