Sample records for sublinear dose dependence

  1. Dose response relationship in anti-stress gene regulatory networks.

    PubMed

    Zhang, Qiang; Andersen, Melvin E

    2007-03-02

    To maintain a stable intracellular environment, cells utilize complex and specialized defense systems against a variety of external perturbations, such as electrophilic stress, heat shock, and hypoxia, etc. Irrespective of the type of stress, many adaptive mechanisms contributing to cellular homeostasis appear to operate through gene regulatory networks that are organized into negative feedback loops. In general, the degree of deviation of the controlled variables, such as electrophiles, misfolded proteins, and O2, is first detected by specialized sensor molecules, then the signal is transduced to specific transcription factors. Transcription factors can regulate the expression of a suite of anti-stress genes, many of which encode enzymes functioning to counteract the perturbed variables. The objective of this study was to explore, using control theory and computational approaches, the theoretical basis that underlies the steady-state dose response relationship between cellular stressors and intracellular biochemical species (controlled variables, transcription factors, and gene products) in these gene regulatory networks. Our work indicated that the shape of dose response curves (linear, superlinear, or sublinear) depends on changes in the specific values of local response coefficients (gains) distributed in the feedback loop. Multimerization of anti-stress enzymes and transcription factors into homodimers, homotrimers, or even higher-order multimers, play a significant role in maintaining robust homeostasis. Moreover, our simulation noted that dose response curves for the controlled variables can transition sequentially through four distinct phases as stressor level increases: initial superlinear with lesser control, superlinear more highly controlled, linear uncontrolled, and sublinear catastrophic. Each phase relies on specific gain-changing events that come into play as stressor level increases. The low-dose region is intrinsically nonlinear, and depending on the level of local gains, presence of gain-changing events, and degree of feedforward gene activation, this region can appear as superlinear, sublinear, or even J-shaped. The general dose response transition proposed here was further examined in a complex anti-electrophilic stress pathway, which involves multiple genes, enzymes, and metabolic reactions. This work would help biologists and especially toxicologists to better assess and predict the cellular impact brought about by biological stressors.

  2. Foam on troubled water: Capillary induced finite-time arrest of sloshing waves

    NASA Astrophysics Data System (ADS)

    Viola, Francesco; Brun, P.-T.; Dollet, Benjamin; Gallaire, François

    2016-09-01

    Interfacial forces exceed gravitational forces on a scale small relative to the capillary length—two millimeters in the case of an air-water interface—and therefore dominate the physics of sub-millimetric systems. They are of paramount importance for various biological taxa and engineering processes where the motion of a liquid meniscus induces a viscous frictional force that exhibits a sublinear dependence in the meniscus velocity, i.e., a power law with an exponent smaller than one. Interested in the fundamental implications of this dependence, we use a liquid-foam sloshing system as a prototype to exacerbate the effect of sublinear friction on the macroscopic mechanics of multi-phase flows. In contrast to classical theory, we uncover the existence of a finite-time singularity in our system yielding the arrest of the fluid's oscillations. We propose a minimal theoretical framework to capture this effect, thereby amending the paradigmatic damped harmonic oscillator model. Our results suggest that, although often not considered at the macroscale, sublinear capillary forces govern the friction at liquid-solid and liquid-liquid interfaces.

  3. Average Weighted Receiving Time of Weighted Tetrahedron Koch Networks

    NASA Astrophysics Data System (ADS)

    Dai, Meifeng; Zhang, Danping; Ye, Dandan; Zhang, Cheng; Li, Lei

    2015-07-01

    We introduce weighted tetrahedron Koch networks with infinite weight factors, which are generalization of finite ones. The term of weighted time is firstly defined in this literature. The mean weighted first-passing time (MWFPT) and the average weighted receiving time (AWRT) are defined by weighted time accordingly. We study the AWRT with weight-dependent walk. Results show that the AWRT for a nontrivial weight factor sequence grows sublinearly with the network order. To investigate the reason of sublinearity, the average receiving time (ART) for four cases are discussed.

  4. Dose-responses for mortality from cerebrovascular and heart diseases in atomic bomb survivors: 1950-2003.

    PubMed

    Schöllnberger, Helmut; Eidemüller, Markus; Cullings, Harry M; Simonetto, Cristoforo; Neff, Frauke; Kaiser, Jan Christian

    2018-03-01

    The scientific community faces important discussions on the validity of the linear no-threshold (LNT) model for radiation-associated cardiovascular diseases at low and moderate doses. In the present study, mortalities from cerebrovascular diseases (CeVD) and heart diseases from the latest data on atomic bomb survivors were analyzed. The analysis was performed with several radio-biologically motivated linear and nonlinear dose-response models. For each detrimental health outcome one set of models was identified that all fitted the data about equally well. This set was used for multi-model inference (MMI), a statistical method of superposing different models to allow risk estimates to be based on several plausible dose-response models rather than just relying on a single model of choice. MMI provides a more accurate determination of the dose response and a more comprehensive characterization of uncertainties. It was found that for CeVD, the dose-response curve from MMI is located below the linear no-threshold model at low and medium doses (0-1.4 Gy). At higher doses MMI predicts a higher risk compared to the LNT model. A sublinear dose-response was also found for heart diseases (0-3 Gy). The analyses provide no conclusive answer to the question whether there is a radiation risk below 0.75 Gy for CeVD and 2.6 Gy for heart diseases. MMI suggests that the dose-response curves for CeVD and heart diseases in the Lifespan Study are sublinear at low and moderate doses. This has relevance for radiotherapy treatment planning and for international radiation protection practices in general.

  5. Contribution of sublinear and supralinear dendritic integration to neuronal computations

    PubMed Central

    Tran-Van-Minh, Alexandra; Cazé, Romain D.; Abrahamsson, Therése; Cathala, Laurence; Gutkin, Boris S.; DiGregorio, David A.

    2015-01-01

    Nonlinear dendritic integration is thought to increase the computational ability of neurons. Most studies focus on how supralinear summation of excitatory synaptic responses arising from clustered inputs within single dendrites result in the enhancement of neuronal firing, enabling simple computations such as feature detection. Recent reports have shown that sublinear summation is also a prominent dendritic operation, extending the range of subthreshold input-output (sI/O) transformations conferred by dendrites. Like supralinear operations, sublinear dendritic operations also increase the repertoire of neuronal computations, but feature extraction requires different synaptic connectivity strategies for each of these operations. In this article we will review the experimental and theoretical findings describing the biophysical determinants of the three primary classes of dendritic operations: linear, sublinear, and supralinear. We then review a Boolean algebra-based analysis of simplified neuron models, which provides insight into how dendritic operations influence neuronal computations. We highlight how neuronal computations are critically dependent on the interplay of dendritic properties (morphology and voltage-gated channel expression), spiking threshold and distribution of synaptic inputs carrying particular sensory features. Finally, we describe how global (scattered) and local (clustered) integration strategies permit the implementation of similar classes of computations, one example being the object feature binding problem. PMID:25852470

  6. Multichannel dosemeter and Al2O3:C optically stimulated luminescence fibre sensors for use in radiation therapy: evaluation with electron beams.

    PubMed

    Magne, S; Auger, L; Bordy, J M; de Carlan, L; Isambert, A; Bridier, A; Ferdinand, P; Barthe, J

    2008-01-01

    This article proposes an innovative multichannel optically stimulated luminescence (OSL) dosemeter for on-line in vivo dose verification in radiation therapy. OSL fibre sensors incorporating small Al(2)O(3):C fibre crystals (TLD(500)) have been tested with an X-ray generator. A reproducible readout procedure should reduce the fading-induced uncertainty ( approximately - 1% per decade). OSL readouts are temperature-dependent [ approximately 0.3% K(-1) when OSL stimulation is performed at the same temperature as irradiation; approximately 0.16% K(-1) after thermalisation (20 degrees C)]. Sensor calibration and depth-dose measurements with electron beams have been performed with a Saturne 43 linear accelerator in reference conditions at CEA-LNHB (ionising radiation reference laboratory in France). Predosed OSL sensors show a good repeatability in multichannel operation and independence versus electron energy in the range (9, 18 MeV). The difference between absorbed doses measured by OSL and an ionisation chamber were within +/-0.9% (for a dose of about 1 Gy) despite a sublinear calibration curve.

  7. Asymmetric temporal integration of layer 4 and layer 2/3 inputs in visual cortex.

    PubMed

    Hang, Giao B; Dan, Yang

    2011-01-01

    Neocortical neurons in vivo receive concurrent synaptic inputs from multiple sources, including feedforward, horizontal, and feedback pathways. Layer 2/3 of the visual cortex receives feedforward input from layer 4 and horizontal input from layer 2/3. Firing of the pyramidal neurons, which carries the output to higher cortical areas, depends critically on the interaction of these pathways. Here we examined synaptic integration of inputs from layer 4 and layer 2/3 in rat visual cortical slices. We found that the integration is sublinear and temporally asymmetric, with larger responses if layer 2/3 input preceded layer 4 input. The sublinearity depended on inhibition, and the asymmetry was largely attributable to the difference between the two inhibitory inputs. Interestingly, the asymmetric integration was specific to pyramidal neurons, and it strongly affected their spiking output. Thus via cortical inhibition, the temporal order of activation of layer 2/3 and layer 4 pathways can exert powerful control of cortical output during visual processing.

  8. Deviation from additivity in mixture toxicity: relevance of nonlinear dose-response relationships and cell line differences in genotoxicity assays with combinations of chemical mutagens and gamma-radiation.

    PubMed

    Lutz, Werner K; Vamvakas, Spyros; Kopp-Schneider, Annette; Schlatter, Josef; Stopper, Helga

    2002-12-01

    Sublinear dose-response relationships are often seen in toxicity testing, particularly with bioassays for carcinogenicity. This is the result of a superimposition of various effects that modulate and contribute to the process of cancer formation. Examples are saturation of detoxification pathways or DNA repair with increasing dose, or regenerative hyperplasia and indirect DNA damage as a consequence of high-dose cytotoxicity and cell death. The response to a combination treatment can appear to be supra-additive, although it is in fact dose-additive along a sublinear dose-response curve for the single agents. Because environmental exposure of humans is usually in a low-dose range and deviation from linearity is less likely at the low-dose end, combination effects should be tested at the lowest observable effect levels (LOEL) of the components. This principle has been applied to combinations of genotoxic agents in various cellular models. For statistical analysis, all experiments were analyzed for deviation from additivity with an n-factor analysis of variance with an interaction term, n being the number of components tested in combination. Benzo[a]pyrene, benz[a]anthracene, and dibenz[a,c]anthracene were tested at the LOEL, separately and in combination, for the induction of revertants in the Ames test, using Salmonella typhimurium TA100 and rat liver S9 fraction. Combined treatment produced no deviation from additivity. The induction of micronuclei in vitro was investigated with ionizing radiation from a 137Cs source and ethyl methanesulfonate. Mouse lymphoma L5178Y cells revealed a significant 40% supra-additive combination effect in an experiment based on three independent replicates for controls and single and combination treatments. On the other hand, two human lymphoblastoid cell lines (TK6 and WTK1) as well as a pilot study with human primary fibroblasts from fetal lung did not show deviation from additivity. Data derived from one cell line should therefore not be generalized. Regarding the testing of mixtures for deviation from additive toxicity, the suggested experimental protocol is easily followed by toxicologists.

  9. A diamond detector in the dosimetry of high-energy electron and photon beams.

    PubMed

    Laub, W U; Kaulich, T W; Nüsslin, F

    1999-09-01

    A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rate was found. Detector current and dose rate are related by the expression i alpha Ddelta, where i is the detector current, D is the dose rate and delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.

  10. Multichannel Dosimeter and α-Al2O3:C Optically Stimulated Luminescence (OSL) Fiber Sensors for Use in Radiation Therapy—Evaluation With Photon Beams

    NASA Astrophysics Data System (ADS)

    Magne, Sylvian; de Carlan, Loïc; Bordy, Jean-Marc; Isambert, Aurélie; Bridier, André; Ferdinand, Pierre

    2011-04-01

    A multichannel OSL fiber optic dosimeter based on optically stimulated luminescence (OSL) of alumina is proposed for online in vivo dosimetry (IVD) in radiation therapy (RT). Two types of dosimetric-grade Al2O3:C crystals are compared and show different behavior according to manufacturing process. Metrological validations have been performed with a Saturne 43 LINAC in reference conditions at CEA LIST LNHB (French Ionizing Radiation Reference Laboratory). The dose response of OSL integrals under photon beam irradiation (6, 12, and 20 MV) show sublinearity behavior modeled by second-order equations and exhibit a small energy dependence (between 0.7% and 1.4%), explained by a modified intermediate cavity model adapted to a LINAC photon spectrum. Preclinical tests at Institut Gustave Roussy (IGR) prove that a proper design for a PMMA build-up cap leads to a low dependence vs photon beam orientation (± 1.5% and ± 0.9%) and vs field size in view of surface measurements.

  11. High- to low-dose extrapolation: critical determinants involved in the dose response of carcinogenic substances.

    PubMed

    Swenberg, J A; Richardson, F C; Boucheron, J A; Deal, F H; Belinsky, S A; Charbonneau, M; Short, B G

    1987-12-01

    Recent investigations on mechanism of carcinogenesis have demonstrated important quantitative relationships between the induction of neoplasia, the molecular dose of promutagenic DNA adducts and their efficiency for causing base-pair mismatch, and the extent of cell proliferation in target organ. These factors are involved in the multistage process of carcinogenesis, including initiation, promotion, and progression. The molecular dose of DNA adducts can exhibit supralinear, linear, or sublinear relationships to external dose due to differences in absorption, biotransformation, and DNA repair at high versus low doses. In contrast, increased cell proliferation is a common phenomena that is associated with exposures to relatively high doses of toxic chemicals. As such, it enhances the carcinogenic response at high doses, but has little effect at low doses. Since data on cell proliferation can be obtained for any exposure scenario and molecular dosimetry studies are beginning to emerge on selected chemical carcinogens, methods are needed so that these critical factors can be utilized in extrapolation from high to low doses and across species. The use of such information may provide a scientific basis for quantitative risk assessment.

  12. High- to low-dose extrapolation: critical determinants involved in the dose response of carcinogenic substances.

    PubMed Central

    Swenberg, J A; Richardson, F C; Boucheron, J A; Deal, F H; Belinsky, S A; Charbonneau, M; Short, B G

    1987-01-01

    Recent investigations on mechanism of carcinogenesis have demonstrated important quantitative relationships between the induction of neoplasia, the molecular dose of promutagenic DNA adducts and their efficiency for causing base-pair mismatch, and the extent of cell proliferation in target organ. These factors are involved in the multistage process of carcinogenesis, including initiation, promotion, and progression. The molecular dose of DNA adducts can exhibit supralinear, linear, or sublinear relationships to external dose due to differences in absorption, biotransformation, and DNA repair at high versus low doses. In contrast, increased cell proliferation is a common phenomena that is associated with exposures to relatively high doses of toxic chemicals. As such, it enhances the carcinogenic response at high doses, but has little effect at low doses. Since data on cell proliferation can be obtained for any exposure scenario and molecular dosimetry studies are beginning to emerge on selected chemical carcinogens, methods are needed so that these critical factors can be utilized in extrapolation from high to low doses and across species. The use of such information may provide a scientific basis for quantitative risk assessment. PMID:3447904

  13. Thermoluminescence and glow curves analysis of γ-exposed Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Palvi; Bedyal, A.K.; Kumar, Vinay, E-mail: vinaykdhiman@yahoo.com

    2016-01-15

    Highlights: • First time, a detailed comparative study of the glow curves and kinetic parameters was made on K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor. • Combustion method was employed to synthesize the Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor. • The nanophosphor exhibited sublinear response suggesting that it is suitable for TL dosimetry. - Abstract: Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor was synthesized by combustion synthesis using urea as a fuel. The crystal structure and particle morphology of the nanophosphor were investigated by using X-ray diffraction and transmission electron microscopy, respectively. A Thermoluminescence (TL) study was carried outmore » after exposing the samples to gamma radiation. The TL glow curves exhibited a prominent peak at 407 K and a small hump at 478 K. The intensity of the peaks increased with the increase in the dose of the gamma rays (0.01–5 kGy). The K{sub 3}Y(PO{sub 4}){sub 2}: Eu{sup 3+} (2.5 mol%) nanophosphor exhibited sublinear TL response to γ-radiation over a wide range of gamma doses (0.01–5 kGy). The TLanal program was used to analyze the glow curves of the K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor at different doses (0.2–5 kGy) and different heating rates (3–10 K/s). A comparative study was done for kinetic trapping parameters that were determined by the peak shape methods of Chen, Grossweiner and Lushchik. The frequency factors (s) for each glow peak were also calculated. The values of the activation energy (E) obtained by the TLanal program were in good agreement with those obtained by the peak shape methods. The effect of different amount of doses and different heating rates are discussed.« less

  14. Terahertz and Microwave Devices Based on the Photo-Excited Low Dimensional Electronic System

    DTIC Science & Technology

    2015-03-11

    Morphology of Thermally Annealed Copper Foils for Graphene Growth, Chemistry of Materials , (05 2013): 1643. doi : 10.1021/cm400032h R. G. Mani, J...connected specimens, IEEE Transactions on Nanotechnology, (01 2011): 179. doi : Jesús Iñarrea, R. Mani, W. Wegscheider. Sublinear radiation power...dependence of photoexcited resistance oscillations in two-dimensional electron systems, Physical Review B, (11 2010): 0. doi : 10.1103/PhysRevB

  15. Short Round Sub-Linear Zero-Knowledge Argument for Linear Algebraic Relations

    NASA Astrophysics Data System (ADS)

    Seo, Jae Hong

    Zero-knowledge arguments allows one party to prove that a statement is true, without leaking any other information than the truth of the statement. In many applications such as verifiable shuffle (as a practical application) and circuit satisfiability (as a theoretical application), zero-knowledge arguments for mathematical statements related to linear algebra are essentially used. Groth proposed (at CRYPTO 2009) an elegant methodology for zero-knowledge arguments for linear algebraic relations over finite fields. He obtained zero-knowledge arguments of the sub-linear size for linear algebra using reductions from linear algebraic relations to equations of the form z = x *' y, where x, y ∈ Fnp are committed vectors, z ∈ Fp is a committed element, and *' : Fnp × Fnp → Fp is a bilinear map. These reductions impose additional rounds on zero-knowledge arguments of the sub-linear size. The round complexity of interactive zero-knowledge arguments is an important measure along with communication and computational complexities. We focus on minimizing the round complexity of sub-linear zero-knowledge arguments for linear algebra. To reduce round complexity, we propose a general transformation from a t-round zero-knowledge argument, satisfying mild conditions, to a (t - 2)-round zero-knowledge argument; this transformation is of independent interest.

  16. Highly sensitive Europium doped SrSO4 OSL nanophosphor for radiation dosimetry applications

    NASA Astrophysics Data System (ADS)

    Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.

    2015-10-01

    Highly sensitive Europium doped SrSO4 optically stimulated luminescent (OSL) phosphor was developed by synthesizing a nano phosphor which is treated at 1000 °C. Excellent OSL properties are observed in the developed phosphor and the sensitivity is found to be 1.26 times to that of the commercial Al2O3:C (Landauer Inc.) phosphor based on area integration method. The sample showed a single TL glow peak around 230 °C which is found to reduce by 47% after the OSL readout. Sublinear dose response with the saturation around 100 mGy is observed in this sample which suggests that it is extremely sensitive and hence will be suitable in detecting very low dose levels. Minimum measurable dose on the used set up is estimated to be 1.42 μGy. Practically no fading is observed for first ten days and the phosphor has excellent reusability. High sensitivity, low fading, excellent reusability will make this phosphor suitable for radiation dosimetry applications using OSL.

  17. Absolute instabilities of travelling wave solutions in a Keller-Segel model

    NASA Astrophysics Data System (ADS)

    Davis, P. N.; van Heijster, P.; Marangell, R.

    2017-11-01

    We investigate the spectral stability of travelling wave solutions in a Keller-Segel model of bacterial chemotaxis with a logarithmic chemosensitivity function and a constant, sublinear, and linear consumption rate. Linearising around the travelling wave solutions, we locate the essential and absolute spectrum of the associated linear operators and find that all travelling wave solutions have parts of the essential spectrum in the right half plane. However, we show that in the case of constant or sublinear consumption there exists a range of parameters such that the absolute spectrum is contained in the open left half plane and the essential spectrum can thus be weighted into the open left half plane. For the constant and sublinear consumption rate models we also determine critical parameter values for which the absolute spectrum crosses into the right half plane, indicating the onset of an absolute instability of the travelling wave solution. We observe that this crossing always occurs off of the real axis.

  18. Interpreting the sub-linear Kennicutt-Schmidt relationship: the case for diffuse molecular gas

    NASA Astrophysics Data System (ADS)

    Shetty, Rahul; Clark, Paul C.; Klessen, Ralf S.

    2014-08-01

    Recent statistical analysis of two extragalactic observational surveys strongly indicate a sub-linear Kennicutt-Schmidt (KS) relationship between the star formation rate (ΣSFR) and molecular gas surface density (Σmol). Here, we consider the consequences of these results in the context of common assumptions, as well as observational support for a linear relationship between ΣSFR and the surface density of dense gas. If the CO traced gas depletion time (τ_dep^CO) is constant, and if CO only traces star-forming giant molecular clouds (GMCs), then the physical properties of each GMC must vary, such as the volume densities or star formation rates. Another possibility is that the conversion between CO luminosity and Σmol, the XCO factor, differs from cloud-to-cloud. A more straightforward explanation is that CO permeates the hierarchical interstellar medium, including the filaments and lower density regions within which GMCs are embedded. A number of independent observational results support this description, with the diffuse gas comprising at least 30 per cent of the total molecular content. The CO bright diffuse gas can explain the sub-linear KS relationship, and consequently leads to an increasing τ_dep^CO with Σmol. If ΣSFR linearly correlates with the dense gas surface density, a sub-linear KS relationship indicates that the fraction of diffuse gas fdiff grows with Σmol. In galaxies where Σmol falls towards the outer disc, this description suggests that fdiff also decreases radially.

  19. Sublinear growth of information in DNA sequences.

    PubMed

    Menconi, Giulia

    2005-07-01

    We introduce a novel method to analyse complete genomes and recognise some distinctive features by means of an adaptive compression algorithm, which is not DNA-oriented, based on the Lempel-Ziv scheme. We study the Information Content as a function of the number of symbols encoded by the algorithm and we analyse the dictionary created by the algorithm. Preliminary results are shown concerning regions showing a sublinear type of information growth, which is strictly connected to the presence of highly repetitive subregions that might be supposed to have a regulatory function within the genome.

  20. Positivity results for indefinite sublinear elliptic problems via a continuity argument

    NASA Astrophysics Data System (ADS)

    Kaufmann, U.; Ramos Quoirin, H.; Umezu, K.

    2017-10-01

    We establish a positivity property for a class of semilinear elliptic problems involving indefinite sublinear nonlinearities. Namely, we show that any nontrivial nonnegative solution is positive for a class of problems the strong maximum principle does not apply to. Our approach is based on a continuity argument combined with variational techniques, the sub and supersolutions method and some a priori bounds. Both Dirichlet and Neumann homogeneous boundary conditions are considered. As a byproduct, we deduce some existence and uniqueness results. Finally, as an application, we derive some positivity results for indefinite concave-convex type problems.

  1. The impact of different aperture distribution models and critical stress criteria on equivalent permeability in fractured rocks

    NASA Astrophysics Data System (ADS)

    Bisdom, Kevin; Bertotti, Giovanni; Nick, Hamidreza M.

    2016-05-01

    Predicting equivalent permeability in fractured reservoirs requires an understanding of the fracture network geometry and apertures. There are different methods for defining aperture, based on outcrop observations (power law scaling), fundamental mechanics (sublinear length-aperture scaling), and experiments (Barton-Bandis conductive shearing). Each method predicts heterogeneous apertures, even along single fractures (i.e., intrafracture variations), but most fractured reservoir models imply constant apertures for single fractures. We compare the relative differences in aperture and permeability predicted by three aperture methods, where permeability is modeled in explicit fracture networks with coupled fracture-matrix flow. Aperture varies along single fractures, and geomechanical relations are used to identify which fractures are critically stressed. The aperture models are applied to real-world large-scale fracture networks. (Sub)linear length scaling predicts the largest average aperture and equivalent permeability. Barton-Bandis aperture is smaller, predicting on average a sixfold increase compared to matrix permeability. Application of critical stress criteria results in a decrease in the fraction of open fractures. For the applied stress conditions, Coulomb predicts that 50% of the network is critically stressed, compared to 80% for Barton-Bandis peak shear. The impact of the fracture network on equivalent permeability depends on the matrix hydraulic properties, as in a low-permeable matrix, intrafracture connectivity, i.e., the opening along a single fracture, controls equivalent permeability, whereas for a more permeable matrix, absolute apertures have a larger impact. Quantification of fracture flow regimes using only the ratio of fracture versus matrix permeability is insufficient, as these regimes also depend on aperture variations within fractures.

  2. High-temperature CW and pulsed operation in constricted double-heterojunction AlGaAs diode lasers

    NASA Technical Reports Server (NTRS)

    Botez, D.; Connolly, J. C.; Gilbert, D. B.

    1981-01-01

    The behavior of constricted double-heterojunction (CDH) diode lasers has been investigated up to 170 C CW and 270 C pulsed. It is found that the temperature-dependent current concentration effect responsible for low threshold-current sensitivity and temperature-invariant external differential quantum efficiency in CDH lasers saturates at about 100 C. It is also found that over a wide temperature interval (180-280 C) the threshold current density has a To value of 40-50 C and that the spontaneous emission becomes increasingly sublinear above 220 C. Both effects are believed to reflect Auger recombination.

  3. Mobile impurities in ferromagnetic liquids

    NASA Astrophysics Data System (ADS)

    Kantian, Adrian; Schollwoeck, Ulrich; Giamarchi, Thierry

    2011-03-01

    Recent work has shown that mobile impurities in one dimensional interacting systems may exhibit behaviour that differs strongly from that predicted by standard Tomonaga-Luttinger liquid theory, with the appearance of power-law divergences in the spectral function signifying sublinear diffusion of the impurity. Using time-dependent matrix product states, we investigate a range of cases of mobile impurities in systems beyond the analytically accessible examples to assess the existence of a new universality class of low-energy physics in one-dimensional systems. Correspondence: Adrian.Kantian@unige.ch This work was supported in part by the Swiss SNF under MaNEP and division II.

  4. Thermally-assisted optically stimulated luminescence from deep electron traps in α-Al2O3:C,Mg

    NASA Astrophysics Data System (ADS)

    Kalita, J. M.; Chithambo, M. L.; Polymeris, G. S.

    2017-07-01

    We report thermally-assisted optically stimulated luminescence (TA-OSL) in α-Al2O3:C,Mg. The OSL was measured at elevated temperatures between 50 and 240 °C from a sample preheated to 500 °C after irradiation to 100 Gy. That OSL could be measured even after the preheating is direct evidence of the existence of deep electron traps in α-Al2O3:C,Mg. The TA-OSL intensity goes through a peak with measurement temperature. The initial increase is ascribed to thermal assistance to optical stimulation whereas the subsequent decrease in intensity is deduced to reflect increasing incidences of non-radiative recombination, that is, thermal quenching. The activation energy for thermal assistance corresponding to a deep electron trap was estimated as 0.667 ± 0.006 eV whereas the activation energy for thermal quenching was calculated as 0.90 ± 0.04 eV. The intensity of the TA-OSL was also found to increase with irradiation dose. The dose response is sublinear from 25 to 150 Gy but saturates with further increase of dose. The TA-OSL dose response has been discussed by considering the competition for charges at the deep traps. This study incidentally shows that TA-OSL can be effectively used in dosimetry involving large doses.

  5. Engines with ideal efficiency and nonzero power for sublinear transport laws

    NASA Astrophysics Data System (ADS)

    Koning, Jesper; Indekeu, Joseph O.

    2016-11-01

    It is known that an engine with ideal efficiency (η = 1 for a chemical engine and e = eCarnot for a thermal one) has zero power because a reversible cycle takes an infinite time. However, at least from a theoretical point of view, it is possible to conceive (irreversible) engines with nonzero power that can reach ideal efficiency. Here this is achieved by replacing the usual linear transport law by a sublinear one and taking the step-function limit for the particle current (chemical engine) or heat current (thermal engine) versus the applied force. It is shown that in taking this limit exact thermodynamic inequalities relating the currents to the entropy production are not violated.

  6. Setting Age Limits for TT-OSL Dating - the Local Effect

    NASA Astrophysics Data System (ADS)

    Faershtein, G.; Porat, N.; Guralnik, B.; Matmon, A.

    2017-12-01

    Luminescence dating techniques, especially Optically Stimulated Luminescence (OSL) on quartz, are widely used for dating middle Pleistocene to late Holocene sediments from different geological settings. The dating limit of a particular luminescence method depends on signal saturation and its thermal stability. The OSL signal saturates at doses of 200 Gy, equivalent to ages of 150-300 ka. Thermally Transferred OSL (TT-OSL) is a developmental technique, which potentially extends the luminescence dating range up to 1000 ka. For the Chinese Loess Plateau, experiments have shown that the natural TT-OSL signal saturates at 2200 Gy (Chapot et al., 2016). Regarding thermal stability, different studies report a wide range of estimates (0.24-861 Ma), suggesting that the thermal lifetime of TT-OSL is (i) currently poorly constrained, and (ii) may vary both by sample and region. Here, we investigated the dating limit of TT-OSL, using quartz of Nilotic origin (Israel), obtained from two sediment sections of similar depth but different dose rates. Natural dose response curves (DRC) of the TT-OSL signal were constructed for each section separately. In both sections, luminescence intensity grows sub-linearly up to 450 Gy, beyond which it remains constant with depth. The absence of equivalent doses (De) over 600 Gy, at both sections (as well as elsewhere regionally), suggest that TT-OSL signal saturation may be an intrinsic property, related to quartz provenance, and independent of the specific ionizing dose rate at each section. The thermal stability of TT-OSL was investigated on a modern sample from one section, using a combination of analytical techniques (varying heating rates, and isothermal storage). The obtained TT-OSL lifetimes range between 105-107 ka, and reinforce a significant inter sample variability. A synthesis of our results suggests that TT-OSL ages of Nilotic quartz derived from De values over 450 Gy, are likely underestimates, and should be treated as minimum ages. The limiting value of 600 Gy for local quartz TT-OSL is likely representative of a steady-state between TT-OSL trap filling due to ionizing radiation, and the concurrent thermal empting of these traps.

  7. Anisotropic Hardy Spaces of Musielak-Orlicz Type with Applications to Boundedness of Sublinear Operators

    PubMed Central

    Li, Baode; Yang, Dachun; Yuan, Wen

    2014-01-01

    Let φ : ℝn × [0, ∞)→[0, ∞) be a Musielak-Orlicz function and A an expansive dilation. In this paper, the authors introduce the anisotropic Hardy space of Musielak-Orlicz type, H A φ(ℝn), via the grand maximal function. The authors then obtain some real-variable characterizations of H A φ(ℝn) in terms of the radial, the nontangential, and the tangential maximal functions, which generalize the known results on the anisotropic Hardy space H A p(ℝn) with p ∈ (0,1] and are new even for its weighted variant. Finally, the authors characterize these spaces by anisotropic atomic decompositions. The authors also obtain the finite atomic decomposition characterization of H A φ(ℝn), and, as an application, the authors prove that, for a given admissible triplet (φ, q, s), if T is a sublinear operator and maps all (φ, q, s)-atoms with q < ∞ (or all continuous (φ, q, s)-atoms with q = ∞) into uniformly bounded elements of some quasi-Banach spaces ℬ, then T uniquely extends to a bounded sublinear operator from H A φ(ℝn) to ℬ. These results are new even for anisotropic Orlicz-Hardy spaces on ℝn. PMID:24757418

  8. Anisotropic hardy spaces of Musielak-Orlicz type with applications to boundedness of sublinear operators.

    PubMed

    Li, Baode; Yang, Dachun; Yuan, Wen

    2014-01-01

    Let φ : ℝ(n) × [0, ∞)→[0, ∞) be a Musielak-Orlicz function and A an expansive dilation. In this paper, the authors introduce the anisotropic Hardy space of Musielak-Orlicz type, H(A)(φ)(ℝ(n)), via the grand maximal function. The authors then obtain some real-variable characterizations of H(A)(φ)(ℝ(n)) in terms of the radial, the nontangential, and the tangential maximal functions, which generalize the known results on the anisotropic Hardy space H(A)(p) (ℝ(n)) with p ∈ (0,1] and are new even for its weighted variant. Finally, the authors characterize these spaces by anisotropic atomic decompositions. The authors also obtain the finite atomic decomposition characterization of H(A)(φ)(ℝ(n)), and, as an application, the authors prove that, for a given admissible triplet (φ, q, s), if T is a sublinear operator and maps all (φ, q, s)-atoms with q < ∞ (or all continuous (φ, q, s)-atoms with q = ∞) into uniformly bounded elements of some quasi-Banach spaces ℬ, then T uniquely extends to a bounded sublinear operator from H(A)(φ)(ℝ(n)) to ℬ. These results are new even for anisotropic Orlicz-Hardy spaces on ℝ(n).

  9. Co-doped sodium chloride crystals exposed to different irradiation temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortiz-Morales, A.; Cruz-Zaragoza, E.; Furetta, C.

    2013-07-03

    Monocrystals of NaCl:XCl{sub 2}:MnCl{sub 2}(X = Ca,Cd) at four different concentrations have been analyzed. The crystals were exposed to different irradiation temperature, such as at room temperature (RT), solid water (SW), dry ice (DI) and liquid nitrogen (LN). The samples were irradiated with photon from {sup 60}Co irradiators. The co-doped sodium chloride crystals show a complex structure of glow curves that can be related to different distribution of traps. The linearity response was analyzed with the F(D) index. The F(D) value was less than unity indicating a sub-linear response was obtained from the TL response on the function of themore » dose. The glow curves were deconvoluted by using the CGCD program based on the first, second and general order kinetics.« less

  10. Biology Based Lung Cancer Model for Chronic Low Radon Exposures

    NASA Astrophysics Data System (ADS)

    TruÅ£ǎ-Popa, Lucia-Adina; Hofmann, Werner; Fakir, Hatim; Cosma, Constantin

    2008-08-01

    Low dose effects of alpha particles at the tissue level are characterized by the interaction of single alpha particles, affecting only a small fraction of the cells within that tissue. Alpha particle intersections of bronchial target cells during a given exposure period were simulated by an initiation-promotion model, formulated in terms of cellular hits within the cycle time of the cell (dose-rate) and then integrated over the whole exposure period (dose). For a given average number of cellular hits during the lifetime of bronchial cells, the actual number of single and multiple hits was selected from a Poisson distribution. While oncogenic transformation is interpreted as the primary initiation step, stimulated mitosis by killing adjacent cells is assumed to be the primary radiological promotion event. Analytical initiation and promotion functions were derived from experimental in vitro data on oncogenic transformation and cellular survival. To investigate the shape of the lung cancer risk function at chronic, low level exposures in more detail, additional biological factors describing the tissue response and operating specifically at low doses were incorporated into the initiation-promotion model. These mechanisms modifying the initial response at the cellular level were: adaptive response, genomic instability, induction of apoptosis by surrounding cells, and detrimental as well as protective bystander mechanisms. To quantify the effects of these mechanisms as functions of dose, analytical functions were derived from the experimental evidence presently available. Predictions of lung cancer risk, including these mechanisms, exhibit a distinct sublinear dose-response relationship at low exposures, particularly for very low exposure rates.

  11. Allometric scaling of microbial fuel cells and stacks: The lifeform case for scale-up

    NASA Astrophysics Data System (ADS)

    Greenman, John; Ieropoulos, Ioannis A.

    2017-07-01

    This case study reports for the first time on the comparison between allometric scaling of lifeforms and scale-up of microbial fuel cell entities; enlarging individual units in volume, footprint and electrode surface area but also multiplying a static size/footprint and electrode surface area to scale-up by stacking. A study published in 2010 by DeLong et al. showed for the first time that Kleiber's law does not apply uniformly to all lifeforms, and that in fact growth rate for prokaryotes is superlinear, for protists is linear and for metazoa is sublinear. The current study, which is utilising data from previous experiments, is showing for the first time that for individual MFC units, which are enlarged, growth rate/power is sublinear, whereas for stacks this is superlinear.

  12. Irreducible normalizer operators and thresholds for degenerate quantum codes with sublinear distances

    NASA Astrophysics Data System (ADS)

    Pryadko, Leonid P.; Dumer, Ilya; Kovalev, Alexey A.

    2015-03-01

    We construct a lower (existence) bound for the threshold of scalable quantum computation which is applicable to all stabilizer codes, including degenerate quantum codes with sublinear distance scaling. The threshold is based on enumerating irreducible operators in the normalizer of the code, i.e., those that cannot be decomposed into a product of two such operators with non-overlapping support. For quantum LDPC codes with logarithmic or power-law distances, we get threshold values which are parametrically better than the existing analytical bound based on percolation. The new bound also gives a finite threshold when applied to other families of degenerate quantum codes, e.g., the concatenated codes. This research was supported in part by the NSF Grant PHY-1416578 and by the ARO Grant W911NF-11-1-0027.

  13. B-periodic oscillations in the Hall-resistance induced by a dc-current-bias under combined microwave-excitation and dc-current bias in the GaAs/AlGaAs 2D system.

    PubMed

    Liu, Han-Chun; Reichl, C; Wegscheider, W; Mani, R G

    2018-05-18

    We report the observation of dc-current-bias-induced B-periodic Hall resistance oscillations and Hall plateaus in the GaAs/AlGaAs 2D system under combined microwave radiation- and dc bias excitation at liquid helium temperatures. The Hall resistance oscillations and plateaus appear together with concomitant oscillations also in the diagonal magnetoresistance. The periods of Hall and diagonal resistance oscillations are nearly identical, and source power (P) dependent measurements demonstrate sub-linear relationship of the oscillation amplitude with P over the span 0 < P ≤ 20 mW.

  14. Average receiving scaling of the weighted polygon Koch networks with the weight-dependent walk

    NASA Astrophysics Data System (ADS)

    Ye, Dandan; Dai, Meifeng; Sun, Yanqiu; Shao, Shuxiang; Xie, Qi

    2016-09-01

    Based on the weighted Koch networks and the self-similarity of fractals, we present a family of weighted polygon Koch networks with a weight factor r(0 < r ≤ 1) . We study the average receiving time (ART) on weight-dependent walk (i.e., the walker moves to any of its neighbors with probability proportional to the weight of edge linking them), whose key step is to calculate the sum of mean first-passage times (MFPTs) for all nodes absorpt at a hub node. We use a recursive division method to divide the weighted polygon Koch networks in order to calculate the ART scaling more conveniently. We show that the ART scaling exhibits a sublinear or linear dependence on network order. Thus, the weighted polygon Koch networks are more efficient than expended Koch networks in receiving information. Finally, compared with other previous studies' results (i.e., Koch networks, weighted Koch networks), we find out that our models are more general.

  15. Random Photon Absorption Model Elucidates How Early Gain Control in Fly Photoreceptors Arises from Quantal Sampling

    PubMed Central

    Song, Zhuoyi; Zhou, Yu; Juusola, Mikko

    2016-01-01

    Many diurnal photoreceptors encode vast real-world light changes effectively, but how this performance originates from photon sampling is unclear. A 4-module biophysically-realistic fly photoreceptor model, in which information capture is limited by the number of its sampling units (microvilli) and their photon-hit recovery time (refractoriness), can accurately simulate real recordings and their information content. However, sublinear summation in quantum bump production (quantum-gain-nonlinearity) may also cause adaptation by reducing the bump/photon gain when multiple photons hit the same microvillus simultaneously. Here, we use a Random Photon Absorption Model (RandPAM), which is the 1st module of the 4-module fly photoreceptor model, to quantify the contribution of quantum-gain-nonlinearity in light adaptation. We show how quantum-gain-nonlinearity already results from photon sampling alone. In the extreme case, when two or more simultaneous photon-hits reduce to a single sublinear value, quantum-gain-nonlinearity is preset before the phototransduction reactions adapt the quantum bump waveform. However, the contribution of quantum-gain-nonlinearity in light adaptation depends upon the likelihood of multi-photon-hits, which is strictly determined by the number of microvilli and light intensity. Specifically, its contribution to light-adaptation is marginal (≤ 1%) in fly photoreceptors with many thousands of microvilli, because the probability of simultaneous multi-photon-hits on any one microvillus is low even during daylight conditions. However, in cells with fewer sampling units, the impact of quantum-gain-nonlinearity increases with brightening light. PMID:27445779

  16. Universal scaling laws in metro area election results.

    PubMed

    Bokányi, Eszter; Szállási, Zoltán; Vattay, Gábor

    2018-01-01

    We explain the anomaly of election results between large cities and rural areas in terms of urban scaling in the 1948-2016 US elections and in the 2016 EU referendum of the UK. The scaling curves are all universal and depend on a single parameter only, and one of the parties always shows superlinear scaling and drives the process, while the sublinear exponent of the other party is merely the consequence of probability conservation. Based on the recently developed model of urban scaling, we give a microscopic model of voter behavior in which we replace diversity characterizing humans in creative aspects with social diversity and tolerance. The model can also predict new political developments such as the fragmentation of the left and the immigration paradox.

  17. Asymptotic proportionality (weak ergodicity) and conditional asymptotic equality of solutions to time-heterogeneous sublinear difference and differential equations

    NASA Astrophysics Data System (ADS)

    Thieme, Horst R.

    The concept of asymptotic proportionality and conditional asymptotic equality which is presented here aims at making global asymptotic stability statements for time-heterogeneous difference and differential equations. For such non-autonomous problems (apart from special cases) no prominent special solutions (equilibra, periodic solutions) exist which are natural candidates for the asymptotic behaviour of arbitrary solutions. One way out of this dilemma consists in looking for conditions under which any two solutions to the problem (with different initial conditions) behave in a similar or even the same way as time tends to infinity. We study a general sublinear difference equation in an ordered Banach space and, for illustration, time-heterogeneous versions of several well-known differential equations modelling the spread of gonorrhea in a heterogeneous population, the spread of a vector-borne infectious disease, and the dynamics of a logistically growing spatially diffusing population.

  18. Analysis of Classes of Singular Steady State Reaction Diffusion Equations

    NASA Astrophysics Data System (ADS)

    Son, Byungjae

    We study positive radial solutions to classes of steady state reaction diffusion problems on the exterior of a ball with both Dirichlet and nonlinear boundary conditions. We study both Laplacian as well as p-Laplacian problems with reaction terms that are p-sublinear at infinity. We consider both positone and semipositone reaction terms and establish existence, multiplicity and uniqueness results. Our existence and multiplicity results are achieved by a method of sub-supersolutions and uniqueness results via a combination of maximum principles, comparison principles, energy arguments and a-priori estimates. Our results significantly enhance the literature on p-sublinear positone and semipositone problems. Finally, we provide exact bifurcation curves for several one-dimensional problems. In the autonomous case, we extend and analyze a quadrature method, and in the nonautonomous case, we employ shooting methods. We use numerical solvers in Mathematica to generate the bifurcation curves.

  19. The scientific jigsaw puzzle: Fitting the pieces of the low-level radiation debate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beyea, Jan

    2012-05-01

    Quantitative risk estimates from exposure to ionizing radiation are dominated by analysis of the one-time exposures received by the Japanese survivors at Hiroshima and Nagasaki. Three recent epidemiologic studies suggest that the risk from protracted exposure is no lower, and in fact may be higher, than from single exposures. There is near-universal acceptance that epidemiologic data demonstrates an excess risk of delayed cancer incidence above a dose of 0.1 sievert (Sv), which, for the average American, is equivalent to 40 years of unavoidable exposure from natural background radiation. Model fits, both parametric and nonparametric, to the atomic-bomb data support amore » linear no-threshold model, below 0.1 Sv. On the basis of biologic arguments, the scientific establishment in the United States and many other countries accepts this dose-model down to zero-dose, but there is spirited dissent. The dissent may be irrelevant for developed countries, given the increase in medical diagnostic radiation that has occurred in recent decades; a sizeable percentage of this population will receive cumulative doses from the medical profession in excess of 0.1 Sv, making talk of a threshold or other sublinear response below that dose moot for future releases from nuclear facilities or a dirty bomb. The risks from both medical diagnostic doses and nuclear accident doses can be computed using the linear dose-response model, with uncertainties assigned below 0.1 Sv in a way that captures alternative scientific hypotheses. Then, the important debate over low-level radiation exposures, namely planning for accident response and weighing benefits and risks of technologies, can proceed with less distraction. One of the biggest paradoxes in the low-level radiation debate is that an individual risk can be a minor concern, while the societal risk-the total delayed cancers in an exposed population-can be of major concern.« less

  20. Universal scaling laws in metro area election results

    PubMed Central

    Szállási, Zoltán; Vattay, Gábor

    2018-01-01

    We explain the anomaly of election results between large cities and rural areas in terms of urban scaling in the 1948–2016 US elections and in the 2016 EU referendum of the UK. The scaling curves are all universal and depend on a single parameter only, and one of the parties always shows superlinear scaling and drives the process, while the sublinear exponent of the other party is merely the consequence of probability conservation. Based on the recently developed model of urban scaling, we give a microscopic model of voter behavior in which we replace diversity characterizing humans in creative aspects with social diversity and tolerance. The model can also predict new political developments such as the fragmentation of the left and the immigration paradox. PMID:29470518

  1. Static friction boost in edge-driven incommensurate contacts

    NASA Astrophysics Data System (ADS)

    Mandelli, Davide; Guerra, Roberto; Ouyang, Wengen; Urbakh, Michael; Vanossi, Andrea

    2018-04-01

    We present a numerical investigation of the size scaling of static friction in incommensurate two-dimensional contacts performed for different lateral loading configurations. Results of model simulations show that both the absolute value of the force Fs and the scaling exponent γ strongly depend on the loading configuration adopted to drive the slider along the substrate. Under edge loading, a sharp increase of static friction is observed above a critical size corresponding to the appearance of a localized commensurate dislocation. Noticeably, the existence of sublinear scaling, which is a fingerprint of superlubricity, does not conflict with the possibility to observe shear-induced localized commensurate regions at the contact interface. Atomistic simulations of gold islands sliding over graphite corroborate these findings, suggesting that similar elasticity effects should be at play in real frictional contacts.

  2. Systematic study of doping dependence on linear magnetoresistance in p-PbTe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, J. M.; Chitta, V. A.; Oliveira, N. F.

    2014-10-20

    We report on a large linear magnetoresistance effect observed in doped p-PbTe films. While undoped p-PbTe reveals a sublinear magnetoresistance, p-PbTe films doped with BaF{sub 2} exhibit a transition to a nearly perfect linear magnetoresistance behaviour that is persistent up to 30 T. The linear magnetoresistance slope ΔR/ΔB is to a good approximation, independent of temperature. This is in agreement with the theory of Quantum Linear Magnetoresistance. We also performed magnetoresistance simulations using a classical model of linear magnetoresistance. We found that this model fails to explain the experimental data. A systematic study of the doping dependence reveals that the linearmore » magnetoresistance response has a maximum for small BaF{sub 2} doping levels and diminishes rapidly for increasing doping levels. Exploiting the huge impact of doping on the linear magnetoresistance signal could lead to new classes of devices with giant magnetoresistance behavior.« less

  3. Feedforward Inhibition Allows Input Summation to Vary in Recurrent Cortical Networks

    PubMed Central

    2018-01-01

    Abstract Brain computations depend on how neurons transform inputs to spike outputs. Here, to understand input-output transformations in cortical networks, we recorded spiking responses from visual cortex (V1) of awake mice of either sex while pairing sensory stimuli with optogenetic perturbation of excitatory and parvalbumin-positive inhibitory neurons. We found that V1 neurons’ average responses were primarily additive (linear). We used a recurrent cortical network model to determine whether these data, as well as past observations of nonlinearity, could be described by a common circuit architecture. Simulations showed that cortical input-output transformations can be changed from linear to sublinear with moderate (∼20%) strengthening of connections between inhibitory neurons, but this change away from linear scaling depends on the presence of feedforward inhibition. Simulating a variety of recurrent connection strengths showed that, compared with when input arrives only to excitatory neurons, networks produce a wider range of output spiking responses in the presence of feedforward inhibition. PMID:29682603

  4. Quantification of the dielectric constant of single non-spherical nanoparticles from polarization forces: eccentricity effects.

    PubMed

    Gomila, G; Esteban-Ferrer, D; Fumagalli, L

    2013-12-20

    We analyze by means of finite-element numerical calculations the polarization force between a sharp conducting tip and a non-spherical uncharged dielectric nanoparticle with the objective of quantifying its dielectric constant from electrostatic force microscopy (EFM) measurements. We show that for an oblate spheroid nanoparticle of given height the strength of the polarization force acting on the tip depends linearly on the eccentricity, e, of the nanoparticle in the small eccentricity and low dielectric constant regimes (1 < e < 2 and 1 < ε(r) < 10), while for higher eccentricities (e > 2) the dependence is sub-linear and finally becomes independent of e for very large eccentricities (e > 30). These results imply that a precise account of the nanoparticle shape is required to quantify EFM data and obtain the dielectric constants of non-spherical dielectric nanoparticles. Experimental results obtained on polystyrene, silicon dioxide and aluminum oxide nanoparticles and on single viruses are used to illustrate the main findings.

  5. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    NASA Astrophysics Data System (ADS)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Arehart, A. R.; Ringel, S. A.

    2016-04-01

    The impact of proton irradiation on the threshold voltage (VT) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of VT was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 1014 cm-2. Silvaco Atlas simulations of VT shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different VT dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed VT shifts. The proton irradiation induced VT shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

  6. Emission mechanisms in Al-rich AlGaN/AlN quantum wells assessed by excitation power dependent photoluminescence spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwata, Yoshiya; Banal, Ryan G.; Ichikawa, Shuhei

    2015-02-21

    The optical properties of Al-rich AlGaN/AlN quantum wells are assessed by excitation-power-dependent time-integrated (TI) and time-resolved (TR) photoluminescence (PL) measurements. Two excitation sources, an optical parametric oscillator and the 4th harmonics of a Ti:sapphire laser, realize a wide range of excited carrier densities between 10{sup 12} and 10{sup 21 }cm{sup −3}. The emission mechanisms change from an exciton to an electron-hole plasma as the excitation power increases. Accordingly, the PL decay time is drastically reduced, and the integrated PL intensities increase in the following order: linearly, super-linearly, linearly again, and sub-linearly. The observed results are well accounted for by rate equationsmore » that consider the saturation effect of non-radiative recombination processes. Using both TIPL and TRPL measurements allows the density of non-radiative recombination centers, the internal quantum efficiency, and the radiative recombination coefficient to be reliably extracted.« less

  7. Heterogeneous activity causes a nonlinear increase in the group energy use of ant workers isolated from queen and brood.

    PubMed

    Ferral, Nolan; Holloway, Kyara; Li, Mingzhong; Yin, Zhaozheng; Hou, Chen

    2018-06-01

    Increasing evidence has shown that the energy use of ant colonies increases sublinearly with colony size so that large colonies consume less per capita energy than small colonies. It has been postulated that social environment (e.g., in the presence of queen and brood) is critical for the sublinear group energetics, and a few studies of ant workers isolated from queens and brood observed linear relationships between group energetics and size. In this paper, we hypothesize that the sublinear energetics arise from the heterogeneity of activity in ant groups, that is, large groups have relatively more inactive members than small groups. We further hypothesize that the energy use of ant worker groups that are allowed to move freely increases more slowly than the group size even if they are isolated from queen and brood. Previous studies only provided indirect evidence for these hypotheses due to technical difficulties. In this study, we applied the automated behavioral monitoring and respirometry simultaneously on isolated worker groups for long time periods, and analyzed the image with the state-of-the-art algorithms. Our results show that when activity was not confined, large groups had lower per capita energy use, a lower percentage of active members, and lower average walking speed than small groups; while locomotion was confined, however, the per capita energy use was a constant regardless of the group size. The quantitative analysis shows a direct link between variation in group energy use and the activity level of ant workers when isolated from queen and brood. © 2016 Institute of Zoology, Chinese Academy of Sciences.

  8. Nonlinear aeroservoelastic analysis of a controlled multiple-actuated-wing model with free-play

    NASA Astrophysics Data System (ADS)

    Huang, Rui; Hu, Haiyan; Zhao, Yonghui

    2013-10-01

    In this paper, the effects of structural nonlinearity due to free-play in both leading-edge and trailing-edge outboard control surfaces on the linear flutter control system are analyzed for an aeroelastic model of three-dimensional multiple-actuated-wing. The free-play nonlinearities in the control surfaces are modeled theoretically by using the fictitious mass approach. The nonlinear aeroelastic equations of the presented model can be divided into nine sub-linear modal-based aeroelastic equations according to the different combinations of deflections of the leading-edge and trailing-edge outboard control surfaces. The nonlinear aeroelastic responses can be computed based on these sub-linear aeroelastic systems. To demonstrate the effects of nonlinearity on the linear flutter control system, a single-input and single-output controller and a multi-input and multi-output controller are designed based on the unconstrained optimization techniques. The numerical results indicate that the free-play nonlinearity can lead to either limit cycle oscillations or divergent motions when the linear control system is implemented.

  9. Thermoluminescence of α-Al2O3:C,Mg annealed at 1200 °C

    NASA Astrophysics Data System (ADS)

    Kalita, J. M.; Chithambo, M. L.

    2018-05-01

    Stimulated luminescence in α-Al2O3:C,Mg has thus far been studied for samples annealed at temperature no higher than 900 °C as can be seen by an examination of the literature. We report the thermoluminescence (TL) features of α-Al2O3:C,Mg annealed at 1200 °C. A glow curve measured at 1 °C/s from the samples annealed at 1200 °C shows eight peaks at 54, 80, 102, 173, 238, 290, 330 and 387 °C. Kinetic analyses show that the peak at 54 °C follows general order kinetics (b = 1.3) whereas the rest follow first order kinetics. The values of the activation energy of the peaks are between 0.77 eV and 1.90 eV and the frequency factors are of the order of 1010-1014 s-1. The intensity of the peaks at 54, 80, 102 and 173 °C increase with heating rate whereas those of the peaks at 238 and 290 °C decrease with heating rate. The decrease of intensity of the peaks at 238 and 290 °C with heating rate is due to thermal quenching whereas the increase of intensity of the peaks with heating rate indicates an inverse thermal-quenching-like behaviour. Interestingly this behaviour is observed only after annealing at 1200 °C. The activation energy for thermal quenching as calculated using the peaks at 238 and 290 °C are (1.02 ± 0.16) eV and (1.33 ± 0.15) eV respectively. Regarding the dosimetric features, the dose response of the peaks at 54, 80 and 102 °C are sublinear within 1-10 Gy and the peak at 54 °C saturates above 6 Gy. In contrast, the response of the peak at 173 °C is sublinear with 1-4 Gy and superlinear between 4 and 10 Gy. The peaks are found to fade at different rates and the rate of fading is also affected by annealing.

  10. Scaling of average weighted shortest path and average receiving time on weighted expanded Koch networks

    NASA Astrophysics Data System (ADS)

    Wu, Zikai; Hou, Baoyu; Zhang, Hongjuan; Jin, Feng

    2014-04-01

    Deterministic network models have been attractive media for discussing dynamical processes' dependence on network structural features. On the other hand, the heterogeneity of weights affect dynamical processes taking place on networks. In this paper, we present a family of weighted expanded Koch networks based on Koch networks. They originate from a r-polygon, and each node of current generation produces m r-polygons including the node and whose weighted edges are scaled by factor w in subsequent evolutionary step. We derive closed-form expressions for average weighted shortest path length (AWSP). In large network, AWSP stays bounded with network order growing (0 < w < 1). Then, we focus on a special random walks and trapping issue on the networks. In more detail, we calculate exactly the average receiving time (ART). ART exhibits a sub-linear dependence on network order (0 < w < 1), which implies that nontrivial weighted expanded Koch networks are more efficient than un-weighted expanded Koch networks in receiving information. Besides, efficiency of receiving information at hub nodes is also dependent on parameters m and r. These findings may pave the way for controlling information transportation on general weighted networks.

  11. A New Ghost Cell/Level Set Method for Moving Boundary Problems: Application to Tumor Growth

    PubMed Central

    Macklin, Paul

    2011-01-01

    In this paper, we present a ghost cell/level set method for the evolution of interfaces whose normal velocity depend upon the solutions of linear and nonlinear quasi-steady reaction-diffusion equations with curvature-dependent boundary conditions. Our technique includes a ghost cell method that accurately discretizes normal derivative jump boundary conditions without smearing jumps in the tangential derivative; a new iterative method for solving linear and nonlinear quasi-steady reaction-diffusion equations; an adaptive discretization to compute the curvature and normal vectors; and a new discrete approximation to the Heaviside function. We present numerical examples that demonstrate better than 1.5-order convergence for problems where traditional ghost cell methods either fail to converge or attain at best sub-linear accuracy. We apply our techniques to a model of tumor growth in complex, heterogeneous tissues that consists of a nonlinear nutrient equation and a pressure equation with geometry-dependent jump boundary conditions. We simulate the growth of glioblastoma (an aggressive brain tumor) into a large, 1 cm square of brain tissue that includes heterogeneous nutrient delivery and varied biomechanical characteristics (white matter, gray matter, cerebrospinal fluid, and bone), and we observe growth morphologies that are highly dependent upon the variations of the tissue characteristics—an effect observed in real tumor growth. PMID:21331304

  12. Sublinear Upper Bounds for Stochastic Programs with Recourse. Revision.

    DTIC Science & Technology

    1987-06-01

    approximation procedures for (1.1) generally rely on discretizations of E (Huang, Ziemba , and Ben-Tal (1977), Kall and Stoyan (1982), Birge and Wets...Wright, Practical optimization (Academic Press, London and New York,1981). C.C. Huang, W. Ziemba , and A. Ben-Tal, "Bounds on the expectation of a con

  13. Thermoluminescence response of rare earth activated zinc lithium borate glass

    NASA Astrophysics Data System (ADS)

    Saidu, A.; Wagiran, H.; Saeed, M. A.; Obayes, H. K.; Bala, A.; Usman, F.

    2018-03-01

    New glasses of zinc lithium borate doped with terbium oxide were synthesized by high temperature solid-state reaction. The amorphous nature of the glasses was confirmed using x-ray diffraction analysis (XRD). Thermoluminescence (TL) response of pure zinc lithium borate (ZLB) and zinc lithium borate doped with terbium (ZLB: Tb) exposed to gamma radiation was measured and compared. There is significant enhancement in the TL yields of ZLB: Tb compared to that of pure ZLB. Effect of varying concentration of dopant (Tb4O7) on the TL response of zinc lithium borate was investigated. 0.3 mol% concentration of Tb exhibited strongest TL intensity. Thermoluminescence curve of the phosphor consist of single isolated peak. The TL response of the new materials to the exposed radiation is linear within 0.5-100 Gy range of dose with sublinearity at the lower region of the curve. High sensitivity was exhibited by the new amorphous materials. Reproducibility, thermal fading and energy response of the proposed TLD were investigated and shows remarkable result that made the phosphor suitable for radiation dosimetry.

  14. Self-attracting walk on heterogeneous networks

    NASA Astrophysics Data System (ADS)

    Kim, Kanghun; Kyoung, Jaegu; Lee, D.-S.

    2016-05-01

    Understanding human mobility in cyberspace becomes increasingly important in this information era. While human mobility, memory-dependent and subdiffusive, is well understood in Euclidean space, it remains elusive in random heterogeneous networks like the World Wide Web. Here we study the diffusion characteristics of self-attracting walks, in which a walker is more likely to move to the locations visited previously than to unvisited ones, on scale-free networks. Under strong attraction, the number of distinct visited nodes grows linearly in time with larger coefficients in more heterogeneous networks. More interestingly, crossovers to sublinear growths occur in strongly heterogeneous networks. To understand these phenomena, we investigate the characteristic volumes and topology of the cluster of visited nodes and find that the reinforced attraction to hubs results in expediting exploration first but delaying later, as characterized by the scaling exponents that we derive. Our findings and analysis method can be useful for understanding various diffusion processes mediated by human.

  15. Auger recombination in Dirac materials: A tangle of many-body effects

    NASA Astrophysics Data System (ADS)

    Alymov, Georgy; Vyurkov, Vladimir; Ryzhii, Victor; Satou, Akira; Svintsov, Dmitry

    2018-05-01

    The peculiar electron dispersion in Dirac materials makes lowest-order Auger processes prohibited or marginally prohibited by energy and momentum conservation laws. Thus, Auger recombination (AR) in these materials is very sensitive to many-body effects. We incorporate them at the level of the G W approximation into the nonequilibrium Green's functions approach to AR and study the role of dynamic screening, spectrum broadening, and renormalization in the case of weakly pumped undoped graphene. We find that incorrect treatment of many-body effects can lead to an order-of-magnitude error in the recombination rate. We show that the AR time depends weakly (sublinearly) on the background dielectric constant, which limits the possibility to control recombination by the choice of substrate. However, the AR time can be considerably prolonged by placing graphene under a metal gate or by introducing a band gap. With carrier cooling taken into account, our results comply with experiments on photoexcited graphene.

  16. Pressure-Dependent Photoluminescence Study of Wurtzite InP Nanowires.

    PubMed

    Chauvin, Nicolas; Mavel, Amaury; Patriarche, Gilles; Masenelli, Bruno; Gendry, Michel; Machon, Denis

    2016-05-11

    The elastic properties of InP nanowires are investigated by photoluminescence measurements under hydrostatic pressure at room temperature and experimentally deduced values of the linear pressure coefficients are obtained. The pressure-induced energy shift of the A and B transitions yields a linear pressure coefficient of αA = 88.2 ± 0.5 meV/GPa and αB = 89.3 ± 0.5 meV/GPa with a small sublinear term of βA = βB = -2.7 ± 0.2 meV/GPa(2). Effective hydrostatic deformation potentials of -6.12 ± 0.04 and -6.2 ± 0.04 eV are derived from the results for the A and B transitions, respectively. A decrease of the integrated intensity is observed above 0.5 GPa and is interpreted as a carrier transfer from the first to the second conduction band of the wurtzite InP.

  17. Role of hydrodynamic viscosity on phonon transport in suspended graphene

    NASA Astrophysics Data System (ADS)

    Li, Xun; Lee, Sangyeop

    2018-03-01

    When phonon transport is in the hydrodynamic regime, the thermal conductivity exhibits peculiar dependences on temperatures (T ) and sample widths (W ). These features were used in the past to experimentally confirm the hydrodynamic phonon transport in three-dimensional bulk materials. Suspended graphene was recently predicted to exhibit strong hydrodynamic features in thermal transport at much higher temperature than the three-dimensional bulk materials, but its experimental confirmation requires quantitative guidance by theory and simulation. Here we quantitatively predict those peculiar dependences using the Monte Carlo solution of the Peierls-Boltzmann equation with an ab initio full three-phonon scattering matrix. Thermal conductivity is found to increase as Tα where α ranges from 1.89 to 2.49 depending on a sample width at low temperatures, much larger than 1.68 of the ballistic case. The thermal conductivity has a width dependence of W1.17 at 100 K, clearly distinguished from the sublinear dependence of the ballistic-diffusive regime. These peculiar features are explained with a phonon viscous damping effect of the hydrodynamic regime. We derive an expression for the phonon hydrodynamic viscosity from the Peierls-Boltzmann equation, and discuss the fact that the phonon viscous damping explains well those peculiar dependences of thermal conductivity at 100 K. The phonon viscous damping still causes significant thermal resistance when a temperature is 300 K and a sample width is around 1 µm, even though the hydrodynamic regime is not dominant over other regimes at this condition.

  18. Thermoluminescent properties of some phosphor glasses based on aluminum oxide.

    PubMed

    El Mesady, I; Khaled, N; Hussein, A; El Samman, H; Alawsh, S

    2016-12-01

    The transparent thermoluminescent aluminum oxide-based glass of 15Al 2 O 3 -35P 2 O 5 -25CaO-25Na 2 CO 3 , abbreviated as APCN (all in mol%) doped with different concentrations of SiO 2 from 0.0-500 ppm was prepared using a conventional melt-quenching technique. The TL sensitivities of the prepared glasses were investigated at 3 Gy γ-dose using a 60 Co source and measured at a heating rate 10 C/sec. The highest TL intensity of the material doped with SiO 2 was found at a concentration of 500 ppm (APCNSi 5 ). Deconvolution of the glow curve from APCNSi 5 resulted in four peaks at about 161, 194, 237 and 293 C with a Figure Of Merit (FOM) of 1.28%. The APCNSi 5 specimen had the best dosimetric properties when compared with the other samples. Reproducibility, repeatability, dose-response curve and fading effect were checked for peak 3, which appeared at about 237 C. The results displayed that the APCNSi 5 glass system was a low-Z material (Z eff  ≈ 10), and had good reproducibility and good repeatability. Peak 3 showed good linearity over a dose range up to 20 Gy (R 2  = 0.999) and sublinearity behaviour was found. The signal from APCNSi 5 faded by about 11% after 2 days post irradiation, therefore it showed almost no significant loss. Such properties make the newly prepared glasses suitable for and highly recommended for use in γ-dosimeters. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. DISPLACEMENT CASCADE SIMULATION IN TUNGSTEN AT 1025 K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Setyawan, Wahyu; Nandipati, Giridhar; Roche, Kenneth J.

    2013-09-30

    Molecular dynamics simulation was employed to investigate the irradiation damage properties of bulk tungsten at 1025 K (0.25 melting temperature). A comprehensive data set of primary cascade damage was generated up to primary knock-on atom (PKA) energies 100 keV. The dependence of the number of surviving Frenkel pairs (NFP) on the PKA energy (E) exhibits three different characteristic domains presumably related to the different cascade morphologies that form. The low-energy regime < 0.2 keV is characterized by a hit-or-miss type of Frenkel pair (FP) production near the displacement threshold energy of 128 eV. The middle regime 0.3 – 30 keVmore » exhibits a sublinear dependence of log(NFP) vs log(E) associated with compact cascade morphology with a slope of 0.73. Above 30 keV, the cascade morphology consists of complex branches or interconnected damage regions. In this extended morphology, large interstitial clusters form from superposition of interstitials from nearby damage regions. Strong clustering above 30 keV results in a superlinear dependence of log(NFP) vs log(E) with a slope of 1.365. At 100 keV, an interstitial cluster of size 92 and a vacancy cluster of size 114 were observed.« less

  20. Information dynamics shape the sexual networks of Internet-mediated prostitution

    PubMed Central

    Rocha, Luis E. C.; Liljeros, Fredrik; Holme, Petter

    2010-01-01

    Like many other social phenomena, prostitution is increasingly coordinated over the Internet. The online behavior affects the offline activity; the reverse is also true. We investigated the reported sexual contacts between 6,624 anonymous escorts and 10,106 sex buyers extracted from an online community from its beginning and six years on. These sexual encounters were also graded and categorized (in terms of the type of sexual activities performed) by the buyers. From the temporal, bipartite network of posts, we found a full feedback loop in which high grades on previous posts affect the future commercial success of the sex worker, and vice versa. We also found a peculiar growth pattern in which the turnover of community members and sex workers causes a sublinear preferential attachment. There is, moreover, a strong geographic influence on network structure—the network is geographically clustered but still close to connected, the contacts consistent with the inverse-square law observed in trading patterns. We also found that the number of sellers scales sublinearly with city size, so this type of prostitution does not, comparatively speaking, benefit much from an increasing concentration of people. PMID:20231480

  1. Intensity dependence and transient dynamics of donor-acceptor pair recombination in ZnO thin films grown on (001) silicon

    NASA Astrophysics Data System (ADS)

    Guo, Bing; Qiu, Z. R.; Wong, K. S.

    2003-04-01

    We report room-temperature time-integrated and time-resolved photoluminescence (PL) measurements on a nominally undoped wurtzite ZnO thin film grown on (001) silicon. A linear and sublinear excitation intensity Iex dependence of the PL intensity were observed for the 379.48-nm exciton line and the weak broad green band (˜510 nm), respectively. The green luminescence was found to decay as hyperbolic t-1, and its peak energy was observed to increase nearly logarithmically with increased Iex. These results are in an excellent agreement with the tunnel-assisted donor-deep-acceptor pair (DAP) model so that its large blueshifts of about 25 meV per decade increase in Iex can be accounted for by the screening of the fluctuating impurity potential. Also, the 30-ps fast decay of the exciton emission was attributed to the rapid trapping of carriers at luminescent impurities, while the short lifetime of τ1/e=200 ps for the green luminescence may be due to an alternative trapping by deeper centers in the ZnO. Finally, singly ionized oxygen and zinc vacancies have been tentatively invoked to act as donor-deep-acceptor candidates for the DAP luminescence, respectively.

  2. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.

    2016-04-28

    The impact of proton irradiation on the threshold voltage (V{sub T}) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of V{sub T} was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 10{sup 14} cm{sup −2}. Silvaco Atlas simulations of V{sub T} shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different V{sub T} dependences on protonmore » irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed V{sub T} shifts. The proton irradiation induced V{sub T} shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.« less

  3. Monitoring exposure to acrylonitrile using adducts with N-terminal valine in hemoglobin.

    PubMed

    Osterman-Golkar, S M; MacNeela, J P; Turner, M J; Walker, V E; Swenberg, J A; Sumner, S J; Youtsey, N; Fennell, T R

    1994-12-01

    Human exposure to acrylonitrile (ACN), a carcinogen in rats, may occur in industrial settings, through waste water and tobacco smoke. ACN is an electrophilic compound and binds covalently to nucleophilic sites in macromolecules. Measurements of adducts with hemoglobin could be utilized for improved exposure assessments. In this study, a method for quantification of N-(2-cyanoethyl)valine (CEVal), the product of reaction of ACN with N-terminal valine in hemoglobin has been developed. The method is based on the N-alkyl Edman procedure, which involves derivatization of the globin with pentafluorophenyl isothiocyanate and gas chromatographic-mass spectrometric analysis of the resulting thiohydantoin. An internal standard was prepared by reacting valylglycylglycine with [2H3]ACN, spiked with [14C]ACN to a known sp. act. Levels of CEVal were measured in globin from rats exposed to 3-300 p.p.m. ACN in drinking water for 105 days and from humans (four smokers and four non-smokers). CEVal was detected at all exposure levels in the drinking water study. The relationship between adduct level and water concentration was linear at concentrations of 10 p.p.m. (corresponding to an average daily uptake of c. 0.74 mg ACN/kg body wt during the 65 days prior to sacrifice) and below, with a slope of 37.7 pmol CEVal/g globin/p.p.m. At higher concentrations, adduct levels increased sublinearly, indicating saturation of a metabolic process for elimination of ACN. Comparison of adduct formation with the estimated dose (mg/kg/day) of ACN indicated that at low dose (0-10 p.p.m.) CEVal = 0.508 x ACN dose + 0.048 and at high dose (35-300 p.p.m.) CEVal = 1.142 x ACN dose - 1.098. Globin from the smokers (10-20 cigarettes/day) contained about 90 pmol CEVal/g, whereas the adduct levels in globin from non-smokers were below the detection limit. The analytical sensitivity should be sufficient to allow monitoring of occupationally exposed workers at levels well below the current Occupational Safety and Health Administration standard of 2 p.p.m.

  4. The electrostatic persistence length of polymers beyond the OSF limit.

    PubMed

    Everaers, R; Milchev, A; Yamakov, V

    2002-05-01

    We use large-scale Monte Carlo simulations to test scaling theories for the electrostatic persistence length l(e) of isolated, uniformly charged polymers with Debye-Hückel intrachain interactions in the limit where the screening length kappa(-1) exceeds the intrinsic persistence length of the chains. Our simulations cover a significantly larger part of the parameter space than previous studies. We observe no significant deviations from the prediction l(e) proportional to kappa(-2) by Khokhlov and Khachaturian which is based on applying the Odijk-Skolnick-Fixman theories of electrostatic bending rigidity and electrostatically excluded volume to the stretched de Gennes-Pincus-Velasco-Brochard polyelectrolyte blob chain. A linear or sublinear dependence of the persistence length on the screening length can be ruled out. We show that previous results pointing into this direction are due to a combination of excluded-volume and finite chain length effects. The paper emphasizes the role of scaling arguments in the development of useful representations for experimental and simulation data.

  5. What information can frictional properties of polymer brushes tell us?

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenyu; Moxey, Mark; Morse, Andrew; Armes, Steven; Lewis, Andrew; Geoghegan, Mark; Leggett, Graham

    2013-03-01

    We have used friction force microscopy (FFM) to quantitatively examine surface grown zwitterionic polymer brushes: poly(2-(methacryloyloxy)ethyl phosphorylcholine) (PMPC), and to establish the correlation between its frictional behaviour to other intrinsic properties. In a good solvent, it was found that the coefficient of friction (μ) decreased with increasing film thickness. We conclude that the amount of bound solvent increases as the brush length increases, causing the osmotic pressure to increase and yielding a reduced tendency for the brush layer to deform under applied load. When measured in a series of alcohol/water mixtures, a significant increase in μ was observed for ethanol/water mixtures at a volume fraction of 90%. This is attributed to brush collapse due to co-nonsolvency, leading to loss of hydration of the brush chains and hence substantially reduced lubrication. We show that single asperity contact mechanics is strongly dependent on solvent quality. Friction-load relationship was found linear in methanol (good solvent), but sub-linear in water and ethanol (moderate solvent).

  6. Statistical description of the motion of dislocation kinks in a random field of impurities adsorbed by a dislocation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petukhov, B. V., E-mail: petukhov@ns.crys.ras.r

    2010-01-15

    A model has been proposed for describing the influence of impurities adsorbed by dislocation cores on the mobility of dislocation kinks in materials with a high crystalline relief (Peierls barriers). The delay time spectrum of kinks at statistical fluctuations of the impurity density has been calculated for a sufficiently high energy of interaction between impurities and dislocations when the migration potential is not reduced to a random Gaussian potential. It has been shown that fluctuations in the impurity distribution substantially change the character of the migration of dislocation kinks due to the slow decrease in the probability of long delaymore » times. The dependences of the position of the boundary of the dynamic phase transition to a sublinear drift of kinks x {proportional_to} t{sup {delta}} ({delta} {sigma} 1) and the characteristics of the anomalous mobility on the physical parameters (stress, impurity concentration, experimental temperature, etc.) have been calculated.« less

  7. Endpoint regularity of discrete multisublinear fractional maximal operators associated with [Formula: see text]-balls.

    PubMed

    Liu, Feng

    2018-01-01

    In this paper we investigate the endpoint regularity of the discrete m -sublinear fractional maximal operator associated with [Formula: see text]-balls, both in the centered and uncentered versions. We show that these operators map [Formula: see text] into [Formula: see text] boundedly and continuously. Here [Formula: see text] represents the set of functions of bounded variation defined on [Formula: see text].

  8. In vivo voltage-dependent influences on summation of synaptic potentials in neurons of the lateral nucleus of the amygdala

    PubMed Central

    Rosenkranz, J. Amiel

    2012-01-01

    The amygdala has a fundamental role in driving affective behaviors in response to sensory cues. To accomplish this, neurons of the lateral nucleus (LAT) must integrate a large number of synaptic inputs. A wide range of factors influence synaptic integration, including membrane potential, voltage-gated ion channels and GABAergic inhibition. However, little is known about how these factors modulate integration of synaptic inputs in LAT neurons in vivo. The purpose of this study was to determine the voltage-dependent factors that modify in vivo integration of synaptic inputs in the soma of LAT neurons. In vivo intracellular recordings from anesthetized rats were used to measure post-synaptic potentials (PSPs) and clusters of PSPs across a range of membrane potentials. These studies found that the relationship between membrane potential and PSP clusters was sublinear, due to a reduction of cluster amplitude and area at depolarized membrane potentials. In combination with intracellular delivery of pharmacological agents, it was found that the voltage-dependent suppression of PSP clusters was sensitive to tetraethylammonium (TEA), but not cesium or a blocker of fast GABAergic inhibition. These findings indicate that integration of PSPs in LAT neurons in vivo is strongly modified by somatic membrane potential, likely through voltage-dependent TEA-sensitive potassium channels. Conditions that lead to a shift in membrane potential, or a modulation of the number or function of these ion channels will lead to a more uniform capacity for integration across voltages, and perhaps greatly facilitate amygdala-dependent behaviors. PMID:22989917

  9. Scaling of Average Weighted Receiving Time on Double-Weighted Koch Networks

    NASA Astrophysics Data System (ADS)

    Dai, Meifeng; Ye, Dandan; Hou, Jie; Li, Xingyi

    2015-03-01

    In this paper, we introduce a model of the double-weighted Koch networks based on actual road networks depending on the two weight factors w,r ∈ (0, 1]. The double weights represent the capacity-flowing weight and the cost-traveling weight, respectively. Denote by wFij the capacity-flowing weight connecting the nodes i and j, and denote by wCij the cost-traveling weight connecting the nodes i and j. Let wFij be related to the weight factor w, and let wCij be related to the weight factor r. This paper assumes that the walker, at each step, starting from its current node, moves to any of its neighbors with probability proportional to the capacity-flowing weight of edge linking them. The weighted time for two adjacency nodes is the cost-traveling weight connecting the two nodes. We define the average weighted receiving time (AWRT) on the double-weighted Koch networks. The obtained result displays that in the large network, the AWRT grows as power-law function of the network order with the exponent, represented by θ(w,r) = ½ log2(1 + 3wr). We show that the AWRT exhibits a sublinear or linear dependence on network order. Thus, the double-weighted Koch networks are more efficient than classic Koch networks in receiving information.

  10. Multipartite entanglement gambling: The power of asymptotic state transformations assisted by a sublinear amount of quantum communication

    NASA Astrophysics Data System (ADS)

    Thapliyal, Ashish V.; Smolin, John A.

    2003-12-01

    Reversible state transformations under entanglement nonincreasing operations give rise to entanglement measures. It is well known that asymptotic local operations and classical communication (LOCC) are required to get a simple operational measure of bipartite pure state entanglement. For bipartite mixed states and multipartite pure states it is likely that a more powerful class of operations will be needed. To this end more powerful versions of state transformations (or reducibilities), namely, LOCCq (asymptotic LOCC with a sublinear amount of quantum communication) and CLOCC (asymptotic LOCC with catalysis) have been considered in the literature. In this paper we show that LOCCq state transformations are only as powerful as asymptotic LOCC state transformations for multipartite pure states. The basic tool we use is multipartite entanglement gambling: Any pure multipartite entangled state can be transformed to an Einstein-Podolsky-Rosen pair shared by some pair of parties and any irreducible m-party pure state (m⩾2) can be used to create any other state (pure or mixed) using LOCC. We consider applications of multipartite entanglement gambling to multipartite distillability and to characterizations of multipartite minimal entanglement generating sets. We briefly consider generalizations of this result to mixed states by defining the class of cat-distillable states, i.e., states from which cat states (|0⊗m>+|1⊗m>) may be distilled.

