An experimental system for the study of active vibration control - Development and modeling
NASA Astrophysics Data System (ADS)
Batta, George R.; Chen, Anning
A modular rotational vibration system designed to facilitate the study of active control of vibrating systems is discussed. The model error associated with four common types of identification problems has been studied. The general multiplicative uncertainty shape for a vibration system is small in low frequencies, large at high frequencies. The frequency-domain error function has sharp peaks near the frequency of each mode. The inability to identify a high-frequency mode causes an increase of uncertainties at all frequencies. Missing a low-frequency mode causes the uncertainties to be much larger at all frequencies than missing a high-frequency mode. Hysteresis causes a small increase of uncertainty at low frequencies, but its overall effect is relatively small.
High frequency testing of rubber mounts.
Vahdati, Nader; Saunders, L Ken Lauderbaugh
2002-04-01
Rubber and fluid-filled rubber engine mounts are commonly used in automotive and aerospace applications to provide reduced cabin noise and vibration, and/or motion accommodations. In certain applications, the rubber mount may operate at frequencies as high as 5000 Hz. Therefore, dynamic stiffness of the mount needs to be known in this frequency range. Commercial high frequency test machines are practically nonexistent, and the best high frequency test machine on the market is only capable of frequencies as high as 1000 Hz. In this paper, a high frequency test machine is described that allows test engineers to study the high frequency performance of rubber mounts at frequencies up to 5000 Hz.
Donai, Jeremy J; Halbritter, Rachel M
The purpose of this study was to investigate the ability of normal-hearing listeners to use high-frequency energy for gender identification from naturally produced speech signals. Two experiments were conducted using a repeated-measures design. Experiment 1 investigated the effects of increasing high-pass filter cutoff (i.e., increasing the low-frequency spectral limit) on gender identification from naturally produced vowel segments. Experiment 2 studied the effects of increasing high-pass filter cutoff on gender identification from naturally produced sentences. Confidence ratings for the gender identification task were also obtained for both experiments. Listeners in experiment 1 were capable of extracting talker gender information at levels significantly above chance from vowel segments high-pass filtered up to 8.5 kHz. Listeners in experiment 2 also performed above chance on the gender identification task from sentences high-pass filtered up to 12 kHz. Cumulatively, the results of both experiments provide evidence that normal-hearing listeners can utilize information from the very high-frequency region (above 4 to 5 kHz) of the speech signal for talker gender identification. These findings are at variance with current assumptions regarding the perceptual information regarding talker gender within this frequency region. The current results also corroborate and extend previous studies of the use of high-frequency speech energy for perceptual tasks. These findings have potential implications for the study of information contained within the high-frequency region of the speech spectrum and the role this region may play in navigating the auditory scene, particularly when the low-frequency portion of the spectrum is masked by environmental noise sources or for listeners with substantial hearing loss in the low-frequency region and better hearing sensitivity in the high-frequency region (i.e., reverse slope hearing loss).
Badham, Stephen P; Whitney, Cora; Sanghera, Sumeet; Maylor, Elizabeth A
2017-07-01
Many studies show that age deficits in memory are smaller for information supported by pre-experimental experience. Many studies also find dissociations in memory tasks between words that occur with high and low frequencies in language, but the literature is mixed regarding the extent of word frequency effects in normal ageing. We examined whether age deficits in episodic memory could be influenced by manipulations of word frequency. In Experiment 1, young and older adults studied short and long lists of high- and low-frequency words for free recall. The list length effect (the drop in proportion recalled for longer lists) was larger in young compared to older adults and for high- compared to low-frequency words. In Experiment 2, young and older adults completed item and associative recognition memory tests with high- and low-frequency words. Age deficits were greater for associative memory than for item memory, demonstrating an age-related associative deficit. High-frequency words led to better associative memory performance whilst low-frequency words resulted in better item memory performance. In neither experiment was there any evidence for age deficits to be smaller for high- relative to low-frequency words, suggesting that word frequency effects on memory operate independently from effects due to cognitive ageing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Feng; Zhang, Xin; Xie, Jun
2015-03-10
This study presents a new steady-state visual evoked potential (SSVEP) paradigm for brain computer interface (BCI) systems. The goal of this study is to increase the number of targets using fewer stimulation high frequencies, with diminishing subject’s fatigue and reducing the risk of photosensitive epileptic seizures. The new paradigm is High-Frequency Combination Coding-Based High-Frequency Steady-State Visual Evoked Potential (HFCC-SSVEP).Firstly, we studied SSVEP high frequency(beyond 25 Hz)response of SSVEP, whose paradigm is presented on the LED. The SNR (Signal to Noise Ratio) of high frequency(beyond 40 Hz) response is very low, which is been unable to be distinguished through the traditional analysis method;more » Secondly we investigated the HFCC-SSVEP response (beyond 25 Hz) for 3 frequencies (25Hz, 33.33Hz, and 40Hz), HFCC-SSVEP produces n{sup n} with n high stimulation frequencies through Frequence Combination Code. Further, Animproved Hilbert-huang transform (IHHT)-based variable frequency EEG feature extraction method and a local spectrum extreme target identification algorithmare adopted to extract time-frequency feature of the proposed HFCC-SSVEP response.Linear predictions and fixed sifting (iterating) 10 time is used to overcome the shortage of end effect and stopping criterion,generalized zero-crossing (GZC) is used to compute the instantaneous frequency of the proposed SSVEP respondent signals, the improved HHT-based feature extraction method for the proposed SSVEP paradigm in this study increases recognition efficiency, so as to improve ITR and to increase the stability of the BCI system. what is more, SSVEPs evoked by high-frequency stimuli (beyond 25Hz) minimally diminish subject’s fatigue and prevent safety hazards linked to photo-induced epileptic seizures, So as to ensure the system efficiency and undamaging.This study tests three subjects in order to verify the feasibility of the proposed method.« less
Kuribayashi, Ryuma; Nittono, Hiroshi
2017-01-01
High-resolution audio has a higher sampling frequency and a greater bit depth than conventional low-resolution audio such as compact disks. The higher sampling frequency enables inaudible sound components (above 20 kHz) that are cut off in low-resolution audio to be reproduced. Previous studies of high-resolution audio have mainly focused on the effect of such high-frequency components. It is known that alpha-band power in a human electroencephalogram (EEG) is larger when the inaudible high-frequency components are present than when they are absent. Traditionally, alpha-band EEG activity has been associated with arousal level. However, no previous studies have explored whether sound sources with high-frequency components affect the arousal level of listeners. The present study examined this possibility by having 22 participants listen to two types of a 400-s musical excerpt of French Suite No. 5 by J. S. Bach (on cembalo, 24-bit quantization, 192 kHz A/D sampling), with or without inaudible high-frequency components, while performing a visual vigilance task. High-alpha (10.5-13 Hz) and low-beta (13-20 Hz) EEG powers were larger for the excerpt with high-frequency components than for the excerpt without them. Reaction times and error rates did not change during the task and were not different between the excerpts. The amplitude of the P3 component elicited by target stimuli in the vigilance task increased in the second half of the listening period for the excerpt with high-frequency components, whereas no such P3 amplitude change was observed for the other excerpt without them. The participants did not distinguish between these excerpts in terms of sound quality. Only a subjective rating of inactive pleasantness after listening was higher for the excerpt with high-frequency components than for the other excerpt. The present study shows that high-resolution audio that retains high-frequency components has an advantage over similar and indistinguishable digital sound sources in which such components are artificially cut off, suggesting that high-resolution audio with inaudible high-frequency components induces a relaxed attentional state without conscious awareness.
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G; Walser, Sandra M; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E W
2017-01-01
Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Data from 278 participants (aged 18-23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
...-frequency, and high-frequency. Bryde's whale, humpback whale, and minke whale are considered low-frequency... to 160 kHz. Dwarf sperm whale and pygmy sperm whale are considered high-frequency cetaceans and their... field versus laboratory conditions. While multiple controlled studies of high-frequency cetaceans to...
NASA Astrophysics Data System (ADS)
Bernstein, Leslie R.; Trahiotis, Constantine
2005-09-01
Our purpose in this study was to determine whether across-frequency binaural interference would occur if ITD-based extents of laterality were measured using high-frequency transposed stimuli as targets. The results of an earlier study [L. R. Bernstein and C. Trahiotis, J. Acoust. Soc. Am. 116, 3062-3069 (2004)], which focused on threshold-ITDs, rather than extents of laterality, suggested that high-frequency transposed stimuli might be ``immune'' to binaural interference effects resulting from the addition of a spectrally remote, low-frequency interferer. In contrast to the earlier findings, the data from this study indicate that high-frequency transposed targets are susceptible to binaural interference. Nevertheless, high-frequency transposed targets, even when presented along with an interferer, yielded greater extents of ITD-based laterality than did high-frequency Gaussian noise targets presented in isolation. That is, the ``enhanced potency'' of ITDs conveyed by transposed stimuli persisted, even in the presence of a low-frequency interferer. Predictions made using an extension of the model of Heller and Trahiotis [L. M. Heller and C. Trahiotis, J. Acoust. Soc. Am. 99, 3632-3637 (1996)] accounted well for across-frequency binaural interference obtained with conventional Gaussian noise targets but, in all but one case, overpredicted the amounts of interference found with the transposed targets.
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G.; Walser, Sandra M.; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E.W.
2017-01-01
Background: Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. Materials and Methods: A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Results: Data from 278 participants (aged 18–23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. Conclusion: This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort. PMID:29319010
Excess noise in Pb(1-x)Sn(x)Se semiconductor lasers
NASA Technical Reports Server (NTRS)
Harward, C. N.; Sidney, B. D.
1980-01-01
The noise characteristics of the TDL were studied for frequencies less than 20 kHz. For heterodyne applications, the high frequency ( 1 MHz) characteristics are also important. Therefore, the high frequency noise characteristics of the TDL were studied as a part of a full TDL characterization program which has been implemented for the improvement of the TDL as a local oscillator in the LHS system. It was observed that all the devices showed similar high frequency noise characteristics even though they were all constructed using different techniques. These common high frequency noise characteristics are reported.
Dynamic properties of ionospheric plasma turbulence driven by high-power high-frequency radiowaves
NASA Astrophysics Data System (ADS)
Grach, S. M.; Sergeev, E. N.; Mishin, E. V.; Shindin, A. V.
2016-11-01
A review is given of the current state-of-the-art of experimental studies and the theoretical understanding of nonlinear phenomena that occur in the ionospheric F-layer irradiated by high-power high-frequency ground-based transmitters. The main focus is on the dynamic features of high-frequency turbulence (plasma waves) and low-frequency turbulence (density irregularities of various scales) that have been studied in experiments at the Sura and HAARP heating facilities operated in temporal and frequency regimes specially designed with consideration of the characteristic properties of nonlinear processes in the perturbed ionosphere using modern radio receivers and optical instruments. Experimental results are compared with theoretical turbulence models for a magnetized collisional plasma in a high-frequency electromagnetic field, allowing the identification of the processes responsible for the observed features of artificial ionospheric turbulence.
Modulation of high frequency noise by engine tones of small boats.
Pollara, Alexander; Sutin, Alexander; Salloum, Hady
2017-07-01
The effect of modulation of high frequency ship noise by propeller rotation frequencies is well known. This modulation is observed with the Detection of Envelope Modulation on Noise (DEMON) algorithm. Analysis of the DEMON spectrum allows the revolutions per minute and number of blades of the propeller to be determined. This work shows that the high frequency noise of a small boat can also be modulated by engine frequencies. Prior studies have not reported high frequency noise amplitude modulated at engine frequencies. This modulation is likely produced by bubbles from the engine exhaust system.
High Frequency Radar Astronomy With HAARP
2003-01-01
High Frequency Radar Astronomy With HAARP Paul Rodriguez Naval Research Laboratory Information Technology Division Washington, DC 20375, USA Edward...a period of several years, the High frequency Active Auroral Research Program ( HAARP ) transmitting array near Gakona, Alaska, has increased in total...high frequency (HF) radar facility used for research purposes. The basic science objective of HAARP is to study nonlinear effects associated with
Pulsed-High Field/High-Frequency EPR Spectroscopy
NASA Astrophysics Data System (ADS)
Fuhs, Michael; Moebius, Klaus
Pulsed high-field/high-frequency electron paramagnetic resonance (EPR) spectroscopy is used to disentangle many kinds of different effects often obscured in continuous wave (cw) EPR spectra at lower magnetic fields/microwave frequencies. While the high magnetic field increases the resolution of G tensors and of nuclear Larmor frequencies, the high frequencies allow for higher time resolution for molecular dynamics as well as for transient paramagnetic intermediates studied with time-resolved EPR. Pulsed EPR methods are used for example for relaxation-time studies, and pulsed Electron Nuclear DOuble Resonance (ENDOR) is used to resolve unresolved hyperfine structure hidden in inhomogeneous linewidths. In the present article we introduce the basic concepts and selected applications to structure and mobility studies on electron transfer systems, reaction centers of photosynthesis as well as biomimetic models. The article concludes with an introduction to stochastic EPR which makes use of an other concept for investigating resonance systems in order to increase the excitation bandwidth of pulsed EPR. The limited excitation bandwidth of pulses at high frequency is one of the main limitations which, so far, made Fourier transform methods hardly feasible.
Numerical study on the instabilities in H2-air rotating detonation engines
NASA Astrophysics Data System (ADS)
Liu, Yan; Zhou, Weijiang; Yang, Yunjun; Liu, Zhou; Wang, Jianping
2018-04-01
Numerical simulations of rotating detonation engines (RDEs) are performed using two-dimensional Euler equations and a detailed chemistry model of H2-air. Two propagation modes, the one-wave mode and the two-wave mode, are observed in the RDEs. The instabilities of the RDEs are studied and analyzed specifically. A low frequency instability and a high frequency instability are found from the pressure-time trace measured at a fixed location and the average density-time trace of the RDEs. For the low frequency instability, the pressure peak of the pressure-time trace oscillates with a low frequency while the average density is stable. The deviation between the measurement location and the location of the detonation wave results in the low frequency instability. For the high frequency instability, the average density of the RDEs oscillates regularly with a single frequency while the pressure oscillates irregularly with several frequencies. The oscillation of the detonation wave height results in the high frequency instability. Furthermore, the low frequency instability and the high frequency instability both occur in the one-wave and two-wave mode RDEs.
NASA Astrophysics Data System (ADS)
Umesh, P. A.; Bhaskaran, Prasad K.; Sandhya, K. G.; Nair, T. M. Balakrishnan
2017-12-01
Over the years, continued uncertainty amid - 4 and - 5 frequency exponent representation observed in the slope of the high-frequency tail of a wind-wave frequency spectrum is a major concern. To comprehend the nature of the high-frequency tail an effort has been made to assess the slope of the high-frequency tail with measured data recorded for 3 years off Gopalpur. The study demonstrates that the high-frequency slope of the spectra varied seasonally in the range of n = - 2.13 to - 3.48. The swell and wind sea parameters calculated by separation frequency method, shows that 64.6% of waves were dominant by swell and the rest 34.9% by sea annually. Single, double and multi-peaked spectra occur 12.23, 71.80 and 15.37% annually. To simulate wave spectra, the nested WAM-SWAN model is forced with ERA-Interim winds and 1D wave spectra comparisons, when performed, proved to be encouraging. From the comparisons of measured and theoretical spectra it is concluded that JONSWAP model could not describe the high-frequency tail of measured spectrum, as indicated by the very high Scatter Index ranging from 0.24 to 1.44. Whether there exists a correct slope for the high-frequency tail is still a question. Moreover, the philosophy of a unique slope at any coastal location remains uncertain for the wave modelling community.
Noise measurements during high-frequency oscillatory and conventional mechanical ventilation.
Berens, R J; Weigle, C G
1995-10-01
To evaluate the noise levels with high-frequency oscillatory ventilation and conventional mechanical ventilation. An observational, prospective study. Pediatric intensive care unit. The caretakers and environment of the pediatric intensive care unit. High-frequency oscillatory and conventional mechanical ventilation. Caretakers evaluated noise using a visual analog scale. Noise was measured with a decibel meter and an octave band frequency filter. There was twice as much noise perceived by the caretakers and as measured on the decibel A scale. All measures showed significantly greater noise, especially at low frequencies, with high-frequency oscillatory ventilation. High-frequency oscillatory ventilation exposes the patient to twice as much noise as does the use of conventional mechanical ventilation.
Research for the jamming mechanism of high-frequency laser to the laser seeker
NASA Astrophysics Data System (ADS)
Zheng, Xingyuan; Zhang, Haiyang; Wang, Yunping; Feng, Shuang; Zhao, Changming
2013-08-01
High-frequency laser will be able to enter the enemy laser signal processing systems without encoded identification and a copy. That makes it one of the research directions of new interference sources. In order to study the interference mechanism of high-frequency laser to laser guided weapons. According to the principle of high-frequency laser interference, a series of related theoretical models such as a semi-active laser seeker coded identification model, a time door model, multi-signal processing model and a interference signal modulation processing model are established. Then seeker interfere with effective 3σ criterion is proposed. Based on this, the study of the effect of multi-source interference and signal characteristics of the effect of high repetition frequency laser interference are key research. According to the simulation system testing, the results show that the multi-source interference and interference signal frequency modulation can effectively enhance the interference effect. While the interference effect of the interference signal amplitude modulation is not obvious. The research results will provide the evaluation of high-frequency laser interference effect and provide theoretical references for high-frequency laser interference system application.
Lee, Jong-Ho; Kim, Kyu-Hyeong; Hong, Jin-Woo; Lee, Won-Chul; Koo, Sungtae
2011-06-01
This study aimed to compare the effects of high frequency electroacupuncture (EA) and low-frequency EA on the autonomic nervous system by using a heart rate variability measuring device in normal individuals. Fourteen participants were recruited and each participated in the high-frequency and low-frequency sessions (crossover design). The order of sessions was randomized and the interval between the two sessions was over 2 weeks. Participants received needle insertion with 120-Hz stimulation during the high-frequency session (high-frequency EA group), and with 2-Hz stimulation during the low-frequency session (low-frequency EA group). Acupuncture needles were directly inserted perpendicularly to LI 4 and LI 11 acupoints followed by delivery of electric pulses to these points for 15 minutes. Heart rate variability was measured 5 minutes before and after EA stimulation by a heart rate variability measuring system. We found a significant increase in the standard deviation of the normal-to-normal interval in the high-frequency EA group, with no change in the low-frequency EA group. Both the high-frequency and low-frequency EA groups showed no significant differences in other parameters including high-frequency power, low-frequency power, and the ratio of low-frequency power to high-frequency power. Based on these findings, we concluded that high-frequency EA stimulation is more effective than low-frequency EA stimulation in increasing autonomic nervous activity and there is no difference between the two EA frequencies in enhancing sympathovagal balance. Copyright © 2011 Korean Pharmacopuncture Institute. Published by .. All rights reserved.
Recognition memory and awareness: A high-frequency advantage in the accuracy of knowing.
Gregg, Vernon H; Gardiner, John M; Karayianni, Irene; Konstantinou, Ira
2006-04-01
The well-established advantage of low-frequency words over high-frequency words in recognition memory has been found to occur in remembering and not knowing. Two experiments employed remember and know judgements, and divided attention to investigate the possibility of an effect of word frequency on know responses given appropriate study conditions. With undivided attention at study, the usual low-frequency advantage in the accuracy of remember responses, but no effect on know responses, was obtained. Under a demanding divided attention task at encoding, a high-frequency advantage in the accuracy of know responses was obtained. The results are discussed in relation to theories of knowing, particularly those incorporating perceptual and conceptual fluency.
2011-01-01
Background Genetic risk models could potentially be useful in identifying high-risk groups for the prevention of complex diseases. We investigated the performance of this risk stratification strategy by examining epidemiological parameters that impact the predictive ability of risk models. Methods We assessed sensitivity, specificity, and positive and negative predictive value for all possible risk thresholds that can define high-risk groups and investigated how these measures depend on the frequency of disease in the population, the frequency of the high-risk group, and the discriminative accuracy of the risk model, as assessed by the area under the receiver-operating characteristic curve (AUC). In a simulation study, we modeled genetic risk scores of 50 genes with equal odds ratios and genotype frequencies, and varied the odds ratios and the disease frequency across scenarios. We also performed a simulation of age-related macular degeneration risk prediction based on published odds ratios and frequencies for six genetic risk variants. Results We show that when the frequency of the high-risk group was lower than the disease frequency, positive predictive value increased with the AUC but sensitivity remained low. When the frequency of the high-risk group was higher than the disease frequency, sensitivity was high but positive predictive value remained low. When both frequencies were equal, both positive predictive value and sensitivity increased with increasing AUC, but higher AUC was needed to maximize both measures. Conclusions The performance of risk stratification is strongly determined by the frequency of the high-risk group relative to the frequency of disease in the population. The identification of high-risk groups with appreciable combinations of sensitivity and positive predictive value requires higher AUC. PMID:21797996
Development of a high-frequency and large-stroke fatigue testing system for rubber
NASA Astrophysics Data System (ADS)
Chen, Gang; Wu, Hao; Gao, Jianwen; Lin, Qiang
2017-04-01
The limited capabilities of current fatigue testing machines have resulted in studies on the fatigue behavior of rubber under large-displacement amplitude and high frequency being very sparse. In this study, a fatigue testing system that can carry out large-displacement amplitude and high-frequency fatigue tests on rubber was developed using a moving magnet voice coil motor (MMVCM) actuator, with finite element analysis applied to analyze the thrust of the MMVCM actuator. The results of a series of cyclic tension tests conducted on vulcanized natural rubber specimens using the developed fatigue testing system verify that it has high precision, low noise, large-stroke, and high-frequency characteristics. Further, the load frame with the developed MMVCM actuator is feasible for material testing, especially for large-stroke and high-frequency fatigue tests.
Lasso de la Vega, Mar; Villarreal, Ithzel María; López Moya, Julio; García-Berrocal, José Ramón
2017-02-01
Sensorineural hearing loss must be considered within the clinical picture of systemic lupus erythematosus. The results confirm the usefulness of extended high-frequency audiometry in the audiologic testing of these patients, enabling the possibility of modifying or applying a preventive treatment for a possible hearing loss. Hearing involvement is usually under-diagnosed with routine auditory examination. This study proposes the use of extended high-frequency audiometry to achieve a correct detection of a possible asymptomatic hypoacusis in early stages of the disease. The aim of this study is to analyze the hearing levels in extended high-frequencies in these patients and to correlate the hearing loss with the severity of the disease and the immunological parameters. A descriptive cross-sectional study was performed. Fifty-five patients with systemic lupus erythematosus were included in the study. The control group consisted of 71 patients paired by age and sex with the study population. Both a pure tone audiometry and an extended high-frequency audiometry (8-18 KHz) were performed. In total, 70% were diagnosed with sensorineural hearing loss with extended high-frequency audiometry, overcoming the results obtained with pure tone audiometry (30.9%). Statistically significant correlations were found within the patients regarding sensorineural hearing loss related with age, disease activity and cryoglobulinemia.
Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva
2016-07-01
The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.
Study of Complex Plasmas with Magnetic Dipoles
2017-10-10
variety of collective behavior manifested in a plasma, especially oscillations or waves characterized by high frequency accompanied by the motion of...behavior manifested in a plasma, especially oscillations or waves characterized by high frequency accompanied by the motion of electrons and/or ions...particles characterized by extremely low frequency modes and the collection of plasma particles characterized by high frequency modes. The interaction of
Juhasz, Barbara J; Yap, Melvin J; Raoul, Akila; Kaye, Micaela
2018-04-23
Word frequency is an important predictor of lexical-decision task performance. The current study further examined the role of this variable by exploring the influence of frequency trajectory. Frequency trajectory is measured by how often a word occurs in childhood relative to adulthood. Past research on the role of this variable in word recognition has produced equivocal results. In the current study, words were selected based on their frequencies in Grade 1 (child frequency) and Grade 13 (college frequency). In Experiment 1, four frequency trajectory conditions were factorially examined in a lexical-decision task with English words: high-to-high (world), high-to-low (uncle), low-to-high (brain) and low-to-low (opera). an interaction between Grade 1 and college frequency demonstrated that words in the low-to-high condition were processed significantly faster and more accurately than words in the low-to-low condition, whereas the high-to-high and high-to-low conditions did not differ significantly. In Experiment 2, an advantage for words with an increasing frequency trajectory was also supported in regression analyses on both lexical decision and naming times for 3,039 items selected from the English Lexicon Project (Balota et al., 2007). This was replicated in Experiment 3, based on a regression analysis of 2,680 words from the British Lexicon Project (BLP; Keuleers, Lacey, Rastle, & Brysbaert, 2012). In all analyses, rated age-of-acquisition also significantly impacted word recognition. Together, the results suggest that the age at which a word is initially learned as well as its frequency trajectory across childhood impact performance in the lexical-decision task. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Lateralization of high-frequency transposed stimuli under conditions of binaural interference
NASA Astrophysics Data System (ADS)
Bernstein, Leslie R.; Trahiotis, Constantine
2005-04-01
The purpose of this study was to determine whether binaural interference would occur if ITD-based extents of laterality were measured using high-frequency transposed stimuli as targets. The results of an earlier study [L. R. Bernstein and C. Trahiotis, J. Acoust. Soc. Am. 116, 3062-3069 (2004)], which focused on threshold-ITDs rather than extents of laterality, suggested that high-frequency transposed stimuli might be immune to binaural interference effects resulting from the addition of a spectrally-remote, low-frequency interferer. In contrast to the earlier findings, the data from this study indicate that high-frequency transposed targets can, indeed, be susceptible to binaural interference. High-frequency transposed targets, even when presented along with an interferer, yielded greater extents of ITD-based laterality than did Gaussian noise targets presented in isolation. That is, the enhanced potency of ITDs conveyed by transposed stimuli persisted even in the presence of a low-frequency interferer. Predictions made using an extension of the model of Heller and Trahiotis [L. M. Heller and C. Trahiotis, J. Acoust. Soc. Am. 99, 3632-3637 (1996)] accounted well for binaural interference obtained with conventional Gaussian noise targets but generally over-predicted the amounts of interference found with the transposed targets.
Electromagnetic inhibition of high frequency thermal bonding machine
NASA Astrophysics Data System (ADS)
He, Hong; Zhang, Qing-qing; Li, Hang; Zhang, Da-jian; Hou, Ming-feng; Zhu, Xian-wei
2011-12-01
The traditional high frequency thermal bonding machine had serious radiation problems at dominant frequency, two times frequency and three times frequency. Combining with its working principle, the problems of electromagnetic compatibility were studied, three following measures were adopted: 1.At the head part of the high frequency thermal bonding machine, resonant circuit attenuator was designed. The notch groove and reaction field can make the radiation being undermined or absorbed; 2.The electromagnetic radiation shielding was made for the high frequency copper power feeder; 3.Redesigned the high-frequency oscillator circuit to reduce the output of harmonic oscillator. The test results showed that these measures can make the output according with the national standard of electromagnetic compatibility (GB4824-2004-2A), the problems of electromagnetic radiation leakage can be solved, and good social, environmental and economic benefits would be brought.
Li, Jiang; Meng, Xiang-Min; Li, Ru-Yi; Zhang, Ru; Zhang, Zheng; Du, Yi-Feng
2016-10-01
Studies have confirmed that low-frequency repetitive transcranial magnetic stimulation can decrease the activity of cortical neurons, and high-frequency repetitive transcranial magnetic stimulation can increase the excitability of cortical neurons. However, there are few studies concerning the use of different frequencies of repetitive transcranial magnetic stimulation on the recovery of upper-limb motor function after cerebral infarction. We hypothesized that different frequencies of repetitive transcranial magnetic stimulation in patients with cerebral infarction would produce different effects on the recovery of upper-limb motor function. This study enrolled 127 patients with upper-limb dysfunction during the subacute phase of cerebral infarction. These patients were randomly assigned to three groups. The low-frequency group comprised 42 patients who were treated with 1 Hz repetitive transcranial magnetic stimulation on the contralateral hemisphere primary motor cortex (M1). The high-frequency group comprised 43 patients who were treated with 10 Hz repetitive transcranial magnetic stimulation on ipsilateral M1. Finally, the sham group comprised 42 patients who were treated with 10 Hz of false stimulation on ipsilateral M1. A total of 135 seconds of stimulation was applied in the sham group and high-frequency group. At 2 weeks after treatment, cortical latency of motor-evoked potentials and central motor conduction time were significantly lower compared with before treatment. Moreover, motor function scores were significantly improved. The above indices for the low- and high-frequency groups were significantly different compared with the sham group. However, there was no significant difference between the low- and high-frequency groups. The results show that low- and high-frequency repetitive transcranial magnetic stimulation can similarly improve upper-limb motor function in patients with cerebral infarction.
Kellam, Barbara; Bhatia, Jatinder
2009-08-01
Few noise measurement studies in the neonatal intensive care unit have reported sound frequencies within incubators. Sound frequencies within incubators are markedly different from sound frequencies within the gravid uterus. This article reports the results of sound spectral analysis (SSA) within unoccupied incubators under control and treatment conditions. SSA indicated that acoustical foam panels (treatment condition) markedly reduced sound frequencies > or =500 Hz when compared with the control condition. The main findings of this study (a) illustrate the need to monitor high-frequency sound within incubators and (b) indicate one method to reduce atypical sound exposure within incubators.
Sjöblom-Widfeldt, N
1990-01-01
For many years noradrenaline was considered to be the exclusive transmitter released from sympathetic nerves. However, during recent years both ATP and NPY have been suggested to be co-transmitters to noradrenaline in these nerves. The present study aimed to investigate the functional relationship between these suggested transmitters during nerve stimulation with different frequencies and in different extracellular calcium concentrations. Also the importance of the pattern of nerve stimulation and the potentiation of the neurogenic response after a period of high-frequency nerve stimulation were investigated. Contractions caused by nerve stimulation and applied agonists were investigated in segments of small mesenteric arteries from rat. The biophysical, electrophysiological, and pharmacological properties of these vessels are well characterized in previous studies. The rapid contraction caused by a single nerve stimulus, the "single twitch", and the initial, phasic contraction caused by high-frequency nerve stimulation were only slightly affected by alpha-adrenoceptor blockade with prazosin, whereas the tonic response to high-frequency stimulation was markedly reduced. The phasic responses and those to low-frequency nerve stimulation thus appear to be due mainly to a non-adrenergic transmitter. After inhibiting the response to exogenous ATP by alpha beta-methylene ATP, the response to single impulses and to low-frequency nerve stimulation were markedly reduced, while those to high-frequency stimulation were unaffected. This suggests that ATP acts as a true transmitter in sympathetic nerves, being responsible mainly for rapid responses to low-frequency stimulation, and for the initial part of responses to high-frequency stimulation. When alpha beta-methylene ATP and prazosin were given in combination, no contraction was obtained during nerve stimulation at any frequency. However, if in this situation a contraction was induced by e.g. exogenous vasopressin, field stimulation caused a further, slow contraction. This additional response was undoubtedly neurogenic, but required high-frequency nerve stimulation. The response to nerve stimulation was found to be calcium-dependent, the calcium-dependency being more pronounced at low than at high stimulation frequencies. A continuous, high-frequency (8-16 Hz) nerve stimulation could greatly (5-15 fold) enhance the response to subsequent low-frequency nerve stimulation. This potentiation increased with the frequency of the conditioning stimulation and, within limits, with the number of impulses delivered. Also the extracellular calcium concentration during the conditioning stimulation determined the magnitude of the potentiation. This post-tetanic potentiation has many characteristics in common with the post-tetanic potentiation studied in the central and somatomotor nervous system.(ABSTRACT TRUNCATED AT 400 WORDS)
High-frequency filtering of strong-motion records
Douglas, J.; Boore, D.M.
2011-01-01
The influence of noise in strong-motion records is most problematic at low and high frequencies where the signal to noise ratio is commonly low compared to that in the mid-spectrum. The impact of low-frequency noise (5 Hz) on computed pseudo-absolute response spectral accelerations (PSAs). In contrast to the case of low-frequency noise our analysis shows that filtering to remove high-frequency noise is only necessary in certain situations and that PSAs can often be used up to 100 Hz even if much lower high-cut corner frequencies are required to remove the noise. This apparent contradiction can be explained by the fact that PSAs are often controlled by ground accelerations associated with much lower frequencies than the natural frequency of the oscillator because path and site attenuation (often modelled by Q and κ, respectively) have removed the highest frequencies. We demonstrate that if high-cut filters are to be used, then their corner frequencies should be selected on an individual basis, as has been done in a few recent studies.
Beck, Tove K; Jensen, Sidsel; Simmelsgaard, Sonni Hansen; Kjeldsen, Chris; Kidmose, Ulla
2015-08-01
Vegetable intake seems to play a protective role against major lifestyle diseases. Despite this, the Danish population usually eats far less than the recommended daily intake. The present study focused on the intake of 17 coarse vegetables and the potential barriers limiting their intake. The present study drew upon a large Danish survey (n = 1079) to study the intake of coarse vegetables among Danish consumers. Four population clusters were identified based on their intake of 17 different coarse vegetables, and profiled according to hedonics, socio-demographic, health, and food lifestyle factors. The four clusters were characterized by a very low intake frequency of coarse vegetables ('low frequency'), a low intake frequency of coarse vegetables; but high intake frequency of carrots ('carrot eaters'), a moderate coarse vegetable intake frequency and high intake frequency of beetroot ('beetroot eaters'), and a high intake frequency of all coarse vegetables ('high frequency'). There was a relationship between reported liking and reported intake frequency for all tested vegetables. Preference for foods with a sweet, salty or bitter taste, in general, was also identified to be decisive for the reported vegetable intake, as these differed across the clusters. Each cluster had distinct socio-demographic, health and food lifestyle profiles. 'Low frequency' was characterized by uninvolved consumers with lack of interest in food, 'carrot eaters' vegetable intake was driven by health aspects, 'beetroot eaters' were characterized as traditional food consumers, and 'high frequency' were individuals with a strong food engagement and high vegetable liking. 'Low frequency' identified more barriers than other consumer clusters and specifically regarded low availability of pre-cut/prepared coarse vegetables on the market as a barrier. Across all clusters a low culinary knowledge was identified as the main barrier. Copyright © 2015 Elsevier Ltd. All rights reserved.
Burns, John W; Quartana, Phillip J; Bruehl, Stephen; Janssen, Imke; Dugan, Sheila A; Appelhans, Bradley; Matthews, Karen A; Kravitz, Howard M
2015-04-01
Chronic pain may be related to cardiovascular disease (CVD) risk. The current study examined whether persistent bodily pain was related to cardiovascular disease risk factors, whether these effects were moderated by body mass index (BMI), and, if not, whether chronic pain accounted for unique variance in CVD risk factors. Participants were women (N = 2,135) in the Study of Women's Health Across the Nation. A high pain frequency variable (high pain in 0 through 4 assessments) was coded to reflect the frequency of high levels of bodily pain across the first 3 years of the study. Six CVD risk factors and BMI were measured at follow-up year 3. High pain frequency and BMI were correlated significantly with risk factors, although effects for the former were small. Hierarchical multiple regressions revealed high pain frequency × BMI interactions for 5 of 6 CVD risk factors. Dissecting the interactions revealed a similar pattern across 4 risk factors: for women with normal BMI, there was a "dose-response" in which increasing frequency of high pain revealed increasingly worse CVD risk factor levels, whereas for women with obese BMI, high pain frequency was unrelated to risk factors. For obese women, increasing frequency of high pain was associated with higher blood glucose. Although BMI is a well-established CVD risk factor, evaluation of CVD risk level may be improved by considering the incidence of persistent pain, particularly in normal weight women (BMI < 25 kg/m(2)) lower BMI.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... field versus laboratory conditions. While multiple controlled studies of high-frequency cetaceans to... of behavioral response translates to other high-frequency cetaceans (Southall et al., 2007). There... exposures at higher levels. Jacobs and Terhune (2002) observed wild harbor seal reactions to high-frequency...
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Zhang, Y. S.; Ren, A.
1990-01-01
A chamber experiment is conducted to study the propagation of a high-power microwave pulse. The results show that the pulse is experiencing frequency up-shift while ionizing the background air if the initial carrier frequency of the pulse is higher than the electron plasma frequency at the incident boundary. Such a frequency autoconversion process may lead to reflectionless propagation of a high-power microwave pulse through the atmosphere.
Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva
2015-01-01
Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: “Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?” The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace. PMID:27413413
Serial Recall, Word Frequency, and Mixed Lists: The Influence of Item Arrangement
ERIC Educational Resources Information Center
Miller, Leonie M.; Roodenrys, Steven
2012-01-01
Studies of the effect of word frequency in the serial recall task show that lists of high-frequency words are better recalled than lists of low-frequency words; however, when high- and low-frequency words are alternated within a list, there is no difference in the level of recall for the two types of words, and recall is intermediate between lists…
Eddy-driven low-frequency variability: physics and observability through altimetry
NASA Astrophysics Data System (ADS)
Penduff, Thierry; Sérazin, Guillaume; Arbic, Brian; Mueller, Malte; Richman, James G.; Shriver, Jay F.; Morten, Andrew J.; Scott, Robert B.
2015-04-01
Model studies have revealed the propensity of the eddying ocean circulation to generate strong low-frequency variability (LFV) intrinsically, i.e. without low-frequency atmospheric variability. In the present study, gridded satellite altimeter products, idealized quasi-geostrophic (QG) turbulent simulations, and realistic high-resolution global ocean simulations are used to study the spontaneous tendency of mesoscale (relatively high frequency and high wavenumber) kinetic energy to non-linearly cascade towards larger time and space scales. The QG model reveals that large-scale variability, arising from the well-known spatial inverse cascade, is associated with low frequencies. Low-frequency, low-wavenumber energy is maintained primarily by nonlinearities in the QG model, with forcing (by large-scale shear) and friction playing secondary roles. In realistic simulations, nonlinearities also generally drive kinetic energy to low frequencies and low wavenumbers. In some, but not all, regions of the gridded altimeter product, surface kinetic energy is also found to cascade toward low frequencies. Exercises conducted with the realistic model suggest that the spatial and temporal filtering inherent in the construction of gridded satellite altimeter maps may contribute to the discrepancies seen in some regions between the direction of frequency cascade in models versus gridded altimeter maps. Finally, the range of frequencies that are highly energized and engaged these cascades appears much greater than the range of highly energized and engaged wavenumbers. Global eddying simulations, performed in the context of the CHAOCEAN project in collaboration with the CAREER project, provide estimates of the range of timescales that these oceanic nonlinearities are likely to feed without external variability.
Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P; Elia, Maurizio
2014-08-01
This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and investigating the real efficacy of high-frequency repetitive transcranial magnetic stimulation by comparing three kinds of treatments (high-frequency repetitive transcranial magnetic stimulation, a traditional eye-hand integration training, and both treatments combined). Results showed a significant increase in eye-hand performances only when high-frequency repetitive transcranial magnetic stimulation was delivered on the left premotor cortex; a persistent improvement up to 1 h after the end of the stimulation; better outcomes in the treatment combining high-frequency repetitive transcranial magnetic stimulation and eye-hand integration training. Based on these preliminary findings, further evaluations on the usefulness of high-frequency repetitive transcranial magnetic stimulation in rehabilitation of children with autism are strongly recommended. © The Author(s) 2013.
Tse, Chun-Yu; Gordon, Brian A; Fabiani, Monica; Gratton, Gabriele
2010-09-01
Relatively high frequency activity (>4Hz) carries important information about the state of the brain or its response to high frequency events. The electroencephalogram (EEG) is commonly used to study these changes because it possesses high temporal resolution and a good signal-to-noise ratio. However, it provides limited spatial information. Non-invasive fast optical signals (FOS) have been proposed as a neuroimaging tool combining spatial and temporal resolution. Yet, this technique has not been applied to study high frequency brain oscillations because of its relatively low signal-to-noise ratio. Here we investigate the sensitivity of FOS to relatively high-frequency brain oscillations. We measured the steady-state optical response elicited in medial and lateral occipital cortex by checkerboard reversals occurring at 4, 6, and 8Hz in younger and older adults. Stimulus-dependent oscillations were observed at the predicted stimulation frequency. In addition, in the younger adults the FOS steady-state response was smaller in lateral than medial areas, whereas in the older adults it was reversed in these two cortical regions. This may reflect diminished top-down inhibitory control in the older adults. The results indicate that FOS can be used to study the modulation of relatively high-frequency brain oscillations in adjacent cortical regions. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Stamoulis, Catherine; Schomer, Donald L.; Chang, Bernard S.
2013-01-01
How a seizure terminates is still under-studied and, despite its clinical importance, remains an obscure phase of seizure evolution. Recent studies of seizure-related scalp EEGs at frequencies >100 Hz suggest that neural activity, in the form of oscillations and/or neuronal network interactions, may play an important role in preictal/ictal seizure evolution [2, 31]. However, the role of high-frequency activity in seizure termination, is unknown, if it exists at all. Using information theoretic measures of network coordination, this study investigated ictal and immediate postictal neurodynamic interactions encoded in scalp EEGs from a relatively small sample of 8 patients with focal epilepsy and multiple seizures originating in temporal and/or frontal brain regions, at frequencies ≤100 Hz and >100 Hz, respectively. Despite some heterogeneity in the dynamics of these interactions, consistent patterns were also estimated. Specifically, in several seizures, linear or non-linear increase in high-frequency neuronal coordination during ictal intervals, coincided with a corresponding decrease in coordination at frequencies <100 Hz, suggesting a potential interference role of high-frequency activity, to disrupt abnormal ictal synchrony at lower frequencies. These changes in network synchrony started at least 20–30 sec prior to seizure offset, depending on the seizure duration. Opposite patterns were estimated at frequencies ≤100 Hz in several seizures. These results raise the possibility that high-frequency interference may occur in the form of progressive network coordination during the ictal interval, which continues during the postictal interval. This may be one of several possible mechanisms that facilitate seizure termination. In fact, inhibition of pairwise interactions between EEGs by other signals in their spatial neighborhood, quantified by negative interaction information, was estimated at frequencies ≤100 Hz, at least in some seizures. PMID:23608198
Doucet, Barbara M.; Griffin, Lisa
2014-01-01
Introduction The optimal parameters of neuromuscular electrical stimulation (NMES) for recovery of hand function following stroke are not known. This clinical pilot study examined whether higher or lower frequencies are more effective for improving fine motor control of the hand in a chronic post-stroke population. Methods A one-month, 4x/week in-home regimen of either a high frequency (40Hz) or low frequency (20Hz) NMES program was applied to the hemiplegic thenar muscles of 16 persons with chronic stroke. Participants were identified a priori as having a low level of function (LF) or a high level of function (HF). Outcome measures of strength, dexterity, and endurance were measured before and after participation in the regimen. Results LF subjects showed no significant changes with either the high or the low frequency NMES regimen. HF subjects showed significant changes in strength, dexterity and endurance. Within this group, higher frequencies of stimulation yielded strength gains and increased motor activation; lower frequencies impacted dexterity and endurance. Conclusions The results suggest that higher frequencies of stimulation could be more effective in improving strength and motor activation properties and that lower frequencies may impact coordination and endurance changes; results also indicate that persons with a higher functional level of recovery may respond more favorably to NMES regimens, but further study with larger patient groups is warranted. PMID:23893829
Distributed measurement of acoustic vibration location with frequency multiplexed phase-OTDR
NASA Astrophysics Data System (ADS)
Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya
2017-07-01
All-fiber distributed vibration sensing is attracting attention in relation to structural health monitoring because it is cost effective, offers high coverage of the monitored area and can detect various structural problems. And in particular the demand for high-speed vibration sensing operating at more than 10 kHz has increased because high frequency vibration indicates high energy and severe trouble in the monitored object. Optical fiber vibration sensing with phase-sensitive optical time domain reflectometry (phase-OTDR) has long been studied because it can be used for distributed vibration sensing in optical fiber. However, pulse reflectometry such as OTDR cannot measure high-frequency vibration whose cycle is shorter than the repetition time of the OTDR. That is, the maximum detectable frequency depends on fiber length. In this paper, we describe a vibration sensing technique with frequency-multiplexed OTDR that can detect the entire distribution of a high-frequency vibration thus allowing us to locate a high-speed vibration point. We can measure the position, frequency and dynamic change of a high-frequency vibration whose cycle is shorter than the repetition time. Both frequency and position are visualized simultaneously for a 5-km fiber with an 80-kHz frequency response and a 20-m spatial resolution.
Schneider, William; MacKenzie, Michael; Waldfogel, Jane; Brooks-Gunn, Jeanne
2015-06-01
This paper provides new evidence on parent and child reporting of corporal punishment, drawing on data from the Fragile Families and Child Wellbeing Study, a birth cohort study of families in 20 medium to large US cities. In separate interviews, 9 year olds and their mothers (N=1,180 families) were asked about the frequency of corporal punishment in the past year. Mothers and children were asked questions with slightly different response categorize which are harmonized in our analysis. Overall, children reported more high frequency corporal punishment (spanking or other physical punishment more than 10 times per year) than their mothers did; this discrepancy was seen in both African-American and Hispanic families (but not White families), and was evident for both boys and girls. These results suggest that reporting of frequency of corporal punishment is sensitive to the identity of the reporter and that in particular child reports may reveal more high frequency punishment than maternal reports do. However, predictors of high frequency punishment were similar regardless of reporter identity; in both cases, risk of high frequency punishment was higher when the child was African-American or had high previous levels of behavior problems.
Schneider, William; MacKenzie, Michael; Waldfogel, Jane; Brooks-Gunn, Jeanne
2017-01-01
This paper provides new evidence on parent and child reporting of corporal punishment, drawing on data from the Fragile Families and Child Wellbeing Study, a birth cohort study of families in 20 medium to large US cities. In separate interviews, 9 year olds and their mothers (N=1,180 families) were asked about the frequency of corporal punishment in the past year. Mothers and children were asked questions with slightly different response categorize which are harmonized in our analysis. Overall, children reported more high frequency corporal punishment (spanking or other physical punishment more than 10 times per year) than their mothers did; this discrepancy was seen in both African-American and Hispanic families (but not White families), and was evident for both boys and girls. These results suggest that reporting of frequency of corporal punishment is sensitive to the identity of the reporter and that in particular child reports may reveal more high frequency punishment than maternal reports do. However, predictors of high frequency punishment were similar regardless of reporter identity; in both cases, risk of high frequency punishment was higher when the child was African-American or had high previous levels of behavior problems. PMID:28386302
Improving mental task classification by adding high frequency band information.
Zhang, Li; He, Wei; He, Chuanhong; Wang, Ping
2010-02-01
Features extracted from delta, theta, alpha, beta and gamma bands spanning low frequency range are commonly used to classify scalp-recorded electroencephalogram (EEG) for designing brain-computer interface (BCI) and higher frequencies are often neglected as noise. In this paper, we implemented an experimental validation to demonstrate that high frequency components could provide helpful information for improving the performance of the mental task based BCI. Electromyography (EMG) and electrooculography (EOG) artifacts were removed by using blind source separation (BSS) techniques. Frequency band powers and asymmetry ratios from the high frequency band (40-100 Hz) together with those from the lower frequency bands were used to represent EEG features. Finally, Fisher discriminant analysis (FDA) combining with Mahalanobis distance were used as the classifier. In this study, four types of classifications were performed using EEG signals recorded from four subjects during five mental tasks. We obtained significantly higher classification accuracy by adding the high frequency band features compared to using the low frequency bands alone, which demonstrated that the information in high frequency components from scalp-recorded EEG is valuable for the mental task based BCI.
Slabbekoorn, Hans; Otter, Ken A.
2017-01-01
Low-frequency urban noise can interfere with avian communication through masking. Some species are able to shift the frequency of their vocalizations upwards in noisy conditions, which may reduce the effects of masking. However, results from playback studies investigating whether or not such vocal changes improve audibility in noisy conditions are not clear; the responses of free-ranging individuals to shifted signals are potentially confounded by functional trade-offs between masking-related audibility and frequency-dependent signal quality. Black-capped chickadees (Poecile atricapillus) naturally sing their songs at several different frequencies as they pitch-shift to match conspecifics during song-matching contests. They are also known to switch to higher song frequencies in response to experimental noise exposure. Each male produces both high- and low-frequency songs and absolute frequency is not a signal of aggression or dominance, making this an interesting species in which to test whether higher-frequency songs are more audible than lower-frequency songs in noisy conditions. We conducted playback studies across southern and central British Columbia, Canada, using paired song stimuli (high- vs low-frequency songs, n = 24 pairs) embedded in synthetic background noise created to match typical urban sound profiles. Over the course of each playback, the signal-to-noise ratio of the song stimuli was gradually increased by raising the amplitude of the song stimuli while maintaining background noise at a constant amplitude. We evaluated variation in how quickly and aggressively territorial males reacted to each of the paired stimuli. We found that males responded more quickly to playbacks of high- than low-frequency songs when high-frequency songs were presented first, but not when low-frequency songs were first. This difference may be explained by high-frequency songs being more audible combined with a carry-over effect resulting in slower responses to the second stimulus due to habituation. We observed no difference in overall aggression between stimuli. These results suggest that high-frequency songs may be more audible under noisy conditions. PMID:28462051
Hornsby, Benjamin W. Y.; Johnson, Earl E.; Picou, Erin
2011-01-01
Objectives The purpose of this study was to examine the effects of degree and configuration of hearing loss on the use of, and benefit from, information in amplified high- and low-frequency speech presented in background noise. Design Sixty-two adults with a wide range of high- and low-frequency sensorineural hearing loss (5–115+ dB HL) participated. To examine the contribution of speech information in different frequency regions, speech understanding in noise was assessed in multiple low- and high-pass filter conditions, as well as a band-pass (713–3534 Hz) and wideband (143–8976 Hz) condition. To increase audibility over a wide frequency range, speech and noise were amplified based on each individual’s hearing loss. A stepwise multiple linear regression approach was used to examine the contribution of several factors to 1) absolute performance in each filter condition and 2) the change in performance with the addition of amplified high- and low-frequency speech components. Results Results from the regression analysis showed that degree of hearing loss was the strongest predictor of absolute performance for low- and high-pass filtered speech materials. In addition, configuration of hearing loss affected both absolute performance for severely low-pass filtered speech and benefit from extending high-frequency (3534–8976 Hz) bandwidth. Specifically, individuals with steeply sloping high-frequency losses made better use of low-pass filtered speech information than individuals with similar low-frequency thresholds but less high-frequency loss. In contrast, given similar high-frequency thresholds, individuals with flat hearing losses received more benefit from extending high-frequency bandwidth than individuals with more sloping losses. Conclusions Consistent with previous work, benefit from speech information in a given frequency region generally decreases as degree of hearing loss in that frequency region increases. However, given a similar degree of loss, the configuration of hearing loss also affects the ability to use speech information in different frequency regions. Except for individuals with steeply sloping high-frequency losses, providing high-frequency amplification (3534–8976 Hz) had either a beneficial effect on, or did not significantly degrade, speech understanding. These findings highlight the importance of extended high-frequency amplification for listeners with a wide range of high-frequency hearing losses, when seeking to maximize intelligibility. PMID:21336138
The low-frequency encoding disadvantage: Word frequency affects processing demands.
Diana, Rachel A; Reder, Lynne M
2006-07-01
Low-frequency words produce more hits and fewer false alarms than high-frequency words in a recognition task. The low-frequency hit rate advantage has sometimes been attributed to processes that operate during the recognition test (e.g., L. M. Reder et al., 2000). When tasks other than recognition, such as recall, cued recall, or associative recognition, are used, the effects seem to contradict a low-frequency advantage in memory. Four experiments are presented to support the claim that in addition to the advantage of low-frequency words at retrieval, there is a low-frequency disadvantage during encoding. That is, low-frequency words require more processing resources to be encoded episodically than high-frequency words. Under encoding conditions in which processing resources are limited, low-frequency words show a larger decrement in recognition than high-frequency words. Also, studying items (pictures and words of varying frequencies) along with low-frequency words reduces performance for those stimuli. Copyright 2006 APA, all rights reserved.
Wensveen, Paul J; Huijser, Léonie A E; Hoek, Lean; Kastelein, Ronald A
2016-01-01
Loudness perception can be studied based on the assumption that sounds of equal loudness elicit equal reaction time (RT; or "response latency"). We measured the underwater RTs of a harbor porpoise to narrowband frequency-modulated sounds and constructed six equal-latency contours. The contours paralleled the audiogram at low sensation levels (high RTs). At high-sensation levels, contours flattened between 0.5 and 31.5 kHz but dropped substantially (RTs shortened) beyond those frequencies. This study suggests that equal-latency-based frequency weighting can emulate noise perception in porpoises for low and middle frequencies but that the RT-loudness correlation is relatively weak for very high frequencies.
High-frequency hearing impairment assessed with cochlear microphonics.
Zhang, Ming
2012-09-01
Cochlear microphonic (CM) measurements may potentially become a supplementary approach to otoacoustic emission (OAE) measurements for assessing low-frequency cochlear functions in the clinic. The objective of this study was to investigate the measurement of CMs in subjects with high-frequency hearing loss. Currently, CMs can be measured using electrocochleography (ECochG or ECoG) techniques. Both CMs and OAEs are cochlear responses, while auditory brainstem responses (ABRs) are not. However, there are inherent limitations associated with OAE measurements such as acoustic noise, which can conceal low-frequency OAEs measured in the clinic. However, CM measurements may not have these limitations. CMs were measured in human subjects using an ear canal electrode. The CMs were compared between the high-frequency hearing loss group and the normal-hearing control group. Distortion product OAEs (DPOAEs) and audiogram were also measured. The DPOAE and audiogram measurements indicate that the subjects were correctly selected for the two groups. Low-frequency CM waveforms (CMWs) can be measured using ear canal electrodes in high-frequency hearing loss subjects. The difference in amplitudes of CMWs between the high-frequency hearing loss group and the normal-hearing group is insignificant at low frequencies but significant at high frequencies.
Chang, Jiwon; Ryou, Namhyung; Jun, Hyung Jin; Hwang, Soon Young; Song, Jae-Jun; Chae, Sung Won
2016-01-01
Objectives In the present study, we aimed to determine the effect of both active and passive smoking on the prevalence of the hearing impairment and the hearing thresholds in different age groups through the analysis of data collected from the Korea National Health and Nutrition Examination Survey (KNHANES). Study Design Cross-sectional epidemiological study. Methods The KNHANES is an ongoing population study that started in 1998. We included a total of 12,935 participants aged ≥19 years in the KNHANES, from 2010 to 2012, in the present study. Pure-tone audiometric (PTA) testing was conducted and the frequencies tested were 0.5, 1, 2, 3, 4, and 6 kHz. Smoking status was categorized into three groups; current smoking group, passive smoking group and non-smoking group. Results In the current smoking group, the prevalence of speech-frequency bilateral hearing impairment was increased in ages of 40−69, and the rate of high frequency bilateral hearing impairment was elevated in ages of 30−79. When we investigated the impact of smoking on hearing thresholds, we found that the current smoking group had significantly increased hearing thresholds compared to the passive smoking group and non-smoking groups, across all ages in both speech-relevant and high frequencies. The passive smoking group did not have an elevated prevalence of either speech-frequency bilateral hearing impairment or high frequency bilateral hearing impairment, except in ages of 40s. However, the passive smoking group had higher hearing thresholds than the non-smoking group in the 30s and 40s age groups. Conclusion Current smoking was associated with hearing impairment in both speech-relevant frequency and high frequency across all ages. However, except in the ages of 40s, passive smoking was not related to hearing impairment in either speech-relevant or high frequencies. PMID:26756932
Evaluation of factors associated with severe and frequent back pain in high school athletes.
Noll, Matias; Silveira, Erika Aparecida; Avelar, Ivan Silveira de
2017-01-01
Several studies have shown that half of all young athletes experience back pain (BP). However, high intensity and frequency of BP may be harmful, and the factors associated with BP severity have not been investigated in detail. Here, we investigated the factors associated with a high intensity and high frequency of BP in high school athletes. We included 251 athletes (173 boys and 78 girls [14-20 years old]) in this cross-sectional study. The dependent variables were a high frequency and high intensity of BP, and the independent variables were demographic, socioeconomic, psychosocial, hereditary, anthropometric, behavioural, and postural factors and the level of exercise. The effect measure is presented as prevalence ratio (PR) with 95% confidence interval (CI). Of 251 athletes, 104 reported BP; thus, only these athletes were included in the present analysis. Results of multivariable analysis showed an association between high BP intensity and time spent using a computer (PR: 1.15, CI: 1.01-1.33), posture while writing (PR: 1.41, CI: 1.27-1.58), and posture while using a computer (PR: 1.39, CI: 1.26-1.54). Multivariable analysis also revealed an association of high BP frequency with studying in bed (PR: 1.19, CI: 1.01-1.40) and the method of carrying a backpack (PR: 1.19, CI: 1.01-1.40). In conclusion, we found that behavioural and postural factors are associated with a high intensity and frequency of BP. To the best of our knowledge, this study is the first to compare different intensities and frequencies of BP, and our results may help physicians and coaches to better understand BP in high school athletes.
Evaluation of factors associated with severe and frequent back pain in high school athletes
Noll, Matias; Silveira, Erika Aparecida; de Avelar, Ivan Silveira
2017-01-01
Several studies have shown that half of all young athletes experience back pain (BP). However, high intensity and frequency of BP may be harmful, and the factors associated with BP severity have not been investigated in detail. Here, we investigated the factors associated with a high intensity and high frequency of BP in high school athletes. We included 251 athletes (173 boys and 78 girls [14–20 years old]) in this cross-sectional study. The dependent variables were a high frequency and high intensity of BP, and the independent variables were demographic, socioeconomic, psychosocial, hereditary, anthropometric, behavioural, and postural factors and the level of exercise. The effect measure is presented as prevalence ratio (PR) with 95% confidence interval (CI). Of 251 athletes, 104 reported BP; thus, only these athletes were included in the present analysis. Results of multivariable analysis showed an association between high BP intensity and time spent using a computer (PR: 1.15, CI: 1.01–1.33), posture while writing (PR: 1.41, CI: 1.27–1.58), and posture while using a computer (PR: 1.39, CI: 1.26–1.54). Multivariable analysis also revealed an association of high BP frequency with studying in bed (PR: 1.19, CI: 1.01–1.40) and the method of carrying a backpack (PR: 1.19, CI: 1.01–1.40). In conclusion, we found that behavioural and postural factors are associated with a high intensity and frequency of BP. To the best of our knowledge, this study is the first to compare different intensities and frequencies of BP, and our results may help physicians and coaches to better understand BP in high school athletes. PMID:28222141
Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong
2014-07-01
The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P < 0.05). The detection rate of each pulmonary vein when employing low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.
Study of high performance alloy electroforming
NASA Technical Reports Server (NTRS)
Malone, G. A.
1985-01-01
More panels electroformed with intentional variations of pulse plating parameters are being made. Pulse plating frequency was noted to have a significant effect regarding mechanical properties. The use of a high pulse frequency (assuming fixed duty cycles) results in an increase in ductility and a decrease in ultimate and yield strengths. Electroforming to intermediate frequencies is being done to obtain the best possible combination of ductility and strength. Results of some tests from high frequency specimens are tabulated.
Jessen, Sarah; Grossmann, Tobias
2017-01-01
Enhanced attention to fear expressions in adults is primarily driven by information from low as opposed to high spatial frequencies contained in faces. However, little is known about the role of spatial frequency information in emotion processing during infancy. In the present study, we examined the role of low compared to high spatial frequencies in the processing of happy and fearful facial expressions by using filtered face stimuli and measuring event-related brain potentials (ERPs) in 7-month-old infants ( N = 26). Our results revealed that infants' brains discriminated between emotional facial expressions containing high but not between expressions containing low spatial frequencies. Specifically, happy faces containing high spatial frequencies elicited a smaller Nc amplitude than fearful faces containing high spatial frequencies and happy and fearful faces containing low spatial frequencies. Our results demonstrate that already in infancy spatial frequency content influences the processing of facial emotions. Furthermore, we observed that fearful facial expressions elicited a comparable Nc response for high and low spatial frequencies, suggesting a robust detection of fearful faces irrespective of spatial frequency content, whereas the detection of happy facial expressions was contingent upon frequency content. In summary, these data provide new insights into the neural processing of facial emotions in early development by highlighting the differential role played by spatial frequencies in the detection of fear and happiness.
High-frequency energy in singing and speech
NASA Astrophysics Data System (ADS)
Monson, Brian Bruce
While human speech and the human voice generate acoustical energy up to (and beyond) 20 kHz, the energy above approximately 5 kHz has been largely neglected. Evidence is accruing that this high-frequency energy contains perceptual information relevant to speech and voice, including percepts of quality, localization, and intelligibility. The present research was an initial step in the long-range goal of characterizing high-frequency energy in singing voice and speech, with particular regard for its perceptual role and its potential for modification during voice and speech production. In this study, a database of high-fidelity recordings of talkers was created and used for a broad acoustical analysis and general characterization of high-frequency energy, as well as specific characterization of phoneme category, voice and speech intensity level, and mode of production (speech versus singing) by high-frequency energy content. Directionality of radiation of high-frequency energy from the mouth was also examined. The recordings were used for perceptual experiments wherein listeners were asked to discriminate between speech and voice samples that differed only in high-frequency energy content. Listeners were also subjected to gender discrimination tasks, mode-of-production discrimination tasks, and transcription tasks with samples of speech and singing that contained only high-frequency content. The combination of these experiments has revealed that (1) human listeners are able to detect very subtle level changes in high-frequency energy, and (2) human listeners are able to extract significant perceptual information from high-frequency energy.
Minimal basilar membrane motion in low-frequency hearing
Warren, Rebecca L.; Ramamoorthy, Sripriya; Ciganović, Nikola; Zhang, Yuan; Wilson, Teresa M.; Petrie, Tracy; Wang, Ruikang K.; Jacques, Steven L.; Reichenbach, Tobias; Nuttall, Alfred L.; Fridberger, Anders
2016-01-01
Low-frequency hearing is critically important for speech and music perception, but no mechanical measurements have previously been available from inner ears with intact low-frequency parts. These regions of the cochlea may function in ways different from the extensively studied high-frequency regions, where the sensory outer hair cells produce force that greatly increases the sound-evoked vibrations of the basilar membrane. We used laser interferometry in vitro and optical coherence tomography in vivo to study the low-frequency part of the guinea pig cochlea, and found that sound stimulation caused motion of a minimal portion of the basilar membrane. Outside the region of peak movement, an exponential decline in motion amplitude occurred across the basilar membrane. The moving region had different dependence on stimulus frequency than the vibrations measured near the mechanosensitive stereocilia. This behavior differs substantially from the behavior found in the extensively studied high-frequency regions of the cochlea. PMID:27407145
NASA Technical Reports Server (NTRS)
Kraft, R. E.; Yu, J.; Kwan, H. W.
1999-01-01
The primary purpose of this study is to develop improved models for the acoustic impedance of treatment panels at high frequencies, for application to subscale treatment designs. Effects that cause significant deviation of the impedance from simple geometric scaling are examined in detail, an improved high-frequency impedance model is developed, and the improved model is correlated with high-frequency impedance measurements. Only single-degree-of-freedom honeycomb sandwich resonator panels with either perforated sheet or "linear" wiremesh faceplates are considered. The objective is to understand those effects that cause the simple single-degree-of- freedom resonator panels to deviate at the higher-scaled frequency from the impedance that would be obtained at the corresponding full-scale frequency. This will allow the subscale panel to be designed to achieve a specified impedance spectrum over at least a limited range of frequencies. An advanced impedance prediction model has been developed that accounts for some of the known effects at high frequency that have previously been ignored as a small source of error for full-scale frequency ranges.
Study of Colombia North Wiwa El Encanto Amerindians HLA- genes: Pacific Islanders relatedness.
Arnaiz-Villena, Antonio; Palacio-Grüber, Jose; Juarez, Ignacio; Muñiz, Ester; Hernández, Ennio; Bayona, Brayan; Campos, Cristina; Nuñez, Jorge; Lopez-Nares, Adrian; Martin-Villa, Manuel; Silvera, Carlos
2018-07-01
We have studied Wiwa/Sanja Amerindians HLA-A, -B, -C, -DRB1 and DQB1 allele frequencies and extended haplotypes in 52 unrelated individuals from "El Encanto" town at Guanachaca riverside. High frequency alleles were in general present in other Amerindian populations. Also, three extended haplotypes and eight ones were respectively both "new found" and already described in Amerindians from North, Central and South America, including Lakota-Sioux, Mayas, Teeneks, Quechua and Aymaras. Analyses of HLA-A*24:02 and -C*01:02 Wiwa high frequency alleles suggested a specific relatedness with another Amerindian and Pacific Islander ethnic groups (these two particular alleles bearing in high frequencies); they include New Zealand Maoris, Taiwanese, Japanese, Papua New Guinea, and Samoans among others. This may indicate that selective forces are maintaining these two alleles high frequency within this wide American/Pacific area. Copyright © 2018. Published by Elsevier Inc.
Does Phonology Play a Role When Skilled Readers Read High-Frequency Words? Evidence from ERPs
ERIC Educational Resources Information Center
Newman, Randy Lynn; Jared, Debra; Haigh, Corinne A.
2012-01-01
We used event-related brain potentials to clarify the role of phonology in activating the meanings of high-frequency words during skilled silent reading. Target homophones ("meet") in sentences such as "The students arranged to meet in the library to study" were replaced on some trials by either a high-frequency homophone mate…
ERIC Educational Resources Information Center
Sekhar, Deepa L.; Zalewski, Thomas R.; Beiler, Jessica S.; Czarnecki, Beth; Barr, Ashley L.; King, Tonya S.; Paul, Ian M.
2016-01-01
High frequency hearing loss (HFHL), often related to hazardous noise, affects one in six U.S. adolescents. Yet, only 20 states include school-based hearing screens for adolescents. Only six states test multiple high frequencies. Study objectives were to (1) compare the sensitivity of state school-based hearing screens for adolescents to gold…
Frank, T
2001-04-01
The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.
Isomura, Akihiro; Hörning, Marcel; Agladze, Konstantin; Yoshikawa, Kenichi
2008-12-01
The unpinning of spiral waves by the application of high-frequency wave trains was studied in cultured cardiac myocytes. Successful unpinning was observed when the frequency of the paced waves exceeded a critical level. The unpinning process was analyzed by a numerical simulation with a model of cardiac tissue. The mechanism of unpinning by high-frequency stimuli is discussed in terms of local entrainment failure, through a reduction of the two-dimensional spatial characteristics into one dimension.
McConnell, George C; So, Rosa Q; Hilliard, Justin D; Lopomo, Paola; Grill, Warren M
2012-11-07
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for the motor symptoms of Parkinson's disease (PD). The effects of DBS depend strongly on stimulation frequency: high frequencies (>90 Hz) improve motor symptoms, while low frequencies (<50 Hz) are either ineffective or exacerbate symptoms. The neuronal basis for these frequency-dependent effects of DBS is unclear. The effects of different frequencies of STN-DBS on behavior and single-unit neuronal activity in the basal ganglia were studied in the unilateral 6-hydroxydopamine lesioned rat model of PD. Only high-frequency DBS reversed motor symptoms, and the effectiveness of DBS depended strongly on stimulation frequency in a manner reminiscent of its clinical effects in persons with PD. Quantification of single-unit activity in the globus pallidus externa (GPe) and substantia nigra reticulata (SNr) revealed that high-frequency DBS, but not low-frequency DBS, reduced pathological low-frequency oscillations (∼9 Hz) and entrained neurons to fire at the stimulation frequency. Similarly, the coherence between simultaneously recorded pairs of neurons within and across GPe and SNr shifted from the pathological low-frequency band to the stimulation frequency during high-frequency DBS, but not during low-frequency DBS. The changes in firing patterns in basal ganglia neurons were not correlated with changes in firing rate. These results indicate that high-frequency DBS is more effective than low-frequency DBS, not as a result of changes in firing rate, but rather due to its ability to replace pathological low-frequency network oscillations with a regularized pattern of neuronal firing.
McConnell, George C.; So, Rosa Q.; Hilliard, Justin D; Lopomo, Paola; Grill, Warren M.
