LeBa, Thu-Ba; Gugala, Zbigniew; Morris, Randal P; Panchbhavi, Vinod K
2015-06-01
The purpose of this prospective study was to determine whether gravity versus manual external rotation stress testing effectively detects widening of the medial clear space in isolated ankle fractures when compared with the uninjured contralateral side. Manual external rotation stress and gravity stress tests were performed on injured and uninjured ankles of ankle fracture patients in a clinic setting. Medial clear space measurements were recorded and differences between gravity and manual stress views were determined. Twenty consecutive patients with ankle injury were enrolled in the study. When compared with the uninjured side, gravity stress views showed a statistically significant (P = .017) increase in medial clear space widening (1.85 ± 1.07 mm) compared with manual stress view widening (1.35 ± 1.04 mm). This study suggests that gravity stress views are as effective as manual external rotation stress views in detecting medial clear space widening in isolated fibular fractures. Diagnostic, Level II: Prospective, comparative trial. © 2014 The Author(s).
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-02-01
Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. A comparative study consisting of 50 subjects randomized into two groups - 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94.
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-01-01
Background: Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. Materials & Methods: A comparative study consisting of 50 subjects randomized into two groups – 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Results: Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Conclusions: Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94. PMID:24653610
ERIC Educational Resources Information Center
Lindsay, Gordon B.; Merrill, Ray M.; Owens, Adam; Barleen, Nathan A.
2008-01-01
Background: There is some debate over the efficacy of alcohol industry parenting manuals. Purpose: This study compares the content and focus of alcohol industry and non-industry "talk to your child about drinking" parenting manuals. Methods: Parenting manuals from Anheuser-Busch and Miller Brewing Company were compared to federal government and…
Xhepa, Erion; Byrne, Robert A; Schulz, Stefanie; Helde, Sandra; Gewalt, Senta; Cassese, Salvatore; Linhardt, Maryam; Ibrahim, Tareq; Mehilli, Julinda; Hoppe, Katharina; Grupp, Katharina; Kufner, Sebastian; Böttiger, Corinna; Hoppmann, Petra; Burgdorf, Christof; Fusaro, Massimiliano; Ott, Ilka; Schneider, Simon; Hengstenberg, Christian; Schunkert, Heribert; Laugwitz, Karl-Ludwig; Kastrati, Adnan
2014-06-01
Vascular closure devices (VCD) have been introduced into clinical practice with the aim of increasing the procedural efficiency and clinical safety of coronary angiography. However, clinical studies comparing VCD and manual compression have yielded mixed results, and large randomised clinical trials comparing the two strategies are missing. Moreover, comparative efficacy studies between different VCD in routine clinical use are lacking. The Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial is a prospective, randomised clinical trial designed to compare the outcomes associated with the use of VCD or manual compression to achieve femoral haemostasis. The test hypothesis is that femoral haemostasis after coronary angiography achieved using VCD is not inferior to manual compression in terms of access-site-related vascular complications. Patients undergoing coronary angiography via the common femoral artery will be randomised in a 1:1:1 fashion to receive FemoSeal VCD, EXOSEAL VCD or manual compression. The primary endpoint is the incidence of the composite of arterial access-related complications (haematoma ≥5 cm, pseudoaneurysm, arteriovenous fistula, access-site-related bleeding, acute ipsilateral leg ischaemia, the need for vascular surgical/interventional treatment or documented local infection) at 30 days after randomisation. According to power calculations based on non-inferiority hypothesis testing, enrolment of 4,500 patients is planned. The trial is registered at www.clinicaltrials.gov (study identifier: NCT01389375). The safety of VCD as compared to manual compression in patients undergoing transfemoral coronary angiography remains an issue of clinical equipoise. The aim of the ISAR-CLOSURE trial is to assess whether femoral haemostasis achieved through the use of VCD is non-inferior to manual compression in terms of access-site-related vascular complications.
Update of the Dutch manual for costing studies in health care
Kanters, Tim A.; Bouwmans, Clazien A. M.; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Objectives Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. Methods An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. Results The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. Conclusions The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines. PMID:29121647
Update of the Dutch manual for costing studies in health care.
Kanters, Tim A; Bouwmans, Clazien A M; van der Linden, Naomi; Tan, Siok Swan; Hakkaart-van Roijen, Leona
2017-01-01
Dutch health economic guidelines include a costing manual, which describes preferred research methodology for costing studies and reference prices to ensure high quality studies and comparability between study outcomes. This paper describes the most important revisions of the costing manual compared to the previous version. An online survey was sent out to potential users of the costing manual to identify topics for improvement. The costing manual was aligned with contemporary health economic guidelines. All methodology sections and parameter values needed for costing studies, particularly reference prices, were updated. An expert panel of health economists was consulted several times during the review process. The revised manual was reviewed by two members of the expert panel and by reviewers of the Dutch Health Care Institute. The majority of survey respondents was satisfied with content and usability of the existing costing manual. Respondents recommended updating reference prices and adding some particular commonly needed reference prices. Costs categories were adjusted to the international standard: 1) costs within the health care sector; 2) patient and family costs; and 3) costs in other sectors. Reference prices were updated to reflect 2014 values. The methodology chapter was rewritten to match the requirements of the costing manual and preferences of the users. Reference prices for nursing days of specific wards, for diagnostic procedures and nurse practitioners were added. The usability of the costing manual was increased and parameter values were updated. The costing manual became integrated in the new health economic guidelines.
Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise
2013-06-04
Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study is its generalizability. Future research should address this limitation and may explore alternative approaches to software documentation, such as modular manuals or participatory design.
Manual tracing versus smartphone application (app) tracing: a comparative study.
Sayar, Gülşilay; Kilinc, Delal Dara
2017-11-01
This study aimed to compare the results of conventional manual cephalometric tracing with those acquired with smartphone application cephalometric tracing. The cephalometric radiographs of 55 patients (25 females and 30 males) were traced via the manual and app methods and were subsequently examined with Steiner's analysis. Five skeletal measurements, five dental measurements and two soft tissue measurements were managed based on 21 landmarks. The durations of the performances of the two methods were also compared. SNA (Sella, Nasion, A point angle) and SNB (Sella, Nasion, B point angle) values for the manual method were statistically lower (p < .001) than those for the app method. The ANB value for the manual method was statistically lower than that of app method. L1-NB (°) and upper lip protrusion values for the manual method were statistically higher than those for the app method. Go-GN/SN, U1-NA (°) and U1-NA (mm) values for manual method were statistically lower than those for the app method. No differences between the two methods were found in the L1-NB (mm), occlusal plane to SN, interincisal angle or lower lip protrusion values. Although statistically significant differences were found between the two methods, the cephalometric tracing proceeded faster with the app method than with the manual method.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-07-27
The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.
Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias
2018-03-01
To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-01-01
Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289
Gnjidic, Danijela; Pearson, Sallie-Anne; Hilmer, Sarah N; Basilakis, Jim; Schaffer, Andrea L; Blyth, Fiona M; Banks, Emily
2015-03-30
Increasingly, automated methods are being used to code free-text medication data, but evidence on the validity of these methods is limited. To examine the accuracy of automated coding of previously keyed in free-text medication data compared with manual coding of original handwritten free-text responses (the 'gold standard'). A random sample of 500 participants (475 with and 25 without medication data in the free-text box) enrolled in the 45 and Up Study was selected. Manual coding involved medication experts keying in free-text responses and coding using Anatomical Therapeutic Chemical (ATC) codes (i.e. chemical substance 7-digit level; chemical subgroup 5-digit; pharmacological subgroup 4-digit; therapeutic subgroup 3-digit). Using keyed-in free-text responses entered by non-experts, the automated approach coded entries using the Australian Medicines Terminology database and assigned corresponding ATC codes. Based on manual coding, 1377 free-text entries were recorded and, of these, 1282 medications were coded to ATCs manually. The sensitivity of automated coding compared with manual coding was 79% (n = 1014) for entries coded at the exact ATC level, and 81.6% (n = 1046), 83.0% (n = 1064) and 83.8% (n = 1074) at the 5, 4 and 3-digit ATC levels, respectively. The sensitivity of automated coding for blank responses was 100% compared with manual coding. Sensitivity of automated coding was highest for prescription medications and lowest for vitamins and supplements, compared with the manual approach. Positive predictive values for automated coding were above 95% for 34 of the 38 individual prescription medications examined. Automated coding for free-text prescription medication data shows very high to excellent sensitivity and positive predictive values, indicating that automated methods can potentially be useful for large-scale, medication-related research.
Kour, Amandeep; Kumar, Ashish; Puri, Komal; Khatri, Manish; Bansal, Mansi; Gupta, Geeti
2016-01-01
To compare and evaluate the intra- and inter-examiner efficacy and reproducibility of the first-generation manual (Williams) probe and the third-generation Florida probe in terms of measuring pocket probing depth (PD) and clinical attachment level (CAL). Forty subjects/4000 sites were included in this comparative, cross-sectional study. Group- and site-wise categorizations were done. Based on gingival index, PD, and CAL, patients were divided into four groups, i.e., periodontally healthy, gingivitis, mild to moderate periodontitis, and severe periodontitis. Further, based on these parameters, a total of 4000 sites, with 1000 sites in each category randomly selected from these 40 patients, were taken. Full mouth PD and CAL measurements were recorded with two probes, by Examiner 1 and on Ramfjord teeth by Examiner 2. Full mouth and Ramfjord teeth group- and site-wise PD obtained with the manual probe by both the examiners were statistically significantly deeper than that obtained with the Florida probe. The full mouth and Ramfjord teeth mean CAL measurement by Florida probe was higher as compared to manual probe in mild to moderate periodontitis group and sites, whereas in severe periodontitis group and sites, manual probe recorded higher CAL as compared to Florida probe. Mean PD and CAL measurements were deeper with the manual probe as compared to the Florida probe in all the groups and sites, except for the mild-moderate periodontitis group and sites where the CAL measurements with the manual probe were less than the Florida probe. Manual probe was more reproducible and showed less interexaminer variability as compared to the Florida probe.
Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R.; Lemieux-Charles, Louise
2015-01-01
Research problem Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. Research question What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Literature review Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. Methodology We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. Results and discussion The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study is its generalizability. Future research should address this limitation and may explore alternative approaches to software documentation, such as modular manuals or participatory design. PMID:26190888
Wong, M S; Cheng, J C Y; Wong, M W; So, S F
2005-04-01
A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.
Masa, Juan F; Corral, Jaime; Pereira, Ricardo; Duran-Cantolla, Joaquin; Cabello, Marta; Hernández-Blasco, Luis; Monasterio, Carmen; Alonso-Fernandez, Alberto; Chiner, Eusebi; Vázquez-Polo, Francisco-José; Montserrat, Jose M
2013-04-01
Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.
Comparative Costs of Manual and On-line Bibliographic Searching: A Review of the Literature.
ERIC Educational Resources Information Center
East, H.
1980-01-01
A review of published studies reveals that the cost of comparable manual and online searches are approximately equal. Cost trends and the relative effectiveness of both methods are evaluated. A bibliography of 51 references is appended. (Author/RAA)
Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Garg, Shailesh; Hori, Masatoshi; Oto, Aytekin; Baron, Richard L.
2014-01-01
OBJECTIVE The purpose of this study was to evaluate automated CT volumetry in the assessment of living-donor livers for transplant and to compare this technique with software-aided interactive volumetry and manual volumetry. MATERIALS AND METHODS Hepatic CT scans of 18 consecutively registered prospective liver donors were obtained under a liver transplant protocol. Automated liver volumetry was developed on the basis of 3D active-contour segmentation. To establish reference standard liver volumes, a radiologist manually traced the contour of the liver on each CT slice. We compared the results obtained with automated and interactive volumetry with those obtained with the reference standard for this study, manual volumetry. RESULTS The average interactive liver volume was 1553 ± 343 cm3, and the average automated liver volume was 1520 ± 378 cm3. The average manual volume was 1486 ± 343 cm3. Both interactive and automated volumetric results had excellent agreement with manual volumetric results (intraclass correlation coefficients, 0.96 and 0.94). The average user time for automated volumetry was 0.57 ± 0.06 min/case, whereas those for interactive and manual volumetry were 27.3 ± 4.6 and 39.4 ± 5.5 min/case, the difference being statistically significant (p < 0.05). CONCLUSION Both interactive and automated volumetry are accurate for measuring liver volume with CT, but automated volumetry is substantially more efficient. PMID:21940543
Suzuki, Kenji; Epstein, Mark L; Kohlbrenner, Ryan; Garg, Shailesh; Hori, Masatoshi; Oto, Aytekin; Baron, Richard L
2011-10-01
The purpose of this study was to evaluate automated CT volumetry in the assessment of living-donor livers for transplant and to compare this technique with software-aided interactive volumetry and manual volumetry. Hepatic CT scans of 18 consecutively registered prospective liver donors were obtained under a liver transplant protocol. Automated liver volumetry was developed on the basis of 3D active-contour segmentation. To establish reference standard liver volumes, a radiologist manually traced the contour of the liver on each CT slice. We compared the results obtained with automated and interactive volumetry with those obtained with the reference standard for this study, manual volumetry. The average interactive liver volume was 1553 ± 343 cm(3), and the average automated liver volume was 1520 ± 378 cm(3). The average manual volume was 1486 ± 343 cm(3). Both interactive and automated volumetric results had excellent agreement with manual volumetric results (intraclass correlation coefficients, 0.96 and 0.94). The average user time for automated volumetry was 0.57 ± 0.06 min/case, whereas those for interactive and manual volumetry were 27.3 ± 4.6 and 39.4 ± 5.5 min/case, the difference being statistically significant (p < 0.05). Both interactive and automated volumetry are accurate for measuring liver volume with CT, but automated volumetry is substantially more efficient.
Does the use of automated fetal biometry improve clinical work flow efficiency?
Espinoza, Jimmy; Good, Sara; Russell, Evie; Lee, Wesley
2013-05-01
This study was designed to compare the work flow efficiency of manual measurements of 5 fetal parameters with a novel technique that automatically measures these parameters from 2-dimensional sonograms. This prospective study included 200 singleton pregnancies between 15 and 40 weeks' gestation. Patients were randomly allocated to either manual (n = 100) or automatic (n = 100) fetal biometry. The automatic measurement was performed using a commercially available software application. A digital video recorder captured all on-screen activity associated with the sonographic examination. The examination time and number of steps required to obtain fetal measurements were compared between manual and automatic methods. The mean time required to obtain the biometric measurements was significantly shorter using the automated technique than the manual approach (P < .001 for all comparisons). Similarly, the mean number of steps required to perform these measurements was significantly fewer with automatic measurements compared to the manual technique (P < .001). In summary, automated biometry reduced the examination time required for standard fetal measurements. This approach may improve work flow efficiency in busy obstetric sonography practices.
Automobile driver fatalities in frontal impacts: air bags compared with manual belts.
Zador, P L; Ciccone, M A
1993-01-01
OBJECTIVES. The effectiveness of air bags was estimated in this study by comparing driver fatalities in frontal crashes with driver fatalities in nonfrontal crashes, for cars with air bags and manual belts and cars with manual belts only. METHODS. Fatal Accident Reporting System data for drivers fatally injured during 1985 to 1991 in 1985 to 1991 model year cars that were equipped with air bags in or before model year 1991 were analyzed. RESULTS. Driver fatalities in frontal crashes in air bag cars were 28% lower than those in comparable cars with manual belts only. This percentage was used for estimating the overall fatality reduction in air bag cars. The reduction was greater in large cars (50%) than in midsize cars (19%) or in small cars (14%). Air bags reduced driver fatalities in frontal crashes involving ejection by about 9%. Fatalities in frontal crashes among drivers who were reportedly using manual belts at the time of the crash were reduced by about 15%. The comparable reduction among drivers who were reportedly not using manual belts was 31%. CONCLUSION. It was estimated that air bags reduced the total number of all driver fatalities by about 19%. PMID:8484445
Kawamura, Mitsuharu; Scheinman, Melvin M; Tseng, Zian H; Lee, Byron K; Marcus, Gregory M; Badhwar, Nitish
2017-01-01
Catheter ablation for idiopathic ventricular arrhythmia (VA) is effective and safe, but efficacy is frequently limited due to an epicardial origin and difficult anatomy. The remote magnetic navigation (RMN) catheter has a flexible catheter design allowing access to difficult anatomy. We describe the efficacy of the RMN for ablation of idiopathic VA after failed manual ablation. Among 235 patients with idiopathic VA referred for catheter ablation, we identified 51 patients who were referred for repeat ablation after a failed manual ablation. We analyzed the clinical characteristics, including the successful ablation site and findings at electrophysiology study, in repeat procedures conducted using RMN as compared with manual ablation. Among these patients, 22 (43 %) underwent repeat ablation with the RMN and 29 (57 %) underwent repeat ablation with a manual ablation. Overall, successful ablation rate was significantly higher using RMN as compared with manual ablation (91 vs. 69 %, P = 0.02). Fluoroscopy time in the RMN was 17 ± 12 min as compared with 43 ± 18 min in the manual ablation (P = 0.009). Successful ablation rate in the posterior right ventricular outflow tract (RVOT) plus posterior-tricuspid annulus was higher with RMN as compared with manual ablation (92 vs. 50 %, P = 0.03). Neither groups exhibited any major complications. The RMN is more effective in selected patients with recurrent idiopathic VA after failed manual ablation and is associated with less fluoroscopy time. The RMN catheters have a flexible design enabling them to access otherwise difficult anatomy including the posterior tricuspid annulus and posterior RVOT.
Burgmans, Mark Christiaan; den Harder, J Michiel; Meershoek, Philippa; van den Berg, Nynke S; Chan, Shaun Xavier Ju Min; van Leeuwen, Fijs W B; van Erkel, Arian R
2017-06-01
To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.
NASA Astrophysics Data System (ADS)
Lizarelli, Rosane F. Z.; Ferreira, Zulene A.; Torquato, Tatiana M.; Sampaio, Jose E. C.; Bagnato, Vanderlei S.
2000-03-01
One of the most important difficulty in the periodontal disease treatment resides in the impossibility of decontamination of roots just affected by the periodontal disease through mechanical tools. Manual dental scaling results in the amorphous material without continuity solution due to the dental cut, denominated smear layer. The main purpose of the present study was to evaluate the structure of the radicular surface using two methods for periodontal treatments: manual and mechanical associated to the irrigation with water and with EDTA (ethylene diamine tetracycline acid), followed by the application of the Er:YAG laser or the same without laser. Thirty teeth were selected with periodontal involvement. The radicular surface was scraped with ultrasound and planed vigorously, with manual instrumentation. The teeth were divided ramdomically in several groups: GI -- control, just manual instrumentation and water irrigation; GII -- manual instrumentation, EDTA irrigation; GIII -- manual instrumentation, EDTA irrigation, Er:YAG laser irradiation; GIV -- manual instrumentation, laser irradiation; and, GV -- manual instrumentation, laser irradiation and EDTA. Kruskall Wallis statistical test was applied and shows that there was not significance difference at the level of 5% among the five groups, however, when the groups were compared in pairs, GII X GIV and GII X GV shows difference in 5%, and GI X GII, difference at 1% level. The results show equivalence around the used methodology.
Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe
2011-03-01
This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.
Guimaraes, Carolina V; Grzeszczuk, Robert; Bisset, George S; Donnelly, Lane F
2018-03-01
When implementing or monitoring department-sanctioned standardized radiology reports, feedback about individual faculty performance has been shown to be a useful driver of faculty compliance. Most commonly, these data are derived from manual audit, which can be both time-consuming and subject to sampling error. The purpose of this study was to evaluate whether a software program using natural language processing and machine learning could accurately audit radiologist compliance with the use of standardized reports compared with performed manual audits. Radiology reports from a 1-month period were loaded into such a software program, and faculty compliance with use of standardized reports was calculated. For that same period, manual audits were performed (25 reports audited for each of 42 faculty members). The mean compliance rates calculated by automated auditing were then compared with the confidence interval of the mean rate by manual audit. The mean compliance rate for use of standardized reports as determined by manual audit was 91.2% with a confidence interval between 89.3% and 92.8%. The mean compliance rate calculated by automated auditing was 92.0%, within that confidence interval. This study shows that by use of natural language processing and machine learning algorithms, an automated analysis can accurately define whether reports are compliant with use of standardized report templates and language, compared with manual audits. This may avoid significant labor costs related to conducting the manual auditing process. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan
2014-05-01
In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of pulmonary overdistention, while decreasing the ventilation rate.
Sun, Jennifer K.; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W.; Andreoli, Christopher M.; Edwards, Paul A.; Glassman, Adam R.; Pavlica, Michael R.
2012-01-01
Objective To compare visual acuity (VA) scores after autorefraction versus research protocol manual refraction in eyes of patients with diabetes and a wide range of VA. Methods Electronic Early Treatment Diabetic Retinopathy Study (E-ETDRS) VA Test© letter score (EVA) was measured after autorefraction (AR-EVA) and after Diabetic Retinopathy Clinical Research Network (DRCR.net) protocol manual refraction (MR-EVA). Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA utilizing an identical manual refraction (MR-EVAsupl) was performed to determine test-retest variability. Results In 878 eyes of 456 study participants, median MR-EVA was 74 (Snellen equivalent approximately 20/32). Spherical equivalent was often similar for manual and autorefraction (median difference: 0.00, 5th and 95th percentiles −1.75 to +1.13 Diopters). However, on average, MR-EVA results were slightly better than AR-EVA results across the entire VA range. Furthermore, variability between AR-EVA and MR-EVA was substantially greater than the test-retest variability of MR-EVA (P<0.001). Variability of differences was highly dependent on autorefractor model. Conclusions Across a wide range of VA at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models comparing most favorably to manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA. PMID:22159173
Software-assisted small bowel motility analysis using free-breathing MRI: feasibility study.
Bickelhaupt, Sebastian; Froehlich, Johannes M; Cattin, Roger; Raible, Stephan; Bouquet, Hanspeter; Bill, Urs; Patak, Michael A
2014-01-01
To validate a software prototype allowing for small bowel motility analysis in free breathing by comparing it to manual measurements. In all, 25 patients (15 male, 10 female; mean age 39 years) were included in this Institutional Review Board-approved, retrospective study. Magnetic resonance imaging (MRI) was performed on a 1.5T system after standardized preparation acquiring motility sequences in free breathing over 69-84 seconds. Small bowel motility was analyzed manually and with the software. Functional parameters, measurement time, and reproducibility were compared using the coefficient of variance and paired Student's t-test. Correlation was analyzed using Pearson's correlation coefficient and linear regression. The 25 segments were analyzed twice both by hand and using the software with automatic breathing correction. All assessed parameters significantly correlated between the methods (P < 0.01), but the scattering of repeated measurements was significantly (P < 0.01) lower using the software (3.90%, standard deviation [SD] ± 5.69) than manual examinations (9.77%, SD ± 11.08). The time needed was significantly less (P < 0.001) with the software (4.52 minutes, SD ± 1.58) compared to manual measurement, lasting 17.48 minutes for manual (SD ± 1.75 minutes). The use of the software proves reliable and faster small bowel motility measurements in free-breathing MRI compared to manual analyses. The new technique allows for analyses of prolonged sequences acquired in free breathing, improving the informative value of the examinations by amplifying the evaluable data. Copyright © 2013 Wiley Periodicals, Inc.
Semiautomated spleen volumetry with diffusion-weighted MR imaging.
Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu
2012-07-01
In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.
Meshram, GK
2010-01-01
ABSTRACT Aim : To assess the cleaning efficacy of manual and automated instrumentation using 4% sodium hypochlorite singly and in combination with Glyde file Prep as root canal irrigant. Methodology : The study utilized 40 extracted human permanent premolars with single, straight and fully formed root. The teeth were then divided into four groups of ten each, Group I and II were prepared by manual instruments with 4% sodium hypochlorite used as irrigant singly [Group I] or in combination with Glyde file prep. Group III and IV were prepared by automated instruments at 250 rpm with 4% sodium hypochlorite as irrigant singly [Group III] and in combination with glyde file prep [Group IV] automated instrumentation. After completion of the root canal preparation the canal, teeth were prepared for SEM examination. These photomicrographs were qualitatively evaluated using criteria. Overall cleanliness, presence or absence of the smear layer, presence or absence of the debris, patency of the opening of dentinal tubules. Results : When comparing the cleansing efficacy of manual and automated instrumentation using 4% sodium hypochlorite better cleansing was there with manual instrumentation. When comparing the cleansing efficacy of manual and automated instrumentation using combination regime cleansing is better with automated instrumentation. When comparing the cleansing efficacy of manual instrumentation using 4% sodium hypochlorite singly and in combination with EDTA, the combination regime led to better cleansing. When comparing the cleansing efficacy of automated instrumentation using 4% sodium hypochlorite singly and in combination regime lead to better cleansing. Conclusion : Neither of instrumentation technique, nor irrigating regimes were capable of providing a completely clean canal. Automated instrumentation with a combination of sodium hypochlorite & EDTA resulted the best cleansing efficacy. PMID:27616839
Cox, Daniel J; Punja, Mohan; Powers, Katie; Merkel, R Lawrence; Burket, Roger; Moore, Melissa; Thorndike, Frances; Kovatchev, Boris
2006-11-01
Inattention is a major contributor to driving mishaps and is especially problematic among adolescent drivers with ADHD, possibly contributing to their 2 to 4 times higher incidence of collisions. Manual transmission has been demonstrated to be associated with greater arousal. This study tests the hypotheses that manual transmission, compared to automatic transmission, would be associated with better attention and performance on a driving simulator. Ten adolescent drivers with ADHD practice driving on the simulator in the manual and automatic mode. Employing a single-blind, cross-over design, participants drive the simulator at 19:30 and 22:30 hr for 30 min in both transmissions and rate their attention to driving. Subjectively, participants report being more attentive while driving in manual transmission mode. Objectively, participants drive safer in the manual transmission mode. Although in need of replication, this pilot study suggests a behavioral intervention to improve driving performance among ADHD adolescents.
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
Xu, Qinguang; Chen, Bei; Wang, Yueyi; Wang, Xuezong; Han, Dapeng; Ding, Daofang; Zheng, Yuxin; Cao, Yuelong; Zhan, Hongsheng; Zhou, Yao
2017-05-01
Knee osteoarthritis (KOA) is the most common form of arthritis, leading to pain disability in seniors and increased health care utilization. Manual therapy is one widely used physical treatment for KOA. To evaluate the effectiveness and adverse events (AEs) of manual therapy compared to other treatments for relieving pain, stiffness, and physical dysfunction in patients with KOA. A systematic review and meta-analysis of manual therapy for KOA. We searched PubMed, EMBASE, the Cochrane Library, and Chinese databases for relevant randomized controlled trials (RCTs) of manual therapy for patients with KOA from the inception to October 2015 without language restrictions. RCTs compared manual therapy to the placebo or other interventional control with an appropriate description of randomization. Two reviewers independently conducted the search results identification, data extraction, and methodological quality assessment. The methodological quality was assessed by PEDro scale. Pooled data was expressed as standard mean difference (SMD), with 95% confident intervals (CIs) in a random effects model. The meta-analysis of manual therapy for KOA on pain, stiffness, and physical function were conducted. Fourteen studies involving 841 KOA participants compared to other treatments were included. The methodological quality of most included RCTs was poor. The mean PEDro scale score was 6.6. The meta-analyses results showed that manual therapy had statistically significant effects on relieving pain (standardized mean difference, SMD = -0.61, 95% CI -0.95 to -0.28, P = 76%), stiffness (SMD = -0.58, 95% CI -0.95 to -0.21, P = 81%), improving physical function (SMD = -0.49, 95% CI -0.76 to -0.22, P = 65%), and total score (SMD = -0.56, 95% CI -0.78 to -0.35, P = 50%). But in the subgroups, manual therapy did not show significant improvements on stiffness and physical function when treatment duration was less than 4 weeks. And the long-term information for manual therapy was insufficient. The limitations of this systematic review include the paucity of literature and inevitable heterogeneity between included studies. The preliminary evidence from our study suggests that manual therapy might be effective and safe for improving pain, stiffness, and physical function in KOA patients and could be treated as complementary and alternative options. However, the evidence may be limited by potential bias and poor methodological quality of included studies. High-quality RCTs with long-term follow-up are warranted to confirm our findings.Key words: Knee osteoarthritis, manual therapy, systematic review.
Taenzer, Andreas H; Pyke, Joshua; Herrick, Michael D; Dodds, Thomas M; McGrath, Susan P
2014-02-01
The manual collection and charting of traditional vital signs data in inpatient populations have been shown to be inaccurate when compared with true physiologic values. This issue has not been examined with respect to oxygen saturation data despite the increased use of this measurement in systems designed to assess the risk of patient deterioration. Of particular note are the lack of available data examining the accuracy of oxygen saturation charting in a particularly vulnerable group of patients who have prolonged oxygen desaturations (mean SpO2 <90% over at least 15 minutes). In addition, no data are currently available that investigate the often suspected "wake up" effect, resulting from a nurse entering a patient's room to obtain vital signs. In this study, we compared oxygen saturation data recorded manually with data collected by an automated continuous monitoring system in 16 inpatients considered to be at high risk for deterioration (average SpO2 values <90% collected by the automated system in a 15-minute interval before a manual charting event). Data were sampled from the automatic collection system from 2 periods: over a 15-minute period that ended 5 minutes before the time of the manual data collection and charting, and over a 5-minute range before and after the time of the manual data collection and charting. Average saturations from prolonged baseline desaturations (15-minute period) were compared with both the manual and automated data sampled at the time of the nurse's visit to analyze for systematic change and to investigate the presence of an arousal effect. The manually charted data were higher than those recorded by the automated system. Manually recorded data were on average 6.5% (confidence interval, 4.0%-9.0%) higher in oxygen saturation. No significant arousal effect resulting from the nurse's visit to the patient's room was detected. In a cohort of patients with prolonged desaturations, manual recordings of SpO2 did not reflect physiologic patient state when compared with continuous automated sampling. Currently, early warning scores depend on manual vital sign recordings in many settings; the study data suggest that SpO2 ought to be added to the list of vital sign values that have been shown to be recorded inaccurately.
Wong, M T P; Ho, T P; Ho, M Y; Yu, C S; Wong, Y H; Lee, S Y
2002-05-01
The Geriatric Depression Scale (GDS) is a common screening tool for elderly depression in Hong Kong. This study aimed at (1) developing a standardized manual for the verbal administration and scoring of the GDS-SF, and (2) comparing the inter-rater reliability between the standardized and non-standardized verbal administration of GDS-SF. Two studies were reported. In Study 1, the process of developing the manual was described. In Study 2, we compared the inter-rater reliabilities of GDS-SF scores using the standardized verbal instructions and the traditional non-standardized administration. Results of Study 2 indicated that the standardized procedure in verbal administration and scoring improved the inter-rater reliabilities of GDS-SF. Copyright 2002 John Wiley & Sons, Ltd.
Manual rotation to decrease operative delivery in posterior or transverse positions.
Le Ray, Camille; Deneux-Tharaux, Catherine; Khireddine, Imane; Dreyfus, Michel; Vardon, Delphine; Goffinet, François
2013-09-01
To assess the effect of a policy of manual rotation on the mode of delivery of fetuses in posterior or transverse positions at full dilatation. This was a prospective study to compare two policies of management for posterior and transverse positions in two different hospitals (Hospital 1: no manual rotation and Hospital 2: manual rotation). We used univariable and multivariable analyses to study the association between the management policy for posterior and transverse positions at full dilatation in these hospitals and maternal and neonatal outcomes. The principal end point was operative delivery (ie, cesarean or instrumental vaginal delivery). All factors associated with the risk of operative delivery in the univariable analysis (P<.1) were included in the logistic regression models. We then specifically studied whether manual rotation was independently associated with a reduction in operative deliveries. The rate of posterior or transverse positions at full dilatation was 15.9% (n=111) in Hospital 1 and 15.3% (n=220) in Hospital 2 (P=.75). Of the 172 attempts of manual rotation in Hospital 2, 155 (90.1%) were successful. The rate of operative delivery was significantly lower in Hospital 2, which performed manual rotations (23.2% compared with 38.7% in Hospital 1, adjusted odds ratio [OR] 0.52, 95% confidence interval [CI] 0.28-0.95). After multivariable analysis, manual rotation remained significantly associated with a reduction in the risk of operative delivery (adjusted OR 0.45, 95% CI 0.25-0.85). Five-minute Apgar score and arterial pH at birth were similar in the two hospitals. For fetuses in posterior or transverse positions at full dilatation, a strategy of manual rotation is associated with a reduction in the rate of operative delivery. III.
Wong, M S; Cheng, J C Y; Lo, K H
2005-04-01
The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl
PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined bymore » measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.« less
A randomized controlled trial testing the efficacy of an HIV/AIDS symptom management manual.
Wantland, Dean J; Holzemer, William L; Moezzi, Shahnaz; Willard, Suzanne S; Arudo, John; Kirksey, Kenn M; Portillo, Carmen J; Corless, Inge B; Rosa, María E; Robinson, Linda L; Nicholas, Patrice K; Hamilton, Mary Jane; Sefcik, Elizabeth F; Human, Sarie; Rivero, Marta M; Maryland, Mary; Huang, Emily
2008-09-01
This study investigates whether using an HIV/AIDS symptom management manual with self-care strategies for 21 common symptoms, compared to a basic nutrition manual, had an effect on reducing symptom frequency and intensity. A 775-person, repeated measures, randomized controlled trial was conducted over three months in 12 sites from the United States, Puerto Rico, and Africa to assess the relationship between symptom intensity with predictors for differences in initial symptom status and change over time. A mixed model growth analysis showed a significantly greater decline in symptom frequency and intensity for the group using the symptom management manual (intervention) compared to those using the nutrition manual (control) (t=2.36, P=0.018). The models identified three significant predictors for increased initial symptom intensities and in intensity change over time: (1) protease inhibitor-based therapy (increased mean intensity by 28%); (2) having comorbid illness (nearly twice the mean intensity); and (3) being Hispanic receiving care in the United States (increased the mean intensity by 2.5 times). In addition, the symptom manual showed a significantly higher helpfulness rating and was used more often compared to the nutrition manual. The reduction in symptom intensity scores provides evidence of the need for palliation of symptoms in individuals with HIV/AIDS, as well as symptoms and treatment side effects associated with other illnesses. The information from this study may help health care providers become more aware of self-management strategies that are useful to persons with HIV/AIDS and help them to assist patients in making informed choices.
Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
Kolokitha, Olga-Elpis
2007-01-01
Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468
Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.
Kolokitha, Olga-Elpis
2007-10-01
The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.
Holte, H H; Tambs, K; Bjerkedal, T
2000-06-01
Manual work is reported to be a risk factor for becoming a disability pensioner due to osteoarthritis. This association may be due to covariation with other variables. We wanted to assess if manual work remained a risk factor after adjusting for number of hours worked, income, level of education, gender and marital status, and if the risk associated with manual work was equal in the 1970s and the 1980s. In a prospective study, data on all new disability pensioners with osteoarthritis in Norway during the two follow-up periods, 1971-1980 and 1981-1990, were analysed by logistic regression. The study include data on all subjects living in Norway and registered as 50-56 years old and employed either in the census collected in 1970 or in the census of 1980. Manual workers have nearly twice the probability of becoming a disability pensioner with osteoarthritis compared to professionals after adjusting for part-time work, income, level of education, marital status and gender. Adjusted for other risk factors, the probability of becoming a disability pensioner with osteoarthritis was three times higher in the 1980s compared to the 1970s. The relatively strong association between manual work and disability pensioning with osteoarthritis suggests difficulties in adjusting manual work patterns for a person with osteoarthritis, which may have increased during the study period as implied by the separate effect of the 1980s.
Dehmel, Carola; Braune, Stephan A; Kreymann, Georg; Baehr, Michael; Langebrake, Claudia; Hilgarth, Heike; Nierhaus, Axel; Dartsch, Dorothee C; Kluge, Stefan
2011-08-01
To compare the concentration conformity of infusion solutions manually prepared on intensive care units (ICU) with solutions from pharmacy-based, automated production. A prospective observational study conducted in a university hospital in Germany. Drug concentrations of 100 standardised infusion solutions manually prepared in the ICU and 100 matching solutions from automated production containing amiodarone, noradrenaline or hydrocortisone were measured by high-performance liquid chromatography analysis. Deviations from stated concentrations were calculated, and the quality of achieved concentration conformity of the two production methods was compared. Actual concentrations of 53% of the manually prepared and 16% of the machine-made solutions deviated by >5% above or below the stated concentration. A deviation of >10% was measured in 22% of the manually prepared samples and in 5% of samples from automated production. Of the manually prepared solutions, 15% deviated by >15% above or below the intended concentration. The mean concentration of the manually prepared solutions was 97.2% (SD 12.7%, range 45-129%) and of the machine-made solutions was 101.1% (SD 4.3%, range 90-114%) of the target concentration (p < 0.01). In this preliminary study, ward-based, manually prepared infusion solutions showed clinically relevant deviations in concentration conformity significantly more often than pharmacy-prepared, machine-made solutions. Centralised, automated preparation of standardised infusion solutions may be an effective means to reduce this type of medication error. Further confirmatory studies in larger settings and under conditions of routine automated production are required.
More on the Effects of Early Manual Communication on the Cognitive Development of Deaf Children.
ERIC Educational Resources Information Center
Zwiebel, Abraham
1987-01-01
A study compared intelligence scores of three groups of Israeli deaf children--23 with deaf parents/deaf siblings and manual communication (DpDs), 76 with hearing parents/deaf siblings, and 144 with hearing parents and siblings. The DpDs children were superior to other deaf children and comparable to hearing children on most intelligence measures.…
Microprocessor-controlled hemodynamics: a step towards improved efficiency and safety.
Keogh, B E; Jacobs, J; Royston, D; Taylor, K M
1989-02-01
Manual titration of sodium nitroprusside (SNP) is widely used for treatment of hypertension following cardiac surgery. This study compared conventional manual control with control by a research prototype of an automatic infusion module based on a proportional plus integral plus derivative (PID) negative feedback loop. Two groups of coronary artery bypass patients requiring SNP for postoperative hypertension were studied prospectively. In the first group, hypertension was controlled by manual adjustment of the SNP infusion rate, and in the second, the infusion rate was controlled automatically. The actual and desired mean arterial pressures (MAP) over consecutive ten-second epochs were recorded during the period of infusion. The MAP was maintained within 10% of the desired MAP 45.8% of the time in the manual group, compared with 90.0% in the automatic group, and the mean percent error in the automatic group was significantly less than in the manual group (P less than 0.01). It is concluded that adoption of such systems will result in improved patient safety and may facilitate more effective distribution of nursing staff within intensive care units.
Sun, Jennifer K; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W; Andreoli, Christopher M; Edwards, Paul A; Glassman, Adam R; Pavlica, Michael R
2012-04-01
To compare visual acuity (VA) scores after autorefraction vs manual refraction in eyes of patients with diabetes mellitus and a wide range of VAs. The letter score from the Electronic Visual Acuity (EVA) test from the electronic Early Treatment Diabetic Retinopathy Study was measured after autorefraction (AR-EVA score) and after manual refraction (MR-EVA score), which is the research protocol of the Diabetic Retinopathy Clinical Research Network. Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA test using an identical supplemental manual refraction (MR-EVAsuppl score) was performed to determine test-retest variability. In 878 eyes of 456 study participants, the median MR-EVA score was 74 (Snellen equivalent, approximately 20/32). The spherical equivalent was often similar for manual refraction and autorefraction (median difference, 0.00; 5th-95th percentile range, -1.75 to 1.13 diopters). However, on average, the MR-EVA scores were slightly better than the AR-EVA scores, across the entire VA range. Furthermore, the variability between the AR-EVA scores and the MR-EVA scores was substantially greater than the test-retest variability of the MR-EVA scores (P < .001). The variability of differences was highly dependent on the autorefractor model. Across a wide range of VAs at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models that compare most favorably with manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that, with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA.
Comparative study of Sperm Motility Analysis System and conventional microscopic semen analysis
KOMORI, KAZUHIKO; ISHIJIMA, SUMIO; TANJAPATKUL, PHANU; FUJITA, KAZUTOSHI; MATSUOKA, YASUHIRO; TAKAO, TETSUYA; MIYAGAWA, YASUSHI; TAKADA, SHINGO; OKUYAMA, AKIHIKO
2006-01-01
Background and Aim: Conventional manual sperm analysis still shows variations in structure, process and outcome although World Health Organization (WHO) guidelines present an appropriate method for sperm analysis. In the present study a new system for sperm analysis, Sperm Motility Analysis System (SMAS), was compared with manual semen analysis based on WHO guidelines. Materials and methods: Samples from 30 infertility patients and 21 healthy volunteers were subjected to manual microscopic analysis and SMAS analysis, simultaneously. We compared these two methods with respect to sperm concentration and percent motility. Results: Sperm concentrations obtained by SMAS (Csmas) and manual microscopic analyses on WHO guidelines (Cwho) were strongly correlated (Cwho = 1.325 × Csmas; r = 0.95, P < 0.001). If we excluded subjects with Csmas values >30 × 106 sperm/mL, the results were more similar (Cwho = 1.022 × Csmas; r = 0.81, P < 0.001). Percent motility obtained by SMAS (Msmas) and manual analysis on WHO guidelines (Mwho) were strongly correlated (Mwho = 1.214 × Msmas; r = 0.89, P < 0.001). Conclusions: The data indicate that the results of SMAS and those of manual microscopic sperm analyses based on WHO guidelines are strongly correlated. SMAS is therefore a promising system for sperm analysis. (Reprod Med Biol 2006; 5: 195–200) PMID:29662398
Semi-automating the manual literature search for systematic reviews increases efficiency.
Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald
2010-03-01
To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.
Fananapazir, Ghaneh; Bashir, Mustafa R; Marin, Daniele; Boll, Daniel T
2015-06-01
To evaluate the performance of a prototype, fully-automated post-processing solution for whole-liver and lobar segmentation based on MDCT datasets. A polymer liver phantom was used to assess accuracy of post-processing applications comparing phantom volumes determined via Archimedes' principle with MDCT segmented datasets. For the IRB-approved, HIPAA-compliant study, 25 patients were enrolled. Volumetry performance compared the manual approach with the automated prototype, assessing intraobserver variability, and interclass correlation for whole-organ and lobar segmentation using ANOVA comparison. Fidelity of segmentation was evaluated qualitatively. Phantom volume was 1581.0 ± 44.7 mL, manually segmented datasets estimated 1628.0 ± 47.8 mL, representing a mean overestimation of 3.0%, automatically segmented datasets estimated 1601.9 ± 0 mL, representing a mean overestimation of 1.3%. Whole-liver and segmental volumetry demonstrated no significant intraobserver variability for neither manual nor automated measurements. For whole-liver volumetry, automated measurement repetitions resulted in identical values; reproducible whole-organ volumetry was also achieved with manual segmentation, p(ANOVA) 0.98. For lobar volumetry, automated segmentation improved reproducibility over manual approach, without significant measurement differences for either methodology, p(ANOVA) 0.95-0.99. Whole-organ and lobar segmentation results from manual and automated segmentation showed no significant differences, p(ANOVA) 0.96-1.00. Assessment of segmentation fidelity found that segments I-IV/VI showed greater segmentation inaccuracies compared to the remaining right hepatic lobe segments. Automated whole-liver segmentation showed non-inferiority of fully-automated whole-liver segmentation compared to manual approaches with improved reproducibility and post-processing duration; automated dual-seed lobar segmentation showed slight tendencies for underestimating the right hepatic lobe volume and greater variability in edge detection for the left hepatic lobe compared to manual segmentation.
Gonçalves, Antonio José; de Souza, J A L; Menezes, M B; Kavabata, N K; Suehara, A B; Lehn, C N
2009-11-01
The extension of the surgery and closure type of the pharynx can be the determinants in the pharyngocutaneous fistula development. The objective of the study is to evaluate the incidence of pharingocutaneous salivary fistulae after total laryngectomies comparing manual and mechanical sutures. The study is designed as non-randomized, prospective clinical study. Sixty patients with squamous cell carcinoma were submitted to total laryngectomies. In 30 cases, the linear stapler (75 mm) closure (surgical technique described in details) and in other 30 cases manual suture was used. The cases of mechanical suture were prospective and consecutive and the cases of manual suture were a review series of patients who underwent a manual suture of pharynx, in the same period of time. The statistical analysis between the two groups concluded that both were comparable. Fistulae incidence was 6.7% (2/30) in the group with the mechanical suture and 36.7% (11/30) in the group with manual suture closure, presenting a significant difference (p = 0.0047). The total laryngectomy with mechanical closure is an easy and fast learning technique, allowing watertight closure of the pharynx with a low risk of contamination of the surgical field. It is an assured method, even in previously irradiated patients, since we respect the limits of its indication regarding the extension of primary tumor that must be confirmed by previous suspension laryngectomy performed in the operating room.
Attitudes of College Freshmen toward Bibliographic Instruction.
ERIC Educational Resources Information Center
Leighton, Gordon B.; Markman, Marsha C.
1991-01-01
Reports on a study which evaluated student attitudes toward a new bibliographic instruction (BI) manual designed to address their individual needs and compares the results with those of previous studies on BI methods, i.e., lecture and discussion practicum versus a self-guided workbook. It is concluded that the new manual is regarded more…
Yaffe, Mark; Luo, Michael; Goyal, Nitin; Chan, Philip; Patel, Anay; Cayo, Max; Stulberg, S David
2014-09-01
The purpose of this study was to evaluate clinical, functional, and radiographic outcomes following total knee arthroplasty (TKA) performed with patient-specific instrumentation (PSI), computer-assisted surgery (CAS), and manual instruments at short-term follow-up. 122 TKAs were performed by a single surgeon: 42 with PSI, 38 with CAS, and 40 with manual instrumentation. Preoperative, 1-month, and 6-month clinical and functional outcomes were measured using the Knee Society scoring system (knee score, function score, range of motion, and pain score). Improvements in clinical and functional outcomes from the preoperative to postoperative period were analyzed. Preoperative and postoperative radiographs were measured to evaluate limb and component alignment. Preoperative, 1-month postoperative, and 6-month postoperative knee scores, function scores, range of motion, and pain scores were highest in the PSI group compared to CAS and manual instrumentation. At 6-month follow-up, PSI TKA was associated with a statistically significant improvement in functional score when compared to manual TKA. Otherwise, there were no statistically significant differences in improvements among PSI, CAS, and manual TKA groups. The higher preoperative scores in the PSI group limits the ability to draw definitive conclusions from the raw postoperative scores, but analyzing the changes in scores revealed that PSI was associated with a statistically significant improvement in Knee Society Functional score at 6-month post-TKA as compared to CAS or manual TKA. This may be attributable to improvements in component rotation and positioning, improved component size accuracy, or other factors that are not discernible on plain radiograph.
ERIC Educational Resources Information Center
Oliveira, Marileide; Goyos, Celso; Pear, Joseph
2012-01-01
Matching-to-sample (MTS) training consists of presenting a stimulus as a sample followed by stimuli called comparisons from which a subject makes a choice. This study presents results of a pilot investigation comparing two packages for teaching university students to conduct MTS training. Two groups--control and experimental--with 2 participants…
Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon
2011-01-01
The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornelis, F.; Takaki, H.; Laskhmanan, M.
PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less
Plaque reduction over time of an integrated oral hygiene system.
Nunn, Martha E; Ruhlman, C Douglas; Mallatt, Philip R; Rodriguez, Sally M; Ortblad, Katherine M
2004-10-01
This article compares the efficacy of a prototype integrated system (the IntelliClean System from Sonicare and Crest) in the reduction of supragingival plaque to that of a manual toothbrush and conventional toothpaste. The integrated system was compared to a manual toothbrush with conventional toothpaste in a randomized, single-blinded, parallel, 4-week, controlled clinical trial with 100 subjects randomized to each treatment group. There was a low dropout rate, with 89 subjects in the manual toothbrush group (11% loss to follow-up) and 93 subjects in the integrated system group (7% loss to follow-up) completing the study. The Turesky modification of the Quigley and Hein Plaque Index was used to assess full-mouth plaque scores for each subject. Prebrushing plaque scores were obtained at baseline and at 4 weeks after 14 to 20 hours of plaque accumulation. A survey also was conducted at the conclusion of the study to determine the attitude toward the two oral hygiene systems. The integrated system was found to significantly reduce overall and interproximal prebrushing plaque scores over 4 weeks, both by 8.6%, demonstrating statistically significant superiority in overall plaque reduction (P = .002) and interproximal plaque reduction (P < .001) compared to the manual toothbrush with conventional toothpaste, which showed no significant reduction in either overall plaque or interproximal plaque. This study demonstrates that the IntelliClean System from Sonicare and Crest is superior to a manual toothbrush with conventional toothpaste in reducing overall plaque and interproximal plaque over time.
Prophylactic antibiotics for manual removal of retained placenta in vaginal birth.
Chongsomchai, Chompilas; Lumbiganon, Pisake; Laopaiboon, Malinee
2014-10-20
Retained placenta is a potentially life-threatening condition because of its association with postpartum hemorrhage. Manual removal of placenta increases the likelihood of bacterial contamination in the uterine cavity. To compare the effectiveness and side-effects of routine antibiotic use for manual removal of placenta in vaginal birth in women who received antibiotic prophylaxis and those who did not and to identify the appropriate regimen of antibiotic prophylaxis for this procedure. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 July 2014). All randomized controlled trials comparing antibiotic prophylaxis and placebo or non antibiotic use to prevent endometritis after manual removal of placenta in vaginal birth. There are no included trials. In future updates, if we identify eligible trials, two review authors will independently assess trial quality and extract data No studies that met the inclusion criteria were identified. There are no randomized controlled trials to evaluate the effectiveness of antibiotic prophylaxis to prevent endometritis after manual removal of placenta in vaginal birth.
Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon
2013-05-01
The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
Bizzarri, Paolo; Buzzatti, Luca; Cattrysse, Erik; Scafoglieri, Aldo
2018-02-01
Manual treatments targeting different regions (shoulder, cervical spine, thoracic spine, ribs) have been studied to deal with patients complaining of shoulder pain. Thoracic manual treatments seem able to produce beneficial effects on this group of patients. However, it is not clear whether the patient improvement is a consequence of thoracic manual therapy or a placebo effect. To compare the efficacy of thoracic manual therapy and placebo thoracic manual treatment for patients with shoulder dysfunction. Electronic databases (MEDLINE, CENTRAL, PEDro, CINAHL, WoS, EMBASE, ERIC) were searched through November 2016. Randomized Controlled Trials assessing pain, mobility and function were selected. The Cochrane bias estimation tool was applied. Outcome results were either extracted or computed from raw data. Meta-analysis was performed for outcomes with low heterogeneity. Four studies were included in the review. The methodology of the included studies was generally good except for one study that was rated as high risk of bias. Meta-analysis showed no significant effect for "pain at present" (SMD -0.02; 95% CI: -0.35, 0.32) and "pain during movement" (SMD -0.12; 95% CI: -0.45, 0.21). There is very low to low quality of evidence that a single session of thoracic manual therapy is not more effective than a single session of placebo thoracic manual therapy in patients with shoulder dysfunction at immediate post-treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
The contribution of major diagnostic causes to socioeconomic differences in disability retirement.
Polvinen, Anu; Laaksonen, Mikko; Gould, Raija; Lahelma, Eero; Martikainen, Pekka
2014-07-01
The aim of this study was twofold: to investigate socioeconomic differences in disability retirement (DR) due to major diseases and find out which diseases contribute most to the overall socioeconomic differences in DR. The data were longitudinal register-based (10% sample of Finns) from Statistics Finland. These data included 258 428 participants aged 35-64 years during the follow-up. The participants were employed or unemployed before the follow-up period 1997-2010. Of all participants, 14 303 men and 13 188 women ended up in DR during the follow-up. Socioeconomic status was categorized into upper- and lower-class non-manual employees, manual workers, and self-employed persons. Cox models were used to estimate hazard ratios for DR due to different diseases. Compared to upper-class non-manual employees, DR was especially high for manual workers whose retirement diagnoses included psychoactive substance use, musculoskeletal diseases (MSD), or cardiovascular diseases. Socioeconomic differences in DR were stronger for younger age groups and men versus women. For females and males, the largest part of the excess DR among manual workers compared to upper-class non-manual employees was due to MSD. In the age group 54-64 years, the contribution of MSD to the total excess was >50% among male manual workers and 75% among female manual workers. Excess DR due to mental disorders concerned only 35-54-year-old manual workers (among 23% men and 26% women). The contribution of MSD to the total excess DR among lower socioeconomic groups was large. Prevention of MSD among manual workers would likely reduce socioeconomic differences in DR.
Shin, Byung-Cheul; Kim, Me-Riong; Cho, Jae-Heung; Jung, Jae-Young; Kim, Koh-Woon; Lee, Jun-Hwan; Nam, Kibong; Lee, Min Ho; Hwang, Eui-Hyoung; Heo, Kwang-Ho; Kim, Namkwen; Ha, In-Hyuk
2017-01-17
While Chuna manual therapy is a Korean manual therapy widely used primarily for low back pain (LBP)-related disorders in Korea, well-designed studies on the comparative effectiveness of Chuna manual therapy are scarce. This study is the protocol for a three-armed, multicenter, pragmatic randomized controlled pilot trial. Sixty severe nonacute LBP patients (pain duration of at least 3 weeks, Numeric Rating Scale (NRS) ≥5) will be recruited at four Korean medicine hospitals. Participants will be randomly allocated to the Chuna group (n = 20), usual care group (n = 20), or Chuna plus usual care group (n = 20) for 6 weeks of treatment. Usual care will consist of orally administered conventional medicine, physical therapy, and back pain care education. The trial will be conducted with outcome assessor and statistician blinding. The primary endpoint will be NRS of LBP at week 7 post randomization. Secondary outcomes include NRS of leg pain, the Oswestry Disability Index (ODI), the Patient Global Impression of Change (PGIC), the Credibility and Expectancy Questionnaire, lumbar range of motion (ROM), the EuroQol-5 Dimension (EQ-5D) health survey, the Health Utility Index III (HUI-III), and economic evaluation and safety data. Post-treatment follow-ups will be conducted at 1, 4, and 10 weeks after conclusion of treatment. This study will assess the comparative effectiveness of Chuna manual therapy compared to conventional usual care. Costs and effectiveness (utility) data will be analyzed for exploratory cost-effectiveness analysis. If this pilot study does not reach a definite conclusion due to its small sample size, these results will be used as preliminary results to calculate sample size for future large-scale clinical trials and contribute in the assessment of feasibility of a full-scale multicenter trial. Clinical Research Information Service (CRIS), KCT0001850 . Registered on 17 March 2016.
Buescher, D L; Möllers, M; Falkenberg, M K; Amler, S; Kipp, F; Burdach, J; Klockenbusch, W; Schmitz, R
2016-05-01
Transvaginal and intracavitary ultrasound probes are a possible source of cross-contamination with microorganisms and thus a risk to patients' health. Therefore appropriate methods for reprocessing are needed. This study was designed to compare the standard disinfection method for transvaginal ultrasound probes in Germany with an automated disinfection method in a clinical setting. This was a prospective randomized controlled clinical study of two groups. In each group, 120 microbial samples were collected from ultrasound transducers before and after disinfection with either an automated method (Trophon EPR®) or a manual method (Mikrozid Sensitive® wipes). Samples were then analyzed for microbial growth and isolates were identified to species level. Automated disinfection had a statistically significantly higher success rate of 91.4% (106/116) compared with 78.8% (89/113) for manual disinfection (P = 0.009). The risk of contamination was increased by 2.9-fold when disinfection was performed manually (odds ratio, 2.9 (95% CI, 1.3-6.3)). Before disinfection, bacterial contamination was observed on 98.8% of probes. Microbial analysis revealed 36 different species of bacteria, including skin and environmental bacteria as well as pathogenic bacteria such as Staphylococcus aureus, enterobacteriaceae and Pseudomonas spp. Considering the high number of contaminated probes and bacterial species found, disinfection of the ultrasound probe's body and handle should be performed after each use to decrease the risk of cross-contamination. This study favored automated disinfection owing to its significantly higher efficacy compared with a manual method. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Koehl, Bérengère; Sommet, Julie; Holvoet, Laurent; Abdoul, Hendy; Boizeau, Priscilla; Ithier, Ghislaine; Missud, Florence; Couque, Nathalie; Verlhac, Suzanne; Voultoury, Pauline; Sellami, Fatiha; Baruchel, André; Benkerrou, Malika
2016-05-01
Chronic exchange transfusion is effective for primary and secondary prevention of stroke in children with sickle cell anemia (SCA). Erythrocytapheresis is recognized to be the most efficient approach; however, it is not widely implemented and is not suitable for all patients. The aim of our study was to compare automated exchange transfusion (AET) with our manual method of exchange transfusion and, in particular, to evaluate the efficacy, safety, and cost of our manual method. Thirty-nine SCA children with stroke and/or abnormal findings on transcranial Doppler were included in the study. We retrospectively analyzed 1353 exchange sessions, including 333 sessions of AET and 1020 sessions of manual exchange transfusion (MET). Both methods were well tolerated. The median decrease in hemoglobin (Hb)S per session was 21.5% with AET and 18.8% with our manual method (p < 0.0001) with no major increase in red blood cell consumption. Iron overload was well controlled, even with the manual method, with a median (interquartile range) ferritin level of 312 (152-994) µg/L after 24 months of transfusions. The main differences in annual cost relate to equipment costs, which were 74 times higher with the automated method. Our study shows that continuous MET has comparable efficacy to the automated method in terms of stroke prevention, decrease in HbS, and iron overload prevention. It is feasible in all hospital settings and is often combined with AET successively over time. © 2016 AABB.
Miller, Daniel L; Roy, Sanjoy; Kassis, Edmund S; Yadalam, Sashi; Ramisetti, Sushama; Johnston, Stephen S
2018-05-01
Video-assisted thoracic surgery (VATS) lung resections are complex procedures with a critical role played by endoscopic staplers in the transection of vessels, bronchi, and lung tissue. This retrospective, observational study compared hospital resource use, costs, and complications of VATS lobectomy procedures for whom powered versus manual endoscopic surgical staplers were used. Patients ≥ 18 years of age undergoing elective VATS lobectomy during an inpatient admission from January 1, 2012 to September 30, 2016 were identified from the Premier Healthcare Database (first admission = index admission). Use of either powered or manual endoscopic staplers during the index admission was identified from hospital administrative records. Multivariable regression analyses adjusting for patient, hospital, and provider characteristics and hospital-level clustering were carried out to compare the following outcomes between the powered and manual stapler groups: hospital length of stay (LOS), operating room time (ORT), hospital costs, complications (bleeding and/or transfusions, air leak complications, pneumonia, and infection), discharge status, and 30-, 60-, and 90-day all-cause readmissions. The powered and manual stapler groups comprised 659 patients (mean age 66.1 years; 53.6% female) and 3100 patients (mean age 66.7 years; 54.8% female), respectively. In the multivariable analyses, the powered stapler group had shorter LOS (4.9 vs. 5.9 days, P < 0.001), lower total hospital costs ($23,841 vs. $26,052, P = 0.009), and lower rates of combined hemostasis complications (bleeding and/or transfusions; 8.5% vs. 16.0%, P < 0.001) and transfusions (5.4% vs. 10.9%, P = 0.002), compared with the manual stapler group. Other outcomes did not differ significantly between the study groups. Similar trends were observed in subanalyses comparing devices across predominant manufacturers in each group, and in subanalyses of patients with comorbid chronic obstructive pulmonary disease. In this analysis of VATS lobectomy procedures, powered staplers were associated with significant benefits with respect to selected types of hospital resource use, costs, and clinical outcomes when compared with manual staplers. Johnson & Johnson.
Tele-Manipulation with Two Asymmetric Slaves: Two Operators Perform Better Than One.
van Oosterhout, Jeroen; Heemskerk, Cock J M; de Baar, Marco R; van der Helm, Frans C T; Abbink, David A
2018-01-01
Certain tele-manipulation tasks require manipulation by two asymmetric slaves, for example, a crane for hoisting and a dexterous robotic arm for fine manipulation. It is unclear how to best design human-in-the-loop control over two asymmetric slaves. The goal of this paper is to quantitatively compare the standard approach of two co-operating operators that each control a single subtask, to a single operator performing bi-manual control over the two subtasks, and a uni-manual control approach. In a human factors experiment, participants performed a heavy load maneuvering and mounting task using a vertical crane and a robotic arm. We hypothesize that bi-manual control yields worse task performance and control activity compared to co-operation, because of conflicting spatial and temporal constraints. Literature suggests that uni-manual operators should perform better than co-operation, as co-operators critically depend on each other's actions. However, other literature provides evidence that individual operators have limited capabilities in controlling asymmetric axes of two dynamic systems. The results show that the two co-operators perform the maneuvering and mounting task faster than either bi- or uni-manual operators. Compared to co-operators, uni-manual operators required more control activity for the vertical crane and less for the robotic arm. In conclusion, this study suggests that when controlling two asymmetric slaves, a co-operating pair of operators performs better than a single operator.
Gomes-Neto, Mansueto; Lopes, Jordana Moura; Conceição, Cristiano Sena; Araujo, Anderson; Brasileiro, Alécio; Sousa, Camila; Carvalho, Vitor Oliveira; Arcanjo, Fabio Luciano
2017-01-01
We performed a systematic review with a meta-analysis to examine the efficacy of stabilization exercises versus general exercises or manual therapy in patients with low back pain. We searched MEDLINE, Cochrane Controlled Trials, Scielo, and CINAHL (from the earliest date available to November 2014) for randomized controlled trials that examined the efficacy of stabilization exercises compared to general exercises or manual therapy on pain, disability, and function in patients with low back pain. Weighted mean differences (WMD) and 95% confidence intervals were calculated. Eleven studies met the inclusion criteria (413 stabilization exercises patients, 297 general exercises patients, and 185 manual therapy patients). Stabilization exercises may provide greater benefit than general exercise for pain reduction and improvement in disability. Stabilization exercise improved pain with a WMD of -1.03 (95% CI: -1.29 to -0.27) and improved disability with a WMD of -5.41 (95% CI: -8.34 to -2.49). There were no significant differences in pain and disability scores among participants in the stabilization exercise group compared to those in the manual therapy group. Stabilization exercises were as efficacious as manual therapy in decreasing pain and disability and should be encouraged as part of musculoskeletal rehabilitation for low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Péterffy, A; Calabrese, E
1979-01-01
A U.S.-made TA-30 model stapling device was utilized to close the bronchial stump in 146 patients, while conventional manual suturing with chromic catgut was performed for the same purpose in 152 patients. The two groups were comparable in respect of pre-operative status and operative diagnosis. Patients, in whom the stapler was utilized, showed a decreased incidence of bronchial fistula (1% vs. 3%) and empyema without fistula (1% vs. 3%). The stapler, compared with conventional manual sutures, allows a simpler and swifter suture of the bronchial stump, reduces the contamination of the operative field, achieves uniform and tighter closure of the bronchus, leaves a better preserved terminal blood perfusion of the stump and utilizes a more tolerated sewing material with less resultant tissue inflammation.
Klapsing, Philipp; Herrmann, Peter; Quintel, Michael; Moerer, Onnen
2017-12-01
Quantitative lung computed tomographic (CT) analysis yields objective data regarding lung aeration but is currently not used in clinical routine primarily because of the labor-intensive process of manual CT segmentation. Automatic lung segmentation could help to shorten processing times significantly. In this study, we assessed bias and precision of lung CT analysis using automatic segmentation compared with manual segmentation. In this monocentric clinical study, 10 mechanically ventilated patients with mild to moderate acute respiratory distress syndrome were included who had received lung CT scans at 5- and 45-mbar airway pressure during a prior study. Lung segmentations were performed both automatically using a computerized algorithm and manually. Automatic segmentation yielded similar lung volumes compared with manual segmentation with clinically minor differences both at 5 and 45 mbar. At 5 mbar, results were as follows: overdistended lung 49.58mL (manual, SD 77.37mL) and 50.41mL (automatic, SD 77.3mL), P=.028; normally aerated lung 2142.17mL (manual, SD 1131.48mL) and 2156.68mL (automatic, SD 1134.53mL), P = .1038; and poorly aerated lung 631.68mL (manual, SD 196.76mL) and 646.32mL (automatic, SD 169.63mL), P = .3794. At 45 mbar, values were as follows: overdistended lung 612.85mL (manual, SD 449.55mL) and 615.49mL (automatic, SD 451.03mL), P=.078; normally aerated lung 3890.12mL (manual, SD 1134.14mL) and 3907.65mL (automatic, SD 1133.62mL), P = .027; and poorly aerated lung 413.35mL (manual, SD 57.66mL) and 469.58mL (automatic, SD 70.14mL), P=.007. Bland-Altman analyses revealed the following mean biases and limits of agreement at 5 mbar for automatic vs manual segmentation: overdistended lung +0.848mL (±2.062mL), normally aerated +14.51mL (±49.71mL), and poorly aerated +14.64mL (±98.16mL). At 45 mbar, results were as follows: overdistended +2.639mL (±8.231mL), normally aerated 17.53mL (±41.41mL), and poorly aerated 56.23mL (±100.67mL). Automatic single CT image and whole lung segmentation were faster than manual segmentation (0.17 vs 125.35seconds [P<.0001] and 10.46 vs 7739.45seconds [P<.0001]). Automatic lung CT segmentation allows fast analysis of aerated lung regions. A reduction of processing times by more than 99% allows the use of quantitative CT at the bedside. Copyright © 2016 Elsevier Inc. All rights reserved.
Mans, Christoph; Guzman, David Sanchez-Migallon; Lahner, Lesanna L; Paul-Murphy, Joanne; Sladky, Kurt K
2012-09-01
Administration of intranasal midazolam (2 mg/kg) was evaluated for sedation and effects on cloacal temperature, respiratory rate, and heart rate in manually restrained Hispaniolan Amazon parrots (Amazona ventralis). Adult parrots (n=9) were administered either midazolam (2 mg/kg) or an equal volume of saline solution intranasally before a 15-minute manual restraint in a complete crossover study. Respiratory rate and sedation scores were recorded before and during capture and during and after 15 minutes of manual restraint. Heart rate and cloacal temperature were recorded during manual restraint. After restraint, the parrots received intranasal flumazenil (0.05 mg/kg) or an equal volume of saline solution, and the recovery time was recorded. In those birds that received midazolam, sedation was observed within 3 minutes of administration, and vocalization, flight, and defense responses were significantly reduced during capture. During manual restraint, the mean rate of cloacal temperature increase was significantly slower and remained significantly lower in birds that received midazolam compared with controls. Mean respiratory rates were significantly lower for up to 12 minutes in parrots that received midazolam compared with those receiving saline solution. Flumazenil antagonized the effects of midazolam within 10 minutes. No overt clinical adverse effects to intranasal midazolam and flumazenil administration were observed. Further studies on the safety of intranasal midazolam and flumazenil in this species are warranted.
Tsertsvadze, Alexander; Clar, Christine; Court, Rachel; Clarke, Aileen; Mistry, Hema; Sutcliffe, Paul
2014-01-01
The purpose of this study was to systematically review trial-based economic evaluations of manual therapy relative to other alternative interventions used for the management of musculoskeletal conditions. A comprehensive literature search was undertaken in major medical, health-related, science and health economic electronic databases. Twenty-five publications were included (11 trial-based economic evaluations). The studies compared cost-effectiveness and/or cost-utility of manual therapy interventions to other treatment alternatives in reducing pain (spinal, shoulder, ankle). Manual therapy techniques (e.g., osteopathic spinal manipulation, physiotherapy manipulation and mobilization techniques, and chiropractic manipulation with or without other treatments) were more cost-effective than usual general practitioner (GP) care alone or with exercise, spinal stabilization, GP advice, advice to remain active, or brief pain management for improving low back and shoulder pain/disability. Chiropractic manipulation was found to be less costly and more effective than alternative treatment compared with either physiotherapy or GP care in improving neck pain. Preliminary evidence from this review shows some economic advantage of manual therapy relative to other interventions used for the management of musculoskeletal conditions, indicating that some manual therapy techniques may be more cost-effective than usual GP care, spinal stabilization, GP advice, advice to remain active, or brief pain management for improving low back and shoulder pain/disability. However, at present, there is a paucity of evidence on the cost-effectiveness and/or cost-utility evaluations for manual therapy interventions. Further improvements in the methodological conduct and reporting quality of economic evaluations of manual therapy are warranted in order to facilitate adequate evidence-based decisions among policy makers, health care practitioners, and patients. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Performance of an Automated Versus a Manual Whole-Body Magnetic Resonance Imaging Workflow.
Stocker, Daniel; Finkenstaedt, Tim; Kuehn, Bernd; Nanz, Daniel; Klarhoefer, Markus; Guggenberger, Roman; Andreisek, Gustav; Kiefer, Berthold; Reiner, Caecilia S
2018-04-24
The aim of this study was to evaluate the performance of an automated workflow for whole-body magnetic resonance imaging (WB-MRI), which reduces user interaction compared with the manual WB-MRI workflow. This prospective study was approved by the local ethics committee. Twenty patients underwent WB-MRI for myopathy evaluation on a 3 T MRI scanner. Ten patients (7 women; age, 52 ± 13 years; body weight, 69.9 ± 13.3 kg; height, 173 ± 9.3 cm; body mass index, 23.2 ± 3.0) were examined with a prototypical automated WB-MRI workflow, which automatically segments the whole body, and 10 patients (6 women; age, 35.9 ± 12.4 years; body weight, 72 ± 21 kg; height, 169.2 ± 10.4 cm; body mass index, 24.9 ± 5.6) with a manual scan. Overall image quality (IQ; 5-point scale: 5, excellent; 1, poor) and coverage of the study volume were assessed by 2 readers for each sequence (coronal T2-weighted turbo inversion recovery magnitude [TIRM] and axial contrast-enhanced T1-weighted [ce-T1w] gradient dual-echo sequence). Interreader agreement was evaluated with intraclass correlation coefficients. Examination time, number of user interactions, and MR technicians' acceptance rating (1, highest; 10, lowest) was compared between both groups. Total examination time was significantly shorter for automated WB-MRI workflow versus manual WB-MRI workflow (30.0 ± 4.2 vs 41.5 ± 3.4 minutes, P < 0.0001) with significantly shorter planning time (2.5 ± 0.8 vs 14.0 ± 7.0 minutes, P < 0.0001). Planning took 8% of the total examination time with automated versus 34% with manual WB-MRI workflow (P < 0.0001). The number of user interactions with automated WB-MRI workflow was significantly lower compared with manual WB-MRI workflow (10.2 ± 4.4 vs 48.2 ± 17.2, P < 0.0001). Planning efforts were rated significantly lower by the MR technicians for the automated WB-MRI workflow than for the manual WB-MRI workflow (2.20 ± 0.92 vs 4.80 ± 2.39, respectively; P = 0.005). Overall IQ was similar between automated and manual WB-MRI workflow (TIRM: 4.00 ± 0.94 vs 3.45 ± 1.19, P = 0.264; ce-T1w: 4.20 ± 0.88 vs 4.55 ± .55, P = 0.423). Interreader agreement for overall IQ was excellent for TIRM and ce-T1w with an intraclass correlation coefficient of 0.95 (95% confidence interval, 0.86-0.98) and 0.88 (95% confidence interval, 0.70-0.95). Incomplete coverage of the thoracic compartment in the ce-T1w sequence occurred more often in the automated WB-MRI workflow (P = 0.008) for reader 2. No other significant differences in the study volume coverage were found. In conclusion, the automated WB-MRI scanner workflow showed a significant reduction of the examination time and the user interaction compared with the manual WB-MRI workflow. Image quality and the coverage of the study volume were comparable in both groups.