  11. Multipartite entanglement gambling: The power of asymptotic state transformations assisted by a sublinear amount of quantum communication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thapliyal, Ashish V.; Smolin, John A.; IBM Thomas J. Watson Research Center, Yorktown Heights, New York 10598

    2003-12-01

    Reversible state transformations under entanglement nonincreasing operations give rise to entanglement measures. It is well known that asymptotic local operations and classical communication (LOCC) are required to get a simple operational measure of bipartite pure state entanglement. For bipartite mixed states and multipartite pure states it is likely that a more powerful class of operations will be needed. To this end more powerful versions of state transformations (or reducibilities), namely, LOCCq (asymptotic LOCC with a sublinear amount of quantum communication) and CLOCC (asymptotic LOCC with catalysis) have been considered in the literature. In this paper we show that LOCCq statemore » transformations are only as powerful as asymptotic LOCC state transformations for multipartite pure states. The basic tool we use is multipartite entanglement gambling: Any pure multipartite entangled state can be transformed to an Einstein-Podolsky-Rosen pair shared by some pair of parties and any irreducible m-party pure state (m{>=}2) can be used to create any other state (pure or mixed) using LOCC. We consider applications of multipartite entanglement gambling to multipartite distillability and to characterizations of multipartite minimal entanglement generating sets. We briefly consider generalizations of this result to mixed states by defining the class of cat-distillable states, i.e., states from which cat states (vertical bar 0{sup xm}>+vertical bar 1{sup xm}>) may be distilled.« less

  12. Scaling of the Urban Water Footprint: An Analysis of 65 Mid- to Large-Sized U.S. Metropolitan Areas

    NASA Astrophysics Data System (ADS)

    Mahjabin, T.; Garcia, S.; Grady, C.; Mejia, A.

    2017-12-01

    Scaling laws have been shown to be relevant to a range of disciplines including biology, ecology, hydrology, and physics, among others. Recently, scaling was shown to be important for understanding and characterizing cities. For instance, it was found that urban infrastructure (water supply pipes and electrical wires) tends to scale sublinearly with city population, implying that large cities are more efficient. In this study, we explore the scaling of the water footprint of cities. The water footprint is a measure of water appropriation that considers both the direct and indirect (virtual) water use of a consumer or producer. Here we compute the water footprint of 65 mid- to large-sized U.S. metropolitan areas, accounting for direct and indirect water uses associated with agricultural and industrial commodities, and residential and commercial water uses. We find that the urban water footprint, computed as the sum of the water footprint of consumption and production, exhibits sublinear scaling with an exponent of 0.89. This suggests the possibility of large cities being more water-efficient than small ones. To further assess this result, we conduct additional analysis by accounting for international flows, and the effects of green water and city boundary definition on the scaling. The analysis confirms the scaling and provides additional insight about its interpretation.

  13. The factors influencing nonlinear characteristics of the short-circuit current in dye-sensitized solar cells investigated by a numerical model.

    PubMed

    Shi, Yushuai; Dong, Xiandui

    2013-06-24

    A numerical model for interpretation of the light-intensity-dependent nonlinear characteristics of the short-circuit current in dye-sensitized solar cells is suggested. The model is based on the continuity equation and includes the influences of the nongeminate recombination between electrons and electron acceptors in the electrolyte and the geminate recombination between electrons and oxidized dye molecules. The influences of the order and rate constant of the nongeminate recombination reaction, the light-absorption coefficient of the dye, the film thickness, the rate constant of geminate recombination, and the regeneration rate constant on the nonlinear characteristics of the short-circuit current are simulated and analyzed. It is proposed that superlinear and sublinear characteristics of the short-circuit current should be attributed to low electron-collection efficiency and low dye-regeneration efficiency, respectively. These results allow a deep understanding of the origin of the nonlinear characteristics of the short-circuit current in solar cells. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A Trotter-Suzuki approximation for Lie groups with applications to Hamiltonian simulation

    NASA Astrophysics Data System (ADS)

    Somma, Rolando D.

    2016-06-01

    We present a product formula to approximate the exponential of a skew-Hermitian operator that is a sum of generators of a Lie algebra. The number of terms in the product depends on the structure factors. When the generators have large norm with respect to the dimension of the Lie algebra, or when the norm of the effective operator resulting from nested commutators is less than the product of the norms, the number of terms in the product is significantly less than that obtained from well-known results. We apply our results to construct product formulas useful for the quantum simulation of some continuous-variable and bosonic physical systems, including systems whose potential is not quadratic. For many of these systems, we show that the number of terms in the product can be sublinear or even subpolynomial in the dimension of the relevant local Hilbert spaces, where such a dimension is usually determined by the energy scale of the problem. Our results emphasize the power of quantum computers for the simulation of various quantum systems.

  15. Multispeed Prethermalization in Quantum Spin Models with Power-Law Decaying Interactions

    NASA Astrophysics Data System (ADS)

    Frérot, Irénée; Naldesi, Piero; Roscilde, Tommaso

    2018-01-01

    The relaxation of uniform quantum systems with finite-range interactions after a quench is generically driven by the ballistic propagation of long-lived quasiparticle excitations triggered by a sufficiently small quench. Here we investigate the case of long-range (1 /rα) interactions for a d -dimensional lattice spin model with uniaxial symmetry, and show that, in the regime d <α

  16. Multispeed Prethermalization in Quantum Spin Models with Power-Law Decaying Interactions.

    PubMed

    Frérot, Irénée; Naldesi, Piero; Roscilde, Tommaso

    2018-02-02

    The relaxation of uniform quantum systems with finite-range interactions after a quench is generically driven by the ballistic propagation of long-lived quasiparticle excitations triggered by a sufficiently small quench. Here we investigate the case of long-range (1/r^{α}) interactions for a d-dimensional lattice spin model with uniaxial symmetry, and show that, in the regime d<α

  17. A Trotter-Suzuki approximation for Lie groups with applications to Hamiltonian simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Somma, Rolando D., E-mail: somma@lanl.gov

    2016-06-15

    We present a product formula to approximate the exponential of a skew-Hermitian operator that is a sum of generators of a Lie algebra. The number of terms in the product depends on the structure factors. When the generators have large norm with respect to the dimension of the Lie algebra, or when the norm of the effective operator resulting from nested commutators is less than the product of the norms, the number of terms in the product is significantly less than that obtained from well-known results. We apply our results to construct product formulas useful for the quantum simulation ofmore » some continuous-variable and bosonic physical systems, including systems whose potential is not quadratic. For many of these systems, we show that the number of terms in the product can be sublinear or even subpolynomial in the dimension of the relevant local Hilbert spaces, where such a dimension is usually determined by the energy scale of the problem. Our results emphasize the power of quantum computers for the simulation of various quantum systems.« less

  18. Pharmit: interactive exploration of chemical space.

    PubMed

    Sunseri, Jocelyn; Koes, David Ryan

    2016-07-08

    Pharmit (http://pharmit.csb.pitt.edu) provides an online, interactive environment for the virtual screening of large compound databases using pharmacophores, molecular shape and energy minimization. Users can import, create and edit virtual screening queries in an interactive browser-based interface. Queries are specified in terms of a pharmacophore, a spatial arrangement of the essential features of an interaction, and molecular shape. Search results can be further ranked and filtered using energy minimization. In addition to a number of pre-built databases of popular compound libraries, users may submit their own compound libraries for screening. Pharmit uses state-of-the-art sub-linear algorithms to provide interactive screening of millions of compounds. Queries typically take a few seconds to a few minutes depending on their complexity. This allows users to iteratively refine their search during a single session. The easy access to large chemical datasets provided by Pharmit simplifies and accelerates structure-based drug design. Pharmit is available under a dual BSD/GPL open-source license. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  19. A Trotter-Suzuki approximation for Lie groups with applications to Hamiltonian simulation

    DOE PAGES

    Somma, Rolando D.

    2016-06-01

    In this paper, we present a product formula to approximate the exponential of a skew-Hermitian operator that is a sum of generators of a Lie algebra. The number of terms in the product depends on the structure factors. When the generators have large norm with respect to the dimension of the Lie algebra, or when the norm of the effective operator resulting from nested commutators is less than the product of the norms, the number of terms in the product is significantly less than that obtained from well-known results. We apply our results to construct product formulas useful for themore » quantum simulation of some continuous-variable and bosonic physical systems, including systems whose potential is not quadratic. For many of these systems, we show that the number of terms in the product can be sublinear or even subpolynomial in the dimension of the relevant local Hilbert spaces, where such a dimension is usually determined by the energy scale of the problem. Our results emphasize the power of quantum computers for the simulation of various quantum systems.« less

  20. High-temperature performance of MoS2 thin-film transistors: Direct current and pulse current-voltage characteristics

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Rumyantsev, S. L.; Samnakay, R.; Shur, M. S.; Balandin, A. A.

    2015-02-01

    We report on fabrication of MoS2 thin-film transistors (TFTs) and experimental investigations of their high-temperature current-voltage characteristics. The measurements show that MoS2 devices remain functional to temperatures of at least as high as 500 K. The temperature increase results in decreased threshold voltage and mobility. The comparison of the direct current (DC) and pulse measurements shows that the direct current sub-linear and super-linear output characteristics of MoS2 thin-films devices result from the Joule heating and the interplay of the threshold voltage and mobility temperature dependences. At temperatures above 450 K, a kink in the drain current occurs at zero gate voltage irrespective of the threshold voltage value. This intriguing phenomenon, referred to as a "memory step," was attributed to the slow relaxation processes in thin films similar to those in graphene and electron glasses. The fabricated MoS2 thin-film transistors demonstrated stable operation after two months of aging. The obtained results suggest new applications for MoS2 thin-film transistors in extreme-temperature electronics and sensors.

  1. A model of urban scaling laws based on distance dependent interactions

    NASA Astrophysics Data System (ADS)

    Ribeiro, Fabiano L.; Meirelles, Joao; Ferreira, Fernando F.; Neto, Camilo Rodrigues

    2017-03-01

    Socio-economic related properties of a city grow faster than a linear relationship with the population, in a log-log plot, the so-called superlinear scaling. Conversely, the larger a city, the more efficient it is in the use of its infrastructure, leading to a sublinear scaling on these variables. In this work, we addressed a simple explanation for those scaling laws in cities based on the interaction range between the citizens and on the fractal properties of the cities. To this purpose, we introduced a measure of social potential which captured the influence of social interaction on the economic performance and the benefits of amenities in the case of infrastructure offered by the city. We assumed that the population density depends on the fractal dimension and on the distance-dependent interactions between individuals. The model suggests that when the city interacts as a whole, and not just as a set of isolated parts, there is improvement of the socio-economic indicators. Moreover, the bigger the interaction range between citizens and amenities, the bigger the improvement of the socio-economic indicators and the lower the infrastructure costs of the city. We addressed how public policies could take advantage of these properties to improve cities development, minimizing negative effects. Furthermore, the model predicts that the sum of the scaling exponents of social-economic and infrastructure variables are 2, as observed in the literature. Simulations with an agent-based model are confronted with the theoretical approach and they are compatible with the empirical evidences.

  2. A model of urban scaling laws based on distance dependent interactions.

    PubMed

    Ribeiro, Fabiano L; Meirelles, Joao; Ferreira, Fernando F; Neto, Camilo Rodrigues

    2017-03-01

    Socio-economic related properties of a city grow faster than a linear relationship with the population, in a log-log plot, the so-called superlinear scaling . Conversely, the larger a city, the more efficient it is in the use of its infrastructure, leading to a sublinear scaling on these variables. In this work, we addressed a simple explanation for those scaling laws in cities based on the interaction range between the citizens and on the fractal properties of the cities. To this purpose, we introduced a measure of social potential which captured the influence of social interaction on the economic performance and the benefits of amenities in the case of infrastructure offered by the city. We assumed that the population density depends on the fractal dimension and on the distance-dependent interactions between individuals. The model suggests that when the city interacts as a whole, and not just as a set of isolated parts, there is improvement of the socio-economic indicators. Moreover, the bigger the interaction range between citizens and amenities, the bigger the improvement of the socio-economic indicators and the lower the infrastructure costs of the city. We addressed how public policies could take advantage of these properties to improve cities development, minimizing negative effects. Furthermore, the model predicts that the sum of the scaling exponents of social-economic and infrastructure variables are 2, as observed in the literature. Simulations with an agent-based model are confronted with the theoretical approach and they are compatible with the empirical evidences.

  3. Influence of carbon on the thermoluminescence and optically stimulated luminescence of α-Al2O3:C crystals

    NASA Astrophysics Data System (ADS)

    Yang, Xin-Bo; Li, Hong-Jun; Bi, Qun-Yu; Cheng, Yan; Tang, Qiang; Xu, Jun

    2008-12-01

    α-Al2O3:C crystal shows excellent thermoluminescence (TL) and optically stimulated luminescence (OSL) properties but the real role carbon plays in this crystal is still not clearly understood so far. In this work, α-Al2O3:C crystal doping with different amounts of carbon were grown by the temperature gradient technique, and TL and OSL properties of as-grown crystals were investigated. Additionally, a mechanism was proposed to explain the role of carbon in forming the TL and OSL properties of α-Al2O3:C. TL and OSL intensities of as-grown crystals increase with the increasing amount of carbon doping in the crystal, but no shift is found in the glow peak location at 465 K. As the amount of carbon doping in the crystals decreases, OSL decay rate becomes faster. With the increase in heating rate, the integral TL response of as-grown crystals decreases and glow peak shifts to higher temperatures. TL response decrease rate increases with the increasing amount of carbon doping in the crystals. All the TL and OSL response curves of as-grown crystals show linear-sublinear-saturation characteristic, and OSL dose response exhibits higher sensitivity and wider linear dose range than that of TL. The crystal doping with 5000 ppm carbon shows the best dosimetric properties. Carbon plays the role of a dopant in α-Al2O3:C crystal and four-valent carbon anions replace the two-valent anions of oxygen during the crystal growth process, and large amounts of oxygen vacancies were formed, which corresponds to the high absorption coefficient of F and F+ centers in the crystals.

  4. Extrapolation of operators acting into quasi-Banach spaces

    NASA Astrophysics Data System (ADS)

    Lykov, K. V.

    2016-01-01

    Linear and sublinear operators acting from the scale of L_p spaces to a certain fixed quasinormed space are considered. It is shown how the extrapolation construction proposed by Jawerth and Milman at the end of 1980s can be used to extend a bounded action of an operator from the L_p scale to wider spaces. Theorems are proved which generalize Yano's extrapolation theorem to the case of a quasinormed target space. More precise results are obtained under additional conditions on the quasinorm. Bibliography: 35 titles.

  5. Stability versus neuronal specialization for STDP: long-tail weight distributions solve the dilemma.

    PubMed

    Gilson, Matthieu; Fukai, Tomoki

    2011-01-01

    Spike-timing-dependent plasticity (STDP) modifies the weight (or strength) of synaptic connections between neurons and is considered to be crucial for generating network structure. It has been observed in physiology that, in addition to spike timing, the weight update also depends on the current value of the weight. The functional implications of this feature are still largely unclear. Additive STDP gives rise to strong competition among synapses, but due to the absence of weight dependence, it requires hard boundaries to secure the stability of weight dynamics. Multiplicative STDP with linear weight dependence for depression ensures stability, but it lacks sufficiently strong competition required to obtain a clear synaptic specialization. A solution to this stability-versus-function dilemma can be found with an intermediate parametrization between additive and multiplicative STDP. Here we propose a novel solution to the dilemma, named log-STDP, whose key feature is a sublinear weight dependence for depression. Due to its specific weight dependence, this new model can produce significantly broad weight distributions with no hard upper bound, similar to those recently observed in experiments. Log-STDP induces graded competition between synapses, such that synapses receiving stronger input correlations are pushed further in the tail of (very) large weights. Strong weights are functionally important to enhance the neuronal response to synchronous spike volleys. Depending on the input configuration, multiple groups of correlated synaptic inputs exhibit either winner-share-all or winner-take-all behavior. When the configuration of input correlations changes, individual synapses quickly and robustly readapt to represent the new configuration. We also demonstrate the advantages of log-STDP for generating a stable structure of strong weights in a recurrently connected network. These properties of log-STDP are compared with those of previous models. Through long-tail weight distributions, log-STDP achieves both stable dynamics for and robust competition of synapses, which are crucial for spike-based information processing.

  6. Infrared Emitters and Photodetectors with InAsSb Bulk Active Region

    DTIC Science & Technology

    2013-04-29

    SLS) buffers on GaSb substrates [9]. By that time, 145 meV (A.= 8.6 J.lm) was reported to be the minimum energy gap for the bulk lnAsSb alloys at 77...substrate side (b) GaSb substrate thinned to 200iJm Figure 5. (a) The band diagram of the heterostructure with the undoped bulk InAsSb0.2 layer...shift of the EL energy peak compared to the PL peak at/, ... I 0 1-1m is explained by band filling under electrical injection. A sublinear

  7. A model of urban scaling laws based on distance dependent interactions

    PubMed Central

    Ribeiro, Fabiano L.; Meirelles, Joao; Ferreira, Fernando F.

    2017-01-01

    Socio-economic related properties of a city grow faster than a linear relationship with the population, in a log–log plot, the so-called superlinear scaling. Conversely, the larger a city, the more efficient it is in the use of its infrastructure, leading to a sublinear scaling on these variables. In this work, we addressed a simple explanation for those scaling laws in cities based on the interaction range between the citizens and on the fractal properties of the cities. To this purpose, we introduced a measure of social potential which captured the influence of social interaction on the economic performance and the benefits of amenities in the case of infrastructure offered by the city. We assumed that the population density depends on the fractal dimension and on the distance-dependent interactions between individuals. The model suggests that when the city interacts as a whole, and not just as a set of isolated parts, there is improvement of the socio-economic indicators. Moreover, the bigger the interaction range between citizens and amenities, the bigger the improvement of the socio-economic indicators and the lower the infrastructure costs of the city. We addressed how public policies could take advantage of these properties to improve cities development, minimizing negative effects. Furthermore, the model predicts that the sum of the scaling exponents of social-economic and infrastructure variables are 2, as observed in the literature. Simulations with an agent-based model are confronted with the theoretical approach and they are compatible with the empirical evidences. PMID:28405381

  8. Scaling laws and fluctuations in the statistics of word frequencies

    NASA Astrophysics Data System (ADS)

    Gerlach, Martin; Altmann, Eduardo G.

    2014-11-01

    In this paper, we combine statistical analysis of written texts and simple stochastic models to explain the appearance of scaling laws in the statistics of word frequencies. The average vocabulary of an ensemble of fixed-length texts is known to scale sublinearly with the total number of words (Heaps’ law). Analyzing the fluctuations around this average in three large databases (Google-ngram, English Wikipedia, and a collection of scientific articles), we find that the standard deviation scales linearly with the average (Taylor's law), in contrast to the prediction of decaying fluctuations obtained using simple sampling arguments. We explain both scaling laws (Heaps’ and Taylor) by modeling the usage of words using a Poisson process with a fat-tailed distribution of word frequencies (Zipf's law) and topic-dependent frequencies of individual words (as in topic models). Considering topical variations lead to quenched averages, turn the vocabulary size a non-self-averaging quantity, and explain the empirical observations. For the numerous practical applications relying on estimations of vocabulary size, our results show that uncertainties remain large even for long texts. We show how to account for these uncertainties in measurements of lexical richness of texts with different lengths.

  9. When immiscible becomes miscible-Methane in water at high pressures.

    PubMed

    Pruteanu, Ciprian G; Ackland, Graeme J; Poon, Wilson C K; Loveday, John S

    2017-08-01

    At low pressures, the solubility of gases in liquids is governed by Henry's law, which states that the saturated solubility of a gas in a liquid is proportional to the partial pressure of the gas. As the pressure increases, most gases depart from this ideal behavior in a sublinear fashion, leveling off at pressures in the 1- to 5-kbar (0.1 to 0.5 GPa) range with solubilities of less than 1 mole percent (mol %). This contrasts strikingly with the well-known marked increase in solubility of simple gases in water at high temperature associated with the critical point (647 K and 212 bar). The solubility of the smallest hydrocarbon, the simple gas methane, in water under a range of pressure and temperature is of widespread importance, because it is a paradigmatic hydrophobe and occurs widely in terrestrial and extraterrestrial geology. We report measurements up to 3.5 GPa of the pressure dependence of the solubility of methane in water at 100°C-well below the latter's critical temperature. Our results reveal a marked increase in solubility between 1 and 2 GPa, leading to a state above 2 GPa where the maximum solubility of methane in water exceeds 35 mol %.

  10. Acetylcholine-induced current in perfused rat myoballs

    PubMed Central

    1980-01-01

    Spherical "myoballs" were grown under tissue culture conditions from striated muscle of neonatal rat thighs. The myoballs were examined electrophysiologically with a suction pipette which was used to pass current and perfuse internally. A microelectrode was used to record membrane potential. Experiments were performed with approximately symmetrical (intracellular and extracellular) sodium aspartate solutions. The resting potential, acetylcholine (ACh) reversal potential, and sodium channel reversal potential were all approximately 0 mV. ACh-induced currents were examined by use of both voltage jumps and voltage ramps in the presence of iontophoretically applied agonist. The voltage-jump relaxations had a single exponential time-course. The time constant, tau, was exponentially related to membrane potential, increasing e-fold for 81 mV hyperpolarization. The equilibrium current- voltage relationship was also approximately exponential, from -120 to +81 mV, increasing e-fold for 104 mV hyperpolarization. The data are consistent with a first-order gating process in which the channel opening rate constant is slightly voltage dependent. The instantaneous current-voltage relationship was sublinear in the hyperpolarizing direction. Several models are discussed which can account for the nonlinearity. Evidence is presented that the "selectivity filter" for the ACh channel is located near the intracellular membrane surface. PMID:7381423

  11. On the existence of a solution to a quasilinear elliptic system of the Lane, Emden and Fowler type

    NASA Astrophysics Data System (ADS)

    Covei, Dragoş-Pǎtru

    2012-11-01

    In this article, we give an algorithm to obtain the existence of a solution for a quasilinear elliptic system. Our result is new and is based on a recent work of [R.J. Biezuner, J. Brown, G. Ercole and E.M. Martins, Computing the first eigenpair of the p-Laplacian via inverse iteration of sublinear supersolutions, J. Sci. Computation, 2011]. Such problems appear in boundary layer phenomena for viscous fluids, the equilibrium configuration of mass in a spherical cloud of gas, thermal explosion as well as in others applications.

  12. Iterated function systems for DNA replication

    NASA Astrophysics Data System (ADS)

    Gaspard, Pierre

    2017-10-01

    The kinetic equations of DNA replication are shown to be exactly solved in terms of iterated function systems, running along the template sequence and giving the statistical properties of the copy sequences, as well as the kinetic and thermodynamic properties of the replication process. With this method, different effects due to sequence heterogeneity can be studied, in particular, a transition between linear and sublinear growths in time of the copies, and a transition between continuous and fractal distributions of the local velocities of the DNA polymerase along the template. The method is applied to the human mitochondrial DNA polymerase γ without and with exonuclease proofreading.

  13. Impact of lithosphere rheology on the dynamic topography

    NASA Astrophysics Data System (ADS)

    Burov, Evgueni; Gerya, Taras; Koptev, Alexander

    2014-05-01

    Dynamic topography is a key observable signature of the Earth's and planetary (e.g. Venus) mantle dynamics. In general view, it reflects complex mantle flow patterns, and hence is supposed to correlate at different extent with seismic tomography, SKS fast orientations, geodetic velocity fields and geoid anomalies. However, identification of dynamic topography had no systematic success, specifically in the Earth's continents. Here we argue that lithosphere rheology, in particular, rheological stratification of continents, results in modulation of dynamic topography, converting commonly expected long-wavelength/small amplitude undulations into short-wavelength surface undulations with wide amplitude spectrum, superimposed onto "tectonic" topography. These ideas are explored in 3D using unprecedentedly high resolution numerical experiments (grid step size 2-3 km for 1500x1500x600 km computational area) incorporating realistic rheologically stratified lithosphere. Such high resolution is actually needed to resolve small-scale crustal faulting and inter-layer coupling/uncoupling that shape surface topography. The results reveal strikingly discordant, counterintuitive features of 3D dynamic topography, going far beyond the inferences from previous models. In particular, even weak anisotropic tectonic stress field results both in large-scale small-amplitude dynamic topography and in strongly anisotropic short-wavelength (at least in one direction) dynamic topography with wide amplitude range (from 100 to 2000-3000 m), including basins and ranges and large-scale linear normal and strike-slip faults. Even very slightly pre-stressed strong lithosphere yields and localizes deformation much easier , than un-prestressed one, in response to plume impact and mantle flow. The results shed new light on the importance of lithosphere rheology and active role of lithosphere in mantle-lithosphere interactions as well as on the role of mantle flow and far-field stresses in tectonic-scale deformation. We show, for example, that crustal fault patterns initiated by plume impact are rapidly re-organized in sub-linear rifts and spreading centers, which orientation is largely dictated (e.g., perpendicular to) by the direction of the tectonic far-field stress field, as well as the plume-head material soon starts to flow along the sub-linear rifted shear zones in crustal and mantle lithosphere further amplifying their development. The final surface deformation and mantle flow patterns rapidly loose the initial axisymmetric character and take elongated sub-linear shapes whereas brittle deformation at surface is amplified and stabilized by coherent flow of mantle/plume-head material from below. These "tectonically" looking dynamic topography patterns are quite different from those expected from conventional models as well as from those directly observed, for example, on Venus where plume-lithosphere interactions produce only axisymmetric coronae domal-shaped features with radiating extensional rifts, suggesting that the Venusian lithosphere is rheologically too weak , and its crust is too thin, to produce any significant impact on the dynamic topography.

  14. Dynamics of the tug-of-war model for cellular transport

    NASA Astrophysics Data System (ADS)

    Zhang, Yunxin; Fisher, Michael E.

    2010-07-01

    The transport of organelles and other cargoes in living cells has been described by a kinetic tug-of-war model advanced by Müller, Klumpp, and Lipowsky, in which, as a function of time, t , a team of n+(t)=0,1,⋯,N+ molecular motors may attach a cargo to a filamentous track and pull it towards the plus end in competition with n-(t)=0,1,⋯,N- motors that pull towards the opposite end. In recent work [Y. Zhang, Phys. Rev. E 79, 061918 (2009)10.1103/PhysRevE.79.061918] this model was analyzed for N+,N-≫1 , establishing the existence, depending on the motor parameters and the ratio ν=N+/N- , of system states with either one, two, or three distinct stable stationary modes of motion. Here, adopting a theoretical perspective, we study the parametric and ν dependence of the transitions between these mono-, bi-, or tristable system states and examine their associated trajectories and domains of attraction in the flow space, (n+,n-) , of the attached motor numbers. Various sequences of winning, losing, and “stalemate” or close-to-motionless modes are uncovered. When, as realistic, N+ and N- are of order 2 to 10, fluctuations will move the system from one of two or three modes of motion to another mode. An analysis of the associated probability fluxes demonstrates that the mean time between mode-to-mode transitions increases exponentially with N+ and N- . The overall stall force, i.e., the externally imposed load under which the mean cargo velocity vanishes, is similarly elucidated and shown to vary strongly but sublinearly with N+ and N- , as well as depending in a less than transparent manner on other model parameters beyond the stall forces of the individual + and - motors.

  15. Synergistic Anion-(π) n-π Catalysis on π-Stacked Foldamers.

    PubMed

    Bornhof, Anna-Bea; Bauzá, Antonio; Aster, Alexander; Pupier, Marion; Frontera, Antonio; Vauthey, Eric; Sakai, Naomi; Matile, Stefan

    2018-04-11

    In this report, we demonstrate that synergistic effects between π-π stacking and anion-π interactions in π-stacked foldamers provide access to unprecedented catalytic activity. To elaborate on anion-(π) n -π catalysis, we have designed, synthesized and evaluated a series of novel covalent oligomers with up to four face-to-face stacked naphthalenediimides (NDIs). NMR analysis including DOSY confirms folding into π stacks, cyclic voltammetry, steady-state and transient absorption spectroscopy the electronic communication within the π stacks. Catalytic activity, assessed by chemoselective catalysis of the intrinsically disfavored but biologically relevant addition reaction of malonate half thioesters to enolate acceptors, increases linearly with the length of the stacks to reach values that are otherwise beyond reach. This linear increase violates the sublinear power laws of oligomer chemistry. The comparison of catalytic activity with ratiometric changes in absorption and decreasing energy of the LUMO thus results in superlinearity, that is synergistic amplification of anion-π catalysis by remote control over the entire stack. In computational models, increasing length of the π-stacked foldamers correlates sublinearly with changes in surface potentials, chloride binding energies, and the distances between chloride and π surface and within the π stack. Computational evidence is presented that the selective acceleration of disfavored but relevant enolate chemistry by anion-π catalysis indeed originates from the discrimination of planar and bent tautomers with delocalized and localized charges, respectively, on π-acidic surfaces. Computed binding energies of keto and enol intermediates of the addition reaction as well as their difference increase with increasing length of the π stack and thus reflect experimental trends correctly. These results demonstrate that anion-(π) n -π interactions exist and matter, ready for use as a unique new tool in catalysis and beyond.

  16. Emergence of social structures via preferential selection

    NASA Astrophysics Data System (ADS)

    Lipowski, Adam; Lipowska, Dorota; Ferreira, Antonio Luis

    2014-09-01

    We examine a weighted-network multiagent model with preferential selection such that agents choose partners with probability p (w), where w is the number of their past selections. When p (w) increases sublinearly with the number of past selections [p(w)˜wα,α<1], agents develop a uniform preference for all other agents. At α =1, this state loses stability and more complex structures form. For a superlinear increase (α>1), strong heterogeneities emerge and agents make selections mainly within small and sometimes asymmetric clusters. Even in a few-agent case, the formation of such clusters resembles phase transitions with spontaneous symmetry breaking.

  17. Cortical Double-Opponent Cells in Color Perception: Perceptual Scaling and Chromatic Visual Evoked Potentials.

    PubMed

    Nunez, Valerie; Shapley, Robert M; Gordon, James

    2018-01-01

    In the early visual cortex V1, there are currently only two known neural substrates for color perception: single-opponent and double-opponent cells. Our aim was to explore the relative contributions of these neurons to color perception. We measured the perceptual scaling of color saturation for equiluminant color checkerboard patterns (designed to stimulate double-opponent neurons preferentially) and uniformly colored squares (designed to stimulate only single-opponent neurons) at several cone contrasts. The spatially integrative responses of single-opponent neurons would produce the same response magnitude for checkerboards as for uniform squares of the same space-averaged cone contrast. However, perceived saturation of color checkerboards was higher than for the corresponding squares. The perceptual results therefore imply that double-opponent cells are involved in color perception of patterns. We also measured the chromatic visual evoked potential (cVEP) produced by the same stimuli; checkerboard cVEPs were much larger than those for corresponding squares, implying that double-opponent cells also contribute to the cVEP response. The total Fourier power of the cVEP grew sublinearly with cone contrast. However, the 6-Hz Fourier component's power grew linearly with contrast-like saturation perception. This may also indicate that cortical coding of color depends on response dynamics.

  18. Structure of guar in solutions of H{sub 2}O and D{sub 2}O: An ultra-small-angle light-scattering study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gittings, M.R.; Cipelletti, L.; Trappe, V.

    2000-05-11

    The authors examine the structure of guar as a function of concentration in both H{sub 2}O and D{sub 2}O using several different scattering techniques. The range of scattering vectors spans 5 decades (143 cm{sup {minus}1} < q < 10.3 x 10{sup 6} cm{sup {minus}1}), providing insight into the supramolecular and local organization of the chains. This allows direct characterization of the large-scale aggregate structure of the guar, which can be on the order of 100 {micro}m. The aggregates are most likely loosely interconnected with single chains and other aggregates, and the structure and organization are critical in determining solution viscoelasticmore » properties. The solubility is poorer in D{sub 2}O as evidenced by larger aggregates, higher scattering intensities, a slightly higher fractal dimension, and a sublinear concentration dependence of the intensity. Aggregates were found in dilute neutral guar solutions as well as in cationic guar solutions (in H{sub 2}O), whether screened or unscreened. The presence of aggregates at all concentrations for neutral and charged guar indicates the difficulty in determining a molecular weight of the guar molecule.« less

  19. Cortical Double-Opponent Cells in Color Perception: Perceptual Scaling and Chromatic Visual Evoked Potentials

    PubMed Central

    Shapley, Robert M.; Gordon, James

    2018-01-01

    In the early visual cortex V1, there are currently only two known neural substrates for color perception: single-opponent and double-opponent cells. Our aim was to explore the relative contributions of these neurons to color perception. We measured the perceptual scaling of color saturation for equiluminant color checkerboard patterns (designed to stimulate double-opponent neurons preferentially) and uniformly colored squares (designed to stimulate only single-opponent neurons) at several cone contrasts. The spatially integrative responses of single-opponent neurons would produce the same response magnitude for checkerboards as for uniform squares of the same space-averaged cone contrast. However, perceived saturation of color checkerboards was higher than for the corresponding squares. The perceptual results therefore imply that double-opponent cells are involved in color perception of patterns. We also measured the chromatic visual evoked potential (cVEP) produced by the same stimuli; checkerboard cVEPs were much larger than those for corresponding squares, implying that double-opponent cells also contribute to the cVEP response. The total Fourier power of the cVEP grew sublinearly with cone contrast. However, the 6-Hz Fourier component’s power grew linearly with contrast-like saturation perception. This may also indicate that cortical coding of color depends on response dynamics. PMID:29375753

  20. Efficient probabilistic inference in generic neural networks trained with non-probabilistic feedback.

    PubMed

    Orhan, A Emin; Ma, Wei Ji

    2017-07-26

    Animals perform near-optimal probabilistic inference in a wide range of psychophysical tasks. Probabilistic inference requires trial-to-trial representation of the uncertainties associated with task variables and subsequent use of this representation. Previous work has implemented such computations using neural networks with hand-crafted and task-dependent operations. We show that generic neural networks trained with a simple error-based learning rule perform near-optimal probabilistic inference in nine common psychophysical tasks. In a probabilistic categorization task, error-based learning in a generic network simultaneously explains a monkey's learning curve and the evolution of qualitative aspects of its choice behavior. In all tasks, the number of neurons required for a given level of performance grows sublinearly with the input population size, a substantial improvement on previous implementations of probabilistic inference. The trained networks develop a novel sparsity-based probabilistic population code. Our results suggest that probabilistic inference emerges naturally in generic neural networks trained with error-based learning rules.Behavioural tasks often require probability distributions to be inferred about task specific variables. Here, the authors demonstrate that generic neural networks can be trained using a simple error-based learning rule to perform such probabilistic computations efficiently without any need for task specific operations.

  1. V-I characteristics of X-ray conductivity and UV photoconductivity of ZnSe crystals

    NASA Astrophysics Data System (ADS)

    Degoda, V. Ya.; Alizadeh, M.; Kovalenko, N. O.; Pavlova, N. Yu.

    2018-02-01

    This article outlines the resulting experimental V-I curves for high resistance ZnSe single crystals at temperatures of 8, 85, 295, and 420 K under three intensities of X-ray and UV excitations (hvUV > Eg). This paper considers the major factors that affect the nonlinearity in the V-I curves of high resistance ZnSe. We observe superlinear dependences at low temperatures, shifting to sublinear at room temperature and above. However, at all temperatures, we have initial linear areas of V-I curves. Using the initial linear areas of these characteristics, we obtained the lifetime values of free electrons and their mobility. The comparison of the conductivity values of X-ray and UV excitations made it possible to reveal the fact that most of the electron-hole pairs recombine in the local generation area, creating a scintillation pulse, while not participating in the conductivity. When analyzing the nonlinearity of the V-I curve, two new processes were considered in the first approximation: an increase in the average thermal velocity of electrons under the action of the electric field and the selectivity of the velocity direction of the electron upon delocalization from the traps under the Poole-Frenkel effect. It is assumed that the observed nonlinearity is due to the photoinduced contact difference in potentials.

  2. Aircraft- and ground-based assessment of the CCN-AOD relationship and implications on model analysis of ACI and underlying aerosol processes

    NASA Astrophysics Data System (ADS)

    Shinozuka, Y.; Clarke, A. D.; Nenes, A.; Lathem, T. L.; Redemann, J.; Jefferson, A.; Wood, R.

    2014-12-01

    Contrary to common assumptions in satellite-based modeling of aerosol-cloud interactions, ∂logCCN/∂logAOD is less than unity, i.e., the number concentration of cloud condensation nuclei (CCN) less than doubles as aerosol optical depth (AOD) doubles. This can be explained by omnipresent aerosol processes. Condensation, coagulation and cloud processing, for example, generally make particles scatter more light while hardly increasing their number. This paper reports on the relationship in local air masses between CCN concentration, aerosol size distribution and light extinction observed from aircraft and the ground at diverse locations. The CCN-to-local-extinction relationship, when averaged over ~1 km distance and sorted by the wavelength dependence of extinction, varies approximately by a factor of 2, reflecting the variability in aerosol intensive properties. This, together with retrieval uncertainties and the variability in aerosol spatio-temporal distribution and hygroscopic growth, challenges satellite-based CCN estimates. However, the large differences in estimated CCN may correspond to a considerably lower uncertainty in cloud drop number concentration (CDNC), given the sublinear response of CDNC to CCN. Overall, our findings from airborne and ground-based observations call for model-based reexamination of aerosol-cloud interactions and underlying aerosol processes.

  3. Kennicutt-Schmidt Relation Variety and Star-forming Cloud Fraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morokuma-Matsui, Kana; Muraoka, Kazuyuki, E-mail: kana.matsui@nao.ac.jp

    2017-03-10

    The observationally derived Kennicutt-Schmidt (KS) relation slopes differ from study to study, ranging from sublinear to superlinear. We investigate the KS-relation variety (slope and normalization) as a function of integrated intensity ratio, R {sub 31} = CO( J = 3–2)/CO( J = 1–0) using spatially resolved CO( J = 1–0), CO( J = 3–2), H i, H α, and 24 μ m data of three nearby spiral galaxies (NGC 3627, NGC 5055, and M83). We find that (1) the slopes for each subsample with a fixed R {sub 31} are shallower, but the slope for all data sets combined becomesmore » steeper, (2) normalizations for high R {sub 31} subsamples tend to be high, (3) R {sub 31} correlates with star formation efficiency, therefore the KS relation depends on the distribution in R {sub 31}–Σ{sub gas} space of the samples: no Σ{sub gas} dependence of R {sub 31} results in a linear slope of the KS relation, whereas a positive correlation between Σ{sub gas} and R {sub 31} results in a superlinear slope of the KS relation, and (4) R {sub 31}–Σ{sub gas} distributions are different from galaxy to galaxy and within a galaxy: galaxies with prominent galactic structure tend to have large R {sub 31} and Σ{sub gas}. Our results suggest that the formation efficiency of a star-forming cloud from molecular gas is different among galaxies as well as within a galaxy, and it is one of the key factors inducing the variety in galactic KS relation.« less

  4. Psychosis induced by the interaction between disulfiram and methylphenidate may be dose dependent.

    PubMed

    Grau-López, Lara; Roncero, Carlos; Navarro, Maria C; Casas, Miquel

    2012-01-01

    There are few studies describing psychiatric symptoms occurring when methylphenidate and disulfiram are used together. The authors report a case of disulfiram and methylphenidate interaction in which psychotic symptoms could be dose dependent. The patient, diagnosed of alcohol and cocaine dependence and attention deficit hyperactivity disorder (ADHD), started treatment with methylphenidate increasing doses and disulfiram 250 mg/day over 4 weeks. During the first 2 weeks at doses of 36 mg/day of methylphenidate and maintaining disulfiram, side effects were not observed. However, by increasing to 54 mg/day, psychotic symptoms were detected. The authors reported that the effects are dose dependent. This is the first report about dose-dependent side effects in substance use disorder with ADHD.

  5. Micronucleus induction in Vicia faba roots. Part 1. Absence of dose-rate, fractionation, and oxygen effect at low doses of low LET radiations.

    PubMed

    Marshall, I; Bianchi, M

    1983-08-01

    Micronucleus indication in Vicia faba roots has been evaluated after irradiation with 60Co gamma-rays. The dependence of the damage on dose, dose rate, fractionation, and oxygen has been studied. The best fit to the experimental data in the dose region between 7 and 190 cGy is represented, for single-dose exposures, by a linear + quadratic relationship. In the low-dose region, between 7 and 20 cGy, where the linear dose dependence is dominant, no dose-rate, fractionation, or oxygen effect could be observed. These effects were, however, present in the high-dose region, where the quadratic dependence is dominant.

  6. Continuing evaluation of bipolar linear devices for total dose bias dependency and ELDRS effects

    NASA Technical Reports Server (NTRS)

    McClure, Steven S.; Gorelick, Jerry L.; Yui, Candice; Rax, Bernard G.; Wiedeman, Michael D.

    2003-01-01

    We present results of continuing efforts to evaluate total dose bias dependency and ELDRS effects in bipolar linear microcircuits. Several devices were evaluated, each exhibiting moderate to significant bias and/or dose rate dependency.

  7. Field-size dependence of doses of therapeutic carbon beams.

    PubMed

    Kusano, Yohsuke; Kanai, Tatsuaki; Yonai, Shunsuke; Komori, Masataka; Ikeda, Noritoshi; Tachikawa, Yuji; Ito, Atsushi; Uchida, Hirohisa

    2007-10-01

    To estimate the physical dose at the center of spread-out Bragg peaks (SOBP) for various conditions of the irradiation system, a semiempirical approach was applied. The dose at the center of the SOBP depends on the field size because of large-angle scattering particles in the water phantom. For a small field of 5 x 5 cm2, the dose was reduced to 99.2%, 97.5%, and 96.5% of the dose used for the open field in the case of 290, 350, and 400 MeV/n carbon beams, respectively. Based on the three-Gaussian form of the lateral dose distributions of the carbon pencil beam, which has previously been shown to be effective for describing scattered carbon beams, we reconstructed the dose distributions of the SOBP beam. The reconstructed lateral dose distribution reproduced the measured lateral dose distributions very well. The field-size dependencies calculated using the reconstructed lateral dose distribution of the therapeutic carbon beam agreed with the measured dose dependency very well. The reconstructed beam was also used for irregularly shaped fields. The resultant dose distribution agreed with the measured dose distribution. The reconstructed beams were found to be applicable to the treatment-planning system.

  8. Enhanced damage resistance and novel defect structure of CrFeCoNi under in situ electron irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Mo -Rigen; Wang, Shuai; Jin, Ke

    Defect production and growth in CrFeCoNi, a single-phase concentrated solid solution alloy, is characterized using in situ electron irradiation inside a transmission electron microscope operated at 400–1250 kV and 400 °C. All observed defects are interstitial-type, either elliptical Frank loops or polygonal (mostly rhombus) perfect loops. Both forms of loops in CrFeCoNi exhibit a sublinear power law of growth that is > 40 times slower than the linear defect growth in pure Ni. Lastly, this result shows how compositional complexity impacts the production of Frenkel pairs and the agglomeration of interstitials into loops, and, thus, enhances the radiation tolerance.

  9. InP electroluminescence as a tool to directly monitor carrier leakage in InGaAsP/InP buried heterostructure lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, M.B.; Brody, E.; Sowell, B.

    1987-12-15

    Direct measurements of homojunction and heterojunction carrier leakage currents in InGaAsP/InP buried heterostructure lasers have been made by monitoring the electroluminescence (EL) at 0.96 ..mu..m in the InP confinement layers. These EL measurements show directly, for the first time, a correlation between homojunction leakage currents and the sublinearity in the 1.3-..mu..m light output-current characteristic. The observed decrease in the 0.96-..mu..m intensity with increasing p-dopant concentration is a direct confirmation that heterojunction leakage is reduced when the doping level in the p-InP confinement layer is increased.

  10. Quasiparticle renormalization in ABC graphene trilayers

    NASA Astrophysics Data System (ADS)

    Dou, Xu; Jaefari, Akbar; Barlas, Yafis; Uchoa, Bruno

    2015-03-01

    We investigate the effect of electron-electron interactions in ABC stacked graphene trilayers. In the gapless regime, we show that the self-energy corrections lead to the renormalization of the dynamical exponent z = 3 +α1 / N , with α1 ~ 0 . 52 and N is the number of fermionic species. Although the quasiparticle residue is suppressed near the neutrality point, the lifetime has a sublinear scaling with the energy and the quasiparticles are well defined even at zero energy. We calculate the renormalization of a variety of physical observables, which can be directly measured in experiments. X.D., A.J., and B.U. acknowledge University of Oklahoma for support. B.U. acknowledges NSF Career Grant No. DMR-1352604 for partial support.

  11. Enhanced damage resistance and novel defect structure of CrFeCoNi under in situ electron irradiation

    DOE PAGES

    He, Mo -Rigen; Wang, Shuai; Jin, Ke; ...

    2016-07-25

    Defect production and growth in CrFeCoNi, a single-phase concentrated solid solution alloy, is characterized using in situ electron irradiation inside a transmission electron microscope operated at 400–1250 kV and 400 °C. All observed defects are interstitial-type, either elliptical Frank loops or polygonal (mostly rhombus) perfect loops. Both forms of loops in CrFeCoNi exhibit a sublinear power law of growth that is > 40 times slower than the linear defect growth in pure Ni. Lastly, this result shows how compositional complexity impacts the production of Frenkel pairs and the agglomeration of interstitials into loops, and, thus, enhances the radiation tolerance.

  12. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    PubMed

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  13. Leuco-crystal-violet micelle gel dosimeters: Component effects on dose-rate dependence

    NASA Astrophysics Data System (ADS)

    Xie, J. C.; Katz, E. A. B.; Alexander, K. M.; Schreiner, L. J.; McAuley, K. B.

    2017-05-01

    Designed experiments were performed to produce empirical models for the dose sensitivity, initial absorbance, and dose-rate dependence respectively for leucocrystal violet (LCV) micelle gel dosimeters containing cetyltrimethylammonium bromide (CTAB) and 2,2,2-trichloroethanol (TCE). Previous gels of this type showed dose-rate dependent behaviour, producing an ˜18% increase in dose sensitivity between dose rates of 100 and 600 cGy min-1. Our models predict that the dose rate dependence can be reduced by increasing the concentration of TCE, CTAB and LCV. Increasing concentrations of LCV and CTAB produces a significant increase in dose sensitivity with a corresponding increase in initial absorbance. An optimization procedure was used to determine a nearly dose-rate independent gel which maintained high sensitivity and low initial absorbance. This gel which contains 33 mM CTAB, 1.25 mM LCV, and 96 mM TCE in 25 mM trichloroacetic acid and 4 wt% gelatin showed an increase in dose sensitivity of only 4% between dose rates of 100 and 600 cGy min-1, and provides an 80% greater dose sensitivity compared to Jordan’s standard gels with similar initial absorbance.

  14. Dependence of pentobarbital kinetics upon the dose of the drug and its pharmacodynamic effects.

    PubMed

    Kozlowski, K H; Szaykowski, A; Danysz, A

    1977-01-01

    Pentobarbital (PB), at dose range of 20--50 mg/kg, displays in rabbits non-linear, dose-dependent kinetics. Pharmacokinetics parameters of drug elimination depend largely upon the dose, while the distribution phase is dose-independent. The rate of disappearance of PB from the central compartment (plasma) decreases with the increase of the dose. The analysis of pharmacodynamic parameters has shown that this dose-dependent retardation of PB elimination is probably caused by an impairment of metabolic processes, resulting from disturbance of the circulatory system. A close correlation has been found between the hypotensive effect of PB and the elimination constant, k13, and also between the hypotensive effect and beta.Vd(extrap), a coefficient proportional to the rate of metabolism of PB [23, 29]. The results indicate the necessity of considering the changes in the functional state of the organism, related to the action of a drug, in pharmacokinetic studies.

  15. EUV-induced oxidation of carbon on TiO2.

    PubMed

    Faradzhev, Nadir S; Hill, Shannon B

    2016-10-01

    Previously we reported estimates of the maximum etch rates of C on TiO 2 by oxidizers including NO, O 3 and H 2 O 2 when irradiated by a spatially-non-uniform beam of extreme ultraviolet (EUV) radiation at 13.5 nm (Faradzhev et al., 2013). Here we extend that work by presenting temporally and spatially resolved measurements of the C etching by these oxidizers as a function of EUV intensity in the range (0.3 to 3) mW/mm 2 [(0.2 to 2) × 10 16 photons s -1 cm -2 ]. We find that the rates for NO scale linearly with intensity and are smaller than those for O 3 , which exhibit a weak, sub-linear intensity dependence in this range. We demonstrate that these behaviors are consistent with adsorption of the oxidizing precursor on the C surface followed by a photon-stimulated reaction resulting in volatile C-containing products. The kinetics of photon-induced C etching by hydrogen peroxide, however, appear to be more complex. The spatially resolved measurements reveal that C removal by H 2 O 2 begins at the edges of the C spot, where the light intensity is the lowest, and proceeds toward the center of the spot. This localization of the reaction may occur because hydroxyl radicals are produced efficiently on the catalytically active TiO 2 surface.

  16. From mobile phone data to the spatial structure of cities

    PubMed Central

    Louail, Thomas; Lenormand, Maxime; Cantu Ros, Oliva G.; Picornell, Miguel; Herranz, Ricardo; Frias-Martinez, Enrique; Ramasco, José J.; Barthelemy, Marc

    2014-01-01

    Pervasive infrastructures, such as cell phone networks, enable to capture large amounts of human behavioral data but also provide information about the structure of cities and their dynamical properties. In this article, we focus on these last aspects by studying phone data recorded during 55 days in 31 Spanish cities. We first define an urban dilatation index which measures how the average distance between individuals evolves during the day, allowing us to highlight different types of city structure. We then focus on hotspots, the most crowded places in the city. We propose a parameter free method to detect them and to test the robustness of our results. The number of these hotspots scales sublinearly with the population size, a result in agreement with previous theoretical arguments and measures on employment datasets. We study the lifetime of these hotspots and show in particular that the hierarchy of permanent ones, which constitute the ‘heart' of the city, is very stable whatever the size of the city. The spatial structure of these hotspots is also of interest and allows us to distinguish different categories of cities, from monocentric and “segregated” where the spatial distribution is very dependent on land use, to polycentric where the spatial mixing between land uses is much more important. These results point towards the possibility of a new, quantitative classification of cities using high resolution spatio-temporal data. PMID:24923248

  17. Balancing high gain and bandwidth in multilayer organic photodetectors with tailored carrier blocking layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammond, William T.; Mudrick, John P.; Xue, Jiangeng, E-mail: jxue@mse.ufl.edu

    2014-12-07

    We present detailed studies of the high photocurrent gain behavior in multilayer organic photodiodes containing tailored carrier blocking layers we reported earlier in a Letter [W. T. Hammond and J. Xue, Appl. Phys. Lett. 97, 073302 (2010)], in which a high photocurrent gain of up to 500 was attributed to the accumulation of photogenerated holes at the anode/organic active layer interface and the subsequent drastic increase in secondary electron injection from the anode. Here, we show that both the hole-blocking layer structure and layer thickness strongly influence the magnitude of the photocurrent gain. Temporal studies revealed that the frequency responsemore » of such devices is limited by three different processes with lifetimes of 10 μs, 202 μs, and 2.72 ms for the removal of confined holes, which limit the 3 dB bandwidth of these devices to 1.4 kHz. Furthermore, the composition in the mixed organic donor-acceptor photoactive layer affects both gain and bandwidth, which is attributed to the varying charge transport characteristics, and the optimal gain-bandwidth product is achieved with approximately 30% donor content. Finally, these devices show a high dynamic range of more than seven orders of magnitude, although the photocurrent shows a sublinear dependence on the incident optical power.« less

  18. Dose-Dependent Model of Caffeine Effects on Human Vigilance during Total Sleep Deprivation

    DTIC Science & Technology

    2014-05-20

    does not consider the absorption of caffeine . This is a reasonable approximation for caffeine when ingested via coffee , tea, energy drinks, and most...Dose-dependent model of caffeine effects on human vigilance during total sleep deprivation Sridhar Ramakrishnan a, Srinivas Laxminarayan a, Nancy J...We modeled the dose-dependent effects of caffeine on human vigilance. The model predicted the effects of both single and repeated caffeine doses

  19. SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talarico, O; Krylova, T; Lebedenko, I

    Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dosemore » rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.« less

  20. Fixation probability of a nonmutator in a large population of asexual mutators.

    PubMed

    Jain, Kavita; James, Ananthu

    2017-11-21

    In an adapted population of mutators in which most mutations are deleterious, a nonmutator that lowers the mutation rate is under indirect selection and can sweep to fixation. Using a multitype branching process, we calculate the fixation probability of a rare nonmutator in a large population of asexual mutators. We show that when beneficial mutations are absent, the fixation probability is a nonmonotonic function of the mutation rate of the mutator: it first increases sublinearly and then decreases exponentially. We also find that beneficial mutations can enhance the fixation probability of a nonmutator. Our analysis is relevant to an understanding of recent experiments in which a reduction in the mutation rates has been observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Flexible Proton-Gated Oxide Synaptic Transistors on Si Membrane.

    PubMed

    Zhu, Li Qiang; Wan, Chang Jin; Gao, Ping Qi; Liu, Yang Hui; Xiao, Hui; Ye, Ji Chun; Wan, Qing

    2016-08-24

    Ion-conducting materials have received considerable attention for their applications in fuel cells, electrochemical devices, and sensors. Here, flexible indium zinc oxide (InZnO) synaptic transistors with multiple presynaptic inputs gated by proton-conducting phosphorosilicate glass-based electrolyte films are fabricated on ultrathin Si membranes. Transient characteristics of the proton gated InZnO synaptic transistors are investigated, indicating stable proton-gating behaviors. Short-term synaptic plasticities are mimicked on the proposed proton-gated synaptic transistors. Furthermore, synaptic integration regulations are mimicked on the proposed synaptic transistor networks. Spiking logic modulations are realized based on the transition between superlinear and sublinear synaptic integration. The multigates coupled flexible proton-gated oxide synaptic transistors may be interesting for neuroinspired platforms with sophisticated spatiotemporal information processing.

  2. Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology

    PubMed Central

    Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T

    2012-01-01

    Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136

  3. Method to determine the position-dependant metal correction factor for dose-rate equivalent laser testing of semiconductor devices

    DOEpatents

    Horn, Kevin M.

    2013-07-09

    A method reconstructs the charge collection from regions beneath opaque metallization of a semiconductor device, as determined from focused laser charge collection response images, and thereby derives a dose-rate dependent correction factor for subsequent broad-area, dose-rate equivalent, laser measurements. The position- and dose-rate dependencies of the charge-collection magnitude of the device are determined empirically and can be combined with a digital reconstruction methodology to derive an accurate metal-correction factor that permits subsequent absolute dose-rate response measurements to be derived from laser measurements alone. Broad-area laser dose-rate testing can thereby be used to accurately determine the peak transient current, dose-rate response of semiconductor devices to penetrating electron, gamma- and x-ray irradiation.

  4. Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Jong, W. L.; Ung, N. M.; Tiong, A. H. L.; Rosenfeld, A. B.; Wong, J. H. D.

    2018-03-01

    The aim of this study is to investigate the fundamental dosimetric characteristics of the MOSkin detector for megavoltage electron beam dosimetry. The reproducibility, linearity, energy dependence, dose rate dependence, depth dose measurement, output factor measurement, and surface dose measurement under megavoltage electron beam were tested. The MOSkin detector showed excellent reproducibility (>98%) and linearity (R2= 1.00) up to 2000 cGy for 4-20 MeV electron beams. The MOSkin detector also showed minimal dose rate dependence (within ±3%) and energy dependence (within ±2%) over the clinical range of electron beams, except for an energy dependence at 4 MeV electron beam. An energy dependence correction factor of 1.075 is needed when the MOSkin detector is used for 4 MeV electron beam. The output factors measured by the MOSkin detector were within ±2% compared to those measured with the EBT3 film and CC13 chamber. The measured depth doses using the MOSkin detector agreed with those measured using the CC13 chamber, except at the build-up region due to the dose volume averaging effect of the CC13 chamber. For surface dose measurements, MOSkin measurements were in agreement within ±3% to those measured using EBT3 film. Measurements using the MOSkin detector were also compared to electron dose calculation algorithms namely the GGPB and eMC algorithms. Both algorithms were in agreement with measurements to within ±2% and ±4% for output factor (except for the 4 × 4 cm2 field size) and surface dose, respectively. With the uncertainties taken into account, the MOSkin detector was found to be a suitable detector for dose measurement under megavoltage electron beam. This has been demonstrated in the in vivo skin dose measurement on patients during electron boost to the breast tumour bed.

  5. Dose-Dependent Pheromone Responses of Ips pini, Orthotomicus latiden (Coleoptera: Scolytidae), and associates in stands of lodgepole pine

    Treesearch

    Daniel R. Miller; John H. Borden; B. Staffan Lidgren

    2005-01-01

    We conducted four behavioral choice tests in stands of mature lodgepole pine in British Columbia, from 1988 to 1991, to determine the dose-dependent responses of Orthotomicus latidens (LeConte) and Ips pini (Say) to their respective pheromones. Dose-dependent responses were exhibited by I. pini to (±)-ipsdienol and lanierone, with...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Christian; Pawelke, Joerg; Karsch, Leonhard

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the filmmore » response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.« less

  7. Dose and dose rate effects of whole-body proton-irradiation on lymphocyte blastogenesis and hematological variables: part II

    NASA Technical Reports Server (NTRS)

    Pecaut, Michael J.; Gridley, Daila S.; Smith, Anna L.; Nelson, Gregory A.

    2002-01-01

    The goal of part II of this study was to evaluate functional characteristics of leukocytes and circulating blood cell parameters after whole-body proton irradiation at varying doses and at low- and high-dose-rates (LDR and HDR, respectively). C57BL/6 mice (n=51) were irradiated and euthanized at 4 days post-exposure for assay. Significant radiation dose- (but not dose-rate-) dependent decreases were observed in splenocyte responses to T and B cell mitogens when compared to sham-irradiated controls (P<0.001). Spontaneous blastogenesis, also significantly dose-dependent, was increased in both blood and spleen (P<0.001). Red blood cell counts, hemoglobin concentration, and hematocrit were decreased in a dose-dependent manner (P<0.05), whereas thrombocyte numbers were only slightly affected. Comparison of proton- and gamma-irradiated groups (both receiving 3 Gy at HDR) showed a higher level of spontaneous blastogenesis in blood leukocytes and a lower splenocyte response to concanavalin A following proton irradiation (P<0.05). There were no dose rate effects. Collectively, the data demonstrate that the measurements in blood and spleen were largely dependent upon the total dose of proton radiation and that an 80-fold difference in the dose rate was not a significant factor. A difference, however, was found between protons and gamma-rays in the degree of change induced in some of the measurements.

  8. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels

    NASA Astrophysics Data System (ADS)

    Khan, Muzafar; Heilemann, Gerd; Kuess, Peter; Georg, Dietmar; Berg, Andreas

    2018-03-01

    Recent developments in radiation therapy aimed at more precise dose delivery along with higher dose gradients (dose painting) and more efficient dose delivery with higher dose rates e.g. flattening filter free (FFF) irradiation. Magnetic-resonance-imaging based polymer gel dosimetry offers 3D information for precise dose delivery techniques. Many of the proposed polymer gels have been reported to exhibit a dose response, measured as relaxation rate ΔR2(D), which is dose rate dependent. A lack of or a reduced dose-rate sensitivity is very important for dosimetric accuracy, especially with regard to the increasing clinical use of FFF irradiation protocols with LINACs at high dose rates. Some commonly used polymer gels are based on Methacrylic-Acid-Gel-Initiated-by-Copper (MAGIC). Here, we report on the dose sensitivity (ΔR2/ΔD) of MAGIC-type gels with different oxygen scavenger concentration for their specific dependence on the applied dose rate in order to improve the dosimetric performance, especially for high dose rates. A preclinical x-ray machine (‘Yxlon’, E  =  200 kV) was used for irradiation to cover a range of dose rates from low \\dot{D} min  =  0.6 Gy min-1 to high \\dot{D} max  =  18 Gy min-1. The dose response was evaluated using R2-imaging of the gel on a human high-field (7T) MR-scanner. The results indicate that all of the investigated dose rates had an impact on the dose response in polymer gel dosimeters, being strongest in the high dose region and less effective for low dose levels. The absolute dose rate dependence \\frac{(Δ R2/Δ D)}{Δ \\dot{D}} of the dose response in MAGIC-type gel is significantly reduced using higher concentrations of oxygen scavenger at the expense of reduced dose sensitivity. For quantitative dose evaluations the relative dose rate dependence of a polymer gel, normalized to its sensitivity is important. Based on this normalized sensitivity the dose rate sensitivity was reduced distinctly using an increased oxygen scavenger concentration with reference to standard MAGIC-type gel formulation at high dose rate levels. The proposed gel composition with high oxygen scavenger concentration exhibits a larger linear active dose response and might be used especially in FFF-radiation applications and preclinical dosimetry at high dose rates. We propose in general to use high dose rates for calibration and evaluation as the change in relative dose sensitivity is reduced at higher dose rates in all of the investigated gel types.

  9. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    PubMed

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p range attainable at the prototype linac confirming the absence of any dose-rate dependence within the investigated range (7 × 10 3 to 8 × 10 6 Gy/s). This aspect was further corroborated by the linear relationship between the dose-per-pulse (D p ) measured by films and the charge per pulse (C p ) measured at the prototype linac exit. Our study shows that the use of EBT3 Gafchromic films can be extended to reference dosimetry in pulsed electron beams with a very high dose rate. The measurement results are associated with an overall uncertainty below 4% (k = 2) and are dose-rate and energy independent. © 2016 American Association of Physicists in Medicine.

  10. Dose-dependent metabolic disposition of hydroxytyrosol and formation of mercapturates in rats.

    PubMed

    Kotronoulas, Aristotelis; Pizarro, Nieves; Serra, Aida; Robledo, Patricia; Joglar, Jesús; Rubió, Laura; Hernaéz, Alvaro; Tormos, Carmen; Motilva, Ma José; Fitó, Montserrat; Covas, Maria-Isabel; Solà, Rosa; Farré, Magí; Saez, Guillermo; de la Torre, Rafael

    2013-11-01

    Hydroxytyrosol (HT), one of the major polyphenols present in olive oil, is known to possess a high antioxidant capacity. The aim of the present study was to investigate dose dependent (0, 1, 10 and 100 mg/kg) alterations in the metabolism of HT in rats since it has been reported that metabolites may contribute to biological effects. Special attention was paid to the activation of the semiquinone-quinone oxidative cycle and the formation of adducts with potential deleterious effects. Thus, we developed a novel analytical methodology to monitor the in vivo formation of the HT mercapturate, N-acetyl-5-S-cysteinyl-hydroxytyrosol in urine samples. Biomarkers of hepatic and renal toxicity were evaluated within the dose range tested. Following HT administration, dose-dependent effects were observed for the recovery of all the metabolites studied. At the lowest dose of 1 mg/kg, the glucuronidation pathway was the most relevant (25-30%), with lower recoveries for sulfation (14%), while at the highest dose of 100 mg/kg, sulfation was the most prevalent (75%). In addition, we report for the first time the formation of the mercapturate conjugate of HT in a dose-dependent manner. The biochemical data did not reveal significant toxic effects of HT at any of the doses studied. An increase in the GSH/GSSG ratio at the highest dose was observed indicating that the products of HT autoxidation are counteracted by glutathione, resulting in their detoxification. These results indicate that the metabolic disposition of HT is highly dependent on the dose ingested. Copyright © 2013. Published by Elsevier Ltd.

  11. Dose-Dependent Suppression of Gonadotropins and Ovarian Hormones by Elagolix in Healthy Premenopausal Women.

    PubMed

    Ng, Juki; Chwalisz, Kristof; Carter, David C; Klein, Cheri E

    2017-05-01

    Elagolix is a nonpeptide, oral gonadotropin-releasing hormone (GnRH) antagonist being developed for sex-hormone-dependent diseases in women. We evaluated the pharmacokinetics and pharmacodynamics of elagolix. This study was a randomized, double-blind, placebo-controlled, multiple-ascending dose study in 45 healthy premenopausal women at a research unit. Elagolix [150 mg once daily or 100, 200, 300, or 400 mg twice daily (BID)] or placebo was administered for 21 days. Main outcome measures were elagolix pharmacokinetics, suppression of gonadotropics [follicle-stimulating hormone (FSH), luteinizing hormone (LH)] and ovarian hormones [estradiol (E2), progesterone (P)], and adverse events. Elagolix was rapidly absorbed after oral dosing, reaching maximum concentrations at 1.0 to 1.5 hours, with a half-life of 4 to 6 hours. FSH, LH, and E2 were suppressed within hours of elagolix administration on day 1. Dose-dependent suppression of E2 was observed, with maximum suppression achieved with elagolix 200 mg BID. Dose-dependent suppression of FSH and LH was also observed, with maximal or near-maximal suppression achieved at 300 mg BID and 200 mg BID, respectively. At elagolix doses ≥100 mg BID, P concentrations remained at anovulatory levels throughout 21 days of dosing. The most frequently reported adverse events were headache and hot flush. Elagolix administration allows for modulation of gonadotropin and ovarian hormone concentrations, from partial suppression at lower doses to nearly full suppression at higher doses. The results of this study provide a rationale for elagolix dose selection for treatment of sex hormone-dependent diseases in women. Copyright © 2017 Endocrine Society

  12. Optically Stimulated Luminescent Dosimetry for High Dose Rate Brachytherapy

    PubMed Central

    Tien, Christopher Jason; Ebeling, Robert; Hiatt, Jessica R.; Curran, Bruce; Sternick, Edward

    2012-01-01

    Purpose: The objective was to determine whether optically stimulated luminescent dosimeters (OSLDs) were appropriate for in vivo measurements in high dose rate brachytherapy. In order to make this distinction, three dosimetric characteristics were tested: dose linearity, dose rate dependence, and angular dependence. The Landauer nanoDot™ OSLDs were chosen due to their popularity and their availability commercially. Methods: To test the dose linearity, each OSLD was placed at a constant location and the dwell time was varied. Next, in order to test the dose rate dependence, each OSLD was placed at different OLSD-to-source distances and the dwell time was held constant. A curved geometry was created using a circular Accuboost® applicator in order to test angular dependence. Results: The OSLD response remained linear for high doses and was independent of dose rate. For doses up to 600 cGy, the linear coefficient of determination was 0.9988 with a response of 725 counts per cGy. The angular dependence was significant only in “edge-on” scenarios. Conclusion: OSLDs are conveniently read out using commercially available readers. OSLDs can be re-read and serve as a permanent record for clinical records or be annealed using conventional fluorescent light. Lastly, OSLDs are produced commercially for $5 each. Due to these convenient features, in conjunction with the dosimetric performance, OSLDs should be considered a clinically feasible and attractive tool for in vivo HDR brachytherapy measurements. PMID:22888476

  13. An evaluation of some pertinent parameters that influence the dosimetric performance of synthetic diamond detectors

    NASA Astrophysics Data System (ADS)

    Ade, N.; Nam, T. L.; Mhlanga, S. H.

    2013-05-01

    Although the near-tissue equivalence of diamond allows the direct measurement of dose for clinical applications without the need for energy-corrections, it is often cited that diamond detectors require pre-irradiation, a procedure necessary to stabilize the response or sensitivity of a diamond detector before dose measurements. In addition it has been pointed out that the relative dose measured with a diamond detector requires dose rate dependence correction and that the angular dependence of a detector could be due to its mechanical design or to the intrinsic angular sensitivity of the detection process. While the cause of instability of response has not been meticulously investigated, the issue of dose rate dependence correction is uncertain as some studies ignored it but reported good results. The aims of this study were therefore to investigate, in particular (1) the major cause of the unstable response of diamond detectors requiring pre-irradiation; (2) the influence of dose rate dependence correction in relative dose measurements; and (3) the angular dependence of the diamond detectors. The study was conducted with low-energy X-rays and electron therapy beams on HPHT and CVD synthesized diamonds. Ionization chambers were used for comparative measurements. Through systematic investigations, the major cause of the unstable response of diamond detectors requiring the recommended pre-irradiation step was isolated and attributed to the presence and effects of ambient light. The variation in detector's response between measurements in light and dark conditions could be as high as 63% for a CVD diamond. Dose rate dependence parameters (Δ values) of 0.950 and 1.035 were found for the HPHT and CVD diamond detectors, respectively. Without corrections based on dose rate dependence, the relative differences between depth-doses measured with the diamond detectors and a Markus chamber for exposures to 7 and 14 MeV electron beams were within 2.5%. A dose rate dependence correction using the Δ values obtained seemed to worsen the performance of the HPHT sample (up to about 3.3%) but it had a marginal effect on the performance of the CVD sample. In addition, the angular response of the CVD diamond detector was shown to be comparable with that of a cylindrical chamber. This study concludes that once the responses of the diamond detectors have been stabilised and they are properly shielded from ambient light, pre-irradiation prior to each measurement is not required. Also, the relative dose measured with the diamond detectors do not require dose rate dependence corrections as the required correction is only marginal and could have no dosimetric significance.

  14. Dose and dose rate effects of whole-body gamma-irradiation: I. Lymphocytes and lymphoid organs

    NASA Technical Reports Server (NTRS)

    Pecaut, M. J.; Nelson, G. A.; Gridley, D. S.

    2001-01-01

    The major goal of part I of this study was to compare varying doses and dose rates of whole-body gamma-radiation on lymphoid cells and organs. C57BL/6 mice (n = 75) were exposed to 0, 0.5, 1.5, and 3.0 Gy gamma-rays (60Co) at 1 cGy/min (low-dose rate, LDR) and 80 cGy/min (high-dose rate, HDR) and euthanized 4 days later. A significant dose-dependent loss of spleen mass was observed with both LDR and HDR irradiation; for the thymus this was true only with HDR. Decreasing leukocyte and lymphocyte numbers occurred with increasing dose in blood and spleen at both dose rates. The numbers (not percentages) of CD3+ T lymphocytes decreased in the blood in a dose-dependent manner at both HDR and LDR. Splenic T cell counts decreased with dose only in HDR groups; percentages increased with dose at both dose rates. Dose-dependent decreases occurred in CD4+ T helper and CD8+ T cytotoxic cell counts at HDR and LDR. In the blood the percentages of CD4+ cells increased with increasing dose at both dose rates, whereas in the spleen the counts decreased only in the HDR groups. The percentages of the CD8+ population remained stable in both blood and spleen. CD19+ B cell counts and percentages in both compartments declined markedly with increasing HDR and LDR radiation. NK1.1+ natural killer cell numbers and proportions remained relatively stable. Overall, these data indicate that the observed changes were highly dependent on the dose, but not dose rate, and that cells in the spleen are more affected by dose rate than those in blood. The results also suggest that the response of lymphocytes in different body compartments may be variable.

  15. Concentration rather than dose defines the local brain toxicity of agents that are effectively distributed by convection-enhanced delivery.

    PubMed

    Zhang, Rong; Saito, Ryuta; Mano, Yui; Kanamori, Masayuki; Sonoda, Yukihiko; Kumabe, Toshihiro; Tominaga, Teiji

    2014-01-30

    Convection-enhanced delivery (CED) has been developed as a potentially effective drug-delivery strategy into the central nervous system. In contrast to systemic intravenous administration, local delivery achieves high concentration and prolonged retention in the local tissue, with increased chance of local toxicity, especially with toxic agents such as chemotherapeutic agents. Therefore, the factors that affect local toxicity should be extensively studied. With the assumption that concentration-oriented evaluation of toxicity is important for local CED, we evaluated the appearance of local toxicity among different agents after delivery with CED and studied if it is dose dependent or concentration dependent. Local toxicity profile of chemotherapeutic agents delivered via CED indicates BCNU was dose-dependent, whereas that of ACNU was concentration-dependent. On the other hand, local toxicity for doxorubicin, which is not distributed effectively by CED, was dose-dependent. Local toxicity for PLD, which is extensively distributed by CED, was concentration-dependent. Traditional evaluation of drug induced toxicity was dose-oriented. This is true for systemic intravascular delivery. However, with local CED, toxicity of several drugs exacerbated in concentration-dependent manner. From our study, local toxicity of drugs that are likely to distribute effectively tended to be concentration-dependent. Concentration rather than dose may be more important for the toxicity of agents that are effectively distributed by CED. Concentration-oriented evaluation of toxicity is more important for CED. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II.

    PubMed

    Tsuda, S; Yoshida, T; Tsutsumi, M; Saito, K

    2015-01-01

    The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. The correlation between elongation at break and thermal decomposition of aged EPDM cable polymer

    NASA Astrophysics Data System (ADS)

    Šarac, T.; Devaux, J.; Quiévy, N.; Gusarov, A.; Konstantinović, M. J.

    2017-03-01

    The effect of simultaneous thermal and gamma irradiation ageing on the mechanical and physicochemical properties of industrial EPDM was investigated. Accelerated ageing, covering a wide range of dose rates, doses and temperatures, was preformed in stagnant air on EPDM polymer samples extracted from the cables in use in the Belgian nuclear power plants. The mechanical properties, ultimate tensile stress and elongation at break, are found to exhibit the strong dependence on the dose, ageing temperature and dose rate. The thermal decomposition of aged polymer is observed to be the dose dependent when thermogravimetry test is performed under air atmosphere. No dose dependence is observed when thermal decomposition is performed under nitrogen atmosphere. The thermal decomposition rates are found to fully mimic the reduction of elongation at break for all dose rates and ageing temperatures. This effect is argued to be the result of thermal and radiation mediated oxidation degradation process.

  18. Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms

    NASA Astrophysics Data System (ADS)

    Zacharatou Jarlskog, Christina; Lee, Choonik; Bolch, Wesley E.; Xu, X. George; Paganetti, Harald

    2008-02-01

    Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the target requires whole-body geometrical information. Furthermore, because the patient geometry depends on age at exposure, age-dependent representations are also needed. We implemented age-dependent phantoms into our proton Monte Carlo dose calculation environment. We considered eight typical radiation fields, two of which had been previously used to treat pediatric patients. The other six fields were additionally considered to allow a systematic study of equivalent doses as a function of field parameters. For all phantoms and all fields, we simulated organ-specific equivalent neutron doses and analyzed for each organ (1) the equivalent dose due to neutrons as a function of distance to the target; (2) the equivalent dose due to neutrons as a function of patient age; (3) the equivalent dose due to neutrons as a function of field parameters; and (4) the ratio of contributions to secondary dose from the treatment head versus the contribution from the patient's body tissues. This work reports organ-specific equivalent neutron doses for up to 48 organs in a patient. We demonstrate quantitatively how organ equivalent doses for adult and pediatric patients vary as a function of patient's age, organ and field parameters. Neutron doses increase with increasing range and modulation width but decrease with field size (as defined by the aperture). We analyzed the ratio of neutron dose contributions from the patient and from the treatment head, and found that neutron-equivalent doses fall off rapidly as a function of distance from the target, in agreement with experimental data. It appears that for the fields used in this study, the neutron dose lateral to the field is smaller than the reported scattered photon doses in a typical intensity-modulated photon treatment. Most importantly, our study shows that neutron doses to specific organs depend considerably on the patient's age and body stature. The younger the patient, the higher the dose deposited due to neutrons. Given the fact that the risk also increases with decreasing patient age, this factor needs to be taken into account when treating pediatric patients of very young ages and/or of small body size. The neutron dose from a course of proton therapy treatment (assuming 70 Gy in 30 fractions) could potentially (depending on patient's age, organ, treatment site and area of CT scan) be equivalent to up to ~30 CT scans.

  19. Obtaining the Optimal Dose in Alcohol Dependence Studies

    PubMed Central

    Wages, Nolan A.; Liu, Lei; O’Quigley, John; Johnson, Bankole A.

    2012-01-01

    In alcohol dependence studies, the treatment effect at different dose levels remains to be ascertained. Establishing this effect would aid us in identifying the best dose that has satisfactory efficacy while minimizing the rate of adverse events. We advocate the use of dose-finding methodology that has been successfully implemented in the cancer and HIV settings to identify the optimal dose in a cost-effective way. Specifically, we describe the continual reassessment method (CRM), an adaptive design proposed for cancer trials to reconcile the needs of dose-finding experiments with the ethical demands of established medical practice. We are applying adaptive designs for identifying the optimal dose of medications for the first time in the context of pharmacotherapy research in alcoholism. We provide an example of a topiramate trial as an illustration of how adaptive designs can be used to locate the optimal dose in alcohol treatment trials. It is believed that the introduction of adaptive design methods will enable the development of medications for the treatment of alcohol dependence to be accelerated. PMID:23189064

  20. Dependence of normal brain integral dose and normal tissue complication probability on the prescription isodose values for γ-knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Ma, Lijun

    2001-11-01

    A recent multi-institutional clinical study suggested possible benefits of lowering the prescription isodose lines for stereotactic radiosurgery procedures. In this study, we investigate the dependence of the normal brain integral dose and the normal tissue complication probability (NTCP) on the prescription isodose values for γ-knife radiosurgery. An analytical dose model was developed for γ-knife treatment planning. The dose model was commissioned by fitting the measured dose profiles for each helmet size. The dose model was validated by comparing its results with the Leksell gamma plan (LGP, version 5.30) calculations. The normal brain integral dose and the NTCP were computed and analysed for an ensemble of treatment cases. The functional dependence of the normal brain integral dose and the NCTP versus the prescribing isodose values was studied for these cases. We found that the normal brain integral dose and the NTCP increase significantly when lowering the prescription isodose lines from 50% to 35% of the maximum tumour dose. Alternatively, the normal brain integral dose and the NTCP decrease significantly when raising the prescribing isodose lines from 50% to 65% of the maximum tumour dose. The results may be used as a guideline for designing future dose escalation studies for γ-knife applications.

  1. Space-Time Dependent Transport, Activation, and Dose Rates for Radioactivated Fluids.

    NASA Astrophysics Data System (ADS)

    Gavazza, Sergio

    Two methods are developed to calculate the space - and time-dependent mass transport of radionuclides, their production and decay, and the associated dose rates generated from the radioactivated fluids flowing through pipes. The work couples space- and time-dependent phenomena, treated as only space- or time-dependent in the open literature. The transport and activation methodology (TAM) is used to numerically calculate space- and time-dependent transport and activation of radionuclides in fluids flowing through pipes exposed to radiation fields, and volumetric radioactive sources created by radionuclide motions. The computer program Radionuclide Activation and Transport in Pipe (RNATPA1) performs the numerical calculations required in TAM. The gamma ray dose methodology (GAM) is used to numerically calculate space- and time-dependent gamma ray dose equivalent rates from the volumetric radioactive sources determined by TAM. The computer program Gamma Ray Dose Equivalent Rate (GRDOSER) performs the numerical calculations required in GAM. The scope of conditions considered by TAM and GAM herein include (a) laminar flow in straight pipe, (b)recirculating flow schemes, (c) time-independent fluid velocity distributions, (d) space-dependent monoenergetic neutron flux distribution, (e) space- and time-dependent activation process of a single parent nuclide and transport and decay of a single daughter radionuclide, and (f) assessment of space- and time-dependent gamma ray dose rates, outside the pipe, generated by the space- and time-dependent source term distributions inside of it. The methodologies, however, can be easily extended to include all the situations of interest for solving the phenomena addressed in this dissertation. A comparison is made from results obtained by the described calculational procedures with analytical expressions. The physics of the problems addressed by the new technique and the increased accuracy versus non -space and time-dependent methods are presented. The value of the methods is also discussed. It has been demonstrated that TAM and GAM can be used to enhance the understanding of the space- and time-dependent mass transport of radionuclides, their production and decay, and the associated dose rates related to radioactivated fluids flowing through pipes.