2012-01-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for the motor symptoms of Parkinson’s disease (PD). The effects of DBS depend strongly on stimulation frequency: high frequencies (>90Hz) improve motor symptoms, while low frequencies (<50Hz) are either ineffective or exacerbate symptoms. The neuronal basis for these frequency-dependent effects of DBS is unclear. The effects of different frequencies of STN-DBS on behavior and single-unit neuronal activity in the basal ganglia were studied in the unilateral 6-hydroxydopamine lesioned rat model of PD. Only high frequency DBS reversed motor symptoms and the effectiveness of DBS depended strongly on stimulation frequency in a manner reminiscent of its clinical effects in persons with PD. Quantification of single-unit activity in the globus pallidus externa (GPe) and substantia nigra reticulata (SNr) revealed that high frequency DBS, but not low frequency DBS, reduced pathological low frequency oscillations (~9Hz) and entrained neurons to fire at the stimulation frequency. Similarly, the coherence between simultaneously recorded pairs of neurons within and across GPe and SNr shifted from the pathological low frequency band to the stimulation frequency during high frequency DBS, but not during low frequency DBS. The changes in firing patterns in basal ganglia neurons were not correlated with changes in firing rate. These results indicate that high frequency DBS is more effective than low frequency DBS, not as a result of changes in firing rate, but rather due to its ability to replace pathological low frequency network oscillations with a regularized pattern of neuronal firing. PMID:23136407
High frequency oscillations are associated with cognitive processing in human recognition memory.
Kucewicz, Michal T; Cimbalnik, Jan; Matsumoto, Joseph Y; Brinkmann, Benjamin H; Bower, Mark R; Vasoli, Vincent; Sulc, Vlastimil; Meyer, Fred; Marsh, W R; Stead, S M; Worrell, Gregory A
2014-08-01
High frequency oscillations are associated with normal brain function, but also increasingly recognized as potential biomarkers of the epileptogenic brain. Their role in human cognition has been predominantly studied in classical gamma frequencies (30-100 Hz), which reflect neuronal network coordination involved in attention, learning and memory. Invasive brain recordings in animals and humans demonstrate that physiological oscillations extend beyond the gamma frequency range, but their function in human cognitive processing has not been fully elucidated. Here we investigate high frequency oscillations spanning the high gamma (50-125 Hz), ripple (125-250 Hz) and fast ripple (250-500 Hz) frequency bands using intracranial recordings from 12 patients (five males and seven females, age 21-63 years) during memory encoding and recall of a series of affectively charged images. Presentation of the images induced high frequency oscillations in all three studied bands within the primary visual, limbic and higher order cortical regions in a sequence consistent with the visual processing stream. These induced oscillations were detected on individual electrodes localized in the amygdala, hippocampus and specific neocortical areas, revealing discrete oscillations of characteristic frequency, duration and latency from image presentation. Memory encoding and recall significantly modulated the number of induced high gamma, ripple and fast ripple detections in the studied structures, which was greater in the primary sensory areas during the encoding (Wilcoxon rank sum test, P = 0.002) and in the higher-order cortical association areas during the recall (Wilcoxon rank sum test, P = 0.001) of memorized images. Furthermore, the induced high gamma, ripple and fast ripple responses discriminated the encoded and the affectively charged images. In summary, our results show that high frequency oscillations, spanning a wide range of frequencies, are associated with memory processing and generated along distributed cortical and limbic brain regions. These findings support an important role for fast network synchronization in human cognition and extend our understanding of normal physiological brain activity during memory processing. © The Author (2014). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhao, Hongyu; Xu, Yan; Wang, Fang; Jiang, Jiang; Zhang, Xiaohui
2015-12-01
Existing studies have found that parent-adolescent conflict frequency and conflict coping tactics influence adolescent family satisfaction and self-satisfaction under the background of Western culture. However, due to differences between Eastern and Western cultures, it is unknown whether previous results of the Western population can be extended to Chinese adolescents. The present study investigated grade differences in parent-adolescent conflict frequency and conflict coping tactics and examined the moderating effects of conflict coping tactics on the relationships between conflict frequency and adolescent family satisfaction and between conflict frequency and adolescent self-satisfaction. Chinese adolescents in Grades 7, 8, 10, and 11 (N = 524) completed measures on conflict frequency, conflict coping tactics, family satisfaction, and self-satisfaction. An analysis of variance (ANOVA) and structural equation model analyses found, first, that conflict frequency decreased with grade level. For coping tactics, conciliation, avoidance, and assertion behaviors increased with grade level. Second, conflict frequency was negatively related to family satisfaction regardless of conciliation and avoidance tactics. By contrast, conflict frequency was negatively related to self-satisfaction when high conciliation and high avoidance behaviors were practiced. In addition, at low conflict frequency conciliation was positively associated with self-satisfaction and was not significant at high conflict frequency.
Wang, Jingwen; Skoog, Tiina; Einarsdottir, Elisabet; Kaartokallio, Tea; Laivuori, Hannele; Grauers, Anna; Gerdhem, Paul; Hytönen, Marjo; Lohi, Hannes; Kere, Juha; Jiao, Hong
2016-01-01
High-throughput sequencing using pooled DNA samples can facilitate genome-wide studies on rare and low-frequency variants in a large population. Some major questions concerning the pooling sequencing strategy are whether rare and low-frequency variants can be detected reliably, and whether estimated minor allele frequencies (MAFs) can represent the actual values obtained from individually genotyped samples. In this study, we evaluated MAF estimates using three variant detection tools with two sets of pooled whole exome sequencing (WES) and one set of pooled whole genome sequencing (WGS) data. Both GATK and Freebayes displayed high sensitivity, specificity and accuracy when detecting rare or low-frequency variants. For the WGS study, 56% of the low-frequency variants in Illumina array have identical MAFs and 26% have one allele difference between sequencing and individual genotyping data. The MAF estimates from WGS correlated well (r = 0.94) with those from Illumina arrays. The MAFs from the pooled WES data also showed high concordance (r = 0.88) with those from the individual genotyping data. In conclusion, the MAFs estimated from pooled DNA sequencing data reflect the MAFs in individually genotyped samples well. The pooling strategy can thus be a rapid and cost-effective approach for the initial screening in large-scale association studies. PMID:27633116
Stamoulis, Catherine; Schomer, Donald L; Chang, Bernard S
2013-08-01
How a seizure terminates is still under-studied and, despite its clinical importance, remains an obscure phase of seizure evolution. Recent studies of seizure-related scalp EEGs at frequencies >100 Hz suggest that neural activity, in the form of oscillations and/or neuronal network interactions, may play an important role in preictal/ictal seizure evolution (Andrade-Valenca et al., 2011; Stamoulis et al., 2012). However, the role of high-frequency activity in seizure termination, is unknown, if it exists at all. Using information theoretic measures of network coordination, this study investigated ictal and immediate postictal neurodynamic interactions encoded in scalp EEGs from a relatively small sample of 8 patients with focal epilepsy and multiple seizures originating in temporal and/or frontal brain regions, at frequencies ≤ 100 Hz and >100 Hz, respectively. Despite some heterogeneity in the dynamics of these interactions, consistent patterns were also estimated. Specifically, in several seizures, linear or non-linear increase in high-frequency neuronal coordination during ictal intervals, coincided with a corresponding decrease in coordination at frequencies <100 Hz, suggesting a potential interference role of high-frequency activity, to disrupt abnormal ictal synchrony at lower frequencies. These changes in network synchrony started at least 20-30s prior to seizure offset, depending on the seizure duration. Opposite patterns were estimated at frequencies ≤ 100 Hz in several seizures. These results raise the possibility that high-frequency interference may occur in the form of progressive network coordination during the ictal interval, which continues during the postictal interval. This may be one of several possible mechanisms that facilitate seizure termination. In fact, inhibition of pairwise interactions between EEGs by other signals in their spatial neighborhood, quantified by negative interaction information, was estimated at frequencies ≤ 100 Hz, at least in some seizures. Copyright © 2013 Elsevier B.V. All rights reserved.
Su, Hong-Lin; Chiang, Chien-Yi; Lu, Zong-Han; Cheng, Fu-Chou; Chen, Chun-Jung; Sheu, Meei-Ling; Sheehan, Jason; Pan, Hung-Chuan
2018-06-25
High-frequency transcutaneous neuromuscular electrical nerve stimulation (TENS) is currently used for the administration of electrical current in denervated muscle to alleviate muscle atrophy and enhance motor function; however, the time window (i.e. either immediate or delayed) for achieving benefit is still undetermined. In this study, we conducted an intervention of sciatic nerve crush injury using high-frequency TENS at different time points to assess the effect of motor and sensory functional recovery. Animals with left sciatic nerve crush injury received TENS treatment starting immediately after injury or 1 week later at a high frequency(100 Hz) or at a low frequency (2 Hz) as a control. In SFI gait analysis, either immediate or late admission of high-frequency electrical stimulation exerted significant improvement compared to either immediate or late administration of low-frequency electrical stimulation. In an assessment of allodynia, immediate high frequency electrical stimulation caused a significantly decreased pain threshold compared to late high-frequency or low-frequency stimulation at immediate or late time points. Immunohistochemistry staining and western blot analysis of S-100 and NF-200 demonstrated that both immediate and late high frequency electrical stimulation showed a similar effect; however the effect was superior to that achieved with low frequency stimulation. Immediate high frequency electrical stimulation resulted in significant expression of TNF-α and synaptophysin in the dorsal root ganglion, somatosensory cortex, and hippocampus compared to late electrical stimulation, and this trend paralleled the observed effect on somatosensory evoked potential. The CatWalk gait analysis also showed that immediate electrical stimulation led to a significantly high regularity index. In primary dorsal root ganglion cells culture, high-frequency electrical stimulation also exerted a significant increase in expression of TNF-α, synaptophysin, and NGF in accordance with the in vivo results. Immediate or late transcutaneous high-frequency electrical stimulation exhibited the potential to stimulate the motor nerve regeneration. However, immediate electrical stimulation had a predilection to develop neuropathic pain. A delay in TENS initiation appears to be a reasonable approach for nerve repair and provides the appropriate time profile for its clinical application.
Characterization of Hearing Thresholds from 500 to 16,000 Hz in Dentists: A Comparative Study
Gonçalves, Claudia Giglio de Oliveira; Santos, Luciana; Lobato, Diolen; Ribas, Angela; Lacerda, Adriana Bender Moreira; Marques, Jair
2014-01-01
Introduction High-level noise exposure in dentists' workplaces may cause damages to the auditory systems. High-frequency audiometry is an important tool in the investigation in the early diagnosis of hearing loss. Objectives To analyze the auditory thresholds at frequencies from 500 to 16,000 Hz of dentists in the city of Curitiba. Methods This historic cohort study retrospectively tested hearing thresholds from 500 to 16,000 Hz with a group of dentists from Curitiba, in the state of Paraná, Brazil. Eighty subjects participated in the study, separated into a dentist group and a control group, with the same age range and gender across groups but with no history of occupational exposure to high levels of sound pressure in the control group. Subjects were tested with conventional audiometry and high-frequency audiometry and answered a questionnaire about exposure to noise. Results Results showed that 81% of dentists did not receive any information regarding noise at university; 6 (15%) dentists had sensorineural hearing impairment; significant differences were observed between the groups only at frequencies of 500 Hz and 1,000, 6,000 and 8,000 Hz in the right ear. There was no significant difference between the groups after analysis of mean hearing thresholds of high frequencies with the average hearing thresholds in conventional frequencies; subjects who had been working as dentists for longer than 10 years had worse tonal hearing thresholds at high frequencies. Conclusions In this study, we observed that dentists are at risk for the development of sensorineural hearing loss especially after 10 years of service. PMID:25992172
Airway Humidification During High-Frequency Percussive Ventilation
2009-03-01
Airway Humidification During High-Frequency Percussive Ventilation Patrick F Allan MD, Michael J Hollingsworth CRT, Gordon C Maniere CRT, Anthony K...about the risk of inadequate humidification during high- frequency percussive ventilation (HFPV). METHODS: We studied 5 humidifiers during HFPV with a...50 L/min, and the ConchaTherm Hi-Flow with VDR nebulizer) provided carinal humidification equivalent to the comparator setup, without regard to
High Frequency Acoustic Reflection and Transmission in Ocean Sediments
2006-09-30
06-1-0766 http://www.arlut.utexas.edu LONG-TERM GOALS Development of a physical model of high-frequency acoustic interaction with the...shallow water. OBJECTIVES 1) A comparative study of acoustic sediment interaction models including visco-elastic, Biot, BICSQS, and grain...experimental measurements of the bistatic return, for the purpose of defining the best physical model of high-frequency acoustic interaction with the ocean
Periodically sheared 2D Yukawa systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovács, Anikó Zsuzsa; Hartmann, Peter; Center for Astrophysics, Space Physics and Engineering Research
2015-10-15
We present non-equilibrium molecular dynamics simulation studies on the dynamic (complex) shear viscosity of a 2D Yukawa system. We have identified a non-monotonic frequency dependence of the viscosity at high frequencies and shear rates, an energy absorption maximum (local resonance) at the Einstein frequency of the system at medium shear rates, an enhanced collective wave activity, when the excitation is near the plateau frequency of the longitudinal wave dispersion, and the emergence of significant configurational anisotropy at small frequencies and high shear rates.
Saleh, Khaldoun; Millo, Jacques; Marechal, Baptiste; Dubois, Benoît; Bakir, Ahmed; Didier, Alexandre; Lacroûte, Clément; Kersalé, Yann
2018-01-31
Optical frequency division of an ultrastable laser to the microwave frequency range by an optical frequency comb has allowed the generation of microwave signals with unprecedently high spectral purity and stability. However, the generated microwave signal will suffer from a very low power level if no external optical frequency comb repetition rate multiplication device is used. This paper reports theoretical and experimental studies on the beneficial use of the Vernier effect together with the spectral selective filtering in a double directional coupler add-drop optical fibre ring resonator to increase the comb repetition rate and generate high power microwaves. The studies are focused on two selective filtering aspects: the high rejection of undesirable optical modes of the frequency comb and the transmission of the desirable modes with the lowest possible loss. Moreover, the conservation of the frequency comb stability and linewidth at the resonator output is particularly considered. Accordingly, a fibre ring resonator is designed, fabricated, and characterized, and a technique to stabilize the resonator's resonance comb is proposed. A significant power gain is achieved for the photonically generated beat note at 10 GHz. Routes to highly improve the performances of such proof-of-concept device are also discussed.
NASA Astrophysics Data System (ADS)
Bartak, Petr; Smucler, Roman
2003-06-01
The authors have verified the efficiency and safety of laser and high-frequency gingivectomy in non-periodontal indications. Within a prospective, non-selective study, they treated and monitored 357 dental areas in 139 teeth.Out of the total number, 248 areas were treated wtih a diode laser, 980nm; 109 areas with high-frequency electrocautery. The following parameters were monitored: a) regeneration of the marginal gingiva; b) generation of iatrogenic recessions or periodontal pockets; c) bleeding from gingival sulcus during probing; d) changes in tooth vitality; e) patient's subjective evaluation. The authors identified a high degree of safety in both laser and high-frequency gingivectomy, with no significant difference between these two methods. Laser gingivectomy appears to have a wider indication range, while high-frequency gingivectomy requires lower financial expenses.
Accceleration of Fatigue Tests of Polymer Composite Materials by Using High-Frequency Loadings
NASA Astrophysics Data System (ADS)
Apinis, R.
2004-03-01
The possibility of using high-frequency loading in fatigue tests of polymer composite materials is discussed. A review of studies on the use of high-frequency loading of organic-, carbon-, and glass-fiber-reinforced plastics is presented. The results obtained are compared with those found in conventional low-frequency loadings. A rig for fatigue tests of rigid materials at loading frequencies to 500 Hz is described, and results for an LM-L1 unidirectional glass-fiber plastic in loadings with frequencies of 17 and 400 Hz are given. These results confirm that it is possible to accelerate the fatigue testing of polymer composite materials by considerably increasing the loading frequency. The necessary condition for using this method is an intense cooling of specimens to prevent them from vibration heating.
Is there a First Night Effect on Sleep Bruxism? A Sleep Laboratory Study
Hasegawa, Yoko; Lavigne, Gilles; Rompré, Pierre; Kato, Takafumi; Urade, Masahiro; Huynh, Nelly
2013-01-01
Study Objectives: Sleep bruxism (SB) is reported to vary in frequency over time. The aim of this study was to assess the first night effect on SB. Methods: A retrospective polysomnographic (PSG) analysis was performed of data from a sample of SB patients (12 females, 4 males; age range: 17-39 years) recorded in a sleep laboratory over 2 consecutive nights. Sleep parameters and jaw muscle activity variables (i.e., rhythmic masticatory muscle activity [RMMA]) for SB were quantified and compared between the 2 nights. Subjects were classified into groups according to severity of RMMA frequency, such as low frequency (2-4 episodes/h and/or < 25 bursts/h) and moderate-high frequency (≥ 4 episodes/h and ≥ 25 bursts/h). Results: Overall, no first night effects were found for most sleep variables. However, total sleep time, sleep efficiency, and stage transitions showed significant time and group interactions (repeated measures ANOVAs, p ≤ 0.05). The RMMA episode index did not differ between the 2 nights, whereas the second night showed significantly higher burst index, bruxism time index, and mean burst duration (repeated measure ANOVAs, p ≤ 0.05). Five patients of 8 in the low frequency group were classified into the moderate-high frequency group on the second night, whereas only one patient in the moderate-high frequency group moved to the low frequency group. Conclusions: The results showed no overall first night effect on severity of RMMA frequency in young and healthy patients with SB. In clinical practice, one-night sleep recording may be sufficient for moderate-high frequency SB patients. However, low RMMA frequency in the first night could be confirmed by a second night based on the patient's medical and dental history. Citation: Hasegawa Y; Lavigne G; Rompré P; Kato T; Urade M; Huynh N. Is there a first night effect on sleep bruxism? A sleep laboratory study. J Clin Sleep Med 2013;9(11):1139-1145. PMID:24235894
Gao, Shengpu; Hemar, Yacine; Lewis, Gillian D; Ashokkumar, Muthupandian
2014-11-01
The inactivation of Enterobacter aerogenes in skim milk using low-frequency (20kHz) and high-frequency (850kHz) ultrasonication was investigated. It was found that low-frequency acoustic cavitation resulted in lethal damage to E. aerogenes. The bacteria were more sensitive to ultrasound in water than in reconstituted skim milk having different protein concentrations. However, high-frequency ultrasound was not able to inactivate E. aerogenes in milk even when powers as high as 50W for 60min were used. This study also showed that high-frequency ultrasonication had no influence on the viscosity and particle size of skim milk, whereas low-frequency ultrasonication resulted in the decrease in viscosity and particle size of milk. The decrease in particle size is believed to be due to the breakup of the fat globules, and possibly to the cleavage of the κ-casein present at the surface of the casein micelles. Whey proteins were also found to be slightly affected by low-frequency ultrasound, with the amounts of α-lactalbumin and β-lactoglobulin slightly decreasing. Copyright © 2013. Published by Elsevier B.V.
A study of some features of ac and dc electric power systems for a space station
NASA Technical Reports Server (NTRS)
Hanania, J. I.
1983-01-01
This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.
Salorio-Corbetto, Marina; Baer, Thomas; Moore, Brian C. J.
2017-01-01
Abstract Objective: The objective was to assess the degradation of speech sound quality produced by frequency compression for listeners with extensive high-frequency dead regions (DRs). Design: Quality ratings were obtained using values of the starting frequency (Sf) of the frequency compression both below and above the estimated edge frequency, fe, of each DR. Thus, the value of Sf often fell below the lowest value currently used in clinical practice. Several compression ratios were used for each value of Sf. Stimuli were sentences processed via a prototype hearing aid based on Phonak Exélia Art P. Study sample: Five participants (eight ears) with extensive high-frequency DRs were tested. Results: Reductions of sound-quality produced by frequency compression were small to moderate. Ratings decreased significantly with decreasing Sf and increasing CR. The mean ratings were lowest for the lowest Sf and highest CR. Ratings varied across participants, with one participant rating frequency compression lower than no frequency compression even when Sf was above fe. Conclusions: Frequency compression degraded sound quality somewhat for this small group of participants with extensive high-frequency DRs. The degradation was greater for lower values of Sf relative to fe, and for greater values of CR. Results varied across participants. PMID:27724057
Design, Fabrication and Characterization of A Bi-Frequency Co-Linear Array
Wang, Zhuochen; Li, Sibo; Czernuszewicz, Tomasz J; Gallippi, Caterina M.; Liu, Ruibin; Geng, Xuecang
2016-01-01
Ultrasound imaging with high resolution and large penetration depth has been increasingly adopted in medical diagnosis, surgery guidance, and treatment assessment. Conventional ultrasound works at a particular frequency, with a −6 dB fractional bandwidth of ~70 %, limiting the imaging resolution or depth of field. In this paper, a bi-frequency co-linear array with resonant frequencies of 8 MHz and 20 MHz was investigated to meet the requirements of resolution and penetration depth for a broad range of ultrasound imaging applications. Specifically, a 32-element bi-frequency co-linear array was designed and fabricated, followed by element characterization and real-time sectorial scan (S-scan) phantom imaging using a Verasonics system. The bi-frequency co-linear array was tested in four different modes by switching between low and high frequencies on transmit and receive. The four modes included the following: (1) transmit low, receive low, (2) transmit low, receive high, (3) transmit high, receive low, (4) transmit high, receive high. After testing, the axial and lateral resolutions of all modes were calculated and compared. The results of this study suggest that bi-frequency co-linear arrays are potential aids for wideband fundamental imaging and harmonic/sub-harmonic imaging. PMID:26661069
Data mining neocortical high-frequency oscillations in epilepsy and controls
Stead, Matt; Krieger, Abba; Stacey, William; Maus, Douglas; Marsh, Eric; Viventi, Jonathan; Lee, Kendall H.; Marsh, Richard; Litt, Brian; Worrell, Gregory A.
2011-01-01
Transient high-frequency (100–500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100–250 Hz) and fast ripple (250–500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100–500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value. PMID:21903727
Data mining neocortical high-frequency oscillations in epilepsy and controls.
Blanco, Justin A; Stead, Matt; Krieger, Abba; Stacey, William; Maus, Douglas; Marsh, Eric; Viventi, Jonathan; Lee, Kendall H; Marsh, Richard; Litt, Brian; Worrell, Gregory A
2011-10-01
Transient high-frequency (100-500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100-250 Hz) and fast ripple (250-500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100-500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value.
ERIC Educational Resources Information Center
Grover, Lawrence M.; Kim, Eunyoung; Cooke, Jennifer D.; Holmes, William R.
2009-01-01
Long-term potentiation (LTP) is typically studied using either continuous high-frequency stimulation or theta burst stimulation. Previous studies emphasized the physiological relevance of theta frequency; however, synchronized hippocampal activity occurs over a broader frequency range. We therefore tested burst stimulation at intervals from 100…
Continuous high-frequency activity in mesial temporal lobe structures
Mari, Francesco; Zelmann, Rina; Andrade-Valenca, Luciana; Dubeau, Francois; Gotman, Jean
2013-01-01
Summary Purpose Many recent studies have reported the importance of high-frequency oscillations (HFOs) in the intracerebral electroencephalography (EEG) of patients with epilepsy. These HFOs have been defined as events that stand out from the background. We have noticed that this background often consists itself of high-frequency rhythmic activity. The purpose of this study is to perform a first evaluation of the characteristics of high-frequency continuous or semicontinuous background activity. Methods Because the continuous high-frequency pattern was noted mainly in mesial temporal structures, we reviewed the EEG studies from these structures in 24 unselected patients with electrodes implanted in these regions. Sections of background away from interictal spikes were marked visually during periods of slow-wave sleep and wakefulness. They were then high-passed filtered at 80 Hz and categorized as having high-frequency rhythmic activity in one of three patterns: continuous/semicontinuous, irregular, sporadic. Wavelet entropy, which measures the degree of rhythmicity of a signal, was calculated for the marked background sections. Key Findings Ninety-six bipolar channels were analyzed. The continuous/semicontinuous pattern was found frequently (29/96 channels during wake and 34/96 during sleep). The different patterns were consistent between sleep and wakefulness. The continuous/semicontinuous pattern was found significantly more often in the hippocampus than in the parahippocampal gyrus and was rarely found in the amygdala. The types of pattern were not influenced by whether a channel was within the seizure-onset zone, or whether it was a lesional channel. The continuous/semicontinuous pattern was associated with a higher frequency of spikes and with high rates of ripples and fast ripples. Significance It appears that high-frequency activity (above 80 Hz) does not appear only in the form of brief paroxysmal events but also in the form of continuous rhythmic activity or very long bursts. In this study limited to mesial temporal structures, we found a clear anatomic preference for the hippocampus. Although associated with spikes and with distinct HFOs, this pattern was not clearly associated with the seizure-onset zone. Future studies will need to evaluate systematically the presence of this pattern, as it may have a pathophysiologic significance and it will also have an important influence on the very definition of HFOs. PMID:22416973
Age-related macular degeneration changes the processing of visual scenes in the brain.
Ramanoël, Stephen; Chokron, Sylvie; Hera, Ruxandra; Kauffmann, Louise; Chiquet, Christophe; Krainik, Alexandre; Peyrin, Carole
2018-01-01
In age-related macular degeneration (AMD), the processing of fine details in a visual scene, based on a high spatial frequency processing, is impaired, while the processing of global shapes, based on a low spatial frequency processing, is relatively well preserved. The present fMRI study aimed to investigate the residual abilities and functional brain changes of spatial frequency processing in visual scenes in AMD patients. AMD patients and normally sighted elderly participants performed a categorization task using large black and white photographs of scenes (indoors vs. outdoors) filtered in low and high spatial frequencies, and nonfiltered. The study also explored the effect of luminance contrast on the processing of high spatial frequencies. The contrast across scenes was either unmodified or equalized using a root-mean-square contrast normalization in order to increase contrast in high-pass filtered scenes. Performance was lower for high-pass filtered scenes than for low-pass and nonfiltered scenes, for both AMD patients and controls. The deficit for processing high spatial frequencies was more pronounced in AMD patients than in controls and was associated with lower activity for patients than controls not only in the occipital areas dedicated to central and peripheral visual fields but also in a distant cerebral region specialized for scene perception, the parahippocampal place area. Increasing the contrast improved the processing of high spatial frequency content and spurred activation of the occipital cortex for AMD patients. These findings may lead to new perspectives for rehabilitation procedures for AMD patients.
In Vivo, High-Frequency Three-Dimensional Cardiac MR Elastography: Feasibility in Normal Volunteers
Arani, Arvin; Glaser, Kevin L.; Arunachalam, Shivaram P.; Rossman, Phillip J.; Lake, David S.; Trzasko, Joshua D.; Manduca, Armando; McGee, Kiaran P.; Ehman, Richard L.; Araoz, Philip A.
2016-01-01
Purpose Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. Methods The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). Results The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. Conclusion This study motivates future evaluation of high-frequency 3D MRE in patient populations. PMID:26778442
Extrinsic and Intrinsic Frequency Dispersion of High-k Materials in Capacitance-Voltage Measurements
Tao, J.; Zhao, C.Z.; Zhao, C.; Taechakumput, P.; Werner, M.; Taylor, S.; Chalker, P. R.
2012-01-01
In capacitance-voltage (C-V) measurements, frequency dispersion in high-k dielectrics is often observed. The frequency dependence of the dielectric constant (k-value), that is the intrinsic frequency dispersion, could not be assessed before suppressing the effects of extrinsic frequency dispersion, such as the effects of the lossy interfacial layer (between the high-k thin film and silicon substrate) and the parasitic effects. The effect of the lossy interfacial layer on frequency dispersion was investigated and modeled based on a dual frequency technique. The significance of parasitic effects (including series resistance and the back metal contact of the metal-oxide-semiconductor (MOS) capacitor) on frequency dispersion was also studied. The effect of surface roughness on frequency dispersion is also discussed. After taking extrinsic frequency dispersion into account, the relaxation behavior can be modeled using the Curie-von Schweidler (CS) law, the Kohlrausch-Williams-Watts (KWW) relationship and the Havriliak-Negami (HN) relationship. Dielectric relaxation mechanisms are also discussed. PMID:28817021
The relationship between journal use in a medical library and citation use.
Tsay, M Y
1998-01-01
The purpose of the study was to investigate the relationship between library journal use and journal citation use in the medical sciences. The six-month journal use study was conducted in the Library of the Veterans General Hospital in Taipei. The data on citation frequency and impact factors were obtained from Journal Citation Reports, 1993 microfiche edition. The study explored the use, citation, and impact factor data, especially for heavily used, highly cited, or high-impact-factor journals. The correlations between frequency of use and citation frequency and between frequency of use and impact factor were determined by using the Spearman rank and Pearson correlation tests. The same comparisons were also made within four subject categories: clinical medicine journals, life science journals, hybrid journals publishing both clinical medicine and life science papers, and journals that publish neither clinical medicine nor life science articles. The results of the study showed that there is a significant correlation between frequency of use and citation frequency, and between frequency of use and impact factor for all titles. There is also a significant correlation between frequency of use and citation frequency and between frequency of use and impact factor for journals that publish either clinical medicine or life science articles, or both. However, the correlation is not significant for other journals. PMID:9549010
NASA Astrophysics Data System (ADS)
Kiuchi, R.; Mori, J. J.
2015-12-01
As a way to understand the characteristics of the earthquake source, studies of source parameters (such as radiated energy and stress drop) and their scaling are important. In order to estimate source parameters reliably, often we must use appropriate source spectrum models and the omega-square model is most frequently used. In this model, the spectrum is flat in lower frequencies and the falloff is proportional to the angular frequency squared. However, Some studies (e.g. Allmann and Shearer, 2009; Yagi et al., 2012) reported that the exponent of the high frequency falloff is other than -2. Therefore, in this study we estimate the source parameters using a spectral model for which the falloff exponent is not fixed. We analyze the mainshock and larger aftershocks of the 2008 Iwate-Miyagi Nairiku earthquake. Firstly, we calculate the P wave and SH wave spectra using empirical Green functions (EGF) to remove the path effect (such as attenuation) and site effect. For the EGF event, we select a smaller earthquake that is highly-correlated with the target event. In order to obtain the stable results, we calculate the spectral ratios using a multitaper spectrum analysis (Prieto et al., 2009). Then we take a geometric mean from multiple stations. Finally, using the obtained spectra ratios, we perform a grid search to determine the high frequency falloffs, as well as corner frequency of both of events. Our results indicate the high frequency falloff exponent is often less than 2.0. We do not observe any regional, focal mechanism, or depth dependencies for the falloff exponent. In addition, our estimated corner frequencies and falloff exponents are consistent between the P wave and SH wave analysis. In our presentation, we show differences in estimated source parameters using a fixed omega-square model and a model allowing variable high-frequency falloff.
Nonlinear frequency compression: effects on sound quality ratings of speech and music.
Parsa, Vijay; Scollie, Susan; Glista, Danielle; Seelisch, Andreas
2013-03-01
Frequency lowering technologies offer an alternative amplification solution for severe to profound high frequency hearing losses. While frequency lowering technologies may improve audibility of high frequency sounds, the very nature of this processing can affect the perceived sound quality. This article reports the results from two studies that investigated the impact of a nonlinear frequency compression (NFC) algorithm on perceived sound quality. In the first study, the cutoff frequency and compression ratio parameters of the NFC algorithm were varied, and their effect on the speech quality was measured subjectively with 12 normal hearing adults, 12 normal hearing children, 13 hearing impaired adults, and 9 hearing impaired children. In the second study, 12 normal hearing and 8 hearing impaired adult listeners rated the quality of speech in quiet, speech in noise, and music after processing with a different set of NFC parameters. Results showed that the cutoff frequency parameter had more impact on sound quality ratings than the compression ratio, and that the hearing impaired adults were more tolerant to increased frequency compression than normal hearing adults. No statistically significant differences were found in the sound quality ratings of speech-in-noise and music stimuli processed through various NFC settings by hearing impaired listeners. These findings suggest that there may be an acceptable range of NFC settings for hearing impaired individuals where sound quality is not adversely affected. These results may assist an Audiologist in clinical NFC hearing aid fittings for achieving a balance between high frequency audibility and sound quality.
Kong, Lingyue; Zhang, John X; Zhang, Yongwei
2016-08-01
The present study used an online grammaticality judgment task to examine whether Chinese discontinuous correlative conjunctions are psychologically real in mental lexicon. High- and low-frequency discontinuous correlative conjunctions were compared with random combinations differing in combination frequencies but matched for constituent word frequency. Forty graduate students participated in the study. Results showed that responses were faster and more accurate for high-frequency correlative conjunctions than low-frequency ones, but the effects were absent for random combinations. The results indicate that Chinese discontinuous correlative conjunctions have psychological reality in mental lexicon in addition to the representation of their constituent words, and that grammatical functions of correlative conjunctions may be a critical factor for the formation of such holistic representations. © The Author(s) 2016.
Spectral decomposition of internal gravity wave sea surface height in global models
NASA Astrophysics Data System (ADS)
Savage, Anna C.; Arbic, Brian K.; Alford, Matthew H.; Ansong, Joseph K.; Farrar, J. Thomas; Menemenlis, Dimitris; O'Rourke, Amanda K.; Richman, James G.; Shriver, Jay F.; Voet, Gunnar; Wallcraft, Alan J.; Zamudio, Luis
2017-10-01
Two global ocean models ranging in horizontal resolution from 1/12° to 1/48° are used to study the space and time scales of sea surface height (SSH) signals associated with internal gravity waves (IGWs). Frequency-horizontal wavenumber SSH spectral densities are computed over seven regions of the world ocean from two simulations of the HYbrid Coordinate Ocean Model (HYCOM) and three simulations of the Massachusetts Institute of Technology general circulation model (MITgcm). High wavenumber, high-frequency SSH variance follows the predicted IGW linear dispersion curves. The realism of high-frequency motions (>0.87 cpd) in the models is tested through comparison of the frequency spectral density of dynamic height variance computed from the highest-resolution runs of each model (1/25° HYCOM and 1/48° MITgcm) with dynamic height variance frequency spectral density computed from nine in situ profiling instruments. These high-frequency motions are of particular interest because of their contributions to the small-scale SSH variability that will be observed on a global scale in the upcoming Surface Water and Ocean Topography (SWOT) satellite altimetry mission. The variance at supertidal frequencies can be comparable to the tidal and low-frequency variance for high wavenumbers (length scales smaller than ˜50 km), especially in the higher-resolution simulations. In the highest-resolution simulations, the high-frequency variance can be greater than the low-frequency variance at these scales.
Alcohol Effects on Simulated Driving in Frequent and Infrequent Binge Drinkers
Bernosky-Smith, Kimberly A.; Shannon, Erin E.; Roth, Alicia J.; Liguori, Anthony
2011-01-01
Objective Compared to non-bingers, binge drinkers are more likely to drive while intoxicated. The extent to which binge frequency impacts confidence in driving and subsequent driving impairment is unknown. This study compared the effects of an experimenter-delivered alcohol binge on subjective impairment and simulated driving ability in female High and Low Frequency bingers. Methods Female drinkers were assigned to High Frequency (n=30) or Low Frequency (n=30) binge groups based on their Alcohol Use Questionnaire responses. At 30-minute intervals within a two-hour period, participants received either a placebo drink (n=15 per group) or a 0.2 g/kg dose of alcohol (n=15 per group; cumulative dose 0.8 g/kg). Self-reported impairment, driving confidence, and simulated driving were then measured. Results Self-reported confidence in driving was significantly lower after alcohol than after placebo in Low Frequency but not High Frequency bingers. Self-reported impairment and collisions during simulated driving were significantly greater after alcohol than after placebo in both Low Frequency and High Frequency bingers. Conclusions The impairing effects of a single alcohol binge on driving ability in females are not influenced by binge frequency. However, high binge frequency may be associated with a less cautious approach to post-binge driving. PMID:21542027
Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A
2009-01-01
An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.
a Study of a High Frequency Miniature Reservoir-Less Pulse Tube
NASA Astrophysics Data System (ADS)
Garaway, I.; Grossman, G.
2008-03-01
A miniature high frequency reservoir-less pulse tube cryocooler has been designed and tested in our laboratory. The cryocooler having a regenerator length of 12.0 mm and an overall volume of 2.3cc (excluding the compressor) reached a low temperature of 146K and provided 100mW of cooling at 160K. This experimental study shows that it is possible to miniaturize a pulse tube cryocooler to very short regenerator lengths by implementing a few basic principles: Most importantly, high operating frequencies at small tidal displacements, a regenerator matrix with small hydraulic diameters, and increased helium fill pressures. This study also shows that as the operating frequency of a miniature cryocooler increases, the reservoir becomes less necessary as a phase shifting device. At higher frequencies and appropriate inertance tube geometries, the impedance and capacitance of the inertance tube itself takes over the phase shifting task. An outline of the design and modeling principles is presented along with some details of the experimental apparatus and testing procedures.
High-energy sources at low radio frequency: the Murchison Widefield Array view of Fermi blazars
Giroletti, M.; Massaro, F.; D’Abrusco, R.; ...
2016-04-01
Low-frequency radio arrays are opening a new window for the study of the sky, both to study new phenomena and to better characterize known source classes. Being flat-spectrum sources, blazars are so far poorly studied at low radio frequencies. In this paper, we characterize the spectral properties of the blazar population at low radio frequency, compare the radio and high-energy properties of the gamma-ray blazar population, and search for radio counterparts of unidentified gamma-ray sources. We cross-correlated the 6100 deg 2 Murchison Widefield Array Commissioning Survey catalogue with the Roma blazar catalogue, the third catalogue of active galactic nuclei detectedmore » by Fermi-LAT, and the unidentified members of the entire third catalogue of gamma-ray sources detected by Fermi-LAT. When available, we also added high-frequency radio data from the Australia Telescope 20 GHz catalogue. We find low-frequency counterparts for 186 out of 517 (36%) blazars, 79 out of 174 (45%) gamma-ray blazars, and 8 out of 73 (11%) gamma-ray blazar candidates. The mean low-frequency (120–180 MHz) blazar spectral index is (α low) = 0.57 ± 0.02: blazar spectra are flatter than the rest of the population of low-frequency sources, but are steeper than at ~GHz frequencies. Low-frequency radio flux density and gamma-ray energy flux display a mildly significant and broadly scattered correlation. Ten unidentified gamma-ray sources have a (probably fortuitous) positional match with low radio frequency sources. Low-frequency radio astronomy provides important information about sources with a flat radio spectrum and high energy. However, the relatively low sensitivity of the present surveys still misses a significant fraction of these objects. Finally, upcoming deeper surveys, such as the GaLactic and Extragalactic All-Sky MWA (GLEAM) survey, will provide further insight into this population.« less
High-energy sources at low radio frequency: the Murchison Widefield Array view of Fermi blazars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giroletti, M.; Massaro, F.; D’Abrusco, R.
Low-frequency radio arrays are opening a new window for the study of the sky, both to study new phenomena and to better characterize known source classes. Being flat-spectrum sources, blazars are so far poorly studied at low radio frequencies. In this paper, we characterize the spectral properties of the blazar population at low radio frequency, compare the radio and high-energy properties of the gamma-ray blazar population, and search for radio counterparts of unidentified gamma-ray sources. We cross-correlated the 6100 deg 2 Murchison Widefield Array Commissioning Survey catalogue with the Roma blazar catalogue, the third catalogue of active galactic nuclei detectedmore » by Fermi-LAT, and the unidentified members of the entire third catalogue of gamma-ray sources detected by Fermi-LAT. When available, we also added high-frequency radio data from the Australia Telescope 20 GHz catalogue. We find low-frequency counterparts for 186 out of 517 (36%) blazars, 79 out of 174 (45%) gamma-ray blazars, and 8 out of 73 (11%) gamma-ray blazar candidates. The mean low-frequency (120–180 MHz) blazar spectral index is (α low) = 0.57 ± 0.02: blazar spectra are flatter than the rest of the population of low-frequency sources, but are steeper than at ~GHz frequencies. Low-frequency radio flux density and gamma-ray energy flux display a mildly significant and broadly scattered correlation. Ten unidentified gamma-ray sources have a (probably fortuitous) positional match with low radio frequency sources. Low-frequency radio astronomy provides important information about sources with a flat radio spectrum and high energy. However, the relatively low sensitivity of the present surveys still misses a significant fraction of these objects. Finally, upcoming deeper surveys, such as the GaLactic and Extragalactic All-Sky MWA (GLEAM) survey, will provide further insight into this population.« less
Edge-Oriented Graphene on Carbon Nanofiber for High-Frequency Supercapacitors
NASA Astrophysics Data System (ADS)
Islam, Nazifah; Warzywoda, Juliusz; Fan, Zhaoyang
2018-03-01
High-frequency supercapacitors are being studied with the aim to replace the bulky electrolytic capacitors for current ripple filtering and other functions used in power systems. Here, 3D edge-oriented graphene (EOG) was grown encircling carbon nanofiber (CNF) framework to form a highly conductive electrode with a large surface area. Such EOG/CNF electrodes were tested in aqueous and organic electrolytes for high-frequency supercapacitor development. For the aqueous and the organic cell, the characteristic frequency at - 45° phase angle was found to be as high as 22 and 8.5 kHz, respectively. At 120 Hz, the electrode capacitance density was 0.37 and 0.16 mF cm-2 for the two cells. In particular, the 3 V high-frequency organic cell was successfully tested as filtering capacitor used in AC/DC converter, suggesting the promising potential of this technology for compact power supply design and other applications. [Figure not available: see fulltext.
Ma, Teng; Zhang, Xiangyang; Chiu, Chi Tat; Chen, Ruimin; Kirk Shung, K.; Zhou, Qifa; Jiao, Shuliang
2014-01-01
Abstract. Photoacoustic ophthalmoscopy (PAOM) is a high-resolution in vivo imaging modality that is capable of providing specific optical absorption information for the retina. A high-frequency ultrasonic transducer is one of the key components in PAOM, which is in contact with the eyelid through coupling gel during imaging. The ultrasonic transducer plays a crucial role in determining the image quality affected by parameters such as spatial resolution, signal-to-noise ratio, and field of view. In this paper, we present the results of a systematic study on a high-frequency ultrasonic transducer design for PAOM. The design includes piezoelectric material selection, frequency selection, and the fabrication process. Transducers of various designs were successfully applied for capturing images of biological samples in vivo. The performances of these designs are compared and evaluated. PMID:24441942
Ma, Teng; Zhang, Xiangyang; Chiu, Chi Tat; Chen, Ruimin; Kirk Shung, K; Zhou, Qifa; Jiao, Shuliang
2014-01-01
Photoacoustic ophthalmoscopy (PAOM) is a high-resolution in vivo imaging modality that is capable of providing specific optical absorption information for the retina. A high-frequency ultrasonic transducer is one of the key components in PAOM, which is in contact with the eyelid through coupling gel during imaging. The ultrasonic transducer plays a crucial role in determining the image quality affected by parameters such as spatial resolution, signal-to-noise ratio, and field of view. In this paper, we present the results of a systematic study on a high-frequency ultrasonic transducer design for PAOM. The design includes piezoelectric material selection, frequency selection, and the fabrication process. Transducers of various designs were successfully applied for capturing images of biological samples in vivo. The performances of these designs are compared and evaluated.
[A Feasibility Study of closing the small bowel with high-frequency welding device].
Zhou, Huabin; Han, Shuai; Chen, Jun; Huang, Dequn; Peng, Liang; Ning, Jingxuan; Li, Zhou
2014-12-01
This study aimed to evaluate the feasibility and effectiveness of closing the small bowel in an ex vivo porcine model with high-frequency welding device. A total of 100 porcine small bowels were divided into two groups, and then were closed with two different methods. The fifty small bowels in experimental group were closed by the high-frequency welding device, and the other fifty small bowels in comparison group were hand-sutured. All the small bowels were subjected to leak pressure testing later on. The speed of closure and bursting pressure were compared. The 50 porcine small bowels closed by the high-frequency welding device showed a success rate of 100%. Compared with the hand-sutured group, the bursting pressures of the former were significantly lower (P<0.01) and the closing process was significantly shorter (P<0.01). The pathological changes of the closed ends mainly presented as acute thermal and pressure induced injury. Experimental results show that the high-frequency welding device has higher feasibility in closing the small bowel.
[Objective study of the voice quality following partial laryngectomy].
Remacle, M; Millet, B
1991-01-01
The high resolution frequency analyzer is used for the study of the vocal quality after partial laryngectomy. The post-operative plot after speech therapy is of good quality when respecting one vocal fold. On the contrary, the heard vocal sound does not correspond to the harmonics of the fundamental frequency but to intense noise from irregular vibrations of the residual laryngeal mucosa (ventricular folds, arytenoids). High resolution frequency analysis contributes to the follow-up of the partial laryngectomy.
Study on sound-speed dispersion in a sandy sediment at frequency ranges of 0.5-3 kHz and 90-170 kHz
NASA Astrophysics Data System (ADS)
Yu, Sheng-qi; Liu, Bao-hua; Yu, Kai-ben; Kan, Guang-ming; Yang, Zhi-guo
2017-03-01
In order to study the properties of sound-speed dispersion in a sandy sediment, the sound speed was measured both at high frequency (90-170 kHz) and low frequency (0.5-3 kHz) in laboratory environments. At high frequency, a sampling measurement was conducted with boiled and uncooked sand samples collected from the bottom of a large water tank. The sound speed was directly obtained through transmission measurement using single source and single hydrophone. At low frequency, an in situ measurement was conducted in the water tank, where the sandy sediment had been homogeneously paved at the bottom for a long time. The sound speed was indirectly inverted according to the traveling time of signals received by three buried hydrophones in the sandy sediment and the geometry in experiment. The results show that the mean sound speed is approximate 1710-1713 m/s with a weak positive gradient in the sand sample after being boiled (as a method to eliminate bubbles as much as possible) at high frequency, which agrees well with the predictions of Biot theory, the effective density fluid model (EDFM) and Buckingham's theory. However, the sound speed in the uncooked sandy sediment obviously decreases (about 80%) both at high frequency and low frequency due to plenty of bubbles in existence. And the sound-speed dispersion performs a weak negative gradient at high frequency. Finally, a water-unsaturated Biot model is presented for trying to explain the decrease of sound speed in the sandy sediment with plenty of bubbles.
NASA Astrophysics Data System (ADS)
Liu, Xiaofei; Zhang, Qiuwen
2016-11-01
Studies have considered the many factors involved in the mechanism of reservoir seismicity. Focusing on the correlation between reservoir-induced seismicity and the water level, this study proposes to utilize copula theory to build a correlation model to analyze their relationships and perform the risk analysis. The sequences of reservoir induced seismicity events from 2003 to 2011 in the Three Gorges reservoir in China are used as a case study to test this new methodology. Next, we construct four correlation models based on the Gumbel, Clayton, Frank copula and M-copula functions and employ four methods to test the goodness of fit: Q-Q plots, the Kolmogorov-Smirnov (K-S) test, the minimum distance (MD) test and the Akaike Information Criterion (AIC) test. Through a comparison of the four models, the M-copula model fits the sample better than the other three models. Based on the M-copula model, we find that, for the case of a sudden drawdown of the water level, the possibility of seismic frequency decreasing obviously increases, whereas for the case of a sudden rising of the water level, the possibility of seismic frequency increasing obviously increases, with the former being greater than the latter. The seismic frequency is mainly distributed in the low-frequency region (Y ⩽ 20) for the low water level and in the middle-frequency region (20 < Y ≤ 80) for both the medium and high water levels; the seismic frequency in the high-frequency region (Y > 80) is the least likely. For the conditional return period, it can be seen that the period of the high-frequency seismicity is much longer than those of the normal and medium frequency seismicity, and the high water level shortens the periods.
Xue, L J; Yang, A C; Chen, H; Huang, W X; Guo, J J; Liang, X Y; Chen, Z Q; Zheng, Q L
2017-11-20
Objective: Study of the results and the degree on occupational noise-induced deafness in-to the different high frequency hearing threshold weighted value, in order to provide theoretical basis for the re-vision of diagnostic criteria on occupational noise-induced deafness. Methods: A retrospective study was con-ducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. Based on the re-sults of the 3 hearing test for each test interval greater than 3 days in the hospital, the best threshold of each frequency was obtained, and based on the diagnostic criteria of occupational noise deafness in 2007 edition, Chi square test, t test and variance analysis were used to measure SPSS21.0 data, their differences are tested among the means of speech frequency and the high frequency weighted value into different age group, noise ex-posure group, and diagnostic classification between different dimensions. Results: 1. There were totally 168 cases in accordance with the study plan, male 154 cases, female 14 cases, the average age was 41.18 ±6.07 years old. 2. The diagnosis rate was increased into the weighted value of different high frequency than the mean value of pure speech frequency, the weighted 4 kHz frequency increased by 13.69% (χ(2)=9.880, P =0.002) , 6 kHz increased by 15.47% (χ(2)=9.985, P =0.002) and 4 kHz+6 kHz increased by15.47% (χ(2)=9.985, P =0.002) , the difference was statistically significant. The diagnostic rate of different high threshold had no obvious differ-ence between the genders. 3. The age groups were divided into less than or equal to 40years old group (A group) and 40-50 years old group (group B) , there were higher the diagnostic rate between high frequency weighted 4 kHz (A group χ(2)=3.380, P =0.050; B group χ(2)=4.054, P =0.032) , weighted 6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) , high frequency weighted 4 kHz+6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) than those of speech frequency average value in the same group on oc-cupational noise-induced deafness diagnosis rate, the difference was statistically significant. There was no sig-nificant difference between age groups (χ(2)=2.265, P =0.944) . 4. The better ear's mean value of pure speech fre-quency and the weighted values into different high frequency of working years on each group were compared, working years more than 10 years group was significantly higher than that of average thresholds of each frequen-cy band in 3-5 group ( F =2.271, P =0.001) , 6-10 group ( F =1.563, P =0.046) , the difference was statistically significant. The different high frequency weighted values were higher than those of the mean value of pure speech frequency, and the high frequency weighted 4 kHz+6 kHz had the highest frequency difference, with an average increase of 2.83 dB. 5. The diagnostic rate into weighted different high frequency was higher in the mild, moderate and severe grades than in the pure speech frequency. In the comparison of diagnosis for mild occupational noise-induced deafness, in addition to the weighted 3 kHz high frequency (χ(2)=3.117, P =0.077) had no significant difference, the weighted 4 kHz (χ(2)=10.835, P =0.001) , 6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz (χ(2)=6.315, P =0.012) , 3 kHz+6 kHz (χ(2)=6.315, P =0.012) , 4 kHz+6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz+6 kHz (χ(2)=7.667, P =0.002) were significantly higher than the diagnosis rate of the mean value of pure speech frequency. There was no significant difference between the two groups in the moderate and se-vere grades ( P >0.05) . Conclusion: Bring into different high frequency hearing threshold weighted value in-creases the diagnostic rate of occupational noise-induced deafness, the weighted 4 kHz, 6 kHz and 4 kHz+ 6 kHz high frequency value affects the result greatly, and the weighted 4 kHz+6 kHz high frequency hearing threshold value is maximum the effect on occupational noise-induced deafness diagnosis.
A study on the prenatal zone of ultrasonic guided waves in plates
NASA Astrophysics Data System (ADS)
Thomas, Tibin; Balasubramaniam, Krishnan
2017-02-01
Low frequency guided wave based inspection is an extensively used method for asset management with the advantage of wide area coverage from a single location at the cost of spatial resolution. With the advent of high frequency guided waves, short range inspections with high spatial resolution for monitoring corrosion under pipe supports and tank annular plates has gained widespread interest and acceptance. One of the major challenges in the application of high frequency guided waves in a short range inspection is to attain the desired modal displacements with respect to the application. In this paper, an investigation on the generation and formation of fundamental S0 mode is carried out through numerical simulation and experiments to establish a prenatal zone for guided waves. The effect of frequency, thickness of the plate and frequency-thickness (f*d) is studied. The investigation reveals the existence of a rudimentary form with similar modal features to the fully developed mode. This study helps in the design and development of a high frequency guided wave generator for particular applications which demands waves with very less sensitivity to the surface and loading during the initial phase which immediately evolves to a more sensitive wave towards the surface on propagation for the detection of shallow defects.
Investigation of spectral analysis techniques for randomly sampled velocimetry data
NASA Technical Reports Server (NTRS)
Sree, Dave
1993-01-01
It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.
ERIC Educational Resources Information Center
Schubert, T. F., Jr.; Kim, E. M.
2009-01-01
The use of Miller's Theorem in the determination of the high-frequency cutoff frequency of transistor amplifiers was recently challenged by a paper published in this TRANSACTIONS. Unfortunately, that paper provided no simulation or experimental results to bring credence to the challenge or to validate the alternate method of determination…
Curing the Epilepsies: The Promise of Research
... Using microelectrodes, researchers are able to better characterize high-frequency oscillations (HFOs). Abnormal HFOs have been linked to ... Using microelectrodes, researchers are able to better characterize high-frequency oscillations. Top Develop New Animal Models for Studying ...
NASA Astrophysics Data System (ADS)
Schönborn, Jan Boyke; Saalfrank, Peter; Klamroth, Tillmann
2016-01-01
We combine the stochastic pulse optimization (SPO) scheme with the time-dependent configuration interaction singles method in order to control the high frequency response of a simple molecular model system to a tailored femtosecond laser pulse. For this purpose, we use H2 treated in the fixed nuclei approximation. The SPO scheme, as similar genetic algorithms, is especially suited to control highly non-linear processes, which we consider here in the context of high harmonic generation. Here, we will demonstrate that SPO can be used to realize a "non-harmonic" response of H2 to a laser pulse. Specifically, we will show how adding low intensity side frequencies to the dominant carrier frequency of the laser pulse and stochastically optimizing their contribution can create a high-frequency spectral signal of significant intensity, not harmonic to the carrier frequency. At the same time, it is possible to suppress the harmonic signals in the same spectral region, although the carrier frequency is kept dominant during the optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schönborn, Jan Boyke; Saalfrank, Peter; Klamroth, Tillmann, E-mail: klamroth@uni-potsdam.de
2016-01-28
We combine the stochastic pulse optimization (SPO) scheme with the time-dependent configuration interaction singles method in order to control the high frequency response of a simple molecular model system to a tailored femtosecond laser pulse. For this purpose, we use H{sub 2} treated in the fixed nuclei approximation. The SPO scheme, as similar genetic algorithms, is especially suited to control highly non-linear processes, which we consider here in the context of high harmonic generation. Here, we will demonstrate that SPO can be used to realize a “non-harmonic” response of H{sub 2} to a laser pulse. Specifically, we will show howmore » adding low intensity side frequencies to the dominant carrier frequency of the laser pulse and stochastically optimizing their contribution can create a high-frequency spectral signal of significant intensity, not harmonic to the carrier frequency. At the same time, it is possible to suppress the harmonic signals in the same spectral region, although the carrier frequency is kept dominant during the optimization.« less
Mid- to high-frequency noise from high-speed boats and its potential impacts on humpback dolphins.
Li, Songhai; Wu, Haiping; Xu, Youhou; Peng, Chongwei; Fang, Liang; Lin, Mingli; Xing, Luru; Zhang, Peijun
2015-08-01
The impact of noise made by vessels on marine animals has come under increased concern. However, most measurements on noise from vessels have only taken into account the low-frequency components. For cetaceans operating in the mid- and high-frequencies, such as the Indo-Pacific humpback dolphin (Sousa chinensis), mid- to high-frequency noise components may be of more concern, in terms of their potential impacts. In this study, noise made by a small high-speed boat was recorded using a broadband recording system in a dolphin watching area focusing on the effects on humpback dolphins in Sanniang Bay, China. The high-speed boat produced substantial mid- to high-frequency noise components with frequencies to >100 kHz, measured at three speeds: ∼40, 30, and 15 km/h. The noise from the boat raised the ambient noise levels from ∼5 to 47 decibels (dB) root-mean-square (rms) across frequency bands ranging from 1 to 125 kHz at a distance of 20 to 85 m, with louder levels recorded at higher speeds and at closer distances. To conclude, the noise produced by the small high-speed boat could be heard by Sousa chinensis and therefore potentially had adverse effects on the dolphins.
Frequency of Testing for Dyslipidemia: An Evidence-Based Analysis
2014-01-01
Background Dyslipidemias include high levels of total cholesterol, low-density lipoprotein (LDL) cholesterol, and triglycerides and low levels of high-density lipoprotein (HDL) cholesterol. Dyslipidemia is a risk factor for cardiovascular disease, which is a major contributor to mortality in Canada. Approximately 23% of the 2009/11 Canadian Health Measures Survey (CHMS) participants had a high level of LDL cholesterol, with prevalence increasing with age, and approximately 15% had a total cholesterol to HDL ratio above the threshold. Objectives To evaluate the frequency of lipid testing in adults not diagnosed with dyslipidemia and in adults on treatment for dyslipidemia. Research Methods A systematic review of the literature set out to identify randomized controlled trials (RCTs), systematic reviews, health technology assessments (HTAs), and observational studies published between January 1, 2000, and November 29, 2012, that evaluated the frequency of testing for dyslipidemia in the 2 populations. Results Two observational studies assessed the frequency of lipid testing, 1 in individuals not on lipid-lowering medications and 1 in treated individuals. Both studies were based on previously collected data intended for a different objective and, therefore, no conclusions could be reached about the frequency of testing at intervals other than the ones used in the original studies. Given this limitation and generalizability issues, the quality of evidence was considered very low. No evidence for the frequency of lipid testing was identified in the 2 HTAs included. Canadian and international guidelines recommend testing for dyslipidemia in individuals at an increased risk for cardiovascular disease. The frequency of testing recommended is based on expert consensus. Conclusions Conclusions on the frequency of lipid testing could not be made based on the 2 observational studies. Current guidelines recommend lipid testing in adults with increased cardiovascular risk, with the frequency of testing based on individual cardiovascular risk. PMID:26316920
Parkinsonian Rest Tremor Is Associated With Modulations of Subthalamic High-Frequency Oscillations.
Hirschmann, Jan; Butz, Markus; Hartmann, Christian J; Hoogenboom, Nienke; Özkurt, Tolga E; Vesper, Jan; Wojtecki, Lars; Schnitzler, Alfons
2016-10-01
High frequency oscillations (>200 Hz) have been observed in the basal ganglia of PD patients and were shown to be modulated by the administration of levodopa and voluntary movement. The objective of this study was to test whether the power of high-frequency oscillations in the STN is associated with spontaneous manifestation of parkinsonian rest tremor. The electromyogram of both forearms and local field potentials from the STN were recorded in 11 PD patients (10 men, age 58 [9.4] years, disease duration 9.2 [6.3] years). Patients were recorded at rest and while performing repetitive hand movements before and after levodopa intake. High-frequency oscillation power was compared across epochs containing rest tremor, tremor-free rest, or voluntary movement and related to the tremor cycle. We observed prominent slow (200-300 Hz) and fast (300-400 Hz) high-frequency oscillations. The ratio between slow and fast high-frequency oscillation power increased when tremor became manifest. This increase was consistent across nuclei (94%) and occurred in medication ON and OFF. The ratio outperformed other potential markers of tremor, such as power at individual tremor frequency, beta power, or low gamma power. For voluntary movement, we did not observe a significant difference when compared with rest or rest tremor. Finally, rhythmic modulations of high-frequency oscillation power occurred within the tremor cycle. Subthalamic high-frequency oscillation power is closely linked to the occurrence of parkinsonian rest tremor. The balance between slow and fast high-frequency oscillation power combines information on motor and medication state. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Complementary spectroscopic studies of materials of security interest
NASA Astrophysics Data System (ADS)
Burnett, Andrew; Fan, Wenhui; Upadhya, Prashanth; Cunningham, John; Edwards, Howell; Munshi, Tasnim; Hargreaves, Michael; Linfield, Edmund; Davies, Giles
2006-09-01
We demonstrate that, through coherent measurement of the transmitted terahertz frequency electric fields, broadband (0.3 - 8 THz) time-domain spectroscopy can be used to measure far-infrared vibrational modes of a range of drugs-of-abuse and high explosives that are of interest to the forensic and security services. Our results indicate that absorption features in these materials are highly sensitive to the structural and spatial arrangement of the molecules. Terahertz frequency spectra are also compared with high-resolution low-frequency Raman spectra to assist in understanding the low-frequency inter- and intra-molecular vibrational modes of the molecules.
Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.
1992-01-01
In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.
Sensitive high frequency hearing in earless and partially eared harlequin frogs (Atelopus).
Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Hoke, Kim L
2018-04-19
Harlequin frogs, genus Atelopus , communicate at high frequencies despite most species lacking a complete tympanic middle ear that facilitates high frequency hearing in most anurans and other tetrapods. Here we test whether Atelopus are better at sensing high frequency acoustic sound compared to other eared and earless species in the Bufonidae family, determine whether middle ear variation within Atelopus affects hearing sensitivity, and test potential hearing mechanisms in Atelopus We determine that at high frequencies (2000-4000 Hz) Atelopus are 10-34 dB more sensitive than other earless bufonids but are relatively insensitive to mid-range frequencies (900-1500 Hz) compared to eared bufonids. Hearing among Atelopus species is fairly consistent, evidence that the partial middle ears present in a subset of Atelopus species do not convey a substantial hearing advantage. We further demonstrate that Atelopus hearing is not likely facilitated by vibration of the skin overlying the normal tympanic membrane region or the body lung wall, leaving the extratympanic hearing pathways in Atelopus enigmatic. Together these results show Atelopus have sensitive high frequency hearing without the aid of a tympanic middle ear and prompt further study of extratympanic hearing mechanisms in anurans. © 2018. Published by The Company of Biologists Ltd.
Automatic seizure detection in SEEG using high frequency activities in wavelet domain.
Ayoubian, L; Lacoma, H; Gotman, J
2013-03-01
Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80-500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Automatic seizure detection in SEEG using high frequency activities in wavelet domain
Ayoubian, L.; Lacoma, H.; Gotman, J.
2015-01-01
Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80–500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. PMID:22647836
In vivo, high-frequency three-dimensional cardiac MR elastography: Feasibility in normal volunteers.
Arani, Arvin; Glaser, Kevin L; Arunachalam, Shivaram P; Rossman, Phillip J; Lake, David S; Trzasko, Joshua D; Manduca, Armando; McGee, Kiaran P; Ehman, Richard L; Araoz, Philip A
2017-01-01
Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. This study motivates future evaluation of high-frequency 3D MRE in patient populations. Magn Reson Med 77:351-360, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
High-Frequency Response and Voltage Noise in Magnetic Nanocomposites
NASA Astrophysics Data System (ADS)
Buznikov, N. A.; Iakubov, I. T.; Rakhmanov, A. L.; Kugel, K. I.; Sboychakov, A. O.
We study the noise spectra and high-frequency permeability of inhomogeneous magnetic materials consisting of single-domain magnetic nanoparticles embedded into an insulating matrix. Possible mechanisms of 1/f voltage noise in phase-separated manganites is analyzed. The material is modelled by a system of small ferromagnetic metallic droplets (magnetic polarons or ferrons) in insulating antiferromagnetic or paramagnetic matrix. The electron transport is related to tunnelling of charge carriers between droplets. One of the sources of the 1/f noise in such a system stems from fluctuations of the number of droplets with extra electron. In the case of strong magnetic anisotropy, the 1/f noise can arise also due to the fluctuations of the magnetic moments of ferrons. The high frequency magnetic permeability of nanocomposite film with magnetic particles in insulating non-magnetic matrix is studied in detail. The case of strong magnetic dipole interaction and strong magnetic anisotropy of ferromagnetic granules is considered. The composite is modelled by a cubic regular array of ferromagnetic particles. The high-frequency permeability tensor components are found as a functions of frequency, temperature, ferromagnetic phase content, and magnetic anisotropy. The results demonstrate that magnetic dipole interaction leads to a shift of the resonance frequencies towards higher values, and nanocomposite film could have rather high value of magnetic permeability in the microwave range.
High-Frequency Response and Voltage Noise in Magnetic Nanocomposites
NASA Astrophysics Data System (ADS)
Buznikov, N. A.; Iakubov, I. T.; Rakhmanov, A. L.; Kugel, K. I.; Sboychakov, A. O.
2010-12-01
We study the noise spectra and high-frequency permeability of inhomogeneous magnetic materials consisting of single-domain magnetic nanoparticles embedded into an insulating matrix. Possible mechanisms of 1/f voltage noise in phase-separated manganites is analyzed. The material is modelled by a system of small ferromagnetic metallic droplets (magnetic polarons or ferrons) in insulating antiferromagnetic or paramagnetic matrix. The electron transport is related to tunnelling of charge carriers between droplets. One of the sources of the 1/f noise in such a system stems from fluctuations of the number of droplets with extra electron. In the case of strong magnetic anisotropy, the 1/f noise can arise also due to the fluctuations of the magnetic moments of ferrons. The high frequency magnetic permeability of nanocomposite film with magnetic particles in insulating non-magnetic matrix is studied in detail. The case of strong magnetic dipole interaction and strong magnetic anisotropy of ferromagnetic granules is considered. The composite is modelled by a cubic regular array of ferromagnetic particles. The high-frequency permeability tensor components are found as a functions of frequency, temperature, ferromagnetic phase content, and magnetic anisotropy. The results demonstrate that magnetic dipole interaction leads to a shift of the resonance frequencies towards higher values, and nanocomposite film could have rather high value of magnetic permeability in the microwave range.
Korean Word Frequency and Commonality Study for Augmentative and Alternative Communication
ERIC Educational Resources Information Center
Shin, Sangeun; Hill, Katya
2016-01-01
Background: Vocabulary frequency results have been reported to design and support augmentative and alternative communication (AAC) interventions. A few studies exist for adult speakers and for other natural languages. With the increasing demand on AAC treatment for Korean adults, identification of high-frequency or core vocabulary (CV) becomes…
ERIC Educational Resources Information Center
Faes, Jolien; Gillis, Joris; Gillis, Steven
2017-01-01
The frequency of occurrence of words and sounds has a pervasive influence on typically developing children's language acquisition. For instance, highly frequent words appear earliest in a child's lexicon, and highly frequent phonemes are produced more accurately. This study evaluates (a) whether word frequency influences word accuracy and (b)…
Sustainable limitation of high-frequency oscillations of elevator cabin
NASA Astrophysics Data System (ADS)
Kaytukov, Batraz
2017-10-01
In this paper, a problem of sustainable limitation of vertical high-frequency oscillations of elevator cabin in buildings with various number of storeys is considered. To solve this problem, dynamic model of the elevator movement was developed. In the course of analytical and experimental studies, the main cause for emergence of undesirable high-frequency oscillations of a cabin was defined. The amplification factor which is the function of λ and length of cable was determined. The λ parameter is variable, and length of the cable changes depending on length passed by the cabin and is an amplification factor argument. For sustainable limitation of oscillations, use of dynamic dumper of lever type is proposed. Adjustment of the dumper natural vibration frequency in such a way that it is equal to the excitation frequency allows limiting of oscillations of the cabin and the elevator machine to reasonable value irrespective to position of a moving cabin in the shaft. Using dependences and plots which were obtained in the course of scientific analysis and experimental studies, reasonability of dumper application for sustainable limitation of high-frequency influence of the elevator machine on the base and obtaining of solutions of inertial forces equilibration problem was proved.