Hemispheric Preference and Cyclic Variation of Solar Filament Chirality
NASA Astrophysics Data System (ADS)
Hazra, Soumitra; Mahajan, Sushant S.; Douglas, William; Martens, Petrus C.
2017-08-01
Although the hemispheric preference of magnetic topological features in the solar atmosphere is a well-established fact, strength and cyclic variation of the hemispheric rule is a debatable issue. In this work, we study the chirality of 3480 solar filaments from 2000 to 2016. We determine the chirality of filaments manually and compare with the results obtained from the Advanced Automated Filament Detection and Characterization Code (AAFDCC). We find that 83% of our manually determined filaments follow the hemispheric chirality rule, while 58% of automatically determined filamentsfollow the same. We also compare our result with an other manually compiled list by Pevtsov et al. (2003). We find that our list matches Pevtsovs manually compiled list with 90% accuracy. We also find that the hemispheric chirality rule does not vary from cycle to cycle. However, the strength of the hemispheric preference decreases at the end and beginning phase of the solar cycle.
Consumers' use of written product information.
Wiese, Bettina S; Sauer, Jürgen; Rüttinger, Bruno
2004-09-15
Two studies were conducted to investigate the predictive role of person-specific, product-specific, and situation-specific influences on the use of instruction manuals in the field of electrical consumer products. In a laboratory study, 42 participants were observed while putting a vacuum cleaner into operation. Situational primes (i.e., receiving a verbal cue that the packaging contains an instruction manual) increased the probability of the user manual being read. Additional verbal information that the manual contains information on energy-saving behaviours was especially motivating for persons with high environmental concern. Self-report data, collected on a wide range of products, suggest that product complexity is the best predictor of instruction manual use. In a second study with 30 participants, different positions of product labels were compared, i.e. placing the information on the packaging or directly onto the product. Information placed directly onto the product had a significantly higher influence on participants' actual behaviour than providing the same information on the packaging.
Seat belt use in cars with air bags.
Williams, A F; Wells, J K; Lund, A K
1990-01-01
Seat belt use was observed in 1,628 cars with air bags and manual belts and 34,223 cars with manual seat belts only. Sixty-six percent of drivers in cars with air bags wore seat belts compared to 63 percent of drivers in cars with manual belts only. The study found no evidence for the speculation that drivers with air bags will reduce their seat belt use because they believe an air bag alone provides sufficient protection. PMID:2240346
Gender incongruence: a comparative study using ICD-10 and DSM-5 diagnostic criteria.
Soll, Bianca M; Robles-García, Rebeca; Brandelli-Costa, Angelo; Mori, Daniel; Mueller, Andressa; Vaitses-Fontanari, Anna M; Cardoso-da-Silva, Dhiordan; Schwarz, Karine; Abel-Schneider, Maiko; Saadeh, Alexandre; Lobato, Maria-Inês-Rodrigues
2018-01-01
To compare the presence of criteria listed in the DSM-5 and ICD-10 diagnostic manuals in a Brazilian sample of transgender persons seeking health services specifically for physical transition. This multicenter cross-sectional study included a sample of 103 subjects who sought services for gender identity disorder in two main reference centers in Brazil. The method involved a structured interview encompassing the diagnostic criteria in the two manuals. The results revealed that despite theoretical disagreement about the criteria, the manuals overlap regarding diagnosis confirmation; the DSM-5 was more inclusive (97.1%) than the ICD-10 (93.2%) in this population. Although there is no consensus on diagnostic criteria on transgenderism in the diversity of social and cultural contexts, more comprehensive diagnostic criteria are evolving due to society's increasing inclusivity.
Kam, M H; Tang, C L; Chan, E; Lim, J F; Eu, K W
2009-09-01
A systematic review was conducted to determine if manual decompression is a safe alternative to intraoperative colonic irrigation prior to primary anastomosis in obstructed left-sided colorectal emergencies. Search for relevant articles from 1980 to 2007 was conducted on Medline, Embase and the Cochrane Controlled Trials Register using the keywords "colonic lavage, irrigation, decompression, washout, obstructed and bowel preparation", either singularly or in combination. Trials in English publications with similar patient characteristics, inclusion criteria and outcome measures were selected for analysis. Thirty-day mortality, anastomotic leak rates and post-operative wound infection were studied as outcome variables. Analysis was performed with RevMan 4.2 software. Seven trials were identified for systematic review, with a total of 449 patients. Data from the single randomised controlled trial and one prospective comparative trial were analysed separately. Results from the remaining five studies were pooled into two arms of a composite series, one with colonic irrigation and one without. Results showed no significant difference in the anastomotic leak rates and mortality rates between the colonic irrigation and manual decompression arms in the randomised and comparative trials. The composite series, however, showed significantly better results with manual decompression (RR 6.18, 95% CI 1.67-22.86). The post-operative infection rate was similar in both groups. Manual decompression was comparable to colonic irrigation for primary anastomosis in obstructed left-sided colorectal emergencies, with no significant increase in mortality, leak or infection rates.
A study of emergency American football helmet removal techniques.
Swartz, Erik E; Mihalik, Jason P; Decoster, Laura C; Hernandez, Adam E
2012-09-01
The purpose was to compare head kinematics between the Eject Helmet Removal System and manual football helmet removal. This quasi-experimental study was conducted in a controlled laboratory setting. Thirty-two certified athletic trainers (sex, 19 male and 13 female; age, 33 ± 10 years; height, 175 ± 12 cm; mass, 86 ± 20 kg) removed a football helmet from a healthy model under 2 conditions: manual helmet removal and Eject system helmet removal. A 6-camera motion capture system recorded 3-dimensional head position. Our outcome measures consisted of the average angular velocity and acceleration of the head in each movement plane (sagittal, frontal, and transverse), the resultant angular velocity and acceleration, and total motion. Paired-samples t tests compared each variable across the 2 techniques. Manual helmet removal elicited greater average angular velocity in the sagittal and transverse planes and greater resultant angular velocity compared with the Eject system. No differences were observed in average angular acceleration in any single plane of movement; however, the resultant angular acceleration was greater during manual helmet removal. The Eject Helmet Removal System induced greater total head motion. Although the Eject system created more motion at the head, removing a helmet manually resulted in more sudden perturbations as identified by resultant velocity and acceleration of the head. The implications of these findings relate to the care of all cervical spine-injured patients in emergency medical settings, particularly in scenarios where helmet removal is necessary. Copyright © 2012 Elsevier Inc. All rights reserved.
Rickmann, Annekatrin; Opitz, Natalia; Szurman, Peter; Boden, Karl Thomas; Jung, Sascha; Wahl, Silke; Haus, Arno; Damm, Lara-Jil; Januschowski, Kai
2018-01-01
Descemet membrane endothelial keratoplasty (DMEK) has been improved over the last decade. The aim of this study was to compare the clinical outcome of the recently introduced liquid bubble method compared to the standard manual preparation. This retrospective study evaluated the outcome of 200 patients after DMEK surgery using two different graft preparation techniques. Ninety-six DMEK were prepared by manual dissection and 104 by the novel liquid bubble technique. The mean follow-up time was 13.7 months (SD ± 8, range 6-36 months). Best corrected mean visual acuity (BCVA) increased for all patients statistically significant from baseline 0.85 logMAR (SD ± 0.5) to 0.26 logMAR (SD ± 0.27) at the final follow-up (Wilcoxon, p = 0.001). Subgroup analyses of BCVA at the final follow-up between manual dissection and liquid bubble preparation showed no statistically significant difference (Mann-Whitney U Test, p = 0.64). The mean central corneal thickness was not statistically different (manual dissection: 539 µm, SD ± 68 µm and liquid bubble technique: 534 µm, SD ± 52 µm,) between the two groups (Mann-Whitney U Test, p = 0.64). At the final follow-up, mean endothelial cell count of donor grafts was statistically not significant different at the final follow-up with 1761 cells/mm 2 (-30.7%, SD ± 352) for manual dissection compared to liquid bubble technique with 1749 cells/mm 2 (-29.9%, SD ± 501) (Mann-Whitney U-Test, p = 0.73). The re-DMEK rate was comparable for manual dissection with 8 cases (8.3%) and 7 cases (6.7%) for liquid bubble dissection (p = 0.69, Chi-Square Test). Regarding the clinical outcome, we did not find a statistical significant difference between manual dissection and liquid bubble graft preparation. Both preparation techniques lead to an equivalent clinical outcome after DMEK surgery.
End-tidal CO2-guided automated robot CPR system in the pig. Preliminary communication.
Suh, Gil Joon; Park, Jaeheung; Lee, Jung Chan; Na, Sang Hoon; Kwon, Woon Yong; Kim, Kyung Su; Kim, Taegyun; Jung, Yoon Sun; Ko, Jung-In; Shin, So Mi; You, Kyoung Min
2018-06-01
Our aim was to compare the efficacy of the end-tidal CO 2 -guided automated robot CPR (robot CPR) system with manual CPR and mechanical device CPR. We developed the algorithm of the robot CPR system which automatically finds the optimal compression position under the guidance of end-tidal CO 2 feedback in swine models of cardiac arrest. Then, 18 pigs after 11 min of cardiac arrest were randomly assigned to one of three groups, robot CPR, LUCAS CPR, and manual CPR groups (n = 6 each group). Return of spontaneous circulation (ROSC) and Neurological Deficit Score 48 h after ROSC were compared. A ROSC was achieved in 5 pigs, 4 pigs, and 3 pigs in the robot CPR, LUCAS CPR, and manual CPR groups, respectively (p = 0.47). Robot CPR showed a significant difference in Neurological Deficit Score 48 h after ROSC compared to manual CPR, whereas LUCAS CPR showed no significant difference over manual CPR. (p = 0.01; Robot versus Manual adjusted p = 0.04, Robot versus LUCAS adjusted p = 0.07, Manual versus LUCAS adjusted p = 1.00). The end-tidal CO 2 -guided automated robot CPR system did not significantly improve ROSC rate in a swine model of cardiac arrest. However, robot CPR showed significant improvement of Neurological Deficit Score 48 h after ROSC compared to Manual CPR while LUCAS CPR showed no significant improvement compared to Manual CPR. Copyright © 2018 Elsevier B.V. All rights reserved.
Benefits of Manometer in Non-Invasive Ventilatory Support.
Lacerda, Rodrigo Silva; de Lima, Fernando Cesar Anastácio; Bastos, Leonardo Pereira; Fardin Vinco, Anderson; Schneider, Felipe Britto Azevedo; Luduvico Coelho, Yves; Fernandes, Heitor Gomes Costa; Bacalhau, João Marcus Ramos; Bermudes, Igor Matheus Simonelli; da Silva, Claudinei Ferreira; da Silva, Luiza Paterlini; Pezato, Rogério
2017-12-01
Introduction Effective ventilation during cardiopulmonary resuscitation (CPR) is essential to reduce morbidity and mortality rates in cardiac arrest. Hyperventilation during CPR reduces the efficiency of compressions and coronary perfusion. Problem How could ventilation in CPR be optimized? The objective of this study was to evaluate non-invasive ventilator support using different devices. The study compares the regularity and intensity of non-invasive ventilation during simulated, conventional CPR and ventilatory support using three distinct ventilation devices: a standard manual resuscitator, with and without airway pressure manometer, and an automatic transport ventilator. Student's t-test was used to evaluate statistical differences between groups. P values <.05 were regarded as significant. Peak inspiratory pressure during ventilatory support and CPR was significantly increased in the group with manual resuscitator without manometer when compared with the manual resuscitator with manometer support (MS) group or automatic ventilator (AV) group. The study recommends for ventilatory support the use of a manual resuscitator equipped with MS or AVs, due to the risk of reduction in coronary perfusion pressure and iatrogenic thoracic injury during hyperventilation found using manual resuscitator without manometer. Lacerda RS , de Lima FCA , Bastos LP , Vinco AF , Schneider FBA , Coelho YL , Fernandes HGC , Bacalhau JMR , Bermudes IMS , da Silva CF , da Silva LP , Pezato R . Benefits of manometer in non-invasive ventilatory support. Prehosp Disaster Med. 2017;32(6):615-620.
Pharyngocutaneous fistula after total laryngectomy: Less common with mechanical stapler closure.
Calli, Caglar; Pinar, Ercan; Oncel, Semih
2011-05-01
The aim of the study was to compare the incidences of pharyngocutaneous fistula after total laryngectomy between patients who underwent manual and mechanical suturing for pharyngoesophageal closure. In a retrospective and prospective nonrandomized clinical study conducted at a single tertiary medical center between May 2002 and April 2009, we compared the incidence of pharyngocutaneous salivary fistula between two groups of patients after total laryngectomy. Sixty-one consecutive patients who underwent mechanical suturing with a 60-mm linear stapler (group A) were prospectively enrolled, and 121 patients who had undergone manual suturing (group B) were retrospectively reviewed. The groups were similar in terms of age, gender, comorbidities, TNM (tumor, node, metastasis) stage, and laryngeal tumor extension. The incidence of pharyngocutaneous salivary fistula was 4.9% in group A and 19.8% in group B (p = 0.014). Mechanical stapler closure of the pharynx after total laryngectomy was associated with a significant reduction in the incidence of pharyngocutaneous fistula compared with manual suture in selected cases.
Effects of mixing technique on bubble formation in alginate impression material.
McDaniel, Thomas F; Kramer, Robert T; Im, Francis; Snow, Dallin
2013-01-01
Previous studies have found that variations in mixing technique can influence the porosity content of alginate impression material. The aim of this study was twofold: determine whether bubble formation in alginate is influenced by the sequence of water/powder addition prior to mixing, and to compare 4 different mixing techniques. Manual spatulation, an automated spinning bowl, a centrifugal mixer and a vacuum mixer were evaluated for the resulting porosity in the set alginate. It was found that adding powder first, versus water first, made no difference in the bubble content using the 3 automated mixing techniques (P = 0.714). However, porosity was significantly less for powder-first trials using manual spatulation (P < 0.05). It was also found that surface porosity in the resulting impressions was significantly less for centrifugal and vacuum mixing when compared to manual spatulation, while internal porosity was significantly less for centrifugal mixing compared to all other mixing techniques (P < 0.05). The centrifugal mixing and vacuum mixing techniques required the least amount of mixing time.
NASA Technical Reports Server (NTRS)
Billman, Dorrit Owen; Schreckenghost, Debra; Miri, Pardis
2014-01-01
Astronauts will be responsible for executing a much larger body of procedures as human exploration moves further from Earth and Mission Control. Efficient, reliable methods for executing these procedures, including manual, automated, and mixed execution will be important. Our interface integrates step-by-step instruction with the means for execution. The research reported here compared manual execution using the new system to a system analogous to the manual-only system currently in use on the International Space Station, to assess whether user performance in manual operations would be as good or better with the new than with the legacy system. The system used also allows flexible automated execution. The system and our data lay the foundation for integrating automated execution into the flow of procedures designed for humans. In our formative study, we found speed and accuracy of manual procedure execution was better using the new, integrated interface over the legacy design.
Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer.
Lustberg, Tim; van Soest, Johan; Gooding, Mark; Peressutti, Devis; Aljabar, Paul; van der Stoep, Judith; van Elmpt, Wouter; Dekker, Andre
2018-02-01
Contouring of organs at risk (OARs) is an important but time consuming part of radiotherapy treatment planning. The aim of this study was to investigate whether using institutional created software-generated contouring will save time if used as a starting point for manual OAR contouring for lung cancer patients. Twenty CT scans of stage I-III NSCLC patients were used to compare user adjusted contours after an atlas-based and deep learning contour, against manual delineation. The lungs, esophagus, spinal cord, heart and mediastinum were contoured for this study. The time to perform the manual tasks was recorded. With a median time of 20 min for manual contouring, the total median time saved was 7.8 min when using atlas-based contouring and 10 min for deep learning contouring. Both atlas based and deep learning adjustment times were significantly lower than manual contouring time for all OARs except for the left lung and esophagus of the atlas based contouring. User adjustment of software generated contours is a viable strategy to reduce contouring time of OARs for lung radiotherapy while conforming to local clinical standards. In addition, deep learning contouring shows promising results compared to existing solutions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Dreizin, David; Bodanapally, Uttam K; Neerchal, Nagaraj; Tirada, Nikki; Patlas, Michael; Herskovits, Edward
2016-11-01
Manually segmented traumatic pelvic hematoma volumes are strongly predictive of active bleeding at conventional angiography, but the method is time intensive, limiting its clinical applicability. We compared volumetric analysis using semi-automated region growing segmentation to manual segmentation and diameter-based size estimates in patients with pelvic hematomas after blunt pelvic trauma. A 14-patient cohort was selected in an anonymous randomized fashion from a dataset of patients with pelvic binders at MDCT, collected retrospectively as part of a HIPAA-compliant IRB-approved study from January 2008 to December 2013. To evaluate intermethod differences, one reader (R1) performed three volume measurements using the manual technique and three volume measurements using the semi-automated technique. To evaluate interobserver differences for semi-automated segmentation, a second reader (R2) performed three semi-automated measurements. One-way analysis of variance was used to compare differences in mean volumes. Time effort was also compared. Correlation between the two methods as well as two shorthand appraisals (greatest diameter, and the ABC/2 method for estimating ellipsoid volumes) was assessed with Spearman's rho (r). Intraobserver variability was lower for semi-automated compared to manual segmentation, with standard deviations ranging between ±5-32 mL and ±17-84 mL, respectively (p = 0.0003). There was no significant difference in mean volumes between the two readers' semi-automated measurements (p = 0.83); however, means were lower for the semi-automated compared with the manual technique (manual: mean and SD 309.6 ± 139 mL; R1 semi-auto: 229.6 ± 88.2 mL, p = 0.004; R2 semi-auto: 243.79 ± 99.7 mL, p = 0.021). Despite differences in means, the correlation between the two methods was very strong and highly significant (r = 0.91, p < 0.001). Correlations with diameter-based methods were only moderate and nonsignificant. Mean semi-automated segmentation time effort was 2 min and 6 s and 2 min and 35 s for R1 and R2, respectively, vs. 22 min and 8 s for manual segmentation. Semi-automated pelvic hematoma volumes correlate strongly with manually segmented volumes. Since semi-automated segmentation can be performed reliably and efficiently, volumetric analysis of traumatic pelvic hematomas is potentially valuable at the point-of-care.
The effectiveness of manual therapy in treating cervicogenic dizziness: a systematic review.
Yaseen, Khalid; Hendrick, Paul; Ismail, Ayah; Felemban, Mohannad; Alshehri, Mansour Abdullah
2018-01-01
[Purpose] This review provides an evaluation of the evidence for the effectiveness of using manual therapy to treat cervicogenic dizziness. [Subjects and Methods] The literature was systematically searched on the May 2, 2016 using the following online databases: Medline, EMBASE, CINAHL and PEDro. This review included randomised controlled trials and compared the efficacy of manual therapy for the treatment of cervicogenic dizziness, compared to other types of intervention. This study measured changes based on dizziness intensity and frequency. [Results] The primary search found 30 articles, but only four articles met the inclusion criteria. Assessment of methodological quality was performed by two researchers using the PEDro scale. The level of evidence was determined using a recognised grading scale. Three out of the four articles were deemed to have high methodological quality, while the fourth was rated as moderate quality. The attributed level of evidence was moderate (level 2). [Conclusion] Manual therapy is potentially effective for managing cervicogenic dizziness. However, due to the heterogeneity of the results and techniques and the low number of studies, further research is recommended to provide conclusive evidence.
Ozcan, Ayse; Tulum, Zeliha; Pinar, Lamia; Başkurt, Ferdi
2004-12-01
This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymmetries in left-handed subjects.
Li, Zhen; He, Tao; Li, Chun; Sun, Lily; Chang, Jinlan; He, Yanyan; Zhao, Jizhi; Ji, Ning
2016-08-01
To compare the anti-gingivitis effect of a power toothbrush relative to a manual toothbrush control. This was a 3-month, randomized and controlled, single-center, parallel group, examiner-blinded clinical study. 123 Chinese adults in good general health and with at least 15 gingival bleeding sites, as measured by the Gingival Bleeding Index, were enrolled into the study. At baseline, pre-treatment gingivitis levels were assessed using the Mazza Bleeding Index. Subjects were then randomly assigned to receive either an oscillating-rotating power toothbrush [Oral-B Professional Care 7000 (D17u/EB17)] or a flat-trim manual toothbrush with tapered filaments (Lion Dentor Systema). Subjects brushed at home twice-daily with their assigned toothbrush and a marketed sodium fluoride dentifrice (Crest Cavity Protection dentifrice), and were reevaluated at Months 1, 2, and 3. 113 evaluable subjects completed the study. Both groups showed significant reductions in gingivitis from baseline for all time points measured (P< 0.001). At Months 1, 2 and 3, the power toothbrush demonstrated significantly greater gingivitis reductions of 7.11%, 9.20% and 8.47%, respectively, than the manual toothbrush (P< 0.01), and significantly fewer bleeding sites (17.3%, 23.9% and 24.3%, respectively, P< 0.05). No adverse events were reported or observed for either brush during the study. The power brush provided statistically significantly greater reductions in gingivitis compared with a manual toothbrush at Months 1, 2 and 3.
McKenzie, Kirsten; Walker, Sue; Tong, Shilu
It remains unclear whether the change from a manual to an automated coding system (ACS) for deaths has significantly affected the consistency of Australian mortality data. The underlying causes of 34,000 deaths registered in 1997 in Australia were dual coded, in ICD-9 manually, and by using an automated computer coding program. The diseases most affected by the change from manual to ACS were senile/presenile dementia, and pneumonia. The most common disease to which a manually assigned underlying cause of senile dementia was coded with ACS was unspecified psychoses (37.2%). Only 12.5% of codes assigned by ACS as senile dementia were coded the same by manual coders. This study indicates some important differences in mortality rates when comparing mortality data that have been coded manually with those coded using an automated computer coding program. These differences may be related to both the different interpretation of ICD coding rules between manual and automated coding, and different co-morbidities or co-existing conditions among demographic groups.
Ramme, Austin J; Voss, Kevin; Lesporis, Jurinus; Lendhey, Matin S; Coughlin, Thomas R; Strauss, Eric J; Kennedy, Oran D
2017-05-01
MicroCT imaging allows for noninvasive microstructural evaluation of mineralized bone tissue, and is essential in studies of small animal models of bone and joint diseases. Automatic segmentation and evaluation of articular surfaces is challenging. Here, we present a novel method to create knee joint surface models, for the evaluation of PTOA-related joint changes in the rat using an atlas-based diffeomorphic registration to automatically isolate bone from surrounding tissues. As validation, two independent raters manually segment datasets and the resulting segmentations were compared to our novel automatic segmentation process. Data were evaluated using label map volumes, overlap metrics, Euclidean distance mapping, and a time trial. Intraclass correlation coefficients were calculated to compare methods, and were greater than 0.90. Total overlap, union overlap, and mean overlap were calculated to compare the automatic and manual methods and ranged from 0.85 to 0.99. A Euclidean distance comparison was also performed and showed no measurable difference between manual and automatic segmentations. Furthermore, our new method was 18 times faster than manual segmentation. Overall, this study describes a reliable, accurate, and automatic segmentation method for mineralized knee structures from microCT images, and will allow for efficient assessment of bony changes in small animal models of PTOA.
Fernández, Sarah N.; González, Rafael; Solana, María J.; Urbano, Javier; Toledo, Blanca
2017-01-01
Aims Chest compressions (CC) during cardiopulmonary resuscitation are not sufficiently effective in many circumstances. Mechanical CC could be more effective than manual CC, but there are no studies comparing both techniques in children. The objective of this study was to compare the effectiveness of manual and mechanical chest compressions with Thumper device in a pediatric cardiac arrest animal model. Material and methods An experimental model of asphyxial cardiac arrest (CA) in 50 piglets (mean weight 9.6 kg) was used. Animals were randomized to receive either manual CC or mechanical CC using a pediatric piston chest compressions device (Life-Stat®, Michigan Instruments). Mean arterial pressure (MAP), arterial blood gases and end-tidal CO2 (etCO2) values were measured at 3, 9, 18 and 24 minutes after the beginning of resuscitation. Results There were no significant differences in MAP, DAP, arterial blood gases and etCO2 between chest compression techniques during CPR. Survival rate was higher in the manual CC (15 of 30 = 50%) than in the mechanical CC group (3 of 20 = 15%) p = 0.016. In the mechanical CC group there was a non significant higher incidence of haemorrhage through the endotracheal tube (45% vs 20%, p = 0.114). Conclusions In a pediatric animal model of cardiac arrest, mechanical piston chest compressions produced lower survival rates than manual chest compressions, without any differences in hemodynamic and respiratory parameters. PMID:29190801
van der Krieke, Lian; Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith Gm; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-08-07
Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher's tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use.
Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith GM; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-01-01
Background Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. Objective This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. Methods We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher’s tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). Results An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Conclusions Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use. PMID:26254160
Update on mechanical cardiopulmonary resuscitation devices.
Rubertsson, Sten
2016-06-01
The aim of this review is to update and discuss the use of mechanical chest compression devices in treatment of cardiac arrest. Three recently published large multicenter randomized trials have not been able to show any improved outcome in adult out-of-hospital cardiac arrest patients when compared with manual chest compressions. Mechanical chest compression devices have been developed to better deliver uninterrupted chest compressions of good quality. Prospective large randomized studies have not been able to prove a better outcome compared to manual chest compressions; however, latest guidelines support their use when high-quality manual chest compressions cannot be delivered. Mechanical chest compressions can also be preferred during transportation, in the cath-lab and as a bridge to more invasive support like extracorporeal membrane oxygenation.
Ti, Lian Kah; Ang, Sophia Bee Leng; Saw, Sharon; Sethi, Sunil Kumar; Yip, James W L
2012-08-01
Timely reporting and acknowledgement are crucial steps in critical laboratory results (CLR) management. The authors previously showed that an automated pathway incorporating short messaging system (SMS) texts, auto-escalation, and manual telephone back-up improved the rate and speed of physician acknowledgement compared with manual telephone calling alone. This study investigated if it also improved the rate and speed of physician intervention to CLR and whether utilising the manual back-up affected intervention rates. Data from seven audits between November 2007 and January 2011 were analysed. These audits were carried out to assess the robustness of CLR reporting process in the authors' institution. Comparisons were made in the rate and speed of acknowledgement and intervention between the audits performed before and after automation. Using the automation audits, the authors compared intervention data between communication with SMS only and when manual intervention was required. 1680 CLR were reported during the audit periods. Automation improved the rate (100% vs 84.2%; p<0.001) and speed (median 12 min vs 23 min; p<0.001) of CLR acknowledgement. It also improved the rate (93.7% vs 84.0%, p<0.001) and speed (median 21 min vs 109 min; p<0.001) of CLR intervention. From the automation audits, the use of SMS only did not improve physician intervention rates. The automated communication pathway improved physician intervention rate and time in tandem with improved acknowledgement rate and time when compared with manual telephone calling. The use of manual intervention to augment automation did not adversely affect physician intervention rate, implying that an end-to-end pathway was more important than automation alone.
Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M
2017-05-01
To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.
Bailey, Lane B; Thigpen, Charles A; Hawkins, Richard J; Beattie, Paul F; Shanley, Ellen
Baseball players displaying deficits in shoulder range of motion (ROM) are at increased risk of arm injury. Currently, there is a lack of consensus regarding the best available treatment options to restore shoulder ROM. Instrumented manual therapy with self-stretching will result in clinically significant deficit reductions when compared with self-stretching alone. Controlled laboratory study. Shoulder ROM and humeral torsion were assessed in 60 active baseball players (mean age, 19 ± 2 years) with ROM deficits (nondominant - dominant, ≥15°). Athletes were randomly assigned to receive a single treatment of instrumented manual therapy plus self-stretching (n = 30) or self-stretching only (n = 30). Deficits in internal rotation, horizontal adduction, and total arc of motion were compared between groups immediately before and after a single treatment session. Treatment effectiveness was determined by mean comparison data, and a number-needed-to-treat (NNT) analysis was used for assessing the presence of ROM risk factors. Prior to intervention, players displayed significant ( P < 0.001) dominant-sided deficits in internal rotation (-26°), total arc of motion (-18°), and horizontal adduction (-17°). After the intervention, both groups displayed significant improvements in ROM, with the instrumented manual therapy plus self-stretching group displaying greater increases in internal rotation (+5°, P = 0.010), total arc of motion (+6°, P = 0.010), and horizontal adduction (+7°, P = 0.004) compared with self-stretching alone. For horizontal adduction deficits, the added use of instrumented manual therapy with self-stretching decreased the NNT to 2.2 (95% CI, 2.1-2.4; P = 0.010). Instrumented manual therapy with self-stretching significantly reduces ROM risk factors in baseball players with motion deficits when compared with stretching alone. The added benefits of manual therapy may help to reduce ROM deficits in clinical scenarios where stretching alone is ineffective.
Improved sampling and analysis of images in corneal confocal microscopy.
Schaldemose, E L; Fontain, F I; Karlsson, P; Nyengaard, J R
2017-10-01
Corneal confocal microscopy (CCM) is a noninvasive clinical method to analyse and quantify corneal nerve fibres in vivo. Although the CCM technique is in constant progress, there are methodological limitations in terms of sampling of images and objectivity of the nerve quantification. The aim of this study was to present a randomized sampling method of the CCM images and to develop an adjusted area-dependent image analysis. Furthermore, a manual nerve fibre analysis method was compared to a fully automated method. 23 idiopathic small-fibre neuropathy patients were investigated using CCM. Corneal nerve fibre length density (CNFL) and corneal nerve fibre branch density (CNBD) were determined in both a manual and automatic manner. Differences in CNFL and CNBD between (1) the randomized and the most common sampling method, (2) the adjusted and the unadjusted area and (3) the manual and automated quantification method were investigated. The CNFL values were significantly lower when using the randomized sampling method compared to the most common method (p = 0.01). There was not a statistical significant difference in the CNBD values between the randomized and the most common sampling method (p = 0.85). CNFL and CNBD values were increased when using the adjusted area compared to the standard area. Additionally, the study found a significant increase in the CNFL and CNBD values when using the manual method compared to the automatic method (p ≤ 0.001). The study demonstrated a significant difference in the CNFL values between the randomized and common sampling method indicating the importance of clear guidelines for the image sampling. The increase in CNFL and CNBD values when using the adjusted cornea area is not surprising. The observed increases in both CNFL and CNBD values when using the manual method of nerve quantification compared to the automatic method are consistent with earlier findings. This study underlines the importance of improving the analysis of the CCM images in order to obtain more objective corneal nerve fibre measurements. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics
RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.
2015-01-01
BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665
Sharma, Ruchi; Trehan, Mridula; Sharma, Sunil; Jharwal, Vikas; Rathore, Nidhi
2015-01-01
Maintenance of good oral hygiene is important for patients undergoing fixed orthodontic treatment. The aim of this study was to evaluate the effectiveness of a manual orthodontic toothbrush, powered toothbrush with oscillating head and sonic toothbrush in controlling plaque, gingivitis and interdental bleeding in patients undergoing fixed orthodontic treatment, and to compare their relative efficacy. Sixty subjects, who were to receive orthodontic treatment with both upper and lower fixed appliances, were randomly divided into three study groups, with 20 patients in each group. Groups I to III were given manual orthodontic, powered and sonic toothbrushes, respectively. Plaque index (PI), gingival index (GI) and interdental bleeding index were scored to assess the level of plaque accumulation, gingival health and interdental bleeding at baseline; 4 and 8 weeks recall visits after fixed appliance bonding. Paired t-tests and one-way analysis of variance (ANOVA) tests were used for intragroup and intergroup comparisons. The level of statistical significance was set at p < 0.05. This study showed that a significant reduction in all the three indices scores was found from baseline to 4 and 8 weeks in group III. On intergroup comparison, no statistically significant differences were detected between the three groups for any of the parameters assessed. On intragroup comparison, sonic brushes performed superiorly in reducing gingivitis, plaque and interdental bleeding as compared to the manual orthodontic and powered brushes. On intergroup comparison, the relative comparative effectiveness was found to be similar for all the three brushes. How to cite this article: Sharma R, Trehan M, Sharma S, Jharwal V, Rathore N. Comparison of Effectiveness of Manual Orthodontic, Powered and Sonic Toothbrushes on Oral Hygiene of Fixed Orthodontic Patients. Int J Clin Pediatr Dent 2015;8(3):181-189.
Manual therapy is an effective treatment for frozen shoulder in diabetics: an observational study.
Düzgün, Irem; Baltaci, Gül; Atay, Ozgür Ahmet
2012-01-01
This study aims to compare the efficacy of manual therapy in the frozen shoulder patients with or without diabetes mellitus. Between May 2006 and January 2008, 50 patients (10 males, 40 females; mean age 52 ± 10 years; range 40 to 65 years) orthopedic surgeons referred to the Sports Physiotherapy Unit were included in the study. The patients were divided into two groups, including patients with primary frozen shoulder with type II diabetes mellitus (n=12) and non diabetics (n=38). All patients underwent a rehabilitation program including cold application, manual therapy and exercises twice a week. A total of 16 treatment sessions were performed. The most important part of the manual therapy included scapular mobilization and posterior capsule stretching. The range of motion was measured by goniometry. Functional activity status was assessed by Constant's score. The pain level was evaluated by visual analog scale, while muscle strength was evaluated by hand-held dynamometer. Student t-test was used to compare between the parameters of groups, while Paired sample t-test was used to compare pre- and post-treatment parameters of the patients. The range of motion, functional activity status and muscular strength were improved and the pain level was reduced after rehabilitation in all of the patients in both groups (p<0.05). There was no difference in duration of the treatment between the groups (p>0.05). There were no differences in range of motion, functional activity status, pain level, and muscle strength before and after rehabilitation between the groups (p>0.05). Manual therapy approaches may be safely applied in diabetic patients with frozen shoulder.
Petroglou, Dimitrios; Didagelos, Matthaios; Chalikias, Georgios; Tziakas, Dimitrios; Tsigkas, Grigorios; Hahalis, Georgios; Koutouzis, Michael; Ntatsios, Antonios; Tsiafoutis, Ioannis; Hamilos, Michael; Kouparanis, Antonios; Konstantinidis, Nikolaos; Sofidis, Georgios; Pancholy, Samir B; Karvounis, Haralambos; Bertrand, Olivier Francois; Ziakas, Antonios
2018-06-11
The aim of this study was to compare manual versus mechanical compression of the radial artery after coronary angiography via transradial access regarding radial artery occlusion (RAO), access-site bleeding complications, and duration of hemostasis. Hemostasis of the radial artery after sheath removal can be achieved either by manual compression at the puncture site or by using a mechanical hemostasis device. Because mechanical compression exerts a more stable, continuous pressure on the artery, it could be hypothesized that it is more effective compared with manual compression regarding hemostasis time, bleeding, and RAO risks. A total of 589 patients undergoing diagnostic coronary angiography by transradial access with a 5-F sheath were randomized in a 1:1 ratio to receive either manual or mechanical patent hemostasis of the radial artery. Radial artery patency was evaluated by color duplex ultrasonography 24 h after the procedure. The primary endpoint was early RAO at 24 h. Secondary endpoints included access-site bleeding complications and duration of hemostasis. Thirty-six (12%) early RAOs occurred in the manual group, and 24 (8%) occurred in the mechanical group (p = 0.176). There were no significant differences between the 2 groups regarding access-site bleeding complications (hematoma, 52 [17%] vs. 50 [18%]; p = 0.749; bleedings, 8 [3%] vs. 9 [3%]; p = 1.000). Duration of hemostasis was significantly shorter in the manual group (22 ± 34 min vs. 119 ± 72 min with mechanical compression; p < 0.001). Manual and mechanical compression resulted in similar rates of early RAO, although the total duration of hemostasis was significantly shorter in the manual group. Copyright © 2018 American College of Cardiology Foundation. All rights reserved.
Landes, Constantin A; Weichert, Frank; Geis, Philipp; Helga, Fritsch; Wagner, Mathias
2006-03-01
Cleft lip and palate reconstructive surgery requires thorough knowledge of normal and pathological labial, palatal, and velopharyngeal anatomy. This study compared two software algorithms and their 3D virtual anatomical reconstruction because exact 3D micromorphological reconstruction may improve learning, reveal spatial relationships, and provide data for mathematical modeling. Transverse and frontal serial sections of the midface of 18 fetal specimens (11th to 32nd gestational week) were used for two manual segmentation approaches. The first manual segmentation approach used bitmap images and either Windows-based or Mac-based SURFdriver commercial software that allowed manual contour matching, surface generation with average slice thickness, 3D triangulation, and real-time interactive virtual 3D reconstruction viewing. The second manual segmentation approach used tagged image format and platform-independent prototypical SeViSe software developed by one of the authors (F.W.). Distended or compressed structures were dynamically transformed. Registration was automatic but allowed manual correction, such as individual section thickness, surface generation, and interactive virtual 3D real-time viewing. SURFdriver permitted intuitive segmentation, easy manual offset correction, and the reconstruction showed complex spatial relationships in real time. However, frequent software crashes and erroneous landmarks appearing "out of the blue," requiring manual correction, were tedious. Individual section thickness, defined smoothing, and unlimited structure number could not be integrated. The reconstruction remained underdimensioned and not sufficiently accurate for this study's reconstruction problem. SeViSe permitted unlimited structure number, late addition of extra sections, and quantified smoothing and individual slice thickness; however, SeViSe required more elaborate work-up compared to SURFdriver, yet detailed and exact 3D reconstructions were created.
ERIC Educational Resources Information Center
Hatlenes, Linda Teikari; Eikeseth, Svein
2016-01-01
Employing a randomized control group design, this study compared the efficacy of staff training using theory training, hands-on supervision and a self-instructional teaching manual. Participants were 12 undergraduate, health or social-work students. Initially, participants were given a three-hour lecture, and as a result, staff-participants…
Divergent Development of Manual Skills in Children Who Are Blind or Sighted
ERIC Educational Resources Information Center
Brambring, Michael
2007-01-01
This empirical study compared the average ages at which four children with congenital blindness acquired 32 fine motor skills with age norms for sighted children. The results indicated that the children experienced extreme developmental delays in the acquisition of manual skills and a high degree of variability in developmental delays within and…
Manualized Family-Based Treatment for Anorexia Nervosa: A Case Series.
ERIC Educational Resources Information Center
Le Grange, Daniel; Binford, Roslyn; Loeb, Katharine L.
2005-01-01
Objective: The purpose of this study was to describe a case series of children and adolescents (mean age = 14.5 years, SD = 2.3; range 9-18) with anorexia nervosa who received manualized family-based treatment for their eating disorder. Method: Forty-five patients with anorexia nervosa were compared pre- and post-treatment on weight and menstrual…
ERIC Educational Resources Information Center
Hsu, Chien-Ju; Thompson, Cynthia K.
2018-01-01
Purpose: The purpose of this study is to compare the outcomes of the manually coded Northwestern Narrative Language Analysis (NNLA) system, which was developed for characterizing agrammatic production patterns, and the automated Computerized Language Analysis (CLAN) system, which has recently been adopted to analyze speech samples of individuals…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoang Duc, Albert K., E-mail: albert.hoangduc.ucl@gmail.com; McClelland, Jamie; Modat, Marc
Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) wasmore » then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary.« less
Malcolme-Lawes, Louisa C; Lim, Phang Boon; Koa-Wing, Michael; Whinnett, Zachary I; Jamil-Copley, Shahnaz; Hayat, Sajad; Francis, Darrel P; Kojodjojo, Pipin; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa
2013-01-01
Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System
Punjabi, Naresh M.; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N.
2015-01-01
Study Objectives: Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. Design: The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Setting: Clinical sleep laboratories. Measurements and Results: A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90–0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91–0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Conclusion: Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated scoring platforms provide a viable complement of tools in the diagnostic armamentarium of sleep medicine. Citation: Punjabi NM, Shifa N, Dorffner G, Patil S, Pien G, Aurora RN. Computer-assisted automated scoring of polysomnograms using the Somnolyzer system. SLEEP 2015;38(10):1555–1566. PMID:25902809
Validation of motion correction techniques for liver CT perfusion studies
Chandler, A; Wei, W; Anderson, E F; Herron, D H; Ye, Z; Ng, C S
2012-01-01
Objectives Motion in images potentially compromises the evaluation of temporally acquired CT perfusion (CTp) data; image registration should mitigate this, but first requires validation. Our objective was to compare the relative performance of manual, rigid and non-rigid registration techniques to correct anatomical misalignment in acquired liver CTp data sets. Methods 17 data sets in patients with liver tumours who had undergone a CTp protocol were evaluated. Each data set consisted of a cine acquisition during a breath-hold (Phase 1), followed by six further sets of cine scans (each containing 11 images) acquired during free breathing (Phase 2). Phase 2 images were registered to a reference image from Phase 1 cine using two semi-automated intensity-based registration techniques (rigid and non-rigid) and a manual technique (the only option available in the relevant vendor CTp software). The performance of each technique to align liver anatomy was assessed by four observers, independently and blindly, on two separate occasions, using a semi-quantitative visual validation study (employing a six-point score). The registration techniques were statistically compared using an ordinal probit regression model. Results 306 registrations (2448 observer scores) were evaluated. The three registration techniques were significantly different from each other (p=0.03). On pairwise comparison, the semi-automated techniques were significantly superior to the manual technique, with non-rigid significantly superior to rigid (p<0.0001), which in turn was significantly superior to manual registration (p=0.04). Conclusion Semi-automated registration techniques achieved superior alignment of liver anatomy compared with the manual technique. We hope this will translate into more reliable CTp analyses. PMID:22374283
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.
Punjabi, Naresh M; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N
2015-10-01
Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Clinical sleep laboratories. A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90-0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91-0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated scoring platforms provide a viable complement of tools in the diagnostic armamentarium of sleep medicine. © 2015 Associated Professional Sleep Societies, LLC.
Musculoskeletal pain, depression, and stress among Latino manual laborers in North Carolina.
Tribble, Anna Grace; Summers, Phillip; Chen, Haiying; Quandt, Sara A; Arcury, Thomas A
2016-11-01
The jobs of Latino manual laborers place their mental and physical health at risk. This study evaluates the associations among musculoskeletal pain, mental health, and work organization in Latino manual laborers. Farmworkers and nonfarmworkers (n = 189) in North Carolina were interviewed for self-reported musculoskeletal pain, depressive symptoms, stress, work safety climate, and precarious job status. More nonfarmworkers than farmworkers had neck and shoulder pain, but they did not differ in other areas of musculoskeletal pain. Depressive symptoms had a significant association with neck and shoulder pain (p < .05). Precariousness had a significant association with back pain (p < .05). Farmworker participants had H-2A visas and were afforded some protection compared to nonfarmworker manual workers. Research is needed to improve policy that relieves pain and improves mental health for all Latino manual workers.
Performance of Copan WASP for Routine Urine Microbiology
Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.
2015-01-01
This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255
Treatment manuals, training and successful provision of stop smoking behavioural support.
Brose, Leonie S; McEwen, Andy; Michie, Susan; West, Robert; Chew, Xie Yin; Lorencatto, Fabiana
2015-08-01
Translating evidence-based behaviour change interventions into practice is aided by use of treatment manuals specifying the recommended content and format of interventions, and evidence-based training. This study examined whether outcomes of stop smoking behavioural support differed with practitioner's use and evaluation of treatment manuals, or practitioner's training. English stop smoking practitioners were invited to complete an online survey including questions on: practitioners' training, availability, use and perceived utility of manuals, and annual biochemically-validated success rates of quit attempts supported (practitioner-reported). Mean success rates were compared between practitioners with/without access to manuals, those using/not using manuals, perceived utility ratings of manuals, and consecutive levels of training completed. Success rates were higher if practitioners had a manual (Mean (SD) = 54.0 (24.0) versus 48.0 (25.3), t(838) = 2.48, p = 0.013; n = 840), used a manual (F(2,8237) = 4.78, p = 0.009, n = 840), perceived manuals as more useful (F(3,834) = 2.90, p = 0.034, n = 840), and had completed training (F(3,709) = 4.81, p = 0.002, n = 713). Differences were diminished when adjusting for professional and demographic characteristics and no longer reached statistical significance using a conventional alpha for perceived utility of manuals and training status (both p = 0.1). Practitioners' performance in supporting smokers to quit varied with availability and use of treatment manuals. Evidence was weaker for perceived utility of manuals and practitioners' evidence-based training. Ensuring practitioners have access to treatment manuals within their service, promoting manual use, and training practitioners to competently apply manuals is likely to contribute to higher success rates in clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
The AASM scoring manual: a critical appraisal.
Grigg-Damberger, Madeleine M
2009-11-01
Summarize recently published studies and critiques evaluating the effects of the American Academy of Sleep Medicine (AASM) Sleep Scoring Manual. Only a few retrospective studies have been published evaluating the new AASM Scoring Manual. These have shown that when scoring polysomnograms (PSGs) using the AASM rules compared to previous standards and guidelines: increased amount and percentage of sleep time in Non-Rapid Eye Movement Sleep (NREM) 1 (N1) and N3 sleep, and decreased NREM 2 (N2) sleep; improved interscorer reliability when scoring sleep stages in adults; large differences in apnea-hypopnea indexes (AHIs) using different hypopnea scoring definitions; and PSGs scored using the 'recommended' hypopnea definition in the new manual identified no significant sleep disordered breathing in 40% of lean individuals with symptomatic OSA (AHI ≥5/h by 1999 'Chicago' criteria) and a favorable response to treatment. Two years have passed since the AASM Scoring Manual was published, garnering less criticism than was feared by those who developed it. The improvement in interscorer reliability using the Manual is heartening since this goal shaped many of the choices made. The alternative hypopnea rule should be endorsed as a recommended option. The AASM Scoring Manual provides a foundation upon which we all can build rules and methods that quantify the complexity of sleep and its disorders. Multicenter validation and refinement of the Manual is encouraged.
One year follow-up of the Chicago televised smoking cessation program.
Flay, B R; Gruder, C L; Warnecke, R B; Jason, L A; Peterson, P
1989-01-01
We compared the relative effectiveness of four different conditions of self-help and social support provided to people attempting to quit smoking in conjunction with a televised cessation program: Smokers ready to quit were able to request written manuals from hardware stores to accompany a televised program. At worksites we provided the written manual to all workers. At a random half of the worksites, we also provided training to discussion leaders who subsequently led discussions among smokers attempting to quit with the program. At health maintenance organization sites we invited smokers who had requested program materials to participate in similar group discussions at health centers. In this paper we report one year follow-up results for the above four groups and compare them with previously reported results of a self-help manual alone. Results for the television plus manual condition were better than those of past studies (25 percent nonsmoking prevalence and 10 percent continuous cessation one year after the program) and considerably better than the manual alone. None of the other conditions designed to supplement the manual plus television produced better long-term outcomes; we explore the reasons for this. The program did encourage and help over 50,000 Chicago smokers to attempt quitting with the American Lung Association manual, 100 times as many as would have done so without the televised program. At least 15 other similar programs implemented since 1984 multiply this effect. PMID:2782506
Li, Xiadong; Wang, Lu; Wang, Jiahao; Han, Xu; Xia, Bing; Wu, Shixiu; Hu, Weigang
2017-01-01
This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p < 0.05). Meanwhile, auto-planning further reduced the maximum dose (D max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V 5 ) for the lung (p = 0.005). For auto-planning, the V 5 of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V 5 of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Zakkar, Mustafa; Kanagasabay, Robin; Hunt, Ian
2014-04-01
A best evidence topic in cardiothoracic surgery was written according to a structured protocol. The question addressed was whether manual closure of the bronchial stump is safer with lower failure rates than mechanical closure using a stapling device following anatomical lung resection. One hundred and twenty-nine papers were identified using the search below. Eight papers presented the best evidence to answer the clinical question as they included sufficient number of patients to reach conclusions regarding the issues of interest for this review. Complications, complication rates and operation time were included in the assessment. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. When looking at manual vs mechanical staples, it was noted that stapler failure can occur in around 4% of cases. The rate of bronchopleural fistula (BPF) development varied more in patients who underwent manual closure (1.5-12.5%) than in patients who underwent mechanical closure (1-5.7%). Although most of the studies reviewed showed no statistical differences between manual and mechanical closure in terms of BPF development, one study, however, showed that manual closure was significantly associated with lower numbers of postoperative BPF, while another study showed that mechanical closure is significantly associated with lower incidence of BPF. When looking at the role of the learning curve and training opportunities, it seems that the surgeon's inexperience when using mechanical staples can contribute to BPF development. A surgeon's experience can play a major role in the prevention of BPF development in patients having manual closure. Manual closure can provide a cheap and reliable technique when compared with costs incurred from using staplers, it is applicable in all situations and can be taught to surgeons in training with an acceptable risk. However, there is a lack of evidence to suggest that manual closure is better than mechanical stapler closure following anatomical lung resection.
Carminati, M Chiara; Boniotti, Cinzia; Fusini, Laura; Andreini, Daniele; Pontone, Gianluca; Pepi, Mauro; Caiani, Enrico G
2016-05-01
The aim of this study was to compare the performance of quantitative methods, either semiautomated or automated, for left ventricular (LV) nonviable tissue analysis from cardiac magnetic resonance late gadolinium enhancement (CMR-LGE) images. The investigated segmentation techniques were: (i) n-standard deviations thresholding; (ii) full width at half maximum thresholding; (iii) Gaussian mixture model classification; and (iv) fuzzy c-means clustering. These algorithms were applied either in each short axis slice (single-slice approach) or globally considering the entire short-axis stack covering the LV (global approach). CMR-LGE images from 20 patients with ischemic cardiomyopathy were retrospectively selected, and results from each technique were assessed against manual tracing. All methods provided comparable performance in terms of accuracy in scar detection, computation of local transmurality, and high correlation in scar mass compared with the manual technique. In general, no significant difference between single-slice and global approach was noted. The reproducibility of manual and investigated techniques was confirmed in all cases with slightly lower results for the nSD approach. Automated techniques resulted in accurate and reproducible evaluation of LV scars from CMR-LGE in ischemic patients with performance similar to the manual technique. Their application could minimize user interaction and computational time, even when compared with semiautomated approaches.
Lee, Dong-Yeop; Han, Ji-Su; Jang, Eun-Ji; Seo, Dong-Kwon; Hong, Ji-Heon; Lee, Sang-Sook; Lee, Dong-Geol; Yu Lee, Jae-Ho
2014-01-01
One of the major symptoms when women are wearing high heels for a long time is leg swelling. The purpose of this study was to compare the effect of manual lymph drainage with ultrasound therapy. The forty-five healthy women of twenties were participated in this study and divided randomly into three groups; manual lymph drainage group (n=15), ultrasound therapy group (n=15) and control group (n=15). Swelling was measured before wearing the high heels (10 cm-height), after one-hour of wearing the high heels, wearing the high heels of one-hour after the intervention of 15 minutes. Also swelling was calculated by using a tape measure, volumeter and body composition analyzer. Statistical analysis of the comparison between the three groups was performed by one-way ANOVA. Also comparison to the mean value in swelling according to the time was performed by repeated measure ANOVA. As the result of this study, a significant changes have emerged within each of manual lymph drainage, ultrasound therapy and control group (p< 0.05). However, there were no significant differences between each group (p> 0.05). But the mean value of manual lymph drainage group showed the tendency of fast recovering before causing swelling. Therefore, we consider that the clinical treatment of manual lymph drainage and ongoing studies will be made since manual lymph drainage is very effective in releasing the leg swelling caused by wearing high heels and standing for a long time at work.
Dodd, Tamsin E L; Deakin, Charles D; Petley, Graham W; Clewlow, Frank
2004-12-01
Firm paddle force during defibrillation lowers transthoracic impedance (TTI) and increases transmyocardial current, increasing the chances of successful cardioversion. Current protocols recommend that if defibrillation using the anterior-apical (AA) paddle position fails, the anterior-posterior (AP) position should be used. This generally requires the patient to be placed in the left lateral position with the operator leaning over the patient. Avoiding physical contact with the patient during defibrillation subjectively makes application of firm paddle force difficult in the AP position. We compared TTI between the AA and AP positions and between manual paddles and self-adhesive pads to establish if the AP position precludes firm paddle force and to compare TTI between paddles and self-adhesive pads. Twenty-one consecutive patients undergoing elective cardioversion (age 39-82) were studied. TTI was measured between pairs of manually held paddles and self-adhesive pads using AA placement with the patient supine, and AP placement with the patient left lateral position. Mean TTI using the AP electrode position was lower using manual paddles (66.5 Omega; 95% CI 60.2-72.9 Omega) than that using self-adhesive pads (92.1 Omega; 95% CI 81.5-102.7 Omega; 95% CI between the mean =15.8-35.5 Omega; P <0.0001). TTI was significantly less using the manual paddles compared with self-adhesive pads in both AA and AP positions (P <0.0001). Despite the subjective difficulties of defibrillating patients in the AP position whilst leaning over them, use of manual paddles achieves a lower TTI than that achieved with self-adhesive pads.
Copple, Susan S.; Jaskowski, Troy D.; Giles, Rashelle; Hill, Harry R.
2014-01-01
Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratories for ANA HEp-2 IIF testing were included. Samples were read using the archived images on NOVA View and compared to results obtained from manual reading. Results. At a 1 : 40/1 : 80 dilution the resulting comparison demonstrated 94.8%/92.9% positive, 97.4%/97.4% negative, and 96.5%/96.2% total agreements between manual IIF and NOVA View archived images. Agreement of identifiable patterns between methods was 97%, with PCNA and mixed patterns undetermined. Conclusion. Excellent agreements were obtained between reading archived images on NOVA View and manually on a fluorescent microscope. In addition, workflow benefits were observed which need to be analyzed in future studies. PMID:24741573
Umbilical vein injection for management of retained placenta.
Nardin, Juan Manuel; Weeks, Andrew; Carroli, Guillermo
2011-05-11
If a retained placenta is left untreated, there is a high risk of maternal death. However, manual removal of the placenta is an invasive procedure with serious complications of haemorrhage, infection or genital tract trauma. To assess the use of umbilical vein injection (UVI) of saline solution alone or with oxytocin in comparison either with expectant management or with an alternative solution or other uterotonic agent for retained placenta. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (28 February 2011). Randomized trials comparing UVI of saline or other fluids, with or without oxytocics, either with expectant management or with an alternative solution or other uterotonic agent, in the management of retained placenta. Two review authors assessed the methodological quality of the studies and extracted the data. We included 15 trials (1704 women). The trials were of variable quality. Compared with expectant management, UVI of saline solution alone did not show any significant difference in the incidence of manual removal of the placenta (risk ratio (RR) 0.99; 95% confidence interval (CI) 0.84 to 1.16). UVI of oxytocin solution compared with expectant management showed no reduction in the need for manual removal (RR 0.87; 95% CI 0.74 to 1.03).Oxytocin solution compared with saline solution alone showed a reduction in manual removal of the placenta, but this was not statistically significant (RR 0.91; 95% CI 0.82 to 1.00). When only high-quality studies were assessed, there was no statistical difference (RR 0.92; 95% CI 0.83 to 1.01). We detected no differences in any of the other outcomes.UVI of oxytocin solution compared with UVI of plasma expander showed no statistically significant difference in the outcomes assessed by the only one small trial included. Prostaglandin solution compared with saline solution alone was associated with a statistically significant lower incidence in manual removal of placenta (RR 0.42; 95% CI 0.22 to 0.82) but we observed no difference in the other outcomes evaluated. Prostaglandin plus saline solution showed a statistically significant reduction in manual removal of placenta when compared with oxytocin plus saline solution (RR 0.43; 95% CI 0.25 to 0.75), and we also observed a small reduction in time from injection to placental delivery (mean difference -6.00; 95% CI -8.78 to -3.22). However, there were only two small trials contributing to this meta-analysis. UVI of oxytocin solution is an inexpensive and simple intervention that could be performed while placental delivery is awaited. However, high-quality randomized trials show that the use of oxytocin has little or no effect. Further research into the optimal timing of manual removal and into UVI of prostaglandins or plasma expander is warranted.
Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K.
2017-01-01
Objective To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Design Prospective and retrospective observational study. Setting Delivery suite in a tertiary referral teaching hospital in England. Population A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006–2013. Methods Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Main outcome measures Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Results Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Conclusions Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth. PMID:28489924
Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K
2017-01-01
To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Prospective and retrospective observational study. Delivery suite in a tertiary referral teaching hospital in England. A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013. Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.
Abu Taleb, Walaa; Rehan Youssef, Aliaa; Saleh, Amir
2016-10-01
Manual pressure release (MPR) is a popular treatment of trigger points. Yet, treatment response may be influenced by inconsistent application of pressure. Further, it may contribute to increased risk of work-related musculoskeletal disorders of the wrist and hand in therapists. Therefore, this study aimed at introducing a novel method to apply pressure using the algometer and to compare its effectiveness to MPR. Forty-five volunteers with active trigger points of the upper trapezius received algometer pressure release (APR), MPR, or sham ultrasound (US). Pain pressure threshold (PPT) and contralateral active and passive neck side-bending ranges were assessed at baseline and immediately after a single session. Results showed no significant differences in post-treatment PPT between the study groups (p > 0.05). The APR group showed a significant increase in passive side-bending range compared with the two other groups, whereas active range improved in the APR compared with the US group (p < 0.05). Our results show that using algometer to apply pressure release to upper trapezius trigger points is more effective compared with manual release and sham US. Copyright © 2016 Elsevier Ltd. All rights reserved.
Neubert, Ales; Fripp, Jurgen; Engstrom, Craig; Gal, Yaniv; Crozier, Stuart; Kingsley, Michael I C
2014-11-01
Magnetic resonance (MR) examinations of morphologic characteristics of intervertebral discs (IVDs) have been used extensively for biomechanical studies and clinical investigations of the lumbar spine. Traditionally, the morphologic measurements have been performed using time- and expertise-intensive manual segmentation techniques not well suited for analyses of large-scale studies.. The purpose of this study is to introduce and validate a semiautomated method for measuring IVD height and mean sagittal area (and volume) from MR images to determine if it can replace the manual assessment and enable analyses of large MR cohorts. This study compares semiautomated and manual measurements and assesses their reliability and agreement using data from repeated MR examinations. Seven healthy asymptomatic males underwent 1.5-T MR examinations of the lumbar spine involving sagittal T2-weighted fast spin-echo images obtained at baseline, pre-exercise, and postexercise conditions. Measures of the mean height and the mean sagittal area of lumbar IVDs (L1-L2 to L4-L5) were compared for two segmentation approaches: a conventional manual method (10-15 minutes to process one IVD) and a specifically developed semiautomated method (requiring only a few mouse clicks to process each subject). Both methods showed strong test-retest reproducibility evaluated on baseline and pre-exercise examinations with strong intraclass correlations for the semiautomated and manual methods for mean IVD height (intraclass correlation coefficient [ICC]=0.99, 0.98) and mean IVD area (ICC=0.98, 0.99), respectively. A bias (average deviation) of 0.38 mm (4.1%, 95% confidence interval 0.18-0.59 mm) was observed between the manual and semiautomated methods for the IVD height, whereas there was no statistically significant difference for the mean IVD area (0.1%±3.5%). The semiautomated and manual methods both detected significant exercise-induced changes in IVD height (0.20 and 0.28 mm) and mean IVD area (5.7 and 8.3 mm(2)), respectively. The presented semiautomated method provides an alternative to time- and expertise-intensive manual procedures for analysis of larger, cross-sectional, interventional, and longitudinal MR studies for morphometric analyses of lumbar IVDs. Copyright © 2014 Elsevier Inc. All rights reserved.
Mechanized or hand operations: which is less expensive for small timber?
Robert Rummber; John Klepac
2002-01-01
Two harvesting systems, one manual post-and-rail and one small-scale cut-to-length harvester, were compared in a lodgepole pine thinning. Elemental time study data were collected, along with estimates of residual stand damage. The harvester was about as productive as a manual crew of five. For material 5" and larger, the cost for felling, processing and piling...
ERIC Educational Resources Information Center
Newman, Bernie S.; Dannenfelser, Paul L.; Clemmons, Valarie
2007-01-01
Social workers recognize the necessity of using the "Diagnostic and Statistical Manual of Mental Disorders" ("DSM"; American Psychiatric Association) but question its compatibility with social work education. The data in this study were compared with the data from P. R. Raffoul and K. A. Holmes (1986) regarding the extent to which the "DSM" was…
Worker productivity and herbicide usage for pine release with manual application methods
James H. Miller; G.R. Glover
1993-01-01
Abstract. Productivity, herbicide usage, and costs of manually-applied pine release treatments were examined with linear regression analysis and compared. Data came from a replicated study in a 3-year-old loblolly pine plantation in Alabamaâs Piedmont. Brush sawing had the highest labor costs but lowest total treatment costs. While of the...
Reents, Tilko; Jilek, Clemens; Schuster, Peter; Nölker, Georg; Koch-Büttner, Katharina; Ammar-Busch, Sonia; Semmler, Verena; Bourier, Felix; Kottmaier, Marc; Kornmayer, Marie; Brooks, Stephanie; Fichtner, Stephanie; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele
2017-12-01
Remote magnetic navigation (RMN) is attributed to diminish radiation exposure for both patient and operator performing catheter ablation for different arrhythmia substrates. The purpose of this prospective, randomized study was to compare RMN with manually guided catheter ablation for AV nodal reentrant tachycardia (AVNRT) regarding fluoroscopy time/dosage, acute and long-term efficacy as well as safety. A total of 218 patients with AVNRT undergoing catheter ablation at three centers (male 34%, mean age 50 ± 17 years) were randomized to a manual approach (n = 113) or RMN (n = 105) using the Niobe ® magnetic navigation system. The primary study endpoint was total fluoroscopy time/dosage for patient and operator at the end of the procedure. Secondary endpoints included acute success, procedure duration, complications and success rate after 6 months. Fluoroscopy time and dosage for the patient were significantly reduced in the RMN group compared to the manual group (6 ± 6 vs. 11 ± 10 min; p < 0.001 and 425 ± 558 vs. 751 ± 900 cGycm 2 , p = 0.002). A reduction in fluoroscopy time/dose also applied to the operator (3 ± 5 vs. 7 ± 9 min 209 ± 444 vs. 482 ± 689 cGycm 2 , p < 0.001). Procedure duration was significantly longer in the RMN group (88 ± 29 vs. 79 ± 29 min; p = 0.03) and crossover from the RMN group to manual ablation occurred in 7.6% of patients (7.6 vs. 0.1%; p = 0.02). Acute success was achieved in 100% of patients in both groups. Midterm success after 6 months was 97 vs. 98% (p = 0.67). No complications occurred in both groups. The use of RMN for catheter ablation of AVNRT compared to a manual approach results in a reduction of fluoroscopy time and dosage of about 50% for both patients and physicians. Acute and midterm success and safety are comparable. RMN is a good alternative to a manual approach for AVNRT ablation.
Application of statistical machine translation to public health information: a feasibility study.
Kirchhoff, Katrin; Turner, Anne M; Axelrod, Amittai; Saavedra, Francisco
2011-01-01
Accurate, understandable public health information is important for ensuring the health of the nation. The large portion of the US population with Limited English Proficiency is best served by translations of public-health information into other languages. However, a large number of health departments and primary care clinics face significant barriers to fulfilling federal mandates to provide multilingual materials to Limited English Proficiency individuals. This article presents a pilot study on the feasibility of using freely available statistical machine translation technology to translate health promotion materials. The authors gathered health-promotion materials in English from local and national public-health websites. Spanish versions were created by translating the documents using a freely available machine-translation website. Translations were rated for adequacy and fluency, analyzed for errors, manually corrected by a human posteditor, and compared with exclusively manual translations. Machine translation plus postediting took 15-53 min per document, compared to the reported days or even weeks for the standard translation process. A blind comparison of machine-assisted and human translations of six documents revealed overall equivalency between machine-translated and manually translated materials. The analysis of translation errors indicated that the most important errors were word-sense errors. The results indicate that machine translation plus postediting may be an effective method of producing multilingual health materials with equivalent quality but lower cost compared to manual translations.
Application of statistical machine translation to public health information: a feasibility study
Turner, Anne M; Axelrod, Amittai; Saavedra, Francisco
2011-01-01
Objective Accurate, understandable public health information is important for ensuring the health of the nation. The large portion of the US population with Limited English Proficiency is best served by translations of public-health information into other languages. However, a large number of health departments and primary care clinics face significant barriers to fulfilling federal mandates to provide multilingual materials to Limited English Proficiency individuals. This article presents a pilot study on the feasibility of using freely available statistical machine translation technology to translate health promotion materials. Design The authors gathered health-promotion materials in English from local and national public-health websites. Spanish versions were created by translating the documents using a freely available machine-translation website. Translations were rated for adequacy and fluency, analyzed for errors, manually corrected by a human posteditor, and compared with exclusively manual translations. Results Machine translation plus postediting took 15–53 min per document, compared to the reported days or even weeks for the standard translation process. A blind comparison of machine-assisted and human translations of six documents revealed overall equivalency between machine-translated and manually translated materials. The analysis of translation errors indicated that the most important errors were word-sense errors. Conclusion The results indicate that machine translation plus postediting may be an effective method of producing multilingual health materials with equivalent quality but lower cost compared to manual translations. PMID:21498805
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I.; Letts, Robyn F. R.; Pantanowitz, Adam; Rubin, David M.; Thomsen, Jesper S.; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron. PMID:26170896
Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D
2009-05-21
Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology.Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. http://www.clinicaltrials.gov identifier NCT00847769.
Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D
2009-01-01
Background Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology. Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. Methods/Design We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. Discussion This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. Trial Registration identifier NCT00847769. PMID:19460169
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets.
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I; Letts, Robyn F R; Pantanowitz, Adam; Rubin, David M; Thomsen, Jesper S; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron.
Patel, Mehul D; Rose, Kathryn M; Owens, Cindy R; Bang, Heejung; Kaufman, Jay S
2012-03-01
Occupational data are a common source of workplace exposure and socioeconomic information in epidemiologic research. We compared the performance of two occupation coding methods, an automated software and a manual coder, using occupation and industry titles from U.S. historical records. We collected parental occupational data from 1920-40s birth certificates, Census records, and city directories on 3,135 deceased individuals in the Atherosclerosis Risk in Communities (ARIC) study. Unique occupation-industry narratives were assigned codes by a manual coder and the Standardized Occupation and Industry Coding software program. We calculated agreement between coding methods of classification into major Census occupational groups. Automated coding software assigned codes to 71% of occupations and 76% of industries. Of this subset coded by software, 73% of occupation codes and 69% of industry codes matched between automated and manual coding. For major occupational groups, agreement improved to 89% (kappa = 0.86). Automated occupational coding is a cost-efficient alternative to manual coding. However, some manual coding is required to code incomplete information. We found substantial variability between coders in the assignment of occupations although not as large for major groups.
Tomlinson, Mathew James; Pooley, Karen; Simpson, Tracey; Newton, Thomas; Hopkisson, James; Jayaprakasan, Kannamanadias; Jayaprakasan, Rajisha; Naeem, Asad; Pridmore, Tony
2010-04-01
To determine the accuracy and precision of a novel computer-assisted sperm analysis (CASA) system by comparison with existing recommended manual methods. Prospective study using comparative measurements of sperm concentration and motility on latex beads and immotile and motile sperm. Tertiary referral fertility center with strong academic links. Sperm donors and male partners of couples attending for fertility investigations. None. Achievement of Accubead target value for high and low concentration suspensions. Repeatability as demonstrated by coefficients of variation and intraclass correlation coefficients. Correlation and limits of agreement between CASA and manual methods. The CASA measurements of latex beads and sperm concentrations demonstrated a high level of accuracy and repeatability. Repeated Accubead measurements attained the required target value (mean difference from target of 2.61% and 3.71% for high- and low-concentration suspensions, respectively) and were highly reproducible. Limits of agreement analysis suggested that manual and CASA counts compared directly could be deemed to be interchangeable. Manual and CASA motility measurements were highly correlated for grades a, b, and d but could not be deemed to be interchangeable, and manual motility estimates were consistently higher for motile sperm. The novel CASA system was able to provide semen quality measurements for sperm concentration and motility measurements which were at least as reliable as current manual methods. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Verhaeghe, C; Parot-Schinkel, E; Bouet, P E; Madzou, S; Biquard, F; Gillard, P; Descamps, P; Legendre, G
2018-02-14
The frequency of posterior presentations (occiput of the fetus towards the sacrum of the mother) in labor is approximately 20% and, of this, 5% remain posterior until the end of labor. These posterior presentations are associated with higher rates of cesarean section and instrumental delivery. Manual rotation of a posterior position in order to rotate the fetus to an anterior position has been proposed in order to reduce the rate of instrumental fetal delivery. No randomized study has compared the efficacy of this procedure to expectant management. We therefore propose a monocentric, interventional, randomized, prospective study to show the superiority of vaginal delivery rates using the manual rotation of the posterior position at full dilation over expectant management. Ultrasound imaging of the presentation will be performed at full dilation on all the singleton pregnancies for which a clinical suspicion of a posterior position was raised at more than 37 weeks' gestation (WG). In the event of an ultrasound confirming a posterior position, the patient will be randomized into an experimental group (manual rotation) or a control group (expectative management with no rotation). For a power of 90% and the hypothesis that vaginal deliveries will increase by 20%, (10% of patients lost to follow-up) 238 patients will need to be included in the study. The primary endpoint will be the rate of spontaneous vaginal deliveries (expected rate without rotation: 60%). The secondary endpoints will be the rate of fetal extractions (cesarean or instrumental) and the maternal and fetal morbidity and mortality rates. The intent-to-treat study will be conducted over 24 months. Recruitment started in February 2017. To achieve the primary objective, we will perform a test comparing the number of spontaneous vaginal deliveries in the two groups using Pearson's chi-squared test (provided that the conditions for using this test are satisfactory in terms of numbers). In the event that this test cannot be performed, we will use Fisher's exact test. Given that the efficacy of manual rotation has not been proven with a high level of evidence, the practice of this technique is not systematically recommended by scholarly societies and is, therefore, rarely performed by obstetric gynecologists. If our hypothesis regarding the superiority of manual rotation is confirmed, our study will help change delivery practices in cases of posterior fetal position. An increase in the rates of vaginal delivery will help decrease the short- and long-term rates of morbidity and mortality following cesarean section. Manual rotation is a simple and effective method with a success rate of almost 90%. Several preliminary studies have shown that manual rotation is associated with reduced rates for fetal extraction and maternal complications: Shaffer has shown that the cesarean section rate is lower in patients for whom a manual rotation is performed successfully (2%) with a 9% rate of cesarean sections when manual rotation is performed versus 41% when it is not performed. Le Ray has shown that manual rotation significantly reduces vaginal delivery rates via fetal extraction (23.2% vs 38.7%, p < 0.01). However, manual rotation is not systematically performed due to the absence of proof of its efficacy in retrospective studies and quasi-experimental before/after studies. ClinicalTrials.gov, Identifier: NCT03009435 . Registered on 30 December 2016.