  2. Rosuvastatin protects against angiotensin II-induced renal injury in a dose-dependent fashion.

    PubMed

    Park, Joon-Keun; Mervaala, Eero Ma; Muller, Dominik N; Menne, Jan; Fiebeler, Anette; Luft, Friedrich C; Haller, Hermann

    2009-03-01

    We showed earlier that statin treatment ameliorates target-organ injury in a transgenic model of angiotensin (Ang) II-induced hypertension. We now test the hypothesis that rosuvastatin (1, 10, and 50 mg/kg/day) influences leukocyte adhesion and infiltration, prevents induction of inducible nitric oxide synthase (iNOS), and ameliorates target-organ damage in a dose-dependent fashion. We treated rats harboring the human renin and human angiotensinogen genes (dTGR) from week 4 to 8 (n = 20 per group). Untreated dTGR developed severe hypertension, cardiac hypertrophy, and renal damage, with a 100-fold increased albuminuria and focal cortical necrosis. Mortality of untreated dTGR at age 8 weeks was 59%. Rosuvastatin treatment decreased mortality dose-dependently. Blood pressure was not affected. Albuminuria was reduced dose-dependently. Interstitial adhesion molecule (ICAM)-1 expression was markedly reduced by rosuvastatin, as were neutrophil and monocyte infiltration. Immunohistochemistry showed an increased endothelial and medial iNOS expression in small vessels, infiltrating cells, afferent arterioles, and glomeruli of dTGR. Immunoreactivity was stronger in cortex than medulla. Rosuvastatin markedly reduced the iNOS expression in both cortex and medulla. Finally, matrix protein (type IV collagen, fibronectin) expression was also dose- dependently reduced by rosuvastatin. Our findings indicate that rosuvastatin dose- dependently ameliorates angiotensin II-induced-organ damage and almost completely prevents inflammation at the highest dose. The data implicate 3-hydroxy-3-methylglutaryl coenzyme A function in signaling events leading to target-organ damage.

  3. Fast Exact Search in Hamming Space With Multi-Index Hashing.

    PubMed

    Norouzi, Mohammad; Punjani, Ali; Fleet, David J

    2014-06-01

    There is growing interest in representing image data and feature descriptors using compact binary codes for fast near neighbor search. Although binary codes are motivated by their use as direct indices (addresses) into a hash table, codes longer than 32 bits are not being used as such, as it was thought to be ineffective. We introduce a rigorous way to build multiple hash tables on binary code substrings that enables exact k-nearest neighbor search in Hamming space. The approach is storage efficient and straight-forward to implement. Theoretical analysis shows that the algorithm exhibits sub-linear run-time behavior for uniformly distributed codes. Empirical results show dramatic speedups over a linear scan baseline for datasets of up to one billion codes of 64, 128, or 256 bits.

  4. CO2 detection using polyethylenimine/starch functionalized AlGaN /GaN high electron mobility transistors

    NASA Astrophysics Data System (ADS)

    Chang, C. Y.; Kang, B. S.; Wang, H. T.; Ren, F.; Wang, Y. L.; Pearton, S. J.; Dennis, D. M.; Johnson, J. W.; Rajagopal, P.; Roberts, J. C.; Piner, E. L.; Linthicum, K. J.

    2008-06-01

    AlGaN /GaN high electron mobility transistors (HEMTs) functionalized with polyethylenimine/starch were used for detecting CO2 with a wide dynamic range of 0.9%-50% balanced with nitrogen at temperatures from 46to220°C. Higher detection sensitivity to CO2 gas was achieved at higher testing temperatures. At a fixed source-drain bias voltage of 0.5V, drain-source current of the functionalized HEMTs showed a sublinear correlation upon exposure to different CO2 concentrations at low temperature. The superlinear relationship was at high temperature. The sensor exhibited a reversible behavior and a repeatable current change of 32 and 47μA with the introduction of 28.57% and 37.5% CO2 at 108°C, respectively.

  5. Three-body Annihilation at the Onset of Anomalous Photocurrent Suppression in Vertical Heterostrucutres of MoTe2

    NASA Astrophysics Data System (ADS)

    Arp, Trevor; Pleskot, Dennis; Gabor, Nathaniel

    We have developed a new photoresponse imaging technique that utilizes extensive data acquisition over a large parameter space. By acquiring a multi-dimensional data set, we fully capture the intrinsic optoelectronic response of two-dimensional heterostructure devices. Using this technique we have investigated the behavior of heterostructures consisting of molybdenum ditelluride (MoTe2) sandwiched between graphene top and bottom contacts. Under near-infrared optical excitation, the ultra-thin heterostructure devices exhibit sub-linear photocurrent response that recovers within several dozen picoseconds. As the optical power increases, the dynamics of the photoresponse, consistent with 3-body annihilation, precede a sudden suppression of photocurrent. The observed dynamics near the threshold to photocurrent suppression may indicate the onset to a strongly interacting population of electrons and holes.

  6. Investigation of the Nicole model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adam, C.; Sanchez-Guillen, J.; Vazquez, R.A.

    2006-05-15

    We study soliton solutions of the Nicole model - a non-linear four-dimensional field theory consisting of the CP{sup 1} Lagrangian density to the non-integer power (3/2) - using an ansatz within toroidal coordinates, which is indicated by the conformal symmetry of the static equations of motion. We calculate the soliton energies numerically and find that they grow linearly with the topological charge (Hopf index). Further we prove this behavior to hold exactly for the ansatz. On the other hand, for the full three-dimensional system without symmetry reduction we prove a sub-linear upper bound, analogously to the case of the Faddeev-Niemimore » model. It follows that symmetric solitons cannot be true minimizers of the energy for sufficiently large Hopf index, again in analogy to the Faddeev-Niemi model.« less

  7. Quality Assurance Testing of Version 1.3 of U.S. EPA Benchmark Dose Software (Presentation)

    EPA Science Inventory

    EPA benchmark dose software (BMDS) issued to evaluate chemical dose-response data in support of Agency risk assessments, and must therefore be dependable. Quality assurance testing methods developed for BMDS were designed to assess model dependability with respect to curve-fitt...

  8. Dose-dependent effects of lesogaberan on reflux measures in patients with refractory gastroesophageal reflux disease: a randomized, placebo-controlled study.

    PubMed

    Miner, Philip B; Silberg, Debra G; Ruth, Magnus; Miller, Frank; Pandolfino, John

    2014-11-18

    The γ-aminobutyric acid type B-receptor agonist lesogaberan (AZD3355) has been developed for use in patients with gastroesophageal reflux disease (GERD) symptoms despite proton pump inhibitor (PPI) therapy (partial responders). This study aimed to explore the dose-response effect of lesogaberan on reflux episodes in partial responders. In this randomized, single-centre, double-blind, crossover, placebo-controlled study, partial responders taking optimised PPI therapy were given 30, 90, 120 and 240 mg doses of lesogaberan. Each dose was given twice (12 h apart) during a 24-h period, during which impedance-pH measurements were taken. Twenty-five patients were included in the efficacy analysis and 27 in the safety analysis. The effect of lesogaberan on the mean number of reflux episodes was dose-dependent, and all doses significantly reduced the mean number of reflux episodes relative to placebo. Lesogaberan also dose-dependently reduced the mean number of acid reflux episodes (except the 30 mg dose) and weakly acid reflux episodes (all doses) significantly, relative to placebo. Regardless of dose, lesogaberan had a similar effect on the percentage of time with esophageal pH < 4 [mean reduction: 68.5% (30 mg), 54.2% (90 mg), 65.9% (120 mg), 72.1% (240 mg); p < 0.05 except 90 mg dose]. No adverse events led to discontinuation and no serious adverse events occurred during active treatment. Lesogaberan inhibited reflux in a dose-dependent manner in partial responders taking optimised PPI therapy, and these effects were significant versus placebo. All lesogaberan doses were well tolerated and were not associated with clinically relevant adverse events. ClinicalTrials.gov identifier: NCT01043185.

  9. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    PubMed

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  10. Search for ionisation density effects in the radiation absorption stage in LiF:Mg,Ti.

    PubMed

    Nail, I; Horowitz, Y S; Oster, L; Brandan, M E; Rodríguez-Villafuerte, M; Buenfil, A E; Ruiz-Trejo, C; Gamboa-Debuen, I; Avila, O; Tovar, V M; Olko, P; Ipe, N

    2006-01-01

    Optical absorption (OA) dose-response of LiF:Mg,Ti (TLD-100) is studied as a function of electron energy (ionisation density) and irradiation dose. Contrary to the situation in thermoluminescence dose-response where the supralinearity is strongly energy-dependent, no dependence of the OA dose filling constants on energy is observed. This result is interpreted as indicating a lack of competitive process in the radiation absorption stage. The lack of an energy dependence of the dose filling constant also suggests that the charge carrier migration distances are sufficiently large to smear out the differences in the non-uniform distribution of ionisation events created by the impinging gamma/electron radiation of various energies.

  11. Angular dependence of the MOSFET dosimeter and its impact on in vivo surface dose measurement in breast cancer treatment.

    PubMed

    Qin, S; Chen, T; Wang, L; Tu, Y; Yue, N; Zhou, J

    2014-08-01

    The focus of this study is the angular dependence of two types of Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeters (MOSFET20 and OneDose/OneDosePlus) when used for surface dose measurements. External beam radiationat different gantry angles were delivered to a cubic solid water phantom with a MOSFET placed on the top surface at CAX. The long axis of the MOSFET was oriented along the gantry axis of rotation, with the dosimeter (bubble side) facing the radiation source. MOSFET-measured surface doses were compared against calibrated radiochromic film readings. It was found that both types of MOSFET dosimeters exhibited larger than previously reported angular dependence when measuring surface dose in beams at large oblique angles. For the MOSFET20 dosimeter the measured surface dose deviation against film readings was as high as 17% when the incident angle was 72 degrees to the norm of the phantom surface. It is concluded that some MOSFET dosimeters may have a strong angular dependence when placed on the surface of water-equivalent material, even though they may have an isotropic angular response when surrounded by uniform medium. Extra on-surface calibration maybe necessary before using MOSFET dosimeters for skin dose measurement in tangential fields.

  12. Muon spin relaxation study of spin dynamics in the extended kagome systems YBaCo 4 O 7 + δ   ( δ = 0 , 0.1 )

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S.; Lee, Wonjun; Lee, K. J.

    Here, we present muon spin relaxation (μSR) measurements of the extended kagome systems YBaCo 4O 7+δ (δ = 0,0.1), comprising two interpenetrating kagome sublattice of Co(I) 3+ (S = 3/2) and a triangle sublattice of Co(II) 2+ (S = 2). The zero- and longitudinal-field μ SR spectra of the stoichiometric compound YBaCo 4O 7 unveil that the triangular subsystem orders at TN = 101 K. In contrast, the muon spin relaxation rate pertaining to the kagome subsystem shows persistent spin dynamics down to T = 20 K and then a sublinear decrease λ(T ) ~ T 0.66(5) on cooling towardsmore » T = 4 K. In addition, the introduction of interstitial oxygen (δ = 0.1) is found to drastically affect the magnetism. For the fast-cooling experiment (>10 K/min), YBaCo 4O 7.1 enters a regime characterized by persistent spin dynamics below 90 K. For the slow-cooling experiment (1 K/min), evidence is obtained for the phase separation into interstitial oxygen-poor and oxygen-rich regions with distinct correlation times. The observed temperature, cooling rate, and oxygen content dependencies of spin dynamics are discussed in terms of a broad range of spin-spin correlation times, relying on a different degree of frustration between the kagome and triangle sublattices as well as of oxygen migration.« less

  13. Optical identification of sulfur vacancies: Bound excitons at the edges of monolayer tungsten disulfide

    PubMed Central

    Carozo, Victor; Wang, Yuanxi; Fujisawa, Kazunori; Carvalho, Bruno R.; McCreary, Amber; Feng, Simin; Lin, Zhong; Zhou, Chanjing; Perea-López, Néstor; Elías, Ana Laura; Kabius, Bernd; Crespi, Vincent H.; Terrones, Mauricio

    2017-01-01

    Defects play a significant role in tailoring the optical properties of two-dimensional materials. Optical signatures of defect-bound excitons are important tools to probe defective regions and thus interrogate the optical quality of as-grown semiconducting monolayer materials. We have performed a systematic study of defect-bound excitons using photoluminescence (PL) spectroscopy combined with atomically resolved scanning electron microscopy and first-principles calculations. Spatially resolved PL spectroscopy at low temperatures revealed bound excitons that were present only on the edges of monolayer tungsten disulfide and not in the interior. Optical pumping of the bound excitons was sublinear, confirming their bound nature. Atomic-resolution images reveal that the areal density of monosulfur vacancies is much larger near the edges (0.92 ± 0.45 nm−2) than in the interior (0.33 ± 0.11 nm−2). Temperature-dependent PL measurements found a thermal activation energy of ~36 meV; surprisingly, this is much smaller than the bound-exciton binding energy of ~300 meV. We show that this apparent inconsistency is related to a thermal dissociation of the bound exciton that liberates the neutral excitons from negatively charged point defects. First-principles calculations confirm that sulfur monovacancies introduce midgap states that host optical transitions with finite matrix elements, with emission energies ranging from 200 to 400 meV below the neutral-exciton emission line. These results demonstrate that bound-exciton emission induced by monosulfur vacancies is concentrated near the edges of as-grown monolayer tungsten disulfide. PMID:28508048

  14. Opinion formation driven by PageRank node influence on directed networks

    NASA Astrophysics Data System (ADS)

    Eom, Young-Ho; Shepelyansky, Dima L.

    2015-10-01

    We study a two states opinion formation model driven by PageRank node influence and report an extensive numerical study on how PageRank affects collective opinion formations in large-scale empirical directed networks. In our model the opinion of a node can be updated by the sum of its neighbor nodes' opinions weighted by the node influence of the neighbor nodes at each step. We consider PageRank probability and its sublinear power as node influence measures and investigate evolution of opinion under various conditions. First, we observe that all networks reach steady state opinion after a certain relaxation time. This time scale is decreasing with the heterogeneity of node influence in the networks. Second, we find that our model shows consensus and non-consensus behavior in steady state depending on types of networks: Web graph, citation network of physics articles, and LiveJournal social network show non-consensus behavior while Wikipedia article network shows consensus behavior. Third, we find that a more heterogeneous influence distribution leads to a more uniform opinion state in the cases of Web graph, Wikipedia, and Livejournal. However, the opposite behavior is observed in the citation network. Finally we identify that a small number of influential nodes can impose their own opinion on significant fraction of other nodes in all considered networks. Our study shows that the effects of heterogeneity of node influence on opinion formation can be significant and suggests further investigations on the interplay between node influence and collective opinion in networks.

  15. Ubiquitous Instabilities of Dust Moving in Magnetized Gas

    NASA Astrophysics Data System (ADS)

    Hopkins, Philip F.; Squire, Jonathan

    2018-06-01

    Squire & Hopkins (2017) showed that coupled dust-gas mixtures are generically subject to "resonant drag instabilities" (RDIs), which drive violently-growing fluctuations in both. But the role of magnetic fields and charged dust has not yet been studied. We therefore explore the RDI in gas which obeys ideal MHD and is coupled to dust via both Lorentz forces and drag, with an external acceleration (e.g., gravity, radiation) driving dust drift through gas. We show this is always unstable, at all wavelengths and non-zero values of dust-to-gas ratio, drift velocity, dust charge, "stopping time" or drag coefficient (for any drag law), or field strength; moreover growth rates depend only weakly (sub-linearly) on these parameters. Dust charge and magnetic fields do not suppress instabilities, but give rise to a large number of new instability "families," each with distinct behavior. The "MHD-wave" (magnetosonic or Alfvén) RDIs exhibit maximal growth along "resonant" angles where the modes have a phase velocity matching the corresponding MHD wave, and growth rates increase without limit with wavenumber. The "gyro" RDIs are driven by resonances between drift and Larmor frequencies, giving growth rates sharply peaked at specific wavelengths. Other instabilities include "acoustic" and "pressure-free" modes (previously studied), and a family akin to cosmic ray instabilities which appear when Lorentz forces are strong and dust streams super-Alfvénically along field lines. We discuss astrophysical applications in the warm ISM, CGM/IGM, HII regions, SNe ejecta/remnants, Solar corona, cool-star winds, GMCs, and AGN.

  16. Role of Demographic Dynamics and Conflict in the Population-Area Relationship for Human Languages

    PubMed Central

    Manrubia, Susanna C.; Axelsen, Jacob B.; Zanette, Damián H.

    2012-01-01

    Many patterns displayed by the distribution of human linguistic groups are similar to the ecological organization described for biological species. It remains a challenge to identify simple and meaningful processes that describe these patterns. The population size distribution of human linguistic groups, for example, is well fitted by a log-normal distribution that may arise from stochastic demographic processes. As we show in this contribution, the distribution of the area size of home ranges of those groups also agrees with a log-normal function. Further, size and area are significantly correlated: the number of speakers and the area spanned by linguistic groups follow the allometric relation , with an exponent varying accross different world regions. The empirical evidence presented leads to the hypothesis that the distributions of and , and their mutual dependence, rely on demographic dynamics and on the result of conflicts over territory due to group growth. To substantiate this point, we introduce a two-variable stochastic multiplicative model whose analytical solution recovers the empirical observations. Applied to different world regions, the model reveals that the retreat in home range is sublinear with respect to the decrease in population size, and that the population-area exponent grows with the typical strength of conflicts. While the shape of the population size and area distributions, and their allometric relation, seem unavoidable outcomes of demography and inter-group contact, the precise value of could give insight on the cultural organization of those human groups in the last thousand years. PMID:22815726

  17. Muon spin relaxation study of spin dynamics in the extended kagome systems YBaCo 4 O 7 + δ   ( δ = 0 , 0.1 )

    DOE PAGES

    Lee, S.; Lee, Wonjun; Lee, K. J.; ...

    2018-03-15

    Here, we present muon spin relaxation (μSR) measurements of the extended kagome systems YBaCo 4O 7+δ (δ = 0,0.1), comprising two interpenetrating kagome sublattice of Co(I) 3+ (S = 3/2) and a triangle sublattice of Co(II) 2+ (S = 2). The zero- and longitudinal-field μ SR spectra of the stoichiometric compound YBaCo 4O 7 unveil that the triangular subsystem orders at TN = 101 K. In contrast, the muon spin relaxation rate pertaining to the kagome subsystem shows persistent spin dynamics down to T = 20 K and then a sublinear decrease λ(T ) ~ T 0.66(5) on cooling towardsmore » T = 4 K. In addition, the introduction of interstitial oxygen (δ = 0.1) is found to drastically affect the magnetism. For the fast-cooling experiment (>10 K/min), YBaCo 4O 7.1 enters a regime characterized by persistent spin dynamics below 90 K. For the slow-cooling experiment (1 K/min), evidence is obtained for the phase separation into interstitial oxygen-poor and oxygen-rich regions with distinct correlation times. The observed temperature, cooling rate, and oxygen content dependencies of spin dynamics are discussed in terms of a broad range of spin-spin correlation times, relying on a different degree of frustration between the kagome and triangle sublattices as well as of oxygen migration.« less

  18. Density Dependence and Growth Rate: Evolutionary Effects on Resistance Development to Bt (Bacillus thuringiensis).

    PubMed

    Martinez, Jeannette C; Caprio, Michael A; Friedenberg, Nicholas A

    2018-02-09

    It has long been recognized that pest population dynamics can affect the durability of a pesticide, but dose remains the primary component of insect resistance management (IRM). For transgenic pesticidal traits such as Bt (Bacillus thuringiensis Berliner (Bacillales: Bacillaceae)), dose (measured as the mortality of susceptibles caused by a toxin) is a relatively fixed characteristic and often falls below the standard definition of high dose. Hence, it is important to understand how pest population dynamics modify durability and what targets they present for IRM. We used a deterministic model of a generic arthropod pest to examine how timing and strength of density dependence interacted with population growth rate and Bt mortality to affect time to resistance. As in previous studies, durability typically reached a minimum at intermediate doses. However, high population growth rates could eliminate benefits of high dose. The timing of density dependence had a more subtle effect. If density dependence operated simultaneously with Bt mortality, durability was insensitive to its strengths. However, if density dependence was driven by postselection densities, decreasing its strength could increase durability. The strength of density dependence could affect durability of both single traits and pyramids, but its influence depended on the timing of density dependence and size of the refuge. Our findings suggest the utility of a broader definition of high dose, one that incorporates population-dynamic context. That maximum growth rates and timing and strength of interactions causing density dependent mortality can all affect durability, also highlights the need for ecologically integrated approaches to IRM research. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Pappas, Eleftherios P.; Zoros, Emmanouil; Moutsatsos, Argyris; Peppa, Vasiliki; Zourari, Kyveli; Karaiskos, Pantelis; Papagiannis, Panagiotis

    2017-05-01

    There is an acknowledged need for the design and implementation of physical phantoms appropriate for the experimental validation of model-based dose calculation algorithms (MBDCA) introduced recently in 192Ir brachytherapy treatment planning systems (TPS), and this work investigates whether it can be met. A PMMA phantom was prepared to accommodate material inhomogeneities (air and Teflon), four plastic brachytherapy catheters, as well as 84 LiF TLD dosimeters (MTS-100M 1  ×  1  ×  1 mm3 microcubes), two radiochromic films (Gafchromic EBT3) and a plastic 3D dosimeter (PRESAGE). An irradiation plan consisting of 53 source dwell positions was prepared on phantom CT images using a commercially available TPS and taking into account the calibration dose range of each detector. Irradiation was performed using an 192Ir high dose rate (HDR) source. Dose to medium in medium, Dmm , was calculated using the MBDCA option of the same TPS as well as Monte Carlo (MC) simulation with the MCNP code and a benchmarked methodology. Measured and calculated dose distributions were spatially registered and compared. The total standard (k  =  1) spatial uncertainties for TLD, film and PRESAGE were: 0.71, 1.58 and 2.55 mm. Corresponding percentage total dosimetric uncertainties were: 5.4-6.4, 2.5-6.4 and 4.85, owing mainly to the absorbed dose sensitivity correction and the relative energy dependence correction (position dependent) for TLD, the film sensitivity calibration (dose dependent) and the dependencies of PRESAGE sensitivity. Results imply a LiF over-response due to a relative intrinsic energy dependence between 192Ir and megavoltage calibration energies, and a dose rate dependence of PRESAGE sensitivity at low dose rates (<1 Gy min-1). Calculations were experimentally validated within uncertainties except for MBDCA results for points in the phantom periphery and dose levels  <20%. Experimental MBDCA validation is laborious, yet feasible. Further work is required for the full characterization of dosimeter response for 192Ir and the reduction of experimental uncertainties.

  20. Characterization of the Exradin W1 scintillator for use in radiotherapy.

    PubMed

    Carrasco, P; Jornet, N; Jordi, O; Lizondo, M; Latorre-Musoll, A; Eudaldo, T; Ruiz, A; Ribas, M

    2015-01-01

    To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. Exradin W1 showed a temperature dependence of -0.225% °C(-1). The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.

  1. Immunization Schedule

    MedlinePlus

    ... third dose may be needed, depending on the brand of vaccine used in previous Hib immunizations. PCV ... third dose may be needed, depending on the brand of vaccine used in previous RV immunizations. 6 ...

  2. A swinging seesaw as a novel model mechanism for time-dependent hormesis under dose-dependent stimulatory and inhibitory effects: A case study on the toxicity of antibacterial chemicals to Aliivibrio fischeri.

    PubMed

    Sun, Haoyu; Calabrese, Edward J; Zheng, Min; Wang, Dali; Pan, Yongzheng; Lin, Zhifen; Liu, Ying

    2018-08-01

    Hormesis occurs frequently in broadly ranging biological areas (e.g. plant biology, microbiology, biogerontology), toxicology, pharmacology and medicine. While numerous mechanisms (e.g. receptor and pathway mediated pathway responses) account for stimulatory and inhibitory features of hormetic dose responses, the vast majority emphasizes the inclusion of many doses but only one timepoint or use of a single optimized dose that is assessed over a broad range of timepoints. In this paper, a toxicity study was designed using a large number of properly spaced doses with responses determined over a large number of timepoints, which could help us reveal the underlying mechanism of hormesis. We present the results of a dose-time-response study on hormesis using five antibacterial chemicals on the bioluminescence of Aliivibrio fischeri, measuring expression of protein mRNA based on quorum sensing, simulating bioluminescent reaction and analyzing toxic actions of test chemicals. The findings show dose-time-dependent responses conforming to the hormetic dose-response model, while revealing unique response dynamics between agent induced stimulatory and inhibitory effects within bacterial growth phase dynamics. These dynamic dose-time features reveal a type of biological seesaw model that integrates stimulatory and inhibitory responses within unique growth phase, dose and time features, which has faultlessly explained the time-dependent hormetic phenomenon induced by five antibacterial chemicals (characterized by low-dose stimulation and high-dose inhibition). This study offers advances in understanding cellular dynamics, the biological integration of diverse and opposing responses and their role in evolutionary adaptive strategies to chemicals, which can provide new insight into the mechanistic investigation of hormesis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh

    2016-01-01

    Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed themore » dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late RILD are also due to different pathologies. As such, new radiation techniques reducing irradiated volume might change the dose-limiting toxicity of the radiation therapy treatment.« less

  4. Dose-Dependent Effects of Statins for Patients with Aneurysmal Subarachnoid Hemorrhage: Meta-Regression Analysis.

    PubMed

    To, Minh-Son; Prakash, Shivesh; Poonnoose, Santosh I; Bihari, Shailesh

    2018-05-01

    The study uses meta-regression analysis to quantify the dose-dependent effects of statin pharmacotherapy on vasospasm, delayed ischemic neurologic deficits (DIND), and mortality in aneurysmal subarachnoid hemorrhage. Prospective, retrospective observational studies, and randomized controlled trials (RCTs) were retrieved by a systematic database search. Summary estimates were expressed as absolute risk (AR) for a given statin dose or control (placebo). Meta-regression using inverse variance weighting and robust variance estimation was performed to assess the effect of statin dose on transformed AR in a random effects model. Dose-dependence of predicted AR with 95% confidence interval (CI) was recovered by using Miller's Freeman-Tukey inverse. The database search and study selection criteria yielded 18 studies (2594 patients) for analysis. These included 12 RCTs, 4 retrospective observational studies, and 2 prospective observational studies. Twelve studies investigated simvastatin, whereas the remaining studies investigated atorvastatin, pravastatin, or pitavastatin, with simvastatin-equivalent doses ranging from 20 to 80 mg. Meta-regression revealed dose-dependent reductions in Freeman-Tukey-transformed AR of vasospasm (slope coefficient -0.00404, 95% CI -0.00720 to -0.00087; P = 0.0321), DIND (slope coefficient -0.00316, 95% CI -0.00586 to -0.00047; P = 0.0392), and mortality (slope coefficient -0.00345, 95% CI -0.00623 to -0.00067; P = 0.0352). The present meta-regression provides weak evidence for dose-dependent reductions in vasospasm, DIND and mortality associated with acute statin use after aneurysmal subarachnoid hemorrhage. However, the analysis was limited by substantial heterogeneity among individual studies. Greater dosing strategies are a potential consideration for future RCTs. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Structator: fast index-based search for RNA sequence-structure patterns

    PubMed Central

    2011-01-01

    Background The secondary structure of RNA molecules is intimately related to their function and often more conserved than the sequence. Hence, the important task of searching databases for RNAs requires to match sequence-structure patterns. Unfortunately, current tools for this task have, in the best case, a running time that is only linear in the size of sequence databases. Furthermore, established index data structures for fast sequence matching, like suffix trees or arrays, cannot benefit from the complementarity constraints introduced by the secondary structure of RNAs. Results We present a novel method and readily applicable software for time efficient matching of RNA sequence-structure patterns in sequence databases. Our approach is based on affix arrays, a recently introduced index data structure, preprocessed from the target database. Affix arrays support bidirectional pattern search, which is required for efficiently handling the structural constraints of the pattern. Structural patterns like stem-loops can be matched inside out, such that the loop region is matched first and then the pairing bases on the boundaries are matched consecutively. This allows to exploit base pairing information for search space reduction and leads to an expected running time that is sublinear in the size of the sequence database. The incorporation of a new chaining approach in the search of RNA sequence-structure patterns enables the description of molecules folding into complex secondary structures with multiple ordered patterns. The chaining approach removes spurious matches from the set of intermediate results, in particular of patterns with little specificity. In benchmark experiments on the Rfam database, our method runs up to two orders of magnitude faster than previous methods. Conclusions The presented method's sublinear expected running time makes it well suited for RNA sequence-structure pattern matching in large sequence databases. RNA molecules containing several stem-loop substructures can be described by multiple sequence-structure patterns and their matches are efficiently handled by a novel chaining method. Beyond our algorithmic contributions, we provide with Structator a complete and robust open-source software solution for index-based search of RNA sequence-structure patterns. The Structator software is available at http://www.zbh.uni-hamburg.de/Structator. PMID:21619640

  6. Dosimetric impact of the low-dose envelope of scanned proton beams at a ProBeam facility: comparison of measurements with TPS and MC calculations.

    PubMed

    Würl, M; Englbrecht, F; Parodi, K; Hillbrand, M

    2016-01-21

    Due to the low-dose envelope of scanned proton beams, the dose output depends on the size of the irradiated field or volume. While this field size dependence has already been extensively investigated by measurements and Monte Carlo (MC) simulations for single pencil beams or monoenergetic fields, reports on the relevance of this effect for analytical dose calculation models are limited. Previous studies on this topic only exist for specific beamline designs. However, the amount of large-angle scattered primary and long-range secondary particles and thus the relevance of the low-dose envelope can considerably be influenced by the particular design of the treatment nozzle. In this work, we therefore addressed the field size dependence of the dose output at the commercially available ProBeam(®) beamline, which is being built in several facilities worldwide. We compared treatment planning dose calculations with ionization chamber (IC) measurements and MC simulations, using an experimentally validated FLUKA MC model of the scanning beamline. To this aim, monoenergetic square fields of three energies, as well as spherical target volumes were studied, including the investigation on the influence of the lateral spot spacing on the field size dependence. For the spherical target volumes, MC as well as analytical dose calculation were found in excellent agreement with the measurements in the center of the spread-out Bragg peak. In the plateau region, the treatment planning system (TPS) tended to overestimate the dose compared to MC calculations and IC measurements by up to almost 5% for the smallest investigated sphere and for small monoenergetic square fields. Narrower spot spacing slightly enhanced the field size dependence of the dose output. The deviations in the plateau dose were found to go in the clinically safe direction, i.e. the actual deposited dose outside the target was found to be lower than predicted by the TPS. Thus, the moderate overestimation of dose to normal tissue by the TPS is likely to result in no severe consequences in clinical cases, even for the most critical cases of small target volumes.

  7. Thermoluminescent dosimetry in electron beams: energy dependence.

    PubMed

    Robar, V; Zankowski, C; Olivares Pla, M; Podgorsak, E B

    1996-05-01

    The response of thermoluminescent dosimeters to electron irradiations depends on the radiation dose, mean electron energy at the position of the dosimeter in phantom, and the size of the dosimeter. In this paper the semi-empirical expression proposed by Holt et al. [Phys. Med. Biol. 20, 559-570 (1975)] is combined with the calculated electron dose fraction to determine the thermoluminescent dosimetry (TLD) response as a function of the mean electron energy and the dosimeter size. The electron and photon dose fractions, defined as the relative contributions of electrons and bremsstrahlung photons to the total dose for a clinical electron beam, are calculated with Monte Carlo techniques using EGS4. Agreement between the calculated and measured TLD response is very good. We show that the considerable reduction in TLD response per unit dose at low electron energies, i.e., at large depths in phantom, is offset by an ever-increasing relative contribution of bremsstrahlung photons to the total dose of clinical electron beams. This renders the TLD sufficiently reliable for dose measurements over the entire electron depth dose distribution despite the dependence of the TLD response on electron beam energy.

  8. Pharmacologically active phenylpropanoids from Senra incana.

    PubMed

    Farah, M H; Samuelsson, G

    1992-02-01

    Coniferaldehyde, scopoletin, sinapaldehyde, and syringaldehyde were isolated from an aqueous extract of Senra incana. All four compounds inhibited prostaglandin synthetase in a dose-dependent way. Compared to aspirin, the potency of coniferaldehyde and scopoletin was about five times higher, whereas syringaldehyde and sinapaldehyde had about half the potency of this reference compound. On topical application, sinapaldehyde and scopoletin dose-dependently inhibited ethyl phenylpropiolate-induced edema of the rat ear. The active dose range was 1-10 micrograms/ear. Higher doses had a lower effect. Syringaldehyde was active in the range 20-100 micrograms/ear, whereas the effect of coniferaldehyde was inconclusive. Coniferaldehyde and sinapaldehyde inhibited electrically induced contractions of the guinea pig ileum in a dose-dependent way. Syringaldehyde showed a weak inhibition at a concentration of 550 microM.

  9. High-dose baclofen for the treatment of alcohol dependence (BACLAD study): a randomized, placebo-controlled trial.

    PubMed

    Müller, Christian A; Geisel, Olga; Pelz, Patricia; Higl, Verena; Krüger, Josephine; Stickel, Anna; Beck, Anne; Wernecke, Klaus-Dieter; Hellweg, Rainer; Heinz, Andreas

    2015-08-01

    Previous randomized, placebo-controlled trials (RCTs) assessing the efficacy of the selective γ-aminobutyric acid (GABA)-B receptor agonist baclofen in the treatment of alcohol dependence have reported divergent results, possibly related to the low to medium dosages of baclofen used in these studies (30-80mg/d). Based on preclinical observations of a dose-dependent effect and positive case reports in alcohol-dependent patients, the present RCT aimed to assess the efficacy and safety of individually titrated high-dose baclofen for the treatment of alcohol dependence. Out of 93 alcohol-dependent patients initially screened, 56 were randomly assigned to a double-blind treatment with individually titrated baclofen or placebo using dosages of 30-270mg/d. The multiple primary outcome measures were (1) total abstinence and (2) cumulative abstinence duration during a 12-week high-dose phase. More patients of the baclofen group maintained total abstinence during the high-dose phase than those receiving placebo (15/22, 68.2% vs. 5/21, 23.8%, p=0.014). Cumulative abstinence duration was significantly higher in patients given baclofen compared to patients of the placebo group (mean 67.8 (SD 30) vs. 51.8 (SD 29.6) days, p=0.047). No drug-related serious adverse events were observed during the trial. Individually titrated high-dose baclofen effectively supported alcohol-dependent patients in maintaining alcohol abstinence and showed a high tolerability, even in the event of relapse. These results provide further evidence for the potential of baclofen, thereby possibly extending the current pharmacological treatment options in alcohol dependence. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  10. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    PubMed Central

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  11. Plasma growth hormone (GH), insulin and amino acid responses to arginine with or without aspartic acid in pigs. Effect of the dose.

    PubMed

    Cochard, A; Guilhermet, R; Bonneau, M

    1998-01-01

    The aim of the present study was to examine, for the first time in pigs, the dose-dependent effect of arginine (ARG) on growth hormone (GH) and insulin release and the effect of the combined ARG and aspartic acid (ASP) treatment on GH and insulin release. ARG (0.5 or 1 g/kg body weight) with or without an equimolar supplement of ASP (0.38 or 0.76 g/kg, respectively) was administered in piglets via the duodenum. ARG increased plasma arginine, ornithine, urea, proline and branched chain amino acid concentrations. ASP increased specifically plasma aspartic acid, glutamic acid, alanine and citrulline concentrations. Plasma insulin increased with no apparent difference between treatments. Maximum GH level and the area under the GH curve (AUC) were increased in a dose-dependent manner in response to ARG treatment. GH response to the combined ARG and ASP treatment (ARGASP) was delayed compared to ARG alone and was not dose-dependent. AUC for GH after ARGASP treatments were intermediate between those observed after the two ARG doses. Our data suggest that high ASP doses transiently inhibit and delay ARG-induced GH release in pigs and that an equimolar supplement of ASP stimulates or inhibits ARG-induced GH release depending on the dose used.

  12. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.

    PubMed

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-12-07

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations.

  13. Repair-dependent cell radiation survival and transformation: an integrated theory.

    PubMed

    Sutherland, John C

    2014-09-07

    The repair-dependent model of cell radiation survival is extended to include radiation-induced transformations. The probability of transformation is presumed to scale with the number of potentially lethal damages that are repaired in a surviving cell or the interactions of such damages. The theory predicts that at doses corresponding to high survival, the transformation frequency is the sum of simple polynomial functions of dose; linear, quadratic, etc, essentially as described in widely used linear-quadratic expressions. At high doses, corresponding to low survival, the ratio of transformed to surviving cells asymptotically approaches an upper limit. The low dose fundamental- and high dose plateau domains are separated by a downwardly concave transition region. Published transformation data for mammalian cells show the high-dose plateaus predicted by the repair-dependent model for both ultraviolet and ionizing radiation. For the neoplastic transformation experiments that were analyzed, the data can be fit with only the repair-dependent quadratic function. At low doses, the transformation frequency is strictly quadratic, but becomes sigmodial over a wider range of doses. Inclusion of data from the transition region in a traditional linear-quadratic analysis of neoplastic transformation frequency data can exaggerate the magnitude of, or create the appearance of, a linear component. Quantitative analysis of survival and transformation data shows good agreement for ultraviolet radiation; the shapes of the transformation components can be predicted from survival data. For ionizing radiations, both neutrons and x-rays, survival data overestimate the transforming ability for low to moderate doses. The presumed cause of this difference is that, unlike UV photons, a single x-ray or neutron may generate more than one lethal damage in a cell, so the distribution of such damages in the population is not accurately described by Poisson statistics. However, the complete sigmodial dose-response data for neoplastic transformations can be fit using the repair-dependent functions with all parameters determined only from transformation frequency data.

  14. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    PubMed

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low.

  15. MPI Runtime Error Detection with MUST: Advances in Deadlock Detection

    DOE PAGES

    Hilbrich, Tobias; Protze, Joachim; Schulz, Martin; ...

    2013-01-01

    The widely used Message Passing Interface (MPI) is complex and rich. As a result, application developers require automated tools to avoid and to detect MPI programming errors. We present the Marmot Umpire Scalable Tool (MUST) that detects such errors with significantly increased scalability. We present improvements to our graph-based deadlock detection approach for MPI, which cover future MPI extensions. Our enhancements also check complex MPI constructs that no previous graph-based detection approach handled correctly. Finally, we present optimizations for the processing of MPI operations that reduce runtime deadlock detection overheads. Existing approaches often require ( p ) analysis time permore » MPI operation, for p processes. We empirically observe that our improvements lead to sub-linear or better analysis time per operation for a wide range of real world applications.« less

  16. Multichannel film dosimetry with nonuniformity correction.

    PubMed

    Micke, Andre; Lewis, David F; Yu, Xiang

    2011-05-01

    A new method to evaluate radiochromic film dosimetry data scanned in multiple color channels is presented. This work was undertaken to demonstrate that the multichannel method is fundamentally superior to the traditional single channel method. The multichannel method allows for the separation and removal of the nondose-dependent portions of a film image leaving a residual image that is dependent only on absorbed dose. Radiochromic films were exposed to 10 x 10 cm radiation fields (Co-60 and 6 MV) at doses up to about 300 cGy. The films were scanned in red-blue-green (RGB) format on a flatbed color scanner and measured to build calibration tables relating the absorbed dose to the response of the film in each of the color channels. Film images were converted to dose maps using two methods. The first method used the response from a single color channel and the second method used the response from all three color channels. The multichannel method allows for the separation of the scanned signal into one part that is dose-dependent and another part that is dose-independent and enables the correction of a variety of disturbances in the digitized image including nonuniformities in the active coating on the radiochromic film as well as scanner related artifacts. The fundamental mathematics of the two methods is described and the dose maps calculated from film images using the two methods are compared and analyzed. The multichannel dosimetry method was shown to be an effective way to separate out non-dose-dependent abnormalities from radiochromic dosimetry film images. The process was shown to remove disturbances in the scanned images caused by nonhomogeneity of the radiochromic film and artifacts caused by the scanner and to improve the integrity of the dose information. Multichannel dosimetry also reduces random noise in the dose images and mitigates scanner-related artifacts such as lateral position dependence. In providing an ability to calculate dose maps from data in all the color channels the multichannel method provides the ability to examine the agreement between the color channels. Furthermore, when using calibration data to convert RGB film images to dose using the new method, poor correspondence between the dose calculations for the three color channels provides an important indication that the this new technique enables easy indication in case the dose and calibration films are curve mismatched. The method permit compensation for thickness nonuniformities in the film, increases the signal to noise level, mitigates the lateral dose-dependency of flatbed scanners effect of the calculated dose map and extends the evaluable dose range to 10 cGy-100 Gy. Multichannel dosimetry with radiochromic film like Gafchromic EBT2 is shown to have significant advantages over single channel dosimetry. It is recommended that the dosimetry protocols described be implemented when using this radiochromic film to ensure the best data integrity and dosimetric accuracy.

  17. Acute ethanol ingestion produces dose-dependent effects on motor behavior in the honey bee (Apis mellifera).

    PubMed

    Maze, Ian S; Wright, Geraldine A; Mustard, Julie A

    2006-01-01

    Ethanol consumption produces characteristic behavioral states in animals that include sedation, disorientation, and disruption of motor function. Using individual honey bees, we assessed the effects of ethanol ingestion on motor function via continuous observations of their behavior. Consumption of 1 M sucrose solutions containing a range of ethanol doses led to hemolymph ethanol levels of approximately 40-100 mM. Using ethanol doses in this range, we observed time and dose-dependent effects of ethanol on the percent of time our subjects spent walking, stopped, or upside down, and on the duration and frequency of bouts of behavior. The effects on grooming and flying behavior were more complex. Behavioral recovery from ethanol treatment was both time and ethanol dose dependent, occurring between 12 and 24 h post-ingestion for low doses and at 24-48 h for higher doses. Furthermore, the amount of ethanol measured in honey bee hemolymph appeared to correlate with recovery. We predict that the honey bee will prove to be an excellent model system for studying the influence of ethanol on the neural mechanisms underlying behavior.

  18. Cross-sectional and prospective relation of cannabis potency, dosing and smoking behaviour with cannabis dependence: an ecological study.

    PubMed

    van der Pol, Peggy; Liebregts, Nienke; Brunt, Tibor; van Amsterdam, Jan; de Graaf, Ron; Korf, Dirk J; van den Brink, Wim; van Laar, Margriet

    2014-07-01

    Increased delta-9-tetrahydrocannabinol (THC) concentrations in cannabis may lead to higher THC exposure, cannabis dependence and treatment need, but users may also adapt the actual intake of THC through reduced inhalation of THC containing smoke (titration). We investigated whether consumers of stronger cannabis use less cannabis per joint or inhale less smoke than those using less potent cannabis and whether these factors predict cannabis dependence severity. Heavy cannabis users (n = 98) brought their own cannabis, rolled a joint and smoked it ad libitum in a naturalistic setting. We analysed the content of the joint, its association with smoking behaviour and the cross-sectional and prospective (1.5-year follow-up) relations between smoking behaviour and cannabis dependence severity (total number of DSM-IV dependence symptoms). THC concentration in cannabis (range 1.10-24.70%) was correlated positively with cannabis dose per joint (b = 0.008, P = 0.01), but the resulting THC concentration per joint (range 0.24-15.72%) was associated negatively with inhalation volume (b = -0.05, P = 0.03). Smoking behaviour measures (number of puffs, inhaled volume, reduction of puff volume and puff duration while smoking) predicted follow-up dependence severity, independently of baseline dependence severity and monthly THC dose (number of joints × cannabis dose × cannabis THC concentration). Monthly THC dose only predicted follow-up dependence severity when unadjusted for baseline severity. Cannabis users titrate their delta-9-tetrahydrocannabinol intake by inhaling lower volumes of smoke when smoking strong joints, but this does not fully compensate for the higher cannabis doses per joint when using strong cannabis. Thus, users of more potent cannabis are generally exposed to more delta-9-tetrahydrocannabinol. Smoking behaviour appears to be a stronger predictor for cannabis dependence severity than monthly delta-9-tetrahydrocannabinol dose. © 2014 Society for the Study of Addiction.

  19. The dose-effect relationship of baclofen in alcohol dependence: A 1-year cohort study.

    PubMed

    Pignon, Baptiste; Labreuche, Julien; Auffret, Marine; Gautier, Sophie; Deheul, Sylvie; Simioni, Nicolas; Cottencin, Olivier; Bordet, Régis; Duhamel, Alain; Rolland, Benjamin

    2017-07-01

    Our aim is to study the relationship between dose of baclofen and effectiveness in alcohol dependence. Two hundred two patients with alcohol dependence, who received baclofen treatment for drinking reduction, were followed up for 1 year. For each patient-month of treatment, the maximum daily dose of baclofen (DDB) and average weekly alcohol consumption (AWAC) were calculated. We defined a favorable drinking outcome as an AWAC under 200 g/w for at least 2 consecutive months. We divided the DDB of each patient-month into 3 categories (low dose: <90 mg/d, medium dose: 90-150 mg/d, and high dose: >150 mg/d) and investigated the relationship between reaching a favorable outcome and the concurrent DDB category in a time-varying Cox regression analysis. Hazard ratios (HRs) were adjusted based on age, sex, and initial AWAC. One hundred forty subjects were followed during at least 1 month. Of these patients, 58 (41%) had a favorable drinking outcome. In comparison to low dose, medium dose was associated with a decreased rate of favorable drinking outcome (HR = 0.42; 95% CI [0.20, 0.88]), whereas no difference was found with high dose (HR = 1.31; 95% CI [0.65, 2.64]). The relationship between dose of baclofen and favorable drinking outcome was U-shaped, that is, was increased at low and high doses compared to medium doses. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Intravenous Nicotine Self-Administration in Smokers: Dose-Response Function and Sex Differences.

    PubMed

    Jensen, Kevin P; DeVito, Elise E; Valentine, Gerald; Gueorguieva, Ralitza; Sofuoglu, Mehmet

    2016-07-01

    Sex differences in the sensitivity to nicotine may influence vulnerability to tobacco dependence. The goal of this study was to investigate the dose-response function for the reinforcing and subjective effects of intravenous nicotine in male and female smokers. Tobacco-dependent subjects (12 male and 14 female) participated in four experimental sessions in which they received sample infusions of saline and nicotine (0.1, 0.2, 0.3, or 0.4 mg doses) in a randomized double-blind crossover design. During each session, subjects first received the sample infusions, and heart rate (HR), blood pressure, and subjective stimulatory, pleasurable and aversive responses were monitored. Immediately following the sample infusions, subjects self-administered either nicotine or saline in six double-blind forced-choice trials. A sex by dose interaction was observed in the nicotine choice paradigm. Nicotine self-administration rate was negatively correlated with nicotine dose in males (males displayed choice preference for low doses of nicotine over high doses of nicotine), but no significant relationship between dose and choice preference was evident in females. Relative to placebo, sample doses of nicotine increased heart rate and blood pressure, and induced stimulatory, pleasurable, and aversive subjective effects. Diastolic blood pressure increased dose dependently in males, but not in females. These findings, which demonstrate sex differences in nicotine self-administration for doses that are near to the reinforcement threshold, suggest that male and female smokers may respond differently to the changes in nicotine doses available for self-administration.

  1. Blockade of hyperpolarizing currents produces a dose-dependent effect on heart rate.

    PubMed

    Ziyatdinova, N I; Giniatullin, R A; Svyatova, N V; Zefirov, T L

    2001-03-01

    Intravenous injection of ZD 7288, a new specific hyperpolarizing current blocker, dose-dependently reduces heart rate in adult rats. The autonomic nervous system modulates changes in heart rate caused by hyperpolarizing currents.

  2. Evaluation of ameliorative potential of supranutritional selenium on enrofloxacin-induced testicular toxicity.

    PubMed

    Rungsung, Soya; Khan, Adil Mehraj; Sood, Naresh Kumar; Rampal, Satyavan; Singh Saini, Simrat Pal

    2016-05-25

    The study was designed to assess the ameliorative potential of selenium (Se) on enrofloxacin-induced testicular toxicity in rats. There was a significant decrease in body weight and non-significant decrease in mean testicular weight of enrofloxacin treated rats. In enrofloxacin treated rats, total sperm count and viability decreased where as sperm abnormalities increased. Testicular histopathology revealed dose dependent dysregulation of spermatogenesis and presence of necrotic debris in seminiferous tubules which was marginally improved with Se. Enrofloxacin also produced a dose dependent decrease in testosterone level. The activity of testicular antioxidant enzymes decreased where as lipid peroxidation increased in a dose-dependent manner. Se supplementation partially restored oxidative stress and sperm damage and did not affect the plasma concentrations of enrofloxacin or ciprofloxacain. The results indicate that enrofloxacin produces a dose-dependent testicular toxicity in rats that is moderately ameliorated with supranutritional Se. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. [Dose rate-dependent cellular and molecular effects of ionizing radiation].

    PubMed

    Przybyszewski, Waldemar M; Wideł, Maria; Szurko, Agnieszka; Maniakowski, Zbigniew

    2008-09-11

    The aim of radiation therapy is to kill tumor cells while minimizing damage to normal cells. The ultimate effect of radiation can be apoptotic or necrotic cell death as well as cytogenetic damage resulting in genetic instability and/or cell death. The destructive effects of radiation arise from direct and indirect ionization events leading to peroxidation of macromolecules, especially those present in lipid-rich membrane structures as well as chromatin lipids. Lipid peroxidative end-products may damage DNA and proteins. A characteristic feature of radiation-induced peroxidation is an inverse dose-rate effect (IDRE), defined as an increase in the degree of oxidation(at constant absorbed dose) accompanying a lower dose rate. On the other hand, a low dose rate can lead to the accumulation of cells in G2, the radiosensitive phase of the cell cycle since cell cycle control points are not sensitive to low dose rates. Radiation dose rate may potentially be the main factor improving radiotherapy efficacy as well as affecting the intensity of normal tissue and whole-body side effects. A better understanding of dose rate-dependent biological effects may lead to improved therapeutic intervention and limit normal tissue reaction. The study reviews basic biological effects that depend on the dose rate of ionizing radiation.

  4. Dose-dependent model of caffeine effects on human vigilance during total sleep deprivation.

    PubMed

    Ramakrishnan, Sridhar; Laxminarayan, Srinivas; Wesensten, Nancy J; Kamimori, Gary H; Balkin, Thomas J; Reifman, Jaques

    2014-10-07

    Caffeine is the most widely consumed stimulant to counter sleep-loss effects. While the pharmacokinetics of caffeine in the body is well-understood, its alertness-restoring effects are still not well characterized. In fact, mathematical models capable of predicting the effects of varying doses of caffeine on objective measures of vigilance are not available. In this paper, we describe a phenomenological model of the dose-dependent effects of caffeine on psychomotor vigilance task (PVT) performance of sleep-deprived subjects. We used the two-process model of sleep regulation to quantify performance during sleep loss in the absence of caffeine and a dose-dependent multiplier factor derived from the Hill equation to model the effects of single and repeated caffeine doses. We developed and validated the model fits and predictions on PVT lapse (number of reaction times exceeding 500 ms) data from two separate laboratory studies. At the population-average level, the model captured the effects of a range of caffeine doses (50-300 mg), yielding up to a 90% improvement over the two-process model. Individual-specific caffeine models, on average, predicted the effects up to 23% better than population-average caffeine models. The proposed model serves as a useful tool for predicting the dose-dependent effects of caffeine on the PVT performance of sleep-deprived subjects and, therefore, can be used for determining caffeine doses that optimize the timing and duration of peak performance. Published by Elsevier Ltd.

  5. Dosimetric characterization of a synthetic single crystal diamond detector in a clinical 62 MeV ocular therapy proton beam

    NASA Astrophysics Data System (ADS)

    Marinelli, Marco; Pompili, F.; Prestopino, G.; Verona, C.; Verona-Rinati, G.; Cirrone, G. A. P.; Cuttone, G.; La Rosa, R. M.; Raffaele, L.; Romano, F.; Tuvè, C.

    2014-12-01

    A synthetic single crystal diamond based Schottky photodiode was tested at INFN-LNS on the proton beam line (62 MeV) dedicated to the radiation treatment of ocular disease. The diamond detector response was studied in terms of pre-irradiation dose, linearity with dose and dose rate, and angular dependence. Depth dose curves were measured for the 62 MeV pristine proton beam and for three unmodulated range-shifted proton beams; furthermore, the spread-out Bragg peak was measured for a modulated therapeutic proton beam. Beam parameters, recommended by the ICRU report 78, were evaluated to analyze depth-dose curves from diamond detector. Measured dose distributions were compared with the corresponding dose distributions acquired with reference plane-parallel ionization chambers. Field size dependence of the output factor (dose per monitor unit) in a therapeutic modulated proton beam was measured with the diamond detector over the range of ocular proton therapy collimator diameters (5-30 mm). Output factors measured with the diamond detector were compared to the ones by a Markus ionization chamber, a Scanditronix Hi-p Si stereotactic diode and a radiochromic EBT2 film. Signal stability within 0.5% was demonstrated for the diamond detector with no need of any pre-irradiation dose. Dose and dose rate dependence of the diamond response was measured: deviations from linearity resulted to be within ±0.5% over the investigated ranges of 0.5-40.0 Gy and 0.3-30.0 Gy/min respectively. Output factors from diamond detector measured with the smallest collimator (5 mm in diameter) showed a maximum deviation of about 3% with respect to the high resolution radiochromic EBT2 film. Depth-dose curves measured by diamond for unmodulated and modulated beams were in good agreement with those from the reference plane-parallel Markus chamber, with relative differences lower than ±1% in peak-to-plateau ratios, well within experimental uncertainties. A 2.5% variation in diamond detector response was observed in angular dependence measurements carried-out by varying the proton beam incidence angle in the polar direction. The dosimetric characterization of the tested synthetic single crystal diamond detector clearly indicates its suitability for relative dosimetry in ocular therapy proton beams, with no need of any correction factors accounting for dose rate and linear energy transfer dependence.

  6. Rational design of an improved tissue-engineered vascular graft: determining the optimal cell dose and incubation time.

    PubMed

    Lee, Yong-Ung; Mahler, Nathan; Best, Cameron A; Tara, Shuhei; Sugiura, Tadahisa; Lee, Avione Y; Yi, Tai; Hibino, Narutoshi; Shinoka, Toshiharu; Breuer, Christopher

    2016-03-01

    We investigated the effect of cell seeding dose and incubation time on tissue-engineered vascular graft (TEVG) patency. Various doses of bone marrow-derived mononuclear cells (BM-MNCs) were seeded onto TEVGs, incubated for 0 or 12 h, and implanted in C57BL/6 mice. Different doses of human BM-MNCs were seeded onto TEVGs and measured for cell attachment. The incubation time showed no significant effect on TEVG patency. However, TEVG patency was significantly increased in a dose-dependent manner. In the human graft, more bone marrow used for seeding resulted in increased cell attachment in a dose-dependent manner. Increasing the BM-MNC dose and reducing incubation time is a viable strategy for improving the performance and utility of the graft.

  7. Characterization and prediction of monomer-based dose rate effects in electron-beam polymerization

    NASA Astrophysics Data System (ADS)

    Schissel, Sage M.; Lapin, Stephen C.; Jessop, Julie L. P.

    2017-12-01

    Properties of some materials produced by electron-beam (EB) induced polymerization appear dependent upon the rate at which the initiating dose was delivered. However, the magnitude of these dose rate effects (DREs) can vary greatly with different monomer formulations, suggesting DREs are dependent on chemical structure. The relationship among dose, dose rate, conversion, and the glass transition temperature (Tg) of the cured material was explored for an acrylate monomer series. A strong correlation was determined between the DRE magnitude and monomer size, and this correlation may be attributed to chain transfer. Using the Tg shift caused by changes in dose, a preliminary predictive relationship was developed to estimate the magnitude of the Tg DRE, enabling scale-up of process variables for polymers prone to dose rate effects.

  8. Mutations induced in Tradescantia by small doses of X-rays and neutrons - Analysis of dose-response curves.

    NASA Technical Reports Server (NTRS)

    Sparrow, A. H.; Underbrink, A. G.; Rossi, H. H.

    1972-01-01

    Dose-response curves for pink somatic mutations in Tradescantia stamen hairs were analyzed after neutron and X-ray irradiation with doses ranging from a fraction of a rad to the region of saturation. The dose-effect relation for neutrons indicates a linear dependence from 0.01 to 8 rads; between 0.25 and 5 rads, a linear dependence is indicated for X-rays also. As a consequence the relative biological effectiveness reaches a constant value (about 50) at low doses. The observations are in good agreement with the predictions of the theory of dual radiation action and support its interpretation of the effects of radiation on higher organisms. The doubling dose of X-rays was found to be nearly 1 rad.

  9. Life-stage-, sex-, and dose-dependent dietary toxicokinetics and relationship to toxicity of 2,4-dichlorophenoxyacetic acid (2,4-D) in rats: implications for toxicity test dose selection, design, and interpretation.

    PubMed

    Saghir, Shakil A; Marty, Mary S; Zablotny, Carol L; Passage, Julie K; Perala, Adam W; Neal, Barbara H; Hammond, Larry; Bus, James S

    2013-12-01

    Life-stage-dependent toxicity and dose-dependent toxicokinetics (TK) were evaluated in Sprague Dawley rats following dietary exposure to 2,4-dichlorophenoxyacetic acid (2,4-D). 2,4-D renal clearance is impacted by dose-dependent saturation of the renal organic anion transporter; thus, this study focused on identifying inflection points of onset of dietary nonlinear TK to inform dose selection decisions for toxicity studies. Male and female rats were fed 2,4-D-fortified diets at doses to 1600 ppm for 4-weeks premating, <2 weeks during mating, and to test day (TD) 71 to parental (P1) males and to P1 females through gestation/lactation to TD 96. F1 offspring were exposed via milk with continuing diet exposure until postnatal day (PND) 35. As assessed by plasma area under the curve for the time-course plasma concentration, nonlinear TK was observed ≥ 1200 ppm (63 mg/kg/day) for P1 males and between 200 and 400 ppm (14-27 mg/kg/day) for P1 females. Dam milk and pup plasma levels were higher on lactation day (LD) 14 than LD 4. Relative to P1 adults, 2,4-D levels were higher in dams during late gestation/lactation and postweaning pups (PND 21-35) and coincided with elevated intake of diet/kg body weight. Using conventional maximum tolerated dose (MTD) criteria based on body weight changes for dose selection would have resulted in excessive top doses approximately 2-fold higher than those identified incorporating critical TK data. These data indicate that demonstration of nonlinear TK, if present at dose levels substantially above real-world human exposures, is a key dose selection consideration for improving the human relevance of toxicity studies compared with studies employing conventional MTD dose selection strategies.

  10. Life-Stage-, Sex-, and Dose-Dependent Dietary Toxicokinetics and Relationship to Toxicity of 2,4-Dichlorophenoxyacetic Acid (2,4-D) in Rats: Implications for Toxicity Test Dose Selection, Design, and Interpretation

    PubMed Central

    Marty, Mary S.

    2013-01-01

    Life-stage-dependent toxicity and dose-dependent toxicokinetics (TK) were evaluated in Sprague Dawley rats following dietary exposure to 2,4-dichlorophenoxyacetic acid (2,4-D). 2,4-D renal clearance is impacted by dose-dependent saturation of the renal organic anion transporter; thus, this study focused on identifying inflection points of onset of dietary nonlinear TK to inform dose selection decisions for toxicity studies. Male and female rats were fed 2,4-D-fortified diets at doses to 1600 ppm for 4-weeks premating, <2 weeks during mating, and to test day (TD) 71 to parental (P1) males and to P1 females through gestation/lactation to TD 96. F1 offspring were exposed via milk with continuing diet exposure until postnatal day (PND) 35. As assessed by plasma area under the curve for the time-course plasma concentration, nonlinear TK was observed ≥1200 ppm (63mg/kg/day) for P1 males and between 200 and 400 ppm (14–27mg/kg/day) for P1 females. Dam milk and pup plasma levels were higher on lactation day (LD) 14 than LD 4. Relative to P1 adults, 2,4-D levels were higher in dams during late gestation/lactation and postweaning pups (PND 21–35) and coincided with elevated intake of diet/kg body weight. Using conventional maximum tolerated dose (MTD) criteria based on body weight changes for dose selection would have resulted in excessive top doses approximately 2-fold higher than those identified incorporating critical TK data. These data indicate that demonstration of nonlinear TK, if present at dose levels substantially above real-world human exposures, is a key dose selection consideration for improving the human relevance of toxicity studies compared with studies employing conventional MTD dose selection strategies. PMID:24105888

  11. Inhibition of gamma-radiation induced DNA damage in plasmid pBR322 by TMG, a water-soluble derivative of vitamin E.

    PubMed

    Rajagopalan, Rema; Wani, Khalida; Huilgol, Nagaraj G; Kagiya, Tsutomu V; Nair, Cherupally K Krishnan

    2002-06-01

    Alpha-tocopherol monoglucoside (TMG), a water-soluble derivative of alpha-tocopherol, has been examined for its ability to protect DNA against radiation-induced strand breaks. Gamma radiation, up to a dose of 6 Gy (dose rate, 0.7 Gy/minute), induced a dose-dependent increase in single strand breaks (SSBs) in plasmid pBR322 DNA. TMG inhibited the formation of gamma-radiation induced DNA single strand breaks (SSBs) in a concentration-dependent manner; 500 microM of TMG protected the single strand breaks completely. It also protected thymine glycol formation induced by gamma-radiation in a dose-dependent manner, based on an estimation of thymine glycol by HPLC.

  12. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    PubMed

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  13. Evaluation of the dependence of the exposure dose on the attenuation correction in brain PET/CT scans using 18F-FDG

    NASA Astrophysics Data System (ADS)

    Choi, Eun-Jin; Jeong, Moon-Taeg; Jang, Seong-Joo; Choi, Nam-Gil; Han, Jae-Bok; Yang, Nam-Hee; Dong, Kyung-Rae; Chung, Woon-Kwan; Lee, Yun-Jong; Ryu, Young-Hwan; Choi, Sung-Hyun; Seong, Kyeong-Jeong

    2014-01-01

    This study examined whether scanning could be performed with minimum dose and minimum exposure to the patient after an attenuation correction. A Hoffman 3D Brain Phantom was used in BIO_40 and D_690 PET/CT scanners, and the CT dose for the equipment was classified as a low dose (minimum dose), medium dose (general dose for scanning) and high dose (dose with use of contrast medium) before obtaining the image at a fixed kilo-voltage-peak (kVp) and milliampere (mA) that were adjusted gradually in 17-20 stages. A PET image was then obtained to perform an attenuation correction based on an attenuation map before analyzing the dose difference. Depending on tube current in the range of 33-190 milliampere-second (mAs) when BIO_40 was used, a significant difference in the effective dose was observed between the minimum and the maximum mAs (p < 0.05). According to a Scheffe post-hoc test, the ratio of the minimum to the maximum of the effective dose was increased by approximately 5.26-fold. Depending on the change in the tube current in the range of 10-200 mA when D_690 was used, a significant difference in the effective dose was observed between the minimum and the maximum of mA (p < 0.05). The Scheffe posthoc test revealed a 20.5-fold difference. In conclusion, because effective exposure dose increases with increasing operating current, it is possible to reduce the exposure limit in a brain scan can be reduced if the CT dose can be minimized for a transmission scan.

  14. Benzodiazepine sensitivity in normal human subjects.

    PubMed

    Hommer, D W; Matsuo, V; Wolkowitz, O; Chrousos, G; Greenblatt, D J; Weingartner, H; Paul, S M

    1986-06-01

    Increasing intravenous doses of diazepam or placebo were administered to ten healthy normal volunteers, and the changes in saccadic eye velocity, self-rated sedation and anxiety, and plasma cortisol and growth hormone concentrations were measured. Diazepam administration (4.4 to 140 micrograms/kg, cumulative dose) resulted in a dose-dependent decrease in saccadic eye velocity and plasma cortisol level as well as a dose-dependent increase in self-rated sedation and plasma growth hormone level. Self-rated anxiety was unaffected in these relatively nonanxious subjects. The diazepam-induced changes in saccadic eye velocity, sedation, and growth hormone and cortisol levels were highly correlated with each other and with increasing plasma diazepam concentration. These results are consistent with a benzodiazepine receptor-mediated action of diazepam. The highly quantifiable and dose-dependent decrease in saccadic eye velocity by benzodiazepines should make this a useful measure of benzodiazepine receptor sensitivity in humans.

  15. Reproducibility of CVD diamond detectors for radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Betzel, G. T.; Lansley, S. P.; McKay, D.; Meyer, J.

    2012-11-01

    Three in-house X-ray detectors based on diamond chemical vapor deposition (CVD) from the same manufactured batch of single crystal films were investigated for their reproducibility. Leakage current, priming dose, response dynamics, dose linearity, dependence on dose rate and angular dependence were used to evaluate differences between detectors. Slight differences were seen in leakage currents before (<1.5 pA) and after (<12 pA) irradiation. A priming dose of ˜7 Gy and rise and fall times of 2 s were found for all three detectors. Sensitivities differed by up to 10%. Dependence on dose rate were similar (∆=0.92-0.94). Angular dependence was minimal (97-102% avg.). Differences in detector performance appeared to be primarily due to film thickness, which can significantly change sensitivities (nC Gy-1) and applied fields (V μm-1) for detectors with small sensitive volumes. Results suggest that preselection of CVD diamond films according to thickness in addition to material quality would be required to avoid individual calibration, which is performed for commercially available natural diamond detectors.

  16. Organ doses from radionuclides on the ground. Part I. Simple time dependences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacob, P.; Paretzke, H.G.; Rosenbaum, H.

    1988-06-01

    Organ dose equivalents of mathematical, anthropomorphical phantoms ADAM and EVA for photon exposures from plane sources on the ground have been calculated by Monte Carlo photon transport codes and tabulated in this article. The calculation takes into account the air-ground interface and a typical surface roughness, the energy and angular dependence of the photon fluence impinging on the phantom and the time dependence of the contributions from daughter nuclides. Results are up to 35% higher than data reported in the literature for important radionuclides. This manuscript deals with radionuclides, for which the time dependence of dose equivalent rates and dosemore » equivalents may be approximated by a simple exponential. A companion manuscript treats radionuclides with non-trivial time dependences.« less

  17. The Effect of Intra-articular Corticosteroids on Articular Cartilage

    PubMed Central

    Wernecke, Chloe; Braun, Hillary J.; Dragoo, Jason L.

    2015-01-01

    Background: Intra-articular (IA) corticosteroid therapy has been used for the treatment of inflammation and pain in the knee since the 1950s. Purpose: To review the current literature on the effects of IA corticosteroids on articular cartilage. Study Design: Systematic review. Methods: A MEDLINE and SCOPUS database search was performed, and studies were selected for basic science and clinical trial research on corticosteroids with direct outcome measures of cartilage health. Preliminary searches yielded 1929 articles, and final analysis includes 40 studies. Results: Methylprednisolone, dexamethasone, hydrocortisone, betamethasone, prednisolone, and triamcinolone were reported to display dose-dependent deleterious effects on cartilage morphology, histology, and viability in both in vitro and in vivo models. The beneficial animal in vivo effects of methylprednisolone, hydrocortisone, and triamcinolone occurred at low doses (usually <2-3 mg/dose or 8-12 mg/cumulative total dose in vivo), at which increased cell growth and recovery from damage was observed; the single human clinical trial indicated a beneficial effect of triamcinolone. However, at higher doses (>3 mg/dose or 18-24 mg/cumulative total dose in vivo), corticosteroids were associated with significant gross cartilage damage and chondrocyte toxicity. Dose and time dependency of corticosteroid chondrotoxicity was supported in the in vitro results, however, without clear dose thresholds. Conclusion: Corticosteroids have a time- and dose-dependent effect on articular cartilage, with beneficial effects occurring at low doses and durations and detrimental effects at high doses and durations. Clinically, beneficial effects are supported for IA administration, but the lowest efficacious dose should be used. PMID:26674652

  18. Better retention of Malaysian opiate dependents treated with high dose methadone in methadone maintenance therapy

    PubMed Central

    2010-01-01

    Background Methadone is a synthetic opiate mu receptor agonist that is widely used to substitute for illicit opiates in the management of opiate dependence. It helps prevent opiate users from injecting and sharing needles which are vehicles for the spread of HIV and other blood borne viruses. This study has the objective of determining the utility of daily methadone dose to predict retention rates and re-injecting behaviour among opiate dependents. Methods Subjects comprised opiate dependent individuals who met study criteria. They took methadone based on the Malaysian guidelines and were monitored according to the study protocols. At six months, data was collected for analyses. The sensitivity and specificity daily methadone doses to predict retention rates and re-injecting behaviour were evaluated. Results Sixty-four patients volunteered to participate but only 35 (54.69%) remained active and 29 (45.31%) were inactive at 6 months of treatment. Higher doses were significantly correlated with retention rate (p < 0.0001) and re-injecting behaviour (p < 0.001). Of those retained, 80.0% were on 80 mg or more methadone per day doses with 20.0% on receiving 40 mg -79 mg. Conclusions We concluded that a daily dose of at least 40 mg was required to retain patients in treatment and to prevent re-injecting behaviour. A dose of at least 80 mg per day was associated with best results. PMID:21167035

  19. Sex- and dose-dependency in the pharmacokinetics and pharmacodynamics of (+)-methamphetamine and its metabolite (+)-amphetamine in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milesi-Halle, Alessandra; Hendrickson, Howard P.; Laurenzana, Elizabeth M.

    These studies investigated how (+)-methamphetamine (METH) dose and rat sex affect the pharmacological response to METH in Sprague-Dawley rats. The first set of experiments determined the pharmacokinetics of METH and its pharmacologically active metabolite (+)-amphetamine (AMP) in male and female Sprague-Dawley rats after 1.0 and 3.0 mg/kg METH doses. The results showed significant sex-dependent changes in METH pharmacokinetics, and females formed significantly lower amounts of AMP. While the area under the serum concentration-time curve in males increased proportionately with the METH dose, the females showed a disproportional increase. The sex differences in systemic clearance, renal clearance, volume of distribution, andmore » percentage of unchanged METH eliminated in the urine suggested dose-dependent pharmacokinetics in female rats. The second set of studies sought to determine the behavioral implications of these pharmacokinetic differences by quantifying locomotor activity in male and female rats after saline, 1.0, and 3.0 mg/kg METH. The results showed sex- and dose-dependent differences in METH-induced locomotion, including profound differences in the temporal profile of effects at higher dose. These findings show that the pharmacokinetic and metabolic profile of METH (slower METH clearance and lower AMP metabolite formation) plays a significant role in the differential pharmacological response to METH in male and female rats.« less

  20. Sibutramine-induced anorexia: potent, dose-dependent and behaviourally-selective profile in male rats.

    PubMed

    Tallett, A J; Blundell, J E; Rodgers, R J

    2009-03-17

    The serotonin and noradrenaline reuptake inhibitor sibutramine has been licensed as an anti-obesity treatment for more than a decade. However, while inhibitory effects on food intake and weight gain are well documented, surprisingly little published detail exists regarding its influence on feeding and related behaviours. The present study was therefore designed to assess the effects of acute sibutramine treatment on food intake, the behavioural satiety sequence (BSS) and post-treatment weight gain. Subjects were 10 non-deprived adult male Lister hooded rats, tested with 0.5-3.0 mg/kg sibutramine hydrochloride during 1-h DVD-recorded test sessions with palatable mash. Our results show that sibutramine dose-dependently reduced food intake, an effect significant at all doses tested. Ethological analysis revealed very few behavioural effects, except for a dose-dependent reduction in time spent feeding and an increase in the frequency of resting. Behavioural specificity was further supported by time-bin analysis which confirmed both the structural integrity and dose-dependent acceleration of the BSS. Single dosing with sibutramine (3.0 mg/kg) also suppressed daily weight gain over the 24-72 h period post-dosing. Current data support the conclusion that the acute anorectic and weight loss efficacy of sibutramine in adult male rats is not secondary to behavioural disruption but, instead, is due largely to an acceleration in behavioural satiety.

  1. Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac

    NASA Astrophysics Data System (ADS)

    de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-01-01

    To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (<0.1%), dose linearity (⩽0.5%), field size dependency (<2.0% for field sizes larger than 5  ×  5 cm2), dose rate dependency (<1.0%) or angular dependency for any phantom/linac combination. The dose-per-pulse dependency (<0.8%) was found to be significantly different between the two devices. This difference can be explained by the fact that the diodes in the clinical Delta4-PT were irradiated with a much larger dose than the MR-Delta4-PT ones. The absolute difference between the devices (<0.5%) was found to be small, so no clinical impact is expected. For both devices, the results were consistent with the characteristics of the Delta4-PT device reported in the literature (Bedford et al 2009 Phys. Med. Biol. 54 N167-76 Sadagopan et al 2009 J. Appl. Clin. Med. Phys. 10 2928). We found that the characteristics of the MR compatible Delta4 phantom were found to be comparable to the clinically used one. Also, the found characteristics do not differ from the previously reported characteristics of the commercially available non-MR compatible Delta4-PT phantom. Therefore, the MR compatible Delta4 prototype was found to be safe and effective for use in the 1.5 tesla magnetic field of the Elekta MR-linac

  2. An atlas-based organ dose estimator for tomosynthesis and radiography

    NASA Astrophysics Data System (ADS)

    Hoye, Jocelyn; Zhang, Yakun; Agasthya, Greeshma; Sturgeon, Greg; Kapadia, Anuj; Segars, W. Paul; Samei, Ehsan

    2017-03-01

    The purpose of this study was to provide patient-specific organ dose estimation based on an atlas of human models for twenty tomosynthesis and radiography protocols. The study utilized a library of 54 adult computational phantoms (age: 18-78 years, weight 52-117 kg) and a validated Monte-Carlo simulation (PENELOPE) of a tomosynthesis and radiography system to estimate organ dose. Positioning of patient anatomy was based on radiographic positioning handbooks. The field of view for each exam was calculated to include relevant organs per protocol. Through simulations, the energy deposited in each organ was binned to estimate normalized organ doses into a reference database. The database can be used as the basis to devise a dose calculator to predict patient-specific organ dose values based on kVp, mAs, exposure in air, and patient habitus for a given protocol. As an example of the utility of this tool, dose to an organ was studied as a function of average patient thickness in the field of view for a given exam and as a function of Body Mass Index (BMI). For tomosynthesis, organ doses can also be studied as a function of x-ray tube position. This work developed comprehensive information for organ dose dependencies across tomosynthesis and radiography. There was a general exponential decrease dependency with increasing patient size that is highly protocol dependent. There was a wide range of variability in organ dose across the patient population, which needs to be incorporated in the metrology of organ dose.

  3. Sci—Fri PM: Topics — 06: The influence of regional dose sensitivity on salivary loss and recovery in the parotid gland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, H; BC Cancer Agency, Surrey, B.C.; BC Cancer Agency, Vancouver, B.C.

    Purpose: The Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC 2010) survey of radiation dose-volume effects on salivary gland function has called for improved understanding of intragland dose sensitivity and the effectiveness of partial sparing in salivary glands. Regional dose susceptibility of sagittally- and coronally-sub-segmented parotid gland has been studied. Specifically, we examine whether individual consideration of sub-segments leads to improved prediction of xerostomia compared with whole parotid mean dose. Methods: Data from 102 patients treated for head-and-neck cancers at the BC Cancer Agency were used in this study. Whole mouth stimulated saliva was collected before (baseline), threemore » months, and one year after cessation of radiotherapy. Organ volumes were contoured using treatment planning CT images and sub-segmented into regional portions. Both non-parametric (local regression) and parametric (mean dose exponential fitting) methods were employed. A bootstrap technique was used for reliability estimation and cross-comparison. Results: Salivary loss is described well using non-parametric and mean dose models. Parametric fits suggest a significant distinction in dose response between medial-lateral and anterior-posterior aspects of the parotid (p<0.01). Least-squares and least-median squares estimates differ significantly (p<0.00001), indicating fits may be skewed by noise or outliers. Salivary recovery exhibits a weakly arched dose response: the highest recovery is seen at intermediate doses. Conclusions: Salivary function loss is strongly dose dependent. In contrast no useful dose dependence was observed for function recovery. Regional dose dependence was observed, but may have resulted from a bias in dose distributions.« less

  4. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    PubMed

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  5. Distinct DC subsets regulate adaptive Th1 and 2 responses during Trichuris muris infection.

    PubMed

    Demiri, M; Müller-Luda, K; Agace, W W; Svensson-Frej, M

    2017-10-01

    Low- and high-dose infections with the murine large intestinal nematode Trichuris muris are associated with induction of adaptive Th1 and Th2 responses, respectively, in mesenteric lymph nodes (MLN). Classical dendritic cells (cDC) accumulate in the large intestinal mucosa and MLN upon T. muris infection, yet their role in driving adaptive responses to infection remains largely unknown. We performed low- and high-dose T. muris infections of mice deficient in defined cDC subsets to investigate their role in induction of adaptive immune responses. Mice lacking IRF4-dependent cDC failed to clear a high-dose infection and displayed impaired Th2 responses. Conversely, mice lacking IRF8-dependent cDC cleared a low-dose infection and displayed an impaired Th1 response while increased production of Th2 cytokines. Finally, mice lacking both IRF4- and IRF8-dependent cDC were able to generate a Th2 response and clear a low-dose infection. Collectively, these results suggest that IRF4- and IRF8-dependent cDC act antagonistically during T. muris infection, and demonstrate that intestinal Th2 responses can be generated towards T. muris in the absence of IRF4-dependent cDC. © 2017 John Wiley & Sons Ltd.

  6. Open-label dose-finding trial of buprenorphine implants (Probuphine) for treatment of heroin dependence.

    PubMed

    White, Jason; Bell, James; Saunders, John B; Williamson, Paul; Makowska, Maria; Farquharson, Aaron; Beebe, Katherine L

    2009-07-01

    Buprenorphine, a mu-opioid receptor partial agonist, has been shown to be safe and effective for treatment of opioid dependence. A novel implantable formulation of buprenorphine (Probuphine), using a polymer matrix sustained-release technology, has been developed to offer treatment for opioid dependence while minimizing risks of patient noncompliance and illicit diversion. The goal of the current study was to conduct an initial, open-label, evaluation of the safety, pharmacokinetics, and efficacy of two doses of Probuphine in subjects with opioid dependence maintained on sublingual buprenorphine. Two doses of Probuphine were evaluated in 12 heroin-dependent volunteers switched from daily sublingual buprenorphine dosing to either two or four Probuphine implants based upon their buprenorphine daily maintenance dose of 8 mg or 16 mg respectively, and were monitored for 6 months. Probuphine implants provided continuous steady state delivery of buprenorphine until their removal at 6 months. Withdrawal symptoms and craving remained low throughout the 6 months. For the 12 subjects, an average of 59% of urines were opioid-negative across the 6 month treatment period. Injection site reactions were present in half of patients, but none were serious. No safety concerns were evident. These results suggest that Probuphine implants offer significant promise for enhancing delivery of effective opioid substitution treatment while minimizing risk for abuse of medication.

  7. Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques

    PubMed Central

    Deshpande, Sudesh; Dhote, Deepak; Thakur, Kalpna; Pawar, Amol; Kumar, Rajesh; Kumar, Munish; Kulkarni, M. S.; Sharma, S. D.; Kannan, V.