2015-01-01
The recent availability of high frequency data has permitted more efficient ways of computing volatility. However, estimation of volatility from asset price observations is challenging because observed high frequency data are generally affected by noise-microstructure effects. We address this issue by using the Fourier estimator of instantaneous volatility introduced in Malliavin and Mancino 2002. We prove a central limit theorem for this estimator with optimal rate and asymptotic variance. An extensive simulation study shows the accuracy of the spot volatility estimates obtained using the Fourier estimator and its robustness even in the presence of different microstructure noise specifications. An empirical analysis on high frequency data (U.S. S&P500 and FIB 30 indices) illustrates how the Fourier spot volatility estimates can be successfully used to study intraday variations of volatility and to predict intraday Value at Risk. PMID:26421617
NASA Astrophysics Data System (ADS)
Bieroza, Magdalena
2017-04-01
High-frequency nutrient (phosphorus and nitrogen) monitoring using wet-chemistry analysers and optical sensors has revolutionised the collection of biogeochemical data from streams, rivers and lakes. Matching the nutrient measurement time with timescales of hydrological responses has revealed biogeochemical patterns and nutrient hydrological responses not observed previously. Capturing a wider range of nutrient concentrations compared to traditional coarse resolution sampling enables more accurate estimation of mean concentrations and loads and thus improved water body classification. However, to date the scientific insights from the high-frequency nutrient monitoring studies have not been translated into policy and operational responses. The pertinent question is where and how often to measure nutrients to satisfy statutory monitoring requirements for the Water Framework Directive and the Nitrates Directive. Therefore this paper discusses how the reduced data uncertainty and improved process understanding obtained with the high-frequency measurements can improve statutory nutrient monitoring, using case studies from England and Sweden.
Correlated evolution between hearing sensitivity and social calls in bats
Bohn, Kirsten M; Moss, Cynthia F; Wilkinson, Gerald S
2006-01-01
Echolocating bats are auditory specialists, with exquisite hearing that spans several octaves. In the ultrasonic range, bat audiograms typically show highest sensitivity in the spectral region of their species-specific echolocation calls. Well-developed hearing in the audible range has been commonly attributed to a need to detect sounds produced by prey. However, bat pups often emit isolation calls with low-frequency components that facilitate mother–young reunions. In this study, we examine whether low-frequency hearing in bats exhibits correlated evolution with (i) body size; (ii) high-frequency hearing sensitivity or (iii) pup isolation call frequency. Using published audiograms, we found that low-frequency hearing sensitivity is not dependent on body size but is related to high-frequency hearing. After controlling for high-frequency hearing, we found that low-frequency hearing exhibits correlated evolution with isolation call frequency. We infer that detection and discrimination of isolation calls have favoured enhanced low-frequency hearing because accurate parental investment is critical: bats have low reproductive rates, non-volant altricial young and must often identify their pups within large crèches. PMID:17148288
Processing of simple and complex acoustic signals in a tonotopically organized ear
Hummel, Jennifer; Wolf, Konstantin; Kössl, Manfred; Nowotny, Manuela
2014-01-01
Processing of complex signals in the hearing organ remains poorly understood. This paper aims to contribute to this topic by presenting investigations on the mechanical and neuronal response of the hearing organ of the tropical bushcricket species Mecopoda elongata to simple pure tone signals as well as to the conspecific song as a complex acoustic signal. The high-frequency hearing organ of bushcrickets, the crista acustica (CA), is tonotopically tuned to frequencies between about 4 and 70 kHz. Laser Doppler vibrometer measurements revealed a strong and dominant low-frequency-induced motion of the CA when stimulated with either pure tone or complex stimuli. Consequently, the high-frequency distal area of the CA is more strongly deflected by low-frequency-induced waves than by high-frequency-induced waves. This low-frequency dominance will have strong effects on the processing of complex signals. Therefore, we additionally studied the neuronal response of the CA to native and frequency-manipulated chirps. Again, we found a dominant influence of low-frequency components within the conspecific song, indicating that the mechanical vibration pattern highly determines the neuronal response of the sensory cells. Thus, we conclude that the encoding of communication signals is modulated by ear mechanics. PMID:25339727
Moore, Brian C J; Stone, Michael A; Füllgrabe, Christian; Glasberg, Brian R; Puria, Sunil
2008-12-01
It is possible for auditory prostheses to provide amplification for frequencies above 6 kHz. However, most current hearing-aid fitting procedures do not give recommended gains for such high frequencies. This study was intended to provide information that could be useful in quantifying appropriate high-frequency gains, and in establishing the population of hearing-impaired people who might benefit from such amplification. The study had two parts. In the first part, wide-bandwidth recordings of normal conversational speech were obtained from a sample of male and female talkers. The recordings were used to determine the mean spectral shape over a wide frequency range, and to determine the distribution of levels (the speech dynamic range) as a function of center frequency. In the second part, audiometric thresholds were measured for frequencies of 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, and 12.5 kHz for both ears of 31 people selected to have mild or moderate cochlear hearing loss. The hearing loss was never greater than 70 dB for any frequency up to 4 kHz. The mean spectrum level of the speech fell progressively with increasing center frequency above about 0.5 kHz. For speech with an overall level of 65 dB SPL, the mean 1/3-octave level was 49 and 37 dB SPL for center frequencies of 1 and 10 kHz, respectively. The dynamic range of the speech was similar for center frequencies of 1 and 10 kHz. The part of the dynamic range below the root-mean-square level was larger than reported in previous studies. The mean audiometric thresholds at high frequencies (10 and 12.5 kHz) were relatively high (69 and 77 dB HL, respectively), even though the mean thresholds for frequencies below 4 kHz were 41 dB HL or better. To partially restore audibility for a hearing loss of 65 dB at 10 kHz would require an effective insertion gain of about 36 dB at 10 kHz. With this gain, audibility could be (partly) restored for 25 of the 62 ears assessed.
Metronidazole as a protector of cells from electromagnetic radiation of extremely high frequencies
NASA Astrophysics Data System (ADS)
Kuznetsov, Pavel E.; Malinina, Ulia A.; Popyhova, Era B.; Rogacheva, Svetlana M.; Somov, Alexander U.
2006-08-01
It is well known that weak electromagnetic fields of extremely high frequencies cause significant modification of the functional status of biological objects of different levels of organization. The aim of the work was to study the combinatory effect of metronidazole - the drug form of 1-(2'hydroxiethil)-2-methil-5-nitroimidazole - and electromagnetic radiation of extremely high frequencies (52...75 GHz) on the hemolytic stability of erythrocytes and hemotaxis activity of Infusoria Paramecium caudatum.
High frequency ultrasound with color Doppler in dermatology*
Barcaui, Elisa de Oliveira; Carvalho, Antonio Carlos Pires; Lopes, Flavia Paiva Proença Lobo; Piñeiro-Maceira, Juan; Barcaui, Carlos Baptista
2016-01-01
Ultrasonography is a method of imaging that classically is used in dermatology to study changes in the hypoderma, as nodules and infectious and inflammatory processes. The introduction of high frequency and resolution equipments enabled the observation of superficial structures, allowing differentiation between skin layers and providing details for the analysis of the skin and its appendages. This paper aims to review the basic principles of high frequency ultrasound and its applications in different areas of dermatology. PMID:27438191
Is there a first night effect on sleep bruxism? A sleep laboratory study.
Hasegawa, Yoko; Lavigne, Gilles; Rompré, Pierre; Kato, Takafumi; Urade, Masahiro; Huynh, Nelly
2013-11-15
Sleep bruxism (SB) is reported to vary in frequency over time. The aim of this study was to assess the first night effect on SB. A retrospective polysomnographic (PSG) analysis was performed of data from a sample of SB patients (12 females, 4 males; age range: 17-39 years) recorded in a sleep laboratory over 2 consecutive nights. Sleep parameters and jaw muscle activity variables (i.e., rhythmic masticatory muscle activity [RMMA]) for SB were quantified and compared between the 2 nights. Subjects were classified into groups according to severity of RMMA frequency, such as low frequency (2-4 episodes/h and/or < 25 bursts/h) and moderate-high frequency (≥ 4 episodes/h and ≥ 25 bursts/h). Overall, no first night effects were found for most sleep variables. However, total sleep time, sleep efficiency, and stage transitions showed significant time and group interactions (repeated measures ANOVAs, p ≤ 0.05). The RMMA episode index did not differ between the 2 nights, whereas the second night showed significantly higher burst index, bruxism time index, and mean burst duration (repeated measure ANOVAs, p ≤ 0.05). Five patients of 8 in the low frequency group were classified into the moderate-high frequency group on the second night, whereas only one patient in the moderate-high frequency group moved to the low frequency group. The results showed no overall first night effect on severity of RMMA frequency in young and healthy patients with SB. In clinical practice, one-night sleep recording may be sufficient for moderate-high frequency SB patients. However, low RMMA frequency in the first night could be confirmed by a second night based on the patient's medical and dental history.
Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals
Xiang, Jing; Luo, Qian; Kotecha, Rupesh; Korman, Abraham; Zhang, Fawen; Luo, Huan; Fujiwara, Hisako; Hemasilpin, Nat; Rose, Douglas F.
2014-01-01
Recent studies have revealed the importance of high-frequency brain signals (>70 Hz). One challenge of high-frequency signal analysis is that the size of time-frequency representation of high-frequency brain signals could be larger than 1 terabytes (TB), which is beyond the upper limits of a typical computer workstation's memory (<196 GB). The aim of the present study is to develop a new method to provide greater sensitivity in detecting high-frequency magnetoencephalography (MEG) signals in a single automated and versatile interface, rather than the more traditional, time-intensive visual inspection methods, which may take up to several days. To address the aim, we developed a new method, accumulated source imaging, defined as the volumetric summation of source activity over a period of time. This method analyzes signals in both low- (1~70 Hz) and high-frequency (70~200 Hz) ranges at source levels. To extract meaningful information from MEG signals at sensor space, the signals were decomposed to channel-cross-channel matrix (CxC) representing the spatiotemporal patterns of every possible sensor-pair. A new algorithm was developed and tested by calculating the optimal CxC and source location-orientation weights for volumetric source imaging, thereby minimizing multi-source interference and reducing computational cost. The new method was implemented in C/C++ and tested with MEG data recorded from clinical epilepsy patients. The results of experimental data demonstrated that accumulated source imaging could effectively summarize and visualize MEG recordings within 12.7 h by using approximately 10 GB of computer memory. In contrast to the conventional method of visually identifying multi-frequency epileptic activities that traditionally took 2–3 days and used 1–2 TB storage, the new approach can quantify epileptic abnormalities in both low- and high-frequency ranges at source levels, using much less time and computer memory. PMID:24904402
Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals.
Xiang, Jing; Luo, Qian; Kotecha, Rupesh; Korman, Abraham; Zhang, Fawen; Luo, Huan; Fujiwara, Hisako; Hemasilpin, Nat; Rose, Douglas F
2014-01-01
Recent studies have revealed the importance of high-frequency brain signals (>70 Hz). One challenge of high-frequency signal analysis is that the size of time-frequency representation of high-frequency brain signals could be larger than 1 terabytes (TB), which is beyond the upper limits of a typical computer workstation's memory (<196 GB). The aim of the present study is to develop a new method to provide greater sensitivity in detecting high-frequency magnetoencephalography (MEG) signals in a single automated and versatile interface, rather than the more traditional, time-intensive visual inspection methods, which may take up to several days. To address the aim, we developed a new method, accumulated source imaging, defined as the volumetric summation of source activity over a period of time. This method analyzes signals in both low- (1~70 Hz) and high-frequency (70~200 Hz) ranges at source levels. To extract meaningful information from MEG signals at sensor space, the signals were decomposed to channel-cross-channel matrix (CxC) representing the spatiotemporal patterns of every possible sensor-pair. A new algorithm was developed and tested by calculating the optimal CxC and source location-orientation weights for volumetric source imaging, thereby minimizing multi-source interference and reducing computational cost. The new method was implemented in C/C++ and tested with MEG data recorded from clinical epilepsy patients. The results of experimental data demonstrated that accumulated source imaging could effectively summarize and visualize MEG recordings within 12.7 h by using approximately 10 GB of computer memory. In contrast to the conventional method of visually identifying multi-frequency epileptic activities that traditionally took 2-3 days and used 1-2 TB storage, the new approach can quantify epileptic abnormalities in both low- and high-frequency ranges at source levels, using much less time and computer memory.
NASA Astrophysics Data System (ADS)
Bryk, Taras; Demchuk, Taras; Jakse, Noël; Wax, Jean-François
2018-02-01
Recent findings of pressure-induced emergence of unusual high-frequency contribution to transverse current spectral functions in several simple liquid metals at high pressures raised a question whether similar features can be observed in liquid metals at ambient conditions. We report here analysis of ab initio molecular dynamics-derived longitudinal (L) and transverse (T) current spectral functions and corresponding dispersions of collective excitations in liquid polyvalent metals Al, Tl, Ni. We have not found evidences of the second branch of high-frequency transverse modes in liquid Al and Ni, while in the case of liquid Tl they were clearly present in transverse dynamics. The vibrational density of states for liquid Tl has a pronounced high-frequency shoulder, which is located right in the frequency range of the second high-frequency transverse branch, while for liquid Al and Ni the vibrational density of states has only a weak indication of possible high-frequency shoulder. The origin of specific behavior of transverse excitations in liquid Tl is discussed.
NASA Technical Reports Server (NTRS)
Wieserman, W. R.; Schwarze, G. E.; Niedra, J. M.
1990-01-01
Limited experimental data exists for the specific core loss and dynamic B-H loops for soft magnetic materials for the combined conditions of high frequency and high temperature. This experimental study investigates the specific core loss and dynamic B-H loop characteristics of Supermalloy and Metglas 2605SC over the frequency range of 1 to 50 kHz and temperature range of 23 to 300 C under sinusoidal voltage excitation. The experimental setup used to conduct the investigation is described. The effects of the maximum magnetic flux density, frequency, and temperature on the specific core loss and on the size and shape of the B-H loops are examined.
Linear viscoelasticity of a single semiflexible polymer with internal friction.
Hiraiwa, Tetsuya; Ohta, Takao
2010-07-28
The linear viscoelastic behaviors of single semiflexible chains with internal friction are studied based on the wormlike-chain model. It is shown that the frequency dependence of the complex compliance in the high frequency limit is the same as that of the Voigt model. This asymptotic behavior appears also for the Rouse model with internal friction. We derive the characteristic times for both the high frequency limit and the low frequency limit and compare the results with those obtained by Khatri et al.
The Impact of Attention on Judgments of Frequency and Duration
Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter
2015-01-01
Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested. PMID:26000712
The impact of attention on judgments of frequency and duration.
Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter
2015-01-01
Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested.
Parametric Study of High Frequency Pulse Detonation Tubes
NASA Technical Reports Server (NTRS)
Cutler, Anderw D.
2008-01-01
This paper describes development of high frequency pulse detonation tubes similar to a small pulse detonation engine (PDE). A high-speed valve injects a charge of a mixture of fuel and air at rates of up to 1000 Hz into a constant area tube closed at one end. The reactants detonate in the tube and the products exit as a pulsed jet. High frequency pressure transducers are used to monitor the pressure fluctuations in the device and thrust is measured with a balance. The effects of injection frequency, fuel and air flow rates, tube length, and injection location are considered. Both H2 and C2H4 fuels are considered. Optimum (maximum specific thrust) fuel-air compositions and resonant frequencies are identified. Results are compared to PDE calculations. Design rules are postulated and applications to aerodynamic flow control and propulsion are discussed.
A neuroimaging study of conflict during word recognition.
Riba, Jordi; Heldmann, Marcus; Carreiras, Manuel; Münte, Thomas F
2010-08-04
Using functional magnetic resonance imaging the neural activity associated with error commission and conflict monitoring in a lexical decision task was assessed. In a cohort of 20 native speakers of Spanish conflict was introduced by presenting words with high and low lexical frequency and pseudo-words with high and low syllabic frequency for the first syllable. Erroneous versus correct responses showed activation in the frontomedial and left inferior frontal cortex. A similar pattern was found for correctly classified words of low versus high lexical frequency and for correctly classified pseudo-words of high versus low syllabic frequency. Conflict-related activations for language materials largely overlapped with error-induced activations. The effect of syllabic frequency underscores the role of sublexical processing in visual word recognition and supports the view that the initial syllable mediates between the letter and word level.
Thompson, William R; Keller, Benjamin V; Davis, Matthew L; Dahners, Laurence E; Weinhold, Paul S
2015-05-01
Low-magnitude, high-frequency vibration accelerates fracture and wound healing and prevents disuse atrophy in musculoskeletal tissues. To investigate the role of low-magnitude, high-frequency vibration as a treatment to accelerate healing of an acute ligament injury and to examine gene expression in the intact Achilles tendon of the injured limb after low-magnitude, high-frequency vibration. Controlled laboratory study. Complete surgical transection of the medial collateral ligament (MCL) was performed in 32 Sprague-Dawley rats, divided into control and low-magnitude, high-frequency vibration groups. Low-magnitude, high-frequency vibration started on postoperative day 2, and rats received vibration for 30 minutes a day for 12 days. All rats were sacrificed 2 weeks after the operation, and their intact and injured MCLs were biomechanically tested or used for histological analysis. Intact Achilles tendons from the injured limb were evaluated for differences in gene expression. Mechanical testing revealed no differences in the ultimate tensile load or the structural stiffness between the control and vibration groups for either the injured or intact MCL. Vibration exposure increased gene expression of collagen 1 alpha (3-fold), interleukin 6 (7-fold), cyclooxygenase 2 (5-fold), and bone morphogenetic protein 12 (4-fold) in the intact Achilles tendon when compared with control tendons ( P < .05). While no differences were observed in the mechanical or histological properties of the fully transected MCL after low-magnitude, high-frequency vibration treatment, significant enhancements in gene expression were observed in the intact Achilles tendon. These included collagen, several inflammatory cytokines, and growth factors critical for tendons. As low-magnitude, high-frequency vibration had no negative effects on ligament healing, vibration therapy may be a useful tool to accelerate healing of other tissues (bone) in multitrauma injuries without inhibiting ligament healing. Additionally, the enhanced gene expression in response to low-magnitude, high-frequency vibration in the intact Achilles tendon suggests the need to further study its potential to accelerate tendon healing in partial injury or repair models.
Flow and Acoustic Features of a Mach 0.9 Free Jet Using High-Frequency Excitation
NASA Astrophysics Data System (ADS)
Upadhyay, Puja; Alvi, Farrukh
2016-11-01
This study focuses on active control of a Mach 0.9 (ReD = 6 ×105) free jet using high-frequency excitation for noise reduction. Eight resonance-enhanced microjet actuators with nominal frequencies of 25 kHz (StD 2 . 2) are used to excite the shear layer at frequencies that are approximately an order of magnitude higher than the jet preferred frequency. The influence of control on mean and turbulent characteristics of the jet is studied using Particle Image Velocimetry. Additionally, far-field acoustic measurements are acquired to estimate the effect of pulsed injection on noise characteristics of the jet. Flow field measurements revealed that strong streamwise vortex pairs, formed as a result of control, result in a significantly thicker initial shear layer. This excited shear layer is also prominently undulated, resulting in a modified initial velocity profile. Also, the distribution of turbulent kinetic energy revealed that forcing results in increased turbulence levels for near-injection regions, followed by a global reduction for all downstream locations. Far-field acoustic measurements showed noise reductions at low to moderate frequencies. Additionally, an increase in high-frequency noise, mostly dominated by the actuators' resonant noise, was observed. AFOSR and ARO.
Zarei, Ali Asghar; Foroutan, Seyyed Abbas; Foroutan, Seyyed Mohsen; Erfanian Omidvar, Abbas
2011-01-01
Pyridostigmine bromide (PB) is a reversible cholinesterase inhibitor. The aim of this study was to determine the effect of orally administration of single dose sustained-released tablet of pyridostigmine bromide (PBSR) on the frequency domain indices of heart rate variability (HRV). Thirty-two healthy young men were participated in this study. They were divided into 2 groups; the pyridostigmine group (n = 22) and the placebo group (n = 10). Electrocardiogram (ECG) was recorded at 10, 30, 60, 90, 120, 150, 180, 210, 240, 300 and 420 min after PBSR administration. At each time, simultaneously, a blood sample was prepared and PB plasma concentration was measured by high-performance liquid chromatography (HPLC) method. Statistical analysis showed that in different indices of HRV, there is a significant increase in low frequency (LF) band at 300 min, but no difference in high frequency band (HF). It also showed significant decreases in normalized high frequency band (Hfnu), normalized low frequency band (Lfnu) and LF/HF ratio at 120, 240 and 300 min after PBSR administration. Maximum plasma concentration of PB was 150 min after the administration. In conclusion, administration of a single dose PBSR can enhance the frequency domains indices of HRV and improvesympathovagal balance.
The effect of sampling rate and anti-aliasing filters on high-frequency response spectra
Boore, David M.; Goulet, Christine
2013-01-01
The most commonly used intensity measure in ground-motion prediction equations is the pseudo-absolute response spectral acceleration (PSA), for response periods from 0.01 to 10 s (or frequencies from 0.1 to 100 Hz). PSAs are often derived from recorded ground motions, and these motions are usually filtered to remove high and low frequencies before the PSAs are computed. In this article we are only concerned with the removal of high frequencies. In modern digital recordings, this filtering corresponds at least to an anti-aliasing filter applied before conversion to digital values. Additional high-cut filtering is sometimes applied both to digital and to analog records to reduce high-frequency noise. Potential errors on the short-period (high-frequency) response spectral values are expected if the true ground motion has significant energy at frequencies above that of the anti-aliasing filter. This is especially important for areas where the instrumental sample rate and the associated anti-aliasing filter corner frequency (above which significant energy in the time series is removed) are low relative to the frequencies contained in the true ground motions. A ground-motion simulation study was conducted to investigate these effects and to develop guidance for defining the usable bandwidth for high-frequency PSA. The primary conclusion is that if the ratio of the maximum Fourier acceleration spectrum (FAS) to the FAS at a frequency fsaa corresponding to the start of the anti-aliasing filter is more than about 10, then PSA for frequencies above fsaa should be little affected by the recording process, because the ground-motion frequencies that control the response spectra will be less than fsaa . A second topic of this article concerns the resampling of the digital acceleration time series to a higher sample rate often used in the computation of short-period PSA. We confirm previous findings that sinc-function interpolation is preferred to the standard practice of using linear time interpolation for the resamplin
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.; Zhang, Y. S.
1991-01-01
In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.
On High and Low Starting Frequencies of Type II Radio Bursts
NASA Astrophysics Data System (ADS)
Sharma, J.; Mittal, N.
2017-06-01
We have studied the characteristics of type II radio burst during the period May 1996 to March 2015, for the solar cycle 23 and 24, observed by WIND/WAVES radio instrument. A total of 642 events were recorded by the instrument during the study period. We have divided the events with two starting frequency range (high > 1 MHz; low ≤ 1MHz) as type II1 (i.e., 1-16 MHz) radio burst and type II2 (i.e., 20 KHz - 1020 KHz) radio burst which constitute the DH and km type II radio burst observed by WIND spacecraft, and determined their time and frequency characteristics. The mean drift rate of type II1 and type II2 radio bursts is 29.76 × 10-4 MHz/s and 0.17 × 10-4 MHz/s respectively, which shows that type II1 with high start frequency hase larger drift rate than the type II2 with low starting frequencies. We have also reported that the start frequency and the drift rate of type II1 are in good correlation, with a linear correlation coefficient of 0.58.
NASA Astrophysics Data System (ADS)
Geng, Yong; Huang, Xiatao; Cui, Wenwen; Ling, Yun; Xu, Bo; Zhang, Jin; Yi, Xingwen; Wu, Baojian; Huang, Shu-Wei; Qiu, Kun; Wong, Chee Wei; Zhou, Heng
2018-05-01
We demonstrate seamless channel multiplexing and high bitrate superchannel transmission of coherent optical orthogonal-frequency-division-multiplexing (CO-OFDM) data signals utilizing a dissipative Kerr soliton (DKS) frequency comb generated in an on-chip microcavity. Aided by comb line multiplication through Nyquist pulse modulation, the high stability and mutual coherence among mode-locked Kerr comb lines are exploited for the first time to eliminate the guard intervals between communication channels and achieve full spectral density bandwidth utilization. Spectral efficiency as high as 2.625 bit/Hz/s is obtained for 180 CO-OFDM bands encoded with 12.75 Gbaud 8-QAM data, adding up to total bitrate of 6.885 Tb/s within 2.295 THz frequency comb bandwidth. Our study confirms that high coherence is the key superiority of Kerr soliton frequency combs over independent laser diodes, as a multi-spectral coherent laser source for high-bandwidth high-spectral-density transmission networks.
Shi, Miao; Qi, Hengtao; Ding, Hongyu; Chen, Feng; Xin, Zhaoqin; Zhao, Qinghua; Guan, Shibing; Shi, Hao
2018-01-01
Abstract This study aims to evaluate the value of electrophysiological examination and high frequency ultrasonography in the differential diagnosis of radial nerve torsion and radial nerve compression. Patients with radial nerve torsion (n = 14) and radial nerve compression (n = 14) were enrolled. The results of neurophysiological and high frequency ultrasonography were compared. Electrophysiological examination and high-frequency ultrasonography had a high diagnostic rate for both diseases with consistent results. Of the 28 patients, 23 were positive for electrophysiological examination, showing decreased amplitude and decreased conduction velocity of radial nerve; however, electrophysiological examination cannot distinguish torsion from compression. A total of 27 cases showed positive in ultrasound examinations among all 28 cases. On ultrasound images, the nerve was thinned at torsion site whereas thickened at the distal ends of torsion. The diameter and cross-sectional area of torsion or compression determined the nerve damage, and ultrasound could locate the nerve injury site and measure the length of the nerve. Electrophysiological examination and high-frequency ultrasonography can diagnose radial neuropathy, with electrophysiological examination reflecting the neurological function, and high-frequency ultrasound differentiating nerve torsion from compression. PMID:29480857
Castellanos-Ryan, Natalie; Pingault, Jean-Baptiste; Parent, Sophie; Vitaro, Frank; Tremblay, Richard E; Séguin, Jean R
2017-10-01
The main objective of this prospective longitudinal study was to investigate bidirectional associations between adolescent cannabis use (CU) and neurocognitive performance in a community sample of 294 young men from ages 13 to 20 years. The results showed that in early adolescence, and prior to initiation to CU, poor short-term and working memory, but high verbal IQ, were associated with earlier age of onset of CU. In turn, age of CU onset and CU frequency across adolescence were associated with (a) specific neurocognitive decline in verbal IQ and executive function tasks tapping trial and error learning and reward processing by early adulthood and (b) lower rates of high-school graduation. The association between CU onset and change in neurocognitive function, however, was found to be accounted for by CU frequency. Whereas the link between CU frequency across adolescence and change in verbal IQ was explained (mediated) by high school graduation, the link between CU frequency and tasks tapping trial and error learning were independent from high school graduation, concurrent cannabis and other substance use, adolescent alcohol use, and externalizing behaviors. Findings support prevention efforts aimed at delaying onset and reducing frequency of CU.
Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: an in vitro study
NASA Astrophysics Data System (ADS)
Suo, Dingjie; Guo, Sijia; Lin, Weili; Jiang, Xiaoning; Jing, Yun
2015-09-01
High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free treatment approach for ischemic stroke. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation. In this study, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were introduced as HIFU excitations to reduce the required power for treatment as well as the treatment time. In vitro bovine blood clots weighing around 150 mg were treated by single-frequency and multi-frequency HIFU. The pulse length was 2 ms for all experiments except the ones where the duty cycle was changed. It was found that dual-frequency thrombolysis efficiency was statistically better than single-frequency under the same acoustic power and excitation condition. When varying the acoustic power but fixing the duty cycle at 5%, it was found that dual-frequency ultrasound can save almost 30% power in order to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of single-frequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2-4 as demonstrated in this study. No significant differences were found between dual-frequencies with different frequency differences (0.025, 0.05, and 0.1 MHz) and between dual-frequency and triple-frequency. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level but both were significantly higher than that of single-frequency.
The neural bases of spatial frequency processing during scene perception
Kauffmann, Louise; Ramanoël, Stephen; Peyrin, Carole
2014-01-01
Theories on visual perception agree that scenes are processed in terms of spatial frequencies. Low spatial frequencies (LSF) carry coarse information whereas high spatial frequencies (HSF) carry fine details of the scene. However, how and where spatial frequencies are processed within the brain remain unresolved questions. The present review addresses these issues and aims to identify the cerebral regions differentially involved in low and high spatial frequency processing, and to clarify their attributes during scene perception. Results from a number of behavioral and neuroimaging studies suggest that spatial frequency processing is lateralized in both hemispheres, with the right and left hemispheres predominantly involved in the categorization of LSF and HSF scenes, respectively. There is also evidence that spatial frequency processing is retinotopically mapped in the visual cortex. HSF scenes (as opposed to LSF) activate occipital areas in relation to foveal representations, while categorization of LSF scenes (as opposed to HSF) activates occipital areas in relation to more peripheral representations. Concomitantly, a number of studies have demonstrated that LSF information may reach high-order areas rapidly, allowing an initial coarse parsing of the visual scene, which could then be sent back through feedback into the occipito-temporal cortex to guide finer HSF-based analysis. Finally, the review addresses spatial frequency processing within scene-selective regions areas of the occipito-temporal cortex. PMID:24847226
Noise in the passenger cars of high-speed trains.
Hong, Joo Young; Cha, Yongwon; Jeon, Jin Yong
2015-12-01
The aim of this study is to investigate the effects of both room acoustic conditions and spectral characteristics of noises on acoustic discomfort in a high-speed train's passenger car. Measurement of interior noises in a high-speed train was performed when the train was operating at speeds of 100 km/h and 300 km/h. Acoustic discomfort caused by interior noises was evaluated by paired comparison methods based on the variation of reverberation time (RT) in a passenger car and the spectral differences in interior noises. The effect of RT on acoustic discomfort was not significant, whereas acoustic discomfort significantly varied depending on spectral differences in noise. Acoustic discomfort increased with increment of the sound pressure level (SPL) ratio at high frequencies, and variation in high-frequency noise components were described using sharpness. Just noticeable differences of SPL with low- and high-frequency components were determined to be 3.7 and 2.9 dB, respectively. This indicates that subjects were more sensitive to differences in SPLs at the high-frequency range than differences at the low-frequency range. These results support that, for interior noises, reduction in SPLs at high frequencies would significantly contribute to improved acoustic quality in passenger cars of high-speed trains.
The word frequency effect during sentence reading: A linear or nonlinear effect of log frequency?
White, Sarah J; Drieghe, Denis; Liversedge, Simon P; Staub, Adrian
2016-10-20
The effect of word frequency on eye movement behaviour during reading has been reported in many experimental studies. However, the vast majority of these studies compared only two levels of word frequency (high and low). Here we assess whether the effect of log word frequency on eye movement measures is linear, in an experiment in which a critical target word in each sentence was at one of three approximately equally spaced log frequency levels. Separate analyses treated log frequency as a categorical or a continuous predictor. Both analyses showed only a linear effect of log frequency on the likelihood of skipping a word, and on first fixation duration. Ex-Gaussian analyses of first fixation duration showed similar effects on distributional parameters in comparing high- and medium-frequency words, and medium- and low-frequency words. Analyses of gaze duration and the probability of a refixation suggested a nonlinear pattern, with a larger effect at the lower end of the log frequency scale. However, the nonlinear effects were small, and Bayes Factor analyses favoured the simpler linear models for all measures. The possible roles of lexical and post-lexical factors in producing nonlinear effects of log word frequency during sentence reading are discussed.
Fluctuation spectra in the NASA Lewis bumpy-torus plasma
NASA Technical Reports Server (NTRS)
Singh, C. M.; Krawczonek, W. M.; Roth, J. R.; Hong, J. Y.; Powers, E. J.
1978-01-01
The electrostatic potential fluctuation spectrum in the NASA Lewis bumpy-torus plasma was studied with capacitive probes in the low pressure (high impedance) mode and in the high pressure (low impedance) mode. Under different operating conditions, the plasma exhibited electrostatic potential fluctuations (1) at a set of discrete frequencies, (2) at a continuum of frequencies, and (3) as incoherent high-frequency turbulence. The frequencies and azimuthal wave numbers were determined from digitally implemented autopower and cross-power spectra. The azimuthal dispersion characteristics of the unstable waves were examined by varying the electrode voltage, the polarity of the voltage, and the neutral background density at a constant magnetic field strength.
Trends in Northern Hemisphere surface cyclone frequency and intensity
McCabe, G.J.; Clark, M.P.; Serreze, Mark C.
2001-01-01
One of the hypothesized effects of global warming from increasing concentrations of greenhouse gases is a change in the frequency and/or intensity of extratropical cyclones. In this study, winter frequencies and intensities of extratropical cyclones in the Northern Hemisphere for the period 1959-97 are examined to determine if identifiable trends are occurring. Results indicate a statistically significant decrease in midlatitude cyclone frequency and a significant increase in high-latitude cyclone frequency. In addition, storm intensity has increased in both the high and midlatitudes. The changes in storm frequency correlate with changes in winter Northern Hemisphere temperature and support hypotheses that global warming may result in a northward shift of storm tracks in the Northern Hemisphere.
Petrova, Ana; Gaskell, M. Gareth; Ferrand, Ludovic
2011-01-01
Many studies have repeatedly shown an orthographic consistency effect in the auditory lexical decision task. Words with phonological rimes that could be spelled in multiple ways (i.e., inconsistent words) typically produce longer auditory lexical decision latencies and more errors than do words with rimes that could be spelled in only one way (i.e., consistent words). These results have been extended to different languages and tasks, suggesting that the effect is quite general and robust. Despite this growing body of evidence, some psycholinguists believe that orthographic effects on spoken language are exclusively strategic, post-lexical, or restricted to peculiar (low-frequency) words. In the present study, we manipulated consistency and word-frequency orthogonally in order to explore whether the orthographic consistency effect extends to high-frequency words. Two different tasks were used: lexical decision and rime detection. Both tasks produced reliable consistency effects for both low- and high-frequency words. Furthermore, in Experiment 1 (lexical decision), an interaction revealed a stronger consistency effect for low-frequency words than for high-frequency words, as initially predicted by Ziegler and Ferrand (1998), whereas no interaction was found in Experiment 2 (rime detection). Our results extend previous findings by showing that the orthographic consistency effect is obtained not only for low-frequency words but also for high-frequency words. Furthermore, these effects were also obtained in a rime detection task, which does not require the explicit processing of orthographic structure. Globally, our results suggest that literacy changes the way people process spoken words, even for frequent words. PMID:22025916
Zhou, Ge; Liu, Hongjian; He, Minfu; Yue, Mengjia; Gong, Ping; Wu, Fangyuan; Li, Xuanxuan; Pang, Yingxin; Yang, Xiaodi; Ma, Juan; Liu, Meitian; Li, Jinghua; Zhang, Xiumin
2018-02-27
Physical activity (PA) and smoking have been reported to be associated with the duration and severity of common cold symptoms. However, few studies have addressed the associations between the frequency of leisure-time exercise, cigarette smoking status and the frequency of the common cold in a cold area. This study was designed to investigate these issues in northeastern China. This cross-sectional study included individuals who participated in a regular health examination conducted in Jilin Province, China. Information on episodes of the common cold, the frequency of leisure-time exercise and cigarette smoking status in the past year were collected by self-administered health questionnaires. Ordinal logistic regression models were used to analyse the associations between the frequency of leisure-time exercise, cigarette smoking status and the retrospective frequency of common cold. A total of 1413 employees participated in the study, with an average age of 38.92 ± 9.04 years and 44.4% of them were male. Of all participants, 80.8% reported having experienced the common cold in the past year. After adjustment, the risk of suffering from the common cold more than once (odds ratios (ORs), 1.59; 95% confidence interval (CI), 1.27-1.99) in passive smokers was 1.59 times as high as that in non-smokers. Nevertheless, the results of the adjusted analysis showed no statistically significant relation between current smoking and the frequency of the common cold. A high frequency of leisure-time exercise (≥3 days/week) was associated with a 26% reduced risk of having at least one episode of the common cold (OR, 0.74; 95% CI, 0.55-0.98) compared with a low frequency group (< 4 days/month). For current and passive smokers, the protective effect of a high frequency of leisure-time exercise appears not to be obvious (current smokers: OR, 0.68; 95% CI, 0.33-1.43; passive smokers: OR, 1.15; 95% CI, 0.69-1.93). Passive smoking was associated with a higher risk of having self-reported common cold at least once, while a high frequency of leisure-time exercise was related to a lower risk of reporting more than one episode of the disease in Chinese.
Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R
2016-04-18
To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-Gómez, David; Soler, Roberto; Terradas, Jaume, E-mail: david.martinez@uib.es
Ideal magnetohydrodynamics (MHD) provides an accurate description of low-frequency Alfvén waves in fully ionized plasmas. However, higher-frequency waves in many plasmas of the solar atmosphere cannot be correctly described by ideal MHD and a more accurate model is required. Here, we study the properties of small-amplitude incompressible perturbations in both the low- and the high-frequency ranges in plasmas composed of several ionized species. We use a multi-fluid approach and take into account the effects of collisions between ions and the inclusion of Hall’s term in the induction equation. Through the analysis of the corresponding dispersion relations and numerical simulations, wemore » check that at high frequencies ions of different species are not as strongly coupled as in the low-frequency limit. Hence, they cannot be treated as a single fluid. In addition, elastic collisions between the distinct ionized species are not negligible for high-frequency waves, since an appreciable damping is obtained. Furthermore, Coulomb collisions between ions remove the cyclotron resonances and the strict cutoff regions, which are present when collisions are not taken into account. The implications of these results for the modeling of high-frequency waves in solar plasmas are discussed.« less
Frequency of Guns in the Households of High School Seniors
ERIC Educational Resources Information Center
Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.
2017-01-01
Background: In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. Methods: In this cohort study of 3,006 high school seniors from 24 schools, we examined the frequency of household guns ownership. Results: About 65%…
Study of opto-acoustic communication between air and underwater carrier
NASA Astrophysics Data System (ADS)
Zong, Si-Guang; Liu, Tao; Cao, Jing; He, Qi-Yi
2018-02-01
How to solve the communication problem to the underwater target has turned into one of the subjects that the militarists of all over the world commonly concern. Laser-induced acoustic signal is a new approach for underwater acoustic source, which has much virtue such as high intensity, short pulse and broad frequency. The paper studies the opto-acoustic communication method. The acoustic signal characteristic of laser-induced breakdown is studied and corresponding theory model is systemically analyzed. The opto-acoustic communication experimental measure investigation is formed with the high power laser, water tank and high frequency hydrophone. The characteristic of acoustic signal is analyzed, such as intensity and frequency. This makes a stride for pursing the feasibility of laser-acoustic underwater communication.
Importance of punishment frequency in the Iowa gambling task: an fMRI study.
Ma, Shuangye; Zang, Yufeng; Cheung, Vinci; Chan, Chetwyn C H
2015-12-01
It has been widely found that in the Iowa Gambling Task (IGT; Bechara et al. Cognition, 50(1), 7-15 1994) normal subjects would gradually learn to prefer obtaining rewards for long-term benefits than seeking immediate rewards to maximize the overall profit. The current study aimed to gain an understanding of how punishment frequency in the IGT would be processed and its association with subjects' reward preferences. In this study, we employed the clinical version of the IGT, in which response options are not only different in the long-term outcome, but also associated with different punishment frequencies. Event-related functional Magnetic Resonance Imaging (fMRI) was used to capture the subjects' brain activity when performing the IGT. A total of 24 male subjects (mean age = 21.7 years, SD = 1.8 years), who were university students, participated in the experiment. It is found that subjects learned to select more from the decks that were advantageous in the long-term, but they were more sensitive to the effect of long-term outcome under the condition of high punishment frequency. The corresponding brain activation showed that the Anterior Cingulate Cortex (ACC) had significantly higher activation during the disadvantageous choices than the advantageous choices. Such activity difference between the two conditions of long-term outcome was more prominent with high punishment frequency than low punishment frequency; and this brain activity difference was significantly correlated with the behavioral performance under the condition of high punishment frequency. The results suggested that only in the context with high punishment frequency, there would be increased neural activity in ACC when subjects intended to select from the disadvantageous choices so that these choices would be inhibited and advantageous choices would be selected.
Voltzenlogel, Virginie; Vignal, Jean-Pierre; Hirsch, Edouard; Manning, Liliann
2014-10-01
Seizure frequency, although considered as an important factor in memory impairment in mesial temporal epilepsy (mTLE), is mostly confounded with other clinical variables, making it unclear to what extent recurrent seizures actually interfere with memory. The present study focuses on the influence of seizure frequency, studied as a main variable, on anterograde and remote memory. Seventy-one patients with unilateral mTLE were divided into two subgroups, as a function of their seizure frequency (monthly versus weekly seizures). Other seizure-related variables were controlled, namely, lateralisation and type of lesion, age at onset, years of ongoing seizures, etiologic factors, and number of AED. A comprehensive neuropsychological examination, including anterograde memory (verbal and non verbal recognition memory and free recall) tasks together with a large range of tests exploring different domains of remote memory, was carried out. Despite similar results on IQ, executive functions and attention, the low seizure-frequency group performed significantly better than the high seizure-frequency group on anterograde memory tests. Loss of autobiographical episodes and public-events memory, concomitant with spared personal semantic knowledge, was observed in both patient groups compared with healthy subjects. A worsening effect of high seizure frequency was recorded for autobiographical incidents and news-events memory, but unexpectedly, not for memory for famous people. The study of seizure frequency as the main variable leads us to suggest that high seizure frequency, itself, potentiates the effects of mesial temporal lobe damage on episodic memory deficits. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Rohr, Michaela; Wentura, Dirk
2014-10-01
High and low spatial frequency information has been shown to contribute differently to the processing of emotional information. In three priming studies using spatial frequency filtered emotional face primes, emotional face targets, and an emotion categorization task, we investigated this issue further. Differences in the pattern of results between short and masked, and short and long unmasked presentation conditions emerged. Given long and unmasked prime presentation, high and low frequency primes triggered emotion-specific priming effects. Given brief and masked prime presentation in Experiment 2, we found a dissociation: High frequency primes caused a valence priming effect, whereas low frequency primes yielded a differentiation between low and high arousing information within the negative domain. Brief and unmasked prime presentation in Experiment 3 revealed that subliminal processing of primes was responsible for the pattern observed in Experiment 2. The implications of these findings for theories of early emotional information processing are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.
1982-01-01
Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.
NASA Astrophysics Data System (ADS)
Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.
Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.
High-frequency self-aligned graphene transistors with transferred gate stacks.
Cheng, Rui; Bai, Jingwei; Liao, Lei; Zhou, Hailong; Chen, Yu; Liu, Lixin; Lin, Yung-Chen; Jiang, Shan; Huang, Yu; Duan, Xiangfeng
2012-07-17
Graphene has attracted enormous attention for radio-frequency transistor applications because of its exceptional high carrier mobility, high carrier saturation velocity, and large critical current density. Herein we report a new approach for the scalable fabrication of high-performance graphene transistors with transferred gate stacks. Specifically, arrays of gate stacks are first patterned on a sacrificial substrate, and then transferred onto arbitrary substrates with graphene on top. A self-aligned process, enabled by the unique structure of the transferred gate stacks, is then used to position precisely the source and drain electrodes with minimized access resistance or parasitic capacitance. This process has therefore enabled scalable fabrication of self-aligned graphene transistors with unprecedented performance including a record-high cutoff frequency up to 427 GHz. Our study defines a unique pathway to large-scale fabrication of high-performance graphene transistors, and holds significant potential for future application of graphene-based devices in ultra-high-frequency circuits.
Electricity resonance-induced fast transport of water through nanochannels.
Kou, Jianlong; Lu, Hangjun; Wu, Fengmin; Fan, Jintu; Yao, Jun
2014-09-10
We performed molecular dynamics simulations to study water permeation through a single-walled carbon nanotube with electrical interference. It was found that the water net flux across the nanochannel is greatly affected by the external electrical interference, with the maximal net flux occurred at an electrical interference frequency of 16670 GHz being about nine times as high as the net flux at the low or high frequency range of (<1000 GHz or >80,000 GHz). The above phenomena can be attributed to the breakage of hydrogen bonds as the electrical interference frequency approaches to the inherent resonant frequency of hydrogen bonds. The new mechanism of regulating water flux across nanochannels revealed in this study provides an insight into the water transportation through biological water channels and has tremendous potential in the design of high-flux nanofluidic systems.
Respiratory Control in Stuttering Speakers: Evidence from Respiratory High-Frequency Oscillations.
ERIC Educational Resources Information Center
Denny, Margaret; Smith, Anne
2000-01-01
This study examined whether stuttering speakers (N=10) differed from fluent speakers in relations between the neural control systems for speech and life support. It concluded that in some stuttering speakers the relations between respiratory controllers are atypical, but that high participation by the high frequency oscillation-producing circuitry…
High Frequency Plasma Generators for Ion Thrusters
NASA Technical Reports Server (NTRS)
Divergilio, W. F.; Goede, H.; Fosnight, V. V.
1981-01-01
The results of a one year program to experimentally adapt two new types of high frequency plasma generators to Argon ion thrusters and to analytically study a third high frequency source concept are presented. Conventional 30 cm two grid ion extraction was utilized or proposed for all three sources. The two plasma generating methods selected for experimental study were a radio frequency induction (RFI) source, operating at about 1 MHz, and an electron cyclotron heated (ECH) plasma source operating at about 5 GHz. Both sources utilize multi-linecusp permanent magnet configurations for plasma confinement. The plasma characteristics, plasma loading of the rf antenna, and the rf frequency dependence of source efficiency and antenna circuit efficiency are described for the RFI Multi-cusp source. In a series of tests of this source at Lewis Research Center, minimum discharge losses of 220+/-10 eV/ion were obtained with propellant utilization of .45 at a beam current of 3 amperes. Possible improvement modifications are discussed.
The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.
Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M
2016-09-01
One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Ross, Zev; Kheirbek, Iyad; Clougherty, Jane E; Ito, Kazuhiko; Matte, Thomas; Markowitz, Steven; Eisl, Holger
2011-11-01
Epidemiological studies have linked both noise and air pollution to common adverse health outcomes such as increased blood pressure and myocardial infarction. In urban settings, noise and air pollution share important sources, notably traffic, and several recent studies have shown spatial correlations between noise and air pollution. The temporal association between these exposures, however, has yet to be thoroughly investigated despite the importance of time series studies in air pollution epidemiology and the potential that correlations between these exposures could at least partly confound statistical associations identified in these studies. An aethelometer, for continuous elemental carbon measurement, was co-located with a continuous noise monitor near a major urban highway in New York City for six days in August 2009. Hourly elemental carbon measurements and hourly data on overall noise levels and low, medium and high frequency noise levels were collected. Hourly average concentrations of fine particles and nitrogen oxides, wind speed and direction and car, truck and bus traffic were obtained from nearby regulatory monitors. Overall temporal patterns, as well as day-night and weekday-weekend patterns, were characterized and compared for all variables. Noise levels were correlated with car, truck, and bus traffic and with air pollutants. We observed strong day-night and weekday-weekend variation in noise and air pollutants and correlations between pollutants varied by noise frequency. Medium and high frequency noise were generally more strongly correlated with traffic and traffic-related pollutants than low frequency noise and the correlation with medium and high frequency noise was generally stronger at night. Correlations with nighttime high frequency noise were particularly high for car traffic (Spearman rho=0.84), nitric oxide (0.73) and nitrogen dioxide (0.83). Wind speed and direction mediated relationships between pollutants and noise. Noise levels are temporally correlated with traffic and combustion pollutants and correlations are modified by the time of day, noise frequency and wind. Our results underscore the potential importance of assessing temporal variation in co-exposures to noise and air pollution in studies of the health effects of these urban pollutants. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kumagai, Hiroyuki; Pulido, Nelson; Fukuyama, Eiichi; Aoi, Shin
2013-01-01
investigate source processes of the 2011 Tohoku-Oki earthquake, we utilized a source location method using high-frequency (5-10 Hz) seismic amplitudes. In this method, we assumed far-field isotropic radiation of S waves, and conducted a spatial grid search to find the best fitting source locations along the subducted slab in each successive time window. Our application of the method to the Tohoku-Oki earthquake resulted in artifact source locations at shallow depths near the trench caused by limited station coverage and noise effects. We then assumed various source node distributions along the plate, and found that the observed seismograms were most reasonably explained when assuming deep source nodes. This result suggests that the high-frequency seismic waves were radiated at deeper depths during the earthquake, a feature which is consistent with results obtained from teleseismic back-projection and strong-motion source model studies. We identified three high-frequency subevents, and compared them with the moment-rate function estimated from low-frequency seismograms. Our comparison indicated that no significant moment release occurred during the first high-frequency subevent and the largest moment-release pulse occurred almost simultaneously with the second high-frequency subevent. We speculated that the initial slow rupture propagated bilaterally from the hypocenter toward the land and trench. The landward subshear rupture propagation consisted of three successive high-frequency subevents. The trenchward propagation ruptured the strong asperity and released the largest moment near the trench.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, Jin; Zhang, Yingchen; You, Shutang
Power grid primary frequency response will be significantly impaired by Photovoltaic (PV) penetration increase because of the decrease in inertia and governor response. PV inertia and governor emulation requires reserving PV output and leads to solar energy waste. This paper exploits current grid resources and explores energy storage for primary frequency response under high PV penetration at the interconnection level. Based on the actual models of the U.S. Eastern Interconnection grid and the Texas grid, effects of multiple factors associated with primary frequency response, including the governor ratio, governor deadband, droop rate, fast load response. are assessed under high PVmore » penetration scenarios. In addition, performance of batteries and supercapacitors using different control strategies is studied in the two interconnections. The paper quantifies the potential of various resources to improve interconnection-level primary frequency response under high PV penetration without curtailing solar output.« less
High-frequency profile in adolescents and its relationship with the use of personal stereo devices.
Silvestre, Renata Almeida Araújo; Ribas, Ângela; Hammerschmidt, Rogério; de Lacerda, Adriana Bender Moreira
2016-01-01
To analyze and correlate the audiometric findings of high frequencies (9-16 kHz) in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc.) and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Providing wireless bandwidth for high-speed rail operations : final report.
DOT National Transportation Integrated Search
2016-07-01
This project examined the possibility of providing wireless communication for train control systems on American high-speed trains. In this : study, the key issue is that the frequencies allocated for rail operations in the U.S. and the frequencies us...
NASA Astrophysics Data System (ADS)
Shaikh, Shahid Ali; Tian, Gang; Shi, Zhanjie; Zhao, Wenke; Junejo, S. A.
2018-02-01
Ground penetrating Radar (GPR) is an efficient tool for subsurface geophysical investigations, particularly at shallow depths. The non-destructiveness, cost efficiency, and data reliability are the important factors that make it an ideal tool for the shallow subsurface investigations. Present study encompasses; variations in central frequency of transmitting and receiving GPR antennas (Tx-Rx) have been analyzed and frequency band adjustment match filters are fabricated and tested accordingly. Normally, the frequency of both the antennas remains similar to each other whereas in this study we have experimentally changed the frequencies of Tx-Rx and deduce the response. Instead of normally adopted three pairs, a total of nine Tx-Rx pairs were made from 50 MHz, 100 MHz, and 200 MHz antennas. The experimental data was acquired at the designated near surface geophysics test site of the Zhejiang University, Hangzhou, China. After the impulse response analysis of acquired data through conventional as well as varied Tx-Rx pairs, different swap effects were observed. The frequency band and exploration depth are influenced by transmitting frequencies rather than the receiving frequencies. The impact of receiving frequencies was noticed on the resolution; the more noises were observed using the combination of high frequency transmitting with respect to low frequency receiving. On the basis of above said variable results we have fabricated two frequency band adjustment match filters, the constant frequency transmitting (CFT) and the variable frequency transmitting (VFT) frequency band adjustment match filters. By the principle, the lower and higher frequency components were matched and then incorporated with intermediate one. Therefore, this study reveals that a Tx-Rx combination of low frequency transmitting with high frequency receiving is a better choice. Moreover, both the filters provide better radargram than raw one, the result of VFT frequency band adjustment filter is much better than CFT frequency band adjustment filter.
Li, Wei; Kong, Li-hong; Wang, Hui; Shen, Feng; Wang, Ya-wen; Zhou, Hua; Sun, Guo-jie
2016-01-01
The frequency range of electroacupuncture in treatment of Alzheimer's disease in rats is commonly 2–5 Hz (low frequency) and 50–100 Hz (high frequency). We established a rat model of Alzheimer's disease by injecting β-amyloid 1–42 (Aβ1–42) into the bilateral hippocampal dentate gyrus to verify which frequency may be better suited in treatment. Electroacupuncture at 2 Hz or 50 Hz was used to stimulate Baihui (DU20) and Shenshu (BL23) acupoints. The water maze test and electrophysiological studies demonstrated that spatial memory ability was apparently improved, and the ranges of long-term potentiation and long-term depression were increased in Alzheimer's disease rats after electroacupuncture treatment. Moreover, the effects of electroacupuncture at 50 Hz were better than that at 2 Hz. These findings suggest that high-frequency electroacupuncture may enhance hippocampal synaptic transmission and potentially improve memory disorders in Alzheimer's disease rats. PMID:27335565
Observation of frequency cutoff for self-excited dust acoustic waves
NASA Astrophysics Data System (ADS)
Nosenko, V.; Zhdanov, S. K.; Morfill, G. E.; Kim, S.-H.; Heinrich, J.; Merlino, R. L.
2009-11-01
Complex (dusty) plasmas consist of fine solid particles suspended in a weakly ionized gas. Complex plasmas are excellent model systems to study wave phenomena down to the level of individual ``atoms''. Spontaneously excited dust acoustic waves were observed with high temporal resolution in a suspension of micron-size kaolin particles in a dc discharge in argon. Wave activity was found at frequencies as high as 400 Hz. At high wave numbers, the wave dispersion relation was acoustic-like (frequency proportional to wave number). At low wave numbers, the wave frequency did not tend to zero, but reached a cutoff frequency fc instead. The value of fc declined with distance from the anode. We propose a simple model that explains the observed cutoff by particle confinement in plasma. The existence of a cutoff frequency is very important for the propagation of waves: the waves excited above fc are propagating, and those below fc are evanescent.
Nonextensive statistics and skin depth of transverse wave in collisional plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashemzadeh, M., E-mail: hashemzade@gmail.com
Skin depth of transverse wave in a collisional plasma is studied taking into account the nonextensive electron distribution function. Considering the kinetic theory for charge particles and using the Bhatnagar-Gross-Krook collision model, a generalized transverse dielectric permittivity is obtained. The transverse dispersion relation in different frequency ranges is investigated. Obtaining the imaginary part of the wave vector from the dispersion relation, the skin depth for these frequency ranges is also achieved. Profiles of the skin depth show that by increasing the q parameter, the penetration depth decreases. In addition, the skin depth increases by increasing the electron temperature. Finally, itmore » is found that in the high frequency range and high electron temperature, the penetration depth decreases by increasing the collision frequency. In contrast, by increasing the collision frequency in a highly collisional frequency range, the skin depth of transverse wave increases.« less
Multi-Tone Millimeter-Wave Frequency Synthesizer for Atmospheric Propagation Studies
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Wintucky, Edwin G.
2014-01-01
The design and test results of a multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator is presented. The intended applications of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at Q-band (37 to 43 GHz). These studies would enable the design of robust high data rate space-to-ground satellite communication links.
Multi-Tone Millimeter-Wave Frequency Synthesizer for Atmospheric Propagation Studies
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Wintucky, Edwin G.
2014-01-01
This paper presents the design and test results of a multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at Q-band (37-43 GHz). These studies would enable the design of robust high data rate space-to-ground satellite communication links.
Multi-Tone Millimeter-Wave Frequency Synthesizer for Atmospheric Propagation Studies
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Wintucky, Edwin G.
2014-01-01
This paper presents the design and test results of a multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at Q-band (37 to 43 GHz). These studies would enable the design of robust high data rate space-to-ground satellite communication links.
Gender identification from high-pass filtered vowel segments: the use of high-frequency energy.
Donai, Jeremy J; Lass, Norman J
2015-10-01
The purpose of this study was to examine the use of high-frequency information for making gender identity judgments from high-pass filtered vowel segments produced by adult speakers. Specifically, the effect of removing lower-frequency spectral detail (i.e., F3 and below) from vowel segments via high-pass filtering was evaluated. Thirty listeners (ages 18-35) with normal hearing participated in the experiment. A within-subjects design was used to measure gender identification for six 250-ms vowel segments (/æ/, /ɪ /, /ɝ/, /ʌ/, /ɔ/, and /u/), produced by ten male and ten female speakers. The results of this experiment demonstrated that despite the removal of low-frequency spectral detail, the listeners were accurate in identifying speaker gender from the vowel segments, and did so with performance significantly above chance. The removal of low-frequency spectral detail reduced gender identification by approximately 16 % relative to unfiltered vowel segments. Classification results using linear discriminant function analyses followed the perceptual data, using spectral and temporal representations derived from the high-pass filtered segments. Cumulatively, these findings indicate that normal-hearing listeners are able to make accurate perceptual judgments regarding speaker gender from vowel segments with low-frequency spectral detail removed via high-pass filtering. Therefore, it is reasonable to suggest the presence of perceptual cues related to gender identity in the high-frequency region of naturally produced vowel signals. Implications of these findings and possible mechanisms for performing the gender identification task from high-pass filtered stimuli are discussed.
A study on thermal characteristics analysis model of high frequency switching transformer
NASA Astrophysics Data System (ADS)
Yoo, Jin-Hyung; Jung, Tae-Uk
2015-05-01
Recently, interest has been shown in research on the module-integrated converter (MIC) in small-scale photovoltaic (PV) generation. In an MIC, the voltage boosting high frequency transformer should be designed to be compact in size and have high efficiency. In response to the need to satisfy these requirements, this paper presents a coupled electromagnetic analysis model of a transformer connected with a high frequency switching DC-DC converter circuit while considering thermal characteristics due to the copper and core losses. A design optimization procedure for high efficiency is also presented using this design analysis method, and it is verified by the experimental result.
NASA Astrophysics Data System (ADS)
Ma, Weiwei; Wan, Xiuquan; Wang, Zhankun; Liu, Yulong; Wan, Kai
2017-12-01
The influence of high-frequency atmospheric forcing on the formation of a well-mixed summer warm water column in the central Bohai Sea is investigated comparing model simulations driven by daily surface forcing and those using monthly forcing data. In the absence of high-frequency atmospheric forcing, numerical simulations have repeatedly failed to reproduce this vertically uniform column of warm water measured over the past 35 years. However, high-frequency surface forcing is found to strongly influence the structure and distribution of the well-mixed warm water column, and simulations are in good agreement with observations. Results show that high frequency forcing enhances vertical mixing over the central bank, intensifies downward heat transport, and homogenizes the water column to form the Bohai central warm column. Evidence presented shows that high frequency forcing plays a dominant role in the formation of the well-mixed warm water column in summer, even without the effects of tidal and surface wave mixing. The present study thus provides a practical and rational way of further improving the performance of oceanic simulations in the Bohai Sea and can be used to adjust parameterization schemes of ocean models.
Comparison of High-Frequency Solar Irradiance: Ground Measured vs. Satellite-Derived
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lave, Matthew; Weekley, Andrew
2016-11-21
High-frequency solar variability is an important to grid integration studies, but ground measurements are scarce. The high resolution irradiance algorithm (HRIA) has the ability to produce 4-sceond resolution global horizontal irradiance (GHI) samples, at locations across North America. However, the HRIA has not been extensively validated. In this work, we evaluate the HRIA against a database of 10 high-frequency ground-based measurements of irradiance. The evaluation focuses on variability-based metrics. This results in a greater understanding of the errors in the HRIA as well as suggestions for improvement to the HRIA.
Vast Volatility Matrix Estimation using High Frequency Data for Portfolio Selection*
Fan, Jianqing; Li, Yingying; Yu, Ke
2012-01-01
Portfolio allocation with gross-exposure constraint is an effective method to increase the efficiency and stability of portfolios selection among a vast pool of assets, as demonstrated in Fan et al. (2011). The required high-dimensional volatility matrix can be estimated by using high frequency financial data. This enables us to better adapt to the local volatilities and local correlations among vast number of assets and to increase significantly the sample size for estimating the volatility matrix. This paper studies the volatility matrix estimation using high-dimensional high-frequency data from the perspective of portfolio selection. Specifically, we propose the use of “pairwise-refresh time” and “all-refresh time” methods based on the concept of “refresh time” proposed by Barndorff-Nielsen et al. (2008) for estimation of vast covariance matrix and compare their merits in the portfolio selection. We establish the concentration inequalities of the estimates, which guarantee desirable properties of the estimated volatility matrix in vast asset allocation with gross exposure constraints. Extensive numerical studies are made via carefully designed simulations. Comparing with the methods based on low frequency daily data, our methods can capture the most recent trend of the time varying volatility and correlation, hence provide more accurate guidance for the portfolio allocation in the next time period. The advantage of using high-frequency data is significant in our simulation and empirical studies, which consist of 50 simulated assets and 30 constituent stocks of Dow Jones Industrial Average index. PMID:23264708
Computer-Aided Design/Manufacturing (CAD/M) for High-Speed Interconnect.
1981-10-01
are frequency sensitive and hence lend themselves to frequency domain ananlysis . Most of the classical microwave analysis is handled in the frequency ...capability integrated into a time-domain analysis program. This approach allows determination of frequency -dependent transmission line (interconnect...the items to consider in any interconnect study is that of the frequency range of interest. This determines whether the interconnections must be treated
The effect of changing disk parameters on whirling frequency of high speed rotor system
NASA Astrophysics Data System (ADS)
Wahab, A. M. Abdul; Rasid, Z. A.; Abu, A.; Rudin, N. F. Mohd Noor; Yakub, F.
2017-12-01
The requirement for efficiency improvement of machines has caused machine rotor to be designed to rotate at high speeds. It is known that whirling natural frequency of a shaft changes with the change of shaft speed and the design needs to avoid points of resonance where the whirling frequency equals the shaft speed. At high speeds, a shaft may have to carry a huge torque along and this torsional effect has been neglected in past shaft analyses. Whirling behaviour of high speed rotating shaft is investigated in this study with consideration of the torsional effect of the shaft. The shaft system under study consists of a shaft, discs and two bearings, and the focus is on the effect of the disc parameters. A finite element formulation is developed based on Nelson’s 5 degrees of freedom (DOF) per node element that includes the torsional degree of freedom. Bolotin’s method is applied to the derived Mathieu-Hill type of equation to get quadratic eigenvalues problem that gives the forward and backward frequencies of the shaft. Campbell’s diagrams are drawn in studying the effect of discs on the whirling behaviour of the shaft. It is found that the addition of disks on the shaft decreases the whirling frequency of the shaft and the frequency is lower for mass located at the centre of the shaft compared to the one located near to the end. The effect of torsional motion is found to be significant where the difference between critical speed of 4DOF and 5DOF models can be as high as 15%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nio, S.D.; Yang, C.S.; Tewfik, N.
1993-09-01
A new development in the application of sequence stratigraphic concepts in marine as well as continental basins is the recognition of high-frequency cyclic patterns in rock successions in the subsurface. Studies of six wells from the northern, central, and southern parts of the Gulf of Suez show the presence of well-preserved, high-frequency cycles with periodicities similar to the orbitally forced Malankovitch parameters. Subsurface rock successions, third-order sequences, and high-frequency cycles were compared with outcrops. After establishing the biostratigraphic framework for the above-mentioned wells, a sequence analysis was performed. Sequence boundaries and maximum flooding positions in each well were calibrated withmore » the occurrences and evaluation of the high-frequency cycles. It became obvious that there is an intimate relationship between these high-frequency Milankovitch cycles and sequence organization. In addition, a close relationship can be observed in the subsurface as well as in outcrops between high-frequency climatic changes (connected to the Milankovitch cycles) and (litho)facies variability. Quantitative evaluations of each sequence and/or systems tract can be computed with the International Geoservices' cyclicity analysis tool (MILABAR). The results are summarized in a well composite chart, rate (NAR), and ratio of preserved time. In correlations between the wells, an accuracy of 500-100 Ka can be obtained. The quantitative evaluation of the sequence and high-frequency cycle analysis gave some new aspects concerning the (litho)facies and geodynamic development during the pre- as well as the synrift stages of the Gulf of Suez Basin.« less
NASA Astrophysics Data System (ADS)
Choi, Jae-Won; Cha, Yumi; Kim, Jeoung-Yun
2016-12-01
This study found that there is a significant negative correlation between summer drought in Korea, China and Japan and the frequency of tropical cyclone (TC) in the subtropical western North Pacific (SWNP) using effective drought index (EDI). The frequency of TCs that affect Korea is low (high) in a year of summer drought (non-drought). As a case study, in 1994 when there is extremely severe summer drought in Korea, there was high frequency of TCs while in 2003 when there was least severe summer drought, the frequency of TCs is the lowest. Changes in the anomalous secondary circulation, namely anomalous upward (downward) flow in the SWNP and anomalous downward (upward) flow in the mid-latitudes of East Asia, are one of the causes of drought (non-drought).
Towards a Reconceptualisation of "Word" for High Frequency Word Generation in Word Knowledge Studies
ERIC Educational Resources Information Center
Sibanda, Jabulani; Baxen, Jean
2014-01-01
The present paper derives from a PhD study investigating the nexus between Grade 4 textbook vocabulary demands and Grade 3 isiXhosa-speaking learners' knowledge of that vocabulary to enable them to read to learn in Grade 4. The paper challenges the efficacy of the four current definitions of "word" for generating high frequency words…
Alumina ceramic based high-temperature performance of wireless passive pressure sensor
NASA Astrophysics Data System (ADS)
Wang, Bo; Wu, Guozhu; Guo, Tao; Tan, Qiulin
2016-12-01
A wireless passive pressure sensor equivalent to inductive-capacitive (LC) resonance circuit and based on alumina ceramic is fabricated by using high temperature sintering ceramic and post-fire metallization processes. Cylindrical copper spiral reader antenna and insulation layer are designed to realize the wireless measurement for the sensor in high temperature environment. The high temperature performance of the sensor is analyzed and discussed by studying the phase-frequency and amplitude-frequency characteristics of reader antenna. The average frequency change of sensor is 0.68 kHz/°C when the temperature changes from 27°C to 700°C and the relative change of twice measurements is 2.12%, with high characteristic of repeatability. The study of temperature-drift characteristic of pressure sensor in high temperature environment lays a good basis for the temperature compensation methods and insures the pressure signal readout accurately.
Joury, Easter; Khairallah, May; Sabbah, Wael; Elias, Kanaan; Bedi, Raman
2016-09-08
High frequency of free sugars intake, during the first year of life is probably the greatest risk factor for early childhood caries. The latter is a global public health challenge. Very little is known about the social determinants of infant's frequency of free sugars intake, particularly in low-income countries. Thus, the present study aimed to assess the association between the frequency of free sugars intake among 1-year-old Syrian infants and each of parents' socioeconomic position (SEP), maternal frequency of free sugars intake and knowledge of infant's oral health behaviour. Using a cross-sectional design, 323 1-year-old infants, attending vaccination clinics in 3 maternal and child health centres (MCHCs) in Damascus, Syria, were selected. A systematic random sampling was applied using the MCHCs' monthly vaccination registries. The 3 MCHCs were located in affluent, moderate and deprived areas. Infants' mothers completed a structured questionnaire on socio-demographics, infant's and mother's frequency of free sugars intake from cariogenic foods and beverages, and mother's knowledge about infant's oral health behaviour. Binary and multiple regression analyses were performed. The level of significance was set at 5 %. The response rate was 100 %. Overall, 42.7 % of infants had high frequency of free sugars intake (>4times a day). Infants whose fathers were not working were more likely to have high frequency of free sugars intake. Similarly, infants whose mothers had low level of knowledge about infant's oral health behaviour, or high frequency of free sugars intake were more likely to have high frequency of free sugars intake. The association between father's occupation and infant's frequency of free sugars intake attenuated after adjustment for mother's knowledge and frequency of free sugars intake (adjusted OR = 1.5, 1.8, 3.2; 95%CI = 0.5-4.8, 1.1-3, 1.4-7.4; respectively). There are socioeconomic inequalities in the frequency of free sugars intake among Syrian 1-year-old infants. Integrated pre/post-natal interventions, targeting mothers from low SEP and aiming at reducing their free sugars intake and improving their knowledge about infant's oral health behaviour, will potentially reduce socioeconomic inequalities in infant's frequency of free sugars intake.