Bengtsson, C; Nordmark, B; Klareskog, L; Lundberg, I; Alfredsson, L; the, E
2005-01-01
Objective: To study whether formal education and occupational class are associated with incidence of rheumatoid arthritis overall and with the incidence of the two major subgroups of rheumatoid arthritis—seropositive (RF+) and seronegative (RF–) disease. Methods: 930 cases and 1126 controls participated in a population based case–control study using incident cases of rheumatoid arthritis, carried out in Sweden during the period May 1996 to June 2001. The relative risk (RR) of developing rheumatoid arthritis with 95% confidence interval (CI) was calculated for different levels of formal education compared with university degree and for different occupational classes compared with higher non-manual employees. Results: Subjects without a university degree had an increased risk of rheumatoid arthritis compared with those with a university degree (RR = 1.4 (95% CI, 1.2 to 1.8)). For manual employees, assistant and intermediate non-manual employees together, the risk of developing rheumatoid arthritis was about 20% more than for non-manual employees. These increased risks were more pronounced for RF+ than for RF– rheumatoid arthritis and were mainly confined to women. Smoking could not of its own explain the observed associations between risk of rheumatoid arthritis in different socioeconomic groups in Sweden. Conclusions: There was an association between high socioeconomic status and lower risk of rheumatoid arthritis in a population based investigation that was representative for the Swedish population. The study shows that as yet unexplained environmental or lifestyle factors, or both, influence the risk of rheumatoid arthritis, even in the relatively egalitarian Swedish society. PMID:15843455
Islam, Asef; Oldham, Michael J; Wexler, Anthony S
2017-11-01
Mammalian lungs are comprised of large numbers of tracheobronchial airways that transition from the trachea to alveoli. Studies as wide ranging as pollutant deposition and lung development rely on accurate characterization of these airways. Advancements in CT imaging and the value of computational approaches in eliminating the burden of manual measurement are providing increased efficiency in obtaining this geometric data. In this study, we compare an automated method to a manual one for the first six generations of three Balb/c mouse lungs. We find good agreement between manual and automated methods and that much of the disagreement can be attributed to method precision. Using the automated method, we then provide anatomical data for the entire tracheobronchial airway tree from three Balb/C mice. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:2046-2057, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Read, Emma K; Vallevand, Andrea; Farrell, Robin M
2016-01-01
This paper describes the development and evaluation of training intended to enhance students' performance on their first live-animal ovariohysterectomy (OVH). Cognitive task analysis informed a seven-page lab manual, 30-minute video, and 46-item OVH checklist (categorized into nine surgery components and three phases of surgery). We compared two spay simulator models (higher-fidelity silicone versus lower-fidelity cloth and foam). Third-year veterinary students were randomly assigned to a training intervention: lab manual and video only; lab manual, video, and $675 silicone-based model; lab manual, video, and $64 cloth and foam model. We then assessed transfer of training to a live-animal OVH. Chi-square analyses determined statistically significant differences between the interventions on four of nine surgery components, all three phases of surgery, and overall score. Odds ratio analyses indicated that training with a spay model improved the odds of attaining an excellent or good rating on 25 of 46 checklist items, six of nine surgery components, all three phases of surgery, and the overall score. Odds ratio analyses comparing the spay models indicated an advantage for the $675 silicon-based model on only 6 of 46 checklist items, three of nine surgery components, and one phase of surgery. Training with a spay model improved performance when compared to training with a manual and video only. Results suggested that training with a lower-fidelity/cost model might be as effective when compared to a higher-fidelity/cost model. Further research is required to investigate simulator fidelity and costs on transfer of training to the operational environment.
Active learning reduces annotation time for clinical concept extraction.
Kholghi, Mahnoosh; Sitbon, Laurianne; Zuccon, Guido; Nguyen, Anthony
2017-10-01
To investigate: (1) the annotation time savings by various active learning query strategies compared to supervised learning and a random sampling baseline, and (2) the benefits of active learning-assisted pre-annotations in accelerating the manual annotation process compared to de novo annotation. There are 73 and 120 discharge summary reports provided by Beth Israel institute in the train and test sets of the concept extraction task in the i2b2/VA 2010 challenge, respectively. The 73 reports were used in user study experiments for manual annotation. First, all sequences within the 73 reports were manually annotated from scratch. Next, active learning models were built to generate pre-annotations for the sequences selected by a query strategy. The annotation/reviewing time per sequence was recorded. The 120 test reports were used to measure the effectiveness of the active learning models. When annotating from scratch, active learning reduced the annotation time up to 35% and 28% compared to a fully supervised approach and a random sampling baseline, respectively. Reviewing active learning-assisted pre-annotations resulted in 20% further reduction of the annotation time when compared to de novo annotation. The number of concepts that require manual annotation is a good indicator of the annotation time for various active learning approaches as demonstrated by high correlation between time rate and concept annotation rate. Active learning has a key role in reducing the time required to manually annotate domain concepts from clinical free text, either when annotating from scratch or reviewing active learning-assisted pre-annotations. Copyright © 2017 Elsevier B.V. All rights reserved.
Groeneweg, Ruud; van Assen, Luite; Kropman, Hans; Leopold, Huco; Mulder, Jan; Smits-Engelsman, Bouwien C M; Ostelo, Raymond W J G; Oostendorp, Rob A B; van Tulder, Maurits W
2017-01-01
Manual therapy according to the School of Manual Therapy Utrecht (MTU) is a specific type of passive manual joint mobilization. MTU has not yet been systematically compared to other manual therapies and physical therapy. In this study the effectiveness of MTU is compared to physical therapy, particularly active exercise therapy (PT) in patients with non-specific neck pain. Patients neck pain, aged between 18-70 years, were included in a pragmatic randomized controlled trial with a one-year follow-up. Primary outcome measures were global perceived effect and functioning (Neck Disability Index), the secondary outcome was pain intensity (Numeric Rating Scale for Pain). Outcomes were measured at 3, 7, 13, 26 and 52 weeks. Multilevel analyses (intention-to-treat) were the primary analyses for overall between-group differences. Additional to the primary and secondary outcomes the number of treatment sessions of the MTU group and PT group was analyzed. Data were collected from September 2008 to February 2011. A total of 181 patients were included. Multilevel analyses showed no statistically significant overall differences at one year between the MTU and PT groups on any of the primary and secondary outcomes. The MTU group showed significantly lower treatment sessions compared to the PT group (respectively 3.1 vs. 5.9 after 7 weeks; 6.1 vs. 10.0 after 52 weeks). Patients with neck pain improved in both groups without statistical significantly or clinically relevant differences between the MTU and PT groups during one-year follow-up. ClinicalTrials.gov Identifier: NCT00713843.
The Efficacy of LUCAS in Prehospital Cardiac Arrest Scenarios: A Crossover Mannequin Study.
Gyory, Robert A; Buchle, Scott E; Rodgers, David; Lubin, Jeffrey S
2017-04-01
High-quality cardiopulmonary resuscitation (CPR) is critical for successful cardiac arrest outcomes. Mechanical devices may improve CPR quality. We simulated a prehospital cardiac arrest, including patient transport, and compared the performance of the LUCAS™ device, a mechanical chest compression-decompression system, to manual CPR. We hypothesized that because of the movement involved in transporting the patient, LUCAS would provide chest compressions more consistent with high-quality CPR guidelines. We performed a crossover-controlled study in which a recording mannequin was placed on the second floor of a building. An emergency medical services (EMS) crew responded, defibrillated, and provided either manual or LUCAS CPR. The team transported the mannequin through hallways and down stairs to an ambulance and drove to the hospital with CPR in progress. Critical events were manually timed while the mannequin recorded data on compressions. Twenty-three EMS providers participated. Median time to defibrillation was not different for LUCAS compared to manual CPR (p=0.97). LUCAS had a lower median number of compressions per minute (112/min vs. 125/min; IQR = 102-128 and 102-126 respectively; p<0.002), which was more consistent with current American Heart Association CPR guidelines, and percent adequate compression rate (71% vs. 40%; IQR = 21-93 and 12-88 respectively; p<0.002). In addition, LUCAS had a higher percent adequate depth (52% vs. 36%; IQR = 25-64 and 29-39 respectively; p<0.007) and lower percent total hands-off time (15% vs. 20%; IQR = 10-22 and 15-27 respectively; p<0.005). LUCAS performed no differently than manual CPR in median compression release depth, percent fully released compressions, median time hands off, or percent correct hand position. In our simulation, LUCAS had a higher rate of adequate compressions and decreased total hands-off time as compared to manual CPR. Chest compression quality may be better when using a mechanical device during patient movement in prehospital cardiac arrest patient.
Bhattacharya, Pratik; Van Stavern, Renee; Madhavan, Ramesh
2010-12-01
Use of resident case logs has been considered by the Residency Review Committee for Neurology of the Accreditation Council for Graduate Medical Education (ACGME). This study explores the effectiveness of a data-mining program for creating resident logs and compares the results to a manual data-entry system. Other potential applications of data mining to enhancing resident education are also explored. Patient notes dictated by residents were extracted from the Hospital Information System and analyzed using an unstructured mining program. History, examination and ICD codes were obtained and compared to the existing manual log. The automated data History, examination, and ICD codes were gathered for a 30-day period and compared to manual case logs. The automated method extracted all resident dictations with the dates of encounter and transcription. The automated data-miner processed information from all 19 residents, while only 4 residents logged manually. The manual method identified only broad categories of diseases; the major categories were stroke or vascular disorder 53 (27.6%), epilepsy 28 (14.7%), and pain syndromes 26 (13.5%). In the automated method, epilepsy 114 (21.1%), cerebral atherosclerosis 114 (21.1%), and headache 105 (19.4%) were the most frequent primary diagnoses, and headache 89 (16.5%), seizures 94 (17.4%), and low back pain 47 (9%) were the most common chief complaints. More detailed patient information such as tobacco use 227 (42%), alcohol use 205 (38%), and drug use 38 (7%) were extracted by the data-mining method. Manual case logs are time-consuming, provide limited information, and may be unpopular with residents. Data mining is a time-effective tool that may aid in the assessment of resident experience or the ACGME core competencies or in resident clinical research. More study of this method in larger numbers of residency programs is needed.
Nawasreh, Zakariya; Failla, Mathew; Marmon, Adam; Logerstedt, David; Snyder-Mackler, Lynn
2018-05-23
Performing physical activities on a compliant surface alters joint kinematics and increases joints stiffness. However, the effect of compliant surface on joint kinematics after ACL-rupture is yet unknown. To compare the effects of mechanical perturbation training with a compliant surface to manual perturbation training on joint kinematics after ACL-rupture. Sixteen level I/II athletes with ACL-rupture participated in this preliminary study. Eight patients received mechanical perturbation with compliant surface (Mechanical) and 8 patients received manual perturbation training (Manual). Patients completed standard gait analysis before (Pre) and after (Post) training. Significant group-by-time interactions were found for knee flexion angle at initial contact (IC) and peak knee flexion (PKF) (p<0.004), with manual group significantly increased knee flexion angle at IC and PKF (p<0.03). Main effects of group were found for hip flexion angle at IC (Manual:34.34+3.51°, Mechanical:27.68+4.08°, p = 0.011), hip rotation angle at PKE (Manual:-3.40+4.78°, Mechanical:5.43+4.78°, p < 0.0001), and knee adduction angle at PKE (Manual:-2.00+2.23°, Mechanical:0.55+2.23°, p = 0.039). Main effects of time were found for hip adduction angle at PKE (Pre:6.98+4.48°, Post:8.41+4.91°, p = 0.04), knee adduction angle at IC (Pre:-2.90+3.50°, Post:-0.62+2.58°, p = 0.03), ankle adduction angle at IC (Pre:2.16+3.54, Post:3.8+3.68, p = 0.008), and ankle flexion angle at PKF (Pre:-4.55+2.77°, Post:-2.39+3.48°, p = 0.01). Training on a compliant surface induces different effects on joint kinematics compared to manual perturbation training after ACL-rupture. Manual perturbation improved hip alignment and increased knee flexion angles, while mechanical training decreased knee flexion angles throughout the stance phase. Administering training on a compliant surface after ACL-rupture may help improving dynamic knee stability, however, long-term effects on knee health needs to be determined. Copyright © 2018 Elsevier B.V. All rights reserved.
Musculoskeletal Pain, Depression and Stress among Latino Manual Laborers in North Carolina
Tribble, Anna Grace; Summers, Phillip; Chen, Haiying; Quandt, Sara A.; Arcury, Thomas A.
2016-01-01
The jobs of Latino manual laborers place their mental and physical health at risk. This study evaluates the associations among musculoskeletal pain, mental health, and work organization in Latino manual laborers. Farmworkers and non-farmworkers (n=189) in North Carolina were interviewed for self-reported musculoskeletal pain, depressive symptoms, stress, work safety climate, and precarious job status. More non-farmworkers than farmworkers had neck and shoulder pain, but they did not differ in other areas of musculoskeletal pain. Depressive symptoms had a significant association with neck and shoulder pain (p<0.05). Precariousness had a significant association with back pain (p<0.05). Farmworker participants had H-2A visas and were afforded some protection compared to non-farmworker manual workers. Research is needed to improve policy that relieves pain and improves mental health for all Latino manual workers. PMID:26422551
Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming
2013-04-01
Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
Godwin, Marshall; Dawes, Martin; Kiss, Alexander; Tobe, Sheldon W; Grant, F Curry; Kaczorowski, Janusz
2011-01-01
Objective To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. Design Multi-site cluster randomised controlled trial. Setting Primary care practices in five cities in eastern Canada. Participants 555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community. Interventions Practices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient’s medical record before enrolment. Office blood pressure readings were compared before and after enrolment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure. Main outcome measure Difference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure. Results Cluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P<0.001). In the control group, routine manual office blood pressure before enrolment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrolment (P<0.001/P=0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P<0.001/P=0.02). On the first study visit after enrolment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (−2.3 (95% confidence interval −0.31 to −4.3)/−3.3 (−2.7 to −4.4)) was less (P=0.006/P=0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (−6.5 (−4.3 to −8.6)/−4.3 (−2.9 to −5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P<0.001) within group correlation (r=0.34/r=0.56) with awake ambulatory blood pressure after enrolment compared with manual office blood pressure versus awake ambulatory blood pressure before enrolment (r=0.10/r= 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r=0.56) was stronger (P<0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r=0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure. Conclusion In compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053. PMID:21300709
Occupational position and its relation to mental distress in a random sample of Danish residents.
Rugulies, Reiner; Madsen, Ida E H; Nielsen, Maj Britt D; Olsen, Lis R; Mortensen, Erik L; Bech, Per
2010-08-01
To analyze the distribution of depressive, anxiety, and somatization symptoms across different occupational positions in a random sample of Danish residents. The study sample consisted of 591 Danish residents (50% women), aged 20-65, drawn from an age- and gender-stratified random sample of the Danish population. Participants filled out a survey that included the 92 item version of the Hopkins Symptom Checklist (SCL-92). We categorized occupational position into seven groups: high- and low-grade non-manual workers, skilled and unskilled manual workers, high- and low-grade self-employed, and unemployed. Compared to the reference group of high-grade non-manual workers, the depressive symptom score was statistically significantly elevated among unskilled manual workers (P = 0.043) and the unemployed (P < 0.001), after adjustment for age, gender, cohabitation, life events, and low household income. The anxiety symptom score was elevated only among the unemployed (P = 0.004). The somatization symptom score was elevated among unskilled manual workers (P = 0.002), the low-grade self-employed (P = 0.023), and the unemployed (P = 0.001). When we analyzed caseness of severe symptoms, we found that unskilled manual workers (OR = 3.27, 95% CI = 1.06-10.04) and the unemployed (OR = 6.20, 95% CI = 1.98-19.42) had a higher prevalence of severe depressive symptoms, compared to the reference group of high-grade non-manual workers. The unemployed also had a higher prevalence of severe somatization symptoms (OR = 6.28, 95% CI = 1.39-28.46). Unskilled manual workers, the unemployed, and, to a lesser extent, the low-grade self-employed showed an increased level of mental distress. Activities to promote mental health in the Danish population should be directed toward these groups.
Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S
2016-05-01
The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Kantor, M; Zhu, X
2014-06-01
Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs.more » DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.« less
Manual Therapy for Hip Osteoarthritis: A Systematic Review and Meta-analysis.
Wang, Qiong; Wang, Teng-teng; Qi, Xiao-feng; Yao, Min; Cui, Xue-jun; Wang, Yong-jun; Liang, Qian-qian
2015-11-01
Hip osteoarthritis (HOA) is one of the major causes of disability in seniors and is costly to society. Manual therapy is one therapeutic approach to treating HOA. To assess the effect of manual therapy compared to the placebo or wait-list/no treatment or a minimal intervention control for HOA at post-treatment and short-, intermediate- and long-term follow-ups. A systematic review and meta-analysis of randomized controlled trials (RCTs). Hospital outpatient clinic in China. We searched PubMed, EMBASE, the Cochrane Library, CINAHL, ISI web of knowledge, and Chinese databases from the inception to October 2014 without language restrictions. References of systematic reviews and other related reviews, files in our department, and conference proceedings as grey literature were also screened by hand. RCTs compared manual therapy to the placebo, wait-list/no treatment or a minimal intervention control with an appropriate and precise description of randomization. Two reviewers independently conducted the search results identification, data extraction, and methodological quality assessment. We calculated the risk difference (RD) for dichotomous data and the mean difference (MD) or standardized mean difference (SMD) for continuous data in a fixed or random effect model. The primary outcomes were self-reported pain in the past week and physical function. The secondary outcomes were the quality of life, global perceived effect, patients' satisfaction, cost, and adverse events. Six studies involving 515 HOA patients were included. Five of the 6 studies ranked as high quality in the methodological assessment. Immediately post-treatment, there was low-quality evidence that manual therapy could not statistically significantly relieve pain (SMD: -0.07 [95%CI -0.38 to 0.24]); for physical function, a moderate quality of evidence showed that manual therapy could not improve the physical function significantly (SMD: 0.14 [95%CI -0.08 to 0.37]). We still found low-quality evidence that manual therapy did not benefit the patients in the global perceived effect (RD: 0.12 [95%CI -0.12 to 0.36]), and in terms of quality of life. In addition, the risks of patients in the manual therapy group was 0.13 times higher than that in the controls (RD: 0.13 [95%CI -0.05 to 0.31]) in the low-quality evidence studies. We could not find any evidence that manual therapy benefits the patients at short-, intermediate- or long-term follow-up. There were no studies reporting patients' satisfaction or cost. The limitations of this systematic review include the paucity of literature and inevitable heterogeneity between included studies. This review did not suggest there was enough evidence for manual therapy for the management of HOA. However, we are not confident in making such a conclusion due to the limitations listed above.
Johansson, Jarkko; Alakurtti, Kati; Joutsa, Juho; Tohka, Jussi; Ruotsalainen, Ulla; Rinne, Juha O
2016-10-01
The striatum is the primary target in regional C-raclopride-PET studies, and despite its small volume, it contains several functional and anatomical subregions. The outcome of the quantitative dopamine receptor study using C-raclopride-PET depends heavily on the quality of the region-of-interest (ROI) definition of these subregions. The aim of this study was to evaluate subregional analysis techniques because new approaches have emerged, but have not yet been compared directly. In this paper, we compared manual ROI delineation with several automatic methods. The automatic methods used either direct clustering of the PET image or individualization of chosen brain atlases on the basis of MRI or PET image normalization. State-of-the-art normalization methods and atlases were applied, including those provided in the FreeSurfer, Statistical Parametric Mapping8, and FSL software packages. Evaluation of the automatic methods was based on voxel-wise congruity with the manual delineations and the test-retest variability and reliability of the outcome measures using data from seven healthy male participants who were scanned twice with C-raclopride-PET on the same day. The results show that both manual and automatic methods can be used to define striatal subregions. Although most of the methods performed well with respect to the test-retest variability and reliability of binding potential, the smallest average test-retest variability and SEM were obtained using a connectivity-based atlas and PET normalization (test-retest variability=4.5%, SEM=0.17). The current state-of-the-art automatic ROI methods can be considered good alternatives for subjective and laborious manual segmentation in C-raclopride-PET studies.
Kassab, Safa; Pietrzak, William S
2014-01-01
Traditional manual instruments for total knee arthroplasty are associated with a malalignment rate of nearly 30%. Patient-specific positioning guides, developed to help address alignment, may also influence other intraoperative factors. This study compared a consecutive series of 270 Vanguard total knee replacements performed with Signature patient-specific positioning guides (study group) to a consecutive series of 595 similar knee replacements performed with manual instrumentation (control group). The study group averaged 16.7 fewer minutes in the operating room (p < .001), utilized tibial inserts that averaged 0.4 mm thinner with a smaller proportion of "thick" tibial inserts (14-18 mm) (p < .001), and required fewer transfusions (p = .022). The Signature-derived surgical plan accurately predicted correct femoral and tibial component sizes in 86.3% and 70.3% of the cases, respectively. These rates increased to 99.3% and 99.2%, respectively, for accuracy to within one size of the surgical plan, similar to published values for manual instrumentation.
Kim, Bong Hyun; Kim, Kyuseok; Nam, Hae Jeong
2017-01-31
Many previous studies of electroacupuncture used combined therapy of electroacupuncture and systemic manual acupuncture, so it was uncertain which treatment was effective. This study evaluated and compared the effects of systemic manual acupuncture, periauricular electroacupuncture and distal electroacupuncture for treating patients with tinnitus. A randomized, parallel, open-labeled exploratory trial was conducted. Subjects aged 20-75 years who had suffered from idiopathic tinnitus for > 2 weeks were recruited from May 2013 to April 2014. The subjects were divided into three groups by systemic manual acupuncture group (MA), periauricular electroacupuncture group (PE), and distal electroacupuncture group (DE). The groups were selected by random drawing. Nine acupoints (TE 17, TE21, SI19, GB2, GB8, ST36, ST37, TE3 and TE9), two periauricular acupoints (TE17 and TE21), and four distal acupoints (TE3, TE9, ST36, and ST37) were selected. The treatment sessions were performed twice weekly for a total of eight sessions over 4 weeks. Outcomes were the tinnitus handicap inventory (THI) score and the loud and uncomfortable visual analogue scales (VAS). Demographic and clinical characteristics of all participants were compared between the groups upon admission using one-way analysis of variance (ANOVA). One-way ANOVA was used to evaluate the THI, VAS loud , and VAS uncomfortable scores. The least significant difference test was used as a post-hoc test. Thirty-nine subjects were eligible and their data were analyzed. No difference in THI and VAS loudness scores was observed in between groups. The VAS uncomfortable scores decreased significantly in MA and DE compared with those in PE. Within the group, all three treatments showed some effect on THI, VAS loudness scores and VAS uncomfortable scores after treatment except DE in THI. There was no statistically significant difference between systemic manual acupuncture, periauricular electroacupuncture and distal electroacupuncture in tinnitus. However, all three treatments had some effect on tinnitus within the group before and after treatment. Systemic manual acupuncture and distal electroacupuncture have some effect on VAS uncomfortable . KCT0001991 by CRIS (Clinical Research Information Service), 2016-8-1, retrospectively registered.
ERIC Educational Resources Information Center
Gao, Yuan; Liu, Tzu-Chien; Paas, Fred
2016-01-01
This study compared the effects of effortless selection of target plants using quick respond (QR) code technology to effortful manual search and selection of target plants on learning about plants in a mobile device supported learning environment. In addition, it was investigated whether the effectiveness of the 2 selection methods was…
Casanova, Marcia Spinelli; Haiter-Neto, Francisco; Bóscolo, Frab Norberto; de Almeida, Solange Maria
2006-01-01
The aim of this study was to compare the sensitometric properties of Insight and Ektaspeed Plus radiographic films manually and automatically processed using fresh and depleted chemical solutions. Ten sets of each type of film were obtained (1 set = 5 films), 5 sets being manually processed and 5 sets being automatically processed. A total of 100 films (50 Ektaspeed Plus and 50 Insight film) were exposed and developed. The first two sets of each film type were developed in fresh chemicals (one set per each type of processing), on the first day of the experiment. The other sets were processed in the same progressively depleted solutions once a week until the end of experiment, which was completed within 4 weeks. Characteristic curves were constructed to compare the sensitometric properties of the films: contrast, latitude and speed. Processing solution depletion had different effects on manually and automatically developed films, which was confirmed by the changes in the form of the characteristic curves in the third week of the automatic processing and fourth week of the manual processing. Ektaspeed Plus showed 11% reduction in contrast values for manual processing and 53% for automatic processing, while Insight contrast values showed a reduction of 25% and 59%, respectively. Insight film, however, showed lesser loss of speed and lesser increase of latitude than Ektaspeed Plus. In conclusion, chemical depletion in automatic film processing was faster than in manual developing. In depleted chemicals, both types of films had an increase in latitude values and a decrease in speed and contrast. Insight was more resistant than Ektaspeed Plus to decrease in speed and latitude when processed using older chemicals, whereas contrast in Ektaspeed Plus was comparatively more stable.
Cha, Dong Ik; Lee, Min Woo; Song, Kyoung Doo; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-06-01
To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.
Yeap, P L; Noble, D J; Harrison, K; Bates, A M; Burnet, N G; Jena, R; Romanchikova, M; Sutcliffe, M P F; Thomas, S J; Barnett, G C; Benson, R J; Jefferies, S J; Parker, M A
2017-07-12
To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.
NASA Astrophysics Data System (ADS)
Yeap, P. L.; Noble, D. J.; Harrison, K.; Bates, A. M.; Burnet, N. G.; Jena, R.; Romanchikova, M.; Sutcliffe, M. P. F.; Thomas, S. J.; Barnett, G. C.; Benson, R. J.; Jefferies, S. J.; Parker, M. A.
2017-08-01
To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is 0.759 +/- 0.003 , and the median DBC is (0.87 +/- 0.01 ) mm. An intra-observer comparison for the same scans gives a median CI of 0.820 +/- 0.002 and a DBC of (0.64 +/- 0.01 ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.
Chae, Soo Young; Suh, Sangil; Ryoo, Inseon; Park, Arim; Noh, Kyoung Jin; Shim, Hackjoon; Seol, Hae Young
2017-05-01
We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual segmentation. Twenty-nine patients with pathologically proven brain tumors who underwent preoperative WBCTP between August 2012 and February 2015 were included. Three perfusion parameters, arterial flow (AF), equivalent blood volume (EBV), and Patlak flow (PF, which is a measure of permeability of capillaries), of brain tumors were generated by a commercial software and then quantified volumetrically by NPerfusion, which also semi-automatically segmented tumor boundaries. The quantification was validated by comparison with that of manual segmentation in terms of the concordance correlation coefficient and Bland-Altman analysis. With NPerfusion, we successfully performed segmentation and quantified whole volumetric perfusion parameters of all 29 brain tumors that showed consistent perfusion trends with previous studies. The validation of the perfusion parameter quantification exhibited almost perfect agreement with manual segmentation, with Lin concordance correlation coefficients (ρ c ) for AF, EBV, and PF of 0.9988, 0.9994, and 0.9976, respectively. On Bland-Altman analysis, most differences between this software and manual segmentation on the commercial software were within the limit of agreement. NPerfusion successfully performs segmentation of brain tumors and calculates perfusion parameters of brain tumors. We validated this semi-automated segmentation software by comparing it with manual segmentation. NPerfusion can be used to calculate volumetric perfusion parameters of brain tumors from WBCTP.
Kim, Min-Hee; Yoo, Won-Gyu
2015-06-05
According to a recent research, manual working with high levels of static contraction, repetitive loads, or extreme working postures involving the neck and shoulder muscles causes an increased risk of neck and shoulder musculoskeletal disorders. We investigated the effects of the forwardly worktable position on head and shoulder angles and shoulder muscle activity in manual material handling tasks. The forward head and shoulder angles and the activity of upper trapezius, levator scapulae, and middle deltoid muscle activities of 15 workers were measured during performing of manual material handling in two tasks that required different forward head and shoulder angles. The second manual material task required a significantly increased forward head and shoulder angle. The upper trapezius and levator scapulae muscle activity in second manual material task was increased significantly compared with first manual material task. The middle deltoid muscle activity in second manual material task was not significantly different compared with first manual material task. Based on this result, the forward head and shoulder angles while performing manual work need to be considered in selection of the forward distance of a worktable form the body. The high level contractions of the neck and shoulder muscles correlated with neck and shoulder pain. Therefore, the forward distance of a worktable can be an important factor in preventing neck and shoulder pain in manual material handling workers.
Parmar, Chintan; Blezek, Daniel; Estepar, Raul San Jose; Pieper, Steve; Kim, John; Aerts, Hugo J. W. L.
2017-01-01
Purpose Accurate segmentation of lung nodules is crucial in the development of imaging biomarkers for predicting malignancy of the nodules. Manual segmentation is time consuming and affected by inter-observer variability. We evaluated the robustness and accuracy of a publically available semiautomatic segmentation algorithm that is implemented in the 3D Slicer Chest Imaging Platform (CIP) and compared it with the performance of manual segmentation. Methods CT images of 354 manually segmented nodules were downloaded from the LIDC database. Four radiologists performed the manual segmentation and assessed various nodule characteristics. The semiautomatic CIP segmentation was initialized using the centroid of the manual segmentations, thereby generating four contours for each nodule. The robustness of both segmentation methods was assessed using the region of uncertainty (δ) and Dice similarity index (DSI). The robustness of the segmentation methods was compared using the Wilcoxon-signed rank test (pWilcoxon<0.05). The Dice similarity index (DSIAgree) between the manual and CIP segmentations was computed to estimate the accuracy of the semiautomatic contours. Results The median computational time of the CIP segmentation was 10 s. The median CIP and manually segmented volumes were 477 ml and 309 ml, respectively. CIP segmentations were significantly more robust than manual segmentations (median δCIP = 14ml, median dsiCIP = 99% vs. median δmanual = 222ml, median dsimanual = 82%) with pWilcoxon~10−16. The agreement between CIP and manual segmentations had a median DSIAgree of 60%. While 13% (47/354) of the nodules did not require any manual adjustment, minor to substantial manual adjustments were needed for 87% (305/354) of the nodules. CIP segmentations were observed to perform poorly (median DSIAgree≈50%) for non-/sub-solid nodules with subtle appearances and poorly defined boundaries. Conclusion Semi-automatic CIP segmentation can potentially reduce the physician workload for 13% of nodules owing to its computational efficiency and superior stability compared to manual segmentation. Although manual adjustment is needed for many cases, CIP segmentation provides a preliminary contour for physicians as a starting point. PMID:28594880
Ho, Robin S T; Chung, Vincent C H; Wong, Charlene H L; Wu, Justin C Y; Wong, Samuel Y S; Wu, Irene X Y
2017-09-04
Prokinetics for functional dyspepsia (FD) have relatively higher number needed to treat values. Acupuncture and related therapies could be used as add-on or alternative. An overview of systematic reviews (SRs) and network meta-analyses (NMA) were performed to evaluate the comparative effectiveness of different acupuncture and related therapies. We conducted a comprehensive literature search for SRs of randomized controlled trials (RCTs) in eight international and Chinese databases. Data from eligible RCTs were extracted for random effect pairwise meta-analyses. NMA was used to explore the most effective treatment among acupuncture and related therapies used alone or as add-on to prokinetics, compared to prokinetics alone. From five SRs, 22 RCTs assessing various acupuncture and related therapies were included. No serious adverse events were reported. Two pairwise meta-analyses showed manual acupuncture has marginally stronger effect in alleviating global FD symptoms, compared to domperidone or itopride. Results from NMA showed combination of manual acupuncture and clebopride has the highest probability in alleviating patient reported global FD symptom. Combination of manual acupuncture and clebopride has the highest probability of being the most effective treatment for FD symptoms. Patients who are contraindicated for prokinetics may use manual acupuncture or moxibustion as alternative. Future confirmatory comparative effectiveness trials should compare clebopride add-on manual acupuncture with domperidone add-on manual acupuncture and moxibustion.
Regulation of dynamic postural control to attend manual steadiness constraints.
Teixeira, Luis Augusto; Coutinho, Joane Figueiredo Serpa; Coelho, Daniel Boari
2018-05-02
In daily living activities, performance of spatially accurate manual movements in upright stance depends on postural stability. In the present investigation, we aimed to evaluate the effect of the required manual steadiness (task constraint) on the regulation of dynamic postural control. A single group of young participants (n=20) were evaluated in the performance of a dual posturo-manual task of balancing on a platform oscillating in sinusoidal translations at 0.4 Hz (low) or 1 Hz (high) frequencies while stabilizing a cylinder on a handheld tray. Manual task constraint was manipulated by comparing the conditions of keeping the cylinder stationary on its flat or round side, corresponding to low and high manual task constraints, respectively. Results showed that in the low oscillation frequency the high manual task constraint led to lower oscillation amplitudes of the head, center of mass, and tray, in addition to higher relative phase values between ankle/hip-shoulder oscillatory rotations and between center of mass/center of pressure-feet oscillations as compared to values observed in the low manual task constraint. Further analyses showed that the high manual task constraint also affected variables related to both postural (increased amplitudes of center of pressure oscillation) and manual (increased amplitude of shoulder rotations) task components in the high oscillation frequency. These results suggest that control of a dynamic posturo-manual task is modulated in distinct parameters to attend the required manual steadiness in a complex and flexible way.
Cabrera-Martos, I; Valenza, M C; Valenza-Demet, G; Benítez-Feliponi, A; Robles-Vizcaíno, C; Ruiz-Extremera, A
2016-11-01
Despite growing evidence regarding nonsynostotic plagiocephaly and their repercussions on motor development, there is little evidence to support the use of manual therapy as an adjuvant option. The aim of this study was to evaluate the effects of a therapeutic approach based on manual therapy as an adjuvant option on treatment duration and motor development in infants with severe nonsynostotic plagiocephaly. This is a randomised controlled pilot study. The study was conducted at a university hospital. Forty-six infants with severe nonsynostotic plagiocephaly (types 4-5 of the Argenta scale) referred to the Early Care and Monitoring Unit were randomly allocated to a control group receiving standard treatment (repositioning and an orthotic helmet) or to an experimental group treated with manual therapy added to standard treatment. Infants were discharged when the correction of the asymmetry was optimal taken into account the previous clinical characteristics. The outcome measures were treatment duration and motor development assessed with the Alberta Infant Motor Scale (AIMS) at baseline and at discharge. Asymmetry after the treatment was minimal (type 0 or 1 according to the Argenta scale) in both groups. A comparative analysis showed that treatment duration was significantly shorter (p < 0.001) in the experimental group (109.84 ± 14.45 days) compared to the control group (148.65 ± 11.53 days). The motor behaviour was normal (scores above the 16th percentile of the AIMS) in all the infants after the treatment. Manual therapy added to standard treatment reduces the treatment duration in infants with severe nonsynostotic plagiocephaly.
Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea
2017-04-01
Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.
Gabbay, I E; Bahar, I; Nahum, Y; Livny, E
2017-08-01
Descemet's membrane endothelial keratoplasty (DMEK) involves removal of the recipient's Descemet membrane (DM) prior to transplanting the donor's DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host's DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS. We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC. Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p < 0.05), but did not differ from one another statistically. DM stripping during posterior lamellar surgery is imperative for favorable post-operative results and prevention of complications. Performing this step under air in the AC contributes to better visualization and an efficient surgery.
Highly automated driving, secondary task performance, and driver state.
Merat, Natasha; Jamson, A Hamish; Lai, Frank C H; Carsten, Oliver
2012-10-01
A driving simulator study compared the effect of changes in workload on performance in manual and highly automated driving. Changes in driver state were also observed by examining variations in blink patterns. With the addition of a greater number of advanced driver assistance systems in vehicles, the driver's role is likely to alter in the future from an operator in manual driving to a supervisor of highly automated cars. Understanding the implications of such advancements on drivers and road safety is important. A total of 50 participants were recruited for this study and drove the simulator in both manual and highly automated mode. As well as comparing the effect of adjustments in driving-related workload on performance, the effect of a secondary Twenty Questions Task was also investigated. In the absence of the secondary task, drivers' response to critical incidents was similar in manual and highly automated driving conditions. The worst performance was observed when drivers were required to regain control of driving in the automated mode while distracted by the secondary task. Blink frequency patterns were more consistent for manual than automated driving but were generally suppressed during conditions of high workload. Highly automated driving did not have a deleterious effect on driver performance, when attention was not diverted to the distracting secondary task. As the number of systems implemented in cars increases, an understanding of the implications of such automation on drivers' situation awareness, workload, and ability to remain engaged with the driving task is important.
Cook, Chad; Learman, Ken; Houghton, Steve; Showalter, Christopher; O'Halloran, Bryan
2014-02-01
Shoulder impingement syndrome (SIS) is a complex, multi-factorial problem that is treated with a variety of different conservative options. One conservative option that has shown effectiveness is manual therapy to the thoracic spine. Another option, manual therapy to the cervical spine, has been studied only once with good results, evaluating short-term outcomes, in a small sample size. The purpose of this study was to investigate the benefit of neck manual therapy for patients with SIS. The study was a randomised, single blinded, clinical trial where both groups received pragmatic, evidence-based treatment to the shoulder and one group received neck manual therapy. Subjects with neck pain were excluded from the study. Comparative pain, disability, rate of recovery and patient acceptable symptom state (PASS) measures were analyzed on the 68 subjects seen over an average of 56.1 days (standard deviation (SD)=55.4). Eighty-six percent of the sample reported an acceptable change on the PASS at discharge. There were no between-groups differences in those who did or did not receive neck manual therapy; however, both groups demonstrated significant within-groups improvements. On average both groups improved 59.7% (SD=25.1) for pain and 53.5% (SD=40.2) for the Quick Disabilities of the Shoulder and Hand Questionnaire (QuickDASH) from baseline. This study found no value when neck manual therapy was added to the treatment of SIS. Reasons may include the lack of therapeutic dosage provided for the manual therapy approach or the lack of benefit to treating the neck in subjects with SIS who do not have concomitant neck problems. Copyright © 2013 Elsevier Ltd. All rights reserved.
Trnková, Petra; Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2010-12-01
The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning.
Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2011-01-01
Purpose The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. Material and methods For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. Results HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. Conclusions HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning. PMID:27853479
Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K
2011-04-01
Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual measurements, while interobserver APAs ranged from 91% to 96% for QMA versus 57% to 63% for digitized manual measurements. The use of QMA software substantially improved the reliability of lumbar intervertebral measurements and the classification of instability based on flexion-extension radiographs.
Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki
2017-09-01
The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to significantly higher arterial enhancement (P = 0.031) and less superimposition of nontargeted enhancement (P = 0.001). Visibility of bolus transition on 4D MRA was significantly better with power injection than with manual injection (P = 0.031). Compared with manual injection, power injection provides more standardized bolus shapes and higher image quality due to higher arterial enhancement and less superimposition of nontargeted vessels.
Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M
2014-06-01
This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
SINGH, Sumita; UPPOOR, Ashita; NAYAK, Dilip
2012-01-01
Objectives The debridement of diseased root surface is usually performed by mechanical scaling and root planing using manual and power driven instruments. Many new designs in ultrasonic powered scaling tips have been developed. However, their effectiveness as compared to manual curettes has always been debatable. Thus, the objective of this in vitro study was to comparatively evaluate the efficacy of manual, magnetostrictive and piezoelectric ultrasonic instrumentation on periodontally involved extracted teeth using profilometer and scanning electron microscope (SEM). Material and Methods 30 periodontally involved extracted human teeth were divided into 3 groups. The teeth were instrumented with hand and ultrasonic instruments resembling clinical application. In Group A all teeth were scaled with a new universal hand curette (Hu Friedy Gracey After Five Vision curette; Hu Friedy, Chicago, USA). In Group B CavitronTM FSI - SLITM ultrasonic device with focused spray slimline inserts (Dentsply International Inc., York, PA, USA) were used. In Group C teeth were scaled with an EMS piezoelectric ultrasonic device with prototype modified PS inserts. The surfaces were analyzed by a Precision profilometer to measure the surface roughness (Ra value in µm) consecutively before and after the instrumentation. The samples were examined under SEM at magnifications ranging from 17x to 300x and 600x. Results The mean Ra values (µm) before and after instrumentation in all the three groups A, B and C were tabulated. After statistically analyzing the data, no significant difference was observed in the three experimental groups. Though there was a decrease in the percentage reduction of Ra values consecutively from group A to C. Conclusion Within the limits of the present study, given that the manual, magnetostrictive and piezoelectric ultrasonic instruments produce the same surface roughness, it can be concluded that their efficacy for creating a biologically compatible surface of periodontally diseased teeth is similar. PMID:22437673
Bayesian decision support for coding occupational injury data.
Nanda, Gaurav; Grattan, Kathleen M; Chu, MyDzung T; Davis, Letitia K; Lehto, Mark R
2016-06-01
Studies on autocoding injury data have found that machine learning algorithms perform well for categories that occur frequently but often struggle with rare categories. Therefore, manual coding, although resource-intensive, cannot be eliminated. We propose a Bayesian decision support system to autocode a large portion of the data, filter cases for manual review, and assist human coders by presenting them top k prediction choices and a confusion matrix of predictions from Bayesian models. We studied the prediction performance of Single-Word (SW) and Two-Word-Sequence (TW) Naïve Bayes models on a sample of data from the 2011 Survey of Occupational Injury and Illness (SOII). We used the agreement in prediction results of SW and TW models, and various prediction strength thresholds for autocoding and filtering cases for manual review. We also studied the sensitivity of the top k predictions of the SW model, TW model, and SW-TW combination, and then compared the accuracy of the manually assigned codes to SOII data with that of the proposed system. The accuracy of the proposed system, assuming well-trained coders reviewing a subset of only 26% of cases flagged for review, was estimated to be comparable (86.5%) to the accuracy of the original coding of the data set (range: 73%-86.8%). Overall, the TW model had higher sensitivity than the SW model, and the accuracy of the prediction results increased when the two models agreed, and for higher prediction strength thresholds. The sensitivity of the top five predictions was 93%. The proposed system seems promising for coding injury data as it offers comparable accuracy and less manual coding. Accurate and timely coded occupational injury data is useful for surveillance as well as prevention activities that aim to make workplaces safer. Copyright © 2016 Elsevier Ltd and National Safety Council. All rights reserved.
Trehan, Mridula; Sharma, Sunil; Jharwal, Vikas; Rathore, Nidhi
2015-01-01
ABSTRACT Introduction: Maintenance of good oral hygiene is important for patients undergoing fixed orthodontic treatment. Aim: The aim of this study was to evaluate the effectiveness of a manual orthodontic toothbrush, powered toothbrush with oscillating head and sonic toothbrush in controlling plaque, gingivitis and interdental bleeding in patients undergoing fixed orthodontic treatment, and to compare their relative efficacy. Materials and methods: Sixty subjects, who were to receive orthodontic treatment with both upper and lower fixed appliances, were randomly divided into three study groups, with 20 patients in each group. Groups I to III were given manual orthodontic, powered and sonic toothbrushes, respectively. Plaque index (PI), gingival index (GI) and interdental bleeding index were scored to assess the level of plaque accumulation, gingival health and interdental bleeding at baseline; 4 and 8 weeks recall visits after fixed appliance bonding. Paired t-tests and one-way analysis of variance (ANOVA) tests were used for intragroup and intergroup comparisons. The level of statistical significance was set at p < 0.05. Results: This study showed that a significant reduction in all the three indices scores was found from baseline to 4 and 8 weeks in group III. On intergroup comparison, no statistically significant differences were detected between the three groups for any of the parameters assessed. Conclusion: On intragroup comparison, sonic brushes performed superiorly in reducing gingivitis, plaque and interdental bleeding as compared to the manual orthodontic and powered brushes. On intergroup comparison, the relative comparative effectiveness was found to be similar for all the three brushes. How to cite this article: Sharma R, Trehan M, Sharma S, Jharwal V, Rathore N. Comparison of Effectiveness of Manual Orthodontic, Powered and Sonic Toothbrushes on Oral Hygiene of Fixed Orthodontic Patients. Int J Clin Pediatr Dent 2015;8(3):181-189. PMID:26628852
Cottenden, Jennielee; Filter, Emily R; Cottreau, Jon; Moore, David; Bullock, Martin; Huang, Weei-Yuarn; Arnason, Thomas
2018-03-01
- Pathologists routinely assess Ki67 immunohistochemistry to grade gastrointestinal and pancreatic neuroendocrine tumors. Unfortunately, manual counts of the Ki67 index are very time consuming and eyeball estimation has been criticized as unreliable. Manual Ki67 counts performed by cytotechnologists could potentially save pathologist time and improve accuracy. - To assess the concordance between manual Ki67 index counts performed by cytotechnologists versus eyeball estimates and manual Ki67 counts by pathologists. - One Ki67 immunohistochemical stain was retrieved from each of 18 archived gastrointestinal or pancreatic neuroendocrine tumor resections. We compared pathologists' Ki67 eyeball estimates on glass slides and printed color images with manual counts performed by 3 cytotechnologists and gold standard manual Ki67 index counts by 3 pathologists. - Tumor grade agreement between pathologist image eyeball estimate and gold standard pathologist manual count was fair (κ = 0.31; 95% CI, 0.030-0.60). In 9 of 20 cases (45%), the mean pathologist eyeball estimate was 1 grade higher than the mean pathologist manual count. There was almost perfect agreement in classifying tumor grade between the mean cytotechnologist manual count and the mean pathologist manual count (κ = 0.910; 95% CI, 0.697-1.00). In 20 cases, there was only 1 grade disagreement between the 2 methods. Eyeball estimation by pathologists required less than 1 minute, whereas manual counts by pathologists required a mean of 17 minutes per case. - Eyeball estimation of the Ki67 index has a high rate of tumor grade misclassification compared with manual counting. Cytotechnologist manual counts are accurate and save pathologist time.
Zakkar, Mustafa; Kanagasabay, Robin; Hunt, Ian
2014-01-01
A best evidence topic in cardiothoracic surgery was written according to a structured protocol. The question addressed was whether manual closure of the bronchial stump is safer with lower failure rates than mechanical closure using a stapling device following anatomical lung resection. One hundred and twenty-nine papers were identified using the search below. Eight papers presented the best evidence to answer the clinical question as they included sufficient number of patients to reach conclusions regarding the issues of interest for this review. Complications, complication rates and operation time were included in the assessment. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. When looking at manual vs mechanical staples, it was noted that stapler failure can occur in around 4% of cases. The rate of bronchopleural fistula (BPF) development varied more in patients who underwent manual closure (1.5–12.5%) than in patients who underwent mechanical closure (1–5.7%). Although most of the studies reviewed showed no statistical differences between manual and mechanical closure in terms of BPF development, one study, however, showed that manual closure was significantly associated with lower numbers of postoperative BPF, while another study showed that mechanical closure is significantly associated with lower incidence of BPF. When looking at the role of the learning curve and training opportunities, it seems that the surgeon's inexperience when using mechanical staples can contribute to BPF development. A surgeon's experience can play a major role in the prevention of BPF development in patients having manual closure. Manual closure can provide a cheap and reliable technique when compared with costs incurred from using staplers, it is applicable in all situations and can be taught to surgeons in training with an acceptable risk. However, there is a lack of evidence to suggest that manual closure is better than mechanical stapler closure following anatomical lung resection. PMID:24351508
Laurence, Agathe; Wallez, Catherine; Blois-Heulin, Catherine
2011-09-01
Behavioural asymmetries reflect brain asymmetry in nonhuman primates (NHP) as in humans. By investigating manual laterality, researchers can study the evolution of brain hemisphere specialisation. Three dominant theories aim to establish an evolutionary scenario. The most recent theory relates different levels of manual laterality to task complexity. Our investigation aimed to evaluate the importance of two extrinsic factors (posture and the need for manual coordination) and two intrinsic factors (age and sex) on the expression of manual laterality by red-capped mangabeys. We observed 19 captive-born mangabeys, in spontaneous situations and under experimental conditions (seven experimental tasks varying in complexity). No directionality was observed in hand preference at the group level whatever the task. But our data revealed an effect of task complexity: more subjects were lateralised than not lateralised for the bipedal task and for the three most complex tasks. Finally, we evidenced an age and a sex effect. We compare our results with data for several other primate species and discuss them in the light of different manual laterality theories.
2012-01-01
Background Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. Methods 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. Results At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Conclusions Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. PMID:22361346
Homayounfar, Kia; Meis, Johanna; Jung, Klaus; Klosterhalfen, Bernd; Sprenger, Thilo; Conradi, Lena-Christin; Langer, Claus; Becker, Heinz
2012-02-23
Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.
Ali, Syed Shahzad; Ahmed, Syed Imran; Khan, Muhammad; Soomro, Rabail Rani
2014-07-01
To evaluate the effectiveness of Manual Therapy in comparison to Electrophysical agents in Knee Osteoarthritis. Total 50 patients with knee osteoarthritis were recruited from OPD of orthopedics civil hospital and Institute Of Physical Medicine & Rehabilitation, Dow University of Health Sciences Karachi. All those patients who fulfilled inclusion criteria were selected on voluntary basis. Selected patients were equally divided and randomly assigned into two groups with age and gender matching. The Manual therapy group received program of Maitland joint mobilization whereas Electrophysical Agent group received a program of TENS and cold pack. Both group received a program of exercise therapy as well. Patients received 3 treatment sessions per week for 4 successive weeks. Clinical assessment was performed using WOMAC index at baseline and on 12th treatment session. Both study groups showed clinically and statistically considerable improvements in WOMAC index. However, Related 2 sample t-test showed better clinical results in Manual Therapy group (p = 0.000) than Electrophysical Agents group (p = 0.008). The mean improvement in total WOMAC index was relatively higher in Manual Therapy group (22.36 ± 13.91) than Electrophysical Agent group (9.72 ± 6.10). This study concluded that manual therapy is clinically more effective in decreasing pain, stiffness and improving physical function in knee osteoarthritis.
Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko
2015-07-01
To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Gibbs, Vicki; Aldridge, Fiona; Chandler, Felicity; Witzlsperger, Ellen; Smith, Karen
2012-01-01
The proposed revision for Autism spectrum disorders (ASDs) in the Diagnostic and Statistical Manual of Mental Disorders-Fifth Edition (DSM-5) represents a shift from the Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition, Text Revision (DSM-IV-TR). As the proposed DSM-5 criteria require a higher minimum number of symptoms to be…
Movement Interferes with Visuospatial Working Memory during the Encoding: An ERP Study
Gunduz Can, Rumeysa; Schack, Thomas; Koester, Dirk
2017-01-01
The present study focuses on the functional interactions of cognition and manual action control. Particularly, we investigated the neurophysiological correlates of the dual-task costs of a manual-motor task (requiring grasping an object, holding it, and subsequently placing it on a target) for working memory (WM) domains (verbal and visuospatial) and processes (encoding and retrieval). Thirty participants were tested in a cognitive-motor dual-task paradigm, in which a single block (a verbal or visuospatial WM task) was compared with a dual block (concurrent performance of a WM task and a motor task). Event-related potentials (ERPs) were analyzed separately for the encoding and retrieval processes of verbal and visuospatial WM domains both in single and dual blocks. The behavioral analyses show that the motor task interfered with WM and decreased the memory performance. The performance decrease was larger for the visuospatial task compared with the verbal task, i.e., domain-specific memory costs were obtained. The ERP analyses show the domain-specific interference also at the neurophysiological level, which is further process-specific to encoding. That is, comparing the patterns of WM-related ERPs in the single block and dual block, we showed that visuospatial ERPs changed only for the encoding process when a motor task was performed at the same time. Generally, the present study provides evidence for domain- and process-specific interactions of a prepared manual-motor movement with WM (visuospatial domain during the encoding process). This study, therefore, provides an initial neurophysiological characterization of functional interactions of WM and manual actions in a cognitive-motor dual-task setting, and contributes to a better understanding of the neuro-cognitive mechanisms of motor action control. PMID:28611714
ERIC Educational Resources Information Center
Putten, Jim Vander; Nolen, Amanda L.
2010-01-01
This study compared qualitative research results obtained by manual constant comparative analysis with results obtained by computer software analysis of the same data. An investigated about issues of trustworthiness and accuracy ensued. Results indicated that the inductive constant comparative data analysis generated 51 codes and two coding levels…
Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
Bakan, Ebubekir; Ozturk, Nurinnisa; Baygutalp, Nurcan Kilic; Polat, Elif; Akpinar, Kadriye; Dorman, Emrullah; Polat, Harun; Bakan, Nuri
2016-01-01
Introduction Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. Materials and methods A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. Results The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. Conclusions The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. PMID:27812305
Association between heart rate variability and manual pulse rate.
Hart, John
2013-09-01
One model for neurological assessment in chiropractic pertains to autonomic variability, tested commonly with heart rate variability (HRV). Since HRV may not be convenient to use on all patient visits, more user-friendly methods may help fill-in the gaps. Accordingly, this study tests the association between manual pulse rate and heart rate variability. The manual rates were also compared to the heart rate derived from HRV. Forty-eight chiropractic students were examined with heart rate variability (SDNN and mean heart rate) and two manual radial pulse rate measurements. Inclusion criteria consisted of participants being chiropractic students. Exclusion criteria for 46 of the participants consisted of a body mass index being greater than 30, age greater than 35, and history of: a) dizziness upon standing, b) treatment of psychiatric disorders, and c) diabetes. No exclusion criteria were applied to the remaining two participants who were also convenience sample volunteers. Linear associations between the manual pulse rate methods and the two heart rate variability measures (SDNN and mean heart) were tested with Pearson's correlation and simple linear regression. Moderate strength inverse (expected) correlations were observed between both manual pulse rate methods and SDNN (r = -0.640, 95% CI -0.781, -0.435; r = -0.632, 95% CI -0.776, -0.425). Strong direct (expected) relationships were observed between the manual pulse rate methods and heart rate derived from HRV technology (r = 0.934, 95% CI 0.885, 0.962; r = 0.941, 95% CI 0.897, 0.966). Manual pulse rates may be a useful option for assessing autonomic variability. Furthermore, this study showed a strong relationship between manual pulse rates and heart rate derived from HRV technology.
Stapler suture of the pharynx after total laryngectomy.
Dedivitis, R A; Aires, F T; Pfuetzenreiter, E G; Castro, M A F; Guimarães, A V
2014-04-01
The use of a stapler for pharyngeal closure during total laryngectomy was first described in 1971. It provides rapid watertight closure without surgical field contamination. The objective of our study was to compare the incidence of pharyngocutaneous fistula after total laryngectomy with manual and mechanical closures of the pharynx. This was a non-randomised, prospective clinical study conducted at two tertiary medical centres from 1996 to 2011 including consecutive patients with laryngeal tumours who underwent total laryngectomy. We compared the incidence of pharyngocutaneous fistula between two groups of patients: in 20 patients, 75 mm linear stapler closure was applied, whereas in 67 patients a manual suture was used. Clinical data were compared between groups. The groups were statistically similar in terms of gender, age, diabetes mellitus, smoking and alcohol consumption and tumour site. The group of patients who underwent stapler-assisted pharyngeal closure had a higher number of patients with previous tracheotomy (p < 0.001) and previous chemoradiation (p < 0.001). The incidence of pharyngocutaneous fistula was 30% in the mechanical closure group and 20.9% in the manual suture group (p = 0.42). In conclusion the use of the stapler does not increase the rate of fistulae.
DEDIVITIS, R.A.; AIRES, F.T.; PFUETZENREITER, E.G.; CASTRO, M.A.F.; GUIMARÃES, A.V.
2014-01-01
SUMMARY The use of a stapler for pharyngeal closure during total laryngectomy was first described in 1971. It provides rapid watertight closure without surgical field contamination. The objective of our study was to compare the incidence of pharyngocutaneous fistula after total laryngectomy with manual and mechanical closures of the pharynx. This was a non-randomised, prospective clinical study conducted at two tertiary medical centres from 1996 to 2011 including consecutive patients with laryngeal tumours who underwent total laryngectomy. We compared the incidence of pharyngocutaneous fistula between two groups of patients: in 20 patients, 75 mm linear stapler closure was applied, whereas in 67 patients a manual suture was used. Clinical data were compared between groups. The groups were statistically similar in terms of gender, age, diabetes mellitus, smoking and alcohol consumption and tumour site. The group of patients who underwent stapler-assisted pharyngeal closure had a higher number of patients with previous tracheotomy (p < 0.001) and previous chemoradiation (p < 0.001). The incidence of pharyngocutaneous fistula was 30% in the mechanical closure group and 20.9% in the manual suture group (p = 0.42). In conclusion the use of the stapler does not increase the rate of fistulae. PMID:24843218
Evaluation of a treatment manual and workshops for disseminating, parent-child interaction therapy.
Herschell, Amy D; McNeil, Cheryl B; Urquiza, Anthony J; McGrath, Jean M; Zebell, Nancy M; Timmer, Susan G; Porter, Alissa
2009-01-01
This study's main purposes were to: (a) evaluate a treatment manual as a dissemination strategy, (b) compare two workshop formats for evidence-based treatment (EBT) training, and (c) provide preliminary data on therapist characteristics potentially associated with successful EBT adoption. Forty-two community-based clinicians were assigned to one of two training groups (didactic or experiential). Behavior observation and self-report data were collected at four time points. Results suggest that reading a treatment manual is useful, but not sufficient. Experiential and didactic training were equally effective in increasing knowledge, skill, and satisfaction; however, after a 2-day training, few participants demonstrated mastery of skills.
Bahl, R; Van de Venne, M; Macleod, M; Strachan, B; Murphy, D J
2013-11-01
To compare the maternal and neonatal morbidity associated with alternative instruments used to perform a mid-cavity rotational delivery. A prospective cohort study. Two university teaching hospitals in Scotland and England. Three hundred and eighty-one nulliparous women who had a mid-cavity rotational operative vaginal delivery. A data collection sheet was completed by the research team following delivery. Postpartum haemorrhage, third- and fourth-degree perineal tears, low cord pH, neonatal trauma, and failed or sequential operative vaginal delivery. One hundred and sixty-three women (42.8%) underwent manual rotation followed by non-rotational forceps delivery, 73 (19.1%) had a rotational vacuum delivery, and 145 (38.1%) delivered with the assistance of rotational (Kielland) forceps. The rates of postpartum haemorrhage were similar when comparing manual rotation with rotational vacuum (adjusted OR 1.42, 95% CI 0.66-3.98), and when comparing manual rotation with Kielland forceps (adjusted OR 1.22, 95% CI 0.71-2.88). The results were comparable for third- and fourth-degree perineal tears (adjusted OR 0.85, 95% CI 0.13-1.89; adjusted OR 0.94, 95% CI 0.39-1.82), low cord pH (adjusted OR 1.76, 95% CI 0.44-6.91; adjusted OR 1.12, 95% CI 0.44-2.83), neonatal trauma (adjusted OR 0.50, 95% CI 0.16-1.55; adjusted OR 3.25, 95% CI 0.65-16.17), and admission to the neonatal intensive care unit (adjusted OR 1.47, 95% CI 0.45-4.81; adjusted OR 1.04, 95% CI 0.49-2.19). The sequential use of instruments was less likely with manual rotation and forceps than with rotational vacuum delivery (0.6 versus 36.9%, OR 0.01, 95% CI 0.002-0.090). Maternal and perinatal outcomes are comparable with Kielland forceps, vacuum extraction, and manual rotation, with few serious adverse outcomes. With appropriate training mid-cavity rotational delivery can be practiced safely, including the use of Kielland forceps. © 2013 RCOG.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowder, C.; Hurley, T.
1981-03-01
An analysis is presented of five safety and health contractor manuals against the requirements of the FE OSH Manual (FE 5480.1), and a breakdown in chart form of how the manuals compare to each other is given. It is pointed out that the manuals are inadequate, but that site visits will be necessary to determine the actual comprehensiveness of the facilities' safety and health programs.
Limongi, Orlando; de Albuquerque, Diana Santana; Baratto Filho, Flares; Vanni, José Roberto; de Oliveira, Elias P Motcy; Barletta, Fernando Branco
2007-01-01
This in vitro study compared, using computed tomography (CT), the amount of dentin removed from root canal walls by manual and mechanical rotary instrumentation techniques. Forty mandibular incisors with dental crown and a single canal were selected. The teeth were randomly assigned to two groups, according to the technique used for root canal preparation: Group I - manual instrumentation with stainless steel files; Group II - mechanical instrumentation with RaCe rotary nickel-titanium instruments. In each tooth, root dentin thickness of the buccal, lingual, mesial and distal surfaces in the apical, middle and cervical thirds of the canal was measured (in mm) using a multislice CT scanner (Siemens Emotion, Duo). Data were stored in the SPSS v. 11.5 and SigmaPlot 2001 v. 7.101 softwares. After crown opening, working length was determined, root canals were instrumented and new CT scans were taken for assessment of root dentin thickness. Pre- and post-instrumentation data were compared and analyzed statistically by ANOVA and Tukey's post-hoc test for significant differences (p=0.05). Based on the findings of this study, it may be concluded that regarding dentin removal from root canal walls during instrumentation, neither of the techniques can be considered more effective than the other.
Cartwright, Michael S.; Walker, Francis O.; Blocker, Jill N.; Schulz, Mark R.; Arcury, Thomas A.; Grzywacz, Joseph G.; Mora, Dana; Chen, Haiying; Marín, Antonio J.; Quandt, Sara A.
2011-01-01
Objective To determine the prevalence of carpal tunnel syndrome (CTS) in Latino poultry processing workers. Methods Symptoms and nerve conduction studies were used to prospectively assess 287 Latino poultry processing workers and 226 Latinos in other manual labor occupations. Results The prevalence of CTS was higher in poultry processing (8.7%) compared to non-poultry manual workers (4.0%, p < 0.0001). The adjusted odds ratio for the prevalence of CTS in poultry workers was 2.51 (95% CI of 1.80 to 3.50) compared to non-poultry workers. Within the poultry workers, those who performed packing, sanitation, and chilling had a trend toward less CTS than those who performed tasks requiring more repetitive and strenuous hand movements. Discussion Latino poultry processing workers have a high prevalence of CTS, which likely results from the repetitive and strenuous nature of the work. PMID:22258161
Knutsson, Karl Anders; Rama, Paolo; Paganoni, Giorgio
2015-08-01
To evaluate the clinical findings and results of manual dissection deep anterior lamellar keratoplasty (DALK) compared to a modified big-bubble DALK technique in eyes affected by keratoconus. Sixty eyes of 60 patients with keratoconus were treated with one of the two surgical techniques manual DALK (n = 30); big-bubble DALK (n = 30). The main outcomes measured were visual acuity, corneal topographic parameters, thickness of residual stroma and endothelial cell density (ECD). Patients were examined postoperatively at 1 month, 6 months, 1 year and 1 month after suture removal. Final best spectacle-corrected visual acuity (BSCVA) measured 1 month after suture removal was 0.11 ± 0.08 LogMAR in the big-bubble group compared to 0.13 ± 0.08 in the manual DALK group (p = 0.227). In patients treated with the big-bubble technique without complications (Descemet's membrane completely bared), the stromal residue was not measureable. Mean stromal residual thickness in the manual DALK group was 30.50 ± 27.60 μm. Data analysis of the manual DALK group demonstrated a significant correlation between BSCVA and residual stromal thickness; lower residual stromal thickness correlated with better BSCVA values (Spearman ρ = 0.509, p = 0.018). Postoperative ECD was similar in both groups at all intervals, with no statistically significant differences. In both groups, ECD loss was only significant during the 1- to 6-month interval (p = 0.001 and p < 0.001 in the big-bubble DALK and manual DALK groups, respectively). Manual DALK provides comparable results to big-bubble DALK. Big-bubble DALK permits faster visual recovery and is a surgical technique, which can be easily converted to manual DALK in cases of unsuccessful 'big-bubble' formation. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Odland, Audun; Server, Andres; Saxhaug, Cathrine; Breivik, Birger; Groote, Rasmus; Vardal, Jonas; Larsson, Christopher; Bjørnerud, Atle
2015-11-01
Volumetric magnetic resonance imaging (MRI) is now widely available and routinely used in the evaluation of high-grade gliomas (HGGs). Ideally, volumetric measurements should be included in this evaluation. However, manual tumor segmentation is time-consuming and suffers from inter-observer variability. Thus, tools for semi-automatic tumor segmentation are needed. To present a semi-automatic method (SAM) for segmentation of HGGs and to compare this method with manual segmentation performed by experts. The inter-observer variability among experts manually segmenting HGGs using volumetric MRIs was also examined. Twenty patients with HGGs were included. All patients underwent surgical resection prior to inclusion. Each patient underwent several MRI examinations during and after adjuvant chemoradiation therapy. Three experts performed manual segmentation. The results of tumor segmentation by the experts and by the SAM were compared using Dice coefficients and kappa statistics. A relatively close agreement was seen among two of the experts and the SAM, while the third expert disagreed considerably with the other experts and the SAM. An important reason for this disagreement was a different interpretation of contrast enhancement as either surgically-induced or glioma-induced. The time required for manual tumor segmentation was an average of 16 min per scan. Editing of the tumor masks produced by the SAM required an average of less than 2 min per sample. Manual segmentation of HGG is very time-consuming and using the SAM could increase the efficiency of this process. However, the accuracy of the SAM ultimately depends on the expert doing the editing. Our study confirmed a considerable inter-observer variability among experts defining tumor volume from volumetric MRIs. © The Foundation Acta Radiologica 2014.
Cartwright, Michael S; Walker, Francis O; Newman, Jill C; Schulz, Mark R; Arcury, Thomas A; Grzywacz, Joseph G; Mora, Dana C; Chen, Haiying; Eaton, Bethany; Quandt, Sara A
2014-03-01
To determine the incidence of carpal tunnel syndrome (CTS) over 1 year in Latino poultry processing workers. Symptoms and nerve conduction studies were used to identify Latino poultry processing workers (106 wrists) and Latinos in other manual labor occupations (257 wrists) that did not have CTS at baseline, and these individuals were then evaluated in the same manner 1 year later. Based on wrists, the 1-year incidence of CTS was higher in poultry processing workers than non-poultry manual workers (19.8% vs. 11.7%, P = 0.022). Poultry workers had a higher odds (1.89; P = 0.089) of developing CTS over 1 year compared to non-poultry manual workers. Latino poultry processing workers have an incidence of CTS that is possibly higher than Latinos in other manual labor positions. Latino poultry workers' high absolute and relative risk of CTS likely results from the repetitive and strenuous nature of poultry processing work. © 2013 Wiley Periodicals, Inc.
2011-01-01
Background Global positioning systems (GPS) are increasingly being used in health research to determine the location of study participants. Combining GPS data with data collected via travel/activity diaries allows researchers to assess where people travel in conjunction with data about trip purpose and accompaniment. However, linking GPS and diary data is problematic and to date the only method has been to match the two datasets manually, which is time consuming and unlikely to be practical for larger data sets. This paper assesses the feasibility of a new sequence alignment method of linking GPS and travel diary data in comparison with the manual matching method. Methods GPS and travel diary data obtained from a study of children's independent mobility were linked using sequence alignment algorithms to test the proof of concept. Travel diaries were assessed for quality by counting the number of errors and inconsistencies in each participant's set of diaries. The success of the sequence alignment method was compared for higher versus lower quality travel diaries, and for accompanied versus unaccompanied trips. Time taken and percentage of trips matched were compared for the sequence alignment method and the manual method. Results The sequence alignment method matched 61.9% of all trips. Higher quality travel diaries were associated with higher match rates in both the sequence alignment and manual matching methods. The sequence alignment method performed almost as well as the manual method and was an order of magnitude faster. However, the sequence alignment method was less successful at fully matching trips and at matching unaccompanied trips. Conclusions Sequence alignment is a promising method of linking GPS and travel diary data in large population datasets, especially if limitations in the trip detection algorithm are addressed. PMID:22142322
Kaya Mutlu, Ebru; Ercin, Ersin; Razak Ozdıncler, Arzu; Ones, Nadir
2018-08-01
A broad spectrum of physical therapy exercise programs provides symptom relief and functional benefit for patients with knee OA. Manual physical therapy, including tailored exercise programs provide relatively higher level benefit that persists to one year. It is currently unknown if there are important differences in the effects of different manual physical therapy techniques for patients with knee OA and there are virtually no studies comparing manual physical therapy and electrotherapy modalities. The aim of the study was to compare long-term results between three treatment groups (mobilization with movements [MWMs], passive joint mobilization [PJM], and electrotherapy) to determine which treatment is most effective in patients with knee OA. A single-blind randomized clinical trial with parallel design was conducted in patients with knee OA. Seventy-two consecutive patients (mean age 56.11 ± 6.80 years) with bilateral knee OA were randomly assigned to one of three treatment groups: MWMs, PJM, and electrotherapy. All groups performed an exercise program and received 12 sessions. The primary outcome measures of the functional assessment were the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC) and Aggregated Locomotor Function (ALF) test scores. The secondary outcome measures were pain level, measured using a pressure algometer and a visual analogue scale (VAS), range of motion (ROM), measured using a digital goniometer, and muscle strength, evaluated with a handheld dynamometer. Patients were assessed before treatment, after treatment and after 1 year of follow-up. Patients receiving the manual physical therapy interventions consisting of either MWM or PJM demonstrated a greater decrease in VAS scores at rest, during functional activities, and during the night compared to those in the electrotherapy group from baseline to after the treatment (p < 0.05). This improvement continued at the 1-year follow-up (p < 0.05). The MWMs and PJM groups also showed significantly improved WOMAC and ALF scores, knee ROM and quadriceps muscle strength compared to those in the electrotherapy group from baseline to 1-year follow-up (p < 0.05). In the treatment of patients with knee OA, manual physical therapy consisting of either MWM or PJM provided superior benefit over electrotherapy in terms of pain level, knee ROM, quadriceps muscle strength, and functional level.