    2016-01-01

    The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient geometry and distance of isocenter to the eye lens. During the experimental measurements, OSLD was placed on the patient between the eyebrows of both eyes in line of nose during CBCT image acquisition to measure eye lens doses. The eye lens dose measurements were carried out for three different cone-beam acquisition protocols (standard dose head, low-dose head [LDH], and high-quality head [HQH]) of Varian OBI. Measured doses were correlated with patient geometry and distance between isocenter and eye lens. Measured eye lens doses for standard head and HQH protocols were in the range of 1.8–3.2 mGy and 4.5–9.9 mGy, respectively. However, the measured eye lens dose for the LDH protocol was in the range of 0.3–0.7 mGy. The measured data indicate that eye lens dose to patient depends on the selected imaging protocol. It was also observed that eye lens dose does not depend on patient geometry but strongly depends on distance between eye lens and treatment field isocenter. However, undoubted advantages of imaging system should not be counterbalanced by inappropriate selection of imaging protocol, especially for very intense imaging protocol. PMID:27651564

  8. Characterization of the role of Fhit in maintenance of genomic integrity following low dose radiation, in vivo and in vitro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ya Wang

    2010-05-31

    The major goal of this study is to determine the effects of the Fhit pathway on low dose ({le} 0.1 Gy) ionizing radiation (IR)-induced genetic instability. Reduction of Fhit protein expression is observed in most solid tumors particularly in those tumors resulting from exposure to environmental carcinogens. Therefore, characterization of the role of the Fhit-dependent pathway in preventing low dose IR-induced genetic instability will provide useful parameters for evaluating the low dose IR-induced risk of mutagenesis and carcinogenesis. We pursued 3 specific aims to study our hypothesis that the Fhit-dependent pathways maintain genomic integrity through adjusting checkpoint response and repairmore » genes expression following low dose IR. Aim 1: Determine whether Fhit interaction with RPA is necessary for Fhit to affect the cellular response to low dose IR. We combined the approaches of in vitro (GST pull-down and site-directed mutagenesis) and in vivo (observing the co-localization and immunoprecipitation of Fhit and RPA in Fhit knock out mouse cells transfected with mutant Fhit which has lost ability to interact with RPA in vitro). Aim 2: Determine the role of genes whose expression is affected by Fhit in low dose irradiated cells. We analyzed the distinct signature of gene expression in low dose irradiated Fhit-/- cells compared with Fhit+/+ cells by combining microarray, gene transfection and siRNA approaches. Aim 3: Determine the role of Fhit in genetic susceptibility to low dose IR in vivo. We compared the gene mutation frequency and the fragile site stability in the cells isolated from the Fhit+/+ and Fhit-/- mice at 1.5 years following low dose IR. These results determine the role of the Fhit-dependent pathway in maintaining genomic integrity in vitro and in vivo, which provide a basis for choosing surrogate markers in the Fhit-dependent pathway to evaluate low dose IR-induced risk of mutagenesis and carcinogenesis.« less

  9. SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakalyar, D; McKenney, S; Feng, W

    Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution canmore » be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.« less

  10. Ionizing radiation sensitivity of the ocular lens and its dose rate dependence.

    PubMed

    Hamada, Nobuyuki

    2017-10-01

    In 2011, the International Commission on Radiological Protection reduced the threshold for the lens effects of low linear energy transfer (LET) radiation. On one hand, the revised threshold of 0.5 Gy is much lower than previously recommended thresholds, but mechanisms behind high radiosensitivity remain incompletely understood. On the other hand, such a threshold is independent of dose rate, in contrast to previously recommended separate thresholds each for single and fractionated/protracted exposures. Such a change was made predicated on epidemiological evidence suggesting that a threshold for fractionated/protracted exposures is not higher than an acute threshold, and that a chronic threshold is uncertain. Thus, the dose rate dependence is still unclear. This paper therefore reviews the current knowledge on the radiosensitivity of the lens and the dose rate dependence of radiation cataractogenesis, and discusses its mechanisms. Mounting biological evidence indicates that the lens cells are not necessarily radiosensitive to cell killing, and the high radiosensitivity of the lens thus appears to be attributable to other mechanisms (e.g., excessive proliferation, abnormal differentiation, a slow repair of DNA double-strand breaks, telomere, senescence, crystallin changes, non-targeted effects and inflammation). Both biological and epidemiological evidence generally supports the lack of dose rate effects. However, there is also biological evidence for the tissue sparing dose rate (or fractionation) effect of low-LET radiation and an enhancing inverse dose fractionation effect of high-LET radiation at a limited range of LET. Emerging epidemiological evidence in chronically exposed individuals implies the inverse dose rate effect. Further biological and epidemiological studies are warranted to gain deeper knowledge on the radiosensitivity of the lens and dose rate dependence of radiation cataractogenesis.

  11. SU-G-201-08: Energy Response of Thermoluminescent Microcube Dosimeters in Water for Kilovoltage X-Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Maso, L; Lawless, M; Culberson, W

    Purpose: To characterize the energy dependence for TLD-100 microcubes in water at kilovoltage energies. Methods: TLD-100 microcubes with dimensions of (1 × 1 × 1) mm{sup 3} were irradiated with kilovoltage x-rays in a custom-built thin-window liquid water phantom. The TLD-100 microcubes were held in Virtual Water™ probes and aligned at a 2 cm depth in water. Irradiations were performed using the M-series x-ray beams of energies ranging from 50-250 kVp and normalized to a {sup 60}Co beam located at the UWADCL. Simulations using the EGSnrc Monte Carlo Code System were performed to model the x-ray beams, the {sup 60}Comore » beam, the water phantom and the dosimeters in the phantom. The egs-chamber user code was used to tally the dose to the TLDs and the dose to water. The measurements and calculations were used to determine the intrinsic energy dependence, absorbed-dose energy dependence, and absorbed-dose sensitivity. These values were compared to TLD-100 chips with dimensions of (3.2 × 0.9 × 0.9) mm{sup 3}. Results: The measured TLD-100 microcube response per dose to water among all investigated x-ray energies had a maximum percent difference of 61% relative to {sup 60}Co. The simulated ratio of dose to water to the dose to TLD had a maximum percent difference of 29% relative to {sup 60}Co. The ratio of dose to TLD to the TLD output had a maximum percent difference of 13% relative to {sup 60}Co. The maximum percent difference for the absorbed-dose sensitivity was 15% more than the used value of 1.41. Conclusion: These results confirm that differences in beam quality have a significant effect on TLD response when irradiated in water. These results also indicated a difference in TLD-100 response between microcube and chip geometries. The intrinsic energy dependence and the absorbed-dose energy dependence deviated up to 10% between TLD-100 microcubes and chips.« less

  12. On the Star Formation-AGN Connection at zeta (is) approximately greater than 0.3

    NASA Technical Reports Server (NTRS)

    LaMassa, Stephanie M.; Heckman, T. M.; Ptak, Andrew; Urry, C. Megan

    2013-01-01

    Using the spectra of a sample of approximately 28,000 nearby obscured active galaxies from Data Release 7 of the Sloan Digital Sky Survey (SDSS), we probe the connection between active galactic nucleus (AGN) activity and star formation over a range of radial scales in the host galaxy. We use the extinction-corrected luminosity of the [O iii] 5007A line as a proxy of intrinsic AGN power and supermassive black hole (SMBH) accretion rate. The star formation rates (SFRs) are taken from the MPA-JHU value-added catalog and are measured through the 3 inch SDSS aperture. We construct matched samples of galaxies covering a range in redshifts. With increasing redshift, the projected aperture size encompasses increasing amounts of the host galaxy. This allows us to trace the radial distribution of star formation as a function of AGN luminosity. We find that the star formation becomes more centrally concentrated with increasing AGN luminosity and Eddington ratio. This implies that such circumnuclear star formation is associated with AGN activity, and that it increasingly dominates over omnipresent disk star formation at higher AGN luminosities, placing critical constraints on theoretical models that link host galaxy star formation and SMBH fueling. We parameterize this relationship and find that the star formation on radial scales (is) less than 1.7 kpc, when including a constant disk component, has a sub-linear dependence on SMBH accretion rate: SFR in proportion to solar mass(sup 0.36), suggesting that angular momentum transfer through the disk limits accretion efficiency rather than the supply from stellar mass loss.

  13. Dose-dependent fate of GFP-E. coli in the alimentary canal of adult house flies

    PubMed Central

    Naveen, Kumar H.V.; Nayduch, Dana

    2015-01-01

    Adult house flies (Diptera: Muscidae; Musca domestica L.) can disseminate bacteria from microbe-rich substrates to areas where humans and domesticated animals reside. Because bacterial abundance fluctuates widely across substrates, flies encounter and ingest varying amounts of bacteria. We investigated the dose-dependent survival of bacteria in house flies. Flies were fed four different “doses” of GFP-expressing Escherichia coli (GFP E. coli; very low, low, medium, high, defined in text) and survival was determined at 1, 4, 10 and 22 h post-ingestion via culture and epiflourescent microscopy. Over 22 h, decline of GFP E. coli was significant for all treatments (P<0.04) except the very low dose (P=0.235). Change in survival (Δ S) did not differ between flies fed low and very low doses of bacteria across all time points, although both treatments differed from flies fed high and medium bacterial doses at several time points. At 4, 10 and 22 h, GFP E. coli Δ S significantly differed between medium and high dose-fed flies. A threshold dose, above which bacteria are detected and destroyed by house flies, may exist and likely is immune-mediated. Understanding dose-dependent bacterial survival in flies can help in predicting bacteria transmission potential. PMID:26843509

  14. Acute ethanol ingestion produces dose-dependent effects on motor behavior in the honey bee (Apis mellifera)

    PubMed Central

    Maze, Ian S.; Wright, Geraldine A.; Mustard, Julie A.

    2006-01-01

    Ethanol consumption produces characteristic behavioral states in animals that include sedation, disorientation, and disruption of motor function. Using individual honey bees, we assessed the effects of ethanol ingestion on motor function via continuous observations of their behavior. Consumption of 1 M sucrose solutions containing a range of ethanol doses lead to hemolymph ethanol levels of approximately 40 to 100 mM. Using ethanol doses in this range, we observed time and dose-dependent effects of ethanol on the percent of time our subjects spent walking, stopped, or upside down, and on the duration and frequency of bouts of behavior. The effects on grooming and flying behavior were more complex. Behavioral recovery from ethanol treatment was both time and ethanol dose dependent, occurring between 12 and 24 hr post-ingestion for low doses and at 24 to 48 hours for higher doses. Furthermore, the amount of ethanol measured in honey bee hemolymph appeared to correlate with recovery. We predict that the honey bee will prove to be an excellent model system for studying the influence of ethanol on the neural mechanisms underlying behavior. PMID:17070538

  15. Effects of Alcohol on Performance on a Distraction Task During Simulated Driving

    PubMed Central

    Allen, Allyssa J.; Meda, Shashwath A.; Skudlarski, Pawel; Calhoun, Vince; Astur, Robert; Ruopp, Kathryn C.; Pearlson, Godfrey D.

    2009-01-01

    Background Prior studies report that accidents involving intoxicated drivers are more likely to occur during performance of secondary tasks. We studied this phenomenon, using a dual-task paradigm, involving performance of a visual oddball (VO) task while driving in an alcohol challenge paradigm. Previous functional MRI (fMRI) studies of the VO task have shown activation in the anterior cingulate, hippocampus, and prefrontal cortex. Thus, we predicted dose-dependent decreases in activation of these areas during VO performance. Methods Forty healthy social drinkers were administered 3 different doses of alcohol, individually tailored to their gender and weight. Participants performed a VO task while operating a virtual reality driving simulator in a 3T fMRI scanner. Results Analysis showed a dose-dependent linear decrease in Blood Oxygen Level Dependent activation during task performance, primarily in hippocampus, anterior cingulate, and dorsolateral prefrontal areas, with the least activation occurring during the high dose. Behavioral analysis showed a dose-dependent linear increase in reaction time, with no effects associated with either correct hits or false alarms. In all dose conditions, driving speed decreased significantly after a VO stimulus. However, at the high dose this decrease was significantly less. Passenger-side line crossings significantly increased at the high dose. Conclusions These results suggest that driving impairment during secondary task performance may be associated with alcohol-related effects on the above brain regions, which are involved with attentional processing/decision-making. Drivers with high blood alcohol concentrations may be less able to orient or detect novel or sudden stimuli during driving. PMID:19183133

  16. Characterization of MOSFET dosimeters for low‐dose measurements in maxillofacial anthropomorphic phantoms

    PubMed Central

    Wolff, Jan E.; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-01-01

    The aims of this study were to characterize reinforced metal‐oxide‐semiconductor field‐effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low‐dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50–90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point‐dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k=2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low‐dose limit. The sensitivity was 3.09±0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was −8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD‐comparable low‐dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low. PACS number: 87.50.wj PMID:26219008

  17. Dose-dependent catch-up growth after 2 years of growth hormone treatment in intrauterine growth-retarded children. Belgian and French Pediatric Clinics and Sanofi-Choay (France).

    PubMed

    Chatelain, P; Job, J C; Blanchard, J; Ducret, J P; Oliver, M; Sagnard, L; Vanderschueren-Lodeweyckx, M

    1994-06-01

    This study reports the results of a 2-yr clinical trial with GH in 95 short prepubertal children with non-GH-deficient intrauterine growth retardation. This randomized, double blind, controlled study compared the effects of placebo (restricted to the first 6 months) and two doses of GH (0.4 and 1.2 IU/kg.week) given sc 6 days/week for 2 yr. A significant GH dose-dependent growth acceleration was observed. Mean height gain (SDS/CA) was 0.66 +/- 0.07 in group I (low dose, 0.4 IU/kg.week) compared to 1.25 +/- 0.07 in group II (high dose, 1.2 IU/kg.week). Mean bone maturation progression (expressed in months) was 26.2 +/- 1.7 and 30.2 +/- 1.5 over 24 months in groups I and II, respectively. Onset of puberty was observed in some patients of both groups. Whether chronic use of a high GH dose will advance the onset of puberty remains to be established. A great variability of growth acceleration was seen among GH dose groups, suggesting that factors in addition to GH dose might modulate individual responses to treatment. In conclusion, it is suggested that in these patients, dose-dependent catch-up growth could be induced by GH treatment.

  18. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.

    PubMed

    Karsch, L; Beyreuther, E; Burris-Mog, T; Kraft, S; Richter, C; Zeil, K; Pawelke, J

    2012-05-01

    The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10(11) Gy∕s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. The dosimeters are dose rate independent up to 4●10(9) Gy∕s within 2% (OSL and TLD) and up to 15●10(9) Gy∕s within 5% (EBT films). The diamond detectors show strong dose rate dependence. TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  19. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the numbermore » of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.« less

  20. NOTE: Investigating the potential of polymer gel dosimetry for interventional radiology: first results

    NASA Astrophysics Data System (ADS)

    Antoniou, P. E.; Bousbouras, P.; Sandaltzopoulos, R.; Kaldoudi, E.

    2008-04-01

    Complex interventional radiology (IR) procedures contribute an increasing percentage of the overall medical radiation exposure of the population making accurate dosimetry a challenge. Magnetic resonance (MR) based polymer gel dosimetry has been widely employed in complex dosimetric problems in radiotherapy. The aim of this note is to investigate the feasibility of normoxic gel dosimetry in IR. Dose response, energy dependence and dose rate dependence were investigated in irradiation set-ups relevant to IR for a particular normoxic gel, based on methacrylic acid (MAA) as the monomer and including tetrakis-hydroxy-methyl-phosphonium chloride (THPC) as antioxidant. The gel presents a linear dose response beyond a 25 cGy threshold. No significant energy dependence was observed in the useful range of interventional radiology (80-110 kVp). A linear correlation between the gel response and dose rate was observed in the range of dose rates relevant to IR (5-8 cGy min-1). These results demonstrate a reduction of gel sensitivity at very low dose rate levels. A possible explanation of this effect is suggested.

  1. The affect of low-coherent light on microbial colony forming ability and morphology of some gram-positive and gram-negative bacteria

    NASA Astrophysics Data System (ADS)

    Popov, Denis E.; Tuchina, Elena S.; Chernova, Julia A.; Podshibyakin, Dmitry; Rudik, Dmitry V.; Samsonova, Maria; Gromov, Igor; Tuchin, Valery V.

    2005-06-01

    Gram-negative E. coli, gram-positive facultative anaerobe cocci Staphylococcus lugdensis, Micrococcus halobius, and Stomatococcus mucilaginosus as subjects of study were chosen. LEDs with spectrum maxima at 405 nm (without any exogenous sensitizer) and 660 nm (in conjunction with methylene blue) and power densities of 23 mW/cm2 and 5.7 mW/cm2 accordingly as continuous light sources were chosen. Photosensitized light's affect by methylene blue was studied on E. coli only. The original scheme of experiment set up was developed. It permits one to increase expositions quantity in each experiment for more certain trend's construction over dose curves and decrease parasite flora sowing. As a result of accomplished studies it was established that blue low-coherent light have unalike weak light's dose depending suppressing effect on cocci whereas red low-coherent light have a moderate dose-depended suppressing effect at low irradiation doses and a moderate dose-depended stimulating effect at high irradiation doses on sensitized by MeBlue E. coli. For all ofthis, but Staphylococcus morphology changes were observed.

  2. Dose-Dependent Effects of Theta Burst rTMS on Cortical Excitability and Resting-State Connectivity of the Human Motor System

    PubMed Central

    Nettekoven, Charlotte; Volz, Lukas J.; Kutscha, Martha; Pool, Eva-Maria; Rehme, Anne K.; Eickhoff, Simon B.; Fink, Gereon R.

    2014-01-01

    Theta burst stimulation (TBS), a specific protocol of repetitive transcranial magnetic stimulation (rTMS), induces changes in cortical excitability that last beyond stimulation. TBS-induced aftereffects, however, vary between subjects, and the mechanisms underlying these aftereffects to date remain poorly understood. Therefore, the purpose of this study was to investigate whether increasing the number of pulses of intermittent TBS (iTBS) (1) increases cortical excitability as measured by motor-evoked potentials (MEPs) and (2) alters functional connectivity measured using resting-state fMRI, in a dose-dependent manner. Sixteen healthy, human subjects received three serially applied iTBS blocks of 600 pulses over the primary motor cortex (M1 stimulation) and the parieto-occipital vertex (sham stimulation) to test for dose-dependent iTBS effects on cortical excitability and functional connectivity (four sessions in total). iTBS over M1 increased MEP amplitudes compared with sham stimulation after each stimulation block. Although the increase in MEP amplitudes did not differ between the first and second block of M1 stimulation, we observed a significant increase after three blocks (1800 pulses). Furthermore, iTBS enhanced resting-state functional connectivity between the stimulated M1 and premotor regions in both hemispheres. Functional connectivity between M1 and ipsilateral dorsal premotor cortex further increased dose-dependently after 1800 pulses of iTBS over M1. However, no correlation between changes in MEP amplitudes and functional connectivity was detected. In summary, our data show that increasing the number of iTBS stimulation blocks results in dose-dependent effects at the local level (cortical excitability) as well as at a systems level (functional connectivity) with a dose-dependent enhancement of dorsal premotor cortex-M1 connectivity. PMID:24828639

  3. Effects of aqueous, methanolic and chloroform extracts of rhizome and aerial parts of Valeriana officinalis L. on naloxone-induced jumping in morphine-dependent mice.

    PubMed

    Sharifzadeh, Mohammad; Hadjiakhoondi, Abbas; Khanavi, Mahnaz; Susanabadi, Maryam

    2006-06-01

    In the present study, the effects of rhizomes and aerial parts extracts of Valeriana officinalis L. on morphine dependence in mice have been investigated. Animals were treated subcutaneously with morphine (50, 50 and 75 mg/kg) three times daily (10 am, 1 pm and 4 pm) for 3 days, and a last dose of morphine (50 mg/kg) was administered on the fourth day. Withdrawal syndrome (jumping) was precipitated by naloxone (5 mg/kg) which was administered intraperitoneally 2 hours after the last dose of morphine. To study the effects of the aqueous, methanolic and chloroform extracts of both aerial parts and rhizome of the V. officinalis L. on naloxone-induced jumping in morphine-dependent animals, 10 injections of morphine (three administrations each day) for dependence and a dose of 5 mg/kg of naloxone for withdrawal induction were employed. Intraperitoneal injection of different doses (1, 5, 25 and 50 mg/kg) of aqueous, methanolic and chloroform extracts of the rhizome of V. officinalis L. 60 minutes before naloxone injection decreased the jumping response dose-dependently. Pre-treatment of animals with different doses (1, 5, 25, 50 and 100 mg/kg) of aqueous and methanolic extracts of aerial parts of V. officinalis L. 60 minutes before naloxone injection caused a significant decrease on naloxone-induced jumping. The chloroform extract of the aerial parts of V. officinalis L. did not show any significant changes on jumping response in morphine-dependent animals. It is concluded that the extracts of V. officinalis L. could affect morphine withdrawal syndrome via possible interactions with inhibitory neurotransmitters in nervous system.

  4. Time dependent pre-treatment EPID dosimetry for standard and FFF VMAT.

    PubMed

    Podesta, Mark; Nijsten, Sebastiaan M J J G; Persoon, Lucas C G G; Scheib, Stefan G; Baltes, Christof; Verhaegen, Frank

    2014-08-21

    Methods to calibrate Megavoltage electronic portal imaging devices (EPIDs) for dosimetry have been previously documented for dynamic treatments such as intensity modulated radiotherapy (IMRT) using flattened beams and typically using integrated fields. While these methods verify the accumulated field shape and dose, the dose rate and differential fields remain unverified. The aim of this work is to provide an accurate calibration model for time dependent pre-treatment dose verification using amorphous silicon (a-Si) EPIDs in volumetric modulated arc therapy (VMAT) for both flattened and flattening filter free (FFF) beams. A general calibration model was created using a Varian TrueBeam accelerator, equipped with an aS1000 EPID, for each photon spectrum 6 MV, 10 MV, 6 MV-FFF, 10 MV-FFF. As planned VMAT treatments use control points (CPs) for optimization, measured images are separated into corresponding time intervals for direct comparison with predictions. The accuracy of the calibration model was determined for a range of treatment conditions. Measured and predicted CP dose images were compared using a time dependent gamma evaluation using criteria (3%, 3 mm, 0.5 sec). Time dependent pre-treatment dose verification is possible without an additional measurement device or phantom, using the on-board EPID. Sufficient data is present in trajectory log files and EPID frame headers to reliably synchronize and resample portal images. For the VMAT plans tested, significantly more deviation is observed when analysed in a time dependent manner for FFF and non-FFF plans than when analysed using only the integrated field. We show EPID-based pre-treatment dose verification can be performed on a CP basis for VMAT plans. This model can measure pre-treatment doses for both flattened and unflattened beams in a time dependent manner which highlights deviations that are missed in integrated field verifications.

  5. Dose- and time-dependent pharmacokinetics of apigenin trimethyl ether.

    PubMed

    Elhennawy, Mai Gamal; Lin, Hai-Shu

    2018-06-15

    Apigenin trimethyl ether (5,7,4'-trimethoxyflavone, ATE), one of the key polymethoxyflavones present in black ginger (rhizome of Kaempferia parviflora) possesses various health-promoting activities. To optimize its medicinal application, the pharmacokinetics of ATE was assessed in Sprague-Dawley rats with emphases to identify the impacts from dose and repeated dosing on its major pharmacokinetic parameters. Plasma ATE levels were monitored by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Upon single intravenous administration (2 mg/kg), plasma levels of ATE declined through an apparent first-order process while dose-escalation to 4 and 8 mg/kg led to its non-linear disposition, which could be described by the Michaelis-Menten model. Similarly, dose-dependent oral pharmacokinetics was confirmed and when the dose was escalated from 5 to 15 and 45 mg/kg, much longer mean residence time (MRT 0→last ), higher dose-normalized maximal plasma concentration (C max /Dose) and exposure (AUC/Dose) were observed at 15 and/or 45 mg/kg. One-week daily oral administration of ATE at 15 mg/kg caused its accelerated elimination and the plasma exposure (AUC) after intravenous (2 mg/kg) and oral administration (15 mg/kg) dropped ~40 and 60%, respectively. As ATE displayed both dose- and time-dependent pharmacokinetics, caution is needed in the medicinal applications of ATE and/or black ginger. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses to the soft tissues for females are larger by 20% than the doses for males, because of the differences in the whole-body mass between males and females.

  7. SEMICONDUCTOR PHYSICS Dose-rate dependence of optically stimulated luminescence signal

    NASA Astrophysics Data System (ADS)

    Pingqiang, Wei; Zhaoyang, Chen; Yanwei, Fan; Yurun, Sun; Yun, Zhao

    2010-10-01

    Optically stimulated luminescence (OSL) is the luminescence emitted from a semiconductor during its exposure to light. The OSL intensity is a function of the total dose absorbed by the sample. The dose-rate dependence of the OSL signal of the semiconductor CaS doped Ce and Sm was studied by numerical simulation and experiments. Based on a one-trap/one-center model, the whole OSL process was represented by a series of differential equations. The dose-rate properties of the materials were acquired theoretically by solving the equations. Good coherence was achieved between numerical simulation and experiments, both of which showed that the OSL signal was independent of dose rate. This result validates that when using OSL as a dosimetry technique, the dose-rate effect can be neglected.

  8. Dose-dependent biodistribution of prenatal exposure to rutile-type titanium dioxide nanoparticles on mouse testis

    NASA Astrophysics Data System (ADS)

    Kubo-Irie, Miyoko; Uchida, Hiroki; Mastuzawa, Shotaro; Yoshida, Yasuko; Shinkai, Yusuke; Suzuki, Kenichiro; Yokota, Satoshi; Oshio, Shigeru; Takeda, Ken

    2014-02-01

    Titanium dioxide nanoparticles (nano-TiO2), believed to be inert and safe, are used in many products especially rutile-type in cosmetics. Detection, localization, and count of nanoparticles in tissue sections are of considerable current interest. Here, we evaluate the dose-dependent biodistribution of rutile-type nano-TiO2 exposure during pregnancy on offspring testes. Pregnant mice were subcutaneously injected five times with 0.1 ml of sequentially diluted of nano-TiO2 powder, 35 nm with primary diameter, suspensions (1, 10, 100, or 1,000 μg/ml), and received total doses of 0.5, 5, 50, and 500 μg, respectively. Prior to injection, the size distribution of nano-TiO2 was analyzed by dynamic light scattering measurement. The average diameter was increased in a dose-dependent manner. The most diluted concentration, 1 μg/ml suspension, contained small agglomerates averaging 193.3 ± 5.4 nm in diameter. The offspring testes were examined at 12 weeks postpartum. Individual particle analysis in testicular sections under scanning and transmission electron microscopy enabled us to understand the biodistribution. The correlation between nano-TiO2 doses injected to pregnant mice, and the number of agglomerates in the offspring testes was demonstrated to be dose-dependent by semiquantitative evaluation. However, the agglomerate size was below 200 nm in the testicular sections of all recipient groups, independent from the injected dose during pregnancy.

  9. The energy dependence of the lateral dose response functions of detectors with various densities in photon-beam dosimetry.

    PubMed

    Looe, Hui Khee; Harder, Dietrich; Poppe, Björn

    2017-02-07

    The lateral dose response function is a general characteristic of the volume effect of a detector used for photon dosimetry in a water phantom. It serves as the convolution kernel transforming the true absorbed dose to water profile, which would be produced within the undisturbed water phantom, into the detector-measured signal profile. The shape of the lateral dose response function characterizes (i) the volume averaging attributable to the detector's size and (ii) the disturbance of the secondary electron field associated with the deviation of the electron density of the detector material from the surrounding water. In previous work, the characteristic dependence of the shape of the lateral dose response function upon the electron density of the detector material was studied for 6 MV photons by Monte Carlo simulation of a wall-less voxel-sized detector (Looe et al 2015 Phys. Med. Biol. 60 6585-07). This study is here continued for 60 Co gamma rays and 15 MV photons in comparison with 6 MV photons. It is found (1) that throughout these photon spectra the shapes of the lateral dose response functions are retaining their characteristic dependence on the detector's electron density, and (2) that their energy-dependent changes are only moderate. This appears as a practical advantage because the lateral dose response function can then be treated as practically invariant across a clinical photon beam in spite of the known changes of the photon spectrum with increasing distance from the beam axis.

  10. An Advanced Hierarchical Hybrid Environment for Reliability and Performance Modeling

    NASA Technical Reports Server (NTRS)

    Ciardo, Gianfranco

    2003-01-01

    The key issue we intended to address in our proposed research project was the ability to model and study logical and probabilistic aspects of large computer systems. In particular, we wanted to focus mostly on automatic solution algorithms based on a state-space exploration as their first step, in addition to the more traditional discrete-event simulation approaches commonly employed in industry. One explicitly-stated goal was to extend by several orders of magnitude the size of models that can be solved exactly, using a combination of techniques: 1) Efficient exploration and storage of the state space using new data structures that require an amount of memory sublinear in the number states; and 2) Exploitation of the existing symmetries in the matrices describing the system behavior using Kronecker operators. Not only we have been successful in achieving the above goals, but we exceeded them in many respects.

  11. PRIM: An Efficient Preconditioning Iterative Reweighted Least Squares Method for Parallel Brain MRI Reconstruction.

    PubMed

    Xu, Zheng; Wang, Sheng; Li, Yeqing; Zhu, Feiyun; Huang, Junzhou

    2018-02-08

    The most recent history of parallel Magnetic Resonance Imaging (pMRI) has in large part been devoted to finding ways to reduce acquisition time. While joint total variation (JTV) regularized model has been demonstrated as a powerful tool in increasing sampling speed for pMRI, however, the major bottleneck is the inefficiency of the optimization method. While all present state-of-the-art optimizations for the JTV model could only reach a sublinear convergence rate, in this paper, we squeeze the performance by proposing a linear-convergent optimization method for the JTV model. The proposed method is based on the Iterative Reweighted Least Squares algorithm. Due to the complexity of the tangled JTV objective, we design a novel preconditioner to further accelerate the proposed method. Extensive experiments demonstrate the superior performance of the proposed algorithm for pMRI regarding both accuracy and efficiency compared with state-of-the-art methods.

  12. Segmented molecular design of self-healing proteinaceous materials

    PubMed Central

    Sariola, Veikko; Pena-Francesch, Abdon; Jung, Huihun; Çetinkaya, Murat; Pacheco, Carlos; Sitti, Metin; Demirel, Melik C.

    2015-01-01

    Hierarchical assembly of self-healing adhesive proteins creates strong and robust structural and interfacial materials, but understanding of the molecular design and structure–property relationships of structural proteins remains unclear. Elucidating this relationship would allow rational design of next generation genetically engineered self-healing structural proteins. Here we report a general self-healing and -assembly strategy based on a multiphase recombinant protein based material. Segmented structure of the protein shows soft glycine- and tyrosine-rich segments with self-healing capability and hard beta-sheet segments. The soft segments are strongly plasticized by water, lowering the self-healing temperature close to body temperature. The hard segments self-assemble into nanoconfined domains to reinforce the material. The healing strength scales sublinearly with contact time, which associates with diffusion and wetting of autohesion. The finding suggests that recombinant structural proteins from heterologous expression have potential as strong and repairable engineering materials. PMID:26323335

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamblin, T; de Supinski, B R; Schulz, M

    Good load balance is crucial on very large parallel systems, but the most sophisticated algorithms introduce dynamic imbalances through adaptation in domain decomposition or use of adaptive solvers. To observe and diagnose imbalance, developers need system-wide, temporally-ordered measurements from full-scale runs. This potentially requires data collection from multiple code regions on all processors over the entire execution. Doing this instrumentation naively can, in combination with the application itself, exceed available I/O bandwidth and storage capacity, and can induce severe behavioral perturbations. We present and evaluate a novel technique for scalable, low-error load balance measurement. This uses a parallel wavelet transformmore » and other parallel encoding methods. We show that our technique collects and reconstructs system-wide measurements with low error. Compression time scales sublinearly with system size and data volume is several orders of magnitude smaller than the raw data. The overhead is low enough for online use in a production environment.« less

  14. Simple spatial scaling rules behind complex cities.

    PubMed

    Li, Ruiqi; Dong, Lei; Zhang, Jiang; Wang, Xinran; Wang, Wen-Xu; Di, Zengru; Stanley, H Eugene

    2017-11-28

    Although most of wealth and innovation have been the result of human interaction and cooperation, we are not yet able to quantitatively predict the spatial distributions of three main elements of cities: population, roads, and socioeconomic interactions. By a simple model mainly based on spatial attraction and matching growth mechanisms, we reveal that the spatial scaling rules of these three elements are in a consistent framework, which allows us to use any single observation to infer the others. All numerical and theoretical results are consistent with empirical data from ten representative cities. In addition, our model can also provide a general explanation of the origins of the universal super- and sub-linear aggregate scaling laws and accurately predict kilometre-level socioeconomic activity. Our work opens a new avenue for uncovering the evolution of cities in terms of the interplay among urban elements, and it has a broad range of applications.

  15. Measurement and Characterization of Concentrator Solar Cells II

    NASA Technical Reports Server (NTRS)

    Scheiman, Dave; Sater, Bernard L.; Chubb, Donald; Jenkins, Phillip; Snyder, Dave

    2005-01-01

    Concentrator solar cells are continuing to get more consideration for use in power systems. This interest is because concentrator systems can have a net lower cost per watt in solar cell materials plus ongoing improvements in sun-tracking technology. Quantitatively measuring the efficiency of solar cells under concentration is difficult. Traditionally, the light concentration on solar cells has been determined by using a ratio of the measured solar cell s short circuit current to that at one sun, this assumes that current changes proportionally with light intensity. This works well with low to moderate (<20 suns) concentration levels on "well-behaved" linear cells but does not apply when cells respond superlinearly, current increases faster than intensity, or sublinearly, current increases more slowly than intensity. This paper continues work on using view factors to determine the concentration level and linearity of the solar cell with mathematical view factor analysis and experimental results [1].

  16. Phloretin-induced changes in ion transport across lipid bilayer membranes

    PubMed Central

    1977-01-01

    Phloretin, the aglucone derivative of phlorizin, increases cation conductance and decreases anion conductance in lipid bilayer membranes. In this paper we present evidence that phloretin acts almost exclusively by altering the permeability of the membrane interior and not by modifying the partition of the permanent species between the membrane and the bulk aqueous phases. We base our conclusion on an analysis of the current responses to a senylborate, and the cation complex, peptide PV-K+. These results are consistent with the hypothesis that phloretin decreases the intrinsic positive internal membrane potential but does not modify to a great extent the potential energy minima at the membrane interfaces. Phloretin increases the conductance for the nonactin-K+ complex, but above 10(-5) M the steady- state nonactin-K+ voltage-current curve changes from superlinear to sublinear. These results imply that, above 10(-5) M phloretin, the nonactin-5+ transport across the membrane becomes interfacially limited. PMID:576427

  17. Segmented molecular design of self-healing proteinaceous materials

    NASA Astrophysics Data System (ADS)

    Sariola, Veikko; Pena-Francesch, Abdon; Jung, Huihun; Çetinkaya, Murat; Pacheco, Carlos; Sitti, Metin; Demirel, Melik C.

    2015-09-01

    Hierarchical assembly of self-healing adhesive proteins creates strong and robust structural and interfacial materials, but understanding of the molecular design and structure-property relationships of structural proteins remains unclear. Elucidating this relationship would allow rational design of next generation genetically engineered self-healing structural proteins. Here we report a general self-healing and -assembly strategy based on a multiphase recombinant protein based material. Segmented structure of the protein shows soft glycine- and tyrosine-rich segments with self-healing capability and hard beta-sheet segments. The soft segments are strongly plasticized by water, lowering the self-healing temperature close to body temperature. The hard segments self-assemble into nanoconfined domains to reinforce the material. The healing strength scales sublinearly with contact time, which associates with diffusion and wetting of autohesion. The finding suggests that recombinant structural proteins from heterologous expression have potential as strong and repairable engineering materials.

  18. Segmented molecular design of self-healing proteinaceous materials.

    PubMed

    Sariola, Veikko; Pena-Francesch, Abdon; Jung, Huihun; Çetinkaya, Murat; Pacheco, Carlos; Sitti, Metin; Demirel, Melik C

    2015-09-01

    Hierarchical assembly of self-healing adhesive proteins creates strong and robust structural and interfacial materials, but understanding of the molecular design and structure-property relationships of structural proteins remains unclear. Elucidating this relationship would allow rational design of next generation genetically engineered self-healing structural proteins. Here we report a general self-healing and -assembly strategy based on a multiphase recombinant protein based material. Segmented structure of the protein shows soft glycine- and tyrosine-rich segments with self-healing capability and hard beta-sheet segments. The soft segments are strongly plasticized by water, lowering the self-healing temperature close to body temperature. The hard segments self-assemble into nanoconfined domains to reinforce the material. The healing strength scales sublinearly with contact time, which associates with diffusion and wetting of autohesion. The finding suggests that recombinant structural proteins from heterologous expression have potential as strong and repairable engineering materials.

  19. A Combination of Buprenorphine and Naltrexone Blocks Compulsive Cocaine Intake in Rodents Without Producing Dependence

    PubMed Central

    Wee, Sunmee; Vendruscolo, Leandro F.; Misra, Kaushik K.; Schlosburg, Joel E.; Koob, George F.

    2012-01-01

    Buprenorphine, a synthetic opioid that acts at both μ and κ opioid receptors, can decrease cocaine use in individuals with opioid addiction. However, the potent agonist action of buprenorphine at μ opioid receptors raises its potential for creating opioid dependence in non–opioid-dependent cocaine abusers. Here, we tested the hypothesis that a combination of buprenorphine and naltrexone (a potent μ opioid antagonist with weaker δ and κ antagonist properties) could block compulsive cocaine self-administration without producing opioid dependence. The effects of buprenorphine and various doses of naltrexone on cocaine self-administration were assessed in rats that self-administered cocaine under conditions of either short access (noncompulsive cocaine seeking) or extended access (compulsive cocaine seeking). Buprenorphine alone reproducibly decreased cocaine self-administration. Although this buprenorphine-alone effect was blocked in a dose-dependent manner by naltrexone in both the short-access and the extended-access groups, the combination of the lowest dose of naltrexone with buprenorphine blocked cocaine self-administration in the extended-access group but not in the short-access group. Rats given this low dose of naltrexone with buprenorphine did not exhibit the physical opioid withdrawal syndrome seen in rats treated with buprenorphine alone, and naltrexone at this dose did not block κ agonist–induced analgesia. The results suggest that the combination of buprenorphine and naltrexone at an appropriate dosage decreases compulsive cocaine self-administration with minimal liability to produce opioid dependence and may be useful as a treatment for cocaine addiction. PMID:22875830

  20. A combination of buprenorphine and naltrexone blocks compulsive cocaine intake in rodents without producing dependence.

    PubMed

    Wee, Sunmee; Vendruscolo, Leandro F; Misra, Kaushik K; Schlosburg, Joel E; Koob, George F

    2012-08-08

    Buprenorphine, a synthetic opioid that acts at both μ and κ opioid receptors, can decrease cocaine use in individuals with opioid addiction. However, the potent agonist action of buprenorphine at μ opioid receptors raises its potential for creating opioid dependence in non-opioid-dependent cocaine abusers. Here, we tested the hypothesis that a combination of buprenorphine and naltrexone (a potent μ opioid antagonist with weaker δ and κ antagonist properties) could block compulsive cocaine self-administration without producing opioid dependence. The effects of buprenorphine and various doses of naltrexone on cocaine self-administration were assessed in rats that self-administered cocaine under conditions of either short access (noncompulsive cocaine seeking) or extended access (compulsive cocaine seeking). Buprenorphine alone reproducibly decreased cocaine self-administration. Although this buprenorphine-alone effect was blocked in a dose-dependent manner by naltrexone in both the short-access and the extended-access groups, the combination of the lowest dose of naltrexone with buprenorphine blocked cocaine self-administration in the extended-access group but not in the short-access group. Rats given this low dose of naltrexone with buprenorphine did not exhibit the physical opioid withdrawal syndrome seen in rats treated with buprenorphine alone, and naltrexone at this dose did not block κ agonist-induced analgesia. The results suggest that the combination of buprenorphine and naltrexone at an appropriate dosage decreases compulsive cocaine self-administration with minimal liability to produce opioid dependence and may be useful as a treatment for cocaine addiction.

  1. Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source.

    PubMed

    White, Shane A; Landry, Guillaume; Fonseca, Gabriel Paiva; Holt, Randy; Rusch, Thomas; Beaulieu, Luc; Verhaegen, Frank; Reniers, Brigitte

    2014-06-01

    The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (<50 kV) brachytherapy system used in accelerated partial breast irradiation (APBI). Breast tissue is a heterogeneous tissue in terms of density and composition. Dosimetric calculations of seven APBI patients treated with Axxent were made using a model-based Monte Carlo platform for a number of tissue models and dose reporting methods and compared to TG-43 based plans. A model of the Axxent source, the S700, was created and validated against experimental data. CT scans of the patients were used to create realistic multi-tissue/heterogeneous models with breast tissue segmented using a published technique. Alternative water models were used to isolate the influence of tissue heterogeneity and backscatter on the dose distribution. Dose calculations were performed using Geant4 according to the original treatment parameters. The effect of the Axxent balloon applicator used in APBI which could not be modeled in the CT-based model, was modeled using a novel technique that utilizes CAD-based geometries. These techniques were validated experimentally. Results were calculated using two dose reporting methods, dose to water (Dw,m) and dose to medium (Dm,m), for the heterogeneous simulations. All results were compared against TG-43-based dose distributions and evaluated using dose ratio maps and DVH metrics. Changes in skin and PTV dose were highlighted. All simulated heterogeneous models showed a reduced dose to the DVH metrics that is dependent on the method of dose reporting and patient geometry. Based on a prescription dose of 34 Gy, the average D90 to PTV was reduced by between ~4% and ~40%, depending on the scoring method, compared to the TG-43 result. Peak skin dose is also reduced by 10%-15% due to the absence of backscatter not accounted for in TG-43. The balloon applicator also contributed to the reduced dose. Other ROIs showed a difference depending on the method of dose reporting. TG-186-based calculations produce results that are different from TG-43 for the Axxent source. The differences depend strongly on the method of dose reporting. This study highlights the importance of backscatter to peak skin dose. Tissue heterogeneities, applicator, and patient geometries demonstrate the need for a more robust dose calculation method for low energy brachytherapy sources.

  2. Peptidase inhibitors reduce opiate narcotic withdrawal signs, including seizure activity, in the rat.

    PubMed

    Pinsky, C; Dua, A K; LaBella, F S

    1982-07-15

    Narcotic withdrawal was precipitated by administration of naloxone in a low dose at 2 h after the final dose of morphine in a 9-day dependency-inducing schedule. Withdrawal was characterized by leaps, increased nocifensor activity and by cerebral cortical epileptiform activity, the latter not generally reported to be prominent in narcotic withdrawal. Single large doses of morphine did not provoke epileptiform activity at 2 h postinjection but did induce an acute opioid dependency wherein a moderately high dose of naloxone, ineffective in non-dependent rats, provoked upward leaping and electrocortical epileptiform activity. Pretreatment of the 9-day dependent rats with peptidase inhibitors, administered intracerebroventricularly, significantly reduced withdrawal severity including the epileptiform activity. We propose that peptidase inhibitors protect certain species of endogenous opioids and/or other neuropeptides that tend to suppress expression of the narcotic withdrawal syndrome. Furthermore, our findings suggest that epileptiform activity is a nascent form of cerebral activity hitherto largely unnoticed in narcotic withdrawal and that neuropeptides may be involved in certain epileptic states.

  3. Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams.

    PubMed

    Kadoya, Noriyuki; Shimomura, Kouhei; Kitou, Satoshi; Shiota, Yasuo; Fujita, Yukio; Dobashi, Suguru; Takeda, Ken; Jingu, Keiichi; Matsushita, Haruo; Namito, Yoshihito; Ban, Syuichi; Koyama, Syuji; Tabushi, Katsuyoshi

    2012-10-01

    A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosimetric properties of the RGD, including energy dependence of the dose response, reproducibly, variation in data obtained by the RGD for each energy, and angular dependence in low-energy photons, are discussed. An RGD (GD-301, Asahi Techno Glass Corporation, Shizuoka, Japan) was irradiated with monochromatic low-energy photon beams generated by synchrotron radiation at Photon Factory, High Energy Accelerator Research Organization (KEK). The size of GD-301 was 1.5 mm in diameter and 8.5 mm in length and the active dose readout volume being 1 mm diameter and 0.6 mm depth located 0.7 mm from the end of the detector. The energy dependence of the dose response and reproducibility and variation were investigated for RGDs irradiated with a plastic holder and those irradiated without the plastic holder. Response of the RGD was obtained by not only conventional single field irradiation but also bilateral irradiation. Angular dependence of the RGD was measured in the range of 0°-90° for 13, 17, 40, and 80 keV photon beams by conventional single field irradiation. The dose responses had a peak at around 40 keV. For the energy range of less than 25 keV, all dose response curves steeply decreased in comparison with the ratio of mass energy absorption coefficient of the RGD to that of air. As for the reproducibility and variation in data obtained by the RGD, the coefficient of variance increased with decrease in photon energy. Furthermore, the variation for bilateral irradiation was less than that for single field irradiation. Regarding angular dependence of the RGD, for energies of 13 and 17 keV, the response decreased with increase in the irradiation angle, and the minimum values were 93.5% and 86%, respectively. Our results showed the dosimetric properties of the RGD, including the energy dependence of the dose response, reproducibly, variation, and angular dependence in low-energy photons and suggest that the accuracy of the absorbed dose in low-energy photons is affected by the readout method and the distribution of radiophotoluminescence centers in the RGD.

  4. Intracellular Networks of the PI3K/AKT and MAPK Pathways for Regulating Toxoplasma gondii-Induced IL-23 and IL-12 Production in Human THP-1 Cells

    PubMed Central

    Choi, In-Wook; Ismail, Hassan Ahmed Hassan Ahmed; Zhou, Wei; Cha, Guang-Ho; Zhou, Yu; Yuk, Jae-Min; Jo, Eun-Kyeong; Lee, Young-Ha

    2015-01-01

    Interleukin (IL)-23 and IL-12 are closely related in structure, and these cytokines regulate both innate and adaptive immunity. However, the precise signaling networks that regulate the production of each in Toxoplasma gondii-infected THP-1 monocytic cells, particularly the PI3K/AKT and MAPK signaling pathways, remain unknown. In the present study, T. gondii infection upregulated the expression of IL-23 and IL-12 in THP-1 cells, and both cytokines increased with parasite dose. IL-23 secretion was strongly inhibited by TLR2 monoclonal antibody (mAb) treatment in a dose-dependent manner and by TLR2 siRNA transfection, whereas IL-12 secretion was strongly inhibited by TLR4 mAb treatment dose-dependently and by TLR4 siRNA transfection. IL-23 production was dose-dependently inhibited by the PI3K inhibitors LY294002 and wortmannin, whereas IL-12 production increased dose-dependently. THP-1 cells exposed to live T. gondii tachyzoites underwent rapid p38 MAPK, ERK1/2 and JNK activation. IL-23 production was significantly upregulated by the p38 MAPK inhibitor SB203580 dose-dependently, whereas pretreatment with 10 μM SB203580 significantly downregulated IL-12 production. ERK1/2 inhibition by PD98059 was significantly downregulated IL-23 production but upregulated IL-12 production. JNK inhibition by SP600125 upregulated IL-23 production, but IL-12 production was significantly downregulated dose-dependently. T. gondii infection resulted in AKT activation, and AKT phosphorylation was inhibited dose-dependently after pretreatment with PI3K inhibitors. In T. gondii-infected THP-1 cells, ERK1/2 activation was regulated by PI3K; however, the phosphorylation of p38 MAPK and JNK was negatively modulated by the PI3K signaling pathway. Collectively, these results indicate that IL-23 production in T. gondii-infected THP-1 cells was regulated mainly by TLR2 and then by PI3K and ERK1/2; however, IL-12 production was mainly regulated by TLR4 and then by p38 MAPK and JNK. Our findings provide new insight concerning the intracellular networks of the PI3K/AKT and MAPK signaling cascades for regulating T. gondii-induced IL-23 and IL-12 secretion in human monocytic cells. PMID:26528819

  5. Characterization of commercial MOSFET detectors and their feasibility for in-vivo HDR brachytherapy.

    PubMed

    Phurailatpam, Reena; Upreti, Rituraj; Nojin Paul, Siji; Jamema, Swamidas V; Deshpande, Deepak D

    2016-01-01

    The present study was to investigate the use of MOSFET as an vivo dosimeter for the application of Ir-192 HDR brachytherapy treatments. MOSFET was characterized for dose linearity in the range of 50-1000 cGy, depth dose dependence from 2 to 7 cm, angular dependence. Signal fading was checked for two weeks. Dose linearity was found to be within 2% in the dose range (50-1000 cGy). The response varied within 8.07% for detector-source distance of 2-7 cm. The response of MOSFET with the epoxy side facing the source (0 degree) is the highest and the lowest response was observed at 90 and 270 degrees. Signal was stable during the study period. The detector showed high dose linearity and insignificant fading. But due to angular and depth dependence, care should be taken and corrections must be applied for clinical dosimetry. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. SU-E-T-248: An Extended Generalized Equivalent Uniform Dose Accounting for Dose-Range Dependency of Radio-Biological Parameters.

    PubMed

    Troeller, A; Soehn, M; Yan, D

    2012-06-01

    Introducing an extended, phenomenological, generalized equivalent uniform dose (eEUD) that incorporates multiple volume-effect parameters for different dose-ranges. The generalized EUD (gEUD) was introduced as an estimate of the EUD that incorporates a single, tissue-specific parameter - the volume-effect-parameter (VEP) 'a'. As a purely phenomenological concept, its radio-biological equivalency to a given inhomogeneous dose distribution is not a priori clear and mechanistic models based on radio-biological parameters are assumed to better resemble the underlying biology. However, for normal organs mechanistic models are hard to derive, since the structural organization of the tissue plays a significant role. Consequently, phenomenological approaches might be especially useful in order to describe dose-response for normal tissues. However, the single parameter used to estimate the gEUD may not suffice in accurately representing more complex biological effects that have been discussed in the literature. For instance, radio-biological parameters and hence the effects of fractionation are known to be dose-range dependent. Therefore, we propose an extended phenomenological eEUD formula that incorporates multiple VEPs accounting for dose-range dependency. The eEUD introduced is a piecewise polynomial expansion of the gEUD formula. In general, it allows for an arbitrary number of VEPs, each valid for a certain dose-range. We proved that the formula fulfills required mathematical and physical criteria such as invertibility of the underlying dose-effect and continuity in dose. Furthermore, it contains the gEUD as a special case, if all VEPs are equal to 'a' from the gEUD model. The eEUD is a concept that expands the gEUD such that it can theoretically represent dose-range dependent effects. Its practicality, however, remains to be shown. As a next step, this will be done by estimating the eEUD from patient data using maximum-likelihood based NTCP modelling in the same way it is commonly done for the gEUD. © 2012 American Association of Physicists in Medicine.

  7. SU-E-T-491: Importance of Energy Dependent Protons Per MU Calibration Factors in IMPT Dose Calculations Using Monte Carlo Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Randeniya, S; Mirkovic, D; Titt, U

    2014-06-01

    Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Ofmore » the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.« less

  8. Dose-Dependent Negative Effects of Prior Multiple Vaccinations against Influenza A and Influenza B among School Children: A Study of Kamigoto Island in Japan during the 2011/12, 2012/13 and 2013/14 Influenza Seasons.

    PubMed

    Saito, Nobuo; Komori, Kazuhiro; Suzuki, Motoi; Kishikawa, Takayuki; Yasaka, Takahiro; Ariyoshi, Koya

    2018-03-08

    We investigated the negative effects of prior multiple vaccinations on influenza vaccine effectiveness (VE) and analysed the association of VE with prior vaccine doses. Patients aged 9-18 years presenting with influenza-like illness at a community hospital on a Japanese remote island during the 2011/12, 2012/13 and 2013/14 seasons were tested for influenza using a rapid diagnostic test (RDT). A test-negative case-control study design was used to estimate the VEs of trivalent inactivated influenza vaccine (TIV). Histories of vaccination and medically-attended influenza (MA-flu) A and B during three previous seasons were collected from registry systems. VE was calculated using multi-level mixed-effects logistic regression models adjusted for the history of RDT-confirmed MA-flu. During three influenza seasons, 1668 influenza-like illness episodes were analysed, including 421 and 358 episodes of MA-fluA and MA-fluB, respectively. The adjusted VE yielded significant dose-dependent attenuations by prior vaccinations against both MA-fluA [0 doses during previous three seasons: 96% (95% CI: 69%-100%), 1 dose: 48% (-7% to 74%), 2 doses: 52% (11%-74%), 3 doses: 21% (-25% to 51%); P for trend <0.05] and MA-fluB [0 doses: 66% (-5% to 89%), 1 dose: 48% (-14% to 76%), 2 doses: 34% (-33% to 67%), 3 doses: -7% (-83% to 37%); P for trend <0.05]. After excluding episodes of MA-flu during prior three seasons, similar trends were observed. Repeated previous vaccinations over multiple seasons had significant dose-dependent negative impacts on VE against both MA-fluA and MA-fluB. Further studies to confirm this finding are necessary.

  9. AN EXTRACT OF PENICILLIUM CHRYSOGENUM INDUCES DOSE-DEPENDENT ALLERGIC ASTHMA RESPONSES IN MICE

    EPA Science Inventory

    Rationale: Penicillium chrysogenum, a common indoor mold, is known to have several allergens and can induce allergic responses in a mouse model of allergic penicilliosis. Our hypothesis is that soluble components of P. chrysogenum (PCE) can dose-dependently induce responses typ...

  10. The Role of Endorphins in the Pathophysiology of Hemorrhagic and Endotoxic Shock in the Subhuman Primate.

    DTIC Science & Technology

    1982-09-01

    beneficial effects are dose -dependent,2 independent of blood reinfusion,4 and reproducible by other opiate receptor antagonists. 5 Before embarking on...clinical studies we decided to investigate the mechanisms of action, doses required, and efficacy in a species closer to man. We also thought this was...2 _met 5-enkephalinamide into the third cerebral ventricle of three monkeys produced bradycardia and hypotension which were dose -dependent and

  11. Fibrinolytic activity and dose-dependent effect of incubating human blood clots in caffeic acid phenethyl ester: in vitro assays.

    PubMed

    Elnager, Abuzar; Hassan, Rosline; Idris, Zamzuri; Mustafa, Zulkifli; Wan-Arfah, Nadiah; Sulaiman, S A; Gan, Siew Hua; Abdullah, Wan Zaidah

    2015-01-01

    Background. Caffeic acid phenethyl ester (CAPE) has been reported to possess time-dependent fibrinolytic activity by in vitro assay. This study is aimed at investigating fibrinolytic dose-dependent activity of CAPE using in vitro assays. Methods. Standardized human whole blood (WB) clots were incubated in either blank controls or different concentrations of CAPE (3.75, 7.50, 15.00, 22.50, and 30.00 mM). After 3 hours, D-dimer (DD) levels and WB clot weights were measured for each concentration. Thromboelastography (TEG) parameters were recorded following CAPE incubation, and fibrin morphology was examined under a confocal microscope. Results. Overall, mean DD (μg/mL) levels were significantly different across samples incubated with different CAPE concentrations, and the median pre- and postincubation WB clot weights (grams) were significantly decreased for each CAPE concentration. Fibrin removal was observed microscopically and indicated dose-dependent effects. Based on the TEG test, the Ly30 fibrinolytic parameter was significantly different between samples incubated with two different CAPE concentrations (15.0 and 22.50 mM). The 50% effective dose (ED50) of CAPE (based on DD) was 1.99 mg/mL. Conclusions. This study suggests that CAPE possesses fibrinolytic activity following in vitro incubation and that it has dose-dependent activities. Therefore, further investigation into CAPE as a potential alternative thrombolytic agent should be conducted.

  12. Delayed adverse effects of neonatal exposure to diethylstilbestrol and their dose dependency in female rats.

    PubMed

    Yoshida, Midori; Takahashi, Miwa; Inoue, Kaoru; Hayashi, Seigo; Maekawa, Akihiko; Nishikawa, Akiyoshi

    2011-08-01

    Neonatal exposure to estrogenic chemicals causes irreversible complex damage to the hypothalamus-pituitary-gonadal axis and reproductive system in females. Some lesions are noted after maturation as delayed adverse effects. We investigated the characteristics and dose dependence of delayed effects using female rats neonatally exposed to diethylstilbestrol (DES). Female Donryu rats were subcutaneously injected with a single dose of DES of 0 (control), 0.15, 1.5, 15, 150, or 1,500 µg/kg bw after birth. All except the lowest dose had estrogenic activity in a uterotrophic assay. All rats at 1500 µg/kg and some at 150 µg/kg showed abnormal morphologies in the genital tract, indicating they were androgenized before maturation. Although no morphological abnormalities were noted at 15 µg/kg or lower, onset of persistent estrus was significantly accelerated in the 1.5, 15, and 150 µg/kg groups with dose dependency, and the latest onset was from seventeen to twenty-one weeks of age at 1.5 µg/kg. The neonatal exposure to DES increased uterine adenocarcinoma development only at 150 µg/kg, although uterine anomalies were detected at 1,500 µg/kg. These results indicate that neonatal exposure to DES, which exerts estrogenic activity in vivo, induces delayed adverse effects in female rats in a dose-dependent manner. Early onset of persistent estrus appears to be the most sensitive parameter.

  13. Deferasirox at therapeutic doses is associated with dose-dependent hypercalciuria.

    PubMed

    Wong, Phillip; Polkinghorne, Kevan; Kerr, Peter G; Doery, James C G; Gillespie, Matthew T; Larmour, I; Fuller, Peter J; Bowden, Donald K; Milat, Frances

    2016-04-01

    Deferasirox is an oral iron chelator used widely in the treatment of thalassemia major and other transfusion-dependent hemoglobinopathies. Whilst initial long-term studies established the renal safety of deferasirox, there are now increasing reports of hypercalciuria and renal tubular dysfunction. In addition, urolithiasis with rapid loss of bone density in patients with β thalassemia major has been reported. We conducted a cross-sectional cohort study enrolling 152 adult patients comprising of β thalassemia major (81.5%), sickle cell disease (8%), thalassemia intermedia (2%), HbH disease (6.5%) and E/β thalassemia (2%). Cases were matched with normal control subjects on age, gender and serum creatinine. Iron chelator use was documented and urine calcium to creatinine ratios measured. At the time of analysis, 88.8% of patients were receiving deferasirox and 11.2% were on deferoxamine. Hypercalciuria was present in 91.9% of subjects on deferasirox in a positive dose-dependent relationship. This was not seen with subjects receiving deferoxamine. At a mean dose of 30.2±8.8mg/kg/day, deferasirox was associated with an almost 4 fold increase in urine calcium to creatinine ratio (UCa/Cr). Hypercalciuria was present at therapeutic doses of deferasirox in a dose-dependent manner and warrants further investigation and vigilance for osteoporosis, urolithiasis and other markers of renal dysfunction. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Icosapent ethyl: Eicosapentaenoic acid concentration and triglyceride-lowering effects across clinical studies.

    PubMed

    Bays, Harold E; Ballantyne, Christie M; Doyle, Ralph T; Juliano, Rebecca A; Philip, Sephy

    2016-09-01

    Icosapent ethyl is a high-purity prescription form of eicosapentaenoic acid (EPA) ethyl ester approved at a dose of 4g/day as an adjunct to diet to reduce triglyceride (TG) levels in adult patients with severe (≥500mg/dL) hypertriglyceridemia. This post-hoc exploratory analysis examined the relationship of icosapent ethyl dose with EPA concentrations in plasma and red blood cells (RBCs) across 3 clinical studies-a phase 1 pharmacokinetic study in healthy adult volunteers and 2 pivotal phase 3 studies (MARINE and ANCHOR) in adult patients with hypertriglyceridemia-and examined the relationship between EPA levels and TG-lowering effects in MARINE and ANCHOR. In all 3 studies, icosapent ethyl produced dose-dependent increases in the concentrations of EPA in plasma and RBCs. In both MARINE and ANCHOR, these dose-dependent EPA increases correlated with the degree of TG level lowering (all P<0.01). In patients with high TG levels (≥200mg/dL) and treated with icosapent ethyl 4g/day, the end-of-treatment plasma and RBC EPA concentrations were >170μg/mL and>70μg/mL, respectively. These studies support icosapent ethyl as producing predictable dose-dependent pharmacokinetics/pharmacodynamics, with TG level lowering dependent upon icosapent ethyl dose and EPA concentrations in plasma and RBCs. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Response to varying the nicotine content of cigarettes in vulnerable populations: an initial experimental examination of acute effects.

    PubMed

    Higgins, Stephen T; Heil, Sarah H; Sigmon, Stacey C; Tidey, Jennifer W; Gaalema, Diann E; Stitzer, Maxine L; Durand, Hanna; Bunn, Janice Y; Priest, Jeff S; Arger, Christopher A; Miller, Mollie E; Bergeria, Cecilia L; Davis, Danielle R; Streck, Joanna M; Zvorsky, Ivori; Redner, Ryan; Vandrey, Ryan; Pacek, Lauren R

    2017-01-01

    The purpose of this study was to begin researching the effects of very low nicotine content cigarettes in smokers especially vulnerable to dependence to assess their potential as a less dependence-producing alternative to current commercial cigarettes. Participants were 26 adult, daily cigarette smokers from one of three populations: economically disadvantaged women of reproductive age (n = 9), opioid-dependent individuals (n = 11), and individuals with affective disorders (n = 6). Participants completed fourteen 2-4-h experimental sessions in a within-subjects research design. Sessions were conducted following brief smoking abstinence. Four research cigarettes varying in nicotine content (0.4, 2.4, 5.2, and 15.8 mg/g) were studied under double-blind conditions, assessing smoking topography, subjective effects, and relative reinforcing effects of varying doses in concurrent choice tests. Results were collapsed across vulnerable populations and analyzed using repeated measures ANOVA. No significant differences between doses were discernible in smoking topography. All doses were equi-effective at reducing nicotine withdrawal. Ratings of satisfaction from smoking were lower at the 0.4 compared to 15.8 mg/g dose. Participants preferred the 15.8 mg/g dose over the 0.4 and 2.4 but not the 5.2 mg/g doses in concurrent choice testing; no differences between the two lowest doses were noted. All cigarettes effectively reduced nicotine withdrawal with no differences in smoking topography, suggesting minimal compensatory smoking. Dependence potential was lowest at the 0.4 mg/g dose. These initial results are promising regarding the feasibility of lowering nicotine content in cigarettes to very low levels in vulnerable populations without untoward effects.

  16. Differential dose- and time-dependent effects of molindone on dopamine neurons of rat brain: mediation by irreversible inhibition of monoamine oxidase.

    PubMed

    Meller, E; Friedman, E

    1982-03-01

    The effects of molindone (2.5, 10 and 40 mg/kg) on striatal tyrosine hydroxylase activity and dopamine (DA), 3,4-dihydroxyphenylacetic acid and homovanillic acid levels were measured as a function of time (0-72 hr). Whereas a dose of 2.5 mg/kg produced effects typical of DA receptor blockade (activation of synaptosomal tyrosine hydroxylase, increased DA metabolite levels and unchanged DA levels), a dose of 40 mg/kg produced opposite effects (decreased tyrosine hydroxylase activity and metabolite concentrations and elevated DA levels). A dose of 10 mg/kg elicited intermediate effects. The atypical effects of both higher doses were long-lasting (less than 72 hr). Molindone at doses of 10 or 40 mg/kg, but nor 2.5 mg/kg, selectively, irreversibly and dose-dependently inhibited type A monoamine oxidase. This inhibition appeared to be due to a metabolite, inasmuch as the drug itself inhibited monoamine oxidase (reversibly) only at high concentrations (less than or equal to 10(-4) M). The heretofore unsuspected inhibition of monoamine oxidase by molindone provided a consistent mechanistic interpretation of the differential dose- and time-dependent effects of the drug on dopaminergic neuronal activity. This mechanism may also serve to explain the reported efficacy of molindone in animal tests for antidepressant activity as well as its inability to produce increased DA receptor binding after chronic treatment.

  17. Dose Comparisons for a Site-specific Representative Person Using the Age-dependent Dose Coefficients in CAP88-PC Version 4.

    PubMed

    Stagich, Brooke H; Moore, Kelsey R; Newton, Joseph R; Dixon, Kenneth L; Jannik, G Timothy

    2017-04-01

    Most U.S. Department of Energy (DOE) facilities with radiological airborne releases use the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88-PC to demonstrate compliance with regulations in 40CFR61, subpart H [National Emission Standards for Hazardous Air Pollutants: Radiological (NESHAP)]. In 2015, EPA released Version 4 of CAP88-PC, which included significant modifications that improved usability and age-dependent dose coefficients and usage factors for six age groups (infant, 1 y, 5 y, 10 y, 15 y, and adult). However, EPA has not yet provided specific guidance on how to use these age-dependent factors. For demonstrating compliance with DOE public dose regulations, the Savannah River Site (SRS) recently changed from using the maximally exposed individual (MEI) concept (adult male) to the representative person concept (age- and gender-averaged reference person). In this study, dose comparisons are provided between the MEI and a SRS-specific representative person using the age-specific dose coefficients and usage factors in CAP88-PC V.4. Dose comparisons also are provided for each of the six age groups using five radionuclides of interest at SRS (tritium oxide, Cs, Sr, Pu, and I). In general, the total effective dose increases about 11% for the representative person as compared to the current NESHAP MEI because of the inclusion of the more radiosensitive age groups.

  18. Calculation of Radiation Protection Quantities and Analysis of Astronaut Orientation Dependence

    NASA Technical Reports Server (NTRS)

    Clowdsley, Martha S.; Nealy, John E.; Atwell, William; Anderson, Brooke M.; Luetke, Nathan J.; Wilson, John W.

    2006-01-01

    Health risk to astronauts due to exposure to ionizing radiation is a primary concern for exploration missions and may become the limiting factor for long duration missions. Methodologies for evaluating this risk in terms of radiation protection quantities such as dose, dose equivalent, gray equivalent, and effective dose are described. Environment models (galactic cosmic ray and solar particle event), vehicle/habitat geometry models, human geometry models, and transport codes are discussed and sample calculations for possible lunar and Mars missions are used as demonstrations. The dependence of astronaut health risk, in terms of dosimetric quantities, on astronaut orientation within a habitat is also examined. Previous work using a space station type module exposed to a proton spectrum modeling the October 1989 solar particle event showed that reorienting the astronaut within the module could change the calculated dose equivalent by a factor of two or more. Here the dose equivalent to various body tissues and the whole body effective dose due to both galactic cosmic rays and a solar particle event are calculated for a male astronaut in two different orientations, vertical and horizontal, in a representative lunar habitat. These calculations also show that the dose equivalent at some body locations resulting from a solar particle event can vary by a factor of two or more, but that the dose equivalent due to galactic cosmic rays has a much smaller (<15%) dependence on astronaut orientation.

  19. Opposing roles for GABAA and GABAC receptors in short-term memory formation in young chicks.

    PubMed

    Gibbs, M E; Johnston, G A R

    2005-01-01

    The inhibitory neurotransmitter GABA has both inhibitory and enhancing effects on short-term memory for a bead discrimination task in the young chick. Low doses of GABA (1-3 pmol/hemisphere) injected into the multimodal association area of the chick forebrain, inhibit strongly reinforced memory, whereas higher doses (30-100 pmol/hemisphere) enhance weakly reinforced memory. The effect of both high and low doses of GABA is clearly on short-term memory in terms of both the time of injection and in the time that the memory loss occurs. We argue on the basis of relative sensitivities to GABA and to selective GABA receptor antagonists that low doses of GABA act at GABAC receptors (EC50 approximately 1 microM) and the higher doses of GABA act via GABAA receptors (EC50 approximately 10 microM). The selective GABAA receptor antagonist bicuculline inhibited strongly reinforced memory in a dose and time dependent manner, whereas the selective GABAC receptor antagonists TPMPA and P4MPA enhanced weakly reinforced in a dose and time dependent manner. Confirmation that different levels of GABA affect different receptor subtypes was demonstrated by the shift in the GABA dose-response curves to the selective antagonists. It is clear that GABA is involved in the control of short-term memory formation and its action, enhancing or inhibiting, depends on the level of GABA released at the time of learning.

  20. Effects of systemic carbidopa on dopamine synthesis in rat hypothalamus and striatum

    NASA Technical Reports Server (NTRS)

    Kaakkola, S.; Tuomainen, P.; Wurtman, R. J.; Maennistoe, P. T.

    1991-01-01

    Significant concentrations of carbidopa (CD) were found in rat hypothalamus, striatum, and in striatal microdialysis efflux after intraperitoneal administration of the drug. Efflux levels peaked one hour after administration of 100 mg/kg at 0.37 microg/kg or about 2 percent of serum levels. Concurrent CD levels in hypothalamus and striatum were about 2.5 percent and 1.5 percent, respectively, of corresponding serum levels. Levels of dopamine and its principal metabolites in striatal efflux were unaffected. The removal of the brain blood by saline perfusion decreased the striatal and hypothalamic CD concentrations only by 33 percent and 16 percent, respectively. In other rats receiving both CD and levodopa (LD), brain L-dopa, dopamine, and 3,4-dihydroxyphenvlacetic acid (DOPAC) levels after one hour tended to be proportionate to LD dose. When the LD dose remained constant, increasing the CD dose dose-dependently enhanced L-dopa levels in the hypothalamus and striatum. However, dopamine levels did not increase but, in contrast, decreased dose-dependently (although significantly only in the hypothalamus). CD also caused dose-dependent decrease in striatal 3-O-methyldopa (3-OMD) and in striatal and hypothalamic homovanillic acid (HVA), when the LD dose was 50 mg/kg. We conclude that, at doses exceedimg 50 mg/kg, sufficient quantities of CD enter the brain to inhibit dopamine formation, especially in the hypothalamus. Moreover, high doses of LD/CD, both of which are themselves catechols, can inhibit the O-methylation of brain catecholamines formed from the LD.

  1. Effects of systemic carbidopa on dopamine synthesis in rat hypothalamus and striatum

    NASA Technical Reports Server (NTRS)

    Kaakkola, S.; Tuomainen, P.; Wurtman, R. J.; Mannisto, P. T.

    1992-01-01

    Significant concentrations of carbidopa (CD) were found in rat hypothalamus, striatum, and in striatal microdialysis efflux after intraperitoneal administration of the drug. Efflux levels peaked one hour after administration of 100 mg/kg at 0.37 micrograms/ml, or about 2% of serum levels. Concurrent CD levels in hypothalamus and striatum were about 2.5% and 1.5%, respectively, of corresponding serum levels. Levels of dopamine and its principal metabolites in striatal efflux were unaffected. The removal of the brain blood by saline perfusion decreased the striatal and hypothalamic CD concentrations only by 33% and 16%, respectively. In other rats receiving both CD and levodopa (LD), brain L-dopa, dopamine and 3,4-dihydroxyphenylacetic acid (DOPAC) levels after one hour tended to be proportionate to LD dose. When the LD dose remained constant, increasing the CD dose dose-dependently enhanced L-dopa levels in the hypothalamus and striatum. However dopamine levels did not increase but, in contrast, decreased dose-dependently (although significantly only in the hypothalamus). CD also caused dose-dependent decrease in striatal 3-O-methyldopa (3-OMD) and in striatal and hypothalamic homovanillic acid (HVA), when the LD dose was 50 mg/kg. We conclude that, at doses exceeding 50 mg/kg, sufficient quantities of CD enter the brain to inhibit dopamine formation, especially in the hypothalamus. Moreover, high doses of LD/CD, both of which are themselves catechols, can inhibit the O-methylation of brain catecholamines formed from the LD.

  2. Dose-dependent effects on survival of Salmonella enterica serovar Typhimurium in house flies (Musca domestica L.)

    USDA-ARS?s Scientific Manuscript database

    Adult house flies ingest variable numbers of bacteria when they encounter microbe-rich substrates. Bacterial abundance may affect survival within the fly gut, which subsequently impacts vector potential. This study investigated the dose-dependent survival of GFP-expressing Salmonella enterica serova...

  3. Comparison of Data on Mutation Frequencies of Mice Caused by Radiation with Low Dose Model

    NASA Astrophysics Data System (ADS)

    Manabe, Yuichiro; Bando, Masako

    2013-09-01

    We propose low dose (LD) model, the extension of LDM model which was proposed in the previous paper [Y. Manabe et al.: J. Phys. Soc. Jpn. 81 (2012) 104004] to estimate biological damage caused by irradiation. LD model takes account of cell death effect in addition to the proliferation, apoptosis, repair which were included in LDM model. As a typical example of estimation, we apply LD model to the experiment of mutation frequency on the responses induced by the exposure to low levels of ionizing radiation. The most famous and extensive experiments are those summarized by Russell and Kelly [Proc. Natl. Acad. Sci. U.S.A. 79 (1982) 539], which are known as ``mega-mouse project''. This provides us with important information of the frequencies of transmitted specific-locus mutations induced in mouse spermatogonia stem-cells. It is found that the numerical results of the mutation frequency of mice are in reasonable agreement with the experimental data: the LD model reproduces the total dose and dose rate dependence of data reasonably. In order to see such dose-rate dependence more explicitly, we introduce the dose-rate effectiveness factor (DREF). This represents a sort of dose rate dependent effect, which are to be competitive with proliferation effect of broken cells induced by irradiation.

  4. Study protocol: a dose-escalating, phase-2 study of oral lisdexamfetamine in adults with methamphetamine dependence.

    PubMed

    Ezard, Nadine; Dunlop, Adrian; Clifford, Brendan; Bruno, Raimondo; Carr, Andrew; Bissaker, Alexandra; Lintzeris, Nicholas

    2016-12-01

    The treatment of methamphetamine dependence is a continuing global health problem. Agonist type pharmacotherapies have been used successfully to treat opioid and nicotine dependence and are being studied for the treatment of methamphetamine dependence. One potential candidate is lisdexamfetamine, a pro-drug for dexamphetamine, which has a longer lasting therapeutic action with a lowered abuse potential. The purpose of this study is to determine the safety of lisdexamfetamine in this population at doses higher than those currently approved for attention deficit hyperactivity disorder or binge eating disorder. This is a phase 2 dose escalation study of lisdexamfetamine for the treatment of methamphetamine dependence. Twenty individuals seeking treatment for methamphetamine dependence will be recruited at two Australian drug and alcohol services. All participants will undergo a single-blinded ascending-descending dose regime of 100 to 250 mg lisdexamfetamine, dispensed daily on site, over an 8-week period. Participants will be offered counselling as standard care. For the primary objectives the outcome variables will be adverse events monitoring, drug tolerability and regimen completion. Secondary outcomes will be changes in methamphetamine use, craving, withdrawal, severity of dependence, risk behaviour and other substance use. Medication acceptability, potential for non-prescription use, adherence and changes in neurocognition will also be measured. Determining the safety of lisdexamfetamine will enable further research to develop pharmacotherapies for the treatment of methamphetamine dependence. Australian and New Zealand Clinical Trials Registry ACTRN12615000391572 Registered 28 th April 2015.

  5. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  6. Fast online and index-based algorithms for approximate search of RNA sequence-structure patterns

    PubMed Central

    2013-01-01

    Background It is well known that the search for homologous RNAs is more effective if both sequence and structure information is incorporated into the search. However, current tools for searching with RNA sequence-structure patterns cannot fully handle mutations occurring on both these levels or are simply not fast enough for searching large sequence databases because of the high computational costs of the underlying sequence-structure alignment problem. Results We present new fast index-based and online algorithms for approximate matching of RNA sequence-structure patterns supporting a full set of edit operations on single bases and base pairs. Our methods efficiently compute semi-global alignments of structural RNA patterns and substrings of the target sequence whose costs satisfy a user-defined sequence-structure edit distance threshold. For this purpose, we introduce a new computing scheme to optimally reuse the entries of the required dynamic programming matrices for all substrings and combine it with a technique for avoiding the alignment computation of non-matching substrings. Our new index-based methods exploit suffix arrays preprocessed from the target database and achieve running times that are sublinear in the size of the searched sequences. To support the description of RNA molecules that fold into complex secondary structures with multiple ordered sequence-structure patterns, we use fast algorithms for the local or global chaining of approximate sequence-structure pattern matches. The chaining step removes spurious matches from the set of intermediate results, in particular of patterns with little specificity. In benchmark experiments on the Rfam database, our improved online algorithm is faster than the best previous method by up to factor 45. Our best new index-based algorithm achieves a speedup of factor 560. Conclusions The presented methods achieve considerable speedups compared to the best previous method. This, together with the expected sublinear running time of the presented index-based algorithms, allows for the first time approximate matching of RNA sequence-structure patterns in large sequence databases. Beyond the algorithmic contributions, we provide with RaligNAtor a robust and well documented open-source software package implementing the algorithms presented in this manuscript. The RaligNAtor software is available at http://www.zbh.uni-hamburg.de/ralignator. PMID:23865810

  7. Efficacy and safety of tranexamic acid as an emetic in dogs.

    PubMed

    Kakiuchi, Hitoshi; Kawarai-Shimamura, Asako; Fujii, Yoko; Aoki, Takuma; Yoshiike, Masaki; Arai, Hayato; Nakamura, Atsushi; Orito, Kensuke

    2014-12-01

    To determine dose dependency of tranexamic acid-induced emesis and the time course of the antifibrinolytic potency of tranexamic acid in dogs. 10 Beagles. In a dose-escalating experiment, ascending doses of tranexamic acid (10, 20, and 30 mg/kg, IV) were administered at 5-minute intervals until vomiting was observed. In a separate single-dose experiment, ascending doses of tranexamic acid (20, 30, 40, and 50 mg/kg, IV) were administered at 1-week intervals until vomiting was observed. Time to onset of vomiting and number of vomiting episodes were measured in both experiments. In a coagulation experiment, a single 50 mg/kg bolus of tranexamic acid was administered, and blood was obtained 1 hour before and 20 minutes, 3 hours, and 24 hours after administration. Antifibrinolytic potency of tranexamic acid was evaluated by use of a modified rotational thromboelastography method. Tranexamic acid induced vomiting in a dose-dependent manner. Vomiting frequency was ≤ 2 episodes, and vomiting concluded ≤ 250 seconds after administration. Antifibrinolytic potency of tranexamic acid was significantly higher at 20 minutes following administration, but not different by 24 hours, when compared with the potency measured before administration. No adverse effects were observed in any experiment. IV administration of tranexamic acid induced emesis in a dose-dependent manner. The antifibrinolytic potency of tranexamic acid decreased in a time-dependent manner and was resolved ≤ 24 hours after administration. Further studies are warranted to investigate the emetic and other adverse effects of tranexamic acid in dogs of various breeds and ages.

  8. Dose-dependent EEG effects of zolpidem provide evidence for GABA(A) receptor subtype selectivity in vivo.

    PubMed

    Visser, S A G; Wolters, F L C; van der Graaf, P H; Peletier, L A; Danhof, M

    2003-03-01

    Zolpidem is a nonbenzodiazepine GABA(A) receptor modulator that binds in vitro with high affinity to GABA(A) receptors expressing alpha(1) subunits but with relatively low affinity to receptors expressing alpha(2), alpha(3), and alpha(5) subunits. In the present study, it was investigated whether this subtype selectivity could be detected and quantified in vivo. Three doses (1.25, 5, and 25 mg) of zolpidem were administered to rats in an intravenous infusion over 5 min. The time course of the plasma concentrations was determined in conjunction with the change in the beta-frequency range of the EEG as pharmacodynamic endpoint. The concentration-effect relationship of the three doses showed a dose-dependent maximum effect and a dose-dependent potency. The data were analyzed for one- or two-site binding using two pharmacodynamic models based on 1) the descriptive model and 2) a novel mechanism-based pharmacokinetic/pharmacodynamic (PK/PD) model for GABA(A) receptor modulators that aims to separates drug- and system-specific properties, thereby allowing the estimation of in vivo affinity and efficacy. The application of two-site models significantly improved the fits compared with one-site models. Furthermore, in contrast to the descriptive model, the mechanism-based PK/PD model yielded dose-independent estimates for affinity (97 +/- 40 and 33,100 +/- 14,800 ng x ml(-1)). In conclusion, the mechanism-based PK/PD model is able to describe and explain the observed dose-dependent EEG effects of zolpidem and suggests the subtype selectivity of zolpidem in vivo.

  9. Dose dependence of true stress parameters in irradiated bcc, fcc, and hcp metals

    NASA Astrophysics Data System (ADS)

    Byun, T. S.