Silveira, Vladímir de Aquino; Souza, Givago da Silva; Gomes, Bruno Duarte; Rodrigues, Anderson Raiol; Silveira, Luiz Carlos de Lima
2014-01-01
We used psychometric functions to estimate the joint entropy for space discrimination and spatial frequency discrimination. Space discrimination was taken as discrimination of spatial extent. Seven subjects were tested. Gábor functions comprising unidimensionalsinusoidal gratings (0.4, 2, and 10 cpd) and bidimensionalGaussian envelopes (1°) were used as reference stimuli. The experiment comprised the comparison between reference and test stimulithat differed in grating's spatial frequency or envelope's standard deviation. We tested 21 different envelope's standard deviations around the reference standard deviation to study spatial extent discrimination and 19 different grating's spatial frequencies around the reference spatial frequency to study spatial frequency discrimination. Two series of psychometric functions were obtained for 2%, 5%, 10%, and 100% stimulus contrast. The psychometric function data points for spatial extent discrimination or spatial frequency discrimination were fitted with Gaussian functions using the least square method, and the spatial extent and spatial frequency entropies were estimated from the standard deviation of these Gaussian functions. Then, joint entropy was obtained by multiplying the square root of space extent entropy times the spatial frequency entropy. We compared our results to the theoretical minimum for unidimensional Gábor functions, 1/4π or 0.0796. At low and intermediate spatial frequencies and high contrasts, joint entropy reached levels below the theoretical minimum, suggesting non-linear interactions between two or more visual mechanisms. We concluded that non-linear interactions of visual pathways, such as the M and P pathways, could explain joint entropy values below the theoretical minimum at low and intermediate spatial frequencies and high contrasts. These non-linear interactions might be at work at intermediate and high contrasts at all spatial frequencies once there was a substantial decrease in joint entropy for these stimulus conditions when contrast was raised. PMID:24466158
Silveira, Vladímir de Aquino; Souza, Givago da Silva; Gomes, Bruno Duarte; Rodrigues, Anderson Raiol; Silveira, Luiz Carlos de Lima
2014-01-01
We used psychometric functions to estimate the joint entropy for space discrimination and spatial frequency discrimination. Space discrimination was taken as discrimination of spatial extent. Seven subjects were tested. Gábor functions comprising unidimensionalsinusoidal gratings (0.4, 2, and 10 cpd) and bidimensionalGaussian envelopes (1°) were used as reference stimuli. The experiment comprised the comparison between reference and test stimulithat differed in grating's spatial frequency or envelope's standard deviation. We tested 21 different envelope's standard deviations around the reference standard deviation to study spatial extent discrimination and 19 different grating's spatial frequencies around the reference spatial frequency to study spatial frequency discrimination. Two series of psychometric functions were obtained for 2%, 5%, 10%, and 100% stimulus contrast. The psychometric function data points for spatial extent discrimination or spatial frequency discrimination were fitted with Gaussian functions using the least square method, and the spatial extent and spatial frequency entropies were estimated from the standard deviation of these Gaussian functions. Then, joint entropy was obtained by multiplying the square root of space extent entropy times the spatial frequency entropy. We compared our results to the theoretical minimum for unidimensional Gábor functions, 1/4π or 0.0796. At low and intermediate spatial frequencies and high contrasts, joint entropy reached levels below the theoretical minimum, suggesting non-linear interactions between two or more visual mechanisms. We concluded that non-linear interactions of visual pathways, such as the M and P pathways, could explain joint entropy values below the theoretical minimum at low and intermediate spatial frequencies and high contrasts. These non-linear interactions might be at work at intermediate and high contrasts at all spatial frequencies once there was a substantial decrease in joint entropy for these stimulus conditions when contrast was raised.
A Hierarchy of "Confusable" High-Frequency Words in Isolation and Context.
ERIC Educational Resources Information Center
Krieger, Veronica K.
1981-01-01
The study assessed the degree to which two sets of disabled readers (17 clinic students with a mean CA of 9 years and 13 fourth-grade disabled readers) commonly and identically confuse high frequency sight words in isolation and context. (Author/CL)
MacKenzie, Michael J; Nicklas, Eric; Brooks-Gunn, Jeanne; Waldfogel, Jane
2014-12-01
This study used the Fragile Families and Child Well-Being Study to examine the effects of repeated exposure to harsh parenting on child externalizing behavior across the first decade of life, and a moderating role for cumulative ecological risk. Maternal report of harsh parenting, defined as high frequency spanking, was assessed at age 1, 3, 5, and 9, along with child externalizing at age 9 (N=2,768). Controlling for gender, race, maternal nativity, and city of residence, we found a cumulative risk index to significantly moderate the effects of repeated harsh parenting on child behavior, with the effects of repeated high-frequency spanking being amplified for those experiencing greater levels of cumulative risk. Harsh parenting, in the form of high frequency spanking, remains a too common experience for children, and results demonstrate that the effects of repeated exposure to harsh parenting across the first decade are amplified for those children already facing the most burden. Copyright © 2014. Published by Elsevier Ltd.
MacKenzie, Michael J.; Nicklas, Eric; Brooks-Gunn, Jeanne; Waldfogel, Jane
2016-01-01
This study used the Fragile Families and Child Well-being study to examine the effects of repeated exposure to harsh parenting on child externalizing behavior across the first decade of life, and a moderating role for cumulative ecological risk. Maternal report of harsh parenting, defined as high frequency spanking, was assessed at age 1, 3, 5, and 9, along with child externalizing at age 9 (N=2768). Controlling for gender, race, maternal nativity, and city of residence, we found a cumulative risk index to significantly moderate the effects of repeated harsh parenting on child behavior, with the effects of repeated high-frequency spanking being amplified for those experiencing greater levels of cumulative risk. Harsh parenting, in the form of high frequency spanking, remains a too common experience for children, and results demonstrate that the effects of repeated exposure to harsh parenting across the first decade are amplified for those children already facing the most burden. PMID:25465318
Local regression type methods applied to the study of geophysics and high frequency financial data
NASA Astrophysics Data System (ADS)
Mariani, M. C.; Basu, K.
2014-09-01
In this work we applied locally weighted scatterplot smoothing techniques (Lowess/Loess) to Geophysical and high frequency financial data. We first analyze and apply this technique to the California earthquake geological data. A spatial analysis was performed to show that the estimation of the earthquake magnitude at a fixed location is very accurate up to the relative error of 0.01%. We also applied the same method to a high frequency data set arising in the financial sector and obtained similar satisfactory results. The application of this approach to the two different data sets demonstrates that the overall method is accurate and efficient, and the Lowess approach is much more desirable than the Loess method. The previous works studied the time series analysis; in this paper our local regression models perform a spatial analysis for the geophysics data providing different information. For the high frequency data, our models estimate the curve of best fit where data are dependent on time.
Pattinson, Julie; Parke, Adrian
2017-01-01
The prevalence of older adult female gambling participation and gambling disorder is increasing in the UK, and there is a paucity of published research available to understand possible risk factors for frequent gambling in this demographic. The aim of the current study was to identify and explore motivations and patterns of gambling behavior in high-frequency older adult female gamblers in the UK, from the perspective of the individual and in the context of their experience of aging. Ten UK older adult female high-frequency gamblers were recruited via stratified purposive sampling, with a mean age of 70.4 years. Data was collected via semistructured interviews and analyzed using interpretative phenomenological analysis. Three core themes representative of the experience of this phenomenon emerged from the transcripts, including: Filling voids, emotional escape, and overspending. The present study has provided a contextualized understanding of motivating factors and several age-related vulnerabilities that may account for high gambling frequency in this population.
Radhakrishnan, Rajan; King, Ellen W.; Dickman, Janelle K.; Herold, Carli A.; Johnston, Natalie F.; Spurgin, Megan L.; Sluka, Kathleen A.
2009-01-01
Transcutaneous electrical nerve stimulation (TENS) is a form of non-pharmacological treatment for pain. Involvement of descending inhibitory systems is implicated in TENS-induced analgesia. In the present study, the roles of spinal 5-HT and α2-adrenoceptors in TENS analgesia were investigated in rats. Hyperalgesia was induced by inflaming the knee joint with 3% kaolin—carrageenan mixture and assessed by measuring paw withdrawal latency (PWL) to heat before and 4 h after injection. The (1) α2-adrenergic antagonist yohimbine (30 μg), (2) 5-HT antagonist methysergide (5-HT1 and 5-HT2,30 μg), one of the 5-HT receptor subtype antagonists, (3) NAN-190 (5-HT1A, 15 μg), (4) ketanserin (5-HT2A, 30 μg), (5) MDL-72222 (5-HT3, 12 μg), or (6) vehicle was administered intrathecally prior to TENS treatment. Low (4 Hz) or high (100 Hz) frequency TENS at sensory intensity was then applied to the inflamed knee for 20 min and PWL was determined. Selectivity of the antagonists used was confirmed using respective agonists administered intrathecally. Yohimbine had no effect on the antihyperalgesia produced by low or high frequency TENS. Methysergide and MDL-72222 prevented the antihyperalgesia produced by low, but not high, frequency TENS. Ketanserin attenuated the antihyperalgesic effects of low frequency TENS whereas NAN-190 had no effect. The results from the present study show that spinal 5-HT receptors mediate low, but not high, frequency TENS-induced antihyperalgesia through activation of 5-HT2A and 5-HT3 receptors in rats. Furthermore, spinal noradrenergic receptors are not involved in either low or high frequency TENS antihyperalgesia. PMID:14499437
Kawashima, Takayuki; Sato, Takao
2012-01-01
When a second sound follows a long first sound, its location appears to be perceived away from the first one (the localization/lateralization aftereffect). This aftereffect has often been considered to reflect an efficient neural coding of sound locations in the auditory system. To understand determinants of the localization aftereffect, the current study examined whether it is induced by an interaural temporal difference (ITD) in the amplitude envelope of high frequency transposed tones (over 2 kHz), which is known to function as a sound localization cue. In Experiment 1, participants were required to adjust the position of a pointer to the perceived location of test stimuli before and after adaptation. Test and adapter stimuli were amplitude modulated (AM) sounds presented at high frequencies and their positional differences were manipulated solely by the envelope ITD. Results showed that the adapter's ITD systematically affected the perceived position of test sounds to the directions expected from the localization/lateralization aftereffect when the adapter was presented at ±600 µs ITD; a corresponding significant effect was not observed for a 0 µs ITD adapter. In Experiment 2, the observed adapter effect was confirmed using a forced-choice task. It was also found that adaptation to the AM sounds at high frequencies did not significantly change the perceived position of pure-tone test stimuli in the low frequency region (128 and 256 Hz). The findings in the current study indicate that ITD in the envelope at high frequencies induces the localization aftereffect. This suggests that ITD in the high frequency region is involved in adaptive plasticity of auditory localization processing.
NASA Astrophysics Data System (ADS)
Mahajan, Sandeep; Haridas, Divya; Ali, S. T.; Munirathnam, N. R.; Sreenivas, K.; Thakur, O. P.; Prakash, Chandra
2014-10-01
In present study we have prepared ferroelectric BaZrxTi1-xO3 (x=0.05) ceramic by conventional solid state reaction route and studied its electrical properties as a function of temperature and frequency. X-ray diffraction (XRD) analysis shows single-phase formation of the compound with orthorhombic crystal structure at room temperature. Impedance and electric modulus spectroscopy analysis in the frequency range of 40 Hz-1 MHz at high temperature (200-600 °C) suggests two relaxation processes with different time constant are involved which are attributed to bulk and grain boundary effects. Frequency dependent dielectric plot at different temperature shows normal variation with frequency while dielectric loss (tanδ) peak was found to obey an Arrhenius law with activation energy of 1.02 eV. The frequency-dependent AC conductivity data were also analyzed in a wide temperature range. In present work we have studied the role of grain and grain boundaries on the electrical behaviour of Zr-doped BaTiO3 and their dependence on temperature and frequency by complex impedance and modulus spectroscopy (CIS) technique in a wide frequency (40 Hz-1 MHz) and high temperature range.
Smith, G Troy
2006-01-01
The neural circuit that controls the electric organ discharge (EOD) of the brown ghost knifefish (Apteronotus leptorhynchus) contains two spontaneous oscillators. Both pacemaker neurons in the medulla and electromotor neurons (EMNs) in the spinal cord fire spontaneously at frequencies of 500-1,000 Hz to control the EOD. These neurons continue to fire in vitro at frequencies that are highly correlated with in vivo EOD frequency. Previous studies used channel blocking drugs to pharmacologically characterize ionic currents that control high-frequency firing in pacemaker neurons. The goal of the present study was to use similar techniques to investigate ionic currents in EMNs, the other type of spontaneously active neuron in the electromotor circuit. As in pacemaker neurons, high-frequency firing of EMNs was regulated primarily by tetrodotoxin-sensitive sodium currents and by potassium currents that were sensitive to 4-aminopyridine and kappaA-conotoxin SIVA, but resistant to tetraethylammonium. EMNs, however, differed from pacemaker neurons in their sensitivity to some channel blocking drugs. Alpha-dendrotoxin, which blocks a subset of Kv1 potassium channels, increased firing rates in EMNs, but not pacemaker neurons; and the sodium channel blocker muO-conotoxin MrVIA, which reduced firing rates of pacemaker neurons, had no effect on EMNs. These results suggest that similar, but not identical, ionic currents regulate high-frequency firing in EMNs and pacemaker neurons. The differences in the ionic currents expressed in pacemaker neurons and EMNs might be related to differences in the morphology, connectivity, or function of these two cell types.
Zarei, Ali Asghar; Foroutan, Seyyed Abbas; Foroutan, Seyyed Mohsen; Erfanian Omidvar, Abbas
2011-01-01
Pyridostigmine bromide (PB) is a reversible cholinesterase inhibitor. The aim of this study was to determine the effect of orally administration of single dose sustained-released tablet of pyridostigmine bromide (PBSR) on the frequency domain indices of heart rate variability (HRV). Thirty-two healthy young men were participated in this study. They were divided into 2 groups; the pyridostigmine group (n = 22) and the placebo group (n = 10). Electrocardiogram (ECG) was recorded at 10, 30, 60, 90, 120, 150, 180, 210, 240, 300 and 420 min after PBSR administration. At each time, simultaneously, a blood sample was prepared and PB plasma concentration was measured by high-performance liquid chromatography (HPLC) method. Statistical analysis showed that in different indices of HRV, there is a significant increase in low frequency (LF) band at 300 min, but no difference in high frequency band (HF). It also showed significant decreases in normalized high frequency band (Hfnu), normalized low frequency band (Lfnu) and LF/HF ratio at 120, 240 and 300 min after PBSR administration. Maximum plasma concentration of PB was 150 min after the administration. In conclusion, administration of a single dose PBSR can enhance the frequency domains indices of HRV and improvesympathovagal balance. PMID:24250427
Parametric Testing of Chevrons on Single Flow Hot Jets
NASA Technical Reports Server (NTRS)
Bridges, James; Brown, Clifford A.
2004-01-01
A parametric family of chevron nozzles have been studied, looking for relationships between chevron geometric parameters, flow characteristics, and far-field noise. Both cold and hot conditions have been run at acoustic Mach number 0.9. Ten models have been tested, varying chevron count, penetration, length, and chevron symmetry. Four comparative studies were defined from these datasets which show: that chevron length is not a major impact on either flow or sound; that chevron penetration increases noise at high frequency and lowers it at low frequency, especially for low chevron counts; that chevron count is a strong player with good low frequency reductions being achieved with high chevron count without strong high frequency penalty; and that chevron asymmetry slightly reduces the impact of the chevron. Finally, it is shown that although the hot jets differ systematically from the cold one, the overall trends with chevron parameters is the same.
Influence of mixing and ultrasound frequency on antisolvent crystallisation of sodium chloride.
Lee, Judy; Ashokkumar, Muthupandian; Kentish, Sandra E
2014-01-01
Ultrasound is known to promote nucleation of crystals and produce a narrower size distribution in a controlled and reproducible manner for the crystallisation process. Although there are various theories that suggest cavitation bubbles are responsible for sonocrystallisation, most studies use power ultrasonic horns that generate both intense shear and cavitation and this can mask the role that cavitation bubbles play. High frequency ultrasound from a plate transducer can be used to examine the effect of cavitation bubbles without the intense shear effect. This study reports the crystal size and morphology with various mixing speeds and ultrasound frequencies. The results show high frequency ultrasound produced sodium chloride crystals of similar size distribution as an ultrasonic horn. In addition, ultrasound generated sodium chloride crystals having a more symmetrical cubic structure compared to crystals produced by a high shear mixer. Copyright © 2013 Elsevier B.V. All rights reserved.
Heat-power working regimes of a high-frequency (0.44 MHz) 1000-kW induction plasmatron
NASA Astrophysics Data System (ADS)
Gorbanenko, V. M.; Farnasov, G. A.; Lisafin, A. B.
2015-12-01
The energy working regimes of a superpower high-frequency induction (HFI) plasmatron with a high-frequency (HF) generator are studied. The HFI plasmatron with a power of 1000 kVA and a working frequency of 440 kHz, in which air is used as a plasma-forming gas, can be used for treatment of various oxide powder materials. The energy regimes substantially influence finish products and their costs. Various working regimes of the HFI plasma unit and the following characteristics are studied: the dependence of the vibration power on the anode power, the dependence of the power losses on the anode power at various of plasma-forming gas flow rates, and the coefficients of efficiency of the plasmatron and the HFI-plasma unit at various powers. The effect of the plasma-forming gas flow rate on the bulk temperature is determined.
RF Design of a High Average Beam-Power SRF Electron Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sipahi, Nihan; Biedron, Sandra; Gonin, Ivan
2016-06-01
There is a significant interest in developing high-average power electron sources, particularly in the area of electron sources integrated with Superconducting Radio Frequency (SRF) systems. For these systems, the electron gun and cathode parts are critical components for stable intensity and high-average powers. In this initial design study, we will present the design of a 9-cell accelerator cavity having a frequency of 1.3 GHz and the corresponding field optimization studies.
Martínez-Rivera, Freddyson J; Rodriguez-Romaguera, Jose; Lloret-Torres, Mario E; Do Monte, Fabricio H; Quirk, Gregory J; Barreto-Estrada, Jennifer L
2016-11-01
Recent research in humans and rodents has explored the use of deep brain stimulation (DBS) of the ventral capsule/ventral striatum (VS) as a possible treatment for drug addiction. However, the optimum electrode placement and optimum DBS parameters have not been thoroughly studied. Here we varied stimulation sites and frequencies to determine whether DBS of the VS could facilitate the extinction of morphine-induced conditioned place preference in rats. Rats were implanted with DBS electrodes in the dorsal or ventral subregions of the VS and trained to the morphine conditioned place preference. Subsequently, rats received extinction sessions over 9 days, combined with 60 min of either high- (130 Hz) or low- (20 Hz) frequency DBS. To study circuit-wide activations after DBS of the VS, c-fos immunohistochemistry was performed in regions involved in the extinction of drug-seeking behaviors. High-frequency DBS of the dorsal-VS impaired both extinction training and extinction memory, whereas high-frequency DBS of the ventral-VS had no effect. In contrast, low-frequency DBS of the dorsal-VS strengthened extinction memory when tested 2 or 9 days after the cessation of stimulation. Both DBS frequencies increased c-fos expression in the infralimbic prefrontal cortex, but only low-frequency DBS increased c-fos expression in the basal amygdala and the medial portion of the central amygdala. Our results suggest that low-frequency (rather than high-frequency) DBS of the dorsal-VS strengthens extinction memory and may be a potential adjunct for extinction-based therapies for treatment-refractory opioid addiction. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Gao, Zaifeng; Bentin, Shlomo
2011-01-01
Face perception studies investigated how spatial frequencies (SF) are extracted from retinal display while forming a perceptual representation, or their selective use during task-imposed categorization. Here we focused on the order of encoding low-spatial frequencies (LSF) and high-spatial frequencies (HSF) from perceptual representations into…
Religion, Religious Heterogeneity, and Intimate Partner Violence Among Korean Immigrant Women.
Kim, Chunrye
2018-02-01
This study examined the role of religious affiliations and frequency of religious service attendance-such as church, Bible studies, and temples-as well as religious heterogeneity between couples on intimate partner violence (IPV) among Korean immigrant women in the United States. Through a case-control design, this study compared 64 Korean immigrant IPV victims with 63 Korean immigrant non-IPV victims. This study's findings reveal that for Korean immigrant women, a high frequency of religious service attendance was associated with higher IPV victimization, while their partners' high religious service attendance was associated with lower IPV victimization. When women's partners were religious compared with when they were not religious, they were less likely to perpetrate IPV even when the partners' alcohol consumption frequency increased. Also, when there was a gap between couples regarding frequency of religious attendance, IPV victimization increased. This discussion concludes by suggesting some policy implications based on these findings.
Korsak, A; Chaikovsky, Yu; Sokurenko, L; Likhodiievskyi, V; Neverovskyi, A
2016-02-01
A new experimental model for tissues connection at peripheral nerve injury site in form of tissues welding was designed. In current study we investigated motoneuron state 1, 3, 6 and 12 weeks after peripheral nerve injury and surgical repair with high-frequency electrosurgical technology. Spinal cord sections was stained by Nissl method and observed with light microscopy. We found that postoperative period in animals from experimental groups characterized by qualitative changes in neurons from spinal motor centers that can be interpreted as compensatory processes as response to alteration. In animals from group with high-frequency electrosurgical technology usage stabilization processes passes more quickly comparatively to animals with epineural sutures. High-frequency electrosurgical technology usage provides less harmful effects on motoneurons than epineural suturing.
NASA Astrophysics Data System (ADS)
Bandurkin, I. V.; Kaminsky, A. K.; Perelstein, E. A.; Peskov, N. Yu.; Savilov, A. V.; Sedykh, S. N.
2012-08-01
The possibility of using frequency multiplication in order to obtain high-power short-wavelength radiation from a free-electron maser (FEM) with a Bragg resonator has been studied. Preliminary experiments with an LIU-3000 (JINR) linear induction accelerator demonstrate the operation of a frequency-multiplying FEM at megawatt power in the 6- and 4-mm wave bands on the second and third harmonic, respectively.
ERIC Educational Resources Information Center
Cheng, Ivy K. Y.; Chan, Karen M. K.; Wong, C. S.; Cheung, Raymond T. F.
2015-01-01
Background: There is growing evidence of potential benefits of repetitive transcranial magnetic stimulation (rTMS) in the rehabilitation of dysphagia. However, the site and frequency of stimulation for optimal effects are not clear. Aims: The aim of this pilot study is to investigate the short-term effects of high-frequency 5 Hz rTMS applied to…
Chen, Mei-Yen; Wang, Edward K; Jeng, Yi-Jong
2006-03-08
Amount of sleep is an important indicator of health and well-being in children and adolescents. Adequate sleep (AS: adequate sleep is defined as 6-8 hours per night regularly) is a critical factor in adolescent health and health-related behaviors. The present study was based on a health promotion project previously conducted on adolescents in Tao-Yuan County, Taiwan. The aim was to examine the relationship between AS during schooldays and excessive body weight, frequency of visiting doctors and health-related behaviors among Taiwanese adolescents. A cross-sectional study design, categorical and multivariate data analyses were used. The hypotheses investigated were: high frequency of AS is positively associated with lack of obesity and less frequent visits to doctors; and high frequency AS is positively associated with health-related behavior. A total of 656 boys (53.2%) and girls (46.8%), ranging in age from 13-18 years were studied between January and June 2004. Three hundred and fifty seven subjects (54%) reported that they slept less than the suggested 6-8 hours on schooldays. A significant negative association was found between low sleep and of the following health-related behaviors: (1) life appreciation; (2) taking responsibility for health; (3) adopting healthy diet; (4) effective stress management; (5) regular exercise; and (6) total AHP score. High frequency AS was associated with low frequencies of obesity after potential confounding factors were controlled. Junior high school adolescents reported significantly higher frequencies of AS than high school participants. Gender, family structure, home location and frequency of television watching or computer use were not significantly associated with AS. These findings support the proposition that AS is associated with good health status and high-frequency adoption of health-related behavior. Furthermore, these findings suggest that inadequate sleep may be a screening indicator for an unhealthy lifestyle and poor health status. The results might be useful for future research into the development of intervention strategies to assist adolescents who are not receiving enough hours of sleep.
Predictors of seizure occurrence in children undergoing pre-surgical monitoring.
Harini, Chellamani; Singh, Kanwaljit; Takeoka, Masanori; Parulkar, Isha; Bergin, Ann Marie; Loddenkemper, Tobias; Kothare, Sanjeev V
2013-10-01
Long-Term-Monitoring (LTM) is a valuable tool for seizure localization/lateralization among children with refractory-epilepsy undergoing pre-surgical-monitoring. The aim of this study was to examine the factors predicting occurrence of single/multiple seizures in children undergoing pre-surgical monitoring in the LTM unit. Chart review was done on 95 consecutive admissions on 92 children (40 females) admitted to the LTM-unit for pre-surgical workup. Relationship between occurrence of multiple (≥ 3) seizures and factors such as home seizure-frequency, demographics, MRI-lesions/seizure-type and localization/AED usage/neurological-exam/epilepsy-duration was evaluated by logistic-regression and survival-analysis. Home seizure-frequency was further categorized into low (up-to 1/month), medium (up-to 1/week) and high (>1/week) and relationship of these categories to the occurrence of multiple seizures was evaluated. Mean length of stay was 5.24 days in all 3 groups. Home seizure frequency was the only factor predicting the occurrence of single/multiple seizures in children undergoing presurgical workup. Other factors (age/sex/MRI-lesions/seizure-type and localization/AED-usage/neurological-exam/epilepsy-duration) did not affect occurrence of single/multiple seizures or time-to-occurrence of first/second seizure. Analysis of the home-seizure frequency categories revealed that 98% admissions in high-frequency, 94% in the medium, and 77% in low-frequency group had at-least 1 seizure recorded during the monitoring. Odds of first-seizure increased in high vs. low-frequency group (p=0.01). Eighty-nine percent admissions in high-frequency, 78% in medium frequency, versus 50% in low-frequency group had ≥ 3 seizures. The odds of having ≥ 3 seizures increased in high-frequency (p=0.0005) and in medium-frequency (p=0.007), compared to low-frequency group. Mean time-to-first-seizure was 2.7 days in low-frequency, 2.1 days in medium, and 2 days in high-frequency group. Time-to-first-seizure in high and medium-frequency was less than in low-frequency group (p<0.0014 and p=0.038). Majority of the admissions (92%) admitted to the LTM-unit for pre-surgical workup had at-least one seizure during a mean length of stay of 5.24 days. Home seizure-frequency was the only predictor influencing occurrence of single/multiple seizures in the LTM unit. Patients with low seizure-frequency are at risk for completing the monitoring with less than the optimum number (<3) of seizures captured. Copyright © 2013 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Gao, Xuetong; Liu, Zhian; Zhao, Judong
2018-01-01
Compared to other treatment of industrial circulating cooling water in the field of industrial water treatment, high-voltage electrostatic field and variable frequency pulsed electromagnetic field co-sterilization technology, an advanced technology, is widely used because of its special characteristics--low energy consumption, nonpoisonous and environmentally friendly. In order to get a better cooling water sterilization effect under the premise of not polluting the environment, some experiments about sterilization of heterotrophic bacteria in industrial circulating cooling water by cooperative treatment of high voltage electrostatic field and variable frequency pulsed electromagnetic field were carried out. The comparison experiment on the sterilization effect of high-voltage electrostatic field and variable frequency pulsed electromagnetic field co-sterilization on heterotrophic bacteria in industrial circulating cooling water was carried out by change electric field strength and pulse frequency. The results show that the bactericidal rate is selective to the frequency and output voltage, and the heterotrophic bacterium can only kill under the condition of sweep frequency range and output voltage. When the voltage of the high voltage power supply is 4000V, the pulse frequency is 1000Hz and the water temperature is 30°C, the sterilization rate is 48.7%, the sterilization rate is over 90%. Results of this study have important guiding significance for future application of magnetic field sterilization.
CASTELLANOS-RYAN, NATALIE; PINGAULT, JEAN-BAPTISTE; PARENT, SOPHIE; VITARO, FRANK; TREMBLAY, RICHARD E.; SÉGUIN, JEAN R.
2017-01-01
The main objective of this prospective longitudinal study was to investigate bidirectional associations between adolescent cannabis use (CU) and neurocognitive performance in a community sample of 294 young men from ages 13 to 20 years. The results showed that in early adolescence, and prior to initiation to CU, poor short-term and working memory, but high verbal IQ, were associated with earlier age of onset of CU. In turn, age of CU onset and CU frequency across adolescence were associated with (a) specific neurocognitive decline in verbal IQ and executive function tasks tapping trial and error learning and reward processing by early adulthood and (b) lower rates of high-school graduation. The association between CU onset and change in neurocognitive function, however, was found to be accounted for by CU frequency. Whereas the link between CU frequency across adolescence and change in verbal IQ was explained (mediated) by high school graduation, the link between CU frequency and tasks tapping trial and error learning were independent from high school graduation, concurrent cannabis and other substance use, adolescent alcohol use, and externalizing behaviors. Findings support prevention efforts aimed at delaying onset and reducing frequency of CU. PMID:28031069
NASA Astrophysics Data System (ADS)
Chiu, Alan W. L.; Jahromi, Shokrollah S.; Khosravani, Houman; Carlen, Peter L.; Bardakjian, Berj L.
2006-03-01
The existence of hippocampal high-frequency electrical activities (greater than 100 Hz) during the progression of seizure episodes in both human and animal experimental models of epilepsy has been well documented (Bragin A, Engel J, Wilson C L, Fried I and Buzsáki G 1999 Hippocampus 9 137-42 Khosravani H, Pinnegar C R, Mitchell J R, Bardakjian B L, Federico P and Carlen P L 2005 Epilepsia 46 1-10). However, this information has not been studied between successive seizure episodes or utilized in the application of seizure classification. In this study, we examine the dynamical changes of an in vitro low Mg2+ rat hippocampal slice model of epilepsy at different frequency bands using wavelet transforms and artificial neural networks. By dividing the time-frequency spectrum of each seizure-like event (SLE) into frequency bins, we can analyze their burst-to-burst variations within individual SLEs as well as between successive SLE episodes. Wavelet energy and wavelet entropy are estimated for intracellular and extracellular electrical recordings using sufficiently high sampling rates (10 kHz). We demonstrate that the activities of high-frequency oscillations in the 100-400 Hz range increase as the slice approaches SLE onsets and in later episodes of SLEs. Utilizing the time-dependent relationship between different frequency bands, we can achieve frequency-dependent state classification. We demonstrate that activities in the frequency range 100-400 Hz are critical for the accurate classification of the different states of electrographic seizure-like episodes (containing interictal, preictal and ictal states) in brain slices undergoing recurrent spontaneous SLEs. While preictal activities can be classified with an average accuracy of 77.4 ± 6.7% utilizing the frequency spectrum in the range 0-400 Hz, we can also achieve a similar level of accuracy by using a nonlinear relationship between 100-400 Hz and <4 Hz frequency bands only.
Harbour porpoises react to low levels of high frequency vessel noise
Dyndo, Monika; Wiśniewska, Danuta Maria; Rojano-Doñate, Laia; Madsen, Peter Teglberg
2015-01-01
Cetaceans rely critically on sound for navigation, foraging and communication and are therefore potentially affected by increasing noise levels from human activities at sea. Shipping is the main contributor of anthropogenic noise underwater, but studies of shipping noise effects have primarily considered baleen whales due to their good hearing at low frequencies, where ships produce most noise power. Conversely, the possible effects of vessel noise on small toothed whales have been largely ignored due to their poor low-frequency hearing. Prompted by recent findings of energy at medium- to high-frequencies in vessel noise, we conducted an exposure study where the behaviour of four porpoises (Phocoena phocoena) in a net-pen was logged while they were exposed to 133 vessel passages. Using a multivariate generalised linear mixed-effects model, we show that low levels of high frequency components in vessel noise elicit strong, stereotyped behavioural responses in porpoises. Such low levels will routinely be experienced by porpoises in the wild at ranges of more than 1000 meters from vessels, suggesting that vessel noise is a, so far, largely overlooked, but substantial source of disturbance in shallow water areas with high densities of both porpoises and vessels. PMID:26095689
NASA Astrophysics Data System (ADS)
der, Z. A.; Blandford, R. R.
1981-03-01
A survey of the literature on short period seismic studies showed that seismic waves of high frequency in the 3-10 Hz range can be observed regularly at both regional and teleseismic distances. These observations show that the low Q values proposed for the long period seismic waves cannot be valid in the short period band. The data indicate that, in the mantle, Q increases with frequency and may be as much as five times higher at 5-10 Hz than in the long period band. Even with the most conservative assumptions, the level of high frequency amplitudes in the teleseismic P waves exceeds that predicted with a constant t*p = 1 sec by a factor of at least 100,000 at and beyond 5 Hz. The apparent Q beta of the lithosphere, which may be largely due to scattering by the small scale inhomogeneities in the crust, also shows an increase with frequency by as much as a factor of four within the 1-10 Hz band. This parameter controls the attenuation and the detectability of seismic waves at regional distances such as Pn, Pg, Su and Lg.
Cortical theta wanes for language.
Hermes, Dora; Miller, Kai J; Vansteensel, Mariska J; Edwards, Erik; Ferrier, Cyrille H; Bleichner, Martin G; van Rijen, Peter C; Aarnoutse, Erik J; Ramsey, Nick F
2014-01-15
The role of low frequency oscillations in language areas is not yet understood. Using ECoG in six human subjects, we studied whether different language regions show prominent power changes in a specific rhythm, in similar manner as the alpha rhythm shows the most prominent power changes in visual areas. Broca's area and temporal language areas were localized in individual subjects using fMRI. In these areas, the theta rhythm showed the most pronounced power changes and theta power decreased significantly during verb generation. To better understand the role of this language-related theta decrease, we then studied the interaction between low frequencies and local neuronal activity reflected in high frequencies. Amplitude-amplitude correlations showed that theta power correlated negatively with high frequency activity, specifically across verb generation trials. Phase-amplitude coupling showed that during control trials, high frequency power was coupled to theta phase, but this coupling decreased significantly during verb generation trials. These results suggest a dynamic interaction between the neuronal mechanisms underlying the theta rhythm and local neuronal activity in language areas. As visual areas show a pronounced alpha rhythm that may reflect pulsed inhibition, language regions show a pronounced theta rhythm with highly similar features. © 2013.
Momota, Yukihiro; Takano, Hideyuki; Kani, Koichi; Matsumoto, Fumihiro; Motegi, Katsumi; Aota, Keiko; Yamamura, Yoshiko; Omori, Mayuko; Tomioka, Shigemasa; Azuma, Masayuki
2013-03-01
Burning mouth syndrome (BMS) is characterized by the following subjective complaints without distinct organic changes: burning sensation in mouth or chronic pain of tongue. BMS is also known as glossodynia; both terms are used equivalently in Japan. Although the real cause of BMS is still unknown, it has been pointed out that BMS is related to some autonomic abnormality, and that stellate ganglion near-infrared irradiation (SGR) corrects the autonomic abnormality. Frequency analysis of heart rate variability (HRV) is expected to be useful for assessing autonomic abnormality. This study investigated whether frequency analysis of HRV could reveal autonomic abnormality associated with BMS, and whether autonomic changes were corrected after SGR. Eight subjects received SGR; the response to SGR was assessed by frequency analysis of HRV. No significant difference of autonomic activity concerning low-frequency (LF) norm, high-frequency (HF) norm, and low-frequency/high-frequency (LF/HF) was found between SGR effective and ineffective groups. Therefore, we proposed new parameters: differential normalized low frequency (D LF norm), differential normalized high frequency (D HF norm), and differential low-frequency/high-frequency (D LF/HF), which were defined as differentials between original parameters just before and after SGR. These parameters as indexes of responsiveness of autonomic nervous system (ANS) revealed autonomic changes in BMS, and BMS seems to be related to autonomic instability rather than autonomic imbalance. Frequency analysis of HRV revealed the autonomic instability associated with BMS and enabled tracing of autonomic changes corrected with SGR. It is suggested that frequency analysis of HRV is very useful in follow up of BMS and for determination of the therapeutic efficacy of SGR. Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Criss, Amy H.; Malmberg, Kenneth J.
2008-01-01
One of the most studied and least well understood phenomena in episodic memory is the word frequency effect (WFE). The WFE is expressed as a mirror pattern where uncommon low frequency words (LF) are better recognized than common high frequency words (HF) by way of a higher HR and lower FAR. One explanation for the HR difference is the early-phase…
NASA Astrophysics Data System (ADS)
Liu, You; Yuan, Zhi-Guo; Fan, Li-Yun; Tian, Bin-Qi
2010-12-01
The electronic in-line pump (EIP) is a complex system consisting of mechanical, hydraulic, and electromagnetic parts. Experimental study showed that the fuel pressure of the plunger and the fuel drainage of the pressure system after fuel injection could result in fuel pressure fluctuation in the low pressure system. Such fluctuation exhibited pulsating cycle fluctuation as the amplitude rose with the increase of the injection pulse width. The time domain analysis found that the pressure time history curve and injection cylinders corresponded with a one-to-one relationship. By frequency domain analysis, the result was that with the increase of the working cylinder number, the high frequency amplitude gradually increased and the basic frequency amplitude gradually decreased. The conclusion was that through wavelet transformation, the low pressure signal simultaneously moved towards low frequency as the high frequency of the wavelet transformation signal with the working cylinder number increased. Lastly, by using the numerical model, the study investigated the simulation research concerning the relationship of the fluctuation dynamic characteristic in the low pressure system and the fuel injection characteristic of the high pressure system, completing the conclusions obtained by the experimental study.
Stress Patterns in High-Frequency Russian Nouns and Verbs.
ERIC Educational Resources Information Center
Cubberley, Paul
1987-01-01
Analyses for stress patterns of the first 1,000 nouns and 500 verbs from a high-frequency Russian vocabulary list. The most irregular patterns are seen in the most frequently occurring items and, therefore, should be learned early in the study of Russian. (Author/LMO)
Marinesco bodies and substantia nigra neuron density in Parkinson's disease.
Abbott, R D; Nelson, J S; Ross, G W; Uyehara-Lock, J H; Tanner, C M; Masaki, K H; Launer, L J; White, L R; Petrovitch, H
2017-12-01
Marinesco bodies (MB) are intranuclear inclusions in pigmented neurons of the substantia nigra (SN). While rare in children, frequency increases with normal ageing and is high in Alzheimer's disease, dementia with Lewy bodies and other neurodegenerative disorders. Coinciding with the age-related rise in MB frequency is initiation of cell death among SN neurons. Whether MB have a role in this process is unknown. Our aim is to examine the association of MB with SN neuron density in Parkinson's disease (PD) in the Honolulu-Asia Aging Study. Data on MB and neuron density were measured in SN transverse sections in 131 autopsied men aged 73-99 years at the time of death from 1992 to 2007. Marinesco body frequency was low in the presence vs. absence of PD (2.3% vs. 6.6%, P < 0.001). After PD onset, MB frequency declined as duration of PD increased (P = 0.006). Similar patterns were observed for SN neuron density. When MB frequency was low, neuron density was noticeably reduced in the SN ventrolateral quadrant, the region most vulnerable to PD neurodegeneration. Low MB frequency was unique to PD as its high frequency in non-PD cases was unrelated to parkinsonian signs and incidental Lewy bodies. Frequency was high in the presence of Alzheimer's disease and apolipoprotein ε4 alleles. While findings confirm that MB frequency is low in PD, declines in MB frequency continue with PD duration. The extent to which MB have a distinct relationship with PD warrants clarification. Further studies of MB could be important in understanding PD processes. © 2017 British Neuropathological Society.
Campos, Filippe V; Neves, Laura M; Da Silva, Vinicius Z; Cipriano, Graziella F; Chiappa, Gaspar R; Cahalin, Lawrence; Arena, Ross; Cipriano, Gerson
2016-05-01
To determine the immediate effects of transcutaneous electrical nerve stimulation (TENS) on heart rate, systolic blood pressure (SBP), and diastolic blood pressure (DBP) in apparently healthy adults (age ≥18y). The Cochrane Library (online version 2014), PubMed (1962-2014), EMBASE (1980-2014), and LILACS (1980-2014) electronic databases were searched. Randomized controlled trials were included when TENS was administered noninvasively with surface electrodes during rest, and the effect of TENS was compared with that of control or placebo TENS. A sensitive search strategy for identifying randomized controlled trials was used by 2 independent reviewers. The initial search led to the identification of 432 studies, of which 5 articles met the eligibility criteria. Two independent reviewers extracted data from the selected studies. Quality was evaluated using the PEDro scale. Mean differences or standardized mean differences in outcomes were calculated. Five eligible articles involved a total of 142 apparently healthy individuals. Four studies used high-frequency TENS and 3 used low-frequency TENS and evaluated the effect on SBP. Three studies using high-frequency TENS and 2 using low-frequency TENS evaluated the effect on DBP. Three studies using high-frequency TENS and 1 study using low-frequency TENS evaluated the effect on heart rate. A statistically significant reduction in SBP (-3.00mmHg; 95% confidence interval [CI], -5.02 to -0.98; P=.004) was found using low-frequency TENS. A statistically significant reduction in DBP (-1.04mmHg; 95% CI, -2.77 to -0.03; I(2)=61%; P=.04) and in heart rate (-2.55beats/min; 95% CI, -4.31 to -0.78; I(2)=86%; P=.005]) was found using both frequencies. The median value on the PEDro scale was 7 (range, 4-8). TENS seems to promote a discrete reduction in SBP, DBP, and heart rate in apparently healthy individuals. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
High-frequency tone burst-evoked ABR latency-intensity functions.
Fausti, S A; Olson, D J; Frey, R H; Henry, J A; Schaffer, H I
1993-01-01
High-frequency tone burst stimuli (8, 10, 12, and 14 kHz) have been developed and demonstrated to provide reliable and valid auditory brainstem responses (ABRs) in normal-hearing subjects. In this study, latency-intensity functions (LIFs) were determined using these stimuli in 14 normal-hearing individuals. Significant shifts in response latency occurred as a function of stimulus intensity for all tone burst frequencies. For each 10 dB shift in intensity, latency shifts for waves I and V were statistically significant except for one isolated instance. LIF slopes were comparable between frequencies, ranging from 0.020 to 0.030 msec/dB. These normal LIFs for high-frequency tone burst-evoked ABRs suggest the degree of response latency change that might be expected from, for example, progressive hearing loss due to ototoxic insult, although these phenomena may not be directly related.
Study of noise reduction characteristics of double-wall panels
NASA Technical Reports Server (NTRS)
Navaneethan, R.; Quayle, B.; Stevenson, S.; Graham, M.
1983-01-01
The noise reduction characteristics of general aviation type, flat, double-wall structures were investigated. The experimental study was carried out on 20-by-20 inch panels with an exposed area of 18 by 18 inches. A frequency range from 20 to 5000 Hz was covered. The experimental results, in general, follow the expected trends. At low frequencies the double-wall structures are no better than the single-wall structures. However, for depths normally used in the general aviation industry, the double-wall panels are very attractive. The graphite-spoxy skin panels have higher noise reduction at very low frequencies ( 100 Hz) than the Kevlar skin panels. But the aluminum panels have higher noise reduction in the high frequency region, due to their greater mass. Use of fiberglass insulation is not effective in the low frequency region, and at times it is even negative. But the insulation is effective in the high-frequency region. The theoretical model for predicting the transmission loss of these multilayered panels is also discussed.
Study of noise reduction characteristics of double-wall panels
NASA Astrophysics Data System (ADS)
Navaneethan, R.; Quayle, B.; Stevenson, S.; Graham, M.
1983-05-01
The noise reduction characteristics of general aviation type, flat, double-wall structures were investigated. The experimental study was carried out on 20-by-20 inch panels with an exposed area of 18 by 18 inches. A frequency range from 20 to 5000 Hz was covered. The experimental results, in general, follow the expected trends. At low frequencies the double-wall structures are no better than the single-wall structures. However, for depths normally used in the general aviation industry, the double-wall panels are very attractive. The graphite-spoxy skin panels have higher noise reduction at very low frequencies ( 100 Hz) than the Kevlar skin panels. But the aluminum panels have higher noise reduction in the high frequency region, due to their greater mass. Use of fiberglass insulation is not effective in the low frequency region, and at times it is even negative. But the insulation is effective in the high-frequency region. The theoretical model for predicting the transmission loss of these multilayered panels is also discussed.
Winsler, Kurt; Holcomb, Phillip J; Midgley, Katherine J; Grainger, Jonathan
2017-01-01
Previous studies have shown that different spatial frequency information processing streams interact during the recognition of visual stimuli. However, it is a matter of debate as to the contributions of high and low spatial frequency (HSF and LSF) information for visual word recognition. This study examined the role of different spatial frequencies in visual word recognition using event-related potential (ERP) masked priming. EEG was recorded from 32 scalp sites in 30 English-speaking adults in a go/no-go semantic categorization task. Stimuli were white characters on a neutral gray background. Targets were uppercase five letter words preceded by a forward-mask (#######) and a 50 ms lowercase prime. Primes were either the same word (repeated) or a different word (un-repeated) than the subsequent target and either contained only high, only low, or full spatial frequency information. Additionally within each condition, half of the prime-target pairs were high lexical frequency, and half were low. In the full spatial frequency condition, typical ERP masked priming effects were found with an attenuated N250 (sub-lexical) and N400 (lexical-semantic) for repeated compared to un-repeated primes. For HSF primes there was a weaker N250 effect which interacted with lexical frequency, a significant reversal of the effect around 300 ms, and an N400-like effect for only high lexical frequency word pairs. LSF primes did not produce any of the classic ERP repetition priming effects, however they did elicit a distinct early effect around 200 ms in the opposite direction of typical repetition effects. HSF information accounted for many of the masked repetition priming ERP effects and therefore suggests that HSFs are more crucial for word recognition. However, LSFs did produce their own pattern of priming effects indicating that larger scale information may still play a role in word recognition.
Dingemans, Jozef; Eyns, Hanneke; Willekens, Julie; Monsieurs, Pieter; Van Houdt, Rob; Cornelis, Pierre; Malfroot, Anne; Crabbé, Aurélie
2018-06-01
High levels of shear stress can prevent and disrupt Pseudomonas aeruginosa biofilm formation in vitro. Intrapulmonary percussive ventilation (IPV) could be used to introduce shear stress into the lungs of cystic fibrosis (CF) patients to disrupt biofilms in vivo. We performed a first-of-its-kind pilot clinical study to evaluate short-term IPV therapy at medium (200 bursts per minute, bpm) and high frequency (400 bpm) as compared to autogenic drainage (AD) on lung function and the behavior of P. aeruginosa in the CF lung in four patients who are chronically colonized by P. aeruginosa. A significant difference between the three treatment groups was observed for both the forced expiratory volume in 1 s (FEV1) and the forced vital capacity (FVC) (p < 0.05). More specifically, IPV at high frequency significantly increased FEV1 and FVC compared to AD (p < 0.05) and IPV at medium frequency (p < 0.001). IPV at high frequency enhanced the expression levels of P. aeruginosa planktonic marker genes, which was less pronounced with IPV at medium frequency or AD. In conclusion, IPV at high frequency could potentially alter the behavior of P. aeruginosa in the CF lung and improve lung function. The trail was retrospectively registered at the ISRCTN registry on 6 June 2013, under trial registration number ISRCTN75391385.
NASA Astrophysics Data System (ADS)
Hensley, R. T.; Cohen, M. J.; Spangler, M.; Gooseff, M. N.
2017-12-01
The lower Santa Fe River is a large, karst river of north Florida, fed by numerous artesian springs and also containing multiple sink-rise systems. We performed repeated longitudinal profiles collecting very high frequency measurements of multiple stream parameters including temperature, dissolved oxygen, carbon dioxide, pH, dissolved organic matter, nitrate, ammonium, phosphate and turbidity. This high frequency dataset provided a spatially explicit understanding of solute sources and coupled biogeochemical processing rates along the 25 km study reach. We noted marked changes in river profiles as the river transitioned from low to high flow during the onset of the wet season. The role of lateral inflow from springs as the primary solute source was greatly reduced under high flow conditions. Effects of sink-rise systems, which under low flow conditions allow the majority of flow to bypass several kilometer long sections of the main channel, virtually disappeared under high flow conditions. Impeded light transmittance at high flow reduced primary production and by extension assimilatory nutrient uptake. This study demonstrates how high frequency longitudinal profiling can be used to observe how hydrologic conditions can alter groundwater-surface water interactions and modulate the sourcing, transport and biogeochemical processing of stream solutes.
The Influence of Item Properties on Association-Memory
ERIC Educational Resources Information Center
Madan, Christopher R.; Glaholt, Mackenzie G.; Caplan, Jeremy B.
2010-01-01
Word properties like imageability and word frequency improve cued recall of verbal paired-associates. We asked whether these enhancements follow simply from prior effects on item-memory, or also strengthen associations between items. Participants studied word pairs varying in imageability or frequency: pairs were "pure" (high-high, low-low) or…
Practical techniques for enhancing the high-frequency MASW method
USDA-ARS?s Scientific Manuscript database
For soil exploration in the vadose zone, a high-frequency multi-channel analysis of surface waves (HF-MASW) method has been developed. In the study, several practical techniques were applied to enhance the overtone image of the HF-MASW method. They included (1) the self-adaptive MASW method using a ...
Multi-frequency localization of aberrant brain activity in autism spectrum disorder.
Xiang, Jing; Korostenskaja, Milena; Molloy, Cynthia; deGrauw, Xinyao; Leiken, Kimberly; Gilman, Carley; Meinzen-Derr, Jareen; Fujiwara, Hisako; Rose, Douglas F; Mitchell, Terry; Murray, Donna S
2016-01-01
The abnormality of intrinsic brain activity in autism spectrum disorders (ASDs) is still inconclusive. Contradictory results have been found pointing towards hyper-activity or hypo-activity in various brain regions. The present research aims to investigate the spatial and spectral signatures of aberrant brain activity in an unprecedented frequency range of 1-2884 Hz at source levels in ASD using newly developed methods. Seven ASD subjects and age- and gender-matched controls were studied using a high-sampling rate magnetoencephalography (MEG) system. Brain activity in delta (1-4 Hz), theta (4-8 Hz), alpha (8-12 Hz), beta (12-30 Hz), low gamma (30-55 Hz), high gamma (65-90 Hz), ripples (90-200 Hz), high-frequency oscillations (HFOs, 200-1000 Hz), and very high-frequency oscillations (VHFOs, 1000-2884 Hz) was volumetrically localized and measured using wavelet and beamforming. In comparison to controls, ASD subjects had significantly higher odds of alpha activity (8-12 Hz) in the sensorimotor cortex (mu rhythm), and generally high-frequency activity (90-2884 Hz) in the frontal cortex. The source power of HFOs (200-1000 Hz) in the frontal cortex in ASD was significantly elevated as compared with controls. The results suggest that ASD has significantly altered intrinsic brain activity in both low- and high-frequency ranges. Increased intrinsic high-frequency activity in the frontal cortex may play a key role in ASD. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
High-frequency self-aligned graphene transistors with transferred gate stacks
Cheng, Rui; Bai, Jingwei; Liao, Lei; Zhou, Hailong; Chen, Yu; Liu, Lixin; Lin, Yung-Chen; Jiang, Shan; Huang, Yu; Duan, Xiangfeng
2012-01-01
Graphene has attracted enormous attention for radio-frequency transistor applications because of its exceptional high carrier mobility, high carrier saturation velocity, and large critical current density. Herein we report a new approach for the scalable fabrication of high-performance graphene transistors with transferred gate stacks. Specifically, arrays of gate stacks are first patterned on a sacrificial substrate, and then transferred onto arbitrary substrates with graphene on top. A self-aligned process, enabled by the unique structure of the transferred gate stacks, is then used to position precisely the source and drain electrodes with minimized access resistance or parasitic capacitance. This process has therefore enabled scalable fabrication of self-aligned graphene transistors with unprecedented performance including a record-high cutoff frequency up to 427 GHz. Our study defines a unique pathway to large-scale fabrication of high-performance graphene transistors, and holds significant potential for future application of graphene-based devices in ultra–high-frequency circuits. PMID:22753503
A role for high frequency hydrochemical sampling in long term ecosystem studies
NASA Astrophysics Data System (ADS)
Sebestyen, S. D.; Shanley, J. B.; Boyer, E. W.; Kendall, C.
2007-12-01
Monitoring of surface waters for major chemical constituents is needed to assess long-term trends and responses to ecological disturbance. However, the typical fixed-interval (weekly, monthly, or quarterly) sampling schemes of most long-term ecosystem studies may not capture the full range of stream chemical variation and do not always provide enough information to discern the landscape processes that control surface water chemistry and solute loadings. To expand upon traditional hydrochemical monitoring, we collected high frequency event-based surface water samples at an upland, forested basin of the Sleepers River Research Watershed (Vermont, USA), one of five intensively studied sites in the Water, Energy, and Biogeochemical Budgets (WEBB) program of the US Geological Survey. We present several examples that highlight the importance of linking long-term weekly data with intensive, high frequency sampling. We used end-member mixing analysis and isotopic approaches to trace sources of stream nutrients (e.g. nitrate, dissolved organic carbon) and quantified how atmospheric pollutants (e.g. nitrogen, sulfate, and mercury) affect stream chemistry. High frequency sampling generates large numbers of samples and is both labor and resource intensive but yields insights into ecosystem functions that are not readily discerned from less-frequent sampling. As the ecological community contemplates the scope and foci of environmental observatories as benchmarks for deciphering the effects of natural and anthropogenic change, incorporating high frequency hydrochemical sampling will further our understanding of ecosystem functions across a range of ecosystem types and disturbance effects.
High temperature dielectric studies of indium-substituted NiCuZn nanoferrites
NASA Astrophysics Data System (ADS)
Hashim, Mohd.; Raghasudha, M.; Shah, Jyoti; Shirsath, Sagar E.; Ravinder, D.; Kumar, Shalendra; Meena, Sher Singh; Bhatt, Pramod; Alimuddin; Kumar, Ravi; Kotnala, R. K.
2018-01-01
In this study, indium (In3+)-substituted NiCuZn nanostructured ceramic ferrites with a chemical composition of Ni0.5Cu0.25Zn0.25Fe2-xInxO4 (0.0 ≤ x ≤ 0.5) were prepared by chemical synthesis involving sol-gel chemistry. Single phased cubic spinel structure materials were prepared successfully according to X-ray diffraction and transmission electron microscopy analyses. The dielectric properties of the prepared ferrites were measured using an LCR HiTester at temperatures ranging from room temperature to 300 °C at different frequencies from 102 Hz to 5 × 106 Hz. The variations in the dielectric parameters ε‧ and (tanδ) with temperature demonstrated the frequency- and temperature-dependent characteristics due to electron hopping between the ions. The materials had low dielectric loss values in the high frequency range at all temperatures, which makes them suitable for high frequency microwave applications. A qualitative explanation is provided for the dependences of the dielectric constant and dielectric loss tangent on the frequency, temperature, and composition. Mӧssbauer spectroscopy was employed at room temperature to characterize the magnetic behavior.
2012-01-01
Background The frequency of E-cadherin germline mutations in countries with different incidence rates for gastric carcinoma has not been well established. The goal of this study was to assess the worldwide frequency of CDH1 germline mutations in gastric cancers coming from low- and high-risk areas. Methods English articles using MEDLINE access (from 1998 to 2011). Search terms included CDH1, E-cadherin, germline mutation, gastric cancer, hereditary, familial and diffuse histotype. The study included all E-cadherin germline mutations identified in gastric cancer patients; somatic mutations and germline mutations reported in other tumors were excluded. The method of this study was scheduled in accordance with the "PRISMA statement for reporting systematic reviews and meta-analyses". Countries were classified as low- or middle/high risk-areas for gastric carcinoma incidence. Statistical analysis was performed to correlate the CDH1 mutation frequency with gastric cancer incidence areas. Results A total of 122 E-cadherin germline mutations have been identified; the majority (87.5%) occurred in gastric cancers coming from low-risk areas. In high-risk areas, we identified 16 mutations in which missense mutations were predominant. (68.8%). We verified a significant association between the mutation frequency and the gastric cancer risk area (p < 0.001: overall identified mutations in low- vs. middle/high-risk areas). Conclusions E-cadherin genetic screenings performed in low-risk areas for gastric cancer identified a higher frequency of CDH1 germline mutations. This data could open new approaches in the gastric cancer prevention test; before proposing a proband candidate for the CDH1 genetic screening, geographic variability, alongside the family history should be considered. PMID:22225527
Nonlinear heating of ions by electron cyclotron frequency waves
NASA Astrophysics Data System (ADS)
Zestanakis, P. A.; Hizanidis, K.; Ram, A. K.; Kominis, Y.
2010-11-01
We study the nonlinear interaction of ions with electron cyclotron (EC) wave packets in a magnetized plasma. Previous studies have shown that such interactions with high frequency electrostatic lower hybrid waves can lead to coherent energization of ions. It requires the frequency bandwidth of the wave packet to be broader than the ion cyclotron frequency [1,2]. For the electromagnetic high frequency EC waves we have developed a more general theory, based on the Lie transform canonical perturbation method [3,4]. We apply the theory to the case of two overlapping EC beams. The wave frequency of each beam is assumed to be frequency modulated with a modulation bandwidth comparable to the ion cyclotron frequency. We present results for both X-mode and O-mode and illustrate the conditions for ion energization. [4pt] [1] D. Benisti, A. K. Ram, and A. Bers, Phys. Plasmas 5, 3224 (1998). [0pt] [2] A. K. Ram, A. Bers, and D. Benisti , J. Geophys. Res. 103, 9431 (1998). [0pt] [3] J.R. Cary and A.N. Kaufman, Phys. Fluids 24, 1238 (1981). [0pt] [4] R.L. Dewar, J. Phys A-Math. Gen 9, 2043 (1976).
Variation of Static-PPP Positioning Accuracy Using GPS-Single Frequency Observations (Aswan, Egypt)
NASA Astrophysics Data System (ADS)
Farah, Ashraf
2017-06-01
Precise Point Positioning (PPP) is a technique used for position computation with a high accuracy using only one GNSS receiver. It depends on highly accurate satellite position and clock data rather than broadcast ephemeries. PPP precision varies based on positioning technique (static or kinematic), observations type (single or dual frequency) and the duration of collected observations. PPP-(dual frequency receivers) offers comparable accuracy to differential GPS. PPP-single frequency receivers has many applications such as infrastructure, hydrography and precision agriculture. PPP using low cost GPS single-frequency receivers is an area of great interest for millions of users in developing countries such as Egypt. This research presents a study for the variability of single frequency static GPS-PPP precision based on different observation durations.
Mechanical and electrical tuning in a tonotopically organized insect ear
NASA Astrophysics Data System (ADS)
Hummel, Jennifer; Schöneich, Stefan; Hedwig, Berthold; Kössl, Manfred; Nowotny, Manuela
2015-12-01
The high-frequency hearing organ of bushcrickets - the crista acustica (CA) - is tonotopically organized. Details about the mechano-electrical transduction mechanisms within the sensory-cell complex, however, remain unknown. In the recent study, we investigated and compared the anatomical, mechanical and electrophysiological properties of the CA and reveal a strong correlation of the mechanical and neuronal frequency tuning, which is supported by an anatomical gradient along the CA. Only in the distal high-frequency region of the CA a discrepancy between a strong mechanical response to low frequencies <30 kHz and a neuronal response that was restricted to frequencies >30 kHz was found. Therefore, we suggest that there might be additional intrinsic tuning mechanisms in the sensory cells of the distal region to distinguish the frequency content of sound.
NASA Astrophysics Data System (ADS)
Xiao, Zhili; Tan, Chao; Dong, Feng
2017-08-01
Magnetic induction tomography (MIT) is a promising technique for continuous monitoring of intracranial hemorrhage due to its contactless nature, low cost and capacity to penetrate the high-resistivity skull. The inter-tissue inductive coupling increases with frequency, which may lead to errors in multi-frequency imaging at high frequency. The effect of inter-tissue inductive coupling was investigated to improve the multi-frequency imaging of hemorrhage. An analytical model of inter-tissue inductive coupling based on the equivalent circuit was established. A set of new multi-frequency decomposition equations separating the phase shift of hemorrhage from other brain tissues was derived by employing the coupling information to improve the multi-frequency imaging of intracranial hemorrhage. The decomposition error and imaging error are both decreased after considering the inter-tissue inductive coupling information. The study reveals that the introduction of inter-tissue inductive coupling can reduce the errors of multi-frequency imaging, promoting the development of intracranial hemorrhage monitoring by multi-frequency MIT.
Spectrum study on unsteadiness of shock wave-vortex ring interaction
NASA Astrophysics Data System (ADS)
Dong, Xiangrui; Yan, Yonghua; Yang, Yong; Dong, Gang; Liu, Chaoqun
2018-05-01
Shock oscillation with low-frequency unsteadiness commonly occurs in supersonic flows and is a top priority for the control of flow separation caused by shock wave and boundary layer interaction. In this paper, the interaction of the shock caused by the compression ramp and the vortex rings generated by a micro-vortex generator (MVG) in a supersonic flow at Ma = 2.5 is simulated by the implicit large eddy simulation method. The analysis of observation and the frequency of both the vortex ring motion and the shock oscillation is carried out. The results show that the shock produced by a compression ramp flow at Ma = 2.5 has a dominant non-dimensional low frequency, which is around St = 0.002, while the vortex rings behind the MVG have a dominant high frequency which is around St = 0.038. The dominant low frequency of the shock, which is harmful, can be removed or weakened through the shock-vortex ring interaction by the vortex rings which generate high frequency fluctuations. In the shock and vortex ring interaction region, a dominant high frequency St = 0.037-0.038 has been detected rather than the low frequency St = 0.002, which indicates that the vortex ring is stiff enough to break or weaken the shock. This analysis could provide an effective tool to remove or weaken the low frequency pressure fluctuation below 500 Hz, which has a negative effect on the flight vehicle structures and the environmental protection, through the high frequency vortex generation.
Park, Gewnhi; Moon, Eunok; Kim, Do-Won; Lee, Seung-Hwan
2012-12-01
A previous study has shown that greater cardiac vagal tone, reflecting effective self-regulatory capacity, was correlated with superior visual discrimination of fearful faces at high spatial frequency Park et al. (Biological Psychology 90:171-178, 2012b). The present study investigated whether individual differences in cardiac vagal tone (indexed by heart rate variability) were associated with different event-related brain potentials (ERPs) in response to fearful and neutral faces. Thirty-six healthy participants discriminated the emotion of fearful and neutral faces at broad, high, and low spatial frequencies, while ERPs were recorded. Participants with low resting heart rate variability-characterized by poor functioning of regulatory systems-exhibited significantly greater N200 activity in response to fearful faces at low spatial frequency and greater LPP responses to neutral faces at high spatial frequency. Source analyses-estimated by standardized low-resolution brain electromagnetic tomography (sLORETA)-tended to show that participants with low resting heart rate variability exhibited increased source activity in visual areas, such as the cuneus and the middle occipital gyrus, as compared with participants with high resting heart rate variability. The hyperactive neural activity associated with low cardiac vagal tone may account for hypervigilant response patterns and emotional dysregulation, which heightens the risk of developing physical and emotional problems.
Gapeev, A B; Shved, D M; Mikhaĭlik, E N; Korystov, Iu N; Levitman, M Kh; Shaposhnikova, V V; Sadovnikov, V B; Alekhin, A I; Goncharov, N G; Chemeris, N K
2009-01-01
The influence of different exposure regimes of low-intensity extremely high-frequency electromagnetic radiation on the growth rate of solid Ehrlich carcinoma in mice has been studied. It was shown that, at an optimum repetition factor of exposure (20 min daily for five consecutive days after the tumor inoculation), there is a clearly pronounced frequency dependence of the antitumor effect. The analysis of experimental data indicates that the mechanisms of antitumor effects of the radiation may be related to the modification of the immune status of the organism. The results obtained show that extremely high-frequency electromagnetic radiation at a proper selection of exposure regimes can result in distinct and stable antitumor effects.
Al-Swiahb, Jamil Nasser; Hwang, Eul Seung; Kong, Ji Sun; Kim, Woo Jin; Yeo, Sang Won; Park, Shi Nae
2016-12-01
This study was performed to analyze clinical and audiologic characteristics of sensorineural tinnitus and to investigate the associating factors reflecting psychological aspects of stress and depression of the patients. This is a retrospective analytical study conducted in a tinnitus clinic of a tertiary referral center of a university hospital. The medical records of 216 patients suffering from sensorineural tinnitus were thoroughly evaluated to determine correlations between clinical and audiological characteristics, including age, sex, predisposing or etiologic factors, hearing levels up to extended high frequencies, and tinnitus severity. Psychological aspects of stress and depression were also evaluated and analyzed to seek the associations with tinnitus severity. All data were stored in our database bank and were statistically analyzed. Our study subjects showed a slight male predominance. The highest percentage of tinnitus was found in patients of 60-80 years old. Only 32.5 % of tinnitus patients were subjectively aware of their hearing loss, whereas 73 % of subjects had hearing deficits in some frequencies in their audiogram. Hearing impairments were of the low-frequency sensorineural type in 18.2 % of patients and were limited to the high frequencies in 77.9 % of patients. Tinnitus was unilateral in 51 % of patients and had a tonal nature in 45 % of patients. In total, 45.8 % of patients with high-frequency sensorineural hearing loss had high-pitched tinnitus. There were significant correlations between tinnitus severity, loudness and annoyance. Correlations with THI (Tinnitus Handicap Inventory) and Beck depression index scores were also found. Sensorineural tinnitus was related with hearing loss in some frequencies nevertheless of patients' own awareness of hearing loss. Loudness and annoyance of tinnitus seems to be two important factors reflecting psychological problems of patients' stress and depression.
Evaluation of patients with gastric polyps.
Olmez, Sehmus; Sayar, Suleyman; Saritas, Bunyamin; Savas, Ayla Yildiz; Avcioglu, Ufuk; Tenlik, Ilyas; Ozaslan, Ersan; Koseoglu, Hasan Tankut; Altiparmak, Emin
2018-01-01
The incidence of gastric polyps (GPs) greatly differs according to study populations and was found to be 0.33%-6.7% in various studies. The majority of GPs are composed of hyperplastic polyps (HPs), fundic gland polyps (FGPs), and adenomatous polyps (APs). Although APs have a high risk of malignant potential, sporadic FGPs have no malignant potential. Conversely, HPs have a low risk of malignant potential. It is not sufficient to perform a biopsy to identify the polyp type and the presence of dysplasia; thus, some polyps may require multiple biopsies or total excision. This retrospective study included patients with GPs or polypoid lesions found on esophagogastroscopy with polyp or malignant histology on biopsy at Ankara Numune Training and Research Hospital Endoscopy Unit between 2005 and 2011. In a series of 56.300 upper endoscopies, 192 patients (0.34%) were found to have GPs. Among the patients, 51 (26.6%) were men and 151 (73.4%) were women. The average age of the patients was 61.9±13.3 (14-90) years. The frequency of HPs, APs, and FGPs were 88%, 2.6%, and 1.6%, respectively. The size of the polyps was ≤1 cm in 137 (70%) patients. One polyp was determined in 141 (73.4%) patients. The most common localizations of polyps were the antrum and corpus. Endoscopic snare polypectomy was performed in 64 patients. One bleeding episode was observed, which required endoscopic treatment after ESP. In our study, the GP frequency was low (0.34%), whereas the frequency of HP maybe high due to the high frequency of Helicobacter pylori (HPy) infection in our country. The frequency of FGP is probably low due to the high frequency of HPy infection and the short-term use of proton-pump inhibitors.