Cerebella segmentation on MR images of pediatric patients with medulloblastoma
NASA Astrophysics Data System (ADS)
Shan, Zu Y.; Ji, Qing; Glass, John; Gajjar, Amar; Reddick, Wilburn E.
2005-04-01
In this study, an automated method has been developed to identify the cerebellum from T1-weighted MR brain images of patients with medulloblastoma. A new objective function that is similar to Gibbs free energy in classic physics was defined; and the brain structure delineation was viewed as a process of minimizing Gibbs free energy. We used a rigid-body registration and an active contour (snake) method to minimize the Gibbs free energy in this study. The method was applied to 20 patient data sets to generate cerebellum images and volumetric results. The generated cerebellum images were compared with two manually drawn results. Strong correlations were found between the automatically and manually generated volumetric results, the correlation coefficients with each of manual results were 0.971 and 0.974, respectively. The average Jaccard similarities with each of two manual results were 0.89 and 0.88, respectively. The average Kappa indexes with each of two manual results were 0.94 and 0.93, respectively. These results showed this method was both robust and accurate for cerebellum segmentation. The method may be applied to various research and clinical investigation in which cerebellum segmentation and quantitative MR measurement of cerebellum are needed.
Hoeksma, Hugo L; Dekker, Joost; Ronday, H Karel; Heering, Annet; van der Lubbe, Nico; Vel, Cees; Breedveld, Ferdinand C; van den Ende, Cornelia H M
2004-10-15
To determine the effectiveness of a manual therapy program compared with an exercise therapy program in patients with osteoarthritis (OA) of the hip. A single-blind, randomized clinical trial of 109 hip OA patients was carried out in the outpatient clinic for physical therapy of a large hospital. The manual therapy program focused on specific manipulations and mobilization of the hip joint. The exercise therapy program focused on active exercises to improve muscle function and joint motion. The treatment period was 5 weeks (9 sessions). The primary outcome was general perceived improvement after treatment. Secondary outcomes included pain, hip function, walking speed, range of motion, and quality of life. Of 109 patients included in the study, 56 were allocated to manual therapy and 53 to exercise therapy. No major differences were found on baseline characteristics between groups. Success rates (primary outcome) after 5 weeks were 81% in the manual therapy group and 50% in the exercise group (odds ratio 1.92, 95% confidence interval 1.30, 2.60). Furthermore, patients in the manual therapy group had significantly better outcomes on pain, stiffness, hip function, and range of motion. Effects of manual therapy on the improvement of pain, hip function, and range of motion endured after 29 weeks. The effect of the manual therapy program on hip function is superior to the exercise therapy program in patients with OA of the hip.
Choi, Ja Young; Park, Jieun; Choi, Yoon Seong; Goh, Yu Ra; Park, Eun Sook
2018-07-01
The aim of the present study was to investigate communication function using classification systems and its association with other functional profiles, including gross motor function, manual ability, intellectual functioning, and brain magnetic resonance imaging (MRI) characteristics in children with cerebral palsy (CP). This study recruited 117 individuals with CP aged from 4 to 16 years. The Communication Function Classification System (CFCS), Viking Speech Scale (VSS), Speech Language Profile Groups (SLPG), Gross Motor Function Classification System (GMFCS), Manual Ability Classification System (MACS), and intellectual functioning were assessed in the children along with brain MRI categorization. Very strong relationships were noted among the VSS, CFCS, and SLPG, although these three communication systems provide complementary information, especially for children with mid-range communication impairment. These three communication classification systems were strongly related with the MACS, but moderately related with the GMFCS. Multiple logistic regression analysis indicated that manual ability and intellectual functioning were significantly related with VSS and CFCS function, whereas only intellectual functioning was significantly related with SLPG functioning in children with CP. Communication function in children with a periventricular white matter lesion (PVWL) varied widely. In the cases with a PVWL, poor functioning was more common on the SLPG, compared to the VSS and CFCS. Very strong relationships were noted among three communication classification systems that are closely related with intellectual ability. Compared to gross motor function, manual ability seemed more closely related with communication function in these children. © Copyright: Yonsei University College of Medicine 2018.
Emergency Manuals Improved Novice Physician Performance During Simulated ICU Emergencies
Wang, Jacob; Stiegler, Marjorie P.; Nguyen, Dung; Rebel, Annette; Isaak, Robert S.
2017-01-01
Background Emergency manuals, which are safety essentials in non-medical high-reliability organizations (e.g., aviation), have recently gained acceptance in critical medical environments. Of the existing emergency manuals in anesthesiology, most are geared towards intraoperative settings. Additionally, most evidence supporting their efficacy focuses on the study of physicians with at least some meaningful experience as a physician. Our aim was to evaluate whether an emergency manual would improve the performance of novice physicians (post-graduate year [PGY] 1 or first year resident) in managing a critical event in the intensive care unit (ICU). Methods PGY1 interns (n=41) were assessed on the management of a simulated critical event (unstable bradycardia) in the ICU. Participants underwent a group allocation process to either a control group (n=18) or an intervention group (emergency manual provided, n=23). The number of successfully executed treatment and diagnostic interventions completed was evaluated over a ten minute (600 seconds) simulation for each participant. Results The participants using the emergency manual averaged 9.9/12 (83%) interventions, compared to an average of 7.1/12 (59%) interventions (p < 0.01) in the control group. Conclusions The use of an emergency manual was associated with a significant improvement in critical event management by individual novice physicians in a simulated ICU patient (23% average increase). PMID:29600255
Emergency Manuals Improved Novice Physician Performance During Simulated ICU Emergencies.
Kazior, Michael R; Wang, Jacob; Stiegler, Marjorie P; Nguyen, Dung; Rebel, Annette; Isaak, Robert S
2017-01-01
Emergency manuals, which are safety essentials in non-medical high-reliability organizations (e.g., aviation), have recently gained acceptance in critical medical environments. Of the existing emergency manuals in anesthesiology, most are geared towards intraoperative settings. Additionally, most evidence supporting their efficacy focuses on the study of physicians with at least some meaningful experience as a physician. Our aim was to evaluate whether an emergency manual would improve the performance of novice physicians (post-graduate year [PGY] 1 or first year resident) in managing a critical event in the intensive care unit (ICU). PGY1 interns (n=41) were assessed on the management of a simulated critical event (unstable bradycardia) in the ICU. Participants underwent a group allocation process to either a control group (n=18) or an intervention group (emergency manual provided, n=23). The number of successfully executed treatment and diagnostic interventions completed was evaluated over a ten minute (600 seconds) simulation for each participant. The participants using the emergency manual averaged 9.9/12 (83%) interventions, compared to an average of 7.1/12 (59%) interventions (p < 0.01) in the control group. The use of an emergency manual was associated with a significant improvement in critical event management by individual novice physicians in a simulated ICU patient (23% average increase).
Validity of radiographic assessment of the knee joint space using automatic image analysis.
Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki
2016-09-01
The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.
Tippey, Kathryn G; Sivaraj, Elayaraj; Ferris, Thomas K
2017-06-01
This study evaluated the individual and combined effects of voice (vs. manual) input and head-up (vs. head-down) display in a driving and device interaction task. Advances in wearable technology offer new possibilities for in-vehicle interaction but also present new challenges for managing driver attention and regulating device usage in vehicles. This research investigated how driving performance is affected by interface characteristics of devices used for concurrent secondary tasks. A positive impact on driving performance was expected when devices included voice-to-text functionality (reducing demand for visual and manual resources) and a head-up display (HUD) (supporting greater visibility of the driving environment). Driver behavior and performance was compared in a texting-while-driving task set during a driving simulation. The texting task was completed with and without voice-to-text using a smartphone and with voice-to-text using Google Glass's HUD. Driving task performance degraded with the addition of the secondary texting task. However, voice-to-text input supported relatively better performance in both driving and texting tasks compared to using manual entry. HUD functionality further improved driving performance compared to conditions using a smartphone and often was not significantly worse than performance without the texting task. This study suggests that despite the performance costs of texting-while-driving, voice input methods improve performance over manual entry, and head-up displays may further extend those performance benefits. This study can inform designers and potential users of wearable technologies as well as policymakers tasked with regulating the use of these technologies while driving.
Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M
2014-04-01
Clinical trials have shown that hyperthermia, as adjuvant to radiotherapy and/or chemotherapy, improves treatment of patients with locally advanced or recurrent head and neck (H&N) carcinoma. Hyperthermia treatment planning (HTP) guided H&N hyperthermia is being investigated, which requires patient specific 3D patient models derived from Computed Tomography (CT)-images. To decide whether a recently developed automatic-segmentation algorithm can be introduced in the clinic, we compared the impact of manual- and automatic normal-tissue-segmentation variations on HTP quality. CT images of seven patients were segmented automatically and manually by four observers, to study inter-observer and intra-observer geometrical variation. To determine the impact of this variation on HTP quality, HTP was performed using the automatic and manual segmentation of each observer, for each patient. This impact was compared to other sources of patient model uncertainties, i.e. varying gridsizes and dielectric tissue properties. Despite geometrical variations, manual and automatic generated 3D patient models resulted in an equal, i.e. 1%, variation in HTP quality. This variation was minor with respect to the total of other sources of patient model uncertainties, i.e. 11.7%. Automatically generated 3D patient models can be introduced in the clinic for H&N HTP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Doss, Grayson A; Mans, Christoph
2016-06-01
Manual restraint in birds of prey is required for many veterinary and research procedures. To investigate the effects of handling stress on physiologic parameters in raptorial birds, 8 red-tailed hawks ( Buteo jamaicensis ) were manually restrained over a 15-minute period. Respiratory rate (RR), heart rate (HR), and cloacal temperature were monitored over time and recorded at defined intervals during the experiment. The effect of hooding on physiologic variables was also evaluated in a complete crossover design. Both RR and HR decreased significantly during the 15-minute restraint period (HR, -80 ± 101.4 beats/min [bpm], [P < .01]; RR, -17.5 ± 22.6 breaths/min, [P < .05]). Hooded birds had significantly lower HRs and RRs at 15 minutes of restraint (HR: 232.5 ± 26 bpm, [P < .037]; RR: 33.1 ± 6.7 breaths/min, [P < .05]) compared to birds restrained without a hood (HR: 280 ± 74.1 bpm; RR: 51.5 ± 28.8 breaths/min). Cloacal temperature increased significantly in all manually restrained birds (+2.2 ± 0.7°C, [P < .01]), with a comparable increase in hooded and nonhooded birds. In this study of the effects of manual restraint on red-tailed hawks, hooding versus nonhooding amplified the decrease in HR and RR but had no effect on stress-induced hyperthermia.
Preparing Residents Effectively in Emergency Skills Training With a Serious Game
Dankbaar, Mary E.W.; Roozeboom, Maartje Bakhuys; Oprins, Esther A.P. B.; Rutten, Frans; van Merrienboer, Jeroen J.G.; van Saase, Jan L.C.M.; Schuit, Stephanie C.E.
2017-01-01
Introduction Training emergency care skills is critical for patient safety but cost intensive. Serious games have been proposed as an engaging self-directed learning tool for complex skills. The objective of this study was to compare the cognitive skills and motivation of medical residents who only used a course manual as preparation for classroom training on emergency care with residents who used an additional serious game. Methods This was a quasi-experimental study with residents preparing for a rotation in the emergency department. The “reading” group received a course manual before classroom training; the “reading and game” group received this manual plus the game as preparation for the same training. Emergency skills were assessed before training (with residents who agreed to participate in an extra pretraining assessment), using validated competency scales and a global performance scale. We also measured motivation. Results All groups had comparable important characteristics (eg, experience with acute care). Before training, the reading and game group felt motivated to play the game and spent more self-study time (+2.5 hours) than the reading group. Game-playing residents showed higher scores on objectively measured and self-assessed clinical competencies but equal scores on the global performance scale and were equally motivated for training, compared with the reading group. After the 2-week training, no differences between groups existed. Conclusions After preparing training with an additional serious game, residents showed improved clinical competencies, compared with residents who only studied course material. After a 2-week training, this advantage disappeared. Future research should study the retention of game effects in blended designs. PMID:27764018
Preparing Residents Effectively in Emergency Skills Training With a Serious Game.
Dankbaar, Mary E W; Roozeboom, Maartje Bakhuys; Oprins, Esther A P B; Rutten, Frans; van Merrienboer, Jeroen J G; van Saase, Jan L C M; Schuit, Stephanie C E
2017-02-01
Training emergency care skills is critical for patient safety but cost intensive. Serious games have been proposed as an engaging self-directed learning tool for complex skills. The objective of this study was to compare the cognitive skills and motivation of medical residents who only used a course manual as preparation for classroom training on emergency care with residents who used an additional serious game. This was a quasi-experimental study with residents preparing for a rotation in the emergency department. The "reading" group received a course manual before classroom training; the "reading and game" group received this manual plus the game as preparation for the same training. Emergency skills were assessed before training (with residents who agreed to participate in an extra pretraining assessment), using validated competency scales and a global performance scale. We also measured motivation. All groups had comparable important characteristics (eg, experience with acute care). Before training, the reading and game group felt motivated to play the game and spent more self-study time (+2.5 hours) than the reading group. Game-playing residents showed higher scores on objectively measured and self-assessed clinical competencies but equal scores on the global performance scale and were equally motivated for training, compared with the reading group. After the 2-week training, no differences between groups existed. After preparing training with an additional serious game, residents showed improved clinical competencies, compared with residents who only studied course material. After a 2-week training, this advantage disappeared. Future research should study the retention of game effects in blended designs.
Ganji, Yusof; Janabi-Sharifi, Farrokh; Cheema, Asim N
2011-12-01
Despite the recent advances in catheter design and technology, intra-cardiac navigation during electrophysiology procedures remains challenging. Incorporation of imaging along with magnetic or robotic guidance may improve navigation accuracy and procedural safety. In the present study, the in vivo performance of a novel remote controlled Robot Assisted Cardiac Navigation System (RACN) was evaluated in a porcine model. The navigation catheter and target sensor were advanced to the right atrium using fluoroscopic and intra-cardiac echo guidance. The target sensor was positioned at three target locations in the right atrium (RA) and the navigation task was completed by an experienced physician using both manual and RACN guidance. The navigation time, final distance between the catheter tip and target sensor, and variability in final catheter tip position were determined and compared for manual and RACN guided navigation. The experiments were completed in three animals and five measurements recorded for each target location. The mean distance (mm) between catheter tip and target sensor at the end of the navigation task was significantly less using RACN guidance compared with manual navigation (5.02 ± 0.31 vs. 9.66 ± 2.88, p = 0.050 for high RA, 9.19 ± 1.13 vs. 13.0 ± 1.00, p = 0.011 for low RA and 6.77 ± 0.59 vs. 15.66 ± 2.51, p = 0.003 for tricuspid valve annulus). The average time (s) needed to complete the navigation task was significantly longer by RACN guided navigation compared with manual navigation (43.31 ± 18.19 vs. 13.54 ± 1.36, p = 0.047 for high RA, 43.71 ± 11.93 vs. 22.71 ± 3.79, p = 0.043 for low RA and 37.84 ± 3.71 vs. 16.13 ± 4.92, p = 0.003 for tricuspid valve annulus. RACN guided navigation resulted in greater consistency in performance compared with manual navigation as evidenced by lower variability in final distance measurements (0.41 vs. 0.99 mm, p = 0.04). This study demonstrated the safety and feasibility of the RACN system for cardiac navigation. The results demonstrated that RACN performed comparably with manual navigation, with improved precision and consistency for targets located in and near the right atrial chamber. Copyright © 2011 John Wiley & Sons, Ltd.
Patel, Dishant; Bashetty, Kusum; Srirekha, A; Archana, S; Savitha, B; Vijay, R
2016-01-01
The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal. Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third. Chi-squared test was used. The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument. Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used.
NASA Astrophysics Data System (ADS)
Albrecht, F.; Hölbling, D.; Friedl, B.
2017-09-01
Landslide mapping benefits from the ever increasing availability of Earth Observation (EO) data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA) provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR) satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.
Gross, Brooks A.; Walsh, Christine M.; Turakhia, Apurva A.; Booth, Victoria; Mashour, George; Poe, Gina R.
2009-01-01
Manual state scoring of physiological recordings in sleep studies is time-consuming, resulting in a data backlog, research delays and increased personnel costs. We developed MATLAB-based software to automate scoring of sleep/waking states in rats, potentially extendable to other animals, from a variety of recording systems. The software contains two programs, Sleep Scorer and Auto-Scorer, for manual and automated scoring. Auto-Scorer is a logic-based program that displays power spectral densities of an electromyographic signal and σ, δ, and θ frequency bands of an electroencephalographic signal, along with the δ/θ ratio and σ ×θ, for every epoch. The user defines thresholds from the training file state definitions which the Auto-Scorer uses with logic to discriminate the state of every epoch in the file. Auto-Scorer was evaluated by comparing its output to manually scored files from 6 rats under 2 experimental conditions by 3 users. Each user generated a training file, set thresholds, and autoscored the 12 files into 4 states (waking, non-REM, transition-to-REM, and REM sleep) in ¼ the time required to manually score the file. Overall performance comparisons between Auto-Scorer and manual scoring resulted in a mean agreement of 80.24 +/− 7.87%, comparable to the average agreement among 3 manual scorers (83.03 +/− 4.00%). There was no significant difference between user-user and user-Auto-Scorer agreement ratios. These results support the use of our open-source Auto-Scorer, coupled with user review, to rapidly and accurately score sleep/waking states from rat recordings. PMID:19615408
Lehmann, R; Gallert, C; Roddelkopf, T; Junginger, S; Wree, A; Thurow, K
2016-08-01
Cancer diseases are a common problem of the population caused by age and increased harmful environmental influences. Herein, new therapeutic strategies and compound screenings are necessary. The regular 2D cultivation has to be replaced by three dimensional cell culturing (3D) for better simulation of in vivo conditions. The 3D cultivation with alginate matrix is an appropriate method for encapsulate cells to form cancer constructs. The automated manufacturing of alginate beads might be an ultimate method for large-scaled manufacturing constructs similar to cancer tissue. The aim of this study was the integration of full automated systems for the production, cultivation and screening of 3D cell cultures. We compared the automated methods with the regular manual processes. Furthermore, we investigated the influence of antibiotics on these 3D cell culture systems. The alginate beads were formed by automated and manual procedures. The automated steps were processes by the Biomek(®) Cell Workstation (celisca, Rostock, Germany). The proliferation and toxicity were manually and automatically evaluated at day 14 and 35 of cultivation. The results visualized an accumulation and expansion of cell aggregates over the period of incubation. However, the proliferation and toxicity were faintly and partly significantly decreased on day 35 compared to day 14. The comparison of the manual and automated methods displayed similar results. We conclude that the manual production process could be replaced by the automation. Using automation, 3D cell cultures can be produced in industrial scale and improve the drug development and screening to treat serious illnesses like cancer.
Papadimitriou, Lila; Xanthos, Theodoros; Bassiakou, Eleni; Stroumpoulis, Kostantinos; Barouxis, Dimitrios; Iacovidou, Nicolleta
2010-03-01
The present study aims to investigate whether the distribution of the Basic Life Support and Automated External Defibrillation (BLS/AED) manual, 4 weeks prior to the course, has an effect on skill acquisition, theoretical knowledge and skill retention, compared with courses where manuals were not distributed. A total of 303 laypeople were included in the present study. The courses were randomised with sealed envelopes in 12 courses, where manuals were distributed to participants (group A) and in 12 courses, where manuals were not distributed to participants (group B). The participants were formally evaluated at the end of the course, and at 1, 3 and 6 months after each course. The evaluation procedure was the same at all time intervals and consisted of two distinct parts: a written test and a simulated cardiac arrest scenario. No significant difference was observed between the two groups in skill acquisition at the time of initial training. Furthermore, there was no significant difference between the groups in performing BLS/AED skills at 1, 3 and 6 months after initial training. Theoretical knowledge in either group at the specified time intervals did not exhibit any significant difference. Significant deterioration of skills was observed in both groups between initial training and at 1 month after the course, as well as between the first and third month after the course. The present study shows that distribution of BLS/AED manuals 1 month prior to the course has no effect on theoretical knowledge, skill acquisition and skill retention in laypeople. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
PNF and manual therapy treatment results of patients with cervical spine osteoarthritis.
Maicki, Tomasz; Bilski, Jan; Szczygieł, Elżbieta; Trąbka, Rafał
2017-09-22
The aim of this study was to evaluate the effectiveness of PNF and manual therapy methods in the treatment of patients with cervical spine osteoarthritis, especially their efficacy in reducing pain and improving functionality in everyday life. Long-term results were also compared in order to determine which method of treatment is more effective. Eighty randomly selected females aged 45-65 were included in the study. They were randomly divided into two groups of 40 persons. One group received PNF treatment and the other received manual therapy (MAN.T). To evaluate functional capabilities, the Functional Rating Index was used. To evaluate changes in pain, a shortened version of the McGill Questionnaire was used. The PNF group achieved a greater reduction in pain than the MAN.T group. The PNF group showed a greater improvement in performing daily activities such as sleeping, personal care, travelling, work, recreation, lifting, walking and standing as well as decreased intensity and frequency of pain compared to the MAN.T group. The PNF method proved to be more effective in both short (after two weeks) and long (after three months) term.
A hydraulically driven colonoscope.
Coleman, Stuart A; Tapia-Siles, Silvia C; Pakleppa, Markus; Vorstius, Jan B; Keatch, Robert P; Tang, Benjie; Cuschieri, Alfred
2016-10-01
Conventional colonoscopy requires a high degree of operator skill and is often painful for the patient. We present a preliminary feasibility study of an alternative approach where a self-propelled colonoscope is hydraulically driven through the colon. A hydraulic colonoscope which could be controlled manually or automatically was developed and assessed in a test bed modelled on the anatomy of the human colon. A conventional colonoscope was used by an experienced colonoscopist in the same test bed for comparison. Pressures and forces on the colon were measured during the test. The hydraulic colonoscope was able to successfully advance through the test bed in a comparable time to the conventional colonoscope. The hydraulic colonoscope reduces measured loads on artificial mesenteries, but increases intraluminal pressure compared to the colonoscope. Both manual and automatically controlled modes were able to successfully advance the hydraulic colonoscope through the colon. However, the automatic controller mode required lower pressures than manual control, but took longer to reach the caecum. The hydraulic colonoscope appears to be a viable device for further development as forces and pressures observed during use are comparable to those used in current clinical practice.
Sallent, A; Vicente, M; Reverté, M M; Lopez, A; Rodríguez-Baeza, A; Pérez-Domínguez, M; Velez, R
2017-10-01
To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student's t -test and Mann-Whitney U test were used. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article : A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577-583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1. © 2017 Sallent et al.
Area deprivation, individual socioeconomic position and smoking among women in South Korea.
Park, Eun-Ja; Kim, Ho; Kawachi, Ichiro; Kim, Il-Ho; Cho, Sung-Il
2010-10-01
The objective of this study was to examine how area deprivation and individual socioeconomic position affect smoking among women using national survey data. Smoking and individual sociodemographic characteristics were gathered from the Third Korea National Health and Nutrition Examination Survey, 2005. The Carstairs index was derived for each area using the 2005 census data. The data were analysed using multilevel logistic regression models. After adjusting for age and marital status, low education and manual jobs were significantly associated with a higher likelihood of smoking. In addition, the effect of manual jobs on smoking was modified by area deprivation. When individual occupation and area deprivation were examined together, results indicated that women with manual occupation had much greater odds of smoking when they lived in the least-deprived areas (OR, 4.03; CI, 2.00 to 8.14) than did women with manual job who lived in the middle- or most-deprived areas (OR, 2.19; CI, 1.15 to 4.16), compared to the reference group (housewives in the middle- or most-deprived areas). The results of the present study show that among Korean women, manual work is associated with smoking, and the association is strongest among those living in the least-deprived areas. This interaction between manual work and area deprivation resulted in a higher smoking prevalence among women in affluent urban areas.
Wongsritrang, Krongthong; Fueangkamloon, Sumet
2013-09-01
To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.
Computer aided field editing in the DHS context: the Turkey experiment.
Cushing, J; Loaiza, E
1994-01-01
"In this study two types of field editing used during the Turkey Demographic and Health Survey are compared. These two types of editing are computer aided field editing and manual editing. It is known that manual editing by field editors is a tedious job in which errors especially on skip questions can be missed; however, with the aid of computers field editors could quickly find all occasions on which an interviewer incorrectly followed a skip instruction. At the end of the experiment it has been found...that the field editing done with the aid of a notebook computer was consistently better than that done in the standard manual manner." (SUMMARY IN TUR) excerpt
Southerst, Danielle; Yu, Hainan; Randhawa, Kristi; Côté, Pierre; D'Angelo, Kevin; Shearer, Heather M; Wong, Jessica J; Sutton, Deborah; Varatharajan, Sharanya; Goldgrub, Rachel; Dion, Sarah; Cox, Jocelyn; Menta, Roger; Brown, Courtney K; Stern, Paula J; Stupar, Maja; Carroll, Linda J; Taylor-Vaisey, Anne
2015-01-01
Musculoskeletal disorders (MSDs) of the upper and lower extremities are common in the general population and place a significant burden on the health care system. Manual therapy is recommended by clinical practice guidelines for the management of these injuries; however, there is limited evidence to support its effectiveness. The purpose of our review was to investigate the effectiveness of manual therapy in adults or children with MSDs of the upper or lower extremity. Randomized controlled trials (RCTs), cohort studies, and case-control studies evaluating the effectiveness of manual therapy were eligible. We searched MEDLINE, EMBASE, PsycINFO, CINAHL, and the Cochrane Central Register of Controlled Trials from 1990 to 2015. Paired reviewers screened studies for relevance and critically appraised relevant studies using the Scottish Intercollegiate Guidelines Network criteria. Studies with low risk of bias were synthesized following best-evidence synthesis principles. Where available, we computed mean changes between groups, relative risks and 95 % CI. We screened 6047 articles. Seven RCTs were critically appraised and three had low risk of bias. For adults with nonspecific shoulder pain of variable duration, cervicothoracic spinal manipulation and mobilization in addition to usual care may improve self-perceived recovery compared to usual care alone. For adults with subacromial impingement syndrome of variable duration, neck mobilization in addition to a multimodal shoulder program of care provides no added benefit. Finally, for adults with grade I-II ankle sprains of variable duration, lower extremity mobilization in addition to home exercise and advice provides greater short-term improvements in activities and function over home exercise and advice alone. No studies were included that evaluated the effectiveness of manual therapy in children or for the management of other extremity injuries in adults. The current evidence on the effectiveness of manual therapy for MSDs of the upper and lower extremities is limited. The available evidence supports the use of manual therapy for non-specific shoulder pain and ankle sprains, but not for subacromial impingement syndrome in adults. Future research is needed to determine the effectiveness of manual therapy and guide clinical practice. CRD42014009899.
Leelarungrayub, Jirakrit; Eungpinichpong, Wichai; Klaphajone, Jakkrit; Prasannarong, Mujalin; Boontha, Kritsana
2016-04-01
The aim of this study was to evaluate the influence of manual percussion during three different positions of postural drainage (PD) on lung volumes and metabolic status. Twenty six healthy volunteers (13 women and 13 men), with a mean age of 20.15 ± 1.17 years, participated. They were randomized into three standard positions of PD (upper, middle, or lower lobes) and given manual percussion at a frequency of 240 times per minute for 5 min. Lung volumes, including tidal volume (TV), inspiratory reserve volume (IRV), expiratory reserve volume (ERV) and vital capacity (VC); and metabolic status, such as oxygen consumption (VO2), carbon dioxide (VCO2), respiratory rate (RR), and minute ventilation (VE) were evaluated. The lung volumes showed no statistical difference in VC or IRV from percussion during PD in all positions, except for the lower lobe, where increased TV and decreased ERV were found when compared to PD alone. Furthermore, percussion during PD of the upper and middle lobes did not affect RR or VE, when compared to PD alone. In addition, percussion during PD of the middle and lower lobes increased VO2 and VCO2 significantly, when compared to PD alone, but it did not influence PD of the upper lobe. This study indicated that up to 5 min of manual percussion on PD of the upper and middle lobes is safe mostly for lung volumes, RR, and VE, but it should be given with care in PD conditions of the lower lobe. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kaya, E; Elbay, M; Yiğit, D
2017-06-01
The Self-Adjusting File (SAF) system has been recommended for use in permanent teeth since it offers more conservative and effective root-canal preparation when compared to traditional rotary systems. However, no study had evaluated the usage of SAF in primary teeth. The aim of this study was to evaluate and compare the use of SAF, K file (manual instrumentation) and Profile (traditional rotary instrumentation) systems for primary-tooth root-canal preparation in terms of instrumentation time and amounts of dentin removed using micro-computed tomography (μCT) technology. Study Design: The study was conducted with 60 human primary mandibular second molar teeth divided into 3 groups according to instrumentation technique: Group I: SAF (n=20); Group II: K file (n=20); Group III; Profile (n=20). Teeth were embedded in acrylic blocks and scanned with a μCT scanner prior to instrumentation. All distal root canals were prepared up to size 30 for K file,.04/30 for Profile and 2 mm thickness, size 25 for SAF; instrumentation time was recorded for each tooth, and a second μCT scan was performed after instrumentation was complete. Amounts of dentin removed were measured using the three-dimensional images by calculating the difference in root-canal volume before and after preparation. Data was statistically analysed using the Kolmogorov-Smirnov and Kruskal-Wallis tests. Manual instrumentation (K file) resulted in significantly more dentin removal when compared to rotary instrumentation (Profile and SAF), while the SAF system generated significantly less dentin removal than both manual instrumentation (K file) and traditional rotary instrumentation (Profile) (p<.05). Instrumentation time was significantly greater with manual instrumentation when compared to rotary instrumentation (p<.05), whereas instrumentation time did not differ significantly between the Profile and SAF systems. Within the experimental conditions of the present study, the SAF seems as a useful system for root-canal instrumentation in primary molars because it removed less dentin than other systems, which is especially important for the relatively thin-walled canals of primary teeth, and because it involves less clinical time, which is particularly important in the treatment of paediatric patients.
Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique?
Citak, Mustafa; Suero, Eduardo M; Citak, Musa; Dunbar, Nicholas J; Branch, Sharon H; Conditt, Michael A; Banks, Scott A; Pearle, Andrew D
2013-08-01
Robotic-assisted unicompartmental knee arthroplasty (UKA) with rigid bone fixation "can significantly improve implant placement and leg alignment. The aim of this cadaveric study was to determine whether the use of robotic systems with dynamic bone tracking would provide more accurate UKA implant positioning compared to the conventional manual technique. Three-dimensional CT-based preoperative plans were created to determine the desired position and orientation for the tibial and femoral components. For each pair of cadaver knees, UKA was performed using traditional instrumentation on the left side and using a haptic robotic system on the right side. Postoperative CT scans were obtained and 3D-to-3D iterative closest point registration was performed. Implant position and orientation were compared to the preoperative plan. Surgical RMS errors for femoral component placement were within 1.9 mm and 3.7° in all directions of the planned implant position for the robotic group, while RMS errors for the manual group were within 5.4mm and 10.2°. Average RMS errors for tibial component placement were within 1.4mm and 5.0° in all directions for the robotic group; while, for the manual group, RMS errors were within 5.7 mm and 19.2°. UKA was more precise using a semiactive robotic system with dynamic bone tracking technology compared to the manual technique. Copyright © 2012 Elsevier B.V. All rights reserved.
Teżyk, Michał; Jakubowska, Emilia; Milczewska, Kasylda; Milanowski, Bartłomiej; Voelkel, Adam; Lulek, Janina
2017-06-01
The aim of this article is to compare the gravitational powder blend loading method to the tablet press and manual loading in terms of their influence on tablets' critical quality attributes (CQA). The results of the study can be of practical relevance to the pharmaceutical industry in the area of direct compression of low-dose formulations, which could be prone to content uniformity (CU) issues. In the preliminary study, particle size distribution (PSD) and surface energy of raw materials were determined using laser diffraction method and inverse gas chromatography, respectively. For trials purpose, a formulation containing two pharmaceutical ingredients (APIs) was used. Tablet samples were collected during the compression progress to analyze their CQAs, namely assay and CU. Results obtained during trials indicate that tested direct compression powder blend is sensitive to applied powder handling method. Mild increase in both APIs content was observed during manual scooping. Gravitational approach (based on discharge into the drum) resulted in a decrease in CU, which is connected to a more pronounced assay increase at the end of tableting than in the case of manual loading. The correct design of blend transfer over single unit processes is an important issue and should be investigated during the development phase since it may influence the final product CQAs. The manual scooping method, although simplistic, can be a temporary solution to improve the results of API's content and uniformity when compared to industrial gravitational transfer.
Roy, Sanjoy; Yoo, Andrew; Yadalam, Sashi; Fegelman, Elliott J; Kalsekar, Iftekhar; Johnston, Stephen S
2017-04-01
To compare economic and clinical outcomes between patients undergoing laparoscopic Roux-en-Y gastric bypass (LRY) or laparoscopic sleeve gastrectomy (LSG) with use of powered vs manual endoscopic surgical staplers. Patients (aged ≥21 years) who underwent LRY or LSG during a hospital admission (January 1, 2012-September 30, 2015) were identified from the Premier Perspective Hospital Database. Use of powered vs manual staplers was identified from hospital administrative billing records. Multivariable analyses were used to compare the following outcomes between the powered and manual stapler groups, adjusting for patient and hospital characteristics and hospital-level clustering: hospital length of stay (LOS), total hospital costs, medical/surgical supply costs, room and board costs, operating room costs, operating room time, discharge status, bleeding/transfusion during the hospital admission, and 30, 60, and 90-day all-cause readmissions. The powered and manual stapler groups comprised 9,851 patients (mean age = 44.6 years; 79.3% female) and 21,558 patients (mean age = 45.0 years; 78.0% female), respectively. In the multivariable analyses, adjusted mean hospital LOS was 2.1 days for both the powered and manual stapler groups (p = .981). Adjusted mean total hospital costs ($12,415 vs $13,547, p = .003), adjusted mean supply costs ($4,629 vs $5,217, p = .011), and adjusted mean operating room costs ($4,126 vs $4,413, p = .009) were significantly lower in the powered vs manual stapler group. The adjusted rate of bleeding and/or transfusion during the hospital admission (2.46% vs 3.22%, p = .025) was significantly lower in the powered vs manual stapler group. The adjusted rates of 30, 60, and 90-day all-cause readmissions were similar between the groups (all p > .05). Sub-analysis by manufacturer showed similar results. This observational study cannot establish causal linkages. In this analysis of patients who underwent LRY or LSG, the use of powered staplers was associated with better economic outcomes, and a lower rate of bleeding/transfusion vs manual staplers in the real-world setting.
NASA Astrophysics Data System (ADS)
Fritzsche, Klaus H.; Giesel, Frederik L.; Heimann, Tobias; Thomann, Philipp A.; Hahn, Horst K.; Pantel, Johannes; Schröder, Johannes; Essig, Marco; Meinzer, Hans-Peter
2008-03-01
Objective quantification of disease specific neurodegenerative changes can facilitate diagnosis and therapeutic monitoring in several neuropsychiatric disorders. Reproducibility and easy-to-perform assessment are essential to ensure applicability in clinical environments. Aim of this comparative study is the evaluation of a fully automated approach that assesses atrophic changes in Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI). 21 healthy volunteers (mean age 66.2), 21 patients with MCI (66.6), and 10 patients with AD (65.1) were enrolled. Subjects underwent extensive neuropsychological testing and MRI was conducted on a 1.5 Tesla clinical scanner. Atrophic changes were measured automatically by a series of image processing steps including state of the art brain mapping techniques. Results were compared with two reference approaches: a manual segmentation of the hippocampal formation and a semi-automated estimation of temporal horn volume, which is based upon interactive selection of two to six landmarks in the ventricular system. All approaches separated controls and AD patients significantly (10 -5 < p < 10 -4) and showed a slight but not significant increase of neurodegeneration for subjects with MCI compared to volunteers. The automated approach correlated significantly with the manual (r = -0.65, p < 10 -6) and semi automated (r = -0.83, p < 10 -13) measurements. It proved high accuracy and at the same time maximized observer independency, time reduction and thus usefulness for clinical routine.
Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M
2005-10-01
To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. ProTaper instruments created more regular canal diameters.
Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C
2017-08-01
The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.
Cayi, Ruijun; Li, Mei; Xiong, Gang; Cai, Kaican; Wang, Wujun
2012-06-01
To compare the complications associated with mechanical and manual cervical esophagogastric anastomosis following esophagectomy for esophageal cancer. From September, 2004 to June, 2007, 227 patients with middle and upper thoracic esophageal cancer underwent cervical esophagogastric anastomosis after esophagectomy. The patients were randomized into two groups and cervical esophagogastric anastomosis was performed using a stapler (n=102) or manually (n=125). The incidence of postoperative complications and operative time were compared between the two groups. In manual anastomosis group, anastomotic leak and anastomotic stricture occurred in 14.4% (18/125) and 8.8.% (11/125) of the patients, significantly higher than the incidences of 2.9% (3/102) and 3.9% (4/102) in the mechanical anastomosis group (P<0.01). Manual anastomosis required a significantly longer operative time than mechanical anastomosis (52∓12 vs 25∓5 min, P<0.01). The use of circular mechanical stapler in cervical esophagogastric anastomosis is associated with a lower rate of anastomotic leak and a shorter operative time, and is easy to learn and standardize to reduce the complications of the anastomosis.
Adams, Derk; Schreuder, Astrid B; Salottolo, Kristin; Settell, April; Goss, J Richard
2011-07-01
There are significant changes in the abbreviated injury scale (AIS) 2005 system, which make it impractical to compare patients coded in AIS version 98 with patients coded in AIS version 2005. Harborview Medical Center created a computer algorithm "Harborview AIS Mapping Program (HAMP)" to automatically convert AIS 2005 to AIS 98 injury codes. The mapping was validated using 6 months of double-coded patient injury records from a Level I Trauma Center. HAMP was used to determine how closely individual AIS and injury severity scores (ISS) were converted from AIS 2005 to AIS 98 versions. The kappa statistic was used to measure the agreement between manually determined codes and HAMP-derived codes. Seven hundred forty-nine patient records were used for validation. For the conversion of AIS codes, the measure of agreement between HAMP and manually determined codes was [kappa] = 0.84 (95% confidence interval, 0.82-0.86). The algorithm errors were smaller in magnitude than the manually determined coding errors. For the conversion of ISS, the agreement between HAMP versus manually determined ISS was [kappa] = 0.81 (95% confidence interval, 0.78-0.84). The HAMP algorithm successfully converted injuries coded in AIS 2005 to AIS 98. This algorithm will be useful when comparing trauma patient clinical data across populations coded in different versions, especially for longitudinal studies.
Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee
2016-09-01
The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.
Manual for the Comparative Politics Laboratory: Conditions for Effective Democracy.
ERIC Educational Resources Information Center
Fogelman, Edwin; Zingale, Nancy
This manual introduces undergraduate students in political science to major types of data and methods for cross-national quantitative analysis. The manual's topic, Conditions for Effective Democracy, was chosen because it incorporates several different kinds of data and illustrates various methodological problems. The data are cross-sectional…
Trautz, Florian; Dreßler, Jan; Stassart, Ruth; Müller, Wolf; Ondruschka, Benjamin
2018-01-03
Immunohistochemistry (IHC) has become an integral part in forensic histopathology over the last decades. However, the underlying methods for IHC vary greatly depending on the institution, creating a lack of comparability. The aim of this study was to assess the optimal approach for different technical aspects of IHC, in order to improve and standardize this procedure. Therefore, qualitative results from manual and automatic IHC staining of brain samples were compared, as well as potential differences in suitability of common IHC glass slides. Further, possibilities of image digitalization and connected issues were investigated. In our study, automatic staining showed more consistent staining results, compared to manual staining procedures. Digitalization and digital post-processing facilitated direct analysis and analysis for reproducibility considerably. No differences were found for different commercially available microscopic glass slides regarding suitability of IHC brain researches, but a certain rate of tissue loss should be expected during the staining process.
A pilot study of myofascial release therapy compared to Swedish massage in Fibromyalgia
Liptan, Ginevra; Mist, Scott; Wright, Cheryl; Arzt, Anna; Jones, Kim Dupree
2017-01-01
Summary Fibromyalgia (FM) is characterized by widespread muscle pain and soft tissue tenderness. However, a lack of definitive muscle pathology has made FM both a diagnostic and a treatment puzzle. Much of the evidence for pathology in FM lies in the central nervous system – in particular abnormal amplification of pain signals in the spinal cord – a manifestation of central sensitization. An emerging body of evidence posits that peripheral pain generated from the muscles and fascia may trigger and maintain central sensitization in FM. Since FM patients so frequently seek manual therapy to relieve muscle symptoms, the present study compared two different manual therapy techniques in a parallel study of women with FM. Eight subjects received myofascial release (MFR) while four subjects received Swedish massage, 90 min weekly for four weeks. Overall symptom burden and physical function were assessed by the Fibromyalgia Impact Questionnaire Revised (FIQ-R). A unique challenge for the manual therapist in treating conditions involving central sensitization is to determine if localized pain reduction can be achieved with targeted therapy in the context of ongoing widespread pain. Localized pain improvement was measured by a novel questionnaire developed for this study, the modified Nordic Musculoskeletal Questionnaire (NMQ). Between-group differences in FIQ-R did not reach statistical significance, but the total change scores on FIQ-R for the MFR group (mean = 10.14, SD = 16.2) trended in the hypothesized and positive direction compared to the Swedish massage group (mean = 0.33, SD = 4.93) yielding a positive Aikin separation test. Although overall modified NMQ scores improved in both groups there were no consistent focal areas of improvement for the Swedish massage group. In contrast, the MFR group reported consistent pain reductions in the neck and upper back regions on the NMQ. These data support the need for larger randomized controlled trials of MFR versus other massage techniques and support the assessment of localized pain reduction in future manual therapy studies in FM. PMID:23768283
Rios Velazquez, Emmanuel; Meier, Raphael; Dunn, William D; Alexander, Brian; Wiest, Roland; Bauer, Stefan; Gutman, David A; Reyes, Mauricio; Aerts, Hugo J W L
2015-11-18
Reproducible definition and quantification of imaging biomarkers is essential. We evaluated a fully automatic MR-based segmentation method by comparing it to manually defined sub-volumes by experienced radiologists in the TCGA-GBM dataset, in terms of sub-volume prognosis and association with VASARI features. MRI sets of 109 GBM patients were downloaded from the Cancer Imaging archive. GBM sub-compartments were defined manually and automatically using the Brain Tumor Image Analysis (BraTumIA). Spearman's correlation was used to evaluate the agreement with VASARI features. Prognostic significance was assessed using the C-index. Auto-segmented sub-volumes showed moderate to high agreement with manually delineated volumes (range (r): 0.4 - 0.86). Also, the auto and manual volumes showed similar correlation with VASARI features (auto r = 0.35, 0.43 and 0.36; manual r = 0.17, 0.67, 0.41, for contrast-enhancing, necrosis and edema, respectively). The auto-segmented contrast-enhancing volume and post-contrast abnormal volume showed the highest AUC (0.66, CI: 0.55-0.77 and 0.65, CI: 0.54-0.76), comparable to manually defined volumes (0.64, CI: 0.53-0.75 and 0.63, CI: 0.52-0.74, respectively). BraTumIA and manual tumor sub-compartments showed comparable performance in terms of prognosis and correlation with VASARI features. This method can enable more reproducible definition and quantification of imaging based biomarkers and has potential in high-throughput medical imaging research.
Murray, Andrea K; Feng, Kaiyan; Moore, Tonia L; Allen, Phillip D; Taylor, Christopher J; Herrick, Ariane L
2011-08-01
Nailfold capillaroscopy is well established in screening patients with Raynaud's phenomenon for underlying SSc-spectrum disorders, by identifying abnormal capillaries. Our aim was to compare semi-automatic feature measurement from newly developed software with manual measurements, and determine the degree to which semi-automated data allows disease group classification. Images from 46 healthy controls, 21 patients with PRP and 49 with SSc were preprocessed, and semi-automated measurements of intercapillary distance and capillary width, tortuosity, and derangement were performed. These were compared with manual measurements. Features were used to classify images into the three subject groups. Comparison of automatic and manual measures for distance, width, tortuosity, and derangement had correlations of r=0.583, 0.624, 0.495 (p<0.001), and 0.195 (p=0.040). For automatic measures, correlations were found between width and intercapillary distance, r=0.374, and width and tortuosity, r=0.573 (p<0.001). Significant differences between subject groups were found for all features (p<0.002). Overall, 75% of images correctly matched clinical classification using semi-automated features, compared with 71% for manual measurements. Semi-automatic and manual measurements of distance, width, and tortuosity showed moderate (but statistically significant) correlations. Correlation for derangement was weaker. Semi-automatic measurements are faster than manual measurements. Semi-automatic parameters identify differences between groups, and are as good as manual measurements for between-group classification. © 2011 John Wiley & Sons Ltd.
van 't Klooster, Ronald; de Koning, Patrick J H; Dehnavi, Reza Alizadeh; Tamsma, Jouke T; de Roos, Albert; Reiber, Johan H C; van der Geest, Rob J
2012-01-01
To develop and validate an automated segmentation technique for the detection of the lumen and outer wall boundaries in MR vessel wall studies of the common carotid artery. A new segmentation method was developed using a three-dimensional (3D) deformable vessel model requiring only one single user interaction by combining 3D MR angiography (MRA) and 2D vessel wall images. This vessel model is a 3D cylindrical Non-Uniform Rational B-Spline (NURBS) surface which can be deformed to fit the underlying image data. Image data of 45 subjects was used to validate the method by comparing manual and automatic segmentations. Vessel wall thickness and volume measurements obtained by both methods were compared. Substantial agreement was observed between manual and automatic segmentation; over 85% of the vessel wall contours were segmented successfully. The interclass correlation was 0.690 for the vessel wall thickness and 0.793 for the vessel wall volume. Compared with manual image analysis, the automated method demonstrated improved interobserver agreement and inter-scan reproducibility. Additionally, the proposed automated image analysis approach was substantially faster. This new automated method can reduce analysis time and enhance reproducibility of the quantification of vessel wall dimensions in clinical studies. Copyright © 2011 Wiley Periodicals, Inc.
LI, GUO-CAI; XU, YONG; ZHANG, YU-CHUN; ZHANG, FANG-CHENG; WANG, QI; MA, QING-JIU
2014-01-01
Surgery for digestive tract disease predominantly consists of reconstruction and anastomosis. Due to the difficult location, anastomosis is extremely challenging and the risk of complication increases accordingly. Traditional manual anastomosis and the application of a stapling device are insufficient. Therefore, the aim of this study was to investigate the feasibility and safety of a novel manual method in a difficult anastomotic location, consisting of a single-layer continuous suture in the posterior wall. In total, 15 beagle dogs were included in the study; eight underwent surgery with the novel manual method for reconstruction and anastomosis of the digestive tract, while seven underwent surgery with the stapler device as a control. The subsequent postoperative complications were observed and, three months later, the anastomotic ports were excised, and the pathological formation and morphological changes were evaluated. No statistically significant differences were identified between the total (50.0 vs. 57.1%; P=0.782) and anastomotic (0.0 vs. 28.6%; P=0.200) complication rates in the manual suture and staple suture groups, respectively. Compared with the control group, the operative expenditure was lower in the manual group (1726.7±33.5 vs. 2135.7±43.1 renminbi; P=0.001), the diameter of the anastomotic port was larger in the manual group (3.04±0.07 vs. 2.24±0.25 cm; P=0.004) and the thickness of the anastomotic port (in cm) was thinner in the manual group (2.94±0.06 vs. 5.07±0.85; P=0.002). Furthermore, the pathological formation of the anastomositic port in the manual group was improved. The results of the current study suggest single-layer continuous suture of the posterior wall in anastomosis of the digestive tract to be a novel method with feasibility and safety, particularly in difficult anastomotic locations. PMID:25202369
Li, Guo-Cai; Xu, Yong; Zhang, Yu-Chun; Zhang, Fang-Cheng; Wang, Qi; Ma, Qing-Jiu
2014-10-01
Surgery for digestive tract disease predominantly consists of reconstruction and anastomosis. Due to the difficult location, anastomosis is extremely challenging and the risk of complication increases accordingly. Traditional manual anastomosis and the application of a stapling device are insufficient. Therefore, the aim of this study was to investigate the feasibility and safety of a novel manual method in a difficult anastomotic location, consisting of a single-layer continuous suture in the posterior wall. In total, 15 beagle dogs were included in the study; eight underwent surgery with the novel manual method for reconstruction and anastomosis of the digestive tract, while seven underwent surgery with the stapler device as a control. The subsequent postoperative complications were observed and, three months later, the anastomotic ports were excised, and the pathological formation and morphological changes were evaluated. No statistically significant differences were identified between the total (50.0 vs. 57.1%; P=0.782) and anastomotic (0.0 vs. 28.6%; P=0.200) complication rates in the manual suture and staple suture groups, respectively. Compared with the control group, the operative expenditure was lower in the manual group (1726.7±33.5 vs. 2135.7±43.1 renminbi; P=0.001), the diameter of the anastomotic port was larger in the manual group (3.04±0.07 vs. 2.24±0.25 cm; P=0.004) and the thickness of the anastomotic port (in cm) was thinner in the manual group (2.94±0.06 vs. 5.07±0.85; P=0.002). Furthermore, the pathological formation of the anastomositic port in the manual group was improved. The results of the current study suggest single-layer continuous suture of the posterior wall in anastomosis of the digestive tract to be a novel method with feasibility and safety, particularly in difficult anastomotic locations.
Content and bibliometric analyses of the Journal of Manual & Manipulative Therapy
Simon, Corey B; Coronado, Rogelio A; Wurtzel, Wendy A; Riddle, Daniel L; George, Steven Z
2014-01-01
Background: Article characteristics and trends have been elucidated for other physical therapy-focused journals using content and bibliometric analysis. These findings are important for assessing the current state of a journal and for guiding future publication of research. To date, these analyses have not been performed for the Journal of Manual & Manipulative Therapy (JMMT). Objective: To describe content and trends for articles published in JMMT over a 20-year period (1993–2012). Methods: Journal articles were coded using previously-established domains (article type, participant type, research design, study purpose, and clinical condition). Total publications and proportion of publications based on domain were described. Articles specific to manual therapy intervention were examined and compared to data from other physical therapy-focused journals. Impact by citation and author was examined using bibliometric software. Results: Journal of Manual & Manipulative Therapy was found to have a recent acceleration in the number of articles published annually. Over time, topical reviews have decreased in favor of research reports. However, rigorous study designs have represented only a small portion of total journal content, and case reports have maintained a consistent publication presence. Manual therapy intervention articles in JMMT are predominantly case designs, however are similar in characteristics to manual therapy intervention articles published in other physical therapy-focused journals. For JMMT articles overall and manual therapy intervention articles across journals, young to middle-aged symptomatic adults with low back and/or neck pain were the most common study participants. Discussion: Increases in the number of papers and a move toward research reports were observed in JMMT over the 20-year period. Considerations for the future were outlined, including the publication of articles with more rigorous research designs. Manual therapy research for adolescents and older adults and for upper and lower extremity conditions should also be considered as priorities for the future. PMID:25395826
Dinov, Borislav; Schönbauer, Robert; Wojdyla-Hordynska, Agnieska; Braunschweig, Frieder; Richter, Sergio; Altmann, David; Sommer, Philipp; Gaspar, Thomas; Bollmann, Andreas; Wetzel, Ulrike; Rolf, Sascha; Piorkowski, Christopher; Hindricks, Gerhard; Arya, Arash
2012-05-01
Remote magnetic navigation (RMN) aims to reduce some inherent limitations of manual radiofrequency (RF) ablation. However, data comparing the effectiveness of both methods are scarce. This study evaluated the acute and long-term success of RMN guided versus manual RF ablation in patients with ischemic sustained ventricular tachycardia (sVT). One hundred two consecutive patients (age 68 ± 10 years, LVEF 32 ± 12%, 88 men) with ischemic sVT were ablated with RMN (Stereotaxis; 49%) or manually (51%) using substrate and/or activation mapping (Carto) and open-irrigated-tip catheters. All received implantable defibrillators or loop recorders. Acute success was defined as noninducibility of any sVT at the end of the ablation procedure and long-term success as freedom from VT upon follow-up. There was no difference in the baseline characteristics between the groups. Three patients died in hospital. Acute success rate was similar for RMN and manual ablation (82% vs 71%, P = 0.246). RMN was associated with significantly shorter fluoroscopy time (13 ± 12 minutes vs 32 ± 17 minutes, P = 0.0001) and RF time (2337.59 ± 1248.22 seconds vs 1589.95 ± 1047.42 seconds, P = 0.049), although total procedure time was similar (157 ± 40 minutes vs 148 ± 50 minutes, P = 0.42). There was a nonsignificant trend toward better long-term success in RMN group: after a median of 13 (range 1-34) months, 63% in the RMN and 53% in the manual ablation group were free from VT recurrence (P = 0.206). RMN guided RF ablation of ischemic sustained VT is equally efficient compared with manual ablation in terms of acute and long-term success rate. These results are achieved with a significantly reduced fluoroscopy time and shorter RF time. © 2012 Wiley Periodicals, Inc.
McCartney, Elspeth; Boyle, James; Bannatyne, Susan; Jessiman, Emma; Campbell, Cathy; Kelsey, Cherry; Smith, Jennifer; O'Hare, Anne
2004-01-01
The construction of therapy protocols for a large-scale randomized controlled trial comparing speech and language therapists and assistants, and group and individual therapy approaches for children aged 6-11 in mainstream schools is outlined. The aim was to outline the decision-making processes that led to the construction of the research therapy manual, and to give a preliminary report on compliance with the manual. A search of the research and professional literature and of published therapy materials was conducted to locate usable examples of effective language therapy for primary school children. Results were collated into a manual of therapy principles and activities to structure research intervention. The use of the manual with children (n=30) receiving individual or group direct therapy from a speech and language therapist in the first phase of intervention was audited. Very few high-level research studies were found, but the professional literature gave added information. Therapies for comprehension monitoring, vocabulary development, later grammar and narrative were adapted for the research intervention, and procedures compiled into a manual to guide research speech and language therapists and assistants. The audit of direct therapy suggested that the manual was useable, providing a suitable range of activities and materials for therapy intervention. Its use helped to record the therapy offered to research children, and formed a sound basis for discussion amongst speech and language therapists and between speech and language therapist/assistant pairs. The construction and use of a therapy manual allowed the provision of replicable therapy within the research project whilst maintaining flexibility.
Wind Tunnel Force Balance Calibration Study - Interim Results
NASA Technical Reports Server (NTRS)
Rhew, Ray D.
2012-01-01
Wind tunnel force balance calibration is preformed utilizing a variety of different methods and does not have a direct traceable standard such as standards used for most calibration practices (weights, and voltmeters). These different calibration methods and practices include, but are not limited to, the loading schedule, the load application hardware, manual and automatic systems, re-leveling and non-re-leveling. A study of the balance calibration techniques used by NASA was undertaken to develop metrics for reviewing and comparing results using sample calibrations. The study also includes balances of different designs, single and multi-piece. The calibration systems include, the manual, and the automatic that are provided by NASA and its vendors. The results to date will be presented along with the techniques for comparing the results. In addition, future planned calibrations and investigations based on the results will be provided.
Arnfred, Sidse M; Aharoni, Ruth; Hvenegaard, Morten; Poulsen, Stig; Bach, Bo; Arendt, Mikkel; Rosenberg, Nicole K; Reinholt, Nina
2017-01-23
Transdiagnostic Cognitive Behavior Therapy (TCBT) manuals delivered in individual format have been reported to be just as effective as traditional diagnosis specific CBT manuals. We have translated and modified the "The Unified Protocol for Transdiagnostic Treatment of Emotional Disorders" (UP-CBT) for group delivery in Mental Health Service (MHS), and shown effects comparable to traditional CBT in a naturalistic study. As the use of one manual instead of several diagnosis-specific manuals could simplify logistics, reduce waiting time, and increase therapist expertise compared to diagnosis specific CBT, we aim to test the relative efficacy of group UP-CBT and diagnosis specific group CBT. The study is a partially blinded, pragmatic, non-inferiority, parallel, multi-center randomized controlled trial (RCT) of UP-CBT vs diagnosis specific CBT for Unipolar Depression, Social Anxiety Disorder and Agoraphobia/Panic Disorder. In total, 248 patients are recruited from three regional MHS centers across Denmark and included in two intervention arms. The primary outcome is patient-ratings of well-being (WHO Well-being Index, WHO-5), secondary outcomes include level of depressive and anxious symptoms, personality variables, emotion regulation, reflective functioning, and social adjustment. Assessments are conducted before and after therapy and at 6 months follow-up. Weekly patient-rated outcomes and group evaluations are collected for every session. Outcome assessors, blind to treatment allocation, will perform the observer-based symptom ratings, and fidelity assessors will monitor manual adherence. The current study will be the first RCT investigating the dissemination of the UP in a MHS setting, the UP delivered in groups, and with depressive patients included. Hence the results are expected to add substantially to the evidence base for rational group psychotherapy in MHS. The planned moderator and mediator analyses could spur new hypotheses about mechanisms of change in psychotherapy and the association between patient characteristics and treatment effect. Clinicaltrials.gov NCT02954731 . Registered 25 October 2016.
Maret, Eva; Brudin, Lars; Lindstrom, Lena; Nylander, Eva; Ohlsson, Jan L; Engvall, Jan E
2008-01-01
Background Left ventricular size and function are important prognostic factors in heart disease. Their measurement is the most frequent reason for sending patients to the echo lab. These measurements have important implications for therapy but are sensitive to the skill of the operator. Earlier automated echo-based methods have not become widely used. The aim of our study was to evaluate an automatic echocardiographic method (with manual correction if needed) for determining left ventricular ejection fraction (LVEF) based on an active appearance model of the left ventricle (syngo®AutoEF, Siemens Medical Solutions). Comparisons were made with manual planimetry (manual Simpson), visual assessment and automatically determined LVEF from quantitative myocardial gated single photon emission computed tomography (SPECT). Methods 60 consecutive patients referred for myocardial perfusion imaging (MPI) were included in the study. Two-dimensional echocardiography was performed within one hour of MPI at rest. Image quality did not constitute an exclusion criterion. Analysis was performed by five experienced observers and by two novices. Results LVEF (%), end-diastolic and end-systolic volume/BSA (ml/m2) were for uncorrected AutoEF 54 ± 10, 51 ± 16, 24 ± 13, for corrected AutoEF 53 ± 10, 53 ± 18, 26 ± 14, for manual Simpson 51 ± 11, 56 ± 20, 28 ± 15, and for MPI 52 ± 12, 67 ± 26, 35 ± 23. The required time for analysis was significantly different for all four echocardiographic methods and was for uncorrected AutoEF 79 ± 5 s, for corrected AutoEF 159 ± 46 s, for manual Simpson 177 ± 66 s, and for visual assessment 33 ± 14 s. Compared with the expert manual Simpson, limits of agreement for novice corrected AutoEF was lower than for novice manual Simpson (0.8 ± 10.5 vs. -3.2 ± 11.4 LVEF percentage points). Calculated for experts and with LVEF (%) categorized into < 30, 30–44, 45–54 and ≥ 55, kappa measure of agreement was moderate (0.44–0.53) for all method comparisons (uncorrected AutoEF not evaluated). Conclusion Corrected AutoEF reduces the variation in measurements compared with manual planimetry, without increasing the time required. The method seems especially suited for unexperienced readers. PMID:19014461
Nelwan, Erni J; Indrasanti, Evi; Sinto, Robert; Nurchaida, Farida; Sosrosumihardjo, Rustadi
2016-01-01
to evaluate the performance of Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patients. a comparison study to evaluate Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patient was done. Categorical agreement between manual disc diffusion and Vitek2 machine was calculated using predefined criteria. Time to susceptibility result for automated and manual methods were measured. there were 137 Candida isolates comprising eight Candida species with C.albicans and C. glabrata as the first (56.2%) and second (15.3%) most common species, respectively. For fluconazole drug, among the C. albicans, 2.6% was found resistant on manual disc diffusion methods and no resistant was determined by Vitek2 machine; whereas 100% C. krusei was identified as resistant on both methods. Resistant patterns for C. glabrata to fluconazole, voriconazole and amphotericin B were 52.4%, 23.8%, 23.8% vs. 9.5%, 9.5%, 4.8% respectively between manual diffusion disc methods and Vitek2 machine. Time to susceptibility result for automated methods compared to Vitex2 machine was shorter for all Candida species. there is a good categorical agreement between manual disc diffusion and Vitek2 machine, except for C. glabrata for measuring the antifungal resistant. Time to susceptibility result for automated methods is shorter for all Candida species.
Jansen, Mariette J; Viechtbauer, Wolfgang; Lenssen, Antoine F; Hendriks, Erik J M; de Bie, Rob A
2011-01-01
What are the effects of strength training alone, exercise therapy alone, and exercise with additional passive manual mobilisation on pain and function in people with knee osteoarthritis compared to control? What are the effects of these interventions relative to each other? A meta-analysis of randomised controlled trials. Adults with osteoarthritis of the knee. INTERVENTION TYPES: Strength training alone, exercise therapy alone (combination of strength training with active range of motion exercises and aerobic activity), or exercise with additional passive manual mobilisation, versus any non-exercise control. Comparisons between the three interventions were also sought. The primary outcome measures were pain and physical function. 12 trials compared one of the interventions against control. The effect size on pain was 0.38 (95% CI 0.23 to 0.54) for strength training, 0.34 (95% CI 0.19 to 0.49) for exercise, and 0.69 (95% CI 0.42 to 0.96) for exercise plus manual mobilisation. Each intervention also improved physical function significantly. No randomised comparisons of the three interventions were identified. However, meta-regression indicated that exercise plus manual mobilisations improved pain significantly more than exercise alone (p = 0.03). The remaining comparisons between the three interventions for pain and physical function were not significant. Exercise therapy plus manual mobilisation showed a moderate effect size on pain compared to the small effect sizes for strength training or exercise therapy alone. To achieve better pain relief in patients with knee osteoarthritis physiotherapists or manual therapists might consider adding manual mobilisation to optimise supervised active exercise programs. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.
Popević, Martin B; Janković, Srđan M; Borjanović, Srđan S; Jovičić, Slavica R; Tenjović, Lazar R; Milovanović, Aleksandar P S; Bulat, Petar
2014-03-01
A frequently encountered exposure profile for hand-arm vibration in contemporary occupational setting comprises workers with a long history of intermittent exposure but without detectable signs of hand-arm vibration syndrome (HAVS). Yet, most of the published studies deal with developed HAVS cases, rarely discussing the biological processes that may be involved in degradation of manual dexterity and grip strength when it can be most beneficial - during the asymptomatic stage. In the present paper, a group of 31 male asymptomatic vibration-exposed workers (according to the Stockholm Workshop Scale) were compared against 30 male controls. They were tested using dynamometry and dexterimetry (modelling coarse and fine manual performance respectively) and cold provocation was done to detect possible differences in manual performance drop on these tests. The results showed reduced manual dexterity but no significant degradation in hand grip strength in the exposed subjects. This suggests that intermittent exposure profile and small cumulative vibration dose could only lead to a measurable deficit in manual dexterity but not hand grip strength even at non-negligible A(8) levels and long term exposures.
Hartmann, R C; Peters, O A; de Figueiredo, J A P; Rossi-Fedele, G
2018-04-28
The role and effect of glide path preparation in root canal treatment remain controversial. This systematic review aims to compare apical transportation and canal centring of different glide path preparation techniques, with or without subsequent engine-driven root canal preparation. A database search in PubMed, PubMed Central, Embase, Scopus, EBSCO Dentistry & Oral Sciences Source and Virtual Health Library was conducted, using appropriate key words to identify the effect of glide path preparation (or its absence) on apical transportation and canal centring. An assessment for the risk of bias in included studies was carried out. Amongst 2146 studies, 18 satisfied the inclusion criteria. Nine studies assessed glide path preparation per se, comparing apical transportation and canal centring of rotary systems and/or manual files; eleven further investigations examined the efficacy of the glide path prior to final canal preparation with different engine-driven systems. Risk of bias and other study design features with potential influence on study outcomes and clinical implications were assessed. Based on the available evidence, and within the limitation of the studies included, preparation of a glide path using rotary sequences performs similarly (in most of the component studies) or significantly better than manual preparation when assessing apical transportation or canal centring. When compared to the absence of a glide path, canal shaping following glide path preparation was of similar, or significantly better quality, in regard to apical transportation or canal centring. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Misclassification of OSA severity with automated scoring of home sleep recordings.
Aurora, R Nisha; Swartz, Rachel; Punjabi, Naresh M
2015-03-01
The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings. Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (≥ 3% and ≥ 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses. Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a ≥ 3% or ≥ 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the ≥ 3% and ≥ 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively. Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease. ClinicalTrials.gov; No.: NCT01503164; www.clinicaltrials.gov.
Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings
Aurora, R. Nisha; Swartz, Rachel
2015-01-01
BACKGROUND: The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings. METHODS: Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (≥ 3% and ≥ 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses. RESULTS: Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a ≥ 3% or ≥ 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the ≥ 3% and ≥ 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively. CONCLUSIONS: Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01503164; www.clinicaltrials.gov PMID:25411804
Ousehal, Lahcen; Lazrak, Laila; Es-Said, Rabia; Hamdoune, Hind; Elquars, Farid; Khadija, Amine
2011-03-01
Multibracket orthodontic appliances increase dental plaque retention and make teethbrushing more difficult for patients. As a result, advice from the orthodontist on oral hygiene along with patient motivation regarding teethbrushing are particularly important. The aim of this study was to compare the efficacy of electric toothbrushes with that of manual brushing associated with mouth-rinses comprising chlorhexidine (0.12%) and 0% alcohol. To this end, 84 patients receiving current orthodontic treatment were randomly selected from patients treated at the Dento-Facial Orthopedics department in the Casablanca Dental Consultation and Treatment Center. Selected patients were divided into three groups: Group 1: manual teethbrushing; Group 2: electric teethbrushing; Group 3: manual brushing combined with mouth rinse. Oral hygiene was assessed using the Loe-Silness plaque and gingival indices. Measurements were made before and 4 weeks after the observation period. Results were subjected to statistical comparison in order to determine the group showing greatest improvement and to deduce the best means of controlling bacterial plaque. The electric toothbrush and the chlorhexidine mouth rinse appear to control dental plaque more effectively than manual teethbrushing alone. Following this study, patients receiving multibracket treatment were invited to combine manual brushing with short clinical mouth-rinsing sessions or to use an electric toothbrush. Copyright © 2011 CEO. Published by Elsevier Masson SAS. All rights reserved.
Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.
2010-01-01
The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339
Kaser, Daniel J; Farland, Leslie V; Missmer, Stacey A; Racowsky, Catherine
2017-08-01
How does automated time-lapse annotation (Eeva™) compare to manual annotation of the same video images performed by embryologists certified in measuring durations of the 2-cell (P2; time to the 3-cell minus time to the 2-cell, or t3-t2) and 3-cell (P3; time to 4-cell minus time to the 3-cell, or t4-t3) stages? Manual annotation was superior to the automated annotation provided by Eeva™ version 2.2, because manual annotation assigned a rating to a higher proportion of embryos and yielded a greater sensitivity for blastocyst prediction than automated annotation. While use of the Eeva™ test has been shown to improve an embryologist's ability to predict blastocyst formation compared to Day 3 morphology alone, the accuracy of the automated image analysis employed by the Eeva™ system has never been compared to manual annotation of the same time-lapse markers by a trained embryologist. We conducted a prospective cohort study of embryos (n = 1477) cultured in the Eeva™ system (n = 8 microscopes) at our institution from August 2014 to February 2016. Embryos were assigned a blastocyst prediction rating of High (H), Medium (M), Low (L), or Not Rated (NR) by Eeva™ version 2.2 according to P2 and P3. An embryologist from a team of 10, then manually annotated each embryo and if the automated and manual ratings differed, a second embryologist independently annotated the embryo. If both embryologists disagreed with the automated Eeva™ rating, then the rating was classified as discordant. If the second embryologist agreed with the automated Eeva™ score, the rating was not considered discordant. Spearman's correlation (ρ), weighted kappa statistics and the intra-class correlation (ICC) coefficients with 95% confidence intervals (CI) between Eeva™ and manual annotation were calculated, as were the proportions of discordant embryos, and the sensitivity, specificity, positive predictive value (PPV) and NPV of each method for blastocyst prediction. The distribution of H, M and L ratings differed by annotation method (P < 0.0001). The correlation between Eeva™ and manual annotation was higher for P2 (ρ = 0.75; ICC = 0.82; 95% CI 0.82-0.83) than for P3 (ρ = 0.39; ICC = 0.20; 95% CI 0.16-0.26). Eeva™ was more likely than an embryologist to rate an embryo as NR (11.1% vs. 3.0%, P < 0.0001). Discordance occurred in 30.0% (443/1477) of all embryos and was not associated with factors such as Day 3 cell number, fragmentation, symmetry or presence of abnormal cleavage. Rather, discordance was associated with direct cleavage (P2 ≤ 5 h) and short P3 (≤0.25 h), and also factors intrinsic to the Eeva™ system, such as the automated rating (proportion of discordant embryos by rating: H: 9.3%; M: 18.1%; L: 41.3%; NR: 31.4%; P < 0.0001), microwell location (peripheral: 31.2%; central: 23.8%; P = 0.02) and Eeva™ microscope (n = 8; range 22.9-42.6%; P < 0.0001). Manual annotation upgraded 82.6% of all discordant embryos from a lower to a higher rating, and improved the sensitivity for predicting blastocyst formation. One team of embryologists performed the manual annotations; however, the study staff was trained and certified by the company sponsor. Only two time-lapse markers were evaluated, so the results are not generalizable to other parameters; likewise, the results are not generalizable to future versions of Eeva™ or other automated image analysis systems. Based on the proportion of discordance and the improved performance of manual annotation, clinics using the Eeva™ system should consider manual annotation of P2 and P3 to confirm the automated ratings generated by Eeva™. These data were acquired in a study funded by Progyny, Inc. There are no competing interests. N/A. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
Comparison of tongue interface with keyboard for control of an assistive robotic arm.