    2007-04-01

    The dose dependence of true stress parameters has been investigated for nuclear structural materials: A533B pressure vessel steels, modified 9Cr-1Mo and 9Cr-2WVTa ferritic martensitic steels, 316 and 316LN stainless steels, and Zircaloy-4. After irradiation to significant doses, these alloys show radiation-induced strengthening and often experience prompt necking at yield followed by large necking deformation. In the present work, the critical true stresses for deformation and fracture events, such as yield stress (YS), plastic instability stress (PIS), and true fracture stress (FS), were obtained from uniaxial tensile tests or calculated using a linear strain-hardening model for necking deformation. At low dose levels where no significant embrittlement was detected, the true fracture stress was nearly independent of dose. The plastic instability stress was also independent of dose before the critical dose-to-prompt-necking at yield was reached. A few bcc alloys such as ferritic martensitic steels experienced significant embrittlement at doses above ∼1 dpa; and the true fracture stress decreased with dose. The materials fractured before yield at or above 10 dpa.

  10. Dose and dose rate effects of whole-body proton irradiation on leukocyte populations and lymphoid organs: part I

    NASA Technical Reports Server (NTRS)

    Gridley, Daila S.; Pecaut, Michael J.; Dutta-Roy, Radha; Nelson, Gregory A.

    2002-01-01

    The goal of part I of this study was to evaluate the effects of whole-body proton irradiation on lymphoid organs and specific leukocyte populations. C57BL/6 mice were exposed to the entry region of the proton Bragg curve to total doses of 0.5 gray (Gy), 1.5 Gy, and 3.0 Gy, each delivered at a low dose rate (LDR) of 1 cGy/min and high dose rate (HDR) of 80 cGy/min. Non-irradiated and 3 Gy HDR gamma-irradiated groups were included as controls. At 4 days post-irradiation, highly significant radiation dose-dependent reductions were observed in the mass of both lymphoid organs and the numbers of leukocytes and T (CD3(+)), T helper (CD3(+)/CD4(+)), T cytotoxic (CD3(+)/CD8(+)), and B (CD19(+)) cells in both blood and spleen. A less pronounced dose effect was noted for natural killer (NK1.1(+) NK) cells in spleen. Monocyte, but not granulocyte, counts in blood were highly dose-dependent. The numbers for each population generally tended to be lower with HDR than with LDR radiation; a significant dose rate effect was found in the percentages of T and B cells, monocytes, and granulocytes and in CD4(+):CD8(+) ratios. These data indicate that mononuclear cell response to the entry region of the proton Bragg curve is highly dependent upon the total dose and that dose rate effects are evident with some cell types. Results from gamma- and proton-irradiated groups (both at 3 Gy HDR) were similar, although proton-irradiation gave consistently lower values in some measurements.

  11. 2,3-Butanedione monoxime facilitates successful resuscitation in a dose-dependent fashion in a pig model of cardiac arrest.

    PubMed

    Lee, Byung Kook; Kim, Mu Jin; Jeung, Kyung Woon; Choi, Sung Soo; Park, Sang Wook; Yun, Seong Woo; Lee, Sung Min; Lee, Dong Hun; Min, Yong Il

    2016-06-01

    Ischemic contracture compromises the hemodynamic effectiveness of cardiopulmonary resuscitation (CPR) and resuscitability from cardiac arrest. In a pig model of cardiac arrest, 2,3-butanedione monoxime (BDM) attenuated ischemic contracture. We investigated the effects of different doses of BDM to determine whether increasing the dose of BDM could improve the hemodynamic effectiveness of CPR further, thus ultimately improving resuscitability. After 16minutes of untreated ventricular fibrillation and 8minutes of basic life support, 36 pigs were divided randomly into 3 groups that received 50mg/kg (low-dose group) of BDM, 100mg/kg (high-dose group) of BDM, or an equivalent volume of saline (control group) during advanced cardiovascular life support. During advanced cardiovascular life support, the control group showed an increase in left ventricular (LV) wall thickness and a decrease in LV chamber area. In contrast, the BDM-treated groups showed a decrease in the LV wall thickness and an increase in the LV chamber area in a dose-dependent fashion. Mixed-model analyses of the LV wall thickness and LV chamber area revealed significant group effects and group-time interactions. Central venous oxygen saturation at 3minutes after the drug administration was 21.6% (18.4-31.9), 39.2% (28.8-53.7), and 54.0% (47.5-69.4) in the control, low-dose, and high-dose groups, respectively (P<.001). Sustained restoration of spontaneous circulation was attained in 7 (58.3%), 10 (83.3%), and 12 animals (100%) in the control, low-dose, and high-dose groups, respectively (P=.046). 2,3-Butanedione monoxime administered during CPR attenuated ischemic contracture and improved the resuscitability in a dose-dependent fashion. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Olive oil phenolics are dose-dependently absorbed in humans.

    PubMed

    Visioli, F; Galli, C; Bornet, F; Mattei, A; Patelli, R; Galli, G; Caruso, D

    2000-02-25

    Olive oil phenolic constituents have been shown, in vitro, to be endowed with potent biological activities including, but not limited to, an antioxidant action. To date, there is no information on the absorption and disposition of such compounds in humans. We report that olive oil phenolics, namely tyrosol and hydroxytyrosol, are dose-dependently absorbed in humans after ingestion and that they are excreted in the urine as glucuronide conjugates. Furthermore, an increase in the dose of phenolics administered increased the proportion of conjugation with glucuronide.

  13. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    PubMed

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  14. Gestational age and dose influence on placental transfer of 63Ni in rats.

    PubMed

    Wang, X-W; Gu, J-Y; Li, Z; Song, Y-F; Wu, W-S; Hou, Y-P

    2010-04-01

    The effects of gestational age and dose of nickel exposure on regulating and influencing placental transfer were investigated. Pregnant rats on gestational day (GD) 12, 15 or 20 were injected intraperitoneally with saline, 64,320 or 640 kBq/kg body weight of (63)Ni. Twenty-four hours after administration, samples were harvested from each for measurement of radioactivity by liquid scintillation counting and for autoradiography. In placenta, amniotic fluid and fetal membrane, (63)Ni concentrations increased with increasing doses and gestational age. In fetus, (63)Ni concentrations reached a maximum on GD 15 and then declined on GD 20 although they maintained a dose-dependency for each GD group. In fetal blood on GD 20, (63)Ni concentration increased dose-dependently and was higher than in maternal blood. The autoradiographs demonstrated that (63)Ni radioactivity was located within placental basal lamina, fetal bones and most organs. These findings suggest that the nickel uptake, retention and transport in placenta increase dose- and gestation age-dependently, and nickel transfer through placental barrier is primarily from mother into the fetus, but hardly from fetus to mother. Copyright 2010 Elsevier Ltd. All rights reserved.

  15. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    PubMed

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  16. Long-term dose-dependent response of Mequindox on aldosterone, corticosterone and five steroidogenic enzyme mRNAs in the adrenal of male rats.

    PubMed

    Huang, Xian-Ju; Ihsan, Awais; Wang, Xu; Dai, Meng-Hong; Wang, Yu-Lian; Su, Shi-Jia; Xue, Xi-Juan; Yuan, Zong-Hui

    2009-12-15

    Mequindox (MEQ) is a synthetic quinoxaline 1,4-dioxides (QdNOs) derivative which can effectively improve growth and feed efficiency in animals. This study was to investigate the dose-dependent long-term toxicity in the adrenal of male rats exposed to 180 days of MEQ feed. Our data demonstrated that high doses of MEQ in the diet for 180 days led to adrenal damage and steroid hormone decrease, combined with sodium decrease and potassium increase in rat plasma. Significant changes of GSH and SOD in plasma were observed in the high doses (110, 275 mg/kg) groups. At the same doses, MEQ treatment down-regulated the mRNA levels of CYP11A1, CYP11B1 and CYP11B2 which located in mitochondria, but up-regulated mRNA levels of CYP21 and 3beta-HSD which located in endoplasmic reticulum. In conclusion, we reported the dose-dependent long-term toxicity of MEQ on adrenal gland in male rats, which raise awareness of its toxic effects to animals and consumers, and its mechanism may involve in oxidative stress and steroid hormone biosynthesis pathway.

  17. SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

    PubMed

    Chiu-Tsao, S; Massillon-Jl, G; Domingo-Muñoz, I; Chan, M

    2012-06-01

    To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams were calibrated per AAPM TG-51 protocol while the kilovoltage beam was calibrated following the TG-61 using an ionization chamber calibrated at NIST. Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in transmission mode, landscape orientation, 48-bit color at two separate spatial resolutions of 75 and 300 dpi. The data were analyzed using ImageJ and, for each scanned image, a region of interest (ROI) of 2×2cm 2 at the field center was selected to obtain the mean pixel value with its standard deviation in the ROI. For each energy, dose value and spatial resolution, the average netOD and its associated uncertainty were determined. The Student's t-test was performed to evaluate the statistical differences between the netOD/dose values of the three energy modalities, with different color channels and spatial resolutions. The dose response curves for the three energy modalities were compared in three color channels with 75 and 300dpi. Weak energy dependence was found. For doses above 100cGy, no statistical differences were observed between 6 and 15MV beams, regardless of spatial resolution. However, statistical differences were observed between 50kV and the megavoltage beams. The degree of energy dependence (from MV to 50kV) was found to be function of color channel, dose level and spatial resolution. The dose response curves for GafChromic EBT3 films were found to be weakly dependent on the energy of the photon beams from 6MV to 50kV. The degree of energy dependence varies with color channel, dose and spatial resolution. GafChromic EBT3 films were supplied by Ashland Corp. This work was partially supported by DGAPA-UNAM grant IN102610 and Conacyt Mexico grant 127409. © 2012 American Association of Physicists in Medicine.

  18. Cocoa consumption dose-dependently improves flow-mediated dilation and arterial stiffness decreasing blood pressure in healthy individuals.

    PubMed

    Grassi, Davide; Desideri, Giovambattista; Necozione, Stefano; di Giosia, Paolo; Barnabei, Remo; Allegaert, Leen; Bernaert, Herwig; Ferri, Claudio

    2015-02-01

    Cocoa flavonoids exert beneficial vascular effects and reduce the risk of cardiovascular morbidity and mortality. Nevertheless, the involved mechanisms have not been clarified and no study has yet focused on the dose-response effects. We aimed to investigate the effects of different doses of cocoa flavonoids on flow-mediated dilation (FMD), endothelin-1 (ET-1), pulse wave velocity (PWV), and SBP and DBP. According to a randomized, double-blind, controlled, cross-over design, 20 healthy volunteers (1.5% improvement in FMD in 20 individuals: 0.99 at alpha = 0.05) were assigned to receive either five treatments with daily intake of 10 g cocoa (0, 80, 200, 500 and 800 mg cocoa flavonoids/day) in five periods lasting 1 week each. Cocoa dose-dependently increased FMD from 6.2% (control) to 7.3, 7.6, 8.1 and 8.2% after the different flavonoid doses, respectively (P < 0.0001). Compared with the control, even 80  mg cocoa flavonoids per day increased FMD (P < 0.0001). Cocoa dose-dependently decreased PWV (P < 0.0001). Cocoa intake decreased office blood pressure (BP) (SBP: -4.8 ± 1.03  mmHg, P < 0.0001; DBP: -3.03 ± 1.07 mmHg, P = 0.0011). With respect to control, cocoa ingestion decreased 24-h (P = 0.05) and daytime (P = 0.038) SBP, and 24-h (P = 0.0064), daytime (P = 0.0088) and night-time (P = 0.0352) pulse pressure. Compared with the control, cocoa dose-dependently decreased ET-1 levels [from 17.1 (control) to 15.2, 14.5, 14.2 and 14.1 pg/ml, after the different flavonoid doses, respectively (P for treatment <0.05)]. Compared with the control, significant changes were observed for all doses of flavonoids (ET-1; P < 0.05). Our study showed for the first time that cocoa dose-dependently improved FMD and decreased PWV and ET-1 also by ameliorating office and monitored BP. Our findings are clinically relevant, suggesting cocoa, with very low calorie intake, might be reasonably incorporated into a dietary approach, representing a consistent tool in cardiovascular prevention.

  19. MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X; Morgan, A; Davros, W

    Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash,more » Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup fund from the Cleveland State University.« less

  20. [Studies on the physical dependence liability of chlorphenesin carbamate (author's transl)].

    PubMed

    Sasajima, M; Tarumoto, Y; Aihara, H; Tanaka, Y; Saito, S

    1977-05-01

    Physical dependence liability of chlorphenesin carbamate (CPC) was studied in parallel with phenobarbital-Na (PB). Beagle dogs were used and the overall duration of the experiment was 85 days, i.e. the first dosing period was 42 dyas (6 weeks) in which drugs were repeatedly administered orally once daily, followed by a withdrawal period (7 days), the second dosing period was continued from the 50th-78th day in which the form and schedule of drug administration was as in the first dosing period. The last 79th to 85th days were used for substitution experiments. In both dosing periods, PB but not CPC showed signs of tolerance formation. Severe withdrawal syndrome was observed in PB administered dogs whereas there were no changes of behavior observed in CPC-dogs by withdrawal and substitution procedures, respectively. CPC apparently does not have a physical dependence liability.

  1. Delay discounting of oral morphine and sweetened juice rewards in dependent and non-dependent rats.

    PubMed

    Harvey-Lewis, Colin; Perdrizet, Johnna; Franklin, Keith B J

    2014-07-01

    Opioid-dependent humans are reported to show accelerated delay discounting of opioid rewards when compared to monetary rewards. It has been suggested that this may reflect a difference in discounting of consumable and non-consumable goods not specific to dependent individuals. Here, we evaluate the discounting of similar morphine and non-morphine oral rewards in dependent and non-dependent rats We first tested the analgesic and rewarding effects of our morphine solution. In a second experiment, we assigned rats randomly to either dependent or non-dependent groups that, 30 min after daily testing, received 30 mg/kg subcutaneous dose of morphine, or saline, respectively. Delay discounting of drug-free reward was examined prior to initiation of the dosing regimen. We tested discounting of the morphine reward in half the rats and retested the discounting of the drug-free reward in the other half. All tests were run 22.5 h after the daily maintenance dose. Rats preferred the morphine cocktail to the drug-free solution and consumed enough to induce significant analgesia. The control quinine solution did not produce these effects. Dependent rats discounted morphine rewards more rapidly than before dependence and when compared to discounting drug-free rewards. In non-dependent rats both reward types were discounted similarly. These results show that morphine dependence increases impulsiveness specifically towards a drug reward while morphine experience without dependence does not.

  2. Haloperidol Disrupts Opioid-Antinociceptive Tolerance and Physical Dependence

    PubMed Central

    Yang, Cheng; Chen, Yan; Tang, Lei

    2011-01-01

    Previous studies from our laboratory and others have implicated a critical role of Ca2+/calmodulin-dependent protein kinase II (CaMKII) in opioid tolerance and dependence. Translational research targeting the CaMKII pathway is challenging, if not impossible, because of a lack of selective inhibitors. We discovered in a preliminary study that haloperidol, a butyrophenone antipsychotic drug, inhibited CaMKII, which led us to hypothesize that haloperidol can attenuate opioid tolerance and dependence by inhibiting CaMKII. The hypothesis was tested in two rodent models of opioid tolerance and dependence. Pretreatment with haloperidol (0.2–1.0 mg/kg i.p.) prevented the development of morphine tolerance and dependence in a dose-dependent manner. Short-term treatment with haloperidol (0.06–0.60 mg/kg i.p.) dose-dependently reversed the established morphine-antinociceptive tolerance and physical dependence. Correlating with behavioral effects, pretreatment or short-term treatment with haloperidol dose-dependently inhibited morphine-induced up-regulation of supraspinal and spinal CaMKIIα activity. Moreover, haloperidol given orally was also effective in attenuating morphine-induced CaMKIIα activity, antinociceptive tolerance, and physical dependence. Taken together, these data suggest that haloperidol attenuates opioid tolerance and dependence by suppressing CaMKII activity. Because haloperidol is a clinically used drug that can be taken orally, we propose that the drug may be of use in attenuating opioid tolerance and dependence. PMID:21436292

  3. Comparison of composite prostate radiotherapy plan doses with dependent and independent boost phases.

    PubMed

    Narayanasamy, Ganesh; Avila, Gabrielle; Mavroidis, Panayiotis; Papanikolaou, Niko; Gutierrez, Alonso; Baacke, Diana; Shi, Zheng; Stathakis, Sotirios

    2016-09-01

    Prostate cases commonly consist of dual phase planning with a primary plan followed by a boost. Traditionally, the boost phase is planned independently from the primary plan with the risk of generating hot or cold spots in the composite plan. Alternatively, boost phase can be planned taking into account the primary dose. The aim of this study was to compare the composite plans from independently and dependently planned boosts using dosimetric and radiobiological metrics. Ten consecutive prostate patients previously treated at our institution were used to conduct this study on the Raystation™ 4.0 treatment planning system. For each patient, two composite plans were developed: a primary plan with an independently planned boost and a primary plan with a dependently planned boost phase. The primary plan was prescribed to 54 Gy in 30 fractions to the primary planning target volume (PTV1) which includes prostate and seminal vesicles, while the boost phases were prescribed to 24 Gy in 12 fractions to the boost planning target volume (PTV2) that targets only the prostate. PTV coverage, max dose, median dose, target conformity, dose homogeneity, dose to OARs, and probabilities of benefit, injury, and complication-free tumor control (P+) were compared. Statistical significance was tested using either a 2-tailed Student's t-test or Wilcoxon signed-rank test. Dosimetrically, the composite plan with dependent boost phase exhibited smaller hotspots, lower maximum dose to the target without any significant change to normal tissue dose. Radiobiologically, for all but one patient, the percent difference in the P+ values between the two methods was not significant. A large percent difference in P+ value could be attributed to an inferior primary plan. The benefits of considering the dose in primary plan while planning the boost is not significant unless a poor primary plan was achieved.

  4. SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, F; Chofor, N; Schoenfeld, A

    2016-06-15

    Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, themore » energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can be verified or even determined by measurement in a water phantom and comparison with dose distributions calculated using the TG43 dosimetry formalism. Project is supported by DIN Deutsches Institut fuer Normung.« less

  5. Glucose and insulin do not decrease in a dose-dependent manner after increasing doses of mixed fibers that are consumed in muffins for breakfast.

    PubMed

    Willis, Holly J; Thomas, William; Eldridge, Alison L; Harkness, Laura; Green, Hilary; Slavin, Joanne L

    2011-01-01

    Conventional wisdom suggests that fiber consumption leads to lower postprandial glucose and insulin response. We hypothesized that increasing doses of mixed, viscous fiber would lower glucose and insulin levels in a dose-dependent manner. Healthy men (n = 10) and women (n = 10) with a body mass index of 24 ± 2 (mean ± SEM) participated in this double-blind, crossover study. On 4 separate visits, fasting subjects consumed an approximately 2093 kJ (500 calorie) muffin with 0, 4, 8, or 12 g of mixed fibers. Blood was drawn to measure glucose and insulin at regular intervals throughout a 3-hour test period. Area under the curve (AUC) glucose was significantly lower after 0 g of fiber than after 4, 8, or 12 g of fiber (arbitrary AUC units ± SEM: 25.3 ± 5.2 vs 44.6 ± 7.7, 49.7 ± 7.9, 51.5 ± 6.6, respectively; P < .006). Area under the curve glucose increased with increasing fiber doses (P for trend = .0003). Area under the curve insulin was higher after the 4-g dose than after the 0-, 8-, and 12-g doses (arbitrary AUC units ± SEM: 84.4 ± 8.0 vs 60.1 ± 6.5, 69.4 ± 8.7, 69.7 ± 8.5, respectively; P < .05); it did not change in a dose-dependent manner. Area under the curve glucose and AUC insulin did not correlate with each other. Glucose and insulin did not decrease in a dose-dependent manner after 0, 4, 8, and 12 g of mixed fibers were consumed in muffins for breakfast. The lack of differences was largely based on the individual variation in glucose response. Caution should be used when making general claims about the expected impact of fiber on glucose and insulin levels. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Hypothyroidism after Radiation Therapy for Childhood Cancer: A Report from the Childhood Cancer Survivor Study.

    PubMed

    Inskip, Peter D; Veiga, Lene H S; Brenner, Alina V; Sigurdson, Alice J; Ostroumova, Evgenia; Chow, Eric J; Stovall, Marilyn; Smith, Susan A; Weathers, Rita E; Leisenring, Wendy; Robison, Leslie L; Armstrong, Gregory T; Sklar, Charles A; Lubin, Jay H

    2018-05-15

    While thyroid cancer risks from exposure to ionizing radiation early in life are well characterized quantitatively, the association of radiation with nonmalignant, functional thyroid disorders has been less studied. Here, we report on a risk analysis study of hypothyroidism with radiation dose to the thyroid gland and the hypothalamic-pituitary axis among survivors of childhood cancer. Utilizing data from the Childhood Cancer Survivor Study, a cohort of 14,364 five-year survivors of childhood cancer diagnosed at 26 hospitals in the U.S. and Canada between 1970 and 1986 and followed through 2009, the occurrence of hypothyroidism was ascertained among 12,015 survivors through serial questionnaires. Radiation doses to the thyroid gland and pituitary gland were estimated from radiotherapy records. Binary outcome regression was used to estimate prevalence odds ratios for hypothyroidism at five years from diagnosis of childhood cancer and Poisson regression to model incidence rate ratios (RR) after the first five years. A total of 1,193 cases of hypothyroidism were observed, 777 (65%) of which occurred five or more years after cancer diagnosis. The cumulative proportion affected with hypothyroidism (prevalence at five years after cancer diagnosis plus incidence through 30 years after cancer diagnosis) was highest among five-year survivors of Hodgkin lymphoma (32.3%; 95% CI: 29.5-34.9) and cancers of the central nervous system (17.7%; 95% CI: 15.2-20.4). The incidence rate was significantly associated with radiation dose to the thyroid and pituitary. The joint association of hypothyroidism with thyroid and pituitary dose was sub-additive for pituitary doses greater than 16 Gy. In particular, a very strong thyroid radiation dose dependence at low-to-moderate pituitary/hypothalamic doses was diminished at high pituitary doses. Radiation-related risks were higher in males than females and inversely associated with age at exposure and time since exposure but remained elevated more than 25 years after exposure. Our findings indicated that hypothyroidism was significantly associated with treatment with bleomycin (RR = 3.4; 95% CI: 1.6-7.3) and the alkylating agents cyclohexyl-chloroethyl-nitrosourea (CCNU) (RR = 3.0; 95% CI: 1.5-5.3) and cyclophosphamide (RR = 1.3; 95% CI: 1.0-1.8), with a significant dose response for CCNU ( P < 0.01). The risk of hypothyroidism among childhood cancer survivors treated with radiation depends both on direct, dose-dependent radiation-induced damage to the thyroid gland and on dose-dependent indirect effects secondary to irradiation of the hypothalamic-pituitary axis. The dose-response relationship for each site depends on dose to the other. Radiation-related risk persists for more than 25 years after treatment. Treatment with certain chemotherapy agents may increase the risk of hypothyroidism.

  7. Use of radiation protraction to escalate biologically effective dose to the treatment target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuperman, V. Y.; Spradlin, G. S.; Department of Mathematics, Embry-Riddle University, Daytona Beach, Florida 32114

    2011-12-15

    Purpose: The aim of this study is to evaluate how simultaneously increasing fraction time and dose per fraction affect biologically effective dose for the target (BED{sub tar}) while biologically effective dose for the normal tissue (BED{sub nt}) is fixed. Methods: In this investigation, BED{sub tar} and BED{sub nt} were studied by assuming mono-exponential repair of sublethal damage with tissue dependent repair half-time. Results: Our results demonstrate that under certain conditions simultaneously increasing fraction time and dose per fraction result in increased BED{sub tar} while BED{sub nt} is fixed. The dependence of biologically effective dose on fraction time is influenced bymore » the dose rate. In this investigation we analytically determined time-varying dose rate R-tilde which minimizes BED. Changes in BED with fraction time were compared for constant dose rate and for R-tilde. Conclusions: A number of recent experimental and theoretical studies have demonstrated that slow delivery of radiation (known as radiation protraction) leads to reduced therapeutic effect because of increased repair of sublethal damage. In contrast, our analysis shows that under certain conditions simultaneously increasing fraction time and dose per fraction are radiobiologically advantageous.« less

  8. Comparative dosimetric characterization for different types of detectors in high-energy electron beams

    NASA Astrophysics Data System (ADS)

    Lee, Chang Yeol; Kim, Woo Chul; Kim, Hun Jeong; Huh, Hyun Do; Park, Seungwoo; Choi, Sang Hyoun; Kim, Kum Bae; Min, Chul Kee; Kim, Seong Hoon; Shin, Dong Oh

    2017-02-01

    The purpose of this study is to perform a comparison and on analysis of measured dose factor values by using various commercially available high-energy electron beam detectors to measure dose profiles and energy property data. By analyzing the high-energy electron beam data from each detector, we determined the optimal detector for measuring electron beams in clinical applications. The dose linearity, dose-rate dependence, percentage depth dose, and dose profile of each detector were measured to evaluate the dosimetry characteristics of high-energy electron beams. The dose profile and the energy characteristics of high-energy electron beams were found to be different when measured by different detectors. Through comparison with other detectors based on the analyzed data, the microdiamond detector was found to have outstanding dose linearity, a low dose-rate dependency, and a small effective volume. Thus, this detector has outstanding spatial resolution and is the optimal detector for measuring electron beams. Radiation therapy results can be improved and related medical accidents can be prevented by using the procedure developed in this research in clinical practice for all beam detectors when measuring the electron beam dose.

  9. Verbenone: Dose-Dependent Interruption of Pheromone-Based Attraction of Three Sympatric Species of Pine Bark Beetles (Coleoptera: Scolytidae)

    Treesearch

    Daniel R. Miller; John H. Borden; B. Staffan Lindgren

    1995-01-01

    Verbenone significantly reduced catches of Ips latidens (LeConte), I. pini (Say), and Dendroctonus ponderosae Hopkins in multiple-funnel traps, baited with aggregation pheromones, in stands of lodgepole pine in southern British Columbia. Interruption of attraction was dose dependent for all three species. There...

  10. Dose-dependent pheromone responses of mountain pine beetle in stands of lodgepole pine

    Treesearch

    Daniel R. Miller; B. Staffan Lindgren; John H. Borden

    2005-01-01

    We conducted seven behavioral choice tests with Lindgren multiple-funnel traps in stands of mature lodgepole pine in British Columbia, from 1988 to 1994, to determine the dosedependent responses of the mountain pine beetle, Dendroctonus ponderosae Hopkins, to its pheromones. Amultifunctional dose-dependent response was exhibited by D. ...

  11. DEHP (DI-N-ETHYLHEXYL PHTHALATE), WHEN ADMINISTERED DURING SEXUAL DIFFERENTIATION, INDUCES DOSE DEPENDENT DECREASES IN FETAL TESTIS GENE EXPRESSION AND STEROID HORMONE SYNTHESIS

    EPA Science Inventory

    DEHP (di-n-ethylhexyl phthalate), when administered during sexual differentiation, induces dose dependent decreases in fetal testis gene expression and steroid hormone synthesis.
    Vickie S. Wilson, Christy Lambright, Johnathan Furr, Kathy Bobseine, Carmen Wood, Gary Held, and ...

  12. High but not low ECS stimulus intensity augments apomorphine-stimulated dopamine postsynaptic receptor functioning in rats.

    PubMed

    Andrade, Chittaranjan; Srinivasamurthy, Gurunath M; Vishwasenani, A; Prakash, G Sai; Srihari, B S; Chandra, J Suresh

    2002-06-01

    Clinical research shows that the antidepressant and cognitive adverse effects of electroconvulsive therapy are both dependent on the administered electrical stimulus intensity (dose); however, dose-dependent neurotransmitter system changes in the brain, which might underlie the therapeutic or adverse effects, remain to be demonstrated. We used a behavioral model to examine dose-related effects of electroconvulsive shock (ECS) on dopamine postsynaptic receptor functioning in the rat brain. In a factorially designed study, rats (n = 100) were treated with five once-daily ECSs at three levels (sham ECS, 30 mC ECS, and 120 mC ECS), and with drug at two levels (saline, and 1 mg/kg s.c. apomorphine). Motility was assessed in the small open field. Apomorphine-elicited, dopamine postsynaptic receptor-mediated hypermotility was significantly increased by 120 mC ECS but not by 30 mC ECS. An additional but unrelated finding was that, while the ECS seizure duration expectedly decreased across time, no dose-dependent effects were observed. ECS-induced dopamine postsynaptic receptor up-regulation may depend on the intensity of the administered electrical stimulus.

  13. [Drug dependence test on a cerebral insufficiency improver, aniracetam].

    PubMed

    Kuwahara, A; Kubota, A; Hakkei, M; Nakamura, K

    1987-01-01

    Aniracetam, 1-p-anisoyl-2-pyrrolidinone, is known to be a nootropic or cognitive activator. Aniracetam protects against memory and learning deficits without causing effects on motor function and the autonomic nervous system. A drug dependence study on aniracetam utilizing the intragastric route of administration was performed in male cynomolgus monkeys. The behavioral observation test after acute administration revealed that aniracetam at the dose of 25-400 mg/kg did not change the gross behavior. In the self-administration initiation test, animals were exposed to two or three unit doses of aniracetam and references for a total available period of 7 weeks. Aniracetam at the dose of 25, 50 and 75 mg/kg/injection did not initiate self-administration in the respective group of 4, 4 and 2 animals. In the study with d-methamphetamine hydrochloride at the dose of 0.1 mg/kg/injection, 1 out of 4 animals started to consistently self-administer the drug. Self-administration of cocaine hydrochloride at the dose of 10 mg/kg/injection was confirmed in 3 out of 5 animals, and these 3 animals died from overdosing later. In the physical dependence direct induction test, animals received aniracetam (50 mg/kg) and sodium pentobarbital (25 mg/kg: the dose inducing intermediate CNS depression) intragastrically twice a day for 31 consecutive days. Abrupt withdrawal of aniracetam did not elicit abstinent signs (including changes in appetite and body weight) in all 6 animals, whereas withdrawal of pentobarbital produced typical abstinent behavioral signs and decreases in appetite and body weight. In conclusion, aniracetam was confirmed to develop neither physical dependence nor psychic dependence in cynomolgus monkeys.

  14. Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renaud, James; Seuntjens, Jan; Sarfehnia, Arman

    Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question usingmore » an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.« less

  15. SU-E-T-159: Characteristics of Fiber-Optic Radiation Sensor for Proton Therapeutic Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Son, J; Kim, M; Hwang, U

    Purpose: A fiber-optic radiation sensor using Cerenkov radiation has been widely studied for use as a dosimeter for proton therapeutic beam. Although the fiber-optic radiation sensor has already been investigated for proton therapeutic, it has been examined relatively little work for clinical therapeutic proton beams. In this study, we evaluated characteristics of a fiber-optic radiation sensor for clinical therapeutic proton beams. We experimentally evaluated dose-rate dependence, dose response and energy dependence for the proton beam. Methods: A fiber-optic radiation sensor was placed in a water phantom. Beams with energies of low, middle and high were used in the passively-scattered protonmore » therapeutic beam at the National Cancer Center in Korea. The sensor consists of two plastic optical fibers (POF). A reference POF and 2 cm longer POF were used to utilize the subtraction method for having sensitive volume. Each POF is optically coupled to the Multi-Anode Photo Multiplier Tube (MAPMT) and the MAPMT signals are processed using National Instruments Data Acquisition System (NI-DAQ). We were investigated dosimetric properties including dose-rate dependence, dose response and energy dependence. Results: We have successfully evaluated characteristics of a fiber optic radiation sensor using Cerenkov radiation. The fiber-optic radiation sensor showed the dose response linearity and low energy dependence. In addition, as the dose-rate was increased, Cerenkov radiation increased linearly. Conclusion: We evaluated the basic characteristics of the fiber optic radiation sensor, the dosimetry tool, to raise the quality of proton therapy. Based on the research, we developed a real time dosimetry system of the optic fiber to confirm the real time beam position and energy for therapeutic proton pencil beam.« less

  16. Cerebral Cortex Regions Selectively Vulnerable to Radiation Dose-Dependent Atrophy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seibert, Tyler M.; Karunamuni, Roshan; Kaifi, Samar

    Purpose and Objectives: Neurologic deficits after brain radiation therapy (RT) typically involve decline in higher-order cognitive functions such as attention and memory rather than sensory defects or paralysis. We sought to determine whether areas of the cortex critical to cognition are selectively vulnerable to radiation dose-dependent atrophy. Methods and Materials: We measured change in cortical thickness in 54 primary brain tumor patients who underwent fractionated, partial brain RT. The study patients underwent high-resolution, volumetric magnetic resonance imaging (T1-weighted; T2 fluid-attenuated inversion recovery, FLAIR) before RT and 1 year afterward. Semiautomated software was used to segment anatomic regions of the cerebral cortex formore » each patient. Cortical thickness was measured for each region before RT and 1 year afterward. Two higher-order cortical regions of interest (ROIs) were tested for association between radiation dose and cortical thinning: entorhinal (memory) and inferior parietal (attention/memory). For comparison, 2 primary cortex ROIs were also tested: pericalcarine (vision) and paracentral lobule (somatosensory/motor). Linear mixed-effects analyses were used to test all other cortical regions for significant radiation dose-dependent thickness change. Statistical significance was set at α = 0.05 using 2-tailed tests. Results: Cortical atrophy was significantly associated with radiation dose in the entorhinal (P=.01) and inferior parietal ROIs (P=.02). By contrast, no significant radiation dose-dependent effect was found in the primary cortex ROIs (pericalcarine and paracentral lobule). In the whole-cortex analysis, 9 regions showed significant radiation dose-dependent atrophy, including areas responsible for memory, attention, and executive function (P≤.002). Conclusions: Areas of cerebral cortex important for higher-order cognition may be most vulnerable to radiation-related atrophy. This is consistent with clinical observations that brain radiation patients experience deficits in domains of memory, executive function, and attention. Correlations of regional cortical atrophy with domain-specific cognitive functioning in prospective trials are warranted.« less

  17. Objective assessment of gait in xylazine-induced ataxic horses.

    PubMed

    Nout-Lomas, Y S; Page, K M; Kang, H G; Aanstoos, M E; Greene, H M

    2017-05-01

    There is poor agreement between observers of equine neurological gait abnormalities using the modified Mayhew grading scale. To stimulate a dose-dependent ataxia in horses through xylazine administration and identify quantifiable relevant gait parameters. Balanced, randomised, 2-way crossover design. Eight horses were assessed before and after administration of xylazine (low dose and high dose). Gait analyses performed before and after xylazine administration included: 1) kinematic data collected on an equine high-speed treadmill (flat and 10% decline) and from accelerometers placed on head and sacrum; and 2) kinetic data collected on a force plate. All horses developed dose-dependent ataxia. Horses developed a dose-dependent increased stride time, stride length, and time of contact (P<0.0001), and a decreased stride frequency (P<0.0002) after administration of xylazine. Although pelvic acceleration increased in the mediolateral direction (P<0.05) in horses walked on the treadmill, this movement decreased when walking over ground after administration of xylazine (P<0.05). Furthermore, centre of pressure and path length indices changed significantly in horses following administration of xylazine (P<0.05). This study examined one breed of horse (Arabian), all of similar height and weight. Accelerometers were attached to skin, not bone; no correction was made for artefacts from skin displacement. The sedative drug effect is of certain duration, limiting the data collection period. Administration of xylazine induced a dose-dependent ataxia in horses and resulted in significant changes of gait parameters, pelvic accelerations, and stabilographic variables, some of which changed in a dose-dependent fashion. Some of the altered gait parameters in this model were probably a result of overall slowing down of the stride cycle secondary to the sedative effect. Continued efforts to discover and evaluate quantifiable gait parameters that are susceptible to change following development of clinical neurological disease in horses is warranted. © 2016 EVJ Ltd.

  18. Exposure time independent summary statistics for assessment of drug dependent cell line growth inhibition.

    PubMed

    Falgreen, Steffen; Laursen, Maria Bach; Bødker, Julie Støve; Kjeldsen, Malene Krag; Schmitz, Alexander; Nyegaard, Mette; Johnsen, Hans Erik; Dybkær, Karen; Bøgsted, Martin

    2014-06-05

    In vitro generated dose-response curves of human cancer cell lines are widely used to develop new therapeutics. The curves are summarised by simplified statistics that ignore the conventionally used dose-response curves' dependency on drug exposure time and growth kinetics. This may lead to suboptimal exploitation of data and biased conclusions on the potential of the drug in question. Therefore we set out to improve the dose-response assessments by eliminating the impact of time dependency. First, a mathematical model for drug induced cell growth inhibition was formulated and used to derive novel dose-response curves and improved summary statistics that are independent of time under the proposed model. Next, a statistical analysis workflow for estimating the improved statistics was suggested consisting of 1) nonlinear regression models for estimation of cell counts and doubling times, 2) isotonic regression for modelling the suggested dose-response curves, and 3) resampling based method for assessing variation of the novel summary statistics. We document that conventionally used summary statistics for dose-response experiments depend on time so that fast growing cell lines compared to slowly growing ones are considered overly sensitive. The adequacy of the mathematical model is tested for doxorubicin and found to fit real data to an acceptable degree. Dose-response data from the NCI60 drug screen were used to illustrate the time dependency and demonstrate an adjustment correcting for it. The applicability of the workflow was illustrated by simulation and application on a doxorubicin growth inhibition screen. The simulations show that under the proposed mathematical model the suggested statistical workflow results in unbiased estimates of the time independent summary statistics. Variance estimates of the novel summary statistics are used to conclude that the doxorubicin screen covers a significant diverse range of responses ensuring it is useful for biological interpretations. Time independent summary statistics may aid the understanding of drugs' action mechanism on tumour cells and potentially renew previous drug sensitivity evaluation studies.

  19. Exposure time independent summary statistics for assessment of drug dependent cell line growth inhibition

    PubMed Central

    2014-01-01

    Background In vitro generated dose-response curves of human cancer cell lines are widely used to develop new therapeutics. The curves are summarised by simplified statistics that ignore the conventionally used dose-response curves’ dependency on drug exposure time and growth kinetics. This may lead to suboptimal exploitation of data and biased conclusions on the potential of the drug in question. Therefore we set out to improve the dose-response assessments by eliminating the impact of time dependency. Results First, a mathematical model for drug induced cell growth inhibition was formulated and used to derive novel dose-response curves and improved summary statistics that are independent of time under the proposed model. Next, a statistical analysis workflow for estimating the improved statistics was suggested consisting of 1) nonlinear regression models for estimation of cell counts and doubling times, 2) isotonic regression for modelling the suggested dose-response curves, and 3) resampling based method for assessing variation of the novel summary statistics. We document that conventionally used summary statistics for dose-response experiments depend on time so that fast growing cell lines compared to slowly growing ones are considered overly sensitive. The adequacy of the mathematical model is tested for doxorubicin and found to fit real data to an acceptable degree. Dose-response data from the NCI60 drug screen were used to illustrate the time dependency and demonstrate an adjustment correcting for it. The applicability of the workflow was illustrated by simulation and application on a doxorubicin growth inhibition screen. The simulations show that under the proposed mathematical model the suggested statistical workflow results in unbiased estimates of the time independent summary statistics. Variance estimates of the novel summary statistics are used to conclude that the doxorubicin screen covers a significant diverse range of responses ensuring it is useful for biological interpretations. Conclusion Time independent summary statistics may aid the understanding of drugs’ action mechanism on tumour cells and potentially renew previous drug sensitivity evaluation studies. PMID:24902483

  20. Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA.

    PubMed

    Chaswal, Vibha; Weldon, Michael; Gupta, Nilendu; Chakravarti, Arnab; Rong, Yi

    2014-07-08

    We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric-modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle, and couch insertion. Scatter dose characterization, consistency and symmetry of response, and dosimetry accuracy evaluation for fixed aperture arcs and clinical VMAT patient plans were also investigated. All the evaluation tests were performed with the central plug inserted and the homogeneous PMMA density value. Results of gamma analysis demonstrated an overall agreement between ArcCHECK-measured and TPS-calculated reference doses. The diode based field size dependency was found to be within 0.5% of the reference. The dose rate-based dependency was well within 1% of the TPS reference, and the angular dependency was found to be ± 3% of the reference, as tested for BEV angles, for both beams. Dosimetry of fixed arcs, using both narrow and wide field widths, resulted in clinically acceptable global gamma passing rates on the 3%/3mm level and 10% threshold. Dosimetry of narrow arcs showed an improvement over published literature. The clinical VMAT cases demonstrated high level of dosimetry accuracy in gamma passing rates.

  1. Dose-dependent bioavailability indicators for curcumin and two of its novel derivatives.

    PubMed

    Abd el Aziz, Mohamed; El-Asmer, Mohamed; Rezq, Ameen; Al-Malki, Abdulrahman; Kumosani, Taha; Fouad, Hanan; Ahmed, Hanan; Taha, Fatma; Hassouna, Amira; Hafez, Hafez

    2014-01-01

    Novel water-soluble curcumin derivatives have been developed to overcome low in vivo bioavailability of curcumin. The aim of this work is to assess the potential utility of certain downstream targets as bioavailability indicators of systemic activity of pure curcumin and two novel water-soluble curcumin derivatives (NCD) by constructing dose-dependent response curves and to prove whether this novel curcumin derivatives retained, improved, or abolished biological activity of pure curcumin when applied in vivo. Pure curcumin (CUR), curcumin-carboxy derivative (NCD-1), and curcumin protein conjugate (NCD-2) were administered orally to rats at escalating doses: 37, 74, 148, and 296 μM/kg body weight, respectively. Plasma levels of GST activity, cavernous tissue levels of cGMP, and enzymatic activity of both HO-1 and GST were assessed one and half and 24 hours after oral administration of curcumin formulae. This study showed that there was a progressive elevation of cavernous tissue levels of cGMP and enzymatic activity of both HO-1 and GST in a dose-dependent manner that was maintained for 24 h with CUR, NCD-1, and NCD-2. Plasma GST activity was decreased by the lowest doses on the curve. The three dose-dependent bioavailability indicators as surrogates of curcumin and two of its novel derivatives are valid in the studied range of concentration and extended time. The novel curcumin derivatives still conserve with improvement the biological activity of natural curcumin when applied in vivo. © 2013 International Union of Biochemistry and Molecular Biology.

  2. Using [11C]diprenorphine to image opioid receptor occupancy by methadone in opioid addiction: clinical and preclinical studies.

    PubMed

    Melichar, Jan K; Hume, Susan P; Williams, Tim M; Daglish, Mark R C; Taylor, Lindsay G; Ahmad, Rabia; Malizia, Andrea L; Brooks, David J; Myles, Judith S; Lingford-Hughes, Anne; Nutt, David J

    2005-01-01

    Substitute methadone prescribing is one of the main modes of treatment for opioid dependence with established evidence for improved health and social outcomes. However, the pharmacology underpinning the effects of methadone is little studied despite controversies about dosing in relation to outcome. We therefore examined the relationship between methadone dose and occupation of opioid receptors in brain using the positron emission tomography (PET) radioligand [(11)C]diprenorphine in humans and rats. Eight opioid-dependent subjects stable on their substitute methadone (18-90 mg daily) had an [(11)C]diprenorphine PET scan at predicted peak plasma levels of methadone. These were compared with eight healthy controls. No difference in [(11)C]diprenorphine binding was found between the groups, with no relationship between methadone dose and occupancy. Adult male Sprague-Dawley rats that had been given an acute i.v. injection of methadone hydrochloride (0.35, 0.5, 0.7, or 1.0 mg kg(-1)) before [(11)C]diprenorphine showed a dose-dependent increase in biodistribution but no reduction in [(11)C]diprenorphine binding. We suggest that the lack of a dose-dependent relationship between methadone dose, either given chronically in human or acutely in rat, and occupancy of opioid receptor measured with [(11)C]diprenorphine PET is related to efficacy of this opioid agonist at very low levels of opioid receptor occupancy. This has implications for understanding the actions of methadone in comparison with other opioid drugs such as partial agonists and antagonists.

  3. Characterization of the a-Si EPID in the unity MR-linac for dosimetric applications.

    PubMed

    Torres-Xirau, I; Olaciregui-Ruiz, I; Baldvinsson, G; Mijnheer, B J; van der Heide, U A; Mans, A

    2018-01-09

    Electronic portal imaging devices (EPIDs) are frequently used in external beam radiation therapy for dose verification purposes. The aim of this study was to investigate the dose-response characteristics of the EPID in the Unity MR-linac (Elekta AB, Stockholm, Sweden) relevant for dosimetric applications under clinical conditions. EPID images and ionization chamber (IC) measurements were used to study the effects of the magnetic field, the scatter generated in the MR housing reaching the EPID, and inhomogeneous attenuation from the MR housing. Dose linearity and dose rate dependencies were also determined. The magnetic field strength at EPID level did not exceed 10 mT, and dose linearity and dose rate dependencies proved to be comparable to that on a conventional linac. Profiles of fields, delivered with and without the magnetic field, were indistinguishable. The EPID center had an offset of 5.6 cm in the longitudinal direction, compared to the beam central axis, meaning that large fields in this direction will partially fall outside the detector area and not be suitable for verification. Beam attenuation by the MRI scanner and the table is gantry angle dependent, presenting a minimum attenuation of 67% relative to the 90° measurement. Repeatability, observed over two months, was within 0.5% (1 SD). In order to use the EPID for dosimetric applications in the MR-linac, challenges related to the EPID position, scatter from the MR housing, and the inhomogeneous, gantry angle-dependent attenuation of the beam will need to be solved.

  4. Characterization of the a-Si EPID in the unity MR-linac for dosimetric applications

    NASA Astrophysics Data System (ADS)

    Torres-Xirau, I.; Olaciregui-Ruiz, I.; Baldvinsson, G.; Mijnheer, B. J.; van der Heide, U. A.; Mans, A.

    2018-01-01

    Electronic portal imaging devices (EPIDs) are frequently used in external beam radiation therapy for dose verification purposes. The aim of this study was to investigate the dose-response characteristics of the EPID in the Unity MR-linac (Elekta AB, Stockholm, Sweden) relevant for dosimetric applications under clinical conditions. EPID images and ionization chamber (IC) measurements were used to study the effects of the magnetic field, the scatter generated in the MR housing reaching the EPID, and inhomogeneous attenuation from the MR housing. Dose linearity and dose rate dependencies were also determined. The magnetic field strength at EPID level did not exceed 10 mT, and dose linearity and dose rate dependencies proved to be comparable to that on a conventional linac. Profiles of fields, delivered with and without the magnetic field, were indistinguishable. The EPID center had an offset of 5.6 cm in the longitudinal direction, compared to the beam central axis, meaning that large fields in this direction will partially fall outside the detector area and not be suitable for verification. Beam attenuation by the MRI scanner and the table is gantry angle dependent, presenting a minimum attenuation of 67% relative to the 90° measurement. Repeatability, observed over two months, was within 0.5% (1 SD). In order to use the EPID for dosimetric applications in the MR-linac, challenges related to the EPID position, scatter from the MR housing, and the inhomogeneous, gantry angle-dependent attenuation of the beam will need to be solved.

  5. Fibrinolytic Activity and Dose-Dependent Effect of Incubating Human Blood Clots in Caffeic Acid Phenethyl Ester: In Vitro Assays

    PubMed Central

    Elnager, Abuzar; Hassan, Rosline; Idris, Zamzuri; Mustafa, Zulkifli; Wan-Arfah, Nadiah; Sulaiman, S. A.; Gan, Siew Hua; Abdullah, Wan Zaidah

    2015-01-01

    Background. Caffeic acid phenethyl ester (CAPE) has been reported to possess time-dependent fibrinolytic activity by in vitro assay. This study is aimed at investigating fibrinolytic dose-dependent activity of CAPE using in vitro assays. Methods. Standardized human whole blood (WB) clots were incubated in either blank controls or different concentrations of CAPE (3.75, 7.50, 15.00, 22.50, and 30.00 mM). After 3 hours, D-dimer (DD) levels and WB clot weights were measured for each concentration. Thromboelastography (TEG) parameters were recorded following CAPE incubation, and fibrin morphology was examined under a confocal microscope. Results. Overall, mean DD (μg/mL) levels were significantly different across samples incubated with different CAPE concentrations, and the median pre- and postincubation WB clot weights (grams) were significantly decreased for each CAPE concentration. Fibrin removal was observed microscopically and indicated dose-dependent effects. Based on the TEG test, the Ly30 fibrinolytic parameter was significantly different between samples incubated with two different CAPE concentrations (15.0 and 22.50 mM). The 50% effective dose (ED50) of CAPE (based on DD) was 1.99 mg/mL. Conclusions. This study suggests that CAPE possesses fibrinolytic activity following in vitro incubation and that it has dose-dependent activities. Therefore, further investigation into CAPE as a potential alternative thrombolytic agent should be conducted. PMID:25664321

  6. Dose Response of Endotoxin on Hepatocyte and Muscle Mitochondrial Respiration In Vitro

    PubMed Central

    Brandt, Sebastian; Porta, Francesca; Jakob, Stephan M.; Takala, Jukka; Djafarzadeh, Siamak

    2015-01-01

    Introduction. Results on mitochondrial dysfunction in sepsis are controversial. We aimed to assess effects of LPS at wide dose and time ranges on hepatocytes and isolated skeletal muscle mitochondria. Methods. Human hepatocellular carcinoma cells (HepG2) were exposed to placebo or LPS (0.1, 1, and 10 μg/mL) for 4, 8, 16, and 24 hours and primary human hepatocytes to 1 μg/mL LPS or placebo (4, 8, and 16 hours). Mitochondria from porcine skeletal muscle samples were exposed to increasing doses of LPS (0.1–100 μg/mg) for 2 and 4 hours. Respiration rates of intact and permeabilized cells and isolated mitochondria were measured by high-resolution respirometry. Results. In HepG2 cells, LPS reduced mitochondrial membrane potential and cellular ATP content but did not modify basal respiration. Stimulated complex II respiration was reduced time-dependently using 1 μg/mL LPS. In primary human hepatocytes, stimulated mitochondrial complex II respiration was reduced time-dependently using 1 μg/mL LPS. In isolated porcine skeletal muscle mitochondria, stimulated respiration decreased at high doses (50 and 100 μg/mL LPS). Conclusion. LPS reduced cellular ATP content of HepG2 cells, most likely as a result of the induced decrease in membrane potential. LPS decreased cellular and isolated mitochondrial respiration in a time-dependent, dose-dependent and complex-dependent manner. PMID:25649304

  7. Time-dependent radiation dose simulations during interplanetary space flights

    NASA Astrophysics Data System (ADS)

    Dobynde, Mikhail; Shprits, Yuri; Drozdov, Alexander; Hoffman, Jeffrey; Li, Ju

    2016-07-01

    Space radiation is one of the main concerns in planning long-term interplanetary human space missions. There are two main types of hazardous radiation - Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR). Their intensities and evolution depend on the solar activity. GCR activity is most enhanced during solar minimum, while the most intense SEPs usually occur during the solar maximum. SEPs are better shielded with thick shields, while GCR dose is less behind think shields. Time and thickness dependences of the intensity of these two components encourage looking for a time window of flight, when radiation intensity and dose of SEP and GCR would be minimized. In this study we combine state-of-the-art space environment models with GEANT4 simulations to determine the optimal shielding, geometry of the spacecraft, and launch time with respect to the phase of the solar cycle. The radiation environment was described by the time-dependent GCR model, and the SEP spectra that were measured during the period from 1990 to 2010. We included gamma rays, electrons, neutrons and 27 fully ionized elements from hydrogen to nickel. We calculated the astronaut's radiation doses during interplanetary flights using the Monte-Carlo code that accounts for the primary and the secondary radiation. We also performed sensitivity simulations for the assumed spacecraft size and thickness to find an optimal shielding. In conclusion, we present the dependences of the radiation dose as a function of launch date from 1990 to 2010, for flight durations of up to 3 years.

  8. Hydrocortisone Therapy in Catecholamine-Resistant Pediatric Septic Shock: A Pragmatic Analysis of Clinician Practice and Association With Outcomes.

    PubMed

    Nichols, Blake; Kubis, Sherri; Hewlett, Jennifer; Yehya, Nadir; Srinivasan, Vijay

    2017-09-01

    The 2012 Surviving Sepsis Campaign pediatric guidelines recommend stress dose hydrocortisone in children experiencing catecholamine-dependent septic shock with suspected or proven absolute adrenal insufficiency. We evaluated whether stress dose hydrocortisone therapy in children with catecholamine dependent septic shock correlated with random serum total cortisol levels and was associated with improved outcomes. Retrospective cohort study. Non-cardiac PICU. Critically ill children (1 mo to 18 yr) admitted between January 1, 2013, and December 31, 2013, with catecholamine dependent septic shock who had random serum total cortisol levels measured prior to potential stress dose hydrocortisone therapy. None. The cohort was dichotomized to random serum total cortisol less than 18 mcg/dL and greater than or equal to 18 mcg/dL. Associations of stress dose hydrocortisone with outcomes: PICU mortality, PICU and hospital length of stay, ventilator-free days, and vasopressor-free days were examined. Seventy children with catecholamine-dependent septic shock and measured random serum total cortisol levels were eligible (16% PICU mortality). Although 43% (30/70) had random serum total cortisol less than 18 μg/dL, 60% (42/70) received stress dose hydrocortisone. Children with random serum total cortisol less than 18 μg/dL had lower severity of illness and lower Vasopressor Inotrope Scores than those with random serum total cortisol greater than or equal to 18 μg/dL (all p < 0.05). Children with stress dose hydrocortisone had higher severity of illness and PICU mortality than those without stress dose hydrocortisone (all p < 0.05). Mean random serum total cortisol levels were similar in children with and without stress dose hydrocortisone (21.1 vs 18.7 μg/dL; p = 0.69). In children with random serum total cortisol less than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU and hospital length of stay and fewer ventilator-free days (all p < 0.05). In children with random serum total cortisol greater than 18 μg/dL, stress dose hydrocortisone was associated with greater PICU mortality and fewer ventilator-free days and vasopressor-free days (all p < 0.05). Stress dose hydrocortisone therapy in children with catecholamine-dependent septic shock correlated more with severity of illness than random serum total cortisol levels and was associated with worse outcomes, irrespective of random serum total cortisol levels.

  9. [Evaluation of an Experimental Production Wireless Dose Monitoring System for Radiation Exposure Management of Medical Staff].

    PubMed

    Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung

    2015-08-01

    Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.

  10. Characteristics of an OSLD in the diagnostic energy range.

    PubMed

    Al-Senan, Rani M; Hatab, Mustapha R

    2011-07-01

    Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R2 > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 degrees in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.

  11. Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography.

    PubMed

    Boere, Hub; Eijsvoogel, Nienke G; Sailer, Anna M; Wildberger, Joachim E; de Haan, Michiel W; Das, Marco; Jeukens, Cecile R L P N

    2018-05-01

    Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality. One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDI vol ) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDI vol versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDI vol values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale. The CTDI vol depended on patient size and scanner type (R 2 = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDI vol (R 2 = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better. We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.

  12. A study of normoxic polymer gel using monomer 2-hydroxyethyl methacrylate (HEMA)

    NASA Astrophysics Data System (ADS)

    Ishak, Siti Atiqah; Mustafa, Iskandar Shahrim; Rahman, Azhar Abdul; Moktar, Mohd; Min, Ung Ngie

    2015-04-01

    The aim of this study is to determine the sensitivity of HEMA-polymer gel mixture consist of monomer 2-hydroxyethyl methacrylate (HEMA) with different types of composition. Several composition of HEMA-polymer gel were fabricated and the gels were irradiated with radiation dose between 10 cGy to 100cGy by using x-ray machine and 100 cGy to 1400 cGy by using 6 MV photon beam energy of linear accelerator. The degree of polymerization was evaluated by using magnetic resonance imaging (MRI) with dependence of R2-dose response. Polymer gel consists of cross-linker, anti-oxidant Tetrakis(Hydroxymethyl)phosphonium chloride solution (THPC) and oxygen scavenger hydroquinone shows a stable sensitivity with highest dose dependency. Besides, the results shows the stage polymerization consist of induction, propagation, termination, and chain transfer were dependence with type of chemical mixture and radiation dose. Thus, normoxic HEMA-polymer gel with the different gel formulations can have a better dose resolution and an appropriate recipe must be selected to increase of the sensitivity required and the stability of the dosimeter.

  13. A study of normoxic polymer gel using monomer 2-hydroxyethyl methacrylate (HEMA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishak, Siti Atiqah; Mustafa, Iskandar Shahrim; Rahman, Azhar Abdul

    2015-04-24

    The aim of this study is to determine the sensitivity of HEMA-polymer gel mixture consist of monomer 2-hydroxyethyl methacrylate (HEMA) with different types of composition. Several composition of HEMA-polymer gel were fabricated and the gels were irradiated with radiation dose between 10 cGy to 100cGy by using x-ray machine and 100 cGy to 1400 cGy by using 6 MV photon beam energy of linear accelerator. The degree of polymerization was evaluated by using magnetic resonance imaging (MRI) with dependence of R2-dose response. Polymer gel consists of cross-linker, anti-oxidant Tetrakis(Hydroxymethyl)phosphonium chloride solution (THPC) and oxygen scavenger hydroquinone shows a stable sensitivitymore » with highest dose dependency. Besides, the results shows the stage polymerization consist of induction, propagation, termination, and chain transfer were dependence with type of chemical mixture and radiation dose. Thus, normoxic HEMA-polymer gel with the different gel formulations can have a better dose resolution and an appropriate recipe must be selected to increase of the sensitivity required and the stability of the dosimeter.« less

  14. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures.

    PubMed

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Oosaka, Hajime; Tosa, Tetsuo; Kadowaki, Ken

    2014-12-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. AN EVALUATION OF THE BASIC CHARACTERISTICS OF A PLASTIC SCINTILLATING FIBRE DETECTOR IN CT RADIATION FIELDS.

    PubMed

    Terasaki, Kento; Fujibuchi, Toshioh; Toyoda, Takatoshi; Yoshida, Yutaka; Akasaka, Tsutomu; Nohtomi, Akihiro; Morishita, Junji

    2016-12-01

    The ionisation chamber for computed tomography (CT) is an instrument that is most commonly used to measure the computed tomography dose index. However, it has been reported that the 10 cm effective detection length of the ionisation chamber is insufficient due to the extent of the dose distribution outside the chamber. The purpose of this study was to estimate the basic characteristics of a plastic scintillating fibre (PSF) detector with a long detection length of 50 cm in CT radiation fields. The authors investigated position dependence using diagnostic X-ray equipment and dependencies for energy, dose rate and slice thickness using an X-ray CT system. The PSF detector outputs piled up at a count rate of 10 000 counts ms -1 in dose rate dependence study. With calibration, this detector may be useful as a CT dosemeter with a long detection length except for the measurement at high dose rate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Dose-dependent effects of theta burst rTMS on cortical excitability and resting-state connectivity of the human motor system.

    PubMed

    Nettekoven, Charlotte; Volz, Lukas J; Kutscha, Martha; Pool, Eva-Maria; Rehme, Anne K; Eickhoff, Simon B; Fink, Gereon R; Grefkes, Christian

    2014-05-14

    Theta burst stimulation (TBS), a specific protocol of repetitive transcranial magnetic stimulation (rTMS), induces changes in cortical excitability that last beyond stimulation. TBS-induced aftereffects, however, vary between subjects, and the mechanisms underlying these aftereffects to date remain poorly understood. Therefore, the purpose of this study was to investigate whether increasing the number of pulses of intermittent TBS (iTBS) (1) increases cortical excitability as measured by motor-evoked potentials (MEPs) and (2) alters functional connectivity measured using resting-state fMRI, in a dose-dependent manner. Sixteen healthy, human subjects received three serially applied iTBS blocks of 600 pulses over the primary motor cortex (M1 stimulation) and the parieto-occipital vertex (sham stimulation) to test for dose-dependent iTBS effects on cortical excitability and functional connectivity (four sessions in total). iTBS over M1 increased MEP amplitudes compared with sham stimulation after each stimulation block. Although the increase in MEP amplitudes did not differ between the first and second block of M1 stimulation, we observed a significant increase after three blocks (1800 pulses). Furthermore, iTBS enhanced resting-state functional connectivity between the stimulated M1 and premotor regions in both hemispheres. Functional connectivity between M1 and ipsilateral dorsal premotor cortex further increased dose-dependently after 1800 pulses of iTBS over M1. However, no correlation between changes in MEP amplitudes and functional connectivity was detected. In summary, our data show that increasing the number of iTBS stimulation blocks results in dose-dependent effects at the local level (cortical excitability) as well as at a systems level (functional connectivity) with a dose-dependent enhancement of dorsal premotor cortex-M1 connectivity. Copyright © 2014 the authors 0270-6474/14/346849-11$15.00/0.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volotskova, O; Xu, A; Jozsef, G

    Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibratedmore » with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.« less

  18. Comparison of Caffeine and d-amphetamine in Cocaine-Dependent Subjects: Differential Outcomes on Subjective and Cardiovascular Effects, Reward Learning, and Salivary Paraxanthine.

    PubMed

    Lane, Scott D; Green, Charles E; Schmitz, Joy M; Rathnayaka, Nuvan; Fang, Wendy B; Ferré, Sergi; Moeller, F Gerard

    2014-01-01

    Due to indirect modulation of dopamine transmission, adenosine receptor antagonists may be useful in either treating cocaine use or improving disrupted cognitive-behavioral functions associated with chronic cocaine use. To compare and contrast the stimulant effects of adenosine antagonism to direct dopamine stimulation, we administered 150 mg and 300 mg caffeine, 20 mg amphetamine, and placebo to cocaine-dependent vs. healthy control subjects, matched on moderate caffeine use. Data were obtained on measures of cardiovascular effects, subjective drug effects (ARCI, VAS, DEQ), and a probabilistic reward-learning task sensitive to dopamine modulation. Levels of salivary caffeine and the primary caffeine metabolite paraxanthine were obtained on placebo and caffeine dosing days. Cardiovascular results revealed main effects of dose for diastolic blood pressure and heart rate; follow up tests showed that controls were most sensitive to 300 mg caffeine and 20 mg amphetamine; cocaine-dependent subjects were sensitive only to 300 mg caffeine. Subjective effects results revealed dose × time and dose × group interactions on the ARCI A, ARCI LSD, and VAS 'elated' scales; follow up tests did not show systematic differences between groups with regard to caffeine or d-amphetamine. Large between-group differences in salivary paraxanthine (but not salivary caffeine) levels were obtained under both caffeine doses. The cocaine-dependent group expressed significantly higher paraxanthine levels than controls under 150 mg and 3-4 fold greater levels under 300 mg at 90 min and 150 min post caffeine dose. However, these differences also covaried with cigarette smoking status (not balanced between groups), and nicotine smoking is known to alter caffeine/paraxanthine metabolism via cytochrome P450 enzymes. These preliminary data raise the possibility that adenosine antagonists may affect cocaine-dependent and non-dependent subjects differently. In conjunction with previous preclinical and human studies, the data suggest that adenosine modulating drugs may have value in the treatment of stimulant use disorders.

  19. Pharmacokinetics and Bioavailability of Inhaled Esketamine in Healthy Volunteers.

    PubMed

    Jonkman, Kelly; Duma, Andreas; Olofsen, Erik; Henthorn, Thomas; van Velzen, Monique; Mooren, René; Siebers, Liesbeth; van den Beukel, Jojanneke; Aarts, Leon; Niesters, Marieke; Dahan, Albert

    2017-10-01

    Esketamine is traditionally administered via intravenous or intramuscular routes. In this study we developed a pharmacokinetic model of inhalation of nebulized esketamine with special emphasis on pulmonary absorption and bioavailability. Three increasing doses of inhaled esketamine (dose escalation from 25 to 100 mg) were applied followed by a single intravenous dose (20 mg) in 19 healthy volunteers using a nebulizer system and arterial concentrations of esketamine and esnorketamine were obtained. A multicompartmental pharmacokinetic model was developed using population nonlinear mixed-effects analyses. The pharmacokinetic model consisted of three esketamine, two esnorketamine disposition and three metabolism compartments. The inhalation data were best described by adding two absorption pathways, an immediate and a slower pathway, with rate constant 0.05 ± 0.01 min (median ± SE of the estimate). The amount of esketamine inhaled was reduced due to dose-independent and dose-dependent reduced bioavailability. The former was 70% ± 5%, and the latter was described by a sigmoid EMAX model characterized by the plasma concentration at which absorption was impaired by 50% (406 ± 46 ng/ml). Over the concentration range tested, up to 50% of inhaled esketamine is lost due to the reduced dose-independent and dose-dependent bioavailability. We successfully modeled the inhalation of nebulized esketamine in healthy volunteers. Nebulized esketamine is inhaled with a substantial reduction in bioavailability. Although the reduction in dose-independent bioavailability is best explained by retention of drug and particle exhalation, the reduction in dose-dependent bioavailability is probably due to sedation-related loss of drug into the air.

  20. Effects of irradiation source and dose level on quality characteristics of processed meat products

    NASA Astrophysics Data System (ADS)

    Ham, Youn-Kyung; Kim, Hyun-Wook; Hwang, Ko-Eun; Song, Dong-Heon; Kim, Yong-Jae; Choi, Yun-Sang; Song, Beom-Seok; Park, Jong-Heum; Kim, Cheon-Jei

    2017-01-01

    The effect of irradiation source (gamma-ray, electron-beam, and X-ray) and dose levels on the physicochemical, organoleptic and microbial properties of cooked beef patties and pork sausages was studied, during 10 days of storage at 30±1 °C. The processed meat products were irradiated at 0, 2.5, 5, 7.5, and 10 kGy by three different irradiation sources. The pH of cooked beef patties and pork sausages was unaffected by irradiation sources or their doses. The redness of beef patties linearly decreased with increasing dose level (P<0.05), obviously by e-beam irradiation compared to gamma-ray and X-ray (P<0.05). The redness of pork sausages was increased by gamma-ray irradiation, whereas it decreased by e-beam irradiation depending on absorbed dose level. No significant changes in overall acceptability were observed for pork sausages regardless of irradiation source (P>0.05), while gamma-ray irradiated beef patties showed significantly decreased overall acceptability in a dose-dependent manner (P<0.05). Lipid oxidation of samples was accelerated by irradiation depending on irradiation sources and dose levels during storage at 30 °C. E-beam reduced total aerobic bacteria of beef patties more effectively, while gamma-ray considerably decreased microbes in pork sausages as irradiation dose increased. The results of this study indicate that quality attributes of meat products, in particular color, lipid oxidation, and microbial properties are significantly influenced by the irradiation sources.

  1. Dose-Dependent Effect of Statin Pretreatment on Preventing the Periprocedural Complications of Carotid Artery Stenting.

    PubMed

    Hong, Jeong-Ho; Sohn, Sung-Il; Kwak, Jaehyuk; Yoo, Joonsang; Chang, Hyuk Won; Kwon, O-Ki; Jung, Cheolkyu; Chung, Inyoung; Bae, Hee-Joon; Lee, Ji Sung; Han, Moon-Ku

    2017-07-01

    We investigated whether statin pretreatment can dose dependently reduce periprocedural complications in patients undergoing carotid artery stenting because of symptomatic carotid artery stenosis. We enrolled a consecutive series of 397 symptomatic carotid artery stenosis (≥50% stenosis on conventional angiography) treated with carotid artery stenting at 2 tertiary university hospitals over a decade. Definition of periprocedural complications included any stroke, myocardial infarction, and death within 1 month after or during the procedure. Statin pretreatment was divided into 3 categories according to the atorvastatin equivalent dose: none (n=158; 39.8%), standard dose (<40 mg of atorvastatin, n=155; 39.0%), and high dose (≥40 mg; n=84; 21.2%). A multivariable logistic regression analysis with the generalized estimating equation method was used to investigate independent factors in periprocedural complications. The patients' mean age was 68.7 years (81.6% men). The periprocedural complication rates across the 3 categories of statin use were 12.0%, 4.5%, and 1.2%. After adjustment, a change in the atorvastatin dose category was associated with reduction in the odds of periprocedural complications for each change in dose category (standard-dose statin: odds ratio, 0.24; 95% confidence interval, 0.07-0.81; high-dose statin: odds ratio, 0.11; 95% confidence interval, 0.01-0.96; P for trend=0.01). Administration of antiplatelet drugs was also an independent factor in periprocedural complications (OR, 0.18; 95% CI, 0.05-0.69). This study shows that statin pretreatment may reduce the incidence of periprocedural complications dose dependently in patients with symptomatic carotid artery stenting. © 2017 American Heart Association, Inc.

  2. Upper Bound Radiation Dose Assessment for Military Personnel at McMurdo Station, Antarctica, between 1962 and 1979 (2REV)

    DTIC Science & Technology

    2017-09-30

    veterans, their dependents , the Department of Veterans Affairs (VA), and the Naval Dosimetry Center regarding the VA radiogenic disease claims process. 15...nonexistent (HPS, 2010). Finally, to assist McMurdo Station veterans, their dependents , the VA, and the Naval Dosimetry Center, this report includes...24 h d−1 for 180 d Reasonable assumption 47 Parameter Value Rationale/Reference/Comment Dose coefficients Depends on organ 5-micrometer (µm

  3. Dose rate effects on array CCDs exposed by Co-60 γ rays induce saturation output degradation and annealing tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn; Chen, Wei; He, Baoping

    The experimental tests of dose rate and annealing effects on array charge-coupled devices (CCDs) are presented. The saturation output voltage (V{sub S}) versus the total dose at the dose rates of 0.01, 0.1, 1.0, 10.0 and 50 rad(Si)/s are compared. Annealing tests are performed to eliminate the time-dependent effects. The V{sub S} degradation levels depend on the dose rates. The V{sub S} degradation mechanism induced by dose rate and annealing effects is analyzed. The V{sub S} at 20 krad(Si) with the dose rate of 0.03 rad(Si)/s are supplemented to assure the degradation curves between the dose rates of 0.1 andmore » 0.01 rad(Si)/s. The CCDs are divided into two groups, with one group biased and the other unbiased during {sup 60}Co γ radiation. The V{sub S} degradation levels of the biased CCDs during radiation are more severe than that of the unbiased CCDs.« less

  4. Evaluation of characteristics of high-energy electron beams using N-isopropyl-acrylamide gel dosimeter

    NASA Astrophysics Data System (ADS)

    Shih, Tian-Yu; Yen, Tsung-Hsien; Liu, Yan-Lin; Luzhbin, Dmytro; Wu, Jay

    2017-11-01

    The advantage of electron beam radiotherapy is that the absorbed dose rapidly decreases with the increasing depth, which can prevent damage to deeper organs and tissues. Accurately evaluating the absorbed dose in the superficial tumor is imperative. This study assessed the characteristics of electron beams by using the N-isopropyl-acrylamide (n-NIPAM) gel dosimeter. The n-NIPAM gel was composed of 6% gelatin, 5% monomer, and 2.5% cross-linker with 5 mM tetrakis (hydroxymethyl) phosphonium chloride for deoxygenation. The gel was irradiated with 6-, 9-, and 12-MeV electron beams with dose rates of 100-600 MU/min, respectively. The energy dependence and dose rate dependence were assessed. The beam profiles and percentage depth doses were measured and compared with the results of the Gafchromic film and ionization chamber. The linearity of the n-NIPAM gel under 6-, 9-, and 12-MeV electrons was larger than 0.990 with 2% variation in sensitivity. The sensitivity of the gel under 100-600 MU/min showed 5% variations. The energy and dose rate dependence can be negligible. The beam profiles and percentage depth doses measured by the n-NIPAM gel matched well with the results of the ionization chamber and film. This study reveals the possibility of using the n-NIPAM gel dosimeter for electron beam measurements in clinical radiotherapy.

  5. Dual Effects of N,N-dimethylformamide on Cell Proliferation and Apoptosis in Breast Cancer

    PubMed Central

    Zhang, Jihong; Zhou, Daibing; Zhang, Lingyun; Lin, Qunbo; Ren, Weimin; Zhang, Jinguo; Nadeem, Lubna; Xu, Guoxiong

    2017-01-01

    N,N-dimethylformamide (DMF) has been widely used as an organic solvent in industries. DMF is a potential medication. However, the antitumorigenic role of DMF in breast cancer remains unclear. Here, we examined dose-dependent effects of DMF on proliferation and apoptosis in breast cancer MCF-7 and nontumorous MCF-12A cells. We found that DMF had a growth inhibitory effect in MCF-12A cells in a dose-dependent manner. By contrast, however, DMF had dual effects on cell proliferation and apoptosis in MCF-7 cells. DMF at a high dose (100 mM) significantly inhibited MCF-7 cell growth while at a low dose (1 mM) significantly stimulated MCF-7 cell growth (both P < .05). The inhibitory effect of DMF on cell proliferation was accompanied by the decrease of cyclin D1 and cyclin E1 protein expression, leading to the cell cycle arrest at the G0/G1 phase. Furthermore, a high-dose DMF significantly increased the number of early apoptotic cells by increasing cleaved caspase-9 and proapoptotic protein Bax expression and decreased the ratio of Bcl-xL/Bax (P < .01). Thus, our data demonstrated for the first time that DMF has dual effects on breast cancer cell behaviors depending upon its dose. Caution must be warranted in determining its effective dose for targeting breast cancer. PMID:29238273

  6. Accounting for neutron exposure in the Japanese atomic bomb survivors.

    PubMed

    Cullings, Harry M; Pierce, Donald A; Kellerer, Albrecht M

    2014-12-01

    The Japanese atomic bomb survivors that were directly exposed to both γ rays and neutrons have been followed by the Radiation Effects Research Foundation (RERF). The estimation of the γ-ray risks requires some adjustment for the greater biological effect of the neutrons per unit dose. Because the small neutron doses and the predominant γ-ray doses are highly correlated, the neutron relative biological effectiveness (RBE) cannot be reliably estimated from the survivors' data and information from radiobiology must be invoked. As data became available on neutron doses, RERF has used a constant neutron RBE value of 10, even though radiobiological studies indicate that the RBE values appear to have considerably larger values at low doses. The approximation RBE = 10 assumes that if the RBE is variable it takes roughly this value in the range of total dose most relevant for linear risk estimation, namely about 1 Gy. We consider some possible RBE functions to explain the correct use and the impact of a dose-dependent RBE. However, we do not advocate any particular choice or even that a variable RBE be employed. Rather we show that the assumed neutron RBE, within a wide range of choices, is far less important to the outcome of risk assessment of the RERF data than generally believed. Some of these misperceptions have been related to the consideration of variable RBE functions, and without due attention to the fact that in the case of the A-bomb survivors' data, the mixed field of neutrons and γ rays must be considered. Therefore, the RBE value of neutrons is much lower than the RBE in pure neutron fields that are used in radiobiological experiments. Thus, applying the pure neutron field RBE to the mixed-field A-bomb radiation can lead to an overestimation of the actual neutron RBE for moderate total dose levels of 1 Gy by a factor of more than four. While in a pure neutron exposure the RBE depends on the neutron dose, in the mixed field it depends on both components of exposure, and in particular, we show that in the RERF setting the RBE depends mainly on the accompanying γ-ray dose.

  7. Elevated mu-opioid receptor expression in the nucleus of the solitary tract accompanies attenuated withdrawal signs after chronic low dose naltrexone in opiate-dependent rats.

    PubMed

    Van Bockstaele, E J; Rudoy, C; Mannelli, P; Oropeza, V; Qian, Y

    2006-02-15

    We previously described a decrease in withdrawal behaviors in opiate-dependent rats that were chronically treated with very low doses of naltrexone in their drinking water. Attenuated expression of withdrawal behaviors correlated with decreased c-Fos expression and intracellular signal transduction elements [protein kinase A regulatory subunit II (PKA) and phosphorylated cAMP response element binding protein (pCREB)] in brainstem noradrenergic nuclei. In this study, to determine whether similar cellular changes occurred in forebrain nuclei associated with drug reward, expressions of PKA and pCREB were analyzed in the ventral tegmental area, frontal cortex, striatum, and amygdala of opiate-treated rats that received low doses of naltrexone in their drinking water. No significant difference in PKA or pCREB was detected in these regions following drug treatment. To examine further the cellular mechanisms in noradrenergic nuclei that could underlie attenuated withdrawal behaviors following low dose naltrexone administration, the nucleus of the solitary tract (NTS) and locus coeruleus (LC) were examined for opioid receptor (OR) protein expression. Results showed a significant increase in muOR expression in the NTS of morphine-dependent rats that received low doses of naltrexone in their drinking water, and increases in muOR expression were also found to be dose dependent. Protein expression of muOR in the LC and deltaOR in either brain region remained unchanged. In conclusion, our previously reported decreases in c-Fos and PKA expression in the NTS following pretreatment with low doses of naltrexone may be partially explained by a greater inhibition of NTS neurons resulting from increased muOR expression in this region.

  8. Dosimetric characterization of a single crystal diamond detector in X-ray beams for preclinical research.

    PubMed

    Kampfer, Severin; Cho, Nathan; Combs, Stephanie E; Wilkens, Jan J

    2018-05-29

    The aim of this study was to investigate a single crystal diamond detector, the microDiamond detector from PTW (PTW-Freiburg, Freiburg, Germany), concerning the particular requirements in the set-up and energy range used in small animal radiotherapy (RT) research (around 220kV). We tested it to find out the minimal required pre-irradiation dose, the dose linearity, dose rate dependency and the angular response as well as usability in the small animal radiation research platform, SARRP (Xstrahl Ltd., Camberley, UK). For a stable signal in the range of energies used in the study, we found a required pre-irradiation dose of 10Gy. The dose linearity and dose rate dependence measurements showed a very good performance of the microDiamond detector. Regarding the effect of angular dependency, the variation of the response signal is less than 0.5% within the first 15° of the polar angle. In the azimuthal angle, however, there are differences in detector response up to 20%, depending on the range of energies used in the study. In addition, we compared the detector to a radiosensitive film for a profile measurement of a 5×5mm 2 irradiation field. Both methods showed a good accordance with the field size, however, the film has a steeper dose gradient in the penumbra region but also a higher noise than the microDiamond detector. We demonstrated that the microDiamond detector is a useful measurement tool for small animal RT research due to its small size. Nevertheless, it seems to be very important to verify the response of the detector in the given set-up and energy range. Copyright © 2018. Published by Elsevier GmbH.

  9. Dose-dependent inhibition of gastric injury by hydrogen in alkaline electrolyzed drinking water.

    PubMed

    Xue, Jinling; Shang, Guodong; Tanaka, Yoshinori; Saihara, Yasuhiro; Hou, Lingyan; Velasquez, Natalia; Liu, Wenjun; Lu, Yun

    2014-03-03

    Hydrogen has been reported to relieve damage in many disease models, and is a potential additive in drinking water to provide protective effects for patients as several clinical studies revealed. However, the absence of a dose-response relationship in the application of hydrogen is puzzling. We attempted to identify the dose-response relationship of hydrogen in alkaline electrolyzed drinking water through the aspirin induced gastric injury model. In this study, hydrogen-rich alkaline water was obtained by adding H2 to electrolyzed water at one atmosphere pressure. After 2 weeks of drinking, we detected the gastric mucosal damage together with MPO, MDA and 8-OHdG in rat aspirin induced gastric injury model. Hydrogen-dose dependent inhibition was observed in stomach mucosal. Under pH 8.5, 0.07, 0.22 and 0.84 ppm hydrogen exhibited a high correlation with inhibitory effects showed by erosion area, MPO activity and MDA content in the stomach. Gastric histology also demonstrated the inhibition of damage by hydrogen-rich alkaline water. However, 8-OHdG level in serum did not have significant hydrogen-dose dependent effect. pH 9.5 showed higher but not significant inhibitory response compared with pH 8.5. Hydrogen is effective in relieving the gastric injury induced by aspirin-HCl, and the inhibitory effect is dose-dependent. The reason behind this may be that hydrogen-rich water directly interacted with the target tissue, while the hydrogen concentration in blood was buffered by liver glycogen, evoking a suppressed dose-response effect. Drinking hydrogen-rich water may protect healthy individuals from gastric damage caused by oxidative stress.