NASA Astrophysics Data System (ADS)
Wei, Kai; Wang, Feng; Wang, Ping; Liu, Zi-xuan; Zhang, Pan
2017-03-01
The soft under baseplate pad of WJ-8 rail fastener frequently used in China's high-speed railways was taken as the study subject, and a laboratory test was performed to measure its temperature and frequency-dependent dynamic performance at 0.3 Hz and at -60°C to 20°C with intervals of 2.5°C. Its higher frequency-dependent results at different temperatures were then further predicted based on the time-temperature superposition (TTS) and Williams-Landel-Ferry (WLF) formula. The fractional derivative Kelvin-Voigt (FDKV) model was used to represent the temperature- and frequency-dependent dynamic properties of the tested rail pad. By means of the FDKV model for rail pads and vehicle-track coupled dynamic theory, high-speed vehicle-track coupled vibrations due to temperature- and frequency-dependent dynamic properties of rail pads was investigated. Finally, further combining with the measured frequency-dependent dynamic performance of vehicle's rubber primary suspension, the high-speed vehicle-track coupled vibration responses were discussed. It is found that the storage stiffness and loss factor of the tested rail pad are sensitive to low temperatures or high frequencies. The proposed FDKV model for the frequency-dependent storage stiffness and loss factors of the tested rail pad can basically meet the fitting precision, especially at ordinary temperatures. The numerical simulation results indicate that the vertical vibration levels of high-speed vehicle-track coupled systems calculated with the FDKV model for rail pads in time domain are higher than those calculated with the ordinary Kelvin-Voigt (KV) model for rail pads. Additionally, the temperature- and frequency-dependent dynamic properties of the tested rail pads would alter the vertical vibration acceleration levels (VALs) of the car body and bogie in 1/3 octave frequencies above 31.5 Hz, especially enlarge the vertical VALs of the wheel set and rail in 1/3 octave frequencies of 31.5-100 Hz and above 315 Hz, which are the dominant frequencies of ground vibration acceleration and rolling noise (or bridge noise) caused by high-speed railways respectively. Since the fractional derivative value of the adopted rubber primary suspension, unlike the tested rail pad, is very close to 1, its frequency-dependent dynamic performance has little effect on high-speed vehicle-track coupled vibration responses.
Mikstiene, Violeta; Jakaitiene, Audrone; Byckova, Jekaterina; Gradauskiene, Egle; Preiksaitiene, Egle; Burnyte, Birute; Tumiene, Birute; Matuleviciene, Ausra; Ambrozaityte, Laima; Uktveryte, Ingrida; Domarkiene, Ingrida; Rancelis, Tautvydas; Cimbalistiene, Loreta; Lesinskas, Eugenijus; Kucinskas, Vaidutis; Utkus, Algirdas
2016-02-19
Congenital hearing loss (CHL) is diagnosed in 1 - 2 newborns in 1000, genetic factors contribute to two thirds of CHL cases in industrialised countries. Mutations of the GJB2 gene located in the DFNB1 locus (13q11-12) are a major cause of CHL worldwide. The aim of this cross-sectional study was to assess the contribution of the DFNB1 locus containing the GJB2 and GJB6 genes in the development of early onset hearing loss in the affected group of participants, to determine the population-specific mutational profile and DFNB1-related HL burden in Lithuanian population. Clinical data were obtained from a collection of 158 affected participants (146 unrelated probands) with early onset non-syndromic HL. GJB2 and GJB6 gene sequencing and GJB6 gene deletion testing were performed. The data of GJB2 and GJB6 gene sequencing in 98 participants in group of self-reported healthy Lithuanian inhabitants were analysed. Statistic summary, homogeneity tests, and logistic regression analysis were used for the assessment of genotype-phenotype correlation. Our findings show 57.5% of affected participants with two pathogenic GJB2 gene mutations identified. The most prevalent GJB2 mutations were c.35delG, p. (Gly12Valfs*2) (rs80338939) and c.313_326del14, p. (Lys105Glyfs*5) (rs111033253) with allele frequencies 64.7% and 28.3% respectively. GJB6 gene mutations were not identified in the affected group of participants. The statistical analysis revealed significant differences between GJB2(-) and GJB2(+) groups in disease severity (p = 0.001), and family history (p = 0.01). The probability of identification of GJB2 mutations in patients with various HL characteristics was estimated. The carrier rate of GJB2 gene mutations - 7.1% (~1 in 14) was identified in the group of healthy participants and a high frequency of GJB2-related hearing loss was estimated in our population. The results show a very high proportion of GJB2-positive individuals in the research group affected with sensorineural HL. The allele frequency of c.35delG mutation (64.7 %) is consistent with many previously published studies in groups of affected individuals of Caucasian populations. The high frequency of the c.313_326del14 (28.3 % of pathogenic alleles) mutation in affected group of participants was an unexpected finding in our study suggesting not only a high frequency of carriers of this mutation in our population but also its possible origin in Lithuanian ancestors. The high frequency of carriers of the c.313_326del14 mutation in the entire Lithuanian population is supported by it being identified twice in the ethnic Lithuanian group of healthy participants (a frequency 2.0 % of carriers in the study group). Analysis of the allele frequency of GJB2 gene mutations revealed a high proportion of c. 313_326del14 (rs111033253) mutations in the GJB2-positive group suggesting its possible origin in Lithuanian forebears. The high frequency of carriers of GJB2 gene mutations in the group of healthy participants corresponds to the substantial frequency of GJB2-associated HL in Lithuania. The observations of the study indicate the significant contribution of GJB2 gene mutations to the pathogenesis of the disorder in the Lithuanian population and will contribute to introducing principles to predict the characteristics of the disease in patients.
Parametric Effects of Word Frequency in Memory for Mixed Frequency Lists
ERIC Educational Resources Information Center
Lohnas, Lynn J.; Kahana, Michael J.
2013-01-01
The "word frequency paradox" refers to the finding that low frequency words are better recognized than high frequency words yet high frequency words are better recalled than low frequency words. Rather than comparing separate groups of low and high frequency words, we sought to quantify the functional relation between word frequency and…
Rhodes-Mordov, Elisheva; Katz, Ben; Oberegelsbacher, Claudia; Yasin, Bushra; Tzadok, Hanan; Huber, Armin
2017-01-01
Drosophila photoreceptors respond to oscillating light of high frequency (∼100 Hz), while the detected maximal frequency is modulated by the light rearing conditions, thus enabling high sensitivity to light and high temporal resolution. However, the molecular basis for this adaptive process is unclear. Here, we report that dephosphorylation of the light-activated transient receptor potential (TRP) ion channel at S936 is a fast, graded, light-dependent, and Ca2+-dependent process that is partially modulated by the rhodopsin phosphatase retinal degeneration C (RDGC). Electroretinogram measurements of the frequency response to oscillating lights in vivo revealed that dark-reared flies expressing wild-type TRP exhibited a detection limit of oscillating light at relatively low frequencies, which was shifted to higher frequencies upon light adaptation. Strikingly, preventing phosphorylation of the S936-TRP site by alanine substitution in transgenic Drosophila (trpS936A) abolished the difference in frequency response between dark-adapted and light-adapted flies, resulting in high-frequency response also in dark-adapted flies. In contrast, inserting a phosphomimetic mutation by substituting the S936-TRP site to aspartic acid (trpS936D) set the frequency response of light-adapted flies to low frequencies typical of dark-adapted flies. Light-adapted rdgC mutant flies showed relatively high S936-TRP phosphorylation levels and light–dark phosphorylation dynamics. These findings suggest that RDGC is one but not the only phosphatase involved in pS936-TRP dephosphorylation. Together, this study indicates that TRP channel dephosphorylation is a regulatory process that affects the detection limit of oscillating light according to the light rearing condition, thus adjusting dynamic processing of visual information under varying light conditions. SIGNIFICANCE STATEMENT Drosophila photoreceptors exhibit high temporal resolution as manifested in frequency response to oscillating light of high frequency (≤∼100 Hz). Light rearing conditions modulate the maximal frequency detected by photoreceptors, thus enabling them to maintain high sensitivity to light and high temporal resolution. However, the precise mechanisms for this process are not fully understood. Here, we show by combination of biochemistry and in vivo electrophysiology that transient receptor potential (TRP) channel dephosphorylation at a specific site is a fast, light-activated and Ca2+-dependent regulatory process. TRP dephosphorylation affects the detection limit of oscillating light according to the adaptation state of the photoreceptor cells by shifting the detection limit to higher frequencies upon light adaptation. This novel mechanism thus adjusts dynamic processing of visual information under varying light conditions. PMID:28314815
Mizukami, Keijiro; Yabuki, Akira; Chang, Hye-Sook; Uddin, Mohammad Mejbah; Rahman, Mohammad Mahbubur; Kushida, Kazuya; Kohyama, Moeko; Yamato, Osamu
2013-01-01
A single nucleotide substitution (c.-6-180T>G) associated with resistance to phenobarbital therapy has been found in the canine MDR1/ABCB1 gene in Border Collies with idiopathic epilepsy. In the present study, a PCR-restriction fragment length polymorphism assay was developed for genotyping this mutation, and a genotyping survey was carried out in a population of 472 Border Collies in Japan to determine the current allele frequency. The survey demonstrated the frequencies of the T/T wild type, T/G heterozygote, and G/G mutant homozygote to be 60.0%, 30.3%, and 9.8%, respectively, indicating that the frequency of the mutant G allele is extremely high (24.9%) in Border Collies. The results suggest that this high mutation frequency of the mutation is likely to cause a high prevalence of phenobarbital-resistant epilepsy in Border Collies.
Mizukami, Keijiro; Yabuki, Akira; Chang, Hye-Sook; Uddin, Mohammad Mejbah; Rahman, Mohammad Mahbubur; Kushida, Kazuya; Kohyama, Moeko
2013-01-01
A single nucleotide substitution (c.-6-180T>G) associated with resistance to phenobarbital therapy has been found in the canine MDR1/ABCB1 gene in Border Collies with idiopathic epilepsy. In the present study, a PCR-restriction fragment length polymorphism assay was developed for genotyping this mutation, and a genotyping survey was carried out in a population of 472 Border Collies in Japan to determine the current allele frequency. The survey demonstrated the frequencies of the T/T wild type, T/G heterozygote, and G/G mutant homozygote to be 60.0%, 30.3%, and 9.8%, respectively, indicating that the frequency of the mutant G allele is extremely high (24.9%) in Border Collies. The results suggest that this high mutation frequency of the mutation is likely to cause a high prevalence of phenobarbital-resistant epilepsy in Border Collies. PMID:24302812
High-frequency neural oscillations and visual processing deficits in schizophrenia
Tan, Heng-Ru May; Lana, Luiz; Uhlhaas, Peter J.
2013-01-01
Visual information is fundamental to how we understand our environment, make predictions, and interact with others. Recent research has underscored the importance of visuo-perceptual dysfunctions for cognitive deficits and pathophysiological processes in schizophrenia. In the current paper, we review evidence for the relevance of high frequency (beta/gamma) oscillations towards visuo-perceptual dysfunctions in schizophrenia. In the first part of the paper, we examine the relationship between beta/gamma band oscillations and visual processing during normal brain functioning. We then summarize EEG/MEG-studies which demonstrate reduced amplitude and synchrony of high-frequency activity during visual stimulation in schizophrenia. In the final part of the paper, we identify neurobiological correlates as well as offer perspectives for future research to stimulate further inquiry into the role of high-frequency oscillations in visual processing impairments in the disorder. PMID:24130535
Janssen, Paddy K C; Olivier, Berend; Zwinderman, Aeilko H; Waldinger, Marcel D
2014-01-01
To analyze a recently published meta-analysis of six studies on 5-HTTLPR polymorphism and lifelong premature ejaculation (PE). Calculation of fraction observed and expected genotype frequencies and Hardy Weinberg equilibrium (HWE) of cases and controls. LL,SL and SS genotype frequencies of patients were subtracted from genotype frequencies of an ideal population (LL25%, SL50%, SS25%, p = 1 for HWE). Analysis of PCRs of six studies and re-analysis of the analysis and Odds ratios (ORs) reported in the recently published meta-analysis. Three studies deviated from HWE in patients and one study deviated from HWE in controls. In three studies in-HWE the mean deviation of genotype frequencies from a theoretical population not-deviating from HWE was small: LL(1.7%), SL(-2.3%), SS(0.6%). In three studies not-in-HWE the mean deviation of genotype frequencies was high: LL(-3.3%), SL(-18.5%) and SS(21.8%) with very low percentage SL genotype concurrent with very high percentage SS genotype. The most serious PCR deviations were reported in the three not-in-HWE studies. The three in-HWE studies had normal OR. In contrast, the three not-in-HWE studies had a low OR. In three studies not-in-HWE and with very low OR, inadequate PCR analysis and/or inadequate interpretation of its gel electrophoresis resulted in very low SL and a resulting shift to very high SS genotype frequency outcome. Consequently, PCRs of these three studies are not reliable. Failure to note the inadequacy of PCR tests makes such PCRs a confounding factor in clinical interpretation of genetic studies. Currently, a meta-analysis can only be performed on three studies-in-HWE. However, based on the three studies-in-HWE with OR of about 1 there is not any indication that in men with lifelong PE the frequency of LL,SL and SS genotype deviates from the general male population and/or that the SL or SS genotype is in any way associated with lifelong PE.
Skarstein, Siv; Rosvold, Elin O; Helseth, Sølvi; Kvarme, Lisbeth G; Holager, Tanja; Småstuen, Milada C; Lagerløv, Per
2014-03-01
To examine characteristics of 15- to 16-year-old adolescents who used over-the-counter analgesics daily to weekly (high-frequency users) as compared to those who used less or no analgesics (low-frequency users). Further to analyse the differences in pain experience, lifestyle, self-esteem, school attendance and educational ambition. An anonymous cross-sectional questionnaire-based study. The questionnaire covered the use of over-the-counter analgesics, pain experience, sociodemographics, lifestyle factors, self-esteem, school absence and future educational plans. The study took place in the 10th grade in six junior high schools in a medium-sized town in Norway. The local sales data for analgesics and antipyretics were close to the national average. We invited 626 adolescents to participate. Of the 367 adolescents (59%) who responded, 51% were girls. Associations between the frequency of use of over-the-counter analgesic and the mentioned variables were analysed using multiple logistic regression. In total, 26% (42 boys and 48 girls) used over-the-counter analgesics daily to weekly. These high-frequency users experienced more widespread pain, slept less, had more paid spare-time work, drank more caffeinated drinks, participated more often in binge drinking, had lower self-esteem, less ambitious educational plans and more frequent school absence than did the low-frequency users. These associations remained significant when controlling for gender, cultural background and self-evaluated economic status. Adolescent, who are high-frequency users of over-the-counter analgesics, suffer more pain and have identifiable characteristics indicative of complex problems. Their ability to handle stress appears to be discordant with the kind of situations to which they are exposed. The wear and tear associated with allostatic mechanisms counteracting stress may heighten their pain experience. © 2013 Nordic College of Caring Science. Published by Blackwell Publishing Ltd.
Seitner, Maximilian J; Abdi, Mehdi; Ridolfo, Alessandro; Hartmann, Michael J; Weig, Eva M
2017-06-23
We study locking phenomena of two strongly coupled, high quality factor nanomechanical resonator modes to a common parametric drive at a single drive frequency in different parametric driving regimes. By controlled dielectric gradient forces we tune the resonance frequencies of the flexural in-plane and out-of-plane oscillation of the high stress silicon nitride string through their mutual avoided crossing. For the case of the strong common parametric drive signal-idler generation via nondegenerate parametric two-mode oscillation is observed. Broadband frequency tuning of the very narrow linewidth signal and idler resonances is demonstrated. When the resonance frequencies of the signal and idler get closer to each other, partial injection locking, injection pulling, and complete injection locking to half of the drive frequency occurs depending on the pump strength. Furthermore, satellite resonances, symmetrically offset from the signal and idler by their beat note, are observed, which can be attributed to degenerate four-wave mixing in the highly nonlinear mechanical oscillations.
Quantum-limited detection of millimeter waves using superconducting tunnel junctions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mears, Carl Atherton
1991-09-01
The quasiparticle tunneling current in a superconductor-insulator- superconductor (SIS) tunnel junction is highly nonlinear. Such a nonlinearity can be used to mix two millimeter wave signals to produce a signal at a much lower intermediate frequency. We have constructed several millimeter and sub-millimeter wave SIS mixers in order to study high frequency response of the quasiparticle tunneling current and the physics of high frequency mixing. We have made the first measurement of the out-of-phase tunneling currents in an SIS tunnel junction. We have developed a method that allows us to determine the parameters of the high frequency embedding circuit bymore » studying the details of the pumped I-V curve. We have constructed a 80--110 GHz waveguide-based mixer test apparatus that allows us to accurately measure the gain and added noise of the SIS mixer under test. Using extremely high quality tunnel junctions, we have measured an added mixer noise of 0.61 ± 0.36 quanta, which is within 25 percent of the quantum limit imposed by the Heisenberg uncertainty principle. This measured performance is in excellent agreement with that predicted by Tucker`s theory of quantum mixing. We have also studied quasioptically coupled millimeter- and submillimeter-wave mixers using several types of integrated tuning elements. 83 refs.« less
Quantum-limited detection of millimeter waves using superconducting tunnel junctions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mears, C.A.
1991-09-01
The quasiparticle tunneling current in a superconductor-insulator- superconductor (SIS) tunnel junction is highly nonlinear. Such a nonlinearity can be used to mix two millimeter wave signals to produce a signal at a much lower intermediate frequency. We have constructed several millimeter and sub-millimeter wave SIS mixers in order to study high frequency response of the quasiparticle tunneling current and the physics of high frequency mixing. We have made the first measurement of the out-of-phase tunneling currents in an SIS tunnel junction. We have developed a method that allows us to determine the parameters of the high frequency embedding circuit bymore » studying the details of the pumped I-V curve. We have constructed a 80--110 GHz waveguide-based mixer test apparatus that allows us to accurately measure the gain and added noise of the SIS mixer under test. Using extremely high quality tunnel junctions, we have measured an added mixer noise of 0.61 {plus minus} 0.36 quanta, which is within 25 percent of the quantum limit imposed by the Heisenberg uncertainty principle. This measured performance is in excellent agreement with that predicted by Tucker's theory of quantum mixing. We have also studied quasioptically coupled millimeter- and submillimeter-wave mixers using several types of integrated tuning elements. 83 refs.« less
He, Wenxuan; Porsov, Edward; Kemp, David; Nuttall, Alfred L.; Ren, Tianying
2012-01-01
Background It is commonly assumed that the cochlear microphonic potential (CM) recorded from the round window (RW) is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. Methodology/Principal Findings This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. Conclusions/Significance We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases. PMID:22470560
Rohan, Annie J
2015-01-01
To study infant factors, characteristics of pain scores, and analgesic practices associated with patient-days in the NICU with a high frequency of pain-associated procedures (defined as >10 pain-associated procedures in the day). This is a secondary analysis of data from a cross-sectional study that used medical record audits of premature, ventilated infants. The primary two-institution study yielded data for 196 patient-days. Data included 804 pain scores and 836 pain-associated procedures. A high frequency of pain-associated procedures occurred in 8% of days at Site A and in 25% of days at Site B. Prevalence of days with high frequency of pain-associated procedures differed by institution, and was higher at the institution where infants were more mature at birth and had fewer surgical procedures. High frequency of pain-associated procedures was related to endotracheal intubation at both institutions. There were no elevated pain scores and no documented analgesic administrations on days with over 20 pain-associated procedures. High exposure to pain-associated procedures during a 24-hour period for a premature, ventilated infant is rarely associated with elevated pain scores or analgesic administration. Prevalence of days with high-procedural exposure at an institution appears to be closely related to use of invasive ventilation and to individual institutional practices. Examination and discussion of the daily frequency of pain-associated procedures for premature, ventilated infants (especially for those receiving invasive ventilation) may be helpful in developing approaches for attenuating the cumulative pain experience for these babies. Resources that are expended on regular pain reassessment documentation processes in the NICU may need to be reconsidered in light of the very low yield for clinical alterations in care in this setting.
A study of the high-frequency hearing thresholds of dentistry professionals
Lopes, Andréa Cintra; de Melo, Ana Dolores Passarelli; Santos, Cibele Carmelo
2012-01-01
Summary Introduction: In the dentistry practice, dentists are exposed to harmful effects caused by several factors, such as the noise produced by their work instruments. In 1959, the American Dental Association recommended periodical hearing assessments and the use of ear protectors. Aquiring more information regarding dentists', dental nurses', and prosthodontists' hearing abilities is necessary to propose prevention measures and early treatment strategies. Objective: To investigate the auditory thresholds of dentists, dental nurses, and prosthodontists. Method: In this clinical and experimental study, 44 dentists (Group I; GI), 36 dental nurses (Group II; GII), and 28 prosthodontists (Group III; GIII) were included, , with a total of 108 professionals. The procedures that were performed included a specific interview, ear canal inspection, conventional and high-frequency threshold audiometry, a speech reception threshold test, and an acoustic impedance test. Results: In the 3 groups that were tested, the comparison between the mean hearing thresholds provided evidence of worsened hearing ability relative to the increase in frequency. For the tritonal mean at 500 to 2,000 Hz and 3,000 to 6,000 Hz, GIII presented the worst thresholds. For the mean of the high frequencies (9,000 and 16,000 Hz), GII presented the worst thresholds. Conclusion: The conventional hearing threshold evaluation did not demonstrate alterations in the 3 groups that were tested; however, the complementary tests such as high-frequency audiometry provided greater efficacy in the early detection of hearing problems, since this population's hearing loss impaired hearing ability at frequencies that are not tested by the conventional tests. Therefore, we emphasize the need of utilizing high-frequency threshold audiometry in the hearing assessment routine in combination with other audiological tests. PMID:25991940
Shibasaki, Koji; Ogawa, Sumito; Yamada, Shizuru; Ouchi, Yasuyoshi; Akishita, Masahiro
2018-04-11
Previous studies have shown the relationship between low blood pressure and high mortality in frail, disabled older adults in long-term care. However, the mechanism of this relationship is still unclear. We hypothesized that autonomic nervous activity decline is involved in the relationship between low blood pressure and high mortality. The present prospective cohort study recruited 61 participants aged ≥75 years. The data from 24-h Holter monitoring and blood pressure recorded by ambulatory blood pressure monitoring were collected. Measured data were divided into three categories: 24-h, daytime and night-time. From power spectral density in the electrocardiogram, low frequency, high frequency and low frequency/high frequency ratio were calculated. The primary end-point was death. High blood pressure was connected to both high daytime low frequency and high frequency (partial correlation coefficients: 0.42, P < 0.05 and 0.35, P < 0.05, respectively). In addition, the low blood pressure group had higher mortality than the high blood pressure group, and disabled older adults in long-term care and those with elevated daytime systolic and diastolic blood pressure had less risk of mortality compared with those without (systolic: hazard ratio 0.89, 95% confidence interval 0.83-0.96, P = 0.003; diastolic: hazard ratio 0.98, 95% confidence interval 0.79-1.00, P = 0.049). The average blood pressures in the high blood pressure groups were approximately 140/80 mmHg and were connected to low mortality. Attenuated autonomic nervous activity might lead to low blood pressure in the daytime and high mortality in disabled older adults in long-term care. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 Japan Geriatrics Society.
Antenna design for propagating spin wave spectroscopy in ferromagnetic thin films
NASA Astrophysics Data System (ADS)
Zhang, Yan; Yu, Ting; Chen, Ji-lei; Zhang, You-guang; Feng, Jian; Tu, Sa; Yu, Haiming
2018-03-01
In this paper, we investigate the characteristics of antenna for propagating-spin-wave-spectroscopy (PSWS) experiment in ferromagnetic thin films. Firstly, we simulate the amplitude and phase distribution of the high-frequency magnetic field around antenna by high frequency structure simulator (HFSS). And then k distribution of the antenna is obtained by fast Fourier transformation (FFT). Furthermore, three kinds of antenna designs, i.e. micro-strip line, coplanar waveguide (CPW), loop, are studied and compared. How the dimension parameter of antenna influence the corresponding high-frequency magnetic field amplitude and k distribution are investigated in details.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
Anthropogenic activities, such as dam operations, often induce larger and more frequent stage fluctuations than those occurring in natural rivers. However, the long-term impact of such flow variations on thermal and biogeochemical dynamics of the associated hyporheic zone (HZ) is poorly understood. A heterogeneous, two-dimensional thermo-hydro-biogeochemical model revealed an important interaction between high-frequency flow variations and watershed-scale hydrology. High-frequency stage fluctuations had their strongest thermal and biogeochemical impacts when the mean river stage was low during fall and winter. An abnormally thin snowpack in 2015, however, created a low river stage during summer and early fall, whereby high frequency stagemore » fluctuations caused the HZ to be warmer than usual. This study provided the scientific basis to assess the potential ecological consequences of the high-frequency flow variations in a regulated river, as well as guidance on how to maximize the potential benefits—or minimize the drawbacks—of river regulation to river ecosystems.« less
Parametric array technique for microbubble excitation.
Vos, Hendrik J; Goertz, David E; van der Steen, Antonius F W; de Jong, Nico
2011-05-01
This study investigates the use of an acoustic parametric array as a means for microbubble excitation. The excitation wave is generated during propagation in a nonlinear medium of two high-frequency carrier waves, whereby the frequency of the excitation wave is the difference frequency of the carrier waves. Carrier waves of around 10 and 25 MHz are used to generate low-frequency waves between 0.5 and 3.5 MHz at amplitudes in the range of 25 to 80 kPa in water. We demonstrate with high-speed camera observations that it is possible to induce microbubble oscillations with the low frequency signal arising from the nonlinear propagation process. As an application, we determined the resonance frequency of Definity contrast agent microbubbles with radius ranging from 1.5 to 5 μm by sweeping the difference frequency in the range from 0.5 to 3.5 MHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Yu; Che, Yuchi; Zhou, Chongwu, E-mail: chongwuz@usc.edu
In this paper, we report the high-performance radio-frequency transistors based on the single-walled semiconducting carbon nanotubes with a refined average diameter of ∼1.6 nm. These diameter-separated carbon nanotube transistors show excellent transconductance of 55 μS/μm and desirable drain current saturation with an output resistance of ∼100 KΩ μm. An exceptional radio-frequency performance is also achieved with current gain and power gain cut-off frequencies of 23 GHz and 20 GHz (extrinsic) and 65 GHz and 35 GHz (intrinsic), respectively. These radio-frequency metrics are among the highest reported for the carbon nanotube thin-film transistors. This study provides demonstration of radio frequency transistors based on carbon nanotubes with tailoredmore » diameter distributions, which will guide the future application of carbon nanotubes in radio-frequency electronics.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-16
...; high-pitched sounds contain high frequencies and low-pitched sounds contain low frequencies. Natural... estimated to occur between approximately 150 Hz and 160 kHz. High-frequency cetaceans (eight species of true... masking by high frequency sound. Human data indicate low-frequency sound can mask high-frequency sounds (i...
Keihani, Ahmadreza; Shirzhiyan, Zahra; Farahi, Morteza; Shamsi, Elham; Mahnam, Amin; Makkiabadi, Bahador; Haidari, Mohsen R.; Jafari, Amir H.
2018-01-01
Background: Recent EEG-SSVEP signal based BCI studies have used high frequency square pulse visual stimuli to reduce subjective fatigue. However, the effect of total harmonic distortion (THD) has not been considered. Compared to CRT and LCD monitors, LED screen displays high-frequency wave with better refresh rate. In this study, we present high frequency sine wave simple and rhythmic patterns with low THD rate by LED to analyze SSVEP responses and evaluate subjective fatigue in normal subjects. Materials and Methods: We used patterns of 3-sequence high-frequency sine waves (25, 30, and 35 Hz) to design our visual stimuli. Nine stimuli patterns, 3 simple (repetition of each of above 3 frequencies e.g., P25-25-25) and 6 rhythmic (all of the frequencies in 6 different sequences e.g., P25-30-35) were chosen. A hardware setup with low THD rate (<0.1%) was designed to present these patterns on LED. Twenty two normal subjects (aged 23–30 (25 ± 2.1) yrs) were enrolled. Visual analog scale (VAS) was used for subjective fatigue evaluation after presentation of each stimulus pattern. PSD, CCA, and LASSO methods were employed to analyze SSVEP responses. The data including SSVEP features and fatigue rate for different visual stimuli patterns were statistically evaluated. Results: All 9 visual stimuli patterns elicited SSVEP responses. Overall, obtained accuracy rates were 88.35% for PSD and > 90% for CCA and LASSO (for TWs > 1 s). High frequency rhythmic patterns group with low THD rate showed higher accuracy rate (99.24%) than simple patterns group (98.48%). Repeated measure ANOVA showed significant difference between rhythmic pattern features (P < 0.0005). Overall, there was no significant difference between the VAS of rhythmic [3.85 ± 2.13] compared to the simple patterns group [3.96 ± 2.21], (P = 0.63). Rhythmic group had lower within group VAS variation (min = P25-30-35 [2.90 ± 2.45], max = P35-25-30 [4.81 ± 2.65]) as well as least individual pattern VAS (P25-30-35). Discussion and Conclusion: Overall, rhythmic and simple pattern groups had higher and similar accuracy rates. Rhythmic stimuli patterns showed insignificantly lower fatigue rate than simple patterns. We conclude that both rhythmic and simple visual high frequency sine wave stimuli require further research for human subject SSVEP-BCI studies. PMID:29892219
Keihani, Ahmadreza; Shirzhiyan, Zahra; Farahi, Morteza; Shamsi, Elham; Mahnam, Amin; Makkiabadi, Bahador; Haidari, Mohsen R; Jafari, Amir H
2018-01-01
Background: Recent EEG-SSVEP signal based BCI studies have used high frequency square pulse visual stimuli to reduce subjective fatigue. However, the effect of total harmonic distortion (THD) has not been considered. Compared to CRT and LCD monitors, LED screen displays high-frequency wave with better refresh rate. In this study, we present high frequency sine wave simple and rhythmic patterns with low THD rate by LED to analyze SSVEP responses and evaluate subjective fatigue in normal subjects. Materials and Methods: We used patterns of 3-sequence high-frequency sine waves (25, 30, and 35 Hz) to design our visual stimuli. Nine stimuli patterns, 3 simple (repetition of each of above 3 frequencies e.g., P25-25-25) and 6 rhythmic (all of the frequencies in 6 different sequences e.g., P25-30-35) were chosen. A hardware setup with low THD rate (<0.1%) was designed to present these patterns on LED. Twenty two normal subjects (aged 23-30 (25 ± 2.1) yrs) were enrolled. Visual analog scale (VAS) was used for subjective fatigue evaluation after presentation of each stimulus pattern. PSD, CCA, and LASSO methods were employed to analyze SSVEP responses. The data including SSVEP features and fatigue rate for different visual stimuli patterns were statistically evaluated. Results: All 9 visual stimuli patterns elicited SSVEP responses. Overall, obtained accuracy rates were 88.35% for PSD and > 90% for CCA and LASSO (for TWs > 1 s). High frequency rhythmic patterns group with low THD rate showed higher accuracy rate (99.24%) than simple patterns group (98.48%). Repeated measure ANOVA showed significant difference between rhythmic pattern features ( P < 0.0005). Overall, there was no significant difference between the VAS of rhythmic [3.85 ± 2.13] compared to the simple patterns group [3.96 ± 2.21], ( P = 0.63). Rhythmic group had lower within group VAS variation (min = P25-30-35 [2.90 ± 2.45], max = P35-25-30 [4.81 ± 2.65]) as well as least individual pattern VAS (P25-30-35). Discussion and Conclusion: Overall, rhythmic and simple pattern groups had higher and similar accuracy rates. Rhythmic stimuli patterns showed insignificantly lower fatigue rate than simple patterns. We conclude that both rhythmic and simple visual high frequency sine wave stimuli require further research for human subject SSVEP-BCI studies.
Analysis of propellant feedline dynamics
NASA Technical Reports Server (NTRS)
Astleford, W. J.; Holster, J. L.; Gerlach, C. R.
1972-01-01
An analytical model and computer program were developed for studying the disturbances of liquid propellants in engine feedline systems. It was found that the predominant effect of turbulence is to increase the spatial attenuation at low frequencies; at high frequencies the laminar and turbulent frequencies coincide. Recommendations for future work are included.
Moore, Brian C J
2012-09-01
This article reviews a series of studies on the factors influencing sound quality preferences, mostly for jazz and classical music stimuli. The data were obtained using ratings of individual stimuli or using the method of paired comparisons. For normal-hearing participants, the highest ratings of sound quality were obtained when the reproduction bandwidth was wide (55 to 16000 Hz) and ripples in the frequency response were small (less than ± 5 dB). For hearing-impaired participants listening via a simulated five-channel compression hearing aid with gains set using the CAM2 fitting method, preferences for upper cutoff frequency varied across participants: Some preferred a 7.5- or 10-kHz upper cutoff frequency over a 5-kHz cutoff frequency, and some showed the opposite preference. Preferences for a higher upper cutoff frequency were associated with a shallow high-frequency slope of the audiogram. A subsequent study comparing the CAM2 and NAL-NL2 fitting methods, with gains slightly reduced for participants who were not experienced hearing aid users, showed a consistent preference for CAM2. Since the two methods differ mainly in the gain applied for frequencies above 4 kHz (CAM2 recommending higher gain than NAL-NL2), these results suggest that extending the upper cutoff frequency is beneficial. A system for reducing "overshoot" effects produced by compression gave small but significant benefits for sound quality of a percussion instrument (xylophone). For a high-input level (80 dB SPL), slow compression was preferred over fast compression.
Mitt, Mario; Kals, Mart; Pärn, Kalle; Gabriel, Stacey B; Lander, Eric S; Palotie, Aarno; Ripatti, Samuli; Morris, Andrew P; Metspalu, Andres; Esko, Tõnu; Mägi, Reedik; Palta, Priit
2017-06-01
Genetic imputation is a cost-efficient way to improve the power and resolution of genome-wide association (GWA) studies. Current publicly accessible imputation reference panels accurately predict genotypes for common variants with minor allele frequency (MAF)≥5% and low-frequency variants (0.5≤MAF<5%) across diverse populations, but the imputation of rare variation (MAF<0.5%) is still rather limited. In the current study, we evaluate imputation accuracy achieved with reference panels from diverse populations with a population-specific high-coverage (30 ×) whole-genome sequencing (WGS) based reference panel, comprising of 2244 Estonian individuals (0.25% of adult Estonians). Although the Estonian-specific panel contains fewer haplotypes and variants, the imputation confidence and accuracy of imputed low-frequency and rare variants was significantly higher. The results indicate the utility of population-specific reference panels for human genetic studies.
Mitt, Mario; Kals, Mart; Pärn, Kalle; Gabriel, Stacey B; Lander, Eric S; Palotie, Aarno; Ripatti, Samuli; Morris, Andrew P; Metspalu, Andres; Esko, Tõnu; Mägi, Reedik; Palta, Priit
2017-01-01
Genetic imputation is a cost-efficient way to improve the power and resolution of genome-wide association (GWA) studies. Current publicly accessible imputation reference panels accurately predict genotypes for common variants with minor allele frequency (MAF)≥5% and low-frequency variants (0.5≤MAF<5%) across diverse populations, but the imputation of rare variation (MAF<0.5%) is still rather limited. In the current study, we evaluate imputation accuracy achieved with reference panels from diverse populations with a population-specific high-coverage (30 ×) whole-genome sequencing (WGS) based reference panel, comprising of 2244 Estonian individuals (0.25% of adult Estonians). Although the Estonian-specific panel contains fewer haplotypes and variants, the imputation confidence and accuracy of imputed low-frequency and rare variants was significantly higher. The results indicate the utility of population-specific reference panels for human genetic studies. PMID:28401899
In Situ Observations of Harmonic Alfvén Waves and Associated Heavy Ion Heating
NASA Astrophysics Data System (ADS)
Chen, Huayue; Gao, Xinliang; Lu, Quanming; Wang, Shui
2018-06-01
Resonant ion heating by high-frequency Alfvén waves has long been believed to be the primary dissipation mechanism for solar coronal heating, and these high-frequency Alfvén waves are considered to be generated via cascade from low-frequency Alfvén waves. In this study, we report an unusual harmonic Alfvén event from in situ observations by the Van Allen Probes in the magnetosphere, having an environment similar to that in the solar corona. The harmonic Alfvén waves, which propagate almost along the wave vector of the fundamental waves, are considered to be generated due to the interaction between quasi-parallel Alfvén waves and plasma density fluctuations with almost identical frequency. These high-frequency harmonic Alfvén waves can then cyclotron resonantly heat the heavy ions. Our observations provide an important insight into solar corona heating by Alfvén waves.
Je, Yub; Lee, Haksue; Park, Jongkyu; Moon, Wonkyu
2010-06-01
An ultrasonic radiator is developed to generate a difference frequency sound from two frequencies of ultrasound in air with a parametric array. A design method is proposed for an ultrasonic radiator capable of generating highly directive, high-amplitude ultrasonic sound beams at two different frequencies in air based on a modification of the stepped-plate ultrasonic radiator. The stepped-plate ultrasonic radiator was introduced by Gallego-Juarez et al. [Ultrasonics 16, 267-271 (1978)] in their previous study and can effectively generate highly directive, large-amplitude ultrasonic sounds in air, but only at a single frequency. Because parametric array sources must be able to generate sounds at more than one frequency, a design modification is crucial to the application of a stepped-plate ultrasonic radiator as a parametric array source in air. The aforementioned method was employed to design a parametric radiator for use in air. A prototype of this design was constructed and tested to determine whether it could successfully generate a difference frequency sound with a parametric array. The results confirmed that the proposed single small-area transducer was suitable as a parametric radiator in air.
Active Control of High-Speed Free Jets Using High-Frequency Excitation
NASA Astrophysics Data System (ADS)
Upadhyay, Puja
Control of aerodynamic noise generated by high-performance jet engines continues to remain a serious problem for the aviation community. Intense low frequency noise produced by large-scale coherent structures is known to dominate acoustic radiation in the aft angles. A tremendous amount of research effort has been dedicated towards the investigation of many passive and active flow control strategies to attenuate jet noise, while keeping performance penalties to a minimum. Unsteady excitation, an active control technique, seeks to modify acoustic sources in the jet by leveraging the naturally-occurring flow instabilities in the shear layer. While excitation at a lower range of frequencies that scale with the dynamics of large-scale structures, has been attempted by a number of studies, effects at higher excitation frequencies remain severely unexplored. One of the major limitations stems from the lack of appropriate flow control devices that have sufficient dynamic response and/or control authority to be useful in turbulent flows, especially at higher speeds. To this end, the current study seeks to fulfill two main objectives. First, the design and characterization of two high-frequency fluidic actuators (25 and 60 kHz) are undertaken, where the target frequencies are guided by the dynamics of high-speed free jets. Second, the influence of high-frequency forcing on the aeroacoustics of high-speed jets is explored in some detail by implementing the nominally 25 kHz actuator on a Mach 0.9 (Re D = 5 x 105) free jet flow field. Subsequently, these findings are directly compared to the results of steady microjet injection experiments performed in the same rig and to prior jet noise control studies, where available. Finally, limited acoustic measurements were also performed by implementing the nominally 25 kHz actuators on jets at higher Mach numbers, including shock containing jets, and elevated temperatures. Using lumped element modeling as an initial guide, the current work expands on the previous development of low-frequency (2-8 kHz) Resonance Enhanced Micro-actuators (REM) to design actuators that are capable of producing high amplitude pulses at much higher frequencies. Extensive benchtop characterization, using acoustic measurements as well as optical diagnostics using a high resolution micro-schlieren setup, is employed to characterize the flow properties and dynamic response of these actuators. The actuators produced high-amplitude output a range of frequencies, 20.3-27.8 kHz and 54.8-78.2 kHz, respectively. In addition to providing information on the actuator flow physics and performances at various operating conditions, the benchtop study serves to develop relatively easy-to-integrate, high-frequency actuators for active control of high-speed jets for noise reduction. Following actuator characterization studies, the nominally 25 kHz ( StDF ≈ 2.2) actuators are implemented on a Mach 0.9 free jet flow field. Eight actuators are azimuthally distributed at the nozzle exit to excite the initial shear layer at frequencies that are approximately an order of magnitude higher compared to the jet preferred frequency, StP ≈ 0.2-0.3. The influence of control on the mean and turbulent characteristics of the jet, especially the developing shear layer, is examined in great detail using planar and stereoscopic Particle Image Velocimetry (PIV). Examination of cross-stream velocity profiles revealed that actuation leads to strong, spatially coherent streamwise vortex pairs which in turn significantly modify the mean flow field, resulting in a prominently undulated shear layer. These vortices grow as they convect downstream, enhancing local entrainment and significantly thickening the initial shear layer. Azimuthal inhomogeneity introduced in the jet shear layer is also evident in the simultaneous redistribution and reduction of peak turbulent fluctuations in the cross-plane near the nozzle exit. Further downstream, control results in a global suppression of turbulence intensities for all axial locations, also evidenced by a longer potential core and overall reduced jet spreading. The resulting impact on the noise signature is estimated via far-field acoustic measurements. Noise reduction was observed at low to moderate frequencies for all observation angles. Direct comparison of these results with that of steady microjet injection revealed some notable differences in the initial development of streamwise vorticity and the redistribution of peak turbulence in the azimuthal direction. However, despite significant differences in the near nozzle aerodynamics, the downstream evolution of the jet appeared to approach near similar conditions with both high-frequency and steady microjet injection. Moreover, the impact on far-field noise was also comparable between the two injection methods as well as with others reported in the literature. Finally, for jets at higher Mach numbers and elevated temperatures, the effect of control was observed to vary with jet conditions. While the impact of the two control mechanisms were fairly comparable on non-shock containing jets, high-frequency forcing was observed to produce significantly larger reductions in screech and broadband shock-associated noise (BBSN) at select under-expanded jet conditions. The observed variations in control effects at different jet conditions call for further investigation.
A model for studying the energetics of sustained high frequency firing
Morris, Catherine E.
2018-01-01
Regulating membrane potential and synaptic function contributes significantly to the energetic costs of brain signaling, but the relative costs of action potentials (APs) and synaptic transmission during high-frequency firing are unknown. The continuous high-frequency (200-600Hz) electric organ discharge (EOD) of Eigenmannia, a weakly electric fish, underlies its electrosensing and communication. EODs reflect APs fired by the muscle-derived electrocytes of the electric organ (EO). Cholinergic synapses at the excitable posterior membranes of the elongated electrocytes control AP frequency. Based on whole-fish O2 consumption, ATP demand per EOD-linked AP increases exponentially with AP frequency. Continual EOD-AP generation implies first, that ion homeostatic processes reliably counteract any dissipation of posterior membrane ENa and EK and second that high frequency synaptic activation is reliably supported. Both of these processes require energy. To facilitate an exploration of the expected energy demands of each, we modify a previous excitability model and include synaptic currents able to drive APs at frequencies as high as 600 Hz. Synaptic stimuli are modeled as pulsatile cation conductance changes, with or without a small (sustained) background conductance. Over the full species range of EOD frequencies (200–600 Hz) we calculate frequency-dependent “Na+-entry budgets” for an electrocyte AP as a surrogate for required 3Na+/2K+-ATPase activity. We find that the cost per AP of maintaining constant-amplitude APs increases nonlinearly with frequency, whereas the cost per AP for synaptic input current is essentially constant. This predicts that Na+ channel density should correlate positively with EOD frequency, whereas AChR density should be the same across fish. Importantly, calculated costs (inferred from Na+-entry through Nav and ACh channels) for electrocyte APs as frequencies rise are much less than expected from published whole-fish EOD-linked O2 consumption. For APs at increasingly high frequencies, we suggest that EOD-related costs external to electrocytes (including packaging of synaptic transmitter) substantially exceed the direct cost of electrocyte ion homeostasis. PMID:29708986
NASA Astrophysics Data System (ADS)
Šilhán, Karel
2014-02-01
High-gradient channels are the locations of the greatest geomorphological activity in medium-high mountains. The channels' frequency and character influence the contemporary morphology and morphometry of alluvial fans. There is currently no detailed information regarding the frequency of these processes in high-gradient channels and the evolution of alluvial fans in medium-high mountains in Central Europe. This study in the Moravskoslezské Beskydy Mts. analysed 22 alluvial fans (10 debris flow fans and 12 fluvial fans). The processes occurring on the fans were dated using dendrogeomorphological methods. A total of 748 increment cores were taken from 374 trees to reconstruct 153 geomorphological process events (60 debris flow and 93 floods). The frequency of the processes has been considerably increasing in the last four decades, which can be related to extensive tree cutting since the 1970s. Processes in high-gradient channels in the region (affecting the alluvial fans across the mountain range) are predominantly controlled by cyclonal activity during the warm periods of the year. Probable triggers of local events are heavy downpours in the summer. In addition, spring snowmelt has been identified as occasionally important. This study of the relations affecting the type and frequency of the processes and their effect on the properties of alluvial fans led to the creation of a universal framework for the medium-high flysch mountains of Central Europe. The framework particularly reflects the influence of the character of hydrometeorological extremes on the frequency and type of processes and their reflection in the properties of alluvial fans.
NASA Astrophysics Data System (ADS)
Kagawa, T.; Tsurugi, M.; Irikura, K.
2006-12-01
A study on high frequency cut-off characteristics of strong ground motion is presented for subduction and intra- slab earthquakes in Japan. In the latest decade, observed records at hard sites are published by NIED, National Research Institute for Earth Science and Disaster Prevention, and JCOLD, Japan Commission on Large Dams. Especially, KiK-net and K-NET maintained by NIED have been providing high quality data to study high-frequency characteristics. Kagawa et al.(2003) studied the characteristics for crustal earthquakes. We apply the same methodology to the recently observed Japanese records due to subduction and intra-slab earthquakes. We assume a Butterworth type high-cut filter with limit frequency (fmax) and its power factor. These two parameters were derived from Fourier spectrum of observed records fitting the theoretical filter shape. After analyzing the result from view points of site, path, or source effects, an averaged filter model is proposed with its standard deviation. Kagawa et al.(2003) derived average as 8.3 Hz with power factor of 1.92. It is used for strong ground motion simulation. We will propose parameters for the high-cut filters of subduction and intra-slab earthquakes and compare them with the results by Kagawa et al.(2003). REFERENCES: Kagawa et al. (2003), 27JEES (in Japanese with English Abstract).
NASA Astrophysics Data System (ADS)
Ezer, Tal; Atkinson, Larry P.
2017-06-01
Recent studies show that in addition to wind and air pressure effects, a significant portion of the variability of coastal sea level (CSL) along the US East Coast can be attributed to non-local factors such as variations in the Gulf Stream and the North Atlantic circulation; these variations can cause unpredictable coastal flooding. The Florida Current transport (FCT) measurement across the Florida Straits monitors those variations, and thus, the study evaluated the potential of using the FCT as an indicator for anomalously high water level along the coast. Hourly water level data from 12 tide gauge stations over 12 years are used to construct records of maximum daily water levels (MDWL) that are compared with the daily FCT data. An empirical mode decomposition (EMD) approach is used to divide the data into high-frequency modes (periods T < ˜30 days), middle-frequency modes (˜30 days < T < ˜90 days), and low-frequency modes (˜90 days < T < ˜1 year). Two predictive measures are tested: FCT and FCT change (FCC). FCT is anti-correlated with MDWL in high-frequency modes but positively correlated with MDWL in low-frequency modes. FCC on the other hand is always anti-correlated with MDWL for all frequency bands, and the high water signal lags behind FCC for almost all stations, thus providing a potential predictive skill (i.e., whenever a weakening trend is detected in the FCT, anomalously high water is expected along the coast over the next few days). The MDWL-FCT correlation in the high-frequency modes is maximum in the lower Mid-Atlantic Bight, suggesting influence from the meandering Gulf Stream after it separates from the coast. However, the correlation in low-frequency modes is maximum in the South Atlantic Bight, suggesting impact from variations in the wind pattern over subtropical regions. The middle-frequency and low-frequency modes of the FCT seem to provide the best predictor for medium to large flooding events; it is estimated that ˜10-25% of the sea level variability in those modes can be attributed to variations in the FCT. An example from Hurricane Joaquin (September-October, 2015) demonstrates how an offshore storm that never made landfall can cause a weakening of the FCT and unexpected high water level and flooding along the US East Coast. A regression-prediction model based on the MDWL-FCT correlation shows some skill in estimating high water levels during past storms; the water level prediction is more accurate for slow-moving and offshore storms than it is for fast-moving storms. The study can help to improve water level prediction since current storm surge models rely on local wind but may ignore remote forcing.
Picconi, Maria Alejandra; Gronda, Jorge; Alonio, Lidia V; Villa, Luisa L; Sichero, Laura; Miranda, Sergio; Barcena, Martin; Teyssie, Angelica
2002-01-01
Human Papillomaviruses (HPVs) are etiologically associated to cervical carcinoma. In order to evaluate HPV infection and its relationship with the high frequency of this neoplasia in Quechua women from Jujuy (Argentina), 271 cervical samples from preneoplastic and neoplastic lesions (biopsies) and normal controls (cytologies) were studied. Detection and typing were performed using PCR-RFLP or PCR-hybridization and the HPV-16 variability in L1 and E6 genes (by PCR-hybridization) was analysed. HPV was detected in 52% of controls, 91% of low-grade lesions, 97% of high-grade lesions and 100% of invasive carcinomas, corresponding 55% to HPV-16. HPV-16 European variants were predominant, most of them being non-prototypic strains. The high frequency of high risk infection types and the raised proportion of HPV-16 non-prototypic variants related to a greater oncogenic potential could explain, in part, the high cervical cancer frequency of this native population. These data may contribute to disease control and vaccinal formulation.
Factors associated with poor sleep during menopause: results from the Midlife Women's Health Study.
Smith, Rebecca L; Flaws, Jodi A; Mahoney, Megan M
2018-05-01
Poor sleep is one of the most common problems reported during menopause, and is known to vary throughout the menopause transition. The objective of this study was to describe the dynamics of poor sleep among participants of the Midlife Women's Health Study and to identify risk factors associated with poor sleep during the menopausal transition. Annual responses to surveys that included questions about the frequency of sleep disturbances and insomnia were analyzed to determine the likelihood of persistent poor sleep throughout the menopausal transition and the correlation of responses to the different sleep-related questions, including frequency of restless sleep during the first year of the study. Responses to questions about a large number of potential risk factors were used to identify risk factors for poor sleep. Poor sleep in premenopause was not predictive of poor sleep in perimenopause, and poor sleep in perimenopause was not predictive of poor sleep in postmenopause. Frequencies of each of the measures of poor sleep were highly correlated. For all sleep outcomes, high frequency of depression was related to a high frequency of poor sleep. Vasomotor symptoms were also significantly related with a higher frequency of all poor sleep outcomes. A history of smoking was also associated with higher frequencies of insomnia and sleep disturbances. The risk factors identified for poor sleep, depression and vasomotor symptoms, were consistently associated with poor sleep throughout the menopausal transition. The likelihood of these risk factors changed from premenopause, through perimenopause, and into postmenopause, however, which could explain changes in sleep difficulties across the menopausal transition. Treatment of these risk factors should be considered when addressing sleep difficulties in menopausal women. Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Yao, Wai Na; Turner, Christopher W.; Gantz, Bruce J.
2006-01-01
The purpose of this study was to investigate the stability over time of low-frequency auditory thresholds to better determine if the new technique of using a short-electrode cochlear implant that preserves residual low-frequency acoustic hearing can be a long-term solution for those with severe-to-profound hearing loss at high frequencies. The…
[Voluntary alpha-power increasing training impact on the heart rate variability].
Bazanova, O M; Balioz, N V; Muravleva, K B; Skoraia, M V
2013-01-01
In order to study the effect of the alpha EEG power increasing training at heart rate variability (HRV) as the index of the autonomic regulation of cognitive functions there were follow tasks: (1) to figure out the impact of biofeedback in the voluntary increasing the power in the individual high-frequency alpha-band effect on heart rate variability and related characteristics of cognitive and emotional spheres, (2) to determine the nature of the relationship between alpha activity indices and heart rate variability, depending on the alpha-frequency EEG pattern at rest (3) to examine how the individual alpha frequency EEG pattern is reflected in changes HRV as a result of biofeedback training. Psychometric indicators of cognitive performance, the characteristics of the alpha-EEG activity and heart rate variability (HRV) as LF/HF and pNN50 were recorded in 27 healthy men aged 18-34 years, before, during, and after 10 sessions of training of voluntary increase in alpha power in the individual high-frequency alpha band with eyes closed. To determine the biofeedback effect on the alpha power increasing training, data subjects are compared in 2 groups: experimental (14) with the real and the control group (13 people)--with mock biofeedback. The follow up effect of trainings was studied through month over the 10 training sessions. Results showed that alpha biofeedback training enhanced the fluency and accuracy in cognitive performance, decreased anxiety and frontal EMG, increased resting frequency, width and power in individual upper alpha range only in participants with low baseline alpha frequency. While mock biofeedback increased resting alpha power only in participants with high baseline resting alpha frequency and did change neither cognitive performance, nor HRV indices. Biofeedback training eliminated the alpha power decrease in response to arithmetic task in both with high and low alpha frequency participants and this effect was followed up over the month. Mock biofeedback training has no such effect. The positive correlation between the alpha-peak frequency and pNN50 in patients with initially low, but negative--those with high baseline alpha frequency explains the multidirectional biofeedback effects on HRV in low and high alpha frequency subjects. The individual alpha-frequency EEG pattern determines the effectiveness of the alpha EEG biofeedback training in changing heart rate variability, which provides a basis for predicting the results and develop individual approaches to the biofeedback technology implementation that can be used in clinical practice for treatment and rehabilitation of psychosomatic syndromes and in educational training.
Collocations of High Frequency Noun Keywords in Prescribed Science Textbooks
ERIC Educational Resources Information Center
Menon, Sujatha; Mukundan, Jayakaran
2012-01-01
This paper analyses the discourse of science through the study of collocational patterns of high frequency noun keywords in science textbooks used by upper secondary students in Malaysia. Research has shown that one of the areas of difficulty in science discourse concerns lexis, especially that of collocations. This paper describes a corpus-based…
Imaging a soil fragipans using a high-frequency MASW method
USDA-ARS?s Scientific Manuscript database
The objective of this study was to noninvasively image a fragipan layer, a naturally occurring dense soil layer, using a high-frequency (HF) multi-channel analysis of surface wave (MASW) method. The HF-MASW is developed to measure the soil profile in terms of the shear (S) wave velocity at depths up...
A Phase-Only technique for enhancing the high-frequency MASW method
USDA-ARS?s Scientific Manuscript database
For soil exploration in the vadose zone, a high-frequency multi-channel analysis of surface waves (HF-MASW) method has been developed. In the study, several practical techniques were applied to enhance the overtone image of the HF-MASW method. They included (1) the self-adaptive MASW method using a ...
NASA Astrophysics Data System (ADS)
Na, Byungkeun; Bae, Inshik; Park, Gi Jung; Chang, Hong-Young
2016-09-01
Multi-frequency capacitively coupled plasma (CCP) has been studied to independently control the ion energy and the ion flux; pulsing technique is used to reduce the electron temperature and finally the charging effects. The use of these techniques is a key to high aspect ratio contact (HARC) etching in the recent semiconductor processing. In this study, the characteristics of pulsed dual frequency (DF) CCP is investigated. Two separate powers of 3 MHz and 40 MHz are delivered to the powered electrode of an asymmetric CCP, and each frequency is modulated by an external 1 kHz pulse. Due to the complexity of the RF compensation in DF CCP, the characteristics of the plasma and the sheath are analyzed by high speed impedance measurement. The transient behavior of pulse modulated DF CCP is analyzed based on the result of continuous wave (CW) DF CCP. The optimized experimental condition for high ion energy will be presented. The difference between electronegative oxygen plasma and electropositive argon plasma is discussed as well.
Llopis-González, Agustín; Sánchez, Adriana L.; Requena, Pedro Martí; Suárez-Varela, María Morales
2014-01-01
Urban groundwater development was traditionally constrained by concerns about its quality. This study was conducted in the regions of La Ribera Alta and Ribera Baja and La Plana de Requena-Utiel of the Valencian Community (Valencia, Spain) where population density, demand for drinking water and agricultural activities are high. Groundwater bodies (GWBs) are regarded as management areas within each territory, and were used to establish protection policies. This study analyzed eleven GWBs. We used two databases with microbiological measurements from 154 wells over a 7-year period (2004–2011), risk factors and groundwater information. Wells were grouped according to frequency of microbiological contamination using E. coli measurements, category <1, or wells with low-frequency microbiological contamination and high-frequency wells or category 1–100, according to World Health Organization (WHO) quality criteria of drinking water. Of all wells, 18.12% showed high-frequency microbiological contamination with a majority distribution in the Ribera Alta region (26.98%, p < 0.001). No significant differences were found between the two risk categories for flow, static level, well depth and distance from population centres. This paper reveals that the vulnerability classes established by the Geological and Mining Institute of Spain (IGME) do not match the microbiological results, and that only eight wells with high-frequency contamination coincide with the high vulnerability areas. PMID:24859678
Exploring the limits of frequency lowering
Souza, Pamela E.; Arehart, Kathryn H.; Kates, James M.; Croghan, Naomi B.H.; Gehani, Namita
2013-01-01
Objective This study examined how frequency lowering affected sentence intelligibility and quality, for adults with postlingually acquired, mild-to-moderate hearing loss. Method Listeners included adults aged 60–92 years with sloping sensorineural loss and a control group of similarly-aged adults with normal hearing. Sentences were presented in quiet and babble at a range of signal-to-noise ratios. Intelligibility and quality were measured with varying amounts of frequency lowering, implemented using a form of frequency compression. Results Moderate amounts of compression, particularly with high cutoff frequencies, had minimal effects on intelligibility. Listeners with the greatest high-frequency hearing loss showed the greatest benefit. Sentence intelligibility decreased with more compression. Listeners were more affected by a given set of parameters in noise. In quiet, any amount of compression resulted in lower speech quality for most listeners, with the greatest degradation for listeners with better high-frequency hearing. Quality ratings were lower with background noise, and in noise the effect of changing compression parameters was small. Conclusions The benefits of frequency lowering in adults were affected by the compression parameters as well as individual hearing thresholds. Data are consistent with the idea that frequency lowering can be viewed in terms of an improved audibility vs increased distortion tradeoff. PMID:23785188
Exposure to electromagnetic fields aboard high-speed electric multiple unit trains.
Niu, D; Zhu, F; Qiu, R; Niu, Q
2016-01-01
High-speed electric multiple unit (EMU) trains generate high-frequency electric fields, low-frequency magnetic fields, and high-frequency wideband electromagnetic emissions when running. Potential human health concerns arise because the electromagnetic disturbances are transmitted mainly into the car body from windows, and from there to passengers and train staff. The transmission amount and amplitude distribution characteristics that dominate electromagnetic field emission need to be studied, and the exposure level of electromagnetic field emission to humans should be measured. We conducted a series of tests of the on board electromagnetic field distribution on several high-speed railway lines. While results showed that exposure was within permitted levels, the possibility of long-term health effects should be investigated.
Shcherbakov, Alexandre S; Arellanes, Adan Omar
2017-04-20
We present a principally new acousto-optical cell providing an advanced wideband spectrum analysis of ultra-high frequency radio-wave signals. For the first time, we apply a recently developed approach with the tilt angle to a one-phonon non-collinear anomalous light scattering. In contrast to earlier cases, now one can exploit a regime with the fixed optical wavelength for processing a great number of acoustic frequencies simultaneously in the linear regime. The chosen rutile-crystal combines a moderate acoustic velocity with low acoustic attenuation and allows us wide-band data processing within GHz-frequency acoustic waves. We have created and experimentally tested a 6-cm aperture rutile-made acousto-optical cell providing the central frequency 2.0 GHz, frequency bandwidth ∼0.52 GHz with the frequency resolution about 68.3 kHz, and ∼7620 resolvable spots. A similar cell permits designing an advanced ultra-high-frequency arm within a recently developed multi-band radio-wave acousto-optical spectrometer for astrophysical studies. This spectrometer is intended to operate with a few parallel optical arms for processing the multi-frequency data flows within astrophysical observations. Keeping all the instrument's advantages of the previous schematic arrangement, now one can create the highest-frequency arm using the developed rutile-based acousto-optical cell. It permits optimizing the performances inherent in that arm via regulation of both the central frequency and the frequency bandwidth for spectrum analysis.
Seafloor Pressure Array Studies at Ultra-Low Frequencies
1991-01-01
broadband instrument design and deployment. In order to measure broadband noise routinely, a low frequency pressure gauge designed for deep ocean...below the microseism band (Moore et al, 1981). A differential pressure gauge , developed for low frequency recordings by Cox et al (1984) and sensitive to...design differential pressure gauge (Cox et al, 1984) with a sensitivity -3- ULF Seafloor Pressure Array Studies range of 0.01-5 Hz. The high
Satellite time and frequency transfer (STIFT)
NASA Technical Reports Server (NTRS)
Vessot, R. F. C.
1983-01-01
The concept of placing a hydrogen maser high stability clock in Earth orbit to provide accurate time and frequency comparisons worldwide to major timing centers and to a large number of radio observatory antenna sites involved in VLBI measurements was studied. The proposal was chiefly directed toward studies and initial hardware designs for time comparisons between hydrogen maser frequency standards and to modifications of the hydrogen maser for long-term use in space.
Megawatt Space Power Conditioning, Distribution, and Control Study
1988-03-01
also must be given to the design of an ac transmission line for this relatively high frequency . 2.3.2 Medium High Voltage Systems. Figure 2-4 shows a...systems are designed to exploit the use of 2 MW klystrode tubes (see Section 3.1) which require a dc voltage of about 140 kV. This high voltage can be...the concerns is that to date there have been no three-phase high voltage, high frequency transmission lines designed . Figure 5-6. While the previous
Atmospheric and Fog Effects on Ultra-Wide Band Radar Operating at Extremely High Frequencies.
Balal, Nezah; Pinhasi, Gad A; Pinhasi, Yosef
2016-05-23
The wide band at extremely high frequencies (EHF) above 30 GHz is applicable for high resolution directive radars, resolving the lack of free frequency bands within the lower part of the electromagnetic spectrum. Utilization of ultra-wideband signals in this EHF band is of interest, since it covers a relatively large spectrum, which is free of users, resulting in better resolution in both the longitudinal and transverse dimensions. Noting that frequencies in the millimeter band are subjected to high atmospheric attenuation and dispersion effects, a study of the degradation in the accuracy and resolution is presented. The fact that solid-state millimeter and sub-millimeter radiation sources are producing low power, the method of continuous-wave wideband frequency modulation becomes the natural technique for remote sensing and detection. Millimeter wave radars are used as complementary sensors for the detection of small radar cross-section objects under bad weather conditions, when small objects cannot be seen by optical cameras and infrared detectors. Theoretical analysis for the propagation of a wide "chirped" Frequency-Modulated Continuous-Wave (FMCW) radar signal in a dielectric medium is presented. It is shown that the frequency-dependent (complex) refractivity of the atmospheric medium causes distortions in the phase of the reflected signal, introducing noticeable errors in the longitudinal distance estimations, and at some frequencies may also degrade the resolution.
Cordes, Dietmar; Nandy, Rajesh R.; Schafer, Scott; Wager, Tor D.
2014-01-01
It has recently been shown that both high-frequency and low-frequency cardiac and respiratory noise sources exist throughout the entire brain and can cause significant signal changes in fMRI data. It is also known that the brainstem, basal forebrain and spinal cord area are problematic for fMRI because of the magnitude of cardiac-induced pulsations at these locations. In this study, the physiological noise contributions in the lower brain areas (covering the brainstem and adjacent regions) are investigated and a novel method is presented for computing both low-frequency and high-frequency physiological regressors accurately for each subject. In particular, using a novel optimization algorithm that penalizes curvature (i.e. the second derivative) of the physiological hemodynamic response functions, the cardiac -and respiratory-related response functions are computed. The physiological noise variance is determined for each voxel and the frequency-aliasing property of the high-frequency cardiac waveform as a function of the repetition time (TR) is investigated. It is shown that for the brainstem and other brain areas associated with large pulsations of the cardiac rate, the temporal SNR associated with the low-frequency range of the BOLD response has maxima at subject-specific TRs. At these values, the high-frequency aliased cardiac rate can be eliminated by digital filtering without affecting the BOLD-related signal. PMID:24355483
Atmospheric and Fog Effects on Ultra-Wide Band Radar Operating at Extremely High Frequencies
Balal, Nezah; Pinhasi, Gad A.; Pinhasi, Yosef
2016-01-01
The wide band at extremely high frequencies (EHF) above 30 GHz is applicable for high resolution directive radars, resolving the lack of free frequency bands within the lower part of the electromagnetic spectrum. Utilization of ultra-wideband signals in this EHF band is of interest, since it covers a relatively large spectrum, which is free of users, resulting in better resolution in both the longitudinal and transverse dimensions. Noting that frequencies in the millimeter band are subjected to high atmospheric attenuation and dispersion effects, a study of the degradation in the accuracy and resolution is presented. The fact that solid-state millimeter and sub-millimeter radiation sources are producing low power, the method of continuous-wave wideband frequency modulation becomes the natural technique for remote sensing and detection. Millimeter wave radars are used as complementary sensors for the detection of small radar cross-section objects under bad weather conditions, when small objects cannot be seen by optical cameras and infrared detectors. Theoretical analysis for the propagation of a wide “chirped” Frequency-Modulated Continuous-Wave (FMCW) radar signal in a dielectric medium is presented. It is shown that the frequency-dependent (complex) refractivity of the atmospheric medium causes distortions in the phase of the reflected signal, introducing noticeable errors in the longitudinal distance estimations, and at some frequencies may also degrade the resolution. PMID:27223286
Radio-frequency measurement in semiconductor quantum computation
NASA Astrophysics Data System (ADS)
Han, TianYi; Chen, MingBo; Cao, Gang; Li, HaiOu; Xiao, Ming; Guo, GuoPing
2017-05-01
Semiconductor quantum dots have attracted wide interest for the potential realization of quantum computation. To realize efficient quantum computation, fast manipulation and the corresponding readout are necessary. In the past few decades, considerable progress of quantum manipulation has been achieved experimentally. To meet the requirements of high-speed readout, radio-frequency (RF) measurement has been developed in recent years, such as RF-QPC (radio-frequency quantum point contact) and RF-DGS (radio-frequency dispersive gate sensor). Here we specifically demonstrate the principle of the radio-frequency reflectometry, then review the development and applications of RF measurement, which provides a feasible way to achieve high-bandwidth readout in quantum coherent control and also enriches the methods to study these artificial mesoscopic quantum systems. Finally, we prospect the future usage of radio-frequency reflectometry in scaling-up of the quantum computing models.
Effect of HeartMate left ventricular assist device on cardiac autonomic nervous activity.
Kim, S Y; Montoya, A; Zbilut, J P; Mawulawde, K; Sullivan, H J; Lonchyna, V A; Terrell, M R; Pifarré, R
1996-02-01
Clinical performance of a left ventricular assist device is assessed via hemodynamic parameters and end-organ function. This study examined effect of a left ventricular assist device on human neurophysiology. This study evaluated the time course change of cardiac autonomic activity of 3 patients during support with a left ventricular assist device before cardiac transplantation. Cardiac autonomic activity was determined by power spectral analysis of short-term heart rate variability. The heart rate variability before cardiac transplantation was compared with that on the day before left ventricular assist device implantation. The standard deviation of the mean of the R-R intervals of the electrocardiogram, an index of vagal activity, increased to 27 +/- 7 ms from 8 +/- 0.6 ms. The modulus of power spectral components increased. Low frequency (sympathetic activity) and high frequency power (vagal activity) increased by a mean of 9 and 22 times of each baseline value (low frequency power, 5.2 +/- 3.0 ms2; high frequency power, 2.1 +/- 0.7 ms2). The low over high frequency power ratio decreased substantially, indicating an improvement of cardiac sympatho-vagal balance. The study results suggest that left ventricular assist device support before cardiac transplantation may exert a favorable effect on cardiac autonomic control in patients with severe heart failure.