Struijk, Lotte N S Andreasen; Lontis, Romulus
2017-07-01
This paper demonstrates how an assistive 6 DoF robotic arm with a gripper can be controlled manually using a tongue interface. The proposed method suggests that it possible for a user to manipulate the surroundings with his or her tongue using the inductive tongue control system as deployed in this study. The sensors of an inductive tongue-computer interface were mapped to the Cartesian control of an assistive robotic arm. The resulting control system was tested manually in order to compare manual control of the robot using a standard keyboard and using the tongue interface. Two healthy subjects controlled the robotic arm to precisely move a bottle of water from one location to another. The results shows that the tongue interface was able to fully control the robotic arm in a similar manner as the standard keyboard resulting in the same number of successful manipulations and an average increase in task duration of up to 30% as compared with the standard keyboard.
da Frota, Matheus Franco; Filho, Idomeo Bonetti; Berbert, Fábio Luiz Camargo Villela; Sponchiado, Emilio Carlos; Marques, André Augusto Franco; Garcia, Lucas da Fonseca Roberti
2013-01-01
The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.
Experimental analysis of robot-assisted needle insertion into porcine liver.
Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie
2015-01-01
How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.
[Stapler versus manual anastomosis in gastrointestinal surgery].
Moreno-Gonzalez, E; Vara-Thorbeck, R
1987-01-01
The comparative effectiveness of manual and auto-sutured anastomoses after total gastrectomy (107 cases), low anterior rectal resection (100 cases) and right hemicolectomy (34 cases) is studied. In the stapled series the incidence of anastomotic leakage was somewhat less, although benign stenosis occurred more frequently than with hand-sutured anastomoses. However, this could not be statistically demonstrated. In the authors' view, the main advantages of the use of staplers are the shortening of operating time and the lessening of septic steps.
Load research manual. Volume 2: Fundamentals of implementing load research procedures
NASA Astrophysics Data System (ADS)
1980-11-01
This manual will assist electric utilities and state regulatory authorities in investigating customer electricity demand as part of cost-of-service studies, rate design, marketing research, system design, load forecasting, rate reform analysis, and load management research. Load research procedures are described in detail. Research programs at three utilities are compared: Carolina Power and Light Company, Long Island Lighting Company, and Southern California Edison Company. A load research bibliography and glossaries of load research and statistical terms are also included.
Shahedi, Maysam; Cool, Derek W; Romagnoli, Cesare; Bauman, Glenn S; Bastian-Jordan, Matthew; Gibson, Eli; Rodrigues, George; Ahmad, Belal; Lock, Michael; Fenster, Aaron; Ward, Aaron D
2014-11-01
Three-dimensional (3D) prostate image segmentation is useful for cancer diagnosis and therapy guidance, but can be time-consuming to perform manually and involves varying levels of difficulty and interoperator variability within the prostatic base, midgland (MG), and apex. In this study, the authors measured accuracy and interobserver variability in the segmentation of the prostate on T2-weighted endorectal magnetic resonance (MR) imaging within the whole gland (WG), and separately within the apex, midgland, and base regions. The authors collected MR images from 42 prostate cancer patients. Prostate border delineation was performed manually by one observer on all images and by two other observers on a subset of ten images. The authors used complementary boundary-, region-, and volume-based metrics [mean absolute distance (MAD), Dice similarity coefficient (DSC), recall rate, precision rate, and volume difference (ΔV)] to elucidate the different types of segmentation errors that they observed. Evaluation for expert manual and semiautomatic segmentation approaches was carried out. Compared to manual segmentation, the authors' semiautomatic approach reduces the necessary user interaction by only requiring an indication of the anteroposterior orientation of the prostate and the selection of prostate center points on the apex, base, and midgland slices. Based on these inputs, the algorithm identifies candidate prostate boundary points using learned boundary appearance characteristics and performs regularization based on learned prostate shape information. The semiautomated algorithm required an average of 30 s of user interaction time (measured for nine operators) for each 3D prostate segmentation. The authors compared the segmentations from this method to manual segmentations in a single-operator (mean whole gland MAD = 2.0 mm, DSC = 82%, recall = 77%, precision = 88%, and ΔV = - 4.6 cm(3)) and multioperator study (mean whole gland MAD = 2.2 mm, DSC = 77%, recall = 72%, precision = 86%, and ΔV = - 4.0 cm(3)). These results compared favorably with observed differences between manual segmentations and a simultaneous truth and performance level estimation reference for this data set (whole gland differences as high as MAD = 3.1 mm, DSC = 78%, recall = 66%, precision = 77%, and ΔV = 15.5 cm(3)). The authors found that overall, midgland segmentation was more accurate and repeatable than the segmentation of the apex and base, with the base posing the greatest challenge. The main conclusions of this study were that (1) the semiautomated approach reduced interobserver segmentation variability; (2) the segmentation accuracy of the semiautomated approach, as well as the accuracies of recently published methods from other groups, were within the range of observed expert variability in manual prostate segmentation; and (3) further efforts in the development of computer-assisted segmentation would be most productive if focused on improvement of segmentation accuracy and reduction of variability within the prostatic apex and base.
A Markerless 3D Computerized Motion Capture System Incorporating a Skeleton Model for Monkeys.
Nakamura, Tomoya; Matsumoto, Jumpei; Nishimaru, Hiroshi; Bretas, Rafael Vieira; Takamura, Yusaku; Hori, Etsuro; Ono, Taketoshi; Nishijo, Hisao
2016-01-01
In this study, we propose a novel markerless motion capture system (MCS) for monkeys, in which 3D surface images of monkeys were reconstructed by integrating data from four depth cameras, and a skeleton model of the monkey was fitted onto 3D images of monkeys in each frame of the video. To validate the MCS, first, estimated 3D positions of body parts were compared between the 3D MCS-assisted estimation and manual estimation based on visual inspection when a monkey performed a shuttling behavior in which it had to avoid obstacles in various positions. The mean estimation error of the positions of body parts (3-14 cm) and of head rotation (35-43°) between the 3D MCS-assisted and manual estimation were comparable to the errors between two different experimenters performing manual estimation. Furthermore, the MCS could identify specific monkey actions, and there was no false positive nor false negative detection of actions compared with those in manual estimation. Second, to check the reproducibility of MCS-assisted estimation, the same analyses of the above experiments were repeated by a different user. The estimation errors of positions of most body parts between the two experimenters were significantly smaller in the MCS-assisted estimation than in the manual estimation. Third, effects of methamphetamine (MAP) administration on the spontaneous behaviors of four monkeys were analyzed using the MCS. MAP significantly increased head movements, tended to decrease locomotion speed, and had no significant effect on total path length. The results were comparable to previous human clinical data. Furthermore, estimated data following MAP injection (total path length, walking speed, and speed of head rotation) correlated significantly between the two experimenters in the MCS-assisted estimation (r = 0.863 to 0.999). The results suggest that the presented MCS in monkeys is useful in investigating neural mechanisms underlying various psychiatric disorders and developing pharmacological interventions.
Evaluation of a commercial automatic treatment planning system for prostate cancers.
Nawa, Kanabu; Haga, Akihiro; Nomoto, Akihiro; Sarmiento, Raniel A; Shiraishi, Kenshiro; Yamashita, Hideomi; Nakagawa, Keiichi
2017-01-01
Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle 3 radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle 3 uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
A comparison of manual and quantitative elbow strength testing.
Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R
2012-10-01
The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.
Manual therapy and exercise for rotator cuff disease.
Page, Matthew J; Green, Sally; McBain, Brodwen; Surace, Stephen J; Deitch, Jessica; Lyttle, Nicolette; Mrocki, Marshall A; Buchbinder, Rachelle
2016-06-10
Management of rotator cuff disease often includes manual therapy and exercise, usually delivered together as components of a physical therapy intervention. This review is one of a series of reviews that form an update of the Cochrane review, 'Physiotherapy interventions for shoulder pain'. To synthesise available evidence regarding the benefits and harms of manual therapy and exercise, alone or in combination, for the treatment of people with rotator cuff disease. We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (January 1966 to March 2015), Ovid EMBASE (January 1980 to March 2015), CINAHL Plus (EBSCO, January 1937 to March 2015), ClinicalTrials.gov and the WHO ICTRP clinical trials registries up to March 2015, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials, to identify potentially relevant trials. We included randomised and quasi-randomised trials, including adults with rotator cuff disease, and comparing any manual therapy or exercise intervention with placebo, no intervention, a different type of manual therapy or exercise or any other intervention (e.g. glucocorticoid injection). Interventions included mobilisation, manipulation and supervised or home exercises. Trials investigating the primary or add-on effect of manual therapy and exercise were the main comparisons of interest. Main outcomes of interest were overall pain, function, pain on motion, patient-reported global assessment of treatment success, quality of life and the number of participants experiencing adverse events. Two review authors independently selected trials for inclusion, extracted the data, performed a risk of bias assessment and assessed the quality of the body of evidence for the main outcomes using the GRADE approach. We included 60 trials (3620 participants), although only 10 addressed the main comparisons of interest. Overall risk of bias was low in three, unclear in 14 and high in 43 trials. We were unable to perform any meta-analyses because of clinical heterogeneity or incomplete outcome reporting. One trial compared manual therapy and exercise with placebo (inactive ultrasound therapy) in 120 participants with chronic rotator cuff disease (high quality evidence). At 22 weeks, the mean change in overall pain with placebo was 17.3 points on a 100-point scale, and 24.8 points with manual therapy and exercise (adjusted mean difference (MD) 6.8 points, 95% confidence interval (CI) -0.70 to 14.30 points; absolute risk difference 7%, 1% fewer to 14% more). Mean change in function with placebo was 15.6 points on a 100-point scale, and 22.4 points with manual therapy and exercise (adjusted MD 7.1 points, 95% CI 0.30 to 13.90 points; absolute risk difference 7%, 1% to 14% more). Fifty-seven per cent (31/54) of participants reported treatment success with manual therapy and exercise compared with 41% (24/58) of participants receiving placebo (risk ratio (RR) 1.39, 95% CI 0.94 to 2.03; absolute risk difference 16% (2% fewer to 34% more). Thirty-one per cent (17/55) of participants reported adverse events with manual therapy and exercise compared with 8% (5/61) of participants receiving placebo (RR 3.77, 95% CI 1.49 to 9.54; absolute risk difference 23% (9% to 37% more). However adverse events were mild (short-term pain following treatment).Five trials (low quality evidence) found no important differences between manual therapy and exercise compared with glucocorticoid injection with respect to overall pain, function, active shoulder abduction and quality of life from four weeks up to 12 months. However, global treatment success was more common up to 11 weeks in people receiving glucocorticoid injection (low quality evidence). One trial (low quality evidence) showed no important differences between manual therapy and exercise and arthroscopic subacromial decompression with respect to overall pain, function, active range of motion and strength at six and 12 months, or global treatment success at four to eight years. One trial (low quality evidence) found that manual therapy and exercise may not be as effective as acupuncture plus dietary counselling and Phlogenzym supplement with respect to overall pain, function, active shoulder abduction and quality life at 12 weeks. We are uncertain whether manual therapy and exercise improves function more than oral non-steroidal anti-inflammatory drugs (NSAID), or whether combining manual therapy and exercise with glucocorticoid injection provides additional benefit in function over glucocorticoid injection alone, because of the very low quality evidence in these two trials.Fifty-two trials investigated effects of manual therapy alone or exercise alone, and the evidence was mostly very low quality. There was little or no difference in patient-important outcomes between manual therapy alone and placebo, no treatment, therapeutic ultrasound and kinesiotaping, although manual therapy alone was less effective than glucocorticoid injection. Exercise alone led to less improvement in overall pain, but not function, when compared with surgical repair for rotator cuff tear. There was little or no difference in patient-important outcomes between exercise alone and placebo, radial extracorporeal shockwave treatment, glucocorticoid injection, arthroscopic subacromial decompression and functional brace. Further, manual therapy or exercise provided few or no additional benefits when combined with other physical therapy interventions, and one type of manual therapy or exercise was rarely more effective than another. Despite identifying 60 eligible trials, only one trial compared a combination of manual therapy and exercise reflective of common current practice to placebo. We judged it to be of high quality and found no clinically important differences between groups in any outcome. Effects of manual therapy and exercise may be similar to those of glucocorticoid injection and arthroscopic subacromial decompression, but this is based on low quality evidence. Adverse events associated with manual therapy and exercise are relatively more frequent than placebo but mild in nature. Novel combinations of manual therapy and exercise should be compared with a realistic placebo in future trials. Further trials of manual therapy alone or exercise alone for rotator cuff disease should be based upon a strong rationale and consideration of whether or not they would alter the conclusions of this review.
Peng, Le; Zhang, Chao; Zhou, Lan; Zuo, Hong-Xia; He, Xiao-Kuo; Niu, Yu-Ming
2018-04-01
To investigate the effectiveness of traditional manual acupuncture combined with rehabilitation therapy versus rehabilitation therapy alone for shoulder hand syndrome after stroke. PubMed, EMBASE, the Cochrane Library, Chinese Biomedicine Database, China National Knowledge Infrastructure, VIP Information Database, Wan Fang Database and reference lists of the eligible studies were searched up to July 2017 for relevant studies. Randomized controlled trials that compared the combined effects of traditional manual acupuncture and rehabilitation therapy to rehabilitation therapy alone for shoulder hand syndrome after stroke were included. Two reviewers independently screened the searched records, extracted the data and assessed risk of bias of the included studies. The treatment effect sizes were pooled in a meta-analysis using RevMan 5.3 software. A total of 20 studies involving 1918 participants were included in this study. Compared to rehabilitation therapy alone, the combined therapy significantly reduced pain on the visual analogue scale and improved limb movement on the Fugl-Meyer Assessment scale and the performance of activities of daily living (ADL) on the Barthel Index scale or Modified Barthel Index scale. Of these, the visual analogue scale score changes were significantly higher (mean difference = 1.49, 95% confidence interval = 1.15-1.82, P < 0.00001) favoring the combined therapy after treatment, with severe heterogeneity ( I 2 = 71%, P = 0.0005). Current evidence suggests that traditional manual acupuncture integrated with rehabilitation therapy is more effective in alleviating pain, improving limb movement and ADL. However, considering the relatively low quality of available evidence, further rigorously designed and large-scale randomized controlled trials are needed to confirm the results.
Said, Halima M; Krishnamani, Keshav; Omar, Shaheed V; Dreyer, Andries W; Sansom, Bianca; Fallows, Dorothy; Ismail, Nazir A
2016-10-01
The manual IS6110-based restriction fragment length polymorphism (RFLP) typing method is highly discriminatory; however, it is laborious and technically demanding, and data exchange remains a challenge. In an effort to improve IS6110-based RFLP to make it a faster format, DuPont Molecular Diagnostics recently introduced the IS6110-PvuII kit for semiautomated typing of Mycobacterium tuberculosis using the RiboPrinter microbial characterization system. This study aimed to evaluate the semiautomated RFLP typing against the standard manual method. A total of 112 isolates collected between 2013 and 2014 were included. All isolates were genotyped using manual and semiautomated RFLP typing methods. Clustering rates and discriminatory indexes were compared between methods. The overall performance of semiautomated RFLP compared to manual typing was excellent, with high discriminatory index (0.990 versus 0.995, respectively) and similar numbers of unique profiles (72 versus 74, respectively), numbers of clustered isolates (33 versus 31, respectively), cluster sizes (2 to 6 and 2 to 5 isolates, respectively), and clustering rates (21.9% and 17.1%, respectively). The semiautomated RFLP system is technically simple and significantly faster than the manual RFLP method (8 h versus 5 days). The analysis is fully automated and generates easily manageable databases of standardized fingerprints that can be easily exchanged between laboratories. Based on its high-throughput processing with minimal human effort, the semiautomated RFLP can be a very useful tool as a first-line method for routine typing of M. tuberculosis isolates, especially where Beijing strains are highly prevalent, followed by manual RFLP typing if resolution is not achieved, thereby saving time and labor. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Establishing a gold standard for manual cough counting: video versus digital audio recordings
Smith, Jaclyn A; Earis, John E; Woodcock, Ashley A
2006-01-01
Background Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. Methods We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. Results The median cough frequency was 17.8 (IQR 5.9–28.7) cough sounds per hour in the video recordings and 17.7 (6.0–29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD ± 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2–4 hours of analysis per recording. Conclusion Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment. PMID:16887019
Adragão, Pedro Pulido; Cavaco, Diogo; Ferreira, António Miguel; Costa, Francisco Moscoso; Parreira, Leonor; Carmo, Pedro; Morgado, Francisco Bello; Santos, Katya Reis; Santos, Pedro Galvão; Carvalho, Maria Salomé; Durazzo, Anai; Marques, Hugo; Gonçalves, Pedro Araújo; Raposo, Luís; Mendes, Miguel
2016-03-01
Whether or not the potential advantages of using a magnetic navigation system (MNS) translate into improved outcomes in patients undergoing atrial fibrillation (AF) ablation is a question that remains unanswered. In this observational registry study, we used propensity-score matching to compare the outcomes of patients with symptomatic drug-refractory AF who underwent catheter ablation using MNS with the outcomes of those who underwent catheter ablation using conventional manual navigation. Among 1,035 eligible patients, 287 patients in each group had similar propensity scores and were included in the analysis. The primary efficacy outcome was the rate of AF relapse after a 3-month blanking period. At a mean follow-up of 2.6 ± 1.5 years, AF ablation with MNS was associated with a similar risk of AF relapse as compared with manual navigation (18.4% per year and 22.3% per year, respectively; hazard ratio 0.81, 95% CI 0.63-1.05; P = 0.108). Major complications occurred in two patients (0.7%) using MNS, and in six patients (2.1%) undergoing manually navigated ablation (P = 0.286). Fluoroscopy times were 21 ± 10 minutes in the manual navigation group, and 12 ± 9 minutes in the MNS group (P < 0.001), whereas total procedure times were 152 ± 52 minutes and 213 ± 58 minutes, respectively (P < 0.001). In this propensity-score matched comparison, magnetic navigation and conventional manual AF ablations seem to have similar relapse rates and a similar risk of complications. AF ablations with magnetic navigation take longer to perform but expose patients to significantly shorter fluoroscopy times. © 2015 Wiley Periodicals, Inc.
Magnetic versus manual catheter navigation for ablation of free wall accessory pathways in children.
Kim, Jeffrey J; Macicek, Scott L; Decker, Jamie A; Kertesz, Naomi J; Friedman, Richard A; Cannon, Bryan C
2012-08-01
Transcatheter ablation of accessory pathway (AP)-mediated tachycardia is routinely performed in children. Little data exist regarding the use of magnetic navigation (MN) and its potential benefits for ablation of AP-mediated tachycardia in this population. We performed a retrospective review of prospectively gathered data in children undergoing radiofrequency ablation at our institution since the installation of MN (Stereotaxis Inc, St. Louis, MO) in March 2009. The efficacy and safety between an MN-guided approach and standard manual techniques for mapping and ablation of AP-mediated tachycardia were compared. During the 26-month study period, 145 patients underwent radiofrequency ablation for AP-mediated tachycardia. Seventy-three patients were ablated with MN and 72 with a standard manual approach. There were no significant differences in demographic factors between the 2 groups with a mean cohort age of 13.1±4.0 years. Acute success rates were equivalent with 68 of 73 (93.2%) patients in the MN group being successfully ablated versus 68 of 72 (94.4%) patients in the manual group (P=0.889). During a median follow-up of 21.4 months, there were no recurrences in the MN group and 2 recurrences in the manual group (P=0.388). There were no differences in time to effect, number of lesions delivered, or average ablation power. There was also no difference in total procedure time, but fluoroscopy time was significantly reduced in the MN group at 14.0 (interquartile range, 3.8-23.9) minutes compared with the manual group at 28.1 (interquartile range, 15.3-47.3) minutes (P<0.001). There were no complications in either group. MN is a safe and effective approach to ablate AP-mediated tachycardia in children.
Kaur, Indreshpal; Zulovich, Jane M; Gonzalez, Marissa; McGee, Kara M; Ponweera, Nirmali; Thandi, Daljit; Alvarez, Enrique F; Annandale, Kathy; Flagge, Frank; Rezvani, Katayoun; Shpall, Elizabeth
2017-03-01
Umbilical cord blood (CB) is being used as a source of hematopoietic stem cells (HSCs) and immune cells to treat many disorders. Because these cells are present in low numbers in CB, investigators have developed strategies to expand HSCs and other immune cells such as natural killer (NK) cells. The initial step in this process is to enrich mononuclear cells (MNCs) while depleting unwanted cells. The manual method of MNC enrichment is routinely used by many centers; however, it is an open system, time-consuming and operator dependent. For clinical manufacturing, it is important to have a closed system to avoid microbial contamination. In this study, we optimized an automated, closed system (Sepax) for enriching MNCs from cryopreserved CB units. Using Sepax, we observed higher recovery of total nucleated cells (TNC), CD34 + cells, NK cells and monocytes when compared to manual enrichment, despite similar TNC and CD34 + viability with the two methods. Even though the depletion of red blood cells, granulocytes and platelets was superior using the manual method, significantly higher CFU-GM were obtained in MNCs enriched using Sepax compared to the manual method. This is likely related to the fact that the automated Sepax significantly shortened the processing time (Sepax: 74 - 175 minutes versus manual method: 180 - 290 minutes). The use of DNAse and MgCl 2 during the Sepax thaw and wash procedure prevents clumping of cells and loss of viability, resulting in improved post-thaw cell recovery. We optimized enrichment of MNCs from cryopreserved CB products in a closed system using the Sepax which is a walk away and automated processing system. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Daniel, Kaemmerer; Maria, Athelogou; Amelie, Lupp; Isabell, Lenhardt; Stefan, Schulz; Luisa, Peter; Merten, Hommann; Vikas, Prasad; Gerd, Binnig; Paul, Baum Richard
2014-01-01
Background: Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT. Methods: We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score “BB1” was created for comparing the manual and automated analysis of SSTR expression. Results: BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).Conclusion: Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides (“virtual microscopy”), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging. PMID:25197368
Effects of developer depletion on image quality of Kodak Insight and Ektaspeed Plus films.
Casanova, M S; Casanova, M L S; Haiter-Neto, F
2004-03-01
To evaluate the effect of processing solution depletion on the image quality of F-speed dental X-ray film (Insight), compared with Ektaspeed Plus. The films were exposed with a phantom and developed in manual and automatic conditions, in fresh and progressively depleted solutions. The comparison was based on densitometric analysis and subjective appraisal. The processing solution depletion presented a different behaviour depending on whether manual or automatic technique was used. The films were distinctly affected by depleted processing solutions. The developer depletion was faster in automatic than manual conditions. Insight film was more resistant than Ektaspeed Plus to the effects of processing solution depletion. In the present study there was agreement between the objective and subjective appraisals.
Driving Performance After Self-Regulated Control Transitions in Highly Automated Vehicles.
Eriksson, Alexander; Stanton, Neville A
2017-12-01
This study aims to explore whether driver-paced, noncritical transitions of control may counteract some of the aftereffects observed in the contemporary literature, resulting in higher levels of vehicle control. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control, resulting in seemingly scrambled control when manual control is resumed. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper or monitor the system and relinquish or resume control from the automation when prompted by vehicle systems. Driving performance in terms of lane positioning and steering behavior was assessed for 20 seconds post resuming control to capture the resulting level of control. It was found that lane positioning was virtually unaffected for the duration of the 20-second time span in both automated conditions compared to the manual baseline when drivers resumed manual control; however, significant increases in the standard deviation of steering input were found for both automated conditions compared to baseline. No significant differences were found between the two automated conditions. The results indicate that when drivers self-paced the transfer back to manual control they exhibit less of the detrimental effects observed in system-paced conditions. It was shown that self-paced transitions could reduce the risk of accidents near the edge of the operational design domain. Vehicle manufacturers must consider these benefits when designing contemporary systems.
González-López, Santiago; Martín-Altuve, Ernesto; Bolaños-Carmona, Victoria; Sánchez-Sánchez, Purificación; Rodríguez-Navarro, Alejandro
2013-10-01
To compare the percentage of collagen exposed in dentin root thirds after two irrigation protocols with manual or rotary instrumentation using two methacrylate resin-based sealers. Forty-eight single-root human teeth were prepared with manual (n = 24) or nickeltitanium ProFile rotary (n = 24) instrumentation, using 5% NaOCl between instruments and 5 ml 17% EDTA as final irrigant or 20% citric acid + 2% chlorhexidine (CHX) between instruments and as the final irrigant. RealSeal or EndoREZ were used as filling materials. One 1-mm slice per third was abraded and stained with Masson's trichrome method. Mean exposed collagen values were obtained in four areas from each section (at 60X magnification) and a complete factorial ANOVA was used to analyze the influence of the study variables. Non-parametric Mann-Whitney's test was used to compare groups. Differences with p < 0.05 were considered significant. A significantly higher percentage of collagen was exposed in all thirds with the use of the 20% citric acid + 2% CHX protocol with rotary vs manual instrumentation, but percent collagen exposed did not differ as a function of the filling material. After the 5% NaOCl + 17% EDTA protocol, the percentage of collagen exposed did not differ between rotary and manual instrumentation but was higher with the use of RealSeal. The highest percentage exposure of collagen was with 20% citric acid + 2% CHX using rotary instrumentation, regardless of the filling material.
Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola
2012-11-01
The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.
Lüddemann, Tobias; Egger, Jan
2016-04-01
Among all types of cancer, gynecological malignancies belong to the fourth most frequent type of cancer among women. In addition to chemotherapy and external beam radiation, brachytherapy is the standard procedure for the treatment of these malignancies. In the progress of treatment planning, localization of the tumor as the target volume and adjacent organs of risks by segmentation is crucial to accomplish an optimal radiation distribution to the tumor while simultaneously preserving healthy tissue. Segmentation is performed manually and represents a time-consuming task in clinical daily routine. This study focuses on the segmentation of the rectum/sigmoid colon as an organ-at-risk in gynecological brachytherapy. The proposed segmentation method uses an interactive, graph-based segmentation scheme with a user-defined template. The scheme creates a directed two-dimensional graph, followed by the minimal cost closed set computation on the graph, resulting in an outlining of the rectum. The graph's outline is dynamically adapted to the last calculated cut. Evaluation was performed by comparing manual segmentations of the rectum/sigmoid colon to results achieved with the proposed method. The comparison of the algorithmic to manual result yielded a dice similarity coefficient value of [Formula: see text], in comparison to [Formula: see text] for the comparison of two manual segmentations by the same physician. Utilizing the proposed methodology resulted in a median time of [Formula: see text], compared to 300 s needed for pure manual segmentation.
Martins, Wagner Rodrigues; Blasczyk, Juscelino Castro; Aparecida Furlan de Oliveira, Micaele; Lagôa Gonçalves, Karina Ferreira; Bonini-Rocha, Ana Clara; Dugailly, Pierre-Michel; de Oliveira, Ricardo Jacó
2016-02-01
Temporomandibular joint disorder (TMD) requires a complex diagnostic and therapeutic approach, which usually involves a multidisciplinary management. Among these treatments, musculoskeletal manual techniques are used to improve health and healing. To assess the effectiveness of musculoskeletal manual approach in temporomandibular joint disorder patients. A systematic review with meta-analysis. During August 2014 a systematic review of relevant databases (PubMed, The Cochrane Library, PEDro and ISI web of knowledge) was performed to identify controlled clinical trials without date restriction and restricted to the English language. Clinical outcomes were pain and range of motion focalized in temporomandibular joint. The mean difference (MD) or standard mean difference (SMD) with 95% confidence intervals (CIs) and overall effect size were calculated at every post treatment. The PEDro scale was used to demonstrate the quality of the included studies. From the 308 articles identified by the search strategy, 8 articles met the inclusion criteria. The meta-analysis showed a significant difference (p < 0.0001) and large effect on active mouth opening (SMD, 0.83; 95% CI, 0.42 to 1.25) and on pain during active mouth opening (MD, 1.69; 95% CI, 1.09 to 2.30) in favor of musculoskeletal manual techniques when compared to other conservative treatments for TMD. Musculoskeletal manual approaches are effective for treating TMD. In the short term, there is a larger effect regarding the latter when compared to other conservative treatments for TMD. Copyright © 2015 Elsevier Ltd. All rights reserved.
O'Connor Mooney, Rory; Davis, Niall Francis; Hoey, David; Hogan, Lisa; McGloughlin, Timothy M; Walsh, Michael T
2016-01-01
To investigate the repeatability of automatic decellularisation of porcine aortae using a non-enzymatic approach, addressing current limitations associated with other automatic decellularisation processes. Individual porcine aortae (n = 3) were resected and every third segment (n = 4) was allocated to one of three different groups: a control or a manually or automatically decellularised group. Manual and automatic decellularisation was performed using Triton X-100 (2% v/v) and sodium deoxycholate. Protein preservation and the elimination of a galactosyl-α(1,3)galactose (GAL) epitope were measured using immunohistochemistry and protein binding assays. The presence of residual DNA was determined with gel electrophoresis and spectrophotometry. Scaffold integrity was characterised with scanning electron microscopy and uni-axial tensile testing. Manual and automatic results were compared to one another, to control groups and to current gold standards. The results were comparable to those of current gold standard decellularisation techniques. Successful repeatability was achieved, both manually and automatically, with little effect on mechanical characteristics. Complete acellularity was not confirmed in either decellularisation group. Protein preservation was consistent in both the manually and automatically decellularised groups and between each individual aorta. Elimination of GAL was not achieved. Repeatable automatic decellularisation of porcine aortae is feasible using a Triton X-100-sodium deoxycholate protocol. Protein preservation was satisfactory; however, gold standard thresholds for permissible residual DNA levels were not achieved. Future research will focus on addressing this issue by optimisation of the existing protocol for thick tissues. © 2016 S. Karger AG, Basel.
Interactive and scale invariant segmentation of the rectum/sigmoid via user-defined templates
NASA Astrophysics Data System (ADS)
Lüddemann, Tobias; Egger, Jan
2016-03-01
Among all types of cancer, gynecological malignancies belong to the 4th most frequent type of cancer among women. Besides chemotherapy and external beam radiation, brachytherapy is the standard procedure for the treatment of these malignancies. In the progress of treatment planning, localization of the tumor as the target volume and adjacent organs of risks by segmentation is crucial to accomplish an optimal radiation distribution to the tumor while simultaneously preserving healthy tissue. Segmentation is performed manually and represents a time-consuming task in clinical daily routine. This study focuses on the segmentation of the rectum/sigmoid colon as an Organ-At-Risk in gynecological brachytherapy. The proposed segmentation method uses an interactive, graph-based segmentation scheme with a user-defined template. The scheme creates a directed two dimensional graph, followed by the minimal cost closed set computation on the graph, resulting in an outlining of the rectum. The graphs outline is dynamically adapted to the last calculated cut. Evaluation was performed by comparing manual segmentations of the rectum/sigmoid colon to results achieved with the proposed method. The comparison of the algorithmic to manual results yielded to a Dice Similarity Coefficient value of 83.85+/-4.08%, in comparison to 83.97+/-8.08% for the comparison of two manual segmentations of the same physician. Utilizing the proposed methodology resulted in a median time of 128 seconds per dataset, compared to 300 seconds needed for pure manual segmentation.
ERIC Educational Resources Information Center
Savariaux, Christophe; Badin, Pierre; Samson, Adeline; Gerber, Silvain
2017-01-01
Purpose: This study compares the precision of the electromagnetic articulographs used in speech research: Northern Digital Instruments' Wave and Carstens' AG200, AG500, and AG501 systems. Method: The fluctuation of distances between 3 pairs of sensors attached to a manually rotated device that can position them inside the measurement volumes was…
Manual dexterity aptitude testing: a soap carving study.
Tang, Christopher G; Hilsinger, Raymond L; Cruz, Raul M; Schloegel, Luke J; Byl, Fred M; Rasgon, Barry M
2014-03-01
Currently there are few validated metrics for predicting surgical skill among otolaryngology residency applicants. To determine whether manual dexterity aptitude testing in the form of soap carving during otolaryngology residency interviews at Kaiser Permanente Medical Center Oakland predicts surgical skill at the time of graduation from otolaryngology residency programs. This study was conducted to determine how applicants with the best and worst soap carvings compared at the time of graduation with respect to various metrics including visuospatial ability and manual dexterity. Over the last 25 years, applicants to the residency program at Kaiser Permanente Oakland were required to carve soap during their residency interview. The 3 best and 3 worst soap carvings from 1990 through 2006 were determined. Of the individuals who carved those soaps, 62 qualified for the study and matriculated into otolaryngology residency programs. Surveys were sent to the 62 individuals' residency programs to evaluate those individuals on a 5-point Likert scale in various categories as well as to rank those individuals as being in the top 50% or bottom 50% of their graduating class. All else being equal, we hypothesized that applicants who had the manual dexterity and visuospatial skills to accurately carve a bar of soap would more likely possess the skills necessary to become a good surgeon. There was no difference between individuals with the best soap carvings and those with the worst soap carvings in all categories: cognitive knowledge, visuospatial ability, manual dexterity, decision making, and overall score (P > .10 for all categories). There was a 95% response rate, with 35 of 37 residency programs responding and 59 of 62 surveys returned. Manual dexterity aptitude testing in the form of soap carving does not appear to correlate with surgical skill at the time of graduation. Further studies need to be conducted to determine the role of manual dexterity and visuospatial aptitude testing in the otolaryngology application process.
Patel, Dishant; Bashetty, Kusum; Srirekha, A.; Archana, S.; Savitha, B.; Vijay, R.
2016-01-01
Aim: The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal. Materials and Methods: Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third. Statistical Analysis Used: Chi-squared test was used. Results: The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument. Conclusion: Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used. PMID:27994317
[Comparative study of device labeling regulation in U.S.A. and China].
Li, Fei; Wei, Jing; Ma, Yanbin; Li, Zhu
2010-09-01
To provide references for the evolvement of medical devices labeling and manual administration in China, By content analysis, 10 juristic documents relevant to device labeling and manual were collected from FDA website, compared to which, the federal regulation was mainly analyzed. There are five main differences of device labeling regulation between U.S.A. and China: juristic system, administrative scope, administrative target, characteristics and practice, A set of comprehensive juristic system for device labeling has been established by FDA. from which China should draw experience, to administrate the prescription devices and the over-the-counter devices in classification, and set up device labeling guidance, thus guarantee the safety and efficacy of device.
Functional MRI Preprocessing in Lesioned Brains: Manual Versus Automated Region of Interest Analysis
Garrison, Kathleen A.; Rogalsky, Corianne; Sheng, Tong; Liu, Brent; Damasio, Hanna; Winstein, Carolee J.; Aziz-Zadeh, Lisa S.
2015-01-01
Functional magnetic resonance imaging (fMRI) has significant potential in the study and treatment of neurological disorders and stroke. Region of interest (ROI) analysis in such studies allows for testing of strong a priori clinical hypotheses with improved statistical power. A commonly used automated approach to ROI analysis is to spatially normalize each participant’s structural brain image to a template brain image and define ROIs using an atlas. However, in studies of individuals with structural brain lesions, such as stroke, the gold standard approach may be to manually hand-draw ROIs on each participant’s non-normalized structural brain image. Automated approaches to ROI analysis are faster and more standardized, yet are susceptible to preprocessing error (e.g., normalization error) that can be greater in lesioned brains. The manual approach to ROI analysis has high demand for time and expertise, but may provide a more accurate estimate of brain response. In this study, commonly used automated and manual approaches to ROI analysis were directly compared by reanalyzing data from a previously published hypothesis-driven cognitive fMRI study, involving individuals with stroke. The ROI evaluated is the pars opercularis of the inferior frontal gyrus. Significant differences were identified in task-related effect size and percent-activated voxels in this ROI between the automated and manual approaches to ROI analysis. Task interactions, however, were consistent across ROI analysis approaches. These findings support the use of automated approaches to ROI analysis in studies of lesioned brains, provided they employ a task interaction design. PMID:26441816
La Macchia, Mariangela; Fellin, Francesco; Amichetti, Maurizio; Cianchetti, Marco; Gianolini, Stefano; Paola, Vitali; Lomax, Antony J; Widesott, Lamberto
2012-09-18
To validate, in the context of adaptive radiotherapy, three commercial software solutions for atlas-based segmentation. Fifteen patients, five for each group, with cancer of the Head&Neck, pleura, and prostate were enrolled in the study. In addition to the treatment planning CT (pCT) images, one replanning CT (rCT) image set was acquired for each patient during the RT course. Three experienced physicians outlined on the pCT and rCT all the volumes of interest (VOIs). We used three software solutions (VelocityAI 2.6.2 (V), MIM 5.1.1 (M) by MIMVista and ABAS 2.0 (A) by CMS-Elekta) to generate the automatic contouring on the repeated CT. All the VOIs obtained with automatic contouring (AC) were successively corrected manually. We recorded the time needed for: 1) ex novo ROIs definition on rCT; 2) generation of AC by the three software solutions; 3) manual correction of AC.To compare the quality of the volumes obtained automatically by the software and manually corrected with those drawn from scratch on rCT, we used the following indexes: overlap coefficient (DICE), sensitivity, inclusiveness index, difference in volume, and displacement differences on three axes (x, y, z) from the isocenter. The time saved by the three software solutions for all the sites, compared to the manual contouring from scratch, is statistically significant and similar for all the three software solutions. The time saved for each site are as follows: about an hour for Head&Neck, about 40 minutes for prostate, and about 20 minutes for mesothelioma. The best DICE similarity coefficient index was obtained with the manual correction for: A (contours for prostate), A and M (contours for H&N), and M (contours for mesothelioma). From a clinical point of view, the automated contouring workflow was shown to be significantly shorter than the manual contouring process, even though manual correction of the VOIs is always needed.
Semi-Automated Trajectory Analysis of Deep Ballistic Penetrating Brain Injury
Folio, Les; Solomon, Jeffrey; Biassou, Nadia; Fischer, Tatjana; Dworzak, Jenny; Raymont, Vanessa; Sinaii, Ninet; Wassermann, Eric M.; Grafman, Jordan
2016-01-01
Background Penetrating head injuries (PHIs) are common in combat operations and most have visible wound paths on computed tomography (CT). Objective We assess agreement between an automated trajectory analysis-based assessment of brain injury and manual tracings of encephalomalacia on CT. Methods We analyzed 80 head CTs with ballistic PHI from the Institutional Review Board approved Vietnam head injury registry. Anatomic reports were generated from spatial coordinates of projectile entrance and terminal fragment location. These were compared to manual tracings of the regions of encephalomalacia. Dice’s similarity coefficients, kappa, sensitivities, and specificities were calculated to assess agreement. Times required for case analysis were also compared. Results Results show high specificity of anatomic regions identified on CT with semiautomated anatomical estimates and manual tracings of tissue damage. Radiologist’s and medical students’ anatomic region reports were similar (Kappa 0.8, t-test p < 0.001). Region of probable injury modeling of involved brain structures was sensitive (0.7) and specific (0.9) compared with manually traced structures. Semiautomated analysis was 9-fold faster than manual tracings. Conclusion Our region of probable injury spatial model approximates anatomical regions of encephalomalacia from ballistic PHI with time-saving over manual methods. Results show potential for automated anatomical reporting as an adjunct to current practice of radiologist/neurosurgical review of brain injury by penetrating projectiles. PMID:23707123
Chang, Wen-Yu; Huang, Adam; Chen, Yin-Chun; Lin, Chi-Wei; Tsai, John; Yang, Chung-Kai; Huang, Yin-Tseng; Wu, Yi-Fan; Chen, Gwo-Shing
2015-05-03
To investigate the feasibility of manual segmentation by users of different backgrounds in a previously developed multifeature computer-aided diagnosis (CADx) system to classify melanocytic and non-melanocytic skin lesions based on conventional digital photographic images. In total, 347 conventional photographs of melanocytic and non-melanocytic skin lesions were retrospectively reviewed, and manually segmented by two groups of physicians, dermatologists and general practitioners, as well as by an automated segmentation software program, JSEG. The performance of CADx based on inputs from these two groups of physicians and that of the JSEG program was compared using feature agreement analysis. The estimated area under the receiver operating characteristic curve for classification of benign or malignant skin lesions based were comparable on individual segmentation by the gold standard (0.893, 95% CI 0.856 to 0.930), dermatologists (0.886, 95% CI 0.863 to 0.908), general practitioners (0.883, 95% CI 0.864 to 0.903) and JSEG (0.856, 95% CI 0.812 to 0.899). The agreement in the malignancy probability scores among the physicians was excellent (intraclass correlation coefficient: 0.91). By selecting an optimal cut-off value of malignancy probability score, the sensitivity and specificity were 80.07% and 81.47% for dermatologists and 79.90% and 80.20% for general practitioners. This study suggests that manual segmentation by general practitioners is feasible in the described CADx system for classifying benign and malignant skin lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Three-dimensional murine airway segmentation in micro-CT images
NASA Astrophysics Data System (ADS)
Shi, Lijun; Thiesse, Jacqueline; McLennan, Geoffrey; Hoffman, Eric A.; Reinhardt, Joseph M.
2007-03-01
Thoracic imaging for small animals has emerged as an important tool for monitoring pulmonary disease progression and therapy response in genetically engineered animals. Micro-CT is becoming the standard thoracic imaging modality in small animal imaging because it can produce high-resolution images of the lung parenchyma, vasculature, and airways. Segmentation, measurement, and visualization of the airway tree is an important step in pulmonary image analysis. However, manual analysis of the airway tree in micro-CT images can be extremely time-consuming since a typical dataset is usually on the order of several gigabytes in size. Automated and semi-automated tools for micro-CT airway analysis are desirable. In this paper, we propose an automatic airway segmentation method for in vivo micro-CT images of the murine lung and validate our method by comparing the automatic results to manual tracing. Our method is based primarily on grayscale morphology. The results show good visual matches between manually segmented and automatically segmented trees. The average true positive volume fraction compared to manual analysis is 91.61%. The overall runtime for the automatic method is on the order of 30 minutes per volume compared to several hours to a few days for manual analysis.
Validation of automatic segmentation of ribs for NTCP modeling.
Stam, Barbara; Peulen, Heike; Rossi, Maddalena M G; Belderbos, José S A; Sonke, Jan-Jakob
2016-03-01
Determination of a dose-effect relation for rib fractures in a large patient group has been limited by the time consuming manual delineation of ribs. Automatic segmentation could facilitate such an analysis. We determine the accuracy of automatic rib segmentation in the context of normal tissue complication probability modeling (NTCP). Forty-one patients with stage I/II non-small cell lung cancer treated with SBRT to 54 Gy in 3 fractions were selected. Using the 4DCT derived mid-ventilation planning CT, all ribs were manually contoured and automatically segmented. Accuracy of segmentation was assessed using volumetric, shape and dosimetric measures. Manual and automatic dosimetric parameters Dx and EUD were tested for equivalence using the Two One-Sided T-test (TOST), and assessed for agreement using Bland-Altman analysis. NTCP models based on manual and automatic segmentation were compared. Automatic segmentation was comparable with the manual delineation in radial direction, but larger near the costal cartilage and vertebrae. Manual and automatic Dx and EUD were significantly equivalent. The Bland-Altman analysis showed good agreement. The two NTCP models were very similar. Automatic rib segmentation was significantly equivalent to manual delineation and can be used for NTCP modeling in a large patient group. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Frueh, B. Christopher; Monnier, Jeannine; Grubaugh, Anouk L.; Elhai, Jon D.; Yim, Eunsil; Knapp, Rebecca
2007-01-01
Using secondary analyses from a randomized trial comparing the effectiveness of manualized cognitive-behavioral therapy for posttraumatic stress disorder, we compared ratings of therapist competency and adherence between two service delivery modes: telepsychiatry (TP) and same room (SR). Patients were 38 male treatment-seeking veterans recruited…
de-Miguel-Valtierra, Lorena; Salom-Moreno, Jaime; Fernández-de-Las-Peñas, César; Cleland, Joshua A; Arias-Buría, José L
2018-05-16
This randomized clinical trial compared the effects of adding US-guided percutaneous electrolysis into a program consisting of manual therapy and exercise on pain, related-disability, function and pressure sensitivity in subacromial pain syndrome. Fifty patients with subacromial pain syndrome were randomized into manual therapy and exercise or percutaneous electrolysis group. All patients received the same manual therapy and exercise program, one session per week for 5 consecutive weeks. Patients assigned to the electrolysis group also received the application of percutaneous electrolysis at each session. The primary outcome was Disabilities of the Arm, Shoulder and Hand (DASH). Secondary outcomes included pain, function (Shoulder Pain and Disability Index-SPADI) pressure pain thresholds (PPTs) and Global Rating of Change (GROC). They were assessed at baseline, post-treatment, and 3, and 6 months after treatment. Both groups showed similar improvements in the primary outcome (DASH) at all follow-ups (P=0.051). Subjects receiving manual therapy, exercise, and percutaneous electrolysis showed significantly greater changes in shoulder pain (P<0.001) and SPADI (P<0.001) than those receiving manual therapy and exercise alone at all follow-ups. Effect sizes were large (SMD>0.91) for shoulder pain and function at 3 and 6 months in favour of the percutaneous electrolysis group. No between-groups differences in PPT were found. The current clinical trial found that the inclusion of US-guided percutaneous electrolysis in combination with manual therapy and exercise resulted in no significant differences for related-disability (DASH) than the application of manual therapy and exercise alone in patients with subacromial pain syndrome. Nevertheless, differences were reported for some secondary outcomes such as shoulder pain and function (SPADI). Whether or not these effects are reliable should be addressed in future studies Perspective This study found that the inclusion of US-guided percutaneous electrolysis into a manual therapy and exercise program resulted in no significant differences for disability and pressure pain sensitivity than the application of manual therapy and exercise alone in patients with subacromial pain syndrome. Copyright © 2018. Published by Elsevier Inc.
Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro
2013-02-01
The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.
Finck, R H; Davis, R J; Teng, S; Goldfinger, D; Ziman, A F; Lu, Q; Yuan, S
2011-01-01
IgG antibodies coating red blood cells (RBCs) can be removed by elution procedures and their specificity determined by antibody identification studies. Although such testing is traditionally performed using the tube agglutination assay, prior studies have shown that the gel microcolumn (GMC) assay may also be used with comparable results. The purpose of this study was to compare an automated solid-phase red cell adherence (SPRCA) system with a GMC assay for the detection of antibodies eluted from RBCs. Acid eluates from 51 peripheral blood (PB) and 7 cord blood (CB) samples were evaluated by both an automated SPRCA instrument and a manual GMC assay. The concordance rate between the two systems for peripheral RBC samples was 88.2 percent (45 of 51), including cases with alloantibodies (n = 8), warm autoantibodies (n = 12), antibodies with no identifiable specificity (n = 2), and negative results (n = 23). There were six discordant cases, of which four had alloantibodies (including anti-Jka, -E, and -e) demonstrable by the SPRCA system only. In the remaining 2 cases, anti-Fya and antibodies with no identifiable specificity were demonstrable by the GMC assay only. All seven CB specimens produced concordant results, showing anti-A (n = 3), -B (n = 1), maternal anti-Jka (n = 2), or a negative result (n = 1). Automated SPRCA technology has a performance that is comparable with that of a manual GMC assay for identifying antibodies eluted from PB and CB RBCs.
Manual therapy in osteoarthritis of the hip: outcome in subgroups of patients.
Hoeksma, H L; Dekker, J; Ronday, H K; Breedveld, F C; Van den Ende, C H M
2005-04-01
To investigate whether manual therapy has particular benefit in subgroups of patients defined on the basis of hip function, range of joint motion, pain and radiological deterioration. The study was performed in the out-patient clinic of physical therapy of a large hospital. Data on 109 patients with OA of the hip (clinical ACR criteria) participating in a randomized clinical trial on the effects of manual therapy were used. The outcomes for hip function (Harris hip score), range of joint motion (ROM) and pain (VAS) were compared for specific subgroups. Subgroups were assigned by the median split method. The interaction effect between subgroup and treatment was tested using multiple regression analysis. No differences were observed in the effect of manual therapy in specific subgroups of patients defined on the basis of baseline levels of hip function, pain and ROM. On the basis of radiological grading of osteoarthritis (OA), we found that patients with severe radiological grading of OA had significantly worse outcome on ROM as a result of manual therapy than patients with mild or moderate radiological grading of OA. A significant interaction effect was found for only 1 out of 12 hypotheses investigated. Therefore, we conclude that there is no evidence for the particular benefit of manual therapy in subgroups of patients.
Murthy, Prashanth Sadashiva; Shaik, Naseemoon; Deshmukh, Seema; Girish, M S
2018-01-01
Establishing good hygiene habits are valuable for present and future oral health. Below 6 years, tooth brushing should be performed by parents, as increasing dexterity and cognition may permit supervised brushing until the child is capable of independent brushing. The aim of the present study was to evaluate the effectiveness of modified oral irrigation device in children in terms of plaque control and to compare the effectiveness of plaque control with manual brushing with the modified oral irrigation device in children. A randomized clinical trial was performed on 12 subjects who were allocated to the two study groups. After obtaining the consent, the control group was instructed tooth brushing with regular pediatric commercially available toothbrush and the intervention group with modified oral irrigation device. Plaque scores in both groups were assessed pre- and post-brushing using modified navy plaque index. The data were subjected to Descriptive statistics and Paired t -test using SPSS version 22. Intragroup comparison of mean difference of plaque score in control group and intervention group pre- and post-brushing was statistically significant. Intergroup comparison of manual brushing group with modified oral irrigation group shows P < 0.05 was statistically significant. Within the limitation of the present study, it has been found novel pediatric oral hygiene need Station is more effective than manual brushing since it combined the effect of brushing, flossing (water floss), and rinsing in children simultaneously and at the same time did not demand any special motor skill.
Kloefkorn, Heidi E.; Pettengill, Travis R.; Turner, Sara M. F.; Streeter, Kristi A.; Gonzalez-Rothi, Elisa J.; Fuller, David D.; Allen, Kyle D.
2016-01-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns. PMID:27554674
Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D
2017-03-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.
Comparison of manual and automatic MR-CT registration for radiotherapy of prostate cancer.
Korsager, Anne Sofie; Carl, Jesper; Riis Østergaard, Lasse
2016-05-08
In image-guided radiotherapy (IGRT) of prostate cancer, delineation of the clini-cal target volume (CTV) often relies on magnetic resonance (MR) because of its good soft-tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR-CT registration of the prostate has previously been developed using a voxel property-based registration as an alternative to a manual landmark-based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni-Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration.
Validation of Computerized Automatic Calculation of the Sequential Organ Failure Assessment Score
Harrison, Andrew M.; Pickering, Brian W.; Herasevich, Vitaly
2013-01-01
Purpose. To validate the use of a computer program for the automatic calculation of the sequential organ failure assessment (SOFA) score, as compared to the gold standard of manual chart review. Materials and Methods. Adult admissions (age > 18 years) to the medical ICU with a length of stay greater than 24 hours were studied in the setting of an academic tertiary referral center. A retrospective cross-sectional analysis was performed using a derivation cohort to compare automatic calculation of the SOFA score to the gold standard of manual chart review. After critical appraisal of sources of disagreement, another analysis was performed using an independent validation cohort. Then, a prospective observational analysis was performed using an implementation of this computer program in AWARE Dashboard, which is an existing real-time patient EMR system for use in the ICU. Results. Good agreement between the manual and automatic SOFA calculations was observed for both the derivation (N=94) and validation (N=268) cohorts: 0.02 ± 2.33 and 0.29 ± 1.75 points, respectively. These results were validated in AWARE (N=60). Conclusion. This EMR-based automatic tool accurately calculates SOFA scores and can facilitate ICU decisions without the need for manual data collection. This tool can also be employed in a real-time electronic environment. PMID:23936639
Schmidt, Jürgen; Laarousi, Rihab; Stolzmann, Wolfgang; Karrer-Gauß, Katja
2018-06-01
In this article, we examine the performance of different eye blink detection algorithms under various constraints. The goal of the present study was to evaluate the performance of an electrooculogram- and camera-based blink detection process in both manually and conditionally automated driving phases. A further comparison between alert and drowsy drivers was performed in order to evaluate the impact of drowsiness on the performance of blink detection algorithms in both driving modes. Data snippets from 14 monotonous manually driven sessions (mean 2 h 46 min) and 16 monotonous conditionally automated driven sessions (mean 2 h 45 min) were used. In addition to comparing two data-sampling frequencies for the electrooculogram measures (50 vs. 25 Hz) and four different signal-processing algorithms for the camera videos, we compared the blink detection performance of 24 reference groups. The analysis of the videos was based on very detailed definitions of eyelid closure events. The correct detection rates for the alert and manual driving phases (maximum 94%) decreased significantly in the drowsy (minus 2% or more) and conditionally automated (minus 9% or more) phases. Blinking behavior is therefore significantly impacted by drowsiness as well as by automated driving, resulting in less accurate blink detection.
Better care for the dying. Hawaii healthcare system develops a manual for end-of-life care.
Kalua, P M; Tan, S Y; Bacon, J G
1999-01-01
In early 1996, as it became clear that Americans were becoming increasingly concerned about end-of-life care, the leaders of St. Francis Healthcare System (SFHS), Honolulu, convened a meeting at which local people--community and parish representatives as well as healthcare professionals--discussed the matter. The meeting's participants identified 10 issues as essential in end-of-life care: decision making, pain management and comfort care, pastoral and spiritual care, psychosocial care, hospice and home care, cardiopulmonary resuscitation, futility, withholding and withdrawing treatment, artificial nutrition and hydration, physician-assisted suicide and euthanasia. The participants then divided themselves into 10 teams, each of which spent six months studying one of the identified essential issues. In each case, the team reviewed the relevant SFHS policies and procedures and compared them with national standards. The team also interviewed staff members about the policies and procedures, comparing the written versions with actual practices. Each team then wrote a chapter on its assigned issue, after which a core committee wove the chapters into an end-of-life care manual for SFHS. The manual was published in June 1997. The system's leaders currently use the manual to educate staff members in good end-of-life care.
Automated surface quality inspection with ARGOS: a case study
NASA Astrophysics Data System (ADS)
Kiefhaber, Daniel; Etzold, Fabian; Warken, Arno F.; Asfour, Jean-Michel
2017-06-01
The commercial availability of automated inspection systems for optical surfaces specified according to ISO 10110-7 promises unsupervised and automated quality control with reproducible results. In this study, the classification results of the ARGOS inspection system are compared to the decisions by well-trained inspectors based on manual-visual inspection. Both are found to agree in 93.6% of the studied cases. Exemplary cases with differing results are studied, and shown to be partly caused by shortcomings of the ISO 10110-7 standard, which was written for the industry standard manual-visual inspection. Applying it to high resolution images of the whole surface of objective machine vision systems brings with it a few challenges which are discussed.
Wright, Alexis A; Abbott, J Haxby; Baxter, Dave; Cook, Chad
2010-09-01
THE OBJECTIVES OF THIS STUDY WERE TO: (1) determine the association of a within-session finding after traction of the hip with self-report of well-being, pain, and self-report of function at 9 weeks; and (2) to determine if the interactions between the within-session finding and the outcome measure are different between groups of patients with hip OA who receive and who do not receive manual therapy. Data were retrospectively analysed in 70 subjects who were part of a randomized control trial. Correlation analyses of within-session findings from the initial visit after traction of a concordantly painful hip were compared to self-report measures for function, pain, and well-being at 9 weeks. A comparison of slope coefficients between manual therapy and non-manual therapy groups was performed to determine the interactive aspects of the within-session finding. Although the correlations for the manual therapy group were higher than for the supervised neglect group, none of the correlational analyses for both groups was strong or significant. Significant differences in the slope coefficients for well-being and pain were found, suggesting that the interactions between the within-session findings and the targeted outcomes were different in the manual therapy group versus supervised neglect group. These findings suggest that within-session findings during the initial evaluation are not strongly related to a positive outcome after manual therapy, although the interaction of the finding of a within-session change and the use of manual therapy is more compelling than the finding in a sample of patients who did not receive manual therapy.
Brink, Carsten; Lorenzen, Ebbe L; Krogh, Simon Long; Westberg, Jonas; Berg, Martin; Jensen, Ingelise; Thomsen, Mette Skovhus; Yates, Esben Svitzer; Offersen, Birgitte Vrou
2018-01-01
The current study evaluates the data quality achievable using a national data bank for reporting radiotherapy parameters relative to the classical manual reporting method of selected parameters. The data comparison is based on 1522 Danish patients of the DBCG hypo trial with data stored in the Danish national radiotherapy data bank. In line with standard DBCG trial practice selected parameters were also reported manually to the DBCG database. Categorical variables are compared using contingency tables, and comparison of continuous parameters is presented in scatter plots. For categorical variables 25 differences between the data bank and manual values were located. Of these 23 were related to mistakes in the manual reported value whilst the remaining two were a wrong classification in the data bank. The wrong classification in the data bank was related to lack of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients.
Adnan, Mehnaz; Peterkin, Donald; Lopez, Liza; Mackereth, Graham
2017-02-01
Electronic reporting of Influenza-like illness (eILI) from primary care was implemented and evaluated in three general medical practices in New Zealand during May to September 2015. To measure the uptake of eILI and to identify the system's strength and limitations. Analysis of transactional data from the eILI system; comparative study of influenza-like illness cases reported using manual methods and eILI; questionnaire administered to clinical and operational stakeholders. Over the study period 66% of total ILI cases were reported using eILI. Reporting timeliness improved significantly compared to manual reporting with an average of 24 minutes from submission by the clinician to processing in the national database. Users found the system to be user-friendly. eILI assists clinicians to report ILI cases to public health authorities within a stipulated time period and is associated with faster, more reliable and improved information transfer.
Jenkins, Wendy; Souza, Sonia; Ward, Marilyn; Defenbaugh, Jodi; Milleman, Kimberly R; Milleman, Jeffery L
2017-03-01
To assess the effect of the Philips Sonicare FlexCare Platinum with Premium plaque control brush head on gingival inflammation, bleeding, and supragingival plaque reduction following a six-week period of home use compared to a manual toothbrush. This was a randomized, single-blind, parallel-design clinical trial. Subjects included in the study were routine manual toothbrush users who were generally healthy non-smokers, aged 18-65 years, with mild to moderate gingivitis. Subjects with advanced periodontal disease, excessive gingival recession, and heavy deposits of calculus or rampant decay were excluded from the study. Eligible participants were dispensed either Philips Sonicare FlexCare Platinum with Premium plaque control brush head (PC), or an ADA Reference manual toothbrush (MTB) for twice-daily home oral hygiene procedures for six weeks. Efficacy measures included the Lobene and Soparker Modification of Quigley and Hein Plaque Index (MPI), the Modified Gingival Index (MGI), and Gingival Bleeding Index (GBI). Safety was evaluated by oral examination and subject report. Efficacy and safety were assessed at Baseline, and at two and six weeks following product home use. Of 154 subjects randomized, 143 subjects completed the study. For the primary endpoint, MGI at Week 2, statistically significantly larger reductions in MGI were observed for PC versus MTB, p < 0.0001. The adjusted mean reduction and standard error estimates (SE) for MGI, expressed as percent reduction versus Baseline to Week 2, were 41.73% (2.00%) for PC and 7.38% (2.02%) for MTB. Statistically significant differences were also observed for MPI and GBI at Week 2, and for all metrics at Week 6. Philips Sonicare FlexCare Platinum with Premium plaque control brush head statistically significantly reduces gingival inflammation, gingival bleeding, and plaque following two and six weeks of home use, compared to manual tooth brushing alone.
Walker, Jochen; Mertens, Ulf Kai; Schmidt, Carsten Oliver; Chenot, Jean-François
2017-01-01
Spinal manual therapy (SMT) is a popular treatment option for low back pain (LBP). The aim of our analysis was to evaluate the effects of manual therapy delivered by general practitioners and ambulatory orthopedic surgeons in routine care on follow up consultations, sick leave, health service utilization and costs for acute LBP compared to matched patients not receiving manual therapy. This is a propensity score matched cohort study based on health claims data. We identified a total of 113.652 adult patients with acute LBP and no coded red flags of whom 21.021 (18%) received SMT by physicians. In the final analysis 17.965 patients in each group could be matched. Balance on patients' coded characteristics, comorbidity and prior health service utilization was achieved. The provision of SMT for acute LBP had no relevant impact on follow up visits and days of sick leave for LBP in the index billing period and the following year. SMT was associated with a higher proportion of imaging studies for LBP (30.6% vs. 23%, SMD: 0.164 [95% CI 0.143-0.185]). SMT did not lead to meaningful savings by replacing other health services for LBP. SMT for acute non-specific LBP in routine care was not clinically meaningful effective to reduce sick leave and reconsultation rates compared to no SMT and did not lead to meaningful savings by replacing other health services from the perspective of health insurance. This does not imply that SMT is ineffective but might reflect a problem with selection of suitable patients and the quality and quantity of SMT in routine care. National Manual Medicine societies should state clearly that imaging is not routinely needed prior to SMT in patients with low suspicion of presence of red flags and monitor the quality of provided services.
Arnal, Jean-Michel; Garnero, Aude; Novotni, Dominik; Corno, Gaëlle; Donati, Stéphane-Yannis; Demory, Didier; Quintana, Gabrielle; Ducros, Laurent; Laubscher, Thomas; Durand-Gasselin, Jacques
2018-01-01
There is an equipoise regarding closed-loop ventilation modes and the ability to reduce workload for providers. On one hand some settings are managed by the ventilator but on another hand the automatic mode introduces new settings for the user. This randomized controlled trial compared the number of manual ventilator setting changes between a full closed loop ventilation and oxygenation mode (INTELLiVENT-ASV®) and conventional ventilation modes (volume assist control and pressure support) in Intensive Care Unit (ICU) patients. The secondary endpoints were to compare the number of arterial blood gas analysis, the sedation dose and the user acceptance. Sixty subjects with an expected duration of mechanical ventilation of at least 48 hours were randomized to be ventilated using INTELLiVENT-ASV® or conventional modes with a protocolized weaning. All manual ventilator setting changes were recorded continuously from inclusion to successful extubation or death. Arterial blood gases were performed upon decision of the clinician in charge. User acceptance score was assessed for nurses and physicians once daily using a Likert Scale. The number of manual ventilator setting changes per 24 h-period per subject was lower in INTELLiVENT-ASV® as compared to conventional ventilation group (5 [4-7] versus 10 [7-17]) manuals settings per subject per day [P<0.001]). The number of arterial blood gas analysis and the sedation doses were not significantly different between the groups. Nurses and physicians reported that INTELLiVENT-ASV® was significantly easier to use as compared to conventional ventilation (P<0.001 for nurses and P<0.01 for physicians). For mechanically ventilated ICU patients, INTELLiVENT-ASV® significantly reduces the number of manual ventilator setting changes with the same number of arterial blood gas analysis and sedation dose, and is easier to use for the caregivers as compared to conventional ventilation modes.
Mansberger, Steven L; Menda, Shivali A; Fortune, Brad A; Gardiner, Stuart K; Demirel, Shaban
2017-02-01
To characterize the error of optical coherence tomography (OCT) measurements of retinal nerve fiber layer (RNFL) thickness when using automated retinal layer segmentation algorithms without manual refinement. Cross-sectional study. This study was set in a glaucoma clinical practice, and the dataset included 3490 scans from 412 eyes of 213 individuals with a diagnosis of glaucoma or glaucoma suspect. We used spectral domain OCT (Spectralis) to measure RNFL thickness in a 6-degree peripapillary circle, and exported the native "automated segmentation only" results. In addition, we exported the results after "manual refinement" to correct errors in the automated segmentation of the anterior (internal limiting membrane) and the posterior boundary of the RNFL. Our outcome measures included differences in RNFL thickness and glaucoma classification (i.e., normal, borderline, or outside normal limits) between scans with automated segmentation only and scans using manual refinement. Automated segmentation only resulted in a thinner global RNFL thickness (1.6 μm thinner, P < .001) when compared to manual refinement. When adjusted by operator, a multivariate model showed increased differences with decreasing RNFL thickness (P < .001), decreasing scan quality (P < .001), and increasing age (P < .03). Manual refinement changed 298 of 3486 (8.5%) of scans to a different global glaucoma classification, wherein 146 of 617 (23.7%) of borderline classifications became normal. Superior and inferior temporal clock hours had the largest differences. Automated segmentation without manual refinement resulted in reduced global RNFL thickness and overestimated the classification of glaucoma. Differences increased in eyes with a thinner RNFL thickness, older age, and decreased scan quality. Operators should inspect and manually refine OCT retinal layer segmentation when assessing RNFL thickness in the management of patients with glaucoma. Copyright © 2016 Elsevier Inc. All rights reserved.
Multi-Modal Glioblastoma Segmentation: Man versus Machine
Pica, Alessia; Schucht, Philippe; Beck, Jürgen; Verma, Rajeev Kumar; Slotboom, Johannes; Reyes, Mauricio; Wiest, Roland
2014-01-01
Background and Purpose Reproducible segmentation of brain tumors on magnetic resonance images is an important clinical need. This study was designed to evaluate the reliability of a novel fully automated segmentation tool for brain tumor image analysis in comparison to manually defined tumor segmentations. Methods We prospectively evaluated preoperative MR Images from 25 glioblastoma patients. Two independent expert raters performed manual segmentations. Automatic segmentations were performed using the Brain Tumor Image Analysis software (BraTumIA). In order to study the different tumor compartments, the complete tumor volume TV (enhancing part plus non-enhancing part plus necrotic core of the tumor), the TV+ (TV plus edema) and the contrast enhancing tumor volume CETV were identified. We quantified the overlap between manual and automated segmentation by calculation of diameter measurements as well as the Dice coefficients, the positive predictive values, sensitivity, relative volume error and absolute volume error. Results Comparison of automated versus manual extraction of 2-dimensional diameter measurements showed no significant difference (p = 0.29). Comparison of automated versus manual segmentation of volumetric segmentations showed significant differences for TV+ and TV (p<0.05) but no significant differences for CETV (p>0.05) with regard to the Dice overlap coefficients. Spearman's rank correlation coefficients (ρ) of TV+, TV and CETV showed highly significant correlations between automatic and manual segmentations. Tumor localization did not influence the accuracy of segmentation. Conclusions In summary, we demonstrated that BraTumIA supports radiologists and clinicians by providing accurate measures of cross-sectional diameter-based tumor extensions. The automated volume measurements were comparable to manual tumor delineation for CETV tumor volumes, and outperformed inter-rater variability for overlap and sensitivity. PMID:24804720
Madder, Ryan D; VanOosterhout, Stacie; Mulder, Abbey; Elmore, Matthew; Campbell, Jessica; Borgman, Andrew; Parker, Jessica; Wohns, David
Reports of left-sided brain malignancies among interventional cardiologists have heightened concerns regarding physician radiation exposure. This study evaluated the impact of a suspended lead suit and robotic system on physician radiation exposure during percutaneous coronary intervention (PCI). Real-time radiation exposure data were prospectively collected from dosimeters worn by operating physicians at the head- and chest-level during consecutive PCI cases. Exposures were compared in three study groups: 1) manual PCI performed with traditional lead apparel; 2) manual PCI performed using suspended lead; and 3) robotic PCI performed in combination with suspended lead. Among 336 cases (86.6% manual, 13.4% robotic) performed over 30weeks, use of suspended lead during manual PCI was associated with significantly less radiation exposure to the chest and head of operating physicians than traditional lead apparel (chest: 0.0 [0.1] μSv vs 0.4 [4.0] μSv, p<0.001; head: 0.5 [1.9] μSv vs 14.9 [51.5] μSv, p<0.001). Chest-level radiation exposure during robotic PCI performed in combination with suspended lead was 0.0 [0.0] μSv, which was significantly less chest exposure than manual PCI performed with traditional lead (p<0.001) or suspended lead (p=0.046). In robotic PCI the median head-level exposure was 0.1 [0.2] μSv, which was 99.3% less than manual PCI performed with traditional lead (p<0.001) and 80.0% less than manual PCI performed with suspended lead (p<0.001). Utilization of suspended lead and robotics were observed to result in significantly less radiation exposure to the chest and head of operating physicians during PCI. Copyright © 2016 Elsevier Inc. All rights reserved.