  10. SU-F-T-68: Characterizes of Microdetectors in Electron Beam Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, I; Andersen, A; Akino, Y

    Purpose: Electron beam dosimetry requires high resolution data due to finite range that can be accomplished with small volume detectors. The small-field used in advance technologies in photon beam has created a market for microdetectors, however characteristics are significantly variable in photon beams and relatively unknown in electron beam that is investigated in this study. Methods: Among nearly 2 dozen microdetectors that have been investigated in small fields of photon beam, two popular detectors (microDiamond 60019 (PTW)) and W1 plastic scintillator detector (Standard Imaging)) that are tissue equivalent and have very small sensitive volume are selected. Electron beams from Varianmore » linear accelerators were used to investigate dose linearity dose rate dependence, energy dependence, depth dose and profiles in a reference condition in a water phantom. For W1 that has its own Supermax electrometer point by point measurements were performed. For microDiamond, a PTW-scanning tank was used for both scanning and point dose measurements. Results: W1 detector showed excellent dose linearity (r{sup 2} =1.0) from 5–500 MU either with variation of dose rate or beam energy. Similar findings were also observed for microdiamond with r{sup 2}=1.0. Percent variations in dose/MU for W1 and microDiamond were 0.2–1.1% and 0.4–1.2%, respectively among dose rate and beam energy. This variation was random for microDiamond, whereas it decreased with beam energy and dose rate for W1. The depth dose and profiles were within ±1 mm for both detectors. Both detectors did not show any energy dependence in electron beams. Conclusion: Both microDiamond and W1 detectors provided superior characteristics of beam parameters in electron beam including dose, dose rate linearity and energy independence. Both can be used in electron beam except W1 require point by point measurements and microdiamond requires 1500 MU for initial quenching.« less

  11. Characteristics of mobile MOSFET dosimetry system for megavoltage photon beams

    PubMed Central

    Kumar, A. Sathish; Sharma, S. D.; Ravindran, B. Paul

    2014-01-01

    The characteristics of a mobile metal oxide semiconductor field effect transistor (mobile MOSFET) detector for standard bias were investigated for megavoltage photon beams. This study was performed with a brass alloy build-up cap for three energies namely Co-60, 6 and 15 MV photon beams. The MOSFETs were calibrated and the performance characteristics were analyzed with respect to dose rate dependence, energy dependence, field size dependence, linearity, build-up factor, and angular dependence for all the three energies. A linear dose-response curve was noted for Co-60, 6 MV, and 15 MV photons. The calibration factors were found to be 1.03, 1, and 0.79 cGy/mV for Co-60, 6 MV, and 15 MV photon energies, respectively. The calibration graph has been obtained to the dose up to 600 cGy, and the dose-response curve was found to be linear. The MOSFETs were found to be energy independent both for measurements performed at depth as well as on the surface with build-up. However, field size dependence was also analyzed for variable field sizes and found to be field size independent. Angular dependence was analyzed by keeping the MOSFET dosimeter in parallel and perpendicular orientation to the angle of incidence of the radiation with and without build-up on the surface of the phantom. The maximum variation for the three energies was found to be within ± 2% for the gantry angles 90° and 270°, the deviations without the build-up for the same gantry angles were found to be 6%, 25%, and 60%, respectively. The MOSFET response was found to be independent of dose rate for all three energies. The dosimetric characteristics of the MOSFET detector make it a suitable in vivo dosimeter for megavoltage photon beams. PMID:25190992

  12. Characteristics of mobile MOSFET dosimetry system for megavoltage photon beams.

    PubMed

    Kumar, A Sathish; Sharma, S D; Ravindran, B Paul

    2014-07-01

    The characteristics of a mobile metal oxide semiconductor field effect transistor (mobile MOSFET) detector for standard bias were investigated for megavoltage photon beams. This study was performed with a brass alloy build-up cap for three energies namely Co-60, 6 and 15 MV photon beams. The MOSFETs were calibrated and the performance characteristics were analyzed with respect to dose rate dependence, energy dependence, field size dependence, linearity, build-up factor, and angular dependence for all the three energies. A linear dose-response curve was noted for Co-60, 6 MV, and 15 MV photons. The calibration factors were found to be 1.03, 1, and 0.79 cGy/mV for Co-60, 6 MV, and 15 MV photon energies, respectively. The calibration graph has been obtained to the dose up to 600 cGy, and the dose-response curve was found to be linear. The MOSFETs were found to be energy independent both for measurements performed at depth as well as on the surface with build-up. However, field size dependence was also analyzed for variable field sizes and found to be field size independent. Angular dependence was analyzed by keeping the MOSFET dosimeter in parallel and perpendicular orientation to the angle of incidence of the radiation with and without build-up on the surface of the phantom. The maximum variation for the three energies was found to be within ± 2% for the gantry angles 90° and 270°, the deviations without the build-up for the same gantry angles were found to be 6%, 25%, and 60%, respectively. The MOSFET response was found to be independent of dose rate for all three energies. The dosimetric characteristics of the MOSFET detector make it a suitable in vivo dosimeter for megavoltage photon beams.

  13. Quantitative simulation of intracellular signaling cascades in a Virtual Liver: estimating dose dependent changes in hepatocellular proliferation and apoptosis

    EPA Science Inventory

    The US EPA Virtual Liver (v-Liver™) is developing an approach to predict dose-dependent hepatotoxicity as an in vivo tissue level response using in vitro data. The v-Liver accomplishes this using an in silico agent-based systems model that dynamically integrates environmental exp...

  14. Mouse and Human Models for Investigating Influences of Tau on Progression of Alzheimer’s Disease Following Traumatic Neuronal Injury

    DTIC Science & Technology

    2017-10-01

    bouts of mechanical loading amplified amyloid and tau phenotypes, suggesting a dependence of these Alzheimer’s associated outcomes to injury dose or...and tau phenotypes suggests a dose dependence of Ad-associated outcomes with the frequency and/or severity of injury. o What was the impact on

  15. The environmental chemical tributyltin chloride (TBT) shows both estrogenic and adipogenic activities in mice which might depend on the exposure dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penza, M.; Jeremic, M.; Marrazzo, E.

    2011-08-15

    Exposure during early development to chemicals with hormonal action may be associated with weight gain during adulthood because of altered body homeostasis. It is known that organotins affect adipose mass when exposure occurs during fetal development, although no knowledge of effects are available for exposures after birth. Here we show that the environmental organotin tributyltin chloride (TBT) exerts adipogenic action when peripubertal and sexually mature mice are exposed to the chemical. The duration and extent of these effects depend on the sex and on the dose of the compound, and the effects are relevant at doses close to the estimatedmore » human intake (0.5 {mu}g/kg). At higher doses (50-500 {mu}g/kg), TBT also activated estrogen receptors (ERs) in adipose cells in vitro and in vivo, based on results from acute and longitudinal studies in ERE/luciferase reporter mice. In 3T3-L1 cells (which have no ERs), transiently transfected with the ERE-dependent reporter plus or minus ER{alpha} or ER{beta}, TBT (in a dose range of 1-100 nM) directly targets each ER subtype in a receptor-specific manner through a direct mechanism mediated by ER{alpha} in undifferentiated preadipocytic cells and by ER{beta} in differentiating adipocytes. The ER antagonist ICI-182,780 inhibits this effect. In summary, the results of this work suggest that TBT is adipogenic at all ages and in both sexes and that it might be an ER activator in fat cells. These findings might help to resolve the apparent paradox of an adipogenic chemical being also an estrogen receptor activator by showing that the two apparently opposite actions are separated by the different doses to which the organism is exposed. - Research Highlights: > The environmental organotin tributyltin chloride shows dose-dependent estrogenic and adipogenic activities in mice. > The duration and extent of these effects depend on the sex and the dose of the compound. > The estrogenic and adipogenic effects of TBT occur at doses closed to the estimated human intake. > TBT activates the estrogen receptors (ER{alpha} and ER{beta}) in 3T3-L1 cells at nM concentrations.« less

  16. Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.

    PubMed

    Jursinic, Paul A

    2007-12-01

    Optically stimulated luminescent dosimeters, OSLDs, are plastic disks infused with aluminum oxide doped with carbon (Al2O3 : C). These disks are encased in a light-tight plastic holder. Crystals of Al2O3 : C when exposed to ionizing radiation store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. OSLDs used in this work were InLight/OSL Dot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). The following are dosimetric properties of the OSLD that were determined: After a single irradiation, repeated readings cause the signal to decrease by 0.05% per reading; the signal could be discharged by greater than 98% by illuminating them for more than 45 s with a 150 W tungsten-halogen light; after irradiation there was a transient signal that decayed with a 0.8 min halftime; after the transient signal decay the signal was stable for days; repeated irradiations and readings of an individual OSLD gave a signal with a coefficient of variation of 0.6%; the dose sensitivity of OSLDs from a batch of detectors has a coefficient of variation of 0.9%, response was linear with absorbed dose over a test range of 1-300 cGy; above 300 cGy a small supra-linear behavior occurs; there was no dose-per-pulse dependence over a 388-fold range; there was no dependence on radiation energy or mode for 6 and 15 MV x rays and 6-20 MeV electrons; for Ir-192 gamma rays OSLD had 6% higher sensitivity; the dose sensitivity was unchanged up to an accumulated dose of 20 Gy and thereafter decreased by 4% per 10 Gy of additional accumulated dose; dose sensitivity was not dependent on the angle of incidence of radiation; the OSLD in its light-tight case has an intrinsic buildup of 0.04 g/cm2; dose sensitivity of the OSLD was not dependent on temperature at the time of irradiation in the range of 10-40 degrees C. The clinical use of OSLDs for in vivo dosimetric measurements is shown to be feasible.

  17. Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jursinic, Paul A.

    2007-12-15

    Optically stimulated luminescent dosimeters, OSLDs, are plastic disks infused with aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C). These disks are encased in a light-tight plastic holder. Crystals of Al{sub 2}O{sub 3}:C when exposed to ionizing radiation store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. OSLDs used in this work were InLight/OSL Dot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). The following are dosimetricmore » properties of the OSLD that were determined: After a single irradiation, repeated readings cause the signal to decrease by 0.05% per reading; the signal could be discharged by greater than 98% by illuminating them for more than 45 s with a 150 W tungsten-halogen light; after irradiation there was a transient signal that decayed with a 0.8 min halftime; after the transient signal decay the signal was stable for days; repeated irradiations and readings of an individual OSLD gave a signal with a coefficient of variation of 0.6%; the dose sensitivity of OSLDs from a batch of detectors has a coefficient of variation of 0.9%, response was linear with absorbed dose over a test range of 1-300 cGy; above 300 cGy a small supra-linear behavior occurs; there was no dose-per-pulse dependence over a 388-fold range; there was no dependence on radiation energy or mode for 6 and 15 MV x rays and 6-20 MeV electrons; for Ir-192 gamma rays OSLD had 6% higher sensitivity; the dose sensitivity was unchanged up to an accumulated dose of 20 Gy and thereafter decreased by 4% per 10 Gy of additional accumulated dose; dose sensitivity was not dependent on the angle of incidence of radiation; the OSLD in its light-tight case has an intrinsic buildup of 0.04 g/cm{sup 2}; dose sensitivity of the OSLD was not dependent on temperature at the time of irradiation in the range of 10-40 deg. C. The clinical use of OSLDs for in vivo dosimetric measurements is shown to be feasible.« less

  18. HDL and CER-001 Inverse-Dose Dependent Inhibition of Atherosclerotic Plaque Formation in apoE-/- Mice: Evidence of ABCA1 Down-Regulation

    PubMed Central

    Tardy, Claudine; Goffinet, Marine; Boubekeur, Nadia; Cholez, Guy; Ackermann, Rose; Sy, Gavin; Keyserling, Constance; Lalwani, Narendra; Paolini, John F.; Dasseux, Jean-Louis; Barbaras, Ronald; Baron, Rudi

    2015-01-01

    Objective CER-001 is a novel engineered HDL-mimetic comprised of recombinant human apoA-I and charged phospholipids that was designed to mimic the beneficial properties of nascent pre-ß HDL. In this study, we have evaluated the dose-dependent regulation of ABCA1 expression in vitro and in vivo in the presence of CER-001 and native HDL (HDL3). Methods and Results CER-001 induced cholesterol efflux from J774 macrophages in a dose-dependent manner similar to natural HDL. A strong down-regulation of the ATP-binding cassette A1 (ABCA1) transporter mRNA (- 50%) as well as the ABCA1 membrane protein expression (- 50%) was observed at higher doses of CER-001 and HDL3 compared to non-lipidated apoA-I. In vivo, in an apoE-/- mouse “flow cessation model,” in which the left carotid artery was ligatured to induce local inflammation, the inhibition of atherosclerotic plaque burden progression in response to a dose-range of every-other-day CER-001 or HDL in the presence of a high-fat diet for two weeks was assessed. We observed a U-shaped dose-response curve: inhibition of the plaque total cholesterol content increased with increasing doses of CER-001 or HDL3 up to a maximum inhibition (- 51%) at 5 mg/kg; however, as the dose was increased above this threshold, a progressively less pronounced inhibition of progression was observed, reaching a complete absence of inhibition of progression at doses of 20 mg/kg and over. ABCA1 protein expression in the same atherosclerotic plaque was decreased by-45% and-68% at 50 mg/kg for CER-001 and HDL respectively. Conversely, a-12% and 0% decrease in ABCA1 protein expression was observed at the 5 mg/kg dose for CER-001 and HDL respectively. Conclusions These data demonstrate that high doses of HDL and CER-001 are less effective at slowing progression of atherosclerotic plaque in apoE-/- mice compared to lower doses, following a U-shaped dose-response curve. A potential mechanism for this phenomenon is supported by the observation that high doses of HDL and CER-001 induce a rapid and strong down-regulation of ABCA1 both in vitro and in vivo. In conclusion, maximally efficient HDL- or CER-001-mediated cholesterol removal from atherosclerotic plaque is achieved by maximizing macrophage-mediated efflux from the plaque while minimizing dose-dependent down-regulation of ABCA1 expression. These observations may help define the optimal dose of HDL mimetics for testing in clinical trials of atherosclerotic burden regression. PMID:26335690

  19. HDL and CER-001 Inverse-Dose Dependent Inhibition of Atherosclerotic Plaque Formation in apoE-/- Mice: Evidence of ABCA1 Down-Regulation.

    PubMed

    Tardy, Claudine; Goffinet, Marine; Boubekeur, Nadia; Cholez, Guy; Ackermann, Rose; Sy, Gavin; Keyserling, Constance; Lalwani, Narendra; Paolini, John F; Dasseux, Jean-Louis; Barbaras, Ronald; Baron, Rudi

    2015-01-01

    CER-001 is a novel engineered HDL-mimetic comprised of recombinant human apoA-I and charged phospholipids that was designed to mimic the beneficial properties of nascent pre-ß HDL. In this study, we have evaluated the dose-dependent regulation of ABCA1 expression in vitro and in vivo in the presence of CER-001 and native HDL (HDL3). CER-001 induced cholesterol efflux from J774 macrophages in a dose-dependent manner similar to natural HDL. A strong down-regulation of the ATP-binding cassette A1 (ABCA1) transporter mRNA (- 50%) as well as the ABCA1 membrane protein expression (- 50%) was observed at higher doses of CER-001 and HDL3 compared to non-lipidated apoA-I. In vivo, in an apoE-/- mouse "flow cessation model," in which the left carotid artery was ligatured to induce local inflammation, the inhibition of atherosclerotic plaque burden progression in response to a dose-range of every-other-day CER-001 or HDL in the presence of a high-fat diet for two weeks was assessed. We observed a U-shaped dose-response curve: inhibition of the plaque total cholesterol content increased with increasing doses of CER-001 or HDL3 up to a maximum inhibition (- 51%) at 5 mg/kg; however, as the dose was increased above this threshold, a progressively less pronounced inhibition of progression was observed, reaching a complete absence of inhibition of progression at doses of 20 mg/kg and over. ABCA1 protein expression in the same atherosclerotic plaque was decreased by-45% and-68% at 50 mg/kg for CER-001 and HDL respectively. Conversely, a-12% and 0% decrease in ABCA1 protein expression was observed at the 5 mg/kg dose for CER-001 and HDL respectively. These data demonstrate that high doses of HDL and CER-001 are less effective at slowing progression of atherosclerotic plaque in apoE-/- mice compared to lower doses, following a U-shaped dose-response curve. A potential mechanism for this phenomenon is supported by the observation that high doses of HDL and CER-001 induce a rapid and strong down-regulation of ABCA1 both in vitro and in vivo. In conclusion, maximally efficient HDL- or CER-001-mediated cholesterol removal from atherosclerotic plaque is achieved by maximizing macrophage-mediated efflux from the plaque while minimizing dose-dependent down-regulation of ABCA1 expression. These observations may help define the optimal dose of HDL mimetics for testing in clinical trials of atherosclerotic burden regression.

  20. Different effects of high- and low-dose phenobarbital on post-stroke seizure suppression and recovery in immature CD1 mice

    PubMed Central

    Markowitz, Geoffrey J.; Kadam, Shilpa D.; Smith, Dani R.; Johnston, Michael V.; Comi, Anne M.

    2011-01-01

    Neonatal stroke presents with seizures that are usually treated with phenobarbital. We hypothesized that anticonvulsants would attenuate ischemic injury, but that the dose-dependent effects of standard anticonvulsants would impact important age-dependent and injury-dependent consequences. In this study, ischemia induced by unilateral carotid ligation in postnatal day 12 (P12) CD1 mice was immediately followed by an i.p. dose of vehicle, low-dose or high-dose phenobarbital. Severity of acute behavioral seizures was scored. 5-bromo-2’-deoxyuridine (BrdU) was administered from P18-P20, behavioral testing performed, and mice perfused at P40. Atrophy quantification and counts of BrdU/NeuN-labeled cells in the dentate gyrus were performed. Blood phenobarbital concentrations were measured. 30 mg/kg phenobarbital reduced acute seizures and chronic brain injury, and restored normal weight gain and exploratory behavior. By comparison, 60 mg/kg was a less efficacious anticonvulsant, was not neuroprotective, did not restore normal weight gain, and impaired behavioral and cognitive recovery. Hippocampal neurogenesis was not different between treatment groups. These results suggest a protective effect of lower-dose phenobarbital, but a lack of this effect at higher concentrations after stroke in P12 mice. PMID:21481568

  1. Bupropion Dose-Dependently Reverses Nicotine Withdrawal Deficits in Contextual Fear Conditioning

    PubMed Central

    Portugal, George S.; Gould, Thomas J.

    2007-01-01

    Bupropion, a norepinephrine and dopamine reuptake inhibitor and nicotinic acetylcholine receptor antagonist, facilitates smoking cessation and reduces some symptoms of nicotine withdrawal. However, the effects of bupropion on nicotine withdrawal-associated deficits in learning remain unclear. The present study investigated whether bupropion has effects on contextual and cued fear conditioning following withdrawal from chronic nicotine or when administered alone. Bupropion was administered alone for a range of doses (2.5, 5, 10, 20 or 40 mg/kg), and dose-dependent impairments in contextual and cued fear conditioning were observed (20 or 40 mg/kg). Follow-up studies investigated if bupropion disrupted acquisition or expression of fear conditioning. Bupropion (40 mg/kg) administration on training day only produced deficits in contextual fear conditioning. Alternatively, bupropion (20 or 40 mg/kg) administration during testing dose-dependently produced deficits in contextual and cued fear conditioning. To test the effect of bupropion on nicotine withdrawal, mice were withdrawn from 12 days of chronic nicotine (6.3 mg/kg/day) or saline treatment. Withdrawal from chronic nicotine disrupted contextual fear conditioning; however, 5 mg/kg bupropion reversed this deficit. Overall, these results indicate that a low dose of bupropion can reverse nicotine withdrawal deficits in contextual fear conditioning, but that high doses of bupropion produce deficits in fear conditioning. PMID:17868796

  2. Relationships between patient size, dose and image noise under automatic tube current modulation systems.

    PubMed

    Sookpeng, S; Martin, C J; Gentle, D J; Lopez-Gonzalez, M R

    2014-03-01

    Automatic tube current modulation (ATCM) systems are now used for the majority of CT scans. The principles of ATCM operation are different in CT scanners from different manufacturers. Toshiba and GE scanners base the current modulation on a target noise setting, while Philips and Siemens scanners use reference image and reference mAs concepts respectively. Knowledge of the relationships between patient size, dose and image noise are important for CT patient dose optimisation. In this study, the CT patient doses were surveyed for 14 CT scanners from four different CT scanner manufacturers. The patient cross sectional area, the tube current modulation and the image noise from the CT images were analysed using in-house software. The Toshiba and GE scanner results showed that noise levels are relatively constant but tube currents are dependent on patient size. As a result of this there is a wide range in tube current values across different patient sizes, and doses for large patients are significantly higher in these scanners. In contrast, in the Philips and Siemens scanners, tube currents are less dependent on patient size, the range in tube current is narrower, and the doses for larger patients are not as high. Image noise is more dependent on the patient size.

  3. ¹H NMR-based metabolic profiling of naproxen-induced toxicity in rats.

    PubMed

    Jung, Jeeyoun; Park, Minhwa; Park, Hye Jin; Shim, Sun Bo; Cho, Yang Ha; Kim, Jinho; Lee, Ho-Sub; Ryu, Do Hyun; Choi, Donwoong; Hwang, Geum-Sook

    2011-01-15

    The dose-dependent perturbations in urinary metabolite concentrations caused by naproxen toxicity were investigated using ¹H NMR spectroscopy coupled with multivariate statistical analysis. Histopathologic evaluation of naproxen-induced acute gastrointestinal damage in rats demonstrated a significant dose-dependent effect. Furthermore, principal component analysis (PCA) of ¹H NMR from rat urine revealed a dose-dependent metabolic shift between the vehicle-treated control rats and rats treated with low-dose (10 mg/kg body weight), moderate-dose (50 mg/kg), and high-dose (100 mg/kg) naproxen, coinciding with their gastric damage scores after naproxen administration. The resultant metabolic profiles demonstrate that the naproxen-induced gastric damage exhibited energy metabolism perturbations that elevated their urinary levels of citrate, cis-aconitate, creatine, and creatine phosphate. In addition, naproxen administration decreased choline level and increased betaine level, indicating that it depleted the main protective constituent of the gastric mucosa. Moreover, naproxen stimulated the decomposition of tryptophan into kynurenate, which inhibits fibroblast growth factor-1 and delays ulcer healing. These findings demonstrate that ¹H NMR-based urinary metabolic profiling can facilitate noninvasive and rapid diagnosis of drug side effects and is suitable for elucidating possible biological pathways perturbed by drug toxicity. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. Protective role of Delphinium denudatum (Jadwar) against morphine induced tolerance and dependence in mice.

    PubMed

    Zafar, S; Ahmad, M A; Siddiqui, T A

    2001-11-01

    Chronic treatment with Delphinium denudatum (Dd) (Jadwar) (family: Ranunculaceae, 200-1600 mg/kg) suppressed morphine withdrawal jumps in a dose-dependent manner, a sign of the development of dependence to opiate as assessed by naloxone (2 mg/kg) precipitation withdrawal on day 10 of testing in mice. Repeated administration of Dd (200-1600 mg/kg) for 9 days attenuated the development of tolerance to the analgesic effect of morphine (10 mg/kg), also produces significant change in tail-flick latency from the saline pretreated group in a dose-dependent manner.

  5. Fast in-database cross-matching of high-cadence, high-density source lists with an up-to-date sky model

    NASA Astrophysics Data System (ADS)

    Scheers, B.; Bloemen, S.; Mühleisen, H.; Schellart, P.; van Elteren, A.; Kersten, M.; Groot, P. J.

    2018-04-01

    Coming high-cadence wide-field optical telescopes will image hundreds of thousands of sources per minute. Besides inspecting the near real-time data streams for transient and variability events, the accumulated data archive is a wealthy laboratory for making complementary scientific discoveries. The goal of this work is to optimise column-oriented database techniques to enable the construction of a full-source and light-curve database for large-scale surveys, that is accessible by the astronomical community. We adopted LOFAR's Transients Pipeline as the baseline and modified it to enable the processing of optical images that have much higher source densities. The pipeline adds new source lists to the archive database, while cross-matching them with the known cataloguedsources in order to build a full light-curve archive. We investigated several techniques of indexing and partitioning the largest tables, allowing for faster positional source look-ups in the cross matching algorithms. We monitored all query run times in long-term pipeline runs where we processed a subset of IPHAS data that have image source density peaks over 170,000 per field of view (500,000 deg-2). Our analysis demonstrates that horizontal table partitions of declination widths of one-degree control the query run times. Usage of an index strategy where the partitions are densely sorted according to source declination yields another improvement. Most queries run in sublinear time and a few (< 20%) run in linear time, because of dependencies on input source-list and result-set size. We observed that for this logical database partitioning schema the limiting cadence the pipeline achieved with processing IPHAS data is 25 s.

  6. Effect of ambient oxygen on the photoluminescence of sol-gel-derived nanocrystalline ZrO2:Eu,Nb

    NASA Astrophysics Data System (ADS)

    Puust, Laurits; Kiisk, Valter; Eltermann, Marko; Mändar, Hugo; Saar, Rando; Lange, Sven; Sildos, Ilmo; Dolgov, Leonid; Matisen, Leonard; Jaaniso, Raivo

    2017-06-01

    The development of inorganic nanophosphors is an active research field due to many applications, including optical gas sensing materials. We found a systematic dependence of the photoluminescence (PL) of europium (Eu3+) impurity ions in zirconia (ZrO2) nanocrystals on the ambient oxygen concentration in a O2/N2 mixture at normal pressure. Europium-doped ZrO2 powders were synthesized via a sol-gel route. Heat-treatment at 1200 °C resulted in a well-developed monoclinic phase (XRD crystallite size of ~50 nm) and an intense PL of Eu3+ ions residing in the dominant phase (Eu3+ was excited directly at 395 or 464 nm). Co-doping with niobium resulted in a narrowing of the PL emission lines. Only Nb5+ was detected by XPS and is believed to charge-compensate Eu3+ activators throughout the material leading to a more regular crystal lattice. At room temperature, the exposure to oxygen suppressed the Eu3+ fluorescence, whereas, at elevated temperatures (300 °C), the effect was reversed. At 300 °C and under a focused continuous laser beam, a substantial PL response (>50%) was achieved when switching 100% of N2 for 100% of O2. PL decay kinetics clearly showed that at 300 °C fluorescence quenching centers were induced within the material by oxygen desorption. The relatively fast (<5 min) and sub-linear PL response to the changes of oxygen concentration shows that ZrO2:Eu,Nb is a promising PL-based oxygen sensing material over a wide-range of oxygen pressures.

  7. Stimulation of body weight increase and epiphyseal cartilage growth by insulin like growth factor

    NASA Technical Reports Server (NTRS)

    Ellis, S.

    1981-01-01

    The ability of insulin-like growth factor (IGF) to induce growth in hypophysectomized immature rats was tested by continuous infusion of the partially purified factor at daily doses of 6, 21, and 46 mU for an 8-day period. A dose-dependent growth of the proximal epiphyseal cartilage of the tibia and an associated stimulation of the primary spongiosa were produced by these amounts of IGF. The two highest doses of IGF also resulted in dose-dependent increases of body weight. Gel permeation of the sera at neutrality showed that the large-molecular-weight IGF binding protein was not induced by the infusion of IGF, whereas it ws generated in the sera of hypophysectomized rats that were infused with daily doses of 86 mU of human growth hormone.

  8. [Dose-Response Dependences for Frequency of RET/PTC Gene Rearrangements in Papillary Thyroid Carcinoma after Irradiation. Simple Pooling Analysis of Molecular Epidemiological Data].

    PubMed

    Koterov, A N; Ushenkova, L N; Biryukov, A P

    2016-01-01

    On the basis of all possible publications on the theme included in the previously formed base of sources on molecular epidemiology of RET/PTC rearrangements in thyroid papillary carcinoma a pooled analysis ("simple pooling data") on determination of the dose-effect dependences for RET/PTC frequency in radiogenic carcinomas of various irradiated groups was performed. (They are groups subjected to radiotherapeutic exposure, residents near the Chernobyl nuclear power plant (CNPP) and victims of nuclear bombing). The tendency to Pearson linear correlation (r = 0.746; p = 0.148) between the frequency of RET/PTC and the estimated dose on thyroid in the regions affected by the CNPP accident was revealed. But this tendency was recognized to be random owing to abnormally low values of the indicator for the most contaminated Gomel region. The method tentatively called "case-control" showed reliable differences in thyroid dose values for carcinomas with RET/PTC and without those. The versatility of changes was found: the lack of RET/PTC for radiotherapeutic impacts was associated with higher doses, whereas in case of the CNPP accident and for nuclear bombing victims it was the opposite. Probably, in the first case the "cellular cleaning" phenomenon after exposure to very high doses took place. Search of direct Pearson correlations between average/median thyroid doses on groups and RET/PTC frequency in carcinomas of these groups showed a high reliability for the dose-effect dependences- at the continuous dose scale (for RET/PTC in total and RET/PTC1 respectively: r = 0.830; p = 0.002 and r = 0.906; p = 0.0003); while there was no significant correlation received for RET/PTC3. When using the weighting least square regression analysis (proceeding from the number of carcinomas in samples), the specified regularities remained. Attempts to influence the strength of correlation by exception ofthe data of all the samples connected with the accident on the CNPP did not significantly reduce the strength of associations for RET/PTC in total. On the basis of ordinal scale doses (background, "low" (0.1 Gy), "middle" (0.1-1 Gy) and "large" (1-10 Gy) dose) also found was a significant correlation (Spearman) with the dose for the frequency RET/PTC in total (r = 0.736; p = 0.0098), but for certain types of rearrangements the results were reverse to the previous analysis (the effect was significant only for the RET/PTC3: r = 0.731; p = 0.024). The linear dose-response trends of the Cochrane-Armitage-test for the frequency of RET/PTC in total, RET/PTC1 and RET/PTC3 depending on the dose to the thyroid in the ordinal scale were registered (p, respectively: < 0.0001 < 0.0001 and 0.007). Thus; after more than 20 years of the molecular and epidemiological research of RET/PTC in thyroid radiogenic carcinomas the comprehensive evidence of the dose-effect dependence existence indicating a real relationship between the studied parameters and a radiation factor was obtained for the first time.

  9. Dose-response characteristics of an amorphous silicon EPID.

    PubMed

    Winkler, Peter; Hefner, Alfred; Georg, Dietmar

    2005-10-01

    Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetric properties of an amorphous silicon EPID (Elekta IVIEWGT) with respect to three photon beam qualities: 6, 10, and 25 MV. The EPID showed an excellent temporal stability on short term as well as on long term scales. The stability throughout the day was strongly influenced by warming up, which took several hours and affected EPID response by 2.5%. Ghosting effects increased the sensitivity of the EPID. They became more pronounced with decreasing time intervals between two exposures as well as with increasing dose. Due to ghosting, changes in pixel sensitivity amounted up to 16% (locally) for the 25 MV photon beam. It was observed that the response characteristics of our EPID depended on dose as well as on dose rate. Doubling the dose rate increased the EPID sensitivity by 1.5%. This behavior was successfully attributed to a dose per frame effect, i.e., a nonlinear relationship between the EPID signal and the dose which was delivered to the panel between two successive readouts. The sensitivity was found to vary up to 10% in the range of 1 to 1000 monitor units. This variation was governed by two independent effects. For low doses, the EPID signal was reduced due to the linac's changing dose rate during startup. Furthermore, the detector reading was influenced by intrabeam variations of EPID sensitivity, namely, an increase of detector response during uniform exposure. For the beam qualities which were used, the response characteristics of the EPID did not depend on energy. Differences in relative dose-response curves resulted from energy dependent temporal output characteristics of the accelerator. If ghosting is prevented from affecting the results and all dose-response effects are properly corrected for, the EPID signal becomes independent of dose rate, dose, and exposure time.

  10. Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams

    NASA Astrophysics Data System (ADS)

    Moignier, Cyril; Tromson, Dominique; de Marzi, Ludovic; Marsolat, Fanny; García Hernández, Juan Carlos; Agelou, Mathieu; Pomorski, Michal; Woo, Romuald; Bourbotte, Jean-Michel; Moignau, Fabien; Lazaro, Delphine; Mazal, Alejandro

    2017-07-01

    The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min-1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate dependence.

  11. Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams.

    PubMed

    Moignier, Cyril; Tromson, Dominique; de Marzi, Ludovic; Marsolat, Fanny; García Hernández, Juan Carlos; Agelou, Mathieu; Pomorski, Michal; Woo, Romuald; Bourbotte, Jean-Michel; Moignau, Fabien; Lazaro, Delphine; Mazal, Alejandro

    2017-07-07

    The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV ) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min -1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate dependence.

  12. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter.

    PubMed

    Crescenti, Remo A; Bamber, Jeffrey C; Partridge, Mike; Bush, Nigel L; Webb, Steve

    2007-11-21

    Research on polymer-gel dosimetry has been driven by the need for three-dimensional dosimetry, and because alternative dosimeters are unsatisfactory or too slow for that task. Magnetic resonance tomography is currently the most well-developed technique for determining radiation-induced changes in polymer structure, but quick low-cost alternatives remain of significant interest. In previous work, ultrasound attenuation and speed of sound were found to change as a function of absorbed radiation dose in polymer-gel dosimeters, although the investigations were restricted to one ultrasound frequency. Here, the ultrasound attenuation coefficient mu in one polymer gel (MAGIC) was investigated as a function of radiation dose D and as a function of ultrasonic frequency f in a frequency range relevant for imaging dose distributions. The nonlinearity of the frequency dependence was characterized, fitting a power-law model mu = af(b); the fitting parameters were examined for potential use as additional dose readout parameters. In the observed relationship between the attenuation coefficient and dose, the slopes in a quasi-linear dose range from 0 to 30 Gy were found to vary with the gel batch but lie between 0.0222 and 0.0348 dB cm(-1) Gy(-1) at 2.3 MHz, between 0.0447 and 0.0608 dB cm(-1) Gy(-1) at 4.1 MHz and between 0.0663 and 0.0880 dB cm(-1) Gy(-1) at 6.0 MHz. The mean standard deviation of the slope for all samples and frequencies was 15.8%. The slope was greater at higher frequencies, but so were the intra-batch fluctuations and intra-sample standard deviations. Further investigations are required to overcome the observed variability, which was largely associated with the sample preparation technique, before it can be determined whether any frequency is superior to others in terms of accuracy and precision in dose determination. Nevertheless, lower frequencies will allow measurements through larger samples. The fit parameter a of the frequency dependence, describing the attenuation coefficient at 1 MHz, was found to be dose dependent, which is consistent with our expectations, as polymerization is known to be associated with increased absorption of ultrasound. No significant dose dependence was found for the fit parameter b, which describes the nonlinearity with frequency. This is consistent with the increased absorption being due to the introduction of new relaxation processes with characteristic frequencies similar to those of existing processes. The data presented here will help with optimizing the design of future 3D dose-imaging systems using ultrasound methods.

  13. Different dose rate-dependent responses of human melanoma cells and fibroblasts to low dose fast neutrons.

    PubMed

    Dionet, Claude; Müller-Barthélémy, Melanie; Marceau, Geoffroy; Denis, Jean-Marc; Averbeck, Dietrich; Gueulette, John; Sapin, Vincent; Pereira, Bruno; Tchirkov, Andrei; Chautard, Emmanuel; Verrelle, Pierre

    2016-09-01

    To analyze the dose rate influence in hyper-radiosensitivity (HRS) of human melanoma cells to very low doses of fast neutrons and to compare to the behaviour of normal human skin fibroblasts. We explored different neutron dose rates as well as possible implication of DNA double-strand breaks (DSB), apoptosis, and energy-provider adenosine-triphosphate (ATP) levels during HRS. HRS in melanoma cells appears only at a very low dose rate (VLDR), while a high dose rate (HDR) induces an initial cell-radioresistance (ICRR). HRS does not seem to be due either to DSB or to apoptosis. Both phenomena (HRS and ICRR) appear to be related to ATP availability for triggering cell repair. Fibroblast survival after neutron irradiation is also dose rate-dependent but without HRS. Melanoma cells or fibroblasts exert their own survival behaviour at very low doses of neutrons, suggesting that in some cases there is a differential between cancer and normal cells radiation responses. Only the survival of fibroblasts at HDR fits the linear no-threshold model. This new insight into human cell responses to very low doses of neutrons, concerns natural radiations, surroundings of accelerators, proton-therapy devices, flights at high altitude. Furthermore, ATP inhibitors could increase HRS during high-linear energy transfer (high-LET) irradiation.

  14. Long-Term Dose-Dependent Agalsidase Effects on Kidney Histology in Fabry Disease.

    PubMed

    Skrunes, Rannveig; Tøndel, Camilla; Leh, Sabine; Larsen, Kristin Kampevold; Houge, Gunnar; Davidsen, Einar Skulstad; Hollak, Carla; van Kuilenburg, André B P; Vaz, Frédéric M; Svarstad, Einar

    2017-09-07

    Dose-dependent clearing of podocyte globotriaosylceramide has previously been shown in patients with classic Fabry disease treated with enzyme replacement. Our study evaluates the dose-dependent effects of agalsidase therapy in serial kidney biopsies of patients treated for up to 14 years. Twenty patients with classic Fabry disease (12 men) started enzyme replacement therapy at a median age of 21 (range =7-62) years old. Agalsidase- α or - β was prescribed for a median of 9.4 (range =5-14) years. The lower fixed dose group received agalsidase 0.2 mg/kg every other week throughout the follow-up period. The higher dose group received a range of agalsidase doses (0.2-1.0 mg/kg every other week). Dose changes were made due to disease progression, suboptimal effect, or agalsidase- β shortage. Serial kidney biopsies were performed along with clinical assessment and biomarkers and scored according to recommendations from the International Study Group of Fabry Nephropathy. No statistical differences were found in baseline or final GFR or albuminuria. Kidney biopsies showed significant reduction of podocyte globotriaosylceramide in both the lower fixed dose group (-1.39 [SD=1.04]; P =0.004) and the higher dose group (-3.16 [SD=2.39]; P =0.002). Podocyte globotriaosylceramide (Gb3) reduction correlated with cumulative agalsidase dose ( r =0.69; P =0.001). Arterial/arteriolar intima Gb3 cleared significantly in the higher dose group, all seven patients with baseline intimal Gb3 cleared the intima, one patient gained intimal Gb3 inclusions ( P =0.03), and medial Gb3 did not change statistically in either group. Residual plasma globotriaosylsphingosine levels remained higher in the lower fixed dose group (20.1 nmol/L [SD=11.9]) compared with the higher dose group (10.4 nmol/L [SD=8.4]) and correlated with cumulative agalsidase dose in men ( r =0.71; P =0.01). Reduction of podocyte globotriaosylceramide was found in patients with classic Fabry disease treated with long-term agalsidase on different dosing regimens, correlating with cumulative dose. Limited clearing of arterial/arteriolar globotriaosylceramide raises concerns regarding long-term vascular effects of current therapy. Residual plasma globotriaosylsphingosine correlated with cumulative dose in men. Copyright © 2017 by the American Society of Nephrology.

  15. Intra-oral administration of rebamipide liquid prevents tongue injuries induced by X-ray irradiation in rats.

    PubMed

    Nakashima, Takako; Uematsu, Naoya; Sakurai, Kazushi

    2017-07-01

    Oral mucositis is a common and serious side effect in patients who undergo cytotoxic cancer therapies. The purpose of this study was to investigate the preventive effects of rebamipide on radiation-induced glossitis model in rats. Glossitis was induced by a single dose of 15 Gy of X-rays to the snouts of rats (day 0). A novel form of rebamipide liquid comprising its submicronized crystals was administered intra-orally. The preventive effect of rebamipide on tongue injuries was macroscopically evaluated on day 7 following irradiation. The pretreatment period, dosing frequency, and dose dependency of rebamipide were examined. Two percent rebamipide liquid, administered six times a day for 14 days from day -7 to day 6, significantly decreased the ulcer-like area. However, no significant effect was observed when rebamipide was given either from day -4 or from day -1. Four or six times daily, 2% rebamipide liquid significantly inhibited the ulcer-like injury area ratio, but not when given twice daily. Rebamipide liquid, 1, 2, and 4% six times daily significantly reduced the area ratios of total injury and ulcer-like injury in a dose-dependent manner. Gene expression and protein levels of proinflammatory cytokines and chemokines were dramatically elevated in the irradiated tongues of control rats on day 7 without rebamipide liquid treatment. They were dose-dependently and significantly suppressed in rebamipide-treated groups. Intra-oral administration of rebamipide liquid prevented oral mucositis dose-dependently accompanied by the suppression of inflammatory expression in the radiation-induced rats' glossitis model.

  16. Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA

    PubMed Central

    Chaswal, Vibha; Weldon, Michael; Gupta, Nilendu; Chakravarti, Arnab

    2014-01-01

    We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric‐modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle, and couch insertion. Scatter dose characterization, consistency and symmetry of response, and dosimetry accuracy evaluation for fixed aperture arcs and clinical VMAT patient plans were also investigated. All the evaluation tests were performed with the central plug inserted and the homogeneous PMMA density value. Results of gamma analysis demonstrated an overall agreement between ArcCHECK‐measured and TPS‐calculated reference doses. The diode based field size dependency was found to be within 0.5% of the reference. The dose rate‐based dependency was well within 1% of the TPS reference, and the angular dependency was found to be ± 3% of the reference, as tested for BEV angles, for both beams. Dosimetry of fixed arcs, using both narrow and wide field widths, resulted in clinically acceptable global gamma passing rates on the 3%/3 mm level and 10% threshold. Dosimetry of narrow arcs showed an improvement over published literature. The clinical VMAT cases demonstrated high level of dosimetry accuracy in gamma passing rates. PACS numbers: 87.56.Fc, 87.55.kh, 87.55.Qr PMID:25207411

  17. Endothelial function across an oral contraceptive cycle in women using levonorgestrel and ethinyl estradiol.

    PubMed

    Torgrimson, Britta N; Meendering, Jessica R; Kaplan, Paul F; Minson, Christopher T

    2007-06-01

    Oral contraceptive pills (OCPs) are a popular contraception method. Currently, lower-dose ethinyl estradiol formulations are most commonly prescribed, although they have been linked to increased arterial vascular risk. The aim of this study was to investigate endothelial function in healthy young women using lower-dose ethinyl estradiol OCPs. We examined flow-mediated, endothelium-dependent and nitroglycerin-mediated, endothelium-independent vasodilation of the brachial artery, comparing two doses of ethinyl estradiol/levonorgestrel OCPs in 15 healthy young women on two study days: once during the active phase and once during the placebo phase of an OCP cycle. Group low dose (LD) (n=7) active pills contained 150 microg levonorgestrel/30 microg ethinyl estradiol versus Group very low dose (VLD) (n=8) with 100 microg levonorgestrel/20 microg ethinyl estradiol. Endothelium-dependent vasodilation was lower during the active phase in Group VLD (5.33 +/- 1.77% vs. 7.23 +/- 2.60%; P=0.024). This phase difference was not observed in Group LD (8.00 +/- 0.970% vs. 7.61 +/- 1.07%; P=0.647). Endothelium-independent vasodilation did not differ between phases in either group. Finally, we measured endothelium-dependent vasodilation in two additional women who received 10 microg of unopposed ethinyl estradiol. Endothelium-dependent vasodilation was increased by unopposed ethinyl estradiol compared with the placebo phase (10.88 +/- 2.34% vs. 6.97 +/- 1.83%). These results suggest that levonorgestrel may antagonize the activity of ethinyl estradiol. Thus both the progestin type and estradiol dose need to be considered when assessing arterial vascular risk of OCP use in women.

  18. DNA adducts and liver DNA replication in rats during chronic exposure to N-nitrosodimethylamine (NDMA) and their relationships to the dose-dependence of NDMA hepatocarcinogenesis.

    PubMed

    Souliotis, Vassilis L; Henneman, John R; Reed, Carl D; Chhabra, Saranjit K; Diwan, Bhalchandra A; Anderson, Lucy M; Kyrtopoulos, Soterios A

    2002-03-20

    Exposure of rats to the hepatocarcinogen N-nitrosodimethylamine (NDMA) (0.2-2.64 ppm in the drinking water) for up to 180 days resulted in rapid accumulation of N7- and O6-methylguanine in liver and white blood cell DNA, maximum adduct levels being reached within 1-7 days, depending on the dose. The levels of both adducts remained constant up to treatment day 28, subsequently declining slowly to about 40% of maximal levels for the liver and 60% for white blood cells by day 180. In order to elucidate the role of DNA replication in NDMA hepatocarcinogenesis, changes in liver cell labeling index (LI) were also measured on treatment days 21, 120 and 180. Although the time- and dose-dependence of the observed effects were complex, a clear trend towards increased rates of hepatocyte LI, as indicated by BrdU incorporation, with increasing NDMA doses was evident, particularly above 1 ppm, a concentration above which NDMA hepatocarcinogenicity is known to increase sharply. In contrast, no increase in Kupffer cell DNA replication was found at any of the doses employed, in accordance with the low susceptibility of these cells to NDMA-induced carcinogenesis. No significant increase in the occurrence of necrotic or apoptotic cells was noted under the treatment conditions employed. These results suggest that, in addition to the accumulation of DNA damage, alterations in hepatocyte DNA replication during the chronic NDMA exposure may influence the dose-dependence of its carcinogenic efficacy.

  19. Testosterone influences spatial strategy preferences among adult male rats

    PubMed Central

    Spritzer, Mark D.; Fox, Elliott C.; Larsen, Gregory D.; Batson, Christopher G.; Wagner, Benjamin A.; Maher, Jack

    2013-01-01

    Males outperform females on some spatial tasks, and this may be partially due to the effects of sex steroids on spatial strategy preferences. Previous work with rodents indicates that low estradiol levels bias females toward a striatum-dependent response strategy, whereas high estradiol levels bias them toward a hippocampus-dependent place strategy. We tested whether testosterone influenced the strategy preferences in male rats. All subjects were castrated and assigned to one of three daily injection doses of testosterone (0.125, 0.250, or 0.500 mg/rat) or a control group that received daily injections of the drug vehicle. Three different maze protocols were used to determine rats’ strategy preferences. A low dose of testosterone (0.125 mg) biased males toward a motor-response strategy on a T-maze task. In a water maze task in which the platform itself could be used intermittently as a visual cue, a low testosterone dose (0.125 mg) caused a significant increase in the use of a cued-response strategy relative to control males. Results from this second experiment also indicated that males receiving a high dose of testosterone (0.500 mg) were biased toward a place strategy. A third experiment indicated that testosterone dose did not have a strong influence on the ability of rats to use a nearby visual cue (floating ball) in the water maze. For this experiment, all groups seemed to use a combination of place and cued-response strategies. Overall, the results indicate that the effects of testosterone on spatial strategy preference are dose dependent and task dependent. PMID:23597827

  20. Testosterone influences spatial strategy preferences among adult male rats.

    PubMed

    Spritzer, Mark D; Fox, Elliott C; Larsen, Gregory D; Batson, Christopher G; Wagner, Benjamin A; Maher, Jack

    2013-05-01

    Males outperform females on some spatial tasks, and this may be partially due to the effects of sex steroids on spatial strategy preferences. Previous work with rodents indicates that low estradiol levels bias females toward a striatum-dependent response strategy, whereas high estradiol levels bias them toward a hippocampus-dependent place strategy. We tested whether testosterone influenced the strategy preferences in male rats. All subjects were castrated and assigned to one of three daily injection doses of testosterone (0.125, 0.250, or 0.500 mg/rat) or a control group that received daily injections of the drug vehicle. Three different maze protocols were used to determine rats' strategy preferences. A low dose of testosterone (0.125 mg) biased males toward a motor-response strategy on a T-maze task. In a water maze task in which the platform itself could be used intermittently as a visual cue, a low testosterone dose (0.125 mg) caused a significant increase in the use of a cued-response strategy relative to control males. Results from this second experiment also indicated that males receiving a high dose of testosterone (0.500 mg) were biased toward a place strategy. A third experiment indicated that testosterone dose did not have a strong influence on the ability of rats to use a nearby visual cue (floating ball) in the water maze. For this experiment, all groups seemed to use a combination of place and cued-response strategies. Overall, the results indicate that the effects of testosterone on spatial strategy preference are dose dependent and task dependent. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Yohimbine Increases Opioid-Seeking Behavior in Heroin-Dependent, Buprenorphine-Maintained Individuals

    PubMed Central

    Greenwald, Mark K.; Lundahl, Leslie H.; Steinmiller, Caren L.

    2012-01-01

    Rationale In laboratory animals, the biological stressor yohimbine (α2-noradrenergic autoreceptor antagonist) promotes drug seeking. Human laboratory studies have demonstrated that psychological stressors can increase drug craving but not that stressors alter drug seeking. Objectives This clinical study tested whether yohimbine increases opioid seeking behavior. Methods Ten heroin-dependent, buprenorphine (8-mg/day) stabilized volunteers, sampled two doses of hydromorphone (12 and 24 mg IM in counterbalanced order, labeled Drug A [session 1] and Drug B [session 2]). During each of six later sessions (within-subject, double blind, randomized crossover design), volunteers could respond on a 12-trial choice progressive ratio task to earn units (1 or 2 mg) of the sampled hydromorphone dose (Drug A or B) vs. money ($2) following different oral yohimbine pretreatment doses (0, 16.2 and 32.4 mg). Results Behavioral economic demand intensity and peak responding (Omax) were significantly higher for hydromorphone 2-mg than 1-mg. Relative to placebo, yohimbine significantly increased hydromorphone demand inelasticity, more so for hydromorphone 1-mg units (Pmax = 909, 3647 and 3225 for placebo, 16.2 and 32.4 mg yohimbine doses, respectively) than hydromorphone 2-mg units (Pmax = 2656, 3193 and 3615, respectively). Yohimbine produced significant but clinically modest dose-dependent increases in blood pressure (systolic ≈15 and diastolic ≈10 mmHg) and opioid withdrawal symptoms, and decreased opioid agonist symptoms and elated mood. Conclusions These findings concur with preclinical data by demonstrating that yohimbine increases drug seeking; in this study, these effects occurred without clinically significant subjective distress or elevated craving, and partly depended on opioid unit dose. PMID:23161001

  2. A study on quantitative analysis of exposure dose caused by patient depending on time and distance in nuclear medicine examination

    NASA Astrophysics Data System (ADS)

    Kim, H. S.; Cho, J. H.; Shin, S. G.; Dong, K. R.; Chung, W. K.; Chung, J. E.

    2013-01-01

    This study evaluated possible actions that can help protect against and reduce radiation exposure by measuring the exposure dose for each type of isotope that is used frequently in nuclear medicine before performing numerical analysis of the effective half-life based on the measurement results. From July to August in 2010, the study targeted 10, 6 and 5 people who underwent an 18F-FDG (fludeoxyglucose) positron emission tomography (PET) scan, 99mTc-HDP bone scan, and 201Tl myocardial single-photon emission computed tomography (SPECT) scan, respectively, in the nuclear medicine department. After injecting the required medicine into the subjects, a survey meter was used to measure the dose depending on the distance from the heart and time elapsed. For the 18F-FDG PET scan, the dose decreased by approximately 66% at 90 min compared to that immediately after the injection and by 78% at a distance of 1 m compared to that at 0.3 m. In the 99mTc-HDP bone scan, the dose decreased by approximately 71% in 200 min compared to that immediately after the injection and by approximately 78% at a distance of 1 m compared to that at 0.3 m. In the 201Tl myocardial SPECT scan, the dose decreased by approximately 30% in 250 min compared to that immediately after the injection and by approximately 55% at a distance of 1 m compared to that at 0.3 m. In conclusion, the dose decreases by a large margin depending on the distance and time. In conclusion, this study measured the exposure doses by isotopes, distance from the heart and exposure time, and found that the doses were reduced significantly according the distance and the time.

  3. Effects of multiple ascending doses of the glucagon receptor antagonist PF-06291874 in patients with type 2 diabetes mellitus.

    PubMed

    Kazierad, D J; Bergman, A; Tan, B; Erion, D M; Somayaji, V; Lee, D S; Rolph, T

    2016-08-01

    To assess the pharmacokinetics, pharmacodynamics, safety and tolerability of multiple ascending doses of the glucagon receptor antagonist PF-06291874 in patients with type 2 diabetes mellitus (T2DM). Patients were randomized to oral PF-06291874 or placebo on a background of either metformin (Part A, Cohorts 1-5: 5-150 mg once daily), or metformin and sulphonylurea (Part B, Cohorts 1-2: 15 or 30 mg once daily) for 14-28 days. A mixed-meal tolerance test (MMTT) was administered on days -1 (baseline), 14 and 28. Assessments were conducted with regard to pharmacokinetics, various pharmacodynamic variables, safety and tolerability. Circulating amino acid concentrations were also measured. PF-06291874 exposure was approximately dose-proportional with a half-life of ∼19.7-22.7 h. Day 14 fasting plasma glucose and mean daily glucose values were reduced from baseline in a dose-dependent manner, with placebo-corrected decreases of 34.3 and 42.4 mg/dl, respectively, at the 150 mg dose. After the MMTT, dose-dependent increases in glucagon and total glucagon-like peptide-1 (GLP-1) were observed, although no meaningful changes were noted in insulin, C-peptide or active GLP-1 levels. Small dose-dependent increases in LDL cholesterol were observed, along with reversible increases in serum aminotransferases that were largely within the laboratory reference range. An increase in circulating gluconeogenic amino acids was also observed on days 2 and 14. All dose levels of PF-06291874 were well tolerated. PF-06291874 was well tolerated, has a pharmacokinetic profile suitable for once-daily dosing, and results in reductions in glucose with minimal risk of hypoglycaemia. © 2016 John Wiley & Sons Ltd.

  4. Growth hormone therapy for children born small for gestational age: height gain is less dose dependent over the long term than over the short term.

    PubMed

    de Zegher, Francis; Hokken-Koelega, Anita

    2005-04-01

    Approximately 3% of children are born small for gestational age (SGA), and approximately 10% of SGA children maintain a small body size throughout childhood and often into adult life. Among short SGA children, growth hormone (GH) therapy increases short-term growth in a dose-dependent manner; experience with long-term therapy is limited. To delineate the dose dependency of long-term height gain among short SGA children receiving GH therapy. We performed an epianalysis of the first adult height data for SGA children (n = 28) enrolled in 3 randomized trials comparing the growth-promoting efficacy of 2 continuous GH regimens (33 or 67 microg/kg per day for approximately 10 years, starting at approximately 5 years of age); in addition, we performed a meta-analysis of the adult height results published previously and those presented here. Epianalysis outcomes (n = 28) suggested that adult height increased more with a higher-dose regimen than with a lower-dose regimen. In the meta-analysis (n = 82), the higher-dose regimen was found to elicit a long-term height gain superior to that achieved with the lower-dose regimen by a mean of 0.4 SD (approximately 1 inch). Children who were shorter at the start of therapy experienced more long-term height gain. These findings confirm GH therapy as an effective and safe approach to reduce the adult height deficit that short SGA children otherwise face. In addition, the first meta-analysis indicated that height gain is less dose dependent over the long term than over the short term, at least within the dose range explored to date. For SGA children whose stature is not extremely short, current data support the use of a GH dose of approximately 33 microg/kg per day from start to adult height, particularly if treatment starts at a young age; shorter children (for example, height below -3 SD) might benefit from an approach in which short-term catch-up growth is achieved with a higher dose (> or =50 microg/kg per day) and long-term growth to adult height is ensured with a GH dose of approximately 33 mug/kg per day. Because GH-induced accelerations of height and weight gain evolve in parallel, the dose tapering from > or =50 microg/kg to approximately 33 microg/kg can be accomplished by simply maintaining the absolute GH dose (in micrograms) while the child gains weight (in kilograms). With this algorithm, more growth-responsive children taper their GH dose down to approximately 33 microg/kg per day more quickly.

  5. Buprenorphine and a CRF1 antagonist block the acquisition of opiate withdrawal-induced conditioned place aversion in rats.

    PubMed

    Stinus, Luis; Cador, Martine; Zorrilla, Eric P; Koob, George F

    2005-01-01

    Conditioned place aversion in rats has face validity as a measure of the aversive stimulus effects of opiate withdrawal that reflects an important motivational component of opiate dependence. The purpose of the present study was to validate conditioned place aversion as sensitive to medications that will alleviate the aversive stimulus effects of opiate withdrawal in humans, and to extend this model to the exploration of the neuropharmacological basis of the motivational effects of opiate withdrawal. Male Sprague-Dawley rats were implanted with two subcutaneous morphine pellets and 5 days later began place conditioning training following subcutaneous administration of a low dose of naloxone. Animals were subjected to three pairings of a low dose of naloxone (15 microg/kg, s.c.) to one arm of a three-chambered place conditioning apparatus. Buprenorphine administered prior to each pairing dose-dependently blocked the place aversion produced by precipitated opiate withdrawal. A corticotropin-releasing factor-1 (CRF1) receptor antagonist (antalarmin) also reversed the place aversion produced by precipitated opiate withdrawal. Antalarmin did not produce a place preference or place aversion by itself in morphine-dependent rats. No effect was observed with pretreatment of the dopamine partial agonist terguride or the selective serotonin reuptake inhibitor fluoxetine. Also, chronic pretreatment with acamprosate (a glutamate receptor modulator used to prevent relapse in alcohol dependence) did not alter naloxone-induced place aversion. Buprenorphine by itself in dependent rats produced a mild place preference at low doses and a mild place aversion at higher doses. These results suggest that buprenorphine blocks the aversive stimulus effects of precipitated opiate withdrawal in rats and provides some validity for the use of place conditioning as a measure that is sensitive to potential opiate-dependence medications. In addition, these results suggest that CRF1 antagonists can block the aversive stimulus effects of opiate withdrawal and may be potential therapeutic targets for opiate dependence.

  6. Homogeneity of GAFCHROMIC EBT2 film among different lot numbers

    PubMed Central

    Takahashi, Yutaka; Tanaka, Atsushi; Hirayama, Takamitsu; Yamaguchi, Tsuyoshi; Katou, Hiroaki; Takahara, Keiko; Okamoto, Yoshiaki; Teshima, Teruki

    2012-01-01

    EBT2 film is widely used for quality assurance in radiation therapy. The purpose of this study was to investigate the homogeneity of EBT2 film among various lots, and the dose dependence of heterogeneity. EBT2 film was positioned in the center of a flatbed scanner and scanned in transmission mode at 75 dpi. Homogeneity was investigated by evaluating gray value and net optical density (netOD) with the red color channel. The dose dependence of heterogeneity in a single sheet from five lots was investigated at 0.5, 2, and 3 Gy. Maximum coefficient of variation as evaluated by netOD in a single film was 3.0% in one lot, but no higher than 0.5% in other lots. Dose dependence of heterogeneity was observed on evaluation by gray value but not on evaluation by netOD. These results suggest that EBT2 should be examined in each lot number before clinical use, and that the dose calibration curve should be constructed using netOD. PACS number: 87 PMID:22766947

  7. Plasma cannabinoid concentrations during dronabinol pharmacotherapy for cannabis dependence.

    PubMed

    Milman, Garry; Bergamaschi, Mateus M; Lee, Dayong; Mendu, Damodara R; Barnes, Allan J; Vandrey, Ryan; Huestis, Marilyn A

    2014-04-01

    Recently, high-dose oral synthetic delta-9-tetrahydrocannabinol (THC) was shown to alleviate cannabis withdrawal symptoms. The present data describe cannabinoid pharmacokinetics in chronic, daily cannabis smokers who received high-dose oral THC pharmacotherapy and later a smoked cannabis challenge. Eleven daily cannabis smokers received 0, 30, 60, or 120 mg/d THC for four 5-day medication sessions, each separated by 9 days of ad libitum cannabis smoking. On the fifth day, participants were challenged with smoking one 5.9% THC cigarette. Plasma collected on the first and fifth days was quantified by two-dimensional gas chromatography mass spectrometer for THC, 11-hydroxy-THC (11-OH-THC), and 11-nor-9-carboxy-THC (THCCOOH). Linear ranges (ng/mL) were 0.5-100 for THC, 1-50 for 11-OH-THC, and 0.5-200 for THCCOOH. During placebo dosing, THC, 11-OH-THC, and THCCOOH concentrations consistently decreased, whereas all cannabinoids increased dose dependently during active dronabinol administration. THC increase over time was not significant after any dose, 11-OH-THC increased significantly during the 60- and 120-mg/d doses, and THCCOOH increased significantly only during the 120-mg/d dose. THC, 11-OH-THC, and THCCOOH concentrations peaked within 0.25 hours after cannabis smoking, except after 120 mg/d THC when THCCOOH peaked 0.5 hours before smoking. The significant withdrawal effects noted during placebo dronabinol administration were supported by significant plasma THC and 11-OH-THC concentration decreases. During active dronabinol dosing, significant dose-dependent increases in THC and 11-OH-THC concentrations support withdrawal symptom suppression. THC concentrations after cannabis smoking were only distinguishable from oral THC doses for 1 hour, too short a period to feasibly identify cannabis relapse. THCCOOH/THC ratios were higher 14 hours after overnight oral dronabinol abstinence but cannot distinguish oral THC dosing from the smoked cannabis intake.

  8. Plasma Cannabinoid Concentrations during Dronabinol Pharmacotherapy for Cannabis Dependence

    PubMed Central

    Milman, Garry; Bergamaschi, Mateus M.; Lee, Dayong; Mendu, Damodara R.; Barnes, Allan J.; Vandrey, Ryan; Huestis, Marilyn A.

    2013-01-01

    Background Recently, high-dose oral synthetic delta-9-tetrahydrocannabinol (THC) was shown to alleviate cannabis withdrawal symptoms. The present data describe cannabinoid pharmacokinetics in chronic daily cannabis smokers who received high-dose oral THC pharmacotherapy and later, a smoked cannabis challenge. Methods 11 daily cannabis smokers received 0, 30, 60, or 120 mg/day THC for four 5-day medication sessions, each separated by 9-days of ad-libitum cannabis smoking. On the 5th day, participants were challenged with smoking one 5.9% THC cigarette. Plasma collected on the 1st and 5th days was quantified by GC-GC-MS for THC, 11-hydroxy-THC (11-OH-THC), and 11-nor-9-carboxy-THC (THCCOOH). Linear ranges (ng/mL) were 0.5–100 for THC, 1–50 11-OH-THC, and 0.5–200 THCCOOH. Results During placebo dosing, THC, 11-OH-THC and THCCOOH concentrations consistently decreased, while all cannabinoids increased dose-dependently during active dronabinol administration. THC increase over time was not significant after any dose, 11-OH-THC increased significantly during 60 and 120 mg/day doses, and THCCOOH increased significantly only during the 120 mg/day dose. THC and 11-OH-THC, and THCCOOH concentrations peaked within 0.25 h after cannabis smoking, except after 120 mg/day THC when THCCOOH peaked 0.5 h before smoking. Conclusions The significant withdrawal effects noted during placebo dronabinol administration were supported by significant plasma THC and 11-OH-THC concentration decreases. During active dronabinol dosing, significant dose-dependent increases in THC and 11-OH-THC concentrations support withdrawal symptom suppression. THC concentrations after cannabis smoking were only distinguishable from oral THC doses for 1 h, too short a period to feasibly identify cannabis relapse. THCCOOH/THC ratios were higher 14 h after overnight oral dronabinol abstinence, but cannot distinguish oral THC dosing from smoked cannabis intake. PMID:24067260

  9. Extracting the normal lung dose-response curve from clinical DVH data: a possible role for low dose hyper-radiosensitivity, increased radioresistance

    NASA Astrophysics Data System (ADS)

    Gordon, J. J.; Snyder, K.; Zhong, H.; Barton, K.; Sun, Z.; Chetty, I. J.; Matuszak, M.; Ten Haken, R. K.

    2015-09-01

    In conventionally fractionated radiation therapy for lung cancer, radiation pneumonitis’ (RP) dependence on the normal lung dose-volume histogram (DVH) is not well understood. Complication models alternatively make RP a function of a summary statistic, such as mean lung dose (MLD). This work searches over damage profiles, which quantify sub-volume damage as a function of dose. Profiles that achieve best RP predictive accuracy on a clinical dataset are hypothesized to approximate DVH dependence. Step function damage rate profiles R(D) are generated, having discrete steps at several dose points. A range of profiles is sampled by varying the step heights and dose point locations. Normal lung damage is the integral of R(D) with the cumulative DVH. Each profile is used in conjunction with a damage cutoff to predict grade 2 plus (G2+) RP for DVHs from a University of Michigan clinical trial dataset consisting of 89 CFRT patients, of which 17 were diagnosed with G2+ RP. Optimal profiles achieve a modest increase in predictive accuracy—erroneous RP predictions are reduced from 11 (using MLD) to 8. A novel result is that optimal profiles have a similar distinctive shape: enhanced damage contribution from low doses (<20 Gy), a flat contribution from doses in the range ~20-40 Gy, then a further enhanced contribution from doses above 40 Gy. These features resemble the hyper-radiosensitivity / increased radioresistance (HRS/IRR) observed in some cell survival curves, which can be modeled using Joiner’s induced repair model. A novel search strategy is employed, which has the potential to estimate RP dependence on the normal lung DVH. When applied to a clinical dataset, identified profiles share a characteristic shape, which resembles HRS/IRR. This suggests that normal lung may have enhanced sensitivity to low doses, and that this sensitivity can affect RP risk.

  10. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Safari, M. J.; Wong, J. H. D.; Ng, K. H., E-mail: ngkh@um.edu.my

    2015-05-15

    Purpose: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. Methods: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualitiesmore » were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. Results: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (±1%), field size (±1%), frame rate (±3%), or beam energy (±5%). The detector angular dependence was within ±5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ±3%. Conclusions: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.« less

  11. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures.

    PubMed

    Safari, M J; Wong, J H D; Ng, K H; Jong, W L; Cutajar, D L; Rosenfeld, A B

    2015-05-01

    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (± 1%), field size (± 1%), frame rate (± 3%), or beam energy (± 5%). The detector angular dependence was within ± 5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ± 3%. The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.

  12. Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength.

    PubMed

    Raaijmakers, A J E; Raaymakers, B W; Lagendijk, J J W

    2008-02-21

    Several institutes are currently working on the development of a radiotherapy treatment system with online MR imaging (MRI) modality. The main difference between their designs is the magnetic field strength of the MRI system. While we have chosen a 1.5 Tesla (T) magnetic field strength, the Cross Cancer Institute in Edmonton will be using a 0.2 T MRI scanner and the company Viewray aims to use 0.3 T. The magnetic field strength will affect the severity of magnetic field dose effects, such as the electron return effect (ERE): considerable dose increase at tissue air boundaries due to returning electrons. This paper has investigated how the ERE dose increase depends on the magnetic field strength. Therefore, four situations where the ERE occurs have been simulated: ERE at the distal side of the beam, the lateral ERE, ERE in cylindrical air cavities and ERE in the lungs. The magnetic field comparison values were 0.2, 0.75, 1.5 and 3 T. Results show that, in general, magnetic field dose effects are reduced at lower magnetic field strengths. At the distal side, the ERE dose increase is largest for B = 0.75 T and depends on the irradiation field size for B = 0.2 T. The lateral ERE is strongest for B = 3 T but shows no effect for B = 0.2 T. Around cylindrical air cavities, dose inhomogeneities disappear if the radius of the cavity becomes small relative to the in-air radius of the secondary electron trajectories. At larger cavities (r > 1 cm), dose inhomogeneities exist for all magnetic field strengths. In water-lung-water phantoms, the ERE dose increase takes place at the water-lung transition and the dose decreases at the lung-water transition, but these effects are minimal for B = 0.2 T. These results will contribute to evaluating the trade-off between magnetic field dose effects and image quality of MR-guided radiotherapy systems.

  13. Dose-response analysis of testosterone replacement therapy in patients with female to male gender identity disorder.

    PubMed

    Nakamura, Aya; Watanabe, Masami; Sugimoto, Morito; Sako, Tomoko; Mahmood, Sabina; Kaku, Haruki; Nasu, Yasutomo; Ishii, Kazushi; Nagai, Atsushi; Kumon, Hiromi

    2013-01-01

    Gender identity disorder (GID) is a conflict between a person's actual physical gender and the one they identify him or herself with. Testosterone is the key agent in the medical treatment of female to male GID patients. We conducted a dose-response analysis of testosterone replacement therapy (TRT) in 138 patients to determine the onset of the therapeutic effects. The TRT consisted of intramuscular injection of testosterone enanthate and patients were divided into three groups; 250 mg every two weeks, 250 mg every three weeks and 125 mg every two weeks. The onset of deepening of voice, increase in facial hair and cessation of menses was evaluated in each group. At one month after the start of TRT, the onset of these physical changes was more prevalent in the group receiving the higher dose of testosterone, and there were dose-dependent effects observed between the three treatment groups. On the other hand, at six months after the start of TRT, most of the patients had achieved treatment responses and there were no dose-dependent effects with regard to the percentage of patients with therapeutic effects. No significant side effects were observed in any of the treatment groups. We demonstrated that the early onset of the treatment effects of TRT is dose-dependent, but within six months of starting TRT, all three doses were highly effective. Current study provides useful information to determine the initial dose of TRT and to suggest possible changes that should be made in the continuous dosage for long term TRT.

  14. Surface buildup dose dependence on photon field delivery technique for IMRT

    PubMed Central

    Yokoyama, Shigeru; Roberson, Peter L.; Litzenberg, Dale W.; Moran, Jean M.; Fraass, Benedick A.

    2004-01-01

    The more complex delivery techniques required for implementation of intensity‐modulated radiotherapy (IMRT) based on inverse planning optimization have changed the relationship between dose at depth and dose at buildup regions near the surface. Surface buildup dose is dependent on electron contamination primarily from the unblocked view of the flattening filter and secondarily from air and collimation systems. To evaluate the impact of beam segmentation on buildup dose, measurements were performed with 10×10 cm2 fields, which were delivered with 3 static 3.5×10 cm2 or 3×10 cm2 strips, 5 static 2×10 cm2 strips, 10 static 1×10 cm2 strips, and 1.1×10 cm2 dynamic delivery, compared with a 10×10 cm2 open field. Measurements were performed in water and Solid Water using parallel plate chambers, a stereotactic diode, and thermoluminescent dosimeters (TLDs) for a 6 MV X‐ray beam. Depth doses at 2 mm depth (relative to dose at 10 cm depth) were lower by 6%, 7%, 11%, and 10% for the above field delivery techniques, respectively, compared to the open field. These differences are most influenced by differences in multileaf collimator (MLC) transmission contributing to the useful beam. An example IMRT field was also studied to assess variations due to delivery technique (static vs. dynamic) and intensity level. Buildup dose is weakly dependent on the multileaf delivery technique for efficient IMRT fields. PACS numbers: 87.53.‐j, 87.53.Dq PMID:15738914

  15. Sex differences in the subjective effects of oral Δ9-THC in cannabis users.

    PubMed

    Fogel, Jessica S; Kelly, Thomas H; Westgate, Philip M; Lile, Joshua A

    2017-01-01

    Previous studies suggest that there are sex differences in endocannabinoid function and the response to exogenous cannabinoids, though data from clinical studies comparing acute cannabinoid effects in men and women under controlled laboratory conditions are limited. To further explore these potential differences, data from 30 cannabis users (N=18 M, 12 F) who completed previous Δ 9 -tetrahydrocannabinol (Δ 9 -THC) discrimination studies were combined for this retrospective analysis. In each study, subjects learned to discriminate between oral Δ 9 -THC and placebo and then received a range of Δ 9 -THC doses (0, 5, 15 and a "high" dose of either 25 or 30mg). Responses on a drug-discrimination task, subjective effects questionnaire, psychomotor performance tasks, and physiological measures were assessed. Δ 9 -THC dose-dependently increased drug-appropriate responding, ratings on "positive" Visual Analog Scale (VAS) items (e.g., good effects, like drug, take again), and items related to intoxication (e.g., high, stoned). Δ 9 -THC also dose-dependently impaired performance on psychomotor tasks and elevated heart rate. Sex differences on VAS items emerged as a function of dose. Women exhibited significantly greater subjective responses to oral drug administration than men at the 5mg Δ 9 -THC dose, whereas men were more sensitive to the subjective effects of the 15mg dose of Δ 9 -THC than women. These results demonstrate dose-dependent separation in the subjective response to oral Δ 9 -THC administration by sex, which might contribute to the differential development of problematic cannabis use. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. The total ozone and UV solar radiation over Stara Zagora, Bulgaria

    NASA Astrophysics Data System (ADS)

    Mendeva, B. D.; Gogosheva, Ts. N.; Petkov, B. H.; Krastev, D. G.

    The results from direct ground-based solar UV irradiance measurements and the total ozone content (TOC) over Stara Zagora (42° 25'N, 25° 37'E), Bulgaria are presented. During the period 1999-2003 the TOC data show seasonal variations, typical for the middle latitudes - maximum in the spring and minimum in the autumn. The comparison between TOC ground-based data and Global Ozone Monitoring Experiment (GOME) satellite-borne ones shows a seasonal dependence of the differences between them. A strong negative relationship between the total ozone and the 305 nm wavelength irradiance was found. The dependence between the two variables is significant ( r = -0.62 ± 0.18) at 98% confidence level. The direct sun UV doses for some specific biological effects (erythema and eyes) are obtained. The estimation of the radiation amplification factor RAF shows that the ozone reduction by 1% increases the erythemal dose by 2.3%. The eye-damaging doses are more influenced by the TOC changes and in this case RAF = -2.7%. The amount of these biological doses depended on the solar altitude over the horizon. This dependence was not so strong when the total ozone content in the atmosphere was lower.

  17. Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification

    PubMed Central

    Borca, Valeria Casanova; Russo, Giuliana; Grosso, Pierangelo; Cante, Domenico; Sciacero, Piera; Girelli, Giuseppe; Porta, Maria Rosa La; Tofani, Santi

    2013-01-01

    Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which is reported for EBT2 films. The most important EBT3 characteristics have been investigated, such as response at high‐dose levels, sensitivity to scanner orientation and postirradiation coloration, energy and dose rate dependence, and orientation dependence with respect to film side. Additionally, different IMRT fields were measured with both EBT3 and EBT2 films and evaluated using gamma index analysis. The results obtained show that most of the characteristics of EBT3 film are similar to the EBT2 film, but the orientation dependence with respect to film side is completely eliminated in EBT3 films. The study confirms that EBT3 film can be used for clinical practice in the same way as the previous EBT2 film. PACS number: 87.56.Fc PMID:23470940

  18. γ-Oryzanol reduces adhesion molecule expression in vascular endothelial cells via suppression of nuclear factor-κB activation.

    PubMed

    Sakai, Satoshi; Murata, Takahisa; Tsubosaka, Yoshiki; Ushio, Hideki; Hori, Masatoshi; Ozaki, Hiroshi

    2012-04-04

    γ-Oryzanol (γ-ORZ) is a mixture of phytosteryl ferulates purified from rice bran oil. In this study, we examined whether γ-ORZ represents a suppressive effect on the lipopolysaccharide (LPS)-induced adhesion molecule expression on vascular endothelium. Treatment with LPS elevated the mRNA expression of vascular cell adhesion molecule-1 (VCAM-1), intercellular adhesion molecule-1 (ICAM-1), and E-selectin in bovine aortic endothelial cells (BAECs). Pretreatment with γ-ORZ dose-dependently decreased the LPS-mediated expression of these genes. Western blotting also revealed that pretreatment with γ-ORZ dose-dependently inhibited LPS-induced VCAM-1 expression in human umbilical vein endothelial cells. Consistently, pretreatment with γ-ORZ dose-dependently reduced LPS-induced U937 monocyte adhesion to BAECs. In immunofluorescence, LPS caused nuclear factor-κB (NF-κB) nuclear translocation in 40% of BAECs, which indicates NF-κB activation. Pretreatment with γ-ORZ, as well as its components (cycloartenyl ferulate, ferulic acid, or cycloartenol), dose-dependently inhibited LPS-mediated NF-κB activation. Collectively, our results suggested that γ-ORZ reduced LPS-mediated adhesion molecule expression through NF-κB inhibition in vascular endothelium.

  19. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    NASA Technical Reports Server (NTRS)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  20. Juvenile Hormone Analogues, Methoprene and Fenoxycarb Dose-Dependently Enhance Certain Enzyme Activities in the Silkworm Bombyx Mori (L)

    PubMed Central

    Mamatha, Devi M.; Kanji, Vijaya K.; Cohly, Hari H.P.; Rao, M. Rajeswara

    2008-01-01

    Use of Juvenile Hormone Analogues (JHA) in sericulture practices has been shown to boost good cocoon yield; their effect has been determined to be dose-dependent. We studied the impact of low doses of JHA compounds such as methoprene and fenoxycarb on selected key enzymatic activities of the silkworm Bombyx mori. Methoprene and fenoxycarb at doses of 1.0 μg and 3.0fg/larvae/48 hours showed enhancement of the 5th instar B. mori larval muscle and silkgland protease, aspartate aminotransaminase (AAT) and alanine aminotransaminase (ALAT), adenosine triphosphate synthase (ATPase) and cytochrome-c-oxidase (CCO) activity levels, indicating an upsurge in the overall oxidative metabolism of the B.mori larval tissues. PMID:18678927

  1. DOSE-DEPENDENT TRANSITIONS IN MECHANISMS OF TOXICITY: CASE STUDIES

    EPA Science Inventory

    Experience with dose response and mechanisms of toxicity has shown that multiple mechanisms may exist for a single agent along the continuum of the full dose-response curve. It is highly likely that critical, limiting steps in any given mechanistic pathway may become overwhelmed ...

  2. COCAINE AND PAVLOVIAN FEAR CONDITIONING: DOSE-EFFECT ANALYSIS

    PubMed Central

    Wood, Suzanne C.; Fay, Jonathon; Sage, Jennifer R.; Anagnostaras, Stephan G.

    2007-01-01

    Emerging evidence suggests that cocaine and other drugs of abuse can interfere with many aspects of cognitive functioning. The authors examined the effects of 0.1 – 15 mg/kg of cocaine on Pavlovian contextual and cued fear conditioning in mice. As expected, pre-training cocaine dose-dependently produced hyperactivity and disrupted freezing. Surprisingly, when the mice were tested off-drug later, the group pre-treated with a moderate dose of cocaine (15 mg/kg) displayed significantly less contextual and cued memory, compared to saline control animals. Conversely, mice pre-treated with a very low dose of cocaine (0.1 mg/kg) showed significantly enhanced fear memory for both context and tone, compared to controls. These results were not due to cocaine’s anesthetic effects, as shock reactivity was unaffected by cocaine. The data suggest that despite cocaine’s reputation as a performance-enhancing and anxiogenic drug, this effect is seen only at very low doses, whereas a moderate dose disrupts hippocampus and amygdala-dependent fear conditioning. PMID:17098299

  3. Cocaine and Pavlovian fear conditioning: dose-effect analysis.

    PubMed

    Wood, Suzanne C; Fay, Jonathan; Sage, Jennifer R; Anagnostaras, Stephan G

    2007-01-25

    Emerging evidence suggests that cocaine and other drugs of abuse can interfere with many aspects of cognitive functioning. The authors examined the effects of 0.1-15mg/kg of cocaine on Pavlovian contextual and cued fear conditioning in mice. As expected, pre-training cocaine dose-dependently produced hyperactivity and disrupted freezing. Surprisingly, when the mice were tested off-drug later, the group pre-treated with a moderate dose of cocaine (15mg/kg) displayed significantly less contextual and cued memory, compared to saline control animals. Conversely, mice pre-treated with a very low dose of cocaine (0.1mg/kg) showed significantly enhanced fear memory for both context and tone, compared to controls. These results were not due to cocaine's anesthetic effects, as shock reactivity was unaffected by cocaine. The data suggest that despite cocaine's reputation as a performance-enhancing and anxiogenic drug, this effect is seen only at very low doses, whereas a moderate dose disrupts hippocampus and amygdala-dependent fear conditioning.