Wang, Le; Devore, Sasha; Delgutte, Bertrand
2013-01-01
Human listeners are sensitive to interaural time differences (ITDs) in the envelopes of sounds, which can serve as a cue for sound localization. Many high-frequency neurons in the mammalian inferior colliculus (IC) are sensitive to envelope-ITDs of sinusoidally amplitude-modulated (SAM) sounds. Typically, envelope-ITD-sensitive IC neurons exhibit either peak-type sensitivity, discharging maximally at the same delay across frequencies, or trough-type sensitivity, discharging minimally at the same delay across frequencies, consistent with responses observed at the primary site of binaural interaction in the medial and lateral superior olives (MSO and LSO), respectively. However, some high-frequency IC neurons exhibit dual types of envelope-ITD sensitivity in their responses to SAM tones, that is, they exhibit peak-type sensitivity at some modulation frequencies and trough-type sensitivity at other frequencies. Here we show that high-frequency IC neurons in the unanesthetized rabbit can also exhibit dual types of envelope-ITD sensitivity in their responses to SAM noise. Such complex responses to SAM stimuli could be achieved by convergent inputs from MSO and LSO onto single IC neurons. We test this hypothesis by implementing a physiologically explicit, computational model of the binaural pathway. Specifically, we examined envelope-ITD sensitivity of a simple model IC neuron that receives convergent inputs from MSO and LSO model neurons. We show that dual envelope-ITD sensitivity emerges in the IC when convergent MSO and LSO inputs are differentially tuned for modulation frequency. PMID:24155013
D'Ippolito, Mariagrazia; Tramontano, Marco; Buzzi, Maria Gabriella
2017-06-01
The substantial functional impairment associated with migraine has both physical and emotional ramifications. Mood disorders are often comorbid in patients with migraine and are known to adversely affect migraine activity. To explore the effects of osteopathic manipulative therapy (OMTh; manipulative care provided by foreign-trained osteopaths) on pain and mood disorders in patients with high-frequency migraine. Retrospective review of the medical records of patients with high-frequency migraine who were treated with OMTh at the Headache Istituto di Ricovero e Cura a Carattere Scientifico Fondazione Santa Lucia from 2011 to 2015. Clinical assessments were made using the Headache Disability Inventory (HDI), the Headache Impact Test (HIT-6), the Hamilton Depression Rating Scale (HDRS), and the State-Trait Anxiety Inventory (STAI) forms X-1 and X-2. Medical records of 11 patients (6 women; mean age, 47.5 [7.8] years) with a diagnosis of high-frequency migraine who participated in an OMTh program met the inclusion criteria and were included in the study. When the questionnaire scores obtained at the first visit (T0) and after 4 OMTh sessions (T1) were compared, significant improvement in scores were observed on STAI X-2 (T0: 43.18 [2.47]; T1: 39.45 [2.52]; P<.05), HIT-6 (T0: 63 [2.20]; T1: 56.27 [2.24]; P<.05), and HDI (T0: 58.72 [6.75]; T1: 45.09 [7.01]; P<.05). This preliminary study revealed that patients with high-frequency migraine and comorbid mood disorders showed significant improvement after four 45-minute OMTh sessions. Further investigation into the effects of OMTh on pain and mood disorders in patients with high-frequency migraine is needed.
Gutiérrez-Rojas, Luis; Jurado, Dolores; Martínez-Ortega, José María; Gurpegui, Manuel
2010-12-01
We analyzed the association of previous course-of-illness and other variables of clinical interest with a high frequency of both depressive or (hypo)manic episodes controlling for the effect of socio-demographic characteristics. A total of 108 outpatients with a DSM-IV diagnosis of bipolar disorder (BD) were recruited. A retrospective and naturalistic study was conducted to examine the number of affective episodes and their relationship with socio-demographic, clinical and course-of-illness variables, including adherence to medication, type of medication used and the use of addictive substances. The episode frequency was estimated as the number of "major instances" of depression, hypomania and mania during the illness. To classify the patients into two groups (higher and lower-episode frequency), we used the statistical criterion of median split. Results were analyzed with logistic regression models to control for the effects of potential confounders. A high episode frequency (nine or more episodes) was associated with age (36-55years), delay in diagnosis, poor adherence to medication and current use of antipsychotic medication. In addition, a high frequency of manic episodes (four or more) was associated with female sex, age (>36years) and a manic onset of the illness, whereas a high frequency of depressive episodes (five or more) was associated with delay in diagnosis and poor adherence to medication. Cross-sectional study design. Avoiding delay in diagnosis and enhancing treatment adherence might be important targets for reducing recurrences in BD. Copyright © 2010 Elsevier B.V. All rights reserved.
Sound level-dependent growth of N1m amplitude with low and high-frequency tones.
Soeta, Yoshiharu; Nakagawa, Seiji
2009-04-22
The aim of this study was to determine whether the amplitude and/or latency of the N1m deflection of auditory-evoked magnetic fields are influenced by the level and frequency of sound. The results indicated that the amplitude of the N1m increased with sound level. The growth in amplitude with increasing sound level was almost constant with low frequencies (250-1000 Hz); however, this growth decreased with high frequencies (>2000 Hz). The behavior of the amplitude may reflect a difference in the increase in the activation of the peripheral and/or central auditory systems.
A perspective on high-frequency ultrasound for medical applications
NASA Astrophysics Data System (ADS)
Mamou, Jonathan; Aristizába, Orlando; Silverman, Ronald H.; Ketterling, Jeffrey A.
2010-01-01
High-frequency ultrasound (HFU, >15 MHz) is a rapidly developing field. HFU is currently used and investigated for ophthalmologic, dermatologic, intravascular, and small-animal imaging. HFU offers a non-invasive means to investigate tissue at the microscopic level with resolutions often better than 100 μm. However, fine resolution is only obtained over the limited depth-of-field (˜1 mm) of single-element spherically-focused transducers typically used for HFU applications. Another limitation is penetration depth because most biological tissues have large attenuation at high frequencies. In this study, two 5-element annular arrays with center frequencies of 17 and 34 MHz were fabricated and methods were developed to obtain images with increased penetration depth and depth-of-field. These methods were used in ophthalmologic and small-animal imaging studies. Improved blood sensitivity was obtained when a phantom mimicking a vitreous hemorrhage was imaged. Central-nervous systems of 12.5-day-old mouse embryos were imaged in utero and in three dimensions for the first time.
Dynamics of Quasi-Electrostatic Whistler waves in Earth's Radiation belts
NASA Astrophysics Data System (ADS)
Goyal, R.; Sharma, R. P.; Gupta, D. N.
2017-12-01
A numerical model is proposed to study the dynamics of high amplitude quasi-electrostatic whistler waves propagating near resonance cone angle and their interaction with finite frequency kinetic Alfvén waves (KAWs) in Earth's radiation belts. The quasi-electrostatic character of whistlers is narrated by dynamics of wave propagating near resonance cone. A high amplitude whistler wave packet is obtained using the present analysis which has also been observed by S/WAVES instrument onboard STEREO. The numerical simulation technique employed to study the dynamics, leads to localization (channelling) of waves as well as turbulent spectrum suggesting the transfer of wave energy over a range of frequencies. The turbulent spectrum also indicates the presence of quasi-electrostatic whistlers and density fluctuations associated with KAW in radiation belts plasma. The ponderomotive force of pump quasi-electrostatic whistlers (high frequency) is used to excite relatively much lower frequency waves (KAWs). The wave localization and steeper spectra could be responsible for particle energization or heating in radiation belts.
NASA Astrophysics Data System (ADS)
Lee, Scott A.
2014-03-01
High-pressure Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the low-frequency vibrational modes of crystalline cytidine at 295 K by evaluating the logarithmic derivative of the vibrational frequency with respect to pressure: 1/ω dω/dP. Crystalline samples of molecular materials such as cytidine have vibrational modes that are localized within a molecular unit (``internal'' modes) as well as modes in which the molecular units vibrate against each other (``external'' modes). The value of the logarithmic derivative is a diagnostic probe of the nature of the eigenvector of the vibrational modes, making high pressure experiments a very useful probe for such studies. Internal stretching modes have low logarithmic derivatives while external as well as internal torsional and bending modes have higher logarithmic derivatives. All of the Raman modes below 200 cm-1 in cytidine are found to have high logarithmic derivatives, consistent with being either external modes or internal torsional or bending modes.
Contact Allergy to Hydroperoxides of Linalool and D-Limonene in a US Population.
Nath, Neel Som; Liu, Beiyu; Green, Cynthia; Atwater, Amber Reck
Linalool and D-limonene are common fragrance ingredients that readily oxidize on exposure to air. The resulting hydroperoxides of linalool and D-limonene have been shown to have high frequencies of positive patch test reactions in several European and international studies. The aim of the study was to investigate the prevalence of contact allergy to the hydroperoxides of linalool and D-limonene in a US population. In this retrospective study, 103 patients with suspected fragrance allergy were patch tested to linalool 10% petrolatum (pet), hydroperoxides of linalool 1% pet, D-limonene 10% pet, and/or the hydroperoxides of D-limonene 0.3% pet between July 9, 2014, and October 25, 2016. In this study, the frequency of positive patch test reactions to the hydroperoxides of linalool is 20% (19/96), and the frequency of positive reactions to the hydroperoxides of D-limonene is 8% (7/90). These high frequencies suggest that patch testing to the hydroperoxides of linalool and limonene should be performed in all patients with suspected fragrance allergy.
Study of the use of a nonlinear, rate limited, filter on pilot control signals
NASA Technical Reports Server (NTRS)
Adams, J. J.
1977-01-01
The use of a filter on the pilot's control output could improve the performance of the pilot-aircraft system. What is needed is a filter with a sharp high frequency cut-off, no resonance peak, and a minimum of lag at low frequencies. The present investigation studies the usefulness of a nonlinear, rate limited, filter in performing the needed function. The nonlinear filter is compared with a linear, first order filter, and no filter. An analytical study using pilot models and a simulation study using experienced test pilots was performed. The results showed that the nonlinear filter does promote quick, steady maneuvering. It is shown that the nonlinear filter attenuates the high frequency remnant and adds less phase lag to the low frequency signal than does the linear filter. It is also shown that the rate limit in the nonlinear filter can be set to be too restrictive, causing an unstable pilot-aircraft system response.
Pepler, Anna; Lewis, Kathryn; Munro, Kevin J
2016-01-01
Cochlear dead regions (DR) are common in adult hearing-aid users, but are usually restricted to high frequencies. The aim was to determine the benefit of high-frequency amplification for ears with and without high-frequency DRs. Participants were fitted with the study hearing aid and tested under four conditions: unfiltered (NAL-NL2 prescription), and low-pass filtered at 1.5, 2, and 3 kHz. VCV stimuli were presented at 65 dB (A) in quiet and in 20-talker babble at a signal-to-babble ratio of 0 dB. Experienced adult hearing-aid users: one group of 18 with a DR edge frequency above 1.5 kHz, and a group of 18 matched controls. Overall performance was best in the unfiltered condition. There was no significant difference in mean performance between the two groups when tested in quiet. However, the DR group obtained less benefit from high-frequency amplification when tested in babble: the mean difference between the unfiltered and 3-kHz filtered condition was 6% and 13% for the DR group and controls, respectively. In adults with a moderate hearing loss and a restricted DR, speech recognition was always best in the unfiltered condition, although mean performance in babble was lower for the DR group.
High Frequency Amplitude Detector for GMI Magnetic Sensors
Asfour, Aktham; Zidi, Manel; Yonnet, Jean-Paul
2014-01-01
A new concept of a high-frequency amplitude detector and demodulator for Giant-Magneto-Impedance (GMI) sensors is presented. This concept combines a half wave rectifier, with outstanding capabilities and high speed, and a feedback approach that ensures the amplitude detection with easily adjustable gain. The developed detector is capable of measuring high-frequency and very low amplitude signals without the use of diode-based active rectifiers or analog multipliers. The performances of this detector are addressed throughout the paper. The full circuitry of the design is given, together with a comprehensive theoretical study of the concept and experimental validation. The detector has been used for the amplitude measurement of both single frequency and pulsed signals and for the demodulation of amplitude-modulated signals. It has also been successfully integrated in a GMI sensor prototype. Magnetic field and electrical current measurements in open- and closed-loop of this sensor have also been conducted. PMID:25536003
Brain stem auditory potentials evoked by clicks in the presence of high-pass filtered noise in dogs.
Poncelet, L; Deltenre, P; Coppens, A; Michaux, C; Coussart, E
2006-04-01
This study evaluates the effects of a high-frequency hearing loss simulated by the high-pass-noise masking method, on the click-evoked brain stem-evoked potentials (BAEP) characteristics in dogs. BAEP were obtained in response to rarefaction and condensation click stimuli from 60 dB normal hearing level (NHL, corresponding to 89 dB sound pressure level) to wave V threshold, using steps of 5 dB in eleven 58 to 80-day-old Beagle puppies. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation potential (RCDP). The procedure was repeated while constant level, high-pass filtered (HPF) noise was superposed to the click. Cut-off frequencies of the successively used filters were 8, 4, 2 and 1 kHz. For each condition, wave V and RCDP thresholds, and slope of the wave V latency-intensity curve (LIC) were collected. The intensity range at which RCDP could not be recorded (pre-RCDP range) was calculated. Compared with the no noise condition, the pre-RCDP range significantly diminished and the wave V threshold significantly increased when the superposed HPF noise reached the 4 kHz area. Wave V LIC slope became significantly steeper with the 2 kHz HPF noise. In this non-invasive model of high-frequency hearing loss, impaired hearing of frequencies from 8 kHz and above escaped detection through click BAEP study in dogs. Frequencies above 13 kHz were however not specifically addressed in this study.
Dielectric and modulus studies of polycrystalline BaZrO3 ceramic
NASA Astrophysics Data System (ADS)
Saini, Deepash S.; Singh, Sunder; Kumar, Anil; Bhattacharya, D.
2018-05-01
In the present work, dielectric and modulus studies of polycrystalline BaZrO3 ceramic, prepared by modified combustion method followed by conventional sintering, are investigated over the frequency range of 100 Hz to 106 Hz at different temperatures from 250 to 500 °C in air. The high value of dielectric constant (ɛ' ˜ 103) of BaZrO3 at high temperature and low frequency can be attributed to the Maxwell-Wagner polarization mechanism as well as to the thermally activated mechanism of charge carriers. Electric modulus reveal two type relaxations in the 250 °C to 800 °C temperature region as studied at different frequencies over 100 Hz to 106 Hz in air.
Effect of Y2O3 on polyindole for high frequency capacitor application
NASA Astrophysics Data System (ADS)
Maji, P.; Choudhary, R. B.; Majhi, M.
2017-05-01
Polyindole-Yittrium Oxide (PIn-Y2O3) composite was synthesized in the laboratory through chemical polymerization process. The structural and morphological studies of PIn-Y2O3 composite were investigated using X-ray diffraction (XRD) and scanning electron microscopic (SEM) techniques. These studies showed that PIn-Y2O3 composite was amorphous in nature and formed with spherical granule shape. The dielectric response was measured through LCR meter in the frequency range from 100 Hz to 1 MHz. The dielectric studies revealed that incorporation of Y2O3 into polymeric matrix improved the dielectric behavior of PIn polymer and markedly suitable for its application in high frequency capacitor and many other electronic devices.
Effects of spatial frequency content on classification of face gender and expression.
Aguado, Luis; Serrano-Pedraza, Ignacio; Rodríguez, Sonia; Román, Francisco J
2010-11-01
The role of different spatial frequency bands on face gender and expression categorization was studied in three experiments. Accuracy and reaction time were measured for unfiltered, low-pass (cut-off frequency of 1 cycle/deg) and high-pass (cutoff frequency of 3 cycles/deg) filtered faces. Filtered and unfiltered faces were equated in root-mean-squared contrast. For low-pass filtered faces reaction times were higher than unfiltered and high-pass filtered faces in both categorization tasks. In the expression task, these results were obtained with expressive faces presented in isolation (Experiment 1) and also with neutral-expressive dynamic sequences where each expressive face was preceded by a briefly presented neutral version of the same face (Experiment 2). For high-pass filtered faces different effects were observed on gender and expression categorization. While both speed and accuracy of gender categorization were reduced comparing to unfiltered faces, the efficiency of expression classification remained similar. Finally, we found no differences between expressive and non expressive faces in the effects of spatial frequency filtering on gender categorization (Experiment 3). These results show a common role of information from the high spatial frequency band in the categorization of face gender and expression.
Asynchronous BCI control using high-frequency SSVEP.
Diez, Pablo F; Mut, Vicente A; Avila Perona, Enrique M; Laciar Leber, Eric
2011-07-14
Steady-State Visual Evoked Potential (SSVEP) is a visual cortical response evoked by repetitive stimuli with a light source flickering at frequencies above 4 Hz and could be classified into three ranges: low (up to 12 Hz), medium (12-30) and high frequency (> 30 Hz). SSVEP-based Brain-Computer Interfaces (BCI) are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range. However, they only evaluate the performance of different methods to extract SSVEP. This research proposed a high-frequency SSVEP-based asynchronous BCI in order to control the navigation of a mobile object on the screen through a scenario and to reach its final destination. This could help impaired people to navigate a robotic wheelchair. There were three different scenarios with different difficulty levels (easy, medium and difficult). The signal processing method is based on Fourier transform and three EEG measurement channels. The research obtained accuracies ranging in classification from 65% to 100% with Information Transfer Rate varying from 9.4 to 45 bits/min. Our proposed method allows all subjects participating in the study to control the mobile object and to reach a final target without prior training.
Holcomb, H H; Ritzl, E K; Medoff, D R; Nevitt, J; Gordon, B; Tamminga, C A
1995-06-29
Psychophysical and cognitive studies carried out in schizophrenic patients show high within-group performance variance and sizable differences between patients and normal volunteers. Experimental manipulation of a target's signal-to-noise characteristics can, however, make a given task more or less difficult for a given subject. Such signal-to-noise manipulations can substantially reduce performance differences between individuals. Frequency and presentation level (volume) changes of an auditory tone can make a sound more or less difficult to recognize. This study determined how the discrimination accuracy of medicated schizophrenic patients and normal volunteers changed when the frequency difference between two tones (high frequency vs. low frequency) and the presentation levels of tones were systematically degraded. The investigators hypothesized that each group would become impaired in its discrimination accuracy when tone signals were degraded by making the frequencies more similar and the presentation levels lower. Schizophrenic patients were slower and less accurate than normal volunteers on tests using four tone levels and two frequency differences; the schizophrenic patient group showed a significant decrement in accuracy when the signal-to-noise characteristics of the target tones were degraded. The benefits of controlling stimulus discrimination difficulty in functional imaging paradigms are discussed.
Hiew, Tze Ning; Huang, Rongying; Popov, Ivan; Feldman, Yuri; Heng, Paul Wan Sia
2017-12-01
This study explored the potential of combining the use of moisture sorption isotherms and dielectric relaxation profiles of starch and sodium starch glycolate (SSG) to probe the location of moisture in dried and hydrated samples. Starch and SSG samples, dried and hydrated, were prepared. For hydrated samples, their moisture contents were determined. The samples were probed by dielectric spectroscopy using a frequency band of 0.1 Hz to 1 MHz to investigate their moisture-related relaxation profiles. The moisture sorption and desorption isotherms of starch and SSG were generated using a vapor sorption analyzer, and modeled using the Guggenheim-Anderson-de Boer equation. A clear high frequency relaxation process was detected in both dried and hydrated starches, while for dried starch, an additional slower low frequency process was also detected. The high frequency relaxation processes in hydrated and dried starches were assigned to the coupled starch-hydrated water relaxation. The low frequency relaxation in dried starch was attributed to the local chain motions of the starch backbone. No relaxation process associated with water was detected in both hydrated and dried SSG within the frequency and temperature range used in this study. The moisture sorption isotherms of SSG suggest the presence of high energy free water, which could have masked the relaxation process of the bound water during dielectric measurements. The combined study of moisture sorption isotherms and dielectric spectroscopy was shown to be beneficial and complementary in probing the effects of moisture on the relaxation processes of starch and SSG.
Frequency Dependence of Single-Event Upset in Highly Advanced PowerPC Microprocessors
NASA Technical Reports Server (NTRS)
Irom, Farokh; Farmanesh, Farhad; White, Mark; Kouba, Coy K.
2006-01-01
Single-event upset effects from heavy ions were measured for Motorola silicon-on-insulator (SOI) microprocessor with 90 nm feature sizes at three frequencies of 500, 1066 and 1600 MHz. Frequency dependence of single-event upsets is discussed. The results of our studies suggest the single-event upset in registers and D-Cache tend to increase with frequency. This might have important implications for the overall single-event upset trend as technology moves toward higher frequencies.
Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong
2016-07-01
To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value < 0.05). The low-frequency transducer was more sensitive than the high-frequency transducer in breast CEUS using SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.
Dale, Gillian; Arnell, Karen M.
2014-01-01
Visual stimuli can be perceived at a broad, “global” level, or at a more focused, “local” level. While research has shown that many individuals demonstrate a preference for global information, there are large individual differences in the degree of global/local bias, such that some individuals show a large global bias, some show a large local bias, and others show no bias. The main purpose of the current study was to examine whether these dispositional differences in global/local bias could be altered through various manipulations of high/low spatial frequency. Through 5 experiments, we examined various measures of dispositional global/local bias and whether performance on these measures could be altered by manipulating previous exposure to high or low spatial frequency information (with high/low spatial frequency faces, gratings, and Navon letters). Ultimately, there was little evidence of change from pre-to-post manipulation on the dispositional measures, and dispositional global/local bias was highly reliable pre- to post-manipulation. The results provide evidence that individual differences in global/local bias or preference are relatively resistant to exposure to spatial frequency information, and suggest that the processing mechanisms underlying high/low spatial frequency use and global/local bias may be more independent than previously thought. PMID:24992321
Comparison of Frequency-Domain Array Methods for Studying Earthquake Rupture Process
NASA Astrophysics Data System (ADS)
Sheng, Y.; Yin, J.; Yao, H.
2014-12-01
Seismic array methods, in both time- and frequency- domains, have been widely used to study the rupture process and energy radiation of earthquakes. With better spatial resolution, the high-resolution frequency-domain methods, such as Multiple Signal Classification (MUSIC) (Schimdt, 1986; Meng et al., 2011) and the recently developed Compressive Sensing (CS) technique (Yao et al., 2011, 2013), are revealing new features of earthquake rupture processes. We have performed various tests on the methods of MUSIC, CS, minimum-variance distortionless response (MVDR) Beamforming and conventional Beamforming in order to better understand the advantages and features of these methods for studying earthquake rupture processes. We use the ricker wavelet to synthesize seismograms and use these frequency-domain techniques to relocate the synthetic sources we set, for instance, two sources separated in space but, their waveforms completely overlapping in the time domain. We also test the effects of the sliding window scheme on the recovery of a series of input sources, in particular, some artifacts that are caused by the sliding window scheme. Based on our tests, we find that CS, which is developed from the theory of sparsity inversion, has relatively high spatial resolution than the other frequency-domain methods and has better performance at lower frequencies. In high-frequency bands, MUSIC, as well as MVDR Beamforming, is more stable, especially in the multi-source situation. Meanwhile, CS tends to produce more artifacts when data have poor signal-to-noise ratio. Although these techniques can distinctly improve the spatial resolution, they still produce some artifacts along with the sliding of the time window. Furthermore, we propose a new method, which combines both the time-domain and frequency-domain techniques, to suppress these artifacts and obtain more reliable earthquake rupture images. Finally, we apply this new technique to study the 2013 Okhotsk deep mega earthquake in order to better capture the rupture characteristics (e.g., rupture area and velocity) of this earthquake.
2007-08-01
zooplankton scatterer types, perhaps dominated by copepods and gas- bearing siphonophores (Lawson et al., 2004). Similar analyses of multi-frequency...in this Gulf of Maine study region, gas-bearing siphonophores dominated scattering at all four BIOMAPER-II frequencies (Lavery et al., in press...with multi-frequency acoustics. 2. Away from these locations, other zooplankton dominated scattering, especially copepods and gas-bearing siphonophores
Study of Pulsations in the Atmosphere of the roAp star HD 137949
NASA Astrophysics Data System (ADS)
Sachkov, M.; Hareter, M.; Ryabchikova, T.; Wade, G.; Kochukhov, O.; Weiss, W. W.
The roAp star HD 137949 (33 Lib) shows the most complex pulsational behaviour among all roAp stars. Mkrtichian et al. (2003) found nearly anti-phase pulsations of Nd II and Nd III lines, which they attribute to the presence of a pulsation node high in the atmosphere of HD 137949. This was confirmed by Kurtz at al. (2005), who also find that in some REE lines the main frequency, corresponding to 8.27 min, and its harmonic have almost equal RV amplitudes. Based on high accuracy observations Ryabchikova et al. (2007a) studied pulsational characteristics of the HD 137949 atmosphere in detail. In general, spectroscopy provides 3D resolution of modes and allows to search for the photometrically undetectable frequencies. The high-accuracy space photometry provides very high-precision measurements of detected pulsation frequencies and enables an accurate phasing of multi-site spectroscopic data. A combination of simultaneous spectroscopy and photometry represents the most sophisticated asteroseismic dataset for any roAp star. In 2009 the star HD 137949 became a target of an intense observing campaign that combined ground-based spectroscopy with space photometry, obtained with the MOST satellite. We collected 780 spectra using the ESPaDOnS spectrograph mounted on the 3.6 m CFHT telescope; 374 spectra were obtained with the FIES spectrograph mounted on the 2.56-m NOT to perform the time-resolved spectroscopy of HD 137949. In addition, we used 111 UVES spectra (2004) from the ESO archive to check the mode stability. The frequency analysis of the new radial velocity (RV) measurements confirmed the previously reported frequency pattern (two frequencies and the first harmonic of the main frequency), and revealed an additional frequency at 1.991 mHz. The new frequency solution fits perfectly the RV variations from the 2004 and 2009 observational sets providing a strong support for the p-mode stability in the roAp star HD 137949 for at least 5 years.
Saint-Aubin, Jean; LeBlanc, Jacinthe
2005-12-01
In immediate serial recall, high-frequency words are better recalled than low-frequency words. Recently, it has been suggested that high-frequency words are better recalled because of their better long-term associative links, and not because of the intrinsic properties of their long-term representations. In the experiment reported here, recall performance was compared for pure lists of high- and low-frequency words, and for mixed lists composed of either one low- and five high-frequency words or the reverse. The usual advantage of high-frequency words was found with pure lists and this advantage was reduced, but still significant with mixed lists composed of five low-frequency words. However, the low-frequency word included in a high-frequency list was recalled just as well as high-frequency words. Results are challenging for the associative link hypothesis and are best interpreted within an item-based reconstruction hypothesis, along with a distinctiveness account.
High-frequency strontium vapor laser for biomedical applications
NASA Astrophysics Data System (ADS)
Hvorostovsky, A.; Kolmakov, E.; Kudashev, I.; Redka, D.; Kancer, A.; Kustikova, M.; Bykovskaya, E.; Mayurova, A.; Stupnikov, A.; Ruzankina, J.; Tsvetkov, K.; Lukyanov, N.; Paklinov, N.
2018-02-01
Sr-laser with high pulse repetition rate and high peak radiation power is a unique tool for studying rapidly occurring processes in time (plasma diagnostics, photoablation, etc.). In addition, the study of the frequency characteristics of the active medium of the laser helps to reveal the physics of the formation of an inverse medium in metal vapor lasers. In this paper, an experimental study of an Sr-laser with an active volume of 5.8 cm3 in the pulse repetition frequency range from 25 to 200 kHz is carried out, and a comparison with the frequency characteristics of media with large active volumes is given. We considered the frequency characteristics of the active medium in two modes: at a constant energy in the excitation pulse CU2 / 2 and at a constant average power consumed by the rectifier. In the presented work with a small-volume GRT using the TASITR-5/12 TASITRON switch, a laser was generated for Pairs of strontium at a CSF of 200 kHz. The behavior of the characteristics of the generation lines of 6.456 μm, 1 μm, and 3 μm at increased repetition frequencies is considered. Using the example of large-volume GRT, it is shown that tubes with a large active volume increase their energy characteristics with the growth of the CSF. The possibility of laser operation at pulse repetition rates above 200 kHz is shown.
NASA Astrophysics Data System (ADS)
Samanta, T.; Singh, J.; Sindhuja, G.; Banerjee, D.
2016-01-01
During the total solar eclipse of 11 July 2010, multi-slit spectroscopic observations of the solar corona were performed from Easter Island, Chile. To search for high-frequency waves, observations were taken at a high cadence in the green line at 5303 Å that is due to [Fe xiv] and the red line at 6374 Å that is due to [Fe x]. The data were analyzed to study the periodic variations in intensity, Doppler velocity, and line width using wavelet analysis. The data with high spectral and temporal resolution enabled us to study the rapid dynamical changes within coronal structures. We find that at certain locations, each parameter shows significant oscillation with periods ranging from 6 - 25 s. For the first time, we were able to detect damping of high-frequency oscillations with periods of about 10 s. If the observed damped oscillations are due to magnetohydrodynamic waves, then they can contribute significantly to the heating of the corona. From a statistical study we try to characterize the nature of the observed oscillations while considering the distribution of power in different line parameters.
Effect of Vibration Training on Anaerobic Power and Quardroceps Surface EMG in Long Jumpers
ERIC Educational Resources Information Center
Liu, Bin; Luo, Jiong
2015-01-01
Objective: To explore the anaerobic power and surface EMG (sEMG) of quardrocep muscle in lower extremities after single vibration training intervention. Methods: 8 excellent male long jumpers voluntarily participated in this study. Four intervention modes were devised, including high frequency high amplitude (HFHA,30Hz,6mm), low frequency low…
Picou, Erin M; Marcrum, Steven C; Ricketts, Todd A
2015-03-01
While potentially improving audibility for listeners with considerable high frequency hearing loss, the effects of implementing nonlinear frequency compression (NFC) for listeners with moderate high frequency hearing loss are unclear. The purpose of this study was to investigate the effects of activating NFC for listeners who are not traditionally considered candidates for this technology. Participants wore study hearing aids with NFC activated for a 3-4 week trial period. After the trial period, they were tested with NFC and with conventional processing on measures of consonant discrimination threshold in quiet, consonant recognition in quiet, sentence recognition in noise, and acceptableness of sound quality of speech and music. Seventeen adult listeners with symmetrical, mild to moderate sensorineural hearing loss participated. Better ear, high frequency pure-tone averages (4, 6, and 8 kHz) were 60 dB HL or better. Activating NFC resulted in lower (better) thresholds for discrimination of /s/, whose spectral center was 9 kHz. There were no other significant effects of NFC compared to conventional processing. These data suggest that the benefits, and detriments, of activating NFC may be limited for this population.
Oversampling in virtual visual sensors as a means to recover higher modes of vibration
NASA Astrophysics Data System (ADS)
Shariati, Ali; Schumacher, Thomas
2015-03-01
Vibration-based structural health monitoring (SHM) techniques require modal information from the monitored structure in order to estimate the location and severity of damage. Natural frequencies also provide useful information to calibrate finite element models. There are several types of physical sensors that can measure the response over a range of frequencies. For most of those sensors however, accessibility, limitation of measurement points, wiring, and high system cost represent major challenges. Recent optical sensing approaches offer advantages such as easy access to visible areas, distributed sensing capabilities, and comparatively inexpensive data recording while having no wiring issues. In this research we propose a novel methodology to measure natural frequencies of structures using digital video cameras based on virtual visual sensors (VVS). In our initial study where we worked with commercially available inexpensive digital video cameras we found that for multiple degrees of freedom systems it is difficult to detect all of the natural frequencies simultaneously due to low quantization resolution. In this study we show how oversampling enabled by the use of high-end high-frame-rate video cameras enable recovering all of the three natural frequencies from a three story lab-scale structure.
Moya, G; Dorado, P; Ferreiro, V; Naranjo, M E G; Peñas-Lledó, E M; LLerena, A
2017-07-01
A twofold higher frequency of CYP2D6 ultrarapid metabolizers (estimated from genotype: gUMs) was reported among Ashkenazi Jews (AJ) living in New York (USA) than in other North American Caucasians, which might be important to guide the prescription for CYP2D6 substrates in AJ communities around the world. This study was aimed to determine whether the high frequency of CYP2D6 gUMs described in AJ from USA was replicated in AJ from Argentina when compared with other multiethnic admixture Argentines (GA). The frequency of the most common allelic variants and of CYP2D6 gUMs (>2 active genes) and poor metabolizers (0 active genes, gPMs) was also compared among the studied Argentine populations. CYP2D6 genotyping was performed in 173 AJ and 246 GA DNA samples of unrelated donors from the metropolitan area of Buenos Aires. CYP2D6 alleles (*2, *3, *4, *5, *6, *10, *17, *35, *41 and multiple copies), genotypes and functional phenotype frequencies were determined. The frequencies of gUMs and gPMs in AJ from Argentina were 11.5% and 5.2%, respectively, whereas in GA, the frequencies of gUM and gPMs were 6.5% and 4.9%, respectively. Comparisons between AJ and GA showed that gUMs frequencies were twofold higher (P<0.05) in AJ than GA. CYP2D6*35 allele was more frequent in GA than AJ, whereas CYP2D6*41 and *1xN were more frequent in AJ than in GA (P<0.05). This study supports the previously reported high frequency of gUMs on another Ashkenazi population in New York. The present findings also support the interethnic variability of CYP2D6 genetic polymorphism in the overall Argentine population.
Miyazawa, Mitsuo; Torii, Takahiro; Toshimitsu, Yasuko; Okada, Katsuya; Ogawa, Nobuji; Shinozuka, Nozomi; Koyama, Isamu
2006-01-01
Compared to tumors located at the edge of the liver, tumors located directly on the liver surface are often difficult to resect, especially when the organ is cirrhotic. To remove tumors at this location, our group has developed a round high-frequency electrosurgical knife that allows hemispherical resection of the liver tissue. This study describes a new laparoscopic-assisted hepatectomy utilizing radiofrequency ablation of the tissue surrounding the tumor and high-frequency electrocautery. When compared with the laparoscopic hepatectomy, this new procedure seems to offer a safer, more effective, and less time-consuming means of resecting tumors on the liver surface. (c) 2005 Wiley-Liss, Inc.
Oke, Olaleke O; Magony, Andor; Anver, Himashi; Ward, Peter D; Jiruska, Premysl; Jefferys, John G R; Vreugdenhil, Martin
2010-04-01
Synchronization of neuronal activity in the visual cortex at low (30-70 Hz) and high gamma band frequencies (> 70 Hz) has been associated with distinct visual processes, but mechanisms underlying high-frequency gamma oscillations remain unknown. In rat visual cortex slices, kainate and carbachol induce high-frequency gamma oscillations (fast-gamma; peak frequency approximately 80 Hz at 37 degrees C) that can coexist with low-frequency gamma oscillations (slow-gamma; peak frequency approximately 50 Hz at 37 degrees C) in the same column. Current-source density analysis showed that fast-gamma was associated with rhythmic current sink-source sequences in layer III and slow-gamma with rhythmic current sink-source sequences in layer V. Fast-gamma and slow-gamma were not phase-locked. Slow-gamma power fluctuations were unrelated to fast-gamma power fluctuations, but were modulated by the phase of theta (3-8 Hz) oscillations generated in the deep layers. Fast-gamma was spatially less coherent than slow-gamma. Fast-gamma and slow-gamma were dependent on gamma-aminobutyric acid (GABA)(A) receptors, alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptors and gap-junctions, their frequencies were reduced by thiopental and were weakly dependent on cycle amplitude. Fast-gamma and slow-gamma power were differentially modulated by thiopental and adenosine A(1) receptor blockade, and their frequencies were differentially modulated by N-methyl-D-aspartate (NMDA) receptors, GluK1 subunit-containing receptors and persistent sodium currents. Our data indicate that fast-gamma and slow-gamma both depend on and are paced by recurrent inhibition, but have distinct pharmacological modulation profiles. The independent co-existence of fast-gamma and slow-gamma allows parallel processing of distinct aspects of vision and visual perception. The visual cortex slice provides a novel in vitro model to study cortical high-frequency gamma oscillations.
Vassilikos, Vassilios P; Mantziari, Lilian; Dakos, Georgios; Kamperidis, Vasileios; Chouvarda, Ioanna; Chatzizisis, Yiannis S; Kalpidis, Panagiotis; Theofilogiannakos, Efstratios; Paraskevaidis, Stelios; Karvounis, Haralambos; Mochlas, Sotirios; Maglaveras, Nikolaos; Styliadis, Ioannis H
2014-01-01
Wider QRS and left bundle branch block morphology are related to response to cardiac resynchronization therapy (CRT). A novel time-frequency analysis of the QRS complex may provide additional information in predicting response to CRT. Signal-averaged electrocardiograms were prospectively recorded, before CRT, in orthogonal leads and QRS decomposition in three frequency bands was performed using the Morlet wavelet transformation. Thirty eight patients (age 65±10years, 31 males) were studied. CRT responders (n=28) had wider baseline QRS compared to non-responders and lower QRS energies in all frequency bands. The combination of QRS duration and mean energy in the high frequency band had the best predicting ability (AUC 0.833, 95%CI 0.705-0.962, p=0.002) followed by the maximum energy in the high frequency band (AUC 0.811, 95%CI 0.663-0.960, p=0.004). Wavelet transformation of the QRS complex is useful in predicting response to CRT. © 2013.
Turn-over in pulsar spectra: From young pulsars to millisecond ones
NASA Astrophysics Data System (ADS)
Kijak, J.; Lewandowski, W.; Serylak, M.
2008-02-01
The evidence for turn-over in young pulsar radio spectra at high frequencies is presented. The frequency at which a spectrum shows the maximum flux density is called the peak frequency. This peak frequency appears to depend on pulsar age and dispersion measure. A possible relation with pulsar age is interesting. Millisecond pulsars, which are very old objects, may show no evidence for spectral turn-over down to 100 MHz. Some studied pulsars with turn-over at high frequencies have been shown to have very interesting interstellar environments. This could suggest that the turn-over phenomenon is associated with the enviromental conditions around the neutron stars, rahter than being related intrinsically with the radio emission mechanism. Although there are no earlier reports of such a connection, a more detailed study on larger sample of pulsars is needed to address this idea more quantitatively. In this context, future observations below 200 MHz using LOFAR will allow us to investigate turn-over in radio pulsar spectra.
Piai, Vitória; Roelofs, Ardi; Maris, Eric
2014-01-01
Two fundamental factors affecting the speed of spoken word production are lexical frequency and sentential constraint, but little is known about their timing and electrophysiological basis. In the present study, we investigated event-related potentials (ERPs) and oscillatory brain responses induced by these factors, using a task in which participants named pictures after reading sentences. Sentence contexts were either constraining or nonconstraining towards the final word, which was presented as a picture. Picture names varied in their frequency of occurrence in the language. Naming latencies and electrophysiological responses were examined as a function of context and lexical frequency. Lexical frequency is an index of our cumulative learning experience with words, so lexical-frequency effects most likely reflect access to memory representations for words. Pictures were named faster with constraining than nonconstraining contexts. Associated with this effect, starting around 400 ms pre-picture presentation, oscillatory power between 8 and 30 Hz was lower for constraining relative to nonconstraining contexts. Furthermore, pictures were named faster with high-frequency than low-frequency names, but only for nonconstraining contexts, suggesting differential ease of memory access as a function of sentential context. Associated with the lexical-frequency effect, starting around 500 ms pre-picture presentation, oscillatory power between 4 and 10 Hz was higher for high-frequency than for low-frequency names, but only for constraining contexts. Our results characterise electrophysiological responses associated with lexical frequency and sentential constraint in spoken word production, and point to new avenues for studying these fundamental factors in language production. © 2013 Published by Elsevier Ltd.
Fu, Zi-Ying; Zeng, Hong; Tang, Jia; Li, Jie; Li, Juan; Chen, Qi-Cai
2013-06-25
It has been reported that the frequency modulation (FM) or FM direction sensitivity and forward masking of central auditory neurons are related with the neural inhibition, but there are some arguments, because no direct evidence of inhibitory synaptic input was obtained in previous studies using extracellular recording. In the present study, we studied the relation between FM direction sensitivity and forward masking of the inferior collicular (IC) neurons using in vivo intracellular recordings in 20 Mus musculus Km mice. Thirty seven with complete data among 93 neurons were analyzed and discussed. There was an inhibitory area which consisted of inhibitory postsynaptic potentials (IPSP) at high frequency side of frequency tuning of up-sweep FM (FMU) sensitive neurons (n = 12) and at low frequency side of frequency tuning of down-sweep FM (FMD) selective neurons (n = 8), while there was no any inhibitory area at both sides of frequency tuning of non-FM sweep direction (FMN) sensitive neurons (n = 17). Therefore, these results show that the inhibitory area at low or high frequency side of frequency tuning is one of the mechanisms for forming FM sweep direction sensitivity of IC neurons. By comparison of forward masking produced by FMU and FMD sound stimuli in FMU, FMD and FMN neurons, the selective FM sounds could produce stronger forward masking than the non-selective in FMU and FMD neurons, while there was no forward masking difference between FMU and FMD stimuli in the FMN neurons. We suggest that the post-action potential IPSP is a potential mechanism for producing stronger forward masking in FMU and FMD neurons.
NASA Astrophysics Data System (ADS)
Haris, A.; Pradana, G. S.; Riyanto, A.
2017-07-01
Tectonic setting of the Bird Head Papua Island becomes an important model for petroleum system in Eastern part of Indonesia. The current exploration has been started since the oil seepage finding in Bintuni and Salawati Basin. The biogenic gas in shallow layer turns out to become an interesting issue in the hydrocarbon exploration. The hydrocarbon accumulation appearance in a shallow layer with dry gas type, appeal biogenic gas for further research. This paper aims at delineating the sweet spot hydrocarbon potential in shallow layer by applying the spectral decomposition technique. The spectral decomposition is decomposing the seismic signal into an individual frequency, which has significant geological meaning. One of spectral decomposition methods is Continuous Wavelet Transform (CWT), which transforms the seismic signal into individual time and frequency simultaneously. This method is able to make easier time-frequency map analysis. When time resolution increases, the frequency resolution will be decreased, and vice versa. In this study, we perform low-frequency shadow zone analysis in which the amplitude anomaly at a low frequency of 15 Hz was observed and we then compare it to the amplitude at the mid (20 Hz) and the high-frequency (30 Hz). The appearance of the amplitude anomaly at a low frequency was disappeared at high frequency, this anomaly disappears. The spectral decomposition by using CWT algorithm has been successfully applied to delineate the sweet spot zone.
Melmer, Tamara; Amirshahi, Seyed A.; Koch, Michael; Denzler, Joachim; Redies, Christoph
2013-01-01
The spatial characteristics of letters and their influence on readability and letter identification have been intensely studied during the last decades. There have been few studies, however, on statistical image properties that reflect more global aspects of text, for example properties that may relate to its aesthetic appeal. It has been shown that natural scenes and a large variety of visual artworks possess a scale-invariant Fourier power spectrum that falls off linearly with increasing frequency in log-log plots. We asked whether images of text share this property. As expected, the Fourier spectrum of images of regular typed or handwritten text is highly anisotropic, i.e., the spectral image properties in vertical, horizontal, and oblique orientations differ. Moreover, the spatial frequency spectra of text images are not scale-invariant in any direction. The decline is shallower in the low-frequency part of the spectrum for text than for aesthetic artworks, whereas, in the high-frequency part, it is steeper. These results indicate that, in general, images of regular text contain less global structure (low spatial frequencies) relative to fine detail (high spatial frequencies) than images of aesthetics artworks. Moreover, we studied images of text with artistic claim (ornate print and calligraphy) and ornamental art. For some measures, these images assume average values intermediate between regular text and aesthetic artworks. Finally, to answer the question of whether the statistical properties measured by us are universal amongst humans or are subject to intercultural differences, we compared images from three different cultural backgrounds (Western, East Asian, and Arabic). Results for different categories (regular text, aesthetic writing, ornamental art, and fine art) were similar across cultures. PMID:23554592
Hack, Jason B; Goldlust, Eric J; Gibbs, Frantz; Zink, Brian
2014-03-01
Emergency Departments (EDs) care for thousands of alcohol-intoxicated patients annually. No clinically relevant bedside measures currently exist to describe degree of impairment. To assess a group of bedside tests ("Hack's Impairment Index [HII] score") that applies a numerical value to the degree of alcohol-induced impairment in ED patients. A six-month retrospective review of HII score data was performed in a convenience sample of 293 intoxicated ED patients. Patients were scored 0-4 on five tasks, divided by the maximum score (20 if all tasks completed), every 2 hours; and classified by the number of visits: Low-frequency (1 visit); Medium-frequency (2 visits); High-frequency (≥3 visits). Correlations were assessed between HII score, healthcare provider judgment of intoxication, and measured alcohol levels. Study patients had 513 visits; 236 were low-frequency, 26 middle-frequency and 31 high-frequency. Clinical assessment and HII score were strongly correlated (Spearman's rho = 0.82, p < 0.001); clinical assessment and alcohol level less strongly so (rho = 0.49, p < 0.001). Among low-frequency patients, HII score and alcohol level were weakly correlated (r = 0.324, p < 0.001), with no such correlation among high-frequency visitors (r = -0.04, p = 0.89). The mean decline between serial HII scores was 0.126 (95% CI: 0.098-0.154). This pilot study shows the HII score can be performed at the bedside of alcohol-intoxicated patients. The HII declines in a reasonably predictable manner over time; and applies a quantitative, objective assessment of alcohol impairment.
Effect of dynamic hydrostatic pressure on rabbit intervertebral disc cells.
Kasra, Mehran; Goel, Vijay; Martin, James; Wang, Shea-Tien; Choi, Woosung; Buckwalter, Joseph
2003-07-01
The pathogenesis of vibration-induced disorders of intervertebral disc at the cellular level is largely unknown. The objective of this study was to establish a method to investigate the ranges of constructive and destructive hydrostatic loading frequencies and amplitudes in preventing or inducing extracellular disc matrix degradation. Using a hydraulic chamber, normal rabbit intervertebral disc cells were tested under dynamic hydrostatic loading. Monolayer cultures of disc outer annulus cells and 3-dimensional (3-D) alginate cultures of disc nucleus pulposus cells were tested. Effects of different loading amplitudes (3-D culture, 0-3 MPa; monolayer, 0-1.7 MPa) and frequencies (1-20 Hz) on disc collagen and protein metabolism were investigated by measuring 3H-proline-labeled proteins associated with the cells in the extracellular matrix and release of 3H-proline-labeled molecules into culture medium. High frequency and high amplitude hydrostatic stress stimulated collagen synthesis in cultures of outer annulus cells whereas the lower amplitude and frequency hydrostatic stress had little effect. For the same loading duration and repetition, neither treatment significantly affected the relative amount of protein released from the cell layers, indicating that protein degradation and stability were unaffected. In the 3-D nucleus culture, higher amplitude and frequency increased synthesis rate and lowered degradation. In this case, loading amplitude had a stronger influence on cell response than that of loading frequency. Considering the ranges of loading amplitude and frequency used in this study, short-term application of high loading amplitudes and frequencies was beneficial in stimulation of protein synthesis and reduction of protein degradation.
Michaud, Mark; Leong, Thomas; Swiergon, Piotr; Juliano, Pablo; Knoerzer, Kai
2015-09-01
This work validated, in a higher frequency range, the theoretical predictions made by Boyle around 1930, which state that the optimal transmission of sound pressure through a metal plate occurs when the plate thickness equals a multiple of half the wavelength of the sound wave. Several reactor design parameters influencing the transmission of high frequency ultrasonic waves through a stainless steel plate were examined. The transmission properties of steel plates of various thicknesses (1-7 mm) were studied for frequencies ranging from 400 kHz to 2 MHz and at different distances between plates and transducers. It was shown that transmission of sound pressure through a steel plate showed high dependence of the thickness of the plate to the frequency of the sound wave (thickness ratio). Maximum sound pressure transmission of ∼ 60% of the incident pressure was observed when the ratio of the plate thickness to the applied frequency was a multiple of a half wavelength (2 MHz, 6mm stainless steel plate). In contrast, minimal sound pressure transmission (∼ 10-20%) was measured for thickness ratios that were not a multiple of a half wavelength. Furthermore, the attenuation of the sound pressure in the transmission region was also investigated. As expected, it was confirmed that higher frequencies have more pronounced sound pressure attenuation than lower frequencies. The spatial distribution of the sound pressure transmitted through the plate characterized by sonochemiluminescence measurements using luminol emission, supports the validity of the pressure measurements in this study. Copyright © 2015 Elsevier B.V. All rights reserved.
2012-01-01
Background Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digital video (AVI) files that runs on open-source software (ImageJ) coupled to Microsoft Excel, and to validate this by comparison to the direct measuring high-speed video recordings of respiratory and ependymal cilia. These models allowed comparison to cilia beating between 3 and 52 Hz. Methods Digital video files of motile ciliated ependymal (frequency range 34 to 52 Hz) and respiratory epithelial cells (frequency 3 to 18 Hz) were captured using a high-speed digital video recorder. To cover the range above between 18 and 37 Hz the frequency of ependymal cilia were slowed by the addition of the pneumococcal toxin pneumolysin. Measurements made directly by timing a given number of individual ciliary beat cycles were compared with those obtained using the automated ciliaFA system. Results The overall mean difference (± SD) between the ciliaFA and direct measurement high-speed digital imaging methods was −0.05 ± 1.25 Hz, the correlation coefficient was shown to be 0.991 and the Bland-Altman limits of agreement were from −1.99 to 1.49 Hz for respiratory and from −2.55 to 3.25 Hz for ependymal cilia. Conclusions A plugin for ImageJ was developed that extracts pixel intensities and performs fast Fourier transformation (FFT) using Microsoft Excel. The ciliaFA software allowed automated, high throughput measurement of respiratory and ependymal ciliary beat frequency (range 3 to 52 Hz) and avoids operator error due to selection bias. We have included free access to the ciliaFA plugin and installation instructions in Additional file 1 accompanying this manuscript that other researchers may use. PMID:23351276
Frequency-tunable superconducting resonators via nonlinear kinetic inductance
NASA Astrophysics Data System (ADS)
Vissers, M. R.; Hubmayr, J.; Sandberg, M.; Chaudhuri, S.; Bockstiegel, C.; Gao, J.
2015-08-01
We have designed, fabricated, and tested a frequency-tunable high-Q superconducting resonator made from a niobium titanium nitride film. The frequency tunability is achieved by injecting a DC through a current-directing circuit into the nonlinear inductor whose kinetic inductance is current-dependent. We have demonstrated continuous tuning of the resonance frequency in a 180 MHz frequency range around 4.5 GHz while maintaining the high internal quality factor Qi > 180 000. This device may serve as a tunable filter and find applications in superconducting quantum computing and measurement. It also provides a useful tool to study the nonlinear response of a superconductor. In addition, it may be developed into techniques for measurement of the complex impedance of a superconductor at its transition temperature and for readout of transition-edge sensors.
One-year audiologic monitoring of individuals exposed to the 1995 Oklahoma City bombing.
Van Campen, L E; Dennis, J M; Hanlin, R C; King, S B; Velderman, A M
1999-05-01
This longitudinal study evaluated subjective, behavioral, and objective auditory function in 83 explosion survivors. Subjects were evaluated quarterly for 1 year with conventional pure-tone and extended high-frequencies audiometry, otoscopic inspections, immittance and speech audiometry, and questionnaires. There was no obvious relationship between subject location and symptoms or test results. Tinnitus, distorted hearing, loudness sensitivity, and otalgia were common symptoms. On average, 76 percent of subjects had predominantly sensorineural hearing loss at one or more frequencies. Twenty-four percent of subjects required amplification. Extended high frequencies showed evidence of acoustic trauma even when conventional frequencies fell within the normal range. Males had significantly poorer responses than females across frequencies. Auditory status of the group was significantly compromised and unchanged at the end of 1-year postblast.
Coexistence of gamma and high-frequency oscillations in rat medial entorhinal cortex in vitro
Cunningham, M O; Halliday, David M; Davies, Ceri H; Traub, Roger D; Buhl, Eberhard H; Whittington, Miles A
2004-01-01
High frequency oscillations (> 80–90 Hz) occur in neocortex and hippocampus in vivo where they are associated with specific behavioural states and more classical EEG frequency bands. In the hippocampus in vitro these oscillations can occur in the absence of pyramidal neuronal somatodendritic compartments and are temporally correlated with on-going, persistent gamma frequency oscillations. Their occurrence in the hippocampus is dependent on gap-junctional communication and it has been suggested that these high frequency oscillations originate as collective behaviour in populations of electrically coupled principal cell axonal compartments. Here we demonstrate that the superficial layers of medial entorhinal cortex can also generate high frequency oscillations associated with gamma rhythms. During persistent gamma frequency oscillations high frequency oscillations occur with a high bispectral coherence with the field gamma activity. Bursts of high frequency oscillations are temporally correlated with both the onset of compound excitatory postsynaptic potentials in fast-spiking interneurones and spikelet potentials in both pyramidal and stellate principal neurones. Both the gamma frequency and high frequency oscillations were attenuated by the gap junction blocker carbenoxolone. These data suggest that high frequency oscillations may represent the substrate for phasic drive to interneurones during persistent gamma oscillations in the medial entorhinal cortex. PMID:15254156
NASA Astrophysics Data System (ADS)
Wu, Shuang; Kanada, Isao; Mewes, Tim; Mewes, Claudia; Mankey, Gary; Ariake, Yusuke; Suzuki, Takao
Soft ferrites have been extensively and intensively applied for high frequency device applications. Among them, Ba-ferrites substituted by Mn and Ti are particularly attractive as future soft magnetic material candidates for advanced high frequency device applications. However, very little has been known as to the intrinsic magnetic properties, such as damping parameter, which is crucial to develop high frequency devices. In the present study, much effort has been focused on fabrication of single crystal Ba-ferrites and measurements of damping parameter by FMR. Ba-ferrite samples consisted of many grains with various sizes have been prepared. The saturation magnetization and the magnetic anisotropy field of the sample are in reasonable agreement with the values in literature. The resonances positions in the FMR spectra over a wide frequency range also comply with theoretical predictions. However, the complex resonance shapes observed makes it difficult to extract dynamic magnetic property. Possible reasons are the demagnetization field originating from irregular sample shape or existence of multiple grains in the samples. S.W. acknowledges the support under the TDK Scholar Program.
Transparent megahertz circuits from solution-processed composite thin films.
Liu, Xingqiang; Wan, Da; Wu, Yun; Xiao, Xiangheng; Guo, Shishang; Jiang, Changzhong; Li, Jinchai; Chen, Tangsheng; Duan, Xiangfeng; Fan, Zhiyong; Liao, Lei
2016-04-21
Solution-processed amorphous oxide semiconductors have attracted considerable interest in large-area transparent electronics. However, due to its relative low carrier mobility (∼10 cm(2) V(-1) s(-1)), the demonstrated circuit performance has been limited to 800 kHz or less. Herein, we report solution-processed high-speed thin-film transistors (TFTs) and integrated circuits with an operation frequency beyond the megahertz region on 4 inch glass. The TFTs can be fabricated from an amorphous indium gallium zinc oxide/single-walled carbon nanotube (a-IGZO/SWNT) composite thin film with high yield and high carrier mobility of >70 cm(2) V(-1) s(-1). On-chip microwave measurements demonstrate that these TFTs can deliver an unprecedented operation frequency in solution-processed semiconductors, including an extrinsic cut-off frequency (f(T) = 102 MHz) and a maximum oscillation frequency (f(max) = 122 MHz). Ring oscillators further demonstrated an oscillation frequency of 4.13 MHz, for the first time, realizing megahertz circuit operation from solution-processed semiconductors. Our studies represent an important step toward high-speed solution-processed thin film electronics.
Design considerations of Miller oscillators for high-sensitivity QCM sensors in damping media.
Rodriguez-Pardo, Loreto; Fariña, Jose; Gabrielli, Claude; Perrot, Hubert; Brendel, Remi
2007-10-01
In this paper, a new contribution to the design of quartz crystal oscillators for high-sensitivity microbalance sensors used in liquid media is presented. The oscillation condition for a Miller configuration was studied to work in a wide dynamic range of the resonator losses. The equations relating the values of the active and passive components with the maximum supported damping and mass were obtained. Also, the conditions to obtain a stable frequency according to the resonator damping (R(Q)), the static capacity (Cp) and the filter frequency (f(F)) were found. Under these conditions, the circuit oscillation frequency will be proportional to the resonant series frequency and does not depend on the previous parameters (R(Q), f(F), and Cp). If these conditions cannot be satisfied, the expression of the oscillation frequency is given and the discrimination of these effects is obtained through resonator frequency measurements.
Synchronization of electrically coupled micromechanical oscillators with a frequency ratio of 3:1
NASA Astrophysics Data System (ADS)
Pu, Dong; Wei, Xueyong; Xu, Liu; Jiang, Zhuangde; Huan, Ronghua
2018-01-01
In this Letter, synchronization of micromechanical oscillators with a frequency ratio of 3:1 is reported. Two electrically coupled piezoresistive micromechanical oscillators are built for the study, and their oscillation frequencies are tuned via the Joule heating effect to find out the synchronization region. Experimental results show that the larger coupling strength or bias driving voltage is applied and a wider synchronization region is obtained. Interestingly, however, the oscillator's frequency tunability is dramatically reduced from -809.1 Hz/V to -23.1 Hz/V when synchronization is reached. A nearly 10-fold improvement of frequency stability at 1 s is observed from one of the synchronized oscillators, showing a comparable performance of the other. The stable high order synchronization of micromechanical oscillators is helpful to design high performance resonant sensors with a better frequency resolution and a larger scale factor.
Bermúdez-Cuamatzin, Eira; Ríos-Chelén, Alejandro A; Gil, Diego; Garcia, Constantino Macías
2011-02-23
Research has shown that bird songs are modified in different ways to deal with urban noise and promote signal transmission through noisy environments. Urban noise is composed of low frequencies, thus the observation that songs have a higher minimum frequency in noisy places suggests this is a way of avoiding noise masking. Most studies are correlative and there is as yet little experimental evidence that this is a short-term mechanism owing to individual plasticity. Here we experimentally test if house finches (Carpodacus mexicanus) can modulate the minimum frequency of their songs in response to different noise levels. We exposed singing males to three continuous treatments: low-high-low noise levels. We found a significant increase in minimum frequency from low to high and a decrement from high to low treatments. We also found that this was mostly achieved by modifying the frequency of the same low-frequency syllable types used in the different treatments. When different low-frequency syllables were used, those sung during the noisy condition were longer than the ones sang during the quiet condition. We conclude that house finches modify their songs in several ways in response to urban noise, thus providing evidence of a short-term acoustic adaptation.
Serial recall, word frequency, and mixed lists: the influence of item arrangement.
Miller, Leonie M; Roodenrys, Steven
2012-11-01
Studies of the effect of word frequency in the serial recall task show that lists of high-frequency words are better recalled than lists of low-frequency words; however, when high- and low-frequency words are alternated within a list, there is no difference in the level of recall for the two types of words, and recall is intermediate between lists of pure frequency. This pattern has been argued to arise from the development of a network of activated long-term representations of list items that support the redintegration of all list items in a nondirectional and nonspecific way. More recently, it has been proposed that the frequency effect might be a product of the coarticulation of items at word boundaries and their influence on rehearsal rather than a consequence of memory representations. The current work examines recall performance in mixed lists of an equal number of high- and low-frequency items arranged in contiguous segments (i.e., HHHLLL and LLLHHH), under quiet and articulatory suppression conditions, to test whether the effect is (a) nondirectional and (b) dependent on articulatory processes. These experiments demonstrate that neither explanation is satisfactory, although the results suggest that the effect is mnemonic. A language-based approach to short-term memory is favored with emphasis on the role of speech production processes at output.
Effect of laser pulse shaping parameters on the fidelity of quantum logic gates.
Zaari, Ryan R; Brown, Alex
2012-09-14
The effect of varying parameters specific to laser pulse shaping instruments on resulting fidelities for the ACNOT(1), NOT(2), and Hadamard(2) quantum logic gates are studied for the diatomic molecule (12)C(16)O. These parameters include varying the frequency resolution, adjusting the number of frequency components and also varying the amplitude and phase at each frequency component. A time domain analytic form of the original discretized frequency domain laser pulse function is derived, providing a useful means to infer the resulting pulse shape through variations to the aforementioned parameters. We show that amplitude variation at each frequency component is a crucial requirement for optimal laser pulse shaping, whereas phase variation provides minimal contribution. We also show that high fidelity laser pulses are dependent upon the frequency resolution and increasing the number of frequency components provides only a small incremental improvement to quantum gate fidelity. Analysis through use of the pulse area theorem confirms the resulting population dynamics for one or two frequency high fidelity laser pulses and implies similar dynamics for more complex laser pulse shapes. The ability to produce high fidelity laser pulses that provide both population control and global phase alignment is attributed greatly to the natural evolution phase alignment of the qubits involved within the quantum logic gate operation.
Peak high-frequency HRV and peak alpha frequency higher in PTSD.
Wahbeh, Helané; Oken, Barry S
2013-03-01
Posttraumatic stress disorder (PTSD) is difficult to treat and current PTSD treatments are not effective for all people. Despite limited evidence for its efficacy, some clinicians have implemented biofeedback for PTSD treatment. As a first step in constructing an effective biofeedback treatment program, we assessed respiration, electroencephalography (EEG) and heart rate variability (HRV) as potential biofeedback parameters for a future clinical trial. This cross-sectional study included 86 veterans; 59 with and 27 without PTSD. Data were collected on EEG measures, HRV, and respiration rate during an attentive resting state. Measures were analyzed to assess sensitivity to PTSD status and the relationship to PTSD symptoms. Peak alpha frequency was higher in the PTSD group (F(1,84) = 6.14, p = 0.01). Peak high-frequency HRV was lower in the PTSD group (F(2,78) = 26.5, p < 0.00005) when adjusting for respiration rate. All other EEG and HRV measures and respiration were not different between groups. Peak high-frequency HRV and peak alpha frequency are sensitive to PTSD status and may be potential biofeedback parameters for future PTSD clinical trials.
Influence of Reduced Graphene Oxide on Effective Absorption Bandwidth Shift of Hybrid Absorbers.
Ameer, Shahid; Gul, Iftikhar Hussain
2016-01-01
The magnetic nanoparticle composite NiFe2O4 has traditionally been studied for high-frequency microwave absorption with marginal performance towards low-frequency radar bands (particularly L and S bands). Here, NiFe2O4 nanoparticles and nanohybrids using large-diameter graphene oxide (GO) sheets are prepared via solvothermal synthesis for low-frequency wide bandwidth shielding (L and S radar bands). The synthesized materials were characterized using XRD, SEM, FTIR and microwave magneto dielectric spectroscopy. The dimension of these solvothermally synthesized pristine particles and hybrids lies within 30-58 nm. Microwave magneto-dielectric spectroscopy was performed in the low-frequency region in the 1 MHz-3 GHz spectrum. The as-synthesized pristine nanoparticles and hybrids were found to be highly absorbing for microwaves throughout the L and S radar bands (< -10 dB from 1 MHz to 3 GHz). This excellent microwave absorbing property induced by graphene sheet coupling shows application of these materials with absorption bandwidth which is tailored such that these could be used for low frequency. Previously, these were used for high frequency absorptions (typically > 4 GHz) with limited selective bandwidth.
Peak High-Frequency HRV and Peak Alpha Frequency Higher in PTSD
Oken, Barry S.
2012-01-01
Posttraumatic stress disorder (PTSD) is difficult to treat and current PTSD treatments are not effective for all people. Despite limited evidence for its efficacy, some clinicians have implemented biofeedback for PTSD treatment. As a first step in constructing an effective biofeedback treatment program, we assessed respiration, electroencephalography (EEG) and heart rate variability (HRV) as potential biofeedback parameters for a future clinical trial. This cross-sectional study included 86 veterans; 59 with and 27 without PTSD. Data were collected on EEG measures, HRV, and respiration rate during an attentive resting state. Measures were analyzed to assess sensitivity to PTSD status and the relationship to PTSD symptoms. Peak alpha frequency was higher in the PTSD group (F(1,84) = 6.14, p = 0.01). Peak high-frequency HRV was lower in the PTSD group (F(2,78) = 26.5, p<0.00005) when adjusting for respiration rate. All other EEG and HRV measures and respiration were not different between groups. Peak high-frequency HRV and peak alpha frequency are sensitive to PTSD status and may be potential biofeedback parameters for future PTSD clinical trials. PMID:23178990
Bazzotti, L
1999-01-01
On a population of 52 subjects surface electromyographic recordings of temporals and masseters, simultaneously with mandible dynamic of closure and clenching, were performed, in order to study tension and frequency behaviour in three postural conditions: rest, isotonic and isometric contractions. Frequency was studied using the median resulting from FFT calculation, and a new computing method, which presents the proportion of frequencies making up the whole EMG signal, by steps of 50 Hz. Tension was calculated as well. The results permit us to draw the following conclusions: 1. a period of EMG silence was present in 51 of 52 subjects at mandible closure (SPA--Silent Period Area); 2. SPA onset was before teeth contact (22.5 msec., during the motion of the mandible), while its end was after closure (10.2 msec., during motionless phase of clenching). This allowed to use the SPA as a tool to clearly distinguish isotonic from isometric contraction; 3. the comparison of tension and frequency, expressed as median, showed that at rest a muscle presents low frequency and low tension. In active contraction both increase their values. Nevertheless, in active contraction, while no differences were found in frequency behaviour, tension showed a difference: although higher than at rest, isotonic contraction presented lower values than during isometric contraction; 4. the study performed by the new program showed that the low frequency at rest was due to the high proportion (30-40%) of frequencies of less than 50 Hz, while the increase at function was due to the parallel increase of frequencies comprised between 100 and 250 Hz. Because it is known that muscles are composed of fibers at low frequency and at high frequency of discharge, which play different functional roles, the last finding suggests that the mathematical analysis of the spectrum of frequencies, could provide a functional-histological image of the muscle.
Linear enamel hypoplasia in the great apes: analysis by genus and locality.
Hannibal, Darcy Lee; Guatelli-Steinberg, Debbie
2005-05-01
Most studies report a high prevalence of linear enamel hypoplasia (LEH) in the great apes relative to other nonhuman primates and some human populations. It is unclear if this difference is a direct result of poor health status for the great apes, or if it represents differential incidence due to a lower threshold (sensu Goodman and Rose, 1990 Am. J. Phys. Anthropol. [suppl.] 33:59-110) for the occurrence of enamel hypoplasia among great apes. This study uses the Smithsonian National Museum of Natural History's great ape collection to examine the prevalence of LEH, the most common type of hypoplasia observed. Frequencies of LEH are reported, as well as analyses by taxa and provenience. The study sample consists of 136 specimens and includes 41 gorillas, 25 chimpanzees, and 70 orangutans. Analyses of frequencies are presented for both individuals and teeth by taxonomic category and locality. Among the individuals in this study, 63.97% are affected by LEH. Overall, gorillas (29.27%) exhibit lower frequencies of LEH than chimpanzees (68.00%) and orangutans (82.86%). There is a marked difference in LEH frequencies between mountain and lowland gorillas. There is no difference in LEH frequencies between Sumatran and Bornean orangutans. A range of variation for the great apes in enamel hypoplasia frequencies is found when taxon and locality are considered. It is likely that both biological and environmental factors influence the high frequencies of enamel hypoplasia exhibited in the great apes. Copyright 2004 Wiley-Liss, Inc.
Chang, Xing; Zhou, Xin; Luo, Linzhi; Yang, Chengjia; Pan, Hui; Zhang, Shuyang
2017-09-12
This study aimed to identify hotspots in research on clinical competence measurements from 2012 to 2016. The authors retrieved literature published between 2012 and 2016 from PubMed using selected medical subject headings (MeSH) terms. They used BibExcel software to generate high-frequency MeSH terms and identified hotspots by co-word analysis and cluster analysis. The authors searched 588 related articles and identified 31 high-frequency MeSH terms. In addition, they obtained 6 groups of high-frequency MeSH terms that reflected the domain hotspots. This study identified 6 hotspots of domain research, including studies on influencing factors and perception evaluation, improving and developing measurement tools, feedback measurement, measurement approaches based on computer simulation, the measurement of specific students in different learning phases, and the measurement of students' communication ability. All of these research topics could provide useful information for educators and researchers to continually conduct in-depth studies.