Gardner, William; Morton, Suzanne; Byron, Sepheen C; Tinoco, Aldo; Canan, Benjamin D; Leonhart, Karen; Kong, Vivian; Scholle, Sarah Hudson
2014-01-01
Objective To determine whether quality measures based on computer-extracted EHR data can reproduce findings based on data manually extracted by reviewers. Data Sources We studied 12 measures of care indicated for adolescent well-care visits for 597 patients in three pediatric health systems. Study Design Observational study. Data Collection/Extraction Methods Manual reviewers collected quality data from the EHR. Site personnel programmed their EHR systems to extract the same data from structured fields in the EHR according to national health IT standards. Principal Findings Overall performance measured via computer-extracted data was 21.9 percent, compared with 53.2 percent for manual data. Agreement measures were high for immunizations. Otherwise, agreement between computer extraction and manual review was modest (Kappa = 0.36) because computer-extracted data frequently missed care events (sensitivity = 39.5 percent). Measure validity varied by health care domain and setting. A limitation of our findings is that we studied only three domains and three sites. Conclusions The accuracy of computer-extracted EHR quality reporting depends on the use of structured data fields, with the highest agreement found for measures and in the setting that had the greatest concentration of structured fields. We need to improve documentation of care, data extraction, and adaptation of EHR systems to practice workflow. PMID:24471935
Sharma, Naresh C; Qaqish, Jimmy G; He, Tao; Walters, Patricia A; Grender, Julie M; Biesbrock, Aaron R
2010-12-01
To compare the safety and efficacy of a novel sonic power toothbrush and a manual toothbrush in the reduction of gingivitis and plaque over a 4-week period. This study employed a randomized two treatment, examiner-blinded, parallel group design. Subjects with evidence of gingivitis were randomly assigned to 4 weeks' twice daily home use of either the Oral-B Pulsonic sonic toothbrush or an ADA reference manual toothbrush. At baseline (Visit 1) and again after product use at Week 4, subjects received gingivitis evaluations with the Modified Gingival Index (MGI) and Gingival Bleeding Index (GBI) examinations, followed by plaque assessment using the Rustogi Modified Navy Plaque Index (RMNPI). For 12 hours before both visits, subjects abstained from all oral hygiene, and ceased eating, drinking and smoking 4 hours prior. Both brushes significantly reduced gingivitis, gingival bleeding and plaque compared with baseline, and were well-tolerated by the 129 subjects completing the study. The sonic toothbrush was statistically significantly (P < 0.0001) more effective than the manual brush, with greater relative mean reductions in MGI, GBI and RMNPI of 11.9%, 62.3% and 46.5%, respectively.
The second Chicago televised smoking cessation program: a 24-month follow-up.
Warnecke, R B; Langenberg, P; Wong, S C; Flay, B R; Cook, T D
1992-01-01
OBJECTIVES. As smoking decreases in the population, the remaining smoking population will change, and cessation initiatives will have to incorporate strategies designed for these smokers. METHODS. To study patterns of response to a cessation intervention composed of 20 televised segments and the American Lung Association Freedom from Smoking in 20 Days manual, this study compared cessation rates over 24 months in a cohort of smokers who registered for a cessation program with those in a cohort selected from the smoking population at large. RESULTS. At post intervention, multiple point prevalence of cessation among participants, adjusted for baseline smoking, was 14% among registrants and 6% in the population; at 24 months the adjusted rates were 6% and 2%, respectively. Heavy smokers benefited more than light smokers, and there was a consistent dose-response relationship between extent of exposure to the intervention and cessation. CONCLUSION. The effects of the intervention were strongest for those who read the manual and watched the programs daily. Manual use was important, and those who did not read it did not appear to benefit. Compared to the population and given full participation, heavy smokers benefited more than lighter smokers. PMID:1585964
Louw, Adriaan; Farrell, Kevin; Landers, Merrill; Barclay, Martin; Goodman, Elise; Gillund, Jordan; McCaffrey, Sara; Timmerman, Laura
2017-12-01
To determine if a neuroplasticity educational explanation for a manual therapy technique will produce a different outcome compared to a traditional mechanical explanation. Sixty-two patients with chronic low back pain (CLBP) were recruited for the study. Following consent, demographic data were obtained as well as pain ratings for low back pain (LBP) and leg pain (Numeric Pain Rating Scale), disability (Oswestry Disability Index), fear-avoidance (Fear-Avoidance-Beliefs Questionnaire), forward flexion (fingertips-to-floor), and straight leg raise (SLR) (inclinometer). Patients were then randomly allocated to receive one of two explanations (neuroplasticity or mechanical), a manual therapy technique to their lumbar spine, followed by post-intervention measurements of LBP, leg pain, forward flexion, and SLR. Sixty-two patients (female 35 [56.5%]), with a mean age of 60.1 years and mean duration of 9.26 years of CLBP participated in the study. There were no statistically significant interactions for LBP ( p = .325), leg pain ( p = .172), and trunk flexion ( p = .818) between the groups, but SLR showed a significant difference in favor of the neuroplasticity explanation ( p = .041). Additionally, the neuroplasticity group were 7.2 times (95% confidence interval = 1.8-28.6) more likely to improve beyond the MDC on the SLR than participants in the mechanical group. The results of this study show that a neuroplasticity explanation, compared to a traditional biomechanical explanation, resulted in a measureable difference in SLR in patients with CLBP when receiving manual therapy. Future studies need to explore if the increase in SLR correlated to changes in cortical maps of the low back.
Russ, Daniel E.; Ho, Kwan-Yuet; Colt, Joanne S.; Armenti, Karla R.; Baris, Dalsu; Chow, Wong-Ho; Davis, Faith; Johnson, Alison; Purdue, Mark P.; Karagas, Margaret R.; Schwartz, Kendra; Schwenn, Molly; Silverman, Debra T.; Johnson, Calvin A.; Friesen, Melissa C.
2016-01-01
Background Mapping job titles to standardized occupation classification (SOC) codes is an important step in identifying occupational risk factors in epidemiologic studies. Because manual coding is time-consuming and has moderate reliability, we developed an algorithm called SOCcer (Standardized Occupation Coding for Computer-assisted Epidemiologic Research) to assign SOC-2010 codes based on free-text job description components. Methods Job title and task-based classifiers were developed by comparing job descriptions to multiple sources linking job and task descriptions to SOC codes. An industry-based classifier was developed based on the SOC prevalence within an industry. These classifiers were used in a logistic model trained using 14,983 jobs with expert-assigned SOC codes to obtain empirical weights for an algorithm that scored each SOC/job description. We assigned the highest scoring SOC code to each job. SOCcer was validated in two occupational data sources by comparing SOC codes obtained from SOCcer to expert assigned SOC codes and lead exposure estimates obtained by linking SOC codes to a job-exposure matrix. Results For 11,991 case-control study jobs, SOCcer-assigned codes agreed with 44.5% and 76.3% of manually assigned codes at the 6- and 2-digit level, respectively. Agreement increased with the score, providing a mechanism to identify assignments needing review. Good agreement was observed between lead estimates based on SOCcer and manual SOC assignments (kappa: 0.6–0.8). Poorer performance was observed for inspection job descriptions, which included abbreviations and worksite-specific terminology. Conclusions Although some manual coding will remain necessary, using SOCcer may improve the efficiency of incorporating occupation into large-scale epidemiologic studies. PMID:27102331
Hartmann, Luise; Stephenson, Christine F; Verkamp, Stephanie R; Johnson, Krystal R; Burnworth, Bettina; Hammock, Kelle; Brodersen, Lisa Eidenschink; de Baca, Monica E; Wells, Denise A; Loken, Michael R; Zehentner, Barbara K
2014-12-01
Array comparative genomic hybridization (aCGH) has become a powerful tool for analyzing hematopoietic neoplasms and identifying genome-wide copy number changes in a single assay. aCGH also has superior resolution compared with fluorescence in situ hybridization (FISH) or conventional cytogenetics. Integration of single nucleotide polymorphism (SNP) probes with microarray analysis allows additional identification of acquired uniparental disomy, a copy neutral aberration with known potential to contribute to tumor pathogenesis. However, a limitation of microarray analysis has been the inability to detect clonal heterogeneity in a sample. This study comprised 16 samples (acute myeloid leukemia, myelodysplastic syndrome, chronic lymphocytic leukemia, plasma cell neoplasm) with complex cytogenetic features and evidence of clonal evolution. We used an integrated manual peak reassignment approach combining analysis of aCGH and SNP microarray data for characterization of subclonal abnormalities. We compared array findings with results obtained from conventional cytogenetic and FISH studies. Clonal heterogeneity was detected in 13 of 16 samples by microarray on the basis of log2 values. Use of the manual peak reassignment analysis approach improved resolution of the sample's clonal composition and genetic heterogeneity in 10 of 13 (77%) patients. Moreover, in 3 patients, clonal disease progression was revealed by array analysis that was not evident by cytogenetic or FISH studies. Genetic abnormalities originating from separate clonal subpopulations can be identified and further characterized by combining aCGH and SNP hybridization results from 1 integrated microarray chip by use of the manual peak reassignment technique. Its clinical utility in comparison to conventional cytogenetic or FISH studies is demonstrated. © 2014 American Association for Clinical Chemistry.
Sjögren, Karin; Lundberg, Ann-Britt; Birkhed, Dowen; Dudgeon, Douglas J; Johnson, Matthew R
2004-01-01
To determine differences in interproximal plaque mass and fluoride retention with different modes of toothbrushing and flossing. Forty-seven subjects in good health used four treatments in a four-period, randomized, crossover design: 1) manual brushing only; 2) manual brushing and daily flossing; 3) electric brushing using a rotational oscillation toothbrush; and 4) electric brushing using a sonic toothbrush. Subjects used a standard sodium fluoride dentifrice during the eight-day experimental periods and a fluoride-free dentifrice during the seven-day washout periods between treatments. Interproximal plaque samples were taken on Day 1 and on Day 8, weighed, and analyzed for fluoride content. The amount of interproximal plaque was lowest with sonic brushing, which left 43-65% less plaque than all other treatments. Manual brushing and flossing yielded less plaque than manual brushing alone and rotational oscillation brushing. Differences were statistically significant (p < 0.05) for treatment; there was no time effect on plaque mass. For fluoride retention, at Day 1 sonic brushing gave at least 54% more fluoride in the interproximal plaque than all other treatments, which was significant. All treatments demonstrated a significant increase in fluoride concentration with time except manual brushing and flossing, which showed a significant decrease. At Day 8, the fluoride concentration was significantly higher for sonic brushing than for manual brushing or rotational oscillation brushing by over 40%, and all treatments exhibited significantly greater fluoride than the manual brushing and flossing combination. The mode of toothbrushing may impact the amount of plaque retained interproximally and its fluoride concentration.
Can Family-Based Treatment of Anorexia Nervosa Be Manualized?
Lock, James; Le Grange, Daniel
2001-01-01
The authors report on the development of a manual for treating adolescents with anorexia nervosa modeled on a family-based intervention originating at the Maudsley Hospital in London. The manual provides the first detailed account of a clinical approach shown to be consistently efficacious in randomized clinical trials for this disorder. Manualized family therapy appears to be acceptable to therapists, patients, and families. Preliminary outcomes are comparable to what would be expected in clinically supervised sessions. These results suggest that through the use of this manual a valuable treatment approach can now be tested more broadly in controlled and uncontrolled settings. PMID:11696652
Dysli, Chantal; Enzmann, Volker; Sznitman, Raphael; Zinkernagel, Martin S.
2015-01-01
Purpose Quantification of retinal layers using automated segmentation of optical coherence tomography (OCT) images allows for longitudinal studies of retinal and neurological disorders in mice. The purpose of this study was to compare the performance of automated retinal layer segmentation algorithms with data from manual segmentation in mice using the Spectralis OCT. Methods Spectral domain OCT images from 55 mice from three different mouse strains were analyzed in total. The OCT scans from 22 C57Bl/6, 22 BALBc, and 11 C3A.Cg-Pde6b+Prph2Rd2/J mice were automatically segmented using three commercially available automated retinal segmentation algorithms and compared to manual segmentation. Results Fully automated segmentation performed well in mice and showed coefficients of variation (CV) of below 5% for the total retinal volume. However, all three automated segmentation algorithms yielded much thicker total retinal thickness values compared to manual segmentation data (P < 0.0001) due to segmentation errors in the basement membrane. Conclusions Whereas the automated retinal segmentation algorithms performed well for the inner layers, the retinal pigmentation epithelium (RPE) was delineated within the sclera, leading to consistently thicker measurements of the photoreceptor layer and the total retina. Translational Relevance The introduction of spectral domain OCT allows for accurate imaging of the mouse retina. Exact quantification of retinal layer thicknesses in mice is important to study layers of interest under various pathological conditions. PMID:26336634
Automatic sentence extraction for the detection of scientific paper relations
NASA Astrophysics Data System (ADS)
Sibaroni, Y.; Prasetiyowati, S. S.; Miftachudin, M.
2018-03-01
The relations between scientific papers are very useful for researchers to see the interconnection between scientific papers quickly. By observing the inter-article relationships, researchers can identify, among others, the weaknesses of existing research, performance improvements achieved to date, and tools or data typically used in research in specific fields. So far, methods that have been developed to detect paper relations include machine learning and rule-based methods. However, a problem still arises in the process of sentence extraction from scientific paper documents, which is still done manually. This manual process causes the detection of scientific paper relations longer and inefficient. To overcome this problem, this study performs an automatic sentences extraction while the paper relations are identified based on the citation sentence. The performance of the built system is then compared with that of the manual extraction system. The analysis results suggested that the automatic sentence extraction indicates a very high level of performance in the detection of paper relations, which is close to that of manual sentence extraction.
Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
Dagna, Alberto; El Abed, Rashid; Hussain, Sameeha; Abu-Tahun, Ibrahim H; Visai, Livia; Bertoglio, Federico; Bosco, Floriana; Beltrami, Riccardo; Poggio, Claudio; Kim, Hyeon-Cheol
2017-11-01
This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups ( p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.
Van der Vorst, Sébastien; Dekairelle, Anne-France; Irenge, Léonid; Hamoir, Marc; Robert, Annie; Gala, Jean-Luc
2009-01-01
This study compared automated vs. manual tissue grinding in terms of RNA yield obtained from oral mucosa biopsies. A total of 20 patients undergoing uvulectomy for sleep-related disorders and 10 patients undergoing biopsy for head and neck squamous cell carcinoma were enrolled in the study. Samples were collected, snap-frozen in liquid nitrogen, and divided into two parts of similar weight. Sample grinding was performed on one sample from each pair, either manually or using an automated cell disruptor. The performance and efficacy of each homogenization approach was compared in terms of total RNA yield (spectrophotometry, fluorometry), mRNA quantity [densitometry of specific TP53 amplicons and TP53 quantitative reverse-transcribed real-time PCR (qRT-PCR)], and mRNA quality (functional analysis of separated alleles in yeast). Although spectrophotometry and fluorometry results were comparable for both homogenization methods, TP53 expression values obtained by amplicon densitometry and qRT-PCR were significantly and consistently better after automated homogenization (p<0.005) for both uvula and tumor samples. Functional analysis of separated alleles in yeast results was better with the automated technique for tumor samples. Automated tissue homogenization appears to be a versatile, quick, and reliable method of cell disruption and is especially useful in the case of small malignant samples, which show unreliable results when processed by manual homogenization.
ERIC Educational Resources Information Center
Macleod, Catriona; Moodley, Dale; Young, Lisa Saville
2015-01-01
This paper compares two forms of sexual socialisation to which learners are exposed: the sexuality education components of the Life Orientation (LO) manuals and the lyrical content and videos of popular songs. We performed a textual analysis of the sexual subject positions made available in, first, the LO manuals used in Grade 10 classes and,…
Designing for User Cognition and Affect in Software Instructions
ERIC Educational Resources Information Center
van der Meij, Hans
2008-01-01
In this paper we examine how to design software instructions for user cognition and affect. A basic and co-user manual are compared. The first provides fundamental support for both; the latter includes a buddy to further optimize support for user affect. The basic manual was faster and judged as easier to process than the co-user manual. In…
Jelicic Kadic, Antonia; Vucic, Katarina; Dosenovic, Svjetlana; Sapunar, Damir; Puljak, Livia
2016-06-01
To compare speed and accuracy of graphical data extraction using manual estimation and open source software. Data points from eligible graphs/figures published in randomized controlled trials (RCTs) from 2009 to 2014 were extracted by two authors independently, both by manual estimation and with the Plot Digitizer, open source software. Corresponding authors of each RCT were contacted up to four times via e-mail to obtain exact numbers that were used to create graphs. Accuracy of each method was compared against the source data from which the original graphs were produced. Software data extraction was significantly faster, reducing time for extraction for 47%. Percent agreement between the two raters was 51% for manual and 53.5% for software data extraction. Percent agreement between the raters and original data was 66% vs. 75% for the first rater and 69% vs. 73% for the second rater, for manual and software extraction, respectively. Data extraction from figures should be conducted using software, whereas manual estimation should be avoided. Using software for data extraction of data presented only in figures is faster and enables higher interrater reliability. Copyright © 2016 Elsevier Inc. All rights reserved.
Automation of immunohistochemical evaluation in breast cancer using image analysis
Prasad, Keerthana; Tiwari, Avani; Ilanthodi, Sandhya; Prabhu, Gopalakrishna; Pai, Muktha
2011-01-01
AIM: To automate breast cancer diagnosis and to study the inter-observer and intra-observer variations in the manual evaluations. METHODS: Breast tissue specimens from sixty cases were stained separately for estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor-2 (HER-2/neu). All cases were assessed by manual grading as well as image analysis. The manual grading was performed by an experienced expert pathologist. To study inter-observer and intra-observer variations, we obtained readings from another pathologist as the second observer from a different laboratory who has a little less experience than the first observer. We also took a second reading from the second observer to study intra-observer variations. Image analysis was carried out using in-house developed software (TissueQuant). A comparison of the results from image analysis and manual scoring of ER, PR and HER-2/neu was also carried out. RESULTS: The performance of the automated analysis in the case of ER, PR and HER-2/neu expressions was compared with the manual evaluations. The performance of the automated system was found to correlate well with the manual evaluations. The inter-observer variations were measured using Spearman correlation coefficient r and 95% confidence interval. In the case of ER expression, Spearman correlation r = 0.53, in the case of PR expression, r = 0.63, and in the case of HER-2/neu expression, r = 0.68. Similarly, intra-observer variations were also measured. In the case of ER, PR and HER-2/neu expressions, r = 0.46, 0.66 and 0.70, respectively. CONCLUSION: The automation of breast cancer diagnosis from immunohistochemically stained specimens is very useful for providing objective and repeatable evaluations. PMID:21611095
Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?
Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P
2015-09-01
This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the tested manual program and less dependent on the user's experience. © Georg Thieme Verlag KG Stuttgart · New York.
Fernández-de-Las-Peñas, C; Cleland, J; Palacios-Ceña, M; Fuensalida-Novo, S; Alonso-Blanco, C; Pareja, J A; Alburquerque-Sendín, F
2017-08-01
People with carpal tunnel syndrome (CTS) exhibit widespread pressure pain and thermal pain hypersensitivity as a manifestation of central sensitization. The aim of our study was to compare the effectiveness of manual therapy versus surgery for improving pain and nociceptive gain processing in people with CTS. The trial was conducted at a local regional Hospital in Madrid, Spain from August 2014 to February 2015. In this randomized parallel-group, blinded, clinical trial, 100 women with CTS were randomly allocated to either manual therapy (n = 50), who received three sessions (once/week) of manual therapies including desensitization manoeuvres of the central nervous system, or surgical intervention (n = 50) group. Outcomes including pressure pain thresholds (PPT), thermal pain thresholds (HPT or CPT), and pain intensity which were assessed at baseline, and 3, 6, 9 and 12 months after the intervention by an assessor unaware of group assignment. Analysis was by intention to treat with mixed ANCOVAs adjusted for baseline scores. At 12 months, 95 women completed the follow-up. Patients receiving manual therapy exhibited higher increases in PPT over the carpal tunnel at 3, 6 and 9 months (all, p < 0.01) and higher decrease of pain intensity at 3 month follow-up (p < 0.001) than those receiving surgery. No significant differences were observed between groups for the remaining outcomes. Manual therapy and surgery have similar effects on decreasing widespread pressure pain sensitivity and pain intensity in women with CTS. Neither manual therapy nor surgery resulted in changes in thermal pain sensitivity. The current study found that manual therapy and surgery exhibited similar effects on decreasing widespread pressure pain sensitivity and pain intensity in women with carpal tunnel syndrome at medium- and long-term follow-ups investigating changes in nociceptive gain processing after treatment in carpal tunnel syndrome. © 2017 European Pain Federation - EFIC®.
Bell, Michael J; Gillespie, Colin S; Swan, Daniel; Lord, Phillip
2012-09-15
Annotations are a key feature of many biological databases, used to convey our knowledge of a sequence to the reader. Ideally, annotations are curated manually, however manual curation is costly, time consuming and requires expert knowledge and training. Given these issues and the exponential increase of data, many databases implement automated annotation pipelines in an attempt to avoid un-annotated entries. Both manual and automated annotations vary in quality between databases and annotators, making assessment of annotation reliability problematic for users. The community lacks a generic measure for determining annotation quality and correctness, which we look at addressing within this article. Specifically we investigate word reuse within bulk textual annotations and relate this to Zipf's Principle of Least Effort. We use the UniProt Knowledgebase (UniProtKB) as a case study to demonstrate this approach since it allows us to compare annotation change, both over time and between automated and manually curated annotations. By applying power-law distributions to word reuse in annotation, we show clear trends in UniProtKB over time, which are consistent with existing studies of quality on free text English. Further, we show a clear distinction between manual and automated analysis and investigate cohorts of protein records as they mature. These results suggest that this approach holds distinct promise as a mechanism for judging annotation quality. Source code is available at the authors website: http://homepages.cs.ncl.ac.uk/m.j.bell1/annotation. phillip.lord@newcastle.ac.uk.
Korczyński, P; Górska, K; Nasiłowski, J; Chazan, R; Krenke, R
2015-01-01
Beside standard chest tube drainage other less invasive techniques have been used in the management of patients with an acute episode of spontaneous pneumothorax. The aim of the study was to evaluate the short term effect of spontaneous pneumothorax treatment with small-bore pleural catheter and manual aspiration as compared to large-bore chest tube drainage. Patients with an episode of pneumothorax who required pleural intervention were enrolled in the study and randomly assigned to one of the treatment arms: (1) small-bore pleural catheter (8 Fr) with manual aspiration; (2) standard chest tube drainage (20-24 Fr). Success rate of the first line treatment, duration of catheter or chest tube drainage, and the need for surgical intervention were the outcome measures. The study group included 49 patients (mean age 46.9±21.3 years); with 22 and 27 allocated to small bore manual aspiration and chest tube drainage groups, respectively. There were no significant differences in the baseline characteristics of patients in both therapeutic arms. First line treatment success rates were 64% and 82% in the manual aspiration and chest tube drainage groups, respectively; the difference was insignificant. Median time of treatment with small bore catheter was significantly shorter than conventional chest tube drainage (2.0 vs. 6.0 days; p<0.05). Our results show that treatment of spontaneous pneumothorax with small-bore pleural catheter and manual aspiration might be similarly effective as is chest tube drainage in terms of immediate lung re-expansion.
Semiautomated digital analysis of knee joint space width using MR images.
Agnesi, Filippo; Amrami, Kimberly K; Frigo, Carlo A; Kaufman, Kenton R
2007-05-01
The goal of this study was to (a) develop a semiautomated computer algorithm to measure knee joint space width (JSW) from magnetic resonance (MR) images using standard imaging techniques and (b) evaluate the reproducibility of the algorithm. Using a standard clinical imaging protocol, bilateral knee MR images were obtained twice within a 2-week period from 17 asymptomatic research participants. Images were analyzed to determine the variability of the measurements performed by the program compared with the variability of manual measurements. Measurement variability of the computer algorithm was considerably smaller than the variability of manual measurements. The average difference between two measurements of the same slice performed with the computer algorithm by the same user was 0.004 +/- 0.07 mm for the tibiofemoral joint (TF) and 0.009 +/- 0.11 mm for the patellofemoral joint (PF) compared with an average of 0.12 +/- 0.22 mm TF and 0.13 +/- 0.29 mm PF, respectively, for the manual method. Interuser variability of the computer algorithm was also considerably smaller, with an average difference of 0.004 +/- 0.1 mm TF and 0.0006 +/- 0.1 mm PF compared with 0.38 +/- 0.59 mm TF and 0.31 +/- 0.66 mm PF obtained using a manual method. The between-day reproducibility was larger but still within acceptable limits at 0.09 +/- 0.39 mm TF and 0.09 +/- 0.51 mm PF. This technique has proven consistently reproducible on a same slice base,while the reproducibility comparing different acquisitions of the same subject was larger. Longitudinal reproducibility improvement needs to be addressed through acquisition protocol improvements. A semiautomated method for measuring knee JSW from MR images has been successfully developed.
Jinadatha, Chetan; Quezada, Ricardo; Huber, Thomas W; Williams, Jason B; Zeber, John E; Copeland, Laurel A
2014-04-07
Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132-304) vs PPX-UV (mean = 449, median = 365, q1-q3 332-530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8-143) vs PPX-UV (mean = 108; median = 123; q1-q3 14-183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4-48). PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms.
2014-01-01
Background Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Methods Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Results Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132–304) vs PPX-UV (mean = 449, median = 365, q1-q3 332–530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8–143) vs PPX-UV (mean = 108; median = 123; q1-q3 14–183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4–48). Conclusion PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms. PMID:24708734
Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M
1997-05-01
To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.
Manjunatha, M; Annapurna, Kini; Sudhakar, V; Sunil Kumar, VC; Hiremath, Vinay Kumar; Shah, Ankur
2013-01-01
Introduction: The aim of any root canal treatment is to achieve a canal free of micro organisms, residual pulp remnants, debris and smear layer for the long term success of the procedure. Manual and automated instrumentation techniques along with proper irrigation regime is used to arrive at the aforementioned goal. Many authors focused on the preparation capabilities of various manual and rotary instruments but very few investigators stressed on the actual cleaning abilities of these instruments. Aims and objectives: This study was undertaken to evaluate the cleaning efficiency of manual K flex files and rotary Pro File systems in the root canals using a scanning electron microscope. Material and Methods:Thirty single rooted mandibular first premolars were divided into two groups and randomized (the manual group-M and the ProFile group-P) with respect to the preparation technique. The Manual group was hand instrumented with stainless steel K- Flexofiles by means of a conventional filing technique. The Pro File group was instrumented according to the manufacturer's instructions using a rotary handpiece. All canals were shaped and cleaned under frequent irrigation with EDTA. Final irrigation was carried out with 3 mL of normal saline solution to neutralize the action of the irrigant. The roots were split, one half of each tooth was selected for further SEM technique analysis and examined under the scanning electron microscope. The canal walls were quantitatively evaluated for the amount of debris and smear layer. The apical, middle and coronal regions of the canal surface, were graded (1-5) for debris and smear layer. A statistical analysis was performed using a Mann-Whitney Rank Sum test. ProFile performed least effective cleaning. Manual K-Flexofiles led to a grooved pattern. Results and Conclusion: A statistically significant difference was observed (p<0.05) between the two instrumentation techniques concerning the amount of debris and smear layer at the apical level. The manually filed canals had less debris and smear layer than those using a rotary technique. It was concluded from this study that none of the instrumentation techniques employed, produced the canal walls which were free of surface debris and smear layer. The manual instrumentation technique was better in cleaning the canals compared to the ProFile rotary Ni-Ti instruments despite the step-back technique used for manual instrumentation. How to cite this article: Manjunatha M, Kini A, Sudhakar V, Sunil K V C, Hiremath V K, Shah A. Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study. J Int Oral Health 2013; 5(1):66-78. PMID:24155580
Weschenfelder, Ann-Kathrin; Reissner, Volker; Knollmann, Martin; Hebebrand, Johannes; Wasem, Jürgen; Neumann, Anja
2018-01-01
Untreated school refusal increases the risk of a premature discontinuation of the educational career. The aim of this study is the economic evaluation of a manual-based treatment for school refusal in comparison to the standard treatment. Within the cost-minimisation analysis, resource use is measured retrospectively for six months using the CSSRI questionnaire. Unit costs for most health care services are derived from published standard prices. Costs are calculated from the societal perspective based on prices compiled in 2011. The cost comparison during the one-year intervention period applies a difference in differences Approach. The most common diagnoses among the 112 participants are phobic and emotional disorders. The average cost per patient during the intervention period amounts to 7197 € (95 %-CI: 4746 € – 10 079 €) for the manual group and 9294 € (95 %-CI: 6313 € – 12 878 €) for the control group. The difference in adjusted costs of 1453 € in favour of the manual group is not statistically relevant. The manual-based treatment is equivalent if not slightly advantageous compared to the standard treatment considering the clinical outcomes and cost of illness.
Travers, Brittany G; Bigler, Erin D; Duffield, Tyler C; Prigge, Molly D B; Froehlich, Alyson L; Lange, Nicholas; Alexander, Andrew L; Lainhart, Janet E
2017-07-01
Many individuals with autism spectrum disorder (ASD) exhibit motor difficulties, but it is unknown whether manual motor skills improve, plateau, or decline in ASD in the transition from childhood into adulthood. Atypical development of manual motor skills could impact the ability to learn and perform daily activities across the life span. This study examined longitudinal grip strength and finger tapping development in individuals with ASD (n = 90) compared to individuals with typical development (n = 56), ages 5 to 40 years old. We further examined manual motor performance as a possible correlate of current and future daily living skills. The group with ASD demonstrated atypical motor development, characterized by similar performance during childhood but increasingly poorer performance from adolescence into adulthood. Grip strength was correlated with current adaptive daily living skills, and Time 1 grip strength predicted daily living skills eight years into the future. These results suggest that individuals with ASD may experience increasingly more pronounced motor difficulties from adolescence into adulthood and that manual motor performance in ASD is related to adaptive daily living skills. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios Velazquez, E; Meier, R; Dunn, W
Purpose: Reproducible definition and quantification of imaging biomarkers is essential. We evaluated a fully automatic MR-based segmentation method by comparing it to manually defined sub-volumes by experienced radiologists in the TCGA-GBM dataset, in terms of sub-volume prognosis and association with VASARI features. Methods: MRI sets of 67 GBM patients were downloaded from the Cancer Imaging archive. GBM sub-compartments were defined manually and automatically using the Brain Tumor Image Analysis (BraTumIA), including necrosis, edema, contrast enhancing and non-enhancing tumor. Spearman’s correlation was used to evaluate the agreement with VASARI features. Prognostic significance was assessed using the C-index. Results: Auto-segmented sub-volumes showedmore » high agreement with manually delineated volumes (range (r): 0.65 – 0.91). Also showed higher correlation with VASARI features (auto r = 0.35, 0.60 and 0.59; manual r = 0.29, 0.50, 0.43, for contrast-enhancing, necrosis and edema, respectively). The contrast-enhancing volume and post-contrast abnormal volume showed the highest C-index (0.73 and 0.72), comparable to manually defined volumes (p = 0.22 and p = 0.07, respectively). The non-enhancing region defined by BraTumIA showed a significantly higher prognostic value (CI = 0.71) than the edema (CI = 0.60), both of which could not be distinguished by manual delineation. Conclusion: BraTumIA tumor sub-compartments showed higher correlation with VASARI data, and equivalent performance in terms of prognosis compared to manual sub-volumes. This method can enable more reproducible definition and quantification of imaging based biomarkers and has a large potential in high-throughput medical imaging research.« less
A proposed power assisted system of manual wheelchair based on universal design for eldery
NASA Astrophysics Data System (ADS)
Susmartini, Susy; Pryadhitama, Ilham; Herdiman, Lobes; Wahyufitriani, Cindy
2017-11-01
Difficulties in walking is high percentage case in the limitations mobility of the elderly. An assisted technology commonly used to help the elderly who have walking difficulty is a manual wheelchair. However, the elderly frequently experiences difficulties in operating manual wheelchair due to gradually degradation of their physical condition. Preliminary study results showed that the average grip strength of the hands of seven elderly subjects was 13.8 ± 6.96 kg and the value is relatively weak. In addition, the mean maximum speed of 7 elderly subjects when doing to round the wheelchair is 0.6 ± 0.2m / s. This value is only 56.4% compared with an average speed of 20-23-year age group (8 males), which is 1.1 ± 0.1 m / s. This shows that the elderly who have walking difficulty have low grip strength and speed in operating a wheelchair. On the other hand, manual wheelchairs suffer an inadequate technology solution to solve the problem. Therefore, an assistive technology is proposed to create mobility aid to accommodate the elderly needs. One approach used is Universal Design. This paper proposes a system of intervention in the manual wheelchair through the 7 principles of Universal Design approach. The preliminary principle has not been able to accommodate the needs of the elderly will become a reference in the proposed design of this study.
Vakil, Eli; Bloch, Ayala; Cohen, Haggar
2017-03-01
The serial reaction time (SRT) task has generated a very large amount of research. Nevertheless the debate continues as to the exact cognitive processes underlying implicit sequence learning. Thus, the first goal of this study is to elucidate the underlying cognitive processes enabling sequence acquisition. We therefore compared reaction time (RT) in sequence learning in a standard manual activated (MA) to that in an ocular activated (OA) version of the task, within a single experimental setting. The second goal is to use eye movement measures to compare anticipation, as an additional indication of sequence learning, between the two versions of the SRT. Performance of the group given the MA version of the task (n = 29) was compared with that of the group given the OA version (n = 30). The results showed that although overall, RT was faster for the OA group, the rate of sequence learning was similar to that of the MA group performing the standard version of the SRT. Because the stimulus-response association is automatic and exists prior to training in the OA task, the decreased reaction time in this version of the task reflects a purer measure of the sequence learning that occurs in the SRT task. The results of this study show that eye tracking anticipation can be measured directly and can serve as a direct measure of sequence learning. Finally, using the OA version of the SRT to study sequence learning presents a significant methodological contribution by making sequence learning studies possible among populations that struggle to perform manual responses.
Comparability of automated human induced pluripotent stem cell culture: a pilot study.
Archibald, Peter R T; Chandra, Amit; Thomas, Dave; Chose, Olivier; Massouridès, Emmanuelle; Laâbi, Yacine; Williams, David J
2016-12-01
Consistent and robust manufacturing is essential for the translation of cell therapies, and the utilisation automation throughout the manufacturing process may allow for improvements in quality control, scalability, reproducibility and economics of the process. The aim of this study was to measure and establish the comparability between alternative process steps for the culture of hiPSCs. Consequently, the effects of manual centrifugation and automated non-centrifugation process steps, performed using TAP Biosystems' CompacT SelecT automated cell culture platform, upon the culture of a human induced pluripotent stem cell (hiPSC) line (VAX001024c07) were compared. This study, has demonstrated that comparable morphologies and cell diameters were observed in hiPSCs cultured using either manual or automated process steps. However, non-centrifugation hiPSC populations exhibited greater cell yields, greater aggregate rates, increased pluripotency marker expression, and decreased differentiation marker expression compared to centrifugation hiPSCs. A trend for decreased variability in cell yield was also observed after the utilisation of the automated process step. This study also highlights the detrimental effect of the cryopreservation and thawing processes upon the growth and characteristics of hiPSC cultures, and demonstrates that automated hiPSC manufacturing protocols can be successfully transferred between independent laboratories.
Sng, Ban Leong; Du, Wei; Lee, Man Xin; Ithnin, Farida; Mathur, Deepak; Leong, Wan Ling; Sultana, Rehena; Han, Nian-Lin R; Sia, Alex Tiong Heng
2018-05-01
Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. A randomised, double-blind controlled trial. Single-centre, KK Women's and Children's Hospital, Singapore. Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. Clinicaltrials.gov identifier: NCT02277730.
Green, M J; Benzeval, M
2011-03-01
Understanding how common mental disorders such as anxiety and depression vary with socio-economic circumstances as people age can help to identify key intervention points. However, much research treats these conditions as a single disorder when they differ significantly in terms of their disease burden. This paper examines the socio-economic pattern of anxiety and depression separately and longitudinally to develop a better understanding of their disease burden for key social groups at different ages. The Twenty-07 Study has followed 4510 respondents from three cohorts in the West of Scotland for 20 years and 3846 respondents had valid data for these analyses. Hierarchical repeated-measures models were used to investigate the relationship between age, social class and the prevalence of anxiety and depression over time measured as scores of 8 or more out of 21 on the relevant subscale of the Hospital Anxiety and Depression Scale (HADS). Social class differences in anxiety and depression widened with age. For anxiety there was a nonlinear decrease in prevalence with age, decreasing more slowly for those from manual classes compared to non-manual, whereas for depression there was a non-linear increase in prevalence with age, increasing more quickly for those from manual classes compared to non-manual. This relationship is robust to cohort, period and attrition effects. The more burdensome disorder of depression occurs more frequently at ages where socio-economic inequalities in mental health are greatest, representing a 'double jeopardy' for older people from a manual class.
Lüddemann, Tobias; Egger, Jan
2016-01-01
Abstract. Among all types of cancer, gynecological malignancies belong to the fourth most frequent type of cancer among women. In addition to chemotherapy and external beam radiation, brachytherapy is the standard procedure for the treatment of these malignancies. In the progress of treatment planning, localization of the tumor as the target volume and adjacent organs of risks by segmentation is crucial to accomplish an optimal radiation distribution to the tumor while simultaneously preserving healthy tissue. Segmentation is performed manually and represents a time-consuming task in clinical daily routine. This study focuses on the segmentation of the rectum/sigmoid colon as an organ-at-risk in gynecological brachytherapy. The proposed segmentation method uses an interactive, graph-based segmentation scheme with a user-defined template. The scheme creates a directed two-dimensional graph, followed by the minimal cost closed set computation on the graph, resulting in an outlining of the rectum. The graph’s outline is dynamically adapted to the last calculated cut. Evaluation was performed by comparing manual segmentations of the rectum/sigmoid colon to results achieved with the proposed method. The comparison of the algorithmic to manual result yielded a dice similarity coefficient value of 83.85±4.08, in comparison to 83.97±8.08% for the comparison of two manual segmentations by the same physician. Utilizing the proposed methodology resulted in a median time of 128 s/dataset, compared to 300 s needed for pure manual segmentation. PMID:27403448
Hwang, Mi-Jung; Seol, Geun Hee
2015-01-01
Heel blood sampling is a common but painful procedure for neonates. Automatic lancets have been shown to be more effective, with reduced pain and tissue damage, than manual lancets, but the effects of lancet type on cortical activation have not yet been compared. The study aimed to compare the effects of manual and automatic lancets on cerebral oxygenation and pain of heel blood sampling in 24 premature infants with respiratory distress syndrome. Effectiveness was measured by assessing numbers of pricks and squeezes and duration of heel blood sampling. Pain responses were measured using the premature infant pain profile score, heart rate, and oxygen saturation (SpO2). Regional cerebral oxygen saturation (rScO2) was measured using near-infrared spectroscopy, and cerebral fractional tissue oxygen extraction was calculated from SpO2 and rScO. Measures of effectiveness were significantly better with automatic than with manual lancing, including fewer heel punctures (P = .009) and squeezes (P < .001) and shorter duration of heel blood sampling (P = .002). rScO2 was significantly higher (P = .013) and cerebral fractional tissue oxygen extraction after puncture significantly lower (P = .040) with automatic lancing. Premature infant pain profile scores during (P = .004) and after (P = .048) puncture were significantly lower in the automatic than in the manual lancet group. Automatic lancets for heel blood sampling in neonates with respiratory distress syndrome significantly reduced pain and enhanced cerebral oxygenation, suggesting that heel blood should be sampled routinely using an automatic lancet.
Holmström, Oscar; Linder, Nina; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Turkki, Riku; Joensuu, Heikki; Isola, Jorma; Diwan, Vinod; Lundin, Johan
2015-01-01
Introduction A significant barrier to medical diagnostics in low-resource environments is the lack of medical care and equipment. Here we present a low-cost, cloud-connected digital microscope for applications at the point-of-care. We evaluate the performance of the device in the digital assessment of estrogen receptor-alpha (ER) expression in breast cancer samples. Studies suggest computer-assisted analysis of tumor samples digitized with whole slide-scanners may be comparable to manual scoring, here we study whether similar results can be obtained with the device presented. Materials and Methods A total of 170 samples of human breast carcinoma, immunostained for ER expression, were digitized with a high-end slide-scanner and the point-of-care microscope. Corresponding regions from the samples were extracted, and ER status was determined visually and digitally. Samples were classified as ER negative (<1% ER positivity) or positive, and further into weakly (1–10% positivity) and strongly positive. Interobserver agreement (Cohen’s kappa) was measured and correlation coefficients (Pearson’s product-momentum) were calculated for comparison of the methods. Results Correlation and interobserver agreement (r = 0.98, p < 0.001, kappa = 0.84, CI95% = 0.75–0.94) were strong in the results from both devices. Concordance of the point-of-care microscope and the manual scoring was good (r = 0.94, p < 0.001, kappa = 0.71, CI95% = 0.61–0.80), and comparable to the concordance between the slide scanner and manual scoring (r = 0.93, p < 0.001, kappa = 0.69, CI95% = 0.60–0.78). Fourteen (8%) discrepant cases between manual and device-based scoring were present with the slide scanner, and 16 (9%) with the point-of-care microscope, all representing samples of low ER expression. Conclusions Tumor ER status can be accurately quantified with a low-cost imaging device and digital image-analysis, with results comparable to conventional computer-assisted or manual scoring. This technology could potentially be expanded for other histopathological applications at the point-of-care. PMID:26659386
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, T; Ding, H; Torabzadeh, M
2015-06-15
Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing amore » contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.« less
[Manual trigger point therapy of shoulder pain : Randomized controlled study of effectiveness].
Sohns, S; Schnieder, K; Licht, G; von Piekartz, H
2016-12-01
Although chronic shoulder pain is highly prevalent and myofascial trigger points (mTrP) are thought to be found in the majority of patients with shoulder complaints, the influence on the pain mechanism remains unclear. There are only very few controlled clinical studies on the effects of manual trigger point compression therapy. This randomized controlled trial (RCT) compared the short-term effects of manual trigger point compression therapy (n = 6) with manual sham therapy (n = 6) in patients with unilateral shoulder pain due to myofascial syndrome (MFS). The measurement data were collected before and after two sessions of therapy. Pressure pain thresholds (PPT) of mTrP and symmetrically located points on the asymptomatic side were measured together with neutral points in order to detect a potential unilateral or generalized hyperalgesia. Additionally, the pain was assessed on a visual analog scale (VAS) at rest and during movement and the neck disability index (NDI) and disabilities of the arm, shoulder and hand (DASH) questionnaires were also completed and evaluated. Both treatment modalities led to a significant improvement; however, the manual trigger point compression therapy was significantly more effective in comparison to sham therapy, as measured by different parameters. The significant improvement of PPT values in the interventional group even at sites that were not directly treated, indicates central mechanisms in pain threshold modulation induced by manual compression therapy. The weaker but still measurable effects of sham therapy might be explained by the sham modality being a hands on technique or by sufficient stimulation of the trigger point region during the diagnostics and PPT measurements.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Yip, Eugene; Yun, Jihyun; Gabos, Zsolt; Baker, Sarah; Yee, Don; Wachowicz, Keith; Rathee, Satyapal; Fallone, B Gino
2018-01-01
Real-time tracking of lung tumors using magnetic resonance imaging (MRI) has been proposed as a potential strategy to mitigate the ill-effects of breathing motion in radiation therapy. Several autocontouring methods have been evaluated against a "gold standard" of a single human expert user. However, contours drawn by experts have inherent intra- and interobserver variations. In this study, we aim to evaluate our user-trained autocontouring algorithm with manually drawn contours from multiple expert users, and to contextualize the accuracy of these autocontours within intra- and interobserver variations. Six nonsmall cell lung cancer patients were recruited, with institutional ethics approval. Patients were imaged with a clinical 3 T Philips MR scanner using a dynamic 2D balanced SSFP sequence under free breathing. Three radiation oncology experts, each in two separate sessions, contoured 130 dynamic images for each patient. For autocontouring, the first 30 images were used for algorithm training, and the remaining 100 images were autocontoured and evaluated. Autocontours were compared against manual contours in terms of Dice's coefficient (DC) and Hausdorff distances (d H ). Intra- and interobserver variations of the manual contours were also evaluated. When compared with the manual contours of the expert user who trained it, the algorithm generates autocontours whose evaluation metrics (same session: DC = 0.90(0.03), d H = 3.8(1.6) mm; different session DC = 0.88(0.04), d H = 4.3(1.5) mm) are similar to or better than intraobserver variations (DC = 0.88(0.04), and d H = 4.3(1.7) mm) between two sessions. The algorithm's autocontours are also compared to the manual contours from different expert users with evaluation metrics (DC = 0.87(0.04), d H = 4.8(1.7) mm) similar to interobserver variations (DC = 0.87(0.04), d H = 4.7(1.6) mm). Our autocontouring algorithm delineates tumor contours (<20 ms per contour), in dynamic MRI of lung, that are comparable to multiple human experts (several seconds per contour), but at a much faster speed. At the same time, the agreement between autocontours and manual contours is comparable to the intra- and interobserver variations. This algorithm may be a key component of the real time tumor tracking workflow for our hybrid Linac-MR device in the future. © 2017 American Association of Physicists in Medicine.
Rolling resistance and propulsion efficiency of manual and power-assisted wheelchairs.
Pavlidou, Efthymia; Kloosterman, Marieke G M; Buurke, Jaap H; Rietman, Johan S; Janssen, Thomas W J
2015-11-01
Rolling resistance is one of the main forces resisting wheelchair propulsion and thus affecting stress exerted on the upper limbs. The present study investigates the differences in rolling resistance, propulsion efficiency and energy expenditure required by the user during power-assisted and manual propulsion. Different tire pressures (50%, 75%, 100%) and two different levels of motor assistance were tested. Drag force, energy expenditure and propulsion efficiency were measured in 10 able-bodied individuals under different experimental settings on a treadmill. Results showed that drag force levels were significantly higher in the 50%, compared to the 75% and 100% inflation conditions. In terms of wheelchair type, the manual wheelchair displayed significantly lower drag force values than the power-assisted one. The use of extra-power-assisted wheelchair appeared to be significantly superior to conventional power-assisted and manual wheelchairs concerning both propulsion efficiency and energy expenditure required by the user. Overall, the results of the study suggest that the use of power-assisted wheelchair was more efficient and required less energy input by the user, depending on the motor assistance provided. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Berger, Moritz; Nova, Igor; Kallus, Sebastian; Ristow, Oliver; Eisenmann, Urs; Dickhaus, Hartmut; Engel, Michael; Freudlsperger, Christian; Hoffmann, Jürgen; Seeberger, Robin
2018-05-01
Reproduction of the exact preoperative proximal-mandible position after osteotomy in orthognathic surgery is difficult to achieve. This clinical pilot study evaluated an electromagnetic (EM) navigation system for condylar positioning after high-oblique sagittal split osteotomy (HSSO). After HSSO as part of 2-jaw surgery, the position of 10 condyles was intraoperatively guided by an EM navigation system. As controls, 10 proximal segments were positioned by standard manual replacement. Accuracy was measured by pre- and postoperative cone beam computed tomography imaging. Overall, EM condyle repositioning was equally accurate compared with manual repositioning (P > .05). Subdivided into 3 axes, significant differences could be identified (P < .05). Nevertheless, no significantly and clinically relevant dislocations of the proximal segment of either the EM or the manual repositioning method could be shown (P > .05). This pilot study introduces a guided method for proximal segment positioning after HSSO by applying the intraoperative EM system. The data demonstrate the high accuracy of EM navigation, although manual replacement of the condyles could not be surpassed. However, EM navigation can avoid clinically hidden, severe malpositioning of the condyles. Copyright © 2017 Elsevier Inc. All rights reserved.
Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.
ERIC Educational Resources Information Center
Brody, Michelle L.; And Others
1994-01-01
Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…
Abbott, J Haxby; Chapple, Catherine M; Fitzgerald, G Kelley; Fritz, Julie M; Childs, John D; Harcombe, Helen; Stout, Kirsten
2015-12-01
A factorial randomized controlled trial. To investigate the addition of manual therapy to exercise therapy for the reduction of pain and increase of physical function in people with knee osteoarthritis (OA), and whether "booster sessions" compared to consecutive sessions may improve outcomes. The benefits of providing manual therapy in addition to exercise therapy, or of distributing treatment sessions over time using periodic booster sessions, in people with knee OA are not well established. All participants had knee OA and were provided 12 sessions of multimodal exercise therapy supervised by a physical therapist. Participants were randomly allocated to 1 of 4 groups: exercise therapy in consecutive sessions, exercise therapy distributed over a year using booster sessions, exercise therapy plus manual therapy without booster sessions, and exercise therapy plus manual therapy with booster sessions. The primary outcome measure was the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC score; 0-240 scale) at 1-year follow-up. Secondary outcome measures were the numeric pain-rating scale and physical performance tests. Of 75 participants recruited, 66 (88%) were retained at 1-year follow-up. Factorial analysis of covariance of the main effects showed significant benefit from booster sessions (P = .009) and manual therapy (P = .023) over exercise therapy alone. Group analysis showed that exercise therapy with booster sessions (WOMAC score, -46.0 points; 95% confidence interval [CI]: -80.0, -12.0) and exercise therapy plus manual therapy (WOMAC score, -37.5 points; 95% CI: -69.7, -5.5) had superior effects compared with exercise therapy alone. The combined strategy of exercise therapy plus manual therapy with booster sessions was not superior to exercise therapy alone. Distributing 12 sessions of exercise therapy over a year in the form of booster sessions was more effective than providing 12 consecutive exercise therapy sessions. Providing manual therapy in addition to exercise therapy improved treatment effectiveness compared to providing 12 consecutive exercise therapy sessions alone. Trial registered with the Australian New Zealand Clinical Trials Registry (ACTRN12612000460808).
ERIC Educational Resources Information Center
van der Meer, Larah; Sutherland, Dean; O'Reilly, Mark F.; Lancioni, Giulio E.; Sigafoos, Jeff
2012-01-01
We compared acquisition of, and preference for, manual signing (MS), picture exchange (PE), and speech-generating devices (SGDs) in four children with autism spectrum disorders (ASD). Intervention was introduced across participants in a non-concurrent multiple-baseline design and acquisition of the three communication modes was compared in an…
A pilot study of myofascial release therapy compared to Swedish massage in fibromyalgia.
Liptan, Ginevra; Mist, Scott; Wright, Cheryl; Arzt, Anna; Jones, Kim Dupree
2013-07-01
Fibromyalgia (FM) is characterized by widespread muscle pain and soft tissue tenderness. However, a lack of definitive muscle pathology has made FM both a diagnostic and a treatment puzzle. Much of the evidence for pathology in FM lies in the central nervous system - in particular abnormal amplification of pain signals in the spinal cord - a manifestation of central sensitization. An emerging body of evidence posits that peripheral pain generated from the muscles and fascia may trigger and maintain central sensitization in FM. Since FM patients so frequently seek manual therapy to relieve muscle symptoms, the present study compared two different manual therapy techniques in a parallel study of women with FM. Eight subjects received myofascial release (MFR) while four subjects received Swedish massage, 90 min weekly for four weeks. Overall symptom burden and physical function were assessed by the Fibromyalgia Impact Questionnaire Revised (FIQ-R). A unique challenge for the manual therapist in treating conditions involving central sensitization is to determine if localized pain reduction can be achieved with targeted therapy in the context of ongoing widespread pain. Localized pain improvement was measured by a novel questionnaire developed for this study, the modified Nordic Musculoskeletal Questionnaire (NMQ). Between-group differences in FIQ-R did not reach statistical significance, but the total change scores on FIQ-R for the MFR group (mean = 10.14, SD = 16.2) trended in the hypothesized and positive direction compared to the Swedish massage group (mean = 0.33, SD = 4.93) yielding a positive Aikin separation test. Although overall modified NMQ scores improved in both groups there were no consistent focal areas of improvement for the Swedish massage group. In contrast, the MFR group reported consistent pain reductions in the neck and upper back regions on the NMQ. These data support the need for larger randomized controlled trials of MFR versus other massage techniques and support the assessment of localized pain reduction in future manual therapy studies in FM. Copyright © 2012 Elsevier Ltd. All rights reserved.
Arya, Ashtha; Bali, Dildeep; Grewal, Mandeep S
2011-07-01
To compare the cleaning efficiency of manual and rotary instrumentation in the apical third of the root canal system. In group 1 (n=10), instrumentation was performed with stainless steel K-file; in group 2 (n=10), it was done with hand ProTaper files; and in group 3 (n=10), instrumentation was done with ProTaper rotary. Distilled water was used for irrigation. The apical third was sectioned transversally and histologically processed. The cross sections were examined under optic microscope and debris was measured using Motic software. Instrumentation with stainless steel K-files showed minimum amount of debris, followed by ProTaper hand files, and rotary ProTaper files were least effective with maximum amount of debris; however, there were no significant differences between the three experimental groups. Both the manual and rotary instrumentation are relatively efficient in cleaning the apical third of the root canal system and the choice between manual and rotary instrumentation should depend on case to case basis.
Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J
2015-01-01
The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.
End-user satisfaction of a patient education tool manual versus computer-generated tool.
Tronni, C; Welebob, E
1996-01-01
This article reports a nonexperimental comparative study of end-user satisfaction before and after implementation of a vendor supplied computerized system (Micromedex, Inc) for providing up-to-date patient instructions regarding diseases, injuries, procedures, and medications. The purpose of this research was to measure the satisfaction of nurses who directly interact with a specific patient educational software application and to compare user satisfaction with manual versus computer generated materials. A computing satisfaction questionnaire that uses a scale of 1 to 5 (1 being the lowest) was used to measure end-user computing satisfaction in five constructs: content, accuracy, format, ease of use, and timeliness. Summary statistics were used to calculate mean ratings for each of the questionnaire's 12 items and for each of the five constructs. Mean differences between the ratings before and after implementation of the five constructs were significant by paired t test. Total user satisfaction improved with the computerized system, and the computer generated materials were given a higher rating than were the manual materials. Implications of these findings are discussed.
A comparison of manual and controlled-force attachment-level measurements.
Reddy, M S; Palcanis, K G; Geurs, N C
1997-12-01
This study compared the intra-examiner and inter-examiner error of 2 constant force probes to the reading of a conventional manual probe. 3 examiners made repeated examinations of attachment level using a modified Florida probe and a manual North Carolina probe (read to 1 mm or 0.5 mm); relative attachment level measurements were made using a Florida disk probe. One probe was used in each quadrant in 8 subjects with moderate to advanced periodontitis. Error was calculated as the mean of the absolute value of the difference between each examination, and the correlation between values at each examination calculated. Statistically-significant differences between probe type, examiners, and sites were detected using a repeated measures ANOVA accounting for the nesting within subjects. There was a significant difference in error by probe type (modified Florida probe 0.62 +/- 0.03 mm, r = 0.86; Florida stent probe 0.55 +/- 0.05 mm, r = 0.82; manual probe to 1 mm 0.39 +/- 0.02 mm, r = 0.88; manual probe to 0.5 mm 0.40 +/- 0.02 mm, r = 0.89; (p < 0.001). Significant differences were observed by examiners (p < 0.01). These data indicate that both manual and controlled-force probes can provide measurement within less than 1 mm of error; however, individual calibration of examiners remains important in the reduction of error.
Lee, Na Ra; Kim, Soo Byeong; Heo, Hyun; Lee, Yong Heum
2016-10-01
The aim of this study was to compare the influences of manual acupuncture, laser acupuncture, and electromagnetic field stimulation on the autonomic nervous system. We monitored the heart rate variability before and after stimulation to check the influence on the autonomic nervous system. The heart rate variabilities at low frequency (LF; 0.04-0.15 Hz) and high frequency (HF; 0.15-0.4 Hz) were analyzed to acquire LF/HF ratio. Xinshu (BL15) was selected as the stimulation point. Methods included manual acupuncture with a 1-cm depth and laser acupuncture at a wavelength of 660 nm and output power of 50 mW. An electromagnetic field of 2 Hz and 460 gauss (46 mT) was chosen. The LF and the LF/HF ratio were found to be lower in the manual acupuncture and the electromagnetic field groups, but to be higher in the laser acupuncture group. The HF was found to be lower in the laser acupuncture group, but higher in the manual acupuncture and the electromagnetic field groups. In conclusion, we found that manual acupuncture and electromagnetic field stimulation at BL15 activated the parasympathetic nervous system, whereas laser acupuncture at BL15 activated the sympathetic nervous system. Copyright © 2016. Published by Elsevier B.V.
Grindstaff, Terry L; Pietrosimone, Brian G; Sauer, Lindsay D; Kerrigan, D Casey; Patrie, James T; Hertel, Jay; Ingersoll, Christopher D
2014-08-01
Manual therapies, directed to the knee and lumbopelvic region, have demonstrated the ability to improve neuromuscular quadriceps function in individuals with knee pathology. It remains unknown if manual therapies may alter impaired spinal reflex excitability, thus identifying a potential mechanism in which manual therapy may improve neuromuscular function following knee injury. To determine the effect of local and distant mobilisation/manipulation interventions on quadriceps spinal reflex excitability. Seventy-five individuals with a history of knee joint injury and current quadriceps inhibition volunteered for this study. Participants were randomised to one of five intervention groups: lumbopelvic manipulation (grade V), lumbopelvic manipulation positioning (no thrust), grade IV patellar mobilisation, grade I patellar mobilisation, and control (no treatment). Changes in spinal reflex excitability were quantified by assessing the Hoffmann reflex (H-reflex), presynaptic, and postsynaptic excitability. A hierarchical linear-mixed model for repeated measures was performed to compare changes in outcome variables between groups over time (pre, post 0, 30, 60, 90 min). There were no significant differences in H-reflex, presynaptic, or postsynaptic excitability between groups across time. Manual therapies directed to the knee or lumbopelvic region did not acutely change quadriceps spinal reflex excitability. Although manual therapies may improve impairments and functional outcomes the underlying mechanism does not appear to be related to changes in spinal reflex excitability. Copyright © 2014 Elsevier Ltd. All rights reserved.
Plaster, Ralph; Vieira, Wellington Bueno; Alencar, Flávia Alves Duarte; Nakano, Eduardo Yoshio; Liebano, Richard Eloin
2014-06-01
To compare the immediate effects of electroacupuncture and manual acupuncture on pain, mobility and muscle strength in patients with knee osteoarthritis. Sixty patients with knee osteoarthritis, with a pain intensity of ≥2 on the pain Numerical Rating Scale, were included. The patients were randomised into two groups: manual acupuncture and electroacupuncture. Pain intensity, degree of dysfunction (Timed Up and Go (TUG) test), maximal voluntary isometric contraction and pressure pain threshold were assessed before and after a single session of manual acupuncture or electroacupuncture treatments. Both groups showed a significant reduction in pain intensity (p<0.001) and time to run the TUG test after the acupuncture treatment (p=0.005 for the manual acupuncture group and p=0.002 for the electroacupuncture group). There were no differences between the groups regarding pain intensity (p=0.25), TUG test (p=0.70), maximum voluntary isometric contraction (p=0.43) or pressure pain threshold (p=0.27). This study found no difference between the immediate effects of a single session of manual acupuncture and electroacupuncture on pain, muscle strength and mobility in patients with knee osteoarthritis. RBR-9TCN2X. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Fully automatic registration and segmentation of first-pass myocardial perfusion MR image sequences.
Gupta, Vikas; Hendriks, Emile A; Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F
2010-11-01
Derivation of diagnostically relevant parameters from first-pass myocardial perfusion magnetic resonance images involves the tedious and time-consuming manual segmentation of the myocardium in a large number of images. To reduce the manual interaction and expedite the perfusion analysis, we propose an automatic registration and segmentation method for the derivation of perfusion linked parameters. A complete automation was accomplished by first registering misaligned images using a method based on independent component analysis, and then using the registered data to automatically segment the myocardium with active appearance models. We used 18 perfusion studies (100 images per study) for validation in which the automatically obtained (AO) contours were compared with expert drawn contours on the basis of point-to-curve error, Dice index, and relative perfusion upslope in the myocardium. Visual inspection revealed successful segmentation in 15 out of 18 studies. Comparison of the AO contours with expert drawn contours yielded 2.23 ± 0.53 mm and 0.91 ± 0.02 as point-to-curve error and Dice index, respectively. The average difference between manually and automatically obtained relative upslope parameters was found to be statistically insignificant (P = .37). Moreover, the analysis time per slice was reduced from 20 minutes (manual) to 1.5 minutes (automatic). We proposed an automatic method that significantly reduced the time required for analysis of first-pass cardiac magnetic resonance perfusion images. The robustness and accuracy of the proposed method were demonstrated by the high spatial correspondence and statistically insignificant difference in perfusion parameters, when AO contours were compared with expert drawn contours. Copyright © 2010 AUR. Published by Elsevier Inc. All rights reserved.
Murthy, Prashanth Sadashiva; Shaik, Naseemoon; Deshmukh, Seema; Girish, M. S.
2018-01-01
Background: Establishing good hygiene habits are valuable for present and future oral health. Below 6 years, tooth brushing should be performed by parents, as increasing dexterity and cognition may permit supervised brushing until the child is capable of independent brushing. Aim and Objectives: The aim of the present study was to evaluate the effectiveness of modified oral irrigation device in children in terms of plaque control and to compare the effectiveness of plaque control with manual brushing with the modified oral irrigation device in children. Materials and Methods: A randomized clinical trial was performed on 12 subjects who were allocated to the two study groups. After obtaining the consent, the control group was instructed tooth brushing with regular pediatric commercially available toothbrush and the intervention group with modified oral irrigation device. Plaque scores in both groups were assessed pre- and post-brushing using modified navy plaque index. Results: The data were subjected to Descriptive statistics and Paired t-test using SPSS version 22. Intragroup comparison of mean difference of plaque score in control group and intervention group pre- and post-brushing was statistically significant. Intergroup comparison of manual brushing group with modified oral irrigation group shows P < 0.05 was statistically significant. Conclusion: Within the limitation of the present study, it has been found novel pediatric oral hygiene need Station is more effective than manual brushing since it combined the effect of brushing, flossing (water floss), and rinsing in children simultaneously and at the same time did not demand any special motor skill. PMID:29875555
Pumberger, Matthias; Hughes, Alexander P; Girardi, Federico P; Gogia, Jaspaul; Kotwal, Suhel Y; Thaler, Christoph; Sama, Andrew A
2012-12-01
Cadaveric study. The purpose of this study was to assess the influence of surgical experience on the efficiency of lumbar discectomy in open transforaminal lumbar interbody fusion. There is limited knowledge about the efficiency of discectomy among surgeons. As a first study, we are evaluating the effect of surgical experience on it. Manual and powered discectomies were randomized and performed by 3 attending spine surgeons and 2 clinical spine fellows. Each discectomy procedure was analyzed for the area of complete endplate preparation, total elapsed time, and number of instrument passes. The surface area of discectomy at each endplate was measured utilizing digital imaging and the appropriate software. For the purpose of the analysis, the superior and the inferior endplates were divided into ipsilateral and contralateral halves, and each half was further divided into ventral and dorsal quadrants. Each quadrant was analyzed in a blinded manner by 2 observers. A total of 40 discectomies were performed on 9 fresh-frozen cadaveric torsos between the levels T12 and S1. A powered discectomy device was used in levels 9 and 11 by the attendings. Manual discectomy was performed in 11 levels by the spine fellows and 9 by the spine attendings. No significant difference was observed between the spine fellows and spine attendings when the manual instruments were used (P = 0.924). However, the spine attending surgeon group had a significantly increased total area of discectomy compared with the fellows (P = 0.003). No significant difference was observed between the groups when instrument passes or the total elapsed time were compared either utilizing the manual or the powered technique. Our results demonstrate that a satisfactory discectomy may be performed by surgeons with relatively less surgical experience in the transforaminal approach using a powered discectomy device.
Implicit Measures of Association in Psychopathology Research
ERIC Educational Resources Information Center
Roefs, Anne; Huijding, Jorg; Smulders, Fren T. Y.; MacLeod, Colin M.; de Jong, Peter J.; Wiers, Reinout W.; Jansen, Anita T. M.
2011-01-01
Validity;Measures (Individuals);Studies obtaining implicit measures of associations in "Diagnostic and Statistical Manual of Mental Disorders" (4th ed., Text Revision; American Psychiatric Association, 2000) Axis I psychopathology are organized into three categories: (a) studies comparing groups having a disorder with controls, (b) experimental…
Koplan, Bruce A; Gilligan, David M; Nguyen, Luc S; Lau, Theodore K; Thackeray, Lisa M; Berg, Kellie Chase
2008-11-01
An automatic capture (AC) algorithm adjusts ventricular pacing output to capture the ventricle while optimizing output to 0.5 V above threshold. AC maintains this output and confirms capture on a beat-to-beat basis in bipolar and unipolar pacing and sensing. To assess the AC algorithm and its impact on device longevity. Patients implanted with a pacemaker were randomized 1:1 to have the AC feature on or off for 12 months. Two threshold tests were conducted at each visit- automatic threshold and manual threshold. Average ventricular voltage output and projected device longevity were compared between AC on and off using nonparametric tests. Nine hundred ten patients were enrolled and underwent device implantation. Average ventricular voltage output was 1.6 V for the AC on arm (n = 444) and 3.1 V for the AC off arm (n = 446) (P < 0.001). Projected device longevity was 10.3 years for AC on and 8.9 years for AC off (P < 0.0001), or a 16% increase in longevity for AC on. The proportion of patients in whom there was a difference between automatic threshold and manual threshold of
Real-time segmentation of burst suppression patterns in critical care EEG monitoring
Westover, M. Brandon; Shafi, Mouhsin M.; Ching, ShiNung; Chemali, Jessica J.; Purdon, Patrick L.; Cash, Sydney S.; Brown, Emery N.
2014-01-01
Objective Develop a real-time algorithm to automatically discriminate suppressions from non-suppressions (bursts) in electroencephalograms of critically ill adult patients. Methods A real-time method for segmenting adult ICU EEG data into bursts and suppressions is presented based on thresholding local voltage variance. Results are validated against manual segmentations by two experienced human electroencephalographers. We compare inter-rater agreement between manual EEG segmentations by experts with inter-rater agreement between human vs automatic segmentations, and investigate the robustness of segmentation quality to variations in algorithm parameter settings. We further compare the results of using these segmentations as input for calculating the burst suppression probability (BSP), a continuous measure of depth-of-suppression. Results Automated segmentation was comparable to manual segmentation, i.e. algorithm-vs-human agreement was comparable to human-vs-human agreement, as judged by comparing raw EEG segmentations or the derived BSP signals. Results were robust to modest variations in algorithm parameter settings. Conclusions Our automated method satisfactorily segments burst suppression data across a wide range adult ICU EEG patterns. Performance is comparable to or exceeds that of manual segmentation by human electroencephalographers. Significance Automated segmentation of burst suppression EEG patterns is an essential component of quantitative brain activity monitoring in critically ill and anesthetized adults. The segmentations produced by our algorithm provide a basis for accurate tracking of suppression depth. PMID:23891828
Real-time segmentation of burst suppression patterns in critical care EEG monitoring.
Brandon Westover, M; Shafi, Mouhsin M; Ching, Shinung; Chemali, Jessica J; Purdon, Patrick L; Cash, Sydney S; Brown, Emery N
2013-09-30
Develop a real-time algorithm to automatically discriminate suppressions from non-suppressions (bursts) in electroencephalograms of critically ill adult patients. A real-time method for segmenting adult ICU EEG data into bursts and suppressions is presented based on thresholding local voltage variance. Results are validated against manual segmentations by two experienced human electroencephalographers. We compare inter-rater agreement between manual EEG segmentations by experts with inter-rater agreement between human vs automatic segmentations, and investigate the robustness of segmentation quality to variations in algorithm parameter settings. We further compare the results of using these segmentations as input for calculating the burst suppression probability (BSP), a continuous measure of depth-of-suppression. Automated segmentation was comparable to manual segmentation, i.e. algorithm-vs-human agreement was comparable to human-vs-human agreement, as judged by comparing raw EEG segmentations or the derived BSP signals. Results were robust to modest variations in algorithm parameter settings. Our automated method satisfactorily segments burst suppression data across a wide range adult ICU EEG patterns. Performance is comparable to or exceeds that of manual segmentation by human electroencephalographers. Automated segmentation of burst suppression EEG patterns is an essential component of quantitative brain activity monitoring in critically ill and anesthetized adults. The segmentations produced by our algorithm provide a basis for accurate tracking of suppression depth. Copyright © 2013 Elsevier B.V. All rights reserved.
Evaluation of an artificial intelligence guided inverse planning system: clinical case study.
Yan, Hui; Yin, Fang-Fang; Willett, Christopher
2007-04-01
An artificial intelligence (AI) guided method for parameter adjustment of inverse planning was implemented on a commercial inverse treatment planning system. For evaluation purpose, four typical clinical cases were tested and the results from both plans achieved by automated and manual methods were compared. The procedure of parameter adjustment mainly consists of three major loops. Each loop is in charge of modifying parameters of one category, which is carried out by a specially customized fuzzy inference system. A physician prescribed multiple constraints for a selected volume were adopted to account for the tradeoff between prescription dose to the PTV and dose-volume constraints for critical organs. The searching process for an optimal parameter combination began with the first constraint, and proceeds to the next until a plan with acceptable dose was achieved. The initial setup of the plan parameters was the same for each case and was adjusted independently by both manual and automated methods. After the parameters of one category were updated, the intensity maps of all fields were re-optimized and the plan dose was subsequently re-calculated. When final plan arrived, the dose statistics were calculated from both plans and compared. For planned target volume (PTV), the dose for 95% volume is up to 10% higher in plans using the automated method than those using the manual method. For critical organs, an average decrease of the plan dose was achieved. However, the automated method cannot improve the plan dose for some critical organs due to limitations of the inference rules currently employed. For normal tissue, there was no significant difference between plan doses achieved by either automated or manual method. With the application of AI-guided method, the basic parameter adjustment task can be accomplished automatically and a comparable plan dose was achieved in comparison with that achieved by the manual method. Future improvements to incorporate case-specific inference rules are essential to fully automate the inverse planning process.