  4. Effect of topogram-tube angle combination on CT radiation dose reduction

    NASA Astrophysics Data System (ADS)

    Shim, J.; Yoon, M.

    2017-09-01

    This study assessed the ability of various types of topograms, when used with an automatic tube current modulation (ATCM) technique, to reduce radiation dose from computed tomography (CT) scans. Three types of topograms were used with the ATCM technique: (i) anteroposterior (AP) topograms alone, (ii) AP topograms followed by lateral topograms, and (iii) lateral topograms followed by AP topograms. Various regions (chest, abdomen and whole-body) of a humanoid phantom were scanned at several tube voltages (80, 100 and 120 kVp) with the selected topograms. Although the CT dose depended on the order of topograms, the CT dose with respect to patient positioning depended on the number of topograms performed. The magnitude of the difference in CT dose between number and order of topograms was greater for the scans of the abdomen than the chest. These results suggest that, for the Siemens SOMATOM Definition AS CT scanner, choosing the right combination of CT scan conditions with the ATCM technique can minimize radiation dose to a patient.

  5. Dosing-time-dependent variation in biliary excretion of flomoxef in rats.

    PubMed

    Hishikawa, Shuji; Sugimoto, Koh-ichi; Kobayashi, Eiji; Kumagai, Yuji; Fujimura, Akio

    2003-05-01

    We previously reported that the biliary excretion of flomoxef, an oxacephem antibiotic, was greater after dosing at 21:00 than at 09:00 h in diurnally active human subjects. The present study was undertaken to examine whether the biliary excretion of flomoxef is also dependent on its dosing time in rats. Adult male Wistar rats were housed under light on at 07:00 h and off at 19:00 h. Bile fluid was completely drained through a polyethylene catheter from conscious animals. Flomoxef (20 mg/kg) was injected into the tail vein at 09:00 or 21:00 h by a cross-over design, and drained bile fluid was collected for 8 h after each dosing. The maximum concentration of biliary flomoxef was significantly greater and its total excretion tended to be greater after dosing at 09:00 than 21:00 h. These results suggest the biliary excretion of flomoxef is enhanced after dosing at the beginning of the rest period in rats, as it is in humans.

  6. Clinical application of the OneDose Patient Dosimetry System for total body irradiation.

    PubMed

    Best, S; Ralston, A; Suchowerska, N

    2005-12-21

    The OneDose Patient Dosimetry System (Sicel Technologies) is a new dosimeter based on metal oxide semiconductor field-effect transistor technology and designed for the in vivo measurement of patient dose during radiotherapy. In vivo dosimetry for total body irradiation (TBI) is challenging due to the extended treatment distance, low dose rates and beam spoilers. Phantom results confirm the suitability of the dosimeter for TBI in terms of inherent build-up, post-irradiation fading, accuracy, reproducibility, linearity and temperature dependence. Directional dependence is significant and should be taken into account. The OneDose dosimeters were also trialed in vivo for two TBI patients and the dose measured compared to conventional dosimeter measurements using an ionization chamber and thermoluminescent dosimeters (TLD), with agreement to within 2.2% and 3.9%, respectively. Phantom and patient results confirm that the OneDose patient dosimetry system is a practical and convenient alternative to TLDs for TBI in vivo dosimetry. For increased confidence in results with this dosimeter, we recommend that two dosimeters be used for each site of interest.

  7. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    PubMed

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies <60 and >80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Characteristics of an OSLD in the diagnostic energy range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Senan, Rani M.; Hatab, Mustapha R.

    2011-07-15

    Purpose: Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. Methods: NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energymore » dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Results: Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R{sup 2} > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 deg. in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). Conclusions: OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.« less

  9. Necroptosis contributes to methamphetamine-induced cytotoxicity in rat cortical neurons.

    PubMed

    Xiong, Kun; Liao, Huidan; Long, Lingling; Ding, Yanjun; Huang, Jufang; Yan, Jie

    2016-09-01

    Necroptosis, a programmed necrosis, is involved in various types of neurodegenerative diseases. In this study, we investigated whether necroptosis contributed to neuronal damage in a methamphetamine injury model. Primary cultures of embryonic cortical neurons from Sprague-Dawley rats were subjected to different doses of methamphetamine with/without pre-treatment with a specific necroptosis inhibitor, Necrostatin-1. Necrosis was assessed by determining lactate dehydrogenase release and by Annexin V/propidium iodide double staining, while the neuronal ultra-structure was examined by electron microscopy. Tumor necrosis factor-α protein levels were determined by enzyme-linked immunosorbent assay. At early stages (12h) of post-treatment with methamphetamine, significant necrosis occurred and the viability of neurons decreased in a dose- and time-dependent manner in this model of acute neuronal injury. Pretreatment with Necrostatin-1 led to significant neuronal preservation compared with the methamphetamine-treated groups. Furthermore, tumor necrosis factor-α expression increased in a dose-dependent manner following methamphetamine exposure. Methamphetamine induced necrosis in rat cortical neurons in vitro, both time and dose dependently, and necroptosis may be an important newly identified mode of cortical neuronal death caused by single high-dose methamphetamine administration. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Influence of serotonin and melatonin on some parameters of gastrointestinal activity.

    PubMed

    Bubenik, G A; Dhanvantari, S

    1989-01-01

    In vitro melatonin (M) reduced the tone of gut muscles and counteracted the tonic effect of serotonin (5-HT). In vivo 0.1 to 4 mg of 5-HT (contained in beeswax implants) decreased the food transit time (FTT) in a dose-dependent manner, but higher doses (5 and 6 mg) increased the FTT. Melatonin injected intraperitoneally into mice bearing 5-HT implants (2 mg per animal) blocked partly the serotonin effect and increased FTT by 50%; however, no dose-dependent effect was observed when doses between 0.01 and 1 mg were used. Surprisingly, M injected into intact mice decreased FTT to levels comparable to those observed in 5-HT implanted, M-treated mice. Again, this significant decrease was not dose-dependent between 0.02 and 1 mg. Although in vitro the maximal inhibition of serotonin-induced spasm was achieved when the M:5-HT ratio was 50-100:1, in vivo the effective ratio was about 1:1. This may indicate that part of M action on the gut movement is mediated by extraintestinal mechanisms. A hypothetical, counterbalancing system of M and 5-HT regulation of gut activity (similar to adrenaline-acetylcholine system) is proposed.

  11. Determining the applicability of the Landauer nanoDot as a general public dosimeter in a research imaging facility.

    PubMed

    Charlton, Michael A; Thoreson, Kelly F; Cerecero, Jennifer A

    2012-11-01

    The Research Imaging Institute (RII) building at the University of Texas Health Science Center at San Antonio (UTHSCSA) houses two cyclotron particle accelerators, positron emission tomography (PET) machines, and a fluoroscopic unit. As part of the radiation protection program (RPP) and meeting the standard for achieving ALARA (as low as reasonably achievable), it is essential to minimize the ionizing radiation exposure to the general public through the use of controlled areas and area dose monitoring. Currently, thirty-four whole body Luxel+ dosimeters, manufactured by Landauer, are being used in various locations within the RII to monitor dose to the general public. The intent of this research was to determine if the nanoDot, a single point dosimeter, can be used as a general public dosimeter in a diagnostic facility. This was tested by first verifying characteristics of the nanoDot dosimeter including dose linearity, dose rate dependence, angular dependence, and energy dependence. Then, the response of the nanoDot dosimeter to the Luxel+ dosimeter when placed in a continuous, low dose environment was investigated. Finally, the nanoDot was checked for appropriate response in an acute, high dose environment. Based on the results, the current recommendation is that the nanoDot should not replace the Luxel+ dosimeter without further work to determine the energy spectra in the RII building and without considering the limitation of the microStar reader, portable on-site OSL reader, at doses below 0.1 mGy (10 mrad).

  12. Near infrared radio-luminescence of O{sub 2} loaded radiation hardened silica optical fibers: A candidate dosimeter for harsh environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Francesca, D., E-mail: diego.di.francesca@univ-st-etienne.fr; Dipartimento di Fisica e Chimica, Università degli Studi di Palermo, I-90123 Palermo; Girard, S.

    2014-11-03

    We report on an experimental investigation of the infrared Radio-Luminescence (iRL) emission of interstitial O{sub 2} molecules loaded in radiation hardened pure-silica-core and fluorine-doped silica-based optical fibers (OFs). The O{sub 2} loading treatment successfully dissolved high concentrations of oxygen molecules into the silica matrix. A sharp luminescence at 1272 nm was detected when 2.5 cm of the treated OFs were irradiated with 10 keV X-rays. This emission originates from the radiative decay of the first excited singlet state of the embedded O{sub 2} molecules. The dose, dose-rate, and temperature dependencies of the infrared emission are studied through in situ optical measurements. The resultsmore » show that the iRL is quite stable in doses of up to 1 MGy(SiO{sub 2}) and is linearly dependent on the dose-rate up to the maximum investigated dose-rate of ∼200 kGy(SiO{sub 2})/h. The temperature dependency of the iRL shows a decrease in efficiency above 200 °C, which is attributed to the non-radiative decay of the excited O{sub 2} molecules. The results obtained and the long-term stability of the O{sub 2}-loading treatment (no out-gassing effect) strongly suggest the applicability of these components to real-time remote dosimetry in environments characterized by high radiation doses and dose-rates.« less

  13. Dose-dependent cytotoxicity evaluation of graphite nanoparticles for diamond-like carbon film application on artificial joints.

    PubMed

    Liao, T T; Deng, Q Y; Wu, B J; Li, S S; Li, X; Wu, J; Leng, Y X; Guo, Y B; Huang, N

    2017-01-24

    While a diamond-like carbon (DLC)-coated joint prosthesis represents the implant of choice for total hip replacement in patients, it also leads to concern due to the cytotoxicity of wear debris in the form of graphite nanoparticles (GNs), ultimately limiting its clinical use. In this study, the cytotoxicity of various GN doses was evaluated. Mouse macrophages and osteoblasts were incubated with GNs (<30 nm diameter), followed by evaluation of cytotoxicity by means of assessing inflammatory cytokines, results of alkaline phosphatase assays, and related signaling protein expression. Cytotoxicity evaluation showed that cell viability decreased in a dose-dependent manner (10-100 μg ml -1 ), and steeply declined at GNs concentrations greater than 30 μg ml -1 . Noticeable cytotoxicity was observed as the GN dose exceeded this threshold due to upregulated receptor of activator of nuclear factor kB-ligand expression and downregulated osteoprotegerin expression. Meanwhile, activated macrophage morphology was observed as a result of the intense inflammatory response caused by the high doses of GNs (>30 μg ml -1 ), as observed by the increased release of TNF-α and IL-6. The results suggest that GNs had a significant dose-dependent cytotoxicity in vitro, with a lethal dose of 30 μg ml -1 leading to dramatic increases in cytotoxicity. Our GN cytotoxicity evaluation indicates a safe level for wear debris-related arthropathy and could propel the clinical application of DLC-coated total hip prostheses.

  14. Ibogaine for treating drug dependence. What is a safe dose?

    PubMed

    Schep, L J; Slaughter, R J; Galea, S; Newcombe, D

    2016-09-01

    The indole alkaloid ibogaine, present in the root bark of the West African rain forest shrub Tabernanthe iboga, has been adopted in the West as a treatment for drug dependence. Treatment of patients requires large doses of the alkaloid to cause hallucinations, an alleged integral part of the patient's treatment regime. However, case reports and case series continue to describe evidences of ataxia, gastrointestinal distress, ventricular arrhythmias and sudden and unexplained deaths of patients undergoing treatment for drug dependence. High doses of ibogaine act on several classes of neurological receptors and transporters to achieve pharmacological responses associated with drug aversion; limited toxicology research suggests that intraperitoneal doses used to successfully treat rodents, for example, have also been shown to cause neuronal injury (purkinje cells) in the rat cerebellum. Limited research suggests lethality in rodents by the oral route can be achieved at approximately 263mg/kg body weight. To consider an appropriate and safe initial dose for humans, necessary safety factors need to be applied to the animal data; these would include factors such as intra- and inter-species variability and for susceptible people in a population (such as drug users). A calculated initial dose to treat patients could be approximated at 0.87mg/kg body weight, substantially lower than those presently being administered to treat drug users. Morbidities and mortalities will continue to occur unless practitioners reconsider doses being administered to their susceptible patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Dose-dependent effects of hydrocortisone infusion on autobiographical memory recall

    PubMed Central

    Young, Kymberly; Drevets, Wayne C.; Schulkin, Jay; Erickson, Kristine

    2011-01-01

    The glucocorticoid hormone cortisol has been shown to impair episodic memory performance. The present study examined the effect of two doses of hydrocortisone (synthetic cortisol) administration on autobiographical memory retrieval. Healthy volunteers (n=66) were studied on two separate visits, during which they received placebo and either moderate-dose (0.15 mg/kg IV; n=33) or high-dose (0.45 mg/kg IV; n=33) hydrocortisone infusion. From 75 to 150 min post-infusion subjects performed an Autobiographical Memory Test and the California Verbal Learning Test (CVLT). The high-dose hydrocortisone administration reduced the percent of specific memories recalled (p = 0.04), increased the percent of categorical (nonspecific) memories recalled, and slowed response times for categorical memories (p <0.001), compared to placebo performance (p < 0.001). Under moderate-dose hydrocortisone the autobiographical memory performance did not change significantly with respect to percent of specific or categorical memories recalled or reaction times. Performance on the CVLT was not affected by hydrocortisone. These findings suggest that cortisol affects accessibility of autobiographical memories in a dose-dependent manner. Specifically, administration of hydrocortisone at doses analogous to those achieved under severe psychosocial stress impaired the specificity and speed of retrieval of autobiographical memories. PMID:21942435

  16. Evaluation of Gamma Radiation-Induced Biochemical Changes in Skin for Dose Assesment: A Study on Small Experimental Animals.

    PubMed

    Kumar Soni, Sandeep; Basu, Mitra; Agrawal, Priyanka; Bhatnagar, Aseem; Chhillar, Neelam

    2018-05-24

    Researchers have been evaluating several approaches to assess acute radiation injury/toxicity markers owing to radiation exposure. Keeping in mind this background, we assumed that whole-body irradiation in single fraction in graded doses can affect the antioxidant profile in skin that could be used as an acute radiation injury/toxicity marker. Sprague-Dawley rats were treated with CO-60 gamma radiation (dose: 1-5 Gy; dose rate: 0.85 Gy/minute). Skin samples were collected (before and after radiation up to 72 hours) and analyzed for glutathione (GSH), glutathione peroxidase (GPx), superoxide dismutase (SOD), catalase (CAT), and lipid peroxidation (LPx). Intra-group comparison showed significant differences in GSH, GPx, SOD, and CAT, and they declined in a dose-dependent manner from 1 to 5 Gy (P value0.05). This study suggests that skin antioxidants were sensitive toward radiation even at a low radiation dose, which can be used as a predictor of radiation injury and altered in a dose-dependent manner. These biochemical parameters may have wider application in the evaluation of radiation-induced skin injury and dose assessment. (Disaster Med Public Health Preparedness. 2018;page 1 of 6).

  17. Dual role of betel leaf extract on thyroid function in male mice.

    PubMed

    Panda, S; Kar, A

    1998-12-01

    The effects of betel leaf extract (0.10, 0.40, 0.80 and 2.0 g kg-1 day-1 for 15 days) on the alterations in thyroid hormone concentrations. lipid peroxidation (LPO) and on the activities of superoxide dismutase (SOD) and catalase (CAT) were investigated in male Swiss mice. Administration of betel leaf extract exhibited a dual role, depending on the different doses. While the lowest dose decreased thyroxine (T4) and increased serum triiodothyronine (T3) concentrations, reverse effects were observed at two higher doses. Higher doses also increased LPO with a concomitant decrease in SOD and CAT activities. However, with the lowest dose most of these effects were reversed. These findings suggest that betel leaf can be both stimulatory and inhibitory to thyroid function, particularly for T3 generation and lipid peroxidation in male mice, depending on the amount consumed.

  18. Dose-related cerebellar abnormality in rats with prenatal exposure to X-irradiation by magnetic resonance imaging volumetric analysis.

    PubMed

    Sawada, Kazuhiko; Saito, Shigeyoshi; Horiuchi-Hirose, Miwa; Mori, Yuki; Yoshioka, Yoshichika; Murase, Kenya

    2013-09-01

    Cerebellar abnormalities in 4-week-old rats with a single whole body X-irradiation at a dose of 0.5, 1.0, or 1.5 Gy on embryonic day (ED) 15 were examined by magnetic resonance imaging (MRI) volumetry. A 3D T2 W-MRI anatomical sequence with high-spatial resolution at 11.7-tesla was acquired from the fixed rat heads. By MRI volumetry, whole cerebellar volumes decreased dose-dependently. Multiple linear regression analysis revealed that the cortical volume (standardized β=0.901; P<0.001) was a major explanatory variable for the whole cerebellar volume, whereas both volumes of the white matter and deep cerebellar nuclei also decreased depending on the X-irradiation dose. The present MRI volumetric analysis revealed a dose-related cerebellar cortical hypoplasia by prenatal exposure to X-irradiation on E15. © 2013 The Authors. Congenital Anomalies © 2013 Japanese Teratology Society.

  19. Retention of ion-implanted-xenon in olivine: Dependence on implantation dose

    NASA Technical Reports Server (NTRS)

    Melcher, C. L.; Tombrello, T. A.; Burnett, D. S.

    1982-01-01

    The diffusion of Xe in olivine, a major mineral in both meteorites and lunar samples, was studied. Xe ions were implanted at 200 keV into single-crystal synthetic-forsterite targets and the depth profiles were measured by alpha particle backscattering before and after annealing for 1 hour at temperatures up to 1500 C. The fraction of implanted Xe retained following annealing was strongly dependent on the implantation dose. Maximum retention of 100% occurred for an implantion dose of 3 x 10 to the 15th power Xe ions/sq cm. Retention was less at lower doses, with (approximately more than or = 50% loss at one hundred trillion Xe ions/sq cm. Taking the diffusion coefficient at this dose as a lower limit, the minimum activation energy necessary for Xe retention in a 10 micrometer layer for ten million years was calculated as a function of metamorphic temperature.

  20. Combined treatment using irradiation and heat: Susceptibility of bacillus, salmonella, staphylococcus and clostridium

    NASA Astrophysics Data System (ADS)

    Vincent, F.; Tibi, A.; Goury, V.; Darbord, J. C.

    The development of irradiation for food preservation is dependant on good process for choosing the doses. The reduction of the doses is particularly suitable, not only for the cost, but for organoleptic qualities of food. Many studies have demonstrated that Bacillus, Salmonella, Staphylococcus and Clostridium species are frequently isolated from food. The objective of this work is to prove the efficiency of combined treatments using irradiation and temperature (80°C), to reduce the dose of irradiation and the organoleptic alterations of food. The results are dependant on environmental conditions of the bacteria.

  1. Cross state-dependency of learning between arachidonylcyclopropylamide (ACPA) and muscimol in the mouse dorsal hippocampus.

    PubMed

    Jafari-Sabet, Majid; Karimi, Amir-Mohammad

    2017-12-01

    The aim of the present study was to examine cross state-dependent learning between ACPA (a selective cannabinoid CB1 receptor agonist) and muscimol (a selective GABAA receptor agonist) in the step-down inhibitory avoidance learning task. The dorsal hippocampal CA1 regions of adult male NMRI mice were bilaterally cannulated, and all drugs were microinjected into the intended sites of injection. Post-training and/or pre-test administration of ACPA (1 and 2ng/mouse) dose-dependently induced amnesia. Pre-test microinjection of the same doses of ACPA reversed the post-training ACPA-induced amnesia. This event has been named ACPA state-dependent learning (SDL). Post-training and/or pre-test microinjection of muscimol (0.05 and 0.1μg/mouse) dose-dependently induced amnesia. Pre-test administration of the same doses of muscimol reversed the post-training muscimol-induced amnesia, suggesting muscimol SDL. The amnesia induced by post-training administration of ACPA was reversed by pre-test administration of muscimol (0.05 and 0.1μg/mouse). Furthermore, the pre-test microinjection of muscimol (0.025 and 0.05μg/mouse) with an ineffective dose of ACPA (0.5ng/mouse) significantly restored memory retrieval and induced ACPA SDL. In another series of experiments, the amnesia induced by post-training administration of muscimol was reversed by pre-test administration of ACPA (1 and 2ng/mouse). Moreover, pre-test microinjection of ACPA (0.5 and 1ng/mouse) with an ineffective dose of muscimol (0.025μg/mouse) significantly restored memory retrieval and induced muscimol SDL. It is important to note that pre-test intra-CA1 injection of a selective GABAA receptor antagonist, bicuculline (0.125 and 0.25μg/mouse), 5min before the administration of muscimol (0.1μg/mouse) or ACPA (2ng/mouse) dose-dependently inhibited muscimol- and ACPA-induced SDL, respectively. Pre-test intra-CA1 administration of bicuculline (0.0625, 0.125 and 0.25μg/mouse) by itself did not affect memory retention. In conclusion, the data strongly revealed a cross SDL among ACPA and muscimol in the dorsal hippocampal CA1 regions. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. A review: Development of a microdose model for analysis of adaptive response and bystander dose response behavior.

    PubMed

    Leonard, Bobby E

    2008-02-27

    Prior work has provided incremental phases to a microdosimetry modeling program to describe the dose response behavior of the radio-protective adaptive response effect. We have here consolidated these prior works (Leonard 2000, 2005, 2007a, 2007b, 2007c) to provide a composite, comprehensive Microdose Model that is also herein modified to include the bystander effect. The nomenclature for the model is also standardized for the benefit of the experimental cellular radio-biologist. It extends the prior work to explicitly encompass separately the analysis of experimental data that is 1.) only dose dependent and reflecting only adaptive response radio-protection, 2.) both dose and dose-rate dependent data and reflecting only adaptive response radio-protection for spontaneous and challenge dose damage, 3.) only dose dependent data and reflecting both bystander deleterious damage and adaptive response radio-protection (AR-BE model). The Appendix cites the various applications of the model. Here we have used the Microdose Model to analyze the, much more human risk significant, Elmore et al (2006) data for the dose and dose rate influence on the adaptive response radio-protective behavior of HeLa x Skin cells for naturally occurring, spontaneous chromosome damage from a Brachytherapy type (125)I photon radiation source. We have also applied the AR-BE Microdose Model to the Chromosome inversion data of Hooker et al (2004) reflecting both low LET bystander and adaptive response effects. The micro-beam facility data of Miller et al (1999), Nagasawa and Little (1999) and Zhou et al (2003) is also examined. For the Zhou et al (2003) data, we use the AR-BE model to estimate the threshold for adaptive response reduction of the bystander effect. The mammogram and diagnostic X-ray induction of AR and protective BE are observed. We show that bystander damage is reduced in the similar manner as spontaneous and challenge dose damage as shown by the Azzam et al (1996) data. We cite primary unresolved questions regarding adaptive response behavior and bystander behavior. The five features of major significance provided by the Microdose Model so far are 1. Single Specific Energy Hits initiate Adaptive Response. 2. Mammogram and diagnostic X-rays induce a protective Bystander Effect as well as Adaptive Response radio-protection. 3. For mammogram X-rays the Adaptive Response protection is retained at high primer dose levels. 4. The dose range of the AR protection depends on the value of the Specific Energy per Hit, 1 >. 5. Alpha particle induced deleterious Bystander damage is modulated by low LET radiation.

  3. Investigating the Linear Dependence of Direct and Indirect Radiative Forcing on Emission of Carbonaceous Aerosols in a Global Climate Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yanju; Wang, Hailong; Singh, Balwinder

    The linearity of dependence of aerosol direct and indirect radiative forcing (DRF and IRF) on emissions is essential to answer the policy-relevant question on how the change in forcing would result from a change in emission. In this study, the forcing-to-emission relationship is investigated for black carbon (BC) and primary organic carbon (OC) emitted from North America and Asia. Direct and indirect radiative forcing of BC and OC are simulated with the Community Atmosphere Model (CAM5.1). Two diagnostics are introduced to aid in policy-relevant discussion: emission-normalized forcing (ENF) and linearity (R). DRF is linearly related to emission for both BCmore » and OC from the two regions and emission-normalized DRF is similar, within 15%. IRF is linear to emissions for weaker sources and regions far from source (North American BC and OC), while for large emission sources and near source regions (Asian OC) the response of forcing to emission is sub-linear. In North America emission-normalized IRF (ENIRF) is 2-4 times higher than that in Asia. The difference among regions and species is primarily caused by failure of accumulation mode particles to become CCN, and then to activate into CDNC. Optimal aggregation area (30ºx 30º) has been used to communicate the regional variation of forcing-to-emission relationship. For IRF, only 15-40% of the Earth’s surface is significantly affected by the two emission regions, but the forcing in these regions comprises most of the global impact. Linearity of IRF occurs in about two-thirds of the significant regions except for Asian OC. ENF is an effective tool to estimate forcing changes due to reduction of surface emissions, as long as there is sufficient attention to the causes of nonlinearity in the simulations used to derive ENIRF (emission into polluted regions and emission elevation). The differences in ENIRF have important implications for policy decisions. Lower ENIRF in more polluted region like Asia means that reductions of large amounts of OC in these regions would be relatively climate-neutral rather than causing significant warming via IRF reduction.« less

  4. Evaluation of the stepwise collimation method for the reduction of the patient dose in full spine radiography

    NASA Astrophysics Data System (ADS)

    Lee, Boram; Lee, Sunyoung; Yang, Injeong; Yoon, Myeonggeun

    2014-05-01

    The purpose of this study is to evaluate the dose reduction when using the stepwise collimation method for scoliosis patients undergoing full spine radiography. A Monte Carlo simulation was carried out to acquire dose vs. volume data for organs at risk (OAR) in the human body. While the effective doses in full spine radiography were reduced by 8, 15, 27 and 44% by using four different sizes of the collimation, the doses to the skin were reduced by 31, 44, 55 and 66%, indicating that the reduction of the dose to the skin is higher than that to organs inside the body. Although the reduction rates were low for the gonad, being 9, 14, 18 and 23%, there was more than a 30% reduction in the dose to the heart, suggesting that the dose reduction depends significantly on the location of the OARs in the human body. The reduction rate of the secondary cancer risk based on the excess absolute risk (EAR) varied from 0.6 to 3.4 per 10,000 persons, depending on the size of the collimation. Our results suggest that the stepwise collimation method in full spine radiography can effectively reduce the patient dose and the radiation-induced secondary cancer risk.

  5. In vitro comparison of the antiproliferative effects of rhenium-186 and rhenium-188 on human aortic endothelial cells.

    PubMed

    Sauter, Alexander; Arthasana, Daniel; Dittmann, Helmut; Pritzkow, Maren; Wiesinger, Benjamin; Schmehl, Joerg; Brechtel, Klaus; Bantleon, Rüdiger; Claussen, Claus; Kehlbach, Rainer

    2011-08-01

    Rhenium-186 ((186)Re) and rhenium-188 ((188)Re) are promising radionuclides for the inhibition of restenosis after percutaneous transluminal angioplasty or other vascular interventions. Until now the maximal dose tolerance of endothelial cells has not been clearly known. To characterize the effects of local irradiation treatment, human aortic endothelial cells (ECs) were incubated with different doses of (186)Re and (188)Re. Two days after plating, ECs received treatment for a period of 5 days. The total radiation doses applied were 1, 4, 8, 16, and 32 Gy. On days 1, 3, 5, 7, and 12 after initial rhenium incubation, cell growth, clonogenic activity, cell-cycle distribution, and cytoskeletal architecture were evaluated. From the first day on, a dose-dependent growth inhibition was observed. Cumulative doses of ≥32 Gy caused a weak colony formation and significant alterations in the cytoskeletal architecture. An increased fraction of cells in G2/M phase was seen for cumulative radiation doses of ≥16 Gy. Interestingly, there were no significant differences between (186)Re and (188)Re. Even for low dose rates of β particles a dose-dependent proliferation inhibition of ECs is seen. Doses beyond 32 Gy alter the cytoskeletal architecture with possibly endothelial dysfunction and late thrombosis.

  6. Real-time dosimetry in radiotherapy using tailored optical fibers

    NASA Astrophysics Data System (ADS)

    Rahman, A. K. M. Mizanur; Zubair, H. T.; Begum, Mahfuza; Abdul-Rashid, H. A.; Yusoff, Z.; Omar, Nasr Y. M.; Ung, N. M.; Mat-Sharif, K. A.; Bradley, D. A.

    2016-05-01

    Real-time dosimetry plays an important role for accurate patient-dose measurement during radiotherapy. A tiny piece of laboratory fabricated Ge-doped optical fiber has been investigated as a radioluminescence (RL) sensor for real-time dosimetry over the dose range from 1 Gy to 8 Gy under 6 MV photon beam by LINAC. Fiber-coupled software-based RL prototype system was used to assess essential dosimetric characteristics including dose response linearity, dose rate dependency, sensitivity, repeatability and output dependence on field sizes. The consistency level of RL photon counts versus dose rate was also compared with that of standard Al2O3:C chips. Sensitivity of Ge-doped fiber were found to be sufficiently sensitive for practical use and also provided linear dose responses for various dose rates from 100 cGy/min to 600 cGy/min using both 6 MV photon and 6 MeV electron beams. SEM-EDX analysis was performed to identify Ge-dopant concentration level within the optical fiber RL material. Accumulated doses were also estimated using simple integral technique and the error was found to be around less than 1% under dissimilar dose rates or repeat measurements. The evaluation of the Ge-doped optical fiber based RL dosimeter system indicates its potential in medical dosimetry.

  7. Lower Current Large Deviations for Zero-Range Processes on a Ring

    NASA Astrophysics Data System (ADS)

    Chleboun, Paul; Grosskinsky, Stefan; Pizzoferrato, Andrea

    2017-04-01

    We study lower large deviations for the current of totally asymmetric zero-range processes on a ring with concave current-density relation. We use an approach by Jensen and Varadhan which has previously been applied to exclusion processes, to realize current fluctuations by travelling wave density profiles corresponding to non-entropic weak solutions of the hyperbolic scaling limit of the process. We further establish a dynamic transition, where large deviations of the current below a certain value are no longer typically attained by non-entropic weak solutions, but by condensed profiles, where a non-zero fraction of all the particles accumulates on a single fixed lattice site. This leads to a general characterization of the rate function, which is illustrated by providing detailed results for four generic examples of jump rates, including constant rates, decreasing rates, unbounded sublinear rates and asymptotically linear rates. Our results on the dynamic transition are supported by numerical simulations using a cloning algorithm.

  8. Differential and relaxed image foresting transform for graph-cut segmentation of multiple 3D objects.

    PubMed

    Moya, Nikolas; Falcão, Alexandre X; Ciesielski, Krzysztof C; Udupa, Jayaram K

    2014-01-01

    Graph-cut algorithms have been extensively investigated for interactive binary segmentation, when the simultaneous delineation of multiple objects can save considerable user's time. We present an algorithm (named DRIFT) for 3D multiple object segmentation based on seed voxels and Differential Image Foresting Transforms (DIFTs) with relaxation. DRIFT stands behind efficient implementations of some state-of-the-art methods. The user can add/remove markers (seed voxels) along a sequence of executions of the DRIFT algorithm to improve segmentation. Its first execution takes linear time with the image's size, while the subsequent executions for corrections take sublinear time in practice. At each execution, DRIFT first runs the DIFT algorithm, then it applies diffusion filtering to smooth boundaries between objects (and background) and, finally, it corrects possible objects' disconnection occurrences with respect to their seeds. We evaluate DRIFT in 3D CT-images of the thorax for segmenting the arterial system, esophagus, left pleural cavity, right pleural cavity, trachea and bronchi, and the venous system.

  9. Room-temperature photodetection dynamics of single GaN nanowires.

    PubMed

    González-Posada, F; Songmuang, R; Den Hertog, M; Monroy, E

    2012-01-11

    We report on the photocurrent behavior of single GaN n-i-n nanowires (NWs) grown by plasma-assisted molecular-beam epitaxy on Si(111). These structures present a photoconductive gain in the range of 10(5)-10(8) and an ultraviolet (350 nm) to visible (450 nm) responsivity ratio larger than 6 orders of magnitude. Polarized light couples with the NW geometry with a maximum photoresponse for polarization along the NW axis. The photocurrent scales sublinearly with optical power, following a I ~ P(β) law (β < 1) in the measured range with β increasing with the measuring frequency. The photocurrent time response remains in the millisecond range, which is in contrast to the persistent (hours) photoconductivity effects observed in two-dimensional photoconductors. The photocurrent is independent of the measuring atmosphere, either in the air or in vacuum. Results are interpreted taking into account the effect of surface states and the total depletion of the NW intrinsic region. © 2011 American Chemical Society

  10. Fibronectin-based multilayer thin films.

    PubMed

    Gand, Adeline; Tabuteau, Maud; Chat, Coline; Ladam, Guy; Atmani, Hassan; Van Tassel, Paul R; Pauthe, Emmanuel

    2017-08-01

    Thin films mimicking the structure and composition of the extra-cellular matrix (ECM) are potentially attractive as biomaterials for cell contacting applications. Layer-by-layer (LbL) assembly of a biological polycation, poly(l-lysine) (PLL), and a common ECM protein, fibronectin (Fn), was employed here to construct nanoscale, ECM mimicking films. Incremental film thickness and interfacial charge magnitude are observed to diminish with layer number, resulting in sub-linear film growth scaling and saturation after about 10 layers. Infrared spectroscopy and electron microscopy together reveal the formation of Fn containing aggregates, whose presence correlates with diminished charge reversal and suppressed LbL assembly. PLL-Fn films induce a significantly greater murine MC3T3-E1 pre-osteoblastic cell proliferation, while maintaining a much higher proportion of Fn in the molecular (as opposed to fibrillar) state, compared to a Fn monolayer, suggesting the enhanced Fn content of these ECM-mimicking films to significantly, and positively, affect cell behavior. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Template-Directed Copolymerization, Random Walks along Disordered Tracks, and Fractals

    NASA Astrophysics Data System (ADS)

    Gaspard, Pierre

    2016-12-01

    In biology, template-directed copolymerization is the fundamental mechanism responsible for the synthesis of DNA, RNA, and proteins. More than 50 years have passed since the discovery of DNA structure and its role in coding genetic information. Yet, the kinetics and thermodynamics of information processing in DNA replication, transcription, and translation remain poorly understood. Challenging issues are the facts that DNA or RNA sequences constitute disordered media for the motion of polymerases or ribosomes while errors occur in copying the template. Here, it is shown that these issues can be addressed and sequence heterogeneity effects can be quantitatively understood within a framework revealing universal aspects of information processing at the molecular scale. In steady growth regimes, the local velocities of polymerases or ribosomes along the template are distributed as the continuous or fractal invariant set of a so-called iterated function system, which determines the copying error probabilities. The growth may become sublinear in time with a scaling exponent that can also be deduced from the iterated function system.

  12. A VLF-based technique in applications to digital control of nonlinear hybrid multirate systems

    NASA Astrophysics Data System (ADS)

    Vassilyev, Stanislav; Ulyanov, Sergey; Maksimkin, Nikolay

    2017-01-01

    In this paper, a technique for rigorous analysis and design of nonlinear multirate digital control systems on the basis of the reduction method and sublinear vector Lyapunov functions is proposed. The control system model under consideration incorporates continuous-time dynamics of the plant and discrete-time dynamics of the controller and takes into account uncertainties of the plant, bounded disturbances, nonlinear characteristics of sensors and actuators. We consider a class of multirate systems where the control update rate is slower than the measurement sampling rates and periodic non-uniform sampling is admitted. The proposed technique does not use the preliminary discretization of the system, and, hence, allows one to eliminate the errors associated with the discretization and improve the accuracy of analysis. The technique is applied to synthesis of digital controller for a flexible spacecraft in the fine stabilization mode and decentralized controller for a formation of autonomous underwater vehicles. Simulation results are provided to validate the good performance of the designed controllers.

  13. Probing star formation relations of mergers and normal galaxies across the CO ladder

    NASA Astrophysics Data System (ADS)

    Greve, Thomas R.

    We examine integrated luminosity relations between the IR continuum and the CO rotational ladder observed for local (ultra) luminous infra-red galaxies ((U)LIRGs, L IR >= 1011 M⊙) and normal star forming galaxies in the context of radiation pressure regulated star formation proposed by Andrews & Thompson (2011). This can account for the normalization and linear slopes of the luminosity relations (log L IR = α log L'CO + β) of both low- and high-J CO lines observed for normal galaxies. Super-linear slopes occur for galaxy samples with significantly different dense gas fractions. Local (U)LIRGs are observed to have sub-linear high-J (J up > 6) slopes or, equivalently, increasing L COhigh-J /L IR with L IR. In the extreme ISM conditions of local (U)LIRGs, the high-J CO lines no longer trace individual hot spots of star formation (which gave rise to the linear slopes for normal galaxies) but a more widespread warm and dense gas phase mechanically heated by powerful supernovae-driven turbulence and shocks.

  14. Transport properties of elastically coupled fractional Brownian motors

    NASA Astrophysics Data System (ADS)

    Lv, Wangyong; Wang, Huiqi; Lin, Lifeng; Wang, Fei; Zhong, Suchuan

    2015-11-01

    Under the background of anomalous diffusion, which is characterized by the sub-linear or super-linear mean-square displacement in time, we proposed the coupled fractional Brownian motors, in which the asymmetrical periodic potential as ratchet is coupled mutually with elastic springs, and the driving source is the external harmonic force and internal thermal fluctuations. The transport mechanism of coupled particles in the overdamped limit is investigated as the function of the temperature of baths, coupling constant and natural length of the spring, the amplitude and frequency of driving force, and the asymmetry of ratchet potential by numerical stimulations. The results indicate that the damping force involving the information of historical velocity leads to the nonlocal memory property and blocks the traditional dissipative motion behaviors, and it even plays a cooperative role of driving force in drift motion of the coupled particles. Thus, we observe various non-monotonic resonance-like behaviors of collective directed transport in the mediums with different diffusion exponents.

  15. A method of boundary equations for unsteady hyperbolic problems in 3D

    NASA Astrophysics Data System (ADS)

    Petropavlovsky, S.; Tsynkov, S.; Turkel, E.

    2018-07-01

    We consider interior and exterior initial boundary value problems for the three-dimensional wave (d'Alembert) equation. First, we reduce a given problem to an equivalent operator equation with respect to unknown sources defined only at the boundary of the original domain. In doing so, the Huygens' principle enables us to obtain the operator equation in a form that involves only finite and non-increasing pre-history of the solution in time. Next, we discretize the resulting boundary equation and solve it efficiently by the method of difference potentials (MDP). The overall numerical algorithm handles boundaries of general shape using regular structured grids with no deterioration of accuracy. For long simulation times it offers sub-linear complexity with respect to the grid dimension, i.e., is asymptotically cheaper than the cost of a typical explicit scheme. In addition, our algorithm allows one to share the computational cost between multiple similar problems. On multi-processor (multi-core) platforms, it benefits from what can be considered an effective parallelization in time.

  16. Computation of indirect nuclear spin-spin couplings with reduced complexity in pure and hybrid density functional approximations.

    PubMed

    Luenser, Arne; Kussmann, Jörg; Ochsenfeld, Christian

    2016-09-28

    We present a (sub)linear-scaling algorithm to determine indirect nuclear spin-spin coupling constants at the Hartree-Fock and Kohn-Sham density functional levels of theory. Employing efficient integral algorithms and sparse algebra routines, an overall (sub)linear scaling behavior can be obtained for systems with a non-vanishing HOMO-LUMO gap. Calculations on systems with over 1000 atoms and 20 000 basis functions illustrate the performance and accuracy of our reference implementation. Specifically, we demonstrate that linear algebra dominates the runtime of conventional algorithms for 10 000 basis functions and above. Attainable speedups of our method exceed 6 × in total runtime and 10 × in the linear algebra steps for the tested systems. Furthermore, a convergence study of spin-spin couplings of an aminopyrazole peptide upon inclusion of the water environment is presented: using the new method it is shown that large solvent spheres are necessary to converge spin-spin coupling values.

  17. Effect of noni (Morinda citrifolia Linn.) fruit and its bioactive principles scopoletin and rutin on rat vas deferens contractility: an ex vivo study.

    PubMed

    Pandy, Vijayapandi; Narasingam, Megala; Kunasegaran, Thubasni; Murugan, Dharmani Devi; Mohamed, Zahurin

    2014-01-01

    This study examined the effect of methanolic extract of Morinda citrifolia Linn. (MMC) and its bioactive principles, scopoletin and rutin, on dopamine- and noradrenaline-evoked contractility in isolated rat vas deferens preparations. MMC (1-40 mg/mL), scopoletin (1-200 μg/mL), and rutin hydrate (0.6-312.6 μg/mL) dose-dependently inhibited the contractility evoked by submaximal concentrations of both dopamine and noradrenaline, respectively. Haloperidol and prazosin, reference dopamine D2, and α 1-adrenoceptors antagonists significantly reversed the dopamine- and noradrenaline-induced contractions, respectively, in a dose-dependent manner. Interestingly, MMC per se at higher doses (60-100 mg/mL) showed dose-dependent contractile response in rat vas deferens which was partially inhibited by high doses of haloperidol but not by prazosin. These results demonstrated the biphasic effects of MMC on dopaminergic system; that is, antidopaminergic effect at lower concentrations (<40 mg/mL) and dopaminergic agonistic effect at higher concentrations (>60 mg/mL). However, similar contractile response at high doses of scopoletin (0.5-5 mg/mL) and rutin hydrate (0.5-5 mg/mL) per se was not observed. Therefore, it can be concluded that the bioactive principles of MMC, scopoletin, and rutin might be responsible for the antidopaminergic and antiadrenergic activities of MMC.

  18. The degree and nature of radiation damage in zircon observed by 29Si nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Farnan, I.; Salje, E. K. H.

    2001-02-01

    A quantitative analysis of 29Si nuclear magnetic resonance spectra of radiation damaged, natural zircons showed that the local structure in crystalline and amorphous regions depend explicitly on radiation dose. Nonpercolating amorphous islands of high density "glass" within the crystalline matrix show a low interconnectivity of SiO4 tetrahedra. This structural state is quite different from that of the high dose, percolating regions of low density glass with more polymerised tetrahedra. A continuous nonlinear dose dependence between the high and low density glass states is reported. A continuous evolution of the local structure of the crystalline phase up to the percolation point is also reported. No phase separation into binary oxides was observed. The total number of permanently displaced atoms per α-recoil event is ˜3800 atoms for low radiation doses and decreases to ˜2000 atoms for 10×1018 α events/g. No indication of partitioning of paramagnetic impurities between crystalline and amorphous regions was found for these natural zircons. The amorphous fractions of the metamict zircons were determined as a function of their accumulated radiation dose. These values coincide closely with those recently determined by x-ray diffraction studies. They are much greater than previously assumed based on density measurements. The dose dependence is consistent with the concept of direct impact amorphization in the atomic cascade following an α-recoil event.

  19. Characterization of a gated fiber-optic-coupled detector for application in clinical electron beam dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanyi, James A.; Nitzling, Kevin D.; Lodwick, Camille J.

    2011-02-15

    Purpose: Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. Methods: The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and field size. The validity of the detector system's response was assessed in correspondence with a reference ionization chamber. Results: The fiber-optic-coupled dosimetry system showed little dependence to dose rate variations (coefficient of variation {+-}0.37%) and dose per pulse changes (with 0.54% of reference chamber measurements). The reproducibilitymore » of the system was {+-}0.55% for dose fractions of {approx}100 cGy. Energy dependence was within {+-}1.67% relative to the reference ionization chamber for the 6-20 MeV nominal electron beam energy range. The system exhibited excellent linear response (R{sup 2}=1.000) compared to reference ionization chamber in the dose range of 1-1000 cGy. The output factors were within {+-}0.54% of the corresponding reference ionization chamber measurements. Conclusions: The dosimetric properties of the gated fiber-optic-coupled dosimetry system compare favorably to the corresponding reference ionization chamber measurements and show considerable potential for applications in clinical electron beam radiotherapy.« less

  20. PTW-diamond detector: dose rate and particle type dependence.

    PubMed

    Fidanzio, A; Azario, L; Miceli, R; Russo, A; Piermattei, A

    2000-11-01

    In this paper the suitability of a PTW natural diamond detector (DD) for relative and reference dosimetry of photon and electron beams, with dose per pulse between 0.068 mGy and 0.472 mGy, was studied and the results were compared with those obtained by a stereotactic silicon detector (SFD). The results show that, in the range of the examined dose per pulse the DD sensitivity changes up to 1.8% while the SFD sensitivity changes up to 4.5%. The fitting parameter, delta, used to correct the dose per pulse dependence of solid state detectors, was delta = 0.993 +/- 0.002 and delta = 1.025 +/- 0.002 for the diamond detector and for the silicon diode, respectively. The delta values were found to be independent of particle type of two conventional beams (a 10 MV x-ray beam and a 21 MeV electron beam). So if delta is determined for a radiotherapy beam, it can be used to correct relative dosimetry for other conventional radiotherapy beams. Moreover the diamond detector shows a calibration factor which is independent of beam quality and particle type, so an empirical dosimetric formalism is proposed here to obtain the reference dosimetry. This formalism is based on a dose-to-water calibration factor and on an empirical coefficient, that takes into account the reading dependence on the dose per pulse.

  1. Caffeine as a model drug of dependence: recent developments in understanding caffeine withdrawal, the caffeine dependence syndrome, and caffeine negative reinforcement.

    PubMed

    Griffiths, R R; Chausmer, A L

    2000-11-01

    Caffeine is an excellent model compound for understanding drugs of abuse/dependence. The results of self-administration and choice studies in humans clearly demonstrate the reinforcing effects of low and moderate doses of caffeine. Caffeine reinforcement has been demonstrated in about 45% of normal subjects with histories of moderate and heavy caffeine use. Recent studies provide compelling evidence that caffeine physical dependence potentiates the reinforcing effects of caffeine through the mechanism of withdrawal symptom avoidance. Tolerance to the subjective and sleep-disrupting effects of caffeine in humans has been demonstrated. Physical dependence as reflected in a withdrawal syndrome in humans has been repeatedly demonstrated in adults and recently demonstrated in children. Withdrawal severity is an increasing function of caffeine maintenance dose, with withdrawal occurring at doses as low as 100 mg per day. Increased cerebral blood flow may be the physiological mechanism for caffeine withdrawal headache. Case studies in adults and adolescents clearly demonstrate that some individuals meet DSM-IV diagnostic criteria for a substance dependence syndrome on caffeine, including feeling compelled to continue caffeine use despite desires and recommendations to the contrary. Survey data suggest that 9% to 30% percent of caffeine consumers may be caffeine dependent according to DSM-IV criteria.

  2. Behavioral and growth effects induced by low dose methamphetamine administration during the neonatal period in rats

    PubMed Central

    Williams, Michael T.; Moran, Mary S.; Vorhees, Charles V.

    2009-01-01

    The investigation of methamphetamine exposure during neonatal development in rats has demonstrated that long-term spatial learning deficits are induced. A previous dose–response study showed that administration of 5 mg/kg methamphetamine, four times daily from postnatal days 11 to 20 produced these deficits, although the effects were not as severe as at higher doses of 10 or 15 mg/kg. This study examined concentrations of methamphetamine at or below 5 mg/kg given over the same period of time. Five different concentrations of methamphetamine (i.e., 5, 2.5, 1.25, 0.625, or 0) were administered every 2 h four times daily from postnatal days 11 to 20. Body weights, zero maze performance, and Morris water maze learning were examined. A dose-dependent decrease in body weight was observed during the period of methamphetamine administration and these lower weights continued throughout adulthood for the 5, 2.5, and 1.25 mg/kg concentrations, although the adult decreases were negligible. No differences were noted in the zero maze. In the Morris water maze during the acquisition period, dose-dependent differences in spatial orientation were seen, however non-dose related deficits were observed for other parameters. During the shifted platform phase (“reversal”), a similar dose-dependent difference in spatial orientation was observed, although no other effects were noted during this phase. Females performed worse than males regardless of treatment or the phase of learning in the Morris water maze. These data suggest that even lower doses of methamphetamine can alter learning and memory in adulthood, although with less consistent results than with doses higher than 5 mg/kg/dose. These data would caution against even casual use of methamphetamine by women during pregnancy since even low doses could alter the ability of the child to learn. PMID:15380827

  3. Prevalence of bisphosphonate-related osteonecrosis of the jaw-like lesions is increased in a chemotherapeutic dose-dependent manner in mice.

    PubMed

    Kuroshima, Shinichiro; Sasaki, Muneteru; Nakajima, Kazunori; Tamaki, Saki; Hayano, Hiroki; Sawase, Takashi

    2018-07-01

    Bisphosphonate-related osteonecrosis of the jaw (BRONJ) worsens oral health-related quality of life. Most BRONJ occurs in multiple myeloma or metastatic breast cancer patients treated with bisphosphonate/chemotherapeutic combination therapies. Cyclophosphamide (CY), an alkylating chemotherapeutic drug, is used to treat multiple myeloma, although its use has been recently reduced. The aim of this study was to clarify the effects of CY dose on tooth extraction socket healing when CY is used with or without bisphosphonate in mice. Low-dose CY (50 mg/kg; CY-L), moderate-dose CY (100 mg/kg; CY-M), high-dose CY (150 mg/kg; CY-H), and bisphosphonate [Zometa (ZA): 0.05 mg/kg] were administered for 7 weeks. Each dose of CY and ZA in combination was also administered for 7 weeks. Both maxillary first molars were extracted at 3 weeks after the initiation of drug administration. Euthanasia was performed at 4 weeks post-extraction. Gross wound healing, microcomputed tomography analysis, histomorphometry, and immunohistochemistry were used to quantitatively evaluate osseous and soft tissue wound healing of tooth extraction sockets. ZA monotherapy induced no BRONJ-like lesions in mice. CY monotherapy rarely induced open wounds, though delayed osseous wound healing occurred in a CY dose-dependent manner. In contrast, CY/ZA combination therapy prevalently induced BRONJ-like lesions with compromised osseous and soft tissue healing in a CY dose-dependent manner. Interestingly, anti-angiogenesis was noted regardless of CY dose and ZA administration, even though only CY-M/ZA and CY-H/ZA combination therapies induced BRONJ-like lesions. Our findings suggest that high-dose CY may be associated with the development of BRONJ following tooth extraction only when CY is used together with ZA. In addition to anti-angiogenesis, other factors may contribute to the pathoetiology of BRONJ. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. 42 CFR 82.2 - What are the basics of dose reconstruction?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... this exposure environment. Then methods are applied to translate exposure to radiation into quantified... workers. A hierarchy of methods is used in a dose reconstruction, depending on the nature of the exposure...

  5. 42 CFR 82.2 - What are the basics of dose reconstruction?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... this exposure environment. Then methods are applied to translate exposure to radiation into quantified... workers. A hierarchy of methods is used in a dose reconstruction, depending on the nature of the exposure...

  6. Dose-dependent high-resolution electron ptychography

    NASA Astrophysics Data System (ADS)

    D'Alfonso, A. J.; Allen, L. J.; Sawada, H.; Kirkland, A. I.

    2016-02-01

    Recent reports of electron ptychography at atomic resolution have ushered in a new era of coherent diffractive imaging in the context of electron microscopy. We report and discuss electron ptychography under variable electron dose conditions, exploring the prospects of an approach which has considerable potential for imaging where low dose is needed.

  7. MODELING THE INTERACTION THRESHOLD: THE BREAK-POINT BETWEEN ADDITIVITY AND NON-ADDITIVITY

    EPA Science Inventory

    Dose-dependent changes in toxicity mechanisms of single chemicals may take place along the full dose-response spectrum. At high doses, the possibility exists for some steps in the principle mechanism of toxicity to shift to other mechanisms. The possibility of mechanism shifts fo...

  8. Total Ionizing Dose Effects in Bipolar and BiCMOS Devices

    NASA Technical Reports Server (NTRS)

    Chavez, Rosa M.; Rax, Bernard G.; Scheick, Leif Z.; Johnston, Allan H.

    2005-01-01

    This paper describes total ionizing dose (TID) test results performed at JPL. Bipolar and BiCMOS device samples were tested exhibiting significant degradation and failures at different irradiation levels. Linear technology which is susceptible to low-dose dependency (ELDRS) exhibited greater damage for devices tested under zero bias condition.

  9. A novel synthetic single crystal diamond device for in vivo dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marinelli, Marco; Prestopino, G., E-mail: giuseppe.prestopino@uniroma2.it; Tonnetti, A.

    Purpose: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of “Tor Vergata” University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. Methods: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application wasmore » performed under irradiation with {sup 60}Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. Results: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. Conclusions: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.« less

  10. Transient impairment of hippocampus-dependent learning and memory in relatively low-dose of acute radiation syndrome is associated with inhibition of hippocampal neurogenesis.

    PubMed

    Kim, Joong-Sun; Lee, Hae-June; Kim, Jong Choon; Kang, Seong Soo; Bae, Chun-Sik; Shin, Taekyun; Jin, Jae-Kwang; Kim, Sung Ho; Wang, Hongbing; Moon, Changjong

    2008-09-01

    Neurogenesis in the adult hippocampus, which occurs constitutively, is vulnerable to ionizing radiation. In the relatively low-dose exposure of acute radiation syndrome (ARS), the change in the adult hippocampal function is poorly understood. This study analyzed the changes in apoptotic cell death and neurogenesis in the DGs of hippocampi from adult ICR mice with single whole-body gamma-irradiation using the TUNEL method and immunohistochemical markers of neurogenesis, Ki-67 and doublecortin (DCX). In addition, the hippocampus-dependent learning and memory tasks after single whole-body gamma-irradiation were examined in order to evaluate the hippocampus-related behavioral dysfunction in the relatively low-dose exposure of ARS. The number of TUNEL-positive apoptotic nuclei in the dentate gyrus (DG) was increased 6-12 h after acute gamma-irradiation (a single dose of 0.5 to 4 Gy). In contrast, the number of Ki-67- and DCX-positive cells began to decrease significantly 6 h postirradiation, reaching its lowest level 24 h after irradiation. The level of Ki-67 and DCX immunoreactivity decreased in a dose-dependent manner within the range of irradiation applied (0-4 Gy). In passive avoidance and object recognition memory test, the mice trained 1 day after acute irradiation (2 Gy) showed significant memory deficits, compared with the sham controls. In conclusion, the pattern of the hippocampus-dependent memory dysfunction is consistent with the change in neurogenesis after acute irradiation. It is suggested that a relatively low dose of ARS in adult ICR mice is sufficiently detrimental to interrupt the functioning of the hippocampus, including learning and memory, possibly through the inhibition of neurogenesis.

  11. 3,3′,4,4′,5-Pentachlorobiphenyl (PCB 126) Decreases Hepatic and Systemic Ratios of Epoxide to Diol Metabolites of Unsaturated Fatty Acids in Male Rats

    PubMed Central

    Wu, Xianai; Yang, Jun; Morisseau, Christophe; Robertson, Larry W.; Hammock, Bruce; Lehmler, Hans-Joachim

    2016-01-01

    Disruption of the homeostasis of oxygenated regulatory lipid mediators (oxylipins), potential markers of exposure to aryl hydrocarbon receptor (AhR) agonists, such as 3,3′,4,4′,5-pentachlorobiphenyl (PCB 126), is associated with a range of diseases, including nonalcoholic fatty liver disease and nonalcoholic steatohepatitis. Here we test the hypothesis that PCB 126 exposure alters the levels of oxylipins in rats. Male Sprague-Dawley rats (5-weeks old) were treated over a 3-month period every 2 weeks with intraperitoneal injections of PCB 126 in corn oil (cumulative doses of 0, 19.8, 97.8, and 390 µg/kg b.w.; 6 injections total). PCB 126 treatment caused a reduction in growth rates at the highest dose investigated, a dose-dependent decrease in thymus weights, and a dose-dependent increase in liver weights. Liver PCB 126 levels increased in a dose-dependent manner, while levels in plasma were below or close to the detection limit. The ratios of several epoxides to diol metabolites formed via the cytochrome P450 (P450) monooxygenase/soluble epoxide hydrolase (sEH) pathway from polyunsaturated fatty acids displayed a dose-dependent decrease in the liver and plasma, whereas levels of oxylipins formed by other metabolic pathways were generally not altered by PCB 126 treatment. The effects of PCB 126 on epoxide-to-diol ratios were associated with an increased CYP1A activity in liver microsomes and an increased sEH activity in liver cytosol and peroxisomes. These results suggest that oxylipins are potential biomarkers of exposure to PCB 126 and that the P450/sEH pathway is a therapeutic target for PCB 126-mediated hepatotoxicity that warrants further attention. PMID:27208083

  12. A novel synthetic single crystal diamond device for in vivo dosimetry.

    PubMed

    Marinelli, Marco; Prestopino, G; Tonnetti, A; Verona, C; Verona-Rinati, G; Falco, M D; Bagalà, P; Pimpinella, M; Guerra, A S; De Coste, V

    2015-08-01

    Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of "Tor Vergata" University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with (60)Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.

  13. Dissipation and adsorption of isoproturon, tebuconazole, chlorpyrifos and their main transformation products under laboratory and field conditions.

    PubMed

    Papadopoulou, Evangelia S; Karas, Panagiotis A; Nikolaki, Sofia; Storck, Veronika; Ferrari, Federico; Trevisan, Marco; Tsiamis, George; Martin-Laurent, Fabrice; Karpouzas, Dimitrios G

    2016-11-01

    Assessment of dissipation constitutes an integral part of pesticides risk assessment since it provides an estimate of the level and the duration of exposure of the terrestrial ecosystem to pesticides. Within the frame of an overall assessment of the soil microbial toxicity of pesticides, we investigated the dissipation of a range of dose rates of three model pesticides, isoproturon (IPU), tebuconazole (TCZ), and chlorpyrifos (CHL), and the formation and dissipation of their main transformation products following a tiered lab-to-field approach. The adsorption of pesticides and their transformation products was also determined. IPU was the least persistent pesticide showing a dose-dependent increase in its persistence in both laboratory and field studies. CHL dissipation showed a dose-dependent increase under laboratory conditions and an exact opposite trend in the field. TCZ was the most persistent pesticide under lab conditions showing a dose-dependent decrease in its dissipation, whereas in the field TCZ exhibited a biphasic dissipation pattern with extrapolated DT90s ranging from 198 to 603.4days in the ×1 and ×2 dose rates, respectively. IPU was demethylated to mono- (MD-IPU) and di-desmethyl-isoproturon (DD-IPU) which dissipated following a similar pattern with the parent compound. CHL was hydrolyzed to 3,5,6-trichloro-2-pyridinol (TCP) which dissipated showing a reverse dose-dependent pattern compared to CHL. Pesticides adsorption affinity increased in the order IPU

  14. Exposure to low UVA doses increases KatA and KatB catalase activities, and confers cross-protection against subsequent oxidative injuries in Pseudomonas aeruginosa.

    PubMed

    Pezzoni, Magdalena; Tribelli, Paula M; Pizarro, Ramón A; López, Nancy I; Costa, Cristina S

    2016-05-01

    Solar UVA radiation is one of the main environmental stress factors for Pseudomonas aeruginosa. Exposure to high UVA doses produces lethal effects by the action of the reactive oxygen species (ROS) it generates. P. aeruginosa has several enzymes, including KatA and KatB catalases, which provide detoxification of ROS. We have previously demonstrated that KatA is essential in defending P. aeruginosa against high UVA doses. In order to analyse the mechanisms involved in the adaptation of this micro-organism to UVA, we investigated the effect of exposure to low UVA doses on KatA and KatB activities, and the physiological consequences. Exposure to UVA induced total catalase activity; assays with non-denaturing polyacrylamide gels showed that both KatA and KatB activities were increased by radiation. This regulation occurred at the transcriptional level and depended, at least partly, on the increase in H2O2 levels. We demonstrated that exposure to low UVA produced a protective effect against subsequent lethal doses of UVA, sodium hypochlorite and H2O2. Protection against lethal UVA depends on katA, whilst protection against sodium hypochlorite depends on katB, demonstrating that different mechanisms are involved in the defence against these oxidative agents, although both genes can be involved in the global cellular response. Conversely, protection against lethal doses of H2O2 could depend on induction of both genes and/or (an)other defensive factor(s). A better understanding of the adaptive response of P. aeruginosa to UVA is relevant from an ecological standpoint and for improving disinfection strategies that employ UVA or solar irradiation.

  15. Erysodine, a competitive antagonist at neuronal nicotinic acetylcholine receptors, decreases ethanol consumption in alcohol-preferring UChB rats.

    PubMed

    Quiroz, Gabriel; Guerra-Díaz, Nicolás; Iturriaga-Vásquez, Patricio; Rivera-Meza, Mario; Quintanilla, María Elena; Sotomayor-Zárate, Ramón

    2018-09-03

    Alcohol abuse is a worldwide health problem with high economic costs to health systems. Emerging evidence suggests that modulation of brain nicotinic acetylcholine receptors (nAChRs) may be a therapeutic target for alcohol dependence. In this work, we assess the effectiveness of four doses of erysodine (1.5, 2.0, 4.0 or 8.0 mg/kg/day, i.p.), a competitive antagonist of nAChRs, on voluntary ethanol consumption behavior in alcohol-preferring UChB rats, administered during three consecutive days. Results show that erysodine administration produces a dose-dependent reduction in ethanol consumption respect to saline injection (control group). The highest doses of erysodine (4 and 8 mg/kg) reduce (45 and 66%, respectively) the ethanol intake during treatment period and first day of post-treatment compared to control group. While, the lowest doses of erysodine (1.5 and 2 mg/kg) only reduce ethanol intake during one day of treatment period. These effective reductions in ethanol intake were 23 and 29% for 1.5 and 2 mg/kg erysodine, respectively. Locomotor activity induced by a high dose of erysodine (10 mg/kg) was similar to those observed with saline injection in control rats, showing that the reduction in ethanol intake was not produced by hypolocomotor effect induced by erysodine. This is the first report showing that erysodine reduces ethanol intake in UChB rats in a dose-dependent manner. Our results highlight the role of nAChRs in the reward effects of ethanol and its modulation as a potentially effective pharmacological alternative for alcohol dependence treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Dose Relations between Goal Setting, Theory-Based Correlates of Goal Setting and Increases in Physical Activity during a Workplace Trial

    ERIC Educational Resources Information Center

    Dishman, Rod K.; Vandenberg, Robert J.; Motl, Robert W.; Wilson, Mark G.; DeJoy, David M.

    2010-01-01

    The effectiveness of an intervention depends on its dose and on moderators of dose, which usually are not studied. The purpose of the study is to determine whether goal setting and theory-based moderators of goal setting had dose relations with increases in goal-related physical activity during a successful workplace intervention. A…

  17. Dose- and time-dependence of the host-mediated response to paclitaxel therapy: a mathematical modeling approach.

    PubMed

    Benguigui, Madeleine; Alishekevitz, Dror; Timaner, Michael; Shechter, Dvir; Raviv, Ziv; Benzekry, Sebastien; Shaked, Yuval

    2018-01-05

    It has recently been suggested that pro-tumorigenic host-mediated processes induced in response to chemotherapy counteract the anti-tumor activity of therapy, and thereby decrease net therapeutic outcome. Here we use experimental data to formulate a mathematical model describing the host response to different doses of paclitaxel (PTX) chemotherapy as well as the duration of the response. Three previously described host-mediated effects are used as readouts for the host response to therapy. These include the levels of circulating endothelial progenitor cells in peripheral blood and the effect of plasma derived from PTX-treated mice on migratory and invasive properties of tumor cells in vitro . A first set of mathematical models, based on basic principles of pharmacokinetics/pharmacodynamics, did not appropriately describe the dose-dependence and duration of the host response regarding the effects on invasion. We therefore provide an alternative mathematical model with a dose-dependent threshold, instead of a concentration-dependent one, that describes better the data. This model is integrated into a global model defining all three host-mediated effects. It not only precisely describes the data, but also correctly predicts host-mediated effects at different doses as well as the duration of the host response. This mathematical model may serve as a tool to predict the host response to chemotherapy in cancer patients, and therefore may be used to design chemotherapy regimens with improved therapeutic outcome by minimizing host mediated effects.

  18. Beam energy considerations for gold nano-particle enhanced radiation treatment.

    PubMed

    Van den Heuvel, F; Locquet, Jean-Pierre; Nuyts, S

    2010-08-21

    A novel approach using nano-technology enhanced radiation modalities is investigated. The proposed methodology uses antibodies labeled with organically inert metals with a high atomic number. Irradiation using photons with energies in the kilo-electron volt (keV) range shows an increase in dose due to a combination of an increase in photo-electric interactions and a pronounced generation of Auger and/or Coster-Krönig (A-CK) electrons. The dependence of the dose deposition on various factors is investigated using Monte Carlo simulation models. The factors investigated include agent concentration, spectral dependence looking at mono-energetic sources as well as classical bremsstrahlung sources. The optimization of the energy spectrum is performed in terms of physical dose enhancement as well as the dose deposited by Auger and/or Coster-Krönig electrons and their biological effectiveness. A quasi-linear dependence on concentration and an exponential decrease within the target medium is observed. The maximal dose enhancement is dependent on the position of the target in the beam. Apart from irradiation with low-photon energies (10-20 keV) there is no added benefit from the increase in generation of Auger electrons. Interestingly, a regular 110 kVp bremsstrahlung spectrum shows a comparable enhancement in comparison with the optimized mono-energetic sources. In conclusion we find that the use of enhanced nano-particles shows promise to be implemented quite easily in regular clinics on a physical level due to the advantageous properties in classical beams.

  19. Beam energy considerations for gold nano-particle enhanced radiation treatment

    NASA Astrophysics Data System (ADS)

    Van den Heuvel, F.; Locquet, Jean-Pierre; Nuyts, S.

    2010-08-01

    A novel approach using nano-technology enhanced radiation modalities is investigated. The proposed methodology uses antibodies labeled with organically inert metals with a high atomic number. Irradiation using photons with energies in the kilo-electron volt (keV) range shows an increase in dose due to a combination of an increase in photo-electric interactions and a pronounced generation of Auger and/or Coster-Krönig (A-CK) electrons. The dependence of the dose deposition on various factors is investigated using Monte Carlo simulation models. The factors investigated include agent concentration, spectral dependence looking at mono-energetic sources as well as classical bremsstrahlung sources. The optimization of the energy spectrum is performed in terms of physical dose enhancement as well as the dose deposited by Auger and/or Coster-Krönig electrons and their biological effectiveness. A quasi-linear dependence on concentration and an exponential decrease within the target medium is observed. The maximal dose enhancement is dependent on the position of the target in the beam. Apart from irradiation with low-photon energies (10-20 keV) there is no added benefit from the increase in generation of Auger electrons. Interestingly, a regular 110 kVp bremsstrahlung spectrum shows a comparable enhancement in comparison with the optimized mono-energetic sources. In conclusion we find that the use of enhanced nano-particles shows promise to be implemented quite easily in regular clinics on a physical level due to the advantageous properties in classical beams.

  20. Dose-dependent effects of wheel running on cocaine-seeking and prefrontal cortex Bdnf exon IV expression in rats.

    PubMed

    Peterson, Alexis B; Abel, Jean M; Lynch, Wendy J

    2014-04-01

    Physical activity, and specifically exercise, has shown promise as an intervention for drug addiction; however, the exercise conditions that produce the most efficacious response, as well as its underlying mechanism, are unknown. In this study, we examined the dose-dependent effects of wheel running, an animal model of exercise, during abstinence on subsequent cocaine-seeking and associated changes in prefrontal cortex (PFC) brain-derived neurotrophic factor (Bdnf) exon IV expression, a marker of epigenetic regulation implicated in cocaine relapse and known to be regulated by exercise. Cocaine-seeking was assessed under a within-session extinction/cue-induced reinstatement procedure following extended access cocaine or saline self-administration (24-h/day, 4 discrete trials/h, 10 days, 1.5 mg/kg/infusion) and a 14-day abstinence period. During abstinence, rats had either locked or unlocked running wheel access for 1, 2, or 6 h/day. Bdnf exon IV expression was assessed using quantitative real-time polymerase chain reaction. Cocaine-seeking was highest under the locked wheel condition, and wheel running dose dependently attenuated this effect. Cocaine increased Bdnf exon IV expression, and wheel running dose dependently attenuated this increase, with complete blockade in rats given 6-h/day access. Notably, the efficacy of exercise was inversely associated with Bdnf exon IV expression, and both its efficacy and its effects on Bdnf exon IV expression were mimicked by treatment during abstinence with sodium butyrate, a histone deacetylase inhibitor that, like exercise, modulates gene transcription, including Bdnf exon IV expression. Taken together, these results indicate that the efficacy of exercise is dose dependent and likely mediated through epigenetic regulation of PFC Bdnf.

  1. Bedtime Routines for Young Children: A Dose-Dependent Association with Sleep Outcomes

    PubMed Central

    Mindell, Jodi A.; Li, Albert M.; Sadeh, Avi; Kwon, Robert; Goh, Daniel Y.T.

    2015-01-01

    Background: Establishment of a consistent bedtime routine (the activities that occur right before lights out) is often recommended as part of healthy sleep habits. However, no studies have investigated the dose-dependent association of a bedtime routine with sleep outcomes, especially in young children for whom they are particularly recommended. Thus, the aim of this study was to examine the associations of a consistent bedtime routine with sleep outcomes in young children (ages 0 through 5 y) in a large global sample and assess whether there is a dose-dependent relationship between the frequency of a bedtime routine both concurrently and retrospectively with sleep outcomes. Participants: Mothers of 10,085 children (Australia-New Zealand, Canada, China, Hong Kong, India, Japan, Korea, Malaysia, Philippines, Singapore, Thailand, United Kingdom, United States) completed the Brief Infant/Child Sleep Questionnaire. Results: A consistent bedtime routine was associated with better sleep outcomes, including earlier bedtimes, shorter sleep onset latency, reduced night wakings, and increased sleep duration. Decreased parent-perceived sleep problems and daytime behavior problems were also related to institution of a regular bedtime routine. Furthermore, there was a dose-dependent relationship, with better outcomes associated with increased “doses” of having a bedtime routine, both currently and retrospectively, and was found within both predominantly Asian and predominantly Caucasian cultural regions. Conclusions: These results indicate that having a regular nightly bedtime routine is associated with improved sleep in young children, and suggests that the more consistently a bedtime routine is instituted and the younger started the better. Citation: Mindell JA, Li AM, Sadeh A, Kwon R, Goh DY. Bedtime routines for young children: a dose-dependent association with sleep outcomes. SLEEP 2015;38(5):717–722. PMID:25325483

  2. ABCB1 genetic variability and methadone dosage requirements in opioid-dependent individuals.

    PubMed

    Coller, Janet K; Barratt, Daniel T; Dahlen, Karianne; Loennechen, Morten H; Somogyi, Andrew A

    2006-12-01

    The most common treatment for opioid dependence is substitution therapy with another opioid such as methadone. The methadone dosage is individualized but highly variable, and program retention rates are low due in part to nonoptimal dosing resulting in withdrawal symptoms and further heroin craving and use. Methadone is a substrate for the P-glycoprotein transporter, encoded by the ABCB1 gene, which regulates central nervous system exposure. This retrospective study aimed to investigate the influence of ABCB1 genetic variability on methadone dose requirements. Genomic deoxyribonucleic acid was isolated from opioid-dependent subjects (n = 60) and non-opioid-dependent control subjects (n = 60), and polymerase chain reaction-restriction fragment length polymorphism and allele-specific polymerase chain reaction were used to determine the presence of single nucleotide polymorphisms at positions 61, 1199, 1236, 2677, and 3435. ABCB1 haplotypes were inferred with PHASE software (version 2.1). There were no significant differences in the allele or genotype frequencies of the individual single nucleotide polymorphisms or haplotypes between the 2 populations. ABCB1 genetic variability influenced daily methadone dose requirements, such that subjects carrying 2 copies of the wild-type haplotype required higher doses compared with those with 1 copy and those with no copies (98.3 +/- 10.4, 58.6 +/- 20.9, and 55.4 +/- 26.1 mg/d, respectively; P = .029). In addition, carriers of the AGCTT haplotype required significantly lower doses than noncarriers (38.0 +/- 16.8 and 61.3 +/- 24.6 mg/d, respectively; P = .04). Although ABCB1 genetic variability is not related to the development of opioid dependence, identification of variant haplotypes may, after larger prospective studies have been performed, provide clinicians with a tool for methadone dosage individualization.

  3. Impact of the Nationwide Intravenous Selenium Product Shortage on the Development of Selenium Deficiency in Infants Dependent on Long-Term Parenteral Nutrition.

    PubMed

    Chen, Connie H; Harris, Mary Beth; Partipilo, M Luisa; Welch, Kathleen B; Teitelbaum, Daniel H; Blackmer, Allison B

    2016-08-01

    For patients dependent on parenteral nutrition (PN), selenium must be supplemented intravenously. A nationwide intravenous selenium shortage began in April 2011. The impact of this shortage on PN-dependent infants was evaluated by examining the provision of selenium, development of biochemical deficiency, and costs associated with the shortage. This single-center, retrospective study included PN-dependent infants aged ≤1 year who weighed ≤30 kg, received PN for ≥1 month, and had ≥1 serum selenium measurement. The primary outcome was the incidence of biochemical selenium deficiency. Secondary outcomes included severity of biochemical deficiency, clinical manifestations, costs, and relationship between serum selenium levels and selenium dose. The average selenium dose decreased 2-fold during the shortage (2.1 ± 1.2 µg/kg/d; range, 0.2-4.6 µg/kg/d) versus the nonshortage period (3.8 ± 1 µg/kg/d; range, 2.4-6 µg/kg/d; P < .001). A linear relationship between serum selenium concentration and selenium dose was observed (r(2) = 0.42), with a dose of 6 µg/kg/d expected to result in normal serum levels in most cases. Similar proportions of patients developed biochemical deficiency in both groups: shortage period, 59.1%; nonshortage, 66.7%; P = .13. The severity of biochemical deficiency was similar between groups. A significant increase in incremental cost during the shortage was observed. This is the first study examining the impact of the intravenous selenium shortage on PN-dependent infants. Both groups exhibited similarly high incidences of biochemical selenium deficiency, suggesting higher empiric doses may benefit this population. However, ongoing shortages limit the ability to provide supplementation. © 2015 American Society for Parenteral and Enteral Nutrition.

  4. Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonovic, Laura; Gustafsson, Haakan; Alm Carlsson, Gudrun

    2009-06-15

    A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantommore » were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.« less

  5. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    NASA Astrophysics Data System (ADS)

    Paiva Fonseca, Gabriel; Carlsson Tedgren, Åsa; Reniers, Brigitte; Nilsson, Josef; Persson, Maria; Yoriyaz, Hélio; Verhaegen, Frank

    2015-06-01

    Dose calculation in high dose rate brachytherapy with 192Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (Dm,m) and dose-to-water-in-medium (Dw,m). The relation between Dm,m and Dw,m for 192Ir is the main goal of this study, in particular the dependence of Dw,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: Dm,m, Dw,m (LCT), mean photon energy and photon fluence. Dw,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between Dm,m and Dw,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between Dw,m (SCT) and Dw,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between Dm,m and Dw,m (SCT) mainly depend on tissue type, differences between Dm,m and Dw,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources.

  6. Pharmacokinetics of testosterone cream applied to scrotal skin.

    PubMed

    Iyer, R; Mok, S F; Savkovic, S; Turner, L; Fraser, G; Desai, R; Jayadev, V; Conway, A J; Handelsman, D J

    2017-07-01

    Scrotal skin is thin and has high steroid permeability, but the pharmacokinetics of testosterone via the scrotal skin route has not been studied in detail. The aim of this study was to define the pharmacokinetics of testosterone delivered via the scrotal skin route. The study was a single-center, three-phase cross-over pharmacokinetic study of three single doses (12.5, 25, 50 mg) of testosterone cream administered in random sequence on different days with at least 2 days between doses to healthy eugonadal volunteers with endogenous testosterone suppressed by administration of nandrolone decanoate. Serum testosterone, DHT and estradiol concentrations were measured by liquid chromatograpy, mass spectrometry in extracts of serum taken before and for 16 h after administration of each of the three doses of testosterone cream to the scrotal skin. Testosterone administration onto the scrotal skin produced a swift (peak 1.9-2.8 h), dose-dependent (p < 0.0001) increase in serum testosterone with the 25 mg dose maintaining physiological levels for 16 h. Serum DHT displayed a time- (p < 0.0001), but not dose-dependent, increase in concentration reaching a peak concentration of 1.2 ng/mL (4.1 nm) at 4.9 h which was delayed by 2 h after peak serum testosterone. There were no significant changes in serum estradiol over time after testosterone administration. We conclude that testosterone administration to scrotal skin is well tolerated and produces dose-dependent peak serum testosterone concentration with a much lower dose relative to the non-scrotal transdermal route. © 2017 American Society of Andrology and European Academy of Andrology.

  7. Dependences of mucosal dose on photon beams in head-and-neck intensity-modulated radiation therapy: a Monte Carlo study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chow, James C.L., E-mail: james.chow@rmp.uhn.on.ca; Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Department of Physics, Ryerson University, Toronto, Ontario

    2012-07-01

    Dependences of mucosal dose in the oral or nasal cavity on the beam energy, beam angle, multibeam configuration, and mucosal thickness were studied for small photon fields using Monte Carlo simulations (EGSnrc-based code), which were validated by measurements. Cylindrical mucosa phantoms (mucosal thickness = 1, 2, and 3 mm) with and without the bone and air inhomogeneities were irradiated by the 6- and 18-MV photon beams (field size = 1 Multiplication-Sign 1 cm{sup 2}) with gantry angles equal to 0 Degree-Sign , 90 Degree-Sign , and 180 Degree-Sign , and multibeam configurations using 2, 4, and 8 photon beams inmore » different orientations around the phantom. Doses along the central beam axis in the mucosal tissue were calculated. The mucosal surface doses were found to decrease slightly (1% for the 6-MV photon beam and 3% for the 18-MV beam) with an increase of mucosal thickness from 1-3 mm, when the beam angle is 0 Degree-Sign . The variation of mucosal surface dose with its thickness became insignificant when the beam angle was changed to 180 Degree-Sign , but the dose at the bone-mucosa interface was found to increase (28% for the 6-MV photon beam and 20% for the 18-MV beam) with the mucosal thickness. For different multibeam configurations, the dependence of mucosal dose on its thickness became insignificant when the number of photon beams around the mucosal tissue was increased. The mucosal dose with bone was varied with the beam energy, beam angle, multibeam configuration and mucosal thickness for a small segmental photon field. These dosimetric variations are important to consider improving the treatment strategy, so the mucosal complications in head-and-neck intensity-modulated radiation therapy can be minimized.« less

  8. Relative Biological Effectiveness of HZE Particles for Chromosomal Exchanges and Other Surrogate Cancer Risk Endpoints.