High-frequency trigger generators for CuBr-laser high voltage pumping source
NASA Astrophysics Data System (ADS)
Torgaev, S.; Kozhemyak, O.; Yaroslavtsev, E.; Trigub, M.; Musorov, I.; Chertikhina, D.
2016-04-01
In this paper the circuits of high frequency trigger generators of pulses of the nanosecond duration are presented. A detailed study of a generator based on the avalanche transistor with the use of a coaxial cable instead of a capacitor is described. This circuit showed advanced characteristics of the output pulses. A circuit of a generator built on high-speed digital components is also considered. The basic advantages and disadvantages of both generators are presented in this paper.
NASA Astrophysics Data System (ADS)
Juillard, J.; Brenes, A.
2018-05-01
In this paper, the frequency stability of high-Q electrostatically-actuated MEMS oscillators with cubic restoring forces, and its relation with the amplitude, the phase and the shape of the excitation waveform, is studied. The influence on close-to-the carrier frequency noise of additive processes (such as thermomechanical noise) or parametric processes (bias voltage fluctuations, feedback phase fluctuations, feedback level fluctuations) is taken into account. It is shown that the optimal operating conditions of electrostatically-actuated MEMS oscillators are highly waveform-dependent, a factor that is largely overlooked in the existing literature. This simulation-based study covers the cases of harmonic and pulsed excitation of a parallel-plate capacitive MEMS resonator.
Astrosat/LAXPC Reveals the High-energy Variability of GRS 1915+105 in the X Class
NASA Astrophysics Data System (ADS)
Yadav, J. S.; Misra, Ranjeev; Verdhan Chauhan, Jai; Agrawal, P. C.; Antia, H. M.; Pahari, Mayukh; Dedhia, Dhiraj; Katoch, Tilak; Madhwani, P.; Manchanda, R. K.; Paul, B.; Shah, Parag; Ishwara-Chandra, C. H.
2016-12-01
We present the first quick look analysis of data from nine AstroSat's Large Area X-ray Proportional Counter (LAXPC) observations of GRS 1915+105 during 2016 March when the source had the characteristics of being in the Radio-quiet χ class. We find that a simple empirical model of a disk blackbody emission, with Comptonization and a broad Gaussian Iron line can fit the time-averaged 3-80 keV spectrum with a systematic uncertainty of 1.5% and a background flux uncertainty of 4%. A simple dead time corrected Poisson noise level spectrum matches well with the observed high-frequency power spectra till 50 kHz and as expected the data show no significant high-frequency (\\gt 20 {Hz}) features. Energy dependent power spectra reveal a strong low-frequency (2-8 Hz) quasi-periodic oscillation and its harmonic along with broadband noise. The QPO frequency changes rapidly with flux (nearly 4 Hz in ˜5 hr). With increasing QPO frequency, an excess noise component appears significantly in the high-energy regime (\\gt 8 keV). At the QPO frequencies, the time-lag as a function of energy has a non-monotonic behavior such that the lags decrease with energy till about 15-20 keV and then increase for higher energies. These first-look results benchmark the performance of LAXPC at high energies and confirms that its data can be used for more sophisticated analysis such as flux or frequency-resolved spectro-timing studies.
NASA Astrophysics Data System (ADS)
Yun, Dong-Un; Lee, Sang-Kwon
2017-06-01
In this paper, we present a novel method for an objective evaluation of knocking noise emitted by diesel engines based on the temporal and frequency masking theory. The knocking sound of a diesel engine is a vibro-acoustic sound correlated with the high-frequency resonances of the engine structure and a periodic impulsive sound with amplitude modulation. Its period is related to the engine speed and includes specific frequency bands related to the resonances of the engine structure. A knocking sound with the characteristics of a high-frequency impulsive wave can be masked by low-frequency sounds correlated with the harmonics of the firing frequency and broadband noise. The degree of modulation of the knocking sound signal was used for such objective evaluations in previous studies, without considering the masking effect. However, the frequency masking effect must be considered for the objective evaluation of the knocking sound. In addition to the frequency masking effect, the temporal masking effect occurs because the period of the knocking sound changes according to the engine speed. Therefore, an evaluation method considering the temporal and frequency masking effect is required to analyze the knocking sound objectively. In this study, an objective evaluation method considering the masking effect was developed based on the masking theory of sound and signal processing techniques. The method was applied successfully for the objective evaluation of the knocking sound of a diesel engine.
Ontogeny and control of the heart rate power spectrum in the last third of gestation in fetal sheep.
Koome, Miriam E; Bennet, Laura; Booth, Lindsea C; Davidson, Joanne O; Wassink, Guido; Gunn, Alistair Jan
2014-01-01
Power spectral analysis of fetal heart rate variability has been proposed to provide a non-invasive estimate of autonomic balance. However, there are few systematic data before birth. We therefore examined developmental changes in the frequency power spectrum at very low (0-0.04 Hz), low (0.04-0.15 Hz) and high frequencies (0.15-0.4 Hz), as well as the ratio of low- to high-frequency power (LF/HF), in chronically catheterized, healthy fetal sheep at 0.6 (n = 8), 0.7 (n = 7) and 0.8 gestational age (ga; n = 11). In a second study, 0.8 ga fetuses received either atropine (4.8 mg bolus, then 4.8 mg h(-1) for 30 min, n = 6) or 6-hydroxydopamine (20 mg ml(-1) at 2.5 ml h(-1) for 3 h; n = 9). Data were analysed by sleep state, defined by low-voltage-high-frequency (LV) or high-voltage-low-frequency (HV) EEG. Total spectral power increased with gestational age (P < 0.05), while LF/HF decreased from 0.6 to 0.7 ga. At 0.8 ga, heart rate and LF/HF were significantly higher during HV than LV sleep (P < 0.05). Consistent with this, although total spectral power was not significantly greater during HV sleep, there was a significant interaction between sleep state and frequency band (P = 0.02). Both atropine (P = 0.05) and 6-hydroxydopamine (P < 0.05) were associated with an overall reduction in spectral power but no significant effect on the LF/HF ratio. This study does not support substantial, consistent differences between the frequencies of sympathetic and parasympathetic activity in late-gestation fetal sheep.
Visual information processing of faces in body dysmorphic disorder.
Feusner, Jamie D; Townsend, Jennifer; Bystritsky, Alexander; Bookheimer, Susan
2007-12-01
Body dysmorphic disorder (BDD) is a severe psychiatric condition in which individuals are preoccupied with perceived appearance defects. Clinical observation suggests that patients with BDD focus on details of their appearance at the expense of configural elements. This study examines abnormalities in visual information processing in BDD that may underlie clinical symptoms. To determine whether patients with BDD have abnormal patterns of brain activation when visually processing others' faces with high, low, or normal spatial frequency information. Case-control study. University hospital. Twelve right-handed, medication-free subjects with BDD and 13 control subjects matched by age, sex, and educational achievement. Intervention Functional magnetic resonance imaging while performing matching tasks of face stimuli. Stimuli were neutral-expression photographs of others' faces that were unaltered, altered to include only high spatial frequency visual information, or altered to include only low spatial frequency visual information. Blood oxygen level-dependent functional magnetic resonance imaging signal changes in the BDD and control groups during tasks with each stimulus type. Subjects with BDD showed greater left hemisphere activity relative to controls, particularly in lateral prefrontal cortex and lateral temporal lobe regions for all face tasks (and dorsal anterior cingulate activity for the low spatial frequency task). Controls recruited left-sided prefrontal and dorsal anterior cingulate activity only for the high spatial frequency task. Subjects with BDD demonstrate fundamental differences from controls in visually processing others' faces. The predominance of left-sided activity for low spatial frequency and normal faces suggests detail encoding and analysis rather than holistic processing, a pattern evident in controls only for high spatial frequency faces. These abnormalities may be associated with apparent perceptual distortions in patients with BDD. The fact that these findings occurred while subjects viewed others' faces suggests differences in visual processing beyond distortions of their own appearance.
NASA Technical Reports Server (NTRS)
Kim, Frederick D.
1992-01-01
Frequency responses generated from a high-order linear model of the UH-60 Black Hawk have shown that the propulsion system influences significantly the vertical and yaw dynamics of the aircraft at frequencies important to high-bandwidth control law designs. The inclusion of the propulsion system comprises the latest step in the development of a high-order linear model of the UH-60 that models additionally the dynamics of the fuselage, rotor, and inflow. A complete validation study of the linear model is presented in the frequency domain for both on-axis and off-axis coupled responses in the hoverflight condition, and on-axis responses for forward speeds of 80 and 120 knots.
Richard, Nelly; Laursen, Bettina; Grupe, Morten; Drewes, Asbjørn M; Graversen, Carina; Sørensen, Helge B D; Bastlund, Jesper F
2017-04-01
Active auditory oddball paradigms are simple tone discrimination tasks used to study the P300 deflection of event-related potentials (ERPs). These ERPs may be quantified by time-frequency analysis. As auditory stimuli cause early high frequency and late low frequency ERP oscillations, the continuous wavelet transform (CWT) is often chosen for decomposition due to its multi-resolution properties. However, as the conventional CWT traditionally applies only one mother wavelet to represent the entire spectrum, the time-frequency resolution is not optimal across all scales. To account for this, we developed and validated a novel method specifically refined to analyse P300-like ERPs in rats. An adapted CWT (aCWT) was implemented to preserve high time-frequency resolution across all scales by commissioning of multiple wavelets operating at different scales. First, decomposition of simulated ERPs was illustrated using the classical CWT and the aCWT. Next, the two methods were applied to EEG recordings obtained from prefrontal cortex in rats performing a two-tone auditory discrimination task. While only early ERP frequency changes between responses to target and non-target tones were detected by the CWT, both early and late changes were successfully described with strong accuracy by the aCWT in rat ERPs. Increased frontal gamma power and phase synchrony was observed particularly within theta and gamma frequency bands during deviant tones. The study suggests superior performance of the aCWT over the CWT in terms of detailed quantification of time-frequency properties of ERPs. Our methodological investigation indicates that accurate and complete assessment of time-frequency components of short-time neural signals is feasible with the novel analysis approach which may be advantageous for characterisation of several types of evoked potentials in particularly rodents.
The study of microstrip antenna arrays and related problems
NASA Technical Reports Server (NTRS)
Lo, R. Q.
1984-01-01
The work on rectangular microstrip antennas for dual frequency operation is reported on. The principle of this approach is based on the excitation of a patch for two or more different modes which correspond to different frequencies. However, for a given geometry, the modal frequencies have a fixed relationship; therefore, the usefulness of such a design is greatly limited. In this study three different methods have been contrived to control the frequency ratio over a wide range. First, as found prevously, if shorting pins are inserted at certain locations in the patch, the low frequency can be raised substantially. Second, if slots are cut in the patch, the high frequency can be lowered considerably. By using both techniques, the two frequency ratio can be varied approximately from 3 to 1.3. After that, the addition of more pins or slots becomes ineffective.
Frequency of Use Leads to Automaticity of Production: Evidence from Repair in Conversation
ERIC Educational Resources Information Center
Kapatsinski, Vsevolod
2010-01-01
In spontaneous speech, speakers sometimes replace a word they have just produced or started producing by another word. The present study reports that in these replacement repairs, low-frequency replaced words are more likely to be interrupted prior to completion than high-frequency words, providing support to the hypothesis that the production of…
Frequency-dependent solvent friction and torsional damping in liquid 1,2-difluoroethane
NASA Astrophysics Data System (ADS)
MacPhail, Richard A.; Monroe, Frances C.
1991-04-01
We have used Raman spectroscopy to study the torsional dynamics, rotational dynamics, and conformational solvation energy of liquid 1,2-difluoroethane. From the Raman intensities, we obtain Δ H(g-t) = -2.4±0.1 kcal/mol, indicating strong dipolar solvation of the gauche conformer. We analyze the Raman linewidths of the CCF bending bands to obtain the zero-frequency torsional damping coefficient or well friction for the gauche conformer, and from the linewidth of the torsion band we obtain the friction evaluated at the torsional frequency. The zero-frequency well friction shows deviations from hydrodynamic behavior reminiscent of those observed for barrier friction, whereas the high-frequency friction is considerably smaller in magnitude and independent of temperature and viscosity. The zero-frequency torsional friction correlates linearly with the rotational friction. It is argued that the small amplitude of the torsional fluctuations emphasizes the short distance, or high wavevector components of the solvent friction. Dielectric friction apparently does not contribute to the torsional friction at the observed frequencies.
Franco, O.S.; Paulitsch, F.S.; Pereira, A.P.C.; Teixeira, A.O.; Martins, C.N.; Silva, A.M.V.; Plentz, R.D.M.; Irigoyen, M.C.; Signori, L.U.
2014-01-01
Transcutaneous electrical nerve stimulation (TENS) is a type of therapy used primarily for analgesia, but also presents changes in the cardiovascular system responses; its effects are dependent upon application parameters. Alterations to the cardiovascular system suggest that TENS may modify venous vascular response. The objective of this study was to evaluate the effects of TENS at different frequencies (10 and 100 Hz) on venous vascular reactivity in healthy subjects. Twenty-nine healthy male volunteers were randomized into three groups: placebo (n=10), low-frequency TENS (10 Hz, n=9) and high-frequency TENS (100 Hz, n=10). TENS was applied for 30 min in the nervous plexus trajectory from the superior member (from cervical to dorsal region of the fist) at low (10 Hz/200 μs) and high frequency (100 Hz/200 μs) with its intensity adjusted below the motor threshold and intensified every 5 min, intending to avoid accommodation. Venous vascular reactivity in response to phenylephrine, acetylcholine (endothelium-dependent) and sodium nitroprusside (endothelium-independent) was assessed by the dorsal hand vein technique. The phenylephrine effective dose to achieve 70% vasoconstriction was reduced 53% (P<0.01) using low-frequency TENS (10 Hz), while in high-frequency stimulation (100 Hz), a 47% increased dose was needed (P<0.01). The endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) responses were not modified by TENS, which modifies venous responsiveness, and increases the low-frequency sensitivity of α1-adrenergic receptors and shows high-frequency opposite effects. These changes represent an important vascular effect caused by TENS with implications for hemodynamics, inflammation and analgesia. PMID:24820225
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mokerov, V. G., E-mail: vgmokerov@yandex.ru; Kuznetsov, A. L.; Fedorov, Yu. V.
2009-04-15
The N-Al{sub 0.27}Ga{sub 0.73}N/GaN High Electron Mobility Transistors (HEMTs) with different gate lengths L{sub g} (ranging from 170 nm to 0.5 {mu}m) and gate widths W{sub s} (ranging from 100 to 1200 {mu}m) have been studied. The S parameters have been measured; these parameters have been used to determine the current-gain cutoff frequency f{sub t}, the maximum oscillation frequency f{sub max}, and the power gain MSG/MAG and Mason's coefficients were investigated in the frequency range from 10 MHz to 67 GHz in relation to the gate length and gate width. It was found that the frequencies f{sub t} and f{submore » max} attain their maximum values of f{sub t} = 48 GHz and f{sub max} = 100 GHz at L{sub g} = 170 nm and W{sub g} = 100 {mu}m. The optimum values of W{sub g} and output power P out of the basic transistors have been determined for different frequencies of operation. It has also been demonstrated that the 170 nm Al{sub 0.27}Ga{sub 0.73}N/GaN HEMT technology provides both good frequency characteristics and high breakdown voltages and is very promising for high-frequency applications (up to 40 GHz)« less
NASA Astrophysics Data System (ADS)
Sborikas, Martynas; Wegener, Michael
2013-12-01
Ferroelectrets are piezoelectric materials suitable for acoustic applications such as airborne ultrasonic transducers. Typical ferroelectrets exhibit resonance frequencies in the high kHz to low MHz range. In order to decrease the transducer resonance frequencies to the low kHz range, processes such as gas-diffusion expansion and electric charging were adjusted to cellular films which are initially twice as thick as in earlier studies. The demonstrated film expansion and electric charging lead to mechanically soft cellular structures which show high piezoelectric activities with coefficients up to 130 pC/N. Due to the simultaneously increased film thicknesses, the resonance frequencies are lowered down to about 233 kHz.
Low-frequency noise reduction of lightweight airframe structures
NASA Technical Reports Server (NTRS)
Getline, G. L.
1976-01-01
The results of an experimental study to determine the noise attenuation characteristics of aircraft type fuselage structural panels were presented. Of particular interest was noise attenuation at low frequencies, below the fundamental resonances of the panels. All panels were flightweight structures for transport type aircraft in the 34,050 to 45,400 kg (75,000 to 100,000 pounds) gross weight range. Test data include the results of vibration and acoustic transmission loss tests on seven types of isotropic and orthotropically stiffened, flat and curved panels. The results show that stiffness controlled acoustically integrated structures can provide very high noise reductions at low frequencies without significantly affecting their high frequency noise reduction capabilities.
Correlates of Sex Frequency and Sexual Satisfaction Among Partnered Older Adults.
Gillespie, Brian Joseph
2017-07-04
This study examines behaviors associated with sex frequency and sexual satisfaction in a national sample of partnered older adults, age 50 to 85 (N = 9,164), together for over one year. The results indicate that older adults with active and satisfying sex lives engage more frequently in open sexual communication and setting the mood for sexual activity. Additionally, synchronicity in sexual desire and activities is related to a high-frequency and highly satisfying sex life in older adulthood. An expansive sexual repertoire, as measured by the number of sexual activities used during the last sexual encounter and the incorporation of sexual variety, is also associated with greater sex frequency and sexual satisfaction.
Code of Federal Regulations, 2014 CFR
2014-10-01
... aircraft conducting high-frequency or non-hull-mounted mid-frequency active sonar activities associated... or aircraft conducting high-frequency active sonar activities associated with anti-submarine warfare...). (2) High-frequency and non-hull mounted mid-frequency active sonar (except helicopter dipping). (3...
NASA Technical Reports Server (NTRS)
Bogdanoff, J. L.; Kayser, K.; Krieger, W.
1977-01-01
The paper describes convergence and response studies in the low frequency range of complex systems, particularly with low values of damping of different distributions, and reports on the modification of the relaxation procedure required under these conditions. A new method is presented for response estimation in complex lumped parameter linear systems under random or deterministic steady state excitation. The essence of the method is the use of relaxation procedures with a suitable error function to find the estimated response; natural frequencies and normal modes are not computed. For a 45 degree of freedom system, and two relaxation procedures, convergence studies and frequency response estimates were performed. The low frequency studies are considered in the framework of earlier studies (Kayser and Bogdanoff, 1975) involving the mid to high frequency range.
Gonzalez-Gadea, Maria Luz; Scheres, Anouk; Tobon, Carlos Andres; Damm, Juliane; Baez, Sandra; Huepe, David; Marino, Julian; Marder, Sandra; Manes, Facundo; Abrevaya, Sofia; Ibanez, Agustin
2015-01-01
Neurodevelopmental evidence suggests that children’s main decision-making strategy is to avoid options likely to induce punishment. However, the cognitive and affective factors contributing to children’s avoidance to high punishment frequency remain unknown. The present study explored psychophysiological, cognitive, and metacognitive processes associated with sensitivity to punishment frequency. We evaluated 54 participants (between 8 and 15 years old) with a modified Iowa Gambling Task for children (IGT-C) which included options with varying long-term profit and punishment frequencies. Skin conductance responses (SCRs) were recorded during this task. Additionally, we assessed IGT-C metacognitive knowledge, fluid intelligence, and executive functions. Participants exhibited behavioral avoidance and high anticipatory SCRs to options with high frequency of punishment. Moreover, age, IGT-C metacognitive knowledge, and inhibitory control were associated with individual differences in sensitivity to punishment frequency. Our results suggest that children’s preference for infrequently punished decisions is partially explained by psychophysiological signals as well as task complexity and development of cognitive control. PMID:26218584
Gonzalez-Gadea, Maria Luz; Scheres, Anouk; Tobon, Carlos Andres; Damm, Juliane; Baez, Sandra; Huepe, David; Marino, Julian; Marder, Sandra; Manes, Facundo; Abrevaya, Sofia; Ibanez, Agustin
2015-01-01
Neurodevelopmental evidence suggests that children's main decision-making strategy is to avoid options likely to induce punishment. However, the cognitive and affective factors contributing to children's avoidance to high punishment frequency remain unknown. The present study explored psychophysiological, cognitive, and metacognitive processes associated with sensitivity to punishment frequency. We evaluated 54 participants (between 8 and 15 years old) with a modified Iowa Gambling Task for children (IGT-C) which included options with varying long-term profit and punishment frequencies. Skin conductance responses (SCRs) were recorded during this task. Additionally, we assessed IGT-C metacognitive knowledge, fluid intelligence, and executive functions. Participants exhibited behavioral avoidance and high anticipatory SCRs to options with high frequency of punishment. Moreover, age, IGT-C metacognitive knowledge, and inhibitory control were associated with individual differences in sensitivity to punishment frequency. Our results suggest that children's preference for infrequently punished decisions is partially explained by psychophysiological signals as well as task complexity and development of cognitive control.
Vibration energy absorption (VEA) in human fingers-hand-arm system.
Dong, R G; Schopper, A W; McDowell, T W; Welcome, D E; Wu, J Z; Smutz, W P; Warren, C; Rakheja, S
2004-07-01
A methodology for measuring the vibration energy absorbed into the fingers and the palm exposed to vibration is proposed to study the distribution of the vibration energy absorption (VEA) in the fingers-hand-arm system and to explore its potential association with vibration-induced white finger (VWF). The study involved 12 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies in the range of 16-1000 Hz, and four different hand-handle coupling conditions (finger pull-only, hand grip-only, palm push-only, and combined grip and push). The results of the study suggest that the VEA into the fingers is considerably less than that into the palm at low frequencies (< or = 25 Hz). They are, however, comparable under the excitations in the 250-1000 Hz frequency range. The finger VEA at high frequencies (> or = 100 Hz) is practically independent of the hand-handle coupling condition. The coupling conditions affect the VEA into the fingers and the palm very differently. The finger VEA results suggest that the ISO standardized frequency weighting (ISO 5349-1, 2001) may underestimate the effect of high frequency vibration on vibration-induced finger disorders. The proposed method may provide new opportunities to examine VEA and its association with VWF and other types of vibration-induced disorders in the hand-arm system.
Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro
2017-09-01
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.
Brébion, Gildas; David, Anthony S; Bressan, Rodrigo A; Pilowsky, Lyn S
2007-01-01
The role of various types of slowing of processing speed, as well as the role of depressed mood, on each stage of verbal memory functioning in patients diagnosed with schizophrenia was investigated. Mixed lists of high- and low-frequency words were presented, and immediate and delayed free recall and recognition were required. Two levels of encoding were studied by contrasting the relatively automatic encoding of the high-frequency words and the more effortful encoding of the low-frequency words. Storage was studied by contrasting immediate and delayed recall. Retrieval was studied by contrasting free recall and recognition. Three tests of motor and cognitive processing speed were administered as well. Regression analyses involving the three processing speed measures revealed that cognitive speed was the only predictor of the recall and recognition of the low-frequency words. Furthermore, slowing in cognitive speed accounted for the deficit in recall and recognition of the low-frequency words relative to a healthy control group. Depressed mood was significantly associated with recognition of the low-frequency words. Neither processing speed nor depressed mood was associated with storage efficiency. It is concluded that both cognitive speed slowing and depressed mood impact on effortful encoding processes.
Evaluation of a multi-Kw, high frequency transformer for space applications
NASA Astrophysics Data System (ADS)
Roth, Mary Ellen
1994-08-01
Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.
Evaluation of a Multi-kw, High Frequency Transformer for Space Applications
NASA Technical Reports Server (NTRS)
Roth, Mary Ellen
1994-01-01
Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Kinshuk, E-mail: kbpchem@gmail.com
2015-05-14
In this work, we have studied the stochastic response of a single voltage-gated potassium ion channel to a periodic external voltage that keeps the system out-of-equilibrium. The system exhibits memory, resulting from time-dependent driving, that is reflected in terms of dynamic hysteresis in the current-voltage characteristics. The hysteresis loop area has a maximum at some intermediate voltage frequency and disappears in the limits of low and high frequencies. However, the (average) dissipation at long-time limit increases and finally goes to saturation with rising frequency. This raises the question: how diminishing hysteresis can be associated with growing dissipation? To answer this,more » we have studied the nonequilibrium thermodynamics of the system and analyzed different thermodynamic functions which also exhibit hysteresis. Interestingly, by applying a temporal symmetry analysis in the high-frequency limit, we have analytically shown that hysteresis in some of the periodic responses of the system does not vanish. On the contrary, the rates of free energy and internal energy change of the system as well as the rate of dissipative work done on the system show growing hysteresis with frequency. Hence, although the current-voltage hysteresis disappears in the high-frequency limit, the memory of the ion channel is manifested through its specific nonequilibrium thermodynamic responses.« less
Yokoyama, L M; Pires, L A; Ferreira, E A Gonçalves; Casarotto, R A
2015-06-01
To evaluate the effects of application of transcutaneous electrical nerve stimulation (TENS) at low and high frequencies to the abdomens of Swiss mice throughout pregnancy. Experimental animal study. Research laboratory. Thirty Swiss mice received TENS throughout pregnancy. They were divided into three groups (n=10): placebo, low-frequency TENS (LF group) and high-frequency TENS (HF group). In the placebo group, the electrodes were applied to the abdominal region without any electrical current. In the LF group, the frequency was 10 Hz, pulse duration was 200 μs and intensity started at 2 mA. In the HF group, the same parameters were applied and the frequency was 150 Hz. All stimulation protocols were applied for 20 min/day from Day 0 until Day 20. The pregnant mice were weighed on Days 0, 7, 14 and 20 to verify weekly weight gain by two-way analysis of variance. The numbers of fetuses, placentas, implantations, resorptions and major external fetal malformations on Day 20 were analysed using the Kruskal-Wallis test. No significant differences were found between the placebo and TENS groups (P>0.05). Application of low- and high-frequency TENS to the abdomens of pregnant mice did not cause any deleterious or major teratogenic effects. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Cholinergic enhancement of visual attention and neural oscillations in the human brain.
Bauer, Markus; Kluge, Christian; Bach, Dominik; Bradbury, David; Heinze, Hans Jochen; Dolan, Raymond J; Driver, Jon
2012-03-06
Cognitive processes such as visual perception and selective attention induce specific patterns of brain oscillations. The neurochemical bases of these spectral changes in neural activity are largely unknown, but neuromodulators are thought to regulate processing. The cholinergic system is linked to attentional function in vivo, whereas separate in vitro studies show that cholinergic agonists induce high-frequency oscillations in slice preparations. This has led to theoretical proposals that cholinergic enhancement of visual attention might operate via gamma oscillations in visual cortex, although low-frequency alpha/beta modulation may also play a key role. Here we used MEG to record cortical oscillations in the context of administration of a cholinergic agonist (physostigmine) during a spatial visual attention task in humans. This cholinergic agonist enhanced spatial attention effects on low-frequency alpha/beta oscillations in visual cortex, an effect correlating with a drug-induced speeding of performance. By contrast, the cholinergic agonist did not alter high-frequency gamma oscillations in visual cortex. Thus, our findings show that cholinergic neuromodulation enhances attentional selection via an impact on oscillatory synchrony in visual cortex, for low rather than high frequencies. We discuss this dissociation between high- and low-frequency oscillations in relation to proposals that lower-frequency oscillations are generated by feedback pathways within visual cortex. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cardiovascular and stress responses to short-term noise exposures-A panel study in healthy males.
Walker, Erica D; Brammer, Anthony; Cherniack, Martin G; Laden, Francine; Cavallari, Jennifer M
2016-10-01
While previous epidemiological studies report adverse effects of long-term noise exposure on cardiovascular health, the mechanisms responsible for these effects are unclear. We sought to elucidate the cardiovascular and stress response to short-term, low (31.5-125Hz) and high (500-2000Hz) frequency noise exposures. Healthy male (n=10) participants were monitored on multiple visits during no noise, low- or high-frequency noise exposure scenarios lasting 40min. Participants were fitted with an ambulatory electrocardiogram (ECG) and blood pressure measures and saliva samples were taken before, during and after noise exposures. ECGs were processed for measures of heart rate variability (HRV): high-frequency power (HF), low-frequency power (LF), the root of the mean squared difference between adjacent normal heart beats (N-N) intervals (RMSSD), and the standard deviation of N-N intervals (SDNN). Systolic blood pressure (SBP), diastolic blood pressure (DPB), and pulse were reported and saliva was analyzed for salivary cortisol and amylase. Multivariate mixed-effects linear regression models adjusted for age were used to identify statistically significant difference in outcomes by no noise, during noise or after noise exposure periods and whether this differed by noise frequency. A total of 658, 205, and 122, HRV, saliva, and blood pressure measurements were performed over 41 person days. Reductions in HRV (LF and RMSSD) were observed during noise exposure (a reduction of 19% (-35,-3.5) and 9.1% (-17,-1.1), respectively). After adjusting for noise frequency, during low frequency noise exposure, HF, LF, and SDNN were reduced (a reduction of 32% (-57,-6.2), 34% (-52,-15), and 16% (-26,-6.1), respectively) and during high frequency noise exposure, a 21% (-39,-2.3) reduction in LF, as compared to during no noise exposure, was found. No significant (p<0.05) changes in blood pressure, salivary cortisol, or amylase were observed. These results suggest that exposure to noise, and in particular, to low-frequency noise, negatively impacts HRV. The frequencies of noise should be considered when evaluating the cardiovascular health impacts of exposure. Copyright © 2016 Elsevier Inc. All rights reserved.
Cardiovascular and Stress Responses to Short-Term Noise Exposures—A Panel Study in Healthy Males
Walker, Erica D; Brammer, Anthony; Cherniack, Martin G; Laden, Francine; Cavallari, Jennifer M
2016-01-01
Background While previous epidemiological studies report adverse effects of long-term noise exposure on cardiovascular health, the mechanisms responsible for these effects are unclear. We sought to elucidate the cardiovascular and stress response to short-term, low (31.5-125 Hz) and high (500 – 2000 Hz) frequency noise exposures. Methods Healthy male (n = 10) participants were monitored on multiple visits during no noise, low- or high-frequency noise exposure scenarios lasting 40 minutes. Participants were fitted with an ambulatory electrocardiogram (ECG) and blood pressure measures and saliva samples were taken before, during and after noise exposures. ECGs were processed for measures of heart rate variability (HRV): high-frequency power (HF), low-frequency power (LF), the root of the mean squared difference between adjacent normal heart beats (N-N) intervals (RMSSD), and the standard deviation of N-N intervals (SDNN). Systolic blood pressure (SBP), diastolic blood pressure (DPB), and pulse were reported and saliva was analyzed for salivary cortisol and amylase. Multivariate mixed-effects linear regression models adjusted for age were used to identify statistically significant difference in outcomes by no noise, during noise or after noise exposure periods and whether this differed by noise frequency. Results A total of 658, 205, and 122, HRV, saliva,and blood pressure measurements were performed over 41 person days. Reductions in HRV (LF and RMSSD) were observed during noise exposure (a reduction of 19%(−35,−3.5) and 9.1%(−17,−1.1), respectively). After adjusting for noise frequency, during low frequency noise exposure, HF, LF, and SDNN were reduced (a reduction of 32%(−57,−6.2), 34%(−52,−15), and 16%(−26,−6.1), respectively and during high frequency noise exposure, a 21%(−39,−2.3) reduction in LF, as compared to during no noise exposure was found. No significant (p>0.05) changes in blood pressure,salivary cortisol or amylase were observed. Conclusions These results suggest that exposure to noise, and in particular, to low-frequency noise negatively impacts HRV. The frequencies of noise should be considered when evaluating the cardiovascular health impacts of exposure. PMID:27371930
ERIC Educational Resources Information Center
Semmel, Melvyn I.; And Others
To explore the binaural integration abilities of six educable mentally retarded boys (ages 8 to 13) and six normal boys (ages 7 to 12) to detect possible brain inju"y, an adaptation of Matzker's (1958) technique involving separating words into high and low frequencies was used. One frequency filter system presented frequencies from 425 to 1275…
David, Hamilton P; Carey, Cayelan C.; Arvola, Lauri; Arzberger, Peter; Brewer, Carol A.; Cole, Jon J; Gaiser, Evelyn; Hanson, Paul C.; Ibelings, Bas W; Jennings, Eleanor; Kratz, Tim K; Lin, Fang-Pang; McBride, Christopher G.; de Motta Marques, David; Muraoka, Kohji; Nishri, Ami; Qin, Boqiang; Read, Jordan S.; Rose, Kevin C.; Ryder, Elizabeth; Weathers, Kathleen C.; Zhu, Guangwei; Trolle, Dennis; Brookes, Justin D
2014-01-01
A Global Lake Ecological Observatory Network (GLEON; www.gleon.org) has formed to provide a coordinated response to the need for scientific understanding of lake processes, utilising technological advances available from autonomous sensors. The organisation embraces a grassroots approach to engage researchers from varying disciplines, sites spanning geographic and ecological gradients, and novel sensor and cyberinfrastructure to synthesise high-frequency lake data at scales ranging from local to global. The high-frequency data provide a platform to rigorously validate process- based ecological models because model simulation time steps are better aligned with sensor measurements than with lower-frequency, manual samples. Two case studies from Trout Bog, Wisconsin, USA, and Lake Rotoehu, North Island, New Zealand, are presented to demonstrate that in the past, ecological model outputs (e.g., temperature, chlorophyll) have been relatively poorly validated based on a limited number of directly comparable measurements, both in time and space. The case studies demonstrate some of the difficulties of mapping sensor measurements directly to model state variable outputs as well as the opportunities to use deviations between sensor measurements and model simulations to better inform process understanding. Well-validated ecological models provide a mechanism to extrapolate high-frequency sensor data in space and time, thereby potentially creating a fully 3-dimensional simulation of key variables of interest.
Clendenen, Tess V; Rendleman, Justin; Ge, Wenzhen; Koenig, Karen L; Wirgin, Isaac; Currie, Diane; Shore, Roy E; Kirchhoff, Tomas; Zeleniuch-Jacquotte, Anne
2015-01-01
Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA. We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs) using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison. We observed that 60 of the 81 SNPs (74%) had high call frequencies (≥95%) using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95%) had highly concordant (>98%) genotype calls across all three sample types. High purity was not a critical factor to successful genotyping. Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.
Association of autonomic nervous system and EEG scalp potential during playing 2D Grand Turismo 5.
Subhani, Ahmad Rauf; Likun, Xia; Saeed Malik, Aamir
2012-01-01
Cerebral activation and autonomic nervous system have importance in studies such as mental stress. The aim of this study is to analyze variations in EEG scalp potential which may influence autonomic activation of heart while playing video games. Ten healthy participants were recruited in this study. Electroencephalogram (EEG) and electrocardiogram (ECG) signals were measured simultaneously during playing video game and rest conditions. Sympathetic and parasympathetic innervations of heart were evaluated from heart rate variability (HRV), derived from the ECG. Scalp potential was measured by the EEG. The results showed a significant upsurge in the value theta Fz/alpha Pz (p<0.001) while playing game. The results also showed tachycardia while playing video game as compared to rest condition (p<0.005). Normalized low frequency power and ratio of low frequency/high frequency power were significantly increased while playing video game and normalized high frequency power sank during video games. Results showed synchronized activity of cerebellum and sympathetic and parasympathetic innervation of heart.
ERIC Educational Resources Information Center
Cho, Euna
2017-01-01
The present study examined the effects of multimedia enhancement in video form in addition to textual information on L2 vocabulary instruction for high-level, low-frequency English words among Korean learners of English. Although input-based incidental learning of L2 vocabulary through extensive reading has been conventionally believed to be…
High-frequency and hot-platen curing of medium-density fiberboards
R.R. Stevens; G.E. Woodson
1977-01-01
The effects of two curing methods- high-frequency heating and hot-platen heating- on the properties of a ure-formaldehyd-bonded medium-density fiberboard prepared with a southern-hardwoods furnish (50% southern red oak, 25% mockernut hickory, and 25% sweetgum) were studied. Boards of three densities- 38, 44, and 50 lb./ft.3- were cured by the two...
The arsenic removal from arsenopyrite in sulfide mineral by physicochemical extraction
NASA Astrophysics Data System (ADS)
Jo, Jiyu; Cho, Kanghee; Choi, Nagchoul; Park*, Cheonyoung
2015-04-01
The most abundant As ore mineral is arsenopyrite (FeAsS). Arsenopyrite is present in sulfide ores associated with sediment-hosted Au deposits, it tends to be the earliest-formed mineral, derived from hydrothermal solutions and formed at temperatures typically of 100(degree Celsius) or more. The aim of this study was to investigate the mineralogical phase change and arsenic removal from arsenopyrite as a penalty element in sulfide mineral contained Au by physical extraction (high frequency) and chemical leaching (thiocyanate). Arsenic removal experiments for were performed under various conditions of high frequency exposure(1~35 min), thiocyanate concentration (0.1~1.0M), HCl concentration (0.1~2.0M), copper(2) sulfate concentration (0.1~1.0M), temperature (30~60 degree Celsius). Increasing the high frequency exposure produced a positive effect on arsenic removal in arsenopyrite. The highest percentage arsenic removal of 96.67% was obtained under the following conditions by thiocyanate leaching: thiocyanate concentration = 1.0M ; HCl concentration = 2.0M ; copper(2) sulfate concentration = 1.0M ; temperature = 60(degree Celsius) This study demonstrates the adequate performance of physical extraction (high frequency) and chemical leaching (thiocyanate) for the arsenic removal from arsenopyrite as a penalty element.
Pitel, Ira J.
1987-02-03
The present invention provides an electrical power inverter method and apparatus, which includes a high frequency link, for converting DC power into AC power. Generally stated, the apparatus includes a first high frequency module which produces an AC voltage at a first output frequency, and a second high frequency inverter module which produces an AC voltage at a second output frequency that is substantially the same as the first output frequency. The second AC voltage is out of phase with the first AC voltage by a selected angular phase displacement. A mixer mixes the first and second output voltages to produce a high frequency carrier which has a selected base frequency impressed on the sidebands thereof. A rectifier rectifies the carrier, and a filter filters the rectified carrier. An output inverter inverts the filtered carrier to produce an AC line voltage at the selected base frequency. A phase modulator adjusts the relative angular phase displacement between the outputs of the first and second high frequency modules to control the base frequency and magnitude of the AC line voltage.
Pitel, I.J.
1987-02-03
The present invention provides an electrical power inverter method and apparatus, which includes a high frequency link, for converting DC power into AC power. Generally stated, the apparatus includes a first high frequency module which produces an AC voltage at a first output frequency, and a second high frequency inverter module which produces an AC voltage at a second output frequency that is substantially the same as the first output frequency. The second AC voltage is out of phase with the first AC voltage by a selected angular phase displacement. A mixer mixes the first and second output voltages to produce a high frequency carrier which has a selected base frequency impressed on the sidebands thereof. A rectifier rectifies the carrier, and a filter filters the rectified carrier. An output inverter inverts the filtered carrier to produce an AC line voltage at the selected base frequency. A phase modulator adjusts the relative angular phase displacement between the outputs of the first and second high frequency modules to control the base frequency and magnitude of the AC line voltage. 19 figs.
Toledano, Mireille B; Auvinen, Anssi; Tettamanti, Giorgio; Cao, Yang; Feychting, Maria; Ahlbom, Anders; Fremling, Karin; Heinävaara, Sirpa; Kojo, Katja; Knowles, Gemma; Smith, Rachel B; Schüz, Joachim; Johansen, Christoffer; Poulsen, Aslak Harbo; Deltour, Isabelle; Vermeulen, Roel; Kromhout, Hans; Elliott, Paul; Hillert, Lena
2018-01-01
This study investigates validity of self-reported mobile phone use in a subset of 75 993 adults from the COSMOS cohort study. Agreement between self-reported and operator-derived mobile call frequency and duration for a 3-month period was assessed using Cohen's weighted Kappa (κ). Sensitivity and specificity of both self-reported high (≥10 calls/day or ≥4h/week) and low (≤6 calls/week or <30min/week) mobile phone use were calculated, as compared to operator data. For users of one mobile phone, agreement was fair for call frequency (κ=0.35, 95% CI: 0.35, 0.36) and moderate for call duration (κ=0.50, 95% CI: 0.49, 0.50). Self-reported low call frequency and duration demonstrated high sensitivity (87% and 76% respectively), but for high call frequency and duration sensitivity was lower (38% and 56% respectively), reflecting a tendency for greater underestimation than overestimation. Validity of self-reported mobile phone use was lower in women, younger age groups and those reporting symptoms during/shortly after using a mobile phone. This study highlights the ongoing value of using self-report data to measure mobile phone use. Furthermore, compared to continuous scale estimates used by previous studies, categorical response options used in COSMOS appear to improve validity considerably, most likely by preventing unrealistically high estimates from being reported. Copyright © 2017 Elsevier GmbH. All rights reserved.
Frequency dependent Lg attenuation in south-central Alaska
McNamara, D.E.
2000-01-01
The characteristics of seismic energy attenuation are determined using high frequency Lg waves from 27 crustal earthquakes, in south-central Alaska. Lg time-domain amplitudes are measured in five pass-bands and inverted to determine a frequency-dependent quality factor, Q(f), model for south-central Alaska. The inversion in this study yields the frequency-dependent quality factor, in the form of a power law: Q(f) = Q0fη = 220(±30) f0.66(±0.09) (0.75≤f≤12Hz). The results from this study are remarkably consistent with frequency dependent quality factor estimates, using local S-wave coda, in south-central Alaska. The consistency between S-coda Q(f) and Lg Q(f) enables constraints to be placed on the mechanism of crustal attenuation in south-central Alaska. For the range of frequencies considered in this study both scattering and intrinsic attenuation mechanisms likely play an equal role.
The Cerebellar Mossy Fiber Synapse as a Model for High-Frequency Transmission in the Mammalian CNS.
Delvendahl, Igor; Hallermann, Stefan
2016-11-01
The speed of neuronal information processing depends on neuronal firing frequency. Here, we describe the evolutionary advantages and ubiquitous occurrence of high-frequency firing within the mammalian nervous system in general. The highest firing frequencies so far have been observed at the cerebellar mossy fiber to granule cell synapse. The mechanisms enabling high-frequency transmission at this synapse are reviewed and compared with other synapses. Finally, information coding of high-frequency signals at the mossy fiber synapse is discussed. The exceptionally high firing frequencies and amenability to high-resolution technical approaches both in vitro and in vivo establish the cerebellar mossy fiber synapse as an attractive model to investigate high-frequency signaling from the molecular up to the network level. Copyright © 2016 Elsevier Ltd. All rights reserved.
Microwave dynamics of high aspect ratio superconducting nanowires studied using self-resonance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santavicca, Daniel F., E-mail: daniel.santavicca@unf.edu; Adams, Jesse K.; Grant, Lierd E.
2016-06-21
We study the microwave impedance of extremely high aspect ratio (length/width ≈ 5000) superconducting niobium nitride nanowires. The nanowires are fabricated in a compact meander geometry that is in series with the center conductor of a 50 Ω coplanar waveguide transmission line. The transmission coefficient of the sample is measured up to 20 GHz. At high frequency, a peak in the transmission coefficient is seen. Numerical simulations show that this is a half-wave resonance along the length of the nanowire, where the nanowire acts as a high impedance, slow wave transmission line. This resonance sets the upper frequency limit for these nanowires asmore » inductive elements. Fitting simulations to the measured resonance enables a precise determination of the nanowire's complex sheet impedance at the resonance frequency. The real part is a measure of dissipation, while the imaginary part is dominated by kinetic inductance. We characterize the dependence of the sheet resistance and sheet inductance on both temperature and current and compare the results to recent theoretical predictions for disordered superconductors. These results can aid in the understanding of high frequency devices based on superconducting nanowires. They may also lead to the development of novel superconducting devices such as ultra-compact resonators and slow-wave structures.« less
NASA Astrophysics Data System (ADS)
Wiercigroch, M.; Bhattacharya, J.
2017-12-01
The Earth is considered to have been in a "greenhouse state" during the Cretaceous Period. High-frequency sedimentary cycles are observed throughout the Cretaceous section of the Western Interior Seaway. Even though this warm Cretaceous climate suggests an ice-free planet Earth, there has been much debate as to whether the observed high-frequency sedimentary cycles are climate-driven Milankovitch-scale cycles that would suggest glaciers during the Cretaceous Period. This study tests the hypothesis of a glacio-eustatic origin of high-frequency cyclicity in the Turonian Juana Lopez Member of the Mancos Shale in the San Juan Basin, New Mexico. Data for this study was obtained from two stratigraphic measured sections which are 3.2 km apart, and located southwest of Shiprock. The two sections are found approximately 60 km away from the Turonian shoreline in an offshore marine environment. A high-resolution thin bed facies analysis on both sections reveals the Juana Lopez to be deposited in a fluvial-dominated, mixed wave- and fluvial-influenced environment. The Juana Lopez is shown to be an overall coarsening-upward sequence, displaying a shallowing regressive environment. Correlations between the two sections reveal 13 correlated parasequences identified through the violation of Walther's Law. An average cyclicity frequency of ca 90 kyr was determined for the sequences by bracketing the Inocermus dimidus and Scaphites whitfieldi biostratigraphic zones within the Juana Lopez sections. This cyclicity represents short eccentricity Milankovitch cycles. Many studies have confirmed that the observed Milankovitch-scaled cyclicity in the Cretaceous must be controlled by glacio-eustasy. With similar Milankovitch cyclicity found in the Juana Lopez, the short eccentricity Milankovitch cycles are interpreted as being glacio-eustatic in origin, which supports the presence of ice in the Cretaceous Period.
The relationship between food frequency and menstrual distress in high school females
Mohamadirizi, Soheila; Kordi, Masoumeh
2015-01-01
Background: Nutrition pattern is one of the important factors predicting menstrual distress, which varies among different cultures and countries. The purpose of this study is to determine the relationship between food frequency and menstrual distress in high school girls from Mashhad. Materials and Methods: This cross-sectional study was conducted in 2012 using a two-stage sampling method on 407 high school female students from Mashhad who met the inclusion criteria. Subjects completed questionnaires of demographic characteristics, food frequency, and Menstrual Distress Questionnaire (MDQ) during three phases of the menstrual cycle (a week before bleeding, during menstrual bleeding period, and a week after menstruation). The collected data were analyzed by statistical tests such as Pearson correlation coefficient test, independent Student's t-test, and one-way analysis of variance (ANOVA). Results: Results showed that 87.7% of the students were at moderate economic status, 82.2% were exposed to cigarette smoke, 94.8% had mothers without university education, and 9.4% had working mothers. About 71% of the students reported minor pre-menstruation distress, 81% reported minor distress during bleeding, and 39% reported minor post-menstruation distress. In addition, the mean (SD) values for sweet–fatty foods, salty–fatty foods, fast foods, and caffeine were 3.6, 3.3, 1.3, and 10.2 per week, respectively. In addition, Pearson correlation coefficient test showed no significant correlation between total menstruation distress and food frequency (P > 0.05). Conclusions: With regard to the inappropriate food frequency and high intensity of menstrual distress among high school students and as health care and educational efforts for prevention and health promotion in society are among the duties of health workers, the results of this study can help the officials involved in education to emphasize on nutrition and the menstrual health of students. PMID:26793254
NASA Astrophysics Data System (ADS)
Li, H.; Plink-Bjorklund, P.
2017-12-01
Studies (e.g., Jerolmack and Paola, 2010) have suggested that autogenic processes act as a filter for high-frequency environmental signals, and the underlying assumption is that autogenic processes can cause fluctuations in sediment and water discharge that modify or shred the signal. This assumption, however, fails to recognize that autogenic processes and their final products are dynamic and that they can respond to allogenic forcings. We compile a database containing published field studies, physical experiments, and numerical modeling works, and analyze the data under different boundary conditions. Our analyses suggest different conclusions. Autogenic processes are intrinsic to the sedimentary system, and they possess distinct patterns under steady boundary conditions. Upon changing boundary conditions, the autogenic patterns are also likely to change (depending on the magnitude of the change in the boundary conditions). Therefore, the pattern change provides us with the opportunity to restore the high-frequency signals that may not pass through the transfer zone. Here we present the theoretical basis for using autogenic deposits to infer high-frequency signals as well as modern and ancient field examples, physical experiments, and modeling works to illustrate the autogenic response to allogenic forcings. The field studies show the potential of using autogenic deposits to restore short-term climatic variability. The experiments demonstrate that autogenic processes in rivers are closely linked to sediment and water discharge. The modeling examples reveal the counteracting effects of some autogenic processes to form a self-organized pattern under a set of specific boundary conditions. We also highlight the limitations and challenges that need more research efforts to restore high-frequency signals. Some critical issues include the magnitude of the signals, the effect of the interference between different signals, and the incompleteness of the autogenic deposits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Yu Mao, E-mail: yumaowu@fudan.edu.cn; Teng, Si Jia, E-mail: sjteng12@fudan.edu.cn
In this work, we develop the numerical steepest descent path (NSDP) method to calculate the physical optics (PO) radiations with the quadratic concave phase variations. With the surface integral equation method, the physical optics (PO) scattered fields are formulated and further reduced to the surface integrals. The high frequency physical critical points contributions, including the stationary phase points, the boundary resonance points and the vertex points are comprehensively studied via the proposed NSDP method. The key contributions of this work are twofold. One is that together with the PO integrals taking the quadratic parabolic and hyperbolic phase terms, this workmore » makes the NSDP theory be complete for treating the PO integrals with quadratic phase variations. Another is that, in order to illustrate the transition effect of the high frequency physical critical points, in this work, we consider and further extend the NSDP method to calculate the PO integrals with the coalescence of the high frequency critical points. Numerical results for the highly oscillatory PO integral with the coalescence of the critical points are given to verify the efficiency of the proposed NSDP method. The NSDP method could achieve the frequency independent computational workload and error controllable accuracy in all the numerical experiments, especially for the case of the coalescence of the high frequency critical points.« less
Music students: conventional hearing thresholds and at high frequencies.
Lüders, Débora; Gonçalves, Cláudia Giglio de Oliveira; Lacerda, Adriana Bender de Moreira; Ribas, Ângela; Conto, Juliana de
2014-01-01
Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. Study design was a retrospective observational cohort. Conventional and high-frequency audiometry was performed in 42 music students (Madsen Itera II audiometer and TDH39P headphones for conventional audiometry, and HDA 200 headphones for high-frequency audiometry). Of the 42 students, 38.1% were female students and 61.9% were male students, with a mean age of 26 years. At conventional audiometry, 92.85% had hearing thresholds within normal limits; but even within the normal limits, the worst results were observed in the left ear for all frequencies, except for 4000 Hz; compared to the non-musician group, the worst results occurred at 500 Hz in the left ear, and at 250 Hz, 6000 Hz, 9000 Hz, 10,000 Hz, and 11,200 Hz in both the ears. The periodic evaluation of high-frequency thresholds may be useful in the early detection of hearing loss in musicians. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Os incae: variation in frequency in major human population groups
HANIHARA, TSUNEHIKO; ISHIDA, HAJIME
2001-01-01
The variation in frequency of the Inca bone was examined in major human populations around the world. The New World populations have generally high frequencies of the Inca bone, whereas lower frequencies occur in northeast Asians and Australians. Tibetan/Nepalese and Assam/Sikkim populations in northeast India have more Inca bones than do neighbouring populations. Among modern populations originally derived from eastern Asian population stock, the frequencies are highest in some of the marginal isolated groups. In Central and West Asia as well as in Europe, frequency of the Inca bone is relatively low. The incidence of the complete Inca bone is, moreover, very low in the western hemisphere of the Old World except for Subsaharan Africa. Subsaharan Africans show as a whole a second peak in the occurrence of the Inca bone. Geographical and ethnographical patterns of the frequency variation of the Inca bone found in this study indicate that the possible genetic background for the occurrence of this bone cannot be completely excluded. Relatively high frequencies of the Inca bone in Subsaharan Africans indicate that this trait is not a uniquely eastern Asian regional character. PMID:11273039
Sun, Chao; Pye, Stephen D.; Browne, Jacinta E.; Janeczko, Anna; Ellis, Bill; Butler, Mairead B.; Sboros, Vassilis; Thomson, Adrian J.W.; Brewin, Mark P.; Earnshaw, Charles H.; Moran, Carmel M.
2012-01-01
This study characterized the acoustic properties of an International Electromechanical Commission (IEC) agar-based tissue mimicking material (TMM) at ultrasound frequencies in the range 10–47 MHz. A broadband reflection substitution technique was employed using two independent systems at 21°C ± 1°C. Using a commercially available preclinical ultrasound scanner and a scanning acoustic macroscope, the measured speeds of sound were 1547.4 ± 1.4 m∙s−1 and 1548.0 ± 6.1 m∙s−1, respectively, and were approximately constant over the frequency range. The measured attenuation (dB∙cm−1) was found to vary with frequency f (MHz) as 0.40f + 0.0076f2. Using this polynomial equation and extrapolating to lower frequencies give values comparable to those published at lower frequencies and can estimate the attenuation of this TMM in the frequency range up to 47 MHz. This characterisation enhances understanding in the use of this TMM as a tissue equivalent material for high frequency ultrasound applications. PMID:22502881
Interpersonal interactions, job demands and work-related outcomes in pharmacy.
Gaither, Caroline A; Nadkarni, Anagha
2012-04-01
Objectives The objective of this study was to examine the interaction between job demands of pharmacists and resources in the form of interpersonal interactions and its association with work-related outcomes such as organizational and professional commitment, job burnout, professional identity and job satisfaction. The job demands-resources (JD-R) model served as the theoretical framework. Methods Subjects for the study were drawn from the Pharmacy Manpower Project Database (n = 1874). A 14-page mail-in survey measured hospital pharmacists' responses on the frequency of occurrence of various job-related scenarios as well as work-related outcomes. The study design was a 2 × 2 factorial design. Responses were collected on a Likert scale. Descriptive statistics, reliability analyses and correlational and multiple regression analyses were conducted using SPSS version 17 (SPSS, Chicago, IL, USA). Key findings The 566 pharmacists (30% response rate) who responded to the survey indicated that high-demand/pleasant encounters and low-demand/pleasant encounters occurred more frequently in the workplace. The strongest correlations were found between high-demand/unpleasant encounters and frequency and intensity of emotional exhaustion. Multiple regression analyses indicated that when controlling for demographic factors high-demand/unpleasant encounters were negatively related to affective organizational commitment and positively related to frequency and intensity of emotional exhaustion. Low-demand/pleasant encounters were positively related to frequency and intensity of personal accomplishment. Low-demand/unpleasant encounters were significantly and negatively related to professional commitment, job satisfaction and frequency and intensity of emotional exhaustion, while high-demand/pleasant encounters were also related to frequency and intensity of emotional exhaustion Conclusion Support was found for the JD-R model and the proposed interaction effects. Study results suggest that adequate attention must be paid to the interplay between demands on the job and interactions with healthcare professionals to improve the quality of the pharmacist's work life. Future research should examine other types of job demands and resources. © 2011 The Authors. IJPP © 2011 Royal Pharmaceutical Society.
Nasal high-frequency oscillatory ventilation impairs heated humidification: A neonatal bench study.
Ullrich, Tim L; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik S
2017-11-01
Nasal high-frequency oscillatory ventilation (nHFOV) is a novel mode of non-invasive ventilation used in neonates. However, upper airway obstructions due to viscous secretions have been described as specific adverse effects. We hypothesized that high-frequency oscillations reduce air humidity in the oropharynx, resulting in upper airway desiccation. Therefore, we aimed to investigate the effects of nHFOV ventilatory settings on oropharyngeal gas conditions. NHFOV or nasal continuous positive airway pressure (nCPAP) was applied, along with heated humidification, to a previously established neonatal bench model that simulates oropharyngeal gas conditions during spontaneous breathing through an open mouth. A digital thermo-hygro sensor measured oropharyngeal temperature (T) and humidity at various nHFOV frequencies (7, 10, 13 Hz), amplitudes (10, 20, 30 cmH 2 O), and inspiratory-to-expiratory (I:E) ratios (25:75, 33:66, 50:50), and also during nCPAP. Relative humidity was always >99%, but nHFOV resulted in lower mean T and absolute humidity (AH) in comparison to nCPAP (P < 0.001). Specifically, decreasing the nHFOV frequency and increasing nHFOV amplitude caused a decline in T and AH (P < 0.001). Mean T and AH were highest during nCPAP (T 34.8 ± 0.6°C, AH 39.3 ± 1.3 g · m -3 ) and lowest during nHFOV at a frequency of 7 Hz and an amplitude of 30 cmH 2 O (T 32.4 ± 0.3°C, AH 34.7 ± 0.5 g · m -3 ). Increasing the I:E ratio also reduced T and AH (P = 0.03). Intensified nHFOV settings with low frequencies, high amplitudes, and high I:E ratios may place infants at an increased risk of upper airway desiccation. Future studies should investigate strategies to optimize heated humidification during nHFOV. © 2017 Wiley Periodicals, Inc.
Rosselló, J M; Dellavale, D; Bonetto, F J
2016-07-01
The use of bi-frequency driving in sonoluminescence has proved to be an effective way to avoid the spatial instability (pseudo-orbits) developed by bubbles in systems with high viscous liquids like sulfuric or phosphoric acids. In this work, we present extensive experimental and numerical evidence in order to assess the effect of the high frequency component (PAc(HF)) of a bi-harmonic acoustic pressure field on the dynamic of sonoluminescent bubbles in an aqueous solution of sulfuric acid. The present study is mainly focused on the role of the harmonic frequency (Nf0) and the relative phase between the two frequency components (φb) of the acoustic field on the spatial, positional and diffusive stability of the bubbles. The results presented in this work were analyzed by means of three different approaches. First, we discussed some qualitative considerations about the changes observed in the radial dynamics, and the stability of similar bubbles under distinct bi-harmonic drivings. Later, we have investigated, through a series of numerical simulations, how the use of high frequency harmonic components of different order N, affects the positional stability of the SL bubbles. Furthermore, the influence of φb in their radius temporal evolution is systematically explored for harmonics ranging from the second to the fifteenth harmonic (N=2-15). Finally, a multivariate analysis based on the covariance method is performed to study the dependences among the parameters characterizing the SL bubble. Both experimental and numerical results indicate that the impact of PAc(HF) on the positional instability and the radial dynamics turns to be progressively negligible as the order of the high frequency harmonic component grows (i.e. N ≫ 1), however its effectiveness on the reduction of the spatial instability remains unaltered or even improved. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of processing parameters in the sonic assisted water extraction (SAWE) of 6-gingerol.
Syed Jaapar, Syaripah Zaimah; Morad, Noor Azian; Iwai, Yoshio; Nordin, Mariam Firdhaus Mad
2017-09-01
The use of water in subcritical conditions for extraction has several drawbacks. These include the safety features, higher production costs and possible degradation of the bioactive compounds. To overcome these problems, sonic energy and an entrainer were used as external interventions to decrease the polarity of water at milder operating conditions. The effect of low (28kHz) and high (800kHz) frequencies of sonication in the extraction of the main ginger bioactive compound (6-gingerol) were compared. Six parameters were studied: mean particle size (MPS, mm), time of extraction, applied power, sample to solvent ratio (w/v), temperature of extraction, and the percentage of entrainer. The optimum conditions for high frequency SAWE prototype were MPS 0.89-1.77mm, 45min, 40W applied power, 1:30 (w/v), 45°C, and 15% of ethanol as entrainer. Two-way analysis of variance (ANOVA) gave the most significant parameter, which was power with F (1, 45.07), p<2.50×10 -9 . Although the effect of low frequency was stronger than high frequency, at the optimum conditions of the sample to solvent ratio 1:30 (w/v) with 700mL solvent and temperature 45°C, the concentration and recovery of 6-gingerol from high frequency of SAWE prototype was 2.69 times higher than at low frequency of SAWE. It was found that although the effects of high frequency (800kHz) were negligible in other studies, it could extract suitable compounds, such as 6-gingerol, at lower temperature. Therefore, the effects of sonication, which cause an enlargement in the cell wall of the ginger plant matrix, were observed using a Scanning Electron Microscope (SEM). It was found that the applied power of sonication was the most significant parameter compared to the other parameters. Copyright © 2017 Elsevier B.V. All rights reserved.
So, Rosa Q; McConnell, George C; Grill, Warren M
2017-03-01
Methamphetamine-induced circling is used to quantify the behavioral effects of subthalamic nucleus (STN) deep brain stimulation (DBS) in hemiparkinsonian rats. We observed a frequency-dependent transient effect of DBS on circling, and quantified this effect to determine its neuronal basis. High frequency STN DBS (75-260Hz) resulted in transient circling contralateral to the lesion at the onset of stimulation, which was not sustained after the first several seconds of stimulation. Following the transient behavioral change, DBS resulted in a frequency-dependent steady-state reduction in pathological ipsilateral circling, but no change in overall movement. Recordings from single neurons in globus pallidus externa (GPe) and substantia nigra pars reticulata (SNr) revealed that high frequency, but not low frequency, STN DBS elicited transient changes in both firing rate and neuronal oscillatory power at the stimulation frequency in a subpopulation of GPe and SNr neurons. These transient changes were not sustained, and most neurons exhibited a different response during the steady-state phase of DBS. During the steady-state, DBS produced elevated neuronal oscillatory power at the stimulus frequency in a majority of GPe and SNr neurons, and the increase was more pronounced during high frequency DBS than during low frequency DBS. Changes in oscillatory power during both transient and steady-state DBS were highly correlated with changes in firing rates. These results suggest that distinct neural mechanisms were responsible for transient and sustained behavioral responses to STN DBS. The transient contralateral turning behavior following the onset of high frequency DBS was paralleled by transient changes in firing rate and oscillatory power in the GPe and SNr, while steady-state suppression of ipsilateral turning was paralleled by sustained increased synchronization of basal ganglia neurons to the stimulus pulses. Our analysis of distinct frequency-dependent transient and steady-state responses to DBS lays the foundation for future mechanistic studies of the immediate and persistent effects of DBS. Copyright © 2016 Elsevier B.V. All rights reserved.
Dielectric studies on PVA/PVP blend polymer electrolyte films
NASA Astrophysics Data System (ADS)
Kumar, B. Ranjit; Basha, S. K. Shahenoor; Rao, M. C.
2018-05-01
Biodegradable blend polymer electrolytes of PVA/PVP with different wt% ratios of MgCl2.6H2O have been prepared using solution cast technique. Dielectric studies were performed on to the prepared films using HIOKI 3532-50 in the frequency range 5000 Hz - 50000 KHz. As increasing the frequency the dielectric constant gradually decreases and found to be high for the sample prepared at 30 wt%; this concludes that the drifting of ions is high giving raise to conductivity phenomenon.
BCI demographics II: how many (and what kinds of) people can use a high-frequency SSVEP BCI?
Volosyak, Ivan; Valbuena, Diana; Lüth, Thorsten; Malechka, Tatsiana; Gräser, Axel
2011-06-01
Brain-computer interface (BCI) systems use brain activity as an input signal and enable communication without movement. This study is a successor of our previous study (BCI demographics I) and examines correlations among BCI performance, personal preferences, and different subject factors such as age or gender for two sets of steady-state visual evoked potential (SSVEP) stimuli: one in the medium frequency range (13, 14, 15 and 16 Hz) and another in the high-frequency range (34, 36, 38, 40 Hz). High-frequency SSVEPs (above 30 Hz) diminish user fatigue and risk of photosensitive epileptic seizures. Results showed that most people, despite having no prior BCI experience, could use the SSVEP-based Bremen-BCI system in a very noisy field setting at a fair. Results showed that demographic parameters as well as handedness, tiredness, alcohol and caffeine consumption, etc., have no significant effect on the performance of SSVEP-based BCI. Most subjects did not consider the flickering stimuli annoying, only five out of total 86 participants indicated change in fatigue during the experiment. 84 subjects performed with a mean information transfer rate of 17.24 ±6.99 bit/min and an accuracy of 92.26 ±7.82% with the medium frequency set, whereas only 56 subjects performed with a mean information transfer rate of 12.10 ±7.31 bit/min and accuracy of 89.16 ±9.29% with the high-frequency set. These and other demographic analyses may help identify the best BCI for each user.
NASA Astrophysics Data System (ADS)
Chen, Y.; Han, D.
2017-12-01
Water system is an essential component in a smart city for its sustainability and resilience. The freshness and beauty of the water body would please people as well as benefit the local aquatic ecosystems. Water quality monitoring approach has evolved from the manual lab-based monitoring approach to the manual in-situ monitoring approach, and finally to the latest wireless-sensor-network (WSN) based solutions in recent decades. The development of the in-situ water quality sensors enable humans to collect high-frequency and real-time water quality data. This poster aims to explore the advantages of the high-frequency water quality data over the low-frequency data collected manually. The data is collected by a remote real-time high-frequency water quality monitor system based on the cutting edge smart city infrastructure in Bristol - `Bristol Is Open'. The water quality of Bristol Floating Harbour is monitored which is the focal area of Bristol with new buildings and features redeveloped in the past decades. This poster will first briefly introduce the water quality monitoring system, followed by the analysis of the advantages of the sub-hourly water quality data. Thus, the suggestion on the monitoring frequency will be given.
Kanto, Kousei; Ito, Hiroyuki; Noso, Shinsuke; Babaya, Naru; Hiromine, Yoshihisa; Taketomo, Yasunori; Toma, Junko; Niwano, Fumimaru; Yasutake, Sara; Kawabata, Yumiko; Ikegami, Hiroshi
2017-09-30
Differences in the efficacy and safety of antidiabetic drugs among different ethnic groups are well documented. Metformin is widely used in the treatment of type 2 diabetes in Western countries, but high doses of metformin have been approved only recently for clinical use in Japan. The aim of the present study was to investigate the effects of dosage and dosing frequency on the efficacy and safety of high-dose metformin in Japanese patients. A total of 71 Japanese patients with type 2 diabetes were prospectively studied for the effects of dosage and dosing frequency on the efficacy and safety of metformin during hospitalization. Dose effects were studied in 27 patients treated with 0, 500, 1,000, 1,500 and 2,250 mg/day of metformin. The effect of dosing frequency was compared in 56 patients with 1,500 mg/day of metformin administered either two or three times per day. Significant dose-dependent improvement in daily profiles of blood glucose was observed with metformin dosages up to 1,500 mg/day, with a trend towards further improvement observed at 2,250 mg/day. The efficacy of 1,500 mg of metformin was comparable when the drug was administered either two or three times per day. The most frequently reported side-effects were gastrointestinal symptoms, which were not affected by the dosage or dosing frequency of metformin. These results show that the efficacy of high-dose metformin is dose-dependent in Japanese patients. The efficacy and safety of metformin were similar when the drug was administered either two or three times per day. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Krietemeyer, Andreas; ten Veldhuis, Marie-claire; van de Giesen, Nick
2017-04-01
Recent research has shown that assimilation of Precipitable Water Vapor (PWV) measurements into numerical weather predictions models improve the quality of rainfall now- and forecasting. Local PWV fluctuations may be related with water vapor increases in the lower troposphere which lead to deep convection. Prior studies show that about 20 minutes before rain occurs, the amount of water vapor in the atmosphere at 1 km height increases. Monitoring the small-scale temporal and spatial variability of PWV is therefore crucial to improve the weather now- and forecasting for convective storms, that are typically critical for urban stormwater systems. One established technique to obtain PWV measurements in the atmosphere is to exploit signal delays from GNSS satellites to dual-frequency receivers on the ground. Existing dual-frequency receiver networks typically have inter-station distances in the order of tens of kilometers, which is not sufficiently dense to capture the small-scale PWV variations. In this study, we will add low-cost, single-frequency GNSS receivers to an existing dual-frequency receiver network to obtain an inter-station distance of about 1 km in the Rotterdam area (Netherlands). The aim is to investigate the spatial variability of PWV in the atmosphere at this scale. We use the surrounding dual-frequency network (distributed over a radius of approximately 25 km) to apply an ionospheric delay model that accounts for the delay in the ionosphere (50-1000 km altitude) that cannot be eliminated by single-frequency receivers. The results are validated by co-aligning a single-frequency receiver to a dual-frequency receiver. In the next steps, we will investigate how the high temporal and increased spatial resolution network can help to improve high-resolution rainfall forecasts. Their supposed improved forecasting results will be evaluated based on high-resolution rainfall estimates from a polarimetric X-band rainfall radar installed in the city of Rotterdam.