Hosseini, Mohammad-Parsa; Nazem-Zadeh, Mohammad-Reza; Pompili, Dario; Jafari-Khouzani, Kourosh; Elisevich, Kost; Soltanian-Zadeh, Hamid
2016-01-01
Segmentation of the hippocampus from magnetic resonance (MR) images is a key task in the evaluation of mesial temporal lobe epilepsy (mTLE) patients. Several automated algorithms have been proposed although manual segmentation remains the benchmark. Choosing a reliable algorithm is problematic since structural definition pertaining to multiple edges, missing and fuzzy boundaries, and shape changes varies among mTLE subjects. Lack of statistical references and guidance for quantifying the reliability and reproducibility of automated techniques has further detracted from automated approaches. The purpose of this study was to develop a systematic and statistical approach using a large dataset for the evaluation of automated methods and establish a method that would achieve results better approximating those attained by manual tracing in the epileptogenic hippocampus. A template database of 195 (81 males, 114 females; age range 32-67 yr, mean 49.16 yr) MR images of mTLE patients was used in this study. Hippocampal segmentation was accomplished manually and by two well-known tools (FreeSurfer and hammer) and two previously published methods developed at their institution [Automatic brain structure segmentation (ABSS) and LocalInfo]. To establish which method was better performing for mTLE cases, several voxel-based, distance-based, and volume-based performance metrics were considered. Statistical validations of the results using automated techniques were compared with the results of benchmark manual segmentation. Extracted metrics were analyzed to find the method that provided a more similar result relative to the benchmark. Among the four automated methods, ABSS generated the most accurate results. For this method, the Dice coefficient was 5.13%, 14.10%, and 16.67% higher, Hausdorff was 22.65%, 86.73%, and 69.58% lower, precision was 4.94%, -4.94%, and 12.35% higher, and the root mean square (RMS) was 19.05%, 61.90%, and 65.08% lower than LocalInfo, FreeSurfer, and hammer, respectively. The Bland-Altman similarity analysis revealed a low bias for the ABSS and LocalInfo techniques compared to the others. The ABSS method for automated hippocampal segmentation outperformed other methods, best approximating what could be achieved by manual tracing. This study also shows that four categories of input data can cause automated segmentation methods to fail. They include incomplete studies, artifact, low signal-to-noise ratio, and inhomogeneity. Different scanner platforms and pulse sequences were considered as means by which to improve reliability of the automated methods. Other modifications were specially devised to enhance a particular method assessed in this study.
Hosseini, Mohammad-Parsa; Nazem-Zadeh, Mohammad-Reza; Pompili, Dario; Jafari-Khouzani, Kourosh; Elisevich, Kost; Soltanian-Zadeh, Hamid
2016-01-01
Purpose: Segmentation of the hippocampus from magnetic resonance (MR) images is a key task in the evaluation of mesial temporal lobe epilepsy (mTLE) patients. Several automated algorithms have been proposed although manual segmentation remains the benchmark. Choosing a reliable algorithm is problematic since structural definition pertaining to multiple edges, missing and fuzzy boundaries, and shape changes varies among mTLE subjects. Lack of statistical references and guidance for quantifying the reliability and reproducibility of automated techniques has further detracted from automated approaches. The purpose of this study was to develop a systematic and statistical approach using a large dataset for the evaluation of automated methods and establish a method that would achieve results better approximating those attained by manual tracing in the epileptogenic hippocampus. Methods: A template database of 195 (81 males, 114 females; age range 32–67 yr, mean 49.16 yr) MR images of mTLE patients was used in this study. Hippocampal segmentation was accomplished manually and by two well-known tools (FreeSurfer and hammer) and two previously published methods developed at their institution [Automatic brain structure segmentation (ABSS) and LocalInfo]. To establish which method was better performing for mTLE cases, several voxel-based, distance-based, and volume-based performance metrics were considered. Statistical validations of the results using automated techniques were compared with the results of benchmark manual segmentation. Extracted metrics were analyzed to find the method that provided a more similar result relative to the benchmark. Results: Among the four automated methods, ABSS generated the most accurate results. For this method, the Dice coefficient was 5.13%, 14.10%, and 16.67% higher, Hausdorff was 22.65%, 86.73%, and 69.58% lower, precision was 4.94%, −4.94%, and 12.35% higher, and the root mean square (RMS) was 19.05%, 61.90%, and 65.08% lower than LocalInfo, FreeSurfer, and hammer, respectively. The Bland–Altman similarity analysis revealed a low bias for the ABSS and LocalInfo techniques compared to the others. Conclusions: The ABSS method for automated hippocampal segmentation outperformed other methods, best approximating what could be achieved by manual tracing. This study also shows that four categories of input data can cause automated segmentation methods to fail. They include incomplete studies, artifact, low signal-to-noise ratio, and inhomogeneity. Different scanner platforms and pulse sequences were considered as means by which to improve reliability of the automated methods. Other modifications were specially devised to enhance a particular method assessed in this study. PMID:26745947
Comparison between rotary and manual instrumentation in primary teeth.
Crespo, S; Cortes, O; Garcia, C; Perez, L
2008-01-01
The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.
Ergonomic Evaluation of Battery Powered Portable Cotton Picker
NASA Astrophysics Data System (ADS)
Dixit, A.; Manes, G. S.; Singh, A.; Prakash, A.; Mahal, J. S.
2012-09-01
Ergonomic evaluation of battery powered portable manual cotton picker was carried out on two subjects for three cotton varieties and was compared against manual method of picking. It is a hand operated machine and has a pair of chain with small sharp edged teeth and sprockets and is operated by a light weight 12 V battery. Cotton gets entangled with the chain and is collected and guided into the collection bag. Average heart rate, oxygen consumption, workload, energy expenditure was more in case of cotton picking by manual cotton picker as compared to manual picking for both the subjects for all three cotton variety types. Oxygen consumption varied from 0.81 to 0.97 l/min, workload varied from 36.32 to 46.16 W and energy expenditure varied from 16.83 to 20.33 kJ/min for both the subject in case of machine picking for all three cotton varieties. The maximum discomfort experienced by the subjects during picking cotton by manual cotton picker was in right wrist palm, right forearm, upper and lower back, left shoulder and in lower legs and both feet.
Comparison of alternative devices to determine aggregate shape.
DOT National Transportation Integrated Search
2005-01-01
This study compared devices (with corresponding procedures) that may be used to classify flat and elongated (F&E) particle content for coarse aggregate sources. The comparison involved the traditional (and manual) proportional caliper and two digital...
Gaburro, Julie; Duchemin, Jean-Bernard; Paradkar, Prasad N; Nahavandi, Saeid; Bhatti, Asim
2016-11-18
Widespread in the tropics, the mosquito Aedes aegypti is an important vector of many viruses, posing a significant threat to human health. Vector monitoring often requires fecundity estimation by counting eggs laid by female mosquitoes. Traditionally, manual data analyses have been used but this requires a lot of effort and is the methods are prone to errors. An easy tool to assess the number of eggs laid would facilitate experimentation and vector control operations. This study introduces a built-in software called ICount allowing automatic egg counting of the mosquito vector, Aedes aegypti. ICount egg estimation compared to manual counting is statistically equivalent, making the software effective for automatic and semi-automatic data analysis. This technique also allows rapid analysis compared to manual methods. Finally, the software has been used to assess p-cresol oviposition choices under laboratory conditions in order to test the system with different egg densities. ICount is a powerful tool for fast and precise egg count analysis, freeing experimenters from manual data processing. Software access is free and its user-friendly interface allows easy use by non-experts. Its efficiency has been tested in our laboratory with oviposition dual choices of Aedes aegypti females. The next step will be the development of a mobile application, based on the ICount platform, for vector monitoring surveys in the field.
NASA Astrophysics Data System (ADS)
Wang, Jingli; Liu, Xulin; Yang, Xihua; Lei, Ming; Ruan, Shunxian; Nie, Kai; Miao, Yupeng; Liu, Jincheng
2014-04-01
Visibility information is fundamental in aviation, navigation, land transportation, air quality and dust storm monitoring, and military activities which often require frequent and accurate real-time observation of visibility. The traditional manual observation, the primary means to obtain visibility information by human eyes, is subjective, inconsistent and costly. Instrumental observation (or traditional optical instrument) has overcome some of these limitations, but it is difficult to obtain correct visibility information in a complicated atmospheric (e.g. rainy and foggy) environment. We developed a new visibility instrument, digital photography visiometer system (DPVS), equipped with advanced digital photographic technology including high-resolution charge-coupled-device camera and computer. The new DPVS imitates the human eye observation and accurately calculates the visibility based on its definition and observational principles. We compared the results of the new DPVS with those from a forward scattering visibility instrument (FD12) and manual visibility observations in various (rainy, non-rainy, foggy) weather conditions. The comparative results show that the new DPVS, FD12, and manual observation have the same trend of change, but the observation from the new DPVS is closer to that from the manual observations in rainy days or complicated weather conditions. Our study demonstrates that the new DVPS is superior to the optical visibility instrument and can be used for automated visibility observations under all weather conditions.
Comparison of manual and automatic MR‐CT registration for radiotherapy of prostate cancer
Carl, Jesper; Østergaard, Lasse Riis
2016-01-01
In image‐guided radiotherapy (IGRT) of prostate cancer, delineation of the clinical target volume (CTV) often relies on magnetic resonance (MR) because of its good soft‐tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR‐CT registration of the prostate has previously been developed using a voxel property‐based registration as an alternative to a manual landmark‐based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni‐Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80 mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration. PACS number(s): 87.57.nj, 87.61.‐c, 87.57.Q‐, 87.56.J‐ PMID:27167285
Lim, Hong-Chul; Yoon, Yong-Cheol; Wang, Joon-Ho; Bae, Ji-Hoon
2012-12-01
The purpose of this study was to compare the initial stability of anatomical and non-anatomical single bundle anterior cruciate ligament (ACL) reconstruction and to determine which would better restore intact knee kinematics. Our hypothesis was that the initial stability of anatomical single bundle ACL reconstruction would be superior to that of non-anatomical single bundle ACL reconstruction. Anterior tibial translation (ATT) and internal rotation of the tibia were measured with a computer navigation system in seven pairs of fresh-frozen cadaveric knees under two testing conditions (manual maximum anterior force, and a manual maximum anterior force combined with an internal rotational force). Tests were performed at 0, 30, 60, and 90 degrees of flexion with the ACL intact, the ACL transected, and after reconstruction of one side of a pair with either anatomical or non-anatomical single bundle ACL reconstruction. Under manual maximal anterior force, both reconstruction techniques showed no significant difference of ATT when compared to ACL intact knee state at 30° of knee flexion (p > 0.05). Under the combined anterior and internal rotatory force, non-anatomical single-bundle ACL reconstruction showed significant difference of ATT compared to those in ACL intact group (p < 0.05). In contrast, central anatomical single bundle ACL reconstruction showed no significant difference of ATT compared to those in ACL intact group (p > 0.05). Internal rotation of the tibia showed no significant difference in the ACL intact, the ACL transected, non-anatomical reconstructed and anatomical reconstructed knees. Anatomical single bundle ACL reconstruction restored the initial stability closer to the native ACL under combined anterior and internal rotational forces when compared to non-anatomical ACL single bundle reconstruction.
Effects of vibratory stimulation on sexual response in women with spinal cord injury.
Sipski, Marca L; Alexander, Craig J; Gomez-Marin, Orlando; Grossbard, Marissa; Rosen, Raymond
2005-01-01
Women with spinal cord injuries (SCIs) have predictable alterations in sexual responses. They commonly have a decreased ability to achieve genital sexual arousal. This study determined whether the use of vibratory stimulation would result in increased genital arousal as measured by vaginal pulse amplitude in women with SCIs. Subjects included 46 women with SCIs and 11 nondisabled control subjects. Results revealed vibratory clitoral stimulation resulted in increased vaginal pulse amplitude as compared with manual clitoral stimulation in both SCI and nondisabled subjects; however, these differences were not statistically significant. Subjective levels of arousal were also compared between SCI and nondisabled control subjects. Both vibratory and manual clitoral stimulation resulted in significantly increased arousal levels in both groups of subjects; however, statistically significant differences between the two conditions were only noted in nondisabled subjects. Further studies of the effects of repetitive vibratory stimulation are underway.
The timing of exposure in clinic-based treatment for childhood anxiety disorders.
Gryczkowski, Michelle R; Tiede, Michael S; Dammann, Julie E; Jacobsen, Amy Brown; Hale, Lisa R; Whiteside, Stephen P H
2013-03-01
The present study examines treatment length and timing of exposure from two child anxiety disorders clinics. Data regarding symptoms and treatment characteristics for 28 youth were prospectively obtained through self, parent, and therapist report at each session. Information regarding length of treatment, timing of exposure initiation, and drop-out rates were compared with those obtained through efficacy and effectiveness trials of manualized treatment for anxious youth. Findings from the authors' clinical data revealed significantly shorter treatment duration with exposures implemented sooner than in the previous studies. Dropout rates were significantly higher than in the efficacy trial but comparable with the effectiveness trial. Outcome data from a subset of eight patients revealed large effect sizes. These findings suggest that effective treatment can be shorter and more focused on exposure than is often outlined in manuals and have important implications for outcome research and dissemination.
Woodhouse, Marjolein; Worsley, Peter R; Voegeli, David; Schoonhoven, Lisette; Bader, Dan L
2015-02-01
Individuals who have reduced mobility are at risk of developing pressure ulcers if they are subjected to sustained static postures. To reduce this risk, clinical guidelines advocate healthcare professionals reposition patients regularly. Automated tilting mechanisms have recently been introduced to provide periodic repositioning. This study compared the performance of such a prototype mattress to conventional manual repositioning. Ten healthy participants (7 male and 3 female, aged 23-66 years) were recruited to compare the effects of an automated tilting mattress to standard manual repositioning, using the 30° tilt. Measures during the tilting protocols (supine, right and left tilt) included comfort and safety scores, interface pressures, inclinometer angles and transcutaneous gas tensions (sacrum and shoulder). Data from these outcomes were compared between each protocol. Results indicated no significant differences for either interface pressures or transcutaneous gas responses between the two protocols (P>0.05 in both cases). Indeed a small proportion of participants (~30%) exhibited changes in transcutaneous oxygen and carbon dioxide values in the shoulder during a right tilt for both protocols. The tilt angles at the sternum and the pelvis were significantly less in the automated tilt compared to the manual tilt (mean difference=9.4-11.5°, P<0.001). Participants reported similar comfort scores for both protocols, although perceived safety was reduced on the prototype mattress. Although further studies are required to assess its performance in maintaining tissue viability, an automated tilting mattress offers the ability to periodically reposition vulnerable individuals, with potential economic savings to health services. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ozyurek, Taha; Ozsezer-Demiryurek, Ebru
2017-01-01
The aim of this study was to compare the cleanliness of root canal walls after retreatment using ProTaper Next (PTN), ProTaper Universal Retreatment (PTR) nickel-titanium (NiTi) systems and Hedström hand files in curved mesial canals of mandibular molar teeth and the time required for gutta-percha and sealer removal. Ninety mandibular molar teeth with curved mesial roots were instrumented up to #35.04 with Mtwo NiTi rotary instruments and obturated using the continuous wave of condensation technique. Removal of gutta-percha and sealer was performed using one of the following: PTN and PTR NiTi systems and Hedström hand files. Samples were placed on the VistaScan phosphor plates in the mesio-distal direction and the radiographs were taken. The digital radiographs were analyzed using AutoCAD software. Also, the total time required for gutta-percha removal was calculated by a chronometer. The total retreatment time was significantly shorter in the PTN and PTR groups compared with the manual group (p<0.05). There was a significant difference between the groups according to the total residual gutta-percha and sealer (p<0.05). The PTN and PTR groups left significantly less gutta-percha and sealer remnant than the manual group (p<0.001). Within the limitations of this study, the PTN and PTR groups showed less residual gutta-percha and sealer than the manual group. The NiTi rotary systems were significantly faster than the manual group in the time required for gutta-percha and sealer removal.
Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo
2016-01-01
The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.
Improved segmentation of cerebellar structures in children
Narayanan, Priya Lakshmi; Boonazier, Natalie; Warton, Christopher; Molteno, Christopher D; Joseph, Jesuchristopher; Jacobson, Joseph L; Jacobson, Sandra W; Zöllei, Lilla; Meintjes, Ernesta M
2016-01-01
Background Consistent localization of cerebellar cortex in a standard coordinate system is important for functional studies and detection of anatomical alterations in studies of morphometry. To date, no pediatric cerebellar atlas is available. New method The probabilistic Cape Town Pediatric Cerebellar Atlas (CAPCA18) was constructed in the age-appropriate National Institute of Health Pediatric Database asymmetric template space using manual tracings of 16 cerebellar compartments in 18 healthy children (9–13 years) from Cape Town, South Africa. The individual atlases of the training subjects were also used to implement multi atlas label fusion using multi atlas majority voting (MAMV) and multi atlas generative model (MAGM) approaches. Segmentation accuracy in 14 test subjects was compared for each method to ‘gold standard’ manual tracings. Results Spatial overlap between manual tracings and CAPCA18 automated segmentation was 73% or higher for all lobules in both hemispheres, except VIIb and X. Automated segmentation using MAGM yielded the best segmentation accuracy over all lobules (mean Dice Similarity Coefficient 0.76; range 0.55–0.91). Comparison with existing methods In all lobules, spatial overlap of CAPCA18 segmentations with manual tracings was similar or higher than those obtained with SUIT (spatially unbiased infra-tentorial template), providing additional evidence of the benefits of an age appropriate atlas. MAGM segmentation accuracy was comparable to values reported recently by Park et al. (2014) in adults (across all lobules mean DSC = 0.73, range 0.40–0.89). Conclusions CAPCA18 and the associated multi atlases of the training subjects yield improved segmentation of cerebellar structures in children. PMID:26743973
Höink, Anna Janina; Schülke, Christoph; Koch, Raphael; Löhnert, Annika; Kammerer, Sara; Fortkamp, Rasmus; Heindel, Walter; Buerke, Boris
2017-11-01
Purpose To compare measurement precision and interobserver variability in the evaluation of hepatocellular carcinoma (HCC) and liver metastases in MSCT before and after transarterial local ablative therapies. Materials and Methods Retrospective study of 72 patients with malignant liver lesions (42 metastases; 30 HCCs) before and after therapy (43 SIRT procedures; 29 TACE procedures). Established (LAD; SAD; WHO) and vitality-based parameters (mRECIST; mLAD; mSAD; EASL) were assessed manually and semi-automatically by two readers. The relative interobserver difference (RID) and intraclass correlation coefficient (ICC) were calculated. Results The median RID for vitality-based parameters was lower from semi-automatic than from manual measurement of mLAD (manual 12.5 %; semi-automatic 3.4 %), mSAD (manual 12.7 %; semi-automatic 5.7 %) and EASL (manual 10.4 %; semi-automatic 1.8 %). The difference in established parameters was not statistically noticeable (p > 0.05). The ICCs of LAD (manual 0.984; semi-automatic 0.982), SAD (manual 0.975; semi-automatic 0.958) and WHO (manual 0.984; semi-automatic 0.978) are high, both in manual and semi-automatic measurements. The ICCs of manual measurements of mLAD (0.897), mSAD (0.844) and EASL (0.875) are lower. This decrease cannot be found in semi-automatic measurements of mLAD (0.997), mSAD (0.992) and EASL (0.998). Conclusion Vitality-based tumor measurements of HCC and metastases after transarterial local therapies should be performed semi-automatically due to greater measurement precision, thus increasing the reproducibility and in turn the reliability of therapeutic decisions. Key points · Liver lesion measurements according to EASL and mRECIST are more precise when performed semi-automatically.. · The higher reproducibility may facilitate a more reliable classification of therapy response.. · Measurements according to RECIST and WHO offer equivalent precision semi-automatically and manually.. Citation Format · Höink AJ, Schülke C, Koch R et al. Response Evaluation of Malignant Liver Lesions After TACE/SIRT: Comparison of Manual and Semi-Automatic Measurement of Different Response Criteria in Multislice CT. Fortschr Röntgenstr 2017; 189: 1067 - 1075. © Georg Thieme Verlag KG Stuttgart · New York.
Setälä, Piritta Anniina; Virkkunen, Ilkka Tapani; Kämäräinen, Antti Jaakko; Huhtala, Heini Sisko Annamari; Virta, Janne Severi; Yli-Hankala, Arvi Mikael; Hoppu, Sanna Elisa
2018-05-16
Active compression-decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO 2 ) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO 2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts. 10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO 2 values were collected continuously with the defibrillator. Differences in ETCO 2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO 2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases. Mean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO 2 output, the interaction between the method and the patient was significant (P<0.001). ETCO 2 output was higher with manual CPR in 6 of the 10 cases. This study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO 2 is used as a quantitative measure of CPR effectiveness. NCT00951704; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DSM-5 ASD moves forward into the past.
Tsai, Luke Y; Ghaziuddin, Mohammad
2014-02-01
The fifth edition of the diagnostic and statistical manual of mental disorders (DSM-5) (APA in diagnostic and statistical manual of mental disorders, Author, Washington, 2013) has decided to merge the subtypes of pervasive developmental disorders into a single category of autism spectrum disorder (ASD) on the assumption that they cannot be reliably differentiated from one another. The purpose of this review is to analyze the basis of this assumption by examining the comparative studies between Asperger's disorder (AsD) and autistic disorder (AD), and between pervasive developmental disorder not otherwise specified (PDDNOS) and AD. In all, 125 studies compared AsD with AD. Of these, 30 studies concluded that AsD and AD were similar conditions while 95 studies found quantitative and qualitative differences between them. Likewise, 37 studies compared PDDNOS with AD. Nine of these concluded that PDDNOS did not differ significantly from AD while 28 reported quantitative and qualitative differences between them. Taken together, these findings do not support the conceptualization of AD, AsD and PDDNOS as a single category of ASD. Irrespective of the changes proposed by the DSM-5, future research and clinical practice will continue to find ways to meaningfully subtype the ASD.
Zwahlen, Marcel; Wells, Jonathan C.; Bender, Nicole; Henneberg, Maciej
2017-01-01
Background Manual anthropometric measurements are time-consuming and challenging to perform within acceptable intra- and inter-individual error margins in large studies. Three-dimensional (3D) laser body scanners provide a fast and precise alternative: within a few seconds the system produces a 3D image of the body topography and calculates some 150 standardised body size measurements. Objective The aim was to enhance the small number of existing validation studies and compare scan and manual techniques based on five selected measurements. We assessed the agreement between two repeated measurements within the two methods, analysed the direct agreement between the two methods, and explored the differences between the techniques when used in regressions assessing the effect of health related determinants on body shape indices. Methods We performed two repeated body scans on 123 volunteering young men using a Vitus Smart XXL body scanner. We manually measured height, waist, hip, buttock, and chest circumferences twice for each participant according to the WHO guidelines. The participants also filled in a basic questionnaire. Results Mean differences between the two scan measurements were smaller than between the two manual measurements, and precision as well as intra-class correlation coefficients were higher. Both techniques were strongly correlated. When comparing means between both techniques we found significant differences: Height was systematically shorter by 2.1 cm, whereas waist, hip and bust circumference measurements were larger in the scans by 1.17–4.37 cm. In consequence, body shape indices also became larger and the prevalence of overweight was greater when calculated from the scans. Between 4.1% and 7.3% of the probands changed risk category from normal to overweight when classified based on the scans. However, when employing regression analyses the two measurement techniques resulted in very similar coefficients, confidence intervals, and p-values. Conclusion For performing a large number of measurements in a large group of probands in a short time, body scans generally showed good feasibility, reliability, and validity in comparison to manual measurements. The systematic differences between the methods may result from their technical nature (contact vs. non-contact). PMID:28289559
Multi-Case Knowledge-Based IMRT Treatment Planning in Head and Neck Cancer
NASA Astrophysics Data System (ADS)
Grzetic, Shelby Mariah
Head and neck cancer (HNC) IMRT treatment planning is a challenging process that relies heavily on the planner's experience. Previously, we used the single, best match from a library of manually planned cases to semi-automatically generate IMRT plans for a new patient. The current multi-case Knowledge Based Radiation Therapy (MC-KBRT) study utilized different matching cases for each of six individual organs-at-risk (OARs), then combined those six cases to create the new treatment plan. From a database of 103 patient plans created by experienced planners, MC-KBRT plans were created for 40 (17 unilateral and 23 bilateral) HNC "query" patients. For each case, 2D beam's-eye-view images were used to find similar geometric "match" patients separately for each of 6 OARs. Dose distributions for each OAR from the 6 matching cases were combined and then warped to suit the query case's geometry. The dose-volume constraints were used to create the new query treatment plan without the need for human decision-making throughout the IMRT optimization. The optimized MC-KBRT plans were compared against the clinically approved plans and Version 1 (previous KBRT using only one matching case with dose warping) using the dose metrics: mean, median, and maximum (brainstem and cord+5mm) doses. Compared to Version 1, MC-KBRT had no significant reduction of the dose to any of the OARs in either unilateral or bilateral cases. Compared to the manually planned unilateral cases, there was significant reduction of the oral cavity mean/median dose (>2Gy) at the expense of the contralateral parotid. Compared to the manually planned bilateral cases, reduction of dose was significant in the ipsilateral parotid, larynx, and oral cavity (>3Gy mean/median) while maintaining PTV coverage. MC-KBRT planning in head and neck cancer generates IMRT plans with better dose sparing than manually created plans. MC-KBRT using multiple case matches does not show significant dose reduction compared to using a single match case with dose warping.
Effects of Retinal Eccentricity on Human Manual Control
NASA Technical Reports Server (NTRS)
Popovici, Alexandru; Zaal, Peter M. T.
2017-01-01
This study investigated the effects of viewing a primary flight display at different retinal eccentricities on human manual control behavior and performance. Ten participants performed a pitch tracking task while looking at a simplified primary flight display at different horizontal and vertical retinal eccentricities, and with two different controlled dynamics. Tracking performance declined at higher eccentricity angles and participants behaved more nonlinearly. The visual error rate gain increased with eccentricity for single-integrator-like controlled dynamics, but decreased for double-integrator-like dynamics. Participants' visual time delay was up to 100 ms higher at the highest horizontal eccentricity compared to foveal viewing. Overall, vertical eccentricity had a larger impact than horizontal eccentricity on most of the human manual control parameters and performance. Results might be useful in the design of displays and procedures for critical flight conditions such as in an aerodynamic stall.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys. PMID:27585631
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Joe H.; University of Melbourne, Victoria; Lim Joon, Daryl
2015-06-01
Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified onmore » prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.« less
Norman, Berk; Pedoia, Valentina; Majumdar, Sharmila
2018-03-27
Purpose To analyze how automatic segmentation translates in accuracy and precision to morphology and relaxometry compared with manual segmentation and increases the speed and accuracy of the work flow that uses quantitative magnetic resonance (MR) imaging to study knee degenerative diseases such as osteoarthritis (OA). Materials and Methods This retrospective study involved the analysis of 638 MR imaging volumes from two data cohorts acquired at 3.0 T: (a) spoiled gradient-recalled acquisition in the steady state T1 ρ -weighted images and (b) three-dimensional (3D) double-echo steady-state (DESS) images. A deep learning model based on the U-Net convolutional network architecture was developed to perform automatic segmentation. Cartilage and meniscus compartments were manually segmented by skilled technicians and radiologists for comparison. Performance of the automatic segmentation was evaluated on Dice coefficient overlap with the manual segmentation, as well as by the automatic segmentations' ability to quantify, in a longitudinally repeatable way, relaxometry and morphology. Results The models produced strong Dice coefficients, particularly for 3D-DESS images, ranging between 0.770 and 0.878 in the cartilage compartments to 0.809 and 0.753 for the lateral meniscus and medial meniscus, respectively. The models averaged 5 seconds to generate the automatic segmentations. Average correlations between manual and automatic quantification of T1 ρ and T2 values were 0.8233 and 0.8603, respectively, and 0.9349 and 0.9384 for volume and thickness, respectively. Longitudinal precision of the automatic method was comparable with that of the manual one. Conclusion U-Net demonstrates efficacy and precision in quickly generating accurate segmentations that can be used to extract relaxation times and morphologic characterization and values that can be used in the monitoring and diagnosis of OA. © RSNA, 2018 Online supplemental material is available for this article.
Jain, Yashika
2013-01-01
Background Plaque is intimately related to the production and progress of dental caries and inflammatory gingival and periodontal diseases. Good plaque control facilitates the return to health for patients with gingival and periodontal diseases. Daily use of a toothbrush and other oral hygiene aids is the most dependable way to achieve oral health benefits for all patients. Methods A randomized clinical trial was conducted to compare the efficacy of a powered toothbrush with a manual toothbrush in controlling plaque and gingivitis over a 6-week period. The sample consisted of 60 dental students of both sexes, with ages ranging from 18 to 28 years. The samples were stratified and randomly divided into two groups of 30 by a second examiner using the coin toss method; one group used a manual toothbrush and the other group used a powered toothbrush. Each participant’s gingival index, plaque index and oral hygiene index were assessed on the seventh, 14th, and 45th days on the basis of the assigned toothbrush. Collected data were analyzed and different subgroups were compared using Student’s t-test. Results A paired t-test revealed a highly significant reduction in the gingival, plaque, and oral hygiene index scores of the manual and powered groups at the first, second, and sixth weeks (P-value < 0.0001). An unpaired t-test revealed a significant reduction between the plaque index scores of the manual and powered groups at the second week (P-value < 0.05). Another unpaired t-test revealed a highly significant reduction between the plaque index scores of the manual and powered groups at the sixth week (P-value < 0.0001). Conclusion The subject group using the powered toothbrush demonstrated clinical and statistical improvement in overall plaque scores. Powered toothbrushes offer an individual the ability to brush the teeth in a way that is optimal in terms of removing plaque and improving gingival health, conferring good brushing technique on all who use them, irrespective of manual dexterity or training. PMID:23674927
Jamema, Swamidas V; Kirisits, Christian; Mahantshetty, Umesh; Trnkova, Petra; Deshpande, Deepak D; Shrivastava, Shyam K; Pötter, Richard
2010-12-01
Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK(O/T)) was used to compare the loading patterns. The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2) cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p=0.35, 0.38, 0.4). Dose to bladder (7.8±1.6 Gy) and sigmoid (5.6±1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1±1.7 Gy p=0.006) and sigmoid (4.5±1.0 Gy p=0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5±1.4 Gy, p=0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04) cGy m(-2) for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK(O/T) was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Meta-Analysis of the Minimalist Training Model
ERIC Educational Resources Information Center
Ginns, Paul; Hollender, Nina; Reimann, Peter
2006-01-01
This article reviews research on the Minimalist instructional design model, a learner-centred approach to the design of instructional materials such as computer program manuals or on-line help. Studies in this paradigm have typically compared minimalist materials against traditional "system-centred" materials. Additionally, some studies have…
Cho, Jae Ho; Lee, Doo Hyung; Song, Hyung Keun; Bang, Joon Young; Lee, Kyung Tai; Park, Young Uk
2016-04-01
Clinicians frequently diagnose chronic ankle instability using the manual anterior drawer test and stress radiography. However, both examinations can yield incorrect results and do not reveal the extent of ankle instability. Stress ultrasound has been reported to be a new diagnostic tool for the diagnosis of chronic ankle instability. The purpose of this study was to assess the diagnostic value of stress ultrasound for chronic ankle instability compared to the manual anterior drawer test, stress radiography, magnetic resonance imaging (MRI), and arthroscopy. Twenty-eight consecutive patients who underwent ankle arthroscopy and subsequent modified Broström repair for treatment of chronic ankle instability were included. The arthroscopic findings were used as the reference standard. A standardized physical examination (manual anterior drawer test), stress radiography, MRI, and stress ultrasound were performed to assess the anterior talofibular ligament (ATFL) prior to operation. Ultrasound images were taken in the resting position and the maximal anterior drawer position. Grade 3 lateral instability was verified arthroscopically in all 28 cases with a clinical diagnosis (100%). Twenty-two cases showed grade III instability on the manual anterior drawer test (78.6%). Twenty-four cases displayed anterior translation exceeding 5 mm on stress radiography (86%), and talar tilt angle exceeded 15° in three cases (11 %). Nineteen cases displayed a partial chronic tear (change in thickness or signal intensity), and nine cases displayed complete tear on MRI (100%). Lax and wavy ATFL was evident on stress ultrasound in all cases (100 %). The mean value of the ATFL length was 2.8 ± 0.3 cm for the stressed condition and 2.1 ± 0.2 cm for the resting condition (p < 0.001). Stress ultrasound may be useful for the diagnosis of chronic ankle instability in addition to the manual anterior drawer test and stress radiography. III.
Iori, Michele; Capponi, Pier C; Rubagotti, Sara; Esposizione, Luca Rosario; Seemann, Johanna; Pitzschler, Riccardo; Dreger, Thorsten; Formisano, Debora; Grassi, Elisa; Fioroni, Federica; Versari, Annibale; Asti, Mattia
2017-01-01
In spite of the hazard due to the radiation exposure, preparation of 90 Y- and 177 Lu-labelled radiopharmaceuticals is still mainly performed using manual procedures. In the present study the performance of a commercial automatic synthesizer based on disposable cassettes for the labelling of 177 Lu- and 90 Y-DOTA-conjugated biomolecules (namely, DOTATOC and PSMA-617) was evaluated and compared to a manual and a semiautomated approach. The dose exposure of the operators was evaluated as well. More than 300 clinical preparations of both 90 Y- and 177 Lu-labelled radiopharmaceuticals have been performed using the three different methods. The mean radiochemical yields for 90 Y-DOTATOC were 96.2 ± 4.9%, 90.3 ± 5.6%, and 82.0 ± 8.4%, while for 177 Lu-DOTATOC they were 98.3% ± 0.6, 90.8% ± 8.3, and 83.1 ± 5.7% when manual, semiautomated, and automated approaches were used, respectively. The mean doses on the whole hands for yttrium-90 preparations were 0.15 ± 0.4 mSv/GBq, 0.04 ± 0.1 mSv/GBq, and 0.11 ± 0.3 mSv/GBq for manual, semiautomated, and automated synthesis, respectively, and for lutetium-177 preparations, they were 0.02 ± 0.008 mSv/GBq, 0.01 ± 0.03 mSv/GBq, and 0.01 ± 0.02 mSv/GBq, respectively. In conclusion, the automated approach guaranteed reliable and reproducible preparations of pharmaceutical grade therapeutic radiopharmaceuticals in a decent RCY. The radiation exposure of the operators remained comparable to the manual approach mainly due to the fact that a dedicated shielding was still not available for the system.
Lee, E C; Rafiq, A; Merrell, R; Ackerman, R; Dennerlein, J T
2005-08-01
Minimally invasive surgical techniques expose surgeons to a variety of occupational hazards that may promote musculoskeletal disorders. Telerobotic systems for minimally invasive surgery may help to reduce these stressors. The objective of this study was to compare manual and telerobotic endoscopic surgery in terms of postural and mental stress. Thirteen participants with no experience as primary surgeons in endoscopic surgery performed a set of simulated surgical tasks using two different techniques--a telerobotic master--slave system and a manual endoscopic surgery system. The tasks consisted of passing a soft spherical object through a series of parallel rings, suturing along a line 5-cm long, running a 32-in ribbon, and cannulation. The Job Strain Index (JSI) and Rapid Upper Limb Assessment (RULA) were used to quantify upper extremity exposure to postural and force risk factors. Task duration was quantified in seconds. A questionnaire provided measures of the participants' intuitiveness and mental stress. The JSI and RULA scores for all four tasks were significantly lower for the telerobotic technique than for the manual one. Task duration was significantly longer for telerobotic than for manual tasks. Participants reported that the telerobotic technique was as intuitive as, and no more stressful than, the manual technique. Given identical tasks, the time to completion is longer using the telerobotic technique than its manual counterpart. For the given simulated tasks in the laboratory setting, the better scores for the upper extremity postural analysis indicate that telerobotic surgery provides a more comfortable environment for the surgeon without any additional mental stress.
Boers, A M; Marquering, H A; Jochem, J J; Besselink, N J; Berkhemer, O A; van der Lugt, A; Beenen, L F; Majoie, C B
2013-08-01
Cerebral infarct volume as observed in follow-up CT is an important radiologic outcome measure of the effectiveness of treatment of patients with acute ischemic stroke. However, manual measurement of CIV is time-consuming and operator-dependent. The purpose of this study was to develop and evaluate a robust automated measurement of the CIV. The CIV in early follow-up CT images of 34 consecutive patients with acute ischemic stroke was segmented with an automated intensity-based region-growing algorithm, which includes partial volume effect correction near the skull, midline determination, and ventricle and hemorrhage exclusion. Two observers manually delineated the CIV. Interobserver variability of the manual assessments and the accuracy of the automated method were evaluated by using the Pearson correlation, Bland-Altman analysis, and Dice coefficients. The accuracy was defined as the correlation with the manual assessment as a reference standard. The Pearson correlation for the automated method compared with the reference standard was similar to the manual correlation (R = 0.98). The accuracy of the automated method was excellent with a mean difference of 0.5 mL with limits of agreement of -38.0-39.1 mL, which were more consistent than the interobserver variability of the 2 observers (-40.9-44.1 mL). However, the Dice coefficients were higher for the manual delineation. The automated method showed a strong correlation and accuracy with the manual reference measurement. This approach has the potential to become the standard in assessing the infarct volume as a secondary outcome measure for evaluating the effectiveness of treatment.
Model surgery with a passive robot arm for orthognathic surgery planning.
Theodossy, Tamer; Bamber, Mohammad Anwar
2003-11-01
The aims of the study were to assess the degree of accuracy of model surgery performed manually using the Eastman technique and to compare it with model surgery performed with the aid of a robot arm. Twenty-one patients undergoing orthognathic surgery gave consent for this study. They were divided into 2 groups based on the model surgery technique used. Group A (52%) had model surgery performed manually, whereas group B (48%) had their model surgery performed using the robot arm. Patients' maxillary casts were measured before and after model surgery, and results were compared with those for the original treatment plan in horizontal (x-axis), vertical (y-axis), and transverse (z-axis) planes. Statistical analysis using Mann-Whitney U test for x- and y-axis and independent sample t test for z-axis have shown significant differences between both groups in x-axis (P =.024) and y-axis (P =.01) but not in z-axis (P =.776). Model surgery performed with the aid of a robot arm is significantly more accurate in anteroposterior and vertical planes than is manual model surgery. Robot arm has an important role to play in orthognathic surgery planning and in determining the biometrics of orthognathic surgical change at the model surgery stage.
Fujimoto, S; Takahashi, M; Endoh, F; Takai, M; Kobayashi, K; Kiuchi, S; Konno, C; Obata, G; Okui, K
1991-09-01
From January 1983 to December 1989, we performed esophagojejunostomy on 379 patients who underwent total gastrectomy for gastric cancer. A mechanical EEA stapler or conventional manual suturing was used. The clinical outcomes of 199 patients in whom stapling was used (stapler group) and 180 patients in whom manual suturing was done (manual group) were compared. Two of the 199 patients in the stapler group and 3 of the 180 patients in the manual group died of causes directly related to the anastomosis. In the stapler group, 16 stapled anastomoses were formed supradiaphragmatically, and manual suturing was done for 6 patients. The highly placed anastomosis was formed without left thoracotomy or with median sternotomy in 8 of the 16 patients in whom the stapling device was used and in 1 of the 6 patients in whom manual suturing was used. The incidence of anastomotic leakage and stenosis did not differ between the groups. Thus, the mechanical stapler facilitated the construction of a rapid, reliable esophagojejunostomic anastomosis.
Bavry, Anthony A; Raymond, Russell E; Bhatt, Deepak L; Chambers, Charles E; DeNardo, Andrew J; Hermiller, James B; Myers, Paul R; Pitts, Douglas E; Scott, John A; Savader, Scott J; Steinhubl, Steven
2008-04-01
The aim of vascular closure devices is to safely secure the arterial access site at the conclusion of catheterization procedures, thereby increasing patient comfort and decreasing time to hemostasis and ambulation. The FISH (femoral introducer sheath and hemostasis) device is novel in that the access sheath and closure component are incorporated onto the same system. The FISH pivotal investigation was conducted at 8 catheterization laboratories throughout the United States. Eligible diagnostic patients were randomized (2 to 1) to the FISH device versus manual compression and assessed for time to hemostasis and time to ambulation. Half of the participants underwent ultrasonographic evaluation at 30-day follow up. Enrollment for an interventional cohort is ongoing and will be reported at a later date; however, the interventional patients enrolled to date were combined with the diagnostic patients to comprise the safety data of the trial. Overall, 191 patients were randomized to the FISH device and 106 patients to manual compression. Most patients received a 6 Fr sheath (approximately 70%), while the remaining patients received a 5 or 8 Fr sheath. Twenty-seven patients who received the FISH device were converted to manual compression due to anticipated suboptimal hemostasis. Among the diagnostic patients, the mean time to hemostasis was 8.9 minutes for the FISH device, compared to 17.2 minutes for manual compression (p < 0.0001). Similarly, the mean time to ambulation was 2.4 hours for the FISH device, compared to 4.3 hours for manual compression (p < 0.0001). Among the total cohort, there was 1 death and 1 episode of major access-site-related bleeding that required transfusion occurred in the FISH group (1.1%), compared to no serious adverse safety events in the manual compression group (p = 1.0). For the FISH group, there were 5 minor adverse safety events; 3 access-site hematomas and 2 pseudoaneurysms treated with thrombin injection, and in the manual compression group, there was 2 access-site hematomas and 1 pseudoaneurysm treated with thrombin injection (p = 1.0). Among diagnostic patients with good sheath placement and favorable femoral anatomy, the FISH device is superior in achieving time to hemostasis and ambulation compared to manual compression. At 30 days, there is no apparent difference in serious or minor adverse vascular events with the use of the FISH device.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
DOT National Transportation Integrated Search
2014-04-01
Compared to microscopic safety studies, macroscopic-focused research is more efficient at integrating zonal-level features into crash prediction models and identifying hot zones. However, macroscopic screening has accuracy limitations. Thus, this stu...
Effects of supervisory train control technology on operator attention.
DOT National Transportation Integrated Search
2005-07-31
This report describes an experiment evaluating the effects of supervisory control automation on attention allocation while operating : a train. The study compared two levels of supervisory control (partial and full) to manual control, in terms of how...
Architectural study of the design and operation of advanced force feedback manual controllers
NASA Technical Reports Server (NTRS)
Tesar, Delbert; Kim, Whee-Kuk
1990-01-01
A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.
Exponential error reduction in pretransfusion testing with automation.
South, Susan F; Casina, Tony S; Li, Lily
2012-08-01
Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.
Perceived ejaculatory latency and pleasure in different outlets.
Corty, Eric W
2008-11-01
Ejaculatory latencies have been studied in coitus and with masturbation, but not with oral or manual stimulation by a partner. The present study extended research on ejaculatory latency to these outlets, and investigated the effect of perceived pleasure on self-reported ejaculatory latency. A convenience sample of male college students, not selected for sexual dysfunction, completed questionnaires assessing the outcome measures. Self-report measures of latency to ejaculation in, and perceived pleasure associated with, four different outlets (vaginal intercourse, oral intercourse, manual stimulation by a partner, and masturbation). Ejaculatory latencies in partnered activities were predictive of each other. Masturbatory latencies were predictive of coital latencies but not oral or manual stimulation latencies; all the partnered activities were predictive of each other. There was no difference in time to ejaculation among any of the partnered outlets, although ejaculation occurred more quickly with masturbation than with coitus or manual stimulation. In terms of pleasure associated with the outlets, vaginal and oral intercourse were perceived as equally pleasurable, and both were rated as more pleasurable than manual stimulation or masturbation, which did not differ from each other. These results suggest that rapidity of ejaculation is consistent across outlets for the partnered sexual activities, and that there is little unique-in terms of ejaculatory latency--about vaginal intercourse compared with oral or manual stimulation by a partner. Masturbation, however, does differ from the partnered activities. Although the average correlation, for individuals, between latency and pleasure for the different outlets is near zero, there are subgroups of men who have (i) a negative relation, (ii) a positive relation, or (iii) no relation. Results show that men, for whom greater pleasure is associated with shorter latency, are more likely to be dissatisfied with their intravaginal ejaculatory latencies, regardless of actual latency.
Jordan, Claus; Luttmann, Alwin; Theilmeier, Andreas; Kuhn, Stefan; Wortmann, Norbert; Jäger, Matthias
2011-05-26
The human spine is often exposed to mechanical load in vocational activities especially in combination with lifting, carrying and positioning of heavy objects. This also applies in particular to nursing activities with manual patient handling. In the present study a detailed investigation on the load of the lumbar spine during manual patient handling was performed. For a total of 13 presumably endangering activities with transferring a patient, the body movements performed by healthcare workers were recorded and the exerted action forces were determined with regard to magnitude, direction and lateral distribution in the time course with a "measuring bed", a "measuring chair" and a "measuring floor". By the application of biomechanical model calculations the load on the lowest intervertebral disc of the lumbar spine (L5-S1) was determined considering the posture and action force data for every manual patient handling. The results of the investigations reveal the occurrence of high lumbar load during manual patient handling activities, especially in those cases, where awkward postures of the healthcare worker are combined with high action forces caused by the patient's mass. These findings were compared to suitable issues of corresponding investigations provided in the literature. Furthermore measurement-based characteristic values of lumbar load were derived for the use in statement procedures concerning the disease no. 2108 of the German list of occupational diseases. To protect healthcare workers from mechanical overload and the risk of developing a disc-related disease, prevention measures should be compiled. Such measures could include the application of "back-fairer" nursing techniques and the use of "technical" and" small aids" to reduce the lumbar load during manual patient handling. Further studies, concerning these aspects, are necessary.
[Social determinants of overweight and obesity in Spain in 2006].
Ortiz-Moncada, Rocio; Alvarez-Dardet, Carlos; Miralles-Bueno, Juan José; Ruíz-Cantero, María Teresa; Dal Re-Saavedra, María Angeles; Villar-Villalba, Carmen; Pérez-Farinós, Napoleón; Serra-Majem, Lluís
2011-12-10
Obesity in the Spanish adult population has almost doubled from 1987 to 2003. The aim is to update the prevalence of overweight and obesity, and reassess its main social determinants using the National Health Household Survey (ENS) from 2006. Cross sectional study based on the ENS-2006. Sample of 29,478 adults who answered questions on self-reported weight and height. We calculated the body mass index (WHO classification) for the dependent variable. Sociodemographic independent variables used were age, sex, marriage status, educational level, social class (manual, non-manual), and monthly income. A descriptive study was conducted as well as different logistic regression models. In 2006, the prevalence of overweight is higher in men (43.9%) than women (28.9%). Sex differences were not observed in the prevalence of obesity (15.0%). The multinomial logistic regression analysis shows significant associations between obesity and marriage status: married OR=1.69 (1.51-1.89), widower OR=1.77 (1.45-2.16); population without education: OR=2.77 (2.34-3.28) and income below 600 €: OR=1.50 (1.18-1.91). There was a statistically significant interaction (p<0.001) between sex and social class. Women from manual social class have 49% more chances to be overweight and 96% greater risk of obesity compared to non-manual social class women. In addition, men of manual social class have less risk of overweight (18%) and obesity (12%) than non-manual social class men. Gender and socioeconomic status are key social determinants for obesity in Spain and, consequently, this needs to be addressed when developing preventive activities. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen
2004-01-01
Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.
EVALUATION OF REBOUND TONOMETRY IN RED-EARED SLIDER TURTLES (TRACHEMYS SCRIPTA ELEGANS)
Delgado, Cherlene; Mans, Christoph; McLellan, Gillian J.; Bentley, Ellison; Sladky, Kurt K.; Miller, Paul E.
2013-01-01
Objective To evaluate feasibility and accuracy of intraocular pressure (IOP) measurement by rebound tonometry in adult red-eared slider turtles and determine the effects of manual and chemical restraint on IOP. Animal studied Seventeen adult red-eared slider turtles. Procedures IOP was measured with TonoLab® and TonoVet® tonometers in conscious, unrestrained turtles. To evaluate the effects of manual restraint, turtles were restrained by digital pressure on the rostral head or proximal neck. The effect of two chemical restraint protocols (dexmedetomidine, ketamine, midazolam [DKM] and dexmedetomidine, ketamine [DK] subcutaneously) on IOP was evaluated. Triplicate TonoLab® and TonoVet® readings were compared to direct manometry in 3 ex vivo turtle eyes. Results TonoLab® correlated better with manometry at IOPs <45 mm Hg than TonoVet® (linear regression slopes of 0.89 and 0.30 respectively). Mean (±SD) IOP in unrestrained conscious turtles was significantly lower (P<0.01) with TonoLab® (10.02 ± 0.66 mmHg) than with TonoVet® (11.32 ± 1.57 mmHg). Manual neck restraint caused a significant increase in IOP (+6.31 ± 5.59 mmHg), while manual rostral head restraint did not. Both chemical restraint protocols significantly reduced IOP (DKM: −1.0 ± 0.76 mmHg,; DK: −1.79 ± 1.17) compared to measurements in conscious unrestrained turtles. Conclusions Chemical and manual neck restraint affected IOP. Rostral head restraint had no significant effect on IOP and is, therefore, recommended as the appropriate restraint technique in red-eared-slider turtles. TonoLab® measurements estimated actual IOP more accurately, within physiologic range, than measurements obtained using the TonoVet®. PMID:25097909
Hargrave, Catriona; Mason, Nicole; Guidi, Robyn; Miller, Julie-Anne; Becker, Jillian; Moores, Matthew; Mengersen, Kerrie; Poulsen, Michael; Harden, Fiona
2016-03-01
Time-consuming manual methods have been required to register cone-beam computed tomography (CBCT) images with plans in the Pinnacle(3) treatment planning system in order to replicate delivered treatments for adaptive radiotherapy. These methods rely on fiducial marker (FM) placement during CBCT acquisition or the image mid-point to localise the image isocentre. A quality assurance study was conducted to validate an automated CBCT-plan registration method utilising the Digital Imaging and Communications in Medicine (DICOM) Structure Set (RS) and Spatial Registration (RE) files created during online image-guided radiotherapy (IGRT). CBCTs of a phantom were acquired with FMs and predetermined setup errors using various online IGRT workflows. The CBCTs, DICOM RS and RE files were imported into Pinnacle(3) plans of the phantom and the resulting automated CBCT-plan registrations were compared to existing manual methods. A clinical protocol for the automated method was subsequently developed and tested retrospectively using CBCTs and plans for six bladder patients. The automated CBCT-plan registration method was successfully applied to thirty-four phantom CBCT images acquired with an online 0 mm action level workflow. Ten CBCTs acquired with other IGRT workflows required manual workarounds. This was addressed during the development and testing of the clinical protocol using twenty-eight patient CBCTs. The automated CBCT-plan registrations were instantaneous, replicating delivered treatments in Pinnacle(3) with errors of ±0.5 mm. These errors were comparable to mid-point-dependant manual registrations but superior to FM-dependant manual registrations. The automated CBCT-plan registration method quickly and reliably replicates delivered treatments in Pinnacle(3) for adaptive radiotherapy.
DelRosso, Lourdes M; Chesson, Andrew L; Hoque, Romy
2013-07-15
The AASM Manual for the Scoring of Sleep and Associated Events (Manual) has provided standardized definitions for tonic and phasic REM sleep without atonia (RSWA). This study used Manual criteria to characterize REM sleep in patients with narcolepsy and idiopathic hypersomnia (IH). A retrospective review of PSG data from ICSD-2 defined patients with narcolepsy or IH, performed by two board certified sleep medicine physicians. Data compiled included REM sleep epochs and the presence in REM sleep of epochs scored as sustained muscle activity (tonic), and excessive transient muscle activity (phasic) as defined by Manual criteria. PSG data from 8 narcolepsy patients (mean age: 27.5 years; age range: 11-55) showed mean ± standard deviation values for: total REM sleep epochs 205 ± 46.1; RSWA/ phasic epochs 56.1 ± 25.4; and RSWA/tonic epochs 15.0 ± 10.7. PSG data from 8 IH patients (mean age: 33.1 years; age range: 20-57) showed mean ± standard deviation values of total REM sleep epochs 163.8 ± 67.9; RSWA/phasic epochs 6.2 ± 3.5; and RSWA/tonic epochs 0.2 ± 0.4. Comparison revealed intergroup differences in phasic REM sleep (p < 0.01) and tonic REM sleep (p < 0.01) were significantly increased in narcoleptics compared to IH. Our retrospective analysis showed that RSWA phasic activity and RSWA tonic activity are significantly increased in patients meeting ICSD-2 criteria for narcolepsy compared to patients meeting ICSD-2 criteria for IH. This robust difference, with further validation, could be useful as electrophysiological criteria differentiating the two disorders and understanding the physiological differences.
Willems, Joost I P; Shin, Alexandra M; Shin, Delaney M; Bishop, Allen T; Shin, Alexander Y
2016-04-01
Microsurgery can be challenging secondary to orientation of the vessels, accessibility, or depth of the wound. Robotically assisted microsurgery reduces tremors and improves visualization and may improve the quality of anastomosis compared with traditional microsurgery. The purpose of this study was to compare robotically assisted microsurgery to traditional microsurgery in technically challenging situations with respect to time of anastomosis, quality of anastomosis, and Objective Structured Assessment of Technical Skills. Two investigators with no prior surgery or microsurgery experience performed 160 anastomoses on artificial microvessels after undergoing standardized traditional and robotically assisted microsurgery courses. Five different exposure groups were created with depths of 0, 10, and 20 cm and sidewall angles of 20 and 30 degrees. A comparison of 80 manual with 80 robotically assisted microsurgery anastomoses in different exposure groups was undertaken. The modified Objective Structured Assessment of Technical Skills scoring system, duration per anastomosis, and a subjective comfort scale were evaluated. In the most difficult exposure, Objective Structured Assessment of Technical Skills scores were similar in both groups (p = 0.98), the duration was higher in the manual group (p = 0.004), and the subjective comfort rating was higher in the robotically assisted microsurgery group (p < 0.001). In the easiest (0-cm depth, flat) exposure, Objective Structured Assessment of Technical Skills scores were higher in the manual group (p = 0.018) and the duration was longer in the robotically assisted microsurgery group (p = 0.008). Manual surgery was superior to robotically assisted microsurgery in technically easy exposures. In difficult exposures (greater depth and lower sidewall angles), however, robotically assisted microsurgery had a shorter surgery time and a higher comfort rating, with Objective Structured Assessment of Technical Skills scores similar to those assessing traditional microsurgery. Therapeutic, V.
New Results on Unconditionally Secure Multi-receiver Manual Authentication
NASA Astrophysics Data System (ADS)
Wang, Shuhong; Safavi-Naini, Reihaneh
Manual authentication is a recently proposed model of communication motivated by the settings where the only trusted infrastructure is a low bandwidth authenticated channel, possibly realized by the aid of a human, that connects the sender and the receiver who are otherwise connected through an insecure channel and do not have any shared key or public key infrastructure. A good example of such scenarios is pairing of devices in Bluetooth. Manual authentication systems are studied in computational and information theoretic security model and protocols with provable security have been proposed. In this paper we extend the results in information theoretic model in two directions. Firstly, we extend a single receiver scenario to multireceiver case where the sender wants to authenticate the same message to a group of receivers. We show new attacks (compared to single receiver case) that can launched in this model and demonstrate that the single receiver lower bound 2log(1/ɛ) + O(1) on the bandwidth of manual channel stays valid in the multireceiver scenario. We further propose a protocol that achieves this bound and provides security, in the sense that we define, if up to c receivers are corrupted. The second direction is the study of non-interactive protocols in unconditionally secure model. We prove that unlike computational security framework, without interaction a secure authentication protocol requires the bandwidth of the manual channel to be at least the same as the message size, hence non-trivial protocols do not exist.
A simplified form of cardiotocography for antenatal fetal assessment.
Mahomed, K; Gupta, B K; Matikiti, L; Murape, T S
1992-12-01
Antenatal cardiotocography has become the primary method of evaluation of fetal wellbeing, and the relationship between the presence of fetal heart rate accelerations in response to fetal movement and subsequent good fetal outcome has been demonstrated. However, in areas where electronic monitors are few or not available it would be useful if such accelerations could be demonstrated using the Pinard stethoscope. A prospective study involving 200 women with a singleton pregnancy of more than 34 weeks gestation was performed at Harare Maternity Hospital, Harare, Zimbabwe, when a 6 min electronic trace using an external transducer was compared with simultaneously performed 6 min manual record using the Pinard stethoscope. The findings showed that the manual record has a sensitivity of 75% and although traces with excessive base line variability would show an acceleration on the manual record, in no case with a flat trace was an acceleration noted on the manual record. This acceptable degree of sensitivity would allow for a significant decrease in the number of women being referred for electronic tracing and would be a more appropriate use of limited resources in terms of manpower and equipment.
Validity and Reliability of Assessing Body Composition Using a Mobile Application.
Macdonald, Elizabeth Z; Vehrs, Pat R; Fellingham, Gilbert W; Eggett, Dennis; George, James D; Hager, Ronald
2017-12-01
The purpose of this study was to determine the validity and reliability of the LeanScreen (LS) mobile application that estimates percent body fat (%BF) using estimates of circumferences from photographs. The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators. The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99. The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.
Grimsley, Jasmine M S; Gadziola, Marie A; Wenstrup, Jeffrey J
2012-01-01
Mouse pups vocalize at high rates when they are cold or isolated from the nest. The proportions of each syllable type produced carry information about disease state and are being used as behavioral markers for the internal state of animals. Manual classifications of these vocalizations identified 10 syllable types based on their spectro-temporal features. However, manual classification of mouse syllables is time consuming and vulnerable to experimenter bias. This study uses an automated cluster analysis to identify acoustically distinct syllable types produced by CBA/CaJ mouse pups, and then compares the results to prior manual classification methods. The cluster analysis identified two syllable types, based on their frequency bands, that have continuous frequency-time structure, and two syllable types featuring abrupt frequency transitions. Although cluster analysis computed fewer syllable types than manual classification, the clusters represented well the probability distributions of the acoustic features within syllables. These probability distributions indicate that some of the manually classified syllable types are not statistically distinct. The characteristics of the four classified clusters were used to generate a Microsoft Excel-based mouse syllable classifier that rapidly categorizes syllables, with over a 90% match, into the syllable types determined by cluster analysis.
NASA Astrophysics Data System (ADS)
Penzias, Gregory; Janowczyk, Andrew; Singanamalli, Asha; Rusu, Mirabela; Shih, Natalie; Feldman, Michael; Stricker, Phillip D.; Delprado, Warick; Tiwari, Sarita; Böhm, Maret; Haynes, Anne-Maree; Ponsky, Lee; Viswanath, Satish; Madabhushi, Anant
2016-07-01
In applications involving large tissue specimens that have been sectioned into smaller tissue fragments, manual reconstruction of a “pseudo whole-mount” histological section (PWMHS) can facilitate (a) pathological disease annotation, and (b) image registration and correlation with radiological images. We have previously presented a program called HistoStitcher, which allows for more efficient manual reconstruction than general purpose image editing tools (such as Photoshop). However HistoStitcher is still manual and hence can be laborious and subjective, especially when doing large cohort studies. In this work we present AutoStitcher, a novel automated algorithm for reconstructing PWMHSs from digitized tissue fragments. AutoStitcher reconstructs (“stitches”) a PWMHS from a set of 4 fragments by optimizing a novel cost function that is domain-inspired to ensure (i) alignment of similar tissue regions, and (ii) contiguity of the prostate boundary. The algorithm achieves computational efficiency by performing reconstruction in a multi-resolution hierarchy. Automated PWMHS reconstruction results (via AutoStitcher) were quantitatively and qualitatively compared to manual reconstructions obtained via HistoStitcher for 113 prostate pathology sections. Distances between corresponding fiducials placed on each of the automated and manual reconstruction results were between 2.7%-3.2%, reflecting their excellent visual similarity.
Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin
2012-01-01
Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929
Cheawthamai, Kornkamon; Vongsirinavarat, Mantana; Hiengkaew, Vimonwan; Saengrueangrob, Sasithorn
2014-07-01
The present study aimed to compare the effectiveness of the treatment programs of home-based exercise with and without self-manual therapy in individuals with knee osteoarthritis (knee OA) in community. Forty-three participants with knee OA were randomly assigned in groups. All participants received the same home-based exercise program with or without self-manual therapy over 12 weeks. Outcome measures were pain intensity, range of motions, six-minute walk test distance, the knee injury and osteoarthritis outcome score (KOOS), short-form 36 (SF-36) and satisfaction. The results showed that the self-manual therapy program significantly decreased pain at 4 weeks, increased flexion and extension at 4 and 12 weeks, and improved the KOOS in pain item and SF-36 in physical function and mental health items. The home-based exercise group showed significant increase of the six-minute walk distance at 4 and 12 weeks, improvements in the KOOS in pain and symptom items and SF-36 in the physical function and role-emotional items. Overall, the results favored a combination of self-manual therapy and home-based exercise for patients with knee OA, which apparently showed superior benefits in decreasing pain and improving active knee range of motions.
Pineros, Oscar E
2002-01-01
Eye tracker systems have been developed concomitantly with small scanning beams to theoretically reduce ablation zone decentration and for accurate registration of all the laser pulses on the cornea. The purpose of the study was to compare the tracker-assisted with the manual centration method. Twenty-five patients (48 eyes) with myopia and/or astigmatism had laser in situ keratomileusis (LASIK) between August 1998 and February 1999 with the Technolas 117C laser. Twenty patients (38 eyes, 80%) were available for follow-up at 3 months after surgery. Eyes were assigned randomly to one of two ablation zone centration methods: Group 1: Tracker-assisted (20 eyes), Group 2: Manual (18 eyes). Mean distance between the ablation zone center and the pupillary center in the tracker-assisted centration group was 0.55 +/- 0.30 mm (range, 0.10 to 1.4 mm), and in the manual centration group, 0.43 +/- 0.23 mm (range, 0.10 to 1.0 mm) (P = .177). There was no statistically significant difference in postoperative contrast sensitivity, glare, and Topographical Corneal Surface Regularity Index (SRI) between the two groups. We obtained good results with both centration methods. We did not find superiority of the tracker-assisted over manual regarding ablation zone centration, vision quality, or regularity of the ablation.
Jones, Barbara E; Haroldsen, Candace; Madaras-Kelly, Karl; Goetz, Matthew B; Ying, Jian; Sauer, Brian; Jones, Makoto M; Leecaster, Molly; Greene, Tom; Fridkin, Scott K; Neuhauser, Melinda M; Samore, Matthew H
2018-07-01
Electronic health records provide the opportunity to assess system-wide quality measures. Veterans Affairs Pharmacy Benefits Management Center for Medication Safety uses medication use evaluation (MUE) through manual review of the electronic health records. To compare an electronic MUE approach versus human/manual review for extraction of antibiotic use (choice and duration) and severity metrics. Retrospective. Hospitalizations for uncomplicated pneumonia occurring during 2013 at 30 Veterans Affairs facilities. We compared summary statistics, individual hospitalization-level agreement, facility-level consistency, and patterns of variation between electronic and manual MUE for initial severity, antibiotic choice, daily clinical stability, and antibiotic duration. Among 2004 hospitalizations, electronic and manual abstraction methods showed high individual hospitalization-level agreement for initial severity measures (agreement=86%-98%, κ=0.5-0.82), antibiotic choice (agreement=89%-100%, κ=0.70-0.94), and facility-level consistency for empiric antibiotic choice (anti-MRSA r=0.97, P<0.001; antipseudomonal r=0.95, P<0.001) and therapy duration (r=0.77, P<0.001) but lower facility-level consistency for days to clinical stability (r=0.52, P=0.006) or excessive duration of therapy (r=0.55, P=0.005). Both methods identified widespread facility-level variation in antibiotic choice, but we found additional variation in manual estimation of excessive antibiotic duration and initial illness severity. Electronic and manual MUE agreed well for illness severity, antibiotic choice, and duration of therapy in pneumonia at both the individual and facility levels. Manual MUE showed additional reviewer-level variation in estimation of initial illness severity and excessive antibiotic use. Electronic MUE allows for reliable, scalable tracking of national patterns of antimicrobial use, enabling the examination of system-wide interventions to improve quality.
Performance evaluation of the new hematology analyzer Sysmex XN-series.
Seo, J Y; Lee, S-T; Kim, S-H
2015-04-01
The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the manual method. Fluorescent platelet count (PLT-F) was compared with the flow cytometric method. The low WBC mode and body fluid mode were also evaluated. For workflow analysis, 1005 samples were analyzed on both the XN and the XE-2100, and manual review rates were compared. All parameters measured by the XN correlated well with the XE-2100. PLT-F showed better correlation with the flow cytometric method (r(2) = 0.80) compared with optical platelet count (r(2) = 0.73) for platelet counts <70 × 10(9) /L. The low WBC mode reported accurate leukocyte differentials for samples with a WBC count <0.5 × 10(9) /L. Relatively good correlation was found for WBC counts between the manual method and the body fluid mode (r = 0.88). The XN made less flags than the XE-2100, while the sensitivities of both instruments were comparable. The XN provided reliable results on low cell counts, as well as reduced manual blood film reviews, while maintaining a proper level of diagnostic sensitivity. © 2014 John Wiley & Sons Ltd.
A pilot study of a family cognitive adaptation training guide for individuals with schizophrenia.
Kidd, Sean A; Kerman, Nick; Ernest, Debbie; Maples, Natalie; Arthur, Cicely; de Souza, Sara; Kath, Jennifer; Herman, Yarissa; Virdee, Gursharan; Collins, April; Velligan, Dawn
2018-06-01
There is a paucity of accessible, evidence-based tools for caregivers of individuals with schizophrenia. This study examines changes in the self-assessed and caregiver-assessed outcomes of people with schizophrenia after exposure to a cognitive adaptation training (CAT) guide that addressed pragmatic, in-home approaches to offset the cognitive impacts of the illness. This study examined the 4-month, pre-post outcomes of a CAT guide, as compared with a popular, general manual, for families of individuals with schizophrenia. A total of 17 caregiver-supported individual dyads completed all measures, having been randomized to either a CAT-guide group or a support-manual group. Measures included medication adherence, adaptive functioning, quality of life, and caregiver burden. Semistructured interviews assessed use and utility questions. Caregiver-assessed improvements in community functioning with medium-high effect sizes were observed in both study conditions. Self-report ratings by supported individuals did not change from baseline to 4 months and no change was observed in medication adherence or quality of life for either condition. Caregiver-burden ratings significantly declined with a large effect size, again with no difference as a function of manual type. These findings suggest that there is some promise in providing families with evidence-based information in manual form. Further research informed by this study's findings should include assessments of whether and how environmental cognitive supports can be of specific benefit to families affected by schizophrenia. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Manual therapy for plantar heel pain.
Pollack, Yosefa; Shashua, Anat; Kalichman, Leonid
2018-03-01
Manual therapy employed in the treatment of plantar heel pain includes joint or soft tissue mobilizations. Efficacy of these methods is still under debate. To determine whether manual therapy, consisting of deep massage, myofascial release or joint mobilization is effective in treating plantar heel pain. A critical review of all available studies with an emphasis on randomized controlled trials (RCTs) was performed. PubMed, PEDro, and Google Scholar databases were searched for keywords relating to plantar heel pain, joint, and soft tissue mobilizations. There were no search limitations or language restrictions. The reference lists of all retrieved articles were searched. The PEDro score was used to assess the quality of the reviewed papers. A total of six relevant RCTs were found: two examined the effectiveness of joint mobilization on plantar heel pain and four the effectiveness of soft tissue techniques. Five studies showed a positive short-term effect after manual therapy treatment, mostly soft tissue mobilizations, with or without stretching exercises for patients with plantar heel pain, compared to other treatments. One study observed that adding joint mobilization to the treatment of plantar heel pain was not effective. The quality of all studies was moderate to high. According to reviewed moderate and high-quality RCTs, soft tissue mobilization is an effective modality for treating plantar heel pain. Outcomes of joint mobilizations are controversial. Further studies are needed to evaluate the short and long-term effect of different soft tissue mobilization techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Hui; Xu, Lei; Fan, Zhanming; Liang, Junfu; Yan, Zixu; Sun, Zhonghua
2017-01-01
The aim of this study was to evaluate the workflow efficiency of a new automatic coronary-specific reconstruction technique (Smart Phase, GE Healthcare-SP) for selection of the best cardiac phase with least coronary motion when compared with expert manual selection (MS) of best phase in patients with high heart rate. A total of 46 patients with heart rates above 75 bpm who underwent single beat coronary computed tomography angiography (CCTA) were enrolled in this study. CCTA of all subjects were performed on a 256-detector row CT scanner (Revolution CT, GE Healthcare, Waukesha, Wisconsin, US). With the SP technique, the acquired phase range was automatically searched in 2% phase intervals during the reconstruction process to determine the optimal phase for coronary assessment, while for routine expert MS, reconstructions were performed at 5% intervals and a best phase was manually determined. The reconstruction and review times were recorded to measure the workflow efficiency for each method. Two reviewers subjectively assessed image quality for each coronary artery in the MS and SP reconstruction volumes using a 4-point grading scale. The average HR of the enrolled patients was 91.1±19.0bpm. A total of 204 vessels were assessed. The subjective image quality using SP was comparable to that of the MS, 1.45±0.85 vs 1.43±0.81 respectively (p = 0.88). The average time was 246 seconds for the manual best phase selection, and 98 seconds for the SP selection, resulting in average time saving of 148 seconds (60%) with use of the SP algorithm. The coronary specific automatic cardiac best phase selection technique (Smart Phase) improves clinical workflow in high heart rate patients and provides image quality comparable with manual cardiac best phase selection. Reconstruction of single-beat CCTA exams with SP can benefit the users with less experienced in CCTA image interpretation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkel, D; Bol, GH; Asselen, B van
Purpose: To develop an automated radiotherapy treatment planning and optimization workflow for prostate cancer in order to generate clinical treatment plans. Methods: A fully automated radiotherapy treatment planning and optimization workflow was developed based on the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). To evaluate our method, a retrospective planning study (n=100) was performed on patients treated for prostate cancer with 5 field intensity modulated radiotherapy, receiving a dose of 35×2Gy to the prostate and vesicles and a simultaneous integrated boost of 35×0.2Gy to the prostate only. A comparison was made between the dosimetric values of the automatically andmore » manually generated plans. Operator time to generate a plan and plan efficiency was measured. Results: A comparison of the dosimetric values show that automatically generated plans yield more beneficial dosimetric values. In automatic plans reductions of 43% in the V72Gy of the rectum and 13% in the V72Gy of the bladder are observed when compared to the manually generated plans. Smaller variance in dosimetric values is seen, i.e. the intra- and interplanner variability is decreased. For 97% of the automatically generated plans and 86% of the clinical plans all criteria for target coverage and organs at risk constraints are met. The amount of plan segments and monitor units is reduced by 13% and 9% respectively. Automated planning requires less than one minute of operator time compared to over an hour for manual planning. Conclusion: The automatically generated plans are highly suitable for clinical use. The plans have less variance and a large gain in time efficiency has been achieved. Currently, a pilot study is performed, comparing the preference of the clinician and clinical physicist for the automatic versus manual plan. Future work will include expanding our automated treatment planning method to other tumor sites and develop other automated radiotherapy workflows.« less
Effect of Exogenous Cues on Covert Spatial Orienting in Deaf and Normal Hearing Individuals
Prasad, Seema Gorur; Patil, Gouri Shanker; Mishra, Ramesh Kumar
2015-01-01
Deaf individuals have been known to process visual stimuli better at the periphery compared to the normal hearing population. However, very few studies have examined attention orienting in the oculomotor domain in the deaf, particularly when targets appear at variable eccentricity. In this study, we examined if the visual perceptual processing advantage reported in the deaf people also modulates spatial attentional orienting with eye movement responses. We used a spatial cueing task with cued and uncued targets that appeared at two different eccentricities and explored attentional facilitation and inhibition. We elicited both a saccadic and a manual response. The deaf showed a higher cueing effect for the ocular responses than the normal hearing participants. However, there was no group difference for the manual responses. There was also higher facilitation at the periphery for both saccadic and manual responses, irrespective of groups. These results suggest that, owing to their superior visual processing ability, the deaf may orient attention faster to targets. We discuss the results in terms of previous studies on cueing and attentional orienting in deaf. PMID:26517363
Effect of Exogenous Cues on Covert Spatial Orienting in Deaf and Normal Hearing Individuals.