    PubMed

    Cacao, Eliedonna; Hada, Megumi; Saganti, Premkumar B; George, Kerry A; Cucinotta, Francis A

    2016-01-01

    The biological effects of high charge and energy (HZE) particle exposures are of interest in space radiation protection of astronauts and cosmonauts, and estimating secondary cancer risks for patients undergoing Hadron therapy for primary cancers. The large number of particles types and energies that makeup primary or secondary radiation in HZE particle exposures precludes tumor induction studies in animal models for all but a few particle types and energies, thus leading to the use of surrogate endpoints to investigate the details of the radiation quality dependence of relative biological effectiveness (RBE) factors. In this report we make detailed RBE predictions of the charge number and energy dependence of RBE's using a parametric track structure model to represent experimental results for the low dose response for chromosomal exchanges in normal human lymphocyte and fibroblast cells with comparison to published data for neoplastic transformation and gene mutation. RBE's are evaluated against acute doses of γ-rays for doses near 1 Gy. Models that assume linear or non-targeted effects at low dose are considered. Modest values of RBE (<10) are found for simple exchanges using a linear dose response model, however in the non-targeted effects model for fibroblast cells large RBE values (>10) are predicted at low doses <0.1 Gy. The radiation quality dependence of RBE's against the effects of acute doses γ-rays found for neoplastic transformation and gene mutation studies are similar to those found for simple exchanges if a linear response is assumed at low HZE particle doses. Comparisons of the resulting model parameters to those used in the NASA radiation quality factor function are discussed.

  9. Radiation Pneumopathy in the Rat After Intravenous Application of {sup 188}Re-Labeled Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liepe, Knut; Faulhaber, Diana; Wunderlich, Gerd

    2011-10-01

    Purpose: To determine the dose dependence and kinetics of pneumopathy after systemic administration of rhenium-188 ({sup 188}Re)-labeled microspheres in a rat model. Methods and Materials: {sup 188}Re-microspheres were injected intravenously into adult Wistar rats (n = 54, age, 8 {+-} 2 months). The rats were divided into 6 groups according to the intended absorbed dose in the lung (maximum 60 Gy). Gamma camera scans were used to estimate the individual whole lung doses. One control group (n = 5) received nonlabeled microspheres. The breathing rate was measured before and weekly after the treatment using whole body plethysmography until 24 weeks.more » An increase in the breathing rate by 20% compared with the individual pretreatment control value was defined as the quantal endpoint for dose-effect analyses. Results: A biphasic increase in the breathing rate was observed. The first impairment of lung function occurred in Weeks 3-6. For late changes, the interval to onset was clearly dose dependent and was 17 weeks (10-30 Gy) and 10 weeks (50-60 Gy), respectively. The incidence of the response was highly dependent on the estimated lung dose. The median effective dose for an early and late response was virtually identical (19.9 {+-} 0.6 Gy and 20.4 {+-} 3.1 Gy, respectively). A significant correlation was found between the occurrence of an early and a late effect in the same rat, suggesting a strong consequential component. Conclusions: The effects of radiolabeled microspheres can be studied longitudinally in a rat model, using changes in the breathing rate as the functional, clinically relevant response. The isoeffective doses from the present study using radionuclide administration and those from published investigations of homogeneous external beam radiotherapy are almost similar.« less

  10. Relative Biological Effectiveness of HZE Particles for Chromosomal Exchanges and Other Surrogate Cancer Risk Endpoints

    DOE PAGES

    Cacao, Eliedonna; Hada, Megumi; Saganti, Premkumar B.; ...

    2016-04-25

    The biological effects of high charge and energy (HZE) particle exposures are of interest in space radiation protection of astronauts and cosmonauts, and estimating secondary cancer risks for patients undergoing Hadron therapy for primary cancers. The large number of particles types and energies that makeup primary or secondary radiation in HZE particle exposures precludes tumor induction studies in animal models for all but a few particle types and energies, thus leading to the use of surrogate endpoints to investigate the details of the radiation quality dependence of relative biological effectiveness (RBE) factors. In this report we make detailed RBE predictionsmore » of the charge number and energy dependence of RBE’s using a parametric track structure model to represent experimental results for the low dose response for chromosomal exchanges in normal human lymphocyte and fibroblast cells with comparison to published data for neoplastic transformation and gene mutation. RBE’s are evaluated against acute doses of γ-rays for doses near 1 Gy. Models that assume linear or non-targeted effects at low dose are considered. Modest values of RBE (<10) are found for simple exchanges using a linear dose response model, however in the non-targeted effects model for fibroblast cells large RBE values (>10) are predicted at low doses <0.1 Gy. The radiation quality dependence of RBE’s against the effects of acute doses γ-rays found for neoplastic transformation and gene mutation studies are similar to those found for simple exchanges if a linear response is assumed at low HZE particle doses. Finally, we discuss comparisons of the resulting model parameters to those used in the NASA radiation quality factor function.« less

  11. Targeting of Antithrombin in Hemophilia A or B with RNAi Therapy.

    PubMed

    Pasi, K John; Rangarajan, Savita; Georgiev, Pencho; Mant, Tim; Creagh, Michael D; Lissitchkov, Toshko; Bevan, David; Austin, Steve; Hay, Charles R; Hegemann, Inga; Kazmi, Rashid; Chowdary, Pratima; Gercheva-Kyuchukova, Liana; Mamonov, Vasily; Timofeeva, Margarita; Soh, Chang-Heok; Garg, Pushkal; Vaishnaw, Akshay; Akinc, Akin; Sørensen, Benny; Ragni, Margaret V

    2017-08-31

    Current hemophilia treatment involves frequent intravenous infusions of clotting factors, which is associated with variable hemostatic protection, a high treatment burden, and a risk of the development of inhibitory alloantibodies. Fitusiran, an investigational RNA interference (RNAi) therapy that targets antithrombin (encoded by SERPINC1), is in development to address these and other limitations. In this phase 1 dose-escalation study, we enrolled 4 healthy volunteers and 25 participants with moderate or severe hemophilia A or B who did not have inhibitory alloantibodies. Healthy volunteers received a single subcutaneous injection of fitusiran (at a dose of 0.03 mg per kilogram of body weight) or placebo. The participants with hemophilia received three injections of fitusiran administered either once weekly (at a dose of 0.015, 0.045, or 0.075 mg per kilogram) or once monthly (at a dose of 0.225, 0.45, 0.9, or 1.8 mg per kilogram or a fixed dose of 80 mg). The study objectives were to assess the pharmacokinetic and pharmacodynamic characteristics and safety of fitusiran. No thromboembolic events were observed during the study. The most common adverse events were mild injection-site reactions. Plasma levels of fitusiran increased in a dose-dependent manner and showed no accumulation with repeated administration. The monthly regimen induced a dose-dependent mean maximum antithrombin reduction of 70 to 89% from baseline. A reduction in the antithrombin level of more than 75% from baseline resulted in median peak thrombin values at the lower end of the range observed in healthy participants. Once-monthly subcutaneous administration of fitusiran resulted in dose-dependent lowering of the antithrombin level and increased thrombin generation in participants with hemophilia A or B who did not have inhibitory alloantibodies. (Funded by Alnylam Pharmaceuticals; ClinicalTrials.gov number, NCT02035605 .).

  12. Relative Biological Effectiveness of HZE Particles for Chromosomal Exchanges and Other Surrogate Cancer Risk Endpoints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cacao, Eliedonna; Hada, Megumi; Saganti, Premkumar B.

    The biological effects of high charge and energy (HZE) particle exposures are of interest in space radiation protection of astronauts and cosmonauts, and estimating secondary cancer risks for patients undergoing Hadron therapy for primary cancers. The large number of particles types and energies that makeup primary or secondary radiation in HZE particle exposures precludes tumor induction studies in animal models for all but a few particle types and energies, thus leading to the use of surrogate endpoints to investigate the details of the radiation quality dependence of relative biological effectiveness (RBE) factors. In this report we make detailed RBE predictionsmore » of the charge number and energy dependence of RBE’s using a parametric track structure model to represent experimental results for the low dose response for chromosomal exchanges in normal human lymphocyte and fibroblast cells with comparison to published data for neoplastic transformation and gene mutation. RBE’s are evaluated against acute doses of γ-rays for doses near 1 Gy. Models that assume linear or non-targeted effects at low dose are considered. Modest values of RBE (<10) are found for simple exchanges using a linear dose response model, however in the non-targeted effects model for fibroblast cells large RBE values (>10) are predicted at low doses <0.1 Gy. The radiation quality dependence of RBE’s against the effects of acute doses γ-rays found for neoplastic transformation and gene mutation studies are similar to those found for simple exchanges if a linear response is assumed at low HZE particle doses. Finally, we discuss comparisons of the resulting model parameters to those used in the NASA radiation quality factor function.« less

  13. Characterization of Changes in Gene Expression and Biochemical Pathways at Low Levels of Benzene Exposure

    PubMed Central

    Thomas, Reuben; Hubbard, Alan E.; McHale, Cliona M.; Zhang, Luoping; Rappaport, Stephen M.; Lan, Qing; Rothman, Nathaniel; Vermeulen, Roel; Guyton, Kathryn Z.; Jinot, Jennifer; Sonawane, Babasaheb R.; Smith, Martyn T.

    2014-01-01

    Benzene, a ubiquitous environmental pollutant, causes acute myeloid leukemia (AML). Recently, through transcriptome profiling of peripheral blood mononuclear cells (PBMC), we reported dose-dependent effects of benzene exposure on gene expression and biochemical pathways in 83 workers exposed across four airborne concentration ranges (from <1 ppm to >10 ppm) compared with 42 subjects with non-workplace ambient exposure levels. Here, we further characterize these dose-dependent effects with continuous benzene exposure in all 125 study subjects. We estimated air benzene exposure levels in the 42 environmentally-exposed subjects from their unmetabolized urinary benzene levels. We used a novel non-parametric, data-adaptive model selection method to estimate the change with dose in the expression of each gene. We describe non-parametric approaches to model pathway responses and used these to estimate the dose responses of the AML pathway and 4 other pathways of interest. The response patterns of majority of genes as captured by mean estimates of the first and second principal components of the dose-response for the five pathways and the profiles of 6 AML pathway response-representative genes (identified by clustering) exhibited similar apparent supra-linear responses. Responses at or below 0.1 ppm benzene were observed for altered expression of AML pathway genes and CYP2E1. Together, these data show that benzene alters disease-relevant pathways and genes in a dose-dependent manner, with effects apparent at doses as low as 100 ppb in air. Studies with extensive exposure assessment of subjects exposed in the low-dose range between 10 ppb and 1 ppm are needed to confirm these findings. PMID:24786086

  14. Study of damage to red blood cells exposed to different doses of γ-ray irradiation.

    PubMed

    Xu, Deyi; Peng, Mingxi; Zhang, Zhe; Dong, Guofei; Zhang, Yiqin; Yu, Hongwei

    2012-07-01

    The aims of this research were to study alterations in the ultrastructure of red blood cells, the changes in concentrations of plasma electrolytes and the killing effect of lymphocytes in samples of blood exposed to different doses of γ-ray irradiation. Blood samples were treated with different doses of γ-ray irradiation and then preserved for different periods. Specimens were prepared for standard electron microscopy and transmission electron microscopy. At the same time, changes in the concentrations of Na(+), K(+) and Cl(-) and pH values in the plasma as well as Fas and FasL expression of lymphocytes before and after irradiation were determined. The proportions of reversibly and irreversibly transformed cells, for example, echinocytes, sphero-echinocytes, and degenerated forms, increased with increasing doses of irradiation and storage period, while the number of discocyte shaped red blood cells decreased. The change in K(+) concentration was greater than that of Na+ or Cl(-) after irradiation and was dosage-dependent. Plasma pH was influenced by different doses of radiation and storage time. After exposure to (137)Cs γ-irradiation, the expression of both Fas and FasL in lymphocytes differed significantly from that in the control group: the expression was positively correlated with irradiation dose (r=0.95, 0.96), but no significant difference in the Fas/FasL ratio was observed (P>0.05). We conclude that the ultrastructure of red blood cells is not changed obviously by irradiation with some doses of γ-rays and various periods of storage. However, irradiation does have some dose-dependent and time-dependent adverse effects on the erythrocytes.

  15. Ocular allergy modulation to hi-dose antigen sensitization is a Treg-dependent process.

    PubMed

    Lee, Hyun Soo; Schlereth, Simona; Khandelwal, Payal; Saban, Daniel R

    2013-01-01

    A reproducible method to inhibit allergic immune responses is accomplished with hi-dose Ag sensitization, via intraperitoneal (IP) injection. However, the role of CD4+ CD25+ FoxP3+ T regulatory cells (Treg) in this process is unknown, as is whether such modulation extends to ocular allergy. We therefore determined herein whether hi-dose sensitization modulates ocular allergy, and whether CD4+ CD25+ FoxP3+ Treg are involved. C57BL/6 mice were IP sensitized via low-dose (100 µg) versus hi-dose (1000 µg) ovalbumin (OVA), in aluminum hydroxide (1 mg) and pertussis-toxin (300 ng). Other mice received anti-CD25 Ab (PC61) to ablate Treg during sensitization. In another experiment, Treg from hi-dose sensitized mice were adoptively transferred into low-dose sensitized mice. Once daily OVA challenges were administered. Clinical signs, IgE, T cell cytokines, and eosinophils were assessed. Data revealed that hi-dose, but not low-dose, sensitization led to allergy modulation, indicated by decreased clinical signs, serum IgE levels, Th2 recall responses, and eosinophil recruitment. T cells from hi-dose sensitized mice showed a robust increase in TGF-b production, and Treg from these mice were able to efficiently suppress effector T cell proliferation in vitro. In addition, in vivo Treg ablation in hi-dose sensitized mice revoked allergy modulation. Lastly, Treg from hi-dose sensitized mice were able to adoptively transfer allergy modulation to their low-dose sensitized counterparts. Collectively, these findings indicate that modulation to hi-dose sensitization, which is extended to ocular allergy, occurs in a Treg-dependent manner. In addition, our data suggest that hi-dose sensitization may henceforth facilitate the further examination of CD4+ CD25+ FoxP3+ Treg in allergic disease.

  16. High glucose impaired estrogen receptor alpha signaling via β-catenin in osteoblastic MC3T3-E1.

    PubMed

    Wang, Rui; Gao, Dong; Zhou, Yin; Chen, Lu; Luo, Bin; Yu, Yanrong; Li, Hao; Hu, Jiawei; Huang, Qiren; He, Ming; Peng, Weijie; Luo, Dan

    2017-11-01

    Diabetic Mellitus is a risk factor for osteoporosis. It has been suggested that altered estrogen or estrogen receptor α/β (ERα/β) signaling may be involved in diabetic osteoporosis. The present study is to investigate the effects of high glucose on ERα/β signaling in osteoblastic MC3T3-E1 and how the altered signaling of ERα/β affect osteoblastic bone formation. ERα/β signaling was demonstrated as ERα/β protein expression (Western Blotting) and ER transcription activity (Luciferase Reporter assays). Proliferation (WSK-1 assaying), differentiation (ALP staining) and mineralization (Alizalard Red staining) of MC3T3-E1 were examined to evaluate bone formation function. It has been found that high glucose increased ERα/β expression dose-dependently and time-dependently, but high glucose (33mM) decreased ERα transcription activity. 17β-estradiol increased the ERα/β expression dose-dependently in normal medium, but decreased the ERα/β expression dose-dependently in medium with high glucose (33mM). High glucose decreased bone formation and also decreased the osteogenic effects of 17β-estradiol (10 -8 M). High glucose decreased β-catenin expression dose-dependently and time-dependently. LiCl, an inhibitor of β-catenin degradation, decreased ERα expression but increased ERα transcription activity. When compared with high glucose treatment, LiCl (5mM) increased ALP activity and calcified nodes. Besides, high glucose also decreased the protein expression PI-3K, pAKT/AKT, GSK-3β. In conclusion, the present study suggested that high glucose may impair ERα transcription activity by inhibiting β-catenin signaling in osteoblastic MC3T3-E1, leading decreased bone formation ligand-dependently or ligand-independently. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Ecological and biological characteristics of Drosophila melanogaster features depending on the dose of electromagnetic radiation of various types].

    PubMed

    Babkina, V V; Chernova, G V; Allenova, E A; Endebera, O P; Naumkina, E N

    2013-01-01

    Biological effects of exposure to red light (lambda = 660 +/- 10 nm) on the viability and morphophysiological characteristics of Drosophila melanogaster have been studied. The ability of this physical agent to modify these features is shown. The degree of expression and impact of biological effects depend on the dose, functional and genetic status of the organism. The study of the life expectancy of the exposed to EHF and white light D. melanogaster has revealed that expression of the features depends on the radiation doses, genotype, sex, the nature of the position of wings and lighting conditions. It has been found that the dark mode (24 h-night) is more favorable than the artificial lighting. Individuals with the left wing at the top are more sensitive to the external factors.

  18. The effect of different bleaching wavelengths on the sensitivity of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omotayo, Azeez A.; Cygler, Joanna E.; Sawakuchi, Gabriel O.

    2012-09-15

    Purpose: To determine the effect of different bleaching wavelengths on the response of Al{sub 2}O{sub 3}:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, andmore » 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. Results: The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 {+-} 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 {+-} 0.002)% and (0.035 {+-} 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 {+-} 0.14) min to (1.77 {+-} 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. Conclusions: The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.« less

  19. Role of gamma-aminobutyric acid type A (GABAA) receptor subtypes in acute benzodiazepine physical dependence-like effects: evidence from squirrel monkeys responding under a schedule of food presentation

    PubMed Central

    Fischer, Bradford D.; Teixeira, Laura P.; van Linn, Michael L.; Namjoshi, Ojas A.; Cook, James M.; Rowlett, James K.

    2013-01-01

    Rationale Assays of schedule-controlled responding can be used to characterize the pharmacology of benzodiazepines and other GABAA receptor modulators, and are sensitive to changes in drug effects that are related to physical dependence. Objective The present study used this approach to investigate the role of GABAA receptor subtypes in mediating dependence-like effects following benzodiazepine administration. Methods Squirrel monkeys (n=6) were trained on a fixed-ratio schedule of food reinforcement. Initially, the response rate-decreasing effects of chlordiazepoxide (0.1–10 mg/kg; nonselective GABAA receptor agonist), zolpidem (0.032–1.0 mg/kg; α1 subunit-containing GABAA subtype-preferring agonist) and HZ-166 (0.1–10 mg/kg; functionally selective α2 and α3 subunit-containing GABAA receptor agonist) were assessed. Next, acute dependence-like effects following single injections of chlordiazepoxide, zolpidem and HZ-166 were assessed with flumazenil (0.1–3.2 mg/kg; nonselective GABAA receptor antagonist). Finally, acute dependence-like effects following zolpidem administration were assessed with βCCt and 3-PBC (0.1–3.2 mg/kg and 0.32–10 mg/kg, respectively; α1 subunit-containing GABAA receptor antagonists). Results Chlordiazepoxide, zolpidem and HZ-166 produced dose- and time-dependent decreases in response rates, whereas flumazenil, βCCt and 3-PBC were ineffective. After the drug effects waned, flumazenil produced dose-dependent decreases in response rates following administration of 10 mg/kg chlordiazepoxide and 1.0 mg/kg zolpidem, but not following any dose of HZ-166. Further, both βCCt and 3-PBC produced dose-dependent decreases in response rates when administered after 1.0 mg/kg zolpidem. Conclusions These data raise the possibility that α1 subunit-containing GABAA receptors play a major role in physical dependence-related behaviors following a single injection of a benzodiazepine. PMID:23354533

  20. Role of gamma-aminobutyric acid type A (GABAA) receptor subtypes in acute benzodiazepine physical dependence-like effects: evidence from squirrel monkeys responding under a schedule of food presentation.

    PubMed

    Fischer, Bradford D; Teixeira, Laura P; van Linn, Michael L; Namjoshi, Ojas A; Cook, James M; Rowlett, James K

    2013-05-01

    Assays of schedule-controlled responding can be used to characterize the pharmacology of benzodiazepines and other GABAA receptor modulators, and are sensitive to changes in drug effects that are related to physical dependence. The present study used this approach to investigate the role of GABAA receptor subtypes in mediating dependence-like effects following benzodiazepine administration. Squirrel monkeys (n = 6) were trained on a fixed-ratio schedule of food reinforcement. Initially, the response rate-decreasing effects of chlordiazepoxide (0.1-10 mg/kg; nonselective GABAA receptor agonist), zolpidem (0.032-1.0 mg/kg; α1 subunit-containing GABAA subtype-preferring agonist), and HZ-166 (0.1-10 mg/kg; functionally selective α2 and α3 subunit-containing GABAA receptor agonist) were assessed. Next, acute dependence-like effects following single injections of chlordiazepoxide, zolpidem, and HZ-166 were assessed with flumazenil (0.1-3.2 mg/kg; nonselective GABAA receptor antagonist). Finally, acute dependence-like effects following zolpidem administration were assessed with βCCt and 3-PBC (0.1-3.2 mg/kg and 0.32-10 mg/kg, respectively; α1 subunit-containing GABAA receptor antagonists). Chlordiazepoxide, zolpidem, and HZ-166 produced dose- and time-dependent decreases in response rates, whereas flumazenil, βCCT, and 3-PBC were ineffective. After the drug effects waned, flumazenil produced dose-dependent decreases in response rates following administration of 10 mg/kg chlordiazepoxide and 1.0 mg/kg zolpidem, but not following any dose of HZ-166. Further, both βCCT and 3-PBC produced dose-dependent decreases in response rates when administered after 1.0 mg/kg zolpidem. These data raise the possibility that α1 subunit-containing GABAA receptors play a major role in physical dependence-related behaviors following a single injection of a benzodiazepine.

  1. A-1048400 is a novel, orally active, state-dependent neuronal calcium channel blocker that produces dose-dependent antinociception without altering hemodynamic function in rats.

    PubMed

    Scott, Victoria E; Vortherms, Timothy A; Niforatos, Wende; Swensen, Andrew M; Neelands, Torben; Milicic, Ivan; Banfor, Patricia N; King, Andrew; Zhong, Chengmin; Simler, Gricelda; Zhan, Cenchen; Bratcher, Natalie; Boyce-Rustay, Janel M; Zhu, Chang Z; Bhatia, Pramila; Doherty, George; Mack, Helmut; Stewart, Andrew O; Jarvis, Michael F

    2012-02-01

    Blockade of voltage-gated Ca²⁺ channels on sensory nerves attenuates neurotransmitter release and membrane hyperexcitability associated with chronic pain states. Identification of small molecule Ca²⁺ channel blockers that produce significant antinociception in the absence of deleterious hemodynamic effects has been challenging. In this report, two novel structurally related compounds, A-686085 and A-1048400, were identified that potently block N-type (IC₅₀=0.8 μM and 1.4 μM, respectively) and T-type (IC₅₀=4.6 μM and 1.2 μM, respectively) Ca²⁺ channels in FLIPR based Ca²⁺ flux assays. A-686085 also potently blocked L-type Ca²⁺ channels (EC₅₀=0.6 μM), however, A-1048400 was much less active in blocking this channel (EC₅₀=28 μM). Both compounds dose-dependently reversed tactile allodynia in a model of capsaicin-induced secondary hypersensitivity with similar potencies (EC₅₀=300-365 ng/ml). However, A-686085 produced dose-related decreases in mean arterial pressure at antinociceptive plasma concentrations in the rat, while A-1048400 did not significantly alter hemodynamic function at supra-efficacious plasma concentrations. Electrophysiological studies demonstrated that A-1048400 blocks native N- and T-type Ca²⁺ currents in rat dorsal root ganglion neurons (IC₅₀=3.0 μM and 1.6 μM, respectively) in a voltage-dependent fashion. In other experimental pain models, A-1048400 dose-dependently attenuated nociceptive, neuropathic and inflammatory pain at doses that did not alter psychomotor or hemodynamic function. The identification of A-1048400 provides further evidence that voltage-dependent inhibition of neuronal Ca²⁺ channels coupled with pharmacological selectivity vs. L-type Ca²⁺ channels can provide robust antinociception in the absence of deleterious effects on hemodynamic or psychomotor function. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Comparison of two dosing schedules for subcutaneous injections of low-dose anti-CD20 veltuzumab in relapsed immune thrombocytopenia

    PubMed Central

    Liebman, Howard A.; Saleh, Mansoor N.; Bussel, James B.; Negrea, O. George; Horne, Heather; Wegener, William A.; Goldenberg, David M.

    2016-01-01

    We compared two dosing schedules for subcutaneous injections of a low-dose humanized anti-CD20 antibody, veltuzumab, in immune thrombocytopenia. Fifty adults with primary immune thrombocytopenia, in whom one or more lines of standard therapy had failed and who had a platelet count <30×109/L but no major bleeding, initially received escalating 80, 160, or 320 mg doses of subcutaneous veltuzumab administered twice, 2 weeks apart; the last group received once-weekly doses of 320 mg for 4 weeks. In all dose groups, injection reactions were transient and mild to moderate; there were no other safety issues. Forty-seven response-evaluable patients had 23 (49%) objective responses (platelet counts ≥30×109/L and ≥2 × baseline) including 15 (32%) complete responses (platelets ≥100×109/L). Responses (including complete responses) and bleeding reduction occurred in all dose groups and were not dose-dependent. In contrast, response duration increased progressively with total dose, reaching a median of 2.7 years with the four once-weekly 320-mg doses. Among nine responders retreated at relapse, three at higher dose levels responded again, including one patient who was retreated four times. In all dose groups, B-cell depletion occurred after the first dose until recovery starting 12 to 16 weeks after treatment. Veltuzumab serum levels increased with dose group according to total dose administered, but terminal half-life and clearance were comparable. Human anti-veltuzumab antibody titers developed without apparent dose dependence in nine patients, of whom six responded including five who had complete responses. Subcutaneous veltuzumab was convenient, well-tolerated, and active, without causing significant safety concerns. Platelet responses and bleeding reduction occurred in all dose groups, and response durability appeared to improve with higher doses. Clinicaltrials.gov identifier: NCT00547066 PMID:27515248

  3. Epiphytic lichenosynusia under conditions of chemical pollution: Dose-effect dependencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mikhailova, I.N.; Vorobeichik, E.L.

    1995-11-01

    The dose-effect dependencies, which characterize response of the epiphytic lichenosynusia of southern taiga in the Middle Urals to pollution by discharges of a copper-smelting plant, are substantially non-linear and, in most cases, have an S-shaped form. A transition from background to impact state is very sharp and begins when the background level of pollution is exceeded by 1.5 - 2.3 times.

  4. DIMETHYLARSINIC ACID ALTERS EXPRESSION OF OXIDATIVE STRESS AND DNA REPAIR GENES IN A DOSE DEPENDENT MANNER IN THE TRANSITIONAL EPITHELIUM OF THE URINARY BLADDER FROM FEMALE F344 RATS.

    EPA Science Inventory

    Dose-dependent alteration of oxidative stress and DNA repair gene expression by Dimethylarsinic acid [DMA(V)] in transitional epithelium of urinary bladder from female F344 rats.
    Arsenic (As) is a major concern as millions of people are at risk from drinking arsenic contaminat...

  5. Comparative Proteomic Analysis of Liver Steatosis and Fibrosis after Oral Hepatotoxicant Administration in Sprague-Dawley Rats.

    PubMed

    McDyre, B Claire; AbdulHameed, Mohamed Diwan M; Permenter, Matthew G; Dennis, William E; Baer, Christine E; Koontz, Jason M; Boyle, Molly H; Wallqvist, Anders; Lewis, John A; Ippolito, Danielle L

    2018-02-01

    The past decade has seen an increase in the development and clinical use of biomarkers associated with histological features of liver disease. Here, we conduct a comparative histological and global proteomics analysis to identify coregulated modules of proteins in the progression of hepatic steatosis or fibrosis. We orally administered the reference chemicals bromobenzene (BB) or 4,4'-methylenedianiline (4,4'-MDA) to male Sprague-Dawley rats for either 1 single administration or 5 consecutive daily doses. Livers were preserved for histopathology and global proteomics assessment. Analysis of liver sections confirmed a dose- and time-dependent increase in frequency and severity of histopathological features indicative of lipid accumulation after BB or fibrosis after 4,4'-MDA. BB administration resulted in a dose-dependent increase in the frequency and severity of inflammation and vacuolation. 4,4'-MDA administration resulted in a dose-dependent increase in the frequency and severity of periportal collagen accumulation and inflammation. Pathway analysis identified a time-dependent enrichment of biological processes associated with steatogenic or fibrogenic initiating events, cellular functions, and toxicological states. Differentially expressed protein modules were consistent with the observed histology, placing physiologically linked protein networks into context of the disease process. This study demonstrates the potential for protein modules to provide mechanistic links between initiating events and histopathological outcomes.

  6. Toxicity of 6-thioguanine: no hepatotoxicity in a series of IBD patients treated with long-term, low dose 6-thioguanine. Some evidence for dose or metabolite level dependent effects?

    PubMed

    Gilissen, L P L; Derijks, L J J; Driessen, A; Bos, L P; Hooymans, P M; Stockbrügger, R W; Engels, L G J B

    2007-02-01

    6-Thioguanine is used in inflammatory bowel disease since 2001, with promising short-term results. In 2003, liver histology of some 6-thioguanine treated patients showed nodular regenerative hyperplasia. Recently, magnetic resonance imaging revealed nodular regenerative hyperplasia in patients with normal histology. Investigating the presence of nodular regenerative hyperplasia in long-term 6-thioguanine treated patients. Inflammatory bowel disease patients, using 6-thioguanine minimally 24 months, were asked to undergo liver biopsy and magnetic resonance imaging. Fourteen patients used 6-thioguanine minimally 24 months, 13 participated. Mean 6-thioguanine therapy duration, daily dose and 6-thioguanine nucleotide levels were: 36 months, 18.8 mg (0.28 mg/kg) and 705 pmol/8x10(8) erythrocytes, respectively. Liver histology and magnetic resonance imaging showed no nodular regenerative hyperplasia. Liver biopsy and magnetic resonance imaging showed no nodular regenerative hyperplasia in these long-term 6-thioguanine treated inflammatory bowel disease patients. 6-thioguanine dose and metabolite levels were lower compared with previous nodular regenerative hyperplasia reports, suggesting dose or metabolite level-dependent effects. Otherwise, nodular regenerative hyperplasia is related with inflammatory bowel disease itself and immunosuppressives, including azathioprine and 6-mercaptopurine. 6-Thioguanine is debated due to nodular regenerative hyperplasia. We found no nodular regenerative hyperplasia in inflammatory bowel disease patients with long-term, low dosed 6-thioguanine, suggesting metabolite level-dependent effects. Therefore, 6-thioguanine still seems useful, but in selected patients, intolerant for other immunosuppressives, low dosed and under close surveillance of metabolite levels and hepatotoxity.

  7. Skin dose mapping for fluoroscopically guided interventions.

    PubMed

    Johnson, Perry B; Borrego, David; Balter, Stephen; Johnson, Kevin; Siragusa, Daniel; Bolch, Wesley E

    2011-10-01

    To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

  8. Angular dependence of dose sensitivity of nanoDot optically stimulated luminescent dosimeters in different radiation geometries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jursinic, Paul A., E-mail: pjursinic@wmcc.org

    2015-10-15

    Purpose: A type of in vivo dosimeter, an optically stimulated luminescent dosimeter, OSLD, may have dose sensitivity that depends on the angle of incidence of radiation. This work measures how angular dependence of a nanoDot changes with the geometry of the phantom in which irradiation occurs and with the intrinsic structure of the nanoDot. Methods: The OSLDs used in this work were nanoDot dosimeters (Landauer, Inc., Glenwood, IL), which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). Dose to the OSLDs was delivered by 6 MV x-rays. NanoDots with various intrinsic sensitivities were irradiated in numerous phantoms thatmore » had geometric shapes of cylinders, rectangles, and a cube. Results: No angular dependence was seen in cylindrical phantoms, cubic phantoms, or rectangular phantoms with a thickness to width ratio of 0.3 or 1.5. An angular dependence of 1% was observed in rectangular phantoms with a thickness to width of 0.433–0.633. A group of nanoDots had sensitive layers with mass density of 2.42–2.58 g/cm{sup 3} and relative sensitivity of 0.92–1.09 and no difference in their angular dependence. Within experimental uncertainty, nanoDot measurements agree with a parallel-plate ion chamber at a depth of maximum dose. Conclusions: When irradiated in cylindrical, rectangular, and cubic phantoms, nanoDots show a maximum angular dependence of 1% or less at an incidence angle of 90°. For a sample of 78 new nanoDots, the range of their relative intrinsic sensitivity is 0.92–1.09. For a sample of ten nanoDots, on average, the mass in the sensitive layer is 73.1% Al{sub 2}O{sub 3}:C and 26.9% polyester. The mass density of the sensitive layer of a nanoDot disc is between 2.42 and 2.58 g/cm{sup 3}. The angular dependence is not related to Al{sub 2}O{sub 3}:C loading of the nanoDot disc. The nanoDot at the depth of maximum dose has no more angular dependence than a parallel-plate ion chamber.« less

  9. Short and long-term exposure of CNS cell lines to BPA-f a radiosensitizer for boron neutron capture therapy: safety dose evaluation by a battery of cytotoxicity tests.

    PubMed

    De Simone, U; Manzo, L; Ferrari, C; Bakeine, J; Locatelli, C; Coccini, T

    2013-03-01

    Despite the current clinical use of boronophenylalanine-fructose (BPA-f), as radiosensitizer, in BNCT application for brain tumors, still remains to be determined the safety dose of this agent. We evaluated the potential risk of primary BPA-f toxicity before neutronic irradiation at different concentrations (0-100μgBeq/ml) after short- and long-term exposure (4-48h and 7-10 days), using a battery of tests (i.e. MTT assay, calcein-AM/Propidium Iodide staining, clonogenic test) in CNS cell models (D384 and SH-SY5Y), and non-neuronal primary human fibroblasts (F26). MTT data showed: (i) no cytotoxic effects after short-term exposure (4h) to any of BPA-f concentrations tested in all cell models; (ii) dose- and time-dependent mitochondrial activity impairment in D384 and SH-SY5Y cells only (with 60% and 40% cell death in D384 and SH-SY5Y, respectively, after 48h exposure to BPA-f 100μgBeq/ml). By Calcein-AM/PI staining, BPA-f treatment was specific toward SH-SY5Y cells only: a dose-dependent cell density reduction was observed, with a more pronounced effect after 48h exposure (15-40% at doses ranging 20-100μgBeq/ml). Clonogenic data revealed dose-dependent decrease of cell proliferative capacity in all cell lines, still the SH-SY5Y cells were the most sensitive ones: the lowest dose (20μgBeq/ml) produced 90% cell decrease. These results indicate dose- and time-dependent cytotoxic effects of BPA-f, with CNS cells showing a lower tolerance compared to fibroblasts. Long-term exposure to BPA-f compromised the proliferative capacity regardless of cell model type (cell sensitivity being SH-SY5Y>D384>F26). In short-time exposure, BPA-f exhibits a safe dosage up to 40μgBeq/ml for the viability of CNS cell lines. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Technical Note: Initial characterization of the new EBT-XD Gafchromic film.

    PubMed

    Grams, Michael P; Gustafson, Jon M; Long, Kenneth M; de los Santos, Luis E Fong

    2015-10-01

    To assess the dosimetric accuracy and energy dependence of the new EBT-eXtended Dose (XD) Gafchromic film and to compare the lateral response artifact (LRA) between EBT-XD and EBT3 film. EBT3 and EBT-XD calibration curves were created by exposing films to known doses from 0 to 3000 cGy using a 6 MV beam. To assess the accuracy and dynamic range of EBT-XD, a 60° enhanced dynamic wedge (EDW) was used to deliver a dose range of approximately 200-2900 cGy. Comparison to treatment planning system (TPS) calculation was made using a gamma analysis with 2%/2 mm passing criteria. To assess and compare the LRA between EBT3 and EBT-XD, 21 × 21 cm(2) open fields delivered doses of 1000, 2000, and 3000 cGy to both types of film. Films were placed at the center of the scanner, and ratios of measured to TPS predicted doses were calculated at 50 and 80 mm lateral from the scanner center in order to quantitatively assess the LRA. To evaluate the energy dependence of EBT-XD film, seven known doses ranging from 400 to 3000 cGy were delivered using both 6 and 18 MV beams and the resulting optical densities (ODs) compared. The gamma passing rate was 99.1% for the 6 MV EDW delivery. EBT-XD film exhibited minimal LRA (<1%) up to 3000 cGy. In contrast, EBT3 demonstrated an under-response of 11.3% and 22.7% at lateral positions of 50 and 80 mm, respectively, for the 3000 cGy exposure. Differences between ODs of the EBT-XD films exposed to known doses from 6 to 18 MV beams were <0.8% suggesting minimal energy dependence throughout this energy range. The LRA of EBT-XD is greatly reduced when compared to EBT3. This in combination with its accuracy from 0 to 3000 cGy and minimal energy dependence from 6 to 18 MV makes EBT-XD film well suited for dosimetric measurements in high dose SRS/SBRT applications.

  11. Inhaled nitric oxide, oxygen, and alkalosis: dose-response interactions in a lamb model of pulmonary hypertension.

    PubMed

    Heidersbach, R S; Johengen, M J; Bekker, J M; Fineman, J R

    1999-07-01

    Inhaled nitric oxide (NO) is currently used as an adjuvant therapy for a variety of pulmonary hypertensive disorders. In both animal and human studies, inhaled NO induces selective, dose-dependent pulmonary vasodilation. However, its potential interactions with other simultaneously used pulmonary vasodilator therapies have not been studied. Therefore, the objective of this study was to determine the potential dose-response interactions of inhaled NO, oxygen, and alkalosis therapies. Fourteen newborn lambs (age 1-6 days) were instrumented to measure vascular pressures and left pulmonary artery blood flow. After recovery, the lambs were sedated and mechanically ventilated. During steady-state pulmonary hypertension induced by U46619 (a thromboxane A2 mimic), the lambs were exposed to the following conditions: Protocol A, inhaled NO (0, 5, 40, and 80 ppm) and inspired oxygen concentrations (FiO2) of 0.21, 0.50, and 1.00; and Protocol B, inhaled NO (0, 5, 40, and 80 ppm) and arterial pH levels of 7.30, 7.40, 7.50, and 7.60. Each condition (in randomly chosen order) was maintained for 10 min, and all variables were allowed to return to baseline between conditions. Inhaled NO, oxygen, and alkalosis produced dose-dependent decreases in mean pulmonary arterial pressures (P < 0.05). Systemic arterial pressure remained unchanged. At 5 ppm of inhaled NO, alkalosis and oxygen induced further dose-dependent decreases in mean pulmonary arterial pressures (P < 0.05). At inhaled NO doses > 5 ppm, alkalosis induced further dose-independent decreases in mean pulmonary arterial pressure, while oxygen did not. We conclude that in this animal model, oxygen, alkalosis, and inhaled NO induced selective, dose-dependent pulmonary vasodilation. However, when combined, a systemic arterial pH > 7.40 augmented inhaled NO-induced pulmonary vasodilation, while an FiO2 > 0.5 did not. Therefore, weaning high FiO2 during inhaled NO therapy should be considered, since it may not diminish the pulmonary vasodilating effects. Further studies are warranted to guide the clinical weaning strategies of these pulmonary vasodilator therapies.

  12. Exercise-Induced Dose-Response Alterations in Adiponectin and Leptin Levels Are Dependent on Body Fat Changes in Women at Risk for Breast Cancer.

    PubMed

    Sturgeon, Kathleen; Digiovanni, Laura; Good, Jerene; Salvatore, Domenick; Fenderson, Desiré; Domchek, Susan; Stopfer, Jill; Galantino, Mary Lou; Bryan, Cathy; Hwang, Wei-Ting; Schmitz, Kathryn

    2016-08-01

    Dysregulation of adipokines, such as adiponectin and leptin, is associated with a variety of chronic diseases, including cancer. Physical activity protects against breast cancer and one of the mechanisms which may underlie this association is exercise-induced changes in adipokine levels. The WISER Sister Trial was a three-armed randomized controlled trial in premenopausal women (n = 137) with an elevated risk for breast cancer. A 5-menstrual-cycle-long dosed aerobic exercise intervention compared low-dose exercise (150 min/wk; n = 44) or high-dose exercise (300 min/wk; n = 48) with a control group asked to maintain usual activity levels (n = 45). Exercise intensity progressed to and was maintained at 70% to 80% of age predicted heart rate max. Body composition and adipokine levels were measured at baseline and follow-up. We observed significant linear trends for increased fitness capacity (Δ%: -2.0% control, 10.1% low dose, 13.1% high dose), decreased fat tissue-to-total tissue mass (Δ%: 0.7% control, -2.9% low dose, -3.7% high dose), increased body fat adjusted adiponectin (Δ%: -0.6% control, 0.6% low dose, 0.9% high dose), and decreased body fat adjusted leptin (Δ%: 0.7% control, -8.2% low dose, -10.2% high dose). In this randomized clinical trial of premenopausal women at risk for breast cancer, we demonstrate a dose-response effect of exercise on adiponectin and leptin and that dose response is dependent on changes in body fat. Improved adipokine levels, achieved by aerobic exercise training-induced decreases in body fat, may decrease breast cancer risk for high-risk premenopausal women. Cancer Epidemiol Biomarkers Prev; 25(8); 1195-200. ©2016 AACR. ©2016 American Association for Cancer Research.

  13. Monte Carlo Assessments of Absorbed Doses to the Hands of Radiopharmaceutical Workers Due to Photon Emitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Dan; Eckerman, Keith F; Karagiannis, Harriet

    This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters that are used to show compliance with applicable regulations may overestimate or underestimate radiation doses to the skin depending on the nature of the particular procedure and the radionuclide being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations of realistic configurations typical for workers handling radiopharmaceuticals weremore » performedfor a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from dosimeter readings when dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.« less

  14. Dose Assessments to the Hands of Radiopharmaceutical Workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Dan; Eckerman, Keith F; Sherbini, Sami

    This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters may overestimate or underestimate the radiation doses to the skin that are used to show compliance with applicable regulations depending on the nature of the particular procedure and the radioisotope being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations on realistic configurations typical for workers handling radiopharmaceuticalsmore » were performed for a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from the dosimeters' readings when the dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.« less

  15. Effects of chromium picolinate on oxidative damage in primary piglet hepatocytes.

    PubMed

    Tan, Gao-Yi; Bi, Jin-Ming; Zhang, Min-Hong; Feng, Jing-Hai; Xie, Peng; Zheng, Shan-Shan

    2008-12-01

    Chromium picolinate is a popular nutritional supplement whose safety has been questioned because of the potential risk of oxidative DNA damage. To investigate this possibility, a dose-dependent study was performed in piglet hepatocyte cultures in which low (8 microM), medium (200 microM), and high (400 microM) doses of chromium picolinate were tested and compared to untreated controls. After 48 h incubation, there were no significant differences in the levels of intracellular reactive oxygen species, medium lactate dehydrogenase activity, and comet indicators between the three experimental groups and controls (p > 0.05). In the 8 microM-treated group, the intracellular malondialdehyde content was significantly decreased relative to controls (p < 0.05). All of the studied parameters showed a dose-dependent increase that was statistically significant between the low and high doses (p < 0.05). These results suggest that: (1) chromium picolinate may affect the oxidative status of piglet hepatocytes; (2) the appropriate dose (approximately physiological concentration) of chromium picolinate can inhibit lipid peroxidation, and (3) high doses of chromium picolinate have no significant effects on oxidative damage in piglet hepatocytes, but the existing evidence also imply that exposure to a higher dose appears to be unwarranted.

  16. Dose-dependent analysis of acute medical effects of mixed neutron-gamma radiation from selected severe 235U or 239Pu criticality accidents in USSR, United States, and Argentina.

    PubMed

    Barabanova, Tatyana; Wiley, Albert L; Bushmanov, Andrey

    2012-04-01

    Eight of the most severe cases of acute radiation disease (ARS) known to have occurred in humans (as the result of criticality accidents) had survival times less than 120 h (herein defined as "early death"). These accidents were analyzed and are discussed with respect to the specific accident scenarios and the resulting accident-specific, mixed neutron-gamma radiation clinical dose distributions. This analysis concludes that the cardiovascular system appears to be the most critical organ system failure for causing "early death" following approximate total body, mixed gamma-neutron radiation doses greater than 40-50 Gy. The clinical data also suggest that there was definite chest dose dependence in the resulting survival times for these eight workers, who unfortunately suffered profound radiation injury and unusual clinical effects from such high dose radiation exposures. In addition, "toxemic syndrome" is correlated with the irradiation of large volumes of soft tissues. Doses to the hands or legs greater than 80-100 Gy or radiation lung injury also play significant but secondary roles in causing "early death" in accidents delivering chest doses greater than 50 Gy.

  17. Mitigation of paracetamol-induced reproductive damage by chrysin in male rats via reducing oxidative stress.

    PubMed

    Aksu, E H; Özkaraca, M; Kandemir, F M; Ömür, A D; Eldutar, E; Küçükler, S; Çomaklı, S

    2016-12-01

    Paracetamol (PRC) is a nonsteroidal anti-inflammatory drug used widely as a painkiller for various diseases and as the symptomatic flu cure in several countries worldwide. PRC toxicity may occur under conditions of the overdose usage. Chrysin (CR) is a flavonoid that is naturally present in several plants, honey and propolis. The aim of this study was to investigate the effects of CR (at the doses of 25 mg kg -1 and 50 mg kg -1 ) pre-treatment over seven consecutive days against PRC-induced reproductive toxicity in male rats. Our results showed that PRC toxicity decreased the sperm motility, and increased dead sperm rate, abnormal sperm cell rate, apoptosis and MDA levels in testicular tissues. Pre-treatment with CR at the dose of 25 and 50 mg kg -1 for 7 days mitigated side effects of acute PRC toxicity in male reproductive system proportionally in a dose-dependent manner. This possible protection mechanism might be dependent on the antioxidant activity of CR. In conclusion, pre-treatment with CR at the dose of 25 and 50 mg kg -1 for 7 days can be the beneficial against PRC-induced reproductive toxicity proportionally in a dose-dependent manner. © 2016 Blackwell Verlag GmbH.

  18. RU486 did not exacerbate cytokine release in mice challenged with LPS nor in db/db mice

    PubMed Central

    Yang, Baichun; Trump, Ryan P; Shen, Ying; McNulty, Judi A; Clifton, Lisa G; Stimpson, Stephen A; Lin, Peiyuan; Pahel, Greg L

    2008-01-01

    Background Glucocorticoids down-regulate cytokine synthesis and suppress inflammatory responses. The glucocorticoid receptor (GR) antagonist RU486 may exacerbate the inflammatory response, and concerns over this exacerbation have limited the development and clinical use of GR antagonists in the treatment of diabetes and depression. We investigated the effects of RU486 on serum cytokines in db/db mice and on lipopolysaccharide (LPS)-induced circulating TNFα levels in both normal AKR mice and diet-induced obese (DIO) C57BL/6 mice. Results Chronic treatment of db/db mice with RU486 dose-dependently decreased blood glucose, increased serum corticosterone and ACTH, but did not affect serum MCP-1 and IL-6 levels. LPS dose-dependently increased serum TNFα in both AKR and C57BL/6 DIO mice, along with increased circulating corticosterone and ACTH. Pretreatment of the mice with RU486 dose-dependently suppressed the LPS induced increases in serum TNFα and further increased serum corticosterone. Conclusion RU486 at doses that were efficacious in lowering blood glucose did not exacerbate cytokine release in these three mouse models. RU486 actually suppressed the lower dose LPS-mediated TNFα release, possibly due to the increased release of glucocorticoids. PMID:18474108

  19. Evaluation of the reinforcing and subjective effects of heroin in combination with dextromethorphan and quinidine

    PubMed Central

    Vosburg, Suzanne K.; Sullivan, Maria A.; Comer, Sandra D.

    2015-01-01

    Objective Studies have suggested that the N-methyl-d-aspartate antagonist dextromethorphan may be useful in the treatment of opioid dependence. Design This double-blinded, placebo-controlled inpatient study evaluated the effects of 0, 30, and 60 mg of dextromethorphan and quinidine (DMQ) on the reinforcing and subjective effects of heroin in recently detoxified heroin abusers. Participants Nine heroin-dependent participants were admitted and then detoxified from heroin over the course of several days. Interventions Participants were subsequently stabilized on 0, 30, or 60 mg of DMQ. Each dose of DMQ was administered for two consecutive weeks, and the effects of heroin (0, 12.5, and 50 mg) were studied under each DMQ maintenance dose condition. DMQ and heroin dose were administered in random order both within and between participants. Results Planned comparisons revealed statistically significant increases in progressive ratio breakpoint values and positive subjective ratings as a function of heroin dose. There were no consistent changes in any of the responses as a function of DMQ maintenance dose, other than a modest reduction in craving. Conclusions In summary, results from this study suggest that maintenance on dextromethorphan in combination with quinidine has a limited role in the treatment of opioid dependence. PMID:22320027

  20. Safety, tolerability, and cerebrospinal fluid penetration of ursodeoxycholic Acid in patients with amyotrophic lateral sclerosis.

    PubMed

    Parry, Gareth J; Rodrigues, Cecilia M P; Aranha, Marcia M; Hilbert, Sarah J; Davey, Cynthia; Kelkar, Praful; Low, Walter C; Steer, Clifford J

    2010-01-01

    Amyotrophic lateral sclerosis is a progressive degenerative disease, which typically leads to death in 3 to 5 years. Neuronal cell death offers a potential target for therapeutic intervention. Ursodeoxycholic acid is a cytoprotective, endogenous bile acid that has been shown to be neuroprotective in experimental Huntington and Alzheimer diseases, retinal degeneration, and ischemic and hemorrhagic stroke. The objective of this research was to study the safety and the tolerability of ursodeoxycholic acid in amyotrophic lateral sclerosis and document effective and dose-dependent cerebrospinal fluid penetration. Eighteen patients were randomly assigned to receive ursodeoxycholic acid at doses of 15, 30, and 50 mg/kg of body weight per day. Serum and cerebrospinal fluid were obtained for analysis after 4 weeks of treatment. Treatment-emergent clinical and laboratory events were monitored weekly. Our data indicated that ursodeoxycholic acid is well tolerated by all subjects at all doses. We also showed that ursodeoxycholic acid is well absorbed after oral administration and crosses the blood-brain barrier in a dose-dependent manner. These results show excellent safety and tolerability of ursodeoxycholic acid. The drug penetrates the cerebrospinal fluid in a dose-dependent manner. A large, placebo-controlled clinical trial is needed to assess the efficacy of ursodeoxycholic acid in treating amyotrophic lateral sclerosis.

  1. Low doses of glyphosate enhance growth, CO2 assimilation, stomatal conductance and transpiration in sugarcane and eucalyptus.

    PubMed

    Nascentes, Renan F; Carbonari, Caio A; Simões, Plinio S; Brunelli, Marcela C; Velini, Edivaldo D; Duke, Stephen O

    2018-05-01

    Sublethal doses of herbicides can enhance plant growth and stimulate other process, an effect known as hormesis. The magnitude of hormesis is dependent on the plant species, the herbicide and its dose, plant development stage and environmental parameters. Glyphosate hormesis is well established, but relatively little is known of the mechanism of this phenomenon. The objective of this study was to determine if low doses of glyphosate that cause growth stimulation in sugarcane and eucalyptus concomitantly stimulate CO 2 assimilation. Shoot dry weight in both species increased at both 40 and 60 days after application of 6.2 to 20.2 g a.e. ha -1 glyphosate. The level of enhanced shoot dry weight was 11 to 37%, depending on the time after treatment and the species. Concomitantly, CO 2 assimilation, stomatal conductance and transpiration were increased by glyphosate doses similar to those that caused growth increases. Glyphosate applied at low doses increased the dry weight of sugarcane and eucalyptus plants in all experiments. This hormetic effect was related to low dose effects on CO 2 assimilation rate, stomatal conductance and transpiration rate, indicating that low glyphosate doses enhance photosynthesis of plants. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. Effects of the food additive, citric acid, on kidney cells of mice.

    PubMed

    Chen, Xg; Lv, Qx; Liu, Ym; Deng, W

    2015-01-01

    Citric acid is a food additive that is widely used in the food and drink industry. We investigated the effects of citric acid injection on mouse kidney. Forty healthy mice were divided into four groups of 10 including one control group and three citric acid-treated groups. Low dose, middle dose and high dose groups were given doses of 120, 240 and 480 mg/kg of citric acid, respectively. On day 7, kidney tissues were collected for histological, biochemical and molecular biological examination. We observed shrinkage of glomeruli, widened urinary spaces and capillary congestion, narrowing of the tubule lumen, edema and cytoplasmic vacuolated tubule cells, and appearance of pyknotic nuclei. The relation between histopathological changes and citric acid was dose dependent. Compared to the control, T-SOD and GSH-Px activities in the treated groups decreased with increasing doses of citric acid, NOS activity tended to increase, and H2O2 and MDA contents gradually decreased, but the differences between any treated group and the control were not statistically significant. The apoptosis assay showed a dose-dependent increase of caspase-3 activity after administering citrate that was statistically significant. DNA ladder formation occurred after treatment with any dose of citric acid. We concluded that administration of citric acid may cause renal toxicity in mice.

  3. Characterization of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure.

    PubMed

    Bassinet, Céline; Huet, Christelle; Baumann, Marion; Etard, Cécile; Réhel, Jean-Luc; Boisserie, Gilbert; Debroas, Jacques; Aubert, Bernard; Clairand, Isabelle

    2013-04-01

    As MOSFET (Metal Oxide Semiconductor Field Effect Transistor) detectors allow dose measurements in real time, the interest in these dosimeters is growing. The aim of this study was to investigate the dosimetric properties of commercially available TN-502RD-H MOSFET silicon detectors (Best Medical Canada, Ottawa, Canada) in order to use them for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure. Reproducibility of the measurements, dose rate dependence, and dose response of the MOSFET detectors have been studied with a Co source. Influence of the dose rate, frequency, and pulse duration on MOSFET responses has also been studied in pulsed x-ray fields. Finally, in order to validate the integrated dose given by MOSFET detectors, MOSFETs and TLDs (LiF:Mg,Cu,P) were fixed on an Alderson-Rando phantom in the conditions of an interventional neuroradiology procedure, and their responses have been compared. The results of this study show the suitability of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of accident, provided a well-corrected energy dependence, a pulse duration equal to or higher than 10 ms, and an optimized contact between the detector and the skin of the patient are achieved.

  4. Low doses of glyphosate enhance growth, CO2 assimilation, stomatal conductance and transpiration in sugarcane and eucalyptus

    USDA-ARS?s Scientific Manuscript database

    Sublethal doses of herbicides can enhance plant growth and stimulate other process, an effect known as hormesis. The magnitude of hormesis is dependent on the plant species, the herbicide and its dose, plant development stage, and environmental parameters. Glyphosate hormesis is well established, bu...

  5. Effects of medetomidine on serum glucose in cattle calves.

    PubMed

    Tariq, Muhammad; Kalhoro, Amir Bukhsh; Sarwar, Mian Saeed; Khan, Hamayun; Ahmad, Shakoor; Hassan, Sayed Mubashir; Zahoor, Arshad

    2016-05-01

    An experimental study was carried out to compare physiological effects (serum glucose level) of medetomidine in Red Sindhi cattle calves at three different doses i.e. 8, 10 and 12µg/kg body weight intravenously. Medetomidine produced a dose dependent significant (P<0.01) increase in serum glucose level with a maximum increase observed at 30 minutes with 8µg/kg, 10μg/kg and 12μg/kg body weight respectively. Start of sedation, degree of sedation and total duration of sedation were all dose dependent and the values obtained were significantly (P<0.01) different from each other. It was observed that the sedation was rapid, deep and longer with the higher doses of medetomidine i.e. 12μg/kg. The results of the present study shows that medetomidine is a very effective and safest drug use as sedative for calves which in lower doses (8μg/kg) can be used as a pre-anesthetic and for restraining of the animal, while higher calculated doses (10μg/kg, 12μg/kg) can be used to execute the minor surgical procedures.

  6. Dependency of EBT2 film calibration curve on postirradiation time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Liyun, E-mail: liyunc@isu.edu.tw; Ding, Hueisch-Jy; Ho, Sheng-Yow

    2014-02-15

    Purpose: The Ashland Inc. product EBT2 film model is a widely used quality assurance tool, especially for verification of 2-dimensional dose distributions. In general, the calibration film and the dose measurement film are irradiated, scanned, and calibrated at the same postirradiation time (PIT), 1-2 days after the films are irradiated. However, for a busy clinic or in some special situations, the PIT for the dose measurement film may be different from that of the calibration film. In this case, the measured dose will be incorrect. This paper proposed a film calibration method that includes the effect of PIT. Methods: Themore » dose versus film optical density was fitted to a power function with three parameters. One of these parameters was PIT dependent, while the other two were found to be almost constant with a standard deviation of the mean less than 4%. The PIT-dependent parameter was fitted to another power function of PIT. The EBT2 film model was calibrated using the PDD method with 14 different PITs ranging from 1 h to 2 months. Ten of the fourteen PITs were used for finding the fitting parameters, and the other four were used for testing the model. Results: The verification test shows that the differences between the delivered doses and the film doses calculated with this modeling were mainly within 2% for delivered doses above 60 cGy, and the total uncertainties were generally under 5%. The errors and total uncertainties of film dose calculation were independent of the PIT using the proposed calibration procedure. However, the fitting uncertainty increased with decreasing dose or PIT, but stayed below 1.3% for this study. Conclusions: The EBT2 film dose can be modeled as a function of PIT. For the ease of routine calibration, five PITs were suggested to be used. It is recommended that two PITs be located in the fast developing period (1∼6 h), one in 1 ∼ 2 days, one around a week, and one around a month.« less

  7. Testosterone Dose Dependently Prevents Bone and Muscle Loss in Rodents after Spinal Cord Injury

    PubMed Central

    Conover, Christine F.; Beggs, Luke A.; Beck, Darren T.; Otzel, Dana M.; Balaez, Alexander; Combs, Sarah M.; Miller, Julie R.; Ye, Fan; Aguirre, J. Ignacio; Neuville, Kathleen G.; Williams, Alyssa A.; Conrad, Bryan P.; Gregory, Chris M.; Wronski, Thomas J.; Bose, Prodip K.; Borst, Stephen E.

    2014-01-01

    Abstract Androgen administration protects against musculoskeletal deficits in models of sex-steroid deficiency and injury/disuse. It remains unknown, however, whether testosterone prevents bone loss accompanying spinal cord injury (SCI), a condition that results in a near universal occurrence of osteoporosis. Our primary purpose was to determine whether testosterone-enanthate (TE) attenuates hindlimb bone loss in a rodent moderate/severe contusion SCI model. Forty (n=10/group), 14 week old male Sprague-Dawley rats were randomized to receive: (1) Sham surgery (T9 laminectomy), (2) moderate/severe (250 kdyne) SCI, (3) SCI+Low-dose TE (2.0 mg/week), or (4) SCI+High-dose TE (7.0 mg/week). Twenty-one days post-injury, SCI animals exhibited a 77–85% reduction in hindlimb cancellous bone volume at the distal femur (measured via μCT) and proximal tibia (measured via histomorphometry), characterized by a >70% reduction in trabecular number, 13–27% reduction in trabecular thickness, and increased trabecular separation. A 57% reduction in cancellous volumetric bone mineral density (vBMD) at the distal femur and a 20% reduction in vBMD at the femoral neck were also observed. TE dose dependently prevented hindlimb bone loss after SCI, with high-dose TE fully preserving cancellous bone structural characteristics and vBMD at all skeletal sites examined. Animals receiving SCI also exhibited a 35% reduction in hindlimb weight bearing (triceps surae) muscle mass and a 22% reduction in sublesional non-weight bearing (levator ani/bulbocavernosus [LABC]) muscle mass, and reduced prostate mass. Both TE doses fully preserved LABC mass, while only high-dose TE ameliorated hindlimb muscle losses. TE also dose dependently increased prostate mass. Our findings provide the first evidence indicating that high-dose TE fully prevents hindlimb cancellous bone loss and concomitantly ameliorates muscle loss after SCI, while low-dose TE produces much less profound musculoskeletal benefit. Testosterone-induced prostate enlargement, however, represents a potential barrier to the clinical implementation of high-dose TE as a means of preserving musculoskeletal tissue after SCI. PMID:24378197

  8. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deeg, H.J.; Storb, R.; Weiden, P.L.

    1981-11-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs diedmore » from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors.« less

  9. Impact of angiotensin-converting enzyme gene polymorphism on neurohormonal responses to high- versus low-dose enalapril in advanced heart failure.

    PubMed

    Tang, W H Wilson; Vagelos, Randall H; Yee, Yin-Gail; Fowler, Michael B

    2004-11-01

    The impact of angiotensin-converting enzyme (ACE) gene polymorphism on neurohormonal dose response to ACE inhibitor therapy is unclear. ACE Insertion (I) or Deletion (D) genotype was determined in 74 patients with chronic heart failure who were randomly assigned to receive either high-dose or low-dose enalapril over a period of 6 months. Monthly pre-enalapril and post-enalapril neurohormone levels (serum ACE activity (sACE), plasma angiotensin II (A-II), plasma renin activity (PRA), and serum aldosterone (ALDO) were compared between genotype subgroups and between patients who received high- or low-dose enalapril within each genotype subgroup. At baseline, predose/postdose sACE and postdose PRA were significantly higher in the DD genotype. At 6-month follow-up, postdose sACE was reduced in a dose-dependent fashion in all three genotypes (P < .05). However, predose and postdose ALDO and A-II levels did not differ between each genotype subgroup at baseline or by enalapril dose within each genotype subgroup. ALDO escape and A-II reactivation were not affected by ACE genotype or enalapril dosage. Predose sACE were consistently higher in the DD genotype when compared with ID or II subgroups. Despite a dose-dependent suppression of sACE, there were no observed statistically significant differences in ALDO and A-II suppression or escape with escalating doses of enalapril within each subgroup.

  10. Safety and pharmacokinetics of the oral iron chelator SP-420 in β-thalassemia.

    PubMed

    Taher, Ali T; Saliba, Antoine N; Kuo, Kevin H; Giardina, Patricia J; Cohen, Alan R; Neufeld, Ellis J; Aydinok, Yesim; Kwiatkowski, Janet L; Jeglinski, Brenda I; Pietropaolo, Keith; Berk, Gregory; Viprakasit, Vip

    2017-12-01

    Our phase I, open-label, multi-center, dose-escalation study evaluated the pharmacokinetics (PK) of SP-420, a tridentate oral iron chelating agent of the desferrithiocin class, in patients with transfusion dependent β-thalassemia. SP-420 was administered as a single dose of 1.5 (n = 3), 3 (n = 3), 6 (n = 3), 12 (n = 3), and 24 (n = 6) mg/kg or as a twice-daily dose of 9 mg/kg (n = 6) over 14-28 days. There was a near dose-linear increase in the mean plasma SP-420 concentrations and in the mean values for C max and AUC 0-τ over the dose range evaluated. The median t max ranged from 0.5 to 2.25 h and was not dose dependent. The study was prematurely terminated by the sponsor due to renal adverse events (AE) including proteinuria, increase in serum creatinine, and one case of Fanconi syndrome. Other adverse effects included hypersensitivity reactions and gastrointestinal disturbances. Based on current dose administration, the renal AE observed outweighed the possible benefits from chelation therapy. However, additional studies assessing efficacy and safety of lower doses or less frequent dosing of SP-420 over longer durations with close monitoring would be necessary to better explain the findings of our study and characterize the safety of the study drug. © 2017 Wiley Periodicals, Inc.

  11. Dose- and time-dependent activation of rat alveolar macrophages by glucocorticoids

    PubMed Central

    BROUG-HOLUB, E; KRAAL, G

    1996-01-01

    Effects of glucocorticoids on immune functions are generally thought to be suppressive and anti-inflammatory. However, most reports dealing with this issue describe effects of long-term treatment with high doses of glucocorticoids on immune functions. In the present study we have investigated both dose and timing effects of exposure of alveolar macrophages with dexamethasone on lipopolysaccharide (LPS)-induced IL-1β and nitric oxide secretion. For this purpose, alveolar macrophages were preincubated with various doses of dexamethasone during varying intervals, followed by stimulation of the cells with endotoxin, either in the absence or presence of dexamethasone. Subsequently, the effects of this treatment on IL-1β and nitric oxide secretion were measured. It was shown that both short-term incubation of alveolar macrophages with high doses of dexamethasone and long-term incubation with low doses of dexamethasone lead to enhanced nitric oxide and enhanced IL-1β secretion upon subsequent stimulation of the cells with LPS. In contrast, long-term incubation of alveolar macrophages with high-dose dexamethasone leads to decreased IL-1β and nitric oxide secretion upon subsequent stimulation. Thus, it is concluded that the effects of dexamethasone on rat alveolar macrophages are both time- and dose-dependent. It is therefore argued that effects of glucocorticoids on immune functions are not a priori suppressive, but that both dose and timing effects should be taken into account. PMID:8625529

  12. Effectiveness of low-dose naltrexone in the post-detoxification treatment of opioid dependence.

    PubMed

    Mannelli, Paolo; Patkar, Ashwin A; Peindl, Kathleen; Murray, Heather W; Wu, Li-Tzy; Hubbard, Robert

    2007-10-01

    The clinical use of naltrexone (NTX) in the treatment of opioid dependence has been limited because of poor compliance and inconsistent outcomes. In particular, the therapeutic benefit of extended treatment with NTX after opioid detoxification is unclear. The present study evaluated whether the augmentation with low-dose NTX during the post-detoxification treatment of opioid dependence would improve outcomes. In an open-label naturalistic design, 435 opioid-dependent patients who had completed inpatient detoxification were offered the choice of entering 1 of the 2 outpatient treatment arms: clonidine extended treatment (CET) (clonidine + psychosocial treatment), or enhanced extended treatment (EET) (oral NTX [1-10 mg/d] + CET) for 21 days. The primary outcome measure was retention in treatment. Secondary outcomes included abstinence from opioids, dropouts, and adherence to postdischarge care. One hundred sixty-two patients (37.2%) accepted EET. Subjects receiving EET stayed longer in the program (F = 64.4; P = 0.000), were less likely to drop out, used less opioids, and followed through with referral to long-term outpatient treatment in a higher number, compared with patients in the CET arm (P = 0.000 in each case). The NTX + clonidine combination was safe and well tolerated. This preliminary study indicates the potential benefit of augmentation with low-dose NTX to improve outcomes after opioid detoxification for a preferred group of patients. Randomized controlled trials are necessary to further evaluate the role of low-dose NTX in the outpatient treatment of opioid dependence.

  13. Effect of bucladesine, pentoxifylline, and H-89 as cyclic adenosine monophosphate analog, phosphodiesterase, and protein kinase A inhibitor on acute pain.

    PubMed

    Salehi, Forouz; Hosseini-Zare, Mahshid S; Aghajani, Haleh; Seyedi, Seyedeh Yalda; Hosseini-Zare, Maryam S; Sharifzadeh, Mohammad

    2017-08-01

    The aim of this study was to determine the effects of cyclic adenosine monophosphate (cAMP) and its dependent pathway on thermal nociception in a mouse model of acute pain. Here, we studied the effect of H-89 (protein kinase A inhibitor), bucladesine (Db-cAMP) (membrane-permeable analog of cAMP), and pentoxifylline (PTX; nonspecific phosphodiesterase (PDE) inhibitor) on pain sensation. Different doses of H-89 (0.05, 0.1, and 0.5 mg/100 g), PTX (5, 10, and 20 mg/100 g), and Db-cAMP (50, 100, and 300 nm/mouse) were administered intraperitoneally (I.p.) 15 min before a tail-flick test. In combination groups, we injected the first and the second compounds 30 and 15 min before the tail-flick test, respectively. I.p. administration of H-89 and PTX significantly decreased the thermal-induced pain sensation in their low applied doses. Db-cAMP, however, decreased the pain sensation in a dose-dependent manner. The highest applied dose of H-89 (0.5 mg/100 g) attenuated the antinociceptive effect of Db-cAMP in doses of 50 and 100 nm/mouse. Surprisingly, Db-cAMP decreased the antinociceptive effect of the lowest dose of H-89 (0.05 mg/100 g). All applied doses of PTX reduced the effect of 0.05 mg/100 g H-89 on pain sensation; however, the highest dose of H-89 compromised the antinociceptive effect of 20 mg/100 g dose of PTX. Co-administration of Db-cAMP and PTX increased the antinociceptive effect of each compound on thermal-induced pain. In conclusion, PTX, H-89, and Db-cAMP affect the thermal-induced pain by probably interacting with intracellular cAMP and cGMP signaling pathways and cyclic nucleotide-dependent protein kinases. © 2017 Société Française de Pharmacologie et de Thérapeutique.

  14. Somapacitan, a once-weekly reversible albumin-binding GH derivative, in children with GH deficiency: A randomized dose-escalation trial.

    PubMed

    Battelino, Tadej; Rasmussen, Michael Højby; De Schepper, Jean; Zuckerman-Levin, Nehama; Gucev, Zoran; Sävendahl, Lars

    2017-10-01

    To evaluate the safety, local tolerability, pharmacodynamics and pharmacokinetics of escalating single doses of once-weekly somapacitan, a reversible, albumin-binding GH derivative, vs once-daily GH in children with GH deficiency (GHD). Phase 1, randomized, open-label, active-controlled, dose-escalation trial (NCT01973244). Thirty-two prepubertal GH-treated children with GHD were sequentially randomized 3:1 within each of four cohorts to a single dose of somapacitan (0.02, 0.04, 0.08 and 0.16 mg/kg; n=6 each), or once-daily Norditropin ® SimpleXx ® (0.03 mg/kg; n=2 each) for 7 days. Pharmacokinetic and pharmacodynamic profiles were assessed. Adverse events were all mild, and there were no apparent treatment-dependent patterns in type or frequency. Four mild transient injection site reactions were reported in three of 24 children treated with somapacitan. No antisomapacitan/anti-human growth hormone (hGH) antibodies were detected. Mean serum concentrations of somapacitan increased in a dose-dependent but nonlinear manner: maximum concentration ranged from 21.8 ng/mL (0.02 mg/kg dose) to 458.4 ng/mL (0.16 mg/kg dose). IGF-I and IGFBP-3, and change from baseline in IGF-I standard deviation score (SDS) and IGFBP-3 SDS, increased dose dependently; greatest changes in SDS values were seen for 0.16 mg/kg. IGF-I SDS values were between -2 and +2 SDS, except for peak IGF-I SDS with 0.08 mg/kg somapacitan. Postdosing, IGF-I SDS remained above baseline levels for at least 1 week. Single doses of once-weekly somapacitan (0.02-0.16 mg/kg) were well tolerated in children with GHD, with IGF-I profiles supporting a once-weekly treatment profile. No clinically significant safety/tolerability signals or immunogenicity concerns were identified. © 2017 The Authors. Clinical Endocrinology Published by John Wiley & Sons Ltd.

  15. A Phase I Study of the Cyclin-Dependent Kinase 4/6 Inhibitor Ribociclib (LEE011) in Patients with Advanced Solid Tumors and Lymphomas.

    PubMed

    Infante, Jeffrey R; Cassier, Philippe A; Gerecitano, John F; Witteveen, Petronella O; Chugh, Rashmi; Ribrag, Vincent; Chakraborty, Abhijit; Matano, Alessandro; Dobson, Jason R; Crystal, Adam S; Parasuraman, Sudha; Shapiro, Geoffrey I

    2016-12-01

    Ribociclib (an oral, highly specific cyclin-dependent kinase 4/6 inhibitor) inhibits tumor growth in preclinical models with intact retinoblastoma protein (Rb + ). This first-in-human study investigated the MTD, recommended dose for expansion (RDE), safety, preliminary activity, pharmacokinetics, and pharmacodynamics of ribociclib in patients with Rb + advanced solid tumors or lymphomas. Patients received escalating doses of ribociclib (3-weeks-on/1-week-off or continuous). Dose escalation was guided by a Bayesian Logistic Regression Model with overdose control principle. Among 132 patients, 125 received ribociclib 3-weeks-on/1-week-off and 7 were dosed continuously. Nine dose-limiting toxicities were observed among 70 MTD/RDE evaluable patients during cycle 1, most commonly neutropenia (n = 3) and thrombocytopenia (n = 2). The MTD and RDE were established as 900 and 600 mg/day 3-weeks-on/1-week-off, respectively. Common treatment-related adverse events were (all-grade; grade 3/4) neutropenia (46%; 27%), leukopenia (43%; 17%), fatigue (45%; 2%), and nausea (42%; 2%). Asymptomatic Fridericia's corrected QT prolongation was specific to doses ≥600 mg/day (9% of patients at 600 mg/day; 33% at doses >600 mg/day). Plasma exposure increases were slightly higher than dose proportional; mean half-life at the RDE was 32.6 hours. Reduced Ki67 was observed in paired skin and tumor biopsies, consistent with ribociclib-mediated antiproliferative activity. There were 3 partial responses and 43 patients achieved a best response of stable disease; 8 patients were progression-free for >6 months. Ribociclib demonstrated an acceptable safety profile, dose-dependent plasma exposure, and preliminary signs of clinical activity. Phase I-III studies of ribociclib are under way in various indications. Clin Cancer Res; 22(23); 5696-705. ©2016 AACR. ©2016 American Association for Cancer Research.

  16. TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowik, P; Bujila, R; Merzan, D

    2015-06-15

    Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CTmore » dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.« less

  17. Safety and immunogenicity of adenovirus-vectored near-consensus HIV type 1 clade B gag vaccines in healthy adults.

    PubMed

    Harro, Clayton D; Robertson, Michael N; Lally, Michelle A; O'Neill, Lori D; Edupuganti, Srilatha; Goepfert, Paul A; Mulligan, Mark J; Priddy, Frances H; Dubey, Sheri A; Kierstead, Lisa S; Sun, Xiao; Casimiro, Danilo R; DiNubile, Mark J; Shiver, John W; Leavitt, Randi Y; Mehrotra, Devan V

    2009-01-01

    Vaccines inducing pathogen-specific cell-mediated immunity are being developed using attenuated adenoviral (Ad) vectors. We report the results of two independent Phase I trials of similar replication-deficient Ad5 vaccines containing a near-consensus HIV-1 clade B gag transgene. Healthy HIV-uninfected adults were enrolled in two separate, multicenter, dose-escalating, blinded, placebo-controlled studies to assess the safety and immunogenicity of a three-dose homologous regimen of Ad5 and MRKAd5 HIV-1 gag vaccines given on day 1, week 4, and week 26. Adverse events were collected for 29 days following each intradeltoid injection. The primary immunogenicity endpoint was the proportion of subjects with a positive unfractionated Gag-specific IFN-gamma ELISPOT response measured 4 weeks after the last dose (week 30). Analyses were performed after combining data for each dose group from both protocols, stratifying by baseline Ad5 titers. Overall, 252 subjects were randomized to receive either vaccine or placebo, including 229 subjects (91%) who completed the study through week 30. Tolerability and immunogenicity did not appear to differ between the Ad5 and MRKAd5 vaccines. The frequency of injection-site reactions was dose dependent. Systemic adverse events were also dose dependent and more frequent in subjects with baseline Ad5 titers <200 versus > or =200, especially after the first dose. The percent of ELISPOT responders and the ELISPOT geometric means overall were significantly higher for all four vaccine doses studied compared to placebo, and were generally higher in vaccine recipients with baseline Ad5 titers <200 versus > or = 200. Ad5 titers increased after vaccination in a dose-dependent fashion. Both Ad5-vectored HIV-1 vaccines were generally well tolerated and induced cell-mediated immune responses against HIV Gag-peptides in the majority of healthy adults with baseline Ad5 titers <200. Preexistent and/or vaccine-induced immunity to the Ad5 vector may dampen the CMI response to HIV Gag.

  18. Safety and Immunogenicity of Adenovirus-Vectored Near-Consensus HIV Type 1 Clade B gag Vaccines in Healthy Adults

    PubMed Central

    Robertson, Michael N.; Lally, Michelle A.; O'Neill, Lori D.; Edupuganti, Srilatha; Goepfert, Paul A.; Mulligan, Mark J.; Priddy, Frances H.; Dubey, Sheri A.; Kierstead, Lisa S.; Sun, Xiao; Casimiro, Danilo R.; DiNubile, Mark J.; Shiver, John W.; Leavitt, Randi Y.; Mehrotra, Devan V.

    2009-01-01

    Abstract Vaccines inducing pathogen-specific cell-mediated immunity are being developed using attenuated adenoviral (Ad) vectors. We report the results of two independent Phase I trials of similar replication-deficient Ad5 vaccines containing a near-consensus HIV-1 clade B gag transgene. Healthy HIV-uninfected adults were enrolled in two separate, multicenter, dose-escalating, blinded, placebo-controlled studies to assess the safety and immunogenicity of a three-dose homologous regimen of Ad5 and MRKAd5 HIV-1 gag vaccines given on day 1, week 4, and week 26. Adverse events were collected for 29 days following each intradeltoid injection. The primary immunogenicity endpoint was the proportion of subjects with a positive unfractionated Gag-specific IFN-γ ELISPOT response measured 4 weeks after the last dose (week 30). Analyses were performed after combining data for each dose group from both protocols, stratifying by baseline Ad5 titers. Overall, 252 subjects were randomized to receive either vaccine or placebo, including 229 subjects (91%) who completed the study through week 30. Tolerability and immunogenicity did not appear to differ between the Ad5 and MRKAd5 vaccines. The frequency of injection-site reactions was dose dependent. Systemic adverse events were also dose dependent and more frequent in subjects with baseline Ad5 titers <200 versus ≥200, especially after the first dose. The percent of ELISPOT responders and the ELISPOT geometric means overall were significantly higher for all four vaccine doses studied compared to placebo, and were generally higher in vaccine recipients with baseline Ad5 titers <200 versus ≥200. Ad5 titers increased after vaccination in a dose-dependent fashion. Both Ad5-vectored HIV-1 vaccines were generally well tolerated and induced cell-mediated immune responses against HIV Gag-peptides in the majority of healthy adults with baseline Ad5 titers <200. Preexistent and/or vaccine-induced immunity to the Ad5 vector may dampen the CMI response to HIV Gag. PMID:19108693

  19. Treatment of Narcolepsy with Methamphetamine

    PubMed Central

    Miller, Merrill M.; Hajdukovic, Roza; Erman, Milton K.

    2008-01-01

    Summary Eight pairs of subjects (each consisting of a narcoleptic and a control matched on the basis of age, sex, educational background and job) were evaluated under the following double-blind, randomized treatment conditions: baseline, placebo, low dose and high dose methamphetamine. Subjects were drug-free for 2 weeks prior to beginning the protocol. Methamphetamine was the only drug taken during the protocol and was given in a single morning dose of 0, 20 or 40–60 mg to narcoleptics and 0, 5 or 10 mg to controls. The protocol was 28 days long, with each of the four treatment conditions lasting 4 days followed by 3 days of washout. Nighttime polysomnography and daytime testing were done during the last 24 hours of each treatment condition. Daytime sleep tendency was assessed with the multiple sleep latency test (MSLT). Daytime performance was assessed with performance tests including a simple, computer-based driving task. Narcoleptics’ mean MSLT sleep latency increased from 4.3 minutes on placebo to 9.3 minutes on high dose, compared with an increase from 10.4 to 17.1 minutes for controls. Narcoleptics’ error rate on the driving task decreased from 2.53% on placebo to 0.33% on high dose, compared with a decrease from 0.22% to 0.16% for controls. The effects of methamphetamine on nocturnal sleep were generally dose-dependent and affected sleep continuity and rapid eye movement (REM) sleep. Elimination half life was estimated to be between 15.9 and 22.0 hours. Mild side effects emerged in a dose-dependent fashion and most often involved the central nervous system and gastrointestinal tract. We concluded that methamphetamine caused a dose-dependent decrease in daytime sleep tendency and improvement in performance in both narcoleptics and controls. Methamphetamine at doses of 40–60 mg allowed narcoleptics to function at levels comparable to those of unmedicated controls. PMID:8341891

  20. Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams.

    PubMed

    Mandapaka, A K; Ghebremedhin, A; Patyal, B; Marinelli, Marco; Prestopino, G; Verona, C; Verona-Rinati, G

    2013-12-01

    To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams. The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up∕stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated. A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy∕min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters. The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.

Top