Moore, Brian C J; Ernst, Stephan M A
2012-09-01
It is commonly believed that difference limens for frequency (DLFs) for pure tones depend on a temporal mechanism (phase locking) for frequencies up to 4-5 kHz and a place mechanism at higher frequencies. The DLFs predicted from a place mechanism, expressed as a proportion of center frequency (Δf/f), should be approximately invariant with frequency at medium to high frequencies. If there is a transition from a temporal to a place mechanism, Δf/f should increase with increasing center frequency until the transition occurs, and then reach a plateau. Published data do not show such an effect. In this study, DLFs were measured for center frequencies from 2 to 14 kHz, using earphones designed to produce a flat response at the eardrum. The level of every tone was varied over a range of ±4 dB, to reduce loudness cues. The value of Δf/f increased progressively from 2 to 8 kHz, but did not change significantly for frequencies from 8 to 14 kHz. The results are consistent with the idea that there is a transition from a temporal to a place mechanism at about 8 kHz, rather than at 4-5 kHz, as is commonly assumed.
Wang, Tao; Huang, Jiang-hua; Lin, Lin; Zhan, Chang'an A
2013-01-01
To obtain reliable transient auditory evoked potentials (AEPs) from EEGs recorded using high stimulus rate (HSR) paradigm, it is critical to design the stimulus sequences of appropriate frequency properties. Traditionally, the individual stimulus events in a stimulus sequence occur only at discrete time points dependent on the sampling frequency of the recording system and the duration of stimulus sequence. This dependency likely causes the implementation of suboptimal stimulus sequences, sacrificing the reliability of resulting AEPs. In this paper, we explicate the use of continuous-time stimulus sequence for HSR paradigm, which is independent of the discrete electroencephalogram (EEG) recording system. We employ simulation studies to examine the applicability of the continuous-time stimulus sequences and the impacts of sampling frequency on AEPs in traditional studies using discrete-time design. Results from these studies show that the continuous-time sequences can offer better frequency properties and improve the reliability of recovered AEPs. Furthermore, we find that the errors in the recovered AEPs depend critically on the sampling frequencies of experimental systems, and their relationship can be fitted using a reciprocal function. As such, our study contributes to the literature by demonstrating the applicability and advantages of continuous-time stimulus sequences for HSR paradigm and by revealing the relationship between the reliability of AEPs and sampling frequencies of the experimental systems when discrete-time stimulus sequences are used in traditional manner for the HSR paradigm.
14 CFR 1.2 - Abbreviations and symbols.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with runway alignment indicator lights. TACAN means ultra-high frequency tactical air navigational aid... touchdown zone lights. TVOR means very high frequency terminal omnirange station. V Ameans design... safety speed. VFRmeans visual flight rules. VHFmeans very high frequency. VORmeans very high frequency...
[Auditory processing and high frequency audiometry in students of São Paulo].
Ramos, Cristina Silveira; Pereira, Liliane Desgualdo
2005-01-01
Auditory processing and auditory sensibility to high Frequency sounds. To characterize the localization processes, temporal ordering, hearing patterns and detection of high frequency sounds, looking for possible relations between these factors. 32 hearing fourth grade students, born in city of São Paulo, were submitted to: a simplified evaluation of the auditory processing; duration pattern test; high frequency audiometry. Three (9,4%) individuals presented auditory processing disorder (APD) and in one of them there was the coexistence of lower hearing thresholds in high frequency audiometry. APD associated to an auditory sensibility loss in high frequencies should be further investigated.
Frequency-tunable superconducting resonators via nonlinear kinetic inductance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vissers, M. R.; Hubmayr, J.; Sandberg, M.
2015-08-10
We have designed, fabricated, and tested a frequency-tunable high-Q superconducting resonator made from a niobium titanium nitride film. The frequency tunability is achieved by injecting a DC through a current-directing circuit into the nonlinear inductor whose kinetic inductance is current-dependent. We have demonstrated continuous tuning of the resonance frequency in a 180 MHz frequency range around 4.5 GHz while maintaining the high internal quality factor Q{sub i} > 180 000. This device may serve as a tunable filter and find applications in superconducting quantum computing and measurement. It also provides a useful tool to study the nonlinear response of a superconductor. In addition,more » it may be developed into techniques for measurement of the complex impedance of a superconductor at its transition temperature and for readout of transition-edge sensors.« less
Associations Between Sleep Quality and Migraine Frequency
Lin, Yu-Kai; Lin, Guan-Yu; Lee, Jiunn-Tay; Lee, Meei-Shyuan; Tsai, Chia-Kuang; Hsu, Yu-Wei; Lin, Yu-Zhen; Tsai, Yi-Chien; Yang, Fu-Chi
2016-01-01
Abstract Migraine has been associated with sleep disturbances. Relationship between sleep quality and migraine frequency is yet to be determined. The present study aimed to investigate sleep disturbances among low-frequency, moderate-frequency, high-frequency, and chronic migraineurs, with and without auras, with well-controlled confounding variables. This cross-sectional controlled study included 357 subjects from an outpatient headache clinic in Taiwan. Standardized questionnaires were utilized to collect demographic, migraine, sleep, depression, anxiety, and restless leg syndrome characteristics in all participants. According to frequency of migraine attacks, patients were divided into 4 groups: with 1 to 4 migraine days per month, 5 to 8 migraine days in a month, 9 to 14 migraine days in a month, and >14 migraine days per month. The Pittsburgh Sleep Quality Index (PSQI) and subgroup items were used to evaluate sleep quality. The association between migraine frequency and sleep quality was investigated using multivariable linear regression and logistic regression. The PSQI total score was highest in patients with high frequent migraine (10.0 ± 3.4) and lowest in controls (7.0 ± 3.4) with a significant trend analysis (P for trend = 0.006). Migraine frequency had an independent effect on the items “Cannot get to sleep within 30 minutes” (P < 0.001), “Wake up in the middle of the night or early morning” (P < 0.001), “Bad dreams” (P = 0.001), “Pain” (P = 0.004), and “Quality of sleep” (P < 0.001). The result showed the effect of migraine frequency in both the aura-present (P for trend = 0.008) and the aura-absent subgroups (P for trend = 0.011). High migraine frequency correlates with poor sleep quality and a higher prevalence of poor sleepers. These associations occur in migraine with aura and without aura. PMID:27124064
Campo-Arias, Adalberto; Ospino, Anyelly C; Sanabria, Adriana R; Guerra, Valeria M; Caamaño, Beatriz H; Herazo, Edwin
2017-11-21
There is no information on frequency of perceived devaluation-discrimination in victims of the armed conflict in Colombia. The aim of this study was thus to determine the frequency of perceived devaluation-discrimination and associated variables among victims of the armed conflict in municipalities in the Department of Magdalena, Colombia. A cross-sectional study was conducted among victims enrolled in the Program for Psychosocial Care and Comprehensive Healthcare for Victims. Depressive symptoms were quantified with four dichotomous items (three or more were classified as high level of depressive symptoms), and perceived devaluation-discrimination was quantified with six dichotomous items (two or more were classified as high perceived devaluation-discrimination). A total of 943 adults participated (M = 47.9; SD = 14.2); 67.4%, women; 109 (11.6%) reported high level of depressive symptoms and 217 (23%) showed high perceived devaluation-discrimination. High perceived devaluation-discrimination was associated with high level of depressive symptoms (OR = 6.47; 95%CI: 4.23-9.88). In conclusion, one-fourth of the victims of the armed conflict in Magdalena reported high perceived devaluation-discrimination, which was significantly associated with high level of depressive symptoms.
Study on a Single-Stage 120 HZ Pulse Tube Cryocooler
NASA Astrophysics Data System (ADS)
Wu, Y. Z.; Gan, Z. H.; Qiu, L. M.; Chen, J.; Li, Z. P.
2010-04-01
Miniaturization of pulse tube cryocoolers is required for some particular applications where size and mass for devices are limited. In order to pack more cooling power in a small volume, higher operating frequencies are commonly used for Stirling-type pulse tube cryocoolers. To maintain high efficiency of the regenerator with a higher frequency, a higher charging pressure, smaller hydraulic diameters of regenerator material and a shorter regenerator length should be applied. A rapid growth of research and development on pulse tube cryocoolers operating at a high frequency over 100 Hz in the last 3 years has occurred. In this study, a single stage pulse tube cryocooler with 120 Hz to provide 10 W of lift at 80 K has been developed by using the numerical model, known as REGEN 3.2. Experiments performed on this cryocooler driven by a CFIC linear compressor show that a no-load temperature of 49.6 K was achieved and the net refrigeration power at 78.5 K was 8.0 W. The effect of pulse tube orientation was tested, and the copper velvet as a regenerator matrix was proposed for high frequency operation.
Auditory word recognition: extrinsic and intrinsic effects of word frequency.
Connine, C M; Titone, D; Wang, J
1993-01-01
Two experiments investigated the influence of word frequency in a phoneme identification task. Speech voicing continua were constructed so that one endpoint was a high-frequency word and the other endpoint was a low-frequency word (e.g., best-pest). Experiment 1 demonstrated that ambiguous tokens were labeled such that a high-frequency word was formed (intrinsic frequency effect). Experiment 2 manipulated the frequency composition of the list (extrinsic frequency effect). A high-frequency list bias produced an exaggerated influence of frequency; a low-frequency list bias showed a reverse frequency effect. Reaction time effects were discussed in terms of activation and postaccess decision models of frequency coding. The results support a late use of frequency in auditory word recognition.
Abnormalities of Object Visual Processing in Body Dysmorphic Disorder
Feusner, Jamie D.; Hembacher, Emily; Moller, Hayley; Moody, Teena D.
2013-01-01
Background Individuals with body dysmorphic disorder may have perceptual distortions for their appearance. Previous studies suggest imbalances in detailed relative to configural/holistic visual processing when viewing faces. No study has investigated the neural correlates of processing non-symptom-related stimuli. The objective of this study was to determine whether individuals with body dysmorphic disorder have abnormal patterns of brain activation when viewing non-face/non-body object stimuli. Methods Fourteen medication-free participants with DSM-IV body dysmorphic disorder and 14 healthy controls participated. We performed functional magnetic resonance imaging while participants matched photographs of houses that were unaltered, contained only high spatial frequency (high detail) information, or only low spatial frequency (low detail) information. The primary outcome was group differences in blood oxygen level-dependent signal changes. Results The body dysmorphic disorder group showed lesser activity in the parahippocampal gyrus, lingual gyrus, and precuneus for low spatial frequency images. There were greater activations in medial prefrontal regions for high spatial frequency images, although no significant differences when compared to a low-level baseline. Greater symptom severity was associated with lesser activity in dorsal occipital cortex and ventrolateral prefrontal cortex for normal and high spatial frequency images. Conclusions Individuals with body dysmorphic disorder have abnormal brain activation patterns when viewing objects. Hypoactivity in visual association areas for configural and holistic (low detail) elements and abnormal allocation of prefrontal systems for details is consistent with a model of imbalances in global vs. local processing. This may occur not only for appearance but also for general stimuli unrelated to their symptoms. PMID:21557897
Smallwood, Craig D; Bullock, Kevin J; Gouldstone, Andrew
2016-08-01
High-frequency airway clearance therapy is a positive pressure secretion clearance modality used in pediatric and adult applications. However, pressure attenuation across different size endotracheal tubes (ETT) has not been adequately described. This study quantifies attenuation in an in vitro model. The MetaNeb® System was used to deliver high-frequency pressure pulses to 3.0, 4.0, 6.0 and 8.0mm ID ETTs connected to a test lung during mechanical ventilation. The experimental setup included a 3D-printed trachea model and imbedded pressure sensors. The pressure attenuation (Patt%) was calculated: Patt%=[(Pproximal-Pdistal)/Pproximal]x100. The effect of pulse frequency on Pdistal and Pproximal was quantified. Patt% was inversely and linearly related to ETT ID and (y=-7.924x+74.36; R(2)=0.9917, P=.0042 for 4.0Hz pulse frequency and y=-7.382+9.445, R(2)=0.9964, P=.0018 for 3.0Hz pulse frequency). Patt% across the 3.0, 4.0, 6.0 and 8.0mm I.D. ETTs was 48.88±10.25%, 40.87±5.22%, 27.97±5.29%, and 9.90±1.9% respectively. Selecting the 4.0Hz frequency mode demonstrated higher Pproximal and Pdistal compared to the 3.0Hz frequency mode (P=.0049 and P=.0065). Observed Pdistal was <30cmH2O for all experiments. In an in vitro model, pressure attenuation was linearly related to the inner diameter of the endotracheal tube; with decreasing attenuation as the ETT size increased. Copyright © 2016 Elsevier Inc. All rights reserved.
Power conditioning system modelling for nuclear electric propulsion
NASA Astrophysics Data System (ADS)
Metcalf, Kenneth J.
1993-11-01
NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.
Power Conditioning System Modelling for Nuclear Electric Propulsion
NASA Technical Reports Server (NTRS)
Metcalf, Kenneth J.
1993-01-01
NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.
NASA Astrophysics Data System (ADS)
Qiu, Jie; Liu, Guozhen; Wolfman, Jérôme
2016-05-01
BaxSr1-xTiO3 (0.1≤x≤0.5) (BST) thin films were prepared on La1.1Sr0.9NiO4 (LSNO)/SrTiO3 (STO) structure by combinatorial pulsed laser deposition (comb-PLD). The capacitances of the Au/BST/LSNO capacitors exhibited strong frequency dependence especially when the applied frequency was higher than 10kHz. On the basis of an equivalent circuit model, we presented a theoretical simulation of the relationships between capacitance and frequency for the capacitors with different electrode serial resistances. Based on the fitting results, the observed strong frequency dependence of the measured capacitance at high frequency in our study could be ascribed to the large serial resistance of 750 Ω for oxide electrode LSNO. Further simulation studies found that large serial resistance (1000 Ω) could result in an apparent deviation from the intrinsic dielectric properties especially at high frequencies (>100kHz) for capacitors with capacitances above 1nF. Our results provide useful information for the design of all-oxide electronic devices.
Analysis of high-k spacer on symmetric underlap DG-MOSFET with Gate Stack architecture
NASA Astrophysics Data System (ADS)
Das, Rahul; Chakraborty, Shramana; Dasgupta, Arpan; Dutta, Arka; Kundu, Atanu; Sarkar, Chandan K.
2016-09-01
This paper shows the systematic study of underlap double gate (U-DG) NMOSFETs with Gate Stack (GS) under the influence of high-k spacers. In highly scaled devices, underlap is used at the Source and Drain side so as to reduce the short channel effects (SCE's), however, it significantly reduces the on current due to the increased channel resistance. To overcome these drawbacks, the use of high-k spacers is projected as one of the remedies. In this paper, the analog performance of the devices is studied on the basis of parameters like transconductance (gm), transconductance generation factor (gm/Id) and intrinsic gain (gmro). The RF performance is analyzed on the merits of intrinsic capacitance (Cgd, Cgs), resistance (Rgd, Rgs), transport delay (τm), inductance (Lsd), cutoff frequency (fT), and the maximum frequency of oscillation (fmax). The circuit performance of the devices are studied by implementing the device as the driver MOSFET in a Single Stage Common Source Amplifier. The Gain Bandwidth Product (GBW) has been analyzed from the frequency response of the circuit.
Self-reported physical activity in a rural county: a New York county health census.
Eaton, C B; Nafziger, A N; Strogatz, D S; Pearson, T A
1994-01-01
OBJECTIVES. Few studies have described physical activity in rural populations. This study describes the frequency, types, and correlates of physical activity in 29,304 free-living adults in a rural county in New York State. METHODS. Self-reported responses about regular physical activity (maintained long enough to work up a sweat) were analyzed from a private household census of Otsego County with an 86.6% response rate. RESULTS. This survey categorized 46.2% of county residents as sedentary. Walking, the most frequent choice of activity (62% of the women, 36% of the men), increased in frequency with age of respondents whereas cycling, jogging, aerobics, team sports, and swimming (listed in rank order of frequency) generally tended to decrease in frequency with age. Farmers demonstrated an increased amount of "sweat activity" compared with persons in most other occupations. CONCLUSIONS. This descriptive study of physical activity in a rural county shows that sedentary lifestyle is of high prevalence. The high frequency of walking and the gender differences in both the levels and choice of activity suggest that further research and public policy recommendations focus on these issues. PMID:8279607
The Cathode Oscillograph for the Study of Low, Medium, and High Frequencies
NASA Technical Reports Server (NTRS)
Dufour, A
1924-01-01
The object of this work has been to construct an apparatus for obtaining oscillogram of voltages and currents which are variable with respect to time and of the frequency which is constantly met in radio.
2012-01-01
Background Alcohol drinking is a risk factor for harm and disease. A low level of drinking among non-Western immigrants may lead to less alcohol-related harm and disease. The first aim of this study was to describe frequency of drinking in two generations of immigrants in Oslo, contrasting the result to drinking frequency among ethnic Norwegians. The second aim was to study how frequency of drinking among adult immigrants was associated with social interaction with their own countrymen and ethnic Norwegians, acculturation, age, gender, socioeconomic factors and the Muslim faith. Method The Oslo Health Study (HUBRO) was conducted during the period 2000 to 2002 and consisted of three separate surveys: a youth study (15-16-year-olds, a total of 7343 respondents, response rate 88.3%); adult cohorts from 30 to 75 years old (18,770 respondents, response rate 46%); the five largest immigrant groups in Oslo (aged 20–60 years, a total of 3019 respondents, response rate 39.7%). Based on these three surveys, studies of frequency of drinking in the previous year (four categories) were conducted among 15-16-year-olds and their parents’ generation, 30-60-year-old Iranians, Pakistanis, Turks and ethnic Norwegians. A structural equation model with drinking frequency as outcome was established for the adult immigrants. Results Adults and youth of ethnic Norwegian background reported more frequent alcohol use than immigrants with backgrounds from Iran, Turkey and Pakistan. Iranians reported a higher drinking frequency than Turks and Pakistanis. In the structural equation model high drinking frequency was associated with high host culture competence and social interaction, while high own culture competence was associated with low drinking frequency. Adult first-generation immigrants with a longer stay in Norway, those of a higher age, and females drank alcohol less frequently, while those with a higher level of education and work participation drank more frequently. Muslim immigrants reported a significantly lower drinking frequency than non-Muslims, although this did not apply to Iranians. Conclusions The existence and growth in Western societies of immigrant groups with low-level alcohol consumption contributed to a lower level of consumption at the population level. This may imply reduced drinking and alcohol-related harm and disease even among ethnic Norwegians. PMID:22824456
Amundsen, Ellen J
2012-07-23
Alcohol drinking is a risk factor for harm and disease. A low level of drinking among non-Western immigrants may lead to less alcohol-related harm and disease. The first aim of this study was to describe frequency of drinking in two generations of immigrants in Oslo, contrasting the result to drinking frequency among ethnic Norwegians. The second aim was to study how frequency of drinking among adult immigrants was associated with social interaction with their own countrymen and ethnic Norwegians, acculturation, age, gender, socioeconomic factors and the Muslim faith. The Oslo Health Study (HUBRO) was conducted during the period 2000 to 2002 and consisted of three separate surveys: a youth study (15-16-year-olds, a total of 7343 respondents, response rate 88.3%); adult cohorts from 30 to 75 years old (18,770 respondents, response rate 46%); the five largest immigrant groups in Oslo (aged 20-60 years, a total of 3019 respondents, response rate 39.7%). Based on these three surveys, studies of frequency of drinking in the previous year (four categories) were conducted among 15-16-year-olds and their parents' generation, 30-60-year-old Iranians, Pakistanis, Turks and ethnic Norwegians. A structural equation model with drinking frequency as outcome was established for the adult immigrants. Adults and youth of ethnic Norwegian background reported more frequent alcohol use than immigrants with backgrounds from Iran, Turkey and Pakistan. Iranians reported a higher drinking frequency than Turks and Pakistanis. In the structural equation model high drinking frequency was associated with high host culture competence and social interaction, while high own culture competence was associated with low drinking frequency. Adult first-generation immigrants with a longer stay in Norway, those of a higher age, and females drank alcohol less frequently, while those with a higher level of education and work participation drank more frequently. Muslim immigrants reported a significantly lower drinking frequency than non-Muslims, although this did not apply to Iranians. The existence and growth in Western societies of immigrant groups with low-level alcohol consumption contributed to a lower level of consumption at the population level. This may imply reduced drinking and alcohol-related harm and disease even among ethnic Norwegians.
Global Model for Asymmetric, Diode-Type Dual Frequency Capacitive Discharge
NASA Astrophysics Data System (ADS)
Kim, Jisoo; Lieberman, M. A.; Lichtenberg, A. J.
2003-10-01
Dual frequency capacitive reactors can have desirable properties for dielectric etch: low cost, robust uniformity over large areas, and control of dissociation. In the ideal case, the high frequency power controls the plasma density (ion flux) and the low frequency voltage controls the ion bombarding energy. Typical operating conditions are: discharge radius 15-30 cm, length 1-3 cm, pressure 30-200 mTorr, high frequency 27.1-160 MHz, low frequency 2-13.6 MHz, and powers of 500-3000 W for both high and low frequencies. The decoupling of the high and low frequencies is an important feature of dual frequency capacitive discharges. In this work, we describe a global (volume-averaged) model having different top and bottom plate areas that incorporates particle balance, and ohmic and stochastic heating for high and low frequencies. The model is used to obtain the decoupling of high and low frequencies and to investigate limitations to ideal decoupling. Support provided by Lam Research, NSF Grant ECS-0139956, California industries, and UC-SMART Contract SM99-10051.
Frequency response of portable PEF meters.
Hankinson, J L; Das, M K
1995-08-01
Peak expiratory flow (PEF) is a dynamic parameter and therefore requires a measuring device with a high-frequency response. This study evaluated the frequency-response characteristics of eight commercially available PEF meters, using simulated forced-expiratory maneuvers with a computer-controlled mechanical pump. Three different PEF levels were used (200, 400, and 600 L/min) at six levels of harmonic-frequency content similar to those observed in human subjects. For waveforms with higher frequency content (at the high end or above the physiologic range), the Assess, Vitalograph, Pocket Peak, and Spir-O-Flow PEF meters all overread PEF (greater than 15% difference from target values) at all three PEF levels. These results suggest that the frequency response of PEF meters is an important consideration in the selection of such meters and should be included in device requirements. The current practice of using various levels of American Thoracic Society (ATS) waveform 24 with its low-frequency content may not adequately evaluate the frequency characteristics of PEF meters. An upper range (5% of the fundamental frequency) of 12 Hz, within the range observed in normal subjects, appears to be more practical than an upper limit of 20 Hz.
Design and analysis of a new high frequency double-servo direct drive rotary valve
NASA Astrophysics Data System (ADS)
Zhu, Muzhi; Zhao, Shengdun; Li, Jingxiang
2016-12-01
Researchers have investigated direct drive valve for many years to solve problems, such as fluid force imbalance and switching frequency. The structure of the rotary valve has received considerable research interest because of its favorable dynamic properties and simple structure. This paper studied the high frequency doubleservo direct drive rotary valve (DDRV), and proposed a novel structure and drive method satisfying high reversing frequency and adequate quantity of flow. Servo motors are integrated into the valve by the innovative structure, which is designed to equilibrate the unbalanced radial fluid force with the symmetric distributed oil ports. Aside from the fast reversing function of the valve, the DDRV presented high performance in linearity of the flow quantity and valve opening as a result of the fan-shaped flow ports. In addition, a computational fluid dynamics (CFD) method based on Fluent was conducted to verify the flux regulation effect of the height change of the adjustable boss.
Addressing the unit of analysis in medical care studies: a systematic review.
Calhoun, Aaron W; Guyatt, Gordon H; Cabana, Michael D; Lu, Downing; Turner, David A; Valentine, Stacey; Randolph, Adrienne G
2008-06-01
We assessed the frequency that patients are incorrectly used as the unit of analysis among studies of physicians' patient care behavior in articles published in high impact journals. We surveyed 30 high-impact journals across 6 medical fields for articles susceptible to unit of analysis errors published from 1994 to 2005. Three reviewers independently abstracted articles using previously published criteria to determine the presence of analytic errors. One hundred fourteen susceptible articles were found published in 15 journals, 4 journals published the majority (71 of 114 or 62.3%) of studies, 40 were intervention studies, and 74 were noninterventional studies. The unit of analysis error was present in 19 (48%) of the intervention studies and 31 (42%) of the noninterventional studies (overall error rate 44%). The frequency of the error decreased between 1994-1999 (N = 38; 65% error) and 2000-2005 (N = 76; 33% error) (P = 0.001). Although the frequency of the error in published studies is decreasing, further improvement remains desirable.
NASA Astrophysics Data System (ADS)
Djidel, S.; Bouamar, M.; Khedrouche, D.
2016-04-01
This paper presents a performances study of UWB monopole antenna using half-elliptic radiator conformed on elliptical surface. The proposed antenna, simulated using microwave studio computer CST and High frequency simulator structure HFSS, is designed to operate in frequency interval over 3.1 to 40 GHz. Good return loss and radiation pattern characteristics are obtained in the frequency band of interest. The proposed antenna structure is suitable for ultra-wideband applications, which is, required for many wearable electronics applications.
The relative immunity of high-frequency transposed stimuli to low-frequency binaural interference
NASA Astrophysics Data System (ADS)
Bernstein, Leslie R.; Trahiotis, Constantine
2004-05-01
We have recently demonstrated that high-frequency transposed stimuli, having envelopes designed to provide high-frequency channels with information similar to that normally available in only low-frequency channels, yield threshold-ITDs and extents of laterality comparable to those obtained with conventional low-frequency stimuli. This enhanced potency of ITDs conveyed by high-frequency transposed stimuli, as compared to conventional high-frequency stimuli, suggested to us that ITDs conveyed by transposed stimuli might be relatively immune to the presence of low-frequency binaural interferers. To investigate this issue, threshold-ITDs and extents of laterality were measured with a variety of conventional and transposed targets centered at 4 kHz. The targets were presented either in the presence or absence of a simultaneously gated diotic noise centered at 500 Hz, the interferer. As expected, the presence of the low-frequency interferer resulted in substantially elevated threshold-ITDs and reduced extents of laterality for the conventional high-frequency stimuli. In contrast, these interference effects were either greatly attenuated or absent for ITDs conveyed by the high-frequency transposed targets. The results will be discussed in the context of current models of binaural interference. [Work supported by NIH DC 04147, NIH DC04073, NIH DC 002304.
Maharjan, Ashim; Wang, Eunice; Peng, Mei; Cakmak, Yusuf O.
2018-01-01
In past literature on animal models, invasive vagal nerve stimulation using high frequencies has shown to be effective at modulating the activity of the olfactory bulb (OB). Recent advances in invasive vagal nerve stimulation in humans, despite previous findings in animal models, used low frequency stimulation and found no effect on the olfactory functioning. The present article aimed to test potential effects of non-invasive, high and low frequency vagal nerve stimulation in humans, with supplementary exploration of the orbitofrontal cortex using near-infrared spectroscopy (NIRS). Healthy, male adult participants (n = 18) performed two olfactory tests [odor threshold test (OTT) and supra-threshold test (STT)] before and after receiving high-, low frequency vagal nerve stimulation and placebo (no stimulation). Participant's olfactory functioning was monitored using NIRS, and assessed with two behavioral olfactory tests. NIRS data of separate stimulation parameters were statistically analyzed using repeated-measures ANOVA across different stages. Data from olfactory tests were analyzed using paired parametric and non-parametric statistical tests. Only high frequency, non-invasive vagal nerve stimulation was able to positively modulate the performance of the healthy participants in the STT (p = 0.021, Wilcoxon sign-ranked test), with significant differences in NIRS (p = 0.014, post-hoc with Bonferroni correction) recordings of the right hemispheric, orbitofrontal cortex. The results from the current article implore further exploration of the neurocircuitry involved under vagal nerve stimulation and the effects of non-invasive, high frequency, vagal nerve stimulation toward olfactory dysfunction which showcase in Parkinson's and Alzheimer's Diseases. Despite the sufficient effect size (moderate effect, correlation coefficient (r): 0.39 for the STT) of the current study, future research should replicate the current findings with a larger cohort. PMID:29740266
Maharjan, Ashim; Wang, Eunice; Peng, Mei; Cakmak, Yusuf O
2018-01-01
In past literature on animal models, invasive vagal nerve stimulation using high frequencies has shown to be effective at modulating the activity of the olfactory bulb (OB). Recent advances in invasive vagal nerve stimulation in humans, despite previous findings in animal models, used low frequency stimulation and found no effect on the olfactory functioning. The present article aimed to test potential effects of non-invasive, high and low frequency vagal nerve stimulation in humans, with supplementary exploration of the orbitofrontal cortex using near-infrared spectroscopy (NIRS). Healthy, male adult participants ( n = 18) performed two olfactory tests [odor threshold test (OTT) and supra-threshold test (STT)] before and after receiving high-, low frequency vagal nerve stimulation and placebo (no stimulation). Participant's olfactory functioning was monitored using NIRS, and assessed with two behavioral olfactory tests. NIRS data of separate stimulation parameters were statistically analyzed using repeated-measures ANOVA across different stages. Data from olfactory tests were analyzed using paired parametric and non-parametric statistical tests. Only high frequency, non-invasive vagal nerve stimulation was able to positively modulate the performance of the healthy participants in the STT ( p = 0.021, Wilcoxon sign-ranked test), with significant differences in NIRS ( p = 0.014, post-hoc with Bonferroni correction ) recordings of the right hemispheric, orbitofrontal cortex. The results from the current article implore further exploration of the neurocircuitry involved under vagal nerve stimulation and the effects of non-invasive, high frequency, vagal nerve stimulation toward olfactory dysfunction which showcase in Parkinson's and Alzheimer's Diseases. Despite the sufficient effect size (moderate effect, correlation coefficient (r): 0.39 for the STT) of the current study, future research should replicate the current findings with a larger cohort.
NASA Astrophysics Data System (ADS)
Wang, Chong; Wen, Na; Zhou, Guoyun; Wang, Shouxu; He, Wei; Su, Xinhong; Hu, Yongsuan
2017-11-01
A novel method of improving the adhesion between copper and prepreg in high frequency PCB was proposed and studied in this work. This process which aimed to decrease the IEP (isoelectric point) of the copper to obtain higher adhesion, was achieved by depositing a thin tin layer with lower IEP on copper. It was characterized by scanning electron microscopy (SEM), 3D microscope, peel strength test, X-Ray thickness test, grazing incidence X-ray diffraction (GXRD), X-ray photoelectron spectroscopy (XPS), Agilent vector network analyzer (VNA), which confirmed its excellent adhesion performance and outstanding electrical properties in high-frequency signal transmission compared with traditional brown oxide method. Moreover, the mechanism of achieving high adhesion for this method was also investigated.
Hearing diversity in moths confronting a neotropical bat assemblage.
Cobo-Cuan, Ariadna; Kössl, Manfred; Mora, Emanuel C
2017-09-01
The tympanal ear is an evolutionary acquisition which helps moths survive predation from bats. The greater diversity of bats and echolocation strategies in the Neotropics compared with temperate zones would be expected to impose different sensory requirements on the neotropical moths. However, even given some variability among moth assemblages, the frequencies of best hearing of moths from different climate zones studied to date have been roughly the same: between 20 and 60 kHz. We have analyzed the auditory characteristics of tympanate moths from Cuba, a neotropical island with high levels of bat diversity and a high incidence of echolocation frequencies above those commonly at the upper limit of moths' hearing sensitivity. Moths of the superfamilies Noctuoidea, Geometroidea and Pyraloidea were examined. Audiograms were determined by non-invasively measuring distortion-product otoacoustic emissions. We also quantified the frequency spectrum of the echolocation sounds to which this moth community is exposed. The hearing ranges of moths in our study showed best frequencies between 36 and 94 kHz. High sensitivity to frequencies above 50 kHz suggests that the auditory sensitivity of moths is suited to the sounds used by sympatric echolocating bat fauna. Biodiversity characterizes predators and prey in the Neotropics, but the bat-moth acoustic interaction keeps spectrally matched.
Temporal epilepsy seizures monitoring and prediction using cross-correlation and chaos theory.
Haddad, Tahar; Ben-Hamida, Naim; Talbi, Larbi; Lakhssassi, Ahmed; Aouini, Sadok
2014-01-01
Temporal seizures due to hippocampal origins are very common among epileptic patients. Presented is a novel seizure prediction approach employing correlation and chaos theories. The early identification of seizure signature allows for various preventive measures to be undertaken. Electro-encephalography signals are spectrally broken down into the following sub-bands: delta; theta; alpha; beta; and gamma. The proposed approach consists of observing a high correlation level between any pair of electrodes for the lower frequencies and a decrease in the Lyapunov index (chaos or entropy) for the higher frequencies. Power spectral density and statistical analysis tools were used to determine threshold levels for the lower frequencies. After studying all five sub-bands, the analysis has revealed that the seizure signature can be extracted from the delta band and the high frequencies. High frequencies are defined as both the gamma band and the ripples occurring within the 60-120 Hz sub-band. To validate the proposed approach, six patients from both sexes and various age groups with temporal epilepsies originating from the hippocampal area were studied using the Freiburg database. An average seizure prediction of 30 min, an anticipation accuracy of 72%, and a false-positive rate of 0% were accomplished throughout 200 h of recording time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garipov, G. K., E-mail: ggkmsu@yandex.ru; Panasyuk, M. I.; Svertilov, S. I.
2016-09-15
The generation of transients in the Earth’s upper atmosphere under the action of electron fluxes and high- and low-frequency electromagnetic waves has been studied onboard the small Vernov spacecraft (solar synchronous orbit, 98° inclination, height 640–830 km). The studies were carried out with ultraviolet (UV, 240–380 nm), red–infrared (IR, 610–800 nm), gamma-ray (0.01–3 MeV), and electron (0.2–15 MeV) detectors as well as with high-frequency (0.05–15 MHz) and low-frequency (0.1 Hz–40 kHz) radio receivers. Artificial optical signals distributed along the meridian in an extended region of latitudes in the Earth’s Northern and Southern Hemispheres modulated by a low frequency were recordedmore » during the nadir observations at nighttime. Examples of the oscillograms of such signals in the UV and IR spectral ranges and their global distribution are presented. The emission generation altitude and the atmospheric components that can be the sources of this emission are discussed. Particular attention is given to the technogenic causes of this glow in the ionosphere under the action of powerful low- and high-frequency radio stations on the ionosphere.« less
He, Longbiao; Yang, Ping; Li, Luming; Wu, Minsheng
2014-12-01
To solve the difficulty of introducing traditional ultrasonic transducers to welding molten pool, high frequency current is used to modulate plasma arc and ultrasonic wave is excited successfully. The characteristics of the excited ultrasonic field are studied. The results show that the amplitude-frequency response of the ultrasonic emission is flat. The modulating current is the main factor influencing the ultrasonic power and the sound pressure depends on the variation of arc plasma stream force. Experimental study of the welding structure indicates grain refinement by the ultrasonic emission of the modulated arc and the test results showed there should be an energy region for the arc ultrasonic to get best welding joints. Copyright © 2014 Elsevier B.V. All rights reserved.
Kelishadi, Roya; Mirmoghtadaee, Parisa; Qorbani, Mostafa; Motlagh, Mohammad Esmaeil; Heshmat, Ramin; Taslimi, Mahnaz; Mahmoudarabi, Minoosadat; Ardalan, Gelayol; Larijani, Bagher
2013-01-01
Background: A growing body of evidence supports an association between oral health and cardiovascular diseases and diabetes in adults. This study aimed to investigate the relationship between tooth brushing frequency and cardiometabolic risk factors in adolescents. Methods: This nationwide population-based study was conducted among 5258 Iranian students, aged 10-18 years, living in urban and rural areas of 27 provinces in Iran. The association of tooth brushing frequency was assessed with anthropometric indexes and cardiometabolic risk factors after adjustment for potential confounders. Results: Higher frequency of tooth brushing was associated with lower mean levels of low-density lipoprotein cholesterol (LDL-C) in both genders (P < 0.0001) and lower frequency of elevated LDL-C in girls (P = 0.03). The frequency of elevated blood pressure decreased with higher tooth brushing frequency in boys (P = 0.03). After adjustment for many potential cofounders such as age, gender, anthropometric indexes, screen time, socioeconomic status, and family history of non-communicable diseases, participants who washed their teeth at least once a day had lower risk of high LDL-C and low high-density lipoprotein cholesterol (HDL-C) levels in comparison to those who reported lower frequency of tooth brushing; some different associations were observed among girls and boys. Conclusions: Our findings suggest an independent and protective role of teeth brushing frequency for some cardiometabolic risk factors in adolescents. Increasing both the general health awareness and improving oral health should be considered in primordial and primary prevention of non-communicable diseases. PMID:23626883
Low-Frequency Waves in HF Heating of the Ionosphere
NASA Astrophysics Data System (ADS)
Sharma, A. S.; Eliasson, B.; Milikh, G. M.; Najmi, A.; Papadopoulos, K.; Shao, X.; Vartanyan, A.
2016-02-01
Ionospheric heating experiments have enabled an exploration of the ionosphere as a large-scale natural laboratory for the study of many plasma processes. These experiments inject high-frequency (HF) radio waves using high-power transmitters and an array of ground- and space-based diagnostics. This chapter discusses the excitation and propagation of low-frequency waves in HF heating of the ionosphere. The theoretical aspects and the associated models and simulations, and the results from experiments, mostly from the HAARP facility, are presented together to provide a comprehensive interpretation of the relevant plasma processes. The chapter presents the plasma model of the ionosphere for describing the physical processes during HF heating, the numerical code, and the simulations of the excitation of low-frequency waves by HF heating. It then gives the simulations of the high-latitude ionosphere and mid-latitude ionosphere. The chapter also briefly discusses the role of kinetic processes associated with wave generation.
Jia, Jun; Li, Bo; Sun, Zuo-Li; Yu, Fen; Wang, Xuan; Wang, Xiao-Min
2010-04-01
The role of electro-acupuncture (EA) stimulation on motor symptoms in Parkinson's disease (PD) has not been well studied. In a rat hemiparkinsonian model induced by unilateral transection of the medial forebrain bundle (MFB), EA stimulation improved motor impairment in a frequency-dependent manner. Whereas EA stimulation at a low frequency (2 Hz) had no effect, EA stimulation at a high frequency (100 Hz) significantly improved motor coordination. However, neither low nor high EA stimulation could significantly enhance dopamine levels in the striatum. EA stimulation at 100 Hz normalized the MFB lesion-induced increase in midbrain GABA content, but it had no effect on GABA content in the globus pallidus. These results suggest that high-frequency EA stimulation improves motor impairment in MFB-lesioned rats by increasing GABAergic inhibition in the output structure of the basal ganglia.
Calibration of ultra-high frequency (UHF) partial discharge sensors using FDTD method
NASA Astrophysics Data System (ADS)
Ishak, Asnor Mazuan; Ishak, Mohd Taufiq
2018-02-01
Ultra-high frequency (UHF) partial discharge sensors are widely used for conditioning monitoring and defect location in insulation system of high voltage equipment. Designing sensors for specific applications often requires an iterative process of manufacturing, testing and mechanical modifications. This paper demonstrates the use of finite-difference time-domain (FDTD) technique as a tool to predict the frequency response of UHF PD sensors. Using this approach, the design process can be simplified and parametric studies can be conducted in order to assess the influence of component dimensions and material properties on the sensor response. The modelling approach is validated using gigahertz transverse electromagnetic (GTEM) calibration system. The use of a transient excitation source is particularly suitable for modeling using FDTD, which is able to simulate the step response output voltage of the sensor from which the frequency response is obtained using the same post-processing applied to the physical measurement.
The Effects of Visual Complexity for Japanese Kanji Processing with High and Low Frequencies
ERIC Educational Resources Information Center
Tamaoka, Katsuo; Kiyama, Sachiko
2013-01-01
The present study investigated the effects of visual complexity for kanji processing by selecting target kanji from different stroke ranges of visually simple (2-6 strokes), medium (8-12 strokes), and complex (14-20 strokes) kanji with high and low frequencies. A kanji lexical decision task in Experiment 1 and a kanji naming task in Experiment 2…
High frequency power distribution system
NASA Technical Reports Server (NTRS)
Patel, Mikund R.
1986-01-01
The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.
Chapin, Thomas
2015-01-01
Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.
Cheron, Julian; Cheron, Guy
2018-02-20
The cerebellum displays various sorts of rhythmic activities covering both low- and high-frequency oscillations. These cerebellar high-frequency oscillations were observed in the cerebellar cortex. Here, we hypothesised that not only is the cerebellar cortex a generator of high-frequency oscillations but also that the deep cerebellar nuclei may also play a similar role. Thus, we analysed local field potentials and single-unit activities in the deep cerebellar nuclei before, during and after electric stimulation in the inferior olive of awake mice. A high-frequency oscillation of 350 Hz triggered by the stimulation of the inferior olive, within the beta-gamma range, was observed in the deep cerebellar nuclei. The amplitude and frequency of the oscillation were independent of the frequency of stimulation. This oscillation emerged during the period of stimulation and persisted after the end of the stimulation. The oscillation coincided with the inhibition of deep cerebellar neurons. As the inhibition of the deep cerebellar nuclei is related to inhibitory inputs from Purkinje cells, we speculate that the oscillation represents the unmasking of the synchronous activation of another subtype of deep cerebellar neuronal subtype, devoid of GABA receptors and under the direct control of the climbing fibres from the inferior olive. Still, the mechanism sustaining this oscillation remains to be deciphered. Our study sheds new light on the role of the olivo-cerebellar loop as the final output control of the intercerebellar circuitry. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)
NASA Astrophysics Data System (ADS)
Livaoǧlu, Hamdullah; Irmak, T. Serkan; Caka, Deniz; Yavuz, Evrim; Lühr, B. G.; Woith, H.; Tunç, B.; Baris, S.
2016-04-01
The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see if any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.
NASA Astrophysics Data System (ADS)
Hedlund, Brock E.; Houpt, Alec W.; Gordeyev, Stanislav V.; Leonov, Sergey B.
2017-10-01
This study was performed to characterize the dominant frequencies present in the boundary layer uptsream of and in the corner separation zone of a compression surface in Mach 4.5 flow and to determine a control effect of transient plasma actuation on the boundary layer. Schlieren imaging was used to distinguish the corner separation zone for 20°, 25°, and 30° compression ramps mounted on flat plates. Spectra of the natural disturbances present in the boundary layer and separation zone were gathered using a high-speed Shack-Hartmann wavefront sensor and surface mounted PCBTM pressure sensors while varying flow parameters by adjusting total pressure, temperature, and ramp angle. Shallow cavity discharge plasma actuators were used as a high-frequency localized thermal forcing mechanism of the boundary layer. The plasma effect was negligible for forcing frequencies (50 kHz) below the natural dominant frequency (~55-80 kHz). High frequency perturbations that can promote the transition to turbulence were amplified when the plasma forcing frequency (100 kHz) was higher than the natural dominant frequency (~55-80 kHz). This technique can potentially be used for active control of hypersonic boundary layer transition and the supersonic flow structure on the compression surface.
Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Eckberg, D. L.
1998-01-01
We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.
Zhuang, Jun; Vargas-Irwin, Carlos; Donoghue, John P.
2011-01-01
Intracortical microelectrode array recordings generate a variety of neural signals with potential application as control signals in neural interface systems. Previous studies have focused on single and multiunit activity, as well as low frequency local field potentials (LFPs), but have not explored higher frequency (>200 Hz) LFPs. In addition, the potential to decode three dimensional (3-D) reach and grasp kinematics based on LFPs has not been demonstrated. Here, we use mutual information and decoding analyses to probe the information content about 3-D reaching and grasping of 7 different LFP frequency bands in the range of 0.3 Hz – 400 Hz. LFPs were recorded via 96-microelectrode arrays in primary motor cortex (M1) of two monkeys performing free reaching to grasp moving objects. Mutual information analyses revealed that higher frequency bands (e.g. 100 – 200 Hz and 200 – 400 Hz) carried the most information about the examined kinematics. Furthermore, Kalman filter decoding revealed that broadband high frequency LFPs, likely reflecting multiunit activity, provided the best decoding performance as well as substantial accuracy in reconstructing reach kinematics, grasp aperture and aperture velocity. These results indicate that LFPs, especially high frequency bands, could be useful signals for neural interfaces controlling 3-D reach and grasp kinematics. PMID:20403782
Miller, Patrick J O; Samarra, Filipa I P; Perthuison, Aurélie D
2007-06-01
This study investigates how particular received spectral characteristics of stereotyped calls of sexually dimorphic adult killer whales may be influenced by caller sex, orientation, and range. Calls were ascribed to individuals during natural behavior using a towed beamforming array. The fundamental frequency of both high-frequency and low-frequency components did not differ consistently by sex. The ratio of peak energy within the fundamental of the high-frequency component relative to summed peak energy in the first two low-frequency component harmonics, and the number of modulation bands off the high-frequency component, were significantly greater when whales were oriented towards the array, while range and adult sex had little effect. In contrast, the ratio of peak energy in the first versus second harmonics of the low-frequency component was greater in calls produced by adult females than adult males, while orientation and range had little effect. The dispersion of energy across harmonics has been shown to relate to body size or sex in terrestrial species, but pressure effects during diving are thought to make such a signal unreliable in diving animals. The observed spectral differences by signaler sex and orientation suggest that these types of information may be transmitted acoustically by freely diving killer whales.
Solmi, M; Gallicchio, D; Collantoni, E; Correll, C U; Clementi, M; Pinato, C; Forzan, M; Cassina, M; Fontana, F; Giannunzio, V; Piva, I; Siani, R; Salvo, P; Santonastaso, P; Tenconi, E; Veronese, N; Favaro, A
2016-06-01
Objectives Growing interest focuses on the association between 5-HTTLPR polymorphism and eating disorders (ED), but published findings have been conflicting. Methods The Italian BIO.VE.D.A. biobank provided 976 samples (735 ED patients and 241 controls) for genotyping. We conducted a literature search of studies published up to 1 April 2015, including studies reporting on 5HTTLPR genotype and allele frequencies in obesity and/or ED. We ran a meta-analysis, including data from BIO.VE.D.A. - comparing low and high-functioning genotype and allele frequencies in ED vs. Results Data from 21 studies, plus BIO.VE.D.A., were extracted providing information from 3,736 patients and 2,707 controls. Neither low- nor high-functioning genotype frequencies in ED patients, with both bi- and tri-allelic models, differed from controls. Furthermore, neither low- nor high-functioning allele frequencies in ED or in BN, in both bi- and triallelic models, differed from control groups. After sensitivity analysis, results were the same in AN vs. Results remained unaltered when investigating recessive and dominant models. Conclusions 5HTTLPR does not seem to be associated with ED in general, or with AN or BN in particular. Future studies in ED should explore the role of ethnicity and psychiatric comorbidity as a possible source of bias.
Berengut, J C; Dzuba, V A; Flambaum, V V
2010-09-17
We study atomic systems that are in the frequency range of optical atomic clocks and have enhanced sensitivity to potential time variation of the fine-structure constant α. The high sensitivity is due to coherent contributions from three factors: high nuclear charge Z, high ionization degree, and significant differences in the configuration composition of the states involved. Configuration crossing keeps the frequencies in the optical range despite the large ionization energies. We discuss a few promising examples that have the largest α sensitivities seen in atomic systems.
Effect of centrifugal force on natural frequency of lateral vibration of rotating shafts
NASA Astrophysics Data System (ADS)
Behzad, M.; Bastami, A. R.
2004-07-01
This paper investigates the effect of shaft rotation on its natural frequency. Apart from gyroscopic effect, the axial force originated from centrifugal force and the Poisson effect results in change of shaft natural frequency. D'Alembert principle for shaft in cylindrical co-ordinate system, along with the stress-strain relation, gives the non-homogenous linear differential equation, which can be used to calculate axial stress in the shaft. Numerical results of this study show that axial stress produced by shaft rotation has a major effect on the natural frequency of long high-speed shafts, while shaft diameter has no influence on the results. In addition, change in lateral natural frequency due to gyroscopic effect is compared with the results of this study.
Tsujino, Jiromaru; Hongoh, Misugi; Yoshikuni, Masafumi; Hashii, Hidekazu; Ueoka, Tetsugi
2004-04-01
The welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems that are driven at only the fundamental-resonance frequency vibration were compared, and also those of the welding systems that were driven at the fundamental and several higher resonance frequencies simultaneously were studied. At high frequency, welding characteristics can be improved due to the larger vibration loss of plastic materials. For welding of rather thin or small specimens, as the fundamental frequency of these welding systems is higher and the numbers of driven higher frequencies are driven simultaneously, larger welded area and weld strength were obtained.
High pressure study on layered nitride superconductors
NASA Astrophysics Data System (ADS)
Taguchi, Y.; Hisakabe, M.; Ohishi, Y.; Yamanaka, S.; Iwasa, Y.
2004-03-01
Pressure dependence of critical temperature, lattice constant, and phonon frequency has been investigated for layered nitride superconductors, Li_0.5(THF)_yHfNCl and ZrNCl_0.7. The data have been analyzed in terms of MacMillan's theory, and electron-phonon coupling constant λ (=1.3), Coulomb pseudopotential μ^* (=0.31), and relevant phonon frequency (=630 cm-1) have been extracted. The obtained value of λ exceeds 1 in contrast with previous experimental and theoretical results. The present result indicates that, if the superconductivity is within a MacMillan scheme, it is mediated by high frequency phonons in a strong coupling regime.
NASA Astrophysics Data System (ADS)
Cruz, Wellington; Szpigel, Sérgio; Kaufmann, Pierre; Raulin, Jean-Pierre; Klopf, Michael
2017-10-01
Recent observations of solar flares at high-frequencies have provided evidence of a new spectral component with fluxes increasing with frequency in the sub-THz to THz range. This new component occurs simultaneously but is separated from the well-known microwave spectral component that maximizes at frequencies of a few to tens of GHz. The aim of this work is to study in detail a mechanism recently suggested to describe the double-spectrum feature observed in solar flares based on the physical process known as microbunching instability, which occurs with high-energy electron beams in laboratory accelerators.
Modelling switching-time effects in high-frequency power conditioning networks
NASA Technical Reports Server (NTRS)
Owen, H. A.; Sloane, T. H.; Rimer, B. H.; Wilson, T. G.
1979-01-01
Power transistor networks which switch large currents in highly inductive environments are beginning to find application in the hundred kilohertz switching frequency range. Recent developments in the fabrication of metal-oxide-semiconductor field-effect transistors in the power device category have enhanced the movement toward higher switching frequencies. Models for switching devices and of the circuits in which they are imbedded are required to properly characterize the mechanisms responsible for turning on and turning off effects. Easily interpreted results in the form of oscilloscope-like plots assist in understanding the effects of parametric studies using topology oriented computer-aided analysis methods.
Li, Songhai; Wang, Ding; Wang, Kexiong; Hoffmann-Kuhnt, Matthias; Fernando, Nimal; Taylor, Elizabeth A; Lin, Wenzhi; Chen, Jialin; Ng, Timothy
2016-01-01
The hearing of a stranded Indo-Pacific humpback dolphin (Sousa chinensis) in Zhuhai, China, was measured. The age of this animal was estimated to be ~40 years. The animal's hearing was measured using a noninvasive auditory evoked potential (AEP) method. The results showed that the high-frequency hearing cutoff frequency of the studied dolphin was ~30-40 kHz lower than that of a conspecific younger individual ~13 year old. The lower high-frequency hearing range in the older dolphin was explained as a likely result of age-related hearing loss (presbycusis).
Scalable fabrication of self-aligned graphene transistors and circuits on glass.
Liao, Lei; Bai, Jingwei; Cheng, Rui; Zhou, Hailong; Liu, Lixin; Liu, Yuan; Huang, Yu; Duan, Xiangfeng
2012-06-13
Graphene transistors are of considerable interest for radio frequency (rf) applications. High-frequency graphene transistors with the intrinsic cutoff frequency up to 300 GHz have been demonstrated. However, the graphene transistors reported to date only exhibit a limited extrinsic cutoff frequency up to about 10 GHz, and functional graphene circuits demonstrated so far can merely operate in the tens of megahertz regime, far from the potential the graphene transistors could offer. Here we report a scalable approach to fabricate self-aligned graphene transistors with the extrinsic cutoff frequency exceeding 50 GHz and graphene circuits that can operate in the 1-10 GHz regime. The devices are fabricated on a glass substrate through a self-aligned process by using chemical vapor deposition (CVD) grown graphene and a dielectrophoretic assembled nanowire gate array. The self-aligned process allows the achievement of unprecedented performance in CVD graphene transistors with a highest transconductance of 0.36 mS/μm. The use of an insulating substrate minimizes the parasitic capacitance and has therefore enabled graphene transistors with a record-high extrinsic cutoff frequency (> 50 GHz) achieved to date. The excellent extrinsic cutoff frequency readily allows configuring the graphene transistors into frequency doubling or mixing circuits functioning in the 1-10 GHz regime, a significant advancement over previous reports (∼20 MHz). The studies open a pathway to scalable fabrication of high-speed graphene transistors and functional circuits and represent a significant step forward to graphene based radio frequency devices.
Kumon, R. E.; Gudur, M. S. R.; Zhou, Y.; Deng, C. X.
2012-01-01
Effective real-time monitoring of high-intensity focused ultrasound (HIFU) ablation is important for application of HIFU technology in interventional electrophysiology. This study investigated rapid, high-frequency M-mode ultrasound imaging for monitoring spatiotemporal changes during HIFU application. HIFU (4.33 MHz, 1 kHz PRF, 50% duty cycle, 1 s, 2600 – 6100 W/cm2) was applied to ex-vivo porcine cardiac tissue specimens with a confocally and perpendicularly aligned high-frequency imaging system (Visualsonics Vevo 770, 55 MHz center frequency). Radiofrequency (RF) data from M-mode imaging (1 kHz PRF, 2 s × 7 mm) was acquired before, during, and after HIFU treatment (n = 12). Among several strategies, the temporal maximum integrated backscatter with a threshold of +12 dB change showed the best results for identifying final lesion width (receiver-operating characteristic curve area 0.91 ± 0.04, accuracy 85 ± 8%, as compared to macroscopic images of lesions). A criterion based on a line-to-line decorrelation coefficient is proposed for identification of transient gas bodies. PMID:22341055
Schurr, M O; Wehrmann, M; Kunert, W; Melzer, A; Lirici, M M; Trapp, R; Kanehira, E; Buess, G
1994-01-01
Precise cutting combined with reliable coagulation of the margins of the lesion is an important requirement for dissection techniques in endoscopic surgery. These requirements are met by the two most common ancillary energy sources applied for endoscopic dissection today, electrosurgery and "thermal lasers", mostly the Nd:YAG. For the comparison of the histological effects of monopolar and bipolar high frequency with the Nd:YAG laser an experimental in vitro and in vivo study has been performed. In order to evaluate the advantages of non thermal dissection for endoscopic procedures, a water jet cutting system was included in the in vitro study. In parenchymatous tissue the water jet was found to be the least traumatic technique, followed by bipolar high frequency, laser and monopolar high frequency. The water jet was not applicable for intestinal dissection since uncontrolled bloating of the rectal wall with uncontrolled disruption of the tissue layers occurred. A general disadvantage is that secure haemostasis in the line of incision is hard to achieve. In the microscopic comparison of the shape of the incision, the Nd:YAG laser produced the smoothest lesions with well-defined margins. The monopolar technique was more often associated with irregular and sometimes fissured margins. These results were confirmed in the in vivo part of the study (Transanal Endoscopic Microsurgery).
Larsson, Matilda; Heyde, Brecht; Kremer, Florence; Brodin, Lars-Åke; D'hooge, Jan
2015-02-01
Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long- and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L/MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p<0.001) for radial strain, 0.73 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p<0.001) for radial strain, 0.93 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Nullomers and High Order Nullomers in Genomic Sequences
Vergni, Davide; Santoni, Daniele
2016-01-01
A nullomer is an oligomer that does not occur as a subsequence in a given DNA sequence, i.e. it is an absent word of that sequence. The importance of nullomers in several applications, from drug discovery to forensic practice, is now debated in the literature. Here, we investigated the nature of nullomers, whether their absence in genomes has just a statistical explanation or it is a peculiar feature of genomic sequences. We introduced an extension of the notion of nullomer, namely high order nullomers, which are nullomers whose mutated sequences are still nullomers. We studied different aspects of them: comparison with nullomers of random sequences, CpG distribution and mean helical rise. In agreement with previous results we found that the number of nullomers in the human genome is much larger than expected by chance. Nevertheless antithetical results were found when considering a random DNA sequence preserving dinucleotide frequencies. The analysis of CpG frequencies in nullomers and high order nullomers revealed, as expected, a high CpG content but it also highlighted a strong dependence of CpG frequencies on the dinucleotide position, suggesting that nullomers have their own peculiar structure and are not simply sequences whose CpG frequency is biased. Furthermore, phylogenetic trees were built on eleven species based on both the similarities between the dinucleotide frequencies and the number of nullomers two species share, showing that nullomers are fairly conserved among close species. Finally the study of mean helical rise of nullomers sequences revealed significantly high mean rise values, reinforcing the hypothesis that those sequences have some peculiar structural features. The obtained results show that nullomers are the consequence of the peculiar structure of DNA (also including biased CpG frequency and CpGs islands), so that the hypermutability model, also taking into account CpG islands, seems to be not sufficient to explain nullomer phenomenon. Finally, high order nullomers could emphasize those features that already make simple nullomers useful in several applications. PMID:27906971
Radhakrishnan, Rajan; Sluka, Kathleen A
2005-10-01
In this study we investigated the involvement of cutaneous versus knee joint afferents in the antihyperalgesia produced by transcutaneous electrical nerve stimulation (TENS) by differentially blocking primary afferents with local anesthetics. Hyperalgesia was induced in rats by inflaming one knee joint with 3% kaolin-carrageenan and assessed by measuring paw withdrawal latency to heat before and 4 hours after injection. Skin surrounding the inflamed knee joint was anesthetized using an anesthetic cream (EMLA). Low (4 Hz) or high (100 Hz) frequency TENS was then applied to the anesthetized skin. In another group, 2% lidocaine gel was injected into the inflamed knee joint, and low or high frequency TENS was applied. Control experiments were done using vehicles. In control and EMLA groups, both low and high frequency TENS completely reversed hyperalgesia. However, injection of lidocaine into the knee joint prevented antihyperalgesia produced by both low and high frequency TENS. Recordings of cord dorsum potentials showed that both low and high frequency TENS at sensory intensity activates only large diameter afferent fibers. Increasing intensity to twice the motor threshold recruits Adelta afferent fibers. Furthermore, application of EMLA cream to the skin reduces the amplitude of the cord dorsum potential by 40% to 70% for both high and low frequency TENS, confirming a loss of large diameter primary afferent input after EMLA is applied to the skin. Thus, inactivation of joint afferents, but not cutaneous afferents, prevents the antihyperalgesia effects of TENS. We conclude that large diameter primary afferent fibers from deep tissue are required and that activation of cutaneous afferents is not sufficient for TENS-induced antihyperalgesia. Transcutaneous electrical nerve stimulation (TENS) is an accepted clinical modality used for pain relief. It is generally believed that TENS analgesia is caused mainly by cutaneous afferent activation. In this study by differentially blocking cutaneous and deep tissue primary afferents, we show that the activation of large diameter primary afferents from deep somatic tissues, and not cutaneous afferents, are pivotal in causing TENS analgesia.
Sikes, Anita L; Mawson, Raymond; Stark, Janet; Warner, Robyn
2014-11-01
The delivery of a consistent quality product to the consumer is vitally important for the food industry. The aim of this study was to investigate the potential for using high frequency ultrasound applied to pre- and post-rigor beef muscle on the metabolism and subsequent quality. High frequency ultrasound (600kHz at 48kPa and 65kPa acoustic pressure) applied to post-rigor beef striploin steaks resulted in no significant effect on the texture (peak force value) of cooked steaks as measured by a Tenderometer. There was no added benefit of ultrasound treatment above that of the normal ageing process after ageing of the steaks for 7days at 4°C. Ultrasound treatment of post-rigor beef steaks resulted in a darkening of fresh steaks but after ageing for 7days at 4°C, the ultrasound-treated steaks were similar in colour to that of the aged, untreated steaks. High frequency ultrasound (2MHz at 48kPa acoustic pressure) applied to pre-rigor beef neck muscle had no effect on the pH, but the calculated exhaustion factor suggested that there was some effect on metabolism and actin-myosin interaction. However, the resultant texture of cooked, ultrasound-treated muscle was lower in tenderness compared to the control sample. After ageing for 3weeks at 0°C, the ultrasound-treated samples had the same peak force value as the control. High frequency ultrasound had no significant effect on the colour parameters of pre-rigor beef neck muscle. This proof-of-concept study showed no effect of ultrasound on quality but did indicate that the application of high frequency ultrasound to pre-rigor beef muscle shows potential for modifying ATP turnover and further investigation is warranted. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Singh, Harshvardhan; Whitney, Daniel G; Knight, Christopher A; Miller, Freeman; Manal, Kurt; Kolm, Paul; Modlesky, Christopher M
2016-02-01
To determine the degree to which a high-frequency, low-magnitude vibration signal emitted by a floor-based platform transmits to the distal tibia and distal femur of children with spastic cerebral palsy (CP) during standing. Cross-sectional study. University research laboratory. Children with spastic CP who could stand independently (n=18) and typically developing children (n=10) (age range, 4-12y) participated in the study (N=28). Not applicable. The vibration signal at the high-frequency, low-magnitude vibration platform (approximately 33Hz and 0.3g), distal tibia, and distal femur was measured using accelerometers. The degree of plantar flexor spasticity was assessed using the Modified Ashworth Scale. The high-frequency, low-magnitude vibration signal was greater (P<.001) at the distal tibia than at the platform in children with CP (.36±.06g vs .29±.05g) and controls (.40±.09g vs .24±.07g). Although the vibration signal was also higher at the distal femur (.35±.09g, P<.001) than at the platform in controls, it was lower in children with CP (.20±.07g, P<.001). The degree of spasticity was negatively related to the vibration signal transmitted to the distal tibia (Spearman ρ=-.547) and distal femur (Spearman ρ=-.566) in children with CP (both P<.05). A high-frequency, low-magnitude vibration signal from a floor-based platform was amplified at the distal tibia, attenuated at the distal femur, and inversely related to the degree of muscle spasticity in children with spastic CP. Whether this transmission pattern affects the adaptation of the bones of children with CP to high-frequency, low-magnitude vibration requires further investigation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Kuffner, Tamara; Whitworth, William; Jairam, Maya; McNicholl, Janet
2003-06-01
Knowledge of population major histocompatibility complex gene frequencies is important for construction of organ donor pools and for studies of disease association. Human leukocyte antigen DRB1 (HLA-DRB1), HLA-DQB1, and TNFalpha -308 (G-A) promoter genetic typing was performed in 112 healthy, unrelated African Americans (AAs) from the southeastern United States. Allele frequencies were compared with published frequency data from other AA populations. Our AA population had the highest frequency of HLA- DRB1*09 (6.7%) reported in any AA population. The frequency of the TNF alpha -308A polymorphism was also high (14.4%), when compared with published frequencies in AAs. Significant regional differences in the distribution of most HLA-DRB1 and HLA-DQB1 alleles were observed in all AA populations examined. The AA HLA-DRB1 and -DQB1 frequencies also differed from published Caucasian frequencies. This is the first report describing the distribution of TNF alpha promoter alleles in the Southeastern United States. The high DRB1*09 and TNF alpha -308A allele frequencies of our population most resemble the frequencies of these alleles in certain West African populations. These varying major histocompatibility complex gene frequencies may reflect different regional population structures among AAs in the United States, which may be due to differences in ancestral origins, migration, and racial admixture.
Monitoring method and apparatus using high-frequency carrier
Haynes, Howard D.
1996-01-01
A method and apparatus for monitoring an electrical-motor-driven device by injecting a high frequency carrier signal onto the power line current. The method is accomplished by injecting a high frequency carrier signal onto an AC power line current. The AC power line current supplies the electrical-motor-driven device with electrical energy. As a result, electrical and mechanical characteristics of the electrical-motor-driven device modulate the high frequency carrier signal and the AC power line current. The high frequency carrier signal is then monitored, conditioned and demodulated. Finally, the modulated high frequency carrier signal is analyzed to ascertain the operating condition of the electrical-motor-driven device.
Study on ion energy distribution in low-frequency oscillation time scale of Hall thrusters
NASA Astrophysics Data System (ADS)
Wei, Liqiu; Li, Wenbo; Ding, Yongjie; Han, Liang; Yu, Daren; Cao, Yong
2017-11-01
This paper reports on the dynamic characteristics of the distribution of ion energy during Hall thruster discharge in the low-frequency oscillation time scale through experimental studies, and a statistical analysis of the time-varying peak and width of ion energy and the ratio of high-energy ions during the low-frequency oscillation. The results show that the ion energy distribution exhibits a periodic change during the low-frequency oscillation. Moreover, the variation in the ion energy peak is opposite to that of the discharge current, and the variations in width of the ion energy distribution and the ratio of high-energy ions are consistent with that of the discharge current. The variation characteristics of the ion density and discharge potential were simulated by one-dimensional hybrid-direct kinetic simulations; the simulation results and analysis indicate that the periodic change in the distribution of ion energy during the low-frequency oscillation depends on the relationship between the ionization source term and discharge potential distribution during ionization in the discharge channel.
Zonana-Nacach, Abraham; Castillón-Chapa, Mario Arturo
2006-01-01
Assess the frequency of the metabolic syndrome (MS) among overweight and obese subjects attending a primary health care clinic in Tijuana, Baja California, Mexico. Male and female patients over 20 years of age attending a primary health care setting during April-Sept 2004 were selected to participate in the study. Metabolic syndrome was defined using the Adult Treatment Panel III criteria (NCEP III). Three-hundred twenty one patients with a mean age 47.9 years were assessed. The MS frequency was 44% for those patients without previous history of diabetes mellitus or hypertension (n = 281). The MS was present in 30% and 53% of overweight and obese patients respectively. Being an older male who had not been born in Baja California State were significantly associated with the presence of MS. The frequency of MS in a selected group of patients was common and higher than the national prevalence. The high frequency of MS in our study could be associated with a high prevalence of diabetes and obesity in the northwest population of Mexico.
Analysis of different techniques to improve sound transmission loss in cylindrical shells
NASA Astrophysics Data System (ADS)
Oliazadeh, Pouria; Farshidianfar, Anooshiravan
2017-02-01
In this study, sound transmission through double- and triple-walled shells is investigated. The structure-acoustic equations based on Donnell's shell theory are presented and transmission losses calculated by this approach are compared with the transmission losses obtained according to Love's theory. An experimental set-up is also constructed to compare natural frequencies obtained from Donnell and Love's theories with experimental results in the high frequency region. Both comparisons show that Donnell's theory predicts the sound transmission characteristics and vibrational behavior better than Love's theory in the high frequency region. The transmission losses of the double- and triple-walled construction are then presented for various radii and thicknesses. Then the effects of air gap size as an important design parameter are studied. Sound transmission characteristics through a circular cylindrical shell are also computed along with consideration of the effects of material damping. Modest absorption is shown to greatly reduce the sound transmission at ring frequency and coincidence frequency. Also the effects of five common gases that are used for filling the gap are investigated.