Prasad, Seema Gorur; Patil, Gouri Shanker; Mishra, Ramesh Kumar
2015-01-01
Deaf individuals have been known to process visual stimuli better at the periphery compared to the normal hearing population. However, very few studies have examined attention orienting in the oculomotor domain in the deaf, particularly when targets appear at variable eccentricity. In this study, we examined if the visual perceptual processing advantage reported in the deaf people also modulates spatial attentional orienting with eye movement responses. We used a spatial cueing task with cued and uncued targets that appeared at two different eccentricities and explored attentional facilitation and inhibition. We elicited both a saccadic and a manual response. The deaf showed a higher cueing effect for the ocular responses than the normal hearing participants. However, there was no group difference for the manual responses. There was also higher facilitation at the periphery for both saccadic and manual responses, irrespective of groups. These results suggest that, owing to their superior visual processing ability, the deaf may orient attention faster to targets. We discuss the results in terms of previous studies on cueing and attentional orienting in deaf.
Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.
Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel
2009-06-01
Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.
Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L
2017-08-07
To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.
Wiltink, Jörg; Ruckes, Christian; Hoyer, Jürgen; Leichsenring, Falk; Joraschky, Peter; Leweke, Frank; Pöhlmann, Karin; Beutel, Manfred E
2017-03-14
Despite growing evidence for manualized psychodynamic treatments, there is a lack of studies on their transfer to routine practice. This is the first study to examine the effects of an additional training in manualized Short Term Psychodynamic Psychotherapy (STPP) on the outcome in routine psychotherapy for social anxiety disorder (SAD). The study is an extension to a large RCT comparing STPP to Cognitive-Behavioral Therapy of SAD. The manualized treatment was designed for a time limited approach with 25 individual sessions of STPP over 6 months. Private practitioners were randomized to training in manualized STPP (mSTPP) vs. treatment as usual without a specific training (tauSTPP). A total of 109 patients were enrolled (105 started treatment; 75 completed at least 20 treatment sessions). Assessments were conducted pre-treatment, after 8 and 15 weeks, after 25 treatment sessions, at the end of treatment, 6 and 12 months after termination of treatment. Remission as primary outcome was defined by the Liebowitz-Social-Anxiety-Scale (LSAS) score ≤30. Secondary outcomes were response (at least 31% reduction in LSAS), treatment duration and number of sessions, changes in social anxiety (LSAS, SPAI), depression (BDI), clinical global impression (CGI), and quality of life (EQ-5D). Remission rates of mSTPP (9%) resp. tauSTPP (16%) and also response rates of 33% resp. 28% were comparable between the two treatment approaches as well as treatment duration and number of sessions. Most of the within-group differences (baseline to 25 sessions) indicated moderate to large improvements in both treatments; within-group differences from baseline to 12 months follow-up (LSAS, SPAI, BDI, CGI) were large ranging from d = -0.605 to d = -2.937. Benefits of mSTPP were limited to single outcomes. Findings are discussed with regard to implementation and dissemination of empirically validated treatments in psychodynamic training and practice. SAD patients with a high comorbidity of personality disorders and a long treatment history may need longer treatments. German Clinical Trials Register (DRKS) DRKS00000570 , registered 03. March 2011.
Giljov, Andrey; Karenina, Karina; Malashichev, Yegor
2013-03-06
Acquisition of upright posture in evolution has been argued to facilitate manual laterality in primates. Owing to the high variety of postural habits marsupials can serve as a suitable model to test whether the species-typical body posture shapes forelimb preferences in non-primates or this phenomenon emerged only in the course of primate evolution. In the present study we aimed to explore manual laterality in marsupial quadrupeds and compare them with the results in the previously studied bipedal species. Forelimb preferences were assessed in captive grey short-tailed opossum (Monodelphis domestica) and sugar glider (Petaurus breviceps) in four different types of unimanual behaviour per species, which was not artificially evoked. We examined the possible effects of sex, age and task, because these factors have been reported to affect motor laterality in placental mammals. In both species the direction of forelimb preferences was strongly sex-related. Male grey short-tailed opossums showed right-forelimb preference in most of the observed unimanual behaviours, while male sugar gliders displayed only a slight, not significant rightward tendency. In contrast, females in both species exhibited consistent group-level preference of the left forelimb. We failed to reveal significant differences in manual preferences between tasks of potentially differing complexity: reaching a stable food item and catching live insects, as well as between the body support and food manipulation. No influence of subjects' age on limb preferences was found. The direction of sex-related differences in the manual preferences found in quadrupedal marsupials seems to be not typical for placental mammals. We suggest that the alternative way of interhemispheric connection in absence of corpus callosum may result in a fundamentally distinct mechanism of sex effect on limb preferences in marsupials compared to placentals. Our data confirm the idea that non-primate mammals differ from primates in sensitivity to task complexity. Comparison of marsupial species studied to date indicate that the vertical body orientation and the bipedalism favor the expression of individual- and population-level forelimb preferences in marsupials much like it does in primates. Our findings give the first evidence for the effect of species-typical posture on the manual laterality in non-primate mammals.
Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien
2016-11-01
To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.
Automation of a high risk medication regime algorithm in a home health care population.
Olson, Catherine H; Dierich, Mary; Westra, Bonnie L
2014-10-01
Create an automated algorithm for predicting elderly patients' medication-related risks for readmission and validate it by comparing results with a manual analysis of the same patient population. Outcome and Assessment Information Set (OASIS) and medication data were reused from a previous, manual study of 911 patients from 15 Medicare-certified home health care agencies. The medication data was converted into standardized drug codes using APIs managed by the National Library of Medicine (NLM), and then integrated in an automated algorithm that calculates patients' high risk medication regime scores (HRMRs). A comparison of the results between algorithm and manual process was conducted to determine how frequently the HRMR scores were derived which are predictive of readmission. HRMR scores are composed of polypharmacy (number of drugs), Potentially Inappropriate Medications (PIM) (drugs risky to the elderly), and Medication Regimen Complexity Index (MRCI) (complex dose forms, instructions or administration). The algorithm produced polypharmacy, PIM, and MRCI scores that matched with 99%, 87% and 99% of the scores, respectively, from the manual analysis. Imperfect match rates resulted from discrepancies in how drugs were classified and coded by the manual analysis vs. the automated algorithm. HRMR rules lack clarity, resulting in clinical judgments for manual coding that were difficult to replicate in the automated analysis. The high comparison rates for the three measures suggest that an automated clinical tool could use patients' medication records to predict their risks of avoidable readmissions. Copyright © 2014 Elsevier Inc. All rights reserved.
Urech, Tracy H.; Woodard, LeChauncy D.; Virani, Salim S.; Dudley, R. Adams; Lutschg, Meghan Z.; Petersen, Laura A.
2015-01-01
Background Hospital report cards and financial incentives linked to performance require clinical data that are reliable, appropriate, timely, and cost-effective to process. Pay-for-performance plans are transitioning to automated electronic health record (EHR) data as an efficient method to generate data needed for these programs. Objective To determine how well data from automated processing of structured EHR fields (AP-EHR) reflect data from manual chart review and the impact of these data on performance rewards. Research Design Cross-sectional analysis of performance measures used in a cluster randomized trial assessing the impact of financial incentives on guideline-recommended care for hypertension. Subjects A total of 2,840 patients with hypertension assigned to participating physicians at 12 Veterans Affairs hospital-based outpatient clinics. Fifty-two physicians and 33 primary care personnel received incentive payments. Measures Overall, positive and negative agreement indices and Cohen's kappa were calculated for assessments of guideline-recommended antihypertensive medication use, blood pressure (BP) control, and appropriate response to uncontrolled BP. Pearson's correlation coefficient was used to assess how similar participants’ calculated earnings were between the data sources. Results By manual chart review data, 72.3% of patients were considered to have received guideline-recommended antihypertensive medications compared to 65.0% by AP-EHR review (k=0.51). Manual review indicated 69.5% of patients had controlled BP compared to 66.8% by AP-EHR review (k=0.87). Compared to 52.2% of patients per the manual review, 39.8% received an appropriate response by AP-EHR review (k=0.28). Participants’ incentive payments calculated using the two methods were highly correlated (r≥0.98). Using the AP-EHR data to calculate earnings, participants’ payment changes ranged from a decrease of $91.00 (−30.3%) to an increase of $18.20 (+7.4%) for medication use (IQR, −14.4% to 0%) and a decrease of $100.10 (−31.4%) to an increase of $36.40 (+15.4%) for BP control or appropriate response to uncontrolled BP (IQR, −11.9% to −6.1%). Conclusions Pay-for-performance plans that use only EHR data should carefully consider the measures and the structure of the EHR before data collection and financial incentive disbursement. For this study, we feel that a 10% difference in the total amount of incentive earnings disbursed based on AP-EHR data compared to manual review is acceptable given the time and resources required to abstract data from medical records. PMID:26340661
Taylor, Stuart A; Slater, Andrew; Halligan, Steve; Honeyfield, Lesley; Roddie, Mary E; Demeshski, Jamshid; Amin, Hamdam; Burling, David
2007-01-01
To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. Institutional review board approval was obtained for the study; written consent for use of the surgical specimen was obtained. A colectomy specimen containing 27 polyps from a 16-year-old male patient with familial adenomatous polyposis was insufflated, submerged in a container with solution, and scanned at four-section multi-detector row computed tomography (CT). A histopathologist measured the maximum dimension of all polyps in the opened specimen. Digital photographs and line drawings were produced to aid CT-histologic measurement correlation. A novice (radiographic technician) and an experienced (radiologist) observer independently estimated polyp diameter with three methods: manual two-dimensional (2D) and manual three-dimensional (3D) measurement with software calipers and automated measurement with software (automatic). Data were analyzed with paired t tests and Bland-Altman limits of agreement. Seven polyps (
DiPaola, Matthew J; DiPaola, Christian P; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Bloch, David; Rechtine, Glenn R
2008-06-01
A study of spine biomechanics in a cadaver model. To quantify motion in multiple axes created by transfer methods from stretcher to operating table in the prone position in a cervical global instability model. Patients with an unstable cervical spine remain at high risk for further secondary injury until their spine is adequately surgically stabilized. Previous studies have revealed that collars have significant, but limited benefit in preventing cervical motion when manually transferring patients. The literature proposes multiple methods of patient transfer, although no one method has been universally adopted. To date, no study has effectively evaluated the relationship between spine motion and various patient transfer methods to an operating room table for prone positioning. A global instability was surgically created at C5-6 in 4 fresh cadavers with no history of spine pathology. All cadavers were tested both with and without a rigid cervical collar in the intact and unstable state. Three headrest permutations were evaluated Mayfield (SM USA Inc), Prone View (Dupaco, Oceanside, CA), and Foam Pillow (OSI, Union City, CA). A trained group of medical staff performed each of 2 transfer methods: the "manual" and the "Jackson table" transfer. The manual technique entailed performing a standard rotation of the supine patient on a stretcher to the prone position on the operating room table with in-line manual cervical stabilization. The "Jackson" technique involved sliding the supine patient to the Jackson table (OSI, Union City, CA) with manual in-line cervical stabilization, securing them to the table, then initiating the table's lock and turn mechanism and rotating them into a prone position. An electromagnetic tracking device captured angular motion between the C5 and C6 vertebral segments. Repeated measures statistical analysis was performed to evaluate the following conditions: collar use (2 levels), headrest (3 levels), and turning technique (2 levels). For all measures, there was significantly more cervical spine motion during manual prone positioning compared with using the Jackson table. The use of a collar provided a slight reduction in motion in all the planes of movement; however, this was only significantly different from the no collar condition in axial rotation. Differences in gross motion between the headrest type were observed in lateral bending (Foam Pillow
Carryover effects of highly automated convoy driving on subsequent manual driving performance.
Skottke, Eva-Maria; Debus, Günter; Wang, Lei; Huestegge, Lynn
2014-11-01
In the present study, we tested to what extent highly automated convoy driving involving small spacing ("platooning") may affect time headway (THW) and standard deviation of lateral position (SDLP) during subsequent manual driving. Although many previous studies have reported beneficial effects of automated driving, some research has also highlighted potential drawbacks, such as increased speed and reduced THW during the activation of semiautomated driving systems. Here, we rather focused on the question of whether switching from automated to manual driving may produce unwanted carryover effects on safety-relevant driving performance. We utilized a pre-post simulator design to measure THW and SDLP after highly automated driving and compared the data with those for a control group (manual driving throughout). Our data revealed that THW was reduced and SDLP increased after leaving the automation mode. A closer inspection of the data suggested that specifically the effect on THW is likely due to sensory and/or cognitive adaptation processes. Behavioral adaptation effects need to be taken into account in future implementations of automated convoy systems. Potential application areas of this research comprise automated freight traffic (truck convoys) and the design of driver assistance systems in general. Potential countermeasures against following at short distance as behavioral adaptation should be considered.
van der Slegt, Jasper; Verbogt, Nathalie Pa; Mulder, Paul Gh; Steunenberg, Stijn L; Steunenberg, Bastiaan E; van der Laan, Lijckle
2016-10-01
An automated ankle-brachial index device could lead to potential time savings and more accuracy in ankle-brachial index-determination after vascular surgery. This prospective cross-sectional study compared postprocedural ankle-brachial indices measured by a manual method with ankle-brachial indices of an automated plethysmographic method. Forty-two patients were included. No significant difference in time performing a measurement was observed (1.1 min, 95% CI: -0.2 to +2.4; P = 0.095). Mean ankle-brachial index with the automated method was 0.105 higher (95% CI: 0.017 to 0.193; P = 0.020) than with the manual method, with limits of agreement of -0.376 and +0.587. Total variance amounted to 0.0759 and the correlation between both methods was 0.60. Reliability expressed as maximum absolute difference (95% level) between duplicate ankle-brachial index-measurements under identical conditions was 0.350 (manual) and 0.152 (automated), although not significant (p = 0.053). Finally, the automated method had 34% points higher failure rate than the manual method. In conclusion based on this study, the automated ankle-brachial index-method seems not to be clinically applicable for measuring ankle-brachial index postoperatively in patients with vascular disease. © The Author(s) 2016.
Winslow, Ksenia; Ho, Andrew; Fortney, Kristen; Morgen, Eric
2017-01-01
Biomarkers of all-cause mortality are of tremendous clinical and research interest. Because of the long potential duration of prospective human lifespan studies, such biomarkers can play a key role in quantifying human aging and quickly evaluating any potential therapies. Decades of research into mortality biomarkers have resulted in numerous associations documented across hundreds of publications. Here, we present MortalityPredictors.org, a manually-curated, publicly accessible database, housing published, statistically-significant relationships between biomarkers and all-cause mortality in population-based or generally healthy samples. To gather the information for this database, we searched PubMed for appropriate research papers and then manually curated relevant data from each paper. We manually curated 1,576 biomarker associations, involving 471 distinct biomarkers. Biomarkers ranged in type from hematologic (red blood cell distribution width) to molecular (DNA methylation changes) to physical (grip strength). Via the web interface, the resulting data can be easily browsed, searched, and downloaded for further analysis. MortalityPredictors.org provides comprehensive results on published biomarkers of human all-cause mortality that can be used to compare biomarkers, facilitate meta-analysis, assist with the experimental design of aging studies, and serve as a central resource for analysis. We hope that it will facilitate future research into human mortality and aging. PMID:28858850
Choi, Jioun; Hwangbo, Gak; Park, Jungseo; Lee, Sangyong
2014-01-01
[Purpose] The purpose of this study was to examine the effects of manual therapy using joint mobilization and flexion-distraction techniques on chronic low back pain and disc heights. [Subjects] This study was conducted with 31 chronic low back pain patients who were divided into a manual therapy group (MTG; n=16) and a spinal decompression therapy group (SDTG; n=15). [Methods] The MTG was treated using joint mobilization techniques and flexion-distraction techniques, and the SDTG was treated using spinal decompression therapeutic apparatuses. Conservative physical therapy was used in both groups, and the therapy was implemented three times per week for 6 weeks. The visual analog scale (VAS) was used to measure patient’s low back pain scores, and a picture archiving and communication system was used to measure disc height by comparing and analyzing the images. [Results] In comparisons of the VAS within each of the two groups, both the MTG and the SDTG showed significant decreases. In comparisons of disc height within each of the two groups, the MTG showed statistically significant increases. [Conclusion] Manual therapy using joint mobilization techniques and flexion-distraction techniques is considered an effective intervention for addressing low back pain and disc heights in patients with chronic low back pain. PMID:25202191
Peto, Maximus V; De la Guardia, Carlos; Winslow, Ksenia; Ho, Andrew; Fortney, Kristen; Morgen, Eric
2017-08-31
Biomarkers of all-cause mortality are of tremendous clinical and research interest. Because of the long potential duration of prospective human lifespan studies, such biomarkers can play a key role in quantifying human aging and quickly evaluating any potential therapies. Decades of research into mortality biomarkers have resulted in numerous associations documented across hundreds of publications. Here, we present MortalityPredictors.org , a manually-curated, publicly accessible database, housing published, statistically-significant relationships between biomarkers and all-cause mortality in population-based or generally healthy samples. To gather the information for this database, we searched PubMed for appropriate research papers and then manually curated relevant data from each paper. We manually curated 1,576 biomarker associations, involving 471 distinct biomarkers. Biomarkers ranged in type from hematologic (red blood cell distribution width) to molecular (DNA methylation changes) to physical (grip strength). Via the web interface, the resulting data can be easily browsed, searched, and downloaded for further analysis. MortalityPredictors.org provides comprehensive results on published biomarkers of human all-cause mortality that can be used to compare biomarkers, facilitate meta-analysis, assist with the experimental design of aging studies, and serve as a central resource for analysis. We hope that it will facilitate future research into human mortality and aging.
Mengelkoch, Larry J; Highsmith, M Jason; Morris, Merry L
2014-09-01
Mobility devices for dancers with physical mobility impairments have previously been limited to traditional manual or power wheelchairs. The hands-free torso-controlled mobility chair is a unique powered mobility device which allows greater freedom and expression of movement of the trunk and upper extremities. This study compared differences in energy expenditure during a standardized dance activity using three mobility devices: the hands-free torso-controlled mobility chair, a manual sports wheelchair with hand-arm control, and an electric power chair with hand-joystick control. An experienced dancer with C7 incomplete spinal cord injury (SCI) and an experienced able-bodied dancer were recruited for testing. Three measurement trials were obtained for each chair per subject. Oxygen uptake (VO2) and heart rate (HR) were measured continuously during the dance activity. Immediately following the dance activity, subjects rated perceived exertion. Significant differences (p ≤ 0.05) and similar linear patterns in VO2 and HR responses were observed between chairs for both dancers. When the hands-free mobility chair was used, the dance activity required a moderate level of energy expenditure compared to the manual sports chair or electric power chair for both dancers. Higher ratings of perceived exertion were observed in the manual chair compared to the other chairs for the dancer with SCI, but were similar between chairs for the able-bodied dancer. These results suggest that for a dancer with high-level SCI, the hands-free torso-controlled mobility chair may offer improved freedom and expressive movement possibilities and is an energy-efficient mobility device.
Xu, Zhoubing; Gertz, Adam L.; Burke, Ryan P.; Bansal, Neil; Kang, Hakmook; Landman, Bennett A.; Abramson, Richard G.
2016-01-01
OBJECTIVES Multi-atlas fusion is a promising approach for computer-assisted segmentation of anatomical structures. The purpose of this study was to evaluate the accuracy and time efficiency of multi-atlas segmentation for estimating spleen volumes on clinically-acquired CT scans. MATERIALS AND METHODS Under IRB approval, we obtained 294 deidentified (HIPAA-compliant) abdominal CT scans on 78 subjects from a recent clinical trial. We compared five pipelines for obtaining splenic volumes: Pipeline 1–manual segmentation of all scans, Pipeline 2–automated segmentation of all scans, Pipeline 3–automated segmentation of all scans with manual segmentation for outliers on a rudimentary visual quality check, Pipelines 4 and 5–volumes derived from a unidimensional measurement of craniocaudal spleen length and three-dimensional splenic index measurements, respectively. Using Pipeline 1 results as ground truth, the accuracy of Pipelines 2–5 (Dice similarity coefficient [DSC], Pearson correlation, R-squared, and percent and absolute deviation of volume from ground truth) were compared for point estimates of splenic volume and for change in splenic volume over time. Time cost was also compared for Pipelines 1–5. RESULTS Pipeline 3 was dominant in terms of both accuracy and time cost. With a Pearson correlation coefficient of 0.99, average absolute volume deviation 23.7 cm3, and 1 minute per scan, Pipeline 3 yielded the best results. The second-best approach was Pipeline 5, with a Pearson correlation coefficient 0.98, absolute deviation 46.92 cm3, and 1 minute 30 seconds per scan. Manual segmentation (Pipeline 1) required 11 minutes per scan. CONCLUSION A computer-automated segmentation approach with manual correction of outliers generated accurate splenic volumes with reasonable time efficiency. PMID:27519156
Meguerditchian, Adrien; Vauclair, Jacques; Hopkins, William D
2013-09-01
Within the evolutionary framework about the origin of human handedness and hemispheric specialization for language, the question of expression of population-level manual biases in nonhuman primates and their potential continuities with humans remains controversial. Nevertheless, there is a growing body of evidence showing consistent population-level handedness particularly for complex manual behaviors in both monkeys and apes. In the present article, within a large comparative approach among primates, we will review our contribution to the field and the handedness literature related to two particular sophisticated manual behaviors regarding their potential and specific implications for the origins of hemispheric specialization in humans: bimanual coordinated actions and gestural communication. Whereas bimanual coordinated actions seem to elicit predominance of left-handedness in arboreal primates and of right-handedness in terrestrial primates, all handedness studies that have investigated gestural communication in several primate species have reported stronger degree of population-level right-handedness compared to noncommunicative actions. Communicative gestures and bimanual actions seem to affect differently manual asymmetries in both human and nonhuman primates and to be related to different lateralized brain substrates. We will discuss (1) how the data of hand preferences for bimanual coordinated actions highlight the role of ecological factors in the evolution of handedness and provide additional support the postural origin theory of handedness proposed by MacNeilage [MacNeilage [2007]. Present status of the postural origins theory. In W. D. Hopkins (Ed.), The evolution of hemispheric specialization in primates (pp. 59-91). London: Elsevier/Academic Press] and (2) the hypothesis that the emergence of gestural communication might have affected lateralization in our ancestor and may constitute the precursors of the hemispheric specialization for language. © 2013 Wiley Periodicals, Inc.
Lüthje, Lars; Vollmann, Dirk; Seegers, Joachim; Dorenkamp, Marc; Sohns, Christian; Hasenfuss, Gerd; Zabel, Markus
2011-11-01
Only limited data exist on the clinical utility of remote magnetic navigation (RMN) for pulmonary vein (PV) ablation. Aim of this prospective study was to evaluate the safety and efficacy of RMN for PV isolation as compared to the manual (CON) approach. A total of 161 consecutive patients undergoing circumferential PV isolation were included. Open-irrigated 3.5 mm ablation catheters under the guidance of a mapping system were used. The catheter was navigated with the Stereotaxis Niobe II system in the RMN group (n = 107) and guided manually in the CON group (n = 54). Electrical isolation of all PVs was achieved in 90% of the patients in the RMN group and in 87% in the CON group (p = 0.6). All subjects were followed every 3 months by 7d Holter-ECG. At 12 months of follow-up, 53.5% (RMN) and 55.5% (CON) of the patients were free of any left atrial tachycardia/atrial fibrillation (AF) episode (p = 0.57). Free of symptomatic AF recurrence were 66.3% (RMN) and 62.1% (CON) of the subjects (p = 0.80). Use of RMN was associated with longer procedure duration (p < 0.0001), ablation times (p < 0.0001), and RF current application duration (p < 0.05). In contrast, fluoroscopy time was lower in the RMN group (p < 0.0001). Major complications occurred in 6 of 161 procedures (3.7%), with no significant difference between groups (p = 0.75). RMN-guided PV ablation provides comparable acute and long-term success rates as compared to manual navigation. Procedural complication rates are similar. The use of RMN is associated with markedly reduced fluoroscopy time, but prolonged ablation and procedure duration.
Ciepiela, Olga; Kotuła, Iwona; Kierat, Szymon; Sieczkowska, Sandra; Podsiadłowska, Anna; Jenczelewska, Anna; Księżarczyk, Karolina; Demkow, Urszula
2016-11-01
Modern automated laboratory hematology analyzers allow the measurement of over 30 different hematological parameters useful in the diagnostic and clinical interpretation of patient symptoms. They use different methods to measure the same parameters. Thus, a comparison of complete blood count made by Mindray BC-6800, Sysmex XN-2000 and Beckman Coulter LH750 was performed. A comparison of results obtained by automated analysis of 807 anticoagulated blood samples from children and 125 manual microscopic differentiations were performed. This comparative study included white blood cell count, red blood cell count, and erythrocyte indices, as well as platelet count. The present study showed a poor level of agreement between white blood cell enumeration and differentiation of the three automated hematology analyzers under comparison. A very good agreement was found when comparing manual blood smear and automated granulocytes, monocytes, and lymphocytes differentiation. Red blood cell evaluation showed better agreement than white blood cells between the studied analyzers. To conclude, studied instruments did not ensure satisfactory interchangeability and did not facilitate a substitution of one analyzer by another. © 2016 Wiley Periodicals, Inc.
Improving patient safety via automated laboratory-based adverse event grading.
Niland, Joyce C; Stiller, Tracey; Neat, Jennifer; Londrc, Adina; Johnson, Dina; Pannoni, Susan
2012-01-01
The identification and grading of adverse events (AEs) during the conduct of clinical trials is a labor-intensive and error-prone process. This paper describes and evaluates a software tool developed by City of Hope to automate complex algorithms to assess laboratory results and identify and grade AEs. We compared AEs identified by the automated system with those previously assessed manually, to evaluate missed/misgraded AEs. We also conducted a prospective paired time assessment of automated versus manual AE assessment. We found a substantial improvement in accuracy/completeness with the automated grading tool, which identified an additional 17% of severe grade 3-4 AEs that had been missed/misgraded manually. The automated system also provided an average time saving of 5.5 min per treatment course. With 400 ongoing treatment trials at City of Hope and an average of 1800 laboratory results requiring assessment per study, the implications of these findings for patient safety are enormous.
Bauquier, Sebastien H; Lai, Alan; Jiang, Jonathan L; Sui, Yi; Cook, Mark J
2015-10-01
The aim of this prospective blinded study was to evaluate an automated algorithm for spike-and-wave discharge (SWD) detection applied to EEGs from genetic absence epilepsy rats from Strasbourg (GAERS). Five GAERS underwent four sessions of 20-min EEG recording. Each EEG was manually analyzed for SWDs longer than one second by two investigators and automatically using an algorithm developed in MATLAB®. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the manual (reference) versus the automatic (test) methods. The results showed that the algorithm had specificity, sensitivity, PPV and NPV >94%, comparable to published methods that are based on analyzing EEG changes in the frequency domain. This provides a good alternative as a method designed to mimic human manual marking in the time domain.
Semiautomated Device for Batch Extraction of Metabolites from Tissue Samples
2012-01-01
Metabolomics has become a mainstream analytical strategy for investigating metabolism. The quality of data derived from these studies is proportional to the consistency of the sample preparation. Although considerable research has been devoted to finding optimal extraction protocols, most of the established methods require extensive sample handling. Manual sample preparation can be highly effective in the hands of skilled technicians, but an automated tool for purifying metabolites from complex biological tissues would be of obvious utility to the field. Here, we introduce the semiautomated metabolite batch extraction device (SAMBED), a new tool designed to simplify metabolomics sample preparation. We discuss SAMBED’s design and show that SAMBED-based extractions are of comparable quality to extracts produced through traditional methods (13% mean coefficient of variation from SAMBED versus 16% from manual extractions). Moreover, we show that aqueous SAMBED-based methods can be completed in less than a quarter of the time required for manual extractions. PMID:22292466
Giesbrecht, Ed M; Ripat, Jacquie D; Cooper, Juliette E; Quanbury, Arthur O
2011-04-01
Occupational therapists strive to engage individuals in occupation and enhance community access through wheelchair prescription. Previous research with pushrim-activated, power-assisted wheelchairs identifies a reduction in the physical demands of manual wheelchair propulsion but limited evidence exists regarding user evaluation in context. This study explored the experience of using a power-assisted wheelchair in the community. Eight individuals who used both a power and manual device participated in focus groups after trialing a power-assist wheelchair for three weeks. Data were analyzed using a qualitative description approach. Three themes emerged from our analysis: relative advantages and disadvantages; environmental factors that affect accessibility; and evaluation of mobility device. Participants perceived the power-assist as improving performance and accessibility compared with the manual wheelchair, increasing the potential scope of occupations and environments, but not replacing their power mobility device. Sufficient time for adjustment of both user and device was important.
Foda, Abd Al-Rahman Mohammad
2013-05-01
Manual tissue microarray (TMA) construction had been introduced to avoid the high cost of automated and semiautomated techniques. The cheapest and simplest technique for constructing manual TMA was that of using mechanical pencil tips. This study was carried out to modify this method, aiming to raise its quality to reach that of expensive ones. Some modifications were introduced to Shebl's technique. Two conventional mechanical pencil tips of different diameters were used to construct the recipient blocks. A source of mild heat was used, and blocks were incubated at 38°C overnight. With our modifications, 3 high-density TMA blocks were constructed. We successfully performed immunostaining without substantial tissue loss. Our modifications increased the number of cores per block and improved the stability of the cores within the paraffin block. This new, modified technique is a good alternative for expensive machines in many laboratories.
Bove, Allyn M; Smith, Kenneth J; Bise, Christopher G; Fritz, Julie M; Childs, John; Brennan, Gerard P; Abbott, J Haxby; Fitzgerald, G Kelley
2018-01-01
Limited information exists regarding the cost-effectiveness of rehabilitation strategies for individuals with knee osteoarthritis (OA). The study objective was to compare the cost-effectiveness of 4 different combinations of exercise, manual therapy, and booster sessions for individuals with knee OA. This economic evaluation involved a cost-effectiveness analysis performed alongside a multicenter randomized controlled trial. The study took place in Pittsburgh, Pennsylvania; Salt Lake City, Utah; and San Antonio, Texas. The study participants were 300 individuals taking part in a randomized controlled trial investigating various physical therapy strategies for knee OA. Participants were randomized into 4 treatment groups: exercise only (EX), exercise plus booster sessions (EX+B), exercise plus manual therapy (EX+MT), and exercise plus manual therapy and booster sessions (EX+MT+B). For the 2-year base case scenario, a Markov model was constructed using the United States societal perspective and a 3% discount rate for costs and quality-adjusted life years (QALYs). Incremental cost-effectiveness ratios were calculated to compare differences in cost per QALY gained among the 4 treatment strategies. In the 2-year analysis, booster strategies (EX+MT+B and EX+B) dominated no-booster strategies, with both lower health care costs and greater effectiveness. EX+MT+B had the lowest total health care costs. EX+B cost ${\\$}$1061 more and gained 0.082 more QALYs than EX+MT+B, for an incremental cost-effectiveness ratio of ${\\$}$12,900/QALY gained. The small number of total knee arthroplasty surgeries received by individuals in this study made the assessment of whether any particular strategy was more successful at delaying or preventing surgery in individuals with knee OA difficult. Spacing exercise-based physical therapy sessions over 12 months using periodic booster sessions was less costly and more effective over 2 years than strategies not containing booster sessions for individuals with knee OA. © 2017 American Physical Therapy Association
Russ, Daniel E; Ho, Kwan-Yuet; Colt, Joanne S; Armenti, Karla R; Baris, Dalsu; Chow, Wong-Ho; Davis, Faith; Johnson, Alison; Purdue, Mark P; Karagas, Margaret R; Schwartz, Kendra; Schwenn, Molly; Silverman, Debra T; Johnson, Calvin A; Friesen, Melissa C
2016-06-01
Mapping job titles to standardised occupation classification (SOC) codes is an important step in identifying occupational risk factors in epidemiological studies. Because manual coding is time-consuming and has moderate reliability, we developed an algorithm called SOCcer (Standardized Occupation Coding for Computer-assisted Epidemiologic Research) to assign SOC-2010 codes based on free-text job description components. Job title and task-based classifiers were developed by comparing job descriptions to multiple sources linking job and task descriptions to SOC codes. An industry-based classifier was developed based on the SOC prevalence within an industry. These classifiers were used in a logistic model trained using 14 983 jobs with expert-assigned SOC codes to obtain empirical weights for an algorithm that scored each SOC/job description. We assigned the highest scoring SOC code to each job. SOCcer was validated in 2 occupational data sources by comparing SOC codes obtained from SOCcer to expert assigned SOC codes and lead exposure estimates obtained by linking SOC codes to a job-exposure matrix. For 11 991 case-control study jobs, SOCcer-assigned codes agreed with 44.5% and 76.3% of manually assigned codes at the 6-digit and 2-digit level, respectively. Agreement increased with the score, providing a mechanism to identify assignments needing review. Good agreement was observed between lead estimates based on SOCcer and manual SOC assignments (κ 0.6-0.8). Poorer performance was observed for inspection job descriptions, which included abbreviations and worksite-specific terminology. Although some manual coding will remain necessary, using SOCcer may improve the efficiency of incorporating occupation into large-scale epidemiological studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Weissbach, T; Haikin-Herzberger, E; Bacci-Hugger, K; Shechter-Maor, G; Fejgin, M; Biron-Shental, T
2015-09-01
Approximately 1% of term deliveries are complicated by retained products of conception. Untreated, this condition may cause bleeding, infection and intrauterine adhesions. This study assessed whether performing routine bedside uterine ultrasound immediately after manual removal of the placenta reduced the occurrence of undiagnosed, retained products of conception and its associated complications. A retrospective study was conducted using the records of patients who delivered and underwent manual removal of placenta at a single obstetrics center over a 6-year period. The outcomes of patients who were assessed using immediate bedside ultrasound were compared to a similar group who were treated based on clinical evaluation alone. All patients underwent ultrasound examination prior to discharge. Outcome variables included the rate of additional interventions (medical or surgical), abnormal pre-discharge uterine ultrasound findings, postpartum hemorrhage rate, puerperal fever and length of hospital stay. A total of 399 charts were reviewed. Immediate post-procedural ultrasound was performed in 235 patients. The remaining 164 women did not undergo immediate post-procedural ultrasound. All patients underwent an ultrasound examination prior to discharge. Among the patients who had an immediate post-procedural ultrasound, 12 (5.1%) received immediate re-intervention (2 methergine, 6 curettage and 4 manual uterine revision) vs. no intervention in the second group (p<0.001). No statistically significant difference was found between the group of patients who had immediate post-procedural ultrasound and those who did not, in the rates of postpartum hemorrhage (3.1% vs. 0.7%, p=0.13), abnormal ultrasound findings prior to discharge (14.9% vs. 14.8%, p=0.96) or additional late intervention (7.2% vs. 7.9%, p=0.79), respectively. Our findings suggest that immediate, bedside uterine ultrasound examination after manual removal of placenta might not change patient outcomes. Furthermore, it might increase unnecessary interventions. Further studies are needed to prospectively assess the benefit of routine uterine ultrasound examination after manual removal of placenta. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mazonakis, Michalis; Grinias, Elias; Pagonidis, Konstantin; Tziritas, George; Damilakis, John
2010-02-01
The purpose of this study was to develop and evaluate a semiautomatic method for left ventricular (LV) segmentation on cine MR images and subsequent estimation of cardiac parameters. The study group comprised cardiac MR examinations of 18 consecutive patients with known or suspected coronary artery disease. The new method allowed the automatic detection of the LV endocardial and epicardial boundaries on each short-axis cine MR image using a Bayesian flooding segmentation algorithm and weighted least-squares B-splines minimization. Manual editing of the automatic contours could be performed for unsatisfactory segmentation results. The end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and LV mass estimated by the new method were compared with the reference values obtained by manually tracing the LV cavity borders. The reproducibility of the new method was determined using data from two independent observers. The mean number of endocardial and epicardial outlines not requiring any manual adjustment was more than 80% and 76% of the total contour number per study, respectively. The mean segmentation time including the required manual corrections was 2.3 ± 0.7 min per patient. LV volumes estimated by the semiautomatic method were significantly lower than those by manual tracing (P < 0.05), whereas no difference was found for EF and LV mass (P > 0.05). LV indices estimated by the two methods were well correlated (r >= 0.80). The mean difference between manual and semiautomatic method for estimating EDV, ESV, EF and LV mass was 6.1 ± 7.2 ml, 3.0 ± 5.2 ml, -0.6 ± 4.3% and -6.2 ± 12.2 g, respectively. The intraobserver and interobserver variability associated with the semiautomatic determination of LV indices was 0.5-1.2% and 0.8-3.9%, respectively. The estimation of LV parameters with the new semiautomatic segmentation method is technically feasible, highly reproducible and time effective.
Anantharaman, Venkataraman; Ng, Boon Lui Benjamin; Ang, Shiang Hu; Lee, Chun Yue Francis; Leong, Siew Hon Benjamin; Ong, Marcus Eng Hock; Chua, Siang Jin Terrance; Rabind, Antony Charles; Anjali, Nagaraj Baglody; Hao, Ying
2017-01-01
INTRODUCTION Early use of mechanical cardiopulmonary resuscitation (CPR) for out-of-hospital cardiac arrest (OHCA) may improve survival outcomes. Current evidence for such devices uses outcomes from an intention-to-treat (ITT) perspective. We aimed to determine whether early use of mechanical CPR using a LUCAS 2 device results in better outcomes. METHODS A prospective, randomised, multicentre study was conducted over one year with LUCAS 2 devices in 14 ambulances and manual CPR in 32 ambulances to manage OHCA. The primary outcome was return of spontaneous circulation (ROSC). Secondary outcomes were survival at 24 hours, discharge from hospital and 30 days. RESULTS Of the 1,274 patients recruited, 1,191 were eligible for analysis. 889 had manual CPR and 302 had LUCAS CPR. From an ITT perspective, outcomes for manual and LUCAS CPR were: ROSC 29.2% and 31.1% (odds ratio [OR] 1.09, 95% confidence interval [CI] 0.82–1.45; p = 0.537); 24-hour survival 11.2% and 13.2% (OR 1.20, 95% CI 0.81–1.78; p = 0.352); survival to discharge 3.6% and 4.3% (OR 1.20, 95% CI 0.62–2.33; p = 0.579); and 30-day survival 3.0% and 4.0% (OR 1.32, 95% CI 0.66–2.64; p = 0.430), respectively. By as-treated analysis, outcomes for manual, early LUCAS and late LUCAS CPR were: ROSC 28.0%, 36.9% and 24.5%; 24-hour survival 10.6%, 15.5% and 8.2%; survival to discharge 2.9%, 5.8% and 2.0%; and 30-day survival 2.4%, 5.8% and 0.0%, respectively. Adjusted OR for survival with early LUCAS vs. manual CPR was 1.47 after adjustment for other variables (p = 0.026). CONCLUSION This study showed a survival benefit with LUCAS CPR as compared to manual CPR only, when the device was applied early on-site. PMID:28741013
Scotland, G S; McNamee, P; Fleming, A D; Goatman, K A; Philip, S; Prescott, G J; Sharp, P F; Williams, G J; Wykes, W; Leese, G P; Olson, J A
2010-06-01
To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individuals with mild or no retinopathy). Screening outcomes and grading and diagnosis costs were modelled for a cohort of 180 000 people, with prevalence of referable retinopathy at 4%. Algorithm (b), which combines image quality assessment with detection algorithms for microaneurysms (MA), blot haemorrhages and exudates, was compared with a simpler algorithm (a) (using image quality assessment and MA/dot haemorrhage (DH) detection), and the current practice of manual grading. Compared with algorithm (a), algorithm (b) would identify an additional 113 cases of referable retinopathy for an incremental cost of pound 68 per additional case. Compared with manual grading, automated grading would be expected to identify between 54 and 123 fewer referable cases, for a grading cost saving between pound 3834 and pound 1727 per case missed. Extrapolation modelling over a 20-year time horizon suggests manual grading would cost between pound 25,676 and pound 267,115 per additional quality adjusted life year gained. Algorithm (b) is more cost-effective than the algorithm based on quality assessment and MA/DH detection. With respect to the value of introducing automated detection systems into screening programmes, automated grading operates within the recommended national standards in Scotland and is likely to be considered a cost-effective alternative to manual disease/no disease grading.
Machine-Learning Algorithms to Code Public Health Spending Accounts
Leider, Jonathon P.; Resnick, Beth A.; Alfonso, Y. Natalia; Bishai, David
2017-01-01
Objectives: Government public health expenditure data sets require time- and labor-intensive manipulation to summarize results that public health policy makers can use. Our objective was to compare the performances of machine-learning algorithms with manual classification of public health expenditures to determine if machines could provide a faster, cheaper alternative to manual classification. Methods: We used machine-learning algorithms to replicate the process of manually classifying state public health expenditures, using the standardized public health spending categories from the Foundational Public Health Services model and a large data set from the US Census Bureau. We obtained a data set of 1.9 million individual expenditure items from 2000 to 2013. We collapsed these data into 147 280 summary expenditure records, and we followed a standardized method of manually classifying each expenditure record as public health, maybe public health, or not public health. We then trained 9 machine-learning algorithms to replicate the manual process. We calculated recall, precision, and coverage rates to measure the performance of individual and ensembled algorithms. Results: Compared with manual classification, the machine-learning random forests algorithm produced 84% recall and 91% precision. With algorithm ensembling, we achieved our target criterion of 90% recall by using a consensus ensemble of ≥6 algorithms while still retaining 93% coverage, leaving only 7% of the summary expenditure records unclassified. Conclusions: Machine learning can be a time- and cost-saving tool for estimating public health spending in the United States. It can be used with standardized public health spending categories based on the Foundational Public Health Services model to help parse public health expenditure information from other types of health-related spending, provide data that are more comparable across public health organizations, and evaluate the impact of evidence-based public health resource allocation. PMID:28363034
Machine-Learning Algorithms to Code Public Health Spending Accounts.
Brady, Eoghan S; Leider, Jonathon P; Resnick, Beth A; Alfonso, Y Natalia; Bishai, David
Government public health expenditure data sets require time- and labor-intensive manipulation to summarize results that public health policy makers can use. Our objective was to compare the performances of machine-learning algorithms with manual classification of public health expenditures to determine if machines could provide a faster, cheaper alternative to manual classification. We used machine-learning algorithms to replicate the process of manually classifying state public health expenditures, using the standardized public health spending categories from the Foundational Public Health Services model and a large data set from the US Census Bureau. We obtained a data set of 1.9 million individual expenditure items from 2000 to 2013. We collapsed these data into 147 280 summary expenditure records, and we followed a standardized method of manually classifying each expenditure record as public health, maybe public health, or not public health. We then trained 9 machine-learning algorithms to replicate the manual process. We calculated recall, precision, and coverage rates to measure the performance of individual and ensembled algorithms. Compared with manual classification, the machine-learning random forests algorithm produced 84% recall and 91% precision. With algorithm ensembling, we achieved our target criterion of 90% recall by using a consensus ensemble of ≥6 algorithms while still retaining 93% coverage, leaving only 7% of the summary expenditure records unclassified. Machine learning can be a time- and cost-saving tool for estimating public health spending in the United States. It can be used with standardized public health spending categories based on the Foundational Public Health Services model to help parse public health expenditure information from other types of health-related spending, provide data that are more comparable across public health organizations, and evaluate the impact of evidence-based public health resource allocation.
Lin, Steve; Turgulov, Anuar; Taher, Ahmed; Buick, Jason E; Byers, Adam; Drennan, Ian R; Hu, Samantha; J Morrison, Laurie
2016-10-01
Cardiopulmonary resuscitation (CPR) process measures research and quality assurance has traditionally been limited to the first 5 minutes of resuscitation due to significant costs in time, resources, and personnel from manual data abstraction. CPR performance may change over time during prolonged resuscitations, which represents a significant knowledge gap. Moreover, currently available commercial software output of CPR process measures are difficult to analyze. The objective was to develop and validate a software program to help automate the abstraction and transfer of CPR process measures data from electronic defibrillators for complete episodes of cardiac arrest resuscitation. We developed a software program to facilitate and help automate CPR data abstraction and transfer from electronic defibrillators for entire resuscitation episodes. Using an intermediary Extensible Markup Language export file, the automated software transfers CPR process measures data (electrocardiogram [ECG] number, CPR start time, number of ventilations, number of chest compressions, compression rate per minute, compression depth per minute, compression fraction, and end-tidal CO 2 per minute). We performed an internal validation of the software program on 50 randomly selected cardiac arrest cases with resuscitation durations between 15 and 60 minutes. CPR process measures were manually abstracted and transferred independently by two trained data abstractors and by the automated software program, followed by manual interpretation of raw ECG tracings, treatment interventions, and patient events. Error rates and the time needed for data abstraction, transfer, and interpretation were measured for both manual and automated methods, compared to an additional independent reviewer. A total of 9,826 data points were each abstracted by the two abstractors and by the software program. Manual data abstraction resulted in a total of six errors (0.06%) compared to zero errors by the software program. The mean ± SD time measured per case for manual data abstraction was 20.3 ± 2.7 minutes compared to 5.3 ± 1.4 minutes using the software program (p = 0.003). We developed and validated an automated software program that efficiently abstracts and transfers CPR process measures data from electronic defibrillators for complete cardiac arrest episodes. This software will enable future cardiac arrest studies and quality assurance programs to evaluate the impact of CPR process measures during prolonged resuscitations. © 2016 by the Society for Academic Emergency Medicine.
Xu, Xianglong; Liu, Sheng; Rao, Yunshuang; Shi, Zumin; Wang, LianLian; Sharma, Manoj; Zhao, Yong
2016-09-13
This study aimed to assess the differences regarding anemia among pregnant women with diverse characteristics and lifestyle factors. A cross-sectional study of pregnant women was conducted between June and August 2015 in 16 hospitals in five provinces of Mainland China. Self-reported doctor-diagnosed anemia was used in the study. We included 2345 pregnant women. Of the participants, 1755 (74.8%) were pregnant women of first pregnancy (PWFP) and 590 (25.2%) were second pregnancy (PWSP). The mean age of the participants was 28.1 years (SD 4.1). Overall, the prevalence of anemia was 12.7% (13.4% and 10.7% among PWFP and PWSP, respectively). The prevalence for not eating breakfast was 11.0%. Compared with PWFP, PWSP was inversely associated with the risk of anemia (odds ratio (OR) 0.66, 95% CI 0.48-0.91). Compared with those being registered in a low ranking hospital, pregnant women who were admitted to a high (OR 0.40, 95% CI 0.28-0.57) or a medium ranking hospital (OR 0.58, 95% CI 0.37-0.92) were inversely associated with the risk of anemia. Compared with women of low income (<¥4,500), those with high income were less likely to have anemia (OR 0.68, 95% CI 0.50-0.94). Compared with women with non-manual jobs, women with manual jobs (OR 1.70, 95% CI 1.17-2.45) and unemployed women (OR 1.42, 95% CI 1.04-1.93) were associated with a greater likelihood of suffering from anemia. Pregnant women not eating breakfast are of concern. Anemia is highly prevalent among pregnant women in China. Lower socio-economic status, manual jobs, PWFP, and those who attend a lower quality hospital have a greater likelihood of suffering from anemia. Tailored interventions are needed to address these issues.
Xu, Xianglong; Liu, Sheng; Rao, Yunshuang; Shi, Zumin; Wang, LianLian; Sharma, Manoj; Zhao, Yong
2016-01-01
Objective: This study aimed to assess the differences regarding anemia among pregnant women with diverse characteristics and lifestyle factors. Methods: A cross-sectional study of pregnant women was conducted between June and August 2015 in 16 hospitals in five provinces of Mainland China. Self-reported doctor-diagnosed anemia was used in the study. Results: We included 2345 pregnant women. Of the participants, 1755 (74.8%) were pregnant women of first pregnancy (PWFP) and 590 (25.2%) were second pregnancy (PWSP). The mean age of the participants was 28.1 years (SD 4.1). Overall, the prevalence of anemia was 12.7% (13.4% and 10.7% among PWFP and PWSP, respectively). The prevalence for not eating breakfast was 11.0%. Compared with PWFP, PWSP was inversely associated with the risk of anemia (odds ratio (OR) 0.66, 95% CI 0.48–0.91). Compared with those being registered in a low ranking hospital, pregnant women who were admitted to a high (OR 0.40, 95% CI 0.28–0.57) or a medium ranking hospital (OR 0.58, 95% CI 0.37–0.92) were inversely associated with the risk of anemia. Compared with women of low income (<¥4,500), those with high income were less likely to have anemia (OR 0.68, 95% CI 0.50–0.94). Compared with women with non-manual jobs, women with manual jobs (OR 1.70, 95% CI 1.17–2.45) and unemployed women (OR 1.42, 95% CI 1.04–1.93) were associated with a greater likelihood of suffering from anemia. Conclusions: Pregnant women not eating breakfast are of concern. Anemia is highly prevalent among pregnant women in China. Lower socio-economic status, manual jobs, PWFP, and those who attend a lower quality hospital have a greater likelihood of suffering from anemia. Tailored interventions are needed to address these issues. PMID:27649213
Teaching infant car seat installation via interactive visual presence: An experimental trial.
Schwebel, David C; Johnston, Anna; Rouse, Jenni
2017-02-17
A large portion of child restraint systems (car seats) are installed incorrectly, especially when first-time parents install infant car seats. Expert instruction greatly improves the accuracy of car seat installation but is labor intensive and difficult to obtain for many parents. This study was designed to evaluate the efficacy of 3 ways of communicating instructions for proper car seat installation: phone conversation; HelpLightning, a mobile application (app) that offers virtual interactive presence permitting both verbal and interactive (telestration) visual communication; and the manufacturer's user manual. A sample of 39 young adults of child-bearing age who had no previous experience installing car seats were recruited and randomly assigned to install an infant car seat using guidance from one of those 3 communication sources. Both the phone and interactive app were more effective means to facilitate accurate car seat installation compared to the user manual. There was a trend for the app to offer superior communication compared to the phone, but that difference was not significant in most assessments. The phone and app groups also installed the car seat more efficiently and perceived the communication to be more effective and their installation to be more accurate than those in the user manual group. Interactive communication may help parents install car seats more accurately than using the manufacturer's manual alone. This was an initial study with a modestly sized sample; if results are replicated in future research, there may be reason to consider centralized "call centers" that provide verbal and/or interactive visual instruction from remote locations to parents installing car seats, paralleling the model of centralized Poison Control centers in the United States.
Effects of the Diabetes Manual 1:1 structured education in primary care.
Sturt, J A; Whitlock, S; Fox, C; Hearnshaw, H; Farmer, A J; Wakelin, M; Eldridge, S; Griffiths, F; Dale, J
2008-06-01
To determine the effects of the Diabetes Manual on glycaemic control, diabetes-related distress and confidence to self-care of patients with Type 2 diabetes. A cluster randomized, controlled trial of an intervention group vs. a 6-month delayed-intervention control group with a nested qualitative study. Participants were 48 urban general practices in the West Midlands, UK, with high population deprivation levels and 245 adults with Type 2 diabetes with a mean age of 62 years recruited pre-randomization. The Diabetes Manual is 1:1 structured education designed for delivery by practice nurses. Measured outcomes were HbA(1c), cardiovascular risk factors, diabetes-related distress measured by the Problem Areas in Diabetes Scale and confidence to self-care measured by the Diabetes Management Self-Efficacy Scale. Outcomes were assessed at baseline and 26 weeks. There was no significant difference in HbA(1c) between the intervention group and the control group [difference -0.08%, 95% confidence interval (CI) -0.28, 0.11]. Diabetes-related distress scores were lower in the intervention group compared with the control group (difference -4.5, 95% CI -8.1, -1.0). Confidence to self-care Scores were 11.2 points higher (95% CI 4.4, 18.0) in the intervention group compared with the control group. The patient response rate was 18.5%. In this population, the Diabetes Manual achieved a small improvement in patient diabetes-related distress and confidence to self-care over 26 weeks, without a change in glycaemic control. Further study is needed to optimize the intervention and characterize those for whom it is more clinically and psychologically effective to support its use in primary care.
NASA Astrophysics Data System (ADS)
Vorotnikov, A. A.; Klimov, D. D.; Romash, E. V.; Bashevskaya, O. S.; Poduraev, Yu. V.; Bazykyan, E. A.; Chunihin, A. A.
2018-03-01
Industrial robots perform technological operations, such as spot and arc welding, machining and laser cutting along different trajectories within their performance characteristics. The evaluation of these characteristics is carried out according to the criteria of the standard ISO 9283. The criteria of this standard are applicable in industrial manufacturing, but not in the medical industry, as they are not developed in the framework of medical tasks. Therefore, it is necessary to evaluate according to criteria built on different principles. In this article, the question of comparative evaluation of trajectories from program movements of a robot and manual movements of a surgeon, arising during the development of robotic medical complexes using industrial robots, is considered. A comparative evaluation is required to prove the expediency of automating medical operations in maxillofacial surgery. This study focuses on the estimation of velocity accuracy of a medical instrument. To obtain the velocity of the medical instrument, coordinates of the trajectory points from the program movements of the robot KUKA LWR4+ and trajectories from the manual movements of a professional surgeon have been measured. The measurement was carried out using a coordinate measuring machine, the laser tracker Leica LTD800. The accuracy estimation was carried out by two criteria: the criterion set out in the ISO 9283 standard, and the developed alternative criterion, the description of which is presented in this article. A quantitative comparative evaluation of the trajectories of a robot and a surgeon was obtained.
Acupuncture for functional dyspepsia.
Lan, Lei; Zeng, Fang; Liu, Guan J; Ying, Li; Wu, Xi; Liu, Mailan; Liang, Fan-Rong
2014-10-13
Functional dyspepsia (FD) has been a worldwide complaint. More effective therapies are needed with fewer adverse effects than are seen with conventional medications. Acupuncture, as a traditional therapeutic method, has been widely used for functional gastrointestinal disorders in the East. Manual acupuncture and electroacupuncture have been recognized treatments for FD, but to date, no robust evidence has been found for the effectiveness and safety of these interventions in the treatment of this condition. This review was conducted to assess the efficacy and safety of manual acupuncture and electroacupuncture in the treatment of FD. Trials meeting the inclusion criteria were identified through electronic searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, the Allied and Complementary Medicine Database (AMED), Chinese Biology Medicine Disc (CBMdisc), China National Knowledge Infrastructure (CNKI), the Wanfang Database, the VIP Database, and six trial registries. Handsearching was done to screen the reference sections of potential trials and reviews. Randomized controlled trials (RCTs) were included if investigators reported efficacy and safety of manual acupuncture or electroacupuncture for patients with FD diagnosed by Rome II or Rome III criteria, compared with medications, blank control, or sham acupuncture. Data were extracted by independent review authors. Study limitations were assessed by using the tool of The Cochrane Collabration for assessing risk of bias. For dichotomous data, risk ratios (RRs) and 95% confidence intervals (95% CIs) would be applied, and for continuous data, mean differences (MDs) and 95% CIs. A fixed-effect model was applied in the meta-analysis, or a descriptive analysis was performed. The quality of evidence for the outcome measure was assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methods. Seven studies were included in the review, involving 542 participants with FD (212 males and 330 females). These studies generally had an unclear risk of bias based on inadequate descriptions of allocation concealment and a high risk of bias based on lack of blinding. None of the studies reported on outcomes of the Functional Digestive Disorder Quality of Life questionnaire (FDDQL), the Satisfaction With Dyspepsia Related Health scale (SODA), the Digestive Health Status Instrument (DHSI), or effective/inefficient rate and symptom recurrence six months from completion of acupuncture treatment.Four RCTs of acupuncture versus medications (cisapride, domperidone, and itopride) were included in the review. No statistically significant difference was noted in the reduction in FD symptom scores and the frequency of FD attack by manual acupuncture, manual-electroacupuncture, or electroacupuncture compared with medications. In three trials of acupuncture versus sham acupuncture, all descriptive or quantitative analysis results implied that acupuncture could improve FD symptom scores and scores on the Neck Disability Index (NDI), the 36-Item Short Form Health Survey (SF-36), the Self-Rating Anxiety Scale (SAS), and the Self-Rating Depression Scale (SDS) more or as significantly as sham acupuncture. With regard to adverse effects, acupuncture was superior to cisapride treatment (one study; all minor events), but no statistically significant difference was reported between acupuncture and sham acupuncture. No adverse effects data were reported in studies examining manual acupuncture versus domperidone, manual-electroacupuncture versus domperidone, or electroacupuncture versus itopride.Nevertheless, all evidence was of low or very low quality. The body of evidence identified cannot yet permit a robust conclusion regarding the efficacy and safety of acupuncture for FD. It remains unknown whether manual acupuncture or electroacupuncture is more effective or safer than other treatments for patients with FD.
Sharing control with haptics: seamless driver support from manual to automatic control.
Mulder, Mark; Abbink, David A; Boer, Erwin R
2012-10-01
Haptic shared control was investigated as a human-machine interface that can intuitively share control between drivers and an automatic controller for curve negotiation. As long as automation systems are not fully reliable, a role remains for the driver to be vigilant to the system and the environment to catch any automation errors. The conventional binary switches between supervisory and manual control has many known issues, and haptic shared control is a promising alternative. A total of 42 respondents of varying age and driving experience participated in a driving experiment in a fixed-base simulator, in which curve negotiation behavior during shared control was compared to during manual control, as well as to three haptic tunings of an automatic controller without driver intervention. Under the experimental conditions studied, the main beneficial effect of haptic shared control compared to manual control was that less control activity (16% in steering wheel reversal rate, 15% in standard deviation of steering wheel angle) was needed for realizing an improved safety performance (e.g., 11% in peak lateral error). Full automation removed the need for any human control activity and improved safety performance (e.g., 35% in peak lateral error) but put the human in a supervisory position. Haptic shared control kept the driver in the loop, with enhanced performance at reduced control activity, mitigating the known issues that plague full automation. Haptic support for vehicular control ultimately seeks to intuitively combine human intelligence and creativity with the benefits of automation systems.
Gillard, Montgomery; Wang, Timothy S; Boyd, Charles M; Dunn, Rodney L; Fader, Darrell J; Johnson, Timothy M
2002-08-01
To directly compare cosmetic improvement and postoperative sequelae resulting from dermabrasion of surgical scars with conventional motor-powered diamond fraise vs manual dermabrasion with medium-grade drywall sanding screen. Patients were randomly assigned to receive treatment with conventional diamond fraise dermabrasion to one half of the scar and manual dermabrasion with a drywall sanding screen to the other half in a prospective, comparative clinical study. Blinded observers assessed clinical variables during a 6-month follow-up period. University hospital/cancer center-based cutaneous surgery unit. Twenty-one healthy volunteers, Fitzpatrick skin type I to III, with contour irregularities resulting from granulation (7 patients) or reconstruction (14 patients) after skin cancer excision. One half of the patient's scar was treated with motor-powered diamond fraise dermabrasion and the other half was treated with manual dermabrasion with medium-grade drywall sanding screen. Correction of contour, scarline visibility, time to reepithelialization, presence or absence of milia, degree of postoperative erythema, hypertrophic scarring, patients' subjective reports of postoperative pain, and presence of pigmentary changes were observed for both methods. Standardized scoring systems were used to quantify outcome measures. According to the standardized scoring systems, no differences were found between the 2 methods at any point. In addition, no significant differences were found between the methods for any measure at any of the time points. Both dermabrasion techniques are equally effective in improving the cosmetic appearance of surgical scars.
Bonner, Brian C; Young, Linda; Smith, Patricia A; McCombes, Wendy; Clarkson, Jan E
2005-01-01
Background To investigate, within general dental practice, patients' and vocational dental practitioners' (VDP) attitudes towards the benefits and costs of a simple scale and polish and to compare the experience of using manual versus ultrasonic instruments to scale teeth. Methods 28 VDPs and 420 patients participated. Patients were randomly allocated to either group. Patients' and VDPs' attitudes towards, and experience of, the scale and polish were elicited by means of self-administered questionnaires. Results The majority of patients (99%) believed a scale and polish was beneficial. VDPs considered ultrasonic treatment to be appropriate on significantly more occasions than they did for manual scale and polish (P < 0.001). Patient discomfort: with ultrasonic scaling 69.2% felt 'a little uncomfortable' or worse compared with 60% of those undergoing manual treatment (P = 0.072). VDPs considered treatment charges were appropriate for 77% of patients. Conclusion Routine scaling and polishing is considered beneficial by both patients and vocational trainees. The majority of patients, regardless of treatment method, experience some degree of discomfort when undergoing a scale and polish. VDPs showed a preference for the ultrasonic treatment method. PMID:15975140
Kennedy, Kristen M.; Erickson, Kirk I.; Rodrigue, Karen M.; Voss, Michelle W.; Colcombe, Stan J.; Kramer, Arthur F.; Acker, James D.; Raz, Naftali
2009-01-01
Regional manual volumetry is the gold standard of in vivo neuroanatomy, but is labor-intensive, can be imperfectly reliable, and allows for measuring limited number of regions. Voxel-based morphometry (VBM) has perfect repeatability and assesses local structure across the whole brain. However, its anatomic validity is unclear, and with its increasing popularity, a systematic comparison of VBM to manual volumetry is necessary. The few existing comparison studies are limited by small samples, qualitative comparisons, and limited selection and modest reliability of manual measures. Our goal was to overcome those limitations by quantitatively comparing optimized VBM findings with highly reliable multiple regional measures in a large sample (N = 200) across a wide agespan (18–81). We report a complex pattern of similarities and differences. Peak values of VBM volume estimates (modulated density) produced stronger age differences and a different spatial distribution from manual measures. However, when we aggregated VBM-derived information across voxels contained in specific anatomically defined regions (masks), the patterns of age differences became more similar, although important discrepancies emerged. Notably, VBM revealed stronger age differences in the regions bordering CSF and white matter areas prone to leukoaraiosis, and VBM was more likely to report nonlinearities in age-volume relationships. In the white matter regions, manual measures showed stronger negative associations with age than the corresponding VBM-based masks. We conclude that VBM provides realistic estimates of age differences in the regional gray matter only when applied to anatomically defined regions, but overestimates effects when individual peaks are interpreted. It may be beneficial to use VBM as a first-pass strategy, followed by manual measurement of anatomically-defined regions. PMID:18276037
A cost analysis comparing xeroradiography to film technics for intraoral radiography.
Gratt, B M; Sickles, E A
1986-01-01
In the United States during 1978 $730 million was spent on dental radiographic services. Currently there are three alternatives for the processing of intraoral radiographs: manual wet-tanks, automatic film units, or xeroradiography. It was the intent of this study to determine which processing system is the most economical. Cost estimates were based on a usage rate of 750 patient images per month and included a calculation of the average cost per radiograph over a five-year period. Capital costs included initial processing equipment and site preparation. Operational costs included labor, supplies, utilities, darkroom rental, and breakdown costs. Clinical time trials were employed to measure examination times. Maintenance logs were employed to assess labor costs. Indirect costs of training were estimated. Results indicated that xeroradiography was the most cost effective ($0.81 per image) compared to either automatic film processing ($1.14 per image) or manual processing ($1.35 per image). Variations in projected costs indicated that if a dental practice performs primarily complete-mouth surveys, exposes less than 120 radiographs per month, and pays less than +6.50 per hour in wages, then manual (wet-tank) processing is the most economical method for producing intraoral radiographs.
Vajawat, Mayuri; Deepika, P. C.; Kumar, Vijay; Rajeshwari, P.
2015-01-01
Aim: To compare the efficacy of powered toothbrushes in improving gingival health and reducing salivary red complex counts as compared to manual toothbrushes, among autistic individuals. Materials and Methods: Forty autistics was selected. Test group received powered toothbrushes, and control group received manual toothbrushes. Plaque index and gingival index were recorded. Unstimulated saliva was collected for analysis of red complex organisms using polymerase chain reaction. Results: A statistically significant reduction in the plaque scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.002 for controls). This reduction was statistically more significant in the test group (P = 0.024). A statistically significant reduction in the gingival scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.001 for controls). This reduction was statistically more significant in the test group (P = 0.042). No statistically significant reduction in the detection rate of red complex organisms were seen at 4 weeks in both the groups. Conclusion: Powered toothbrushes result in a significant overall improvement in gingival health when constant reinforcement of oral hygiene instructions is given. PMID:26681855
Extracting BI-RADS Features from Portuguese Clinical Texts.
Nassif, Houssam; Cunha, Filipe; Moreira, Inês C; Cruz-Correia, Ricardo; Sousa, Eliana; Page, David; Burnside, Elizabeth; Dutra, Inês
2012-01-01
In this work we build the first BI-RADS parser for Portuguese free texts, modeled after existing approaches to extract BI-RADS features from English medical records. Our concept finder uses a semantic grammar based on the BIRADS lexicon and on iterative transferred expert knowledge. We compare the performance of our algorithm to manual annotation by a specialist in mammography. Our results show that our parser's performance is comparable to the manual method.
COMPUTERIZED FGD BYPRODUCT PRODUCTION AND MARKETING SYSTEM: USERS MANUAL
The users manual describes a computerized system--consisting of a number of integrated programs, models, and data bases--that has been developed to compare the costs of power plant strategies designed to meet clean air regulations. It describes the data bases, programs, and proce...
Swords, Ronan T; Anguita, Javier; Higgins, Russell A; Yunes, Andrea C; Naski, Michael; Padmanabhan, Swaminathan; Kelly, Kevin R; Mahalingam, Devalingam; Philbeck, Thomas; Miller, Larry; Puga, Tatiana A; Giles, Francis J; Kinney, Marsha C; Brenner, Andrew J
2011-09-01
Bone marrow aspiration and biopsy is an invasive procedure associated with morbidity and mortality risk. We compared a powered bone marrow aspiration and biopsy device to the traditional method by relatively assessing pain scores, procedure times, biopsy capture rates, quality of material retrieved, and safety and operator satisfaction. Two large academic medical centres participated in this trial. Patients were randomised to have procedures carried out using the powered system or the manual technique. A visual analogue scale pain score was recorded immediately following skin puncture and once again at the end of the procedure for each patient. Procedure time was measured from skin puncture to core specimen acquisition. Pathologic assessment of 30 randomised samples was carried out. Operator satisfaction with devices was measured on a scale of 0-10, with 10 as the highest rating. Five operators from two sites enrolled 50 patients (powered, n=25; manual, n=25). Groups were evenly matched, with no significant differences in the means for age, weight and height. The powered system was superior to the manual system with respect to patient perceived pain from needle insertion (2.6±2.0 vs 4.1±2.5, p=0.022) and procedural time (100.0±72.8 s vs 224.1±79.0 s, p<0.001). Overall pain scores at the end of both procedures were comparable (3.2±2.2 vs 3.8±3.0, p=0.438). No complications were observed in either arm of the study. Blinded pathologic analysis of the specimens retrieved revealed that cores obtained using the powered system were longer and wider than those obtained using the manual technique (25.4±12.3 mm² vs 11.9±5.6 mm², p=0.001). For marrow aspiration, no difference was seen between groups for clot/particle spicules or smear spicules. Operator assessment favoured the use of the powered device. Results of this trial suggest that the use of a powered bone marrow biopsy device significantly reduces needle insertion pain and procedural time when compared to a manual technique. The superior size and overall quality of core specimens retrieved by the powered device provides more material for pathologic evaluation, thereby increasing diagnostic yield and reducing the need for repeat procedures.
Automated face detection for occurrence and occupancy estimation in chimpanzees.
Crunchant, Anne-Sophie; Egerer, Monika; Loos, Alexander; Burghardt, Tilo; Zuberbühler, Klaus; Corogenes, Katherine; Leinert, Vera; Kulik, Lars; Kühl, Hjalmar S
2017-03-01
Surveying endangered species is necessary to evaluate conservation effectiveness. Camera trapping and biometric computer vision are recent technological advances. They have impacted on the methods applicable to field surveys and these methods have gained significant momentum over the last decade. Yet, most researchers inspect footage manually and few studies have used automated semantic processing of video trap data from the field. The particular aim of this study is to evaluate methods that incorporate automated face detection technology as an aid to estimate site use of two chimpanzee communities based on camera trapping. As a comparative baseline we employ traditional manual inspection of footage. Our analysis focuses specifically on the basic parameter of occurrence where we assess the performance and practical value of chimpanzee face detection software. We found that the semi-automated data processing required only 2-4% of the time compared to the purely manual analysis. This is a non-negligible increase in efficiency that is critical when assessing the feasibility of camera trap occupancy surveys. Our evaluations suggest that our methodology estimates the proportion of sites used relatively reliably. Chimpanzees are mostly detected when they are present and when videos are filmed in high-resolution: the highest recall rate was 77%, for a false alarm rate of 2.8% for videos containing only chimpanzee frontal face views. Certainly, our study is only a first step for transferring face detection software from the lab into field application. Our results are promising and indicate that the current limitation of detecting chimpanzees in camera trap footage due to lack of suitable face views can be easily overcome on the level of field data collection, that is, by the combined placement of multiple high-resolution cameras facing reverse directions. This will enable to routinely conduct chimpanzee occupancy surveys based on camera trapping and semi-automated processing of footage. Using semi-automated ape face detection technology for processing camera trap footage requires only 2-4% of the time compared to manual analysis and allows to estimate site use by chimpanzees relatively reliably. © 2017 Wiley Periodicals, Inc.